  1. Modacrylic anion-exchange fibers for Cr(VI) removal from chromium-plating rinse water in batch and flow-through column experiments.

    Science.gov (United States)

    Lee, Seung-Chan; Kang, Jin-Kyu; Sim, Eun-Hye; Choi, Nag-Choul; Kim, Song-Bae

    2017-11-10

    The aim of this study was to investigate Cr(VI) removal from chromium-plating rinse water using modacrylic anion-exchange fibers (KaracaronTM KC31). Batch experiments were performed with synthetic Cr(VI) solutions to characterize the KC31 fibers in Cr(VI) removal. Cr(VI) removal by the fibers was affected by solution pH; the Cr(VI) removal capacity was the highest at pH 2 and decreased gradually with a pH increase from 2 to 12. In regeneration and reuse experiments, the Cr(VI) removal capacity remained above 37.0 mg g -1 over five adsorption-desorption cycles, demonstrating that the fibers could be successfully regenerated with NaCl solution and reused. The maximum Cr(VI) removal capacity was determined to be 250.3 mg g -1 from the Langmuir model. In Fourier-transform infrared spectra, a Cr = O peak newly appeared at 897 cm -1 after Cr(VI) removal, whereas a Cr-O peak was detected at 772 cm -1 due to the association of Cr(VI) ions with ion-exchange sites. X-ray photoelectron spectroscopy analyses demonstrated that Cr(VI) was partially reduced to Cr(III) after the ion exchange on the surfaces of the fibers. Batch experiments with chromium-plating rinse water (Cr(VI) concentration = 1178.8 mg L -1 ) showed that the fibers had a Cr(VI) removal capacity of 28.1-186.4 mg g -1 under the given conditions (fiber dose = 1-10 g L -1 ). Column experiments (column length = 10 cm, inner diameter = 2.5 cm) were conducted to examine Cr(VI) removal from chromium-plating rinse water by the fibers under flow-through column conditions. The Cr(VI) removal capacities for the fibers at flow rates of 0.5 and 1.0 mL min -1 were 214.8 and 171.5 mg g -1 , respectively. This study demonstrates that KC31 fibers are effective in the removal of Cr(VI) ions from chromium-plating rinse water.

  2. Optimal design of zero-water discharge rinsing systems.

    Science.gov (United States)

    Thöming, Jorg

    2002-03-01

    This paper is about zero liquid discharge in processes that use water for rinsing. Emphasis was given to those systems that contaminate process water with valuable process liquor and compounds. The approach involved the synthesis of optimal rinsing and recycling networks (RRN) that had a priori excluded water discharge. The total annualized costs of the RRN were minimized by the use of a mixed-integer nonlinear program (MINLP). This MINLP was based on a hyperstructure of the RRN and contained eight counterflow rinsing stages and three regenerator units: electrodialysis, reverse osmosis, and ion exchange columns. A "large-scale nickel plating process" case study showed that by means of zero-water discharge and optimized rinsing the total waste could be reduced by 90.4% at a revenue of $448,000/yr. Furthermore, with the optimized RRN, the rinsing performance can be improved significantly at a low-cost increase. In all the cases, the amount of valuable compounds reclaimed was above 99%.

  3. Electrochemical reactor with rotating cylinder electrode for optimum electrochemical recovery of nickel from plating rinsing effluents

    Energy Technology Data Exchange (ETDEWEB)

    Hernández-Tapia, J.R.; Vazquez-Arenas, J., E-mail: jgva@xanum.uam.mx; González, I.

    2013-11-15

    Highlights: • Rotating cylinder cathode enhanced mass transport rates of Ni(II) species. • pH control around 4 is crucial to recover high purity nickel. • Increasing cathodic currents increased energy consumptions for nickel recovery. • Specific energy consumptions increase drastically at the end of electrolysis. -- Abstract: This study is devoted to analyze the metallic electrochemical recovery of nickel from synthetic solutions simulating plating rinsing discharges, in order to meet the water recycling policies implemented in these industries. These effluents present dilute Ni(II) concentrations (100 and 200 ppm) in chloride and sulfate media without supporting electrolyte (397–4202 μS cm{sup −1}), which stems poor current distribution, limited mass transfer, ohmic drops and enhancement of parasitic reactions. An electrochemical reactor with rotating cylinder electrode (RCE) and a pH controller were utilized to overcome these problems. The pH control around 4 was crucial to yield high purity nickel, and thus prevent the precipitation of hydroxides and oxides. Macroelectrolysis experiments were systematically conducted to analyze the impacts of the applied current density in the recovery efficiency and energy consumption, particularly for very diluted effluents (100 and 200 ppm Ni(II)), which present major recovery problems. Promising nickel recoveries in the order of 90% were found in the former baths using a current density of −3.08 mA cm{sup −2}, and with overall profits of 9.64 and 14.69 USD kg{sup −1}, respectively. These estimations were based on the international market price for nickel ($18 USD kg{sup −1})

  4. Removal of nickel from electroplating rinse waters using electrostatic shielding electrodialysis/electrodeionization.

    Science.gov (United States)

    Dermentzis, Konstantinos

    2010-01-15

    Electrostatic shielding zones made of electrode graphite powder were used as a new type of ionic and electronic current sinks. Because of the local elimination of the applied electric field, voltage and current within the zones, ions are led inside them and accumulate there. The current sinks were implemented in electrostatic shielding electrodialysis of a simulated nickel plating rinse water containing 100 mg L(-1) nickel and electrodeionization of a 0.001 M NiSO(4) solution with simultaneous electrochemical regeneration of the ion exchange resin beds. Pure water was obtained with a Ni(2+) ion concentration of less than 0.1 mg L(-1) at a flow rate of 2.02 x 10(-4)dm(3)s(-1) diluate stream and a current density of 30 Am(-2).

  5. RECYCLING NICKEL ELECTROPLATING RINSE WATERS BY LOW TEMPERATURE EVAPORATION AND REVERSE OSMOSIS

    Science.gov (United States)

    Low temperature evaporation and reverse osmosis systems were each evaluated (on a pilot scale) on their respective ability to process rinse water collected from a nickel electroplating operation. Each system offered advantages under specific operating conditions. The low temperat...

  6. Viability of sublethally injured coliform bacteria on fresh-cut cabbage stored in high CO2 atmospheres following rinsing with electrolyzed water.

    Science.gov (United States)

    Izumi, Hidemi; Inoue, Ayano

    2018-02-02

    The extent of sublethally injured coliform bacteria on shredded cabbage, either rinsed or not rinsed with electrolyzed water, was evaluated during storage in air and high CO 2 controlled atmospheres (5%, 10%, and 15%) at 5°C and 10°C using the thin agar layer (TAL) method. Sublethally injured coliform bacteria on nonrinsed shredded cabbage were either absent or they were injured at a 64-65% level when present. Rinsing of shredded cabbage with electrolyzed water containing 25ppm available chlorine reduced the coliform counts by 0.4 to 1.1 log and caused sublethal injury ranging from 42 to 77%. Pantoea ananatis was one of the species injured by chlorine stress. When shredded cabbage, nonrinsed or rinsed with electrolyzed water, was stored in air and high CO 2 atmospheres at 5°C for 7days and 10°C for 5days, coliform counts on TAL plates increased from 3.3-4.5 to 6.5-9.0 log CFU/g during storage, with the increase being greater at 10°C than at 5°C. High CO 2 of 10% and 15% reduced the bacterial growth on shredded cabbage during storage at 5°C. Although injured coliform bacteria were not found on nonrinsed shredded cabbage on the initial day, injured coliforms at a range of 49-84% were detected on samples stored in air and high CO 2 atmospheres at 5°C and 10°C. Injured cells were detected more frequently during storage at both temperatures irrespective of the CO 2 atmosphere when shredded cabbage was rinsed with electrolyzed water. These results indicated that injured coliform bacteria on shredded cabbage, either rinsed or not rinsed with electrolyzed water, exhibited different degrees of injury during storage regardless of the CO 2 atmosphere and temperature tested. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Prebrushing rinse with water on plaque removal: a split-mouth design.

    Science.gov (United States)

    Van der Sluijs, E; Slot, D E; Hennequin-Hoenderdos, N L; Van Leeuwen, Mpc; Van der Weijden, G A

    2017-11-01

    The aim was to evaluate whether there is an additional beneficial effect on dental plaque removal of rinsing the oral cavity with water before toothbrushing. In total, 48 non-dental, systemically healthy participants ≥18 years were included in this randomized controlled clinical trial using a split-mouth design. The participants were requested to refrain from any form of oral hygiene for 48 h. First dental plaque scores (PI) were assessed full mouth. Two randomly assigned contra-lateral quadrants were brushed. Next the participant rinsed for 1 min with 15 ml water. Subsequently, the opposite two contra-lateral quadrants were brushed. Brushing was performed without toothpaste. Subsequently the second full-mouth PI assessment was performed. The brushing and rinsing procedure was performed under supervision and brushing time was tracked by a timer, each quadrant was brushed for 30 s. For the buccal, lingual, and approximal surfaces and tooth type, a subanalysis was performed. At baseline there was no statistically significantly difference between the two sets of contra-lateral quadrants. When a water rinse was used before toothbrushing the PI-score was reduced by 58%. If water rinse was used post-brushing the PI-score reduced by 57%. The difference of 0.04 in mean plaque index score reduction between the two brushing regimens was not significant(P = 0.162). When a 2 min brushing exercise was performed, on average more than 55% dental plaque was removed. Prerinsing with water did not contribute significantly to toothbrush efficacy. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Ion exchange treatment of rinse water generated in the galvanizing process.

    Science.gov (United States)

    Marañón, Elena; Fernández, Yolanda; Castrillón, Leonor

    2005-01-01

    A study was conducted of the viability of using the cationic exchange resins Amberlite IR-120 and Lewatit SP-112 to treat rinse water generated in the galvanizing process as well as acidic wastewater containing zinc (Zn) and iron (Fe). Solutions containing either 100 mg/L of Zn at pH 5.6 (rinse water) or Fe and Zn at concentrations of 320 and 200 mg/L at pH 1.5 (acidic water), respectively, were percolated through packed beds until the resins were exhausted. Breakthrough capacities obtained ranged between 1.1 and 1.5 meq metal/mL resin. The elution of metal and the regeneration of resins were performed with hydrochloric acid. The influence of the flowrate used during the loading stage was also studied, with 0.5 bed volumes/min (3.2 cm/min) found to be the optimum flowrate.

  9. The relationship between turbidity of mouth-rinsed water and oral health status.

    Science.gov (United States)

    Takeuchi, Susumu; Ueno, Masayuki; Takehara, Sachiko; Pham, Thuy Anh Vu; Hakuta, Chiyoko; Morishima, Seiji; Shinada, Kayoko; Kawaguchi, Yoko

    2013-01-01

    The purpose of this study was to examine the relationship between turbidity of mouth rinsed water and oral health status such as dental and periodontal conditions, oral hygiene status, flow rate of saliva and oral bacteria. Subjects were 165 patients who visited the Dental Hospital, Tokyo Medical and Dental University. Oral health status, including dental and periodontal conditions, oral hygiene status and flow rate of saliva, was clinically examined. The turbidity was measured with a turbidimeter. Quantification of Fusobacterium spp, Porphyromonas gingivalis, Tannerella forsythia, Treponema denticola and total bacteria levels was performed using real-time PCR. The Pearson correlation and multiple regression analysis were used to explore the associations between the turbidity and oral health parameters. The turbidity showed significant correlations with the number of decayed teeth and deep pockets, the plaque index, extent of tongue coating and Fusobacterium spp, P. gingivalis, T. forsythia, T. denticola and total bacteria levels. In a multiple regression model, the turbidity was negatively associated with the flow rate of saliva and positively associated with the total number of bacteria (p turbidity of mouth rinsed water could be used as an indicator to evaluate oral health condition and the amount of bacteria in the oral cavity. In addition, the turbiditimeter appeared as a simple and objective device for screening abnormality of oral health condition at chair side as well as community-based research.

  10. Mouth Rinses

    Science.gov (United States)

    ... with more severe oral problems, such as cavities, periodontal disease, gum inflammation, and xerostomia (dry mouth). Therapeutic ... fight up to 50 percent more of the bacteria that cause cavities, and most rinses are effective ...

  11. Tomato type and post-treatment water rinse affect efficacy of acid washes against Salmonella enterica inoculated on stem scars of tomatoes and product quality.

    Science.gov (United States)

    Fan, Xuetong; Gurtler, Joshua B; Sokorai, Kimberly J B

    2018-09-02

    A study was conducted to evaluate the effects of post-treatment rinsing with water on the inactivation efficacy of acid treatments against Salmonella inoculated onto stem scar areas of two types of tomatoes. In addition, impact on fruit quality was investigated during 21 days post-treatment storage at 10 °C. A four-strain cocktail of Salmonella enterica (S. Montevideo, S. Newport, S. Saintpaul, and S. Typhimurium) was inoculated onto stem scar areas of grape and large round tomatoes. The inoculated fruits were then treated for 2 min with the following solutions: water, 2% lactic acid +2% acetic acid +2% levulinic acid, 1.7% lactic acid +1.7% acetic acid +1.7% levulinic acid, and 3% lactic acid +3% acetic acid. After treatments, half of the fruits were rinsed with water while another half were not rinsed. Non-inoculated grape tomatoes for quality analysis were treated with the same solutions with and without subsequent water rinse. Results demonstrated that the acid combinations reduced populations of Salmonella enterica on the stem scar area of grape tomatoes by 1.52-1.90 log CFU/fruit, compared with the non-treated control while water wash and rinse removed the bacterium by only 0.23-0.30 log CFU/fruit. On the stem scar of large round tomatoes, the same acid treatments achieved 3.54 log CFU/fruit reduction of the pathogen. The varying response to the acid washes between grape and large round tomatoes seems to be related to the differences in surface characteristics of stem scar areas observed with SEM. Rinsing with water after acid combination treatments did not significantly affect the efficacy of the treatments in either grape or large round tomatoes. Acidic off-odor was detected on fruits treated with acid combination without water rinse 1 day after treatment while water rinse eliminated the off-odor. The acid treatments with and without water rinse did not consistently affect appearance, color, firmness, or lycopene or ascorbic acid contents of

  12. Method of nickel-plating large components

    International Nuclear Information System (INIS)

    Wilbuer, K.

    1997-01-01

    The invention concerns a method of nickel-plating components, according to which even large components can be provided with an adequate layer of nickel which is pore- and stress-free and such that water is not lost. According to the invention, the component is heated and, after heating, is pickled, rinsed, scoured, plated in an electrolysis process, and rinsed again. (author)

  13. The use of a rotating cylinder electrode to recover zinc from rinse water generated by the electroplating industry.

    Science.gov (United States)

    Matlalcuatzi, Sairi; Nava, José L

    2012-01-01

    This work concerns the application of a laboratory scale rotating cylinder electrode (RCE) to recover zinc from rinse water generated by the electrolytic zinc process (initially 1,300, 4,400, 50, 20 mg L(-1) of Zn(II), Fe(III), Ag(I) and Cr(VI), respectively, at pH 2), although it is also applicable to other electroplating industries. Experimental results demonstrated the convenience of the removal of ferric ions, as (Fe(OH)(3(s))) by a pH adjustment to 4, before zinc electro recovery on the RCE. The generation of smooth zinc deposits on the RCE was obtained at Reynolds numbers within the range of 15,000 ≤ Re ≤ 124,000 and limiting current densities (J(L)) in the interval of -4.8 to -13 mA cm(-2). The zinc recovery reached a conversion of 67% in 90 min of electrolysis for Re = 124,000 and J = -13 mA cm(-2), 21% current efficiency, and energy consumption of 9.5 kWh m(-3). The treated solution can be recycled back through the same rinsing process.

  14. Microbiological Evaluation of Broiler Carcasses, Wash and Rinse Water from Pluck Shops (Cottage Poultry Processors in the County Nariva/Mayaro, Trinidad, Trinidad and Tobago, West Indies

    Directory of Open Access Journals (Sweden)

    Thomas, A.

    2006-01-01

    Full Text Available A study on the prevalence and levels of Campylobacter, Salmonella and E. coli on broiler chicken carcasses, wash and rinse water from pluck shops/ cottage poultry processors (CPP in county Nariva Mayaro Trinidad was done. There are 21 pluck shops/ cottage poultry processors in the county, 14 pluck shops were randomly selected for the study. Samples consisted of 28 broiler carcasses, 14 wash water samples and 14 rinse water samples. Over all the isolation rate of Campylobacter, Salmonella and E. coli from broiler carcasses wash and rinse water showed significant differences (P< 0.05 between pluck shops. Of the 56 samples examined from the 14 pluck shops sampled, 34 (60.7% were positive for Campylobacter, 34 (60.7% for Salmonella and 40 (71.4% for E. coli. The correlation between the levels of Campylobacter found on carcasses and in wash water (r2= 0.657 and rinse water (r2= 0.600 was significant (P< 0.05 among pluck shops/CPP. There was also a high correlation (P< 0.05 between wash and rinse water samples (r2= 0.950 for Campylobacter. Salmonella levels on carcasses and in wash water were positively (P< 0.05 correlated (r2= 0.947. Of the 14 pluck shops examined 6 (42.9% had Campylobacter levels that corresponded to infectious dose in humans. The infectious doses for Salmonella were isolated from 3 (21.4% pluck shops and 13 (92.9% pluck shops evaluated had E. coli present at potentially infectious levels. Three pluck shops/CPP (21.4% had infectious dose for Campylobacter, Salmonella and E. coli where as all others had infectious levels for one or two pathogens. It was concluded that these pathogens are present in pluck shops/CPP in the county, having levels considered to be potentially infectious to humans and as such there should be health concern.

  15. Re-use of laundry rinsing water by low cost adsorption technology

    NARCIS (Netherlands)

    Schouten, N.

    2009-01-01

    Shortage of water is a growing global problem. One way of dealing with this problem is the development of technologies for wastewater clean-up and re-use. Laundry accounts often for more than half of the daily domestic water consumption in countries like India. The major part of laundry water is

  16. Daylong Effect of Rinsing with Water Diluted Antiplaque®Toothpaste Combined with Toothbrushing on Volatile Sulphur Compound Levels

    Directory of Open Access Journals (Sweden)

    Anandina Irmagita

    2013-07-01

    Full Text Available Halitosis, complained by most adult population, is a common oral condition. About 8%% of the cases happened because of the microbia activity in the oral cavity that produces Volatile Sulphur Compound (VSC which has unpleasant odour. Daily oral prophylaxis can reduce the oral VSC levels. Objective: to determine the daylong effect of Antiplque® toothpaste in daily oral prophylaxis: as dentrifice for tooth brushing and, in modified way, as oral rinse; on the VSC level. Methods: a double blind, clinical experimental study, involving 120 subjects with or without halitosis complain, divided in 2 treatment groups (oral rinse group and the combination of tooth brushing and oral rinse group, using Antiplaque® toothpaste and 2 control groups (same procedure using placebo toothpaste. The daylong VSC levels measure with halimeter were taken twice, in the afternoon day I and day II. Results: there are significant reduction of daylong VSC levels (Wilcoxon signed rank test P<0.0%, but not in the treatment groups using the placebo toothpaste. The result on conbination of tooth brushing and oral rinse using Antiplaque® toothpaste are significant compared to the oral rinse treatment using Antiplaque® toothpaste alone (Mann Whitney, P<0.05. Conclusion: tooth brushing with Antiplaque® toothpaste combined with oral rinse using the modified Antiplaque® toothpaste can significantly reduce daylong VSC levels.DOI: 10.14693/jdi.v16i2.94

  17. Comparative evaluation of mouth rinsing with plain water and an antibacterial mouth rinse on salivary pH: A randomized clinical trial

    OpenAIRE

    Shweta Singh; P Anuradha; S Sahana; Manu Narayan; Sugandha Agarwal

    2017-01-01

    Introduction: Salivary pH plays an important role in maintaining oral health and in particular affecting dental caries. Studies have confirmed the antibacterial beneficial effects of chlorhexidine on dental health by increasing salivary pH (changing acidic pH to more neutral pH). Water, the most precious/omnipresent liquid also bears an effect on salivary pH. Materials and Methods: A double-blind concurrent parallel study design was employed on 40 individuals to evaluate changes in salivary p...

  18. Handwashing and Ebola virus disease outbreaks: A randomized comparison of soap, hand sanitizer, and 0.05% chlorine solutions on the inactivation and removal of model organisms Phi6 and E. coli from hands and persistence in rinse water.

    Science.gov (United States)

    Wolfe, Marlene K; Gallandat, Karin; Daniels, Kyle; Desmarais, Anne Marie; Scheinman, Pamela; Lantagne, Daniele

    2017-01-01

    To prevent Ebola transmission, frequent handwashing is recommended in Ebola Treatment Units and communities. However, little is known about which handwashing protocol is most efficacious. We evaluated six handwashing protocols (soap and water, alcohol-based hand sanitizer (ABHS), and 0.05% sodium dichloroisocyanurate, high-test hypochlorite, and stabilized and non-stabilized sodium hypochlorite solutions) for 1) efficacy of handwashing on the removal and inactivation of non-pathogenic model organisms and, 2) persistence of organisms in rinse water. Model organisms E. coli and bacteriophage Phi6 were used to evaluate handwashing with and without organic load added to simulate bodily fluids. Hands were inoculated with test organisms, washed, and rinsed using a glove juice method to retrieve remaining organisms. Impact was estimated by comparing the log reduction in organisms after handwashing to the log reduction without handwashing. Rinse water was collected to test for persistence of organisms. Handwashing resulted in a 1.94-3.01 log reduction in E. coli concentration without, and 2.18-3.34 with, soil load; and a 2.44-3.06 log reduction in Phi6 without, and 2.71-3.69 with, soil load. HTH performed most consistently well, with significantly greater log reductions than other handwashing protocols in three models. However, the magnitude of handwashing efficacy differences was small, suggesting protocols are similarly efficacious. Rinse water demonstrated a 0.28-4.77 log reduction in remaining E. coli without, and 0.21-4.49 with, soil load and a 1.26-2.02 log reduction in Phi6 without, and 1.30-2.20 with, soil load. Chlorine resulted in significantly less persistence of E. coli in both conditions and Phi6 without soil load in rinse water (phand hygiene in Ebola contexts, considering the potential benefit of chlorine-based methods in rinse water persistence.

  19. Optimization of the etch-and-rinse technique: New perspectives to improve resin-dentin bonding and hybrid layer integrity by reducing residual water using dimethyl sulfoxide pretreatments.

    Science.gov (United States)

    Stape, Thiago Henrique Scarabello; Tjäderhane, Leo; Abuna, Gabriel; Sinhoreti, Mário Alexandre Coelho; Martins, Luís Roberto Marcondes; Tezvergil-Mutluay, Arzu

    2018-04-13

    To determine whether bonding effectiveness and hybrid layer integrity on acid-etched dehydrated dentin would be comparable to the conventional wet-bonding technique through new dentin biomodification approaches using dimethyl sulfoxide (DMSO). Etched dentin surfaces from extracted sound molars were randomly bonded in wet or dry conditions (30s air drying) with DMSO/ethanol or DMSO/H 2 O as pretreatments using a simplified (Scotchbond Universal Adhesive, 3M ESPE: SU) and a multi-step (Adper Scotchbond Multi-Purpose, 3M ESPE: SBMP) etch-and-rinse adhesives. Untreated dentin surfaces served as control. Bonded teeth (n=8) were stored in distilled water for 24h and sectioned into resin-dentin beams (0.8mm 2 ) for microtensile bond strength test and quantitative interfacial nanoleakage analysis (n=8) under SEM. Additional teeth (n=2) were prepared for micropermeability assessment by CFLSM under simulated pulpar pressure (20cm H 2 O) using 5mM fluorescein as a tracer. Microtensile data was analyzed by 3-way ANOVA followed by Tukey Test and nanoleakage by Kruskal-Wallis and Dunn-Bonferroni multiple comparison test (α=0.05). While dry-bonding of SBMP produced significantly lower bond strengths than wet-bonding (padhesives to demineralized air-dried dentin beyond conventional wet-bonding. Less porous resin-dentin interfaces with higher bond strengths on air-dried etched dentin were achieved; nonetheless, overall efficiency varied according to DMSO's co-solvent and adhesive type. DMSO pretreatments permit etched dentin to be air-dried before hybridization facilitating residual water removal and thus improving bonding effectiveness. This challenges the current paradigm of wet-bonding requirement for the etch-and-rinse approach creating new possibilities to enhance the clinical longevity of resin-dentin interfaces. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.

  20. Handwashing and Ebola virus disease outbreaks: A randomized comparison of soap, hand sanitizer, and 0.05% chlorine solutions on the inactivation and removal of model organisms Phi6 and E. coli from hands and persistence in rinse water.

    Directory of Open Access Journals (Sweden)

    Marlene K Wolfe

    Full Text Available To prevent Ebola transmission, frequent handwashing is recommended in Ebola Treatment Units and communities. However, little is known about which handwashing protocol is most efficacious. We evaluated six handwashing protocols (soap and water, alcohol-based hand sanitizer (ABHS, and 0.05% sodium dichloroisocyanurate, high-test hypochlorite, and stabilized and non-stabilized sodium hypochlorite solutions for 1 efficacy of handwashing on the removal and inactivation of non-pathogenic model organisms and, 2 persistence of organisms in rinse water. Model organisms E. coli and bacteriophage Phi6 were used to evaluate handwashing with and without organic load added to simulate bodily fluids. Hands were inoculated with test organisms, washed, and rinsed using a glove juice method to retrieve remaining organisms. Impact was estimated by comparing the log reduction in organisms after handwashing to the log reduction without handwashing. Rinse water was collected to test for persistence of organisms. Handwashing resulted in a 1.94-3.01 log reduction in E. coli concentration without, and 2.18-3.34 with, soil load; and a 2.44-3.06 log reduction in Phi6 without, and 2.71-3.69 with, soil load. HTH performed most consistently well, with significantly greater log reductions than other handwashing protocols in three models. However, the magnitude of handwashing efficacy differences was small, suggesting protocols are similarly efficacious. Rinse water demonstrated a 0.28-4.77 log reduction in remaining E. coli without, and 0.21-4.49 with, soil load and a 1.26-2.02 log reduction in Phi6 without, and 1.30-2.20 with, soil load. Chlorine resulted in significantly less persistence of E. coli in both conditions and Phi6 without soil load in rinse water (p<0.001. Thus, chlorine-based methods may offer a benefit of reducing persistence in rinse water. We recommend responders use the most practical handwashing method to ensure hand hygiene in Ebola contexts, considering

  1. A 5 year longitudinal study of water quality for final rinsing in the single chamber washer-disinfector with a reverse osmosis plant.

    Science.gov (United States)

    Uetera, Yushi; Kishii, Kozue; Yasuhara, Hiroshi; Kumada, Naohito; Moriya, Kyoji; Saito, Ryoichi; Okazaki, Mitsuhiro; Misawa, Yoshiki; Kawamura, Kunio

    2013-01-01

    This report deals with the construction and management of the reverse osmosis (RO) water system for final rinsing of surgical instruments in the washer-disinfector. Numerous operational challenges were encountered in our RO water system and these were analyzed utilizing the Ishikawa Fishbone diagram. The aim was to find potential problems and promote preventive system management for RO water. It was found that the measures that existed were inappropriate for preventing contamination in the heat-labile RO water system. The storage tank was found to be significantly contaminated and had to be replaced with a new one equipped with a sampling port and water drainage system. Additional filters and an UV treatment lamp were installed. The whole system disinfection started 1.5 years later using a peracetic acid-based compound after confirming the material compatibility. Operator errors were found when a new water engineer took over the duty from his predecessor. It was also found that there were some deficiencies in the standard operating procedures (SOPs), and that on-the-job training was not enough. The water engineer failed to disinfect the sampling port and water drainage system. The RO membrane had been used for 4 years, even though the SOP standard specified changing it as every 3 years. Various bacteria, such as Rothia mucilaginosa, were cultured from the RO water sampled from the equipment. Because Rothia mucilaginosa is a resident in the oral cavity and upper respiratory tract, it is believed that the bacteria were introduced into the system by the maintenance personnel or working environment. Therefore, the presence of R. mucilaginosa implied the failure of sanitary maintenance procedures. This study suggests that water systems should be designed based on the plans for profound system maintenance. It also suggests that SOP and on-the job training are essential to avoid any operator errors. These results must be carefully considered when either constructing new

  2. Nickel removal from nickel plating waste water using a biologically active moving-bed sand filter.

    Science.gov (United States)

    Pümpel, Thomas; Macaskie, Lynne E; Finlay, John A; Diels, Ludo; Tsezos, Marios

    2003-12-01

    Efficient removal of dissolved nickel was observed in a biologically active moving-bed 'MERESAFIN' sand filter treating rinsing water from an electroless nickel plating plant. Although nickel is fully soluble in this waste water, its passage through the sand filter promoted rapid removal of approximately 1 mg Ni/l. The speciation of Ni in the waste water was modelled; the most probable precipitates forming under the conditions in the filter were predicted using PHREEQC. Analyses of the Ni-containing biosludge using chemical, electron microscopical and X-ray spectroscopic techniques confirmed crystallisation of nickel phosphate as arupite (Ni3(PO4)2 x 8H2O), together with hydroxyapatite within the bacterial biofilm on the filter sand grains. Biosorption contributed less than 1% of the overall sequestered nickel. Metabolising bacteria are essential for the process; the definitive role of specific components of the mixed population is undefined but the increase in pH promoted by metabolic activity of some microbial components is likely to promote nickel desolubilisation by others.

  3. Pseudo-outbreak of Cupriavidus pauculus infection at an outpatient clinic related to rinsing culturette swabs in tap water.

    Science.gov (United States)

    Balada-Llasat, Joan-Miquel; Elkins, Camille; Swyers, Lettie; Bannerman, Tammy; Pancholi, Preeti

    2010-07-01

    Cupriavidus pauculus is a water microorganism rarely isolated from clinical specimens. We describe a pseudo-outbreak in which multiple strains that were associated with moistening of culturette swabs with tap water were isolated from a single clinic before collecting the patient specimen.

  4. Dynamic Analysis of Plate in Water Tank

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kang Soo; Jeong, Kyeng Hoon; Koo, Gyeong Hoi [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    A pool door (Plate) is installed at the chase of the pool gate by means of an overhead crane in the building of a research reactor. The principal function of the pool door, which is located between the reactor pool and service pool, is to separate the reactor pool from the service pool for the maintenance and/or the removal of the equipment either in the reactor pool or service pool. A stress analysis for each component of the pool door was conducted against the given loads including the seismic load. Because the stresses for the analysis results were lower than the design limits for the given material, the structural integrity for the given dimension of the pool door was confirmed.

  5. Fluoride Rinses, Gels and Foams

    DEFF Research Database (Denmark)

    Twetman, Svante; Keller, Mette K

    2016-01-01

    AIM: The aim of this conference paper was to systematically review the quality of evidence and summarize the findings of clinical trials published after 2002 using fluoride mouth rinses, fluoride gels or foams for the prevention of dental caries. METHODS: Relevant papers were selected after...... (6 on fluoride mouth rinse, 10 on fluoride gel and 3 on fluoride foam); 6 had a low risk of bias while 2 had a moderate risk. All fluoride measures appeared to be beneficial in preventing crown caries and reversing root caries, but the quality of evidence was graded as low for fluoride mouth rinse......, moderate for fluoride gel and very low for acidulated fluoride foam. No conclusions could be drawn on the cost-effectiveness. CONCLUSIONS: This review, covering the recent decade, has further substantiated the evidence for a caries-preventive effect of fluoride mouth rinse, fluoride gel and foam...

  6. Measurements of total suspended matter - How does salinity and the amount of rinse water influence the results; Maetning av totalt suspenderat material - Hur paaverkar salthalt och maengden skoeljvatten resultatet

    Energy Technology Data Exchange (ETDEWEB)

    Hall, Bjoern (Bjoern Hall, Miljoe och Foerbraenningskemi, Onsala (Sweden))

    2010-03-15

    Under regulations for incineration of waste NFS 2002:28 total suspended matter (tsm) in wastewater from incineration plants are analyzed by daily sampling measurement or by representative flow-proportional 24-hour test. It has been shown that many plants that analyzes the suspended matter according to EN 872:2005 are having trouble keeping their conditions for suspended solids constant. This applies mainly to plants rated for a high chloride content in the closing process. Waste Sweden has for years drawn attention to this problem and have with a joint working group with representatives from the Swedish waste incineration plants tried to obtain a better understanding of this phenomenon. The basic question is whether the water from the facilities in question really contain high levels of tsm or if there is something else behind the observed concentrations. The results from this study suggest that the most important factor is the salinity and the amount of rinse water used in the analysis. Under the standard, all samples are washed with 2 x 20 ml of water. If salinity exceeds 1000 mg/l, a further 3 x 50 ml used. How this process is this implemented in practice varies from laboratory to laboratory and there is no laboratory that regularly measure the salinity of the sample. It is not specified especially when submitting the sample uses most of the labs normal rinse water of 2 x 20 ml. The findings also indicate that the samples with very high salinities the standard stipulated 190 mls is not enough. This would likely lead to that further rinse water is needed. In order to establish safe Several measurements would be needed to confirm this assumption. A relatively simple way to obtain an idea of the salinity of the test is to measure its conductivity. Accordingly, this could be a first step on to get a more consistent performance than is the case at present

  7. Decolorization and degradation of reactive dye during the dyed cotton fabric rinsing process.

    Science.gov (United States)

    Luo, Deng-Hong; Zheng, Qing-Kang; Chen, Sheng; Liu, Qing-Shu; Wang, Xiu-Xing; Guan, Yu; Pu, Zong-Yao

    2010-01-01

    Dyeing process of textile consumes large quantities of water, which results in huge amounts of colored wastewater. Most of the dye wastewater treating methods focused on the treatment of wastewater after the rinsing process of dyed textile. In this paper, tetraacetylethylenediamine/hydrogen peroxide (TAED/H₂O₂) active oxidation (AO) system was developed to rinse dyed textile and decolorize the rinsing wastewater simultaneously. The results indicated that the decolorization ratio of the rinse effluent obtained by AO method were in the range of 51.72%-84.15% according to different dyes and the COD value decreased more than 30% compared with that of traditional rinsing process. The decolorization kinetics investigation showed that the decolorization of dyes during AO rinsing process followed the law of pseudo-first order kinetics. The result of UV-Vis and UPLC-MS analysis demonstrated that the dye was degraded into colorless organic molecular fragments and partly mineralized during the AO rinsing process.

  8. Chemical vs. herbal formulations as pre-procedural mouth rinses to combat aerosol production: A randomized controlled study

    Directory of Open Access Journals (Sweden)

    Koduganti Rekha Rani

    2014-01-01

    Full Text Available Background: Disease transmission and barrier techniques are the key concerns during ultrasonic instrumentation as this procedure has the hazard of aerosol production which has a multitude of deleterious effects on the body. The aerosol produced can affect both the patient and the clinician. The aim of this study was to assess the importance of pre-procedural rinsing before scaling by ultrasonic instrumentation and to compare the efficacy of commercially available herbal mouth rinse and a Chlorhexidine gluconate mouth rinse with a control group. The study was conducted from 1 st February to 15 th April 2012 in a tertiary referral care hospital. The study was approved by the institutional ethical committee. This was a randomized single blinded interventional study, where in 36 patients equally divided into three groups participated. Material and Methods: Thirty six patients were recruited in this study aged between 18-35 years. All patients had plaque index scores between1.5-3.0, and were categorized into three groups. Patients with systemic diseases and on antibiotic therapy were excluded. Group A or control group underwent scaling with water as pre-procedural rinse, Group B used 20 ml of 0.2% Chlorhexidine and group C were administered 18 ml of a herbal pre-procedural rinse. Aerosol splatter produced during the procedure were collected on blood agar plates and sent for microbiologic analysis for the assessment of bacterial Colony Forming Units (CFUs. The mean CFUs and standard deviation (SD for each group were measured. Post hoc test was used to compare the differences between three groups, Control (A Chlorhexidine (B and Herbal (C. Results: The mean Colony Forming Units (CFUs for control group was 114.50, Chlorhexidine group was 56.75 and herbal rinse group was 47.38. Conclusion: Pre-procedural rinsing was found to be effective in reducing aerosol contamination during ultrasonic scaling though no statistically significant difference was found

  9. Laboratory procedure for sizing and electroless nickel plating assembled steel bearings

    International Nuclear Information System (INIS)

    Wright, R.R.; Petit, G.S.

    1976-01-01

    The bearing is placed in a holder and degreased in methyl chloroform. The entire bearing is etched in hydrochloric acid and sized in an ammonium bifluoride-hydrogen peroxide solution (NH 4 F.HF--H 2 O 2 ). The bearing is removed from the holder, activated in hydrochloric acid and plated with 0.001 in. of nickel in a plating tumbler immersed in a heated electroless nickel plating bath. The bearing is water-rinsed and air-dried

  10. [Comparison of novel infrared heating plates and conventional warm water plates for piglets' creep areas in farrowing pens].

    Science.gov (United States)

    Strauch-Sürken, L; Wendt, M

    2015-01-01

    On a conventionally managed piglet-producing farm, novel infrared (IR) heating plates for piglets in the farrowing pens were tested for their suitability and compared with common warm-water (WW) heating plates. In total, 134 litters (summer n = 82, winter n = 52) were investigated, which were housed on IR or WW heating plates, respectively, with or without an extra cover plate (groups 1-4). To determine the influence of the different heat sources, the wound healing after castration and tail docking, the umbilical regression and the weight gain of the piglets were investigated. Additionally, the lying behavior of the piglets and the position of the sows' udder at the time of farrowing were examined with regard to the heating plates. Furthermore, the energy consumption and costs were compared. The piglets housed on IR heating plates displayed better wound healing after castration and tail docking than the piglets housed on WW plates. The best results were obtained in piglets kept on IR heating plates with an extra cover plate. In addition, significant benefits were demonstrated for the usage of IR heating plates regarding umbilical regression. The piglets kept on IR heating plates had a slightly better weight gain in summer, whereas there were no differences between groups during winter. The lying behavior in the creep areas was similar in all groups. In general, with increasing age the percentage of time piglets spent in the lying position on the plates decreased. The percentage of time lying on the plates was higher in winter than in summer. At farrowing, 74.6% of all investigated sows directed their udder towards the heating plates. With the IR heating plates, this behavior occurred significantly more often. The energy consumption (kWh) per litter was significantly lower for the IR heating plates (electric power) both in winter and summer in comparison with the WW plates (gas). The energy costs were comparable in summer, but were higher for the IR heating plates

  11. Rinse, Reuse and Scream

    Science.gov (United States)

    Sutley, Jane

    2009-01-01

    The author of this article describes how her eighth grade art students heighten their awareness of differences between their public self and their inner self by: manipulating water bottles to create sculptural self-portraits; constructing armatures of the generic person in "The Scream" by Edward Munch; finding and collecting examples of images and…

  12. Rinsing with antacid suspension reduces hydrochloric acid-induced erosion.

    Science.gov (United States)

    Alves, Maria do Socorro Coelho; Mantilla, Taís Fonseca; Bridi, Enrico Coser; Basting, Roberta Tarkany; França, Fabiana Mantovani Gomes; Amaral, Flávia Lucisano Botelho; Turssi, Cecilia Pedroso

    2016-01-01

    Mouthrinsing with antacids, following erosive episodes, have been suggested as a preventative strategy to minimize tooth surface loss due to their neutralizing effect. The purpose of this in situ study was to evaluate the effect of an antacid suspension containing sodium alginate, sodium bicarbonate and calcium carbonate in controlling simulated erosion of enamel of intrinsic origin. The experimental units were 48 slabs (3×3×2mm) of bovine enamel, randomly divided among 12 volunteers who wore palatal appliances with two enamel slabs. One of them was exposed extra-orally twice a day to 25mL of a hydrochloric acid (HCl) solution (0.01M, pH 2) for 2min. There were two independent phases, lasting 5 days each. In the first phase, according to a random scheme, half of the participants rinsed with 10mL of antacid suspension (Gaviscon(®), Reckitt Benckiser Healthcare Ltd.), while the remainder was rinsed with deionized water, for 1min. For the second phase, new slabs were inserted and participants switched to the treatment not received in the first stage. Therefore, the groups were as follows: (a) erosive challenge with HCl+antacid suspension; (b) erosive challenge with HCl+deionized water (DIW); (c) no erosive challenge+antacid suspension; (d) no erosive challenge+DIW. Specimens were assessed in terms of surface loss using optical profilometry and Knoop microhardness. The data were analyzed using repeated measures two-way analysis of variance and Tukey's tests. Compared to DIW rinses, surface loss of enamel was significantly lower when using an antacid rinse following erosive challenges (p=0.015). The Knoop microhardness of the enamel was significantly higher when the antacid rinse was used (p=0.026). The antacid suspension containing sodium alginate, sodium bicarbonate and calcium carbonate, rinsed after erosive challenges of intrinsic origin, reduced enamel surface loss. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Experiences with the ASDEX neutralizer plates and construction of water-cooled plates for long-pulse heating

    International Nuclear Information System (INIS)

    Rapp, H.; Niedermeyer, H.; Kornherr, M.

    1987-01-01

    After dismantling of the titanium neutralizer plates inspection yielded satisfactory status of flat areas whereas edges and curved shapes were heavily melted. At the inner plates of the lower divertor strongly focused melting and cutting was found which is caused by fast electrons. These electrons are continuously produced. The production mechanism is not yet clear but runaway processes can be excluded. With long-pulse additional heating of 6 MW/10s as planned for ASDEX in 1987, the total energy delivered to the plasma will increase by a factor of 30. Therefore new water-cooled neutralizer plates have been constructed which consist of a copper-steel compound. The construction principle and the topology of the cooling circuits is presented

  14. Microsecond Electrical Discharge in Water in Plate-to-Plate Configuration With Nitrogen Bubble Injection

    Czech Academy of Sciences Publication Activity Database

    Stelmashuk, Vitaliy

    2016-01-01

    Roč. 44, č. 4 (2016), s. 702-707 ISSN 0093-3813 Institutional support: RVO:61389021 Keywords : Electric breakdown * plate electrodes * underwater discharge Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.052, year: 2016 http://ieeexplore.ieee.org/xpl/tocresult.jsp?isnumber=7450213

  15. Sodium Bicarbonate mouth rinse: An Uncommon Complication

    OpenAIRE

    Fatih Mehmet Coskunses

    2012-01-01

    Sodium bicarbonate is a natural buffer that maintains a healthy pH in mouth to promote a clean and fresh oral environment. Sodium-bicarbonate rinse is empirically suggested to patients by dentist and people around, and may prove to be harmful. In this short communication, we present chemical burn of oral mucosa because of sodium-bicarbonate rinse after misfit dental impression.

  16. Inactivation of Heterosigma akashiwo in ballast water by circular orifice plate-generated hydrodynamic cavitation.

    Science.gov (United States)

    Feng, Daolun; Zhao, Jie; Liu, Tian

    2016-01-01

    The discharge of alien ballast water is a well-known, major reason for marine species invasion. Here, circular orifice plate-generated hydrodynamic cavitation was used to inactivate Heterosigma akashiwo in ballast water. In comparison with single- and multihole orifice plates, the conical-hole orifice plate yielded the highest inactivation percentage, 51.12%, and consumed only 6.84% energy (based on a 50% inactivation percentage). Repeating treatment, either using double series-connection or circling inactivation, elevated the inactivation percentage, yet consumed much more energy. The results indicate that conical-hole-generated hydrodynamic cavitation shows great potential as a pre-inactivation method for ballast water treatment.

  17. Countercurrent air/water and steam/water flow above a perforated plate. Report for October 1978-October 1979

    International Nuclear Information System (INIS)

    Hsieh, C.; Bankoff, S.G.; Tankin, R.S.; Yuen, M.C.

    1980-11-01

    The perforated plate weeping phenomena have been studied in both air/water and steam/cold water systems. The air/water experiment is designed to investigate the effect of geometric factors of the perforated plate on the rate of weeping. A new dimensionless flow rate in the form of H star is suggested. The data obtained are successfully correlated by this H star scaling in the conventional flooding equation. The steam/cold water experiment is concentrated on locating the boundary between weeping and no weeping. The effects of water subcooling, water inlet flow rate, and position of water spray are investigated. Depending on the combination of these factors, several types of weeping were observed. The data obtained at high water spray position can be related to the air/water flooding correlation by replacing the stream flow rate to an effective stream flow rate, which is determined by the mixing efficiency above the plate

  18. Presence and absence of a water film between moving air bubbles and a plate

    International Nuclear Information System (INIS)

    Remenyik, C.J.

    1990-01-01

    The thickness of water films between an inclined Lucite plate submerged in water and air bubbles moving beneath it was measured with a small impedance probe. The instrument was calibrated with a laser interferometer built for this purpose. The bubbles released beneath the plate varied in size from 10 cc to 100 cc. At a plate inclination angle of 0.98 degree, and in tap water, an uninterrupted water film covered most of the bubbles. Some bubbles, however, dewetted the plate, and the water film covered only a forward part of the bubble. When the film was uninterrupted, its thickness was very uniform from front to rear. When the bubble dewetted the plate, a large forward section of the film had the same uniform thickness, but this was followed by a hump on the film the rear slope of which ended at the plate surface. For some of the experiments, the surface tension of the water was reduced by admixing a detergent. In these experiments, dewetting was not observed. In a second set of experiments, a hand held transparent container filled with water and a 1.3 cm3 air bubble was used to observe visually the behavior of the moving bubble and its associated water film

  19. Caramel, uranium oxide fuel plates for water cooled reactors

    International Nuclear Information System (INIS)

    Bussy, Pierre; Delafosse, Jacques; Lestiboudois, Guy; Cerles, J.-M.; Schwartz, J.-P.

    1979-01-01

    The fuel is composed of thin plates assembled parallel to each other to form bundles or assemblies. Each plate is composed of a pavement of uranium oxide pellets, insulated from each other by a zircaloy cladding. The 235 U enrichment does not exceed 8%. The range of uses for this fuel extends from electric power generating reactors to irradiation reactors for research work. A parametric study in test loops has made it possible to determine the operating limits of this thick fuel, without bursting. The resulting diagram gives the permissible power densities, with and without cycling for specific burn-ups beyond 50,000 MWd/t. The thinnest plates were also irradiated in total in the form of advance assemblies irradiated in the core of the OSIRIS pile prior to its transformation. This transformation and the operation of this reactor with a core of 'Caramel' elements is the main trial experiment of this fuel [fr

  20. Modular Porous Plate Sublimator /MPPS/ requires only water supply for coolant

    Science.gov (United States)

    Rathbun, R. J.

    1966-01-01

    Modular porous plate sublimators, provided for each location where heat must be dissipated, conserve the battery power of a space vehicle by eliminating the coolant pump. The sublimator requires only a water supply for coolant.

  1. THE EFFECT OF MOUTH RINSES ON THE COLOR STABILITY OF SONICFILL AND A NANOHYBRID COMPOSITE

    Directory of Open Access Journals (Sweden)

    Tuğba Toz-Akalın

    2016-04-01

    Full Text Available Purpose: The aim of this study was to evaluate the effects of 4 mouth rinses on the color stability of two different resin composites. Materials and Methods: A2 shade sonic-activated bulk fill material SonicFill (Kerr and conventional nanohybrid composite Filtek Z550 (3M ESPE were used. Forty disc-shaped specimens (10 mm x 2 mm were fabricated for both composites and finished using 400-grit SiC paper and polished. After polishing and immersing in distilled water for 24h all specimens were subjected to color measurements. The baseline color values (L*, a*, b* of each specimen were measured with a colorimeter. Following baseline measurement each composite group was divided into 5 groups: Oral-B Pro Expert Clinic Line Alcoholfree (Oral-B group, Listerine Tooth Defense Rinse (Listerine group, Pharmol Zn Mouth rinse (Çözümilaç group, Nilera Mouth rinse (Nilera group and Distilled water (control group. The specimens were incubated in mouth rinses (20 ml at 37°C for 12 hours and subjected to color measurement. Two-way ANO VA was used for statistical analysis (p<0.05. Results: SonicFill showed significantly higher discoloration when exposed to Oral-B Pro Expert Clinic Line Alcohol-free, Listerine Tooth Defense Rinse and Pharmol Zn Mouth rinse. The color differences of two resin composites were not statistically significant for distilled water and Nilera Mouth rinse. Conclusion: Within the limits of this study it can be concluded that the SonicFill showed higher discoloration than nanohybrid resin composite Filtek Z550.

  2. The effect of rinsing time periods on wettability of elastomeric impression materials: in vitro study

    Directory of Open Access Journals (Sweden)

    Özlem Acar

    2016-01-01

    Full Text Available OBJECTIVE: The aim of this study was to determine whether different rinsing time periods affected the wettability of polymerized elastomeric impression materials. MATERIALS AND METHOD: Panasil Contact Plus (PCP, Panasil Contact Non-Surfactant (PCNS, Panasil Initial Contact (PIC, Express (EXP and Impregum (IMP impression materials were tested. Standardized samples were rinsed with water for 10 s, 15 s or 20 s, and the wettability was determined by contact angle measurement through an evaluation period of 60 seconds (n=7. Non-rinsed groups were used as control. Measurements were made at 5 time points (at 0, 6, 15, 30 and 60 seconds. Kruskal Wallis test and Conover’s multiple comparison tests were used for all multiple comparisons. Bonferroni adjustment was applied for controlling Type I error (p0.002. CONCLUSION: Rinsing the surfactant-containing polyvinylsiloxane impression materials decreased their wettability, whereas no such effect was seen for the surfactant free polyvinylsiloxane and polyether impression materials.

  3. Cetylpyridinium chloride mouth rinses alleviate experimental gingivitis by inhibiting dental plaque maturation.

    Science.gov (United States)

    Teng, Fei; He, Tao; Huang, Shi; Bo, Cun-Pei; Li, Zhen; Chang, Jin-Lan; Liu, Ji-Quan; Charbonneau, Duane; Xu, Jian; Li, Rui; Ling, Jun-Qi

    2016-09-29

    Oral rinses containing chemotherapeutic agents, such as cetylpyridinium chloride (CPC), can alleviate plaque-induced gingival infections, but how oral microbiota respond to these treatments in human population remains poorly understood. Via a double-blinded, randomised controlled trial of 91 subjects, the impact of CPC-containing oral rinses on supragingival plaque was investigated in experimental gingivitis, where the subjects, after a 21-day period of dental prophylaxis to achieve healthy gingivae, received either CPC rinses or water for 21 days. Within-subject temporal dynamics of plaque microbiota and symptoms of gingivitis were profiled via 16S ribosomal DNA gene pyrosequencing and assessment with the Mazza gingival index. Cetylpyridinium chloride conferred gingival benefits, as progression of gingival inflammation resulting from a lack of dental hygiene was significantly slower in the mouth rinse group than in the water group due to inhibition of 17 gingivitis-enriched bacterial genera. Tracking of plaque α and β diversity revealed that CPC treatment prevents acquisition of new taxa that would otherwise accumulate but maintains the original biodiversity of healthy plaques. Furthermore, CPC rinses reduced the size, local connectivity and microbiota-wide connectivity of the bacterial correlation network, particularly for nodes representing gingivitis-enriched taxa. The findings of this study provide mechanistic insights into the impact of oral rinses on the progression and maturation of dental plaque in the natural human population.

  4. Water in geodynamical models of mantle convection and plate tectonics

    Science.gov (United States)

    Rodríguez-González, J.; Van Hunen, J.; Chotalia, K.; Lithgow-Bertelloni, C. R.; Rozel, A.; Tackley, P. J.; Nakagawa, T.

    2017-12-01

    The presence of water in the the mantle has a significant effect in the dynamical and thermal evolution of Earth, which partially explains the differences with other planets and is a key factor for the presence of life on Earth. First, a small amount of water can decrease the mantle viscosity by a several orders of magnitude, thereby changing the convection regime and affecting the thermal evolution. Second, the presence of water significantly changes the solidus curve, with crucial implications for melting. Third, water in the mantle can change the Clapeyron slope of mantle materials, which changes the depth at which phase transitions take place. The thermal and dynamical evolution of Earth under the presence of water in the mantle has been the focus of recent studies, but many questions remain unanswered. In this project we intend to investigate how the maximum water capacity of different mantle regions affects water transport and Earth's convective regime. We will study the effect phase transitions under the presence of water, which can change the buoyancy of slabs in the transition zone. We present preliminary results numerical models of global mantle convection for the whole history of earth using the numerical geodynamics software tool StagYY. We will use a new parametrisation of dehydration processes, obtained from high-resolution numerical simulations, to implement a more accurate description of the water released from the slab as it travels through the mantle. We have integrated recent experimental results of the water capacity of deep mantle minerals to study the water circulation and the total water budget. We use data from the most recent experiments and ab-inito calculations to implement a realistic rheology.

  5. Development of high pressure rinsing set up for 650 MHz, 5- cell superconducting RF cavity cleaning

    International Nuclear Information System (INIS)

    Suhane, S.K.; Chauhan, S.K.; Bose, A.; Kokil, S.V.; Rajput, D.S.; Oraon, B.; Md Hussain; Sahu, A.; Raghavendra, S.; Joshi, S.C.

    2015-01-01

    High pressure rinsing (HPR) is an ultra-cleanliness process for the surface preparation of high field superconducting RF cavities. Any dust particle or chemical residue on the interior of cavity causes field emission. Jets of high pressure (80-100 bar) ultra pure water dislodge surface contaminants that normally resist removal with conventional rinsing procedures, leading to substantial reduction in field emission and better cavity performance. For cleaning of 650 MHz, 5-cell SRF cavities, a high pressure rinsing set up has been developed at RRCAT. The HPR tool has a rotating wand coaxial with the vertically mounted SRF cavity that is moving up and down. Fan style spray nozzles are attached to the end of the rotating wand and the water jets emerging from spray nozzles scan the entire internal surface of the cavity. The set-up was installed in a specially built clean area meeting cleanliness class 100 standards. The ultrapure water with resistivity 2 ≥ 18 MΩ-cm required for rinsing is obtained from a dedicated water purification system installed for this purpose. The paper describes the salient design and constructional details of the high pressure rinsing set up. Characterization of water jet parameters based on the momentum transfer between the water jet and a load cell is also presented. (author)

  6. The effect of sodium bicarbonate oral rinse on salivary pH and oral microflora: A prospective cohort study.

    Science.gov (United States)

    Chandel, Siddhartha; Khan, Mohsin Ali; Singh, Nishi; Agrawal, Amiya; Khare, Vinita

    2017-01-01

    Present study is designed to explore the effect of sodium bicarbonate oral rinse on salivary pH and oral micro flora. Twenty five healthy subjects were recruited for the study in department of dentistry in Era Medical College. Subjects were abstained from tooth brushing overnight pre rinse (control) samples were collected after one hour of dinner and were asked to rinse with pre calibrated freshly prepared sodium bicarbonate solution. The salivary samples were then collected the following morning using sterile gauze in marked bottles. Aerobic bacterial culture was done by plating the sample directly from the swab on the surface of Blood agar and Mac Conkeys media respectively. The colony forming units and ph were calculated for the pre rinse and post rinse saliva sample. Results shows that salivary pH increased significantly after sodium Bicarbonate oral rinse. There was a marginal decrease in number of CFU/ml for bacteria especially Viridans Streptococci, Moraxella species. Sodium Bicarbonate oral rinse may be considered as a cheap and effective alternative for chlorhexidine and alcohol based mouth wash, especially where long duration usage is required.

  7. The numerical simulation of the performances of water rotors used in pipelines with the water baffle plates

    Energy Technology Data Exchange (ETDEWEB)

    Altan, Burcin Deda [Pamukkale University, Kinikli (Turkmenistan)

    2014-11-15

    In this study, obtaining energy especially from large and medium sized pipelines used for drinking water, rain water, or even some used for waste water has been aimed. In line with this objective, it has been investigated how to increase the performance of the water rotors used in the pipelines in order to benefit optimally from the energy of the flowing fluid in pipe. Furthermore, in order to increase the performance of the water rotor used in pipelines, a water baffle plate has been placed in front of the water rotor. In this way, the effects of size parameters of the water rotor used in the pipeline in conjunction with the various design parameters of the water baffle plate on the power performance of rotor has been investigated. By comparing design parameters, the number of the water rotor blades has also been investigated. Optimization steps have been carried out with numerical results of the study supported by theoretical computation. For numerical optimization of the water rotor, both static and dynamic performances of rotor have been found. According to the optimization study, the maximum power performance values have been obtained from a power pipe unit which consists of a water rotor and a water baffle plate with (x{sub g} /r{sub r} = 0.1, y{sub g}/r{sub r} = 0.4, ve r{sub r}/r{sub p} = 0.4 ve α = 60 .deg. ) size ratios.

  8. The numerical simulation of the performances of water rotors used in pipelines with the water baffle plates

    International Nuclear Information System (INIS)

    Altan, Burcin Deda

    2014-01-01

    In this study, obtaining energy especially from large and medium sized pipelines used for drinking water, rain water, or even some used for waste water has been aimed. In line with this objective, it has been investigated how to increase the performance of the water rotors used in the pipelines in order to benefit optimally from the energy of the flowing fluid in pipe. Furthermore, in order to increase the performance of the water rotor used in pipelines, a water baffle plate has been placed in front of the water rotor. In this way, the effects of size parameters of the water rotor used in the pipeline in conjunction with the various design parameters of the water baffle plate on the power performance of rotor has been investigated. By comparing design parameters, the number of the water rotor blades has also been investigated. Optimization steps have been carried out with numerical results of the study supported by theoretical computation. For numerical optimization of the water rotor, both static and dynamic performances of rotor have been found. According to the optimization study, the maximum power performance values have been obtained from a power pipe unit which consists of a water rotor and a water baffle plate with (x g /r r = 0.1, y g /r r = 0.4, ve r r /r p = 0.4 ve α = 60 .deg. ) size ratios.

  9. Sinus Rinsing and Neti Pots

    Science.gov (United States)

    ... not to be used for routine or emergency drinking water disinfection. We have added an extra amount of bleach ... not to be used for routine or emergency drinking water disinfection. As mentioned above, we have added an extra ...

  10. Influence of material anisotropy on the hydroelastic response of composite plates in water

    Science.gov (United States)

    Akcabay, Deniz Tolga; Young, Yin Lu

    2018-03-01

    Flexible lightweight plate-like lifting surfaces in external flows have a diverse range of use from propelling and controlling marine and aerospace vehicles to converting wind and ocean energy to electrical energy. Design and analysis of such structures are complex for underwater applications where the water density is much higher than air. The hydrodynamic loads, which vary with the inflow speed, can significantly alter the dynamic response and stability. This paper focuses on the hydroelastic response of composite plates in water. The results show that the dynamics and stability of the structure can be significantly modified by taking advantage of the material anisotropic; on the contrary, careless composite material designs may lead to unwanted dynamic instability failures. The resonance frequencies, divergence speeds, and fluid loss coefficients change with material anisotropy and hydrodynamic loads. The resonance frequencies are much lower in water than in air. The critical divergence speed increases, if the principal fiber direction is oriented towards the inflow. Hydrodynamic damping is shown to be much higher than the material damping, and tend to increase with flow speed and to decrease with increasing modal frequency. The paper derives Response Amplitude Operators (RAOs) for sample composite plates in water and use them to predict the motion response when subject to stochastic flow excitations. We show how material anisotropy can be used to passively tailor the plate vibration response spectrum to limit or enhance flow-induced vibrations of the plate depending on the desired applications.

  11. Experimental observations and modelling of thermal history within a steel plate during water jet impingement

    International Nuclear Information System (INIS)

    Liu, Z.D.; Fraser, D.; Samarasekera, I.V.; Lockhart, G.T.

    2002-01-01

    In order to investigate heat transfer of steel plates under a water jet impingement and to further simulate runout table operation in a hot strip mill, a full-scale pilot runout table facility was designed and constructed at the University of British Columbia (UBC). This paper describes the experimental details, data acquisition and data handling techniques for steel plates during water jet impingement by one circular water jet from an industrial header. Recorded visual observations at the impinging surface were obtained. The effects of cooling water temperature and impingement velocity on the heat transfer from a steel plate were studied. A two-dimensional finite element method-based transient inverse heat conduction model was developed. With the help of the model, heat fluxes and heat transfer coefficients along the impinging surface under various cooling conditions were calculated. The microstructural evolution of the steel plate was also investigated for the varying cooling conditions. Samples were obtained from each plate, polished, etched and then photographed. (author)

  12. Corrosion Behavior of Nickel-Plated Alloy 600 in High Temperature Water

    International Nuclear Information System (INIS)

    Kim, Ji Hyun; Hwang, Il Soon

    2008-01-01

    In this paper, electrochemical and microstructural characteristics of nickel-plated Alloy 600 wee investigated in order to identify the performance of electroless Ni-plating on Alloy 600 in high-temperature aqueous condition with the comparison of electrolytic nickel-plating. For high temperature corrosion test of nickel-plated Alloy 600, specimens were exposed for 770 hours to typical PWR primary water condition. During the test, open circuit potentials (OCP's) of all specimens were measured using a reference electrode. Also, resistance to flow accelerated corrosion (FAC) test was examined in order to check the durability of plated layers in high-velocity flow environment at high temperature. After exposures to high flow rate aqueous condition, the integrity of surfaces was confirmed by using both scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). For the field application, a remote process for electroless nickel-plating was demonstrated using a plate specimen with narrow gap on a laboratory scale. Finally, a practical seal design was suggested for more convenient application

  13. Temperature dependence of the evaporation lengthscale for water confined between two hydrophobic plates.

    Science.gov (United States)

    Djikaev, Yuri S; Ruckenstein, Eli

    2015-07-01

    Liquid water in a hydrophobic confinement is the object of high interest in physicochemical sciences. Confined between two macroscopic hydrophobic surfaces, liquid water transforms into vapor if the distance between surfaces is smaller than a critical separation, referred to as the evaporation lengthscale. To investigate the temperature dependence of the evaporation lengthscale of water confined between two hydrophobic parallel plates, we use the combination of the density functional theory (DFT) with the probabilistic hydrogen bond (PHB) model for water-water hydrogen bonding. The PHB model provides an analytic expression for the average number of hydrogen bonds per water molecule as a function of its distance to a hydrophobic surface and its curvature. Knowing this expression, one can implement the effect of hydrogen bonding between water molecules on their interaction with the hydrophobe into DFT, which is then employed to determine the distribution of water molecules between two macroscopic hydrophobic plates at various interplate distances and various temperatures. For water confined between hydrophobic plates, our results suggest the evaporation lengthscale to be of the order of several nanometers and a linearly increasing function of temperature from T=293 K to T=333 K, qualitatively consistent with previous results. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Low velocity impact on polymer composite plates in contact with water

    Directory of Open Access Journals (Sweden)

    Y Kwon

    2016-09-01

    Full Text Available In this study, composite materials were tested in two different environments to determine the role of Fluid Structure Interaction with composites under a low velocity impact. This was done using a low velocity impact machine and polymer composite plates. The composite is made of laminated symmetrical plain weave E-glass fabrics. The test area of the composite plates is 30.5 cm by 30.5 cm with clamped boundary conditions. The testing was done using a drop weight system to impact the center of the test area. One testing was performed with composite plates in air, called dry impact. The other testing was conducted while composite plates were submerged in water, called wet impact. A Plexiglas box in conjunction with the impact machine was used to keep the top of the composite sample dry while it was submerged in an anechoic water tank, so called water-backed air impact. Output from the tests was recorded using strain gauges and a force impact sensor. The results show that an added mass effect from the water plays a large role in the Fluid Structure Interaction with composites due to the similar densities of water and the composites. The wet impact results in a larger impact force and damage than the dry impact under the same impact condition, i.e., the same impact mass and drop height.

  15. Performance enhancement studies in a thermosyphon flat plate solar water heater with CuO nanofluid

    Directory of Open Access Journals (Sweden)

    Dasaien Anin Vincely

    2017-01-01

    Full Text Available Experiments were conducted on a thermosyphon type flat plate collector, inclined at 45°, for water heating application. Water and water based nanofluids were used as absorber fluid to gain heat from solar rays incident on the flat plate col-lector. Nanofluids were prepared by adding CuO nanoparticles of 40-50 nm size to the base fluid at 0.1, 0.2, 0.3, and 0.5 wt% (ζ. The hot absorber fluid was made to circulate in the shell side of a heat exchanger, placed at the top of the flat plate collector, where utility water was circulated inside a helically coiled Cu tube. Temperatures at strategic locations in the flat plate collector, working fluid, utility water inlet and outlet were measured. The nanofluid increases the collector efficiency with increasing ζ. A highest efficiency enhancement of 5.7% was observed for the nanofluid with ζ = 0.2 having a mass flow rate of 0.0033 kg/s. The 3-D, steady-state, conjugate heat transfer CFD analyses were carried out using the ANSYS FLUENT 15.0 software. Theoretically estimated buoyancy induced fluid flow rates were close with the CFD predictions and thus validates the computational methodology.

  16. Dynamically slow processes in supercooled water confined between hydrophobic plates

    Energy Technology Data Exchange (ETDEWEB)

    Franzese, Giancarlo [Departamento de Fisica Fundamental, Universidad de Barcelona, Diagonal 647, Barcelona 08028 (Spain); Santos, Francisco de los, E-mail: gfranzese@ub.ed, E-mail: fdlsant@ugr.e [Departamento de Electromagnetismo y Fisica de la Materia, Universidad de Granada, Fuentenueva s/n, 18071 Granada (Spain)

    2009-12-16

    We study the dynamics of water confined between hydrophobic flat surfaces at low temperature. At different pressures, we observe different behaviors that we understand in terms of the hydrogen bond dynamics. At high pressure, the formation of the open structure of the hydrogen bond network is inhibited and the surfaces can be rapidly dried (dewetted) by formation of a large cavity with decreasing temperature. At lower pressure we observe strong non-exponential behavior of the correlation function, but with no strong increase of the correlation time. This behavior can be associated, on the one hand, to the rapid ordering of the hydrogen bonds that generates heterogeneities and, on the other hand, to the lack of a single timescale as a consequence of the cooperativity in the vicinity of the liquid-liquid critical point that characterizes the phase diagram at low temperature of the water model considered here. At very low pressures, the gradual formation of the hydrogen bond network is responsible for the large increase of the correlation time and, eventually, the dynamical arrest of the system, with a strikingly different dewetting process, characterized by the formation of many small cavities.

  17. Dynamically slow processes in supercooled water confined between hydrophobic plates

    International Nuclear Information System (INIS)

    Franzese, Giancarlo; Santos, Francisco de los

    2009-01-01

    We study the dynamics of water confined between hydrophobic flat surfaces at low temperature. At different pressures, we observe different behaviors that we understand in terms of the hydrogen bond dynamics. At high pressure, the formation of the open structure of the hydrogen bond network is inhibited and the surfaces can be rapidly dried (dewetted) by formation of a large cavity with decreasing temperature. At lower pressure we observe strong non-exponential behavior of the correlation function, but with no strong increase of the correlation time. This behavior can be associated, on the one hand, to the rapid ordering of the hydrogen bonds that generates heterogeneities and, on the other hand, to the lack of a single timescale as a consequence of the cooperativity in the vicinity of the liquid-liquid critical point that characterizes the phase diagram at low temperature of the water model considered here. At very low pressures, the gradual formation of the hydrogen bond network is responsible for the large increase of the correlation time and, eventually, the dynamical arrest of the system, with a strikingly different dewetting process, characterized by the formation of many small cavities.

  18. The flow in an oil/water plate heat exchanger for the automotive industry

    OpenAIRE

    Lozano , A.; Barreras , F.; Fueyo , N.; Santodomingo , S.

    2008-01-01

    The flow in an oil/water plate heat exchanger for the automotive industry correspondence: Corresponding author. Tel.: +34976716463; fax: +34976716456. (Lozano, A.) (Lozano, A.) LITEC/CSIC--> , Mar?'a de Luna 10--> , 50018--> , Zaragoza--> - SPAIN (Lozano, A.) SPAIN (Lozano, A.) LITEC/CSIC--> , Mar?'a de Luna 10--> , 50018--> , Zaragoza--> - S...

  19. A figure of merit for selective absorbers in flat plate solar water heaters

    CSIR Research Space (South Africa)

    Roberts, DE

    2013-12-01

    Full Text Available We derive from first principles an analytical expression for a figure of merit (FM) for a selective solar absorber in a single glazed flat plate water heater. We first show that the efficiency of a collector with an absorber with absorptance α...

  20. Production of monodispersed Oil-in Water Emulsion Using Crossflow-Type Silicon Microchannel Plate

    Energy Technology Data Exchange (ETDEWEB)

    Kawakatsu, Takahiro.; Komori, Hideaki.; Yonemoto, Toshikuni. [Tohoku University, Miyagi (Japan). Chemical Engineering Department; Nakajima, Mitsutoshi.; Kikuchi, Yuji. [National Food Research Institute, Ibaraki (Japan)

    1999-04-01

    A novel method for continuous productin of monodispersed oil-in-water (O/W) emulsion is developed using acrossflow-type silicaon microchannel plate. On the single crystal silicon plate, a liquid flow path for continuous phase was made, and at each side of th wall of the path an array of regular-sized slits was precisely fabricated. A flat glass plate was tightly attached on the microchannel plate to cover the top of the slits to form the array of microchannels. Regular-sized oil (triolein) droplets were generated by squeezing the oil through the microchannels into the continuous-phase water (0.3 wt% sodium lauryl sulfate solutin) flowing in the liquid path. Oil droplet size is significantly dependent on the microchannel structure, which is identified with the microchannel width, height, and the length of the terrace (a flat area at the microchannel outlet). Three types of microchannel plates having different microchannel structures generate monodispersed emulsions of different average droplet sizes, 16,20, and 48 {mu}m at the watr flow rate of 1.4x10{sup -2}mL{center_dot}min{sup -1}. For the microchannel plate which generates large droplets of 48 {mu}m, increasing the flow rate causes decreasing droplet size. However, for the microchannel plate which generates small droplets of 16 or 20 {mu}m, the size is not affected by the flow rate within the range from 1.4x10{sup -2}to 2.4 mL{center_dot}min{sup -1}. In every case, the droplet size distribution is narrow, and the geometric standard deviation is 1.03 or less. (author)

  1. Variation in Lateral Plate Quality in Threespine Stickleback from Fresh, Brackish and Marine Water: A Micro-Computed Tomography Study.

    Directory of Open Access Journals (Sweden)

    Elisabeth Wiig

    Full Text Available It is important to understand the drivers leading to adaptive phenotypic diversity within and among species. The threespine stickleback (Gasterosteus aculeatus has become a model system for investigating the genetic and phenotypic responses during repeated colonization of fresh waters from the original marine habitat. During the freshwater colonization process there has been a recurrent and parallel reduction in the number of lateral bone plates, making it a suitable system for studying adaptability and parallel evolution.The aim of this study was to investigate an alternative evolutionary path of lateral plate reduction, where lateral plates are reduced in size rather than number.A total of 72 threespine stickleback individuals from freshwater (n = 54, brackish water (n = 27 and marine water (n = 9 were analysed using microcomputed tomography (μCT to determine variation in size, thickness and structure of the lateral plates. Furthermore, whole-body bone volume, and bone volume, bone surface and porosity of lateral plate number 4 were quantified in all specimens from each environment.The results showed a significant difference in plate size (area and volume among populations, where threespine stickleback from polymorphic freshwater and brackish water populations displayed lateral plates reduced in size (area and volume compared to marine stickleback.Reduction of lateral plates in threespine stickleback in fresh and brackish water occurs by both plate loss and reduction in plate size (area and volume.

  2. PERFORMANCE DETERIORATION OF THERMOSIPHON SOLAR FLAT PLATE WATER HEATER DUE TO SCALING

    OpenAIRE

    arunachala umesh chandavar

    2011-01-01

    The performance of Flat plate Solar Water Heater deteriorates within five to twelve years of their installation due to factors related to manufacturing, operating conditions, lack of maintenance etc. Especially, problem due to scaling is significant as it is based on quality of water used. The remaining factors are system dependent and could be overcome by quality production. Software is developed by incorporating Hottel Whillier Bliss (H-W-B) equation to ascertain the effect of scaling o...

  3. Natural convection in a water tank with a heated horizontal plate facing downward

    International Nuclear Information System (INIS)

    Yang, Sun Kyoo; Jung, Moon Kee; Helmut Hoffmann

    1995-01-01

    Experimental and computational studies were carried out to investigate the natural convection of the single phase flow in a tank with a heated horizontal plate facing downward. This is a simplified model for investigations of the influence of a core melt at the bottom of a reactor vessel on the thermal hydraulic behavior in a water filled cavity surrounding the vessel. In this case the vessel is simulated by a hexahedron insulated box with a heated plate horizontally mounted at the bottom of the box. The box with the heated plate is installed in a water filled hexahedron tank. Coolers are immersed in the U-type water volume between the box and the tank. Although the multicomponent flows exist more probably below the heated plate in reality, present study concentrates on the single phase flow in a first step prior to investigating the complicated multicomponent thermal hydraulic phenomena. In the present study, in order to get a better understanding for the natural convection characteristics below the heated plate, the velocity and temperature are measured by LDA(Laser Doppler Anemometry) and thermocouples, respectively. And flow fields are visualized by taking pictures of the flow region with suspended particles. The results show the occurrence of a very effective circulation of the fluid in the whole flow area as the heater and coolers are put into operation. In the remote region below the heated plate the flow is nearly stagnant, and a remarkable temperature stratification can be observed with very thin thermal boundary. Analytical predictions using the FLUTAN code show a reasonable matching of the measured velocity fields. 18 figs., 2 tabs., 18 refs. (Author)

  4. Fluoride varnish or fluoride mouth rinse?

    DEFF Research Database (Denmark)

    Keller, M K; Klausen, BJ; Twetman, S

    2016-01-01

    OBJECTIVE: In many Danish communities, school-based fluoride programs are offered to children with high caries risk in adjunct to tooth brushing. The purpose of this field trial was to compare the caries-preventive effectiveness of two different fluoride programs in 6-12 year olds. BASIC RESEARCH...... different schools were enrolled after informed consent and their class unit was randomly allocated to one of two fluoride programs. INTERVENTIONS: One group received a semi-annual fluoride varnish applications (FV) and the other group continued with an existing program with fluoride mouth rinses once per...... in caries development over two years among children participating in a school-based fluoride varnish or mouth rinse program....

  5. Water recycling from mixed chromic acid waste effluents by membrane technology

    NARCIS (Netherlands)

    Frenzel, I.; Frenzel, I.; Stamatialis, Dimitrios; Wessling, Matthias

    2006-01-01

    Approaching zero discharge waste on site requires economical treatment technologies for the plating industry, recovering high quality rinse water for reuse. The combination of membranes and evaporation could be an efficient way to downsize the cost and the energy intensive evaporation equipment. In

  6. Study of the effect of water vapor on a resistive plate chamber with glass electrodes

    CERN Document Server

    Sakai, H H; Teramoto, Y; Nakano, E E; Takahashi, T T

    2002-01-01

    We studied the effects of water vapor on the efficiencies of resistive plate chambers with glass electrodes, operated in the streamer mode. With moisture in the chamber gas that has freon as a component (water vapor approx 1000 ppm), a decrease in the efficiency (approx 20%) has been observed after operating for a period of several weeks to a few months. From our study, the cause of the efficiency decrease was identified as a change on the cathode surface. In addition, a recovery method was found: flushing for 1 day with argon bubbled through water containing >=3% ammonia, followed by a few weeks of training with dry gas.

  7. Large zero-tension plate lysimeters for soil water and solute collection in undisturbed soils

    Directory of Open Access Journals (Sweden)

    A. Peters

    2009-09-01

    Full Text Available Water collection from undisturbed unsaturated soils to estimate in situ water and solute fluxes in the field is a challenge, in particular if soils are heterogeneous. Large sampling devices are required if preferential flow paths are present. We present a modular plate system that allows installation of large zero-tension lysimeter plates under undisturbed soils in the field. To investigate the influence of the lysimeter on the water flow field in the soil, a numerical 2-D simulation study was conducted for homogeneous soils with uni- and bimodal pore-size distributions and stochastic Miller-Miller heterogeneity. The collection efficiency was found to be highly dependent on the hydraulic functions, infiltration rate, and lysimeter size, and was furthermore affected by the degree of heterogeneity. In homogeneous soils with high saturated conductivities the devices perform poorly and even large lysimeters (width 250 cm can be bypassed by the soil water. Heterogeneities of soil hydraulic properties result into a network of flow channels that enhance the sampling efficiency of the lysimeter plates. Solute breakthrough into zero-tension lysimeter occurs slightly retarded as compared to the free soil, but concentrations in the collected water are similar to the mean flux concentration in the undisturbed soil. To validate the results from the numerical study, a dual tracer study with seven lysimeters of 1.25×1.25 m area was conducted in the field. Three lysimeters were installed underneath a 1.2 m filling of contaminated silty sand, the others deeper in the undisturbed soil. The lysimeters directly underneath the filled soil material collected water with a collection efficiency of 45%. The deeper lysimeters did not collect any water. The arrival of the tracers showed that almost all collected water came from preferential flow paths.

  8. Cavitation inception in nozzle-plate and wire mesh pressure droppers in water and sodium

    International Nuclear Information System (INIS)

    Collinson, A.E.

    1976-01-01

    Cavitation tests on multi-hole nozzle plates and wire meshes approximately 100mm diameter in water at 20 deg C and sodium at 300 deg C are described. These pressure dropping elements were mounted in recirculating loops where cavitation was induced by gradually lowering the back-ground pressure at constant flow. Cavitation was detected acoustically using wall mounted piezoelectric microphones, the signal being displayed on a ratemeter recording individual cavitation events. For nozzle plates, cavitation started intermittently as the pressure was lowered, the noise level suddenly increasing at a critical cavitation number sigma. For meshes the intermittent region was absent. Values of sigma for nozzles and meshes were similar in water and sodium for the conditions prevailing during the tests. It was apparent that cavitation took place on the axes of vortices both in the free stream and close to nozzle curved surfaces

  9. The use of lithium as a marker for the retention of liquids in the oral cavity after rinsing.

    Science.gov (United States)

    Hanning, Sara M; Kieser, Jules A; Ferguson, Martin M; Reid, Malcolm; Medlicott, Natalie J

    2014-01-01

    The aim of this study was to validate the use of lithium as a marker to indicate the retention of simple liquids in the oral cavity and use this to determine how much liquid is retained in the oral cavity following 30 s of rinsing. This is a validation study in which saliva was spiked with known concentrations of lithium. Twenty healthy participants then rinsed their mouths with either water or a 1 % w/v carboxymethylcellulose (CMC) solution for 30 s before expectorating into a collection cup. Total volume and concentration of lithium in the expectorant were then measured, and the percentage of liquid retained was calculated. The mean amount of liquid retained was 10.4 ± 4.7 % following rinsing with water and 15.3 ± 4.1 % following rinsing with 1 % w/v CMC solution. This difference was significant (p < 0.01). Lithium was useful as a marker for the retention of liquids in the oral cavity, and a value for the amount of water and 1 % w/v CMC solution remaining in the oral cavity following a 30-s rinse was established. The present study quantifies the retention of simple fluids in the oral cavity, validating a technique that may be applied to more complex fluids such as mouth rinses. Further, the application of this method to specific population groups such as those with severe xerostomia may assist in developing effective saliva substitutes.

  10. Performance of a LiBr water absorption chiller operating with plate heat exchangers

    OpenAIRE

    Vega Blázquez, Mercedes de; Almendros Ibáñez, José Antonio; Ruiz, G.

    2006-01-01

    This paper studies the performance of a lithium bromide water absorption chiller operating with plate heat exchangers (PHE). The overall heat transfer coefficients in the desorber, the condenser and the solution heat recoverer are calculated using the correlations provided in the literature for evaporation, condensation and liquid to liquid heat transfer in PHEs. The variable parameters are the external driving temperatures. In the desorber, the inlet temperature of the hot fluid ranges from ...

  11. Relation between the amount of dissolved water and metals dissolved from stainless steel or aluminum plate in safflower oil

    Energy Technology Data Exchange (ETDEWEB)

    Takasago, Masahisa; Takaoka, Kyo

    1986-12-01

    The amount of water dissolved in safflower oil at the frying temperature (180 deg C) was 518 -- 1012 ppM, allowing water to drop continuously (0.035 g/2 min) into the oil for 1 -- 3 h. When the oil was heated with metal plates under the same conditions, the amount of dissolved water in the oil increased more than in the absence of the metal plates. In case of stainless steel, the amount was 1.26 to 1.33 times, and with aluminum plates, 1.06 to 1.13 times the amount without plates. When these metal plates were heated with the oil under the above conditions, the water dissolved the metal of the plates into the oil. In case of stainless steel, iron dissolved from 0.17 to 0.77 ppM, nickel, 0.04 ppM and chromium, from 0.02 to 0.03 ppM. Similarly, the amount of aluminum dissolved from the aluminum plate was from 0.10 to 0.45 ppM.

  12. The relation between the amount of dissolved water and metals dissolved from stainless steel or aluminum plate in safflower oil

    International Nuclear Information System (INIS)

    Takasago, Masahisa; Takaoka, Kyo

    1986-01-01

    The amount of water dissolved in safflower oil at the frying temperature (180 deg C) was 518 ∼ 1012 ppm, allowing water to drop continuously (0.035 g/2 min) into the oil for 1 ∼ 3 h. When the oil was heated with metal plates under the same conditions, the amount of dissolved water in the oil increased more than in the absence of the metal plates. In case of stainless steel, the amount was 1.26 to 1.33 times, and with aluminum plates, 1.06 to 1.13 times the amount without plates. When these metal plates were heated with the oil under the above conditions, the water dissolved the metal of the plates into the oil. In case of stainless steel, iron dissolved from 0.17 to 0.77 ppm, nickel, 0.04 ppm and chromium, from 0.02 to 0.03 ppm. Similarly, the amount of aluminum dissolved from the aluminum plate was from 0.10 to 0.45 ppm. (author)

  13. Efficacy of dental rinse formulations marketed in Abuja, Nigeria in ...

    African Journals Online (AJOL)

    This study assessed the microbial quality and effectiveness of seven brands of antiseptic dental rinses marketed in Abuja, Nigeria. Seven brands of dental rinses were randomly purchased from the open market and pharmacies. According to the products literature, the brands contained sodium fluoride + triclosan, sodium ...

  14. Flat plate solar collector for water pre-heating using concentrated solar power (CSP)

    Science.gov (United States)

    Peris, Leonard Sunny; Shekh, Md. Al Amin; Sarker, Imran

    2017-12-01

    Numerous attempt and experimental conduction on different methods to harness energy from renewable sources are being conducted. This study is a contribution to the purpose of harnessing solar energy as a renewable source by using flat plate solar collector medium to preheat water. Basic theory of solar radiation and heat convection in water (working fluid) has been combined with heat conduction process by using copper tubes and aluminum absorber plate in a closed conduit, covered with a glazed through glass medium. By this experimental conduction, a temperature elevation of 35°C in 10 minutes duration which is of 61.58% efficiency range (maximum) has been achieved. The obtained data and experimental findings are validated with the theoretical formulation and an experimental demonstration model. A cost effective and simple form of heat energy extraction method for space heating/power generation has been thoroughly discussed with possible industrial implementation possibilities. Under-developed and developing countries can take this work as an illustration for renewable energy utilization for sustainable energy prospect. Also a full structure based data to derive concentrated solar energy in any geographical location of Bangladesh has been outlined in this study. These research findings can contribute to a large extent for setting up any solar based power plant in Bangladesh irrespective of its installation type.

  15. Molecular dynamics simulations of ultrathin water film confined between flat diamond plates

    Directory of Open Access Journals (Sweden)

    A.V. Khomenko

    2008-12-01

    Full Text Available Molecular dynamics simulations of ultrathin water film confined between atomically flat rigid diamond plates are described. Films with thickness of one and two molecular diameters are concerned and TIP4P model is used for water molecules. Dynamical and equilibrium characteristics of the system for different values of the external load and shear force are investigated. An increase of the external load causes the transition of the film to a solidlike state. This is manifested in a decrease of the diffusion constant and in the ordering of the liquid molecules into quasidiscrete layers. For two-layer film under high loads, the molecules also become ordered parallel to the surfaces. Time dependencies of the friction force and the changes of its average value with the load are obtained. In general, the behaviour of the studied model is consistent with the experimental results obtained for simple liquids with spherical molecules.

  16. Numerical study on the effects of absorptivity on performance of flat plate solar collector of a water heater

    Science.gov (United States)

    Tambunan, D. R. S.; Sibagariang, Y. P.; Ambarita, H.; Napitupulu, F. H.; Kawai, H.

    2018-03-01

    The characteristics of absorber plate of a flat plate solar collector play an important role in the improvement of the performance. In this work, a numerical analysis is carried out to explore the effect of absorptivity and emissivity of absorber plate to the performance of the solar collector of a solar water heater. For a results comparison, a simple a simple solar box cooker with absorber area of 0.835 m × 0.835 m is designed and fabricated. It is employed to heat water in a container by exposing to the solar radiation in Medan city of Indonesia. The transient governing equations are developed. The governing equations are discretized and solved using the forward time step marching technique. The results reveal that the experimental and numerical results show good agreement. The absorptivity of the plate absorber and emissivity of the glass cover strongly affect the performance of the solar collector.

  17. Drilling and cutting of thin metal plates in water with radiation of a repetitively pulsed Nd : YAG laser

    Energy Technology Data Exchange (ETDEWEB)

    Glova, A F; Lysikov, A Yu [State Research Center of Russian Federation ' Troitsk Institute for Innovation and Fusion Research' , Troitsk, Moscow Region (Russian Federation)

    2011-10-31

    The conditions of drilling and cutting of 0.15-mm-thick titanium and stainless steel plates in water with the radiation of a repetitively pulsed Nd : YAG laser having the mean power up to 30 W are studied experimentally in the absence of water and gas jets. Dependences of the maximal cutting speed in water on the radiation power are obtained, the cutting efficiency is determined, and the comparison with the conditions of drilling and cutting of plates in air is carried out.

  18. Flow cytometric bacterial cell counts challenge conventional heterotrophic plate counts for routine microbiological drinking water monitoring

    KAUST Repository

    Van Nevel, S.

    2017-02-08

    Drinking water utilities and researchers continue to rely on the century-old heterotrophic plate counts (HPC) method for routine assessment of general microbiological water quality. Bacterial cell counting with flow cytometry (FCM) is one of a number of alternative methods that challenge this status quo and provide an opportunity for improved water quality monitoring. After more than a decade of application in drinking water research, FCM methodology is optimised and established for routine application, supported by a considerable amount of data from multiple full-scale studies. Bacterial cell concentrations obtained by FCM enable quantification of the entire bacterial community instead of the minute fraction of cultivable bacteria detected with HPC (typically < 1% of all bacteria). FCM measurements are reproducible with relative standard deviations below 3% and can be available within 15 min of samples arriving in the laboratory. High throughput sample processing and complete automation are feasible and FCM analysis is arguably less expensive than HPC when measuring more than 15 water samples per day, depending on the laboratory and selected staining procedure(s). Moreover, many studies have shown FCM total (TCC) and intact (ICC) cell concentrations to be reliable and robust process variables, responsive to changes in the bacterial abundance and relevant for characterising and monitoring drinking water treatment and distribution systems. The purpose of this critical review is to initiate a constructive discussion on whether FCM could replace HPC in routine water quality monitoring. We argue that FCM provides a faster, more descriptive and more representative quantification of bacterial abundance in drinking water.

  19. Flow cytometric bacterial cell counts challenge conventional heterotrophic plate counts for routine microbiological drinking water monitoring

    KAUST Repository

    Van Nevel, S.; Koetzsch, S.; Proctor, C.R.; Besmer, M.D.; Prest, E.I.; Vrouwenvelder, Johannes S.; Knezev, A.; Boon, N.; Hammes, F.

    2017-01-01

    Drinking water utilities and researchers continue to rely on the century-old heterotrophic plate counts (HPC) method for routine assessment of general microbiological water quality. Bacterial cell counting with flow cytometry (FCM) is one of a number of alternative methods that challenge this status quo and provide an opportunity for improved water quality monitoring. After more than a decade of application in drinking water research, FCM methodology is optimised and established for routine application, supported by a considerable amount of data from multiple full-scale studies. Bacterial cell concentrations obtained by FCM enable quantification of the entire bacterial community instead of the minute fraction of cultivable bacteria detected with HPC (typically < 1% of all bacteria). FCM measurements are reproducible with relative standard deviations below 3% and can be available within 15 min of samples arriving in the laboratory. High throughput sample processing and complete automation are feasible and FCM analysis is arguably less expensive than HPC when measuring more than 15 water samples per day, depending on the laboratory and selected staining procedure(s). Moreover, many studies have shown FCM total (TCC) and intact (ICC) cell concentrations to be reliable and robust process variables, responsive to changes in the bacterial abundance and relevant for characterising and monitoring drinking water treatment and distribution systems. The purpose of this critical review is to initiate a constructive discussion on whether FCM could replace HPC in routine water quality monitoring. We argue that FCM provides a faster, more descriptive and more representative quantification of bacterial abundance in drinking water.

  20. Prevenção de cárie dentária por bochechos com flúor em município com água fluoretada Fluoride mouth-rinsing to prevent dental caries in a Brazilian municipality with fluoridated drinking water

    Directory of Open Access Journals (Sweden)

    Maria Luiza Hiromi Iwakura

    2004-04-01

    Full Text Available OBJETIVO: Comparar a prevalência de cárie dentária em escolares que participaram de um programa semanal de bochecho com fluoreto de sódio a 0,2% com a prevalência de cárie em escolares que não participaram do programa. MÉTODOS: Estudo transversal na Cidade de Londrina, Estado do Paraná, Brasil, cuja população consome água fluoretada. Foram examinados 367 escolares de 12 anos: 190 participantes (51,8% e 177 não participantes (48,2% do programa semanal de bochecho. Os índices utilizados foram o de dentes cariados, perdidos e obturados e o de superfícies cariadas, perdidas e obturadas. Os exames foram conduzidos por três examinadores e a concordância no diagnóstico de cárie foi quase perfeita (K = 0,90. A cárie dentária foi considerada variável dependente. As variáveis independentes foram: a participação ou não no programa, estudar em escola pública ou privada, escovação dentária, quantidade de dentifrício utilizada, ingestão de doces e consulta ao dentista. RESULTADOS: O índice de dentes cariados, perdidos e obturados aos 12 anos foi 0,85 ± 0,059 (0,70 ±0,060 para não participantes e 1,0 ±0,058 para participantes. O índice de superfícies cariadas, perdidas e obturadas foi 1,16 ±0,017, variando de 0,34 a 1,66. Na análise bivariada, estiveram estatisticamente associados (P OBJECTIVE: To compare the prevalence of dental caries in two groups of schoolchildren: (1 schoolchildren participating in a weekly 0.2% sodium fluoride mouth-rinsing program and (2 schoolchildren not participating in the program. METHODS: This cross-sectional study was conducted in the city (municipality of Londrina, in the state of Paraná, Brazil; the city has fluoridated drinking water. We examined 367 12-year-old children: 190 participants in the weekly mouth-rinsing program (51.8% and 177 nonparticipants (48.2%. The prevalence of caries was determined based on the scores for decayed, missing, and filled teeth and for decayed, missing

  1. In vitro evaluation of the whitening effect of mouth rinses containing hydrogen peroxide

    Directory of Open Access Journals (Sweden)

    Fábio Garcia Lima

    2012-06-01

    Full Text Available The aim of this study was to evaluate the bleaching effect of two mouth rinses containing hydrogen peroxide. Thirty premolars were randomly divided into two groups (n = 15: Listerine Whitening (LW and Colgate Plax Whitening (PW. The teeth were fixed on a wax plate and with acrylic resin, at a distance of 5 mm between each other, exposing the buccal surfaces. All teeth were stored in artificial saliva for 45 days, being removed twice a day to be immersed for 1 min in each mouthwash, followed by 10-second washing in tap water. The pH of each product was measured. Digital images of each tooth were captured under standardized conditions. These images were cut in areas previously demarcated and analyzed in Adobe Photoshop 7.0 using the CIEL*a*b* color space system. Data were statistically analyzed by a paired t test and an independent samples t test (p < 0.05. The pH values were 5.6 and 3.4 for LW and PW, respectively. Both treatment groups showed a decrease in the b* parameter (p < 0.01, but a decrease of a* was observed only for PW (p < 0.01. While the LW group showed an improvement in lightness (L* (p = 0.03, the PW group had a decrease in the L* parameter (p = 0.02. Within the limitations of this study, it is possible to conclude that both products caused some degree of whitening; however, extreme care should be taken when using Colgate Plax Whitening, since its decline in luminosity might be due to its lower pH.

  2. Visualization of the contact line during the water exit of flat plates

    Science.gov (United States)

    Tassin, A.; Breton, T.; Forest, B.; Ohana, J.; Chalony, S.; Le Roux, D.; Tancray, A.

    2017-08-01

    We investigate experimentally the time evolution of the wetted surface during the lifting of a body initially floating at the water surface. This phenomenon is referred to as the water exit problem. The water exit experiments were conducted with transparent (PMMA) mock-ups of two different shapes: a circular disc and a square flat plate. Two different lighting systems were used to diffuse light in the mock-up material: a central high-power LED light normal to the surface and an edge-lighting system featuring an array of LED lights. These setups make it possible to illuminate the contact line, which delimits the surface of contact between the mock-up and the water. The characteristic size of the mock-ups is about 20 cm and the acceleration of the mock-up oscillates between 0 and 25 m/s^2. We show that the central light setup gives satisfactory results for the circular disc and that the edge lighting technique makes it possible to follow a contact line with a time-evolving complex shape (strong changes of convexity) up to 1000 fps. The observations presented in the paper support the possibility of extending this promising technique to more general three-dimensional bodies with arbitrary motion (e.g., including pitch motion).

  3. Water, oceanic fracture zones and the lubrication of subducting plate boundaries—insights from seismicity

    Science.gov (United States)

    Schlaphorst, David; Kendall, J.-Michael; Collier, Jenny S.; Verdon, James P.; Blundy, Jon; Baptie, Brian; Latchman, Joan L.; Massin, Frederic; Bouin, Marie-Paule

    2016-03-01

    We investigate the relationship between subduction processes and related seismicity for the Lesser Antilles Arc using the Gutenberg-Richter law. This power law describes the earthquake-magnitude distribution, with the gradient of the cumulative magnitude distribution being commonly known as the b-value. The Lesser Antilles Arc was chosen because of its along-strike variability in sediment subduction and the transition from subduction to strike-slip movement towards its northern and southern ends. The data are derived from the seismicity catalogues from the Seismic Research Centre of The University of the West Indies and the Observatoires Volcanologiques et Sismologiques of the Institut de Physique du Globe de Paris and consist of subcrustal events primarily from the slab interface. The b-value is found using a Kolmogorov-Smirnov test for a maximum-likelihood straight line-fitting routine. We investigate spatial variations in b-values using a grid-search with circular cells as well as an along-arc projection. Tests with different algorithms and the two independent earthquake cataloges provide confidence in the robustness of our results. We observe a strong spatial variability of the b-value that cannot be explained by the uncertainties. Rather than obtaining a simple north-south b-value distribution suggestive of the dominant control on earthquake triggering being water released from the sedimentary cover on the incoming American Plates, or a b-value distribution that correlates with on the obliquity of subduction, we obtain a series of discrete, high b-value `bull's-eyes' along strike. These bull's-eyes, which indicate stress release through a higher fraction of small earthquakes, coincide with the locations of known incoming oceanic fracture zones on the American Plates. We interpret the results in terms of water being delivered to the Lesser Antilles subduction zone in the vicinity of fracture zones providing lubrication and thus changing the character of the

  4. The effective removal method of copper and cyanide in waste water of metal plating factories

    International Nuclear Information System (INIS)

    Jae, Won Mok; Hong, Zong Doo; Kim, Myun Sup

    1988-01-01

    To investigate the effective removal method of cooper and cyanide compounds in metal plating waste water, removal ratio of cooper and cyanide compounds in solution are measured with varying pH, concentration and contact time. As results of the present experiment, cyanide compounds in the solution are removed to 0.03mg/l or less with 5% NaOCl solution. The present result is satisfied to environmental disposal standards. The removal ratio against pH values show 99% over pH8. As results of neutral precipitation method, copper including solution are removed to 99% at pH8 in short time. The removal ratios of cyanide mixed copper solution against pH values show high efficiency(over 95%) at pH8 and 11 and removal ratios are decreased at pH10.(Author)

  5. Water resistant rhodium plated reflectors for use in the DIRC BaBar Cherenkov detector

    CERN Document Server

    Benkebil, M; Plaszczynski, S; Schune, M H; Wormser, G

    2000-01-01

    Early simulation studies showed that reflectors mounted on the photomultipliers would be useful for the DIRC BaBar Cherenkov detector, showing a gain between 20% and 30% in the number of Cherenkov photons. The proof of principle for these reflectors has been obtained during the beam test of a large-scale prototype of the DIRC detector. An extensive R and D has been conducted in order to test different metallization procedures. Indeed, the challenge was to find a metallization technique which can resist the pure de-ionized water (>15 M OMEGA) up to 10 yr. The chosen technology was rhodium plated reflectors. During the first BaBar cosmic run, the measured performance confirmed the results of the simulation, the prototype-II and the R and D.

  6. Boundary Layer Flow and Heat Transfer of FMWCNT/Water Nanofluids over a Flat Plate

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Safaei

    2016-09-01

    Full Text Available In the present study, the heat transfer and flow of water/FMWCNT (functionalized multi-walled carbon nanotube nanofluids over a flat plate was investigated using a finite volume method. Simulations were performed for velocity ranging from 0.17 mm/s to 1.7 mm/s under laminar regime and nanotube concentrations up to 0.2%. The 2-D governing equations were solved using an in-house FORTRAN code. For a specific free stream velocity, the presented results showed that increasing the weight percentage of nanotubes increased the Nusselt number. However, an increase in the solid weight percentage had a negligible effect on the wall shear stress. The results also indicated that increasing the free stream velocity for all cases leads to thinner boundary layer thickness, while increasing the FMWCNT concentration causes an increase in the boundary layer thickness.

  7. Heat transfer from a plate cooled by a water film with countercurrent air flow

    International Nuclear Information System (INIS)

    Ambrosini, W.; Manfredini, A.; Mariotti, F.; Oriolo, F.; Vigni, P.

    1995-01-01

    An experimental program at the University of Pisa provides specific data for the evaluation of heat and mass transfer by falling film evaporation. The problem is addressed primarily because of its relevance to the study of the behavior of passive containment cooling systems in simplified pressurized water reactors. In these plants, after an accident that releases vapor from the primary circuit, the steel containment envelope is cooled either by an ascending stream of air in natural circulation or by the combination of air flow and falling film evaporation. To qualify models for the prediction of the heat transfer capabilities in postulated accident conditions, researchers have built an experimental facility consisting of a flat heated plate with water sprays and a fan to simulate a countercurrent air stream. The range of relevant parameters to be investigated has been determined on the basis of integral calculations performed for the AP600 reactor containment. The facility has enabled the collection of data that confirm the adequacy of the classical heat and mass transfer analogy in predicting evaporation phenomena. Further developments in the research are needed to confirm the first results and to extend the experimental database by considering more subtle aspects of the phenomenon such as the characteristics of surface waviness of the water film and its effect on heat transfer

  8. Relationship of a turbidity of an oral rinse with oral health and malodor in Vietnamese patients.

    Science.gov (United States)

    Pham, Thuy A V

    2014-05-01

    In the present study, the relationship between the turbidity of mouth-rinse water and oral health conditions, including oral malodor, in patients with (n = 148) and without (n = 231) periodontitis was examined. The turbidity of 20 mL distilled water that the patients rinsed in their mouths 10 times was measured using a turbidimeter. Oral malodor was evaluated using an organoleptic test and Oral Chroma. Oral health conditions, including decayed teeth, periodontal status, oral hygiene status, proteolytic activity of the N-benzoyl-dl-arginine-2-napthilamide (BANA) test on the tongue coating, and salivary flow rate, were assessed. Turbidity showed significant correlations with oral malodor and all oral health parameters in the periodontitis group. In the non-periodontitis group, turbidity showed significant correlations with oral malodor and oral health parameters, including dental plaque, tongue coating, BANA test, and salivary flow rate. The regression analysis indicated that turbidity was significantly associated with methyl mercaptan and the BANA test in the periodontitis group, and with hydrogen sulfide, dental plaque, tongue coating, and salivary flow rate in the non-periodontitis group. The findings of the present study indicate that the turbidity of mouth-rinse water could be used as an indicator of oral health conditions, including oral malodor. © 2013 Wiley Publishing Asia Pty Ltd.

  9. Numerical investigation of coalescing plate system to understand the separation of water and oil in water treatment plant of petroleum industry

    Directory of Open Access Journals (Sweden)

    Sedat Yayla

    2017-01-01

    Full Text Available The most widely utilized process of produced water treatment is considered to be use of coalescing or corrugated plate systems in the oil industry because these systems have promising results in the acceleration of the separation process. Even use of corrugated plate systems seem to be effective in separation processes, the geometrical parameters of the plate system could greatly influence the performance of separation process. In this study, a two-dimensional computational fluid dynamics model for coalescing plates was developed to investigate Reynolds number and plate hole shape on separation efficiency. Spacing between plates was set to 12 mm while fluid mixture’s Reynolds number varied between 5 and 45 for the computational model. Hole profile and dimensions were determined to be cylindrical, rectangular and ellipse shapes as 10, 15 and 20 mm based on hydraulic diameter definition, respectively. Furthermore, when hole profiles of coalescing plates were chosen to be ellipse and rectangular shapes, separation efficiency nearly stayed constant regardless of hole dimension. The study also reported that change of oil fraction from 5% to 15% caused approximately 30% increase in the separation efficiency. The investigation also revealed Reynolds number of the mixture was inversely proportional to the separation efficiency. It was also found that the highest separation efficiency was obtained for a cylindrical shape with a hole diameter of 15 mm when distance between plates was 12 mm and Reynolds number was 18.

  10. Note: Influence of rinsing and drying routines on growth of multilayer thin films using automated deposition system.

    Science.gov (United States)

    Gamboa, Daniel; Priolo, Morgan A; Ham, Aaron; Grunlan, Jaime C

    2010-03-01

    A versatile, high speed robot for layer-by-layer deposition of multifunctional thin films, which integrates concepts from previous dipping systems, has been designed with dramatic improvements in software, positioning, rinsing, drying, and waste removal. This system exploits the electrostatic interaction of oppositely charged species to deposit nanolayers (1-10 nm thick) from water onto the surface of a substrate. Dip times and number of deposited layers are adjustable through a graphical user interface. In between dips the system spray rinses and dries the substrate by positioning it in the two-tiered rinse-dry station. This feature significantly reduces processing time and provides the flexibility to choose from four different procedures for rinsing and drying. Assemblies of natural montmorillonite clay and polyethylenimine are deposited onto 175 microm poly(ethylene terephthalate) film to demonstrate the utility of this automated deposition system. By altering the type of rinse-dry procedure, these clay-based assemblies are shown to exhibit variations in film thickness and oxygen transmission rate. This type of system reproducibly deposits films containing 20 or more layers and may also be useful for other types of coatings that make use of dipping.

  11. Pathogenic features of heterotrophic plate count bacteria from drinking-water boreholes.

    Science.gov (United States)

    Horn, Suranie; Pieters, Rialet; Bezuidenhout, Carlos

    2016-12-01

    Evidence suggests that heterotrophic plate count (HPC) bacteria may be hazardous to humans with weakened health. We investigated the pathogenic potential of HPC bacteria from untreated borehole water, consumed by humans, for: their haemolytic properties, the production of extracellular enzymes such as DNase, proteinase, lipase, lecithinase, hyaluronidase and chondroitinase, the effect simulated gastric fluid has on their survival, as well as the bacteria's antibiotic-susceptible profile. HuTu-80 cells acted as model for the human intestine and were exposed to the HPC isolates to determine their effects on the viability of the cells. Several HPC isolates were α- or β-haemolytic, produced two or more extracellular enzymes, survived the SGF treatment, and showed resistance against selected antibiotics. The isolates were also harmful to the human intestinal cells to varying degrees. A novel pathogen score was calculated for each isolate. Bacillus cereus had the highest pathogen index: the pathogenicity of the other bacteria declined as follows: Aeromonas taiwanensis > Aeromonas hydrophila > Bacillus thuringiensis > Alcaligenes faecalis > Pseudomonas sp. > Bacillus pumilus > Brevibacillus sp. > Bacillus subtilis > Bacillus sp. These results demonstrated that the prevailing standards for HPCs in drinking water may expose humans with compromised immune systems to undue risk.

  12. Flow Regimes of Air-Water Counterflow Through Cross Corrugated Parallel Plates

    Energy Technology Data Exchange (ETDEWEB)

    de Almeida, V.F.

    2000-06-07

    Heretofore unknown flow regimes of air-water counterflow through a pair of transparent vertical parallel cross corrugated plates were observed via high-speed video. Air flows upward driven by pressure gradient and water, downward driven by gravity. The crimp geometry of the corrugations was drawn from typical corrugated sheets used as filling material in modern structured packed towers. Four regimes were featured, namely, rivulet, bicontinuous, flooding fronts, and flooding waves. It is conceivable that the regimes observed might constitute the basis for understanding how gas and liquid phases contend for available space in the interstices of structured packings in packed towers. Flow regime transitions were expressed in terms of liquid load (liquid superficial velocity) and gas flow factor parameters commonly used in pressure drop and capacity curves. We have carefully examined the range of parameters equivalent to the ill-understood high-liquid-flow operation in packed towers. More importantly, our findings should prove valuable in validating improved first-principles modeling of gas-liquid flows in these industrially important devices.

  13. Water and Electricity Do Mix: Studying Plates, Petroleum, and Permafrost using Marine Electromagnetism

    Science.gov (United States)

    Constable, S.

    2015-12-01

    Marine magnetotelluric (MT) and controlled-source electromagnetic (CSEM) sounding methods were developed in the early 1980's as deep-water academic tools to study the oceanic lithosphere and mantle. Electrical conductivity is a strong function of porosity, temperature, melting, and volatile content, and so marine MT and CSEM data can be used to address a variety of geological questions related to plate tectonics. These include the distribution of melt at mid-ocean ridges, the fate of fluids in subduction zones, and the nature of the lithosphere-asthenosphere boundary. With the advent of deepwater oil and gas drilling in the late 1990's, marine EM methods were embraced by the exploration community, and are now routinely used to assist in exploration and make drilling decisions for wells costing $100M or more. For countries without conventional hydrocarbon resources, gas hydrate offers the potential for energy production, and marine CSEM methods may be the only effective way to explore for and characterize this resource. The use of EM methods to map geothermal, groundwater, and mineral resources also has application in the marine environment. Water and electricity has proved to be a very successful mix!

  14. Performance of a LiBr-water absorption chiller operating with plate heat exchangers

    International Nuclear Information System (INIS)

    Vega, M. de; Almendros-Ibanez, J.A.; Ruiz, G.

    2006-01-01

    This paper studies the performance of a lithium bromide-water absorption chiller operating with plate heat exchangers (PHE). The overall heat transfer coefficients in the desorber, the condenser and the solution heat recoverer are calculated using the correlations provided in the literature for evaporation, condensation and liquid to liquid heat transfer in PHEs. The variable parameters are the external driving temperatures. In the desorber, the inlet temperature of the hot fluid ranges from 75 deg. C to 105 deg. C. In the condenser and the absorber, the inlet temperature of the cooling water goes from 20 deg. C to 40 deg. C. The coefficient of performance (COP) obtained ranges from 0.5 to 0.8 for cooling duties ranging from 2 kW to 12 kW. The chiller response to different hot fluid temperatures and circulated mass flow rates is also presented. The performance and the internal parameters of the chiller at part load are, therefore, calculated. A higher efficiency results when the solution pumped from the absorber to the desorber decreases. The heat transfer analysis of the PHEs is also presented. The overall heat transfer coefficient in the desorber, equal to 790 W/m 2 K at the design conditions, is also analysed at part load. The condenser performance can be represented by a similar relationship found in conventional air cooled condensers

  15. Effects of a non-rinse conditioner on the enamel of primary teeth

    Directory of Open Access Journals (Sweden)

    Fava Marcelo

    2003-01-01

    Full Text Available The aim of this in vitro study was to evaluate by scanning electron microscopy the morphological aspects of the enamel of primary teeth after etching with 36% phosphoric acid or a non-rinse conditioner. Ten naturally exfoliated anterior primary teeth were selected. The samples were subjected to prophylaxis with pumice paste and water using a low-speed hand piece. Etching was done on the buccal surface. Specimens were divided into 2 groups: G1 (n=10: etching with 36% phosphoric acid gel - Conditioner 36 (Dentsply for 20 s, followed by water rinse for 15 s; G2 (n=10: etching with NRC - Non Rinse Conditioner (Dentsply for 20 s, followed by air drying for 15 s. The samples were dehydrated, mounted on metal stubs, coated with gold and observed with Jeol JSM-6100 scanning electron microscope. Electron-micrographic analysis showed that both etching agents were effective for etching the enamel of primary teeth causing the formation of microporosities on the enamel surface, although the etching pattern was more effective with the use of 36% phosphoric acid gel.

  16. CFD modelling of axial mixing in the intermediate and final rinses of cleaning-in-place procedures of straight pipes

    DEFF Research Database (Denmark)

    Yang, Jifeng; Jensen, Bo Boye Busk; Nordkvist, Mikkel

    2018-01-01

    The intermediate and final rinses of straight pipes, in which water replaces a cleaning agent of similar density and viscosity, are modelled using Computational Fluid Dynamic (CFD) methods. It is anticipated that the displacement process is achieved by convective and diffusive transport. The simu...

  17. In vitro study of the effect of an essential oil and a delmopinol mouth rinse on dental plaque bacteria.

    Science.gov (United States)

    LuIs, Henrique Soares; Luis, Luis Soares; Bernardo, Mário

    2016-01-01

    Mouthrinses are used, by many of our patients, as a complement to daily dental hygiene routine. The use of a toothbrush and an interproximal cleaning method may not be enough to control dental plaque. Essential oils and delmopinol mouth rinses are effective for the prevention of dental caries and gingivitis. To study the effect of an essential oil and a delmopinol mouth rinse on dental plaque bacteria, an in vitro study was developed. The objective of this study was to determine the antibacterial activity of an essential oil and a delmopinol mouth rinse on Streptococcus mutans, Lactobacilli, and aerobic and anaerobic dental plaque nonspecific bacteria. Samples of human dental plaque were collected from consenting participants and bacteria isolated. Disk-diffusion tests were performed to obtain the minimum concentration of the mouth rinses necessary to inhibit bacterial growth. The ability of the commercial mouth rinses to inhibit bacterial growth was studied in comparison to a positive control (0.2% chlorhexidine) and a negative laboratorial control (sterilized water). The minimum inhibitory concentration was found to be inferior to the commercial essential oils and delmopinol mouth rinses concentrations. Delmopinol and essential oils have significant antibacterial properties shown in vitro only for aerobic bacteria, and for S. mutans, Lactobacillus, and anaerobic bacteria, the results were not statistically significant. Essential oils and chlorhexidine are statistically similar and better than delmopinol for aerobic bacteria growth inhibition. For the other bacteria, essential oils and delmopinol are not statistically promising. Results show that essential oils only may help patients to maintain good oral health as a complement to daily brushing and interproximal cleaning.

  18. Experimental results of the consequences of sodium water reactions at the bottom tube plate region of straight tube steam generators

    International Nuclear Information System (INIS)

    Ruloff, G.

    1990-01-01

    Experience with sodium water reactions has shown, that the course of such a steam generator accident depends strongly on its place in the steam generator. For the EFR steam generators we have to differentiate between: weld region at the upper tube plate (gas space); bundle region; weld region at the bottom tube plate. This paper describes results of a running tests program simulating the bottom tube plate area. One main part of these tests is the investigation of the influence of wastage protection shrouds between the tubes in the weld region to avoid a fast leak propagation and to give time for leak detection and mastering of the accidents. (author). 10 figs, 2 tabs

  19. Effectiveness of immediate bonding of etch-and-rinse adhesives to simplified ethanol-saturated dentin

    Directory of Open Access Journals (Sweden)

    Leandro Afonso Guimarães

    2012-04-01

    Full Text Available This study examined the immediate bond strength of etch-and-rinse adhesives to demineralized dentin saturated with either water or absolute ethanol. The research hypothesis was that there would be no difference in bond strength to dentin between water or ethanol wet-bonding techniques. The medium dentin of 20 third molars was exposed (n = 5. The dentin surface was then acid-etched, left moist and randomly assigned to be saturated via either water wet-bonding (WBT or absolute ethanol wet-bonding (EBT. The specimens were then treated with one of the following etch-and-rinse adhesive systems: a 3-step, water-based system (Adper Scotchbond Multipurpose, or SBMP or a 2-step, ethanol/water-based system (Adper Single Bond 2, or SB. Resin composite build-ups were then incrementally constructed. After water storage for 24 h at 37°C, the tensile strength of the specimens was tested in a universal testing machine (0.5 mm/min. Data were analyzed by two-way ANOVA and Tukey's test (a = 5%. The failure modes were verified using a stereomicroscope (40'. For both adhesives, no significant difference in bond strength was observed between WBT and EBT (p > 0.05. The highest bond strength was observed for SB, regardless of the bonding technique (p < 0.05. No significant interaction between adhesives and bonding techniques was noticed (p = 0.597. There was a predominance of adhesive failures for all tested groups. The EBT and WBT displayed similar immediate bond strength means for both adhesives. The SB adhesive exhibited higher means for all conditions tested. Further investigations are needed to evaluate long-term bonding to dentin mediated by commercial etch-and-rinse adhesives using the EBT approach.

  20. Oral Topical Doxepin Rinse: Anesthetic Effect in Normal Subjects

    Directory of Open Access Journals (Sweden)

    Joel B Epstein

    2003-01-01

    Full Text Available Oral doxepin rinse has been reported to provide pain relief in patients with oral mucosal lesions due to cancer or cancer therapy. The purpose of this study was to assess the anesthetic effect of doxepin oral rinse in normal subjects to identify the duration of effect and to contrast the anesthetic effect with reported pain relief in patients with oral mucosal lesions. Normal volunteers were provided a solution of doxepin (5 mg/mL for oral rinsing. Oral numbness and adverse effects were recorded for a period of 4 h after rinsing. Doxepin rinse resulted in mucosal anesthesia in all subjects. Sedation/fatigue was reported in four of seven subjects. There were no taste complaints and no nausea reported. The limited duration of numbness/anesthesia in normal subjects compared with prior studies showing pain relief for more than 3 h in patients with mucosal lesions, suggests that the extended duration of pain relief in patients was due to analgesic effects rather than anesthetic effects. The majority of normal subjects reported sedation after use, but this was less common in patients with mucosal lesions.

  1. Validation of a hot water rinse and lactic acid spray in combination with scaling for treating hide-on carcasses to control biotype I strains of Escherichia coli used as surrogates for Shiga toxin-producing E. coli

    Science.gov (United States)

    Scalding of hide-on bob veal carcasses with or without standard scalding chemical agents typically used for hogs, followed by an 82.2degreeC hot water wash and lactic acid spray (applied at ambient temperature) prior to chilling, was evaluated to determine its effectiveness in reducing the levels of...

  2. Longevity of Self-etch Dentin Bonding Adhesives Compared to Etch-and-rinse Dentin Bonding Adhesives: A Systematic Review.

    Science.gov (United States)

    Masarwa, Nader; Mohamed, Ahmed; Abou-Rabii, Iyad; Abu Zaghlan, Rawan; Steier, Liviu

    2016-06-01

    A systematic review and meta-analysis were performed to compare longevity of Self-Etch Dentin Bonding Adhesives to Etch-and-Rinse Dentin Bonding Adhesives. The following databases were searched for PubMed, MEDLINE, Web of Science, CINAHL, the Cochrane Library complemented by a manual search of the Journal of Adhesive Dentistry. The MESH keywords used were: "etch and rinse," "total etch," "self-etch," "dentin bonding agent," "bond durability," and "bond degradation." Included were in-vitro experimental studies performed on human dental tissues of sound tooth structure origin. The examined Self-Etch Bonds were of two subtypes; Two Steps and One Step Self-Etch Bonds, while Etch-and-Rinse Bonds were of two subtypes; Two Steps and Three Steps. The included studies measured micro tensile bond strength (μTBs) to evaluate bond strength and possible longevity of both types of dental adhesives at different times. The selected studies depended on water storage as the aging technique. Statistical analysis was performed for outcome measurements compared at 24 h, 3 months, 6 months and 12 months of water storage. After 24 hours (p-value = 0.051), 3 months (p-value = 0.756), 6 months (p-value=0.267), 12 months (p-value=0.785) of water storage self-etch adhesives showed lower μTBs when compared to the etch-and-rinse adhesives, but the comparisons were statistically insignificant. In this study, longevity of Dentin Bonds was related to the measured μTBs. Although Etch-and-Rinse bonds showed higher values at all times, the meta-analysis found no difference in longevity of the two types of bonds at the examined aging times. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Experimental study of a water-mist jet issuing normal to a heated flat plate

    Directory of Open Access Journals (Sweden)

    Vouros Andreas

    2016-01-01

    Full Text Available A parametric experimental study on the development of a round jet spray impacting a smooth, heated, flat plate has been accomplished. The main objective of this effort was to provide information characterizing the flow structure of a developing mist jet, issuing vertically towards an upward facing, horizontal heated plate, by means of simultaneous droplet size and velocity measurements. Phase Doppler Anemometry was used, providing also information on liquid volume flux. The fine spray of small atomized droplets (0.5-5.0 μm, was generated using a medical nebulizer. Two low Reynolds number jets (Re=2952, 3773 issuing from a cylindrical pipe have been tested. The distance between the jets’ exit and the plate was 50 cm. A stainless steel non-magnetic flat plate of dimensions 1000x500x12mm3 was used as target wall. Constant heat flux boundary conditions were established during measurements. Results indicate that the heat flux from the plate is influencing the evolution of the spray jet, diminishing its velocity and turbulence. Average droplet sizes are affected little by the heat flux, although for the non-heated sprays, droplet sizes increase at locations very close to the plate. A significant effect on droplet volume flow rate is also reported.

  4. Research and Development of Heavy Wall DNV485FDU Pipeline Plate for 3500M Deep Water Pipe Applications at Shougang

    Science.gov (United States)

    Ding, Wenhua; Li, Shaopo; Li, Jiading; Li, Qun; Chen, Tieqiang; Zhang, Hai

    In recent years, there has been development of several significant pipeline projects for the transmission of oil and gas from deep water environments. The production of gas transmission pipelines for application demands heavy wall, high strength, good lower temperature toughness and good weldability. To overcome the difficulty of producing consistent mechanical property in heavy wall pipe Shougang Steel Research in cooperation with the Shougang Steel Qinhuangdao China (Shouqin) 4.3m heavy wide plate mill research was conducted.

  5. PERFORMANCE DETERIORATION OF THERMOSIPHON SOLAR FLAT PLATE WATER HEATER DUE TO SCALING

    Directory of Open Access Journals (Sweden)

    arunachala umesh chandavar

    2011-12-01

    Full Text Available 0 0 1 340 1943 International Islamic University 16 4 2279 14.0 Normal 0 false false false EN-US JA X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Times New Roman";} The performance of Flat plate Solar Water Heater deteriorates within five to twelve years of their installation due to factors related to manufacturing, operating conditions, lack of maintenance etc. Especially, problem due to scaling is significant as it is based on quality of water used. The remaining factors are system dependent and could be overcome by quality production. Software is developed by incorporating Hottel Whillier Bliss (H-W-B equation to ascertain the effect of scaling on system efficiency in case of thermosiphon system. In case of clean thermosiphon system, the instantaneous efficiency calculated at 1000 W/m2 radiation is 72 % and it drops to 46 % for 3.7 mm scale thickness. The mass flow rate is reduced by 90 % for 3.7 mm scale thickness. Whereas, the average temperature drop of water in the tank is not critical due to considerable heat content in water under severe scaled condition.  But practically in case of major scale growth, some of the risers are likely to get blocked completely which leads to negligible temperature rise in the tank. ABSTRAK: Prestasi plat rata pemanas air suria merosot selepas lima hingga dua belas tahun  pemasangannya disebabkan faktor-faktor yang berkaitan dengan pembuatannya, cara kendaliannya, kurangnya penyelenggaraan dan sebagainya.  Terutama sekali, masalah disebabkan scaling (tembunan endapan mineral perlu diambil berat kerana ianya bergantung kepada kualiti air yang digunakan. Faktor-faktor selebihya bersandarkan sistem dan ia

  6. Comparison of plate counts, Petrifilm, dipslides, and adenosine triphosphate bioluminescence for monitoring bacteria in cooling-tower waters.

    Science.gov (United States)

    Mueller, Sherry A; Anderson, James E; Kim, Byung R; Ball, James C

    2009-04-01

    Effective bacterial control in cooling-tower systems requires accurate and timely methods to count bacteria. Plate-count methods are difficult to implement on-site, because they are time- and labor-intensive and require sterile techniques. Several field-applicable methods (dipslides, Petrifilm, and adenosine triphosphate [ATP] bioluminescence) were compared with the plate count for two sample matrices--phosphate-buffered saline solution containing a pure culture of Pseudomonas fluorescens and cooling-tower water containing an undefined mixed bacterial culture. For the pure culture, (1) counts determined on nutrient agar and plate-count agar (PCA) media and expressed as colony-forming units (CFU) per milliliter were equivalent to those on R2A medium (p = 1.0 and p = 1.0, respectively); (2) Petrifilm counts were not significantly different from R2A plate counts (p = 0.99); (3) the dipslide counts were up to 2 log units higher than R2A plate counts, but this discrepancy was not statistically significant (p = 0.06); and (4) a discernable correlation (r2 = 0.67) existed between ATP readings and plate counts. For cooling-tower water samples (n = 62), (1) bacterial counts using R2A medium were higher (but not significant; p = 0.63) than nutrient agar and significantly higher than tryptone-glucose yeast extract (TGE; p = 0.03) and PCA (p < 0.001); (2) Petrifilm counts were significantly lower than nutrient agar or R2A (p = 0.02 and p < 0.001, respectively), but not statistically different from TGE, PCA, and dipslides (p = 0.55, p = 0.69, and p = 0.91, respectively); (3) the dipslide method yielded bacteria counts 1 to 3 log units lower than nutrient agar and R2A (p < 0.001), but was not significantly different from Petrifilm (p = 0.91), PCA (p = 1.00) or TGE (p = 0.07); (4) the differences between dipslides and the other methods became greater with a 6-day incubation time; and (5) the correlation between ATP readings and plate counts varied from system to system, was poor

  7. Effect of a 5000 ppm fluoride toothpaste and a 250 ppm fluoride mouth rinse on the demineralisation of dentin surfaces.

    Science.gov (United States)

    Bizhang, Mozhgan; Chun, Yong-Hee P; Winterfeld, Mai-Trinh; Altenburger, Markus J; Raab, Wolfgang H M; Zimmer, Stefan

    2009-07-23

    The purpose of this study was to test the null hypothesis that there is no difference between the effect of (1) a 5000 ppm fluoride toothpaste, and (2) a 250 ppm fluoride mouth rinse on demineralized human dentin surfaces, against the alternative hypothesis of a difference. Dentin specimens were obtained from the cervical regions of 45 extracted human third molars. Half the surface of each specimen was sealed with a self-etching adhesive system and served as the reference surface. The dentin specimens were randomly assigned to one of the three groups, 5000 ppm fluoride toothpaste (Duraphat), 250 ppm fluoride mouth rinse (Meridol) and distilled water (negative control).An intraoral appliance was made for one volunteer. In each test cycle, 15 specimens were inserted in the appliance and worn for 24 hours a day, over a period of three weeks.Once daily, the appliance was immersed in the agent being tested; either toothpaste slurry, mouth rinse or distilled water for 60 seconds.Demineralization was assessed in terms of lesion depth (microm) and mineral loss (vol. % x microm) by transversal microradiography. Data analysis was accomplished using Kolmogorov-Smirnov test and ANOVA (SPSS 12.0).Statistically significant differences for mineral loss and lesion depth were found between the toothpaste and the mouth rinse as well as between the toothpaste and the control group, but not between the mouth rinse and the control group. Within the limitations of this study, the results suggest that treatment of demineralised dentin with a toothpaste containing 5000 ppm fluoride may considerably reduce mineral loss and lesion depth on exposed dentin.

  8. Introduction to Superconducting RF Structures and the Effect of High Pressure Rinsing

    Energy Technology Data Exchange (ETDEWEB)

    Tajima, Tsuyoshi [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-30

    This presentation begins by describing RF superconductivity and SRF accelerating structures. Then the use of superconducting RF structures in a number of accelerators around the world is reviewed; for example, the International Linear Collider (ILC) will use ~16,000 SRF cavities with ~2,000 cryomodules to get 500 GeV e⁺/e⁻ colliding energy. Field emission control was (and still is) a very important practical issue for SRF cavity development. It has been found that high-pressure ultrapure water rinsing as a final cleaning step after chemical surface treatment resulted in consistent performance of single- and multicell superconducting cavities.

  9. Introduction to Superconducting RF Structures and the Effect of High Pressure Rinsing

    International Nuclear Information System (INIS)

    Tajima, Tsuyoshi

    2016-01-01

    This presentation begins by describing RF superconductivity and SRF accelerating structures. Then the use of superconducting RF structures in a number of accelerators around the world is reviewed; for example, the International Linear Collider (ILC) will use ~16,000 SRF cavities with ~2,000 cryomodules to get 500 GeV e@@@/e@@@ colliding energy. Field emission control was (and still is) a very important practical issue for SRF cavity development. It has been found that high-pressure ultrapure water rinsing as a final cleaning step after chemical surface treatment resulted in consistent performance of single- and multicell superconducting cavities.

  10. Thermal-hydraulic analysis under partial loss of flow accident hypothesis of a plate-type fuel surrounded by two water channels using RELAP5 code

    OpenAIRE

    Itamar Iliuk; José Manoel Balthazar; Ângelo Marcelo Tusset; José Roberto Castilho Piqueira

    2016-01-01

    Thermal-hydraulic analysis of plate-type fuel has great importance to the establishment of safety criteria, also to the licensing of the future nuclear reactor with the objective of propelling the Brazilian nuclear submarine. In this work, an analysis of a single plate-type fuel surrounding by two water channels was performed using the RELAP5 thermal-hydraulic code. To realize the simulations, a plate-type fuel with the meat of uranium dioxide sandwiched between two Zircaloy-4 plates was prop...

  11. A caffeine-maltodextrin mouth rinse counters mental fatigue.

    Science.gov (United States)

    Van Cutsem, Jeroen; De Pauw, Kevin; Marcora, Samuele; Meeusen, Romain; Roelands, Bart

    2018-04-01

    Mental fatigue is a psychobiological state caused by prolonged periods of demanding cognitive activity that has negative implications on many aspects in daily life. Caffeine and carbohydrate ingestion have been shown to be able to reduce these negative effects of mental fatigue. Intake of these substances might however be less desirable in some situations (e.g., restricted caloric intake, Ramadan). Rinsing caffeine or glucose within the mouth has already been shown to improve exercise performance. Therefore, we sought to evaluate the effect of frequent caffeine-maltodextrin (CAF-MALT) mouth rinsing on mental fatigue induced by a prolonged cognitive task. Ten males (age 23 ± 2 years, physical activity 7.3 ± 4.3 h/week, low CAF users) performed two trials. Participants first completed a Flanker task (3 min), then performed a 90-min mentally fatiguing task (Stroop task), followed by another Flanker task. Before the start and after each 12.5% of the Stroop task (eight blocks), subjects received a CAF-MALT mouth rinse (MR: 0.3 g/25 ml CAF: 1.6g/25 ml MALT) or placebo (PLAC: 25 ml artificial saliva). Self-reported mental fatigue was lower in MR (p = 0.017) compared to PLAC. Normalized accuracy (accuracy first block = 100%) was higher in the last block of the Stroop in MR (p = 0.032) compared to PLAC. P2 amplitude in the dorsolateral prefrontal cortex (DLPFC) decreased over time only in PLAC (p = 0.017). Frequent mouth rinsing during a prolonged and demanding cognitive task reduces mental fatigue compared to mouth rinsing with artificial saliva.

  12. Synergetic effect of copper-plating wastewater as a catalyst for the destruction of acrylonitrile wastewater in supercritical water oxidation

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Young Ho; Lee, Hong-shik; Lee, Young-Ho [School of Chemical and Biological Engineering and Institute of Chemical Processes, Seoul National University, 599 Gwanangno, Gwanak-gu, Seoul 151-744 (Korea, Republic of); Kim, Jaehoon; Kim, Jae-Duck [Supercritical Fluid Research Laboratory, Energy and Environment Research Division, Korea Institute of Science and Technology (KIST), 39-1 Hawolgok-dong, Seongbuk-gu, Seoul 136-791 (Korea, Republic of); Lee, Youn-Woo, E-mail: ywlee@snu.ac.kr [School of Chemical and Biological Engineering and Institute of Chemical Processes, Seoul National University, 599 Gwanangno, Gwanak-gu, Seoul 151-744 (Korea, Republic of)

    2009-08-15

    A new supercritical water oxidation process for the simultaneous treatment of mixed wastewater containing wastewater from acrylonitrile manufacturing processes and copper-plating processes was investigated using a continuous tubular reactor system. Experiments were carried out at temperatures ranging from 400 to 600 deg. C and a pressure of 25 MPa. The residence time was fixed at 2 s by changing the flow rates of feeds, depending on reaction temperature. The initial total organic carbon (TOC) concentration of the wastewaters and the O{sub 2} concentration at the reactor inlet were kept constant at 0.49 and 0.74 mol/L. It was confirmed that the copper-plating wastewater accelerated the TOC conversion of acrylonitrile wastewater from 17.6% to 67.3% at a temperature of 450 deg. C. Moreover, copper and copper oxide nanoparticles were generated in the process of supercritical water oxidation (SCWO) of mixed wastewater. 99.8% of copper in mixed wastewater was recovered as solid copper and copper oxides at a temperature of 600 deg. C, with their average sizes ranging from 150 to 160 nm. Our study showed that SCWO provides a synergetic effect for simultaneous treatment of acrylonitrile and copper-plating wastewater. During the reaction, the oxidation rate of acrylonitrile wastewater was enhanced due to the in situ formation of nano-catalysts of copper and/or copper oxides, while the exothermic decomposition of acrylonitrile wastewater supplied enough heat for the recovery of solid copper and copper oxides from copper-plating wastewater. The synergetic effect of wastewater treatment by the newly proposed SCWO process leads to full TOC conversion, color removal, detoxification, and odor elimination, as well as full recovery of copper.

  13. 21 CFR 872.5580 - Oral rinse to reduce the adhesion of dental plaque.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Oral rinse to reduce the adhesion of dental plaque... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Therapeutic Devices § 872.5580 Oral rinse to reduce the adhesion of dental plaque. (a) Identification. The device is assigned the generic name oral rinse to reduce...

  14. Thermal-hydraulic analysis under partial loss of flow accident hypothesis of a plate-type fuel surrounded by two water channels using RELAP5 code

    Directory of Open Access Journals (Sweden)

    Itamar Iliuk

    2016-01-01

    Full Text Available Thermal-hydraulic analysis of plate-type fuel has great importance to the establishment of safety criteria, also to the licensing of the future nuclear reactor with the objective of propelling the Brazilian nuclear submarine. In this work, an analysis of a single plate-type fuel surrounding by two water channels was performed using the RELAP5 thermal-hydraulic code. To realize the simulations, a plate-type fuel with the meat of uranium dioxide sandwiched between two Zircaloy-4 plates was proposed. A partial loss of flow accident was simulated to show the behavior of the model under this type of accident. The results show that the critical heat flux was detected in the central region along the axial direction of the plate when the right water channel was blocked.

  15. The effect of daily fluoride mouth rinsing on enamel erosive/abrasive wear in situ.

    Science.gov (United States)

    Stenhagen, K R; Hove, L H; Holme, B; Tveit, A B

    2013-01-01

    It is not known whether application of fluoride agents on enamel results in lasting resistance to erosive/abrasive wear. We investigated if one daily mouth rinse with sodium fluoride (NaF), stannous fluoride (SnF(2)) or titanium tetrafluoride (TiF(4)) solutions protected enamel against erosive/abrasive wear in situ (a paired, randomised and blind study). Sixteen molars were cut into 4 specimens, each with one amalgam filling (measurement reference surface). Two teeth (2 × 4 specimens) were mounted bilaterally (buccal aspects) on acrylic mandibular appliances and worn for 9 days by 8 volunteers. Every morning, the specimens were brushed manually with water (30 s) extra-orally. Then fluoride solutions (0.4% SnF(2) pH 2.5; 0.15% TiF(4) pH 2.1; 0.2% NaF pH 6.5, all 0.05 M F) were applied (2 min). Three of the specimens from each tooth got different treatment, and the fourth served as control. At midday, the specimens were etched for 2 min in 300 ml fresh 0.01 M hydrochloric acid and rinsed in tap water. This etch procedure was repeated in the afternoon. Topographic measurements were performed by a white-light interferometer. Mean surface loss (±SD) for 16 teeth after 9 days was: SnF(2) 1.8 ± 1.9 µm, TiF(4) 3.1 ± 4.8 µm, NaF 26.3 ± 4.7 µm, control 32.3 ± 4.4 µm. Daily rinse with SnF(2), TiF(4) and NaF resulted in 94, 90 and 18% reduction in enamel erosive/abrasive wear, respectively, compared with control (p < 0.05). The superior protective effect of daily rinse with either stannous or titanium tetrafluoride solutions on erosive/abrasive enamel wear is promising. Copyright © 2012 S. Karger AG, Basel.

  16. Antibiotic resistance in triclosan heterotrophic plate count bacteria from sewage water / Ilsé Coetzee

    OpenAIRE

    Coetzee, Ilsé

    2015-01-01

    The concentration of triclosan in antiseptics, disinfectants and preservatives in products exceeds the minimal lethal levels. Extensive use of triclosan and antibiotics results in bacterial resistance to their active ingredients. The precise relationship between use and resistance, however, has been challenging to define. The aim of the study was to identify and determine antibiotic resistance profiles of triclosan tolerant heterotrophic plate count bacteria isolates from sewag...

  17. Experimental study on depth of paraffin wax over floating absorber plate in built-in storage solar water heater

    Directory of Open Access Journals (Sweden)

    R Sivakumar

    2015-11-01

    Full Text Available The aim of this article is to study the effect of depth of phase change material over the absorber surface of an integrated collector-storage type flat plate solar water heater. Flat plate solar water heaters are extensively used all over the world to utilize the natural source of solar energy. In order to utilize the solar energy during off-sunshine hours, it is inevitable to store and retain solar thermal energy as long as possible. Here, phase change material is not used for heat storage, but to minimize losses during day and night time only. The depth of phase change material over a fixed depth of water in a solar thermal collector is an important geometric parameter that influences the maximum temperature rise during peak solar irradiation and hence the losses. From the results of the studies for different masses of paraffin wax phase change material layers, the optimum depth corresponding to the maximum heat gain till evening is found to be 2 mm, and the heat retention till the next day morning is found to be 4 mm.

  18. Erosion protection by calcium lactate/sodium fluoride rinses under different salivary flows in vitro.

    Science.gov (United States)

    Borges, Alessandra B; Scaramucci, Taís; Lippert, Frank; Zero, Domenick T; Hara, Anderson T

    2014-01-01

    This study investigated the effect of a calcium lactate prerinse on sodium fluoride protection in an in vitro erosion-remineralization model simulating two different salivary flow rates. Enamel and dentin specimens were randomly assigned to 6 groups (n = 8), according to the combination between rinse treatments - deionized water (DIW), 12 mM NaF (NaF) or 150 mM calcium lactate followed by NaF (CaL + NaF) - and unstimulated salivary flow rates - 0.5 or 0.05 ml/min - simulating normal and low salivary flow rates, respectively. The specimens were placed into custom-made devices, creating a sealed chamber on the specimen surface connected to a peristaltic pump. Citric acid was injected into the chamber for 2 min, followed by artificial saliva (0.5 or 0.05 ml/min) for 60 min. This cycle was repeated 4×/day for 3 days. Rinse treatments were performed daily 30 min after the 1st and 4th erosive challenges, for 1 min each time. Surface loss was determined by optical profilometry. KOH-soluble fluoride and structurally bound fluoride were determined in specimens at the end of the experiment. Data were analyzed by 2-way ANOVA and Tukey tests (α = 0.05). NaF and CaL + NaF exhibited significantly lower enamel and dentin loss than DIW, with no difference between them for normal flow conditions. The low salivary flow rate increased enamel and dentin loss, except for CaL + NaF, which presented overall higher KOH-soluble and structurally bound fluoride levels. The results suggest that the NaF rinse was able to reduce erosion progression. Although the CaL prerinse considerably increased F availability, it enhanced NaF protection against dentin erosion only under hyposalivatory conditions.

  19. Methyldibromoglutaronitrile in rinse-off products causes allergic contact dermatitis

    DEFF Research Database (Denmark)

    Jensen, C D; Johansen, J D; Menné, T

    2004-01-01

    BACKGROUND: The frequency of sensitivity to the cosmetic preservative methyldibromoglutaronitrile (MDBGN) has increased significantly in Europe. Most cases of allergic contact dermatitis from MDBGN are caused by leave-on cosmetic products. The risk of developing allergic contact dermatitis from...... series of MDBGN to determine their patch test threshold values. RESULTS: Seven presensitized individuals (37%) developed allergic contact dermatitis from the soap containing MDBGN. The mean dose of MDBGN per application was 2.2 micro g cm-2 and the reactions appeared between days 6 and 34. All nine...... rinse-off products has been less studied. OBJECTIVES: To investigate the allergic response elicited in presensitized individuals from exposure to a rinse-off product preserved with the maximum permitted level of MDBGN. METHODS: Nineteen contact allergic individuals and nine controls participated...

  20. Carbohydrate mouth rinse does not improve repeated sprint performance

    Directory of Open Access Journals (Sweden)

    Leandro Ricardo Altimari

    2013-09-01

    Full Text Available The objective of this study was to evaluate the effect of a carbohydrate mouth rinse on the repeated sprint ability (RSA of young soccer players. Nine youth soccer players (15.0 ± 1.5 years; 60.7 ± 4.84 kg; 1.72 ± 0.05 m; 20.5 ± 1.25 kg/m2 were selected. The athletes were submitted to an RSA test consisting of six sprints of 40 m (going/return = 20 m + 20 m, separated by 20 s of passive recovery, under three experimental conditions: carbohydrate mouth rinse (CHO or placebo (PLA and control (CON. The mouth rinses containing CHO or PLA were administered 5 min and immediately before the beginning of the test in doses of 100 mL. The best sprint time (RSAbest, mean sprint time (RSAmean, and drop-off in sprint performance (fatigue index were determined for the different treatments. One-not identify significant differences (p> 0.05 in RSAbest (CHO way ANOVA for repeated measures did = 7.30 ± 0.31 s; PLA = 7.30 ± 0.30 s; CON = 7.26 ±0.16 s, RSA mean (CHO = 7.71 ± 0.30 s; PLA = 7.71 ± 0.25 s; CON = 7.66 ± 0.24s, or fatigue index (CHO = 5.58 ± 2.16%; PLA = 5.77 ± 3.04%; CON = 5.55 ±3.72%. The results suggest that a carbohydrate mouth rinse does not improve the repeated sprint performance of young soccer players.

  1. Effect of various rinsing protocols after use of amine fluoride/stannous fluoride toothpaste on the bacterial composition of dental plaque.

    Science.gov (United States)

    van Loveren, C; Gerardu, V A M; Sissons, C H; van Bekkum, M; ten Cate, J M

    2009-01-01

    This clinical study evaluated the effect of different oral hygiene protocols on the bacterial composition of dental plaque. After a 2-week period of using fluoride-free toothpaste, 30 participants followed three 1-week experimental protocols, each followed by 2-week fluoride-free washout periods in a randomized crossover examiner-blind controlled trial. The 1-week experimental protocols comprised the use of AmF/SnF(2) toothpaste twice daily, after which participants either (1) rinsed with tap water, (2) did not rinse but only spat out the toothpaste, or (3) rinsed with an AmF/SnF(2) mouthwash. In the fluoride-free washout periods, the participants brushed their teeth with fluoride-free toothpaste without further instructions. Six hours after the last brushing (+/- rinsing) of each period, buccal plaque samples in the upper molar region were taken. The microbiota composition of the plaque samples was analyzed by checkerboard DNA:DNA hybridization. A statistically significant reduction was found in the total amount of DNA of the 39 major plaque species measured, and in the proportions of some acid-producing bacterial strains after the period having used the AmF/SnF(2) toothpaste + AmF/SnF(2) mouthrinsing. The results indicate that using the AmF/SnF(2) toothpaste and rinse combination could result in plaque of lower cariogenicity. Copyright 2009 S. Karger AG, Basel.

  2. An experimental study of the mass flow rates effect on flat-plate solar water heater performance using Al2O3/water nanofluid

    Directory of Open Access Journals (Sweden)

    Prakasam Michael Joseph Stalin

    2017-01-01

    Full Text Available In the present work, flat plate solar water heating system has been designed and fabricated accommodating 2 m2 area of solar collector and 0.12 m2 surface area of the heat exchanger using Al2O3/water nanofluid as the working fluid in order to evaluate the performance efficiency in the forced circulation mode. The instantaneous efficiency of solar collector is calculated by taking lower volume fraction of 0.01% with average particle size of 25 nm with and without Triton X-100 surfactant and varying the flow rate from 1 L per minute to 3 L per minute, as per ASHRAE standard. The experimental results show that utilizing Al2O3/water nanofluid with mass flow rate at 2 L per minute increases the collector efficiency by 14.3% when compared to distilled water as the working medium.

  3. Comparison of the Streptococcus mutans and Lactobacillus colony count changes in saliva following chlorhexidine (0.12% mouth rinse, combination mouth rinse, and green tea extract (0.5% mouth rinse in children

    Directory of Open Access Journals (Sweden)

    Rahul J Hegde

    2017-01-01

    Full Text Available Background: Compounds present in green tea have been shown to inhibit the growth and activity of bacteria associated with oral infections. The purpose of this study was to compare the efficacy of chlorhexidine (0.12% mouth rinse and combination (chlorhexidine and sodium fluoride mouth rinse to that of green tea extract (0.5% mouth rinse in reducing the salivary count of Streptococcus mutans and Lactobacillus in children. Materials and Methods: The sample for the study consisted of 75 school children aged 8–12 years with four or more (decay component of decayed, missing, and filled teeth index. Children were divided randomly into three equal groups and were asked to rinse with the prescribed mouth rinse once daily for 2 weeks after breakfast under supervision. Nonstimulated whole salivary sample (2 ml was collected at baseline and postrinsing and tested for the colony forming units of S. mutans and Lactobacillus. Results: The results of the study indicate that there was a statistically significant reduction in S. mutans and lactobacilli count in all the three study groups. The statistically significant reduction in the mean S. mutans and lactobacilli counts were more in 0.12% chlorhexidine group than in the combination mouth rinse and 0.5% green tea mouth rinse group. There was no statistically significant difference in the reduction of S. mutans and lactobacilli count between combination mouth rinse group and 0.5% green tea mouth rinse group. Conclusion: Green tea mouth rinse can be a promising preventive therapy worldwide for the prevention of dental caries.

  4. Measurement of tritium activity in the aluminum pipe of JRR-2 heavy water primary cooling system using imaging plate

    International Nuclear Information System (INIS)

    Motoishi, Shoji; Kobayashi, Katsutoshi

    2000-12-01

    JRR-2 is the heavy water cooling type nuclear reactor, which has been operated for 36 years (1960-1976) and in the process of decommissioning at present. For this reason, evaluation of tritium quantity permeated into the pipe and apparatus of the primary coolant heavy water circulating system is important. In the Radioisotope Production Division, activity of tritium in aluminum pipe was measured with imaging plate (IP), liquid scintillation analyzer and high purity germanium detector (HPGe). After acrylic paints was applied for the region except for tritium contamination on the surface of aluminum pipe, only the oxidized contaminated part was dissolved by 1.5%(1.21M) HF for 3 minutes, and measured with IP. As a result, the tritium was found to permeate in the depth of 25 μm. Moreover, 90% of it was found to be distributed within 7 μm. (author)

  5. Unsteady free convection flow past a semi-infinite vertical plate with constant heat flux in water based nanofluids

    Science.gov (United States)

    Narahari, Marneni

    2018-04-01

    The unsteady free convective flow of nanofluids past a semi-infinite vertical plate with uniform heat flux has been investigated numerically. An implicit finite difference technique of Crank-Nicolson scheme has been employed to solve the governing partial differential equations. Five different types of water based nanofluids containing Cu, Ag, Al2O3, CuO and TiO2 nanoparticles are considered to study the fluid flow characteristics with various time and solid volume fraction parameters. It is found that the local as well as the average Nusselt number for nanofluids is higher than the pure fluid (water). The local skin-friction is higher for pure fluid as compared to the nanofluids. The present numerical results obtained for local Nusselt number are validated with the previously published correlation results for a limiting case and it is found that the results are in good agreement.

  6. Treatment of shelter cats with oral terbinafine and concurrent lime sulphur rinses.

    Science.gov (United States)

    Moriello, Karen; Coyner, Kimberly; Trimmer, Ann; Newbury, Sandra; Kunder, Darcie

    2013-12-01

    Dermatophytosis is an important contagious and infectious skin disease in an animal shelter. Itraconazole is the commonly used systemic antifungal drug, but it is expensive in some countries and, at times, difficult to obtain. Terbinafine is a fungicidal allylamine with documented in vitro and in vivo efficacy against Microsporum canis in pet cats and in cats with experimental infections. To describe the use of oral terbinafine for the treatment of M. canis dermatophytosis in shelter cats. The response to treatment of 85 shelter cats with naturally occurring M. canis dermatophytosis was monitored by examination, weekly toothbrush fungal cultures and the number of colony-forming units on fungal culture plates. Cats were treated with either 14 (n = 21) or 21 days (n = 64) of terbinafine per os (p.o.) along with concurrent twice weekly lime sulphur rinses and daily environmental disinfection. Cats treated with 14 days of terbinafine p.o. showed an initial response to therapy but by week 6 had relapsed and required rescue therapy with a course of itraconazole (10 mg/kg p.o.) to obtain a cure. Cats treated with 21 days of terbinafine p.o. showed a response to treatment similar to published reports using itraconazole p.o. for 21 days. The mean and median number of days to mycological cure was 22.70 (range 13-39). Terbinafine was well tolerated. None of the cats developed oral lesions postgrooming of lime sulphur rinses. Where itraconazole is not available, substitution with terbinafine in established protocols may allow shelters to treat cats that otherwise would go untreated. © 2013 ESVD and ACVD.

  7. Preston and Park-Sanders protocols adapted for semi-quantitative isolation of thermotolerant Campylobacter from chicken rinse

    DEFF Research Database (Denmark)

    Josefsen, Mathilde Hartmann; Lübeck, Peter Stephensen; Aalbaek, B.

    2003-01-01

    Human campylobacteriosis has become the major cause of foodborne gastrointestinal diseases in several European countries. In order to implement effective control measures in the primary production, and as a tool in risk assessment studies, it is necessary to have sensitive and quantitative...... detection methods. Thus, semi-quantitative detection of thermophilic Campylobacter spp. in 20 naturally contaminated chicken rinse samples was carried out using the two most common standard protocols: Preston and Park-Sanders, as proposed by Nordic Committee on Food Analysis (NMKL) and International...... Standard Organization (ISO), respectively. For both protocols, the chicken rinse samples were prepared in 500 ml buffered peptone water, as recommended in the ISO protocol no. 6887-2. The results indicated that the Preston protocol was superior to the Park-Sanders protocol in supporting growth...

  8. Influence of flooring type during transport and holding on bacteria recovery from broiler carcass rinses before and after defeathering.

    Science.gov (United States)

    Buhr, R J; Cason, J A; Dickens, J A; Hinton, A; Ingram, K D

    2000-03-01

    Four trials were conducted to determine whether conventional solid or elevated wire mesh flooring, during transport and holding of broilers prior to slaughter, influenced the number of bacteria recovered from feathered and defeathered carcasses. After 4 h off feed, 7-wk-old broilers were placed at commercial density into a modified commercial transport dump-coop on either fiberglass sheeting or 2.54x2.54 cm wire mesh flooring that allowed feces to fall through. Broilers were transported for 1 h and then held for 13 h under a covered shed before processing. Broilers were killed by electrocution, and the vents were plugged to prevent escape of feces. External carcass rinses were obtained twice (from the same carcass) from eight broilers per flooring treatment per trial, before scalding and defeathering and again after defeathering and removal of the head and feet. Greater numbers of total aerobes, coliforms, and Escherichia coli were recovered from feathered carcasses than from defeathered carcasses. Campylobacter count was also less for defeathered than feathered carcasses from the solid flooring treatment but did not significantly decrease following defeathering of carcasses from the wire flooring. The incidence of Campylobacter-positive carcasses was reduced following defeathering for both flooring treatments, but the percentage of Salmonellae-positive carcasses remained constant. Coliform (log10 6.20 vs. 5.63 cfu/mL of rinse) and E. coli (log10 5.93 vs. 5.36) counts in the feathered rinses were significantly higher for the solid flooring compared with wire flooring, respectively. After defeathering, the number of coliforms (log10 3.12) and E. coli (log10 2.91) recovered did not differ between flooring treatments. Aerobic plate count (log10 7.06 and 4.02), Campylobacter count (log10 2.49 and 1.80), and the incidence of Campylobacter-positive (44 and 11%) and Salmonellae-positive (52 and 50%) carcasses for feathered and defeathered rinses, respectively, did not

  9. Real-time ArcGIS and heterotrophic plate count based chloramine disinfectant control in water distribution system.

    Science.gov (United States)

    Bai, Xiaohui; Zhi, Xinghua; Zhu, Huifeng; Meng, Mingqun; Zhang, Mingde

    2015-01-01

    This study investigates the effect of chloramine residual on bacteria growth and regrowth and the relationship between heterotrophic plate counts (HPCs) and the concentration of chloramine residual in the Shanghai drinking water distribution system (DWDS). In this study, models to control HPCs in the water distribution system and consumer taps are also developed. Real-time ArcGIS was applied to show the distribution and changed results of the chloramine residual concentration in the pipe system by using these models. Residual regression analysis was used to get a reasonable range of the threshold values that allows the chloramine residual to efficiently inhibit bacteria growth in the Shanghai DWDS; the threshold values should be between 0.45 and 0.5 mg/L in pipe water and 0.2 and 0.25 mg/L in tap water. The low residual chloramine value (0.05 mg/L) of the Chinese drinking water quality standard may pose a potential health risk for microorganisms that should be improved. Disinfection by-products (DBPs) were detected, but no health risk was identified.

  10. Comparison of neck skin excision and whole carcass rinse sampling methods for determining Salmonella prevalence and E. coli counts on broiler carcasses before and after immersion chilling

    Science.gov (United States)

    A regulatory agency (FSIS) in the U.S. rinses whole broiler carcasses with 400 ml of 1% buffered peptone water (BPW) for Salmonella detection, while the European Union (EU) samples a 25g composited neck skin from three carcasses. The purpose of the study was to evaluate the FSIS and EU procedures fo...

  11. Electrochemical decomposition of fluorinated wetting agents in plating industry waste water.

    Science.gov (United States)

    Fath, Andreas; Sacher, Frank; McCaskie, John E

    2016-01-01

    Electrochemical decomposition of fluorinated surfactants (PFAS, perfluorinated alkyl substances) used in the plating industry was analyzed and the decomposition process parameters optimized at the laboratory scale and production scale of a 500-liter reactor using lead electrodes. The method and system was successfully demonstrated under production conditions to treat PFAS) with up to 99% efficiency in the concentration range of 1,000-20,000 μg/l (1 ppm-20 ppm). The treatment also reduced hexavalent chromium (Cr(6+)) ions to trivalent chromium (Cr(3+)) ions in the wastewater. If the PFAS-containing wastewater is mixed with other wastewater streams, specifically from nickel plating drag out solution or when pH values >5, the treatment process is ineffective. For the short chain PFAS, (perfluorobutylsulfonate) the process was less efficient than C6-C8 PFAS. The process is automated and has safety procedures and controls to prevent hazards. The PFAS were decomposed to hydrogen fluoride (HF) under the strong acid electrochemical operating conditions. Analytical tests showed no evidence of organic waste products remaining from the process. Conventional alternative PFAS removal systems were tested on the waste streams and compared with each other and with the-E-destruct (electrochemical oxidation) process. For example, ion exchange resin (IX resin) treatment of wastewater to complex and remove PFAS was found to be seven times more efficient when compared to the conventional activated carbon absorption (C-treat) process. However, the E-destruct process is higher in capacity, exhibits longer service life and lower operating costs than either IX or C-treat methods for elimination of PFAS from these electroplating waste streams.

  12. Residual stress improvement in multi-layer welded plates using water-shower cooling during welding process

    International Nuclear Information System (INIS)

    Yanagida, Nobuyoshi; Koide, Hiroo

    2006-01-01

    To reduce tensile residual stress in a welded region, we developed a new welding method that applies a water-shower behind the welding torch. When this method is applied to welding of austenitic stainless steel plates, cooling conditions mainly determine how much the residual stress can be reduced. To determine the conditions, we first used FEM to evaluate the effects of interpass temperature on the residual stress. And we found effective conditions for reducing tensile residual stress. To verify the validity of the conditions, specimens welded with or without water shower cooling were manufactured. Residual stresses of the specimens were experimentally measured. It was found that tensile residual stresses were generated on the surface of the welds and those were reduced in the case that the water-shower was applied. These measurement results agree well with the FEM analyses. It can therefore be concluded that the water-shower cooling during welding is appropriate for reducing tensile residual stress in austenitic stainless steel welding. (author)

  13. A novel wound rinsing solution based on nano colloidal silver

    Directory of Open Access Journals (Sweden)

    Soheila Kordestani

    2014-10-01

    Full Text Available Objective(s: The present study aimed to investigate the antiseptic properties of a colloidal nano silver wound rinsing solution to inhibit a wide range of pathogens including bacteria, viruses and fungus present in chronic and acute wounds. Materials and Methods:The wound rinsing solution named SilvoSept® was prepared using colloidal nano silver suspension. Physicochemical properties, effectiveness against microorganism including  Staphylocoocous aureus ATCC 6538P, Pseudomonas aeruginosa ATCC 9027, Escherichia coli ATCC 8739 ,Candida albicans ATCC 10231, Aspergillus niger ATCC 16404, MRSA , Mycobacterium spp. , HSV-1 and H1N1, and biocompatibility tests were carried out according to relevant standards . Results: X-ray diffraction (XRD scan was performed on the sample and verify single phase of silver particles in the compound. The size of the silver particles in the solution, measured by dynamic light scattering (DLS techniqu, ranged 80-90 nm. Transmission electron microscopy (TEM revealed spherical shape with smooth surface of the silver nanoparticles. SilvoSept® reduced 5 log from the initial count of 107 CFU/mL of Staphylocoocous aureus ATCC 6538P, Pseudomonas aeruginosa ATCC 9027, Escherichia coli ATCC 8739, Candida albicans ATCC 10231, Aspergillus niger ATCC 16404, MRSA, Mycobacterium spp. Further assessments of SilvoSept solution exhibited a significant inhibition on the replication of HSV-1 and H1N1. The biocompatibility studies showed that the solution was non-allergic, non-irritant and noncytotoxic. Conclusion: Findings of the present study showed that SilvoSept® wound rinsing solution containing nano silver particles is an effective antiseptic solution against a wide spectrum of microorganism. This compound can be a suitable candidate for wound irrigation.   

  14. Water harvesting for young trees using Peltier plates powered by photovoltaic solar energy

    OpenAIRE

    Muñoz-García, Miguel Angel; Moreda Cantero, Guillermo P.; Raga Arroyo, Manuela Pilar; Marín González, Omar

    2012-01-01

    Young trees transplanted from nursery into open field require a minimum amount of soil moisture to successfully root in their new location, especially in dry-climate areas. One possibility is to obtain the required water from air moisture. This can be achieved by reducing the temperature of a surface below the air dew point temperature, inducing water vapor condensation on the surface. The temperature of a surface can be reduced by applying the thermoelectric effect, with Peltier modules powe...

  15. Methylisothiazolinone in rinse-off products causes allergic contact dermatitis

    DEFF Research Database (Denmark)

    Yazar, K; Lundov, Michael Dyrgaard; Faurschou, A

    2015-01-01

    the potential to cause allergic contact dermatitis. METHODS: Nineteen MI-allergic subjects and 19 controls without MI allergy applied two liquid hand soaps five times per day on areas of 5 × 10 cm(2) on the ventral side of their forearms. One soap contained 100 ppm MI, the maximum allowed concentration......BACKGROUND: In recent years, the prevalence of contact allergy to the preservative methylisothiazolinone (MI) has increased dramatically. Cosmetic products are one of the major sources of exposure. OBJECTIVES: To examine whether allowed concentrations of MI in cosmetic rinse-off products have...

  16. A randomized, double‑blind clinical study to assess the antiplaque and antigingivitis efficacy of Aloe vera mouth rinse

    Directory of Open Access Journals (Sweden)

    Bathini Chandrahas

    2012-01-01

    Full Text Available Aims: To evaluate the efficacy of Aloe Vera mouth rinse on experimental plaque accumulation and gingivitis. Materials and Methods: In this randomized, controlled, and double-blind study, a total of 148 systemically healthy subjects were screened in the age group of 18-25 years. Finally, 120 subjects were requested to abstain from oral hygiene (tooth brushing for 14 days and used a specially fabricated plaque guard. Following cessation of tooth brushing in the specified area, the subjects were randomly divided into Group A (test group who received 100% Aloe vera, Group B (negative control group who received placebo (distilled water, and Group C (positive control group who received 0.2% chlorhexidine. The rinse regimen began on the 15 th day and continued for 7 days. Plaque accumulation was assessed by Plaque Index (PI and gingivitis was assessed by Modified Gingival Index (MGI and Bleeding Index (BI at baseline (0, 7 th , 14 th , and 22 nd days. Results: There was statistically significant decrease in PI, MGI, and BI scores after the rinse regimen began in both Group A (test group and Group C (chlorhexidine compared with Group B. Mouth wash containing Aloe vera showed significant reduction of plaque and gingivitis but when compared with chlorhexidine the effect was less significant. Conclusion: Aloe vera mouthwash can be an effective antiplaque agent and with appropriate refinements in taste and shelf life can be an affordable herbal substitute for chlorhexidine.

  17. An experimental investigation of the post-CHF enhancement factor for a prototypical ITER divertor plate with water coolant

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, T.D. [Rensselaer Polytechnic Institute, Troy, NY (United States); Watson, R.D.; McDonald, J.M. [Sandia National Lab., Albuquerque, NM (United States)] [and others

    1995-09-01

    In an off-normal event, water-cooled copper divertor plates in the International Thermonuclear Experimental Reactor (ITER) may either experience heat loads beyond their design basis, or the normal heat loads may be accompanied by low coolant pressure and velocity. The purpose of this experiment was to illustrate that during one-sided heating, as in ITER, a copper divertor plate with the proper side wall thickness, at low system pressure and velocity can absorb without failing an incident heat flux, q{sub i}, that significantly exceed the value, q{sub i}{sup CHF}, which is associated with local CHF at the wall of the coolant channel. The experiment was performed using a 30 kW electron beam test system for heating of a square cross-section divertor heat sink with a smooth circular channel of 7.63 mm diameter. The heated width, length, and wall thickness were 16, 40, and 3 mm, respectively. Stable surface temperatures were observed at incident heat fluxes greater than the local CHF point, presumably due to circumferential conduction around the thick tube walls when q{sub i}{sup CHF} was exceeded. The Post-CHF enhancement factor, {eta}, is defined as the ratio of the incident burnout heat flux, q{sub i}{sup BO}, to q{sub i}{sup CHF}. For this experiment with water at inlet conditions of 70{degrees}C, 1 m/s, and 1 MPa, q{sub i}{sup CHF} and q{sub i}{sup BO} were 600 and 1100 W/cm{sup 2}, respectively, which gave an {eta} of 1.8.

  18. Study on collapse behavior of a square plate subjected to water pressure; Suiatsu wo ukeru kukeiban no atsukai kyodo ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Yao, T; Fujikubo, M; Mizutani, K [Hiroshima University, Hiroshima (Japan). Faculty of Engineering

    1996-04-10

    Bottom plates of a hull are subjected to laterally distributing force due to in-plane compression force and water pressure in the ship`s length direction as a result of longitudinal bending in a hogging condition. Because buckling collapse of the hull bottom plates leads directly to longitudinal bending collapse of the hull bottom cross section, the hull bottom plates must have sufficient strength. The present study performs a static elastic large deflection analysis and an elasto-plastic large deflection analysis. It elucidates buckling collapse behavior of a square plate subjected to water pressure and in-plane compression load, and considers limits in application of conventional approximation analysis methods. In the case of a water pressure action, deflection components growing in excess of the buckling load do not necessarily correspond to buckling modes of the case where no water pressure is acting upon. Conventional approximation analysis methods may not be able often to pursue actual buckling phenomena. According the result of an analysis on hull bottom panels of an actual ship, the ultimate strength decreases when the water pressure is large. Compression force in the lateral direction as a result of water pressure acting on ship`s sides affected very little the ultimate strength. 3 refs., 7 figs.

  19. Simulation of the interaction of a solar domestic hot water tank system with a compact plate heat exchanger

    Energy Technology Data Exchange (ETDEWEB)

    Nizami, D.J.; Lightstone, M.F. [McMaster Univ., Hamilton, ON (Canada). Dept. of Mechanical Engineering; Harrison, S.; Cruickshank, C. [Queen' s Univ., Kingston, ON (Canada). Dept. of Mechanical and Materials Engineering

    2008-08-15

    An external natural convection heat exchanger (NCHE) was used as an alternative to forced convection for transferring energy from solar collector loops to a hot water storage tank. A computational fluid dynamics (CFD) program was used to predict interactions between the natural convection-driven side-arm heat exchanger and a hot water storage tank. A solar domestic hot water tank with a vertical compact plate natural convection heat exchanger was modelled. In addition, the heat exchanger was modelled as a section of pipe with high flow resistance and a volumetric energy source. Transient analyses were conducted and the CFD model was then compared with data obtained from laboratory experiments. Simulations were conducted on the fluid domain in order to investigate the influence of the flow on the thermal stratification in the tank, the heat transfer inside the tank, and the natural convection in the tank loop. Buoyancy for an incompressible fluid with constant fluid properties was modelled using a Boussinesq approximation. Temperature distributions were measured as a function of time. Results of the study indicated that assuming a constant thermal expansion coefficient in evaluation buoyancy forces for a wide range of operating temperatures did not result in accurate predictions. Future studies will model natural convection with a full buoyancy model. 11 refs., 2 tabs., 5 figs.

  20. Thermal analysis and performance optimization of a solar water heater flat plate collector: Application to Tetouan (Morocco)

    International Nuclear Information System (INIS)

    Dagdougui, Hanane; Ouammi, Ahmed; Robba, Michela; Sacile, Roberto

    2011-01-01

    The development of sustainable energy services like the supply of heating water may face a trade-off with a comfortable quality of life, especially in the winter season where suitable strategies to deliver an effective service are required. This paper investigates the heat transfer process as well as the thermal behavior of a flat plate collector evaluating different cover configurations. This investigation is performed according to a two-folded approach. Firstly, a complete model is formulated and implemented taking into account various modes of heat transfer in the collector. The goal is to investigate the impact of the number and types of covers on the top heat loss and the related thermal performance in order to support decision makers about the most cost-effective design. The proposed model can also be used to investigate the effect of the different parameters which may affect the performance of the collector. Secondly, a two objective constrained optimization model has been formulated and implemented to evaluate the optimality of different design approaches. The goal is to support decision makers in the definition of the optimal water flow and of the optimal collector flat area in order to give a good compromise between the collector efficiency and the output water temperature. The overall methodology has been tested on environmental data (temperature and irradiation) which are characteristic of Tetouan (Morocco). (author)

  1. Effect of xylitol, sodium fluoride and triclosan containing mouth rinse on Streptococcus mutans

    Directory of Open Access Journals (Sweden)

    Priya Subramaniam

    2011-01-01

    Full Text Available Introduction : Prevention of dental caries is one of the main strategies in contemporary pediatric dental practice. Mouth rinses are widely used as an adjunct to maintain oral hygiene. It is important for these products to be effective and safe for regular use in children. Objective : The aim of the study was to investigate the efficacy of a newly introduced xylitol, sodium fluoride and triclosan containing mouth rinse in reducing levels of plaque Streptococcus mutans and to compare it with that of a 0.12% chlorhexidine mouth rinse. Materials and Methods : Thirty children were randomly divided into two groups of 15 children each. Group I (study group was given a mouth rinse containing xylitol (5%, sodium fluoride (0.05% and triclosan (0.03% and Group II (control group was given a chlorhexidine (0.12% mouth rinse. Both mouth rinses were alcohol free. Mouth rinsing was carried out twice daily, half an hour after breakfast and half an hour following dinner, for a period of 21 days under the supervision of the investigator. Results: In both groups, there was a significant reduction in the mean S. mutans count at the end of 21 days (P < 0.001. No significant difference was observed between the two mouth rinses. Conclusion: The use of a low fluoride-xylitol based mouth rinse appears to be a suitable choice for regular use in children.

  2. Influence of oral rinsing on the exposure of salivary glands during radioiodine therapy

    International Nuclear Information System (INIS)

    Luetzen, U.; Silvia, P.; Zhao, Y.; Marx, M.; Winkler, C.; Zuhayra, M.

    2015-01-01

    Full text of publication follows. Aim: the salivary glands (SG) constitute a risk organ during a radioiodine therapy of thyroid. A possible side effect is xerostomia. This study investigates whether repeated rinsing of the mouth with water during radioiodine therapy significantly extracts I-131 from the circuit between saliva and the gastrointestinal tract, and thus whether radiation exposure of the patient's SG is reduced. Methods: the control group consisted of 45 patients, ages 32 to 81 years, (mean 62 years, 8 male, 37 female), and received radioiodine therapy without rinsing their mouths. An intervention group of 42 patients, ages 36 to 88 years, (mean 61 years, 8 male, 34 female), with a benign or malignant thyroid disease, were asked 15-17 hours after capsule administration to rinse their mouths hourly with water for the next two days. The intervention group (n = 42) was divided into three groups. A low-risk group (n = 22) received between 0.4 and 1.0 GBq I-131 (mean 0.746), a medium risk group (n = 15) between 1.2 and 2.0 GBq (mean 1.783), and the high-risk group (n = 5) between 3.0 and 6.0 GBq (mean 3.600) respectively. To assess the function of the SG, scintigrams were performed prior to and 3 months after the radioiodine therapy. The estimation of the activity in the gastrointestinal tract was performed using whole-body scintigraphy on the day of release. Both, the SG and the whole body (WB) scintigraphies were evaluated using the region-of-interest technique. Furthermore, the activity of the collected saliva was quantified using a calibrated well-type detector. Results: the mean values of the activity extracted into the water-saliva mixture were 0.72% ± 0.3% and 0.14% ± 0.05% of the applied dose on the first and second day after capsule administration respectively. The analysis of the SG scintigrams of the low and medium risk groups showed no significant decrease in salivary gland function. Only in the high-risk group a significant loss of

  3. A plate reader-based method for cell water permeability measurement

    DEFF Research Database (Denmark)

    Fenton, Robert A.; Moeller, H B; Nielsen, S

    2010-01-01

    Cell volume and water permeability measurements in cultured mammalian cells are typically conducted under a light microscope. Many of the employed approaches are time consuming and not applicable to a study of confluent epithelial cell monolayers. We present here an adaptation of a calcein......: AQP2-S256D > AQP2 wild-type > AQP2-S256A. We propose that the method can be applied to study AQP function and more generally to study cell volume changes in adherent cell lines. Furthermore, it should be adaptable for AQP inhibitor screening in chemical compound libraries....

  4. Heat transfer performance of silver/water nanofluid in a solar flat-plate collector

    OpenAIRE

    Lazarus, Godson; Roy, Siddharth; Kunhappan, Deepak; Cephas, Enoch; Wongwises, Somchai

    2015-01-01

    An experimental study is carried out to investigate the heat transfer characteristics of silver/water nanofluid in a solar flatplate collector. The solar radiation heat flux varies between 800 W/m2and 1000W/m2, and the particle concentration varies between 0.01%, 0.03%, and 0.04%. The fluid Reynolds number varies from 5000 to 25000. The influence of radiation heat flux, mass flow rate of nanofluid, inlet temperature into the solar collector, and volume concentration of the particle on the con...

  5. Mouth rinsing with a carbohydrate solution attenuates exercise-induced decline in executive function.

    Science.gov (United States)

    Konishi, Kana; Kimura, Tetsuya; Yuhaku, Atsushi; Kurihara, Toshiyuki; Fujimoto, Masahiro; Hamaoka, Takafumi; Sanada, Kiyoshi

    2017-01-01

    A decline in executive function could have a negative influence on the control of actions in dynamic situations, such as sports activities. Mouth rinsing with a carbohydrate solution could serve as an effective treatment for preserving the executive function in exercise. The purpose of this study was to examine the effects of mouth rinsing with a carbohydrate solution on executive function after sustained moderately high-intensity exercise. Eight young healthy participants completed 65 min of running at 75% V̇O 2 max with two mouth-rinsing conditions: with a carbohydrate solution (CHO) or with water (CON). Executive function was assessed before and after exercise by using the incongruent task of the Stroop Color and Word Test. The levels of blood glucose; and plasma adrenocorticotropic hormone (ACTH), epinephrine, and norepinephrine (NE) were evaluated. A two-way repeated-measures ANOVA, with condition (CHO and CON) and time (pre-exercise and post-exercise) as factors, was used to examine the main and interaction effects on the outcome measures. The reaction time in the incongruent condition of the Stroop test significantly increased after exercise in CON (pre-exercise 529 ± 45 ms vs. post-exercise 547 ± 60 ms, P  = 0.029) but not in CHO (pre-exercise 531 ± 54 ms vs. post-exercise 522 ± 80 ms), which resulted in a significant interaction (condition × time) on the reaction time ( P  = 0.028). The increased reaction time in CON indicates a decline in the executive function, which was attenuated in CHO. Increases in plasma epinephrine and NE levels demonstrated a trend toward attenuation accompanying CHO ( P  exercise, and that such attenuation seems to be unrelated to carbohydrate metabolic pathway but rather attributed, in part, to the inhibition of the excessive release of stress hormones.

  6. Development of a brazing process for the production of water- cooled bipolar plates made of chromium-coated metal foils for PEM fuel cells

    International Nuclear Information System (INIS)

    Mueller, M; Hoehlich, D; Scharf, I; Lampke, T; Hollaender, U; Maier, H J

    2016-01-01

    Beside lithium batteries, PEM fuel cells are the most promising strategy as a power source to achieve the targets for introducing and increasing the usage of electric vehicles. Due to limited space and weight problems, water cooled, metallic bipolar plates in a fuel cell metal stack are preferred in motor vehicles. These plates are stamped metal sheets with a complex structure, interconnected media-tight. To meet the multiple tasks and requirements in use, complex and expensive combinations of materials are currently in use (carbon fiber composites, graphite, gold-plated nickel, stainless and acid resistant steel). The production of such plates is expensive as it is connected with considerable effort or the usage of precious metals. As an alternative, metalloid nitrides (CrN, VN, W 2 N, etc.) show a high chemical resistance, hardness and a good conductivity. So this material category meets the basic requirements of a top layer. However, the standard methods for their production (PVD, CVD) are expensive and have a slow deposition rate and a lower layer thicknesses. Because of these limitations, a full functionality over the life cycle of a bipolar plate is not guaranteed. The contribution shows the development and quantification of an alternative production process for bipolar plates. The expectation is to get significant advantages from the combination of chromium electrodeposition and thermochemical treatment to form chromium nitrides. Both processes are well researched and suitable for series production. The thermochemical treatment of the chromium layer also enables a process-integrated brazing. (paper)

  7. The influence of walls and upper tie plate slots on the flooding mechanism in fuel elements with and without heat transfer between steam and water

    International Nuclear Information System (INIS)

    Spatz, R.; Mewes, D.

    1989-01-01

    The counter-current flow of steam and water was experimentally investigated for the upper part of a PWR fuel element. The actual geometrical shape of the nuclear equipment was simulated by various types of plates, in which bore holes and slots were arranged in different positions. The experiments were performed with and without an installed, unheated rod bundle below the plates. The water was injected at saturated and subcooled temperatures in order to observe the effects of heat transfer on counter-current flow. With increasing steam velocity the flooding occurs initially in the tie-plate area. If the rod bundle is installed in the flow duct, a part of the downwards flowing water is transported upwards from the region of the upper grid spacer to the plate. Heat transfer between the phases can cause in the counter-current flow region an instable transition from downward to near complete upward directed liquid flow. In comparison to experiments with saturated water injection, flooding occurs at larger steam velocities. Different flooding correlations, which are known from the literature, were compared with the experimental data to appraise their applicability to counter-current flow in the core of PWRs. (orig.)

  8. Condensation heat transfer correlation for water-ethanol vapor mixture flowing through a plate heat exchanger

    Science.gov (United States)

    Zhou, Weiqing; Hu, Shenhua; Ma, Xiangrong; Zhou, Feng

    2018-04-01

    Condensation heat transfer coefficient (HTC) as a function of outlet vapor quality was investigated using water-ethanol vapor mixture of different ethanol vapor concentrations (0%, 1%, 2%, 5%, 10%, 20%) under three different system pressures (31 kPa, 47 kPa, 83 kPa). A heat transfer coefficient was developed by applying multiple linear regression method to experimental data, taking into account the dimensionless numbers which represents the Marangoni condensation effects, such as Re, Pr, Ja, Ma and Sh. The developed correlation can predict the condensation performance within a deviation range from -22% to 32%. Taking PHE's characteristic into consideration and bringing in Ma number and Sh number, a new correlation was developed, which showed a much more accurate prediction, within a deviation from -3.2% to 7.9%.

  9. In vitro antifungal effect of mouth rinses containing chlorhexidine and thymol

    Directory of Open Access Journals (Sweden)

    Ashish Shrestha

    2011-03-01

    Conclusions: Antimicrobial agents used in the study had good in vitro activity against the two Candida species. Mouth rinses containing chlorhexidine showed superior antifungal and fungicidal activities compared to the thymol-containing mouth rinse. Both antimicrobial agents may be suggested for use as topical antifungal agents.

  10. Is carbohydrate mouth rinsing a novel approach to maintain exercise performance during Ramadan fasting?

    Directory of Open Access Journals (Sweden)

    Ahmad Munir Che Muhamed

    2014-12-01

    Full Text Available About a decade ago, carbohydrate mouth rinsing was shown to enhance endurance exercise performance. This improvement was more pronounced in a fasted compared to a fed state, suggesting that the ergogenic effect of carbohydrate mouth rinse is dependent on endogenous carbohydrate storage. Hence, indirectly highlights the potential use of carbohydrate mouth rinse as a potential strategy to mitigate the adverse effects of exercise during Ramadan fasting. To date, only one study has been carried out to explore the potential benefit of carbohydrate mouth rinse on exercise performance during Ramadan fasting. This single observation showed that a 10-km time trial performance was enhanced when performing mouth rinsing with either a carbohydrate or a placebo solution as compared with not performing mouth rinsing. While one study had acknowledged that the practice of mouth rinsing do have a positive effect on exercise performance during Ramadan fasting, future studies is warranted in order to have a better understanding on the underlying mechanisms associated with carbohydrate mouth rinsing during Ramadan fasting.

  11. Caffeine and 3-km cycling performance: Effects of mouth rinsing, genotype, and time of day.

    Science.gov (United States)

    Pataky, M W; Womack, C J; Saunders, M J; Goffe, J L; D'Lugos, A C; El-Sohemy, A; Luden, N D

    2016-06-01

    We assessed the efficacy of caffeine mouth rinsing on 3-km cycling performance and determined whether caffeine mouth rinsing affects performance gains influenced by the CYP1A2 polymorphism. Thirty-eight recreational cyclists completed four simulated 3-km time trials (TT). Subjects ingested either 6 mg/kg BW of caffeine or placebo 1 h prior to each TT. Additionally, 25 mL of 1.14% caffeine or placebo solution were mouth rinsed before each TT. The treatments were Placebo, caffeine Ingestion, caffeine Rinse and Ingestion+Rinse. Subjects were genotyped and classified as AA homozygotes or AC heterozygotes for the rs762551 polymorphism of the CYP1A2 gene involved in caffeine metabolism. Magnitude-based inferences were used to evaluate treatment differences in mean power output based on a predetermined meaningful treatment effect of 1.0%. AC heterozygotes (4.1%) and AA homozygotes (3.4%) benefited from Ingestion+Rinse, but only AC performed better with Ingestion (6.0%). Additionally, Rinse and Ingestion+Rinse elicited better performance relative to Placebo among subjects that performed prior to 10:00 h (Early) compared with after 10:00 h (Late). The present study provides additional evidence of genotype and time of day factors that affect the ergogenic value of caffeine intake that may allow for more personalized caffeine intake strategies to maximize performance. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Carbohydrate mouth rinse: does it improve endurance exercise performance?

    Directory of Open Access Journals (Sweden)

    Painelli Vitor

    2010-08-01

    Full Text Available Abstract It is well known that carbohydrate (CHO supplementation can improve performance in endurance exercises through several mechanisms such as maintenance of glycemia and sparing endogenous glycogen as well as the possibility of a central nervous-system action. Some studies have emerged in recent years in order to test the hypothesis of ergogenic action via central nervous system. Recent studies have demonstrated that CHO mouth rinse can lead to improved performance of cyclists, and this may be associated with the activation of brain areas linked to motivation and reward. These findings have already been replicated in other endurance modalities, such as running. This alternative seems to be an attractive nutritional tool to improve endurance exercise performance.

  13. Cold plate

    Energy Technology Data Exchange (ETDEWEB)

    Marroquin, Christopher M.; O' Connell, Kevin M.; Schultz, Mark D.; Tian, Shurong

    2018-02-13

    A cold plate, an electronic assembly including a cold plate, and a method for forming a cold plate are provided. The cold plate includes an interface plate and an opposing plate that form a plenum. The cold plate includes a plurality of active areas arranged for alignment over respective heat generating portions of an electronic assembly, and non-active areas between the active areas. A cooling fluid flows through the plenum. The plenum, at the non-active areas, has a reduced width and/or reduced height relative to the plenum at the active areas. The reduced width and/or height of the plenum, and exterior dimensions of cold plate, at the non-active areas allow the non-active areas to flex to accommodate surface variations of the electronics assembly. The reduced width and/or height non-active areas can be specifically shaped to fit between physical features of the electronics assembly.

  14. Performance augmentation in flat plate solar collector using MgO/water nanofluid

    International Nuclear Information System (INIS)

    Verma, Sujit Kumar; Tiwari, Arun Kumar; Chauhan, Durg Singh

    2016-01-01

    Highlights: • Use of nanofluid improves the performance of solar collector. • Thermo-physical properties of the nanofluid have been discussed. • Optimum particle concentrations are found to exist. • Bejan number reaches closer to unity. - Abstract: In present work, testing of solar collector has been performed for MgO/water working fluid having particle size ∼40 nm and particle volume concentration at 0.25, 0.5, 0.75, 1.0, 1.25 and 1.5% at 0.5, 1.0, 1.5, 2.0, 2.5 lpm respectively. Performance analysis of solar collector is based on first law of energy balance and qualitative nature of energy flow based on second law analysis. Parameters of performance analysis are chosen in order to examine both quantitative and qualitative characteristics of system performance. These parameters are thermal efficiency, energetic efficiency, pumping power, entropy generation; Bejan number and reduction in surface area. Experimental observation establishes thermal efficiency enhancement 9.34% for 0.75% particle volume concentration at flow rate 1.5 lpm. Exergetic efficiency enhancement observed 32.23% for same concentration and flow rate. Bejan number also reaches closer to unity (0.97) which throws light on systems qualitative response in terms of decline in entropy generation contribution due to internal irreversibilities and frictional heat loss. Entropy generation is 0.0611 W/K for 0.75% particle concentration compare to 0.1394 W/K for same flow rate and 0.071 W/K for 1.5% particle volume concentration. In this endeavor some penalty in form of rise in pumping power loss also incurred. 6.84% enhancement in pumping power loss observed for optimum flow rate and particle volume concentration which has not as much pronounced effect as enhancement in thermal efficiency and exergetic efficiency.

  15. Plating laboratory

    International Nuclear Information System (INIS)

    Seamster, A.G.; Weitkamp, W.G.

    1984-01-01

    The lead plating of the prototype resonator has been conducted entirely in the plating laboratory at SUNY Stony Brook. Because of the considerable cost and inconvenience in transporting personnel and materials to and from Stony Brook, it is clearly impractical to plate all the resonators there. Furthermore, the high-beta resonator cannot be accommodated at Stony Brook without modifying the set up there. Consequently the authors are constructing a plating lab in-house

  16. SIMULATION OF SOLAR LITHIUM BROMIDE–WATER ABSORPTION COOLING SYSTEM WITH DOUBLE GLAZED FLAT PLATE COLLECTOR FOR ADRAR

    Directory of Open Access Journals (Sweden)

    ML CHOUGUI

    2014-12-01

    Full Text Available Adrar is a city in the Sahara desert, in southern Algeria known for its hot and dry climate, where a huge amount of energy is used for air conditioning. The aim of this research is to simulate a single effect lithium bromide–water absorption chiller coupled to a double-glazed flat plate collector to supply the cooling loads for a house of 200m2 in Adrar. The thermal energy is stored in an insulated thermal storage tank. The system was designed to cover a cooling load of 10.39KW for design day of July. Thermodynamic model was established to simulate the absorption cycle. The results have shown that the collector mass flow rate has a negligible effect on the minimum required collector area, but it has a significant effect on the optimum capacity of the storage tank. The minimum required collector area was about 65.3 m2, which could supply the cooling loads for the sunshine hours of the design day for July. The operation of the system has also been considered after sunset by saving solar energy.

  17. Recovery of salmonella serovar enteritidis from inoculated broiler hatching eggs using shell rinse and shell crush sampling methods

    Science.gov (United States)

    This study compared the recovery of Salmonella from hatching eggs using three sampling methods (eggshell rinsing, eggshell crush following a previous rinse, and eggshell crush without previous rinse). Eggshells were drop-inoculated with approximately 10, 100, or 1,000 cfu/eggshell of S. Enteritidis...

  18. Determination of absorbed dose to water from a miniature kilovoltage x-ray source using a parallel-plate ionization chamber

    Science.gov (United States)

    Watson, Peter G. F.; Popovic, Marija; Seuntjens, Jan

    2018-01-01

    Electronic brachytherapy sources are widely accepted as alternatives to radionuclide-based systems. Yet, formal dosimetry standards for these devices to independently complement the dose protocol provided by the manufacturer are lacking. This article presents a formalism for calculating and independently verifying the absorbed dose to water from a kV x-ray source (The INTRABEAM System) measured in a water phantom with an ionization chamber calibrated in terms of air-kerma. This formalism uses a Monte Carlo (MC) calculated chamber conversion factor, CQ , to convert air-kerma in a reference beam to absorbed dose to water in the measurement beam. In this work CQ was determined for a PTW 34013 parallel-plate ionization chamber. Our results show that CQ was sensitive to the chamber plate separation tolerance, with differences of up to 15%. CQ was also found to have a depth dependence which varied with chamber plate separation (0 to 10% variation for the smallest and largest cavity height, over 3 to 30 mm depth). However for all chamber dimensions investigated, CQ was found to be significantly larger than the manufacturer reported value, suggesting that the manufacturer recommended method of dose calculation could be underestimating the dose to water.

  19. A Soil-Plate Based Pipeline for Assessing Cereal Root Growth in Response to Polyethylene Glycol (PEG)-Induced Water Deficit Stress.

    Science.gov (United States)

    Nelson, Sven K; Oliver, Melvin J

    2017-01-01

    Drought is a serious problem that causes losses in crop-yield every year, but the mechanisms underlying how roots respond to water deficit are difficult to study under controlled conditions. Methods for assaying root elongation and architecture, especially for seedlings, are commonly achieved on artificial media, such as agar, moistened filter paper, or in hydroponic systems. However, it has been demonstrated that measuring root characteristics under such conditions does not accurately mimic what is observed when plants are grown in soil. Morphological changes in root behavior occur because of differences in solute diffusion, mechanical impedance, exposure to light (in some designs), and gas exchange of roots grown under these conditions. To address such deficiencies, we developed a quantitative method for assaying seedling root lengths and germination in soil using a plate-based approach with wheat as a model crop. We also further developed the method to include defined water deficits stress levels using the osmotic properties of polyethylene glycol (PEG). Seeds were sown into soil-filled vertical plates and grown in the dark. Root length measurements were collected using digital photography through the transparent lid under green lighting to avoid effects of white light exposure on growth. Photographs were analyzed using the cross-platform ImageJ plugin, SmartRoot, which can detect root edges and partially automate root detection for extraction of lengths. This allowed for quick measurements and straightforward and accurate assessments of non-linear roots. Other measurements, such as root width or angle, can also be collected by this method. An R function was developed to collect exported root length data, process and reformat the data, and output plots depicting root/shoot growth dynamics. For water deficit experiments, seedlings were transplanted side-by-side into well-watered plates and plates containing PEG solutions to simulate precise water deficits.

  20. Antiseptic mouth rinses: an update on comparative effectiveness, risks and recommendations.

    Science.gov (United States)

    Osso, Diane; Kanani, Nehal

    2013-02-01

    Antiseptic mouth rinses are widely recommended and marketed to improve oral health. This article summarizes current studies on the comparative effectiveness of selected antiseptic mouth rinses in controlling plaque and gingivitis, as well as risks associated with daily exposure, including salivary flow rate, oral cancer and wear of composite restorations. Electronic database searches were conducted using Google Scholar and PubMed to identify articles comparing the effectiveness of 4 commercially marketed antiseptic mouth rinses differing in active ingredients (0.12% chlorhexidine gluconate, essential oils (menthol, thymol and eucalyptol) and methyl salicylate, 0.7% cetylpyridinium chloride and 20% aloe vera gel) for controlling plaque and gingivitis. Criteria for inclusion included controlled clinical trials and systematic reviews appearing in English language publications evaluating the comparative effectiveness of the mouth rinses in controlling plaque and gingivitis, as well as risks associated with daily usage. The majority of studies have shown mouth rinses containing chlorhexidine gluconate or essential oils and methyl salicylate provide clinically significant anti-gingivitis and anti-plaque benefits. Cetylpyridinium chloride has been found to provide only limited clinical benefits compared to inactive control mouth rinse. Inadequate evidence is available to evaluate the clinical effectiveness of aloe vera gel. Chlorhexidine, essential oils and cetylpyridinium have been found to be safe. However, limited data are available on the effects of the mouth rinse on wear patterns of dental restorations. Studies reviewed reported no significant difference in salivary flow rate related to alcohol based mouth rinse. Research supports the effectiveness of antiseptic mouth rinses in reducing plaque and gingivitis as an adjunct to home care. Insufficient evidence is available to support the claim that oral antiseptics can reduce the risk of developing periodontitis or the

  1. Extrafibrillar collagen demineralization-based chelate-and-rinse technique bridges the gap between wet and dry dentin bonding.

    Science.gov (United States)

    Mai, Sui; Wei, Chin-Chuan; Gu, Li-Sha; Tian, Fu-Cong; Arola, Dwayne D; Chen, Ji-Hua; Jiao, Yang; Pashley, David H; Niu, Li-Na; Tay, Franklin R

    2017-07-15

    Limitations associated with wet-bonding led to the recent development of a selective demineralization strategy in which dentin was etched with a reduced concentration of phosphoric acid to create exclusive extrafibrillar demineralization of the collagen matrix. However, the use of acidic conditioners removes calcium via diffusion of very small hydronium ions into the intrafibrillar collagen water compartments. This defeats the purpose of limiting the conditioner to the extrafibrillar space to create a collagen matrix containing only intrafibrillar minerals to prevent collapse of the collagen matrix. The present work examined the use of polymeric chelators (the sodium salt of polyacrylic acid) of different molecular weights to selectively demineralize extrafibrillar dentin. These polymeric chelators exhibit different affinities for calcium ions (isothermal titration calorimetry), penetrated intrafibrillar dentin collagen to different extents based on their molecular sizes (modified size-exclusion chromatography), and preserve the dynamic mechanical properties of mineralized dentin more favorably compared with completely demineralized phosphoric acid-etched dentin (nanoscopical dynamic mechanical analysis). Scanning and transmission electron microscopy provided evidence for retention of intrafibrillar minerals in dentin surfaces conditioned with polymeric chelators. Microtensile bond strengths to wet-bonded and dry-bonded dentin conditioned with these polymeric chelators showed that the use of sodium salts of polyacrylic acid for chelating dentin prior to bonding did not result in significant decline in resin-dentin bond strength. Taken together, the findings led to the conclusion that a chelate-and-rinse conditioning technique based on extrafibrillar collagen demineralization bridges the gap between wet and dry dentin bonding. The chelate-and-rinse dental adhesive bonding concept differentiates from previous research in that it is based on the size

  2. Suppression of Plesiomonas shigelloides growth in the Direct Plating method for the enumeration of Escherichia coli in water

    NARCIS (Netherlands)

    Schets FM; List C; Kadar M; de Ruiter H; Medema GJ; MGB; Water Storage Corporation Brabantse Biesbosch; Werkendam; National Institute of Hygiene; Budapest; RIZA; Lelystad

    1998-01-01

    Plesiomonas shigelloides bleek vals positieve reacties te veroorzaken in de Escherichia coli Direct Plating (DP) methode. In het hier beschreven onderzoek is geprobeerd de groei van Plesiomonas te onderdrukken door toevoeging van het vibriostaticum O/129

  3. Critical heat flux analysis on change of plate temperature and cooling water flow rate for rectangular narrow gap with bilateral-heated cases

    International Nuclear Information System (INIS)

    M Hadi Kusuma; Mulya Juarsa; Anhar Riza Antariksawan

    2013-01-01

    Boiling heat transfer phenomena on rectangular narrow gap was related to the safety of nuclear reactors. Research done in order to study the safety of nuclear reactors in particular relating to boiling heat transfer and useful on the improvement of next-generation reactor designs. The research focused on calculation of the heat flux during the cooling process in rectangular narrow gap size 1.0 mm. with initial temperatures 200°C. 400°C, and 600°C, also the flow rates of cooling water 0,1 liters/second. 0,2 liters/second. and 0,3 liters/second. Experiments carried out by injecting water at a certain flow rate with the water temperature 85°C. Transient temperature measurement data recorded by the data acquisition system. Transient temperature measurement data is used to calculate the flux of heat gain is then used to obtain the heat transfer coefficient. This research aimed to obtain the correlation between critical heat flux and heat transfer coefficient to changes in temperatures and water flow rates for bilaterally-heated cases on rectangular narrow gap. The results obtained for a constant cooling water flow rate, critical heat flux will increase when hot plate temperature also increased. While on a constant hot plate temperature, coefficient heat transfer will increase when cooling water flow rate also increased. Thus it can be said that the cooling water flow rate and temperature of the hot plate has a significant effect on the critical heat flux and heat transfer coefficient resulted in quenching process of vertical rectangular narrow gap with double-heated cases. (author)

  4. Effective Reuse of Electroplating Rinse Wastewater by Combining PAC with H2O2/UV Process.

    Science.gov (United States)

    Yen, Hsing Yuan; Kang, Shyh-Fang; Lin, Chen Pei

    2015-04-01

    This study evaluated the performance of treating electroplating rinse wastewater by powder activated carbon (PAC) adsorption, H2O2/UV oxidation, and their combination to remove organic compounds and heavy metals. The results showed that neither the process of PAC adsorption nor H2O2/UV oxidation could reduce COD to 100 mg/L, as enforced by the Taiwan Environmental Protection Agency. On the other hand, the water sample treated by the combined approach of using PAC (5 g/L) pre-adsorption and H2O2/UV post-oxidation (UV of 64 W, H2O2 of 100 mg/L, oxidation time of 90 min), COD and DOC were reduced to 8.2 mg/L and 3.8 mg/L, respectively. Also, the combined approach reduced heavy metals to meet the effluent standards and to satisfy the in-house water reuse criteria for the electroplating factory. The reaction constant analysis indicated that the reaction proceeded much more rapidly for the combined process. Hence, it is a more efficient, economic and environmentally friendly process.

  5. Effect of plate shapes in orifice plate type flowmeters

    International Nuclear Information System (INIS)

    Moeller, S.V.

    1984-01-01

    The study of unusual plate shapes in orifice plate type flowmeters is presented, with a view to providing data for the substitution of the plate with one centered circular orifice in those applications where its use is not possible. For this purpose, six pairs of plates with different forms, with and without chamfered edges, were made and tested in a closed water loop. Results show that, generally, the use of chamfers improves the results and, in the case of perforated and slotlike orificed plates, the narrow-ness of the fluid passage tends to make unnecessary its use. (Author) [pt

  6. Experimental etch-and-rinse adhesive systems containing MMP-inhibitors: Physicochemical characterization and resin-dentin bonding stability.

    Science.gov (United States)

    da Silva, Eduardo Moreira; de Sá Rodrigues, Carolina Ullmann Fernandes; de Oliveira Matos, Marcos Paulo; de Carvalho, Thais Rodrigues; dos Santos, Glauco Botelho; Amaral, Cristiane Mariote

    2015-12-01

    To evaluate the degree of conversion (DC%), water sorption (WS), solubility (SO) and the resin-dentin bonding stability (μTBS) of experimental (EXP) etch-and-rinse adhesive systems containing MMP-inhibitors: Galardin-GAL, Batimastat-BAT, GM1489-GM1 and chlorhexidine diacetate-CHX. DC% was measured using FT-IR spectroscopy, while WS and SO were calculated based on ISO4049. Thirty-six human molars were wet ground until the occlusal dentin was exposed. The adhesive systems were applied and resin composite buildups were incrementally constructed. After 24 h immersion in distilled water at 37 °C, the specimens were cut into resin-dentin beams with a cross-sectional area of 1 mm(2). The μTBS was evaluated after 24 h, 6 months and 12 months of water storage at 37 °C. Adper Single Bond 2 (SB2) was used as a commercial control. The data were analyzed using ANOVA and Tukey's HSD test. SB2 presented the highest DC% (p0.05). SO was found to be not significant (p>0.05). All adhesive systems maintained μTBS stability after 6 months of water storage. Only BAT, GM1 and CHX maintained μTBs stability after 12 months of water storage. The experimental adhesive systems with GM1489 and chlorhexidine diacetate presented the best physicochemical properties and preserved resin-dentin bonding stability after 12 months of water storage. GM1489 could be suitable for inclusion as an MMP-inhibitor in etch-and-rinse adhesive systems to maintain resin-dentin bonding stability over time. Copyright © 2015. Published by Elsevier Ltd.

  7. The Influence of Serial Carbohydrate Mouth Rinsing on Power Output during a Cycle Sprint.

    Science.gov (United States)

    Phillips, Shaun M; Findlay, Scott; Kavaliauskas, Mykolas; Grant, Marie Clare

    2014-05-01

    The objective of the study was to investigate the influence of serial administration of a carbohydrate (CHO) mouth rinse on performance, metabolic and perceptual responses during a cycle sprint. Twelve physically active males (mean (± SD) age: 23.1 (3.0) years, height: 1.83 (0.07) m, body mass (BM): 86.3 (13.5) kg) completed the following mouth rinse trials in a randomized, counterbalanced, double-blind fashion; 1. 8 x 5 second rinses with a 25 ml CHO (6% w/v maltodextrin) solution, 2. 8 x 5 second rinses with a 25 ml placebo (PLA) solution. Following mouth rinse administration, participants completed a 30 second sprint on a cycle ergometer against a 0.075 g·kg(-1) BM resistance. Eight participants achieved a greater peak power output (PPO) in the CHO trial, resulting in a significantly greater PPO compared with PLA (13.51 ± 2.19 vs. 13.20 ± 2.14 W·kg(-1), p 0.05). No significant between-trials difference was reported for fatigue index, perceived exertion, arousal and nausea levels, or blood lactate and glucose concentrations. Serial administration of a CHO mouth rinse may significantly improve PPO during a cycle sprint. This improvement appears confined to the first 5 seconds of the sprint, and may come at a greater relative cost for the remainder of the sprint. Key pointsThe paper demonstrates that repeated administration of a carbohydrate mouth rinse can significantly improve peak power output during a single 30 second cycle sprint.The ergogenic effect of the carbohydrate mouth rinse may relate to the duration of exposure of the oral cavity to the mouth rinse, and associated greater stimulation of oral carbohydrate receptors.The significant increase in peak power output with the carbohydrate mouth rinse may come at a relative cost for the remainder of the sprint, evidenced by non-significantly lower mean power output and a greater fatigue index in the carbohydrate vs. placebo trial.Serial administration of a carbohydrate mouth rinse may be beneficial for

  8. Self-etch and etch-and-rinse adhesive systems in clinical dentistry.

    Science.gov (United States)

    Ozer, Fusun; Blatz, Markus B

    2013-01-01

    Current adhesive systems follow either an "etch-and-rinse" or "self-etch" approach, which differ in how they interact with natural tooth structures. Etch-and-rinse systems comprise phosphoric acid to pretreat the dental hard tissues before rinsing and subsequent application of an adhesive. Self-etch adhesives contain acidic monomers, which etch and prime the tooth simultaneously. Etch-and-rinse adhesives are offered as two- or three-step systems, depending on whether primer and bonding are separate or combined in a single bottle. Similarly, self-etch adhesives are available as one- or two-step systems. Both etch-and-rinse and self-etch systems form a hybrid layer as a result of resins impregnating the porous enamel or dentin. Despite current trends toward fewer and simpler clinical application steps, one-step dentin bonding systems exhibit bonding agent lower bond strengths and seem less predictable than multi-step etch-and-rinse and self-etch systems. The varying evidence available today suggests that the choice between etch-and-rinse and self-etch systems is often a matter of personal preference. In general, however, phosphoric acid creates a more pronounced and retentive etching pattern in enamel. Therefore, etch-and-rinse bonding systems are often preferred for indirect restorations and when large areas of enamel are still present. Conversely, self-etch adhesives provide superior and more predictable bond strength to dentin and are, consequently, recommended for direct composite resin restorations, especially when predominantly supported by dentin.

  9. Effects of caffeine and carbohydrate mouth rinses on repeated sprint performance.

    Science.gov (United States)

    Beaven, C Martyn; Maulder, Peter; Pooley, Adrian; Kilduff, Liam; Cook, Christian

    2013-06-01

    Our purpose was to examine the effectiveness of carbohydrate and caffeine mouth rinses in enhancing repeated sprint ability. Previously, studies have shown that a carbohydrate mouth rinse (without ingestion) has beneficial effects on endurance performance that are related to changes in brain activity. Caffeine ingestion has also demonstrated positive effects on sprint performance. However, the effects of carbohydrate or caffeine mouth rinses on intermittent sprints have not been examined previously. Twelve males performed 5 × 6-s sprints interspersed with 24 s of active recovery on a cycle ergometer. Twenty-five milliliters of either a noncaloric placebo, a 6% glucose, or a 1.2% caffeine solution was rinsed in the mouth for 5 s prior to each sprint in a double-blinded and balanced cross-over design. Postexercise maximal heart rate and perceived exertion were recorded, along with power measures. A second experiment compared a combined caffeine-carbohydrate rinse with carbohydrate only. Compared with the placebo mouth rinse, carbohydrate substantially increased peak power in sprint 1 (22.1 ± 19.5 W; Cohen's effect size (ES), 0.81), and both caffeine (26.9 ± 26.9 W; ES, 0.71) and carbohydrate (39.1 ± 25.8 W; ES, 1.08) improved mean power in sprint 1. Experiment 2 demonstrated that a combination of caffeine and carbohydrate improved sprint 1 power production compared with carbohydrate alone (36.0 ± 37.3 W; ES, 0.81). We conclude that carbohydrate and (or) caffeine mouth rinses may rapidly enhance power production, which could have benefits for specific short sprint exercise performance. The ability of a mouth-rinse intervention to rapidly improve maximal exercise performance in the absence of fatigue suggests a central mechanism.

  10. Experimental and numerical study of heat transfer phenomena, inside a flat-plate integrated collector storage solar water heater (ICSSWH), with indirect heat withdrawal

    International Nuclear Information System (INIS)

    Gertzos, K.P.; Pnevmatikakis, S.E.; Caouris, Y.G.

    2008-01-01

    The thermal behavior of a particular flat-plate integrated collector storage solar water heater (ICSSWH) is examined, experimentally and numerically. The particularity consists of the indirect heating of the service hot water, through a heat exchanger incorporated into front and back major surfaces of the ICSSWH. Natural and forced convection mechanisms are both examined. A prototype tank was fabricated and experimental data of temperature profiles are extracted, during various energy withdrawals. A 3D computational fluid dynamics (CFD) model was developed and validated against experimental results. Numerical predictions are found highly accurate, providing thus the use of the 3D CFD model for the optimization of this and similar devices

  11. Polyethylene glycol rinse solution: An effective way to prevent ischemia-reperfusion injury

    Science.gov (United States)

    Zaouali, Mohamed Amine; Bejaoui, Mohamed; Calvo, Maria; Folch-Puy, Emma; Pantazi, Eirini; Pasut, Gianfranco; Rimola, Antoni; Ben Abdennebi, Hassen; Adam, René; Roselló-Catafau, Joan

    2014-01-01

    AIM: To test whether a new rinse solution containing polyethylene glycol 35 (PEG-35) could prevent ischemia-reperfusion injury (IRI) in liver grafts. METHODS: Sprague-Dawley rat livers were stored in University of Wisconsin preservation solution and then washed with different rinse solutions (Ringer’s lactate solution and a new rinse solution enriched with PEG-35 at either 1 or 5 g/L) before ex vivo perfusion with Krebs-Heinseleit buffer solution. We assessed the following: liver injury (transaminase levels), mitochondrial damage (glutamate dehydrogenase activity), liver function (bile output and vascular resistance), oxidative stress (malondialdehyde), nitric oxide, liver autophagy (Beclin-1 and LCB3) and cytoskeleton integrity (filament and globular actin fraction); as well as levels of metalloproteinases (MMP2 and MMP9), adenosine monophosphate-activated protein kinase (AMPK), heat shock protein 70 (HSP70) and heme oxygenase 1 (HO-1). RESULTS: When we used the PEG-35 rinse solution, reduced hepatic injury and improved liver function were noted after reperfusion. The PEG-35 rinse solution prevented oxidative stress, mitochondrial damage, and liver autophagy. Further, it increased the expression of cytoprotective heat shock proteins such as HO-1 and HSP70, activated AMPK, and contributed to the restoration of cytoskeleton integrity after IRI. CONCLUSION: Using the rinse solution containing PEG-35 was effective for decreasing liver graft vulnerability to IRI. PMID:25473175

  12. The Influence of Serial Carbohydrate Mouth Rinsing on Power Output during a Cycle Sprint

    Directory of Open Access Journals (Sweden)

    Shaun M. Phillips, Scott Findlay, Mykolas Kavaliauskas, Marie Clare Grant

    2014-06-01

    Full Text Available The objective of the study was to investigate the influence of serial administration of a carbohydrate (CHO mouth rinse on performance, metabolic and perceptual responses during a cycle sprint. Twelve physically active males (mean (± SD age: 23.1 (3.0 years, height: 1.83 (0.07 m, body mass (BM: 86.3 (13.5 kg completed the following mouth rinse trials in a randomized, counterbalanced, double-blind fashion; 1. 8 x 5 second rinses with a 25 ml CHO (6% w/v maltodextrin solution, 2. 8 x 5 second rinses with a 25 ml placebo (PLA solution. Following mouth rinse administration, participants completed a 30 second sprint on a cycle ergometer against a 0.075 g·kg-1 BM resistance. Eight participants achieved a greater peak power output (PPO in the CHO trial, resulting in a significantly greater PPO compared with PLA (13.51 ± 2.19 vs. 13.20 ± 2.14 W·kg-1, p 0.05. No significant between-trials difference was reported for fatigue index, perceived exertion, arousal and nausea levels, or blood lactate and glucose concentrations. Serial administration of a CHO mouth rinse may significantly improve PPO during a cycle sprint. This improvement appears confined to the first 5 seconds of the sprint, and may come at a greater relative cost for the remainder of the sprint.

  13. Mouth rinsing improves cycling endurance performance during Ramadan fasting in a hot humid environment.

    Science.gov (United States)

    Che Muhamed, Ahmad Munir; Mohamed, Nazirah Gulam; Ismail, Norjana; Aziz, Abdul Rashid; Singh, Rabindarjeet

    2014-04-01

    This study examined the effect of mouth rinsing during endurance cycling in a hot humid environment (32 °C and 75% relative humidity) on athletes in the Ramadan fasted state. Nine trained adolescent male cyclists completed 3 trials that consisted of a carbohydrate mouth-rinse (CMR), a placebo mouth-rinse (PMR), and a no-rinse (NOR) trial during the last 2 weeks of Ramadan. Each trial consisted of a preloading cycle at 65% peak rate of oxygen consumption for 30 min followed by a 10-km time trial (TT10 km) under hot humid condition. During the CMR and PMR trials, each cyclist rinsed his mouth with 25 mL of the solution for 5 s before expectorating the solution pre-exercise, after 5, 15, and 25 min of the preloading cycle, and 15 s prior to the start of TT10 km. Time to complete the TT10 km was significantly faster in the CMR and PMR trials compared with the NOR trial (12.9 ± 1.7 and 12.6 ± 1.7 vs. 16.8 ± 1.6 min, respectively; p benefits compared with a no-rinse condition on TT10 km performance in acute Ramadan fasted subjects during endurance cycling in a heat stress environment.

  14. Experimental analysis of solar thermal integrated MD system for cogeneration of drinking water and hot water for single family villa in dubai using flat plate and evacuated tube solar collectors

    DEFF Research Database (Denmark)

    Asim, Muhammad; Imran, Muhammad; Leung, Michael K.H.

    2017-01-01

    This paper presents the experimental analysis performed on solar thermal integrated membrane distillation (MD) system using flat plate and evacuated tube collectors. The system will be utilized for cogeneration of drinking water and domestic hot water for single family in Dubai comprising of four...... to five members. Experiments have been performed in Ras Al Khaimah Research and Innovation Centre (RAKRIC) facility. The experimental setup has been installed to achieve the required production of 15–25 L/d of drinking water and 250 L/d of hot water for domestic purposes. Experiments have been performed...

  15. Cleaning by Surfactant Gradients: Particulate Removal from Porous Materials and the Significance of Rinsing in Laundry Detergency

    Science.gov (United States)

    Shin, Sangwoo; Warren, Patrick B.; Stone, Howard A.

    2018-03-01

    Removing particles from fibrous materials involves loosening via surfactants followed by particle transfer in a flow. While flow advection is commonly believed to be the major driver for pore-scale transport, small pores within the fabric do not allow any significant fluid flow inside them, thus significantly reducing the role of advection. However, rinsing the fabric with fresh water naturally establishes a surfactant gradient within the pore space, providing a suitable environment for particles to undergo diffusiophoresis. We demonstrate that this mechanism can remove particles from deep within fabric pores at an accelerated rate. The nonlinear aspect of diffusiophoresis significantly prolongs the lifetime of the phoretic motion beyond the naive solute diffusion time scale during rinsing, allowing long-lasting, continuous removal of particles. Moreover, owing to the fine balance between chemiphoresis and electrophoresis for particles in anionic surfactant concentration gradients, we show that the particle removal is sensitive to the counterion mobility, suggesting a simple route to control the effect. We thus claim to have resolved the "stagnant core problem"—a long-standing mystery in laundry detergency—and have identified a physicochemical approach to particle transport in fibrous media with broad applicability.

  16. The effect of using nano-silver dispersed water based nanofluid as a passive method for energy efficiency enhancement in a plate heat exchanger

    International Nuclear Information System (INIS)

    Behrangzade, Ali; Heyhat, Mohammad Mahdi

    2016-01-01

    Highlights: • The effect of using nano-silver on a commercial plate heat exchanger was studied. • An experimental rig was designed to investigate the thermo-hydrodynamic features of nanofluid. • The overall heat transfer coefficient becomes larger 16.79% for 100 ppm nanofluid. • No significant growth in pressure drop values was observed. • The process temperatures have important role in nanofluid influence. - Abstract: The purpose of this study is to verify the potential using of nano-silver dispersed water based nanofluid on efficiency improvement of a commercial corrugated plate heat exchanger. In this regards, an experimental rig was provided to recognize the heat transfer rate and pressure drop of Ag–water nanofluid as the working fluid. The two most key thermo-physical properties, i.e. dynamic viscosity and thermal conductivity of nanofluids were experimentally gauged. The findings, which were achieved, displayed that the overall heat transfer coefficient becomes larger, from 6.18% to 16.79%, for 100 ppm silver nanofluid. While using nanofluid, no significant growth in pressure drop values was observed. Moreover, the process temperatures and flow rates have significant impacts on the helpfulness of applying nanofluid in a plate heat exchanger.

  17. Waffle production: influence of batter ingredients on sticking of waffles at baking plates-Part II: effect of fat, leavening agent, and water.

    Science.gov (United States)

    Huber, Regina; Schoenlechner, Regine

    2017-05-01

    Fresh egg waffles are continuously baked in tunnel baking ovens in industrial scale. Waffles that partly or fully stick to the baking plates cause significant product loss and increased costs. The aim of this study was, therefore, to investigate the effect of different recipe ingredients on the sticking behavior of waffles. In this second part, ingredients investigated were different leavening agents (sodium acid pyrophosphate, ammonium bicarbonate, magnesium hydroxide carbonate, or monocalcium phosphate), different fat sources (rapeseed oil, cocos fat, butter, or margarine), and different water sources (tap water 12°dH and distilled water). Within the different types of fats, solid fats with high amount of short-chain fatty acids (cocos fat or butter) decreased the number of sticking waffles compared to liquid oils (rapeseed oil). Regarding leavening agents, magnesium hydroxide carbonate and ammonium bicarbonate were superior to sodium acid pyrophosphate or monocalcium phosphate. Between the two water sources, effects were small.

  18. Optimal design and placement of serpentine heat exchangers for indirect heat withdrawal, inside flat plate integrated collector storage solar water heaters (ICSSWH)

    Energy Technology Data Exchange (ETDEWEB)

    Gertzos, K.P.; Caouris, Y.G.; Panidis, T. [Dept. of Mechanical Engineering and Aeronautics, University of Patras, 265 00 Patras (Greece)

    2010-08-15

    Parameters that affect the temperature at which service hot water (SHW) is offered by an immersed tube heat exchanger (HX), inside a flat plate Integrated Collector Storage Solar Water Heater (ICSSWH), are examined numerically, by means of Computational Fluid Dynamics (CFD) analysis. The storage water is not refreshed and serves for heat accumulation. Service hot water is drawn off indirectly, through an immersed serpentine heat exchanger. For the intensification of the heat transfer process, the storage water is agitated by recirculation through a pump, which goes on only when service water flows inside the heat exchanger. Three main factors, which influence the performance, are optimized: The position of the HX relative to tank walls, the HX length and the tube diameter. All three factors are explored so that to maximize the service water outlet temperature. The settling time of the optimum configuration is also computed. Various 3-D CFD models were developed using the FLUENT package. The heat transfer rate between the two circuits of the optimum configuration is maintained at high levels, leading to service water outlet temperatures by 1-7 C lower than tank water temperatures, for the examined SHW flow rates. The settling time is retained at sufficient law values, such as 20 s. The optimal position was found to lay the HX in contact with the front and back walls of the tank, with an optimum inner tube diameter of 16 mm, while an acceptable HX length was found to be about 21.5 m. (author)

  19. Effect of tetracycline on the bond performance of etch-and-rinse adhesives to dentin

    Directory of Open Access Journals (Sweden)

    Rodrigo Stanislawczuk

    2011-10-01

    Full Text Available This study evaluated the effect of modified tetracycline on the resin-dentin bond strength (µTBS, silver nitrate uptake (SNU and solution homogeneity (SH of two adhesives. Dentin surfaces were treated with phosphoric acid, rinsed off and either rewetted with water (control group - CO, 2% minocycline (MI, 2% doxycyline (DO or 2% chlorhexidine (CH. Adhesive systems (Adper Single Bond 2 and Prime Bond NT and composite were applied and light-polymerized. Specimens were sectioned to obtain bonded sticks (0.8 mm² to test under tension at 0.5 mm/min. For SNU, specimens were immersed in silver nitrate and analyzed by EDX-SEM. SH was qualitatively analyzed after mixing the adhesives with different solvent-based solutions containing MI, DO and CH. Lower µTBS values were observed in the DO group compared with MI and CH (p = 0.01. Lower SNU was observed for MI and CH. The lowest µTBS for both adhesives was observed for the DO group (p = 0.01. Signs of phase separation were observed for DO with both adhesives. MI or CH used as rewetting solutions after acid etching did not affect the µTBS and hybrid layer quality.

  20. "Rinse and trickle": a protocol for TEM preparation and investigation of inorganic fibers from biological material.

    Science.gov (United States)

    Vigliaturo, Ruggero; Capella, Silvana; Rinaudo, Caterina; Belluso, Elena

    2016-07-01

    The purpose of this work is to define a sample preparation protocol that allows inorganic fibers and particulate matter extracted from different biological samples to be characterized morphologically, crystallographically and chemically by transmission electron microscopy-energy dispersive spectroscopy (TEM-EDS). The method does not damage or create artifacts through chemical attacks of the target material. A fairly rapid specimen preparation is applied with the aim of performing as few steps as possible to transfer the withdrawn inorganic matter onto the TEM grid. The biological sample is previously digested chemically by NaClO. The salt is then removed through a series of centrifugation and rinse cycles in deionized water, thus drastically reducing the digestive power of the NaClO and concentrating the fibers for TEM analysis. The concept of equivalent hydrodynamic diameter is introduced to calculate the settling velocity during the centrifugation cycles. This technique is applicable to lung tissues and can be extended to a wide range of organic materials. The procedure does not appear to cause morphological damage to the fibers or modify their chemistry or degree of crystallinity. The extrapolated data can be used in interdisciplinary studies to understand the pathological effects caused by inorganic materials.

  1. Photocatalytic degradation of dissolved organic matter in the ground water employing TiO2 film supported on stainless steel plate

    International Nuclear Information System (INIS)

    Andayani, W.; Sumartono, A.; Lindu, M.

    2012-01-01

    The Taman Palem Residences, Cengkareng, Indonesia has a groundwater problem as a main sources of drinking water in the area due to yellowish brown colour of the water, that may come from dissolved organic matter (DOM), humic substances. Photocatalytic degradation using TiO 2 coated on a stainless steel plate (8 x 8 cm) to degrade the dissolved organic matter was studied. Groundwater samples were collected at 150 m deep from Taman Palem Residences. The TiO 2 catalyst was made from deep coating in a sol-gel system of titanium (IV) diisopropoxidebisacetylacetonate (TAA) precursor and immobilized at stainless steel plate (8 x 8 cm), followed by calcination at 525°C. Two catalyst sheets were put in batch reactor containing groundwater. The ground water containing DOM were irradiated by UV black light at varying initial pH values i.e 5, 7 and 9. Sampling of solution was taken at the interval time of 0, 1, 2, 4, and 6 hours. DOM residu in water before and after irradiation were measured by spectrophotometer UV-Vis at 300 nm. Photocatalytic degradation of DOM was greater in acid solution than in basic solution. The determination of intermediate degradation products by HPLC revealed that oxalic acid was detected consistently. (author)

  2. Bipolar Plates for PEM Systems

    OpenAIRE

    Lædre, Sigrid

    2016-01-01

    Summary of thesis: The Bipolar Plate (BPP) is an important component in both Proton Exchange Membrane Fuel Cells (PEMFCs) and Proton Exchange Membrane Water Electrolyzers (PEMWEs). Bipolar plate material and processing constitutes for a large fraction of the cost and weight of a PEM cell stack. The main tasks for the bipolar plates in both systems are to separate single cell in a stack, conduct current between single cells and remove heat from active areas. In addition, the BPPs distribu...

  3. Study of the influence of water properties dependency with the temperature in a laminar downward flow between parallel flat plates

    International Nuclear Information System (INIS)

    Delmastro, Dario F.; Chasseur, A.F.; Garcia, Juan C.

    2007-01-01

    In this work we develop a model that contemplates stationary completely developed laminar downward flow between flat parallel plates with uniform and constant heat fluxes. The Boussinesq approach is used in the momentum equation, taking into account the change of the density with the temperature only in the gravitational term. The system is at atmospheric pressure and the dependencies of the density and the thermal conductivity with the temperature are also considered. The velocity and temperature profiles, the friction factor, the heat transfer coefficient and the Nusselt Number are calculated, for different flow rates and heating powers. The results allow to obtain some conclusions that can be of interest in the study of research reactors with forced downward refrigeration and flat plate fuels, although these calculations do not exactly represent the real behavior inside these channels. (author) [es

  4. Efficacy of a probiotic and chlorhexidine mouth rinses: A short-term clinical study

    Directory of Open Access Journals (Sweden)

    Harini P

    2010-09-01

    Full Text Available Introduction: Probiotic technology represents a breakthrough approach to maintaining oral health by utilizing natural beneficial bacteria commonly found in healthy mouths to provide a natural defense against those bacteria thought to be harmful to teeth and gums. However, data are still sparse on the probiotic action in the oral cavity. The review article on probiotics in children published by Twetman and Stecksen- Blicks in 2008 showed only one study of dental interest on probiotics in children. Aim and Objectives: The present study evaluated clinically the efficacy of a probiotic and chlorhexidine mouth rinses on plaque and gingival accumulation in children. The trial design is a double-blind parallel group, 14 days comparative study between a probiotic mouth rinse and a chlorhexidine mouth rinse, which included 45 healthy children in the age group of 6-8 years. Results: The Probiotic and Chlorhexidine groups had less plaque accumulations compared with the Control group at the end of 14 years (P < 0.001 and P < 0.001, respectively. But, unlike the plaque score, there was a significant difference in the Gingival Index between the Probiotic and the Chlorhexidine groups (P = 0.009, Probiotic group being better than the Chlorhexidine group (mean = 0.2300 and 0.6805, respectively. Conclusion: The Probiotic mouth rinse was found effective in reducing plaque accumulation and gingival inflammation. Therefore, probiotic mouth rinse obviously has a potential therapeutic value and further long-term study is recommended to determine its efficacy.

  5. Microbiological assessment of house and imported bottled water by comparison of bacterial endotoxin concentration, heterotrophic plate count, and fecal coliform count.

    Science.gov (United States)

    Reyes, Mayra I; Pérez, Cynthia M; Negrón, Edna L

    2008-03-01

    Consumers increasingly use bottled water and home water treatment systems to avoid direct tap water. According to the International Bottled Water Association (IBWA), an industry trade group, 5 billion gallons of bottled water were consumed by North Americans in 2001. The principal aim of this study was to assess the microbial quality of in-house and imported bottled water for human consumption, by measurement and comparison of the concentration of bacterial endotoxin and standard cultivable methods of indicator microorganisms, specifically, heterotrophic and fecal coliform plate counts. A total of 21 brands of commercial bottled water, consisting of 10 imported and 11 in-house brands, selected at random from 96 brands that are consumed in Puerto Rico, were tested at three different time intervals. The Standard Limulus Amebocyte Lysate test, gel clot method, was used to measure the endotoxin concentrations. The minimum endotoxin concentration in 63 water samples was less than 0.0625 EU/mL, while the maximum was 32 EU/mL. The minimum bacterial count showed no growth, while the maximum was 7,500 CFU/mL. Bacterial isolates like P. fluorescens, Corynebacterium sp. J-K, S. paucimobilis, P. versicularis, A. baumannii, P. chlororaphis, F. indologenes, A. faecalis and P. cepacia were identified. Repeated measures analysis of variance demonstrated that endotoxin concentration did not change over time, while there was a statistically significant (p bacterial count over time. In addition, multiple linear regression analysis demonstrated that a unit change in the concentration of endotoxin across time was associated with a significant (p bacterial growth was not detected in some water samples, endotoxin was present. Measurement of Gram-negative bacterial endotoxins is one of the methods that have been suggested as a rapid way of determining bacteriological water quality.

  6. Rinse-resistant superhydrophobic block copolymer fabrics by electrospinning, electrospraying and thermally-induced self-assembly

    Science.gov (United States)

    Wu, Jie; Li, Xin; Wu, Yang; Liao, Guoxing; Johnston, Priscilla; Topham, Paul D.; Wang, Linge

    2017-11-01

    An inherent problem that restricts the practical application of superhydrophobic materials is that the superhydrophobic property is not sustainable; it can be diminished, or even lost, when the surface is physically damaged. In this work, we present an efficient approach for the fabrication of superhydrophobic fibrous fabrics with great rinse-resistance where a block copolymer has been electrospun into a nanofibrous mesh while micro-sized beads have been subsequently electrosprayed to give a morphologically composite material. The intricate nano- and microstructure of the composite was then fixed by thermally annealing the block copolymer to induce self-assembly and interdigitation of the microphase separated domains. To demonstrate this approach, a polystyrene-b-poly(ethylene-co-butylene)-b-polystyrene (SEBS) nanofibrous scaffold was produced by electrospinning before SEBS beads were electrosprayed into this mesh to form a hierarchical micro/nanostructure of beads and fibers. The effects of type and density of SEBS beads on the surface morphology and wetting properties of composite membranes were studied extensively. Compared with a neat SEBS fibrous mesh, the composite membrane had enhanced hydrophobic properties. The static water contact angle increased from 139° (±3°) to 156° (±1°), while the sliding angle decreased to 8° (±1°) from nearly 90°. In order to increase the rinse-resistance of the composite membrane, a thermal annealing step was applied to physically bind the fibers and beads. Importantly, after 200 h of water flushing, the hierarchical surface structure and superhydrophobicity of the composite membrane were well retained. This work provides a new route for the creation of superhydrophobic fabrics with potential in self-cleaning applications.

  7. NICKEL PLATING PROCESS

    Science.gov (United States)

    Hoover, T.B.; Zava, T.E.

    1959-05-12

    A simplified process is presented for plating nickel by the vapor decomposition of nickel carbonyl. In a preferred form of the invention a solid surface is nickel plated by subjecting the surface to contact with a mixture containing by volume approximately 20% nickel carbonyl vapor, 2% hydrogen sulfide and .l% water vapor or 1% oxygen and the remainder carbon dioxide at room temperature until the desired thickness of nickel is obtained. The advantage of this composition over others is that the normally explosive nickel carbonyl is greatly stabilized.

  8. Saliva secretion difference before and after rinsing with baking soda on menopause women

    Directory of Open Access Journals (Sweden)

    Dewi Anggraeni

    2007-03-01

    Full Text Available Menopause women can experience a decrease in saliva secretion (decrease. To understand the clear picture about saliva secretion, the volume, flow rate, pH and viscosity were then measured. The aim of this research was to obtain a picture about the difference of saliva secretion before and after rinsing with baking soda on menopause women. The type of the research used was a laboratory quasi-experiment with comparative descriptive form. The technique used in this research is the survey method, and samples were taken using the multistage cluster random sampling method, and t-student statistical analysis. This research was conducted with the saliva collected with spitting method on 45 menopause women. The results show that the average volume, flow rate, pH and viscosity before rinsing with baking soda was 1.79 ml, 0.18 ml/minute, 7.40 and 0.81 mm2/second. The average volume, flow rate, pH and viscosity after rinsing with baking soda were 2.66 ml; 0.27 ml/minute; 8.67 and 0.78 mm2/second. Statistical analysis t-student on α = 0.05 shows volume changes, flow rate, pH and saliva viscosity before and after rinsing with baking soda was 0.873; 0.086; 1.273 and 0.037 respectively. The conclusion shows a significant difference between saliva secretion before and after rinsing with baking soda, and saliva secretion after rinsing with baking soda on menopause women.

  9. Comparison of Pore-scale CO2-water-glass System Wettability and Conventional Wettability Measurement on a Flat Plate for Geological CO2 Sequestration

    Science.gov (United States)

    Jafari, M.; Cao, S. C.; Jung, J.

    2017-12-01

    Goelogical CO2 sequestration (GCS) has been recently introduced as an effective method to mitigate carbon dioxide emission. CO2 from main producer sources is collected and then is injected underground formations layers to be stored for thousands to millions years. A safe and economical storage project depends on having an insight of trapping mechanisms, fluids dynamics, and interaction of fluids-rocks. Among different forces governing fluids mobility and distribution in GCS condition, capillary pressure is of importance, which, in turn, wettability (measured by contact angel (CA)) is the most controversial parameters affecting it. To explore the sources of discrepancy in the literature for CA measurement, we conducted a series of conventional captive bubble test on glass plates under high pressure condition. By introducing a shape factor, we concluded that surface imperfection can distort the results in such tests. Since the conventional methods of measuring the CA is affected by gravity and scale effect, we introduced a different technique to measure pore-scale CA inside a transparent glass microchip. Our method has the ability to consider pore sizes and simulate static and dynamics CA during dewetting and imbibition. Glass plates shows a water-wet behavior (CA 30° - 45°) by a conventional experiment consistent with literature. However, CA of miniature bubbles inside of the micromodel can have a weaker water-wet behavior (CA 55° - 69°). In a more realistic pore-scale condition, water- CO2 interface covers whole width of a pore throats. Under this condition, the receding CA, which is used for injectability and capillary breakthrough pressure, increases with decreasing pores size. On the other hand, advancing CA, which is important for residual or capillary trapping, does not show a correlation with throat sizes. Static CA measured in the pores during dewetting is lower than static CA on flat plate, but it is much higher when measured during imbibition implying

  10. Influence of elastomeric seal plate surface chemistry on interface integrity in biofouling-prone systems: Evaluation of a hydrophobic "easy-release" silicone-epoxy coating for maintaining water seal integrity of a sliding neoprene/steel interface

    Science.gov (United States)

    Andolina, Vincent L.

    Attenuated Internal Reflection (MAIR-IR) and Microscopic Infrared Spectroscopy for organic surface compositional details, light microscopy for wear area quantification, and profilometry for surface roughness estimation and wear depth quantification. Pin-on-disc dynamic Coefficient of Friction (CoF) measurements provided data relevant to forecasts of seal integrity in dry, wet and biofouling-influenced sliding contact. Actual wear of neoprene seal material against uncoated and coated steel surfaces, wet and dry, was monitored after both rotary and linear cyclic wear testing, demonstrating significant reductions in elastomer wear areas and depths (and resultant volumes) when the coating was present. Coating the steel eliminated a 270% increase in neoprene surface area wear and an 11-fold increase in seal abrasive volume loss associated with underwater rusting in rotary experiments. Linear testing results confirm coating efficacy by reducing wear area in both loading regimes by about half. No coating delamination was observed, apparently due to a differential distribution of silicone and epoxy ingredients at the air-exposed vs. steel-bonded interfaces demonstrated by IR and EDS methods. Frictional testing revealed higher Coefficients of Friction (CoF) associated with the low-speed sliding of Neoprene over coated rather than uncoated steel surfaces in a wet environment, indicating better potential seal adhesion between the hydrophobic elastomer and coating than between the elastomer and intrinsically hydrophilic uncoated steel. When zebra mussel biofouling debris was present in the articulating joints, CoF was reduced as a result of a water channel path produced between the articulating surfaces by the retained biological matter. Easier release of the biofouling from the low-CST coated surfaces restored the seal integrity more rapidly with further water rinsing. Rapid sliding diminished these biofouling-related differences, but revealed a significant advantage in reducing the Co

  11. Mechanical properties and modeling of drug release from chlorhexidine-containing etch-and-rinse adhesives.

    Science.gov (United States)

    Stanislawczuk, Rodrigo; Reis, Alessandra; Malaquias, Pamela; Pereira, Fabiane; Farago, Paulo Vitor; Meier, Marcia Margarete; Loguercio, Alessandro D

    2014-04-01

    To evaluate the effects of chlorhexidine (CHX) addition in different concentrations into simplified etch-and-rinse adhesives on the ultimate tensile strength (UTS), water sorption (WS), solubility (SO) and the rate of CHX release over time. We added CHX diacetate to Ambar [AM] (FGM) and XP Bond [XP] (Dentsply) in concentrations of 0, 0.01, 0.05, 0.1 and 0.2 wt%. For UTS (n=10 for each group), adhesive specimens were constructed in an hourglass shape metallic matrix with cross-sectional area of 0.8 mm(2). Half of specimens were tested after 24 h and the other half after 28 days of water storage in tension of 0.5 mm/min. For WS and SO (n=10 for each group), adhesive discs (5.8 mm×1.0 mm) were prepared into a mold. After desiccation, we weighed and stored the cured adhesive specimens in distilled water for evaluation of the WS, SO and the cumulative release of CHX over a 28-day period. For CHX release (n=10 for each group), spectrophotometric measurements of storage solution were performed to examine the release kinetics of CHX. We subjected data from each test to ANOVA and Tukey' test (α=0.05). XP Bond adhesive showed significantly more WS and SO and lower UTS than Ambar. In general, the addition of CHX did not alter WS, SO and UTS of the adhesives. XP showed a higher CHX release than AM (p<0.05) in all concentrations and the final amount of CHX release was directly proportional to the initial CHX concentration added to the adhesives. After 28 days of water storage, approximately 20% of CHX was released from XP and 8.0-12.0% from AM. Addition of CHX to commercial adhesive is a feasible method to provide a controlled release of CHX over time without jeopardizing WS, SO and UTS of the adhesives. Manufacturers should consider adding CHX to commercial adhesives to provide a controlled release of CHX over time. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  12. Bottom nozzle for nuclear reactor fuel assembly having an adaptor plate and a coupled filtration plate

    International Nuclear Information System (INIS)

    Verdier, M.; Mortgat, R.

    1992-01-01

    The bottom nozzle includes an adaptor plate with openings to allow the passage of water and a filtration plate with small holes. The openings in the adaptor plate are symmetrical with regard to medians and diagonals. Within each zone, some of the openings are rectangular and some may be circular. The small holes in the filtration plate coincide with the rectangular openings in the adaptor plate

  13. Efficacy of different brands of mouth rinses on oral bacterial load ...

    African Journals Online (AJOL)

    Subjects were divided into 3 groups and their saliva samples were assessed for microbial counts at the beginning and the end of an eight-week period during which they rinsed with 10ml of mouthrinse for 15 seconds twice daily (morning and evening) in addition to their usual oral hygiene procedures.The results showed ...

  14. Application of a capsaicin rinse in the treatment of burning mouth syndrome

    Science.gov (United States)

    Silvestre-Rangil, Javier; Tamarit-Santafé, Carmen; Bautista, Daniel

    2012-01-01

    Objective: To examine the efficacy of a new topical capsaicin presentation as an oral rinse in improving the symptoms of burning mouth syndrome (BMS). Study design: A prospective, double-blind, cross-over study was made of 30 patients with BMS. There were 7 dropouts; the final study series thus comprised 23 individuals. The patients were randomized to two groups: (A) capsaicin rinse (0.02%) or (B) placebo rinse, administered during one week. After a one-week washout period, the patients were then assigned to the opposite group. Burning discomfort was scored using a visual analog scale (VAS): in the morning before starting the treatment, in the afternoon on the first day of treatment, and at the end of the week of treatment in the morning and in the afternoon. The same scoring sequence was again applied one week later with the opposite rinse. Results: The mean patient age was 72.65 ± 12.10 years, and the duration of BMS was 5.43 ± 3.23 years on average. Significant differences in VAS score were recorded in the capsaicin group between baseline in the morning (AM1) or afternoon (AA1) and the end of the week of treatment (AA7)(p=0.003 and p=0.002, respectively). Conclusion: The topical application of capsaicin may be useful in treating the discomfort of BMS, but has some limitations. Key words: Burning mouth syndrome, stomatodynia, capsaicin, treatment, clinical management. PMID:21743415

  15. Heat transfer and pressure drop characteristics of a plate heat exchanger using water based Al2O3 nanofluid for 30° and 60° chevron angles

    Science.gov (United States)

    Elias, M. M.; Saidur, R.; Ben-Mansour, R.; Hepbasli, A.; Rahim, N. A.; Jesbains, K.

    2018-04-01

    Nanofluid is a new class of engineering fluid that has good heat transfer characteristics which is essential to increase the heat transfer performance in various engineering applications such as heat exchangers and cooling of electronics. In this study, experiments were conducted to compare the heat transfer performance and pressure drop characteristics in a plate heat exchanger (PHE) for 30° and 60° chevron angles using water based Al2O3 nanofluid at the concentrations from 0 to 0.5 vol.% for different Reynolds numbers. The thermo-physical properties has been determined and presented in this paper. At 0.5 vol% concentration, the maximum heat transfer coefficient, the overall heat transfer coefficient and the heat transfer rate for 60° chevron angle have attained a higher percentage of 15.14%, 7.8% and 15.4%, respectively in comparison with the base fluid. Consequently, when the volume concentration or Reynolds number increases, the heat transfer coefficient and the overall heat transfer coefficient as well as the heat transfer rate of the PHE (Plate Heat Exchangers) increases respectively. Similarly, the pressure drop increases with the volume concentration. 60° chevron angle showed better performance in comparison with 30° chevron angle.

  16. Nitrogen oxide absorption into water and dilute nitric acid in an engineering-scale sieve-plate column: description of a mathematical model and comparison with experimental data

    Energy Technology Data Exchange (ETDEWEB)

    Counce, R M

    1978-09-01

    The study reported here is concerned with the absorption of gaseous NO/sub x/ compounds into water and dilute HNO/sub 3/ in a three-stage sieve-plate column with plates designed for high gas-liquid interfacial area. The performance of the column was measured while several operating parameters were varied. A mechanistic model was developed and presented to explain the observed phenomena. The results of the study indicate the importance of three mechanisms in the absorption of gaseous NO/sub x/ compounds: (a) the absorption of NO/sub 2/*, which results in the production of liquid HNO/sub 3/ and HNO/sub 2/; (b) the dissociation of the liquid HNO/sub 2/ into HNO/sub 3/ and gaseous NO; and (c) the gas-phase oxidation of NO to NO/sub 2/. A useful model was developed to explain the absorption of NO/sub x/ compounds based on the above mechanisms. This model is presented and discussed.

  17. The impact of chlorhexidine mouth rinse on the bond strength of polycarbonate orthodontic brackets.

    Science.gov (United States)

    Hussein, Farouk Ahmed; Hashem, Mohammed Ibrahim; Chalisserry, Elna P; Anil, Sukumaran

    2014-11-01

    The purpose of the current in-vivo study was to assess the effect of using 0.12% chlorhexidine (CHX) mouth rinse, before bonding, on shear bond strength of polycarbonate brackets bonded with composite adhesive. Eighteen orthodontic patients with a mean age 21.41 ± 1.2 years, who were scheduled to have 2 or more first premolars extracted, were included in this study. Patients were referred for an oral prophylaxis program which included, in part, the use of a mouth rinse. Patients were divided into 2 groups, a test group of 9 patients who used 0.12% CHX gluconate mouth rinse twice daily and a control group of 9 patients who used a mouth rinse without CHX, but with same color. After 1 week, polycarbonate brackets were bonded to first premolars with Transbond XT composite adhesive. Premolars were extracted after 28 days and tested for shear bond strength on a universal testing machine. Student's t-test was used to compare shear bond strengths of both groups. No statistically significant difference was found in bond strengths' values between both groups. The test group (with CHX) has mean shear bond strength of 14.21 ± 2.42 MPa whereas the control group (without CHX) revealed a mean strength of 14.52 ± 2.31 MPa. The use of 0.12% CHX mouth rinse, for one week before bonding, did not affect the shear bond strength of polycarbonate brackets bonded with Transbond composite. Furthermore, these brackets showed clinically acceptable bond strength.

  18. Mouth Rinsing with Maltodextrin Solutions Fails to Improve Time Trial Endurance Cycling Performance in Recreational Athletes

    Directory of Open Access Journals (Sweden)

    Tuğba Nilay Kulaksız

    2016-05-01

    Full Text Available The carbohydrate (CHO concentration of a mouth rinsing solution might influence the CHO sensing receptors in the mouth, with consequent activation of brain regions involved in reward, motivation and regulation of motor activity. The purpose of the present study was to examine the effects of maltodextrin mouth rinsing with different concentrations (3%, 6% and 12% after an overnight fast on a 20 km cycling time trial performance. Nine recreationally active, healthy males (age: 24 ± 2 years; V ˙ O 2 m a x : 47 ± 5 mL·kg−1·min−1 participated in this study. A double-blind, placebo-controlled randomized study was conducted. Participants mouth-rinsed every 2.5 km for 5 s. Maltodextrin mouth rinse with concentrations of 3%, 6% or 12% did not change time to complete the time trial and power output compared to placebo (p > 0.05. Time trial completion times were 40.2 ± 4.0, 40.1 ± 3.9, 40.1 ± 4.4, and 39.3 ± 4.2 min and power output 205 ± 22, 206 ± 25, 210 ± 24, and 205 ± 23 W for placebo, 3%, 6%, and 12% maltodextrin conditions, respectively. Heart rate, lactate, glucose, and rating of perceived exertion did not differ between trials (p > 0.05. In conclusion, mouth rinsing with different maltodextrin concentrations after an overnight fast did not affect the physiological responses and performance during a 20 km cycling time trial in recreationally active males.

  19. Rhodium target preparation from homemade chloride plating baths used for the industrial cyclotron production of palladium-L03

    International Nuclear Information System (INIS)

    Sadeghi, M.; Van den Winkel, P.; Afarideh, H.; Haji-Saeid, M.; Syrafi Nafis, H.

    2004-01-01

    fitted with a single axial anode, with a bi-directional electromechanical stirrer (1000 rpm, 8/8 sec) and with an isolated resistive circular heating element mounted at the bottom. At the end of the experiment, the plating vessel rinsed abundantly with tap water. Upon removal of the targets, the latter are rinsed with demineralised water and acetone, air-dried and weighed. From this weight, the thickness of the layers is calculated. As Rh-plating to depletion always gives rise to a black coating of the deposit (Rh-black) near the end of the plating, the rhodium layers were cleaned with a scouring suspension (CIF) and a sponge. After rinsing with water and acetone and air-drying, the weight was determined again. Results: From the results it can be concluded: 1. Plating rhodium targets from RhC13 solutions at pH = 1.9 to 2.5 applying a current of 80 to 125 mA per target at 40 degree C, results in (highly) reflective targets requiring no or limited scouring cleaning. Losses during scouring cleaning are then confined to less then 0.5 %; 2. Increasing the current per target to more then 125 mA in the same pH range and at the same temperature, gives rise to increasing losses (up to about 15 % at 200 mA per target) of rhodium during the cleaning process; 3. At lower pH ( 3.0) results in a non-adherent deposit that is completely removed from the Cu-carrier during the cleaning; 4. As far as the thermal shock test is concerned, the deposits satisfies the 250 degree C (= maximum allowable temperature of the rhodium layer during the irradiation) test: quantitative peeling-off and powdering occurs. Conclusions: Electroplated rhodium targets can be prepared from homemade or commercially available chloride baths containing appropriate plating additives. When homemade plating solutions are used, the addition of 1% sulfamic acid is recommended. The pH adjusted to the optimum value (pH = 2) with sodium hydroxide. As plating technique constant current (100 mA/target; 24 hrs) dc

  20. Plate tectonics

    Digital Repository Service at National Institute of Oceanography (India)

    Chaubey, A.K.

    's continental drift theory was later disproved, it was one of the first times that the idea of crustal movement had been introduced to the scientific community; and it has laid the groundwork for the development of modern plate tectonics. In the early... of the structure of the atom was to physical sciences and the theory of evolution was to the life sciences. Tectonics is the study of the forces within the Earth that give rise to continents, ocean basins, mountain ranges, earthquake belts and other large-scale...

  1. Create Your Plate

    Medline Plus

    Full Text Available ... Plate Share Create Your Plate ! Share: Seven Simple Steps to Create Your Plate It's simple and effective ... foods within each food category. Try these seven steps to get started: Using your dinner plate, put ...

  2. Fatigue crack growth characteristics of a533 brade b glass i plate in an environment of high-temperature primary grade nuclear reactor water

    International Nuclear Information System (INIS)

    Mager, T.R.; Moon, D.M.; Landes, J.D.

    1976-01-01

    To characterize the effect of environment on crack growth rate properties of reactor pressure vessel materials, a program was initiated as part of the Heavy Section Steel Technology Program (HSST) to evaluate the effect of Pressurized Water Reactor (PWR) and Boiling Water Reactor (BWR) primary grade coolant environments. The experiments included such variables as frequency, temperature and R ratio. This paper describes the investigation and presents the results of a fracture mechanics evaluation of the fatigue crack growth rate tests of A533 Grade B Class 1 steel plate material in an environment of primary reactor grade water at 550 0 F (288 0 C). A compliance crack growth monitoring technique was utilized to measure the crack growth. The compliance crack length monitor uses a linear variable differential transformer (LVDT) to measure the specimen front face displacement which is converted to crack length by the appropriate compliance calibration curve. The crack growth rate tests were conducted on constant load universal fatigue machines, under sinusoidal tension to tension loading conditions. Tests showed an increase in growth rates at a frequency of 1 cpm over previous results obtained at frequencies of 60 cpm and higher. This increase, the general character of the crack growth rate versus the $DELTA$K curve, and the results from fractographic studies, all indicated that stress corrosion cracking might have occurred for this material and environment. However, a specimen loaded statically in a PWR environment showed no static load crack growth. 13 refs

  3. Experimental validation of dynamic simulation of the flat plate collector in a closed thermosyphon solar water heater

    DEFF Research Database (Denmark)

    Taherian, H.; Kolaei, Alireza Rezania; Sadeghi, S.

    2011-01-01

    This work studies the dynamic simulation of thermosyphon solar water heater collector considering the weather conditions of a city in north of Iran. The simulation was done for clear and partly cloudy days. The useful energy, the efficiency diagrams, the inlet and the outlet of collector, center...

  4. Water flow experiments and analyses on the cross-flow type mercury target model with the flow guide plates

    CERN Document Server

    Haga, K; Kaminaga, M; Hino, R

    2001-01-01

    A mercury target is used in the spallation neutron source driven by a high-intensity proton accelerator. In this study, the effectiveness of the cross-flow type mercury target structure was evaluated experimentally and analytically. Prior to the experiment, the mercury flow field and the temperature distribution in the target container were analyzed assuming a proton beam energy and power of 1.5 GeV and 5 MW, respectively, and the feasibility of the cross-flow type target was evaluated. Then the average water flow velocity field in the target mock-up model, which was fabricated from Plexiglass for a water experiment, was measured at room temperature using the PIV technique. Water flow analyses were conducted and the analytical results were compared with the experimental results. The experimental results showed that the cross-flow could be realized in most of the proton beam path area and the analytical result of the water flow velocity field showed good correspondence to the experimental results in the case w...

  5. Oral rinse as a potential method to culture Candida isolate from AIDS patients

    Directory of Open Access Journals (Sweden)

    Desiana Radithia

    2011-12-01

    Full Text Available Background: Candida isolate is easily sampled from oral cavity by swabbing directly on the candidiasis lesion, to be smeared onto slides for direct examination or cultured in a growth medium. This method is by far the gold standard for defining candidiasis diagnosis. However it is difficult to apply on sensitive patients and almost impossible on patients showing no clinical appearance of oral candidiasis. AIDS patients are very prone to candida infection and have a tendency of repetitive infection involving mixed species. As many candida species show different susceptibility to anti-fungal agents, it is necessary to identify the species causing the infection in the management of oral candidiasis. Oral rinse is a suggested method to obtain candida isolate to be cultured for further analysis such as species identification. This method is simple and less risky on infection transmission as less tools are required in the procedure. Purpose: This study aimed to assess the application of oral rinse as an alternative method to culture Candida isolate from AIDS patients. Methods: A cross-sectional observative study was conducted in HIV/AIDS in-Patient Facility of Intermediate Care Unit for Infection Disease, Dr. Soetomo Hospital Surabaya. Fourteen stadium 4 AIDS patients matching criteria were swabbed on 1/3-posterior of the tongue, and then given 10 ml phosphate buffer saline to rinse vigorously for 15 seconds. Both specimens were cultured on Sabouraud’s dextrose agar and colony growth was observed. Results: Candida colonies were able to grow from all 14 isolates (100% by both methods. Qualitatively, cultures from oral rinse specimens were more populated than cultures from swab specimens. Conclusion: Oral rinse is an applicable technique to obtain Candida species isolate. This technique is safe, easy, non-invasive, and needs less tools therefore less risky for HIV transmission.Latar belakang: Isolat Candida mudah diambil dengan cara mengusap lesi

  6. Development of classification models to detect Salmonella Enteritidis and Salmonella Typhimurium found in poultry carcass rinses by visible-near infrared hyperspectral imaging

    Science.gov (United States)

    Seo, Young Wook; Yoon, Seung Chul; Park, Bosoon; Hinton, Arthur; Windham, William R.; Lawrence, Kurt C.

    2013-05-01

    Salmonella is a major cause of foodborne disease outbreaks resulting from the consumption of contaminated food products in the United States. This paper reports the development of a hyperspectral imaging technique for detecting and differentiating two of the most common Salmonella serotypes, Salmonella Enteritidis (SE) and Salmonella Typhimurium (ST), from background microflora that are often found in poultry carcass rinse. Presumptive positive screening of colonies with a traditional direct plating method is a labor intensive and time consuming task. Thus, this paper is concerned with the detection of differences in spectral characteristics among the pure SE, ST, and background microflora grown on brilliant green sulfa (BGS) and xylose lysine tergitol 4 (XLT4) agar media with a spread plating technique. Visible near-infrared hyperspectral imaging, providing the spectral and spatial information unique to each microorganism, was utilized to differentiate SE and ST from the background microflora. A total of 10 classification models, including five machine learning algorithms, each without and with principal component analysis (PCA), were validated and compared to find the best model in classification accuracy. The five machine learning (classification) algorithms used in this study were Mahalanobis distance (MD), k-nearest neighbor (kNN), linear discriminant analysis (LDA), quadratic discriminant analysis (QDA), and support vector machine (SVM). The average classification accuracy of all 10 models on a calibration (or training) set of the pure cultures on BGS agar plates was 98% (Kappa coefficient = 0.95) in determining the presence of SE and/or ST although it was difficult to differentiate between SE and ST. The average classification accuracy of all 10 models on a training set for ST detection on XLT4 agar was over 99% (Kappa coefficient = 0.99) although SE colonies on XLT4 agar were difficult to differentiate from background microflora. The average classification

  7. Experimental validation of dynamic simulation of the flat plate collector in a closed thermosyphon solar water heater

    International Nuclear Information System (INIS)

    Taherian, H.; Rezania, A.; Sadeghi, S.; Ganji, D.D.

    2011-01-01

    This work studies the dynamic simulation of thermosyphon solar water heater collector considering the weather conditions of a city in north of Iran. The simulation was done for clear and partly cloudy days. The useful energy, the efficiency diagrams, the inlet and the outlet of collector, center of the absorber and center of the glass cover temperatures, were obtained. The simulation results were then compared with the experimental results in fall and showed a good agreement.

  8. Development of a correlation for parameter controlling using exergy efficiency optimization of an Al_2O_3/water nanofluid based flat-plate solar collector

    International Nuclear Information System (INIS)

    Shojaeizadeh, Ehsan; Veysi, Farzad

    2016-01-01

    Highlights: • Exergy efficiency optimization of a flat-plate collector with Al_2O_3 nanofluid is studied. • Solar radiation and ambient temperature are assumed to be uncontrollable. • Solar collector inlet temperature is influenced by the presence of reservoir tank. • A suitable exponential correlation is proposed for the optimized exergy efficiency. • This exponential correlation also is used for controlling independent parameters. - Abstract: The current study deals with the exergy efficiency optimization of an Al_2O_3/water nanofluid-based flat-plate solar collector according to a mathematical optimization (Sequential Quadratic Programming (SQP) method). This study takes into account exergy efficiency optimization when solar radiation and ambient temperature parameters are assumed to be uncontrollable and presented to a wide range of transient data of climatic conditions where these might take place during spring and summer seasons of Kermanshah (Iran), and perform two main cases as follows: (1) the fluid temperature at the inlet of solar collector, T_i, is independent of storage tank (open loop); (2) the fluid temperature at the inlet of solar collector, T_i, is influenced by the presence of storage tank (closed loop). In any conditions of each case studies (working fluid with and without nanoparticles), a suitable decreasing exponential correlation as function of T_a/G_t values (i.e. ambient temperature to solar radiation ratio) is developed for the optimized exergy efficiency and also well controlling independent parameters values (mass flow rate of fluid, nanoparticle volume concentration and collector inlet temperature). Also, it is concluded that each of optimized parameters and the optimum exergy efficiency is of a linear relation with each other.

  9. Wipe-rinse technique for quantitating microbial contamination on large surfaces

    Science.gov (United States)

    Kirschner, L. E.; Puleo, J. R.

    1979-01-01

    The evaluation of an improved wipe-rinse technique for the bioassay of large areas was undertaken due to inherent inadequacies in the cotton swab-rinse technique to which assay of spacecraft is currently restricted. Four types of contamination control cloths were initially tested. A polyester-bonded cloth (PBC) was selected for further evaluation because of its superior efficiency and handling characteristics. Results from comparative tests with PBC and cotton swabs on simulated spacecraft surfaces indicated a significantly higher recovery efficiency for the PBC than for the cotton (90.4 versus 75.2%). Of the sampling area sites studied, PBC was found to be most effective on surface areas not exceeding 0.74 sq m (8.0 sq ft).

  10. Marketingová strategie značky Listerine Smart Rinse

    OpenAIRE

    Vávrová, Helena

    2010-01-01

    The aim of the diploma thesis is to analyse marketing strategy of Listerine Smart Rinse and recommend possible improvements into the future. Theoretical part is divided into three chapters. The first chapter deals with the essence of marketing and definition of marketing process. The second chapter covers brand policy and the importance of brand in marketing. The third chapter offers basic theoretical approaches for the formulation of product, pricing, promotional and distribution strategy wh...

  11. Continuous Process for the Etching, Rinsing and Drying of MEMS Using Supercritical Carbon Dioxide

    Energy Technology Data Exchange (ETDEWEB)

    Min, Seon Ki; Han, Gap Su; You, Seong-sik [Korea University of Technology and Education, Cheonan (Korea, Republic of)

    2015-10-15

    The previous etching, rinsing and drying processes of wafers for MEMS (microelectromechanical system) using SC-CO{sub 2} (supercritical-CO{sub 2}) consists of two steps. Firstly, MEMS-wafers are etched by organic solvent in a separate etching equipment from the high pressure dryer and then moved to the high pressure dryer to rinse and dry them using SC-CO{sub 2}. We found that the previous two step process could be applied to etch and dry wafers for MEMS but could not confirm the reproducibility through several experiments. We thought the cause of that was the stiction of structures occurring due to vaporization of the etching solvent during moving MEMS wafer to high pressure dryer after etching it outside. In order to improve the structure stiction problem, we designed a continuous process for etching, rinsing and drying MEMS-wafers using SC-CO{sub 2} without moving them. And we also wanted to know relations of states of carbon dioxide (gas, liquid, supercritical fluid) to the structure stiction problem. In the case of using gas carbon dioxide (3 MPa, 25 .deg. C) as an etching solvent, we could obtain well-treated MEMS-wafers without stiction and confirm the reproducibility of experimental results. The quantity of rinsing solvent used could be also reduced compared with the previous technology. In the case of using liquid carbon dioxide (3 MPa, 5 .deg. C), we could not obtain well-treated MEMS-wafers without stiction due to the phase separation of between liquid carbon dioxide and etching co-solvent(acetone). In the case of using SC-CO{sub 2} (7.5 Mpa, 40 .deg. C), we had as good results as those of the case using gas-CO{sub 2}. Besides the processing time was shortened compared with that of the case of using gas-CO{sub 2}.

  12. Influence of pre- and post-usage flushing frequencies on bacterial water quality of non-touch water fittings.

    Science.gov (United States)

    Suchomel, Miranda; Diab-Elschahawi, Magda; Kundi, Michael; Assadian, Ojan

    2013-08-30

    Non-touch fittings have been reported to be susceptible for Pseudomonas aeruginosa accumulation. A number of factors may contribute to this, including the frequency of usage, duration of water stagnation, or presence of plastic materials. Programmable non-touch fittings are appearing which allow regular automated post-flushing with cold water to prevent water stagnation. However, the ideal duration of post-flushing is unknown as well as the effect of pre-rinsing with cold water before use. Eight non-touch fittings with brass valve blocks were mounted on a mobile test sink and connected to the same central water pipe source, differing only in presence or absence of water connection pipes, length of connection pipe, frequency of usage, and time intervals for pre- and post-usage water flush. The total bacteria colony-forming unit (cfu) counts were obtained by the spread plate technique. Low frequency of water use in combination with a long stagnating water column resulted in high bacterial cfu counts. Post-usage flushing for 2 seconds did not differ from no flushing. Flushing for 10 seconds with cold water after use or 30 seconds flush before use were both the most effective measures to prevent non-touch fittings from biofilm formation over a period of 20 weeks. Further improvements in water fitting technology could possibly solve the problem of bacterial water contamination in health care settings.

  13. Presence of Antibiotic Resistant Enterococci in Rinses of Milking Equipment after Sanitation Process

    Directory of Open Access Journals (Sweden)

    Miroslav Kročko

    2011-10-01

    Full Text Available Enterococci are common milk contaminants, and microbial contamination of milk by this group of microorganisms can occur from a variety of sources. Significance of enterococci can be assessed by many separated points of view, otherwise a lot of research has focused on the potential role of food enterococci as reservoirs and/or vehicles of antibiotic resistance. The aim of this investigation was to evaluate the occurence of enterococci in rinses of milking equipment (n = 38 on two farms using automatic sanitation system. Our results showed, that alkaline disinfectant (on chlorine basis was effective towards enterococci because apart from 2 samples, their presence in rinses has not been determined. Average number of enterococci survived the aplication of acid disinfectant reached the value 5.00.101 CFU.ml-1. Together, 60 strains were randomly isolated and identified from the grown colonies of genus Enterococcus, and E. faecalis was the predominat species (69.6 %. In rinses, also E. faecium, E. mundtii and undefined enterococci were found. Among antibiotic resistant isolates, 83.9 % of isolates were sensitive to erytromycin (15mcg/disk and resistant to vancomycin (30 mcg/disk were 20 % of isolates.

  14. The effect of three whitening oral rinses on enamel micro-hardness.

    Science.gov (United States)

    Potgieter, E; Osman, Y; Grobler, S R

    2014-05-01

    The purpose of this study was to determine the effect on human enamel micro-hardness of three over-the-counter whitening oral rinses available in South Africa. Enamel fragments were gathered into three groups of 15 each. One group was exposed to Colgate Plax Whitening Blancheur, the second group to White Glo 2 in 1 and the third to Plus White, in each case for periods recommended by the respective manufacturers. Surface micro-hardness of all groups was measured before and after a 14 day treatment period. pH levels of the oral rinses were also determined with a combination pH electrode. Pre- and post- treatment data were analysed by the Wilcoxon Signed Rank Sum Test. According to the micro-hardness values no significant (p > 0.05) enamel damage was found as a result of treatment. However, it was observed that Colgate Pax and White Glo decreased the enamel hardness, an early sign of enamel damage, while Plus White showed a small increase in hardness. The three whitening oral rinses on the South African market do not damage the tooth enamel significantly when used as recommended by the manufacturers. However, extending the contact period and increasing the frequency of application might lead to damage of enamel.

  15. Corrosion fatigue crack growth in clad low-alloy steels. Part 2: Water flow rate effects in high-sulfur plate steel

    International Nuclear Information System (INIS)

    James, L.A.; Lee, H.B.; Wire, G.L.; Novak, S.R.; Cullen, W.H.

    1997-01-01

    Corrosion fatigue crack propagation tests were conducted on a high-sulfur ASTM A302-B plate steel overlaid with weld-deposited Alloy EN82H cladding. The specimens featured semi-elliptical surface cracks penetrating approximately 6.3 mm of cladding into the underlying steel. The initial crack sizes were relatively large with surface lengths of 22.8--27.3 mm, and depths of 10.5--14.1 mm. The experiments were initiated in a quasi-stagnant low-oxygen (O 2 < 10 ppb) aqueous environment at 243 C, under loading conditions (ΔK, R, cyclic frequency) conducive to environmentally assisted cracking (EAC) under quasi-stagnant conditions. Following fatigue testing under quasi-stagnant conditions where EAC was observed, the specimens were then fatigue tested under conditions where active water flow of either 1.7 m/s or 4.7 m/s was applied parallel to the crack. Earlier experiments on unclad surface-cracked specimens of the same steel exhibited EAC under quasi-stagnant conditions, but water flow rates at 1.7 m/s and 5.0 m/s parallel to the crack mitigated EAC. In the present experiments on clad specimens, water flow at approximately the same as the lower of these velocities did not mitigate EAC, and a free stream velocity approximately the same as the higher of these velocities resulted in sluggish mitigation of EAC. The lack of robust EAC mitigation was attributed to the greater crack surface roughness in the cladding interfering with flow induced within the crack cavity. An analysis employing the computational fluid dynamics code, FIDAP, confirmed that frictional forces associated with the cladding crack surface roughness reduced the interaction between the free stream and the crack cavity

  16. Comparison of antimicrobial efficacy of chlorhexidine and combination mouth rinse in reducing the Mutans streptococcus count in plaque

    OpenAIRE

    Laxmi S Lakade; Preetam Shah; Dayanand Shirol

    2014-01-01

    Background: The removal of plaque is utmost important to control dental caries. But in children, factors like lack of dexterity, individual motivation and monitoring limit the effectiveness of tooth brushing. This necessitates the use of chemotherapeutic agents for control of plaque. Aims: To compare the antimicrobial efficacy of 0.2% chlorhexidine mouth rinse and mouth rinse containing 0.03% triclosan, 0.05% sodium fluoride, and 5% xylitol in reducing the Mutans streptococcus count in plaque...

  17. Chemical vs. herbal formulations as pre-procedural mouth rinses to combat aerosol production: A randomized controlled study

    OpenAIRE

    Koduganti Rekha Rani; Manasa Ambati; Jammula Surya Prasanna; Indumathy Pinnamaneni; Panthula Veerendranath Reddy; Dasari Rajashree

    2014-01-01

    Background: Disease transmission and barrier techniques are the key concerns during ultrasonic instrumentation as this procedure has the hazard of aerosol production which has a multitude of deleterious effects on the body. The aerosol produced can affect both the patient and the clinician. The aim of this study was to assess the importance of pre-procedural rinsing before scaling by ultrasonic instrumentation and to compare the efficacy of commercially available herbal mouth rinse and a Chlo...

  18. Effect of Carbohydrate, Caffeine, and Carbohydrate + Caffeine Mouth Rinsing on Intermittent Running Performance in Collegiate Male Lacrosse Athletes.

    Science.gov (United States)

    Dolan, Patrick; Witherbee, Kyle E; Peterson, Kimi M; Kerksick, Chad M

    2017-09-01

    Dolan, P, Witherbee, KE, Peterson, KM, and Kerksick, CM. Effect of carbohydrate, caffeine, and carbohydrate + caffeine mouth rinsing on intermittent running performance in collegiate male lacrosse athletes. J Strength Cond Res 31(9): 2473-2479, 2017-Recently, an interest has developed in the potential to rinse the oral cavity with key nutrients to impact various types of exercise and presumably sporting performance. Although multiple studies examining carbohydrate mouth rinsing have been completed, conflicting evidence surrounding caffeine mouth rinsing persists, and no research has explored its ability to impact high-intensity, intermittent running performance. This study investigated the independent and synergistic ability of carbohydrate and caffeine mouth rinsing to improve intermittent running performance. The Yo-Yo Intermittent Recovery Test-Level 1 (Yo-Yo Level 1) was completed in 10 collegiate (National Collegiate Athletic Association [NCAA] Division II) male lacrosse players after a 10-second mouth rinse with a solution of either carbohydrate (CHO), caffeine (CAF), carbohydrate + caffeine (CHO + CAF), placebo (H2O), or a no rinse control (CON). No significant improvements in Yo-Yo IRT-1 performance were found (p > 0.05). Perceptual indications of effort (i.e., rating of their perceived exertion [RPE]) were significantly lower (p ≤ 0.05) in CHO and CHO + CAF when compared with CON after speed level 11. Interestingly, RPE levels were nonsignificantly lower in all but one level of the Yo-Yo Level 1 for CHO in comparison with other groups. Carbohydrate and caffeine mouth rinsing seems to exert no impact on running performance before maximal intermittent running in a group of male collegiate lacrosse players.

  19. Comparison between self-formulation and compounded-formulation dexamethasone mouth rinse for oral lichen planus: a pilot, randomized, cross-over trial.

    Science.gov (United States)

    Hambly, Jessica L; Haywood, Alison; Hattingh, Laetitia; Nair, Raj G

    2017-08-01

    There is a lack of appropriate, commercially-available topical corticosteroid formulations for use in oral lichen planus (OLP) and oral lichenoid reaction. Current therapy includes crushing a dexamethasone tablet and mixing it with water for use as a mouth rinse. This formulation is unpleasant esthetically and to use in the mouth, as it is a bitter and gritty suspension, resulting in poor compliance. Thus, the present study was designed to formulate and pilot an effective, esthetically-pleasing formulation. A single-blinded, cross-over trial was designed with two treatment arms. Patients were monitored for 7 weeks. Quantitative and qualitative data was assessed using VAS, numeric pain scales, the Treatment Satisfaction Questionnaire for Medication-9, and thematic analysis to determine primary patient-reported outcomes, including satisfaction, compliance, quality of life, and symptom relief. Nine patients completed the pilot trial. Data analysis revealed the new compounded formulation to be superior to existing therapy due to its convenience, positive contribution to compliance, patient-perceived faster onset of action, and improved symptom relief. Topical dexamethasone is useful in the treatment of OLP. When carefully formulated into a compounded mouth rinse, it improves patient outcomes. © 2016 John Wiley & Sons Australia, Ltd.

  20. MHD unsteady GO-water-squeezing nanofluid flow-heat and mass transfer between two infinite parallel moving plates: analytical investigation

    International Nuclear Information System (INIS)

    Azimi, Mohammadreza

    2017-01-01

    Investigation for unsteady squeezing viscous flow is one of the most important research topics due to its wide range of engineering applications such as polymer processing and lubrication systems. The aim of the present paper is to study the unsteady squeezing viscous graphene oxide-water nanofluid flow with heat transfer between two infinite parallel plates. The governing equations, continuity, momentum and energy for this problem are reduced to coupled nonlinear ordinary differential equations using a similarity transformation. The transmuted model is shown to be controlled by a number of thermo-physical parameters, viz., moving parameter, graphene oxide nanoparticles solid volume fraction, Eckert and Prandtl numbers. Nusselt number and skin friction parameter are obtained for various values of GO solid volume fraction and Eckert number. Comparison between analytical results and numerical ones achieved by fourth order Runge-Kutta method revealed that our analytical method can be a simple, powerful and efficient technique for finding analytical solutions in science and engineering nonlinear differential equations. (author)

  1. Resin-dentin Bond Stability of Experimental 4-META-based Etch-and-rinse Adhesives Solvated by Ethanol or Acetone.

    Science.gov (United States)

    Amaral, Cristiane Mariote; Diniz, Alice Marques; Arantes, Eugênio Braz Rodrigues; Dos Santos, Glauco Botelho; Noronha-Filho, Jaime Dutra; da Silva, Eduardo Moreira

    To investigate the influence of 4-META concentration and type of solvent on the degree of conversion (DC%) and resin-dentin bond stability of experimental etch-and-rinse adhesives. Four different concentrations of 4-META (12 wt%, 20 wt%, 30 wt%, 40 wt%) were added to a model adhesive system consisting of TEG-DMA (25 wt%), UDMA (20 wt%), HEMA (30 wt%), water (4 wt%), camphorquinone (0.5 wt%), and tertiary amine (0.5 wt%) dissolved in 20% acetone (A12, A20, A30 and A40) or 20% ethanol (E12, E20, E30 and E40). DC% was evaluated by FT-IR spectroscopy. Human molars were wet ground until the occlusal dentin was exposed, the adhesive systems were applied after 37% phosphoric acid etching, and resin composite buildups were incrementally constructed. After storage in distilled water at 37°C for 24 h, the teeth were cut into resin-dentin beams (cross-sectional area 1 mm2). Microtensile bond strength (μTBS) was evaluated after 24 h, 6 months, and 1 year of water storage at 37°C. The failure mode was categorized as adhesive, mixed, or cohesive. Data were analyzed using ANOVA and Tukey's HSD test (α = 0.05). A12 presented the lowest DC% (p 0.05). All adhesive systems maintained resin-dentin bond stability after 6 months of water storage, while only A40 and E40 maintained it after 1 year. Irrespective of the type of organic solvent, the incorporation of high concentrations of 4-META (40 wt%) improved the resin-dentin bond stability of the experimental etch-and-rinse adhesive systems over a period of 1 year.

  2. Chemometric analysis of the consumption of oral rinse chlorite (ClO2-) by human salivary biomolecules.

    Science.gov (United States)

    Chang, Hubert; Blackburn, John; Grootveld, Martin

    2013-12-01

    Oral rinse formulations containing chlorite anion (ClO(2)(-)) as an active agent exert a range of valuable oral healthcare activities. However, salivary biomolecules which chemically react with this oxidant can, at least in principle, serve as potentially significant barriers to these therapeutic properties in the oral environment. Therefore, in this investigation, we have explored the extent of ClO(2)(-) consumption by biomolecules which scavenge this agent in human salivary supernatants (HSSs) in vitro. HSS samples were equilibrated with oral rinse formulations containing this active agent (30 s at 35 °C in order to mimic oral rinsing episodes). Differential spectrophotometric and ion-pair reversed-phase high-performance liquid chromatographic analyses were employed to determine residual ClO(2)(-) in these admixtures. Bioanalytical data acquired revealed the rapid consumption of ClO(2)(-) by biomolecular electron donors and/or antioxidants present in HSS samples. Mean ± 95 % confidence interval (CI) consumption levels of 7.14 ± 0.69 and 5.34 ± 0.69 % of the total ClO(2)(-) available were found for oral rinse products containing 0.10 and 0.40 % (w/v) ClO(2)(-), respectively. A mixed model analysis-of-variance performed on experimental data acquired demonstrated highly-significant differences between oral rinse ClO(2)(-) contents (p biomolecules for both oral rinse formulations investigated. These observations are of much clinical significance in view of the retention of these products' active agent, i.e. biomolecules within recommended 30 s oral rinsing episodes, and hence, the bulk of this oxyhalogen oxidant (>90 %) may effectively exert its essential microbicidal, anti-periodontal and oral malodour-neutralising actions.

  3. The Effect of Calcium Pre-Rinse on Salivary Fluoride After 900 ppm Fluoride Mouthwash: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Nahid Ramazani

    2013-01-01

    Full Text Available Objective: Calcium fluoride deposit during fluoride application. Uptake and retention of fluoride by saliva depends generally on the concentration of calcium. In this study, the ef-fect of calcium pre-rinse on salivary fluoride concentration after a 900 ppm fluoride mouthwash was investigated.Materials and Methods: This cross-over double-blind randomized clinical trial was con-ducted in a girls' dormitory in Zahedan University of Medical Sciences, southeast Iran. In this study, 42 female dental students were chosen using simple randomization. During the first phase, 21 subjects (group A used fluoride rinse (F regimen and the remaining (group B used calcium pre-rinse followed immediately by fluoride rinse (Ca + F regi-men. In the second phase, participants rinsed using the mouthwashes not previously used. Prior to each phase prophylaxis was performed and no fluoridated product was used dur-ing a two-week interval between the phases. Salivary samples were taken immediately be-fore (baseline, 1 and 12 hours after rinsing. The salivary fluoride concentration was de-termined using fluoride sensitive electrode. Repeated measures ANOVA was used for sta-tistical analysis and the significance level was set at P<0.05.Results: There was significant difference between fluoride concentrations at different time points (P< 0.001. Significant differences were observed when the different time points of two regimens were examined. In contrast to this, the baseline before using F regimen and the baseline before using Ca + F regimen did not show any significance (P= 0.070.Conclusion: Pre-rinsing with calcium before fluoride is recommended because of signifi-cant increases in salivary fluoride concentration.

  4. Laser Induced Selective Activation For Subsequent Autocatalytic Electroless Plating

    DEFF Research Database (Denmark)

    Zhang, Yang

    . The third hypothesis is that the activation and rinsing process can be described by diffusion. This hypothesis is proved using Fick’s diffusion laws combined with the short-time-plating experiment. The influence of laser parameters on the surface structure is investigated for Nd:YAG, UV, and fiber lasers......The subject of this PhD thesis is “Laser induced selective activation for subsequent autocatalytic electroless plating.” The objective of the project is to investigate the process chains for micro structuring of polymer surfaces for selective micro metallization. Laser induced selective activation...... (LISA) is introduced and studied as a new technique for producing 3D moulded interconnect devices (3D-MIDs). This technique enables the metallization of polymer surface modified by laser and subsequently activated by a PdCl2/SnCl2 system. Various technologies exist on an industrial level...

  5. Chlorhexidine rinse for prevention of urethritis in men linked to oral sex

    Directory of Open Access Journals (Sweden)

    Kolahi Jafar

    2010-06-01

    Full Text Available Abstract Background Oral sex among teenagers is on the rise. Similarity between the oral flora and organisms recovered from nongonococcal urethritis and prostatitis, points to retrograde entry of bacteria from oral cavity into the urethra following insertive oral intercourse. Presentation of the hypothesis Chlorhexidine has a wide spectrum of anti-bactericidal activity encompassing gram positive and negative bacteria. It is also effective against HIV and HBV. It produced large and prolonged reductions in salivary bacterial counts within 7-h of its use. Hence, it would seem logic to postulate that rinsing with chlorhexidine before oral sex will be effective for prevention of retrograde entry of bacteria from oral cavity into the urethra. The recommendation for rinsing will be: 15 ml of a 0.12% or 10 ml of 0.2% chlorhexidine rinse for 30 seconds. Also other drug delivery systems such as chlorhexidine chewing gum or spray can be used. Testing the hypothesis Men suffering from recurrent nongonococcal urethritis or prostatitis are good subjects for testing the hypothesis. They perform genital safe sex via consistent use of condom. Yet they generally received unprotected insertive oral intercourse. Chlorhexidine can be used for prevention of recurrences of the disease. Implications of the hypothesis The chlorhexidine will be a new, easy, attractive and effective method for reduction of nongonococcal urethritis, prostatitis and epidydimitis following insertive oral intercourse. It is poorly absorbed from skin, mucosa and gastrointestinal tract indicating systemic safety of chlorhexidine. The agent does not cause any bacterial resistance and supra-infection.

  6. Treatment of oral malodor and periodontal disease using an antibiotic rinse.

    Science.gov (United States)

    Southward, Ken; Bosy, Anne

    2013-07-01

    The purpose of this study was to determine the effectiveness of an antibiotic rinse preparation, containing metronidazole and nystatin, in decreasing oral malodor and periodontal disease for individuals whose chief complaint was halitosis. This topical approach to oral biofilm control, by proactively managing the most pathogenic bacteria, differs from the traditional approach of reactively treating the symptoms by attempting to reduce all oral bacteria. The late Dr. Loesche, University of Michigan, School of Dentistry, had previously described these different paradigms as the specific plaque hypothesis and the non-specific plaque hypothesis, respectively. Patients in this study were measured before and after treatment for volatile sulphur compounds using a portable sulphide monitor, a digital gas chromatograph, and organoleptic assessment. The presence of periodontal disease was determined by 6-point periodontal probing, to assess pocket depth and bleeding points. Of the 1000 patient charts sent electronically to the University of Michigan for analysis, 649 participants were selected based on complete pre- and post-treatment data, and statistically analyzed by a statistician, who was an expert in case study analysis. The post-treatment reduction of oral malodor was 80% (P = 0.0001). The difference in bleeding points pre- and post-treatment was 87% (P = 0.0001). There was a decrease in the number of teeth with 6 and 7 mm pockets by 76% and teeth with 5 mm pockets decreased by 84% (P = 0.0001). Treatment with the antibiotic rinse had a positive change in the periodontal status and breath odor of these patients. These data indicate that there is considerable advantage to the use of topical antibiotic rinses. A substantial decrease in both halitosis and periodontal disease markers can be achieved without the risk of the systemic effects of an oral antibiotic.

  7. Non-rinse skin cleansers: the way forward in preventing incontinence related moisture lesions?

    Science.gov (United States)

    Harries, F J; Begg, P A

    2016-05-01

    The use of non-rinse skin cleansers in the care of patients who are at risk of tissue breakdown is not new within the National Health Service (NHS). Back to the Floor Continence Care Rounds (introduced in 2012 to facilitate bedside continence care education) at University Hospitals Birmingham had identified that in the current climate of austerity and efficiency savings, the use of non-rinse cleanser was being randomly rationed. Our objective was to determine whether the introduction of a smaller tube of non-rinse cleanser with targeted education would improve usage and ultimately improve the skin of incontinent patients. There were five clinical areas randomised into two groups. In group 1 three clinical areas were provided with targeted education and new sizes of tubes of non-rinse skin cleanser. In group 2, the two remaining clinical areas acted as control groups, one receiving targeted education only and the remaining had no education or new sized tubes. The incidence of incontinence associated moisture lesions from each clinical area was monitored for 13 weeks pre and post study period. The in-depth study undertaken at University Hospitals Birmingham, over a 6-month period, confirmed a trend in staff committing to the ethos of prudency, and in turn compromising the use of the most effective treatment and prevention of incontinence associated moisture lesions. The ability of the Trust staff to recognise and respond to a change in practice and the responsiveness of a commercial provider to the proposed new methodology has resulted in a significant reduction in incontinence associated moisture lesions across the trust. The clinical areas included in the study demonstrated a 70-76.9% reduction in moisture lesion incidence compared to an 8.3-13.6% reduction in the control groups. The results strongly suggest that a reduction in incontinence associated moisture lesions can be achieved by a simple change in nursing regime. The combination of solid education provision

  8. The effect of three whitening oral rinses on enamel micro-hardness

    OpenAIRE

    Potgieter, E; Osman, Y; Grobler, SR

    2014-01-01

    The purpose of this study was to determine the effect on human enamel micro-hardness of three over-the-counter whitening oral rinses available in South Africa. Enamel fragments were gathered into three groups of 15 each. One group was exposed to Colgate Plax Whitening Blancheur, the second group to White Glo 2 in 1 and the third to Plus White, in each case for periods recommended by the respective manufacturers. Surface micro-hardness of all groups was measured before and after a 14 day treat...

  9. Einfluss der Etch-and-Rinse-Technik auf Adper Easy Bond

    OpenAIRE

    Kunstmann, Thorsten

    2011-01-01

    Ziel der vorliegenden Studie war es die Auswirkungen der Etch-and-Rinse-Technik auf die Randqualität von Kompositfüllungen bei Anwendung des selbstätzenden Bondingsystems Adper Easy Bond zu untersuchen. An 64 extrahierten menschlichen Molaren wurden tiefe Klasse-II-Kavitäten präpariert, deren approximale Begrenzung unterhalb der Schmelz-Zement-Grenze lag. Diese wurden in acht Gruppen aufgeteilt, jeweils mit 8 Zähnen pro Gruppe, und mittels verschiedener Bonding-Techniken mit Kompositfüllungen...

  10. Site-specific mouth rinsing can improve oral odor by altering bacterial counts. Blind crossover clinical study.

    Science.gov (United States)

    Alqumber, Mohammed A; Arafa, Khaled A

    2014-11-01

    To determine whether site-specific mouth rinsing with oral disinfectants can improve oral odor beyond the traditional panoral mouth disinfection with mouth rinses by targeting specifically oral malodor implicated anaerobic bacteria. Twenty healthy fasting subjects volunteered for a blinded prospective, descriptive correlational crossover cross-section clinical trial conducted during the month of Ramadan between July and August 2013 in Albaha province in Saudi Arabia involving the application of Listerine Cool Mint mouth rinse by either the traditional panoral rinsing method, or a site-specific disinfection method targeting the subgingival and supragingival plaque and the posterior third of the tongue dorsum, while avoiding the remaining locations within the oral cavity. The viable anaerobic and aerobic bacterial counts, volatile sulfur compounds (VSCs) levels, organoleptic assessment of oral odor, and the tongue-coating index were compared at baseline, one, 5, and 9 hours after the treatment. The site-specific disinfection method reduced the VSCs and anaerobic bacterial loads while keeping the aerobic bacterial numbers higher than the traditional panoral rinsing method. Site-specific disinfection can more effectively maintain a healthy oral cavity by predominantly disinfecting the niches of anaerobic bacteria within the oral cavity.

  11. Composite Bipolar Plate for Unitized Fuel Cell/Electrolyzer Systems

    Science.gov (United States)

    Mittelsteadt, Cortney K.; Braff, William

    2009-01-01

    In a substantial improvement over present alkaline systems, an advanced hybrid bipolar plate for a unitized fuel cell/electrolyzer has been developed. This design, which operates on pure feed streams (H2/O2 and water, respectively) consists of a porous metallic foil filled with a polymer that has very high water transport properties. Combined with a second metallic plate, the pore-filled metallic plates form a bipolar plate with an empty cavity in the center.

  12. Effect of green tea extract on bonding durability of an etch-and-rinse adhesive system to caries-affected dentin

    Directory of Open Access Journals (Sweden)

    Carolina CARVALHO

    Full Text Available ABSTRACT Objective Green tea extract has been advocated as a matrix metalloproteinase (MMP inhibitor; however, its effect on bond durability to caries-affected dentin has never been reported. Thus, the aim of this in vitro study was to evaluate the effect of two MMP inhibitors (2% chlorhexidine and 2% green tea extract, applied after acid etching, on bond durability of an etch-and-rinse adhesive system to caries-affected dentin. Material and Methods Occlusal enamel was removed from third molars to expose the dentin surface, and the molars were submitted to a caries induction protocol for 15 days. After removal of infected dentin, specimens were conditioned with 37% phosphoric acid (15 seconds and randomly divided into three groups, according to the type of dentin pretreatment (n=10: NT: no treatment; GT: 2% green tea extract; CLX: 2% chlorhexidine. The etch-and-rinse adhesive system (Adper™ Single Bond 2, 3M ESPE, St. Paul, MN, USA was applied according to the manufacturer's instructions, and composite resin restorations were built on the dentin. After 24 hours, at 37°C, the resin-tooth blocks were sectioned perpendicularly to the adhesive interface in the form of sticks (0.8 mm2 of adhesive area and randomly subdivided into two groups according to when they were to be submitted to microtensile bond strength (μTBS testing: immediately or 6 months after storage in distilled water. Data were reported in MPa and submitted to two-way ANOVA for completely randomized blocks, followed by Tukey’s test (α=0.05. Results After 24 hours, there was no significant difference in the μTBS of the groups. After 6 months, the GT group had significantly higher μTBS values. Conclusion It was concluded that the application of 2% green tea extract was able to increase bond durability of the etch-and-rinse system to dentin. Neither the application of chlorhexidine nor non-treatment (NT - control had any effect on bond strength after water storage.

  13. Green remediation: enhanced reductive dechlorination using recycled rinse water as bioremediation substrate

    International Nuclear Information System (INIS)

    Dawson, Gaynor; McKeon, Tom

    2007-01-01

    Enhanced reductive dechlorination (ERD) has rapidly become a remedy of choice for use on chlorinated solvent contamination when site conditions allow. With this approach, solutions of an organic substrate are injected into the affected aquifer to stimulate biological growth and the resultant production of reducing conditions in the target zone. Under the reducing conditions, hydrogen is produced and ultimately replaces chlorine atoms on the contaminant molecule causing sequential dechlorination. Under suitable conditions the process continues until the parent hydrocarbon precursor is produced, such as the complete dechlorination of trichloroethylene (TCE) to ethene. The process is optimized by use of a substrate that maximizes hydrogen production per unit cost. When natural biota are not present to promote the desired degradation, inoculates can be added with the substrate. The in-situ method both reduces cost and accelerates cleanup. Successful applications have been extended from the most common chlorinated compounds perchloroethylene (PCE) and TCE and related products of degradation, to perchlorate, and even explosives such as RDX and trinitrotoluene on which nitrates are attacked in lieu of chloride. In recent work, the process has been further improved through use of beverage industry wastewaters that are available at little or no cost. With material cost removed from the equation, applications can maximize the substrate loading without significantly increasing total cost. The extra substrate loading both accelerates reaction rates and extends the period of time over which reducing conditions are maintained. In some cases, the presence of other organic matter in addition to simple sugars provides for longer performance times of individual injections, thereby working in a fashion similar to emulsified vegetable oil. The paper discusses results of applications at three different sites contaminated with chlorinated ethylenes. The applications have included wastewaters of both natural fruit juices and corn syrup solutions from carbonated beverages. Cost implications include both the reduced cost of substrate and the cost avoidance of needing to pay for treatment of the wastewater. (authors)

  14. (Pyridoxylated hemoglobin)-(polyoxyethylene) conjugate solution as blood substitute for normothermic whole body rinse-out.

    Science.gov (United States)

    Agishi, T; Funakoshi, Y; Honda, H; Yamagata, K; Kobayashi, M; Takahashi, M

    1988-01-01

    In order to investigate a new possibility for artificial blood with oxygen-carrying capability to be applied to other than mere supplementation, normothermic whole body rinse-out in which artificial blood deriving from perfluorochemical emulsion, Fluosol-DA 20% (Green Cross Co., Ltd., Osaka, Japan) or stabilized hemoglobin solution, (pyridoxylated hemoglobin)-(polyoxyethylene) conjugate solution (Ajinomoto Co., Ltd., Tokyo, Japan) were used as rinsing fluid for a blood purification experiment. Replacement either with approximately 150 ml/kg of Fluosol-DA or stabilized hemoglobin solution showed effective removal of digoxin at a reduction rate of 96.3% or 92.2%, respectively. However, when Fluosol-DA was used, a certain amount of perfluorochemical should be retrieved by centrifugation to avoid a possible toxic effect on the reticulo-endothelial system. Even though 3 out of 6, and 3 out of 8 dogs, respectively, survived for a long period after the procedure, the experimental dogs were very susceptible to infection.

  15. Effects of potassium oxalate on knoop hardness of etch-and-rinse adhesives.

    Science.gov (United States)

    Silva, S M A; Malacarne-Zanon, J; Carvalho, R M; Alves, M C; De Goes, M F; Anido-Anido, A; Carrilho, M R

    2012-01-01

    The objective of this study was to determine whether the hardness of etch-and-rinse adhesives may be affected by the pretreatment of acid-etched dentin with potassium oxalate desensitizer. Unerupted human third molars were cut into crown segments by removing the occlusal enamel and roots. The pulp chamber of these crown segments was connected to a syringe barrel filled with phosphate-buffered saline so that the moisture of dentin was maintained during the bonding procedures. Three etch-and-rinse adhesives-two two-step systems (Adper Single Bond 2 [SB], One-Step [OS]) and one three-step system (Adper Scotchbond Multi-Purpose [MP])-were applied to acid-etched dentin that had been treated (experimental groups) or not (control groups) with potassium oxalate (BisBlock). The Knoop hardness (KHN) of adhesives was taken at different sites of the outer surface of the adhesive-bonded dentin. The KHN of the three tested adhesives applied to acid-etched dentin treated with potassium oxalate was significantly lower than that exhibited by the respective controls (not treated with oxalate; padhesive, the treatment with potassium oxalate reduced the adhesives' KHN (psystem exhibiting the lowest KHN compared with the MP and SB systems.

  16. Impact of rinsing in pesticide packaging waste management: Economic and environmental benefits

    Directory of Open Access Journals (Sweden)

    Marčeta Una

    2015-01-01

    Full Text Available Pesticides have become dailiness due to inevitable application of these preparations in agricultural activities, with the consequence of generation of large amounts of waste packaging. Impact on the environment and expenses of management of packaging waste can be minimized if the packaging is immediately rinsed after the application of devices and if identified as non-hazardous. Besides, financial losses may be reduced by maximum utilization of the preparation. Considering these two financial aspects this work shows evaluation of quantitative losses of preparations if the triple rising method is not applied. The research was conducted in two phases. Phase I included the examination of the impact of different formulations of the same volume on quantitative and financial losses. Based on the results of the first phase of the research, it was noted that the SC formulation is the most interesting to study because this type of formulation has the highest percentage of residue, as well as the fact that the highest annual consumption is noted percisely in this preparation group. This paper presents the results which indicate the impact of packaging volume of SC formulation (ALVERDE 240 SC, INTERMEZZO and ANTRE PLUS on percentage of preparation residue in packaging if there was no rinsing. The results have shown that the quantitative loss is inversely proportional to the volume of packaging, while financial losses do not only depend on the percentage of residue but also on price and quantity of utilization of preparations.

  17. Study of residue type defect formation mechanism and the effect of advanced defect reduction (ADR) rinse process

    Science.gov (United States)

    Arima, Hiroshi; Yoshida, Yuichi; Yoshihara, Kosuke; Shibata, Tsuyoshi; Kushida, Yuki; Nakagawa, Hiroki; Nishimura, Yukio; Yamaguchi, Yoshikazu

    2009-03-01

    Residue type defect is one of yield detractors in lithography process. It is known that occurrence of the residue type defect is dependent on resist development process and the defect is reduced by optimized rinsing condition. However, the defect formation is affected by resist materials and substrate conditions. Therefore, it is necessary to optimize the development process condition by each mask level. Those optimization steps require a large amount of time and effort. The formation mechanism is investigated from viewpoint of both material and process. The defect formation is affected by resist material types, substrate condition and development process condition (D.I.W. rinse step). Optimized resist formulation and new rinse technology significantly reduce the residue type defect.

  18. Radiation shielding plate

    International Nuclear Information System (INIS)

    Kobayashi, Torakichi; Sugawara, Takeo.

    1983-01-01

    Purpose: To reduce the weight and stabilize the configuration of a radiation shielding plate which is used in close contact with an object to be irradiated with radiation rays. Constitution: The radiation shielding plate comprises a substrate made of lead glass and a metallic lead coating on the surface of the substrate by means of plating, vapor deposition or the like. Apertures for permeating radiation rays are formed to the radiation shielding plate. Since the shielding plate is based on a lead glass plate, a sufficient mechanical strength can be obtained with a thinner structure as compared with the conventional plate made of metallic lead. Accordingly, if the shielding plate is disposed on a soft object to be irradiated with radiation rays, the object and the plate itself less deform to obtain a radiation irradiation pattern with distinct edges. (Moriyama, K.)

  19. The effect of carbohydrate mouth rinse on performance, biochemical and psychophysiological variables during a cycling time trial: a crossover randomized trial.

    Science.gov (United States)

    Ferreira, Amanda M J; Farias-Junior, Luiz F; Mota, Thaynan A A; Elsangedy, Hassan M; Marcadenti, Aline; Lemos, Telma M A M; Okano, Alexandre H; Fayh, Ana P T

    2018-01-01

    The hypothesis of the central effect of carbohydrate mouth rinse (CMR) on performance improvement in a fed state has not been established, and its psychophysiological responses have not yet been described. The aim of this study was to evaluate the effect of CMR in athletes fed state on performance, biochemical and psychophysiological responses compared to ad libitum water intake. Eleven trained male cyclists completed a randomized, crossover trial, which consisted of a 30 km cycle ergometer at self-selected intensity and in a fed state. Subjects were under random influence of the following interventions: CMR with a 6% unflavored maltodextrin solution; mouth rinsing with a placebo solution (PMR); drinking "ad libitum" (DAL). The time for completion of the test (min), heart rate (bpm) and power (watts), rating of perceived exertion (RPE), affective response, blood glucose (mg/dL) and lactate (mmol/DL), were evaluated before, during and immediately after the test, while insulin (uIL/mL), cortisol (μg/dL) and creatine kinase (U/L) levels were measured before, immediately after the test and 30 min after the test. Time for completion of the 30 km trial did not differ significantly among CMR, PMR and DAL interventions (means = 54.5 ± 2.9, 54.7 ± 2.9 and 54.5 ± 2.5 min, respectively; p  = 0.82). RPE and affective response were higher in DAL intervention ( p  creatine kinase responses showed no significant difference among interventions. In a fed state, CMR has not caused metabolic changes, and it has not improved physical performance compared to ad libitum water intake, but demonstrated a possible central effect. ReBec registration number: RBR-4vpwkg. Available in http://www.ensaiosclinicos.gov.br/rg/?q=RBR-4vpwkg.

  20. Fuel cell cooler-humidifier plate

    Science.gov (United States)

    Vitale, Nicholas G.; Jones, Daniel O.

    2000-01-01

    A cooler-humidifier plate for use in a proton exchange membrane (PEM) fuel cell stack assembly is provided. The cooler-humidifier plate combines functions of cooling and humidification within the fuel cell stack assembly, thereby providing a more compact structure, simpler manifolding, and reduced reject heat from the fuel cell. Coolant on the cooler side of the plate removes heat generated within the fuel cell assembly. Heat is also removed by the humidifier side of the plate for use in evaporating the humidification water. On the humidifier side of the plate, evaporating water humidifies reactant gas flowing over a moistened wick. After exiting the humidifier side of the plate, humidified reactant gas provides needed moisture to the proton exchange membranes used in the fuel cell stack assembly. The invention also provides a fuel cell plate that maximizes structural support within the fuel cell by ensuring that the ribs that form the boundaries of channels on one side of the plate have ends at locations that substantially correspond to the locations of ribs on the opposite side of the plate.

  1. Impact of carbohydrate mouth rinsing on time to exhaustion during Ramadan: A randomized controlled trial in Jordanian men.

    Science.gov (United States)

    Bataineh, Mo'ath F; Al-Nawaiseh, Ali M; Abu Altaieb, Mohammad H; Bellar, David M; Hindawi, Omar S; Judge, Lawrence W

    2018-04-01

    Mouth rinsing using a carbohydrate (CHO) solution has been suggested to improve physical performance in fasting participants. This study examined the effects of CHO mouth rinsing during Ramadan fasting on running time to exhaustion and on peak treadmill speed (V peak ). In a counterbalanced crossover design, 18 sub-elite male runners (Age: 21 ± 2 years, Weight: 68.1 ± 5.7 kg, VO 2max : 55.4 ± 4.8 ml/kg/min) who observed Ramadan completed a familiarization trial and three experimental trials. The three trials included rinsing and expectorating a 25 mL bolus of either a 7.5% sucrose solution (CHO), a flavour and taste matched placebo solution (PLA) for 10 s, or no rinse (CON). The treatments were performed prior to an incremental treadmill test to exhaustion. Three-day dietary and exercise records were obtained on two occasions and analysed. Anthropometric characteristics were obtained and recorded for all participants. A main effect for mouth rinse on peak velocity (V peak ) (CHO: 17.6 ± 1.5 km/h; PLA: 17.1 ± 1.4 km/h; CON: 16.7 ± 1.2 km/h; P  .05). Energy availability from dietary analysis, body weight, and fat-free mass did not change during the last two weeks of Ramadan (P > .05). This study concludes that carbohydrate mouth rinsing improves running time to exhaustion and peak treadmill speed under Ramadan fasting conditions.

  2. Clinical and Microbial Evaluation of the Effects on Gingivitis of a Mouth Rinse Containing an Enteromorpha linza Extract

    Science.gov (United States)

    Cho, Han-Bin; Lee, Hee-Hyun; Lee, Ok-Hwan; Choi, Hyeon-Son; Choi, Jae-Suk

    2011-01-01

    Abstract Enteromorpha linza, a green alga, has been recognized as a potential source of natural antimicrobial and antifungal compounds. We previously reported that an E. linza extract strongly inhibited the growth of Prevotella intermedia and Porphyromonas gingivalis. The principal objective of this study was to evaluate the clinical effect of a mouth rinse containing the E. linza extract on gingivitis disease, as measured by the plaque index (PI), gingival index (GI), and bleeding on probing (BOP), and on two bacterial strains (P. intermedia and P. gingivalis), in comparison with Listerine® (Listerine-Korea, Seoul, Korea), which was used as a positive control. In total, 55 subjects were recruited into active participation in this clinical study. The PI, GI, BOP, and bacterial strains were then evaluated over a test period of 6 weeks. After 1, 2, 4, and 6 weeks, the same clinical indices were recorded, and the levels of P. intermedia and P. gingivalis were quantified via real-time polymerase chain reaction. At the end of the study, the group using the mouth rinse containing the E. linza extract evidenced significant reductions in the clinical indices (PI, GI, and BOP) and P. gingivalis compared with baseline values. Moreover, E. linza extract containing mouth rinse produced effects similar to those of Listerine. Overall, these results indicate that a mouth rinse containing E. linza extract significantly reduces plaque, improves the condition of gingival tissues, and reduces bleeding. Additionally, E. linza extract mouth rinse significantly inhibits P. gingivalis and P. intermedia. Thus, this clinical study demonstrated that the twice-daily use of an E. linza extract mouth rinse can inhibit and prevent gingivitis. PMID:22145775

  3. Effect of Peracetic Acid as A Final Rinse on Push Out Bond Strength of Root Canal Sealers to Root Dentin.

    Science.gov (United States)

    Gaddala, Naresh; Veeramachineni, Chandrasekhar; Tummala, Muralidhar

    2015-05-01

    Smear layer which was formed during the instrumentation of root canals hinders the penetration of root canal sealers to root dentin and affect the bond strength of root canal sealers to root dentin. Final irrigant such as demineralizing agents are used to remove the inorganic portion of the smear layer. In the present study, peracetic acid used as a final rinse, to effect the bond strength of root canal sealers to root dentin. The purpose of the present study was to evaluate the efficacy of peracetic acid as a final irrigant on bond strength of root canal sealers to root dentin. Sixty six freshly extracted human single rooted mandibular premolars were used for this study. After decoronation the samples were instrumented with Protaper upto F3 and irrigated with 5.25% NaOcl. The teeth were then divided into three groups based on final irrigant used: Group-1(control group) Canals were irrigated with distilled water. Group-2: Canals were irrigated with peracetic acid. Group-3: Canals were irrigated with smear clear. Each group was further divided into three subgroups (n=30) based on the sealer used to obturate the canals. Subgroup-1: kerr, Subgroup-2: Apexit plus, Subgroup-3: AH PLUS. Each sealer was mixed and coated to master cone and placed in the canal. The bonding between sealer and dentin surface was evaluated using push out bond strength by universal testing machine. The mean bond strength values of each group were statistically evaluated using Two-way ANOVA followed by Tukey post-hoc test. Significant difference was found among the bond strength of the sealers. But, there is no statistically significant difference between the groups irrigated with peracetic acid and smear clear compared to control group. AH Plus showed highest bond strength irrespective of the final irrigant used. Peracetic acid when employed as final irrigant improved the bond strength of root canal sealers compared to control group but not statistically significant than smear clear.

  4. Mechanical and microbiological properties and drug release modeling of an etch-and-rinse adhesive containing copper nanoparticles.

    Science.gov (United States)

    Gutiérrez, M F; Malaquias, P; Matos, T P; Szesz, A; Souza, S; Bermudez, J; Reis, A; Loguercio, A D; Farago, P V

    2017-03-01

    To evaluate the effect of addition of copper nanoparticles (CN) at different concentrations into a two-step etch-and-rinse (2-ER) adhesive on antimicrobial activity (AMA), copper release (CR), ultimate tensile strength (UTS), degree of conversion (DC), water sorption (WS), solubility (SO), as well as the immediate (IM) and 1-year resin-dentin bond strength (μTBS) and nanoleakage (NL). Seven adhesives were formulated according to the addition of CN (0, 0.0075, 0.015, 0.06, 0.1, 0.5 and 1wt%) in adhesive. The AMA was evaluated against Streptococcus mutans using agar diffusion assay. For CR, WS and SO, specimens were constructed and tested for 28 days. For UTS, specimens were tested after 24h and 28 days. For DC, specimens were constructed and tested after 24h by FTIR. After enamel removal, the ER was applied to dentin. After composite resin build-ups, specimens were sectioned to obtain resin-dentin sticks. For μTBS and NL, specimens were tested after 24h and 1-year periods. All data were submitted to statistical analysis (α=0.05). The addition of CN provided AMA to the adhesives at all concentrations. Higher CR was observed in adhesives with higher concentration of CN. UTS, DC, WS and SO were not influenced. For μTBS an increase was observed in 0.1 and 0.5% copper group. For NL, a significant decrease was observed in all groups in comparison with control group. After 1-year, no significant reductions of μTBS and no significant increases of NL were observed for copper containing adhesives compared to the control group. The addition of CN in concentrations up to 1wt% in the 2-ER adhesive may be an alternative to provide AMA and preserve the bonding to dentin, without reducing adhesives' mechanical properties evaluated. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  5. Shear bond strength of two 2-step etch-and-rinse adhesives when bonding ceramic brackets to bovine enamel.

    Science.gov (United States)

    Godard, Marion; Deuve, Benjamin; Lopez, Isabelle; Hippolyte, Marie-Pascale; Barthélemi, Stéphane

    2017-09-01

    The present study assessed a fracture analysis and compared the shear bond strength (SBS) of two 2-step etch-and-rinse (E&R) adhesives when bonding ceramic orthodontic brackets to bovine enamel. Thirty healthy bovine mandibular incisors were selected and were equally and randomly assigned to 2 experimental groups. Ceramic brackets (FLI Signature Clear ® , RMO) were bonded onto bovine enamel using an adhesive system. In group 1 (n=15), the conventional E&R adhesive (OrthoSolo ® +Enlight ® , Ormco) was used, and in group 2 (n=15), the new E&R adhesive limited to ceramic bracket bonding (FLI ceramic adhesive ® : FLI sealant resin ® +FLI adhesive paste ® , RMO) was used. In order to obtain appropriate enamel surfaces, the vestibular surfaces of mandibular bovine incisors were flat ground. After bonding, all the samples were stored in distilled water at room temperature for 21 days and subsequently tested for SBS, using the Instron ® universal testing machine. The Adhesive Remnant Index (ARI) scores were evaluated. Failure modes were assessed using optical microscopy at magnification ×40. A statistic data analysis was performed using the Mann-Whitney U-test (Penamel/adhesive interface. A statistically significant difference was found for the ARI scores between the two groups (P=0.00996). Only two fractured brackets, which remained bonded onto the bovine enamel, were reported. Both occurred in group 1. When bonded to ceramic brackets, FLI ceramic adhesive ® (RMO) was demonstrated to be very predictable and safe for clinical application in enamel bonding, whereas the results obtained with the conventional adhesive system (OrthoSolo ® +Enlight ® , Ormco) were less reproducible and revealed slightly excessive shear bond strength values. Copyright © 2017 CEO. Published by Elsevier Masson SAS. All rights reserved.

  6. Create Your Plate

    Medline Plus

    Full Text Available ... foods you want, but changes the portion sizes so you are getting larger portions of non-starchy ... plate. Then on one side, cut it again so you will have three sections on your plate. ...

  7. Create Your Plate

    Medline Plus

    Full Text Available ... of the differences in types of vegetables. When creating your plate at home, remember that half of ... effective for both managing diabetes and losing weight. Creating your plate lets you still choose the foods ...

  8. Create Your Plate

    Medline Plus

    Full Text Available ... Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type 1 Diabetes Get Started Safely Get And ... Plate Create Your Plate is a simple and effective way to manage your blood glucose levels and ...

  9. Create Your Plate

    Medline Plus

    Full Text Available ... Meals Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with ... Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart-Healthy ...

  10. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal ... Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook ...

  11. A prospective, randomized placebo-controlled clinical trial on the effects of a fluoride rinse on white spot lesion development and bleeding in orthodontic patients

    NARCIS (Netherlands)

    van der Kaaij, N.C.W.; van der Veen, M.H.; van der Kaaij, M.A.E.; ten Cate, J.M.

    2015-01-01

    Demineralizations around orthodontic brackets are a main disadvantage of orthodontic treatment. Several methods have been advocated to prevent their development, such as fluoride rinses or varnishes. In this randomized clinical trial, a fluoride rinse (a combination of sodium fluoride and amine

  12. Corrosion behavior of ion implanted nickel-titanium orthodontic wire in fluoride mouth rinse solutions.

    Science.gov (United States)

    Iijima, Masahiro; Yuasa, Toshihiro; Endo, Kazuhiko; Muguruma, Takeshi; Ohno, Hiroki; Mizoguchi, Itaru

    2010-01-01

    This study investigated the corrosion properties of ion implanted nickel-titanium wire (Neo Sentalloy Ionguard) in artificial saliva and fluoride mouth rinse solutions (Butler F Mouthrinse, Ora-Bliss). Non ion implanted nickel-titanium wire (Neo Sentalloy) was used as control. The anodic corrosion behavior was examined by potentiodynamic polarization measurement. The surfaces of the specimens were examined with SEM. The elemental depth profiles were characterized by XPS. Neo Sentalloy Ionguard in artificial saliva and Butler F Mouthrinse (500 ppm) had a lower current density than Neo Sentalloy. In addition, breakdown potential of Neo Sentalloy Ionguard in Ora-Bliss (900 ppm) was much higher than that of Neo Sentalloy although both wires had similar corrosion potential in Ora-Bliss (450 and 900 ppm). The XPS results for Neo Sentalloy Ionguard suggested that the layers consisted of TiO(2) and TiN were present on the surface and the layers may improve the corrosion properties.

  13. Effect of caries-affected dentin on one-step universal and multi-step etch-and-rinse adhesives’ bond strength

    Directory of Open Access Journals (Sweden)

    Clecila MÜLLER

    2017-10-01

    Full Text Available Abstract Objective To evaluate the influence of caries-affected dentin on bond strength of a universal one-step and a multi-step etch-and-rinse adhesive system. Material and method Enamel of 60 third human molars with and without caries was removed to expose dentin. The teeth were randomly assigned to six groups: Single Bond Universal (3M ESPE, St. Paul, MN, USA in etch-and-rinse and in self-etch mode and Prime & Bond NT (Dentsply Co, Konstanz, Germany, all on sound and caries-affected dentin. Smear layer of the 30 sound dentin specimens was standardized by polishing with 600-grit SiC paper under water cooling. Residual infected dentin of the 30 caries-affected specimens was removed with a number 4 CA carbide bur until no caries smooth tissue was detectable by tactile-visual inspection. Cylinders of a light cured composite resin (Filtek Z350 XT, 3M ESPE were built up using starch tubes and microshear test was performed until failure. The data was analyzed by one-way ANOVA and Tukey’s post hoc test. Result Significant differences in microshear bond strength (μSBS were observed for the caries-affected groups, but not for sound dentin. The μSBS of Single Bond Universal were not influenced by the application protocol on sound dentin, however they were lower in the caries-affected group with both application protocols. The μSBS for Prime & Bond NT was not influenced by the dentin conditions. Conclusion Caries-affected dentin decrease in bond strength of Single Bond Universal in comparison to sound dentin. The bond strength of Prime & Bond NT was not altered by substrate conditions.

  14. Creep analysis of fuel plates for the Advanced Neutron Source

    International Nuclear Information System (INIS)

    Swinson, W.F.; Yahr, G.T.

    1994-11-01

    The reactor for the planned Advanced Neutron Source will use closely spaced arrays of fuel plates. The plates are thin and will have a core containing enriched uranium silicide fuel clad in aluminum. The heat load caused by the nuclear reactions within the fuel plates will be removed by flowing high-velocity heavy water through narrow channels between the plates. However, the plates will still be at elevated temperatures while in service, and the potential for excessive plate deformation because of creep must be considered. An analysis to include creep for deformation and stresses because of temperature over a given time span has been performed and is reported herein

  15. Comparison of antimicrobial efficacy of chlorhexidine and combination mouth rinse in reducing the Mutans streptococcus count in plaque

    Directory of Open Access Journals (Sweden)

    Laxmi S Lakade

    2014-01-01

    Full Text Available Background: The removal of plaque is utmost important to control dental caries. But in children, factors like lack of dexterity, individual motivation and monitoring limit the effectiveness of tooth brushing. This necessitates the use of chemotherapeutic agents for control of plaque. Aims: To compare the antimicrobial efficacy of 0.2% chlorhexidine mouth rinse and mouth rinse containing 0.03% triclosan, 0.05% sodium fluoride, and 5% xylitol in reducing the Mutans streptococcus count in plaque. Materials and Methods: Thirty healthy children aged 8-10 years with dmft (decay component of three or four were selected. They were divided randomly into two groups: The control or chlorhexidine group and the study group or combination mouth rinse. Both the groups practiced rinsing with respective mouth wash for 1 min for 15 d twice a day. The plaque samples were collected and after incubation Mutans streptococcus count was estimated on the strips from the Dentocult SM kit and evaluated using manufacture′s chart. Statistical Analysis Used: Wilcoxon matched pairs signed ranks test and Mann-Whitney U test were used to analyze the findings. Results: Statistically significant reduction in the Mutans streptococci count in the plaque was seen in the control and study group from baseline level. But when both the groups were compared, the antimicrobial effect of chlorhexidine was more.

  16. Chromic acid recovery by electro-electrodialysis. II. Pilot scal process, development, and optimization

    NARCIS (Netherlands)

    Frenzel, I.; Frenzel, I.; Holdik, H.; Stamatialis, Dimitrios; Pourcelly, G.; Wessling, Matthias

    2005-01-01

    Electro-electrodialysis is a promising technology for chromic acid recovery and static rinse water purification. It combines the recovery of the plating chemicals from rinse water, the elimination of metallic impurities from the process and rinse water treatment in one step. Previous industrial use

  17. Paper microzone plates.

    Science.gov (United States)

    Carrilho, Emanuel; Phillips, Scott T; Vella, Sarah J; Martinez, Andres W; Whitesides, George M

    2009-08-01

    This paper describes 96- and 384-microzone plates fabricated in paper as alternatives to conventional multiwell plates fabricated in molded polymers. Paper-based plates are functionally related to plastic well plates, but they offer new capabilities. For example, paper-microzone plates are thin (approximately 180 microm), require small volumes of sample (5 microL per zone), and can be manufactured from inexpensive materials ($0.05 per plate). The paper-based plates are fabricated by patterning sheets of paper, using photolithography, into hydrophilic zones surrounded by hydrophobic polymeric barriers. This photolithography used an inexpensive formulation photoresist that allows rapid (approximately 15 min) prototyping of paper-based plates. These plates are compatible with conventional microplate readers for quantitative absorbance and fluorescence measurements. The limit of detection per zone loaded for fluorescence was 125 fmol for fluorescein isothiocyanate-labeled bovine serum albumin, and this level corresponds to 0.02 the quantity of analyte per well used to achieve comparable signal-to-noise in a 96-well plastic plate (using a solution of 25 nM labeled protein). The limits of detection for absorbance on paper was approximately 50 pmol per zone for both Coomassie Brilliant Blue and Amaranth dyes; these values were 0.4 that required for the plastic plate. Demonstration of quantitative colorimetric correlations using a scanner or camera to image the zones and to measure the intensity of color, makes it possible to conduct assays without a microplate reader.

  18. Reliable solution processed planar perovskite hybrid solar cells with large-area uniformity by chloroform soaking and spin rinsing induced surface precipitation

    Directory of Open Access Journals (Sweden)

    Yann-Cherng Chern

    2015-08-01

    Full Text Available A solvent soaking and rinsing method, in which the solvent was allowed to soak all over the surface followed by a spinning for solvent draining, was found to produce perovskite layers with high uniformity on a centimeter scale and with much improved reliability. Besides the enhanced crystallinity and surface morphology due to the rinsing induced surface precipitation that constrains the grain growth underneath in the precursor films, large-area uniformity with film thickness determined exclusively by the rotational speed of rinsing spinning for solvent draining was observed. With chloroform as rinsing solvent, highly uniform and mirror-like perovskite layers of area as large as 8 cm × 8 cm were produced and highly uniform planar perovskite solar cells with power conversion efficiency of 10.6 ± 0.2% as well as much prolonged lifetime were obtained. The high uniformity and reliability observed with this solvent soaking and rinsing method were ascribed to the low viscosity of chloroform as well as its feasibility of mixing with the solvent used in the precursor solution. Moreover, since the surface precipitation forms before the solvent draining, this solvent soaking and rinsing method may be adapted to spinless process and be compatible with large-area and continuous production. With the large-area uniformity and reliability for the resultant perovskite layers, this chloroform soaking and rinsing approach may thus be promising for the mass production and commercialization of large-area perovskite solar cells.

  19. Negligible penetration of incidental amounts of alpha-hydroxy acid from rinse-off personal care products in human skin using an in vitro static diffusion cell model.

    Science.gov (United States)

    Okuda, M; Donahue, D A; Kaufman, L E; Avalos, J; Simion, F A; Story, D C; Sakaguchi, H; Fautz, R; Fuchs, A

    2011-12-01

    Alpha-hydroxy acids (AHAs), primarily glycolic and lactic acids, are widely used in cosmetics to alleviate dyspigmentation, photodamage, and other aging skin conditions and as pH adjusters. Glycolic acid reportedly enhances skin damage after repeated ultraviolet light exposure, e.g., increased sunburn cell formation. This study assessed potential in vitro skin penetration of lactic acid and malic acid incorporated into rinse-off personal care products, compared with rinse-off and leave-on exposures to glycolic acid (10%, pH 3.5) in a reference lotion. Radiolabeled AHA-fortified shampoo, conditioner, and lotion were evenly applied as single doses to human epidermal membranes mounted in static diffusion cells (not occluded). Exposures were 1-3 min (rinse-off) or 24 h (leave-on). Epidermal penetration of malic acid and lactic acid from the rinse-off shampoo and conditioner, respectively, was negligible, with >99% removed by rinsing, a negligible portion remaining in the stratum corneum (≤0.15%), and even less penetrating into the viable epidermis (≤0.04%). Glycolic acid penetration from the leave-on reference lotion was 1.42 μg equiv./cm2/h, with total absorbable dose recovery (receptor fluid plus epidermis) of 2.51%, compared to 0.009%, 0.003%, and 0.04% for the rinse-off reference lotion, shampoo (malic acid), and conditioner (lactic acid) exposures, respectively. Dermal penetration of AHAs into human skin is pH-, concentration-, and time-dependent. Alpha-hydroxy acids in rinse-off shampoos and conditioners are almost entirely removed from the skin within minutes by rinsing (resulting in negligible epidermal penetration). This suggests that ultraviolet radiation-induced skin effects of AHA-containing rinse-off products are negligible. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. Alkali ocular burns in Martinique (French West Indies) Evaluation of the use of an amphoteric solution as the rinsing product.

    Science.gov (United States)

    Merle, Harold; Donnio, Angélique; Ayeboua, Lucas; Michel, Franck; Thomas, Félix; Ketterle, Jeannine; Leonard, Christian; Josset, Patrice; Gerard, Max

    2005-03-01

    During the 4 years of this study, we noted 66 cases of alkali ocular burns, or approximately 16 cases per year, nearly half (45.5%) of which are due to an assault. For grade 1 and 2 burns the time elapsed to reepithelialization appears to be shorter when rinsed with Diphoterine* versus physiological solution. Comparison of the effectiveness of two rinsing solutions for emergency use: a physiological solution and an amphoteric solution (Diphoterine*, Laboratories Prevor, Valmondois, France). Description of the clinical and progressive characteristics of alkali burns treated at the University Hospital Center of Fort de France in Martinique (French West Indies). Prospective consecutive observational case series and nonrandomized comparative study. Sixty-six patients were included. The total number of burned eyes is 104. Forty-eight eyes (46%) were rinsed with physiological solution and 56 eyes (54%) with Diphoterine*. All patients benefited from an ocular rinse with 500ml of physiological solution or Diphoterine*, followed by a complete ophthalmologic exam. The ocular injuries were classified according to the Roper-Hall modification of the Hughes classification system. The same standardized therapeutic protocol was applied and adapted to the seriousness of the burn. Demographic data, time to corneal reepithelialization, final best corrected visual acuity and complications were analysed. Twenty-eight (42.4%) patients have a unilateral burn and 38 (57.6%) patients have bilateral burns. In decreasing order of frequency, the circumstances surrounding the injury are: assaults in 45.5% of cases (n=30), work-related accidents in 32% of cases (n=31), and domestic accidents in 23% of cases (n=15). For grade 1 and 2 burns the time elapsed to reepithelialization appears to be shorter when rinsed with Diphoterine* versus physiological solution (respectively): 1.9+/-1 days versus 11.1+/-1.4 days (p=10(-7)) and 5.6+/-4.9 days versus 10+/-9.2 days (p=0.02). For grade 3 and 4 burns

  1. 不同漂洗方式对高白鲑肌肉蛋白劣变影响的研究%Study on the effect of different rinsing on muscle protein deterioration of coregonus peled

    Institute of Scientific and Technical Information of China (English)

    高泽磊; 刘彩华; 彭波; 朱新荣; 张建

    2017-01-01

    Using the H2O2/Asc oxidation system to simulate the vitro oxidation,through the detection of physicochemical indexes,to study the effect of coregonus peled muscle'deteriorating through using different rinsing methods.The results showed that both 0.3% PG and 0.5% saline water can prevent oxidation of the protein,but PG was better than saline water,although the sodium ascorbate was used as antioxygen,it has effects of promote oxidation.Single factor experiment and response surface analysis were used to study the rinsing process.It shows when the concentration of 0.21% PG,rinse times for twice,rinse time for 6 min.Under the condition,the protein oxidation inhibited rate was 30.12%.The above conditions could effectively prevent protein oxidation caused coregonus peled muscle and increased the quality of coregonus peled.%利用H2O2/Asc氧化系统模拟体外氧化,通过理化指标的检测,研究了不同漂洗方式对高白鲑肌肉蛋白劣变的影响.结果显示:浓度为0.3%没食子酸丙酯和0.5%盐水都具有防止蛋白质氧化的效果,但没食子酸丙酯的效果要优于盐水,而抗坏血酸钠虽然作为抗氧化剂,却有促进氧化的效果;通过单因素实验及响应面分析法对漂洗工艺进行了研究.结果表明,浓度为0.21% PG溶液、漂洗次数为2次、漂洗时间为6 min,此时蛋白质氧化抑制率为30.12%.结果说明,上述漂洗条件下能够有效防止高白鲑肌肉蛋白的劣变,增加高白鲑的品质.

  2. Create Your Plate

    Medline Plus

    Full Text Available ... Type 2 Diabetes Know Your Rights Employment Discrimination Health Care Professionals Law ... Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart- ...

  3. Create Your Plate

    Medline Plus

    Full Text Available ... Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday ... Carbohydrates Types of Carbohydrates Carbohydrate Counting Make Your Carbs ...

  4. Water purification using organic salts

    Science.gov (United States)

    Currier, Robert P.

    2004-11-23

    Water purification using organic salts. Feed water is mixed with at least one organic salt at a temperature sufficiently low to form organic salt hydrate crystals and brine. The crystals are separated from the brine, rinsed, and melted to form an aqueous solution of organic salt. Some of the water is removed from the aqueous organic salt solution. The purified water is collected, and the remaining more concentrated aqueous organic salt solution is reused.

  5. The baffle influence on sound radiation characteristics of a plate

    Directory of Open Access Journals (Sweden)

    Bao Liu

    2017-01-01

    Full Text Available The acoustic radiation characteristics of the baffle plates and unbaffle plates are calculated and compared by single-layer potential and double-layer potential. Based on the boundary integral equation, the sound pressure integral equation of the baffle and the baffle are deduced respectively. According to the boundary compatibility condition, the sound pressure and the vibration velocity of the plates are obtained. Further, the dynamic equation of the structure is substituted into the vibration equation in the form of the baffle plate and the baffle plate. The sound pressure difference and the displacement of a plate surface are in the form of the vibration mode superposition and the acoustic radiation impedance of the double integral form is obtained, which determines vibration mode coefficient and sound radiation parameters. The effect of the baffle on the acoustic radiation characteristics of the thin plate is analyzed by comparing the acoustic radiation parameters with the simple and simple rectangular plate in water.

  6. Electric alignment of plate shaped clay aggregates in oils

    Science.gov (United States)

    Castberg, Rene; Rozynek, Zbigniew; Måløy, Knut Jørgen; Flekkøy, Eirik

    2016-01-01

    We experimentally investigate the rotation of plate shaped aggregates of clay mineral particles immersed in silicone oil. The rotation is induced by an external electric field. The rotation time is measured as a function of the following parameters: electric field strength, the plate geometry (length and width) and the dielectric properties of the plates. We find that the plates always align with their longest axis parallel to the direction of the electric field (E), independently of the arrangement of individual clay -2 mineral particles within the plate. The rotation time is found to scale as E and is proportional to the viscosity (μ), which coincides well with a model that describes orientation of dipoles in electric fields. As the length of the plate is increased we quantify a difference between the longitudinal and transverse polarisability. Finally, we show that moist plates align faster. We attribute this to the change of the dielectric properties of the plate due to the presence of water.

  7. Cognitive Performance Enhancement Induced by Caffeine, Carbohydrate and Guarana Mouth Rinsing during Submaximal Exercise

    Directory of Open Access Journals (Sweden)

    Laura Pomportes

    2017-06-01

    Full Text Available The aim of this study was to investigate the influence of serial mouth rinsing (MR with nutritional supplements on cognitive performance (i.e., cognitive control and time perception during a 40-min submaximal exercise. Twenty-four participants completed 4 counterbalanced experimental sessions, during which they performed MR with either placebo (PL, carbohydrate (CHO: 1.6 g/25 mL, guarana complex (GUAc: 0.4 g/25 mL or caffeine (CAF: 67 mg/25 mL before and twice during exercise. The present study provided some important new insights regarding the specific changes in cognitive performance induced by nutritional supplements. The main results were: (1 CHO, CAF and GUA MR likely led participants to improve temporal performance; (2 CAF MR likely improved cognitive control; and (3 CHO MR led to a likely decrease in subjective perception of effort at the end of the exercise compared to PL, GUA and CAF. Moreover, results have shown that performing 40-min submaximal exercise enhances information processing in terms of both speed and accuracy, improves temporal performance and does not alter cognitive control. The present study opens up new perspectives regarding the use of MR to optimize cognitive performance during physical exercise.

  8. The Efficacy of Sucralfate and Chlorhexidine as an Oral Rinse in Patients with Recurrent Aphthous Stomatitis.

    Science.gov (United States)

    Soylu Özler, Gül; Okuyucu, Şemsettin; Akoğlu, Ertap

    2014-01-01

    Aim. In this study, we compared the efficacy of sucralfate suspension with chlorhexidine as an oral rinse in patients with recurrent aphthous stomatitis (RAS) in terms of pain relief and healing time. Materials and Methods. The subjects with a complaint of recurrent oral aphthous ulcers less than 1 cm in diameter on the first day of the occurrence of the ulcer and between 20 and 40 years were included in the study. Seventy patients completed the study. The patients were randomized into two groups as SCH group and CHX group. Changes in pain scores, healing time, and side effects of the treatments were evaluated. Results. The mean value of pain scores on the days after the treatment from the first day to the seventh day was significantly higher in CHX group than SCH group (P ≤ 0.05). On the seventh day after the treatment, the ulcers were completely reepithelialized in 23 patients in SCH group and in 19 patients in CHX group. The difference was statistically significant (P ≤ 0.05). In SCH group, the mean healing time of ulcers was 1.97 ± 1.56 days whereas it was 2.80 ± 3.00 days in CHX group. The difference was statistically significant (P ≤ 0.05). No side effects were recorded in either of the groups. Conclusion. Topical sucralfate suspension is an easy, safe, inexpensive, and effective treatment option for RAS to obtain pain relief and shorten the healing time of oral ulcers.

  9. The Efficacy of Sucralfate and Chlorhexidine as an Oral Rinse in Patients with Recurrent Aphthous Stomatitis

    Directory of Open Access Journals (Sweden)

    Gül Soylu Özler

    2014-01-01

    Full Text Available Aim. In this study, we compared the efficacy of sucralfate suspension with chlorhexidine as an oral rinse in patients with recurrent aphthous stomatitis (RAS in terms of pain relief and healing time. Materials and Methods. The subjects with a complaint of recurrent oral aphthous ulcers less than 1 cm in diameter on the first day of the occurrence of the ulcer and between 20 and 40 years were included in the study. Seventy patients completed the study. The patients were randomized into two groups as SCH group and CHX group. Changes in pain scores, healing time, and side effects of the treatments were evaluated. Results. The mean value of pain scores on the days after the treatment from the first day to the seventh day was significantly higher in CHX group than SCH group (P≤0.05. On the seventh day after the treatment, the ulcers were completely reepithelialized in 23 patients in SCH group and in 19 patients in CHX group. The difference was statistically significant (P≤0.05. In SCH group, the mean healing time of ulcers was 1.97±1.56 days whereas it was 2.80±3.00 days in CHX group. The difference was statistically significant (P≤0.05. No side effects were recorded in either of the groups. Conclusion. Topical sucralfate suspension is an easy, safe, inexpensive, and effective treatment option for RAS to obtain pain relief and shorten the healing time of oral ulcers.

  10. Processing results of 1800 gallons of mercury and radioactively contaminated mixed waste rinse solution

    International Nuclear Information System (INIS)

    Thiesen, B.P.

    1993-01-01

    Mercury-contaminated rinse solution was successfully treated at the Idaho National Engineering Laboratory. This waste was generated during the decontamination of the Heat Transfer Reactor Experiment 3 reactor shield tank. Approximately 6.8 m 3 (1,800 pi) of waste was generated and placed into 33 drums. Each drum contained precipitated sludge material ranging from 2--5 cm in depth, with the average depth of about 6 cm. The pH of each drum varied from 3--11. The bulk liquid waste had a mercury level of 7.0 mg/l, which exceeded the Resource Conservation and Recovery Act limit of 0.2 mg/l. The average liquid bulk radioactivity was about 2.1 pCi/mL while the average sludge contamination was about 13,800 pCi/g. Treatment of the waste required separation of the liquid from the sludge, filtration, pH adjustment, and ion exchange. The resulting solution after treatment had mercury levels at 0.0186 mg/l and radioactivity of 0.282 pCi/ml

  11. Efficacy of triphala mouth rinse (aqueous extracts) on dental plaque and gingivitis in children.

    Science.gov (United States)

    Bhattacharjee, Ritesh; Nekkanti, Sridhar; Kumar, Nikesh G; Kapuria, Ketan; Acharya, Shashidhar; Pentapati, Kalyana C

    2015-08-01

    The aim of the present study was to evaluate the efficacy of triphala mouth rinse (aqueous) in the reduction of plaque and gingivitis among children. The study was a randomized, double-blinded, controlled trial, with a total of 60 school children (n = 30 in each group; triphala and chlorhexidine groups). Plaque and gingival indices were used to evaluate baseline and follow-up plaque and gingivitis. A total of 57 children completed the study. Both chlorhexidine and triphala groups showed significantly lower mean gingival and plaque index scores at follow up than baseline (P gingival index between the two groups (P = 0.826). The percentage change in the mean plaque index was significantly higher in the chlorhexidine group compared to the triphala group (P = 0.048). The effectiveness of triphala in the reduction of plaque and gingivitis was comparable to chlorhexidine, and can be used for short-term purposes without potential side-effects. It is a cost-effective alternative in reducing plaque and gingivitis. © 2014 Wiley Publishing Asia Pty Ltd.

  12. Cognitive Performance Enhancement Induced by Caffeine, Carbohydrate and Guarana Mouth Rinsing during Submaximal Exercise.

    Science.gov (United States)

    Pomportes, Laura; Brisswalter, Jeanick; Casini, Laurence; Hays, Arnaud; Davranche, Karen

    2017-06-09

    The aim of this study was to investigate the influence of serial mouth rinsing (MR) with nutritional supplements on cognitive performance (i.e., cognitive control and time perception) during a 40-min submaximal exercise. Twenty-four participants completed 4 counterbalanced experimental sessions, during which they performed MR with either placebo (PL), carbohydrate (CHO: 1.6 g/25 mL), guarana complex (GUAc: 0.4 g/25 mL) or caffeine (CAF: 67 mg/25 mL) before and twice during exercise. The present study provided some important new insights regarding the specific changes in cognitive performance induced by nutritional supplements. The main results were: (1) CHO, CAF and GUA MR likely led participants to improve temporal performance; (2) CAF MR likely improved cognitive control; and (3) CHO MR led to a likely decrease in subjective perception of effort at the end of the exercise compared to PL, GUA and CAF. Moreover, results have shown that performing 40-min submaximal exercise enhances information processing in terms of both speed and accuracy, improves temporal performance and does not alter cognitive control. The present study opens up new perspectives regarding the use of MR to optimize cognitive performance during physical exercise.

  13. Silicon-micromachined microchannel plates

    CERN Document Server

    Beetz, C P; Steinbeck, J; Lemieux, B; Winn, D R

    2000-01-01

    Microchannel plates (MCP) fabricated from standard silicon wafer substrates using a novel silicon micromachining process, together with standard silicon photolithographic process steps, are described. The resulting SiMCP microchannels have dimensions of approx 0.5 to approx 25 mu m, with aspect ratios up to 300, and have the dimensional precision and absence of interstitial defects characteristic of photolithographic processing, compatible with positional matching to silicon electronics readouts. The open channel areal fraction and detection efficiency may exceed 90% on plates up to 300 mm in diameter. The resulting silicon substrates can be converted entirely to amorphous quartz (qMCP). The strip resistance and secondary emission are developed by controlled depositions of thin films, at temperatures up to 1200 deg. C, also compatible with high-temperature brazing, and can be essentially hydrogen, water and radionuclide-free. Novel secondary emitters and cesiated photocathodes can be high-temperature deposite...

  14. Create Your Plate

    Medline Plus

    Full Text Available ... In Memory In Honor Become a Member En Español Type 1 Type 2 About Us Online Community ... Page Text Size: A A A Listen En Español Create Your Plate Create Your Plate is a ...

  15. Create Your Plate

    Medline Plus

    Full Text Available ... Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal Planning ... Planning Meals Diabetes Meal Plans and a Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets ...

  16. Create Your Plate

    Medline Plus

    Full Text Available ... Planning Meals Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart- ... Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart-Healthy Foods ...

  17. Create Your Plate

    Medline Plus

    Full Text Available ... ready, you can try new foods within each food category. Try these seven steps to get started: Using your dinner plate, put a line down the middle of the plate. Then on one side, cut it ... and starchy foods. See this list of grains and starchy foods . ...

  18. An In Vitro Evaluation of Leakage of Two Etch and Rinse and Two Self-Etch Adhesives after Thermocycling

    OpenAIRE

    Geerts, Sabine; Bolette, Amandine; Seidel, Laurence; Guéders, Audrey

    2012-01-01

    Our experiment evaluated the microleakage in resin composite restorations bonded to dental tissues with different adhesive systems. 40 class V cavities were prepared on the facial and lingual surfaces of each tooth with coronal margins in enamel and apical margins in cementum (root dentin). The teeth were restored with Z100 resin composite bonded with different adhesive systems: Scotchbond Multipurpose (SBMP), a 3-step Etch and Rinse adhesive, Adper Scotchbond 1 XT (SB1), a 2-step Etch and Ri...

  19. Towards stacked zone plates

    International Nuclear Information System (INIS)

    Werner, S; Rehbein, S; Guttman, P; Heim, S; Schneider, G

    2009-01-01

    Fresnel zone plates are the key optical elements for soft and hard x-ray microscopy. For short exposure times and minimum radiation load of the specimen the diffraction efficiency of the zone plate objectives has to be maximized. As the efficiency strongly depends on the height of the diffracting zone structures the achievable aspect ratio of the nanostructures determines these limits. To reach aspect ratios ≥ 20:1 for high efficient optics we propose to superimpose zone plates on top of each other. With this multiplication approach the final aspect ratio is only limited by the number of stacked zone plate layers. For the stack process several nanostructuring process steps have to be developed and/or improved. Our results show for the first time two layers of zone plates stacked on top of each other.

  20. An In Vitro Evaluation of Leakage of Two Etch and Rinse and Two Self-Etch Adhesives after Thermocycling

    Science.gov (United States)

    Geerts, Sabine; Bolette, Amandine; Seidel, Laurence; Guéders, Audrey

    2012-01-01

    Our experiment evaluated the microleakage in resin composite restorations bonded to dental tissues with different adhesive systems. 40 class V cavities were prepared on the facial and lingual surfaces of each tooth with coronal margins in enamel and apical margins in cementum (root dentin). The teeth were restored with Z100 resin composite bonded with different adhesive systems: Scotchbond Multipurpose (SBMP), a 3-step Etch and Rinse adhesive, Adper Scotchbond 1 XT (SB1), a 2-step Etch and Rinse adhesive, AdheSE One (ADSE-1), a 1-step Self-Etch adhesive, and AdheSE (ADSE), a 2-step Self-Etch adhesive. Teeth were thermocycled and immersed in 50% silver nitrate solution. When both interfaces were considered, SBMP has exhibited significantly less microleakage than other adhesive systems (resp., for SB1, ADSE-1 and ADSE, P = 0.0007, P adhesives, microleakage was found greater at enamel than at dentin interfaces (for ADSE, P = 0.024 and for ADSE-1, P adhesive systems, there was no significant difference between enamel and dentin interfaces; (3) SBMP was found significantly better than other adhesives both at enamel and dentin interfaces. In our experiment Etch and Rinse adhesives remain better than Self-Etch adhesives at enamel interface. In addition, there was no statistical difference between 1-step (ADSE-1) and 2-step (ADSE) Self-Etch adhesives. PMID:22675358

  1. Does ErbiumiYttrium-Aluminum-Garnet Laser to Enamel improve the Performance of Etch-and-rinse and Universal Adhesives?

    Science.gov (United States)

    De Jesus Tavarez, Rudys R; Rodrigues, Lorrany Lc; Diniz, Ana C; Lage, Lucas M; Torres, Carlos Rg; Bandeca, Matheus C; Firoozmand, Leily M

    2018-03-01

    This study aims to evaluate the effect of erbium: Yttrium-aluminum-garnet (Er:YAG) laser irradiation on the enamel microshear bond strength (μSBS), followed by the utilization of etch-and-rinse and universal adhesive systems. A total of 32 molars were sectioned in the mesiodistal direction producing 64 samples that were randomized into two groups (n = 32): single bond 2 (SB2) (etch-and-rinse system; 3M), SB universal (SBU) (universal etching system; The SB2 and SBU groups were then divided into two subgroups (n = 16): (i) enamel was irradiated with an Er:YAG laser (λ = 2.94 μm, 60 mJ, 10 Hz), and (ii) enamel served as a control. The samples were restored with TPH3 (Dentsply), stored in artificial saliva for 24 hours, and subjected to a micro-shear test. Kruskal-Wallis (p enamel interface. The previous irradiation of enamel with Er:YAG laser does not interfere with the performance of simplified two-step etch-and-rinse and universal adhesive systems. The increasing use of Er:YAG laser is important to evaluate the influence of this irradiation on the adhesion of restorative materials. Thus, to obtain the longevity of the restorative procedures, it is necessary to know the result of the association of the present adhesive systems to the irradiated substrate.

  2. The effect of cetylpyridinium chloride-containing mouth rinses as adjuncts to toothbrushing on plaque and parameters of gingival inflammation: a systematic review

    NARCIS (Netherlands)

    Haps, S.; Slot, D.E.; Berchier, C.E.; van der Weijden, G.A.

    2008-01-01

    Objective: To review the literature concerning cetylpyridinium chloride (CPC) containing mouth rinses as effective adjuncts to toothbrushing in the prevention of plaque accumulation and gingival inflammation. Materials and methods: Medline and the Cochrane Central Register of Controlled Trials were

  3. Treatment techniques for the recycling of bottle washing water in the soft drinks industry.

    Science.gov (United States)

    Ramirez Camperos, E; Mijaylova Nacheva, P; Diaz Tapia, E

    2004-01-01

    The soft drink production is an important sector in the manufacturing industry of Mexico. Water is the main source in the production of soft drinks. Wastewater from bottle washing is almost 50% of the total wastewater generated by this industry. In order to reduce the consumption of water, the water of the last bottle rinse can be reused in to the bottle pre-rinse and pre-washing cycles. This work presents the characterization of the final bottle washing rinse discharge and the treatability study for the most appropriate treatment system for recycling. Average characteristics of the final bottle wash rinse were as follows: Turbidity 40.46 NTU, COD 47.7 mg/L, TSS 56 mg/L, TS 693.6 mg/L, electrical conductivity 1,194 microS/cm. The results of the treatability tests showed that the final rinse water can be used in the pre-rinse and pre-washing after removing the totality of the suspended solids, 80% of the COD and 75% of the dissolved solids. This can be done using the following treatment systems: filtration-adsorption-reverse osmosis, or filtration-adsorption-ion exchange. The installation of these treatment techniques in the soft drink industry would decrease bottle washing water consumption by 50%.

  4. Vortex Dynamics of Asymmetric Heave Plates

    Science.gov (United States)

    Rusch, Curtis; Maurer, Benjamin; Polagye, Brian

    2017-11-01

    Heave plates can be used to provide reaction forces for wave energy converters, which harness the power in ocean surface waves to produce electricity. Heave plate inertia includes both the static mass of the heave plate, as well as the ``added mass'' of surrounding water accelerated with the object. Heave plate geometries may be symmetric or asymmetric, with interest in asymmetric designs driven by the resulting hydrodynamic asymmetry. Limited flow visualization has been previously conducted on symmetric heave plates, but flow visualization of asymmetric designs is needed to understand the origin of observed hydrodynamic asymmetries and their dependence on the Keulegan-Carpenter number. For example, it is hypothesized that the time-varying added mass of asymmetric heave plates is caused by vortex shedding, which is related to oscillation amplitude. Here, using direct flow visualization, we explore the relationship between vortex dynamics and time-varying added mass and drag. These results suggest potential pathways for more advanced heave plate designs that can exploit vortex formation and shedding to achieve more favorable hydrodynamic properties for wave energy converters.

  5. Comparative effect of fluoride, essential oil and chlorhexidine mouth rinses on dental plaque and gingivitis in patients with and without dental caries: a randomized controlled trial.

    Science.gov (United States)

    Charugundla, B R; Anjum, S; Mocherla, M

    2015-05-01

    The objective of this study was to compare the effectiveness of fluoride, essential oil (EO) and chlorhexidine (CHX)-containing mouth rinses on dental plaque and gingivitis and to compare their relative efficacy in patients with and without dental caries. A randomized, controlled, double- blind, crossover clinical trial was conducted for a period of 8 weeks. Thiry-six qualifying subjects, aged 12-44 years, were included in the study. Subjects were divided into caries and caries-free groups and were randomly assigned to one of the following mouth rinse groups: fluoride; EO; CHX and saline as negative control. Subjects used their respective mouth rinse for a period of 7-days each with 1-week wash-out periods. Primary efficacy variables were Quigley-Hein plaque index (PI) and Loe and Silness gingival index. Fluoride and CHX mouth rinses showed significant reduction in plaque after use of mouth rinses (P gingivitis (P > 0.05). Further significant differences were found in reducing plaque and gingivitis in caries-free subjects in comparison to those with caries (P gingivitis especially in caries-free subjects in comparison to those with caries, and amongst the three, fluoride and CHX proved to be more effective than EO mouth rinse. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Comparative evaluation of effectiveness between Aloe vera and two commercially available mouth rinses on plaque and gingival status: A randomized control trial

    Directory of Open Access Journals (Sweden)

    Sujal Parkar

    2011-01-01

    Full Text Available Aim: Aloe vera has been suggested for a wide variety of ailments, but its use in dentistry is limited. The purpose of the study was to evaluate the effect of A. vera on the reduction of plaque and gingivitis. This effect was evaluated by randomized, parallel and double-blind clinical trial. Materials and Methods: Total 30 subjects were randomly allocated into three groups; 10 in each for (i chlorhexidine, (ii tea tree leaves and (iii A. vera. Plaque index and gingival index were assessed at days 0 and 21. Subjects were asked to rinse their mouth with the mouth rinse, twice a day, during a 21-day period. Paired t-test was used test the mean difference at 0 day and 21 days. One way analysis of variance was used to check the mean difference among three mouth rinses. Results: All three mouth rinses shows a significant reduction from 0 day to 21 days (P 0.05. Conclusion: A. vera mouth rinse was as effective as two commercially popular mouth rinses in controlling plaque and gingivitis.

  7. Anisotropic elastic plates

    CERN Document Server

    Hwu, Chyanbin

    2010-01-01

    As structural elements, anisotropic elastic plates find wide applications in modern technology. The plates here are considered to be subjected to not only in plane load but also transverse load. In other words, both plane and plate bending problems as well as the stretching-bending coupling problems are all explained in this book. In addition to the introduction of the theory of anisotropic elasticity, several important subjects have are discussed in this book such as interfaces, cracks, holes, inclusions, contact problems, piezoelectric materials, thermoelastic problems and boundary element a

  8. High loading uranium plate

    International Nuclear Information System (INIS)

    Wiencek, T.C.; Domagala, R.F.; Thresh, H.R.

    1990-01-01

    Two embodiments of a high uranium fuel plate are disclosed which contain a meat comprising structured uranium compound confined between a pari of diffusion bonded ductile metal cladding plates uniformly covering the meat, the meat hiving a uniform high fuel loading comprising a content of uranium compound greater than about 45 Vol. % at a porosity not greater than about 10 Vol. %. In a first embodiment, the meat is a plurality of parallel wires of uranium compound. In a second embodiment, the meat is a dispersion compact containing uranium compound. The fuel plates are fabricated by a hot isostatic pressing process

  9. Effects of caffeine and maltodextrin mouth rinsing on P300, brain imaging, and cognitive performance.

    Science.gov (United States)

    De Pauw, K; Roelands, B; Knaepen, K; Polfliet, M; Stiens, J; Meeusen, R

    2015-03-15

    Caffeine (CAF) and maltodextrin (MALT) mouth rinses (MR) improve exercise performance. The current experiment aims to determine the effect of CAF and MALT MR on cognitive performance and brain activity. Ten healthy male subjects (age 27 ± 3 yr) completed three experimental trials. Each trial included four Stroop tasks: two familiarization tasks, and one task before and one task after an MR period. The reaction time (in milliseconds) and accuracy (percent) of simple, congruent, and incongruent stimuli were assessed. Electroencephalography was applied throughout the experiment to record brain activity. The amplitudes and latencies of the P300 were determined during the Stroop tasks before and after the MR period. Subjects received MR with CAF (0.3 g/25 ml), MALT (1.6 g/25 ml), or placebo (PLAC) in a randomized, double-blind, crossover design. During MR, the brain imaging technique standardized low-resolution brain electromagnetic tomography was applied. Magnitude-based inferences showed that CAF MR is likely trivial (63.5%) and likely beneficial (36.4%) compared with PLAC MR, and compared with MALT MR likely beneficial to reaction time on incongruent stimuli (61.6%). Additionally, both the orbitofrontal and dorsolateral prefrontal cortex were activated only during CAF MR, potentially explaining the likely beneficial effect on reaction times. MALT MR increased brain activity only within the orbitofrontal cortex. However, this brain activation did not alter the reaction time. Furthermore, no significant differences in the accuracy of stimuli responses were observed between conditions. In conclusion, only CAF MR exerted a likely beneficial effect on reaction time due to the subsequent activation of both the orbitofrontal and dorsolateral prefrontal cortexes. Copyright © 2015 the American Physiological Society.

  10. Processing results of 1,800 gallons of mercury and radioactively contaminated mixed waste rinse solution

    International Nuclear Information System (INIS)

    Thiesen, B.P.

    1993-01-01

    The mercury-contaminated rinse solution (INEL waste ID number-sign 123; File 8 waste) was successfully treated at the Idaho National Engineering Laboratory (INEL). This waste was generated during the decontamination of the Heat Transfer Reactor Experiment 3 (HTRE-3) reactor shield tank. Approximately 1,800 gal of waste was generated and was placed into 33 drums. Each drum contained precipitated sludge material ranging from 1--10 in. in depth, with the average depth of about 2.5 in. The pH of each drum varied from 3--11. The bulk liquid waste had a mercury level of 7.0 mg/l, which exceeded the Resource Conservation and Recovery Act (RCRA) limit of 0.2 mg/l. The average liquid bulk radioactivity was about 2.1 pCi/ml, while the average sludge contamination was about 13,800 pci/g. Treatment of the waste required separation of the liquid from the sludge, filtration, pH adjustment, and ion exchange. Because of difficulties in processing, three trials were required to reduce the mercury levels to below the RCRA limit. In the first trial, insufficient filtration of the waste allowed solid particulate produced during pH adjustment to enter into the ion exchange columns and ultimately the waste storage tank. In the second trial, the waste was filtered down to 0.1 μ to remove all solid mercury compounds. However, before filtration could take place, a solid mercury complex dissolved and mercury levels exceeded the RCRA limit after filtration. In the third trial, the waste was filtered through 0.3-A filters and then passed through the S-920 resin to remove the dissolved mercury. The resulting solut

  11. Heat insulating plates

    Energy Technology Data Exchange (ETDEWEB)

    Allan, J.A.F.

    1976-10-28

    Micro-porous insulation plates are dealt with, for example, how they are used in the insulation of heat storage devices. Since one side of such plates is exposed to a temperature of over 700/sup 0/C, a shrinkage of the glass texture of the covering can occur, which can exceed the shrinkage of the inner micro-porous material, so that cracks and splits in the high temperature side of the covering can come about. The task of the invention is to design the plate in such a way as to prevent this from happening. For this purpose the plate is provided, according to invention specifications, with flutes, waves, ribs, waffle or grid patterns and the covering is set into the recesses originating from this.

  12. Create Your Plate

    Medline Plus

    Full Text Available ... Plate is a simple and effective way to manage your blood glucose levels and lose weight. With ... been easier. It can be a challenge to manage portion control wherever you are. Now, our best- ...

  13. Create Your Plate

    Medline Plus

    Full Text Available ... Food Planning Meals Diabetes Meal Plans and a Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart-Healthy Foods donate en -- A Future Without Diabetes - a- ...

  14. Create Your Plate

    Medline Plus

    Full Text Available ... Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ... Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart- ...

  15. Create Your Plate

    Medline Plus

    Full Text Available ... Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ... Planning Meals Diabetes Meal Plans and a Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets ...

  16. Create Your Plate

    Medline Plus

    Full Text Available ... Children and Type 2 Diabetes Know Your Rights Employment Discrimination Health Care Professionals Law Enforcement Driver's License ... blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ...

  17. Create Your Plate

    Medline Plus

    Full Text Available ... diabetes. Other Ways to Give Become a Member Vehicle Donation Planned Giving Options Memorial Giving Brochures & Envelopes ... to manage your blood glucose levels and lose weight. With this method, you fill your plate with ...

  18. Create Your Plate

    Medline Plus

    Full Text Available ... breast cancer and AIDS combined. Your gift today will help us get closer to curing diabetes and ... on one side, cut it again so you will have three sections on your plate. Fill the ...

  19. Create Your Plate

    Medline Plus

    Full Text Available ... Recipes Association Cookbook Recipes Planning Meals Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning ... serving of dairy or both as your meal plan allows. Choose healthy fats in small amounts. For ...

  20. Create Your Plate

    Medline Plus

    Full Text Available ... Count Glycemic Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type 1 Diabetes Get Started Safely ... blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ...

  1. Create Your Plate

    Medline Plus

    Full Text Available ... these seven steps to get started: Using your dinner plate, put a line down the middle of ... Fitness Food Recipes Planning Meals What Can I Eat Weight Loss Fitness In My Community Calendar of ...

  2. Create Your Plate

    Medline Plus

    Full Text Available ... Food MyFoodAdvisor Recipes Association Cookbook Recipes Planning Meals Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal ...

  3. Create Your Plate

    Medline Plus

    Full Text Available ... for Association Events Messaging Tools Recruiting Advocates Local Market Planning Training Webinars News & Events Advocacy News Call ... Meals > Create Your Plate Share: Print Page Text Size: A A A Listen En Español Create Your ...

  4. Create Your Plate

    Medline Plus

    Full Text Available ... Us in the Fight for a Cure Your tax-deductible gift today can fund critical diabetes research ... Close www.diabetes.org > Food and Fitness > Food > Planning Meals > Create Your Plate Share: Print Page Text ...

  5. Create Your Plate

    Medline Plus

    Full Text Available ... critical diabetes research and support vital diabetes education services that improve the lives of those with diabetes. $50 $100 $250 $500 Other Other Ways ... Meals > Create Your Plate ...

  6. Create Your Plate

    Medline Plus

    Full Text Available ... 800-342-2383) Give by Mail Close ... your plate with more non-starchy veggies and smaller portions of starchy foods and protein—no special tools or counting required! You can ...

  7. Humvee Armor Plate Drilling

    National Research Council Canada - National Science Library

    2004-01-01

    When drilling holes in hard steel plate used in up-armor kits for Humvee light trucks, the Anniston Army Depot, Anniston, Alabama, requested the assistance of the National Center for Defense Manufacturing and Machining (NCDMM...

  8. Create Your Plate

    Medline Plus

    Full Text Available ... Easy Advocacy Checklists for Association Events Messaging Tools Recruiting Advocates Local Market Planning Training Webinars News & Events ... blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ...

  9. Create Your Plate

    Medline Plus

    Full Text Available ... blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ... Complications Health Insurance For Parents & Kids Know Your Rights We Can Help Enroll in the Living WIth ...

  10. Create Your Plate

    Medline Plus

    Full Text Available ... blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ... today and help fund grants supporting next generation scientists. Donate Today We Can Help - we-can-help. ...

  11. BAO Plate Archive Project

    Science.gov (United States)

    Mickaelian, A. M.; Gigoyan, K. S.; Gyulzadyan, M. V.; Paronyan, G. M.; Abrahamyan, H. V.; Andreasyan, H. R.; Azatyan, N. M.; Kostandyan, G. R.; Samsonyan, A. L.; Mikayelyan, G. A.; Farmanyan, S. V.; Harutyunyan, V. L.

    2017-12-01

    We present the Byurakan Astrophysical Observatory (BAO) Plate Archive Project that is aimed at digitization, extraction and analysis of archival data and building an electronic database and interactive sky map. BAO Plate Archive consists of 37,500 photographic plates and films, obtained with 2.6m telescope, 1m and 0.5m Schmidt telescopes and other smaller ones during 1947-1991. The famous Markarian Survey (or the First Byurakan Survey, FBS) 2000 plates were digitized in 2002-2005 and the Digitized FBS (DFBS, www.aras.am/Dfbs/dfbs.html) was created. New science projects have been conducted based on this low-dispersion spectroscopic material. Several other smaller digitization projects have been carried out as well, such as part of Second Byurakan Survey (SBS) plates, photographic chain plates in Coma, where the blazar ON 231 is located and 2.6m film spectra of FBS Blue Stellar Objects. However, most of the plates and films are not digitized. In 2015, we have started a project on the whole BAO Plate Archive digitization, creation of electronic database and its scientific usage. Armenian Virtual Observatory (ArVO, www.aras.am/Arvo/arvo.htm) database will accommodate all new data. The project runs in collaboration with the Armenian Institute of Informatics and Automation Problems (IIAP) and will continues during 4 years in 2015-2018. The final result will be an Electronic Database and online Interactive Sky map to be used for further research projects. ArVO will provide all standards and tools for efficient usage of the scientific output and its integration in international databases.

  12. Neutron imaging plates

    International Nuclear Information System (INIS)

    Niimura, Nobuo

    1995-01-01

    Imaging plates have been used in the field of medical diagnosis since long ago, but their usefulness was verified as the two-dimensional detector for analyzing the X-ray crystalline structure of high bio molecules like protein, and they have contributed to the remarkable progress in this field. The great contribution is due to the excellent features, such as the detection efficiency of about 100%, the positional resolution smaller than 0.2 mm, the dynamic range of five digits, and the area of several hundreds mm square. The neutron imaging plates have not yet obtained the sufficient results. It was planned to construct the neutron diffractometer for biological matters, and to put imaging plate neutron detectors (IP-ND) to practical use as the detector. The research on the development of IP-NDs was carried out, and the IPp-NDs having the performance comparable with that for X-ray were able to be produced. Imaging plates are the integral type two-dimensional radiation detector using photostimulated luminescence matters, and their principle is explained. As to neutron imaging plates, the converter, neutron detection efficiency and the flight of secondary particles in photo-stimulated luminescence matters are described. As for the present state of development of neutron imaging plates, the IP-NDs made for trial, the dynamic range, the positional resolution, the detection efficiency and the kinds of converters, and the application of IP-NDs are reported. (K.I.)

  13. The effect of 17% EDTA and MTAD on smear layer removal and on erosion of root canal dentin when used as final rinse: An in vitro SEM study

    Directory of Open Access Journals (Sweden)

    Vishal A Mahajan

    2010-01-01

    Full Text Available Background: The aim of the present study was to evaluate and compare the ability of a mixture of tetracycline isomer, citric acid and detergent (MTAD and ethylene diamine tetra-acetic acid (EDTA in removing the smear layer along with their effects on peritubular and intertubular dentinal structures by scanning electron microscopic (SEM examination. Materials and Methods: Thirty recently extracted maxillary and mandibular single-rooted human teeth were divided into 3 groups and prepared to an apical size of 30. In Group 1, 2, and 3, MTAD, EDTA, and distilled water were used, respectively, as a final rinse solution to remove the smear layer. The specimens were subjected to SEM evaluation for the presence or absence of the smear layer and degree of erosion using a scoring system. Results: The result showed that MTAD shows better smear layer removing ability and does not significantly change the structure of dentinal tubules. Conclusion: MTAD is an efficient solution for the removal of the smear layer, especially in the apical third of root canals, and does not significantly change the structure of the dentinal tubules.

  14. Plate tectonics, habitability and life

    Science.gov (United States)

    Spohn, Tilman; Breuer, Doris

    2016-04-01

    The role of plate tectonics in defining habitability of terrestrial planets is being increasingly discussed (e.g., Elkins-Tanton, 2015). Plate tectonics is a significantly evolved concept with a large variety of aspects. In the present context, cycling of material between near surface and mantle reservoirs is most important. But increased heat transport through mixing of cold lithosphere with the deep interior and formation of continental crust may also matter. An alternative mechanism of material cycling between these reservoirs is hot-spot volcanism combined with crust delamination. Hot-spot volcanism will transport volatiles to the atmosphere while delamination will mix crust, possibly altered by sedimentation and chemical reactions, with the mantle. The mechanism works as long as the stagnant lithosphere plate has not grown thicker than the crust and as long as volcanic material is added onto the crust. Thermal evolution studies suggest that the mechanism could work for the first 1-2 Ga of planetary evolution. The efficiency of the mechanism is limited by the ratio of extrusive to intrusive volcanism, which is thought to be less than 0.25. Plate tectonics would certainly have an advantage by working even for more evolved planets. A simple, most-used concept of habitability requires the thermodynamic stability of liquid water on the surface of a planet. Cycling of CO2between the atmosphere, oceans and interior through subduction and surface volcanism is an important element of the carbonate-silicate cycle, a thermostat feedback cycle that will keep the atmosphere from entering into a runaway greenhouse. Calculations for a model Earth lacking plate tectonics but degassing CO2, N, and H2O to form a surface ocean and a secondary atmosphere (Tosi et al, 2016) suggest that liquid water can be maintained on the surface for 4.5Ga. The model planet would then qualify as habitable. It is conceivable that the CO2 buffering capability of its ocean together with silicate

  15. Effects of carbohydrate mouth rinse and caffeine on high-intensity interval running in a fed state.

    Science.gov (United States)

    Devenney, Simon; Mangan, Shane; Shortall, Marcus; Collins, Kieran

    2018-05-01

    The current study aims to identify if mouth rinsing with a 6% carbohydrate mouth-rinse (CMR) solution and mouth rinsing and ingestion of caffeine (CMR+CAFF) can affect exercise performance during steady-state (SS) running and high-intensity intervals (HIIT) in comparison with a 0% control solution (PLA) when in a fed state. Eight recreationally trained males completed 3 trials (CMR, CMR+CAFF, and PLA) of 45 min SS running and an HIIT protocol (90% peak treadmill velocity) until fatigue in a double blinded, repeated-measures study. Participants ingested a capsule of either CAFF or PLA before and after SS. Participants received a 25-mL bolus of carbohydrate solution (CMR and CMR+CAFF trials) or taste-matched PLA (PLA trial) prior to HIIT protocol and after every second effort. Heart rate and lactate responses were recorded throughout the SS and HIIT protocol. CMR+CAFF was significantly different when compared with PLA (p = 0.001; Cohens d = 1.34) and CMR (p = 0.031; Cohens d = 0.87) in relation to distance covered before fatigue. Although there was no significant difference between CMR and PLA, there was a small benefit for CMR (p = 0.218; Cohens d = 0.46). Results indicate that CMR and ingestion of CAFF leads to improvements in performance during interval sessions while participants were in a fed state. These findings indicate that the regular use of CMR can decrease the risk of gastrointestinal distress reported by athletes, which can be applicable to athletes in a real-world setting.

  16. Cadmium plating replacements

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, M.J.; Groshart, E.C.

    1995-03-01

    The Boeing Company has been searching for replacements to cadmium plate. Two alloy plating systems seem close to meeting the needs of a cadmium replacement. The two alloys, zinc-nickel and tin-zinc are from alloy plating baths; both baths are neutral pH. The alloys meet the requirements for salt fog corrosion resistance, and both alloys excel as a paint base. Currently, tests are being performed on standard fasteners to compare zinc-nickel and tin-zinc on threaded hardware where cadmium is heavily used. The Hydrogen embrittlement propensity of the zinc-nickel bath has been tested, and just beginning for the tin-zinc bath. Another area of interest is the electrical properties on aluminum for tin-zinc and will be discussed. The zinc-nickel alloy plating bath is in production in Boeing Commercial Airplane Group for non-critical low strength steels. The outlook is promising that these two coatings will help The Boeing Company significantly reduce its dependence on cadmium plating.

  17. Verification of an optimized condition for low residual stress employed water-shower cooling during welding in austenitic stainless steel plates

    International Nuclear Information System (INIS)

    Yanagida, N.; Enomoto, K.; Anzai, H.

    2004-01-01

    To reduce tensile residual stress in a welded region, we have developed a new cooling method that uses a water-shower behind the welding torch. When this method is applied to the welding of austenitic stainless steel, the welding and cooling conditions mainly determine how much the residual stress can be reduced. To optimize these conditions, we first used a robust design method to determine the effects of the preheating temperature, the heat input quantity, and the water-shower area on the residual stress, and found that, to decrease the tensile residual stress, the preheating temperature should be high, the heat input low, and the water-shower area large. To confirm the effectiveness of these optimized conditions, the residual stresses under optimized or non-optimized conditions were measured experimentally. It was found that the residual stresses were tensile under the non-optimized conditions, but compressive under the optimized ones. These measurements agree well with the 3D-FEM analyses. It can therefore be concluded that the optimized conditions are valid and appropriate for reducing residual stress in an austenitic stainless-steel weld. (orig.)

  18. Bending and stretching of plates

    CERN Document Server

    Mansfield, E H; Hemp, W S

    1964-01-01

    The Bending and Stretching of Plates deals with elastic plate theory, particularly on small- and large-deflexion theory. Small-deflexion theory concerns derivation of basic equations, rectangular plates, plates of various shapes, plates whose boundaries are amenable to conformal transformation, plates with variable rigidity, and approximate methods. Large-deflexion theory includes general equations and some exact solutions, approximate methods in large-deflexion theory, asymptotic large-deflexion theories for very thin plates. Asymptotic theories covers membrane theory, tension field theory, a

  19. Plating on Zircaloy-2

    International Nuclear Information System (INIS)

    Dini, J.W.; Johnson, H.R.; Jones, A.

    1979-03-01

    Zircaloy-2 is a difficult alloy to coat with an adherent electroplate because it easily forms a tenacious oxide film in air and aqueous solutions. Procedures reported in the literature and those developed at SLL for surmounting this problem were investigated. The best results were obtained when specimens were first etched in either an ammonium bifluoride/sulfuric acid or an ammonium bifluoride solution, plated, and then heated at 700 0 C for 1 hour in a constrained condition. Machining threads in the Zircaloy-2 for the purpose of providing sites for mechanical interlocking of the plating also proved satisfactory

  20. Hydrodynamics of a flexible plate between pitching rigid plates

    Science.gov (United States)

    Kim, Junyoung; Kim, Daegyoum

    2017-11-01

    The dynamics of a flexible plate have been studied as a model problem in swimming and flying of animals and fluid-structure interaction of plants and flags. Motivated by fish schooling and an array of sea grasses, we investigate the dynamics of a flexible plate closely placed between two pitching rigid plates. In most studies on passive deformation of the flexible plate, the plate is immersed in a uniform flow or a wavy flow. However, in this study, the flexible plate experiences periodic deformation by the oscillatory flow generated by the prescribed pitching motion of the rigid plates. In our model, the pitching axes of the rigid plates and the clamping position of the flexible plate are aligned on the same line. The flexible plate shows various responses depending on length and pitching frequency of rigid plates, thickness of a flexible plate, and free-stream velocity. To find the effect of each variable on the response of the flexible plate, amplitude of a trailing edge and modal contribution of a flapping motion are compared, and flow structure around the flexible plate is examined.

  1. Influence of chlorhexidine and/or ethanol treatment on bond strength of an etch-and-rinse adhesive to dentin: an in vitro and in situ study.

    Science.gov (United States)

    Simões, D M S; Basting, R T; Amaral, F L B; Turssi, C P; França, F M G

    2014-01-01

    The aim of this study was to evaluate the effect of a chlorhexidine and/or ethanol application on the bond strength of an etch-and-rinse, hydrophobic adhesive system either under in vitro aging or in situ cariogenic challenge. The dentin surface of 36 human third molars were flattened and allocated into four groups to be treated with chlorhexidine, ethanol, or chlorhexidine + ethanol or left unexposed to any solution (control) (n=9). Then, a resin composite restoration was made on the dentin surface and longitudinal sticks were obtained. Sticks from each tooth were assigned to three test conditions: stored in water in vitro for 24 hours, stored in water in vitro for 6 months, or worn in situ for 14 days. During in situ wear time, a high-cariogenic challenge condition was simulated. Specimens were tested for microtensile bond strength (μTBS). Multivariate analysis of variance and Tukey's test showed that chlorhexidine, ethanol, or chlorhexidine + ethanol did not affect the μTBS. The in vitro μTBS values were significantly lower for the specimens stored for 6 months than for those stored for 24 hours. Intermediate μTBS values were shown by the specimens worn in situ. Thus, use of chlorhexidine and/or ethanol was incapable of containing the degradation at the bond interface in the in vitro model. The in situ model was capable of reducing bond strength similarly to the in vitro/6 months model. Despite this, the in situ bond strength was still similar to that of the in vitro/24-hour model.

  2. Sage tea-thyme-peppermint hydrosol oral rinse reduces chemotherapy-induced oral mucositis: A randomized controlled pilot study.

    Science.gov (United States)

    Mutluay Yayla, Ezgi; Izgu, Nur; Ozdemir, Leyla; Aslan Erdem, Sinem; Kartal, Murat

    2016-08-01

    This pilot study aimed to investigate the preventive effect of sage tea-thyme-peppermint hydrosol oral rinse used in conjunction with basic oral care on chemotherapy-induced oral mucositis. An open-label randomized controlled study. Two oncology hospitals in Ankara, Turkey. Patients receiving 5-fluorouracil-based chemotherapy regimens were divided into the intervention group (N=30) and control group (N=30). Basic oral care was prescribed to the control group, while the intervention group was prescribed sage tea-thyme-peppermint hydrosol in addition to basic oral care. All patients were called to assess their compliance with the study instructions on day 5 and 14. Oral mucositis was evaluated using an inspection method or by assessing oral cavity photos based on the World Health Organization oral toxicity scale on day 5 and 14. Most of the patients in the intervention group did not develop oral mucositis on day 5. In addition, the incidence of grade 1 oral mucositis was statistically lower in the intervention group (10%) than the control group (53.3%) on day 5. By day 14, the majority of patients in both the groups had grade 0 oral mucositis. Sage tea-thyme-peppermint hydrosol oral rinse has promising results in alleviating oral mucositis. This hydrosol can be recommended for clinical use as it is well tolerated and cost-effective. However, further randomized controlled trials are needed to support the study. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Oral fluoride levels 1 h after use of a sodium fluoride rinse: effect of sodium lauryl sulfate.

    Science.gov (United States)

    Vogel, Gerald L; Schumacher, Gary E; Chow, Laurence C; Tenuta, Livia M A

    2015-01-01

    Increasing the concentration of free fluoride in oral fluids is an important goal in the use of topical fluoride agents. Although sodium lauryl sulfate (SLS) is a common dentifrice ingredient, the influence of this ion on plaque fluid and salivary fluid fluoride has not been examined. The purpose of this study was to investigate the effect of SLS on these parameters and to examine the effect of this ion on total (or whole) plaque fluoride, an important source of plaque fluid fluoride after a sufficient interval following fluoride administration, and on total salivary fluoride, a parameter often used as a surrogate measure of salivary fluid fluoride. Ten subjects accumulated plaque for 48 h before rinsing with a 12 mmol/l NaF (228 µg/g F) rinse containing or not containing 0.5% (w/w) SLS. SLS had no statistically significant effect on total plaque and total saliva fluoride but significantly increased salivary fluid and plaque fluid fluoride (by 147 and 205%, respectively). These results suggest that the nonfluoride components of topical agents can be manipulated to improve the fluoride release characteristics from oral fluoride reservoirs and that statistically significant change may be observed in plaque fluid and salivary fluid fluoride concentrations that may not be observed in total plaque and total saliva fluoride concentrations.

  4. Hypermethylated ZNF582 and PAX1 genes in mouth rinse samples as biomarkers for oral dysplasia and oral cancer detection.

    Science.gov (United States)

    Cheng, Shih-Jung; Chang, Chi-Feng; Ko, Hui-Hsin; Lee, Jang-Jaer; Chen, Hsin-Ming; Wang, Huei-Jen; Lin, Hsiao-Shan; Chiang, Chun-Pin

    2018-02-01

    Effective biomarkers for oral cancer screening are important for early diagnosis and treatment of oral cancer. Oral epithelial cell samples collected by mouth rinse were obtained from 65 normal control subjects, 108 patients with oral potentially malignant disorders, and 94 patients with oral squamous cell carcinoma (OSCC). Methylation levels of zinc-finger protein 582 (ZNF582) and paired-box 1 (PAX1) genes were quantified by real-time methylation-specific polymerase chain reaction after bisulfite conversion. An abrupt increase in methylated ZNF582 (ZNF582 m ) and PAX1 (PAX1 m ) levels and positive rates from mild dysplasia to moderate/severe dysplasia, indicating that both ZNF582 m and PAX1 m are effective biomarkers for differentiating moderate dysplasia or worse (MODY+) oral lesions. When ZNF582 m /PAX1 m tests were used for identifying MODY+ oral lesions, the sensitivity, specificity, and odds ratio (OR) were 0.65/0.64, 0.75/0.82, and 5.6/8.0, respectively. Hypermethylated ZNF582 and PAX1 genes in oral epithelial cells collected by mouth rinse are effective biomarkers for the detection of oral dysplasia and oral cancer. © 2017 Wiley Periodicals, Inc.

  5. Hydrolytic stability of three-step etch-and-rinse adhesives in occlusal class-I cavities.

    Science.gov (United States)

    De Munck, Jan; Mine, Atsushi; Vivan Cardoso, Marcio; Van Landuyt, Kirsten L; Lührs, Anne-Katrin; Poitevin, André; Hanabusa, Masao; Kuboki, Takuo; Van Meerbeek, Bart

    2013-11-01

    A dental adhesive without small and hydrophilic monomers such as 2-hydroxyethyl methacrylate (HEMA) and triethylene glycol dimethacrylate (TEGDMA) would be beneficial in order to avoid contact allergies. However, these monomers are important to increase infiltration and polymerization of the adhesive. Therefore, the purpose of this study was to evaluate the bonding effectiveness and bond durability of a more hydrophobic and biocompatible adhesive as compared to a conventional three-step etch-and-rinse adhesive. Sixteen non-carious human third molars were used to determine the micro-tensile bond strength testing (μTBS) and interfacial ultrastructure by transmission electron microscopy (TEM) of the more hydrophobic cmf adhesive system (Saremco) adhesive as compared to the control OptiBond FL (Kerr). The more hydrophobic and biocompatible three-step etch-and-rinse adhesive was able to produce a reasonable short-time bonding effectiveness. In the long term, the collagen fibrils in the hybrid layer were not effectively protected and were prone to hydrolytic degradation. As a result, long-term bonding effectiveness of this novel adhesive was very low. Application of a more hydrophobic adhesive without altering the application procedure considerably results in a reduced durability of the created bond Omitting small and hydrophilic components from the adhesive formulation may impair the durability of your composite restoration.

  6. Create Your Plate

    Medline Plus

    Full Text Available ... meal-planning, . In this section Food Planning Meals Diabetes Meal Plans and a Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart-Healthy Foods donate en -- A Future Without Diabetes - a-future-without-diabetes-2.html A Future ...

  7. Create Your Plate

    Medline Plus

    Full Text Available ... tool is not to scale because of the differences in types of vegetables. When creating your plate ... function (data) { $('#survey-errors').remove(); $('.survey-form .form-group .survey-alert-wrap').remove(); if (data.submitSurveyResponse.success == ' ...

  8. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart-Healthy Foods donate en -- A Future Without Diabetes - a-future-without-diabetes-2.html A Future Without Diabetes Donate towards research today and your gift will be matched. Donate ...

  9. Create Your Plate

    Medline Plus

    Full Text Available ... Planning Meals > Create Your Plate Share: Print Page Text Size: A A A Listen En Español Create ... Type 2 Education Series Hear audio clips and full recordings of past Q&A events at your ...

  10. Create Your Plate

    Medline Plus

    Full Text Available ... 1 Type 2 About Us Online Community Meal Planning Sign In Search: Search More Sites Search ≡ Are ... Fitness Home Food MyFoodAdvisor Recipes Association Cookbook Recipes Planning Meals Diabetes Meal Plans Create Your Plate Gluten ...

  11. Create Your Plate

    Medline Plus

    Full Text Available ... tax-deductible gift today can fund critical diabetes research and support vital diabetes education services that improve the ... effective way to manage your blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ...

  12. Microchannel plate photodetectors

    International Nuclear Information System (INIS)

    Majka, R.

    1977-01-01

    A review is given the status of development work on photodetectors using microchannel plates (MCP) as the electron gain element. Projections are made and opinions are presented on what might be available in the next few years. Several uses for these devices at ISABELLE are mentioned

  13. Parallel plate detectors

    International Nuclear Information System (INIS)

    Gardes, D.; Volkov, P.

    1981-01-01

    A 5x3cm 2 (timing only) and a 15x5cm 2 (timing and position) parallel plate avalanche counters (PPAC) are considered. The theory of operation and timing resolution is given. The measurement set-up and the curves of experimental results illustrate the possibilities of the two counters [fr

  14. Flat plate collector. Solarflachkollektor

    Energy Technology Data Exchange (ETDEWEB)

    Raab, N

    1979-03-29

    The invention refers to a flat solar collector with an absorber plate, which is arranged on a support and is covered by a transparent window, between which and the plate there is an air space. The previously known structures of this type had the disadvantage that the thermal expansion of the enclosed air caused considerable difficulties. The purpose of the invention is therefore to create a collector, which can be used on the modular system, retains its properties and is safe in spite of the great temperature variations. According to the invention this problem is solved by providing a compensating space in the collector, which is separated by a diaphragm from the airspace between the plate and the covering window. The airspace therefore remains sealed against the atmosphere, so that no dirt, corrosion of the inside and no condensation can reduce the efficiency of the collector. A rise in pressure due to an increase in temperature is immediately reduced by expansion of the diaphragm, which enters the compensation space. In order to increase the pressure in the airspace above the plate for increases in temperature, the compensation space is connected to the atmosphere. The diaphragm can be mirrored on the side towards the absorber, which makes the diaphragm into an insulating element, as it reflects radiated heat from the absorber.

  15. Silicon-micromachined microchannel plates

    International Nuclear Information System (INIS)

    Beetz, Charles P.; Boerstler, Robert; Steinbeck, John; Lemieux, Bryan; Winn, David R.

    2000-01-01

    Microchannel plates (MCP) fabricated from standard silicon wafer substrates using a novel silicon micromachining process, together with standard silicon photolithographic process steps, are described. The resulting SiMCP microchannels have dimensions of ∼0.5 to ∼25 μm, with aspect ratios up to 300, and have the dimensional precision and absence of interstitial defects characteristic of photolithographic processing, compatible with positional matching to silicon electronics readouts. The open channel areal fraction and detection efficiency may exceed 90% on plates up to 300 mm in diameter. The resulting silicon substrates can be converted entirely to amorphous quartz (qMCP). The strip resistance and secondary emission are developed by controlled depositions of thin films, at temperatures up to 1200 deg. C, also compatible with high-temperature brazing, and can be essentially hydrogen, water and radionuclide-free. Novel secondary emitters and cesiated photocathodes can be high-temperature deposited or nucleated in the channels or the first strike surface. Results on resistivity, secondary emission and gain are presented

  16. High precision refractometry based on Fresnel diffraction from phase plates.

    Science.gov (United States)

    Tavassoly, M Taghi; Naraghi, Roxana Rezvani; Nahal, Arashmid; Hassani, Khosrow

    2012-05-01

    When a transparent plane-parallel plate is illuminated at a boundary region by a monochromatic parallel beam of light, Fresnel diffraction occurs because of the abrupt change in phase imposed by the finite change in refractive index at the plate boundary. The visibility of the diffraction fringes varies periodically with changes in incident angle. The visibility period depends on the plate thickness and the refractive indices of the plate and the surrounding medium. Plotting the phase change versus incident angle or counting the visibility repetition in an incident-angle interval provides, for a given plate thickness, the refractive index of the plate very accurately. It is shown here that the refractive index of a plate can be determined without knowing the plate thickness. Therefore, the technique can be utilized for measuring plate thickness with high precision. In addition, by installing a plate with known refractive index in a rectangular cell filled with a liquid and following the described procedures, the refractive index of the liquid is obtained. The technique is applied to measure the refractive indices of a glass slide, distilled water, and ethanol. The potential and merits of the technique are also discussed.

  17. Water

    Science.gov (United States)

    ... www.girlshealth.gov/ Home Nutrition Nutrition basics Water Water Did you know that water makes up more ... to drink more water Other drinks How much water do you need? top Water is very important, ...

  18. A heat exchanger provided with plates

    International Nuclear Information System (INIS)

    Chaix, J.E.; Fajeau, Maurice; Chlique, Bernard.

    1976-01-01

    The invention relates to a heat exchanger of the plate type, in which two fluids exchange calories through parallel metal plates, delimiting spaces separated from each other in which two fluids respectively flow without direct contact between them. The invention particularly applies in the case where one of the two fluids is water under pressure or else a circulating liquid metal, specially sodium, used in the system of a pressurised water or fast neutron reactor, the second fluid being water to be vaporised in the exchanger by the calories supplied by the first fluid. The arrangement is designed to give minimum bulk, particularly enabling the exchanger to be housed in the area between the core of a nuclear reactor and a casing or outer vessel, or else in an external sealed containment, with a view to recovering with the best efficiency the heat acquired by a coolant flowing through the core [fr

  19. Anti-microbial efficacy of green tea and chlorhexidine mouth rinses against Streptococcus mutans, Lactobacilli spp. and Candida albicans in children with severe early childhood caries: A randomized clinical study

    Directory of Open Access Journals (Sweden)

    Ann Thomas

    2016-01-01

    Full Text Available Introduction: Green tea is a beverage which is consumed worldwide and is reported to have anti-cariogenic effect. So, if it was as effective as chlorhexidine (CHX mouth rinse against cariogenic microbes it could be considered a natural, economical alternative. The purpose of this study was to evaluate and compare the anti-microbial efficacy of 0.5% green tea and 0.2% CHX mouth rinses against Streptococcus Mutans, Lactobacilli spp. and Candida Albicans. Materials and Methods: 30 children aged 4-6 years with S-ECC (based ondefs score were selected. Children were divided randomly into 2 equal groups and were asked to rinse with the prescribed mouth rinse once daily for 2 weeks after breakfast under supervision. A base-line and post rinsing non-stimulated whole salivary sample (2 ml was collected and tested for the number of colony forming units. The data was statistically analyzed using SPSS v16.0 software with one-way ANOVA and Tukey′sPOSTHOC test. Results: A statistically significant fall in colony count was found with both the mouth rinses in Streptococcus Mutans (P < 0.001, P < 0.001 and lactobacilli (P < 0.001, P < 0.001 but not against Candida albicans (P = 0.264, P = 0.264. Against Streptococcus Mutans, green tea mouth rinse was found to be significantly better than CHX mouth rinse (P = 0.005. Against lactobacilli spp, CHX mouth rinse was significantly better than green tea mouth rinse (P < 0.001. Conclusion: Green tea mouth rinse can be considered safe, economical and used without much concern. However, further studies are recommended.

  20. Effect of ferric sulfate contamination on the bonding effectiveness of etch-and-rinse and self-etch adhesives to superficial dentin

    OpenAIRE

    Shahram Farzin Ebrahimi; Niloofar Shadman; Arezoo Abrishami

    2013-01-01

    Aim: This study investigated the effect of one hemostatic agent on the shear bond strength of self-etch and etch-and-rinse adhesive systems. Materials and Methods: Sixty extracted third molars were selected. After preparing a flat surface of superficial dentin, they were randomly divided into six groups. Adhesives were Tetric N-Bond, AdheSE, and AdheSE One F. Before applying adhesives, surfaces were contaminated with ViscoStat for 60 s in three groups and rinsed. Then composite were attached ...

  1. Corrosion of Cast Iron Mill Plates in Wet Grinding

    Directory of Open Access Journals (Sweden)

    Anthony ANDREWS

    2010-12-01

    Full Text Available Corrosion studies were carried out on two different maize grinding plates. Maize was soaked in water for three days and the water decanted and used as electrolyte. Mass loss and pH measurements were carried out every 3 days for 15-day period. Results show that, for each plate, mass loss and pH increased with exposure time. Corrosion rates determined from mass loss data was found to be strongly dependent on pH. The observed behaviour may be explained in terms of the chemical composition and/or microstructures of the plates. Results are briefly discussed in terms of the contribution of corrosion to wear.

  2. Plate Full of Color

    Centers for Disease Control (CDC) Podcasts

    The Eagle Books are a series of four books that are brought to life by wise animal characters - Mr. Eagle, Miss Rabbit, and Coyote - who engage Rain That Dances and his young friends in the joy of physical activity, eating healthy foods, and learning from their elders about health and diabetes prevention. Plate Full of Color teaches the value of eating a variety of colorful and healthy foods.

  3. Plate removal following orthognathic surgery.

    Science.gov (United States)

    Little, Mhairi; Langford, Richard Julian; Bhanji, Adam; Farr, David

    2015-11-01

    The objectives of this study are to determine the removal rates of orthognathic plates used during orthognathic surgery at James Cook University Hospital and describe the reasons for plate removal. 202 consecutive orthognathic cases were identified between July 2004 and July 2012. Demographics and procedure details were collected for these patients. Patients from this group who returned to theatre for plate removal between July 2004 and November 2012 were identified and their notes were analysed for data including reason for plate removal, age, smoking status, sex and time to plate removal. 3.2% of plates were removed with proportionally more plates removed from the mandible than the maxilla. 10.4% of patients required removal of one or more plate. Most plates were removed within the first post-operative year. The commonest reasons for plate removal were plate exposure and infection. The plate removal rates in our study are comparable to those seen in the literature. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  4. Plate Tearing by a Cone

    DEFF Research Database (Denmark)

    Simonsen, Bo Cerup

    1997-01-01

    The present paper is concerned with steady-state plate tearing by a cone. This is a scenario where a cone is forced through a ductile metal plate with a constant lateral tip penetration in a motion in the plane of the plate. The considered process could be an idealisaton of the damage, which...... as for the out-of-plane reaction force....

  5. Normal and abnormal growth plate

    International Nuclear Information System (INIS)

    Kumar, R.; Madewell, J.E.; Swischuk, L.E.

    1987-01-01

    Skeletal growth is a dynamic process. A knowledge of the structure and function of the normal growth plate is essential in order to understand the pathophysiology of abnormal skeletal growth in various diseases. In this well-illustrated article, the authors provide a radiographic classification of abnormal growth plates and discuss mechanisms that lead to growth plate abnormalities

  6. Advantageous technology for treatment of laundry waters

    International Nuclear Information System (INIS)

    Karlin, Y.; Gorbachev, D.; Volkov, A.; Barinov, A.

    2001-01-01

    In this paper, based on preliminary experimental studies, an improved scheme for cleaning of laundry water is offered which allows reuse of water and components of laundry solutions and produces low amounts of secondary radioactive waste. The principal feature of the proposed process is that waste water from rinsing (60-80% of the total volume) is processed by hyperfiltration, but waste water from the laundry (20-40% of the total volume) is treated by ultrafiltration. Concentrates after reverse osmosis desalination of waste liquids (after rinsing) contain a majority of laundry waste components, since a hyperfiltration membrane efficiently retains salts and surfactant molecules. Desalinated water (permeate) after hyperfiltration is reused, further reducing the volume of liquid wastes. (author)

  7. Quantification of Campylobacter spp. in chicken rinse samples by using flotation prior to real-time PCR

    DEFF Research Database (Denmark)

    Wolffs, Petra; Norling, Börje; Hoorfar, Jeffrey

    2005-01-01

    Real-time PCR is fast, sensitive, specific, and can deliver quantitative data; however, two disadvantages are that this technology is sensitive to inhibition by food and that it does not distinguish between DNA originating from viable, viable nonculturable (VNC), and dead cells. For this reason......, real-time PCR has been combined with a novel discontinuous buoyant density gradient method, called flotation, in order to allow detection of only viable and VNC cells of thermotolerant campylobacters in chicken rinse samples. Studying the buoyant densities of different Campylobacter spp. showed...... enrichment and amounts as low as 2.6 X 10(3) CFU/ml could be quantified. Furthermore, subjecting viable cells and dead cells to flotation showed that viable cells were recovered after flotation treatment but that dead cells and/or their DNA was not detected. Also, when samples containing VNC cells mixed...

  8. Study of uranium plating measurement

    International Nuclear Information System (INIS)

    Lin Jufang; Wen Zhongwei; Wang Mei; Wang Dalun; Liu Rong; Jiang Li; Lu Xinxin

    2007-06-01

    In neutron physics experiments, the measurement for plate-thickness of uranium can directly affect uncertainties of experiment results. To measure the plate-thickness of transform target (enriched uranium plating and depleted uranium plating), the back to back ionization chamber, small solid angle device and Au-Si surface barrier semi-conductor, were used in the experiment study. Also, the uncertainties in the experiment were analyzed. Because the inhomo-geneous of uranium lay of plate can quantitively affect the result, the homogeneity of uranium lay is checked, the experiment result reflects the homogeneity of uranium lay is good. (authors)

  9. Cooking rice in excess water reduces both arsenic and enriched vitamins in the cooked grain.

    Science.gov (United States)

    Gray, Patrick J; Conklin, Sean D; Todorov, Todor I; Kasko, Sasha M

    2016-01-01

    This paper reports the effects of rinsing rice and cooking it in variable amounts of water on total arsenic, inorganic arsenic, iron, cadmium, manganese, folate, thiamin and niacin in the cooked grain. We prepared multiple rice varietals both rinsed and unrinsed and with varying amounts of cooking water. Rinsing rice before cooking has a minimal effect on the arsenic (As) content of the cooked grain, but washes enriched iron, folate, thiamin and niacin from polished and parboiled rice. Cooking rice in excess water efficiently reduces the amount of As in the cooked grain. Excess water cooking reduces average inorganic As by 40% from long grain polished, 60% from parboiled and 50% from brown rice. Iron, folate, niacin and thiamin are reduced by 50-70% for enriched polished and parboiled rice, but significantly less so for brown rice, which is not enriched.

  10. Efficacy of a Rinse Containing Sea Salt and Lysozyme on Biofilm and Gingival Health in a Group of Young Adults: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Jeyaraj Hoover

    2017-01-01

    Full Text Available Objectives. To evaluate new mouth rinse containing sea salt, xylitol, and lysozyme on biofilm formation and gingival health in a group of young adults. Methods. The subjects were divided into two groups of 15 subjects each: control (A and experimental group (B. The Turesky modification of Quigley-Hein plaque index was used to evaluate plaque scores while the presence or absence of gingival bleeding was used to determine gingival health. Measurements were done at baseline and at the end of the one-month trial period by one blinded examiner on six representative teeth. Group (A maintained standardized oral health practices for the duration of the experiment. In addition, group (B rinsed with a tablespoon of the provided sea salt mouth rinse for 30 seconds once in the morning and at night. After the 30-day trial period, subjects in both groups were reassessed as per baseline. Results. There were no statistically significant differences in the overall reduction from baseline in the mean plaque and gingivitis scores on all surfaces or on individual surfaces. Conclusion. Within the limitations of the study, rinsing with sea salt for thirty days did not affect the gingival and plaque scores in a group of young adults.

  11. The effect of a daily application of a 0.05% chlorhexidine oral rinse solution on the incidence of aspiration pneumonia in nursing home residents: a multicenter study.

    NARCIS (Netherlands)

    Hollaar, V.R.Y.; Putten, G.J. van der; Maarel-Wierink, C.D. van der; Bronkhorst, E.M.; Swart, B.J.M. de; Creugers, N.H.J.

    2017-01-01

    BACKGROUND: Dysphagia and potential respiratory pathogens in the oral biofilm are risk factors for aspiration pneumonia in nursing home residents. The aim of the study was to examine if the daily application of 0.05% chlorhexidine oral rinse solution is effective in reducing the incidence of

  12. A Quantitative Risk Assessment of the Skin Sensitization Induction Potential of the Kathon CG Preservative in Rinse-off and Leave-on Personal Care and Cosmetic Products.

    Science.gov (United States)

    Towle, Kevin M; Drechsel, Derek A; Warshaw, Erin M; Fung, Ernest S; Novick, Rachel M; Paustenbach, Dennis J; Monnot, Andrew D

    2018-03-22

    Kathon CG is a commonly used cosmetic-grade preservative that contains active ingredients methylchloroisothiazolinone (MCI) and methylisothiazolinone (MI). The aim of the study was to perform a skin sensitization induction risk assessment of daily exposure to Kathon CG after use of various personal care and cosmetic products. We calculated an estimated daily consumer exposure level for rinse-off and leave-on products using the amount of product applied per application, number of applications per day, a retention factor, the MCI/MI concentration, and body surface area values. We assumed that the products contained the maximum recommended safe concentration of MCI/MI: 15 ppm in rinse-off products and 7.5 ppm in leave-on products. We compared estimated consumer exposure levels with the no expected sensitization induction level for MCI/MI and applied sensitization assessment factors to calculate product-specific margins of safety (MOSs). The MOSs for rinse-off products ranged from 5 to 63, whereas the MOSs for leave-on products ranged from 0.03 to 1.49. Overall, our results provide evidence that some leave-on products containing the maximum recommended safe concentration of Kathon CG may increase the risk of sensitization induction due to exposure to MCI/MI. In contrast, rinse-off products were not associated with a potential increased risk of skin sensitization induction.

  13. A modified rinsing method for the determination of the S, W-S and D + U fraction of protein and starch in feedstuff within the in situ technique

    NARCIS (Netherlands)

    Jonge, de L.H.; Laar, van H.; Hendriks, W.H.; Dijkstra, J.

    2013-01-01

    A modified rinsing method for the in situ technique was developed to separate, isolate and characterise the soluble (S), the insoluble washout (W–S) and the non-washout fractions (D1U) within one procedure. For non-incubated bags ( t50 h), this method was compared with the conventional, Combined

  14. Fuel cell end plate structure

    Science.gov (United States)

    Guthrie, Robin J.; Katz, Murray; Schroll, Craig R.

    1991-04-23

    The end plates (16) of a fuel cell stack (12) are formed of a thin membrane. Pressure plates (20) exert compressive load through insulation layers (22, 26) to the membrane. Electrical contact between the end plates (16) and electrodes (50, 58) is maintained without deleterious making and breaking of electrical contacts during thermal transients. The thin end plate (16) under compressive load will not distort with a temperature difference across its thickness. Pressure plate (20) experiences a low thermal transient because it is insulated from the cell. The impact on the end plate of any slight deflection created in the pressure plate by temperature difference is minimized by the resilient pressure pad, in the form of insulation, therebetween.

  15. A comparison of dioctahedral smectite and iodine glycerin cream with topical mouth rinse in treatment of chemotherapy induced oral mucositis: a pilot study.

    Science.gov (United States)

    Lin, Jin-Xiang; Fan, Zu-Yan; Lin, Qu; Wu, Dong-Hao; Wu, Xiang-Yuan; Chen, Yan-Ru; Fang, Heng-Ying; Wu, Dong-Bing; Wen, Jing-Yun; Dong, Min; Ma, Xiao-Kun; Wan, Xiang-Bo

    2015-04-01

    To compare the efficacy of dioctahedral smectite and iodine glycerin (DSIG) cream with topical mouth rinse (composed of saline, gentamicin and Vitamin B12) in treatment of chemotherapy induced oral mucositis (OM). A total of 130 intensive chemotherapy or stem cells transplantation induced OM patients were recruited. Among these patients, 67 patients received topical mouth rinse and 63 patients received DSIG cream treatment. The OM would be treated on the OM appearance and sustained for 5 days. OM severity was measured daily using The American Oncology Nursing Society recommended Oral Assessment Guideline (OAG) score system. Compared with topical mouth rinse treatment, a significant lower OAG score was observed in DSIG cream treated patients. Specifically, the OAG scores were respectively 12.1 ± 1.1, 12.0 ± 1.2, 11.3 ± 1.3 and 10.4 ± 1.3 from day 2 to day 5 in topical mouth rinse treatment subgroup. Correspondingly, the OAG scores were respectively 10.2 ± 1.0, 9.3 ± 0.9, 8.5 ± 0.6 and 8.0 ± 0.2 for DSIG cream treatment subset (all P < 0.05). Importantly, compared with topical mouth rinse treatment, the DSIG cream significantly shortened OM repair time (4.68 ± 0.98 vs. 8.76 ± 1.80 days, P < 0.001). After 5 days treatment, 54 patients (85.7%) obtained complete regression with an OAG score ≤8, and 7 patients (11.1%) had partial regression with an OAG score of 9-10 in DSIG cream treatment subgroup. However, only 2 patients (3.0%) obtained completed regression and 32 patients (47.8%) had partial regression in topical mouth rinse treatment cohort. Moreover, no serious side-effect was observed in both cohorts. Compared with topical mouth rinse, DSIG cream significantly lowered the OAG score and shortened OM duration. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. [Conventional plate osteosynthesis].

    Science.gov (United States)

    Klaue, K

    2010-02-01

    Consolidation of bone is an essential clinical problem when treating fractures, fixing osteotomies and fusing joints. In most cases, the means of fixation are plates and screws. The goal is functional postoperative therapy by moving the adjacent joints and thus avoiding the deleterious disadvantages of long-lasting articular immobilization. Pre-operative planning, surgical approach, a good understanding of the precise mechanics of the structure and the biological answer for the various tissues are prerequisites of successful osteosynthesis. The choice of implants and the application of their versatility, as well as their adaptation to individual cases are the key to good results.

  17. Plate Full of Color

    Centers for Disease Control (CDC) Podcasts

    2008-08-04

    The Eagle Books are a series of four books that are brought to life by wise animal characters - Mr. Eagle, Miss Rabbit, and Coyote - who engage Rain That Dances and his young friends in the joy of physical activity, eating healthy foods, and learning from their elders about health and diabetes prevention. Plate Full of Color teaches the value of eating a variety of colorful and healthy foods.  Created: 8/4/2008 by National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP).   Date Released: 8/5/2008.

  18. Plate tectonics and planetary habitability: current status and future challenges.

    Science.gov (United States)

    Korenaga, Jun

    2012-07-01

    Plate tectonics is one of the major factors affecting the potential habitability of a terrestrial planet. The physics of plate tectonics is, however, still far from being complete, leading to considerable uncertainty when discussing planetary habitability. Here, I summarize recent developments on the evolution of plate tectonics on Earth, which suggest a radically new view on Earth dynamics: convection in the mantle has been speeding up despite its secular cooling, and the operation of plate tectonics has been facilitated throughout Earth's history by the gradual subduction of water into an initially dry mantle. The role of plate tectonics in planetary habitability through its influence on atmospheric evolution is still difficult to quantify, and, to this end, it will be vital to better understand a coupled core-mantle-atmosphere system in the context of solar system evolution. © 2012 New York Academy of Sciences.

  19. Development of a high-throughput method based on thin-film microextraction using a 96-well plate system with a cork coating for the extraction of emerging contaminants in river water samples.

    Science.gov (United States)

    Morés, Lucas; Dias, Adriana Neves; Carasek, Eduardo

    2018-02-01

    In this study, a new method was developed in which a biosorbent material is used as the extractor phase in conjunction with a recently described sample preparation technique called thin-film microextraction and a 96-well plate system. The method was applied for the determination of emerging contaminants, such as 3-(4-methylbenzylidene) camphor, ethylparaben, triclocarban, and bisphenol A in water samples. The separation and detection of the analytes were performed by high-performance liquid chromatography with diode array detection. These contaminants are considered hazardous to human health and other living beings. Thus, the development of an analytical method to determine these compounds is of great interest. The extraction parameters were evaluated using multivariate and univariate optimization techniques. The optimum conditions for the method were 3 h of extraction time, 20 min of desorption with 300 μL of acetonitrile and methanol (50:50, v/v), and the addition of 5% w/v sodium chloride to the sample. The analytical figures of merit showed good results with linear correlation coefficients higher than 0.99, relative recoveries of 72-125%, interday precision (n = 3) of 4-18%, and intraday precision (n = 9) of 1-21%. The limit of detection was 0.3-5.5 μg/L, and the limit of quantification was 0.8-15 μg/L. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Plating on difficult-to-plate metals: what's new

    International Nuclear Information System (INIS)

    Wiesner, H.J.

    1980-01-01

    Some of the changes since 1970 in procedures for plating on such materials as titanium, molybdenum, silicon, aluminum, and gallium arsenide are summarized. While basic procedures for plating some of these materials were developed as many as 30 to 40 years ago, changes in the end uses of the plated products have necessitated new plating processes. In some cases, vacuum techniques - such as ion bombardment, ion implantation, and vacuum metallization - have been introduced to improve the adhesion of electrodeposits. In other cases, these techniques have been used to deposit materials upon which electrodeposits are required

  1. Fabrication procedures for HFIR control plates

    Energy Technology Data Exchange (ETDEWEB)

    Bowden, G.A.; Hicks, G.R.; Knight, R.W.

    1984-10-01

    The HFIR control system uses Alclad cylindrically shaped components, which have regions containing 31 vol % Eu/sub 2/O/sub 3/ and 38 vol % Ta, respectively. Exacting control of the water passage between these components and adjacent reactor parts is mandatory, and precise dimensional control of the finished products is required. This report describes the procedures developed for manufacturing outer control plates and inner control cylinders. Results are cited which demonstrate that circular-shaped outer control plates can be produced with less than 0.025-in. variation from the specified 9.300-in. radius in any region of the plate. Other results show that, by the exercise of careful control, inner control, inner control plates can be welded into cylindrical geometry with diametrical variations held to less than +- 0.010 in. of the intended 17.846-in. average diam. The cylinders can then be explosively sized, while under compression, with diametric variations of less than 0.005 in. while controlling roundness variations to less than 0.030 in. from the specified 17.842-in. finished diam.

  2. Fabrication procedures for HFIR control plates

    International Nuclear Information System (INIS)

    Bowden, G.A.; Hicks, G.R.; Knight, R.W.

    1984-10-01

    The HFIR control system uses Alclad cylindrically shaped components, which have regions containing 31 vol % Eu 2 O 3 and 38 vol % Ta, respectively. Exacting control of the water passage between these components and adjacent reactor parts is mandatory, and precise dimensional control of the finished products is required. This report describes the procedures developed for manufacturing outer control plates and inner control cylinders. Results are cited which demonstrate that circular-shaped outer control plates can be produced with less than 0.025-in. variation from the specified 9.300-in. radius in any region of the plate. Other results show that, by the exercise of careful control, inner control, inner control plates can be welded into cylindrical geometry with diametrical variations held to less than +- 0.010 in. of the intended 17.846-in. average diam. The cylinders can then be explosively sized, while under compression, with diametric variations of less than 0.005 in. while controlling roundness variations to less than 0.030 in. from the specified 17.842-in. finished diam

  3. Plate Tearing by a Cone

    DEFF Research Database (Denmark)

    Simonsen, Bo Cerup

    1998-01-01

    The present paper is concerned with steady-state plate tearing by a cone. This is a scenario where a cone is forced through a ductile metal plate with a constant lateral tip penetration in a motion in the plane of the plate. The considered process could be an idealisation of the damage, which...... as for the out-of-plane reaction force. (C) 1998 Elsevier Science Ltd. All rights reserved....

  4. Looking for Plate Tectonics in all the wrong fluids

    Science.gov (United States)

    Davaille, Anne

    2017-04-01

    Ever since the theory of Plate Tectonics in the 1960's, the dream of the geomodeler has been to generate plate tectonics self-consistently from thermal convection in the laboratory. By selfconsistenly, I mean that the configuration of the plate boundaries is in no way specified a priori, so that the plates develop and are wholly consumed without intervention from the modeler. The reciepe is simple : put a well-chosen fluid in a fishtank heated from below and cooled from above, wait and see. But the « well-chosen » is the difficult part... and the interesting one. Plate tectonics is occuring on Earth because of the characteristics of the lithosphere rheology. The latter are complex to estimate as they depend on temperature, pressure, phase, water content, chemistry, strain rate, memory and scale. As a result, the ingredients necessary for plate tectonics are still debated, and it would be useful to find an analog fluid who could reproduce plate tectonics in the laboratory. I have therefore spent the last 25 years to try out fluids, and I shall present a number of failures to generate plate tectonics using polymers, colloids, ketchup, milk, chocolate, sugar, oils. To understand why they failed is important to narrow down the « well-chosen » fluid.

  5. Sound Scattering by a Flexible Plate Embedded on Free Surface

    Directory of Open Access Journals (Sweden)

    Eldad J. Avital

    2012-01-01

    Full Text Available Sound wave scattering by a flexible plate embedded on water surface is considered. Linear acoustics and plate elasticity are assumed. The aim is to assess the effect of the plate’s flexibility on sound scattering and the potential in using that flexibility for this purpose. A combined sound-structure solution is used, which is based on a Fourier transform of the sound field and a finite-difference numerical-solution of the plate’s dynamics. The solution is implemented for a circular plate subject to a perpendicular incoming monochromatic sound wave. A very good agreement is achieved with a finite-difference solution of the sound field. It is shown that the flexibility of the plate dampens its scattered sound wave regardless of the type of the plate’s edge support. A hole in the plate is shown to further scatter the sound wave to form maxima in the near sound field. It is suggested that applying an external oscillatory pressure on the plate can reduce significantly and even eliminate its scattered wave, thus making the plate close to acoustically invisible. A uniformly distributed external pressure is found capable of achieving that aim as long as the plate is free edged or is not highly acoustically noncompact.

  6. Electric alignment of plate shaped clay aggregates in oils

    Directory of Open Access Journals (Sweden)

    Rene Christian Castberg

    2016-01-01

    Full Text Available We experimentally investigate the rotation of plate shaped aggregates of clay mineral particles immersed in silicone oil. The rotation is induced by an external electric field. The rotation time is measured as a function of the following parameters: electric field strength, the plate geometry (length and width and the dielectric properties of the plates. We find that the plates always align with their longest axis parallel to the direction of the electric field (E, independently of the arrangement of individual clay−2 mineral particles within the plate. The rotation time is found to scale as E and is proportional to the viscosity (μ, which coincides well with a model that describes orientation of dipoles in electric fields. As the length of the plate is increased we quantify a difference between the longitudinal and transverse polarisability. Finally, we show that moist plates align faster. We attribute this to the change of the dielectric properties of the plate due to the presence of water.

  7. Scintillator plate calorimetry

    International Nuclear Information System (INIS)

    Price, L.E.

    1990-01-01

    Calorimetry using scintillator plates or tiles alternated with sheets of (usually heavy) passive absorber has been proven over multiple generations of collider detectors. Recent detectors including UA1, CDF, and ZEUS have shown good results from such calorimeters. The advantages offered by scintillator calorimetry for the SSC environment, in particular, are speed (<10 nsec), excellent energy resolution, low noise, and ease of achieving compensation and hence linearity. On the negative side of the ledger can be placed the historical sensitivity of plastic scintillators to radiation damage, the possibility of nonuniform response because of light attenuation, and the presence of cracks for light collection via wavelength shifting plastic (traditionally in sheet form). This approach to calorimetry is being investigated for SSC use by a collaboration of Ames Laboratory/Iowa State University, Argonne National Laboratory, Bicron Corporation, Florida State University, Louisiana State University, University of Mississippi, Oak Ridge National Laboratory, Virginia Polytechnic Institute and State University, Westinghouse Electric Corporation, and University of Wisconsin

  8. Reviewing metallic PEMFC bipolar plates

    Energy Technology Data Exchange (ETDEWEB)

    Wang, H.; Turner, J.A. [National Renewable Energy Laboratory, Golden, CO (United States)

    2010-08-15

    A bipolar plate is one of the most important components in a polymer exchange membrane fuel cell (PEMFC) stack and has multiple functions. Metallic bipolar plate candidates have advantages over composite rivals in excellent electrical and thermal conductivity, good mechanical strength, high chemical stability, very wide alloy choices, low cost and, most importantly, existing pathways for high-volume, high-speed mass production. The challenges with metallic bipolar plates are the higher contact resistance and possible corrosion products, which may contaminate the membrane electrode assembly. This review evaluates the candidate metallic and coating materials for bipolar plates and gives the perspective of the research trends. (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  9. Modeling particulate removal in plate-plate and wire-plate electrostatic precipitators

    Directory of Open Access Journals (Sweden)

    S Ramechecandane

    2016-09-01

    Full Text Available The present study is concerned with the modeling of electrically charged particles in a model plate-plate and a single wire-plate electrostatic precipitator (ESP. The particle concentration distributions for both a plate-plate and a wire-plate ESP are calculated using a modified drift flux model. Numerical investigations are performed using the modified drift flux model for particle number concentration, in addition to the RNG k - ε model for the mean turbulent flow field and the Poisson equation for the electric field. The proposed model and the outlined methodology for coupling the flow field, electric field, charging kinetics and particle concentration is applied to two model precipitators that are truly representative of a wide class of commercialized ESPs. The present investigation is quite different from the earlier studies as it does not make assumptions like a homogeneous electric field or an infinite turbulent diffusivity. The electric field calculated is a strong function of position and controls the migration velocity of particles. Hence, the proposed model can be implemented in a flow solver to obtain a full-fledged solution for any kind of ESP with no limitations on the particle number concentration, as encountered in a Lagrangian approach. The effect of turbulent diffusivity on particle number concentration in a plate-plate ESP is investigated in detail and the results obtained are compared with available experimental data. Similarly, the effect of particle size/diameter and applied electric potential on the accumulative collection performance in the case of a wire-plate ESP is studied and the results obtained are compared with available numerical data. The numerical results obtained using the modified drift flux model for both the plate-plate and wire-plate ESP are in close agreement with available experimental and numerical data.

  10. Fuel plate stability experiments and analysis for the Advanced Neutron Source

    International Nuclear Information System (INIS)

    Swinson, W.F.; Battiste, R.L.; Luttrell, C.R.; Yahr, G.T.

    1992-01-01

    The planned Advanced Neutron Source (ANS) and several existing reactors use closely spaced arrays of involute shaped fuel-plates which are cooled by water flowing through the channels between the plates. There is concern that at certain coolant flow velocities adjacent plates may deflect and touch, with resulting failure of the plates. Experiments have been conducted at the Oak Ridge National Laboratory to examine this potential phenomenon. Results of the experiments and comparison with analytical predictions are reported in this paper. The tests were conducted using full scale epoxy plate models of the aluminum/uranium silicide ANS involute shaped fuel plates. Use of epoxy plates and model theory allowed lower flow velocities and pressures to explore the potential failure mechanism. Plate deflections and channel pressures as function of the flow velocity are examined. Comparisons with mathematical models are noted. 12 refs

  11. Fuel plate stability experiments and analysis for the Advanced Neutron Source

    International Nuclear Information System (INIS)

    Swinson, W.F.; Battiste, R.L.; Luttrell, C.R.; Yahr, G.T.

    1993-05-01

    The planned reactor for the Advanced Neutron Source (ANS) will use closely spaced arrays of involute-shaped fuel plates that will be cooled by water flowing through the channels between the plates. There is concern that at certain coolant flow velocities, adjacent plates may deflect and touch, with resulting failure of the plates. Experiments have been conducted at the Oak Ridge National Laboratory to examine this potential phenomenon. Results of the experiments and comparison with analytical predictions are reported. The tests were conducted using full-scale epoxy plate models of the aluminum/uranium silicide ANS involute-shaped fuel plates. Use of epoxy plates and model theory allowed lower flow velocities and pressures to explore the potential failure mechanism. Plate deflections and channel pressures as functions of the flow velocity are examined. Comparisons with mathematical models are noted

  12. 2-Mercaptobenzimidazole, 2-Mercaptobenzothiazole, and Thioglycolic Acid in an Electroless Nickel-Plating Bath

    Directory of Open Access Journals (Sweden)

    Ahmet Ozan Gezerman

    2015-01-01

    Full Text Available The use of three different materials, 2-mercaptobenzimidazole, 2-mercaptobenzothiazole, and thioglycolic acid, was investigated to improve the performance of electroless nickel-plating baths. By changing the concentrations of these materials, sample plates were coated. Optical microscope images were obtained by selecting representative coated plates. From the results of the investigations, the effects of these materials on electroless nickel plating were observed, and the most appropriate amounts of these materials for nickel plating were determined. Moreover, the nickel plating speed observed with the bath solution containing 2-mercaptobenzimidazole, 2-mercaptobenzothiazole, and thioglycolic acid is higher than that in the case of traditional electroless plating baths, but the nickel consumption amount in the former case is lower. In order to minimize the waste water generated from electroless nickel-plating baths, we determined the lowest amounts of the chemicals that can be used for the concentrations reported in the literature.

  13. Rough horizontal plates: heat transfer and hysteresis

    Energy Technology Data Exchange (ETDEWEB)

    Tisserand, J-C; Gasteuil, Y; Pabiou, H; Castaing, B; Chilla, F [Universite de Lyon, ENS Lyon, CNRS, 46 Allee d' ltalie, 69364 Lyon Cedex 7 (France); Creyssels, M [LMFA, CNRS, Ecole Centrale Lyon, 69134 Ecully Cedex (France); Gibert, M, E-mail: mathieu.creyssels@ec-lyon.fr [Also at MPI-DS (LFPN) Gottingen (Germany)

    2011-12-22

    To investigate the influence of a rough-wall boundary layer on turbulent heat transport, an experiment of high-Rayleigh convection in water is carried out in a Rayleigh-Benard cell with a rough lower plate and a smooth upper plate. A transition in the heat transport is observed when the thermal boundary layer thickness becomes comparable to or smaller than the roughness height. Besides, at larger Rayleigh numbers than the threshold value, heat transport is found to be increased up to 60%. This enhancement cannot be explained simply by an increase in the contact area of the rough surface since the contact area is increased only by a factor of 40%. Finally, a simple model is proposed to explain the enhanced heat transport.

  14. Electric arc, water jet cutting of metals

    International Nuclear Information System (INIS)

    Bruening, D.

    1991-01-01

    For thermal dismantling and cutting of metallic components, as electric arc, water jet cutting method was developed that can be used for underwater cutting work up to a depth of 20 m. Short-circuiting of a continuously fed electrode wire in contact with the metal generates an electric arc which induces partial melting of the metal, and the water jet surrounding the wire rinses away the molten material, thus making a continuous kerf in the material. The method was also tested and modified to allow larger area, surface cutting and removal of metallic surface coatings. This is achieved by melting parts of the surface with the electric arc and subsequent rinsing by the water jet. The cutting and melting depth for surface removal can be accurately controlled by the operating parameters chosen. (orig./DG) [de

  15. Public health risk status of the water supply frame work at Kwame ...

    African Journals Online (AJOL)

    user

    3Biochemistry Division, Chemical Sciences Department, Faculty of Science, ... physicochemical and microbial quality of the tap water differed significantly ... the existing plumbing materials and codes, it is not ... HCl, rinsed with distilled water until acid free. ... containing sample number, date, time and kept in the laboratory.

  16. Create Your Plate

    Medline Plus

    Full Text Available ... Carbohydrate Counting Make Your Carbs Count Glycemic Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type ... and vinaigrettes. To complete your meal, add a low-calorie drink like water, unsweetened tea or coffee. ...

  17. Laterally Loaded Nail-Plates

    DEFF Research Database (Denmark)

    Nielsen, Jacob; Rathkjen, Arne

    Load-displacement curves from about 200 short-term and laterally loaded nail-plate joints are analysed. The nail-plates are from Gang-Nail Systems, type GNA 20 S. The test specimens and the measuring systems are described. The tests are divided into 32 different series. The influence of the number...

  18. MyPlate Food Guide

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español MyPlate Food Guide KidsHealth / For Teens / MyPlate Food Guide What's ... and other sugary drinks. Avoid large portions . Five Food Groups Different food groups have different nutrients and ...

  19. Scintillating plate calorimeter optical design

    International Nuclear Information System (INIS)

    McNeil, R.; Fazely, A.; Gunasingha, R.; Imlay, R.; Lim, J.

    1990-01-01

    A major technical challenge facing the builder of a general purpose detector for the SSC is to achieve an optimum design for the calorimeter. Because of its fast response and good energy resolution, scintillating plate sampling calorimeters should be considered as a possible technology option. The work of the Scintillating Plate Calorimeter Collaboration is focused on compensating plate calorimeters. Based on experimental and simulation studies, it is expected that a sampling calorimeter with alternating layers of high-Z absorber (Pb, W, DU, etc.) and plastic scintillator can be made compensating (e/h = 1.00) by suitable choice of the ratio of absorber/scintillator thickness. Two conceptual designs have been pursued by this subsystem collaboration. One is based on lead as the absorber, with read/out of the scintillator plates via wavelength shifter fibers. The other design is based on depleted uranium as the absorber with wavelength shifter (WLS) plate readout. Progress on designs for the optical readout of a compensating scintillator plate calorimeter are presented. These designs include readout of the scintillator plates via wavelength shifter plates or fiber readout. Results from radiation damage studies of the optical components are presented

  20. Effect of Aloe vera, chlorine dioxide, and chlorhexidine mouth rinses on plaque and gingivitis: A randomized controlled trial

    Science.gov (United States)

    Yeturu, Sravan Kumar; Acharya, Shashidhar; Urala, Arun Sreenivas; Pentapati, Kalyana Chakravarthy

    2015-01-01

    Objective To evaluate the effect of Aloe vera, chlorine dioxide, and chlorhexidine mouth rinses on plaque and gingivitis in orthodontic treatment. Materials and methods A randomized single-center, single-blind, parallel group, controlled trial was conducted among 90 subjects undergoing fixed orthodontic treatment. The subjects were randomly divided into one of the three study groups (Aloe vera, chlorhexidine, chlorine dioxide). Plaque and gingivitis were assessed using modified Silness and Loe Plaque Index and Gingival Index at baseline and at follow-up after 15 days. Paired t-test and ANOVA with post hoc Dunnett test were used. A p-value of <0.05 was considered statistically significant. Results A total of 85 participants completed the study; among them, 40 were male and 45 were female. There was significant reduction in mean plaque and gingival scores in all the 3 groups at follow-up when compared to baseline. A significantly higher reduction (plaque and gingival scores) was found in chlorhexidine when compared with the Aloe vera group. However, no significant difference was seen between chlorhexidine and chlorine dioxide with respect to mean reduction in plaque and gingival scores. Conclusion Chlorine dioxide can be a suitable and economical alternative for chlorhexidine. Further long-term studies are recommended for evaluating their effectiveness. PMID:26937371

  1. Platelet-Rich Plasma (PRP) Rinses for the Treatment of Non-Responding Oral Lichen Planus: A Case Report.

    Science.gov (United States)

    Merigo, Elisabetta; Oppici, Aldo; Parlatore, Anna; Cella, Luigi; Clini, Fabio; Fontana, Matteo; Fornaini, Carlo

    2018-02-06

    Platelet-rich plasma (PRP) has been proposed for different applications in the medical field and in maxillofacial surgery thanks to its many growth factors, such as epidermal growth factor (EGF), fibroblast growth factor (FGF), and keratinocyte growth factor (KGF). Oral lichen planus (OLP) is a disease that affects the oral mucosa in a chronic way. This disease frequently worsens the quality of life of patients, particularly when clinical manifestations are of the erythematous or erosive/ulcerative type. The properties of PRP that are supported by scientific literature in both oral medicine and other medical fields have suggested the introduction of PRP in clinical practice for the medical treatment of different soft tissues diseases, such as when OLP patients do not respond to conventional therapies, or when conventional treatments have some contraindications or side effects. The aim of this work is to describe the use of PRP used as an oral rinse for the treatment of a patient diagnosed as affected by OLP at the Dentistry, Special Needs and Maxillo-Facial Surgery Unit of the Hospital of Piacenza. PRP protocol was started after the failure of conventional therapies based on the use of topical and systemic corticosteroids, hydroxychloroquine, and low-level laser therapy applications.

  2. Platelet-Rich Plasma (PRP Rinses for the Treatment of Non-Responding Oral Lichen Planus: A Case Report

    Directory of Open Access Journals (Sweden)

    Elisabetta Merigo

    2018-02-01

    Full Text Available Platelet-rich plasma (PRP has been proposed for different applications in the medical field and in maxillofacial surgery thanks to its many growth factors, such as epidermal growth factor (EGF, fibroblast growth factor (FGF, and keratinocyte growth factor (KGF. Oral lichen planus (OLP is a disease that affects the oral mucosa in a chronic way. This disease frequently worsens the quality of life of patients, particularly when clinical manifestations are of the erythematous or erosive/ulcerative type. The properties of PRP that are supported by scientific literature in both oral medicine and other medical fields have suggested the introduction of PRP in clinical practice for the medical treatment of different soft tissues diseases, such as when OLP patients do not respond to conventional therapies, or when conventional treatments have some contraindications or side effects. The aim of this work is to describe the use of PRP used as an oral rinse for the treatment of a patient diagnosed as affected by OLP at the Dentistry, Special Needs and Maxillo-Facial Surgery Unit of the Hospital of Piacenza. PRP protocol was started after the failure of conventional therapies based on the use of topical and systemic corticosteroids, hydroxychloroquine, and low-level laser therapy applications.

  3. Effect of green tea mouth rinse on Streptococcus mutans in plaque and saliva in children: An in vivo study

    Directory of Open Access Journals (Sweden)

    Anil Kumar Goyal

    2017-01-01

    Full Text Available Aims: This study was conducted to evaluate and compare the antimicrobial efficacy of green tea catechin as a mouth wash on colony count of Streptococcus mutans in children. Materials and Methods: A sample size of thirty children was selected out of screened 290 children by simple random sampling between the age group of 7 and 12 years. The study was conducted over a period of 2 weeks. After 24 h of oral prophylaxis, the baseline samples were collected and each group was subjected to mouth rinsing with green tea mouth wash for 2 weeks and further plaque and saliva samples were collected at 1- and 2-week intervals from baseline. Microbiological analysis of plaque and saliva samples was done by Dentocult SM strip kit (Orion Diagnostica, Finland, and the results were statistically analyzed and tabulated. Results: Statistically, there was highly significant reduction in S. mutans count in plaque as well as in saliva for after 1- and 2-week intervals from baseline. Conclusion: Hence, finally, our study showed that green tea catechin is effective as a mouth wash against S. mutans and having better action in plaque as compared to saliva. It can be used as an adjunct to commercially available mouthwashes.

  4. Microbiological Effect of Essential Oils in Combination with Subgingival Ultrasonic Instrumentation and Mouth Rinsing in Chronic Periodontitis Patients

    Directory of Open Access Journals (Sweden)

    Toshiya Morozumi

    2013-01-01

    Full Text Available Thirty chronic periodontitis patients were randomly assigned to 3 groups: control, saline, and essential oil-containing antiseptic (EO. Subgingival plaque was collected from a total of 90 pockets across all subjects. Subsequently, subgingival ultrasonic instrumentation (SUI was performed by using EO or saline as the irrigation agent. After continuous mouth rinsing at home with EO or saline for 7 days, subgingival plaques were sampled again. Periodontopathic bacteria were quantified using the modified Invader PLUS assay. The total bacterial count in shallow pockets (probing pocket depth (PPD = 4-5 mm was significantly reduced in both saline (P<0.05 and EO groups (P<0.01. The total bacterial count (P<0.05 and Porphyromonas gingivalis (P<0.01 and Tannerella forsythia (P<0.05 count in deep pockets (PPD ≥6 mm were significantly reduced only in the EO group. In comparisons of the change ratio relative to baseline value of total bacteria counts across categories, both the saline and EO groups for PPD 4-5 mm and the EO group for PPD 6 mm showed a significantly low ratio (P<0.05. The adjunctive use of EO may be effective in reducing subgingival bacterial counts in both shallow and deep pockets. This trial is registered with UMIN Clinical Trials Registry UMIN000007484.

  5. Fundamental processes in ion plating

    International Nuclear Information System (INIS)

    Mattox, D.M.

    1980-01-01

    Ion plating is a generic term applied to film deposition processes in which the substrate surface and/or the depositing film is subjected to a flux of high energy particles sufficient to cause changes in the interfacial region of film properties compared to a nonbombarded deposition. Ion plating is being accepted as an alternative coating technique to sputter deposition, vacuum evaporation and electroplating. In order to intelligently choose between the various deposition techniques, the fundamental mechanisms, relating to ion plating, must be understood. This paper reviews the effects of low energy ion bombardment on surfaces, interface formation and film development as they apply to ion plating and the implementation and applications of the ion plating process

  6. [Prospective randomized study regarding the effect of the preoperative antibiotic and chlorhexidine rinse on wound healing after mandibular third molar surgery].

    Science.gov (United States)

    Kaposvári, István; Körmöczi, Kinga; László, Zsuzsa Beáta; Oberna, Ferenc; Horváth, Ferenc; Joób-Fancsaly, Árpád

    2017-01-01

    The study compares the antibiotic prophylaxis combined with postoperative antibiotic therapy to preoperative chlorhexidine rinse combined with postoperative antibiotic therapy in preventing complications after surgical removal of a mandibular third molar. 71 healthy patients in four groups were enrolled in the study: I. prophylactic dose of 2000 mg of amoxicillin clavulanate, continued with amoxicillin clavulanate postoperatively; II. prophylactic dose of 600 mg of clindamycin, continued with clindamycin postoperatively; III. prophylactic chlorhexidin rinsing, continued randomized amoxicillin clavulanate or clindamycin postoperatively; IV. control, with clindamycin postoperatively. The pain was smaller in the prophylaxis groups. Alveolitis occurred only in the control group: 2 patients. Wound opening occurred in 22,2 % in group IV., 14,2 % in group II, 10 % in group I., 5 % in group III. We consider completing the indicated postoperative antibiotic prescription with antibiotic or antiseptic prophylaxis. Chlorhexidin prophylaxis could have the same positive effect. Orv. Hetil., 2017, 158(1), 13-19.

  7. Vertical steam generator with slab-type tube-plate with even tube bundle washing

    International Nuclear Information System (INIS)

    Manek, O.; Masek, V.; Motejl, V.; Quitta, R.

    1980-01-01

    A shielding plate supporting the tubes attached to the tube plate of a vertical steam generator is mounted above the tube plate. Tube sleeves are designed with a dimensional tolerance relative to the heat transfer tubes and the sleeve end and the tube plate end. A separate space is thus formed above the tube plate in which circulation or feed water is introduced to flow between the branch and the heat transfer tube. This provides intensive washing of heat transfer tubes at a critical point and prevents deposit formation, thus excluding heat transfer tube failures. (J.B.)

  8. A systematic review of the effectiveness of antimicrobial rinse-free hand sanitizers for prevention of illness-related absenteeism in elementary school children

    OpenAIRE

    Meadows, Emily; Le Saux, Nicole

    2004-01-01

    Abstract Background Absenteeism due to communicable illness is a major problem encountered by North American elementary school children. Although handwashing is a proven infection control measure, barriers exist in the school environment, which hinder compliance to this routine. Currently, alternative hand hygiene techniques are being considered, and one such technique is the use of antimicrobial rinse-free hand sanitizers. Methods A systematic review was conducted to examine the effectivenes...

  9. [Research on cleaning rate of the C-shaped canal treated by manual or rotary endodontic file combined with ultrasonic rinsing].

    Science.gov (United States)

    Wang, Jing; Gao, Yan; Wang, Qing-shan; Zhang, Yan; Rong, Li; Wang, Jiu

    2014-08-01

    To evaluate the cleaning effect of the C-shaped canal treated by manual K file and ProTaper rotary endodontic file combined with ultrasonic cleaning, and find a better cleaning program for the C-shaped root canal. Fifty mandibular second molars were randomly divided into 5 groups: K file group, K file+ultrasonic rinsing group, ProTaper group, ProTaper+ultrasonic rinsing group and the control group. After initial shaping and cleaning, the mandibular second molars were soaked in formalin and stained. Under microscopy, the cleaning rate of necrotic tissue and cutting area were observed and analyzed. The data was processed with SPSS 17.0 software package. The cleaning rates of the treated groups were significantly higher than that of the control group (P<0.05); In each treatment group, the cleaning rate of the apex was significantly lower than that of the crown and central part (P<0.05); The cutting score of ProTaper+ultrasonic cleaning group was lower than that of the other treatment groups; The cutting score of the K file+ultrasonic rinsing group was significantly lower than that of the K file group (P<0.05); The cutting score and cleaning rate were negatively correlated (r=-0.712, P=0.000 ), the linear regression was the cleaning rate =98.325-4.325 × wall cutting score (R=0.454, P<0.05). In the process of shaping and cleaning of C-shaped canal, it is recommended that the ProTaper nickel-titanium rotary endodontic file should be chosen to clean the top of the taproot pipe and combined with ultrasonic rinsing to achieve better results.

  10. Water

    Science.gov (United States)

    ... drink and water in food (like fruits and vegetables). 6. Of all the earth’s water, how much is ocean or seas? 97 percent of the earth’s water is ocean or seas. 7. How much of the world’s water is frozen? Of all the water on earth, about 2 percent is frozen. 8. How much ...

  11. The Golosyiv plate archive digitisation

    Science.gov (United States)

    Sergeeva, T. P.; Sergeev, A. V.; Pakuliak, L. K.; Yatsenko, A. I.

    2007-08-01

    The plate archive of the Main Astronomical Observatory of the National Academy of Sciences of Ukraine (Golosyiv, Kyiv) includes about 85 000 plates which have been taken in various observational projects during 1950-2005. Among them are about 25 000 of direct northern sky area plates and more than 600 000 plates containing stellar, planetary and active solar formations spectra. Direct plates have a limiting magnitude of 14.0-16.0 mag. Since 2002 we have been organising the storage, safeguarding, cataloguing and digitization of the plate archive. The very initial task was to create the automated system for detection of astronomical objects and phenomena, search of optical counterparts in the directions of gamma-ray bursts, research of long period, flare and other variable stars, search and rediscovery of asteroids, comets and other Solar System bodies to improve the elements of their orbits, informational support of CCD observations and space projects, etc. To provide higher efficiency of this work we have prepared computer readable catalogues and database for 250 000 direct wide field plates. Now the catalogues have been adapted to Wide Field Plate Database (WFPDB) format and integrated into this world database. The next step will be adaptation of our catalogues, database and images to standards of the IVOA. Some magnitude and positional accuracy estimations for Golosyiv archive plates have been done. The photometric characteristics of the images of NGC 6913 cluster stars on two plates of the Golosyiv's double wide angle astrograph have been determined. Very good conformity of the photometric characteristics obtained with external accuracies of 0.13 and 0.15 mag. has been found. The investigation of positional accuracy have been made with A3± format fixed bed scanner (Microtek ScanMaker 9800XL TMA). It shows that the scanner has non-detectable systematic errors on the X-axis, and errors of ± 15 μm on the Y-axis. The final positional errors are about ± 2 μm (

  12. Indonesian Landforms and Plate Tectonics

    Directory of Open Access Journals (Sweden)

    Herman Th. Verstappen

    2014-06-01

    Full Text Available DOI: 10.17014/ijog.v5i3.103The horizontal configuration and vertical dimension of the landforms occurring in the tectonically unstable parts of Indonesia were resulted in the first place from plate tectonics. Most of them date from the Quaternary and endogenous forces are ongoing. Three major plates – the northward moving Indo-Australian Plate, the south-eastward moving SE-Asian Plate and the westward moving Pacific Plate - meet at a plate triple-junction situated in the south of New Guinea’s Bird’s Head. The narrow North-Moluccan plate is interposed between the Asia and Pacific. It tapers out northward in the Philippine Mobile Belt and is gradually disappearing. The greatest relief amplitudes occur near the plate boundaries: deep ocean trenches are associated with subduction zones and mountain ranges with collision belts. The landforms of the more stable areas of the plates date back to a more remote past and, where emerged, have a more subdued relief that is in the first place related to the resistance of the rocks to humid tropical weathering Rising mountain ranges and emerging island arcs are subjected to rapid humid-tropical river erosions and mass movements. The erosion products accumulate in adjacent sedimentary basins where their increasing weight causes subsidence by gravity and isostatic compensations. Living and raised coral reefs, volcanoes, and fault scarps are important geomorphic indicators of active plate tectonics. Compartmental faults may strongly affect island arcs stretching perpendicular to the plate movement. This is the case on Java. Transcurrent faults and related pull-apart basins are a leading factor where plates meet at an angle, such as on Sumatra. The most complicated situation exists near the triple-junction and in the Moluccas. Modern research methods, such as GPS measurements of plate movements and absolute dating of volcanic outbursts and raised coral reefs are important tools. The mega-landforms resulting

  13. A systematic review of the effectiveness of antimicrobial rinse-free hand sanitizers for prevention of illness-related absenteeism in elementary school children

    Science.gov (United States)

    Meadows, Emily; Le Saux, Nicole

    2004-01-01

    Background Absenteeism due to communicable illness is a major problem encountered by North American elementary school children. Although handwashing is a proven infection control measure, barriers exist in the school environment, which hinder compliance to this routine. Currently, alternative hand hygiene techniques are being considered, and one such technique is the use of antimicrobial rinse-free hand sanitizers. Methods A systematic review was conducted to examine the effectiveness of antimicrobial rinse-free hand sanitizer interventions in the elementary school setting. MEDLINE, EMBASE, Biological Abstract, CINAHL, HealthSTAR and Cochrane Controlled Trials Register were searched for both randomized and non-randomized controlled trials. Absenteeism due to communicable illness was the primary outcome variable. Results Six eligible studies, two of which were randomized, were identified (5 published studies, 1 published abstract). The quality of reporting was low. Due to a large amount of heterogeneity and low quality of reporting, no pooled estimates were calculated. There was a significant difference reported in favor of the intervention in all 5 published studies. Conclusions The available evidence for the effectiveness of antimicrobial rinse-free hand sanitizer in the school environment is of low quality. The results suggest that the strength of the benefit should be interpreted with caution. Given the potential to reduce student absenteeism, teacher absenteeism, school operating costs, healthcare costs and parental absenteeism, a well-designed and analyzed trial is needed to optimize this hand hygiene technique. PMID:15518593

  14. A systematic review of the effectiveness of antimicrobial rinse-free hand sanitizers for prevention of illness-related absenteeism in elementary school children

    Directory of Open Access Journals (Sweden)

    Le Saux Nicole

    2004-11-01

    Full Text Available Abstract Background Absenteeism due to communicable illness is a major problem encountered by North American elementary school children. Although handwashing is a proven infection control measure, barriers exist in the school environment, which hinder compliance to this routine. Currently, alternative hand hygiene techniques are being considered, and one such technique is the use of antimicrobial rinse-free hand sanitizers. Methods A systematic review was conducted to examine the effectiveness of antimicrobial rinse-free hand sanitizer interventions in the elementary school setting. MEDLINE, EMBASE, Biological Abstract, CINAHL, HealthSTAR and Cochrane Controlled Trials Register were searched for both randomized and non-randomized controlled trials. Absenteeism due to communicable illness was the primary outcome variable. Results Six eligible studies, two of which were randomized, were identified (5 published studies, 1 published abstract. The quality of reporting was low. Due to a large amount of heterogeneity and low quality of reporting, no pooled estimates were calculated. There was a significant difference reported in favor of the intervention in all 5 published studies. Conclusions The available evidence for the effectiveness of antimicrobial rinse-free hand sanitizer in the school environment is of low quality. The results suggest that the strength of the benefit should be interpreted with caution. Given the potential to reduce student absenteeism, teacher absenteeism, school operating costs, healthcare costs and parental absenteeism, a well-designed and analyzed trial is needed to optimize this hand hygiene technique.

  15. A systematic review of the effectiveness of antimicrobial rinse-free hand sanitizers for prevention of illness-related absenteeism in elementary school children.

    Science.gov (United States)

    Meadows, Emily; Le Saux, Nicole

    2004-11-01

    Absenteeism due to communicable illness is a major problem encountered by North American elementary school children. Although handwashing is a proven infection control measure, barriers exist in the school environment, which hinder compliance to this routine. Currently, alternative hand hygiene techniques are being considered, and one such technique is the use of antimicrobial rinse-free hand sanitizers. A systematic review was conducted to examine the effectiveness of antimicrobial rinse-free hand sanitizer interventions in the elementary school setting. MEDLINE, EMBASE, Biological Abstract, CINAHL, HealthSTAR and Cochrane Controlled Trials Register were searched for both randomized and non-randomized controlled trials. Absenteeism due to communicable illness was the primary outcome variable. Six eligible studies, two of which were randomized, were identified (5 published studies, 1 published abstract). The quality of reporting was low. Due to a large amount of heterogeneity and low quality of reporting, no pooled estimates were calculated. There was a significant difference reported in favor of the intervention in all 5 published studies. The available evidence for the effectiveness of antimicrobial rinse-free hand sanitizer in the school environment is of low quality. The results suggest that the strength of the benefit should be interpreted with caution. Given the potential to reduce student absenteeism, teacher absenteeism, school operating costs, healthcare costs and parental absenteeism, a well-designed and analyzed trial is needed to optimize this hand hygiene technique.

  16. Salivary pH after a glucose rinse: effect of a new mucoadhesive spray (Cariex) based on sodium bicarbonate and xylitol.

    Science.gov (United States)

    Abbate, G M; Levrini, L; Caria, M P

    2014-01-01

    This study evaluated whether sodium bicarbonate applied on the oral mucosa through a new mucoadhesive spray (Cariex) could control a drop in salivary pH after a glucose rinse, and therefore enhance the buffering potential of saliva. A sample of 50 healthy adults was selected. At day 1, the measurement of salivary pH was performed in the lower fornix in correspondence with the lower molars. Each subject rinsed with 10 ml of a 10% glucose solution and then pH was monitored continually for 40 minutes. At day 2, the same experimental procedure was repeated and three shots of the spray were administered on the oral mucosa. The tested spray is composed of sodium bicarbonate, xylitol, and excipients. Without the mucoadhesive spray, salivary pH became significantly lower following the glucose rinse (p pH remained lower than 6.0 was reduced statistically significantly (p salivary pH was observed for the 40 minutes in which the pH recording was performed. Conclusions: The use of a sodium bicarbonate spray on the mucosa was shown to control the lowering of salivary pH following carbohydrate consumption, and might therefore add to the prevention of caries and dental erosion.

  17. Microelement Exploration Water Flow of Rimnik River

    OpenAIRE

    , N. Bajraktari; , B. Baraj; , T. Arbneshi; , S. Jusufi

    2016-01-01

    Compared to the increasing need on qualitative water use, many water şows are subject to a rising pollution by urban and industrial untreated water discharge, and in some cases by incidental run-offs. Besides them, there is also a great impact made by disseminated agricultural pollution and air and soil rinsing after atmospheric rainfalls. The main purpose of this paper is the micro-element exploration in water and sediments, along the water şow of Rimnik River. Some of the heavy metals: Pb, ...

  18. Create Your Plate

    Medline Plus

    Full Text Available ... your meal, add a low-calorie drink like water, unsweetened tea or coffee. Featured Product Precise Portions® Go Healthy Travel Pack (4/Box) Taking the guesswork out of portion control has never been easier. It can be a ...

  19. Create Your Plate

    Medline Plus

    Full Text Available ... drink like water, unsweetened tea or coffee. Featured Product Precise Portions® Go Healthy Travel Pack (4/Box) Taking the guesswork out of portion control has never been easier. It can be a challenge to manage portion control wherever you are. Now, ...

  20. Create Your Plate

    Medline Plus

    Full Text Available ... low-calorie drink like water, unsweetened tea or coffee. Featured Product Precise Portions® Go Healthy Travel Pack ( ... to Give Do-It-Yourself Fundraising & Local Events Promotions that Give Back Donate Your Collectibles Donate Stocks ...

  1. Water

    International Nuclear Information System (INIS)

    Chovanec, A.; Grath, J.; Kralik, M.; Vogel, W.

    2002-01-01

    An up-date overview of the situation of the Austrian waters is given by analyzing the status of the water quality (groundwater, surface waters) and water protection measures. Maps containing information of nitrate and atrazine in groundwaters (analyses at monitoring stations), nitrate contents and biological water quality of running waters are included. Finally, pollutants (nitrate, orthophosphate, ammonium, nitrite, atrazine etc.) trends in annual mean values and median values for the whole country for the years 1992-1999 are presented in tables. Figs. 5. (nevyjel)

  2. Plate shell structures of glass

    DEFF Research Database (Denmark)

    Bagger, Anne

    to their curved shape. A plate shell structure maintains a high stiffness-to-weight ratio, while facilitating the use of plane structural elements. The study focuses on using laminated glass panes for the load bearing facets. Various methods of generating a plate shell geometry are suggested. Together with Ghent......, such as facet size, imperfections, and connection characteristics. The critical load is compared to that of a similar, but smoothly curved, shell structure. Based on the investigations throughout the study, a set of guidelines for the structural design of plate shells of glass is proposed....

  3. Plating on stainless steel alloys

    International Nuclear Information System (INIS)

    Dini, J.W.; Johnson, H.R.

    1981-01-01

    Quantitative adhesion data are presented for a variety of electroplated stainless steel type alloys. Results show that excellent adhesion can be obtained by using a Wood's nickel strike or a sulfamate nickel strike prior to final plating. Specimens plated after Wood's nickel striking failed in the deposit rather than at the interface between the substrate and the coating. Flyer plate quantitative tests showed that use of anodic treatment in sulfuric acid prior to Wood's nickel striking even further improved adhesion. In contrast activation of stainless steels by immersion or cathodic treatment in hydrochloric acid resulted in very reduced bond strengths with failure always occurring at the interface between the coating and substrate

  4. Is plate tectonics needed to evolve technological species on exoplanets?

    Directory of Open Access Journals (Sweden)

    Robert J. Stern

    2016-07-01

    Full Text Available As we continue searching for exoplanets, we wonder if life and technological species capable of communicating with us exists on any of them. As geoscientists, we can also wonder how important is the presence or absence of plate tectonics for the evolution of technological species. This essay considers this question, focusing on tectonically active rocky (silicate planets, like Earth, Venus, and Mars. The development of technological species on Earth provides key insights for understanding evolution on exoplanets, including the likely role that plate tectonics may play. An Earth-sized silicate planet is likely to experience several tectonic styles over its lifetime, as it cools and its lithosphere thickens, strengthens, and becomes denser. These include magma ocean, various styles of stagnant lid, and perhaps plate tectonics. Abundant liquid water favors both life and plate tectonics. Ocean is required for early evolution of diverse single-celled organisms, then colonies of cells which specialized further to form guts, appendages, and sensory organisms up to the complexity of fish (central nervous system, appendages, eyes. Large expanses of dry land also begin in the ocean, today produced above subduction zones in juvenile arcs and by their coalescence to form continents, although it is not clear that plate tectonics was required to create continental crust on Earth. Dry land of continents is required for further evolution of technological species, where modification of appendages for grasping and manipulating, and improvement of eyes and central nervous system could be perfected. These bioassets allowed intelligent creatures to examine the night sky and wonder, the beginning of abstract thinking, including religion and science. Technology arises from the exigencies of daily living such as tool-making, agriculture, clothing, and weapons, but the pace of innovation accelerates once it is allied with science. Finally, the importance of plate

  5. Water

    Science.gov (United States)

    ... can be found in some metal water taps, interior water pipes, or pipes connecting a house to ... reduce or eliminate lead. See resources below. 5. Children and pregnant women are especially vulnerable to the ...

  6. Attempts of Thermal Imaging Camera Usage in Estimations of the Convective Heat Loss From a Vertical Plate

    Directory of Open Access Journals (Sweden)

    Denda Hubert

    2014-01-01

    Full Text Available In this paper a new method for determining heat transfer coefficients using a gradient method has been developed. To verify accuracy of the proposed method vertical isothermal heating plate with natural convection mechanism has been examined. This configuration was deliberately chosen, because of the fact that such case is historically the earliest and most thoroughly studied and its rich scientific documentation – the most reliable. New method is based on temperature field visualization made in perpendicular plane to the heating surface of the plate using infrared camera. Because the camera does not record temperature of air itself but the surface only, therefore plastic mesh with low thermal conductivity has been used as a detector. Temperature of each mesh cell, placed perpendicular to the vertical heating surface and rinsed with convection stream of heated air could be already recorded by infrared camera. In the same time using IR camera surface of heating plate has been measured. By numerical processing of the results matrix temperature gradient on the surface ∂T/∂x │ x=0, local heat transfer coefficients αy, and local values of Nusselt number Nuy, can be calculated. After integration the average Nusselt number for entire plate can be calculated. Obtained relation characteristic numbers Nu = 0.647 Ra 0.236 (R2 = 0.943, has a good correlation with literature reports and proves usefulness of the method.

  7. Field investigation of arsenic in ceramic pot filter-treated drinking water.

    Science.gov (United States)

    Archer, A R; Elmore, A C; Bell, E; Rozycki, C

    2011-01-01

    Ceramic pot filters (CPFs) is one of several household water treatment technologies that is used to treat drinking water in developing areas. The filters have the advantage of being able to be manufactured using primarily locally available materials and local labor. However, naturally-occurring arsenic present in the clay used to make the filters has the potential to contaminate the water in excess of the World Health Organization drinking water standard of 0.01 mg/L. A manufacturing facility in Guatemala routinely rinses filters to reduce arsenic concentrations prior to distribution to consumers. A systemic study was performed to evaluate the change in arsenic concentrations with increasing volumes of rinse water. Arsenic field kit results were compared to standard method laboratory results, and dissolved versus suspended arsenic concentrations in CPF-treated water were evaluated. The results of the study suggest that rinsing is an effective means of mitigating arsenic leached from the filters, and that even in the absence of a formal rinsing program, routine consumer use may result in the rapid decline of arsenic concentrations. More importantly, the results indicate that filter manufacturers should give strong consideration to implementing an arsenic testing program.

  8. Correlation between degree of conversion, resin-dentin bond strength and nanoleakage of simplified etch-and-rinse adhesives.

    Science.gov (United States)

    Hass, Viviane; Dobrovolski, Max; Zander-Grande, Christiana; Martins, Gislaine Cristine; Gordillo, Luís Alfonso Arana; Rodrigues Accorinte, Maria de Lourdes; Gomes, Osnara Maria Mongruel; Loguercio, Alessandro Dourado; Reis, Alessandra

    2013-09-01

    The aim of this study was to correlate the degree of conversion measured inside the hybrid layer (DC) with the microtensile resin-dentin bond strength (μTBS) and silver nitrate uptake or nanoleakage (SNU) for five simplified etch-and-rinse adhesive systems. Fifty-five caries free extracted molars were used in this study. Thirty teeth were used for μTBS/SNU [n=6] and 25 teeth for DC [n=5]. The dentin surfaces were bonded with the following adhesives: Adper Single Bond 2 (SB), Ambar (AB), XP Bond (XP), Tetric N-Bond (TE) and Stae (ST) followed by composite resin build-ups. For μTBS and SNU test, bonded teeth were sectioned in order to obtain stick-shaped specimens (0.8mm(2)), which were tested under tensile stress (0.5mm/min). Three bonded sticks, from each tooth, were not tested in tensile stress and they were immersed in 50% silver nitrate, photo-developed and analyzed by scanning electron microscopy. Longitudinal 1-mm thick sections were prepared for the teeth assigned for DC measurement and evaluated by micro-Raman spectroscopy. ST showed lowest DC, μTBS, and higher SNU (p0.05), except for TE which showed an intermediate SNU level. The DC was positively correlated with μTBS and negatively correlated with SNU (p<0.05). SNU was also negatively correlated with μTBS (p<0.05). The measurement of DC inside the hybrid layer can provide some information about bonding performance of adhesive systems since this property showed a good correlation with resin-dentin bond strength and SNU values. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  9. Effect of root canal rinsing protocol on dentin bond strength of two resin cements using three different method of test.

    Science.gov (United States)

    Khoroushi, Maryam; Sheikhi, Mohammadreza; Khalilian-Gourtani, Amirhossein; Soleimani, Bahram

    2016-07-01

    Different studies have used different tests to evaluate bond strength of resin cements to root dentin. In this in vitrostudy, three different tests were used to evaluate the bond strength of two resin cements to root dentin using two root dentin irrigation protocols. Ninety-six intact single-rooted teeth were selected for this study. Forty-eight teeth, with a root length of 15mm, were randomly divided into two groups and irrigated with normal saline or 2.5% sodium hypochlorite solutions during root canal preparation, respectively. For each 12 specimens from each group, fiber post #1 was bonded using an etch-and-rinse (Duo-Link) and a self-adhesive (BisCem) resin cement, respectively. After incubation, two specimens were prepared for the push-out test from the middle thirds of the roots. In another 24 teeth, after two 1.5-mm sections were prepared from the middle thirds of the prepared roots, sections of the post were bonded in two subgroups with each of the cements mentioned above and the samples were prepared for the pull-out test. For shear test, the crowns of 48 teeth were cut away, the dentin surfaces were prepared, the two irrigation solutions were used, and the resin cements were bonded. Data collected from the three tests were evaluated by ANOVA, post-hoc Tukey and Weibull tests (α=0.05). There were significant differences in the mean bond strength values between the three bond strength tests (Pstrength in all tests (P>0.05). Under the limitations of the present study, the method of the test used had an effect on the recorded bond strength between the resin cement and root dentin. Cement type and irrigation protocol resulted in similar variations with all the tests. Push-out and shear tests exhibited more coherent results. Bond strength, endodontically treated tooth, fiber post, resin cement, sodium hypochlorite.

  10. Quantification of Campylobacter spp. in chicken rinse samples by using flotation prior to real-time PCR.

    Science.gov (United States)

    Wolffs, Petra; Norling, Börje; Hoorfar, Jeffrey; Griffiths, Mansel; Rådström, Peter

    2005-10-01

    Real-time PCR is fast, sensitive, specific, and can deliver quantitative data; however, two disadvantages are that this technology is sensitive to inhibition by food and that it does not distinguish between DNA originating from viable, viable nonculturable (VNC), and dead cells. For this reason, real-time PCR has been combined with a novel discontinuous buoyant density gradient method, called flotation, in order to allow detection of only viable and VNC cells of thermotolerant campylobacters in chicken rinse samples. Studying the buoyant densities of different Campylobacter spp. showed that densities changed at different time points during growth; however, all varied between 1.065 and 1.109 g/ml. These data were then used to develop a flotation assay. Results showed that after flotation and real-time PCR, cell concentrations as low as 8.6 x 10(2) CFU/ml could be detected without culture enrichment and amounts as low as 2.6 x 10(3) CFU/ml could be quantified. Furthermore, subjecting viable cells and dead cells to flotation showed that viable cells were recovered after flotation treatment but that dead cells and/or their DNA was not detected. Also, when samples containing VNC cells mixed with dead cells were treated with flotation after storage at 4 or 20 degrees C for 21 days, a similar percentage resembling the VNC cell fraction was detected using real-time PCR and 5-cyano-2,3-ditolyl tetrazolium chloride-4',6'-diamidino-2-phenylindole staining (20% +/- 9% and 23% +/- 4%, respectively, at 4 degrees C; 11% +/- 4% and 10% +/- 2%, respectively, at 20 degrees C). This indicated that viable and VNC Campylobacter cells could be positively selected and quantified using the flotation method.

  11. MyPlate Daily Checklist

    Science.gov (United States)

    ... Price Tag Read the Food Label Kitchen Timesavers Cooking for Your Family Tasty & Low-Cost Recipes Sample 2-Week Menus Resources for Professionals MyPlate Tip Sheets Print Materials Infographics 5 Ways ...

  12. License plate recognition (phase B).

    Science.gov (United States)

    2010-06-01

    License Plate Recognition (LPR) technology has been used for off-line automobile enforcement purposes. The technology has seen mixed success with correct reading rate as high as 60 to 80% depending on the specific application and environment. This li...

  13. Armor Plate Surface Roughness Measurements

    National Research Council Canada - National Science Library

    Stanton, Brian; Coburn, William; Pizzillo, Thomas J

    2005-01-01

    ...., surface texture and coatings) that could become important at high frequency. We measure waviness and roughness of various plates to know the parameter range for smooth aluminum and rolled homogenous armor (RHA...

  14. Rhodium platings – experimental study

    OpenAIRE

    Rudolf, R.; Budić, B.; Stamenković, D.; Čolić, M.; Ivanič, A.; Kosec, B.

    2013-01-01

    Modern rhodium plating solutions are based on either sulphate or phosphate. Although in theory there are four possible combinations, in practice only three different rhodium electrolytes are used. These are based on dilutions of rhodium sulphate or phosphate concentrates with added sulphuric or phosphoric acid. These processes are be discussed in this paper with a demonstration of Rh platings in the Slovenian firm Zlatarna Celje d.d.

  15. Rhodium platings – experimental study

    Directory of Open Access Journals (Sweden)

    R. Rudolf

    2013-07-01

    Full Text Available Modern rhodium plating solutions are based on either sulphate or phosphate. Although in theory there are four possible combinations, in practice only three different rhodium electrolytes are used. These are based on dilutions of rhodium sulphate or phosphate concentrates with added sulphuric or phosphoric acid. These processes are be discussed in this paper with a demonstration of Rh platings in the Slovenian firm Zlatarna Celje d.d.

  16. Bioinspired plate-based fog collectors.

    Science.gov (United States)

    Heng, Xin; Luo, Cheng

    2014-09-24

    In a recent work, we explored the feeding mechanism of a shorebird to transport liquid drops by repeatedly opening and closing its beak. In this work, we apply the corresponding results to develop a new artificial fog collector. The collector includes two nonparallel plates. It has three advantages in comparison with existing artificial collectors: (i) easy fabrication, (ii) simple design to scale up, and (iii) active transport of condensed water drops. Two collectors have been built. A small one with dimensions of 4.2 × 2.1 × 0.05 cm(3) (length × width × thickness) was first built and tested to examine (i) the time evolution of condensed drop sizes and (ii) the collection processes and efficiencies on the glass, SiO2, and SU-8 plates. Under similar experimental conditions, the amount of water collected per unit area on the small collector is about 9.0, 4.7, and 3.7 times, respectively, as much as the ones reported for beetles, grasses, and metal wires, and the total amount of water collected is around 33, 18, and 15 times. On the basis of the understanding gained from the tests on the small collector, a large collector with dimensions of 26 × 10 × 0.2 cm(3) was further built and tested, which was capable of collecting 15.8 mL of water during a period of 36 min. The amount of water collected, when it is scaled from 36 to 120 min, is about 878, 479, or 405 times more than what was collected by individual beetles, grasses, or metal wires.

  17. Heat transfer studies on spiral plate heat exchanger

    Directory of Open Access Journals (Sweden)

    Rajavel Rangasamy

    2008-01-01

    Full Text Available In this paper, the heat transfer coefficients in a spiral plate heat exchanger are investigated. The test section consists of a plate of width 0.3150 m, thickness 0.001 m and mean hydraulic diameter of 0.01 m. The mass flow rate of hot water (hot fluid is varying from 0.5 to 0.8 kg/s and the mass flow rate of cold water (cold fluid varies from 0.4 to 0.7 kg/s. Experiments have been conducted by varying the mass flow rate, temperature, and pressure of cold fluid, keeping the mass flow rate of hot fluid constant. The effects of relevant parameters on spiral plate heat exchanger are investigated. The data obtained from the experimental study are compared with the theoretical data. Besides, a new correlation for the Nusselt number which can be used for practical applications is proposed.

  18. Saline Sinus Rinse Recipe

    Science.gov (United States)

    ... Conditions Drug Guide Conditions Dictionary Just for Kids Library School Tools Videos Virtual Allergist Education & Training Careers in ... Support the AAAAI Foundation Donate Utility navigation Español Journals Annual Meeting Member Login / My Membership Search navigation ...

  19. THERMAL PERFORMANCE OF FLAT PLATE SOLAR COLLECTOR

    Directory of Open Access Journals (Sweden)

    TABET I.

    2017-06-01

    Full Text Available In this paper, a theoretical and experimental studyof flat platesolar water collector with reflectors.A mathematical model based on energy balance equations saw the thermal behavior of the collector is investigated. The experimental test was made at the unit research applies in renewable energy (URAER located in southern Algeria.An increase of 23% for solar radiation incident on the collector surface with the addition of the planers reflectors in the day of May, this increase causes an improvement of the performance of the collector,the fluid temperature increases with an average of 5%. Thetests conducted on the flat plate solar water collector in open circuit enabled the determination of thermal performance of the collector by estimating the daily output The thermal efficiency of the collector ranges from 1% -63% during the day, a mean value of 36%obtained.

  20. Coupling intensity and isostatic competition between subducting slab and overriding plate control trench motions and tectonics of the overriding plate

    Science.gov (United States)

    Wu, G.; Moresi, L. N.

    2017-12-01

    Trench motions not only reflect tectonic regimes on the overriding plate but also shed light on the competition between subducting slab and overriding plate, however, major controls over trench advance or retreat and their consequences are still illusive. We use 2D thermo-mechanical experiments to study the problem. We find that the coupling intensity particularly in the uppermost 200 km and the isostatic competition between subducting slab and overriding plate largely determine trench motion and tectonics of in the overriding plate. Coupling intensity is the result of many contributing factors, including frictional coefficient of brittle part of the subducting interface and the viscosity of the ductile part, thermal regime and rheology of the overriding plate, and water contents and magmatic activity in the subducting slab and overriding plate. In this study, we are not concerned with the dynamic evolution of individual controlling parameter but simply use effective media. For instance, we impose simple model parameters such as frictional coefficient and vary the temperature and strain-rate dependent viscosity of the weak layer between the subducting slab and overriding plate. In the coupled end-member case, strong coupling leads to strong corner flow, depth-dependent compression/extension, and mantle return flow on the overriding plate side. It results in fast trench retreat, broad overriding plate extension, and even slab breakoff. In the decoupled end-member case, weak coupling causes much weaker response on the overriding plate side compared with the coupled end-member case, and the subducting slab can be largely viewed as a conveyer belt. We find that the isostatic competition between the subducting slab and overriding plate also has a major control over trench motion, and may better be viewed in 3D models. This is consistent with the findings in previous 3D studies that trench motion is most pronounced close to the slab edge. Here we propose that the

  1. Experimental investigation of the unsteady two-phase flow through perforated plates

    International Nuclear Information System (INIS)

    Tartaglia, G.P.

    1985-07-01

    The coolant flow across the perforated dip-plate during a hypothetical core disruptive accident (HCDA) in a liquid metal fast breeder reactor was simulated in a one-dimensional model. Experiments with a water-air mixture as fluid were run by varying the following parameters: geometry of the dip-plate (perforation ratio, number of the holes), height of the fluid head over the dip-plate, air volumetric fraction, size of the air bubbles, acceleration of the fluid. The pressure drop across the dip-plate, the forces acting on the dip-plate and on the upper plate, acceleration and displacement of the piston, the air volumetric fraction and the size of the air bubbles were measured in a wide range of Strouhal and acceleration numbers. The flow pattern downstream the dip-plate was filmed with a high-speed camera. The following correlations were investigated: resistance coefficients as a function of the acceleration and Strouhal number, time delay of the force on the upper plate as a function of the cavitation number, and forces and impulses acting on the upper plate compared with those acting on the dip-plate. Finally, using high-speed film pictures, the formation of fluid jets downstream the dip-plate was investigated. The following relations were obtained: displacement of the mixture surface and of the jets as a function of the perforation ratio and of the air volumetric fraction, and cavitation volume as a function of the cavitation number. (orig.) [de

  2. Modeling RERTR experimental fuel plates using the PLATE code

    International Nuclear Information System (INIS)

    Hayes, S.L.; Meyer, M.K.; Hofman, G.L.; Snelgrove, J.L.; Brazener, R.A.

    2003-01-01

    Modeling results using the PLATE dispersion fuel performance code are presented for the U-Mo/Al experimental fuel plates from the RERTR-1, -2, -3 and -5 irradiation tests. Agreement of the calculations with experimental data obtained in post-irradiation examinations of these fuels, where available, is shown to be good. Use of the code to perform a series of parametric evaluations highlights the sensitivity of U-Mo dispersion fuel performance to fabrication variables, especially fuel particle shape and size distributions. (author)

  3. Plating on some difficult-to-plate metals and alloys

    International Nuclear Information System (INIS)

    Dini, J.W.; Johnson, H.R.

    1980-02-01

    Electrodeposition of coatings on metals such as beryllium, beryllium-copper, Kovar, lead, magnesium, thorium, titanium, tungsten, uranium, zirconium, and their alloys can be problematic. This is due in most cases to a natural oxide surface film that readily reforms after being removed. The procedures we recommend for plating on these metals rely on replacing the oxide film with a displacement coating, or etching to allow mechanical keying between the substrate and plated deposit. The effectiveness of the procedures is demonstrated by interface bond strengths found in ring-shear and conical-head tensile tests

  4. Electroless metal plating of plastics

    International Nuclear Information System (INIS)

    Krause, L.J.

    1986-01-01

    The product of an electroless plating process is described for plating at least one main group metal directly on a surface of a polymeric substrate comprising the steps of forming a nonaqueous solution containing a metallic salt of an alkali metal in a positive valence state and at least one main group metal in a negative valence state, the main group metal being selected from the group consisting of Ge, Sn, Pb, As, Sb, Bi, Si and Te, selecting an aromatic polymeric substrate reducible by the solublized salt and resistant to degration during the reaction, and carrying out a redox reaction between the salt in solution and the substrate by contacting the solution with the substrate for a sufficient time to oxidize and deposit the main group metal in elemental form to produce a plated substrate. The product is characterized by the plated metal being directly on the surface of the polymeric substrate and the alkali metal being retained in the plated substrate with the substrate being negatively charged with electrons transferred from the main group metal during the redox reaction

  5. Water

    CSIR Research Space (South Africa)

    Van Wyk, Llewellyn V

    2010-08-01

    Full Text Available Water scarcity is without a doubt on of the greatest threats to the human species and has all the potential to destabilise world peace. Falling water tables are a new phenomenon. Up until the development of steam and electric motors, deep groudwater...

  6. Water

    OpenAIRE

    Hertie School of Governance

    2010-01-01

    All human life depends on water and air. The sustainable management of both is a major challenge for today's public policy makers. This issue of Schlossplatz³ taps the streams and flows of the current debate on the right water governance.

  7. Electroless Plating on Plastic Induced by Selective Laser Activation

    DEFF Research Database (Denmark)

    Zhang, Yang; Tang, Peter Torben; Hansen, Hans Nørgaard

    2009-01-01

    This paper presents a new method for selective micro metallization of polymers. A Nd:YAG laser is employed to draw patterns on polymer surfaces that are submerged in a liquid (usually water). After subsequent activation with palladium chloride and followed by auto-catalytic electroless plating, c...

  8. Influence of discharged effluent on the quality of surface water ...

    African Journals Online (AJOL)

    SERVER

    2007-10-04

    Oct 4, 2007 ... “treated” effluents from the Percy Stewart waste treatment plant and the mine ... washed with detergent, rinsed with water and then with distilled .... S = sampling point, w. = water sample, s = sediment sample. 0.01. 0.1. 1. 10. 100. 1000. S1w. S1s. S2w. S2s. S3w. S3s. Sampling sites. C o n c. (m g. /l a n d u g.

  9. Marginal microleakage of resin-modified glass-ionomer and composite resin restorations: Effect of using etch-and-rinse and self-etch adhesives

    Directory of Open Access Journals (Sweden)

    Maryam Khoroushi

    2012-01-01

    Full Text Available Objectives: Previous studies have shown that dental adhesives increase the bond strength of resin-modified glass-ionomer (RMGI restorative materials to dentin. This in vitro study has evaluated the effect of etch-and-rinse and self-etch bonding systems v/s cavity conditioner, and in comparison to similar composite resin restorations on maintaining the marginal sealing of RMGI restorations. Materials and Methods: 98 rectangular cavities (2.5×3×1.5 mm were prepared on buccal and palatal aspects of 49 human maxillary premolars, randomly divided into 7 groups (N=14. The cavities in groups 1, 2 and 3 were restored using a composite resin (APX. The cavities in groups 4, 5, 6 and 7 were restored using a resin-modified glass-ionomer (Fuji II LC. Before restoring, adhesive systems (Optibond FL = OFL, three-step etch-and-rinse; One Step Plus = OSP, two-step etch-and-rinse; Clearfil Protect Bond = CPB, two-step self-etch were used as bonding agents in groups 1-6 as follow: OFL in groups 1 and 4, OSP in groups 2 and 5, and CPB in groups 3 and 6, respectively. The specimens in group 7 were restored with GC cavity conditioner and Fuji II LC. All the specimens were thermo-cycled for 1000 cycles. Microleakage scores were determined using dye penetration method. Statistical analyzes were carried out with Kruskal-Wallis and Mann-Whitney U tests (α=0.05. Results: There were significant differences in microleakage scores at both enamel and dentinal margins between the study groups (P<0.05. The lowest microleakage scores at enamel and dentin margins of RMGI restorations were observed in group 6. Conclusion: Use of two-step self-etch adhesive, prior to restoring cervical cavities with RMGIC, seems to be more efficacious than the conventional cavity conditioner in decreasing marginal microleakage.

  10. Clinical relevance of nine transcriptional molecular markers for the diagnosis of head and neck squamous cell carcinoma in tissue and saliva rinse

    International Nuclear Information System (INIS)

    Lallemant, Benjamin; Hollande, Frédéric; Lallemant, Jean-Gabriel; Lumbroso, Serge; Brouillet, Jean-Paul; Evrard, Alexandre; Combescure, Christophe; Chapuis, Heliette; Chambon, Guillaume; Raynal, Caroline; Reynaud, Christophe; Sabra, Omar; Joubert, Dominique

    2009-01-01

    Analysis of 23 published transcriptome studies allowed us to identify nine genes displaying frequent alterations in HNSCC (FN1, MMP1, PLAU, SPARC, IL1RN, KRT4, KRT13, MAL, and TGM3). We aimed to independently confirm these dysregulations and to identify potential relationships with clinical data for diagnostic, staging and prognostic purposes either at the tissue level or in saliva rinse. For a period of two years, we systematically collected tumor tissue, normal matched mucosa and saliva of patients diagnosed with primary untreated HNSCC. Expression levels of the nine genes of interest were measured by RT-qPCR in tumor and healthy matched mucosa from 46 patients. MMP1 expression level was measured by RT-qPCR in the salivary rinse of 51 HNSCC patients and 18 control cases. Dysregulation of the nine genes was confirmed by the Wilcoxon test. IL1RN, MAL and MMP1 were the most efficient diagnostic markers of HNSCC, with ROC AUC > 0.95 and both sensitivity and specificity above 91%. No clinically relevant correlation was found between gene expression level in tumor and T stage, N stage, tumor grade, global survival or disease-free survival. Our preliminary results suggests that with 100% specificity, MMP1 detection in saliva rinse is potentially useful for non invasive diagnosis of HNSCC of the oral cavity or oropharynx, but technical improvement is needed since sensitivity was only 20%. IL1RN, MAL and MMP1 are prospective tumor diagnostic markers for HNSCC. MMP1 overexpression is the most promising marker, and its detection could help identify tumor cells in tissue or saliva

  11. Soft Plate and Impact Tectonics

    Science.gov (United States)

    Tikoff, Basil

    In the field of tectonics, most of our ideas are published in journals. This is not true of other fields, such as history, in which ideas are primarily published in books. Within my own field of structural geology, I can recall only one book, Strain Fades by E. Hansen (Springer-Verlag, 1971), which presents a new idea in book form. However, even this book is more useful for its philosophical approach and particular methodology of determining directions of folding, than for its overarching idea.Enter Soft Plate and Impact Tectonics, a new book with an interesting hypothesis that has been informally discussed in the geoscience community: A fundamental tenet of plate tectonics is incorrect—namely, that the plates are rigid. This assertion is evident when looking at any mountain range, and is perhaps most clearly stated in Molnar [1988].

  12. Electrolytic treatment of liquid effluents: decontamination by electro coagulation of release water of a petroleum platform; Traitement electrolytique des effluents liquides: decontamination par electrocoagulation des eaux de rejet d'une plate forme petroliere

    Energy Technology Data Exchange (ETDEWEB)

    Nanseu-Njiki, Ch.P.; Ngameni, E.; Poumiba, S. [Yaounde Univ., Laboratoire de Chimie Analytique, Dept. de Chimie Inorganique, Faculte des Sciences (Cameroon); Darchen, A. [Ecole Nationale Superieure de Chimie de Rennes, Laboratoire d' Electrochimie, 35 - Rennes (France)

    2005-07-01

    The water releases of petroleum platforms present lots of pollutants; Usually, these waters are reinjected in ground water when it is possible. In the other cases they are released at the surface and need then a treatment. The electro-coagulation is a suitable method often used. The authors propose to study the optimum conditions of decontamination by this method, by a parametric evaluation (water flow, charge density, ph). Experiments used iron and aluminium electrodes. (A.L.B.)

  13. Teste de microtração em esmalte de um sistema adesivo universal pela técnica etch-and-rinse e etch-and-dry

    OpenAIRE

    Peneque, Carolina Martins Santos

    2014-01-01

    Tese de mestrado, Medicina dentária, Universidade de Lisboa, Faculdade de Medicina Dentária, 2014 Objetivo: Recorrendo ao teste de microtração, avaliar e comparar as forças adesivas em esmalte cortado de um sistema adesivo universal (Scotchbond Universal Adhesive, 3M ESPE, St. Paul, MN, USA) usado segundo as instruções do fabricante, nos modos etch-and-rinse e etch-and-dry. A hipótese nula testada é a de que não existem diferenças estatisticamente significativas nas forças de adesão ao esm...

  14. Remineralization of eroded enamel by a NaF rinse containing a novel calcium phosphate agent in an in situ model: a pilot study

    Directory of Open Access Journals (Sweden)

    Bennett T Amaechi

    2010-08-01

    Full Text Available Bennett T Amaechi1, Ramalingam Karthikeyan1, Poornima K Mensinkai1, Kaveh Najibfard1, Allen C Mackey2, Robert L Karlinsey21University of Texas Health Science Center at San Antonio, San Antonio, Texas, USA; 2Indiana Nanotech, Indianapolis, IN, USAPurpose: An in situ study evaluated the remineralization potential of 225 ppm fluoride (F rinses with and without a calcium phosphate agent (TCP-Si-Ur on eroded enamel.Methods: 20 human patients participated in this IRB approved study. Enamel blocks extracted from 20 human molars were assigned to each of the three study phases (G1, G2, G3. Each block was eroded using 1% citric acid (pH = 2.5, with a slice cut from each block to establish baseline lesion parameters (ie, integrated mineral loss ∆Z, and lesion depth LD using ­transverse microradiography (TMR. Participants and assigned blocks were randomly divided into three 28-day phases. The blocks were mounted into modified orthodontic brackets and bonded to the buccal surface of one of the subject’s mandibular molars. The appliance remained in the ­subject’s mouth for 28 days. Prior to each study phase, participants observed a one-week-washout period using a fluoride-free dentifrice. In each phase, participants brushed with the fluoride-free ­dentifrice for 1 min, followed by one of the following coded treatments: G1: 225 ppm F + 40 ppm ­TCP-Si-Ur rinse (1 min; G2: 225 ppm F rinse (1 min; G3: no rinse (saliva-only. After each phase, appliances were removed and specimens were analyzed using TMR.Results: TMR data (ie, ∆Z and LD revealed all three groups significantly remineralized eroded enamel (paired t-tests, P , 0.001. Net mineralization (% change in ∆Z, LD were as follows (mean (std.dev.: G1: 44.1 (22.6, 30.5 (27.0; G2: 30.0 (7.4, 29.4 (10.5; G3: 23.8 (16.4, 25.7 (15.5. Furthermore, G1 was found to cause significantly more remineralization than G2 (P = 0.039 and G3, (P = 0.002.Conclusion: Mouthrinse containing 225 ppm F plus TCP

  15. Gentilly 2 divider plate replacement

    International Nuclear Information System (INIS)

    Forest, J.; Klisel, E.; McClellan, G.; Schnelder, W.

    1995-01-01

    The steam generators at the Gentilly 2 Nuclear Plant in operation since 1983 were built with primary divider plates of a bolted panel configuration. During a routine outage inspection, it was noted that two bolts had dislodged from the divider and were located lying in the primary head. Subsequent inspections revealed erosion damage to a substantial number of divider plate bolts and to a lesser extent, to the divider plate itself. After further inspection and repair the units were returned to operation, however, it was determined that a permanent replacement of the primary divider plates was going to be necessary. After evaluation of various options, it was decided that the panel type dividers would be replaced with a single piece floating design. The divider itself was to be of a one piece all-welded arrangement to be constructed from individual panels to be brought in through the manways. In view of the strength limitations of the bolted attachment of the upper seat bar to the tubesheet, a new welded seat bar was provided. To counteract erosion concerns, the new divider is fitted with erosion resistant inserts or weld buildup and with improved sealing features in order to minimize leakage and erosion. At an advanced stage in the design and manufacture of the components, the issue of divider strength during LOCA conditions came into focus. Analysis was performed to determine the strength and/or failure characteristics of the divider to a variety of small and large LOCA conditions. The paper describes the diagnosis of the original divider plates and the design, manufacture, field mobilization, installation and subsequent operation of the replacement divider plates. (author)

  16. The effect of plate thickness, surface tension and fluid flow on detachment of drops from a plate

    NARCIS (Netherlands)

    Lexmond, A.S.; Geld, van der C.W.M.; Celata, G.P.

    2004-01-01

    The pinch-off of drops from the downstream end of plates is an important re-entrainment mechanism of condensate in compact condensers. The present experimental study complements a previous one [1], in which ethanol and water drops were created for various mass densities and gas velocities at the

  17. The effect of nutrient media water purity on LIBS based identification of bacteria

    Science.gov (United States)

    Single pulse laser induced breakdown spectroscopy (LIBS) is used as the basis for discrimination between 3 genera of Gram-negative bacteria and 2 genera of gram-positive bacteria representing pathogenic threats commonly found in poultry processing rinse waters. Because LIBS-based discrimination reli...

  18. Two-year water degradation of self-etching adhesives bonded to bur ground enamel

    NARCIS (Netherlands)

    Abdalla, A.I.; Feilzer, A.J.

    2009-01-01

    To evaluate the effect of water storage on the microshear bond strength to ground enamel of three "all-in-one" self-etch adhesives: Futurabond DC, Clearfil S Tri Bond and Hybrid bond; a self-etching primer; Clearfil SE Bond and an etch-and-rinse adhesive system, Admira Bond. Sixty human molars were

  19. Semiclassical theory of plate vibrations

    International Nuclear Information System (INIS)

    Bogomolny, E.; Hugues, E.

    1996-11-01

    The bi-harmonic equation of flexural vibrations of elastic plates is studied by a semiclassical method which can easily be generalized for other models of wave propagation. The surface and perimeter terms of the asymptotic number of levels are derived exactly. The next constant term is also derived. A semiclassical approximation of the quantization condition is obtained. A Berry-Tabor formula and a Gutzwiller trace formula are deduced for the integrable and chaotic cases respectively. From 600 eigenvalues of a clamped stadium plate obtained by a specially developed numerical algorithm, the trace formula is assessed, looking at its Fourier transform compared with the membrane case. (author)

  20. Water

    Directory of Open Access Journals (Sweden)

    E. Sanmuga Priya

    2017-05-01

    Full Text Available Phytoremediation through aquatic macrophytes treatment system (AMATS for the removal of pollutants and contaminants from various natural sources is a well established environmental protection technique. Water hyacinth (Eichhornia crassipes, a worst invasive aquatic weed has been utilised for various research activities over the last few decades. The biosorption capacity of the water hyacinth in minimising various contaminants present in the industrial wastewater is well studied. The present review quotes the literatures related to the biosorption capacity of the water hyacinth in reducing the concentration of dyestuffs, heavy metals and minimising certain other physiochemical parameters like TSS (total suspended solids, TDS (total dissolved solids, COD (chemical oxygen demand and BOD (biological oxygen demand in textile wastewater. Sorption kinetics through various models, factors influencing the biosorption capacity, and role of physical and chemical modifications in the water hyacinth are also discussed.

  1. Circular arc fuel plate stability experiments and analyses for the advanced neutron source

    International Nuclear Information System (INIS)

    Swinson, W.F.; Battiste, R.L.; Yahr, G.T.

    1995-08-01

    The thin fuel plates planned for the Advanced Neutron Source are to be cooled by forcing heavy water at high velocity, 25 m/s, through thin cooling channels on each side of each plate. Because the potential for structural failure of the plates is a design concern, considerable effort has been expended in assessing this potential. As part of this effort, experimental flow tests and analyses to evaluate the structural response of circular arc plates have been conducted, and the results are given in this report

  2. The tectonic plates are moving!

    CERN Document Server

    Livermore, Roy

    2018-01-01

    Written in a witty and informal style, this book explains modern plate tectonics in a non-technical manner, showing not only how it accounts for phenomena such as great earthquakes, tsunamis, and volcanic eruptions, but also how it controls conditions at the Earth’s surface, including global geography and climate, making it suitable for life. The book presents the advances that have been made since the establishment of plate tectonics in the 1960s, highlighting, on the fiftieth anniversary of the theory, the contributions of a small number of scientists who have never been widely recognized for their discoveries. Beginning with the publication of a short article in Nature by Vine and Matthews, the book traces the development of plate tectonics through two generations of the theory. First-generation plate tectonics covers the exciting scientific revolution of the 1960s, its heroes, and its villains. The second generation includes the rapid expansions in sonar, satellite, and seismic technologies during the 1...

  3. License plate recognition using DTCNNs

    NARCIS (Netherlands)

    ter Brugge, M.H; Stevens, J.H; Nijhuis, J.A G; Spaanenburg, L; Tavsanonoglu, V

    1998-01-01

    Automatic license plate recognition requires a series of complex image processing steps. For practical use, the amount of data to he processed must be minimized early on. This paper shows that the computationally most intensive steps can be realized by DTCNNs. Moreover; high-level operations like

  4. Hydroelasticity of a Floating Plate

    DEFF Research Database (Denmark)

    Chen, X.; Jensen, Jørgen Juncher; Cui, W.

    2003-01-01

    The membrane forces are included in the hydroelastic analysis of a floating plate undergoing large vertical deflections in regular monochromatic multidirectional waves. The first-order vertical displacements induced by the linear wave exciting forces are calculated by the mode expansion method in...

  5. Stress state in perforated plates

    International Nuclear Information System (INIS)

    Visner, J.

    1977-01-01

    The method is described of photoelastic measurement of stress concentration factors (s.c.f) in plates perforated by a square, triangular and diagonal grid of circular holes and loaded by uniaxial or biaxial tensile stress. A loading equipment which was developed and its modifications are described. Stress concentration factors found are compared with theoretical and experimental results given in references. (author)

  6. Regulators of growth plate maturation

    NARCIS (Netherlands)

    Emons, Joyce Adriana Mathilde

    2010-01-01

    Estrogen is known to play an important role in longitudinal bone growth and growth plate maturation, but the mechanism by which estrogens exert their effect is not fully understood. In this thesis this role is further explored. Chapter 1 contains a general introduction to longitudinal bone growth

  7. Drying studies of simulated DOE aluminum plate fuels

    International Nuclear Information System (INIS)

    Lords, R.E.; Windes, W.E.; Crepeau, J.C.; Sidwell, R.W.

    1996-01-01

    Experiments have been conducted to validate the Idaho National Engineering Laboratory (INEL) drying procedures for preparation of corroded aluminum plate fuel for dry storage in an existing vented (and filtered) fuel storage facility. A mixture of hydrated aluminum oxide bound with a clay was used to model the aluminum corrosion product and sediment expected in these Department of Energy (DOE) owned fuel types. Previous studies demonstrated that the current drying procedures are adequate for removal of free water inside the storage canister and for transfer of this fuel to a vented dry storage facility. However, using these same drying procedures, the simulated corrosion product was found to be difficult to dry completely from between the aluminum clad plates of the fuel. Another related set of experiments was designed to ensure that the fuel would not be damaged during the drying process. Aluminum plate fuels are susceptible to pitting damage on the cladding that can result in a portion of UAl x fuel meat being disgorged. This would leave a water-filled void beneath the pit in the cladding. The question was whether bursting would occur when water in the void flashes to steam, causing separation of the cladding from the fuel, and/or possible rupture. Aluminum coupons were fabricated to model damaged fuel plates. These coupons do not rupture or sustain any visible damage during credible drying scenarios

  8. Elastic stability of thick auxetic plates

    International Nuclear Information System (INIS)

    Lim, Teik-Cheng

    2014-01-01

    Auxetic materials and structures exhibit a negative Poisson’s ratio while thick plates encounter shear deformation, which is not accounted for in classical plate theory. This paper investigates the effect of a negative Poisson’s ratio on thick plates that are subjected to buckling loads, taking into consideration the shear deformation using Mindlin plate theory. Using a highly accurate shear correction factor that allows for the effect of Poisson’s ratio, the elastic stability of circular and square plates are evaluated in terms of dimensionless parameters, namely the Mindlin-to-Kirchhoff critical buckling load ratio and Mindlin critical buckling load factors. Results for thick square plates reveal that both parameters increase as the Poisson’s ratio becomes more negative. In the case of thick circular plates, the Mindlin-to-Kirchhoff critical buckling load ratios and the Mindlin critical buckling load factors increase and decrease, respectively, as the Poisson’s ratio becomes more negative. The results obtained herein show that thick auxetic plates behave as thin conventional plates, and therefore suggest that the classical plate theory can be used to evaluate the elastic stability of thick plates if the Poisson’s ratio of the plate material is sufficiently negative. The results also suggest that materials with highly negative Poisson’s ratios are recommended for square plates, but not circular plates, that are subjected to buckling loads. (paper)

  9. A radiophotoluminescent glass plate system for medium-sized field dosimetry

    International Nuclear Information System (INIS)

    Nakagawa, Keiichi; Koyanagi, Hiroki; Shiraki, Takashi; Saegusa, Shigeki; Sasaki, Katsutake; Oritate, Takashi; Mima, Kazuo; Miyazawa, Masanori; Ishidoya, Tatsuyo; Ohtomo, Kuni; Yoda, Kiyoshi

    2005-01-01

    A two-dimensional radiophotoluminescent system for medium-sized field dosimetry has been developed using a silver-activated phosphate glass plate with a dimension of 120 mmx120 mmx1 mm and a readout unit comprising a UV excitation lamp and a CCD imager. A dose ranging from 0 to 400 cGy, provided by a 6 MV x-ray beam, was delivered to the glass plate oriented perpendicularly to the beam and positioned in a water phantom at a depth of 10 cm, where the center of the glass plate coincided with the linac isocenter. After the dose delivery, the glass plate was placed in the readout system. The CCD output intensity increased linearly with the applied dose. The angular dependence of response on the direction of radiation incidence was measured by rotating the glass plate in the water phantom, indicating that the output remained constant up to 75 deg. from perpendicular incident direction, followed by a steep reduction down to 85% at an angle of 90 deg. A lateral dose distribution resulting from a 60 mmx60 mm irradiation was compared between the glass plate and an x-ray film having had the same exposure, showing that the glass plate and the x-ray film led to identical dose distributions. The dose reproducibility for a glass plate and the sensitivity variation among different glass plates were also evaluated

  10. On the relative significance of lithospheric weakening mechanisms for sustained plate tectonics

    Science.gov (United States)

    Araceli Sanchez-Maes, Sophia

    2018-01-01

    Plate tectonics requires the bending of strong plates at subduction zones, which is difficult to achieve without a secondary weakening mechanism. Two classes of weakening mechanisms have been proposed for the generation of ongoing plate tectonics, distinguished by whether or not they require water. Here we show that the energy budget of global subduction zones offers a simple yet decisive test on their relative significance. Theoretical studies of mantle convection suggest bending dissipation to occupy only 10-20 % of total dissipation in the mantle, and our results indicate that the hydrous mechanism in the shallow part of plates is essential to satisfy the requirement. Thus, surface oceans are required for the long-term operation of plate tectonics on terrestrial worlds. Establishing this necessary and observable condition for sustained plate tectonics carries important implications for planetary habitability at large.

  11. EFFECT OF AN ADDITIONAL HYDROPHILIC VERSUS HYDROPHOBIC COAT ON THE QUALITY OF DENTINAL SEALING PROVIDED BY TWO-STEP ETCH-AND-RINSE ADHESIVES

    Science.gov (United States)

    Silva, Safira Marques de Andrade; Carrilho, Marcela Rocha de Oliveira; Marquezini, Luiz; Garcia, Fernanda Cristina Pimentel; Manso, Adriana Pigozzo; Alves, Marcelo Corrêa; de Carvalho, Ricardo Marins

    2009-01-01

    Objective: To test the hypothesis that the quality of the dentinal sealing provided by two-step etch-and-rinse adhesives cannot be altered by the addition of an extra layer of the respective adhesive or the application of a more hydrophobic, non-solvated resin. Material and Methods: full-crown preparations were acid-etched with phosphoric acid for 15 s and bonded with Adper Single Bond (3M ESPE), Excite DSC (Ivoclar/Vivadent) or Prime & Bond NT (Dentsply). The adhesives were used according to the manufacturers' instructions (control groups) or after application to dentin they were a) covered with an extra coat of each respective system or b) coated with a non-solvated bonding agent (Adper Scotchbond Multi-Purpose Adhesive, 3M ESPE). Fluid flow rate was measured before and after dentin surfaces were acid-etched and bonded with adhesives. Results: None of the adhesives or experimental treatments was capable to block completely the fluid transudation across the treated dentin. Application of an extra coat of the adhesive did not reduce the fluid flow rate of adhesive-bonded dentin (p>0.05). Conversely, the application of a more hydrophobic non-solvated resin resulted in significant reductions in the fluid flow rate (padhesives. Conclusions: The quality of the dentinal sealing provided by etch-and-rinse adhesives can be significantly improved by the application of a more hydrophobic, non-solvated bonding agent. PMID:19466248

  12. Natural Convective Heat Transfer from Narrow Plates

    CERN Document Server

    Oosthuizen, Patrick H

    2013-01-01

    Natural Convective Heat Transfer from Narrow Plates deals with a heat transfer situation that is of significant practical importance but which is not adequately dealt with in any existing textbooks or in any widely available review papers. The aim of the book is to introduce the reader to recent studies of natural convection from narrow plates including the effects of plate edge conditions, plate inclination, thermal conditions at the plate surface and interaction of the flows over adjacent plates. Both numerical and experimental studies are discussed and correlation equations based on the results of these studies are reviewed.

  13. Capacity limits in columns pulsed with stain steel perforated plates

    International Nuclear Information System (INIS)

    Maset, E.R.; Acosta, E.; Di Piano, M.; Maymo, J.A.

    1987-01-01

    This paper includes part of the second stage of the pulsed columns development program, using a water-nitric acid system as continuous phase and tri-n-butyl phosphate dissolved in kerosene at 30% v/v as disperse phase. Two kits of different geometry perforated plates (different diameter of perforation and free area percentage) were used. Due to the affinity importance of the plates' material with the continuous phase, in all the cases the continuous aqueous phase was used. The relation of flows varied, thus obtaining in each case a curve of characteristic 'flood'. The influence of the geometrical variables, the relation of flows, the medium acidity and the pulse's amplitude was applied in the capacity of the column. Besides, the dimensional correlation of Swift W.H. on the results obtained from 'flood' with both kits of plates to relate flows 1:1 and a minimum deviation was observed. (Author)

  14. Subduction Drive of Plate Tectonics

    Science.gov (United States)

    Hamilton, W. B.

    2003-12-01

    Don Anderson emphasizes that plate tectonics is self-organizing and is driven by subduction, which rights the density inversion generated as oceanic lithosphere forms by cooling of asthenosphere from the top. The following synthesis owes much to many discussions with him. Hinge rollback is the key to kinematics, and, like the rest of actual plate behavior, is incompatible with bottom-up convection drive. Subduction hinges (which are under, not in front of, thin leading parts of arcs and overriding plates) roll back into subducting plates. The Pacific shrinks because bounding hinges roll back into it. Colliding arcs, increasing arc curvatures, back-arc spreading, and advance of small arcs into large plates also require rollback. Forearcs of overriding plates commonly bear basins which preclude shortening of thin plate fronts throughout periods recorded by basin strata (100 Ma for Cretaceous and Paleogene California). This requires subequal rates of advance and rollback, and control of both by subduction. Convergence rate is equal to rates of rollback and advance in many systems but is greater in others. Plate-related circulation probably is closed above 650 km. Despite the popularity of concepts of plumes from, and subduction into, lower mantle, there is no convincing evidence for, and much evidence against, penetration of the 650 in either direction. That barrier not only has a crossing-inhibiting negative Clapeyron slope but also is a compositional boundary between fractionated (not "primitive"), sluggish lower mantle and fertile, mobile upper mantle. Slabs sink more steeply than they dip. Slabs older than about 60 Ma when their subduction began sink to, and lie down on and depress, the 650-km discontinuity, and are overpassed, whereas younger slabs become neutrally buoyant in mid-upper mantle, into which they are mixed as they too are overpassed. Broadside-sinking old slabs push all upper mantle, from base of oceanic lithosphere down to the 650, back under

  15. EMPIRICAL STUDY OF CAR LICENSE PLATES RECOGNITION

    Directory of Open Access Journals (Sweden)

    Nasa Zata Dina

    2015-01-01

    Full Text Available The number of vehicles on the road has increased drastically in recent years. The license plate is an identity card for a vehicle. It can map to the owner and further information about vehicle. License plate information is useful to help traffic management systems. For example, traffic management systems can check for vehicles moving at speeds not permitted by law and can also be installed in parking areas to se-cure the entrance or exit way for vehicles. License plate recognition algorithms have been proposed by many researchers. License plate recognition requires license plate detection, segmentation, and charac-ters recognition. The algorithm detects the position of a license plate and extracts the characters. Various license plate recognition algorithms have been implemented, and each algorithm has its strengths and weaknesses. In this research, I implement three algorithms for detecting license plates, three algorithms for segmenting license plates, and two algorithms for recognizing license plate characters. I evaluate each of these algorithms on the same two datasets, one from Greece and one from Thailand. For detecting li-cense plates, the best result is obtained by a Haar cascade algorithm. After the best result of license plate detection is obtained, for the segmentation part a Laplacian based method has the highest accuracy. Last, the license plate recognition experiment shows that a neural network has better accuracy than other algo-rithm. I summarize and analyze the overall performance of each method for comparison.

  16. Reverse Evolution of Armor Plates in the Threespine Stickleback

    Science.gov (United States)

    Kitano, J.; Bolnick, D.I.; Beauchamp, D.A.; Mazur, M.M.; Mori, S.; Nakano, T.; Peichel, C.L.

    2008-01-01

    Faced with sudden environmental changes, animals must either adapt to novel environments or go extinct. Thus, study of the mechanisms underlying rapid adaptation is crucial not??only for the understanding of natural evolutionary processes but also for the understanding of human-induced evolutionary change, which is an increasingly important problem [1-8]. In the present study, we demonstrate that the frequency of completely plated threespine stickleback fish (Gasterosteus aculeatus) has increased in an urban freshwater lake (Lake Washington, Seattle, Washington) within the last 40 years. This is a dramatic example of "reverse evolution," [9] because the general evolutionary trajectory is toward armor-plate reduction in freshwater sticklebacks [10]. On the basis of our genetic studies and simulations, we propose that the most likely cause of reverse evolution is increased selection for the completely plated morph, which we suggest could result from higher levels of trout predation after a sudden increase in water transparency during the early 1970s. Rapid evolution was facilitated by the existence of standing allelic variation in Ectodysplasin (Eda), the gene that underlies the major plate-morph locus [11]. The Lake Washington stickleback thus provides a novel example of reverse evolution, which is probably caused by a change in allele frequency at the major plate locus in response to a changing predation regime. ?? 2008 Elsevier Ltd. All rights reserved.

  17. Earth's Decelerating Tectonic Plates

    Energy Technology Data Exchange (ETDEWEB)

    Forte, A M; Moucha, R; Rowley, D B; Quere, S; Mitrovica, J X; Simmons, N A; Grand, S P

    2008-08-22

    Space geodetic and oceanic magnetic anomaly constraints on tectonic plate motions are employed to determine a new global map of present-day rates of change of plate velocities. This map shows that Earth's largest plate, the Pacific, is presently decelerating along with several other plates in the Pacific and Indo-Atlantic hemispheres. These plate decelerations contribute to an overall, globally averaged slowdown in tectonic plate speeds. The map of plate decelerations provides new and unique constraints on the dynamics of time-dependent convection in Earth's mantle. We employ a recently developed convection model constrained by seismic, geodynamic and mineral physics data to show that time-dependent changes in mantle buoyancy forces can explain the deceleration of the major plates in the Pacific and Indo-Atlantic hemispheres.

  18. Mathematical methods for elastic plates

    CERN Document Server

    Constanda, Christian

    2014-01-01

    Mathematical models of deformation of elastic plates are used by applied mathematicians and engineers in connection with a wide range of practical applications, from microchip production to the construction of skyscrapers and aircraft. This book employs two important analytic techniques to solve the fundamental boundary value problems for the theory of plates with transverse shear deformation, which offers a more complete picture of the physical process of bending than Kirchhoff’s classical one.   The first method transfers the ellipticity of the governing system to the boundary, leading to singular integral equations on the contour of the domain. These equations, established on the basis of the properties of suitable layer potentials, are then solved in spaces of smooth (Hölder continuous and Hölder continuously differentiable) functions.   The second technique rewrites the differential system in terms of complex variables and fully integrates it, expressing the solution as a combination of complex ana...

  19. PLATE

    DEFF Research Database (Denmark)

    Kling, Joyce; Hjulmand, Lise-Lotte

    2008-01-01

    Copenhagen Business School (CBS) finds itself needing to address the issue of English-medium instruction for its increasing number of foreign exchange and full degree students. With internationalisation as a main pillar of the institution’s agenda, there are concerns whether the teaching faculty...... of academic teaching and lecturing into account....

  20. Electroless metal plating of plastics

    Science.gov (United States)

    Krause, L.J.

    1982-09-20

    Process for plating main group metals on aromatic polymers is carried out by the use of a nonaqueous solution of a salt of an alkali metal in a positive valence state and a main group metal in a negative valence state with contact between the solution and polymer providing a redox reaction causing the deposition of the main group metal and the reduction of the polymer. Products from the process exhibit useful decorative and electrical properties.

  1. A tandem parallel plate analyzer

    International Nuclear Information System (INIS)

    Hamada, Y.; Fujisawa, A.; Iguchi, H.; Nishizawa, A.; Kawasumi, Y.

    1996-11-01

    By a new modification of a parallel plate analyzer the second-order focus is obtained in an arbitrary injection angle. This kind of an analyzer with a small injection angle will have an advantage of small operational voltage, compared to the Proca and Green analyzer where the injection angle is 30 degrees. Thus, the newly proposed analyzer will be very useful for the precise energy measurement of high energy particles in MeV range. (author)

  2. Curved Folded Plate Timber Structures

    OpenAIRE

    Buri, Hans Ulrich; Stotz, Ivo; Weinand, Yves

    2011-01-01

    This work investigates the development of a Curved Origami Prototype made with timber panels. In the last fifteen years the timber industry has developed new, large size, timber panels. Composition and dimensions of these panels and the possibility of milling them with Computer Numerical Controlled machines shows great potential for folded plate structures. To generate the form of these structures we were inspired by Origami, the Japanese art of paper folding. Common paper tessellations are c...

  3. PRETREATING URANIUM FOR METAL PLATING

    Science.gov (United States)

    Wehrmann, R.F.

    1961-05-01

    A process is given for anodically treating the surface of uranium articles, prior to metal plating. The metal is electrolyzed in an aqueous solution of about 10% polycarboxylic acid, preferably oxalic acid, from 1 to 5% by weight of glycerine and from 1 to 5% by weight of hydrochloric acid at from 20 to 75 deg C for from 30 seconds to 15 minutes. A current density of from 60 to 100 amperes per square foot is used.

  4. Embedded adhesive connection for laminated glass plates

    DEFF Research Database (Denmark)

    Hansen, Jens Zangenberg; Poulsen, S.H.; Bagger, A.

    2012-01-01

    The structural behavior of a new connection design, the embedded adhesive connection, used for laminated glass plates is investigated. The connection consists of an aluminum plate encapsulated in-between two adjacent triple layered laminated glass plates. Fastening between glass and aluminum...... usage in a design situation. The embedded connection shows promising potential as a future fastening system for load-carrying laminated glass plates....

  5. Modified tubularized incised plate urethroplasty

    Directory of Open Access Journals (Sweden)

    Shivaji Mane

    2013-01-01

    Full Text Available Aim: To share our experience of doing tubularized incised plate urethroplasty with modifications. Materials and Methods: This is a single surgeon personal series from 2004 to 2009. One hundred patients of distal hypospadias were subjected for Snodgrass urethroplasty with preputioplasty. The age range was 1 to 5 year with mean age of 2.7 years. Selection criteria were good urethral plate, without chordee and torsion needing complete degloving. Main technical modification from original Snodgrass procedure was spongioplasty, preputioplasty, and dorsal slit when inability to retract prepuce during surgery. Results: Average follow-up period is 23 months. Seven (7% patients developed fistula and one patient had complete preputial dehiscence. Phimosis developed in three (3% patients and required circumcision. Dorsal slit was required in seven patients. One patient developed meatal stenosis in postoperative period. All other patients are passing single urinary stream and have cosmesis that is acceptable. Conclusions: Modified tubularized incised plate urethroplasty with preputioplasty effectively gives cosmetically normal looking penis with low complications.

  6. Divertor plate for thermonuclear reactor

    International Nuclear Information System (INIS)

    Yamazaki, Seiichiro; Sato, Keisuke; Nishio, Satoshi.

    1993-01-01

    In a divertor plate for a thermonuclear reactor, adjacent cooling pipes are electrically insulated from each other and pipes made of a gradient functional material prepared by compositing ceramics having an insulation property and metals are metallurgically joined to at least one portion of each of the cooling pipes. Electric current caused upon occurrence of plasma disruption is interrupted by the insulation portion, so that a large circuit is not formed and electromagnetic force is decreased to such a extent that the divertor plate is not ruptured. Since a header of the cooling pipes can be installed at any optional position, the installation space can be reduced. Further, since inlet and exit collection headers can be disposed on both ends of the cooling pipes, it is possible to shorten the length of the cooling pipe of the divertor plate corresponded to high heat fluxes and reduce the pressure loss on the side of coolants to about 1/2. Further, turn back portions of small radius of curvature of the cooling pipes are eliminated to reduce the cost and extend the lifetime and, in addition, protection tiles can be attached easily. (N.H.)

  7. Progress in thermomechanical control of steel plates and their commercialization

    Science.gov (United States)

    Nishioka, Kiyoshi; Ichikawa, Kazutoshi

    2012-01-01

    The water-cooled thermomechanical control process (TMCP) is a technology for improving the strength and toughness of water-cooled steel plates, while allowing control of the microstructure, phase transformation and rolling. This review describes metallurgical aspects of the microalloying of steel, such as niobium addition, and discusses advantages of TMCP, for example, in terms of weldability, which is reduced upon alloying. Other covered topics include the development of equipment, distortions in steel plates, peripheral technologies such as steel making and casting, and theoretical modeling, as well as the history of property control in steel plate production and some early TMCP technologies. We provide some of the latest examples of applications of TMCP steel in various industries such as shipbuilding, offshore structures, building construction, bridges, pipelines, penstocks and cryogenic tanks. This review also introduces high heat-affected-zone toughness technologies, wherein the microstructure of steel is improved by the addition of fine particles of magnesium-containing sulfides and magnesium- or calcium-containing oxides. We demonstrate that thanks to ongoing developments TMCP has the potential to meet the ever-increasing demands of steel plates. PMID:27877477

  8. Progress in thermomechanical control of steel plates and their commercialization

    Directory of Open Access Journals (Sweden)

    Kiyoshi Nishioka and Kazutoshi Ichikawa

    2012-01-01

    Full Text Available The water-cooled thermomechanical control process (TMCP is a technology for improving the strength and toughness of water-cooled steel plates, while allowing control of the microstructure, phase transformation and rolling. This review describes metallurgical aspects of the microalloying of steel, such as niobium addition, and discusses advantages of TMCP, for example, in terms of weldability, which is reduced upon alloying. Other covered topics include the development of equipment, distortions in steel plates, peripheral technologies such as steel making and casting, and theoretical modeling, as well as the history of property control in steel plate production and some early TMCP technologies. We provide some of the latest examples of applications of TMCP steel in various industries such as shipbuilding, offshore structures, building construction, bridges, pipelines, penstocks and cryogenic tanks. This review also introduces high heat-affected-zone toughness technologies, wherein the microstructure of steel is improved by the addition of fine particles of magnesium-containing sulfides and magnesium- or calcium-containing oxides. We demonstrate that thanks to ongoing developments TMCP has the potential to meet the ever-increasing demands of steel plates.

  9. Secure matching of Dutch car license plates

    NARCIS (Netherlands)

    Sunil, A.B.; Erkiny, Z.; Veugenyz, T.

    2016-01-01

    License plate matching plays an important role in applications like law enforcement, traffic management and road pricing, where the plate is first recognized and then compared to a database of authorized vehicle registration plates. Unfortunately, there are several privacy related issues that should

  10. Moving Divertor Plates in a Tokamak

    International Nuclear Information System (INIS)

    Zweben, S.J.; Zhang, H.

    2009-01-01

    Moving divertor plates could help solve some of the problems of the tokamak divertor through mechanical ingenuity rather than plasma physics. These plates would be passively heated on each pass through the tokamak and cooled and reprocessed outside the tokamak. There are many design options using varying plate shapes, orientations, motions, coatings, and compositions

  11. Designing a licence plate for memorability

    NARCIS (Netherlands)

    Schraagen, J.M.C.; Dongen, C.J.G. van

    2005-01-01

    Good memorability of licence plates is important in those cases where licence plates are viewed for a brief period of time and the information is essential for police investigations. The purpose of the current study was to design a new Dutch licence plate that could be remembered well. A memory

  12. Strength of Ship Plates under Combined Loading

    DEFF Research Database (Denmark)

    Cui, W.; Wang, Y.; Pedersen, Preben Terndrup

    2002-01-01

    Strength of ship plates plays a significant role in the ultimate strength analysis of ship structures. In recent years several authors have proposed simplified analytical methods to calculate the ultimate strength of unstiffened plates. The majority of these investigations deal with plates subjec...

  13. Strength of ship plates under combined loading

    DEFF Research Database (Denmark)

    Cui, Weiching; Wang, Yongjun; Pedersen, Preben Terndrup

    2000-01-01

    Strength of ship plates plays a significant role for the ultimate strength analysis of ship structures. In recent years several authors have proposed simplified methods to calculate the ultimate strength of unstiffened plates. The majority of these investigations deal with plates subjected to lon...

  14. Operational test of bonded magnetocaloric plates

    DEFF Research Database (Denmark)

    Bahl, Christian; Navickaité, Kristina; Neves Bez, Henrique

    2017-01-01

    Bonded plates made by hot pressing La0.85Ce0.15Fe11.25Mn0.25Si1.5Hy particles and resin have been tested as active magnetic regenerators in a small scale magnetocaloric device. Firstly the plates were carefully characterised magnetically and thermally. The plates were prepared with 5 wt% resin...

  15. Moving Divertor Plates in a Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    S.J. Zweben, H. Zhang

    2009-02-12

    Moving divertor plates could help solve some of the problems of the tokamak divertor through mechanical ingenuity rather than plasma physics. These plates would be passively heated on each pass through the tokamak and cooled and reprocessed outside the tokamak. There are many design options using varying plate shapes, orientations, motions, coatings, and compositions.

  16. Preheating Water In The Covers Of Solar Water Heaters

    Science.gov (United States)

    Bhandari, Pradeep

    1995-01-01

    Solar water heaters that include glass covers over absorber plates redesigned to increase efficiencies according to proposal. Redesign includes modification of single-layer glass cover into double-layer glass cover and addition of plumbing so cool water to be heated made to flow between layers of cover before entering absorber plate.

  17. Pseudo-Outbreak of Cupriavidus pauculus Infection at an Outpatient Clinic Related to Rinsing Culturette Swabs in Tap Water▿

    Science.gov (United States)

    Balada-Llasat, Joan-Miquel; Elkins, Camille; Swyers, Lettie; Bannerman, Tammy; Pancholi, Preeti

    2010-01-01

    Cupriavidus pauculus is a water microorganism rarely isolated from clinical specimens. We describe a pseudo-outbreak in which multiple strains that were associated with moistening of culturette swabs with tap water were isolated from a single clinic before collecting the patient specimen. PMID:20444965

  18. Pseudo-Outbreak of Cupriavidus pauculus Infection at an Outpatient Clinic Related to Rinsing Culturette Swabs in Tap Water▿

    OpenAIRE

    Balada-Llasat, Joan-Miquel; Elkins, Camille; Swyers, Lettie; Bannerman, Tammy; Pancholi, Preeti

    2010-01-01

    Cupriavidus pauculus is a water microorganism rarely isolated from clinical specimens. We describe a pseudo-outbreak in which multiple strains that were associated with moistening of culturette swabs with tap water were isolated from a single clinic before collecting the patient specimen.

  19. Evaluation of TECRA broth, Bolton broth, and direct plating for recovery of Campylobacter spp, from broiler carcass rinsates from commercial processing plants.

    Science.gov (United States)

    Richardson, L J; Cox, N A; Bailey, J S; Berrang, M E; Cox, J M; Buhr, R J; Fedorka-Cray, P J; Harrison, M A

    2009-05-01

    The purpose of this study was to compare a conventional culture broth method (Bolton enrichment), a newly developed proprietary broth method (TECRA Campylobacter enrichment), and direct plating for recovery of Campylobacter spp. from chicken carcass rinsates. Whole carcass rinses were taken from 140 carcasses at rehang (immediately after defeathering but before evisceration) and from 140 carcasses at postchill from eight different processing plants in the United States. The rinsate samples were packed in ice and shipped overnight to the laboratory. Aliquots of the rinsate were transferred into Bolton and TECRA enrichment broths and were direct plated. Standard laboratory procedures with Campy-cefex plates were followed for recovery of Campylobacter spp. For rehang carcasses, 94% were positive for Campylobacter spp. with the TECRA enrichment broth and 74% were positive with the Bolton enrichment broth. For postchill carcasses, 74% were positive for Campylobacter spp. with the TECRA enrichment broth and 71% were positive with the Bolton enrichment broth. Compared with the Bolton enrichment broth, TECRA enrichment broth significantly suppressed non-Campylobacter microflora (P < 0.05). Overall, TECRA enrichment broth yielded an 11% higher total number of Campylobacter-positive samples compared with the Bolton enrichment broth. Campylobacter spp. detection in postchill samples was significantly greater (P < 0.05) by enrichment (84%) than by direct plating (19%). The high number of Campylobacter-positive samples obtained with all procedures indicated that 99% of the carcass rinsates obtained at rehang and 84% obtained at postchill contained Campylobacter spp.

  20. Experimental Study of an SWH System with V-Shaped Plate

    Directory of Open Access Journals (Sweden)

    Jalaluddin

    2016-05-01

    Full Text Available Solar energy is known as an environmentally friendly energy source with a wide range of applications. This energy can be utilized in various applications such as domestic and industrial water heating using solar water heating (SWH systems. The thermal performance of an SWH system using a V-shaped absorber plate is presented in this study. Two SWH systems with different absorber plates, i.e. a flat-plate and a V-shaped plate, have been investigated experimentally. First, the absorptivity of the absorber plates was calculated analytically. The optimum V-shaped configuration with angle at β = 21° (V-shaped dimensions t = 4 cm and l = 4 cm was determined from various V-shaped plate absorbers based on their absorptivity and applied in the experimental study. Two SWH systems were installed and tested at a low flowrate of 0.5 L/min and at a high flowrate of 2 L/min. The results showed that the SWH system with V-shaped plate absorber had a 3.6-4.4% better performance compared with that of the system with flat-plate absorber.

  1. EFFECT OF RINSING SOLUTIONS FOR REMOVING MANCOZEB RESIDUES IN TABLE TOMATOES EFEITO DE SOLUÇÕES DE ENXÁGUE NA REMOÇÃO DE RESÍDUOS DE MANCOZEB EM TOMATES DE MESA

    Directory of Open Access Journals (Sweden)

    Míriam Fontes Araujo Silveira

    2009-12-01

    Full Text Available

    Fungicides are the pesticides most widely used for tomato cultivation, mainly dithiocarbamates. The objective of this research was to study the efficiency of dithiocarbamate mancozeb removal from table tomatoes, through rinsing processes. Analyses of tomato acidity, brix, water activity, pH, and manganese content were carried out. After rinsing tomatoes with drinking water and solutions of vinegar (made from alcohol, sodium bicarbonate, and dihidrated sodium dichloroisocyanurate, mancozeb levels were assessed in skin and whole fruit, by quantifying the manganese content present in the samples. It was observed that the rinsing processes reduced significantly the amount of residues in the tomatoes. The reduction of mancozeb was higher in the skin, where it can be found in its highest concentration. Treatments using drinking water and sodium bicarbonate solution removed over 61% of the residues present in tomatoes skin.

    KEY-WORDS: Fungicides; dithiocarbamates; Lycopersicum esculentum Mill.

    Achievement report for fiscal 1998. Development of an industrial rinsing equipment of environmentally harmonizing type using an ultra critical fluid (the second year); 1998 nendo seika hokokusho. Chorinkai ryutai wo mochiita kankyo chowagata kogyo senjo sochi no kaihatsu (dai 2 nendo)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    This project is intended for environment friendly and pollution-free rinsing by using an ultra critical fluid of CO2 being an atmospheric constituent. It also has a purpose of establishing a new rinsing method implemented by an ultra precision component machine and device using such features possessed by the ultra critical fluid as high permeability and disinfecting activities. It is further intended of developing, fabricating, and practically using a rinsing equipment that makes possible precision rinsing of mechanical, electronic, optical and aeronautical components. Using the results of experiments performed in the previous year as the base, discussions were given on the relationship between the two aspects of the hardware aspect such as equipment configuration and piping of the rinsing equipment and the software aspect such as operating conditions and procedures and the rising effect. As a result, a new rinsing equipment of solvent circulation type was proposed. The basic design software for the specific equipment was completed, and an experimental equipment was designed and fabricated under the clean specifications. The performance evaluation and verification experiments were finished in the end of fiscal 1998, and collection of fundamental data has begun. With regard to the rinsing evaluation method, qualitative and quantitative analyses were performed on the rinsing by using a surface shape measuring microscope and the infrared spectroscopy. (NEDO)

  2. Experimental investigation of the unsteady one-phase flow through perforated plates

    International Nuclear Information System (INIS)

    Casadei, F.

    1982-07-01

    The flow of the coolant through the perforated dip-plate during a hypothetical core-disruptive accident in a sodium-cooled fast breeder reactor was simulated in a one-dimensional model. Several experiments with water as fluid and with various perforation ratios of the dip-plate and different initial heights of the fluid head over the dip plate were run. The pressure drop through the dip-plate and the forces acting on the dip-plate and on the upper plug of the reactor vessel in a wide range of the Reynolds and Strouhal numbers were measured. The flow pattern downstreams the perforated plate was filmed with high-speed cameras. The resistance coefficients for the unsteady flow of the coolant through the perforated plate were obtained as a function of the acceleration. The forces acting on the upper plug and their time integral were compared with those acting on the dip-plate. Finally, using the high-speed film pictures the formation of fluid jets downstream the dip-plate was investigated. (orig.) [de

  3. Evaluation of Thin Plate Hydrodynamic Stability through a Combined Numerical Modeling and Experimental Effort

    Energy Technology Data Exchange (ETDEWEB)

    Tentner, A. [Argonne National Lab. (ANL), Argonne, IL (United States); Bojanowski, C. [Argonne National Lab. (ANL), Argonne, IL (United States); Feldman, E. [Argonne National Lab. (ANL), Argonne, IL (United States); Wilson, E. [Argonne National Lab. (ANL), Argonne, IL (United States); Solbrekken, G [Univ. of Missouri, Columbia, MO (United States); Jesse, C. [Univ. of Missouri, Columbia, MO (United States); Kennedy, J. [Univ. of Missouri, Columbia, MO (United States); Rivers, J. [Univ. of Missouri, Columbia, MO (United States); Schnieders, G. [Univ. of Missouri, Columbia, MO (United States)

    2017-05-01

    An experimental and computational effort was undertaken in order to evaluate the capability of the fluid-structure interaction (FSI) simulation tools to describe the deflection of a Missouri University Research Reactor (MURR) fuel element plate redesigned for conversion to lowenriched uranium (LEU) fuel due to hydrodynamic forces. Experiments involving both flat plates and curved plates were conducted in a water flow test loop located at the University of Missouri (MU), at conditions and geometries that can be related to the MURR LEU fuel element. A wider channel gap on one side of the test plate, and a narrower on the other represent the differences that could be encountered in a MURR element due to allowed fabrication variability. The difference in the channel gaps leads to a pressure differential across the plate, leading to plate deflection. The induced plate deflection the pressure difference induces in the plate was measured at specified locations using a laser measurement technique. High fidelity 3-D simulations of the experiments were performed at MU using the computational fluid dynamics code STAR-CCM+ coupled with the structural mechanics code ABAQUS. Independent simulations of the experiments were performed at Argonne National Laboratory (ANL) using the STAR-CCM+ code and its built-in structural mechanics solver. The simulation results obtained at MU and ANL were compared with the corresponding measured plate deflections.

  4. Free vibration analysis of corroded steel plates

    Energy Technology Data Exchange (ETDEWEB)

    Eslami-Majd, Alireza; Rahbar-Ranji, Ahmad [AmirKabir University of Technology, Tehran (Iran, Islamic Republic of)

    2014-06-15

    Vibration analysis of unstiffened/stiffened plates has long been studied due to its importance in the design and condition assessments of ship and offshore structures. Corrosion is inevitable in steel structures and has been so far considered in strength analysis of structures. We studied the free vibration of pitted corroded plates with simply supported boundary conditions. Finite element analysis, with ABAQUS, was used to determine the natural frequencies and mode shapes of corroded plates. Influential parameters including plate aspect ratio, degree of pit, one-sided/both-sided corroded plate, and different corrosion patterns were investigated. By increasing the degree of corrosion, reduction of natural frequency increases. Plate aspect ratio and plate dimensions have no influence on reduction of natural frequency. Different corrosion patterns on the surface of one-sided corroded plates have little influence on reduction of natural frequency. Ratio of pit depth over plate thickness has no influence on the reduction of natural frequency. The reduction of natural frequency in both-sided corroded plates is higher than one-sided corroded plates with the same amount of total corrosion loss. Mode shapes of vibration would change due to corrosion, except square mode shapes.

  5. METHOD OF MAKING AND PLATE CONNECTION

    Science.gov (United States)

    Patriarca, P.; Shubert, C.E.; Slaughter, G.M.

    1963-02-26

    This invention relates to a method of joining, by welding or brazing, a tube to a plate, particularly where the tube and the plate are of different thickness or have different thermal conductivities and are subject to high temperatures. In this method the tube is inserted in the core of a plate containing an annular groove in its back face concentric with the bore and in communication with the bore. One end of the tube is welded substantially flush with the front end of the plate. Brazing alloy is placed in the groove on the back face of the plate and heat is applied to the plate and tube to melt the brazing alloy to permit the alloy to flow into the bore and bond the tube to the plate. (AEC)

  6. PWR integral tie plate and locking mechanism

    International Nuclear Information System (INIS)

    Flora, B.S.; Osborne, J.L.

    1980-01-01

    A locking mechanism for securing an upper tie plate to the tie rods of a nuclear fuel bundle is described. The mechanism includes an upper tie plate assembly and locking sleeves fixed to the ends of the tie rods. The tie plate is part of the upper tie plate assembly and is secured to the fuel bundle by securing the entire upper tie plate assembly to the locking sleeves fixed to the tie rods. The assembly includes, in addition to the tie plate, locking nuts for engaging the locking sleeves, retaining sleeves to operably connect the locking nuts to the assembly, a spring biased reaction plate to restrain the locking nuts in the locked position and a means to facilitate the removal of the entire assembly as a unit from the fuel bundle

  7. Effects of fixed orthodontic treatment and two new mouth rinses on gingival health: A prospective cohort followed by a single-blind placebo-controlled randomized clinical trial.

    Science.gov (United States)

    Sobouti, Farhad; Rakhshan, Vahid; Heydari, Mohaddeseh; Keikavusi, Shohreh; Dadgar, Sepideh; Shariati, Mahsa

    2018-03-01

    Routine brushing protocols might not suffice to reduce the increased plaque accumulation in orthodontic patients. Antimicrobial mouth rinses are favorable in this regard. This two-phase study evaluated the effects of orthodontic treatment and the application of two mouthwashes not studied before on oral health indices. In this two-phase study (a prospective cohort followed by a parallel randomized controlled trial), plaque index (PI), gingival index (GI), gingival bleeding index (GBI), and pocket probing depth (PPD) were measured in 54 orthodontic patients before orthodontic treatment and 4 months later. Then patients were randomized into three groups of mouthrinses: Persica (herbal), Ortho-Kin (containing diluted chlorhexidine), and Placebo (n=18×3). The effects of orthodontic treatment and mouthrinses were analyzed statistically (α=0.05). All the 4 indices increased between the baseline and 4th month of treatment (P values<0.01, paired t-test). They decreased back to baseline levels or below them, after one month of mouthwash application (P values<0.002). Both mouthwashes showed therapeutic effects compared to placebo in terms of PI and GBI. In the case of GI, only Persica showed significantly better results compared to placebo. Regarding PPD, only Ortho-Kin acted better than placebo (P values≤0.05, Tukey). Lack of positive control (regular chlorhexidine mouth rinse) and negative control (a group with no mouthwashes, even without the placebo). Lack of sample size predetermination based on a priori power calculations. The difference between the regime of Persica with that of Ortho-Kin and placebo (which had similar application protocols) disallowed perfectly effective blinding of the patients (hence, single-blind). Fixed orthodontic treatment might disrupt gingival health. Antimicrobial mouthwashes might reverse this. Both evaluated mouthwashes might have therapeutic effects. Copyright © 2018 CEO. Published by Elsevier Masson SAS. All rights reserved.

  8. Evaluation of HPV-16 and HPV-18 specific antibody measurements in saliva collected in oral rinses and merocel® sponges.

    Science.gov (United States)

    Parker, Katherine H; Kemp, Troy J; Pan, Yuanji; Yang, Zhen; Giuliano, Anna R; Pinto, Ligia A

    2018-05-03

    Current Human papillomavirus (HPV) L1 VLP vaccines protect against HPV-16 and HPV-18-associated cancers, in females and males. Although correlates of protection have not been identified, HPV-specific antibodies at sites of infection are thought to be the main mechanism of protection afforded by vaccination. Oral sampling has gained increased attention as a potential alternative to serum in monitoring immunity to vaccination and understanding local immunity in oral cancers. Serum was collected via venipuncture, and saliva was collected via oral rinses and Merocel® sponges from healthy volunteers: 16 unvaccinated females, 6 females (ages 24-41) and 6 mid-adult aged males (ages 27-45) recipients of three doses of the HPV-16/18/6/11 vaccine (Gardasil®). Mid-adult male vaccine trial participants were compared to female participants. Samples were tested for anti-HPV-16 and anti-HPV-18 immunoglobulin G levels by an L1 virus-like particle-based enzyme-linked immunosorbent assay (ELISA). All vaccinated participants had detectable serum anti-HPV-16 and anti-HPV-18 antibodies. Optimal standard concentration range and sample serial dilutions for oral rinses were determined. The standard curve was not affected by the type of solution examined. Reproducibility of HPV-16 and HPV-18 antibody titers in mouthwash (overall CV  0.9) was observed for sera spiked controls in both solutions. HPV-16 and HPV-18 specific antibodies were detectable in saliva from vaccine recipients, both in mouthwash and in Merocel® sponges but levels were several logs lower than those in serum. This study confirms the application of HPV-16 and HPV-18 ELISAs currently used in sero-epidemiological studies of immunogenicity of HPV vaccines for use with oral samples. Oral samples may be a useful resource for the detection of HPV-16 and HPV-18-specific antibodies in saliva following vaccination. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Effect of dentin biomodifiers on the immediate and long-term bond strengths of a simplified etch and rinse adhesive to dentin.

    Science.gov (United States)

    Singh, Payal; Nagpal, Rajni; Singh, Udai Pratap

    2017-08-01

    This in vitro study evaluated the effect of dentin biomodifiers on the immediate and long-term bond strengths of a simplified etch and rinse adhesive to dentin. Flat coronal dentin surfaces were prepared in 120 extracted human molars. Teeth were randomly divided into 5 groups ( n = 24) according to 5 different surface pre-treatments: No pre-treatment (control); 1M carbodiimide (EDC); 0.1% epigallocatechin-3-gallate (EGCG); 2% minocycline (MI); 10% sodium ascorbate (SA). After surface pre-treatment, adhesive (Adper Single Bond 2 [SB], 3M ESPE) was applied. Composite was applied into transparent plastic tubes (2.5 mm in diameter), which was placed over the bonded dentin surface. From each group, 10 samples were subjected to shear bond strength (SBS) evaluation at 24 hours (immediate) and remaining 10 samples were tested after 6 months (delayed). Additionally, 4 samples per group were subjected to scanning electron microscopic analysis for observation of resin-dentin interface. The data were statistically analysed with Shaperio‑Wilk W test, 2-way analysis of variance (ANOVA), and post hoc Tukey's test. At 24 hours, SBS of all surface pre-treatment groups were comparable with the control group, with significant differences found between EDC and SA groups only ( p = 0.009). After 6 months storage, EDC, EGCG, and MI pre-treatments preserved the resin-dentin bond strength with no significant fall. Dentin pre-treatment with all the dentin biomodifiers except SA resulted in significant preservation of resin-dentin bond over 6 months storage period, without negatively affecting the immediate bond strength of the etch and rinse adhesive tested.

  10. Microtensile bond strength of etch-and-rinse and self-etching adhesives to intrapulpal dentin after endodontic irrigation and setting of root canal sealer.

    Science.gov (United States)

    Wattanawongpitak, Nipaporn; Nakajima, Masatoshi; Ikeda, Masaomi; Foxton, Richard M; Tagami, Junji

    2009-02-01

    To evaluate the effect of endodontic irrigation regimens and calcium hydroxide root canal sealer (Sealapex) on the microtensile bond strengths (muTBS) of dual-curing resin composite (Clearfil DC Core Automix) to the intrapulpal dentin. Forty standardized coronal-half root canal dentin specimens obtained from human premolars were divided into 4 groups: group A, no treatment (control); group B, Sealapex; group C, NaOCl/Sealapex; group D, EDTA/NaOCl/Sealapex. After 7 days of storage in 100% relative humidity, Sealapex was removed. Dentin surfaces were bonded with adhesives, either etch-and-rinse (Single Bond) or self-etching (Clearfil SE Bond), and built up with resin composite. The bonded specimens were trimmed into an hourglass shape with a 1-mm2 cross-sectional area for microtensile testing (n = 20). The muTBS to intrapulpal dentin was analyzed using two-way ANOVA and Dunnett's TC test. Two teeth of each group were prepared for micromorphological analysis of dentin surface. The root canal sealer with or without endodontic irrigation significantly affected the bond strengths of resin composite to intrapulpal dentin compared with the control group (p 0.05). The dentin surface was covered with a mud-like material after sealer application for 7 days. The root canal sealer reduced the muTBS of dual-curing resin composite with etch-and-rinse and self-etching adhesive systems to intrapulpal dentin. Treatment with EDTA followed by NaOCI prior to obturation caused an additional reduction in muTBS of both adhesive systems to intrapulpal dentin.

  11. Effect of dentin biomodifiers on the immediate and long-term bond strengths of a simplified etch and rinse adhesive to dentin

    Directory of Open Access Journals (Sweden)

    Payal Singh

    2017-07-01

    Full Text Available Objectives This in vitro study evaluated the effect of dentin biomodifiers on the immediate and long-term bond strengths of a simplified etch and rinse adhesive to dentin. Materials and Methods Flat coronal dentin surfaces were prepared in 120 extracted human molars. Teeth were randomly divided into 5 groups (n = 24 according to 5 different surface pre-treatments: No pre-treatment (control; 1M carbodiimide (EDC; 0.1% epigallocatechin-3-gallate (EGCG; 2% minocycline (MI; 10% sodium ascorbate (SA. After surface pre-treatment, adhesive (Adper Single Bond 2 [SB], 3M ESPE was applied. Composite was applied into transparent plastic tubes (2.5 mm in diameter, which was placed over the bonded dentin surface. From each group, 10 samples were subjected to shear bond strength (SBS evaluation at 24 hours (immediate and remaining 10 samples were tested after 6 months (delayed. Additionally, 4 samples per group were subjected to scanning electron microscopic analysis for observation of resin-dentin interface. The data were statistically analysed with Shaperio‑Wilk W test, 2-way analysis of variance (ANOVA, and post hoc Tukey's test. Results At 24 hours, SBS of all surface pre-treatment groups were comparable with the control group, with significant differences found between EDC and SA groups only (p = 0.009. After 6 months storage, EDC, EGCG, and MI pre-treatments preserved the resin-dentin bond strength with no significant fall. Conclusions Dentin pre-treatment with all the dentin biomodifiers except SA resulted in significant preservation of resin-dentin bond over 6 months storage period, without negatively affecting the immediate bond strength of the etch and rinse adhesive tested.

  12. Cleaning IBL secondary sludge in the tubular plate steam generators

    International Nuclear Information System (INIS)

    Montoro de Frutos, E.; Gonzalez Carballo, S.

    2012-01-01

    After cleanings Sludge Lancing using 250bar made from the center lane, identifies an area of solidified remaining sludge on the tube plate. Since late 2010, IBERDROLA-SAVAC has developed Inner System Bundle Lancing (IBL), which locally involves shooting a jet of water at high pressure 590bar directly impacting sludge areas within the tube bundle hard to detach and break into small pieces that can be extracted from GV through a closed circuit suction.

  13. The effectiveness of a saline mouth rinse regimen and education programme on radiation-induced oral mucositis and quality of life in oral cavity cancer patients: A randomised controlled trial.

    Science.gov (United States)

    Huang, B-S; Wu, S-C; Lin, C-Y; Fan, K-H; Chang, J T-C; Chen, S-C

    2018-03-01

    Radiation therapy (RT) and concurrent chemotherapy RT (CCRT) generate radiation-induced oral mucositis (OM) and lower quality of life (QOL). This study assessed the impact of a saline mouth rinse regimen and education programme on radiation-induced OM symptoms, and QOL in oral cavity cancer (OCC) patients receiving RT or CCRT. Ninety-one OCC patients were randomly divided into a group that received saline mouth rinses and an education programme and a control group that received standard care. OM symptoms and QOL were assessed with the WHO Oral Toxicity Scale, MSS-moo and UW-QOL. Data were collected at the first postoperative visit to the radiation department (T0) and at 4 weeks and 8 weeks after beginning RT or CCRT. Patients in both groups had significantly higher levels of physical and social-emotional QOL at 8 weeks after beginning RT or CCRT compared to the first visit. Patients in the saline rinse group had significantly better physical and social-emotional QOL as compared to the standard care group at 8 weeks. Radiation-induced OM symptoms and overall QOL were not different between the groups. We thus conclude the saline rinse and education programme promote better physical and social-emotional QOL in OCC patients receiving RT/CCRT. © 2018 John Wiley & Sons Ltd.

  14. Four-year clinical evaluation of Class II nano-hybrid resin composite restorations bonded with a one-step self-etch and a two-step etch-and-rinse adhesive

    DEFF Research Database (Denmark)

    van Dijken, Jan W V; Pallesen, Ulla

    2011-01-01

    The objective of this prospective clinical trial was to evaluate the 4-year clinical performance of an ormocer-based nano-hybrid resin composite (Ceram X; Dentsply/DeTrey) in Class II restorations placed with a one-step self-etch (Xeno III; Dentsply/DeTrey) and two-step etch-and-rinse adhesive (I...

  15. Vortex Dynamics around Pitching Plates

    Science.gov (United States)

    2014-04-29

    electrical signals are A/D converted in an ATI NetBox interface and recorded using a Java application, and are filtered in three steps. The first is a low...the plate while staying attached to the corners of the leading edge. During this process, a second vortex loop, created by the quick angular ...is a spike in CL centered around t = 0 due to non-circulatory6 effects from the angular acceleration of the wing. The amplitude of the peak is

  16. Micro plate fission chamber development

    International Nuclear Information System (INIS)

    Wang Mei; Wen Zhongwei; Lin Jufang; Jiang Li; Liu Rong; Wang Dalun

    2014-01-01

    To conduct the measurement of neutron flux and the fission rate distribution at several position in assemblies, the micro plate fission chamber was designed and fabricated. Since the requirement of smaller volume and less structure material was taken into consideration, it is convinient, commercial and practical to use fission chamber to measure neutron flux in specific condition. In this paper, the structure of fission chamber and process of fabrication were introduced and performance test result was presented. The detection efficiency is 91.7%. (authors)

  17. Non-cyanide silver plating

    International Nuclear Information System (INIS)

    Dini, J.W.

    1995-01-01

    Lawrence Livermore National Laboratory (LLNL) and Technic, Inc. have entered into a CRADA (Cooperative Research and Development Agreement) with the goal of providing industry with an environmentally benign alternative to the presently used silver cyanide plating process. This project has been in place for about six months and results are quite promising. The main objective, that of deposition of deposits as thick as 125 um (5 mils), has been met. Property data such as stress and hardness have been obtained and the structure of the deposit has been analyzed via metallography and x-ray diffraction. These results will be presented in this paper, along with plans for future work

  18. Technical Note: Scanning of parallel-plate ionization chamber and diamond detector for measurements of water-dose profiles in the vicinity of a narrow x-ray microbeam.

    Science.gov (United States)

    Nariyama, Nobuteru

    2017-12-01

    Scanning of dosimeters facilitates dose distribution measurements with fine spatial resolutions. This paper presents a method of conversion of the scanning results to water-dose profiles and provides an experimental verification. An Advanced Markus chamber and a diamond detector were scanned at a resolution of 6 μm near the beam edges during irradiation with a 25-μm-wide white narrow x-ray beam from a synchrotron radiation source. For comparison, GafChromic films HD-810 and HD-V2 were also irradiated. The conversion procedure for the water dose values was simulated with Monte Carlo photon-electron transport code as a function of the x-ray incidence position. This method was deduced from nonstandard beam reference-dosimetry protocols used for high-energy x-rays. Among the calculated nonstandard beam correction factors, P wall , which is the ratio of the absorbed dose in the sensitive volume of the chamber with water wall to that with a polymethyl methacrylate wall, was found to be the most influential correction factor in most conditions. The total correction factor ranged from 1.7 to 2.7 for the Advanced Markus chamber and from 1.15 to 1.86 for the diamond detector as a function of the x-ray incidence position. The water dose values obtained with the Advanced Markus chamber and the HD-810 film were in agreement in the vicinity of the beam, within 35% and 18% for the upper and lower sides of the beam respectively. The beam width obtained from the diamond detector was greater, and the doses out of the beam were smaller than the doses of the others. The comparison between the Advanced Markus chamber and HD-810 revealed that the dose obtained with the scanned chamber could be converted to the water dose around the beam by applying nonstandard beam reference-dosimetry protocols. © 2017 American Association of Physicists in Medicine.

  19. Electroless nickel-plating for the PWSCC mitigation of nickel-base alloys in nuclear power plants

    International Nuclear Information System (INIS)

    Kim, Ji Hyun; Hwang, Il Soon

    2008-01-01

    The feasibility study has been performed as an effort to apply the electroless nickel-plating method for a proposed countermeasure to mitigate primary water stress corrosion cracking (PWSCC) of nickel-base alloys in nuclear power plants. In order to understand the corrosion behavior of nickel-plating at high temperature water, the electrochemical properties of electroless nickel-plated alloy 600 specimens exposed to simulated pressurized water reactor (PWR) primary water were experimentally characterized in high temperature and high pressure water condition. And, the resistance to the flow accelerated corrosion (FAC) test was investigated to check the durability of plated layers in high-velocity water-flowing environment at high temperature. The plated surfaces were examined by using both scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) after exposures to the condition. From this study, it is found that the corrosion resistance of electroless nickel-plated Alloy 600 is higher than that of electrolytic plating in 290 deg. C water