WorldWideScience

Sample records for plates reader systems

  1. 78 FR 59065 - Interview Room Recording System Standard and License Plate Reader Standard Workshops

    Science.gov (United States)

    2013-09-25

    ... DEPARTMENT OF JUSTICE Office of Justice Programs [OJP (NIJ) Docket No. 1632] Interview Room..., Department of Justice. ACTION: Notice of the Interview Room Recording System Standard and License Plate... performance standards for Interview Room Recording Systems and License Plate Readers used by criminal justice...

  2. PC-based car license plate reader

    Science.gov (United States)

    Hwang, Chung-Mu; Shu, Shyh-Yeong; Chen, Wen-Yu; Chen, Yie-Wern; Wen, Kuang-Pu

    1992-11-01

    A car license plate reader (CLPR) using fuzzy inference and neural network algorithm has been developed in Industrial Technology Research Institute (ITRI) and installed in highway toll stations to identify stolen cars. It takes an average of 0.7 seconds to recognize a car license plate by using a PC with 80486-50 CPU. The recognition rate of the system is about 97%. The techniques of CLPR include vehicle sensing, image grab control, optic pre- processing, lighting, and optic character recognition (OCR). The CLPR can be used in vehicle flow statistics, the checking of stolen vehicles, automatic charging systems in parking lots or garage management, and so on.

  3. Caveats and limitations of plate reader-based high-throughput kinetic measurements of intracellular calcium levels

    International Nuclear Information System (INIS)

    Heusinkveld, Harm J.; Westerink, Remco H.S.

    2011-01-01

    Calcium plays a crucial role in virtually all cellular processes, including neurotransmission. The intracellular Ca 2+ concentration ([Ca 2+ ] i ) is therefore an important readout in neurotoxicological and neuropharmacological studies. Consequently, there is an increasing demand for high-throughput measurements of [Ca 2+ ] i , e.g. using multi-well microplate readers, in hazard characterization, human risk assessment and drug development. However, changes in [Ca 2+ ] i are highly dynamic, thereby creating challenges for high-throughput measurements. Nonetheless, several protocols are now available for real-time kinetic measurement of [Ca 2+ ] i in plate reader systems, though the results of such plate reader-based measurements have been questioned. In view of the increasing use of plate reader systems for measurements of [Ca 2+ ] i a careful evaluation of current technologies is warranted. We therefore performed an extensive set of experiments, using two cell lines (PC12 and B35) and two fluorescent calcium-sensitive dyes (Fluo-4 and Fura-2), for comparison of a linear plate reader system with single cell fluorescence microscopy. Our data demonstrate that the use of plate reader systems for high-throughput real-time kinetic measurements of [Ca 2+ ] i is associated with many pitfalls and limitations, including erroneous sustained increases in fluorescence, limited sensitivity and lack of single cell resolution. Additionally, our data demonstrate that probenecid, which is often used to prevent dye leakage, effectively inhibits the depolarization-evoked increase in [Ca 2+ ] i . Overall, the data indicate that the use of current plate reader-based strategies for high-throughput real-time kinetic measurements of [Ca 2+ ] i is associated with caveats and limitations that require further investigation. - Research highlights: → The use of plate readers for high-throughput screening of intracellular Ca 2+ is associated with many pitfalls and limitations. → Single cell

  4. Use of a Fluorometric Imaging Plate Reader in high-throughput screening

    Science.gov (United States)

    Groebe, Duncan R.; Gopalakrishnan, Sujatha; Hahn, Holly; Warrior, Usha; Traphagen, Linda; Burns, David J.

    1999-04-01

    High-throughput screening (HTS) efforts at Abbott Laboratories have been greatly facilitated by the use of a Fluorometric Imaging Plate Reader. The FLIPR consists of an incubated cabinet with integrated 96-channel pipettor and fluorometer. An argon laser is used to excite fluorophores in a 96-well microtiter plate and the emitted fluorometer. An argon laser is used to excite fluorophores in a 96-well microtiter plate and the emitted fluorescence is imaged by a cooled CCD camera. The image data is downloaded from the camera and processed to average the signal form each well of the microtiter pate for each time point. The data is presented in real time on the computer screen, facilitating interpretation and trouble-shooting. In addition to fluorescence, the camera can also detect luminescence form firefly luciferase.

  5. High-throughput and automated diagnosis of antimicrobial resistance using a cost-effective cellphone-based micro-plate reader

    Science.gov (United States)

    Feng, Steve; Tseng, Derek; di Carlo, Dino; Garner, Omai B.; Ozcan, Aydogan

    2016-12-01

    Routine antimicrobial susceptibility testing (AST) can prevent deaths due to bacteria and reduce the spread of multi-drug-resistance, but cannot be regularly performed in resource-limited-settings due to technological challenges, high-costs, and lack of trained professionals. We demonstrate an automated and cost-effective cellphone-based 96-well microtiter-plate (MTP) reader, capable of performing AST without the need for trained diagnosticians. Our system includes a 3D-printed smartphone attachment that holds and illuminates the MTP using a light-emitting-diode array. An inexpensive optical fiber-array enables the capture of the transmitted light of each well through the smartphone camera. A custom-designed application sends the captured image to a server to automatically determine well-turbidity, with results returned to the smartphone in ~1 minute. We tested this mobile-reader using MTPs prepared with 17 antibiotics targeting Gram-negative bacteria on clinical isolates of Klebsiella pneumoniae, containing highly-resistant antimicrobial profiles. Using 78 patient isolate test-plates, we demonstrated that our mobile-reader meets the FDA-defined AST criteria, with a well-turbidity detection accuracy of 98.21%, minimum-inhibitory-concentration accuracy of 95.12%, and a drug-susceptibility interpretation accuracy of 99.23%, with no very major errors. This mobile-reader could eliminate the need for trained diagnosticians to perform AST, reduce the cost-barrier for routine testing, and assist in spatio-temporal tracking of bacterial resistance.

  6. Evaluation of the Minnesota Easy Culture System II Bi-Plate and Tri-Plate for identification of common mastitis pathogens in milk.

    Science.gov (United States)

    Royster, E; Godden, S; Goulart, D; Dahlke, A; Rapnicki, P; Timmerman, J

    2014-01-01

    The objective of this study was to validate use of the Minnesota Easy Culture System II Bi-Plate and Tri-Plate (University of Minnesota Laboratory for Udder Health, St. Paul) to identify common mastitis pathogens in milk. A total of 283 quarter and composite milk samples submitted to the University of Minnesota Laboratory for Udder Health during the spring of 2010 were cultured simultaneously using 3 methods: standard laboratory culture (reference method) and the Minnesota Easy Culture System II Bi-Plate and Tri-Plate methods. Bi-Plate and Tri-Plate cultures were incubated for 18 to 24h and interpreted by 2 independent, untrained readers within 5h of each other. An experienced technician completed the standard laboratory culture. For each sample, all 3 study personnel recorded the culture result (yes/no) for each of the following diagnostic categories: no bacterial growth (NG), mixed (2 organisms), contaminated (3 or more organisms), gram-positive (GP), gram-negative (GN), Staphylococcus spp., Streptococcus spp., Streptococcus agalactiae, Streptococcus dysgalactiae, Streptococcus uberis, Enterococcus spp., Staphylococcus aureus, coagulase-negative staphylococci, Escherichia coli, Klebsiella spp., and other. For each category, the prevalence, sensitivity, specificity, accuracy, and predictive values of a positive and negative test were calculated, and the agreement between readers and between each reader and the laboratory was assessed. Specificity, overall accuracy, and negative predictive values were generally high (>80%) for the Bi-Plate and Tri-Plate for each category. Sensitivity and positive predictive values were intermediate (>60%) or high (>80%) for the broad categories of NG, GP, GN, Staphylococcus spp. and Streptococcus spp., and for Staph. aureus, but were generally lower (negative predictive value for Streptococcus spp., and higher interreader agreement for some of the more specific categories. Our conclusion was that Bi-Plate and Tri-Plate results will

  7. Performance of a thermal neutron radiographic system using imaging plates

    International Nuclear Information System (INIS)

    Silvani, Maria Ines; Almeida, Gevaldo L. de; Furieri, Rosanne; Lopes, Ricardo T.

    2009-01-01

    A performance evaluation of a neutron radiographic system equipped with a thermal neutron sensitive imaging plate has been undertaken. It includes the assessment of spatial resolution, linearity, dynamic range and the response to exposure time, as well as a comparison of these parameters with the equivalent ones for neutron radiography employing conventional films and a gadolinium foil as converter. The evaluation and comparison between the radiographic systems have been performed at the Instituto de Engenharia Nuclear - CNEN, using the Argonauta Reactor as source of thermal neutrons and a commercially available imaging plate reader. (author)

  8. The use of BAS-TR imaging plates calibration in determining the resolving power of Fuji BAS-1800II image plate reader

    Science.gov (United States)

    Alnaimi, R.

    2018-01-01

    The importance of this work lies in assuring the reliability of the results obtained from both imaging plates type BAS-TR and Fuji Image Reader BAS-1800II as they are widely used in calculating essential x-ray sources parameters such as the source size, x-ray flux and brilliance, hence, the calibration presented in this work. For such quantitative analysis, a common practice used by many researchers, where Gold resolution meshes are utilised for such purpose, however not quite successful due to the transmission effect of high energy photons at their edges as well as the pixeling effect while magnifying the scanned image to secure the edge spread function (ESF) data. In contrast, the use of resolution test target (RTT) and wire mesh grid together with a set of test samples i.e. Stanley blades, Ta, Ti and Si wafer of 100, 300, 15, and 490 micron thickness respectively appeared to be efficient in determining IP pixel size and the resolution of the reader. Two different experiments were conducted using two different targets and lasers of very different performance. The first, was a 15 μm VHS video tape composed of Mylar as carrier film with Fe2O3 and CrO2 powder. Nd:YAG laser of long pulse 800 ps, 50 Hz repetition rate and single shot were utilised. Whereas, the second experiment were conducted on a 9μm C wire and a short pulse 500fs Cerberus single shot laser was used. The results obtained from both experiments were pretty much similar. The imaging plate spatial resolution was measured to be: 3.4 ± 0.2 pixels and a pixel size of 41.26 ± 1.4 μm, whereas the smallest resolvable object visible to the reader (1:1 imaging with magnification factor) was of order 140.3 ± 0.3 microns. This appeared to be worse by a factor of three which indicates the importance of the reader's calibration on a regular basis, and at the same time one has to reconsider any related work and calculation based upon the previous nominal values.

  9. An automated wide-field time-gated optically sectioning fluorescence lifetime imaging multiwell plate reader for high-content analysis of protein-protein interactions

    Science.gov (United States)

    Alibhai, Dominic; Kumar, Sunil; Kelly, Douglas; Warren, Sean; Alexandrov, Yuriy; Munro, Ian; McGinty, James; Talbot, Clifford; Murray, Edward J.; Stuhmeier, Frank; Neil, Mark A. A.; Dunsby, Chris; French, Paul M. W.

    2011-03-01

    We describe an optically-sectioned FLIM multiwell plate reader that combines Nipkow microscopy with wide-field time-gated FLIM, and its application to high content analysis of FRET. The system acquires sectioned FLIM images in fluorescent protein. It has been applied to study the formation of immature HIV virus like particles (VLPs) in live cells by monitoring Gag-Gag protein interactions using FLIM FRET of HIV-1 Gag transfected with CFP or YFP. VLP formation results in FRET between closely packed Gag proteins, as confirmed by our FLIM analysis that includes automatic image segmentation.

  10. Development of LEDs-based microplate reader for bioanalytical assay measurements

    International Nuclear Information System (INIS)

    Alaruri, Sami D; Katzlinger, Michael; Schinwald, Bernhard; Kronberger, Georg; Atzler, Joseph

    2013-01-01

    The optical design for an LEDs-based microplate reader that can perform fluorescence intensity (top and bottom), absorbance, luminescence and time-resolved fluorescence measurements is described. The microplate reader is the first microplate reader in the marketplace that incorporates LEDs as excitation light sources. Absorbance measurements over the 0–3.5 optical density range for caffeine solution are presented. Additionally, fluorescence intensity readings collected at 535 and 625 nm from a green and a red RediPlate TM are reported. Furthermore, fluorescence decay lifetime measurements obtained for Eu (europium) and Sm (samarium) standard solutions using 370 nm excitation are presented. The microplate reader detection limits for the fluorescence intensity top, fluorescence intensity bottom, fluorescence polarization and time-resolved fluorescence modes are 1.5 fmol 100 µL −1 fluorescein (384-well plate), 25 fmol 100 µL −1 fluorescein (384-well plate), 5 mP at 10 nM fluorescein (black 384-well plate) and 30 amol 100 µL −1 europium solution (white 384-well plate), respectively. (paper)

  11. Development of LEDs-based microplate reader for bioanalytical assay measurements

    Science.gov (United States)

    Alaruri, Sami D.; Katzlinger, Michael; Schinwald, Bernhard; Kronberger, Georg; Atzler, Joseph

    2013-10-01

    The optical design for an LEDs-based microplate reader that can perform fluorescence intensity (top and bottom), absorbance, luminescence and time-resolved fluorescence measurements is described. The microplate reader is the first microplate reader in the marketplace that incorporates LEDs as excitation light sources. Absorbance measurements over the 0-3.5 optical density range for caffeine solution are presented. Additionally, fluorescence intensity readings collected at 535 and 625 nm from a green and a red RediPlateTM are reported. Furthermore, fluorescence decay lifetime measurements obtained for Eu (europium) and Sm (samarium) standard solutions using 370 nm excitation are presented. The microplate reader detection limits for the fluorescence intensity top, fluorescence intensity bottom, fluorescence polarization and time-resolved fluorescence modes are 1.5 fmol 100 µL-1 fluorescein (384-well plate), 25 fmol 100 µL-1 fluorescein (384-well plate), 5 mP at 10 nM fluorescein (black 384-well plate) and 30 amol 100 µL-1 europium solution (white 384-well plate), respectively.

  12. Dependence of fading patterns of photo-stimulated luminescence from imaging plates on radiation, energy, and image reader

    International Nuclear Information System (INIS)

    Ohuchi, H.; Yamadera, A.

    2002-01-01

    We have been investigating the fading characteristics of imaging plates (IPs) as integral type detectors. The dependence on alpha, beta, and gamma ray radiation and their energies of the fading effect was measured using three types of IPs (BAS-UR, BAS-TR, and BAS-MS). The functions to correct the fading were determined by using the method reported in a previous paper. In all types of IPs, we confirmed that the fading effect is independent of the energy of the incident particles of beta and gamma rays and also independent of radiation except for the first component, which fades out in a very short time after irradiation with alpha rays. These results are very useful in the utilization of IPs as integral detectors in practical radiation fields. Empirically, the fading pattern is known to change when the IP is scanned by different types of image readers. The differences in the fading patterns obtained with two types of image readers, the BAS-1000 and the BAS-5000 (Fuji Film Co.), is discussed. Development of an equation for correcting the effects of the differences in the image readers was attempted

  13. Development of optically stimulated luminescence reader systems in BARC

    International Nuclear Information System (INIS)

    Kulkarni, M.S.

    2008-01-01

    BARC has very vast experience in the development of thermoluminescence (TL) reader systems both for routine personnel monitoring and research application. However, optically stimulated luminescence (OSL) related instrumentation is a recent development in BARC. The increasing popularity of OSL technique in the radiation dosimetry applications in the recent past has driven investigation and developmental programme in the OSL measurement facilities at BARC. As the consequence of the efforts directed towards the indigenous development of OSL reader system, OSL readers with various readout modes like continuous wave (CW) OSL mode, linear intensity modulated OSL (LM-OSL), pulsed OSL (POSL) have been developed. In addition to these conventional modes of operation a novel non-linear OSL mode (NL-OSL) has also been developed for the OSL measurements. This paper reviews the details of the development of OSL reader system including experience with high intensity blue/green LED stimulation light source and detection system. Also discussed are recently developed versatile integrated TL/OSL reader systems for TL and OSL measurements. (author)

  14. The automated Risoe TL dating reader system

    International Nuclear Information System (INIS)

    Boetter-Jensen, L.

    1988-01-01

    The features of the new modified Riso TL dating reader system are described. A vacuum chamber that accommodates the entire 24-position sample changer unit has been designed. The vacuum and N 2 -gas functions are software-controlled. A newly designed heater system is capable of repeated heating cycles to 700 0 C. The sample changer system accommodates fine-grain discs as well as planchettes for coarse grains. Two software-controlled beta irradiators can be attached to the reader, e.g. for predose measurement. The software allows a user without programming expertise to create any desired measuring sequence, and to store and recall data and glow curves for making analyses. (author)

  15. Establishing a cellular FRET-based fluorescence plate reader assay to monitor proNGF-induced cross-linking of sortilin and the neurotrophin receptor p75(NTR)

    DEFF Research Database (Denmark)

    Skeldal, Sune; Kjaergaard, Maj M; Alwasel, Saleh

    2015-01-01

    the vps10p domain receptor sortilin and the neurotrophin receptor p75(NTR). However, proNGF-induced receptor complex formation has been difficult to directly assess other than by western blotting. We here describe a fluorescence resonance energy transfer (FRET) based fluorescence plate reader assay...

  16. Paper microzone plates.

    Science.gov (United States)

    Carrilho, Emanuel; Phillips, Scott T; Vella, Sarah J; Martinez, Andres W; Whitesides, George M

    2009-08-01

    This paper describes 96- and 384-microzone plates fabricated in paper as alternatives to conventional multiwell plates fabricated in molded polymers. Paper-based plates are functionally related to plastic well plates, but they offer new capabilities. For example, paper-microzone plates are thin (approximately 180 microm), require small volumes of sample (5 microL per zone), and can be manufactured from inexpensive materials ($0.05 per plate). The paper-based plates are fabricated by patterning sheets of paper, using photolithography, into hydrophilic zones surrounded by hydrophobic polymeric barriers. This photolithography used an inexpensive formulation photoresist that allows rapid (approximately 15 min) prototyping of paper-based plates. These plates are compatible with conventional microplate readers for quantitative absorbance and fluorescence measurements. The limit of detection per zone loaded for fluorescence was 125 fmol for fluorescein isothiocyanate-labeled bovine serum albumin, and this level corresponds to 0.02 the quantity of analyte per well used to achieve comparable signal-to-noise in a 96-well plastic plate (using a solution of 25 nM labeled protein). The limits of detection for absorbance on paper was approximately 50 pmol per zone for both Coomassie Brilliant Blue and Amaranth dyes; these values were 0.4 that required for the plastic plate. Demonstration of quantitative colorimetric correlations using a scanner or camera to image the zones and to measure the intensity of color, makes it possible to conduct assays without a microplate reader.

  17. Geometric Distribution-Based Readers Scheduling Optimization Algorithm Using Artificial Immune System

    Directory of Open Access Journals (Sweden)

    Litian Duan

    2016-11-01

    Full Text Available In the multiple-reader environment (MRE of radio frequency identification (RFID system, multiple readers are often scheduled to interrogate the randomized tags via operating at different time slots or frequency channels to decrease the signal interferences. Based on this, a Geometric Distribution-based Multiple-reader Scheduling Optimization Algorithm using Artificial Immune System (GD-MRSOA-AIS is proposed to fairly and optimally schedule the readers operating from the viewpoint of resource allocations. GD-MRSOA-AIS is composed of two parts, where a geometric distribution function combined with the fairness consideration is first introduced to generate the feasible scheduling schemes for reader operation. After that, artificial immune system (including immune clone, immune mutation and immune suppression quickly optimize these feasible ones as the optimal scheduling scheme to ensure that readers are fairly operating with larger effective interrogation range and lower interferences. Compared with the state-of-the-art algorithm, the simulation results indicate that GD-MRSOA-AIS could efficiently schedules the multiple readers operating with a fairer resource allocation scheme, performing in larger effective interrogation range.

  18. Enzyme activity deviates due to spatial and temporal temperature profiles in commercial microtiter plate readers.

    Science.gov (United States)

    Grosch, Jan-Hendrik; Sieben, Michaela; Lattermann, Clemens; Kauffmann, Kira; Büchs, Jochen; Spieß, Antje C

    2016-03-01

    Microtiter plates (MTP) and automatized techniques are increasingly applied in the field of biotechnology. However, the susceptibility of MTPs to edge effects such as thermal gradients can lead to high variation of measured enzyme activities. In an effort to enhance experimental reliability, to quantify, and to minimize instrument-caused deviations in enzyme kinetics between two MTP-readers, we comprehensively quantified temperature distribution in 96-well MTPs. We demonstrated the robust application of the absorbance dye cresol red as easily applicable temperature indicator in cuvettes and MTPs and determined its accuracy to ±0.16°C. We then quantified temperature distributions in 96-well MTPs revealing temperature deviations over single MTP of up to 2.2°C and different patterns in two commercial devices (BioTek Synergy 4 and Synergy Mx). The obtained liquid temperature was shown to be substantially controlled by evaporation. The temperature-induced enzyme activity variation within MTPs amounted to about 20 %. Activity deviations between MTPs and to those in cuvettes were determined to 40 % due to deviations from the set temperature in MTPs. In conclusion, we propose a better control of experimental conditions in MTPs or alternative experimental systems for reliable determination of kinetic parameters for bioprocess development. Copyright © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Students Attendance Management System Based On RFID And Fingerprint Reader

    Directory of Open Access Journals (Sweden)

    Moth Moth Myint Thein

    2015-07-01

    Full Text Available Abstract Today students class attendance is become more important part for any organizationsinstitutions. The conventional method of taking attendance by calling names or signing on paper is very time consuming and insecure hence inefficient. This paper presents the manual students attendance management into computerized system for convenience or data reliability. So the system is developed by the integration of ubiquitous computing systems into classroom for managing the students attendance using RFID and fingerprint reader. The system is designed to implement an attendance management system based on RFID and fingerprint reader which students need to use their student identification card ID and their finger ID to success the attendance where only authentic student can be recorded the attendance during the class. In this system passive RFID tag and reader pairs are used to register the student ID cards individually and fingerprint reader is used for attendance. This system takes attendance electronically with the help of the RFID and finger print device and the records of the attendance are stored in a database. Students roll call percentages and their details are easily seenvia Graphical User Interface GUI. This system will have the required databases for students attendance teachers subjects and students details. This application is implemented by Microsoft Visual Studio and Microsoft SQL Server as IDE. C language is used to implement this system.

  20. Microcomputer-Controlled Reader Systems for Archaeological and Geological TL Dating

    DEFF Research Database (Denmark)

    Bøtter-Jensen, Lars; Mejdahl, V.

    1984-01-01

    Two fully automated TL reader systems for TL dating and a manually operated reader for research purpose were put into operation during 1982-3. All systems are controlled by HP-85 or HP-86 microcomputers; thus flexibility in selection of measurement parameters, calculation of TL signals and displa...... the archaeological and geological ages. The principle of the measurement procedures are described, and dating results are presented to illustrate the performance of the systems...

  1. A TLD reader for wide range in situ dose measurement

    International Nuclear Information System (INIS)

    Deme, S; Apathy, I.; Bodnar, L.; Csoeke, A.; Hejja, I.

    1998-01-01

    A portable thermoluminescent dosemeter reader suitable for reading at the site of exposure is described. The instrument consists of a glass bulb containing the CaSO 4 :Dy thermoluminescent material laminated to the surface of an electrically heated resistive metal plate. The bulb is encapsulated in a cylindrical, pen-like metal holder made of aluminium. A one-wire-port integrated electronic programmable memory chip mounted inside the holder contains the identification code and the individual calibration parameters of the dosemeter. The aperture of the holder is normally covered by a stainless steel tube to protect the bulb from light and mechanical shocks. The tube slips backwards automatically when the dosemeter is inserted into the reader. The system is used by the Hungarian nuclear power plant. (M.D.)

  2. Light transmission aggregometry using pre-coated microtiter plates and a Victor X5 plate reader

    DEFF Research Database (Denmark)

    Vinholt, Pernille Just; Nybo, Mads; Nielsen, Camilla Brødsgaard

    2017-01-01

    Background Light transmission aggregometry (LTA) can be performed with microtiter plates (96-well LTA). When conducting LTA, an agonist is added to platelet-rich plasma and the sample is shaken for minutes after which absorbance readings are done. Platelet aggregation is detected as decrease...... in absorbance. However, the classical method is cumbersome and therefore microtiter plates can be used for concomitant testing of multiple samples. Furthermore, it would be convenient to prepare the plate in advance of platelet aggregation testing. Aim: The aim of the present study was to establish a simplified...

  3. Low Access Delay Anti-Collision Algorithm for Reader in RFID systems

    DEFF Research Database (Denmark)

    Galiotto, Carlo; Marchetti, Nicola; Prasad, Neeli R.

    2010-01-01

    Radio Frequency Identification (RFID) is a technology which is spreading more and more as a medium to identify, locate and track assets through the productive chain. As all the wireless communication devices sharing the same transmission channel, RFID readers and tags experience collisions whenever...... deployed over the same area. In this work, the RFID reader collision problem is studied and a centralized scheduling-based algorithm is proposed as possible candidate solution, especially for those scenarios involving static or low mobility readers. Taking into account the circuitry limitations of the tags......, which do not allow to use frequency or code division multiple access schemes in the RFID systems, this paper proposes an algorithm aiming to prevent the readers collisions, while keeping the access delay of the readers to the channel possibly low. The simulation results show that this algorithm performs...

  4. Development Of The Drexler Optical-Card Reader/Writer System

    Science.gov (United States)

    Pierce, Gerald A.

    1988-06-01

    An optical-card reader/writer optical and electronic breadboard system, developed by SRI International under contract to Drexler Technology, is described. The optical card, which is the same size as a credit card, can contain more than 2 megabytes of digital user data, which may also include preformatted tracking information and preformatted data. The data layout on the card is similar to that on a floppy disk, with each track containing a header and clocking information. The design of this optical reader/writer system for optical cards is explained. Design of the optical card system entails a number of unique issues: To accommodate both laser-recorded and mass-duplicated information, the system must be compatible with preencoded information, which implies a larger-than-normal spot size (5 gm) and a detection system that can read both types of optical patterns. Cost-reduction considerations led to selection of a birefringent protection layer, which dictated a nonstandard optical system. The non-polarization-sensitive optics use an off-axis approach to detection. An LED illumination system makes it possible to read multiple tracks.

  5. Natural Convective Heat Transfer from Narrow Plates

    CERN Document Server

    Oosthuizen, Patrick H

    2013-01-01

    Natural Convective Heat Transfer from Narrow Plates deals with a heat transfer situation that is of significant practical importance but which is not adequately dealt with in any existing textbooks or in any widely available review papers. The aim of the book is to introduce the reader to recent studies of natural convection from narrow plates including the effects of plate edge conditions, plate inclination, thermal conditions at the plate surface and interaction of the flows over adjacent plates. Both numerical and experimental studies are discussed and correlation equations based on the results of these studies are reviewed.

  6. Entrance C - New Automatic Number Plate Recognition System

    CERN Multimedia

    2013-01-01

    Entrance C (Satigny) is now equipped with a latest-generation Automatic Number Plate Recognition (ANPR) system and a fast-action road gate.   During the month of August, Entrance C will be continuously open from 7.00 a.m. to 7.00 p.m. (working days only). The security guards will open the gate as usual from 7.00 a.m. to 9.00 a.m. and from 5.00 p.m. to 7.00 p.m. For the rest of the working day (9.00 a.m. to 5.00 p.m.) the gate will operate automatically. Please observe the following points:       Stop at the STOP sign on the ground     Position yourself next to the card reader for optimal recognition     Motorcyclists must use their CERN card     Cyclists may not activate the gate and should use the bicycle turnstile     Keep a safe distance from the vehicle in front of you   If access is denied, please check that your vehicle regist...

  7. Voltage-current characteristics of a pin-plate system with different plate configurations

    International Nuclear Information System (INIS)

    Feng, Zhuangbo; Long, Zhengwei

    2013-01-01

    In this paper, the voltage-current (V-I) characteristics of a pin-plate system with four types of collection plate configurations are studied experimentally. The collection plates consider a single metal plate, a metal plate with a fly ash cake layer, a metal plate with a clean filter media and a metal plate with a dirty filter media. The results show that the clean filter media has no obvious effect on the V-I characteristics. But the dirty filter media reduces the current density because of its high resistance. The thick fly ash cake layer increase current density because of the anti-corona effect but the increment is not very obvious.

  8. Development of Plate Reader and On-Line Microfluidic Screening to Identify Ligands of the 5-Hydroxytryptamine Binding Protein in Venoms

    Directory of Open Access Journals (Sweden)

    Reka A. Otvos

    2015-06-01

    Full Text Available The 5-HT3 receptor is a ligand-gated ion channel, which is expressed in the nervous system. Its antagonists are used clinically for treatment of postoperative- and radiotherapy-induced emesis and irritable bowel syndrome. In order to better understand the structure and function of the 5-HT3 receptor, and to allow for compound screening at this receptor, recently a serotonin binding protein (5HTBP was engineered with the Acetylcholine Binding Protein as template. In this study, a fluorescence enhancement assay for 5HTBP ligands was developed in plate-reader format and subsequently used in an on-line microfluidic format. Both assay types were validated using an existing radioligand binding assay. The on-line microfluidic assay was coupled to HPLC via a post-column split which allowed parallel coupling to a mass spectrometer to collect MS data. This high-resolution screening (HRS system is well suitable for compound mixture analysis. As a proof of principle, the venoms of Dendroapsis polylepis, Pseudonaja affinis and Pseudonaja inframacula snakes were screened and the accurate masses of the found bioactives were established. To demonstrate the subsequent workflow towards structural identification of bioactive proteins and peptides, the partial amino acid sequence of one of the bioactives from the Pseudonaja affinis venom was determined using a bottom-up proteomics approach.

  9. An MILP-Based Cross-Layer Optimization for a Multi-Reader Arbitration in the UHF RFID System

    Science.gov (United States)

    Choi, Jinchul; Lee, Chaewoo

    2011-01-01

    In RFID systems, the performance of each reader such as interrogation range and tag recognition rate may suffer from interferences from other readers. Since the reader interference can be mitigated by output signal power control, spectral and/or temporal separation among readers, the system performance depends on how to adapt the various reader arbitration metrics such as time, frequency, and output power to the system environment. However, complexity and difficulty of the optimization problem increase with respect to the variety of the arbitration metrics. Thus, most proposals in previous study have been suggested to primarily prevent the reader collision with consideration of one or two arbitration metrics. In this paper, we propose a novel cross-layer optimization design based on the concept of combining time division, frequency division, and power control not only to solve the reader interference problem, but also to achieve the multiple objectives such as minimum interrogation delay, maximum reader utilization, and energy efficiency. Based on the priority of the multiple objectives, our cross-layer design optimizes the system sequentially by means of the mixed-integer linear programming. In spite of the multi-stage optimization, the optimization design is formulated as a concise single mathematical form by properly assigning a weight to each objective. Numerical results demonstrate the effectiveness of the proposed optimization design. PMID:22163743

  10. An MILP-Based Cross-Layer Optimization for a Multi-Reader Arbitration in the UHF RFID System

    Directory of Open Access Journals (Sweden)

    Chaewoo Lee

    2011-02-01

    Full Text Available In RFID systems, the performance of each reader such as interrogation range and tag recognition rate may suffer from interferences from other readers. Since the reader interference can be mitigated by output signal power control, spectral and/or temporal separation among readers, the system performance depends on how to adapt the various reader arbitration metrics such as time, frequency, and output power to the system environment. However, complexity and difficulty of the optimization problem increase with respect to the variety of the arbitration metrics. Thus, most proposals in previous study have been suggested to primarily prevent the reader collision with consideration of one or two arbitration metrics. In this paper, we propose a novel cross-layer optimization design based on the concept of combining time division, frequency division, and power control not only to solve the reader interference problem, but also to achieve the multiple objectives such as minimum interrogation delay, maximum reader utilization, and energy efficiency. Based on the priority of the multiple objectives, our cross-layer design optimizes the system sequentially by means of the mixed-integer linear programming. In spite of the multi-stage optimization, the optimization design is formulated as a concise single mathematical form by properly assigning a weight to each objective. Numerical results demonstrate the effectiveness of the proposed optimization design.

  11. Texts and Readers.

    Science.gov (United States)

    Iser, Wolfgang

    1980-01-01

    Notes that, since fictional discourse need not reflect prevailing systems of meaning and norms or values, readers gain detachment from their own presuppositions; by constituting and formulating text-sense, readers are constituting and formulating their own cognition and becoming aware of the operations for doing so. (FL)

  12. Compact mobile-reader system for two-way wireless communication, tracking and status monitoring for transport safety and security

    Science.gov (United States)

    Tsai, Han-Chung; Liu, Yung Y.; Lee, Hok L.; Craig, Brian; Byrne, Kevin; Mittal, Ketan; Scherer, Justin C.

    2016-12-06

    A system for monitoring a plurality radio frequency identification tags is described. The system uses at least one set of radio frequency identification tags. Each tag is attached to a container and includes several sensors for detecting physical conditions of said container. The system includes at least one autonomous intermediate reader in wireless communication with the frequency identification tags. The intermediate reader includes external wireless communication system, intermediate reader logic controller, and a self-contained rechargeable power supply. The system uses a central status reporting system in communication the intermediate reader.

  13. Bipolar Plates for PEM Systems

    OpenAIRE

    Lædre, Sigrid

    2016-01-01

    Summary of thesis: The Bipolar Plate (BPP) is an important component in both Proton Exchange Membrane Fuel Cells (PEMFCs) and Proton Exchange Membrane Water Electrolyzers (PEMWEs). Bipolar plate material and processing constitutes for a large fraction of the cost and weight of a PEM cell stack. The main tasks for the bipolar plates in both systems are to separate single cell in a stack, conduct current between single cells and remove heat from active areas. In addition, the BPPs distribu...

  14. Root-Contact/Pressure-Plate Assembly For Hydroponic System

    Science.gov (United States)

    Morris, Carlton E.; Loretan, Philip A.; Bonsi, Conrad K.; Hill, Walter A.

    1994-01-01

    Hydroponic system includes growth channels equipped with rootcontact/pressure-plate assemblies. Pump and associated plumbing circulate nutrient liquid from reservoir, along bottom of growth channels, and back to reservoir. Root-contact/pressure-plate assembly in each growth channel stimulates growth of roots by applying mild contact pressure. Flat plate and plate connectors, together constitute pressure plate, free to move upward to accommodate growth of roots. System used for growing sweetpotatoes and possibly other tuber and root crops.

  15. A simple scoring system for breast MRI interpretation: does it compensate for reader experience?

    International Nuclear Information System (INIS)

    Marino, Maria Adele; Clauser, Paola; Woitek, Ramona; Wengert, Georg J.; Kapetas, Panagiotis; Bernathova, Maria; Pinker-Domenig, Katja; Helbich, Thomas H.; Baltzer, Pascal A.T.; Preidler, Klaus

    2016-01-01

    To investigate the impact of a scoring system (Tree) on inter-reader agreement and diagnostic performance in breast MRI reading. This IRB-approved, single-centre study included 100 patients with 121 consecutive histopathologically verified lesions (52 malignant, 68 benign). Four breast radiologists with different levels of MRI experience and blinded to histopathology retrospectively evaluated all examinations. Readers independently applied two methods to classify breast lesions: BI-RADS and Tree. BI-RADS provides a reporting lexicon that is empirically translated into likelihoods of malignancy; Tree is a scoring system that results in a diagnostic category. Readings were compared by ROC analysis and kappa statistics. Inter-reader agreement was substantial to almost perfect (kappa: 0.643-0.896) for Tree and moderate (kappa: 0.455-0.657) for BI-RADS. Diagnostic performance using Tree (AUC: 0.889-0.943) was similar to BI-RADS (AUC: 0.872-0.953). Less experienced radiologists achieved AUC: improvements up to 4.7 % using Tree (P-values: 0.042-0.698); an expert's performance did not change (P = 0.526). The least experienced reader improved in specificity using Tree (16 %, P = 0.001). No further sensitivity and specificity differences were found (P > 0.1). The Tree scoring system improves inter-reader agreement and achieves a diagnostic performance similar to that of BI-RADS. Less experienced radiologists, in particular, benefit from Tree. (orig.)

  16. A Real-time License Plate Detection System for Parking Access

    Directory of Open Access Journals (Sweden)

    Roenadi Koesdijarto

    2010-08-01

    Full Text Available The automatic and real-time license plate detection system can be used as an access control entry of vehicles into the parking area. The problem is how to recognize the vehicles that will go into the parking lot and how to recognize various types of license plates in various light conditions quickly and accurately. In this research, the prototype was developed with a detection system to recognize the vehicles that will enter the parking area, and a license plate recognition system. In the license plate recognition system, the Fourier transform and Hidden Markov model method have proposed to detect location of license plate and as characters segmentation to recognize Indonesia license plates. The research results have shown that the developed prototype system has successfully recognized all Indonesia license plates in several of light condition and camera position. The percentage of plate recognition in the real-time experiment is 84.38%, and the average execution time for all recognition process is 5.834 second.

  17. Experimental Study of an SWH System with V-Shaped Plate

    Directory of Open Access Journals (Sweden)

    Jalaluddin

    2016-05-01

    Full Text Available Solar energy is known as an environmentally friendly energy source with a wide range of applications. This energy can be utilized in various applications such as domestic and industrial water heating using solar water heating (SWH systems. The thermal performance of an SWH system using a V-shaped absorber plate is presented in this study. Two SWH systems with different absorber plates, i.e. a flat-plate and a V-shaped plate, have been investigated experimentally. First, the absorptivity of the absorber plates was calculated analytically. The optimum V-shaped configuration with angle at β = 21° (V-shaped dimensions t = 4 cm and l = 4 cm was determined from various V-shaped plate absorbers based on their absorptivity and applied in the experimental study. Two SWH systems were installed and tested at a low flowrate of 0.5 L/min and at a high flowrate of 2 L/min. The results showed that the SWH system with V-shaped plate absorber had a 3.6-4.4% better performance compared with that of the system with flat-plate absorber.

  18. Design And Implementation Of Bank Locker Security System Based On Fingerprint Sensing Circuit And RFID Reader

    Directory of Open Access Journals (Sweden)

    Khaing Mar Htwe

    2015-07-01

    Full Text Available Abstract The main goal of this system is to design a locker security system using RFID and Fingerprint. In this system only authenticated person can open the door. A security system is implemented containing door locking system using passive type of RFID which can activate authenticate and validate the user and unlock the door in real time for secure access. The advantage of using passive RFID is that it functions without a battery and passive tags are lighter and are less expensive than the active tags. This system consists of fingerprint reader microcontroller RFID reader and PC. The RFID reader reads the id number from passive. The fingerprint sensor will check incoming image with enrolled data and it will send confirming signal for C program. If both RFID check and fingerprint image confirmation are matched the microcontroller will drive door motor according to sensors at door edges. This system is more secure than other systems because two codes protection method used.

  19. Performance of the PBX-M passive plate stabilization system

    International Nuclear Information System (INIS)

    Kugel, H.W.; Bell, R.; Bernabei, S.

    1994-02-01

    The PBX-M passive plate stabilization system provides significant stabilization of long-wavelength external kink modes, the slowing of vertical instability growth rates, and the amelioration of disruption characteristics. The passive plate stabilization system has allowed the use of LHCD and IBW to induce current density and pressure profile modifications, and m = 1 divertor biasing for modifying edge plasma transport. Improvements in the passive plate system insulators and support structures have provided reliable operation. Impurity influxes with the close-fitting passive plates are low. Solid target boronization is applied routinely to reduce conditioning time and maintain clean conditions

  20. End plate marrow changes in the asymptomatic lumbosacral spine: frequency, distribution and correlation with age and degenerative changes

    International Nuclear Information System (INIS)

    Chung, Christine B.; Vande Berg, Bruno C.; Malghem, Jacques; Tavernier, Thierry; Cotten, Anne; Laredo, Jean-Denis; Vallee, Christian

    2004-01-01

    To investigate the frequency and distribution of end plate marrow signal intensity changes in an asymptomatic population and to correlate these findings with patient age and degenerative findings in the spine. MR imaging studies of the lumbosacral (LS) spine in 59 asymptomatic subjects were retrospectively reviewed by 2 musculoskeletal radiologists to determine the presence and location of fat-like and edema-like marrow signal changes about the end plates of the L1-2 through L5-S1 levels. The presence of degenerative changes in the spine was recorded as was patient age. Descriptive statistics were utilized to determine the frequency and associations of end plate findings and degenerative changes in the spine. Interobserver variability was determined by a kappa score. Binomial probability was used to predict the prevalence of the end plate changes in a similar subject population. The Fisher exact test was performed to determine statistical significance of the relationship of end plate changes with degenerative changes in the spine, superior versus inferior location about the disc and age of the patient population. Focal fat-like signal intensity adjacent to the vertebral end-plate was noted in 15 out of 59 subjects by both readers, and involved 38 and 36 out of 590 end plates by readers 1 and 2, respectively. Focal edema-like signal intensity adjacent to the vertebral end plate was noted in 8 out of 59 subjects by both readers and involved 11 and 10 out of 590 end plates by readers 1 and 2, respectively. Either fat or edema signal intensity occurred most often at the anterior (p<.05) aspects of the mid-lumbar spine and was seen in an older sub-population of the study (p<.05). End plate marrow signal intensity changes are present in the lumbar spine of some asymptomatic subjects with a characteristic location along the spine and in vertebral end plates. (orig.)

  1. Inert gas handling in ion plating systems

    International Nuclear Information System (INIS)

    Goode, A.R.; Burden, M.St.J.

    1979-01-01

    The results of an investigation into the best methods for production and monitoring of the inert gas environment for ion plating systems are reported. Work carried out on Pirani gauges and high pressure ion gauges for the measurement of pressures in the ion plating region (1 - 50mtorr) and the use of furnaces for cleaning argon is outlined. A schematic of a gas handling system is shown and discussed. (UK)

  2. Automatic Number Plate Recognition System for IPhone Devices

    Directory of Open Access Journals (Sweden)

    Călin Enăchescu

    2013-06-01

    Full Text Available This paper presents a system for automatic number plate recognition, implemented for devices running the iOS operating system. The methods used for number plate recognition are based on existing methods, but optimized for devices with low hardware resources. To solve the task of automatic number plate recognition we have divided it into the following subtasks: image acquisition, localization of the number plate position on the image and character detection. The first subtask is performed by the camera of an iPhone, the second one is done using image pre-processing methods and template matching. For the character recognition we are using a feed-forward artificial neural network. Each of these methods is presented along with its results.

  3. Implementation of an FPGA based system survey and diagnostic reader with the aim to increase system dependability

    CERN Document Server

    Alsdorf, M; Kwiatkowski, M; Vigano, W; Zamantzas, C

    2012-01-01

    The operation and machine protection of accelerators practically rely on their underlying instrumentation systems and a failure of any of those systems could pose a significant impact on the overall reliability and availability. In order to improve the detection and in some cases the prevention of failures, a survey mechanism could be integrated to the system that collects crucial information about the current system status through a number of acquisition modules. The implementation and integration of such a method is presented with the aim to standardize the implementation, where the acquisition modules share a common build and are connected through a standardized interface to a survey reader. The reader collects regularly data and controls the readout intervals. The information collected from these modules is used locally in the FPGA device to identify critical system failures and results in an immediate failsafe reaction with the data also transmitted and stored in external databases for offline analysis.

  4. A Malaysian Vehicle License Plate Localization and Recognition System

    Directory of Open Access Journals (Sweden)

    Ganapathy Velappa

    2008-02-01

    Full Text Available Technological intelligence is a highly sought after commodity even in traffic-based systems. These intelligent systems do not only help in traffic monitoring but also in commuter safety, law enforcement and commercial applications. In this paper, a license plate localization and recognition system for vehicles in Malaysia is proposed. This system is developed based on digital images and can be easily applied to commercial car park systems for the use of documenting access of parking services, secure usage of parking houses and also to prevent car theft issues. The proposed license plate localization algorithm is based on a combination of morphological processes with a modified Hough Transform approach and the recognition of the license plates is achieved by the implementation of the feed-forward backpropagation artificial neural network. Experimental results show an average of 95% successful license plate localization and recognition in a total of 589 images captured from a complex outdoor environment.

  5. Automatic system for localization and recognition of vehicle plate numbers

    OpenAIRE

    Vázquez, N.; Nakano, M.; Pérez-Meana, H.

    2003-01-01

    This paper proposes a vehicle numbers plate identification system, which extracts the characters features of a plate from a captured image by a digital camera. Then identify the symbols of the number plate using a multilayer neural network. The proposed recognition system consists of two processes: The training process and the recognition process. During the training process, a database is created using 310 vehicular plate images. Then using this database a multilayer neural network is traine...

  6. MRI interrReader and intra-reader reliabilities for assessing injury morphology and posterior ligamentous complex integrity of the spine according to the thoracolumbar injury classification system and severity score

    International Nuclear Information System (INIS)

    Lee, Guen Young; Lee, Joon Woo; Choi, Seung Woo; Lim, Hyun Jin; Sun, Hye Young; Kang, Yu Suhn; Kang, Heung Sik; Chai, Jee Won; Kim, Su Jin

    2015-01-01

    To evaluate spine magnetic resonance imaging (MRI) inter-reader and intra-reader reliabilities using the thoracolumbar injury classification system and severity score (TLICS) and to analyze the effects of reader experience on reliability and the possible reasons for discordant interpretations. Six radiologists (two senior, two junior radiologists, and two residents) independently scored 100 MRI examinations of thoracolumbar spine injuries to assess injury morphology and posterior ligamentous complex (PLC) integrity according to the TLICS. Inter-reader and intra-reader agreements were determined and analyzed according to the number of years of radiologist experience. Inter-reader agreement between the six readers was moderate (k = 0.538 for the first and 0.537 for the second review) for injury morphology and fair to moderate (k = 0.440 for the first and 0.389 for the second review) for PLC integrity. No significant difference in inter-reader agreement was observed according to the number of years of radiologist experience. Intra-reader agreements showed a wide range (k = 0.538-0.822 for injury morphology and 0.423-0.616 for PLC integrity). Agreement was achieved in 44 for the first and 45 for the second review about injury morphology, as well as in 41 for the first and 38 for the second review of PLC integrity. A positive correlation was detected between injury morphology score and PLC integrity. The reliability of MRI for assessing thoracolumbar spinal injuries according to the TLICS was moderate for injury morphology and fair to moderate for PLC integrity, which may not be influenced by radiologist' experience

  7. An Design of HF-Band RFID System with Multiple Readers and Passive Tags for Indoor Mobile Robot Self-Localization

    Directory of Open Access Journals (Sweden)

    Jian Mi

    2016-07-01

    Full Text Available Radio frequency identification (RFID technology has already been explored for efficient self-localization of indoor mobile robots. A mobile robot equipped with RFID readers detects passive RFID tags installed on the floor in order to locate itself. The Monte-Carlo localization (MCL method enables the localization of a mobile robot equipped with an RFID system with reasonable accuracy, sufficient robustness and low computational cost. The arrangements of RFID readers and tags and the size of antennas are important design parameters for realizing accurate and robust self-localization using a low-cost RFID system. The design of a likelihood model of RFID tag detection is also crucial for the accurate self-localization. This paper presents a novel design and arrangement of RFID readers and tags for indoor mobile robot self-localization. First, by considering small-sized and large-sized antennas of an RFID reader, we show how the design of the likelihood model affects the accuracy of self-localization. We also design a novel likelihood model by taking into consideration the characteristics of the communication range of an RFID system with a large antenna. Second, we propose a novel arrangement of RFID tags with eight RFID readers, which results in the RFID system configuration requiring much fewer readers and tags while retaining reasonable accuracy of self-localization. We verify the performances of MCL-based self-localization realized using the high-frequency (HF-band RFID system with eight RFID readers and a lower density of RFID tags installed on the floor based on MCL in simulated and real environments. The results of simulations and real environment experiments demonstrate that our proposed low-cost HF-band RFID system realizes accurate and robust self-localization of an indoor mobile robot.

  8. Development of a new microtiter plate format for clinically relevant assays.

    Science.gov (United States)

    Piletska, Elena V; Piletsky, Stanislav S; Whitcombe, Michael J; Chianella, Iva; Piletsky, Sergey A

    2012-02-21

    A new format for the microtiter plate-based assays was proposed. The novelty involves the use of disk-shaped inserts for immobilization of biological and chemical reagents. The internal opening of the disks allows measurements of the reactions by standard microtiter plate readers without any additional steps involving liquid handling. Ideally the plate end-users just have to add the sample and take the measurement without any need of multiple reagent additions or transfer of the liquid to a different plate. The novel assay format also allows handling of reagents which are not soluble in an aqueous environment. As a proof of concept we describe here several model reactions which are compatible with microtiter plate format, such as monitoring enzymatic reactions catalyzed by glucose oxidase (GOx) and urease, measurements of proteins by BCA assay, analysis of pH, and concentration of antioxidants. The "mix and match" approach in the disk-shape format allows multiplexing and could be particularly useful for high throughput screening. One of the potential application areas for this novel assay format could be in a multianalyte system for measurement of clinically relevant analytes in primary care.

  9. N2 gas station and gas distribution system for TLD personnel monitoring gas based semi-automatic badge readers

    International Nuclear Information System (INIS)

    Chourasiya, G.; Pradhan, S.M.; Kher, R.K.; Bhatt, B.C

    2003-01-01

    Full text: New improvised hot gas based Auto TLD badge reader has several advantages over the earlier contact heating based manual badge reader. It requires constant supply of N 2 gas for its operation; The gas supplied using replaceable individual gas cylinders may have some safety hazards in their handling. It was therefore considered worthwhile to setup a N 2 gas assembly/ station outside the lab area and to bring regulated gas supply through network of tubes with proper regulation to the individual readers. The paper presents detailed description of the gas station and distribution system. The system is quite useful and offers several practical advantages for readout of TLD badges on the semiautomatic badge readers based on gas heating. Important advantage from dosimetric point of view is avoidance of gas flow rate fluctuations and corresponding variations in TL readouts

  10. Composite Bipolar Plate for Unitized Fuel Cell/Electrolyzer Systems

    Science.gov (United States)

    Mittelsteadt, Cortney K.; Braff, William

    2009-01-01

    In a substantial improvement over present alkaline systems, an advanced hybrid bipolar plate for a unitized fuel cell/electrolyzer has been developed. This design, which operates on pure feed streams (H2/O2 and water, respectively) consists of a porous metallic foil filled with a polymer that has very high water transport properties. Combined with a second metallic plate, the pore-filled metallic plates form a bipolar plate with an empty cavity in the center.

  11. A bar-code reader for an alpha-beta automatic counting system - FAG

    Energy Technology Data Exchange (ETDEWEB)

    Levinson, S; Shemesh, Y; Ankry, N; Assido, H; German, U; Peled, O [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    A bar-code laser system for sample number reading was integrated into the FAG Alpha-Beta automatic counting system. The sample identification by means of an attached bar-code label enables unmistakable and reliable attribution of results to the counted sample. Installation of the bar-code reader system required several modifications: Mechanical changes in the automatic sample changer, design and production of new sample holders, modification of the sample planchettes, changes in the electronic system, update of the operating software of the system (authors).

  12. A bar-code reader for an alpha-beta automatic counting system - FAG

    International Nuclear Information System (INIS)

    Levinson, S.; Shemesh, Y.; Ankry, N.; Assido, H.; German, U.; Peled, O.

    1996-01-01

    A bar-code laser system for sample number reading was integrated into the FAG Alpha-Beta automatic counting system. The sample identification by means of an attached bar-code label enables unmistakable and reliable attribution of results to the counted sample. Installation of the bar-code reader system required several modifications: Mechanical changes in the automatic sample changer, design and production of new sample holders, modification of the sample planchettes, changes in the electronic system, update of the operating software of the system (authors)

  13. Plate Tectonics as a Far-From-Equilibrium Self-Organized Dissipative System

    Science.gov (United States)

    Anderson, D. L.

    2001-12-01

    A fluid above the critical Rayleigh number is far from equilibrium and spontaneously organizes itself into patterns involving the collective motion of large numbers of molecules which are resisted by the viscosity of the fluid. No external template is involved in forming the pattern. In 1928 Pearson showed that Bénard's experiments were driven by variations in surface tension at the top of the fluid and the surface motions drove convection in the fluid. In this case, the surface organized itself AND the underlying fluid. Both internal buoyancy driven flow and flow driven by surface forces can be far-from-equilibrium self-organized open systems that receive energy and matter from the environment. In the Earth, the cold thermal boundary layer at the surface drives plate tectonics and introduces temperature, shear and pressure gradients into the mantle that drive mantle convection. The mantle provides energy and material but may not provide the template. Plate tectonics is therefore a candidate for a far-from-equilibrium dissipative self-organizing system. Alternatively, one could view mantle convection as the self-organized system and the plates as simply the surface manifestation. Lithospheric architecture also imposes lateral temperature gradients onto the mantle which can drive and organize flow. Far-from-equilibrium self-organization requires; an open system, interacting parts, nonlinearities or feedbacks, an outside steady source of energy or matter, multiple possible states and a source of dissipation. In uniform fluids viscosity is the source of dissipation. Sources of dissipation in the plate system include bending, breaking, folding, shearing, tearing, collision and basal drag. These can change rapidly, in contrast to plate driving forces, and introduce the sort of fluctuations that can reorganize far-from-equilibrium systems. Global plate reorganizations can alternatively be thought of as convective overturns of the mantle, or thermal weakening of plates

  14. A new fully automated TLD badge reader

    International Nuclear Information System (INIS)

    Kannan, S.; Ratna, P.; Kulkarni, M.S.

    2003-01-01

    At present personnel monitoring in India is being carried out using a number of manual and semiautomatic TLD badge Readers and the BARC TL dosimeter badge designed during 1970. Of late the manual TLD badge readers are almost completely replaced by semiautomatic readers with a number of performance improvements like use of hot gas heating to reduce the readout time considerably. PC based design with storage of glow curve for every dosimeter, on-line dose computation and printout of dose reports, etc. However the semiautomatic system suffers from the lack of a machine readable ID code on the badge and the physical design of the dosimeter card not readily compatible for automation. This paper describes a fully automated TLD badge Reader developed in the RSS Division, using a new TLD badge with machine readable ID code. The new PC based reader has a built-in reader for reading the ID code, in the form of an array of holes, on the dosimeter card. The reader has a number of self-diagnostic features to ensure a high degree of reliability. (author)

  15. Laboratory evaluation of 3M Petrifilms and University of Minnesota Bi-plates as potential on-farm tests for clinical mastitis.

    Science.gov (United States)

    McCarron, J L; Keefe, G P; McKenna, S L B; Dohoo, I R; Poole, D E

    2009-05-01

    The objective was to determine test characteristics and compare 2 potential on-farm culture systems for clinical mastitis, the Minnesota Easy Culture System II Bi-plate and Petrifilm. The tests were evaluated using clinically positive mastitic milk samples (n = 282) to determine their ability to differentiate appropriate treatment groups; all cases that had gram-positive growth were considered treatment candidates (n = 161), whereas cases that grew gram-negative organisms only or yielded no bacterial growth were classified as no treatment (n = 121). For Petrifilm, both undiluted and 1:10 diluted milk samples were used. To create treatment categories, 2 types of Petrifilms were used, Aerobic Count (AC) and Coliform Count (CC). Both Bi-plates and Petrifilms were read after 24 h of incubation. Analysis was conducted at various colony count thresholds for the Petrifilm test system. The combination of Petrifilms that had the highest sensitivity classified a case as gram-negative if there were > or =20 colonies present on the CC. If there were 5 colonies present on the AC, a case would be classified as gram-positive. The Bi-plate had a sensitivity of 97.9% and a specificity of 68.6%. The Petrifilm test system had a sensitivity of 93.8% and a specificity of 70.1%. There was no significant difference in the sensitivities between the tests. All Bi-plates and Petrifilms were read by a laboratory technician and a group of masked readers with limited microbiology training. Kappa values for the masked readers were 0.75 for Bi-plates and 0.84 and 0.86 for AC and CC Petrifilms, respectively. The Bi-plate and Petrifilm were able to successfully categorize clinical cases of mastitis into 2 treatments based on their ability to detect the presence of a gram-positive organism. Neither method had the ability to determine if a sample was contaminated. The results of this study indicate that both tests were able to appropriately categorize cases, which could potentially result in a

  16. What Can Readers Read after Graded Readers?

    Science.gov (United States)

    McQuillan, Jeff

    2016-01-01

    Nation (2014) concluded that most of the vocabulary one needs to read challenging texts in English can be acquired incidentally through voluminous reading. This study examines possible texts that second language (L2) readers can use to move from controlled-vocabulary materials such as graded readers, which go up through approximately the…

  17. A radiophotoluminescent glass plate system for medium-sized field dosimetry

    International Nuclear Information System (INIS)

    Nakagawa, Keiichi; Koyanagi, Hiroki; Shiraki, Takashi; Saegusa, Shigeki; Sasaki, Katsutake; Oritate, Takashi; Mima, Kazuo; Miyazawa, Masanori; Ishidoya, Tatsuyo; Ohtomo, Kuni; Yoda, Kiyoshi

    2005-01-01

    A two-dimensional radiophotoluminescent system for medium-sized field dosimetry has been developed using a silver-activated phosphate glass plate with a dimension of 120 mmx120 mmx1 mm and a readout unit comprising a UV excitation lamp and a CCD imager. A dose ranging from 0 to 400 cGy, provided by a 6 MV x-ray beam, was delivered to the glass plate oriented perpendicularly to the beam and positioned in a water phantom at a depth of 10 cm, where the center of the glass plate coincided with the linac isocenter. After the dose delivery, the glass plate was placed in the readout system. The CCD output intensity increased linearly with the applied dose. The angular dependence of response on the direction of radiation incidence was measured by rotating the glass plate in the water phantom, indicating that the output remained constant up to 75 deg. from perpendicular incident direction, followed by a steep reduction down to 85% at an angle of 90 deg. A lateral dose distribution resulting from a 60 mmx60 mm irradiation was compared between the glass plate and an x-ray film having had the same exposure, showing that the glass plate and the x-ray film led to identical dose distributions. The dose reproducibility for a glass plate and the sensitivity variation among different glass plates were also evaluated

  18. CAC on a MAC: setting up a DOD Common Access Card reader on the Macintosh OS X operating system

    OpenAIRE

    Hopfner, Phil

    2006-01-01

    The Naval Postgraduate School, along with many other Department of Defense (DOD) organizations, utilizes the ActivCard USB Common Access Card (CAC) readers. The CAC readers in conjunction with the user's Smart Card enables access to DOD PKI-enabled websites and allows the user to send signed and encrypted email utilizing the DOD Public Key Infrastructure (PKI). Microsoft Windows systems utilize the ActivCard Gold middleware software to enable CAC reader functionality. This software packag...

  19. Virtual haptic system for intuitive planning of bone fixation plate placement

    Directory of Open Access Journals (Sweden)

    Kup-Sze Choi

    2017-01-01

    Full Text Available Placement of pre-contoured fixation plate is a common treatment for bone fracture. Fitting of fixation plates on fractured bone can be preoperatively planned and evaluated in 3D virtual environment using virtual reality technology. However, conventional systems usually employ 2D mouse and virtual trackball as the user interface, which makes the process inconvenient and inefficient. In the paper, a preoperative planning system equipped with 3D haptic user interface is proposed to allow users to manipulate the virtual fixation plate intuitively to determine the optimal position for placement on distal medial tibia. The system provides interactive feedback forces and visual guidance based on the geometric requirements. Creation of 3D models from medical imaging data, collision detection, dynamics simulation and haptic rendering are discussed. The system was evaluated by 22 subjects. Results show that the time to achieve optimal placement using the proposed system was shorter than that by using 2D mouse and virtual trackball, and the satisfaction rating was also higher. The system shows potential to facilitate the process of fitting fixation plates on fractured bones as well as interactive fixation plate design.

  20. Non-destructive evaluation utilizing imaging plates for field radiography applications

    International Nuclear Information System (INIS)

    White, Brian S.

    2016-01-01

    The oil and gas industry has utilized film radiography for the evaluation of pipeline welds for many years. The world has evolved, and today people are easily sharing digital images as part of the information revolution. Computed radiography is ready to replace film radiography for portable outdoor use applications. Computed radiography technology adoption has been contingent upon achieving acceptable image quality and getting enough imaging plate use cycles to be profitable. Image quality is dependent upon shot conditions, imaging plate type, reader settings, and scatter control. Likewise, the number of achievable use cycles is dependent upon the imaging plate design for durability and the user's operating environment. This presentation reviews the basic principles of storage phosphor imaging plates. Usage criteria and guidelines for optimum image quality and maximized overall use cycles will be discussed for various imaging plate types. A comparison of film and computed radiography imaging plate technology will be presented.

  1. Overview of PADC nuclear track readers. Recent trends and solutions

    International Nuclear Information System (INIS)

    Hulber, E.

    2009-01-01

    The development of automated track readers dates back to the first routine dosimetry applications of solid state nuclear track detectors. Many research-laboratory track readers and a few commercial systems were introduced in the past 25 years. The traditional application area for high-throughput track readers is radon testing in buildings and fast neutron dosimetry. The latter application, in particular, has considerably increased the need for efficient polyallyldiglycol carbonate (PADC) track reader systems with high throughput. The paper provides an overview of recent trends in the development of high-throughput PADC track readers and it gives a glimpse into the practice of designing this category of devices. A general overview is provided of the technical aspects relating to the optics, the hardware and the track recognition approaches. Ultimate theoretical limits in the performance as well as promising new approaches are addressed. Requirements and practical solutions are illustrated with reference to a commercially available system.

  2. Improving greater trochanteric reattachment with a novel cable plate system.

    Science.gov (United States)

    Baril, Yannick; Bourgeois, Yan; Brailovski, Vladimir; Duke, Kajsa; Laflamme, G Yves; Petit, Yvan

    2013-03-01

    Cable-grip systems are commonly used for greater trochanteric reattachment because they have provided the best fixation performance to date, even though they have a rather high complication rate. A novel reattachment system is proposed with the aim of improving fixation stability. It consists of a Y-shaped fixation plate combined with locking screws and superelastic cables to reduce cable loosening and limit greater trochanter movement. The novel system is compared with a commercially available reattachment system in terms of greater trochanter movement and cable tensions under different greater trochanteric abductor application angles. A factorial design of experiments was used including four independent variables: plate system, cable type, abductor application angle, and femur model. The test procedure included 50 cycles of simultaneous application of an abductor force on the greater trochanter and a hip force on the femoral head. The novel plate reduces the movements of a greater trochanter fragment within a single loading cycle up to 26%. Permanent degradation of the fixation (accumulated movement based on 50-cycle testing) is reduced up to 46%. The use of superelastic cables reduces tension loosening up to 24%. However this last improvement did not result in a significant reduction of the grater trochanter movement. The novel plate and cables present advantages over the commercially available greater trochanter reattachment system. The plate reduces movements generated by the hip abductor. The superelastic cables reduce cable loosening during cycling. Both of these positive effects could decrease the risks related to grater trochanter non-union. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  3. Stress and displacement analysis of a core plate, i.e. grid-perforated plate compound, modelled as an equivalent beam system

    International Nuclear Information System (INIS)

    Frank, R.; Engel, R.

    1979-01-01

    The core support plate is a very important component of the reactor pressure vessel internals. Therefore, an exact stress analysis is desired. This analysis will cause high computer costs with a detailed FEM-model because of the complexity of this compound system. In this paper, a method is suggested to solve the problem with a much cheaper beam element model. The main problem is to establish an equivalent beam system with nearly the same stiffness property as the perforated circular plate stiffened by a grid. Furthermore, the system must allow to determine the maximum stresses with sufficient accuracy. The calculation of the equivalent beam stiffness is based on the analysis of perforated plates by T. SLOT and W.J. O'DONNELL. This analysis method utilizes the concept of the equivalent solid plate. In this method, the perforated plate is replaced by a solid one which is geometrically similar to the perforated plate but has modified values of the elastic constants. The simple equivalent beam system of one half of the core support plate (symmetry) was loaded with a pressure difference and stresses and displacements were analysed. After that, these results were compared with the stress and displacement analysis of a part of the real structure. This substructure was discretized by three-dimensional 20-node brick-elements. The comparison of the results of the two models shows that the stresses and displacements, calculated with the simple beam model, are in good agreement with those of the real structure. (orig.)

  4. Comparative evaluation of 2.3 mm locking plate system vs conventional 2.0 mm non locking plate system for mandibular condyle fracture fixation: a seven year retrospective study.

    Science.gov (United States)

    Zhang, J; Wang, X; Wu, R-H; Zhuang, Q-W; Gu, Q P; Meng, J

    2015-01-01

    This retrospective study evaluated the efficacy of a 2.3 mm locking plate/screw system compared with a 2.0-mm non-locking plate/screw system in fixation of isolated non comminuted mandibular condyle fractures. Surgical records of 101 patients who received either a 2.3 mm locking plate (group A, n = 51) or 2.0 mm non locking plate (group B, n = 50) were analyzed. All patients were followed up to a minimum of 6 months postoperatively and evaluated for hardware related complications, occlusal stability, need for and duration of MMF and mandibular functional results. Four complications occurred in the locking group and eighteen in the non locking group with complication rates equalling 8% and 36% respectively. When comparing the overall results according to plates used, the χ2 test showed a statistically significant difference between the locking and non locking plates (p Mandibular condyle fractures treated with a 2.3 mm locking plate exhibited stable osteosynthesis, were associated with minimal complications and resulted in acceptable mandibular range of motion compared with a 2.0 mm non locking plate.

  5. Extending the E-Z Reader Model of Eye Movement Control to Chinese Readers

    Science.gov (United States)

    Rayner, Keith; Li, Xingshan; Pollatsek, Alexander

    2007-01-01

    Chinese readers' eye movements were simulated in the context of the E-Z Reader model, which was developed to account for the eye movements of readers of English. Despite obvious differences between English and Chinese, the model did a fairly good job of simulating the eye movements of Chinese readers. The successful simulation suggests that the…

  6. Thermoluminescence dosimeter reader

    International Nuclear Information System (INIS)

    Robertson, M.E.A.; Marshall, J.; Brabants, J.A.P.; Davies, M.E.

    1975-01-01

    An electric circuit arrangement is described including a photomultiplier tube and a high voltage source therefor also includes a feedback loop from the output of the tube to the high voltage source, and loop providing automatic gain stabilization for the tube. The arrangement is used in a dosimeter reader to provide sensitivity correction for the reader each time the reader is to be used

  7. Global Plate Velocities from the Global Positioning System

    Science.gov (United States)

    Larson, Kristine M.; Freymueller, Jeffrey T.; Philipsen, Steven

    1997-01-01

    We have analyzed 204 days of Global Positioning System (GPS) data from the global GPS network spanning January 1991 through March 1996. On the basis of these GPS coordinate solutions, we have estimated velocities for 38 sites, mostly located on the interiors of the Africa, Antarctica, Australia, Eurasia, Nazca, North America, Pacific, and South America plates. The uncertainties of the horizontal velocity components range from 1.2 to 5.0 mm/yr. With the exception of sites on the Pacific and Nazca plates, the GPS velocities agree with absolute plate model predictions within 95% confidence. For most of the sites in North America, Antarctica, and Eurasia, the agreement is better than 2 mm/yr. We find no persuasive evidence for significant vertical motions (less than 3 standard deviations), except at four sites. Three of these four were sites constrained to geodetic reference frame velocities. The GPS velocities were then used to estimate angular velocities for eight tectonic plates. Absolute angular velocities derived from the GPS data agree with the no net rotation (NNR) NUVEL-1A model within 95% confidence except for the Pacific plate. Our pole of rotation for the Pacific plate lies 11.5 deg west of the NNR NUVEL-1A pole, with an angular speed 10% faster. Our relative angular velocities agree with NUVEL-1A except for some involving the Pacific plate. While our Pacific-North America angular velocity differs significantly from NUVEL-1A, our model and NUVEL-1A predict very small differences in relative motion along the Pacific-North America plate boundary itself. Our Pacific-Australia and Pacific- Eurasia angular velocities are significantly faster than NUVEL-1A, predicting more rapid convergence at these two plate boundaries. Along the East Pacific Pise, our Pacific-Nazca angular velocity agrees in both rate and azimuth with NUVFL-1A.

  8. An Edge-Based Macao License Plate Recognition System

    Directory of Open Access Journals (Sweden)

    Chi-Man Pun

    2011-04-01

    Full Text Available This paper presents a system to recognize Macao license plates. Sobel edge detector is employed to extract the vertical edges, and an edge composition algorithm is proposed to combine the edges into candidate plate regions. They are further examined on the existence of the character qMq by a verification algorithm. A row separation algorithm is also proposed to cater both one-row and two-row types of plates. Projection analysis and template matching methods are exploited to segment and recognize the characters. Various pre and post processing steps are proposed other than traditional implementation so as to improve the recognition accuracy. This work achieves a high recognition rate of 95%.

  9. Biomechanical properties of orthogonal plate configuration versus parallel plate configuration using the same locking plate system for intra-articular distal humeral fractures under radial or ulnar column axial load.

    Science.gov (United States)

    Kudo, Toshiya; Hara, Akira; Iwase, Hideaki; Ichihara, Satoshi; Nagao, Masashi; Maruyama, Yuichiro; Kaneko, Kazuo

    2016-10-01

    Previous reports have questioned whether an orthogonal or parallel configuration is superior for distal humeral articular fractures. In previous clinical and biomechanical studies, implant failure of the posterolateral plate has been reported with orthogonal configurations; however, the reason for screw loosening in the posterolateral plate is unclear. The purpose of this study was to evaluate biomechanical properties and to clarify the causes of posterolateral plate loosening using a humeral fracture model under axial compression on the radial or ulnar column separately. And we changed only the plate set up: parallel or orthogonal. We used artificial bone to create an Association for the Study of Internal Fixation type 13-C2.3 intra-articular fracture model with a 1-cm supracondylar gap. We used an anatomically-preshaped distal humerus locking compression plate system (Synthes GmbH, Solothurn, Switzerland). Although this is originally an orthogonal plate system, we designed a mediolateral parallel configuration to use the contralateral medial plate instead of the posterolateral plate in the system. We calculated the stiffness of the radial and ulnar columns and anterior movement of the condylar fragment in the lateral view. The parallel configuration was superior to the orthogonal configuration regarding the stiffness of the radial column axial compression. There were significant differences between the two configurations regarding anterior movement of the capitellum during axial loading of the radial column. The posterolateral plate tended to bend anteriorly under axial compression compared with the medial or lateral plate. We believe that in the orthogonal configuration axial compression induced more anterior displacement of the capitellum than the trochlea, which eventually induced secondary fragment or screw dislocation on the posterolateral plate, or nonunion at the supracondylar level. In the parallel configuration, anterior movement of the capitellum or

  10. [Development of polyaxial locking plate screw system of sacroiliac joint].

    Science.gov (United States)

    Fan, Weijie; Xie, Xuesong; Zhou, Shuping; Zhang, Yonghu

    2014-09-01

    To develop an instrument for sacroiliac joint fixation with less injury and less complications. Firstly, 18 adult pelvic specimens (8 males and 10 females) were used to measure the anatomical data related to the locking plates and locking screws on the sacrum and ilium, and the polyaxial locking plate screw system of the sacroiliac joint was designed according to the anatomic data. This system was made of medical titanium alloy. Then 4 adult male plevic specimens were harvested and the experiment was divided into 3 groups: group A (normal pelvic), group B (the dislocated sacroiliac joint fixed with sacroiliac screws), and group C (the dislocated sacroiliac joint fixed with polyaxial locking plate screw system). The vertical displacement of sacroiliac joint under the condition of 0-700 N vertical load and the horizontal displacement on angle under the condition of 0-12 N·m torsional load were compared among the 3 groups by using the biological material test system. Finally, the simulated application test was performed on 1 adult male cadaveric specimen to observe soft tissue injury and the position of the locking plate and screw by X-ray films. According to the anatomic data of the sacrum and ilium, the polyaxial locking plate screw system of the sacroiliac joint was designed. The biomechanical results showed that the vertical displacement of the sacroiliac joint under the condition of 0-700 N vertical load in group A was significantly bigger than that in group B and group C (P 0.05). The horizontal displacement on angle under the condition of 0-12 N·m torsional load in group A was significantly less than that in group B and group C (P 0.05). The test of simulating application showed that the specimen suffered less soft tissue injury, and this instrument could be implanted precisely and safely. The polyaxial locking plate screw system of the sacroiliac joint has the advantages of smaller volume and less injury; polyaxial fixation enables flexible adjustment screw

  11. Communications device identification methods, communications methods, wireless communications readers, wireless communications systems, and articles of manufacture

    Science.gov (United States)

    Steele, Kerry D [Kennewick, WA; Anderson, Gordon A [Benton City, WA; Gilbert, Ronald W [Morgan Hill, CA

    2011-02-01

    Communications device identification methods, communications methods, wireless communications readers, wireless communications systems, and articles of manufacture are described. In one aspect, a communications device identification method includes providing identification information regarding a group of wireless identification devices within a wireless communications range of a reader, using the provided identification information, selecting one of a plurality of different search procedures for identifying unidentified ones of the wireless identification devices within the wireless communications range, and identifying at least some of the unidentified ones of the wireless identification devices using the selected one of the search procedures.

  12. Lighting system for the lower core plate of a nuclear reactor

    International Nuclear Information System (INIS)

    Feuillet, P.; Bonin, J.P.

    1986-01-01

    The invention proposes a grazing lighting system for the lower core plate, creating an excellent contrast and offering a good estimation of the relief; it can stay at the same place during the whole or at least the greater part of the core refueling operation. This lighting system is proposed for a reactor of which the lower core plate has fuel assembly centering elements. It has a sealed vessel with a transparent side wall containing several lights independently controlled and each one illuminating a sector of its wall. The vessel has a bottom aimed at resting on the lower plate and provided with centering and holding means acting with several of the said centering means through the plate, and/or apertures for coolant through the plate, and an upper container provided with gripping and handling elements and sealed conduits for electrical cables feeding the lights [fr

  13. An IoT Reader for Wireless Passive Electromagnetic Sensors.

    Science.gov (United States)

    Galindo-Romera, Gabriel; Carnerero-Cano, Javier; Martínez-Martínez, José Juan; Herraiz-Martínez, Francisco Javier

    2017-03-28

    In the last years, many passive electromagnetic sensors have been reported. Some of these sensors are used for measuring harmful substances. Moreover, the response of these sensors is usually obtained with laboratory equipment. This approach highly increases the total cost and complexity of the sensing system. In this work, a novel low-cost and portable Internet-of-Things (IoT) reader for passive wireless electromagnetic sensors is proposed. The reader is used to interrogate the sensors within a short-range wireless link avoiding the direct contact with the substances under test. The IoT functionalities of the reader allows remote sensing from computers and handheld devices. For that purpose, the proposed design is based on four functional layers: the radiating layer, the RF interface, the IoT mini-computer and the power unit. In this paper a demonstrator of the proposed reader is designed and manufactured. The demonstrator shows, through the remote measurement of different substances, that the proposed system can estimate the dielectric permittivity. It has been demonstrated that a linear approximation with a small error can be extracted from the reader measurements. It is remarkable that the proposed reader can be used with other type of electromagnetic sensors, which transduce the magnitude variations in the frequency domain.

  14. EDMC: An enhanced distributed multi-channel anti-collision algorithm for RFID reader system

    Science.gov (United States)

    Zhang, YuJing; Cui, Yinghua

    2017-05-01

    In this paper, we proposes an enhanced distributed multi-channel reader anti-collision algorithm for RFID environments which is based on the distributed multi-channel reader anti-collision algorithm for RFID environments (called DiMCA). We proposes a monitor method to decide whether reader receive the latest control news after it selected the data channel. The simulation result shows that it improves interrogation delay.

  15. DEAFNESS, RETELLING AND READER FOMATION

    Directory of Open Access Journals (Sweden)

    José Marcos Rosendo de Souza

    2016-07-01

    Full Text Available Research on formation of readers has raised some discussions and change of atitudes, to the development of full readers. But, the methodologies that strive for proficiency of Deaf readers there are scarse. We intend to discuss in this article the formation of a reader Deaf through from an interventional research, with cognitive approach. The reader formation of Deaf will be possible with appropriate method to their peculiarities.

  16. Cellphone-based hand-held microplate reader for point-of-care ELISA testing (Conference Presentation)

    Science.gov (United States)

    Berg, Brandon; Cortazar, Bingen; Tseng, Derek; Ozkan, Haydar; Feng, Steve; Wei, Qingshan; Chan, Raymond Y.; Burbano, Jordi; Farooqui, Qamar; Lewinski, Michael; Di Carlo, Dino; Garner, Omai B.; Ozcan, Aydogan

    2016-03-01

    Enzyme-linked immunosorbent assay (ELISA) in a microplate format has been a gold standard first-line clinical test for diagnosis of various diseases including infectious diseases. However, this technology requires a relatively large and expensive multi-well scanning spectrophotometer to read and quantify the signal from each well, hindering its implementation in resource-limited-settings. Here, we demonstrate a cost-effective and handheld smartphone-based colorimetric microplate reader for rapid digitization and quantification of immunoserology-related ELISA tests in a conventional 96-well plate format at the point of care (POC). This device consists of a bundle of 96 optical fibers to collect the transmitted light from each well of the microplate and direct all the transmission signals from the wells onto the camera of the mobile-phone. Captured images are then transmitted to a remote server through a custom-designed app, and both quantitative and qualitative diagnostic results are returned back to the user within ~1 minute per 96-well plate by using a machine learning algorithm. We tested this mobile-phone based micro-plate reader in a clinical microbiology lab using FDA-approved mumps IgG, measles IgG, and herpes simplex virus IgG (HSV-1 and HSV-2) ELISA tests on 1138 remnant patient samples (roughly 50% training and 50% testing), and achieved an overall accuracy of ~99% or higher for each ELISA test. This handheld and cost-effective platform could be immediately useful for large-scale vaccination monitoring in low-infrastructure settings, and also for other high-throughput disease screening applications at POC.

  17. Dual PD Control Regulation with Nonlinear Compensation for a Ball and Plate System

    Directory of Open Access Journals (Sweden)

    Sergio Galvan-Colmenares

    2014-01-01

    Full Text Available The normal proportional derivative (PD control is modified to a new dual form for the regulation of a ball and plate system. First, to analyze this controller, a novel complete nonlinear model of the ball and plate system is obtained. Second, an asymptotic stable dual PD control with a nonlinear compensation is developed. Finally, the experimental results of ball and plate system are provided to verify the effectiveness of the proposed methodology.

  18. Structural assessments of plate type support system for APR1400 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Anh Tung; Namgung, Ihn, E-mail: inamgung@kings.ac.kr

    2017-04-01

    Highlights: • This paper investigates plate-type support structure for the reactor vessel of the APR 1400. • The tall column supports of APR1400 reactor challenges in seismic and severe accident events. • A plate-type support of reactor vessel was proposed and evaluated based on ASME code. • The plate-type support was assessed to show its higher rigidity than column-type. - Abstract: This paper investigates an alternative form of support structure for the reactor vessel of the APR 1400. The current reactor vessel adopts a four-column support arrangement locating on the cold legs of the vessel. Although having been successfully designed, the tall column structure challenges in seismic events. In addition, for the mitigation of severe accident consequences, the columns inhibit ex-vessel coolant flow, hence the elimination of the support columns proposes extra safety advantages. A plate-type support was proposed and evaluated for the adequacy of meeting the structural stiffness by Finite Element Analysis (FEA) approach. ASME Boiler and Pressure Vessel Code was used to verify the design. The results, which cover thermal and static structural analysis, show stresses are within allowable limits in accordance with the design code. Even the heat conduction area is increased for the plate-type of support system, the results showed that the thermal stresses are within allowable limits. A comparison of natural frequencies and mode shapes for column support and plate-type support were presented as well which showed higher fundamental frequencies for the plate-type support system resulting in greater rigidity of the support system. From the outcome of this research, the plate-type support is proven to be an alternative to current APR column type support design.

  19. Development of simplified nuclear dry plate measuring system

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Y; Ohta, I [Utsunomiya Univ. (Japan). Faculty of Education; Tezuka, I; Tezuka, T; Makino, K

    1981-08-01

    A simplified nuclear dry plate measuring system was developed. The system consists of a microscope, an ITV camera, a monitor TV, an XY tracker and a micro-computer. The signals of the images of tracks in a nuclear dry plate are sent to the XY tracker, and shown on the monitor TV. The XY tracker displays a pointer on the monitor TV, and makes the output signal of its XY coordinate. This output signal is analyzed by the microcomputer. The software for the measuring process is composed of a program system written in BASIC and the machine language. The data in take, the expansion of the range of measurement and the output of analyzed data are controlled by the program. The accuracy of the measurement of coordinate was studied, and was about 0.39 micrometer for 10 micrometer distance.

  20. Addressing Learning Disabilities with UDL and Technology: Strategic Reader

    Science.gov (United States)

    Hall, Tracey E.; Cohen, Nicole; Vue, Ge; Ganley, Patricia

    2015-01-01

    CAST created "Strategic Reader," a technology-based system blending Universal Design for Learning (UDL) and Curriculum-Based Measurement (CBM) in a digital learning environment to improve reading comprehension instruction. This experimental study evaluates the effectiveness of Strategic Reader using two treatment conditions for measuring…

  1. A new microcontroller-based RADFET dosimeter reader

    International Nuclear Information System (INIS)

    Vasović, Nikola D.; Ristić, Goran S.

    2012-01-01

    A new reader for radiation dose measurements using RADFET (pMOSFET) dosemeters has been developed. The threshold voltage (V T ) of the pMOSFETs is measured using a “one-point” method that determines V T as the gate voltage for a given drain current. Using V T , the absorbed dose, which is directly proportional to the threshold voltage shift, is calculated. The reader is based on a low cost 8-bit PIC 18F4520 microcontroller (MCU), and works independently of a personal computer, uses a touch screen and stores the data in microcontroller memory. Good agreement in threshold voltage values, obtained using a high-quality source-measure unit and the reader, was obtained. In addition, the reader can be used for threshold voltage measurement with other types of MOSFETs, especially in long duration experiments, as well as for the real-time measurements in radiotherapy, either as an autonomous system or integrated in a larger monitoring configuration.

  2. Passive microfluidic array card and reader

    Science.gov (United States)

    Dugan, Lawrence Christopher [Modesto, CA; Coleman, Matthew A [Oakland, CA

    2011-08-09

    A microfluidic array card and reader system for analyzing a sample. The microfluidic array card includes a sample loading section for loading the sample onto the microfluidic array card, a multiplicity of array windows, and a transport section or sections for transporting the sample from the sample loading section to the array windows. The microfluidic array card reader includes a housing, a receiving section for receiving the microfluidic array card, a viewing section, and a light source that directs light to the array window of the microfluidic array card and to the viewing section.

  3. JAPANESE READERS (TITLE SUPPLIED).

    Science.gov (United States)

    THREE JAPANESE READERS ARE PRESENTED WHICH CONTAIN VOCABULARY, NOTES, AND DRILL SENTENCES. THE THREE READERS--(1) ARU SARARIIMAN NO ITI-NITI, (2) OTOOSAN WA KAMI-SAMA, AND (3) ARU GAKUSEI NO HANNITI--ARE WRITTEN IN THE ROMAJI ALPHABET. EACH READER HAS A VOCABULARY LISTING WITH ENGLISH EXPLANATIONS AND DRILL SENTENCES. AN ENGLISH WORD DEFINITION…

  4. Evaluating Picture Quality of Image Plates in Digital CR Systems

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Byung Joon [Dept. of Radiological Tecnology, Choonhae College of Health Science, Ulsan (Korea, Republic of); Ji Tae Jeong [Dept. of Radiological Science, Kaya University, Kimhae (Korea, Republic of)

    2011-12-15

    Lab effectively supplemented the effects of outside radiation on image plates in the process of image acquisition of CR (computed radiography) systems and conducted for effective utilization in the case of clinical application. For this, Lab classified the storage places and time periods of image plates and compared and analyzed the differences between small dark spots. Lab also assessed the concentration distribution within the boundaries of images. Lab compared and measured the number of dark spots in a light room and a dark room depending on the storage places of image plates and found that dark spots slightly increased in an image plate when stored in a light room on the first and second days. Dark spots increased in proportion to the length of time stored. In the case of the image plate stored in a dark room, the number of dark spots remarkably decreased. With regard to picture quality as related to the location of image plates, the damage to picture quality could be reduced by locating regions of interest in the center. With regard to differences in sharpness following changes in the thickness of subjects, fewer scatter rays occurred and sharpness improved by reducing the thickness of subjects as much as possible. To get medical images of excellent quality, image plates should be managed effectively and it is desirable to keep images plates in dark iron plate boxes and not to expose them to outside radiation for a long time.

  5. Evaluating Picture Quality of Image Plates in Digital CR Systems

    International Nuclear Information System (INIS)

    Kwak, Byung Joon; Ji Tae Jeong

    2011-01-01

    Lab effectively supplemented the effects of outside radiation on image plates in the process of image acquisition of CR (computed radiography) systems and conducted for effective utilization in the case of clinical application. For this, Lab classified the storage places and time periods of image plates and compared and analyzed the differences between small dark spots. Lab also assessed the concentration distribution within the boundaries of images. Lab compared and measured the number of dark spots in a light room and a dark room depending on the storage places of image plates and found that dark spots slightly increased in an image plate when stored in a light room on the first and second days. Dark spots increased in proportion to the length of time stored. In the case of the image plate stored in a dark room, the number of dark spots remarkably decreased. With regard to picture quality as related to the location of image plates, the damage to picture quality could be reduced by locating regions of interest in the center. With regard to differences in sharpness following changes in the thickness of subjects, fewer scatter rays occurred and sharpness improved by reducing the thickness of subjects as much as possible. To get medical images of excellent quality, image plates should be managed effectively and it is desirable to keep images plates in dark iron plate boxes and not to expose them to outside radiation for a long time.

  6. Microcomputer control of automated TL reader

    International Nuclear Information System (INIS)

    Bjarland, B.

    1980-01-01

    An automatic TL reader has been developed for use within a TLD based personal monitoring service. A 6800 based microcomputer is used for system control, operator communication, calibration and checking of reader operation, and for output of data. The dosimeter identity code is printed in human readable characters on the dosimeter card, and is read by using an optical character recognition unit. The code may include individual sensitivity correction coefficients for the TL chips on the card. The chips are heated with hot nitrogen gas and the thermoluminescence is recorded by a photomultiplier tube circuit, the gain and offset of which are continuously monitored and, when necessary, adjusted, to maintain calibration. The reader may operate in any of seven modes, i.e. reading modes for three types of dosimeters, semiautomatic modes for production of the three types of dosimeters, and a monitor mode. (Auth.)

  7. Performance assessment of imaging plates for the JHR transfer Neutron Imaging System

    Science.gov (United States)

    Simon, E.; Guimbal, P. AB(; )

    2018-01-01

    The underwater Neutron Imaging System to be installed in the Jules Horowitz Reactor (JHR-NIS) is based on a transfer method using a neutron activated beta-emitter like Dysprosium. The information stored in the converter is to be offline transferred on a specific imaging system, still to be defined. Solutions are currently under investigation for the JHR-NIS in order to anticipate the disappearance of radiographic films commonly used in these applications. We report here the performance assessment of Computed Radiography imagers (Imaging Plates) performed at LLB/Orphée (CEA Saclay). Several imaging plate types are studied, in one hand in the configuration involving an intimate contact with an activated dysprosium foil converter: Fuji BAS-TR, Fuji UR-1 and Carestream Flex XL Blue imaging plates, and in the other hand by using a prototypal imaging plate doped with dysprosium and thus not needing any contact with a separate converter foil. The results for these imaging plates are compared with those obtained with gadolinium doped imaging plate used in direct neutron imaging (Fuji BAS-ND). The detection performances of the different imagers are compared regarding resolution and noise. The many advantages of using imaging plates over radiographic films (high sensitivity, linear response, high dynamic range) could palliate its lower intrinsic resolution.

  8. Next Generation Model 8800 Automatic TLD Reader

    International Nuclear Information System (INIS)

    Velbeck, K.J.; Streetz, K.L.; Rotunda, J.E.

    1999-01-01

    BICRON NE has developed an advanced version of the Model 8800 Automatic TLD Reader. Improvements in the reader include a Windows NT TM -based operating system and a Pentium microprocessor for the host controller, a servo-controlled transport, a VGA display, mouse control, and modular assembly. This high capacity reader will automatically read fourteen hundred TLD Cards in one loading. Up to four elements in a card can be heated without mechanical contact, using hot nitrogen gas. Improvements in performance include an increased throughput rate and more precise card positioning. Operation is simplified through easy-to-read Windows-type screens. Glow curves are displayed graphically along with light intensity, temperature, and channel scaling. Maintenance and diagnostic aids are included for easier troubleshooting. A click of a mouse will command actions that are displayed in easy-to-understand English words. Available options include an internal 90 Sr irradiator, automatic TLD calibration, and two different extremity monitoring modes. Results from testing include reproducibility, reader stability, linearity, detection threshold, residue, primary power supply voltage and frequency, transient voltage, drop testing, and light leakage. (author)

  9. Oscillations of a spring-magnet system damped by a conductive plate

    Science.gov (United States)

    Ladera, C. L.; Donoso, G.

    2013-09-01

    We study the motion of a spring-magnet system that oscillates with very low frequencies above a circular horizontal non-magnetizable conductive plate. The magnet oscillations couple with the plate via the Foucault currents induced therein. We develop a simple theoretical model for this magneto-mechanical oscillator, a model that leads to the equation of a damped harmonic oscillator, whose weak attenuation constant depends upon the system parameters, e.g. the electrical conductivity of the constituent material of the plate and its thickness. We present a set of validating experiments, the results of which are predicted with good accuracy by our analytical model. Additional experiments can be performed with this oscillating system or its variants. This oscillator is simple and low-cost, easy to assemble, and can be used in experiments or project works in physics teaching laboratories at the undergraduate level.

  10. Oscillations of a spring–magnet system damped by a conductive plate

    International Nuclear Information System (INIS)

    Ladera, C L; Donoso, G

    2013-01-01

    We study the motion of a spring–magnet system that oscillates with very low frequencies above a circular horizontal non-magnetizable conductive plate. The magnet oscillations couple with the plate via the Foucault currents induced therein. We develop a simple theoretical model for this magneto-mechanical oscillator, a model that leads to the equation of a damped harmonic oscillator, whose weak attenuation constant depends upon the system parameters, e.g. the electrical conductivity of the constituent material of the plate and its thickness. We present a set of validating experiments, the results of which are predicted with good accuracy by our analytical model. Additional experiments can be performed with this oscillating system or its variants. This oscillator is simple and low-cost, easy to assemble, and can be used in experiments or project works in physics teaching laboratories at the undergraduate level. (paper)

  11. High resolution Fresnel zone plate laser alignment system

    International Nuclear Information System (INIS)

    Bressler, V.E.; Fischer, G.E.; Ruland, R.E.; Wang, T.

    1992-03-01

    The existing Fresnel zone plate laser alignment system is currently being extended and upgraded for the Final Focus Test Beam (FFTB). Previously, the resolution of this system has been several tens of micrometers. After the upgrade, the resolution will be a few micrometers. Details of the upgrade as well as simulation and experimental results will be presented

  12. Design and experimental investigation of a Multi-segment plate concentrated photovoltaic solar energy system

    International Nuclear Information System (INIS)

    Wang, Gang; Chen, Zeshao; Hu, Peng

    2017-01-01

    Highlights: • A multi-segment plate concentrated photovoltaic solar energy system was proposed. • A prototype of this new concentrator was developed for experimental investigation. • Experimental investigation results showed a good concentrating uniformity. - Abstract: Solar energy is one of the most promising renewable energies and meaningful for the sustainable development of energy source. A multi-segment plate concentrated photovoltaic (CPV) solar power system was proposed in this paper, the design principle of the multi-segment plate concentrator of this solar power system was given, which could provide uniform solar radiation flux density distribution on solar cells. A prototype of this multi-segment plate CPV solar power system was developed for the experimental study, aiming at the investigations of solar radiation flux density distribution and PV performances under this concentrator design. The experimental results showed that the solar radiation flux density distribution provided by the multi-segment plate concentrator had a good uniformity, and the number and temperature of solar cells both influence the photoelectric transformation efficiency of the CPV solar power system.

  13. Poster — Thur Eve — 02: Measurement of CT radiation profile width using Fuji CR imaging plate raw data

    International Nuclear Information System (INIS)

    Bjarnason, T A; Yang, C J

    2014-01-01

    Measuring the CT collimation width and assessing the shape of the overall profile is a relatively straightforward quality control (QC) measure that impacts both image quality and patient dose, and is often required at acceptance and routine testing. Most CT facilities have access to computed radiography (CR) systems, so performing CT collimation profile assessments using CR plates requires no additional equipment. Previous studies have shown how to effectively use CR plates to measure the radiation profile width. However, a major limitation of the previous work is that the full dynamic range of CR detector plates are not used, since the CR processing technology reduces the dynamic range of the DICOM output to 2 10 , requiring the sensitivity and latitude settings of CR reader to be adjusted to prevent clipping of the CT profile data. Such adjustments to CR readers unnecessarily complicate the QC procedure. These clipping artefacts hinder the ability to accurately assess CT collimation width because the full-width at half maximum value of the penumbras are not properly determined if the maximum dose of the profile is not available. Furthermore, any inconsistencies in the radiation profile shape are lost if the profile plateau is clipped off. In this work we developed an opensource Matlab script for straightforward CT profile width measurements using raw CR data that also allows assessment of the profile shape without clipping, and applied this approach during CT QC

  14. Automatic spent fuel ID number reader (I)

    International Nuclear Information System (INIS)

    Tanabe, S.; Kawamoto, H.; Fujimaki, K.; Kobe, A.

    1991-01-01

    An effective and efficient technique has been developed for facilitating identification works of LWR spent fuel stored in large scale spent fuel storage pools of such as processing plants. Experience shows that there are often difficulties in the implementation of operator's nuclear material accountancy and control works as well as safeguards inspections conducted on spent fuel assemblies stored in deep water pool. This paper reports that the technique is realized as an automatic spent fuel ID number reader system installed on fuel handling machine. The ID number reader system consists of an optical sub-system and an image processing sub-system. Thousands of spent fuel assemblies stored in under water open racks in each storage pool could be identified within relatively short time (e.g. within several hours) by using this combination. Various performance tests were carried out on image processing sub-system in 1990 using TV images obtained from different types of spent fuel assemblies stored in various storage pools of PWR and BWR power stations

  15. A novel portable system for detecting and measuring tritium

    International Nuclear Information System (INIS)

    Barillari, Domenico

    2007-01-01

    A novel tritium detector configuration is described based on the anthracene scintillation method. Tritium-bearing samples are applied to a plate-bearing finely sublimed anthracene crystals and viewed in a field-able PMT-based reader against a standard plate. A microprocessor-based control and signal analysis system delivers a reading with a sensitivity of better than 5 nCi 3 H in approximately 3 min, and 2.3 nCi in 10 min of counting

  16. Triage for Struggling Adolescent Readers

    Science.gov (United States)

    Diamond, Linda J.

    2006-01-01

    To improve achievement for struggling readers in particular, secondary schools must design programs and curricula to address students' lack of background knowledge, delayed English language development, and limited success in reading. In this article, the author presents a systems approach that offers intensive care for the most at-risk students…

  17. The e-Reader — an Educational or an Entertainment Tool? e-Readers in an Academic Setting

    Directory of Open Access Journals (Sweden)

    Peter Ahlroos

    2012-01-01

    Full Text Available In this paper the authors will discuss a pilot project conducted at the Tritonia Academic Library, Vaasa, in Finland, from September 2010 until May 2011. The project was designed to investigate the application of e-readers in academic settings and to learn how teachers and students experience the use of e-readers in academic education. Four groups of students and one group of teachers used Kindle readers for varied periods of time in different courses. The course material and the textbooks were downloaded on the e-readers. The feedback from the participants was collected through questionnaires and teacher interviews. The results suggest that the e-reader is a future tool for learning, though some features need to be improved before e-readers can really enable efficient learning and researching.

  18. Accelerated Reader[R]: What Are the Lasting Effects on the Reading Habits of Middle School Students Exposed to Accelerated Reader[R] in Elementary Grades?

    Science.gov (United States)

    Pavonetti, Linda M.; Brimmer, Kathryn M.; Cipielewski, James F.

    Promoted by effective advertising and disseminated by word of mouth, many schools have adopted Accelerated Reader[R] as a supplementary reading program or as their primary reading program. Accelerated Reader[R]'s philosophy is that by using the system, students are motivated to read more and better books. A study investigated whether seventh grade…

  19. Imaging plate, a new type of x-ray area detector

    International Nuclear Information System (INIS)

    Kamiya, Nobuo; Amemiya, Yoshiyuki; Miyahara, Junji.

    1986-01-01

    In respective fields of X-ray crystallography, for the purpose of the efficient collection of reciprocal space information, two-dimensional X-ray detectors such as multiwire proportional chambers and X-ray television sets have been used together with conventional X-ray films. X-ray films are characterized by uniform sensitivity and high positional resolution over a wide area, but the sensitivity is low, and the range of action and the linearity of the sensitivity is problematic. They require the development process, accordingly lack promptitude. The MWPCs and X-ray television sets are superior in the sensitivity, its linearity, the range of action and promptitude, but interior in the uniformity and resolution to the films. Imaging plate is a new X-ray area detector developed by Fuji Photo Film Co., Ltd., for digital X-ray medical image diagnosis. This detector is superior in all the above mentioned performances, and it seems very useful also for X-ray crystallography. In this paper, the system composed of an imaging plate and its reader is described, and the basic performance as an X-ray area detector and the results of having recorded the diffraction images of protein crystals as the example of applying it to X-ray crystallography are reported. The imaging plate is that the crystalline fluorescent powder of BaFBr doped with Eu 2+ ions is applied on plastic films. (Kako, I.)

  20. 1000-Case Reader Study of Radiologists' Performance in Interpretation of Automated Breast Volume Scanner Images with a Computer-Aided Detection System.

    Science.gov (United States)

    Xu, Xiaojing; Bao, Lingyun; Tan, Yanjuan; Zhu, Luoxi; Kong, Fanlei; Wang, Wei

    2018-05-28

    The objective of our study was to assess, in a reader study, radiologists' performance in interpretation of automated breast volume scanner (ABVS) images with the aid of a computer-aided detection (CADe) system. Our study is a retrospective observer study with the purpose of investigating the effectiveness of using a CADe system as an aid for radiologists in interpretation of ABVS images. The multiple-reader, multiple-case study was designed to compare the diagnostic performance of radiologists with and without CADe. The study included 1000 cases selected from ABVS examinations in our institution in 2012. Among those cases were 206 malignant, 486 benign and 308 normal cases. The cancer cases were consecutive; the benign and normal cases were randomly selected. All malignant and benign cases were confirmed by biopsy or surgery, and normal cases were confirmed by 2-y follow-up. Reader performance was compared in terms of area under the receiver operating characteristic curve, sensitivity and specificity. Additionally, the reading time per case for each reader was recorded. Nine radiologists from our institution participated in the study. Three had more than 8 y of ultrasound experience and more than 4 y of ABVS experience (group A); 3 had more than 5 y of ultrasound experience (group B), and 3 had more than 1 y of ultrasound experience (group C). Both group B and group C had no ABVS experience. The CADe system used was the QVCAD System (QView Medical, Inc., Los Altos, CA, USA). It is designed to aid radiologists in searching for suspicious areas in ABVS images. CADe results are presented to the reader simultaneously with the ABVS images; that is, the radiologists read the ABVS images concurrently with the CADe results. The cases were randomly assigned for each reader into two equal-size groups, 1 and 2. Initially the readers read their group 1 cases with the aid of CADe and their group 2 cases without CADe. After a 1-mo washout period, they re-read their group 1

  1. Cognitive Development in Early Readers.

    Science.gov (United States)

    Briggs, Chari; Elkind, David

    Some studies of early readers are discussed. It is pointed out that study of early readers has relevance for practical and theoretical issues in psychology and education. Of interest in this document are the following questions: (1) Are there any special talents or traits distinguishing early from non-early readers? (2) Do children who read early…

  2. E-book Reader Devices and Libraries

    Directory of Open Access Journals (Sweden)

    Pažur, I.

    2011-03-01

    Full Text Available Most library studies thematically related to electronic books don't consider readers of electronic books. Only in recent years librarians conduct studies in which they want to find out readers' opinions about the possibilities, advantages and disadvantages of reading using e-readers, as well as their possible application in the libraries.User studies of e-readers have shown that their opinion is generally positive, but great attachment to traditional books is still present, e-readers are still seen only as an additional tool for reading. Sony with its e-reader (the latest Reader model Daily and Reader Store online bookstore (http://ebookstore.sony.com/is the only one who cooperate with libraries and has made lending electronic books possible. Cooperation was launched in 2009th,and the New York Public Library was the first library that offered such a service.Cooperation between Sony and libraries, indicates clearly what the near future could be if other online booksellers / publishers begin to follow the model of lending e-books through the libraries over the network. However it is possible that a large online bookstores / publishers consider that the further price reduction of e-readers and electronic books will constantly increase their sales, and in that case lending e-books will be unnecessary.Are the libraries ready for this scenario?

  3. The Automated System for Identification of License Plates of Cars

    Directory of Open Access Journals (Sweden)

    FRATAVCHAN, V.

    2008-04-01

    Full Text Available The paper focuses on the automated traffic rule control system. It examines the basic scheme of the system, basic constituents, principles of constituent interactions, search methods of moving objects, localization, and identification of the license plate.

  4. GMFilter and SXTestPlate: software tools for improving the SNPlex™ genotyping system

    Directory of Open Access Journals (Sweden)

    Schreiber Stefan

    2009-03-01

    Full Text Available Abstract Background Genotyping of single-nucleotide polymorphisms (SNPs is a fundamental technology in modern genetics. The SNPlex™ mid-throughput genotyping system (Applied Biosystems, Foster City, CA, USA enables the multiplexed genotyping of up to 48 SNPs simultaneously in a single DNA sample. The high level of automation and the large amount of data produced in a high-throughput laboratory require advanced software tools for quality control and workflow management. Results We have developed two programs, which address two main aspects of quality control in a SNPlex™ genotyping environment: GMFilter improves the analysis of SNPlex™ plates by removing wells with a low overall signal intensity. It enables scientists to automatically process the raw data in a standardized way before analyzing a plate with the proprietary GeneMapper software from Applied Biosystems. SXTestPlate examines the genotype concordance of a SNPlex™ test plate, which was typed with a control SNP set. This program allows for regular quality control checks of a SNPlex™ genotyping platform. It is compatible to other genotyping methods as well. Conclusion GMFilter and SXTestPlate provide a valuable tool set for laboratories engaged in genotyping based on the SNPlex™ system. The programs enhance the analysis of SNPlex™ plates with the GeneMapper software and enable scientists to evaluate the performance of their genotyping platform.

  5. Mechanical System Analysis of C-Frame for Steel Plate Thickness Gauge

    International Nuclear Information System (INIS)

    Sri Sudadiyo

    2007-01-01

    Nuclear base instrument is not only applied in the area of research such as medical and agriculture sciences, but also in the field of industry especially for thickness gauge. To the present at the steel industry, the gauge that is applied to cut plate thickness using infra-red ray method, it cannot result in accurately data. To solve that case, it is developed a thickness gauge of steel plate by using gamma ray method that it is named C-Frame. This thickness gauge is hoped that it could control in cutting the steel plate by on-line, accurate, and safe, therefore, it could socialize the advanced technology in the nuclear field to support the production process in domestic industries (national industries). The present study yields the calculations of mechanical system of that C-Frame including structure, detector support, source container of radioisotope, and transmission system, be also computed by running Professional Microsoft Fortran Version 5.10, NISA-II program, and AutoCAD program. From the obtained results could be known that the design meets the requirement, so that could be employed properly to measure the thickness of plate in the steel industries. (author)

  6. Faulting and hydration of the Juan de Fuca plate system

    Science.gov (United States)

    Nedimović, Mladen R.; Bohnenstiehl, DelWayne R.; Carbotte, Suzanne M.; Pablo Canales, J.; Dziak, Robert P.

    2009-06-01

    Multichannel seismic observations provide the first direct images of crustal scale normal faults within the Juan de Fuca plate system and indicate that brittle deformation extends up to ~ 200 km seaward of the Cascadia trench. Within the sedimentary layering steeply dipping faults are identified by stratigraphic offsets, with maximum throws of 110 ± 10 m found near the trench. Fault throws diminish both upsection and seaward from the trench. Long-term throw rates are estimated to be 13 ± 2 mm/kyr. Faulted offsets within the sedimentary layering are typically linked to larger offset scarps in the basement topography, suggesting reactivation of the normal fault systems formed at the spreading center. Imaged reflections within the gabbroic igneous crust indicate swallowing fault dips at depth. These reflections require local alteration to produce an impedance contrast, indicating that the imaged fault structures provide pathways for fluid transport and hydration. As the depth extent of imaged faulting within this young and sediment insulated oceanic plate is primarily limited to approximately Moho depths, fault-controlled hydration appears to be largely restricted to crustal levels. If dehydration embrittlement is an important mechanism for triggering intermediate-depth earthquakes within the subducting slab, then the limited occurrence rate and magnitude of intraslab seismicity at the Cascadia margin may in part be explained by the limited amount of water imbedded into the uppermost oceanic mantle prior to subduction. The distribution of submarine earthquakes within the Juan de Fuca plate system indicates that propagator wake areas are likely to be more faulted and therefore more hydrated than other parts of this plate system. However, being largely restricted to crustal levels, this localized increase in hydration generally does not appear to have a measurable effect on the intraslab seismicity along most of the subducted propagator wakes at the Cascadia margin.

  7. A Malaysian Vehicle License Plate Localization and Recognition System

    OpenAIRE

    Ganapathy Velappa; Dennis LUI Wen Lik

    2008-01-01

    Technological intelligence is a highly sought after commodity even in traffic-based systems. These intelligent systems do not only help in traffic monitoring but also in commuter safety, law enforcement and commercial applications. In this paper, a license plate localization and recognition system for vehicles in Malaysia is proposed. This system is developed based on digital images and can be easily applied to commercial car park systems for the use of documenting access of parking services,...

  8. Compact, open-architecture computed radiography system

    International Nuclear Information System (INIS)

    Huang, H.K.; Lim, A.; Kangarloo, H.; Eldredge, S.; Loloyan, M.; Chuang, K.S.

    1990-01-01

    Computed radiography (CR) was introduced in 1982, and its basic system design has not changed. Current CR systems have certain limitations: spatial resolution and signal-to-noise ratios are lower than those of screen-film systems, they are complicated and expensive to build, and they have a closed architecture. The authors of this paper designed and implemented a simpler, lower-cost, compact, open-architecture CR system to overcome some of these limitations. The open-architecture system is a manual-load-single-plate reader that can fit on a desk top. Phosphor images are stored in a local disk and can be sent to any other computer through standard interfaces. Any manufacturer's plate can be read with a scanning time of 90 second for a 35 x 43-cm plate. The standard pixel size is 174 μm and can be adjusted for higher spatial resolution. The data resolution is 12 bits/pixel over an x-ray exposure range of 0.01-100 mR

  9. Postmodern theories about readers in electronic environment

    Directory of Open Access Journals (Sweden)

    Ivanka Kuić

    2015-03-01

    Full Text Available Introductory part of the paper discusses theories about readers in the last decades of the 20th century. In particular, two big theoretical schools are discussed: aesthetic reception theory and reader-response-criticism movement. Readers are a subject of very different scientific disciplines: literature theory, sociology, anthropology, book history and library science. The idea that a reader is an essential subject for future life of a literary work is common to all theorists. By constructing the theory about a reader, theorists have thought about the reader who uses the conventions of printed text. The issue whether these concepts correspond to electronic surroundings is discussed. Characteristics of the hypertext are emphasized as a new paradigm, and also the issue weather readers enjoys in hypertextual fiction. In conclusion, paper expands the virtual dimension of Isers's theory about interaction between the text and the reader, and also Fish's concept of “interpretative community” which may be constituted on the Internet as a flexible virtual community.

  10. Relative motions of the Australian, Pacific and Antarctic plates estimated by the Global Positioning System

    Science.gov (United States)

    Larson, Kristine M.; Freymueller, Jeff

    1995-01-01

    Global Positioning System (GPS) measurements spanning approximately 3 years have been used to determine velocities for 7 sites on the Australian, Pacific and Antarctic plates. The site velocities agree with both plate model predictions and other space geodetic techniques. We find no evidence for internal deformation of the interior of the Australian plate. Wellington, New Zealand, located in the Australian-Pacific plate boundary zone, moves 20 +/- 5 mm/yr west-southwest relative to the Australian plate. Its velocity lies midway between the predicted velocities of the two plates. Relative Euler vectors for the Australia-Antarctica and Pacific-Antarctica plates agree within one standard deviation with the NUVEL-1A predictions.

  11. Computer-aided detection of lung nodules on multidetector CT in concurrent-reader and second-reader modes: A comparative study

    International Nuclear Information System (INIS)

    Matsumoto, Sumiaki; Ohno, Yoshiharu; Aoki, Takatoshi; Yamagata, Hitoshi; Nogami, Munenobu; Matsumoto, Keiko; Yamashita, Yoshiko; Sugimura, Kazuro

    2013-01-01

    Purpose: To compare the reading times and detection performances of radiologists in concurrent-reader and second-reader modes of computer-aided detection (CAD) for lung nodules on multidetector computed tomography (CT). Materials and Methods: Fifty clinical multidetector CT datasets containing nodules up to 20 mm in diameter were retrospectively collected. For the detection and rating of non-calcified nodules larger than 4 mm in diameter, 6 radiologists (3 experienced radiologists and 3 resident radiologists) independently interpreted these datasets twice, once with concurrent-reader CAD and once with second-reader CAD. The reference standard of nodules in the datasets was determined by the consensus of two experienced chest radiologists. The reading times and detection performances in the two modes of CAD were statistically compared, where jackknife free-response receiver operating characteristic (JAFROC) analysis was used for the comparison of detection performances. Results: Two hundreds and seven nodules constituted the reference standard. Reading time was significantly shorter in the concurrent-reader mode than in the second-reader mode, with the mean reading time for the 6 radiologists being 132 s with concurrent-reader CAD and 210 s with second-reader CAD (p < 0.01). JAFROC analysis revealed no significant difference between the detection performances in the two modes, with the average figure-of-merit value for the 6 radiologists being 0.70 with concurrent-reader CAD and 0.72 with second-reader CAD (p = 0.35). Conclusion: In CAD for lung nodules on multidetector CT, the concurrent-reader mode is more time-efficient than the second-reader mode, and there can be no significant difference between the two modes in terms of detection performance of radiologists

  12. Centralized Gap Clearance Control for Maglev Based Steel-Plate Conveyance System

    Directory of Open Access Journals (Sweden)

    GUNEY, O. F.

    2017-08-01

    Full Text Available The conveyance of steel-plates is one of the potential uses of the magnetic levitation technology in industry. However, the electromagnetic levitation systems inherently show nonlinear feature and are unstable without an active control. Well-known U-shaped or E-shaped electromagnets cannot provide redundant levitation with multiple degrees of freedom. In this paper, to achieve the full redundant levitation of the steel plate, a quadruple configuration of U shaped electromagnets has been proposed. To resolve the issue of instability and attain more robust levitation, a centralized control algorithm based on a modified PID controller (I PD is designed for each degree of freedom by using the Manabe canonical polynomial technique. The model of the system is carried out using electromechanical energy conversion princi¬ples and verified by 3-D FEM analysis. An experimental bench is built up to test the system performance under trajectory tracking and external disturbance excitation. The results confirm the effectiveness of the proposed system and the control approach to obtain a full redundant levitation even in case of disturbances. The paper demonstrates the feasibility of the con¬veyance of steel plates by using the quadruple configuration of U-shaped electromagnets and shows the merits of I-PD controller both in stabilization and increased robust levitation.

  13. Reader performance in visual assessment of breast density using visual analogue scales: Are some readers more predictive of breast cancer?

    Science.gov (United States)

    Rayner, Millicent; Harkness, Elaine F.; Foden, Philip; Wilson, Mary; Gadde, Soujanya; Beetles, Ursula; Lim, Yit Y.; Jain, Anil; Bundred, Sally; Barr, Nicky; Evans, D. Gareth; Howell, Anthony; Maxwell, Anthony; Astley, Susan M.

    2018-03-01

    Mammographic breast density is one of the strongest risk factors for breast cancer, and is used in risk prediction and for deciding appropriate imaging strategies. In the Predicting Risk Of Cancer At Screening (PROCAS) study, percent density estimated by two readers on Visual Analogue Scales (VAS) has shown a strong relationship with breast cancer risk when assessed against automated methods. However, this method suffers from reader variability. This study aimed to assess the performance of PROCAS readers using VAS, and to identify those most predictive of breast cancer. We selected the seven readers who had estimated density on over 6,500 women including at least 100 cancer cases, analysing their performance using multivariable logistic regression and Receiver Operator Characteristic (ROC) analysis. All seven readers showed statistically significant odds ratios (OR) for cancer risk according to VAS score after adjusting for classical risk factors. The OR was greatest for reader 18 at 1.026 (95% Cl 1.018-1.034). Adjusted Area Under the ROC Curves (AUCs) were statistically significant for all readers, but greatest for reader 14 at 0.639. Further analysis of the VAS scores for these two readers showed reader 14 had higher sensitivity (78.0% versus 42.2%), whereas reader 18 had higher specificity (78.0% versus 46.0%). Our results demonstrate individual differences when assigning VAS scores; one better identified those with increased risk, whereas another better identified low risk individuals. However, despite their different strengths, both readers showed similar predictive abilities overall. Standardised training for VAS may improve reader variability and consistency of VAS scoring.

  14. Design of Stress-Strain Measuring System for Bulldozing Plate Based on Virtual Instrument Technology

    International Nuclear Information System (INIS)

    Xu, S C; Li, J Q; Zhang, R

    2006-01-01

    Soil is a kind of discrete, multiphase compound that is composed of soil particles, liquid and air. When soil is disturbed by bulldozing plate, the mechanical behavior of the soil will become very complex. Based on the law of action and reaction, the dynamic mechanical behavior of disturbed soil was indirectly analyzed by measuring and studying the forces on the bulldozing plate by soil currently, so a stress-strain virtual measuring system for bulldozing plate, which was designed by the graphical programming language DASYLab, was used to measure the horizontal force Fz acting on the bulldozing plate. In addition, during the course of design, the experimental complexities and the interferential factors influencing on signal logging were analyzed when bulldozing plate worked, so the anti-jamming methods of hardware and software technology were adopted correlatively. In the end, the horizontal force Fz was analyzed with Error Theory, the result shown that the quantificational analysis of Fz were identical to the qualitative results of soil well, and the error of the whole test system is under 5 percent, so the tress-strain virtual measuring system was stable and credible

  15. Chipless RFID reader architecture

    CERN Document Server

    Karmakar, Nemai Chandra; Kalansuriya, Prasanna

    2013-01-01

    In the era of information communication technology (ICT), radio frequency identification (RFID) has been going through tremendous development. RFID technology has the potential of replacing barcodes due to its large information carrying capacity, flexibility in operations, and applications. The deployment of RFID has been hindered by its cost. However, with the advent of low powered ICs, energy scavenging techniques, and low-cost chipless tags, RFID technology has achieved significant development. This book addresses the new reader architecture, presents fundamentals of chipless RFID systems,

  16. Biomechanical evaluation of a new MatrixMandible plating system on cadaver mandibles.

    Science.gov (United States)

    Gateno, Jaime; Cookston, Christopher; Hsu, Sam Sheng-Pin; Stal, Drew N; Durrani, Salim K; Gold, Jonathan; Ismaily, Sabir; Alexander, Jerry W; Noble, Philip C; Xia, James J

    2013-11-01

    Current mandibular plating systems contain a wide range of plates and screws needed for the treatment of mandibular reconstruction and mandibular fractures. The authors' hypothesis was that a single diameter screw could be used in all applications in a plating system. Therefore, the purpose of this study was to test if the 2.0-mm locking screws could replace the 2.4-mm screws to stabilize a 2.5-mm-thick reconstruction plate in the treatment of mandibular discontinuity. Thirty-six fresh human cadaveric mandibles were used: 18 were plated using 2.0-mm locking screws (experimental) and the other 18 were plated using 2.4-mm locking screws (control). Each group was further divided into 3 subgroups based on the site of loading application: the ipsilateral (right) second premolar region, the central incisal region, and the contralateral (left) first molar region. The same ipsilateral (right) mandibular angular discontinuity was created by the same surgeon. The mandible was mounted on a material testing machine. The micromotions between the 2 segments, permanent and elastic displacements, were recorded after incremental ramping loads. The magnitude of screw back-out and the separation between plate and bone were recorded using a laser scanner (resolution, 0.12 mm) before and after the loading applications. The data were processed. Descriptive analyses and a general linear model for repeated measures analysis of variance were performed. There was no statistically significant difference in permanent displacement (mean, 1.16 and 0.82 mm, respectively) between the 2.0-mm and 2.4-mm screw groups. There also was no statistically significant difference in elastic displacement between the 2 groups (mean, 1.48 and 1.21 mm, respectively). Finally, there were no statistically significant differences in screw back-out or separation between plate and bone between the 2 groups. All means for screw back-out and separation between screw and bone for each group were judged within the

  17. Auditory signal design for automatic number plate recognition system

    NARCIS (Netherlands)

    Heydra, C.G.; Jansen, R.J.; Van Egmond, R.

    2014-01-01

    This paper focuses on the design of an auditory signal for the Automatic Number Plate Recognition system of Dutch national police. The auditory signal is designed to alert police officers of suspicious cars in their proximity, communicating priority level and location of the suspicious car and

  18. Crash course in readers' advisory

    CERN Document Server

    Orr, Cynthia

    2014-01-01

    One of the key services librarians provide is helping readers find books they'll enjoy. This ""crash course"" will furnish you with the basic, practical information you need to excel at readers' advisory (RA) for adults and teens.

  19. To evaluate the efficacy of biodegradable plating system for fixation of maxillofacial fractures: A prospective study

    OpenAIRE

    Bali, Rishi K.; Sharma, Parveen; Jindal, Shalu; Gaba, Shivani

    2013-01-01

    Aims: The present study was undertaken to evaluate the efficacy of biodegradable plating system for fixation of maxillofacial fractures and to study the morbidity associated with the use of biodegradable plates and screws. Materials and Methods: This prospective study consisted of 10 patients with maxillofacial fractures requiring open reduction and internal fixation. Fractures with infection, comminuted and pathological fractures were excluded. All were plated with biodegradable system (Inio...

  20. A neural network based artificial vision system for licence plate recognition.

    Science.gov (United States)

    Draghici, S

    1997-02-01

    This paper presents a neural network based artificial vision system able to analyze the image of a car given by a camera, locate the registration plate and recognize the registration number of the car. The paper describes in detail various practical problems encountered in implementing this particular application and the solutions used to solve them. The main features of the system presented are: controlled stability-plasticity behavior, controlled reliability threshold, both off-line and on-line learning, self assessment of the output reliability and high reliability based on high level multiple feedback. The system has been designed using a modular approach. Sub-modules can be upgraded and/or substituted independently, thus making the system potentially suitable in a large variety of vision applications. The OCR engine was designed as an interchangeable plug-in module. This allows the user to choose an OCR engine which is suited to the particular application and to upgrade it easily in the future. At present, there are several versions of this OCR engine. One of them is based on a fully connected feedforward artificial neural network with sigmoidal activation functions. This network can be trained with various training algorithms such as error backpropagation. An alternative OCR engine is based on the constraint based decomposition (CBD) training architecture. The system has showed the following performances (on average) on real-world data: successful plate location and segmentation about 99%, successful character recognition about 98% and successful recognition of complete registration plates about 80%.

  1. The Routledge Applied Linguistics Reader

    Science.gov (United States)

    Wei, Li, Ed.

    2011-01-01

    "The Routledge Applied Linguistics Reader" is an essential collection of readings for students of Applied Linguistics. Divided into five sections: Language Teaching and Learning, Second Language Acquisition, Applied Linguistics, Identity and Power and Language Use in Professional Contexts, the "Reader" takes a broad…

  2. Microcomputer control of automated TLD reader

    International Nuclear Information System (INIS)

    Bjarland, Bert.

    1979-10-01

    The interfacing electronics, the control algorithms and the developed programs of a 6800 microcomputer controlled automated TLD reader are described. The TL reading system is implemented with a photomultiplier tube and a charge-to-pulse converter. The gain of the TL reading system is controlled through the use of a temperature compensated LED reference light source. Automatic compensation of PM tube dark current is optional. The short term stability of TL readings is better than 3 %. (author)

  3. The differential effects of position, ad and reader characteristics on readers' processing of newspaper ads

    NARCIS (Netherlands)

    Smit, E.G.; Neijens, P.C.; Heath, R.

    2013-01-01

    Building on previous research on the processing of newspaper ads, this comprehensive field study, with 26,556 newspaper readers and 290 unique advertisements, investigated the combined effects of position in the newspaper, ad characteristics and reader characteristics. The results show a

  4. Erosion Modeling of the High Contraction Chromium Plated Crusader Gun System

    National Research Council Canada - National Science Library

    Sopok, S

    2003-01-01

    Thermal-chemical- mechanical erosion modeling predictions are given for the high contraction chromium plated Crusader gun system based on extensive cannon firing, inspection, characterization, and experimental data...

  5. Separation of Cadmium in Printing Industrial Liquid Waste by Electromagnetic Plating System

    International Nuclear Information System (INIS)

    Prayitno

    2007-01-01

    To prevent incidence of environmental contamination and its effect to society health and other mortal, poisonous and dangerous substance waste have to be managed peculiarly by minimizing or eliminating the nature of its danger. Various processing have been developed to degrade the waste rate for example sorption, flotation, flocculation, etc., but the yield of the degradation of metal rate can not fulfill permanent standard quality of liquid waste. Because of the reason explained before, its important to make a new breakthrough as one of final phase processing alternative named reductant electromagnetic plating. Waste to be degraded in this research is cadmium. In fact cadmium represent the foregain metal for human and is not require at all in human body for metabolism process. Though plenty of cadmium exploited, but during for centuries it caused the food poisoned because this metal insoluble in organic acid. Separation of cadmium rate with electromagnetic plating influenced by time process, concentration, current strength, and type of electrode plate. Result of research indicate that the optimum time processing if using plate of copper electrode is during 30 minute and using plate of aluminium electrode is during 20 minute. Optimum of strong current that used in process of electromagnetic plating is only 0.8 Ampere and concentration effective is 5 mg / L. The most effective type of electrode plate for reducing cadmium from waste by using electromagnetic plating is aluminium. Appliance of electromagnetic plating system is very compatible used for the reduction of cadmium and others metal for feed concentration (1 - 5) mg/L .at the price efficiency of reduction is (95 - 98) %, standard quality of liquid waste is (0.05 - 1) mg/L. (author)

  6. A cost-effective smartphone-based antimicrobial susceptibility test reader for drug resistance testing (Conference Presentation)

    Science.gov (United States)

    Feng, Steve W.; Tseng, Derek; Di Carlo, Dino; Garner, Omai B.; Ozcan, Aydogan

    2017-03-01

    Antimicrobial susceptibility testing (AST) is commonly used for determining microbial drug resistance, but routine testing, which can significantly reduce the spread of multi-drug resistant organisms, is not regularly performed in resource-limited and field-settings due to technological challenges and lack of trained diagnosticians. We developed a portable cost-effective smartphone-based colorimetric 96-well microtiter plate (MTP) reader capable of automated AST without the need for a trained diagnostician. This system is composed of a smartphone used in conjunction with a 3D-printed opto-mechanical attachment, which holds a set of inexpensive light-emitting-diodes and fiber-optic cables coupled to the 96-well MTP for enabling the capture of the transmitted light through each well by the smartphone camera. Images of the MTP plate are captured at multiple exposures and uploaded to a local or remote server (e.g., a laptop) for automated processing/analysis of the results using a custom-designed smartphone application. Each set of images are combined to generate a high dynamic-range image and analyzed for well turbidity (indicative of bacterial growth), followed by interpretative analysis per plate to determine minimum inhibitory concentration (MIC) and drug susceptibility for the specific bacterium. Results are returned to the originating device within 1 minute and shown to the user in tabular form. We demonstrated the capability of this platform using MTPs prepared with 17 antibiotic drugs targeting Gram-negative bacteria and tested 82 patient isolate MTPs of Klebsiella pneumoniae, achieving well turbidity accuracy of 98.19%, MIC accuracy of 95.15%, and drug susceptibility interpretation accuracy of 99.06%, meeting the FDA defined criteria for AST.

  7. E-Book Readers in Higher Education

    Directory of Open Access Journals (Sweden)

    Arthur N. Olsen

    2013-04-01

    Full Text Available This article reports on a research project at the University of Agder that has studied the use of e-readers as a tool for academic study. E-readers (Kindle DX and iPad were loaded with texts from required reading lists in five courses with 94 participating students. Initially, 87 students responded to the invitation to participate in a survey, but eventually 13 of these submissions had to be removed, as the degree of completion was not sufficient. The final response rate achieved was 79%. Students were in general positive to the use of e-readers but still show a preference for print on paper as the best medium for serious academic study. When reading books, 54% preferred print, 28% a combination of print and e-reader, and finally only 11% were satisfied solely using an e-reader. The iPad scored significantly better than the Kindle DX on tasks that required active interaction with the texts such as highlighting and note taking.

  8. An imaging method of wavefront coding system based on phase plate rotation

    Science.gov (United States)

    Yi, Rigui; Chen, Xi; Dong, Liquan; Liu, Ming; Zhao, Yuejin; Liu, Xiaohua

    2018-01-01

    Wave-front coding has a great prospect in extending the depth of the optical imaging system and reducing optical aberrations, but the image quality and noise performance are inevitably reduced. According to the theoretical analysis of the wave-front coding system and the phase function expression of the cubic phase plate, this paper analyzed and utilized the feature that the phase function expression would be invariant in the new coordinate system when the phase plate rotates at different angles around the z-axis, and we proposed a method based on the rotation of the phase plate and image fusion. First, let the phase plate rotated at a certain angle around the z-axis, the shape and distribution of the PSF obtained on the image surface remain unchanged, the rotation angle and direction are consistent with the rotation angle of the phase plate. Then, the middle blurred image is filtered by the point spread function of the rotation adjustment. Finally, the reconstruction images were fused by the method of the Laplacian pyramid image fusion and the Fourier transform spectrum fusion method, and the results were evaluated subjectively and objectively. In this paper, we used Matlab to simulate the images. By using the Laplacian pyramid image fusion method, the signal-to-noise ratio of the image is increased by 19% 27%, the clarity is increased by 11% 15% , and the average gradient is increased by 4% 9% . By using the Fourier transform spectrum fusion method, the signal-to-noise ratio of the image is increased by 14% 23%, the clarity is increased by 6% 11% , and the average gradient is improved by 2% 6%. The experimental results show that the image processing by the above method can improve the quality of the restored image, improving the image clarity, and can effectively preserve the image information.

  9. Ultrahigh resolution radiation imaging system using an optical fiber structure scintillator plate.

    Science.gov (United States)

    Yamamoto, Seiichi; Kamada, Kei; Yoshikawa, Akira

    2018-02-16

    High resolution imaging of radiation is required for such radioisotope distribution measurements as alpha particle detection in nuclear facilities or high energy physics experiments. For this purpose, we developed an ultrahigh resolution radiation imaging system using an optical fiber structure scintillator plate. We used a ~1-μm diameter fiber structured GdAlO 3 :Ce (GAP) /α-Al 2 O 3 scintillator plate to reduce the light spread. The fiber structured scintillator plate was optically coupled to a tapered optical fiber plate to magnify the image and combined with a lens-based high sensitivity CCD camera. We observed the images of alpha particles with a spatial resolution of ~25 μm. For the beta particles, the images had various shapes, and the trajectories of the electrons were clearly observed in the images. For the gamma photons, the images also had various shapes, and the trajectories of the secondary electrons were observed in some of the images. These results show that combining an optical fiber structure scintillator plate with a tapered optical fiber plate and a high sensitivity CCD camera achieved ultrahigh resolution and is a promising method to observe the images of the interactions of radiation in a scintillator.

  10. Enhancing the Usability of an Optical Reader System to Support Point-of-Care Rapid Diagnostic Testing: An Iterative Design Approach.

    Science.gov (United States)

    Hohenstein, Jess; O'Dell, Dakota; Murnane, Elizabeth L; Lu, Zhengda; Erickson, David; Gay, Geri

    2017-11-21

    In today's health care environment, increasing costs and inadequate medical resources have created a worldwide need for more affordable diagnostic tools that are also portable, fast, and easy to use. To address this issue, numerous research and commercial efforts have focused on developing rapid diagnostic technologies; however, the efficacy of existing systems has been hindered by usability problems or high production costs, making them infeasible for deployment in at-home, point-of-care (POC), or resource-limited settings. The aim of this study was to create a low-cost optical reader system that integrates with any smart device and accepts any type of rapid diagnostic test strip to provide fast and accurate data collection, sample analysis, and diagnostic result reporting. An iterative design methodology was employed by a multidisciplinary research team to engineer three versions of a portable diagnostic testing device that were evaluated for usability and overall user receptivity. Repeated design critiques and usability studies identified a number of system requirements and considerations (eg, software compatibility, biomatter contamination, and physical footprint) that we worked to incrementally incorporate into successive system variants. Our final design phase culminated in the development of Tidbit, a reader that is compatible with any Wi-Fi-enabled device and test strip format. The Tidbit includes various features that support intuitive operation, including a straightforward test strip insertion point, external indicator lights, concealed electronic components, and an asymmetric shape, which inherently signals correct device orientation. Usability testing of the Tidbit indicates high usability for potential user communities. This study presents the design process, specification, and user reception of the Tidbit, an inexpensive, easy-to-use, portable optical reader for fast, accurate quantification of rapid diagnostic test results. Usability testing suggests

  11. Development of Portable Automatic Number Plate Recognition System on Android Mobile Phone

    Science.gov (United States)

    Mutholib, Abdul; Gunawan, Teddy S.; Chebil, Jalel; Kartiwi, Mira

    2013-12-01

    The Automatic Number Plate Recognition (ANPR) System has performed as the main role in various access control and security, such as: tracking of stolen vehicles, traffic violations (speed trap) and parking management system. In this paper, the portable ANPR implemented on android mobile phone is presented. The main challenges in mobile application are including higher coding efficiency, reduced computational complexity, and improved flexibility. Significance efforts are being explored to find suitable and adaptive algorithm for implementation of ANPR on mobile phone. ANPR system for mobile phone need to be optimize due to its limited CPU and memory resources, its ability for geo-tagging image captured using GPS coordinates and its ability to access online database to store the vehicle's information. In this paper, the design of portable ANPR on android mobile phone will be described as follows. First, the graphical user interface (GUI) for capturing image using built-in camera was developed to acquire vehicle plate number in Malaysia. Second, the preprocessing of raw image was done using contrast enhancement. Next, character segmentation using fixed pitch and an optical character recognition (OCR) using neural network were utilized to extract texts and numbers. Both character segmentation and OCR were using Tesseract library from Google Inc. The proposed portable ANPR algorithm was implemented and simulated using Android SDK on a computer. Based on the experimental results, the proposed system can effectively recognize the license plate number at 90.86%. The required processing time to recognize a license plate is only 2 seconds on average. The result is consider good in comparison with the results obtained from previous system that was processed in a desktop PC with the range of result from 91.59% to 98% recognition rate and 0.284 second to 1.5 seconds recognition time.

  12. A Sign Language Screen Reader for Deaf

    Science.gov (United States)

    El Ghoul, Oussama; Jemni, Mohamed

    Screen reader technology has appeared first to allow blind and people with reading difficulties to use computer and to access to the digital information. Until now, this technology is exploited mainly to help blind community. During our work with deaf people, we noticed that a screen reader can facilitate the manipulation of computers and the reading of textual information. In this paper, we propose a novel screen reader dedicated to deaf. The output of the reader is a visual translation of the text to sign language. The screen reader is composed by two essential modules: the first one is designed to capture the activities of users (mouse and keyboard events). For this purpose, we adopted Microsoft MSAA application programming interfaces. The second module, which is in classical screen readers a text to speech engine (TTS), is replaced by a novel text to sign (TTSign) engine. This module converts text into sign language animation based on avatar technology.

  13. Report Card on Basal Readers.

    Science.gov (United States)

    Goodman, Kenneth S.; And Others

    This report examines the nature of the modern basal reader, its economics, and use. First, the report provides a history showing how the confluence of business principles, positivistic science, and behavioral psychology led to the transformation of reading textbooks into basal readers. Next, the report examines objectives and subjective factors…

  14. When High-Capacity Readers Slow Down and Low-Capacity Readers Speed Up: Working Memory and Locality Effects.

    Science.gov (United States)

    Nicenboim, Bruno; Logačev, Pavel; Gattei, Carolina; Vasishth, Shravan

    2016-01-01

    We examined the effects of argument-head distance in SVO and SOV languages (Spanish and German), while taking into account readers' working memory capacity and controlling for expectation (Levy, 2008) and other factors. We predicted only locality effects, that is, a slowdown produced by increased dependency distance (Gibson, 2000; Lewis and Vasishth, 2005). Furthermore, we expected stronger locality effects for readers with low working memory capacity. Contrary to our predictions, low-capacity readers showed faster reading with increased distance, while high-capacity readers showed locality effects. We suggest that while the locality effects are compatible with memory-based explanations, the speedup of low-capacity readers can be explained by an increased probability of retrieval failure. We present a computational model based on ACT-R built under the previous assumptions, which is able to give a qualitative account for the present data and can be tested in future research. Our results suggest that in some cases, interpreting longer RTs as indexing increased processing difficulty and shorter RTs as facilitation may be too simplistic: The same increase in processing difficulty may lead to slowdowns in high-capacity readers and speedups in low-capacity ones. Ignoring individual level capacity differences when investigating locality effects may lead to misleading conclusions.

  15. Development of the system for checking attendance of the lecture at the university using the card reader

    OpenAIRE

    田中,武; 大村,道郎; 楠,茂之; 安井,良親; 山田,明宏

    2003-01-01

    Development of the system for checking attendance of the lecture at the university using the card reader was demonstrated. The rate of checking attendance of the lecture was about 4 to 12 students per minute. The break time of lecture at the Hiroshima Institute of Technology was 10 minute. Therefore, it is possible to check about 40 students' attendance of the lecture for the break time. Also, the probability that check exactly attendance was about 50%. The real time system for checking atten...

  16. Plate Motion and Crustal Deformation Estimated with Geodetic Data from the Global Positioning System

    Science.gov (United States)

    Argus, Donald F.; Heflin, Michael B.

    1995-01-01

    We use geodetic data taken over four years with the Global Positioning System (GPS) to estimate: (1) motion between six major plates and (2) motion relative to these plates of ten sites in plate boundary zones. The degree of consistency between geodetic velocities and rigid plates requires the (one-dimensional) standard errors in horizontal velocities to be approx. 2 mm/yr. Each of the 15 angular velocities describing motion between plate pairs that we estimate with GPS differs insignificantly from the corresponding angular velocity in global plate motion model NUVEL-1A, which averages motion over the past 3 m.y. The motion of the Pacific plate relative to both the Eurasian and North American plates is observed to be faster than predicted by NUVEL-1A, supporting the inference from Very Long B ase- line Interferometry (VLBI) that motion of the Pacific plate has speed up over the past few m.y. The Eurasia-North America pole of rotation is estimated to be north of NUVEL-1A, consistent with the independent hypothesis that the pole has recently migrated northward across northeast Asia to near the Lena River delta. Victoria, which lies above the main thrust at the Cascadia subduction zone, moves relative to the interior of the overriding plate at 30% of the velocity of the subducting plate, reinforcing the conclusion that the thrust there is locked beneath the continental shelf and slope.

  17. Scoring sacroiliac joints by magnetic resonance imaging. A Multiple-reader reliability experiment

    DEFF Research Database (Denmark)

    Landewé, RB; Hermann, KG; van der Heijde, DM

    2005-01-01

    Magnetic resonance imaging (MRI) of the sacroiliac (SI) joints and the spine is increasingly important in the assessment of inflammatory activity and structural damage in clinical trials with patients with ankylosing spondylitis (AS). We investigated inter-reader reliability and sensitivity...... for 'depth' and 'intensity,' and the fifth method included the SPARCC slice with the maximum score. Inter-reader reliability was investigated by calculating intraclass correlation coefficients (ICC) for all readers together and for all possible reader pairs. Sensitivity to change was investigated...... values close to zero (no agreement) and highest observed values over 0.80 (excellent agreement). In general, agreement of status scores was somewhat better than agreement of change scores, and agreement of the comprehensive SPARCC scoring system was somewhat better than agreement of the more condensed...

  18. The StorySpinner Sculptural Reader

    OpenAIRE

    Hooper, Clare; Weal, Mark

    2005-01-01

    This demo is of a hypertext reading system called StorySpinner. It follows the sculptural hypertext methodology and has been used as a test bed for experimenting with the authoring of narrative flow in automatically generated stories. Readers are able to select and read one of two available stories. Reading a story involves selecting tarot cards which are mapped to chunks of story text based on possible interpretations of the cards and information concerning current story state.

  19. Hybrid heat recovery - flat plate Stirling engine system

    International Nuclear Information System (INIS)

    Bogdanizh, A.M.; Budin, R.; Sutlovizh, I.

    2000-01-01

    In this paper, the possibility of process condensate heat recovery for boiler water preheating as well as for combined heat and power production for chosen process in textile industry has been investigated. The garment industry requires low pressure process steam or hot water for which production expensive fossil fuel should be used. Fuel usage can be reduced by various energy conservation methods. During the process a great quantity of hot condensate or waste hot water is rejected in the sewage system. To reduce heat wastes and improve technological process this condensate could be returned to the boiler for feed water preheating. When 60% condensate is returned to the steam generator about 8 % natural gas is saved. The rest of the condensate should be used for driving low temperature flat plate Stirling motor the advantage of the flat plate Stirling engine is ability to work at low temperatures. This engine produces electrical energy which can put in motion an electrogenerator in the same plant. While Stirling engine can be used electrical power and economical effect could be much greater using such a hybrid system the process waste heat is not only converted into useful work but at the same time thermal pollution is greatly diminished. (Author)

  20. [Survey among readers of the Tijdschrift voor Psychiatrie].

    Science.gov (United States)

    Brandt-Dominicus, J C; van Harten, P N

    2006-01-01

    The editorial board has defined the objectives of this journal as follows: to provide its readers with refreshing information, to report the results of scientific research and to build bridges between research and everyday practice. To find out what readers want and whether they support the board's objectives, and to use this information in planning the contents of future issues of the journal. All readers were invited to complete a questionnaire either on paper or via the website. Questionnaires were completed by 255 readers (response rate 5.7%). The average rating on a 5-point Likert scale was 3.8. Thematic issues and issues devoted to book reviews were given a high rating. There seems to be a demandfor evidence-based medicine, the inclusion of scientific results reported in other journals and practice-based articles. No significant differences were found between the views expressed by readers who had previously submitted an article for publication and those who had not, nor between Flemish readers and Dutch readers. The website was not visited very often. The Tijdschrift voor Psychiatrie is greatly appreciated by its readers. They are largely in agreement with the objectives formulated by the editorial board. Thematic issues are highly rated and many subjects are mentioned by the readers for future issues. The low response to the survey can affect its representativity. The editorial board will take readers' wishes into consideration when selecting material for future issues of the journal.

  1. Observations in the Past of Solar System Bodies with MAO NANU Plate Archives

    Science.gov (United States)

    Sergeeva, T. P.; Golovnya, V. V.; Yizhakevych, E. M.; Shatokhina, S. V.; Sergeev, A. V.

    2006-04-01

    The plate archives of the Main Astronomical Observatory of the National Academy of Sciences of Ukraine contain more than 100,000 images of minor planets with magnitude up to 16.7m. About 10% of the minor planets, found on our archival plates, were discovered many years after taking the plates. So we can rediscover them by so called "observation in the past" and obtain their positions for improvement of the dynamical models of their motions. Other Solar System bodies for which we try to get "observation in the past" are the external planets satellites. The criteria for chosen objects, the search methods, identification and determination of positions are discussed. The first results of the asteroids and the external planet satellites search in MAO plate archives are presented.

  2. 21 CFR 886.5800 - Ophthalmic bar reader.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic bar reader. 886.5800 Section 886.5800...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5800 Ophthalmic bar reader. (a) Identification. An ophthalmic bar reader is a device that consists of a magnifying lens intended for use by a...

  3. To evaluate the efficacy of biodegradable plating system for fixation of maxillofacial fractures: A prospective study.

    Science.gov (United States)

    Bali, Rishi K; Sharma, Parveen; Jindal, Shalu; Gaba, Shivani

    2013-07-01

    The present study was undertaken to evaluate the efficacy of biodegradable plating system for fixation of maxillofacial fractures and to study the morbidity associated with the use of biodegradable plates and screws. This prospective study consisted of 10 patients with maxillofacial fractures requiring open reduction and internal fixation. Fractures with infection, comminuted and pathological fractures were excluded. All were plated with biodegradable system (Inion CPS) using standard plating principles and observed for a total period of 24 weeks. Characteristics of the fractures, ease of use of bioresorbable plate/screw system and post operative complications were assessed. Of total 10 patients, eight patients were of midface fracture and two pediatric patients with mandibular fracture, with nine male and one female. The mean age was 32.8 years. Out of 20 plates and 68 screws applied to the 10 fractures sites; there were three incidences of screw breakage with no other intraoperative difficulties. Paresthesia of the infraorbital nerve was present in two patients, and recovered completely in four weeks after surgery. Fracture reduction was considered to be satisfactory in all cases. One patient developed postsurgical infection and was managed with oral antibiotics and analgesics. Favorable healing can be observed through the use of biodegradable plates and screws to stabilize selected midface fractures in patients of all ages, as well as mandible fractures in early childhood, however further studies with more sample size are required.

  4. Microfractionation revisited: a 1536 well high resolution screening assay

    NARCIS (Netherlands)

    Giera, M.A.; Heus, F.; Janssen, L.; Kool, J.; Lingeman, H.; Irth, H.

    2009-01-01

    The aim of the here presented study was to combine high performance liquid chromatography with plate reader technology in order to overcome certain drawbacks of integrated online systems as well as offline plate reader approaches. The described method combines an "at-line" enzyme assay for the

  5. Making a Commitment to Strategic-Reader Training

    Institute of Scientific and Technical Information of China (English)

    FREDRICKA L. STOLLER; REIKO KOMIYAMA

    2013-01-01

    Skilled readers by definition are strategic; they are able to use a repertoire of reading strategies , flexibly and in meaningful combinations , to achieve their reading comprehension goals . Thus , one of the aims of foreign and second language (L2) reading curricula should be to move students toward becoming more strategic readers . This curricular orientation can be best achieved when a strong commitment is made to strategic-reader training as a regular and consistent component of instruction across the curriculum . To explore this stance , we examine the reading strategies used by skilled readers , contrast teaching strategies with training strategic readers ( i .e . , strategic-reader training) , and examine five strategic-reader training approaches from first language contexts that can be adapted by L2 professionals to enhance the reading instruction offered in their L 2 classes . The five approaches targeted for exploration include Directed Reading-Thinking Activity , Reciprocal Teaching , Transactional Strategies Instruction , Questioning the Author , and Concept-Oriented Reading Instruction . Though distinct from one another , they all acknowledge the importance of explicit explanations about strategies (or reminders about the use of select strategies) , teacher modeling , scaffolded tasks , active student engagement , student practice , classroom discussions of strategy use , and the gradual release of responsibility to students who eventually decide for themselves (and/or with peers) when , where , and why to use which strategies to achieve their comprehension goals . We conclude with a discussion of the challenges , and suggestions for overcoming them , that L 2 teachers and students often face in making a commitment to strategic-reader training .

  6. Dose reader CD-02

    International Nuclear Information System (INIS)

    Jakowiuk, A.; Kaluska, I.; Machaj, B.

    2005-01-01

    Dose Reader CD-02 is designed for measurement of dose from a long narrow band of dosimetric foil used for check up and control of electron beam dose during sterilization of materials and products on conveyor belt. Irradiated foil after processing (heating) is inserted into foil driving (moving) system and when the foil is moved across focused light beam the absorbed dose is measured and displayed at the same time at computer monitor (in form of a diagram). The absorbed dose is measured on the principle of light attenuation at selected light wavelength (foil absorbance is measured). (author)

  7. Laterally Loaded Nail-Plates

    DEFF Research Database (Denmark)

    Nielsen, Jacob; Rathkjen, Arne

    Load-displacement curves from about 200 short-term and laterally loaded nail-plate joints are analysed. The nail-plates are from Gang-Nail Systems, type GNA 20 S. The test specimens and the measuring systems are described. The tests are divided into 32 different series. The influence of the number...

  8. Conceptual design of control rod regulating system for plate type fuels of Triga-2000 reactor

    International Nuclear Information System (INIS)

    Eko Priyono; Saminto

    2016-01-01

    Conceptual design of the control rod regulating system for plate type fuel of TRIGA-2000 reactor has been made. Conceptual design of the control rod regulating system for plate type fuel of TRIGA-2000 reactor was made with refer to study result of instrument and control system which is used in BATAN'S reactor. Conceptual design of the control rod regulating system for plate type fuel of TRIGA-2000 reactor consist of 4 segments that is control panel, translator, driver and display. Control panel is used for regulating, safety and display control rod, translator is used for signal processing from control panel, driver is used for driving control rod and display is used for display control rod level position. The translator was designed in 2 modes operation i.e operation by using PLC modules and IC TTL modules. These conceptual design can be used as one of reference of control rod regulating system detail design. (author)

  9. Improvements of RGD3 TLD reader

    International Nuclear Information System (INIS)

    Zhao Jianxing; Wang Jiaqi; Li Yuanfang; Wu Furong; Xiao Wuyun

    1999-01-01

    The author summarized the main features of the improved RGD3 TLD reader. Through a large number of experiments some persuasive data are obtained, which show that an remarkable improvement has been achieved, especially in its stability to the standard illuminates, data dispersivity, and effectiveness to glow curves analysis. Working with the newly developed data processing software, the comprehensive performance of the whole system will be enhanced greatly

  10. An Effective Scheduling-Based RFID Reader Collision Avoidance Model and Its Resource Allocation via Artificial Immune Network

    OpenAIRE

    Wang, Shanjin; Li, Zhonghua; He, Chunhui; Li, Jianming

    2016-01-01

    Radio frequency identification, that is, RFID, is one of important technologies in Internet of Things. Reader collision does impair the tag identification efficiency of an RFID system. Many developed methods, for example, the scheduling-based series, that are used to avoid RFID reader collision, have been developed. For scheduling-based methods, communication resources, that is, time slots, channels, and power, are optimally assigned to readers. In this case, reader collision avoidance is equ...

  11. Performance evaluation of vertical feed fully automated TLD badge reader using 0.8 and 0.4 mm teflon embedded CaSO4:Dy dosimeters

    International Nuclear Information System (INIS)

    Ratna, P.; More, Vinay; Kulkarni, M.S.

    2012-01-01

    The personnel monitoring of more than 80,000 radiation workers in India is at present carried out by semi-automated TLD badge Reader systems (TLDBR-7B) developed by Radiation Safety Systems Division, Bhabha Atomic Research Centre. More than 60 such reader systems are in use in all the personnel monitoring centers in the country. Radiation Safety Systems Division also developed the fully automated TLD badge reader based on a new TLD badge having built-in machine readable ID code (in the form of 16x3 hole pattern). This automated reader is designed with minimum of changes in the electronics and mechanical hardware in the semiautomatic version (TLDBR-7B) so that such semi-automatic readers can be easily upgraded to the fully automated versions by using the new TLD badge with ID code. The reader was capable of reading 50 TLD cards in 90 minutes. Based on the feedback from the users, a new model of frilly automated TLD badge Reader (model VEFFA-10) is designed which is an improved version of the previously reported fully Automated TLD badge reader. This VEFFA-10 PC based Reader incorporates vertical loading of TLD bards having machine readable ID code. In this new reader, a vertical rack, which can hold 100 such cards, is mounted from the right side of the reader system. The TLD card falls into the channel by gravity from where it is taken to the reading position by rack and pinion method. After the readout, the TLD card is dropped in a eject tray. The reader employs hot N 2 gas heating method and the gas flow is controlled by a specially designed digital gas flow meter on the front panel of the reader system. The system design is very compact and simple and card stuck up problem is totally eliminated in the reader system. The reader has a number of self-diagnostic features to ensure a high degree of reliability. This paper reports the performance evaluation of the Reader using 0.4 mm thick Teflon embedded CaSO 4 :Dy TLD cards instead of 0.8 mm cards

  12. CUZCO READER.

    Science.gov (United States)

    SOLA, DONALD F.

    WRITTEN TO ACCOMPANY THE SPOKEN CUZCO QUECHUA MATERIALS, THIS READER CONSISTS OF SHORT SELECTIONS ACTUALLY RECORDED IN THE FIELD AND REPRESENTING SEVERAL SUBDIALECTS SPOKEN IN RURAL SECTIONS OF THE DEPARTMENT OF CUZCO, PERU. INCLUDED ARE DIALOGS, STORIES, SONGS, CULTURAL SELECTIONS, AND INTERVIEWS. THE FORMAT GIVES THE CUZCO QUECHUA DIALECT AND…

  13. Cyber Literature: A Reader – Writer Interactivity

    Directory of Open Access Journals (Sweden)

    Fathu Rahman

    2017-06-01

    Full Text Available Cyber Literature is a term known since the coming of the internet which brings a convenience, changing habit and world view. This study is a survey-based on respondents’ opinion about the existence of cyber literature on social media; of its benefit and impact to the reader. This study limits to the poems on Facebook group. The reason is simple; it favors the short form. For the study of a reader-writer interactivity in cyber literature is more likely on poetry. The approach is reader response literary theory with focus on the reader-writer interactivity on Facebook. This research aimed at uncovering the motivation of readers to response the uploaded text, the reasons why they love it and what its advantages. The results showed that cyber literature is successfully to introduce a new literary genre as well as to raise motivation and creativity of authors to make use the internet space.

  14. Implications of unchanged detection criteria with CAD as second reader of mammograms

    International Nuclear Information System (INIS)

    Bornefalk, Hans

    2006-01-01

    In this paper we address the use of computer-aided detection (CAD) systems as second readers in mammography. The approach is based on Bayesian decision theory and its implication for the choice of optimal operating points. The choice of a certain operating point along an ROC curve corresponds to a particular tradeoff between false positives and missed cancers. By minimizing a total risk function given this tradeoff, we determine optimal decision thresholds for the radiologist and CAD system when CAD is used as a second reader. We show that under very general circumstances, the performance of the sequential system is improved if the decision threshold of the latent human decision variable is increased compared to what it would have been in the absence of the CAD system. This means that an initial stricter decision criterion should be applied by the radiologist when CAD is used as a second reader than otherwise. First and foremost, the results in this paper should be interpreted qualitatively, but an attempt is made at quantifying the effect by tuning the model to a prospective study evaluating the use of CAD as a second reader. By making some necessary and plausible assumptions, we are able to estimate the effect of the resulting suboptimal operating point. In this study of 12 860 women, we estimate that a 15% reduction in callbacks for masses could have been achieved with only about a 1.5% relative decrease in sensitivity compared to that without using a stricter initial criterion by the radiologist. For microcalcifications the corresponding values are 7% and 0.2%

  15. The active reader: what is active?

    NARCIS (Netherlands)

    Woerkum, van C.

    2012-01-01

    How writers can adapt to their readers is an important issue in effective communication strategies, and certainly crucial in the case of functional texts. Therefore, it is necessary to look at how readers are constructed as partners in a communication co-production. This article explores the concept

  16. Identification of damage in plates using full-field measurement with a continuously scanning laser Doppler vibrometer system

    Science.gov (United States)

    Chen, Da-Ming; Xu, Y. F.; Zhu, W. D.

    2018-05-01

    An effective and reliable damage identification method for plates with a continuously scanning laser Doppler vibrometer (CSLDV) system is proposed. A new constant-speed scan algorithm is proposed to create a two-dimensional (2D) scan trajectory and automatically scan a whole plate surface. Full-field measurement of the plate can be achieved by applying the algorithm to the CSLDV system. Based on the new scan algorithm, the demodulation method is extended from one dimension for beams to two dimensions for plates to obtain a full-field operating deflection shape (ODS) of the plate from velocity response measured by the CSLDV system. The full-field ODS of an associated undamaged plate is obtained by using polynomials with proper orders to fit the corresponding full-field ODS from the demodulation method. A curvature damage index (CDI) using differences between curvatures of ODSs (CODSs) associated with ODSs that are obtained by the demodulation method and the polynomial fit is proposed to identify damage. An auxiliary CDI obtained by averaging CDIs at different excitation frequencies is defined to further assist damage identification. An experiment of an aluminum plate with damage in the form of 10.5% thickness reduction in a damage area of 0.86% of the whole scan area is conducted to investigate the proposed method. Six frequencies close to natural frequencies of the plate and one randomly selected frequency are used as sinusoidal excitation frequencies. Two 2D scan trajectories, i.e., a horizontally moving 2D scan trajectory and a vertically moving 2D scan trajectory, are used to obtain ODSs, CODSs, and CDIs of the plate. The damage is successfully identified near areas with consistently high values of CDIs at different excitation frequencies along the two 2D scan trajectories; the damage area is also identified by auxiliary CDIs.

  17. When high-capacity readers slow down and low-capacity readers speed up: Working memory and locality effects

    Directory of Open Access Journals (Sweden)

    Bruno eNicenboim

    2016-03-01

    Full Text Available We examined the effects of argument-head distance in SVO and SOV languages (Spanish and German, while taking into account readers’ working memory capacity and controlling for expectation (Levy, 2008 and other factors. We predicted only locality effects, that is, a slow-down produced by increased dependency distance (Gibson, 2000; Lewis & Vasishth, 2005. Furthermore, we expected stronger locality effects for readers with low working memory capacity. Contrary to our predictions, low-capacity readers showed faster reading with increased distance, while high-capacity readers showed locality effects. We suggest that while the locality effects are compatible with memory-based explanations, the speedup of low-capacity readers can be explained by an increased probability of retrieval failure. We present a computational model based on ACT-R built under the previous assumptions, which is able to give a qualitative account for the present data and can be tested in future research. Our results suggest that in some cases, interpreting longer RTs as indexing increased processing difficulty and shorter RTs as facilitation may be too simplistic: The same increase in processing difficulty may lead to slowdowns in high-capacity readers and speedups in low-capacity ones. Ignoring individual level capacity differences when investigating locality effects may lead to misleading conclusions.

  18. WellReader: a MATLAB program for the analysis of fluorescence and luminescence reporter gene data.

    Science.gov (United States)

    Boyer, Frédéric; Besson, Bruno; Baptist, Guillaume; Izard, Jérôme; Pinel, Corinne; Ropers, Delphine; Geiselmann, Johannes; de Jong, Hidde

    2010-05-01

    Fluorescent and luminescent reporter gene systems in combination with automated microplate readers allow real-time monitoring of gene expression on the population level at high precision and sampling density. This generates large amounts of data for the analysis of which computer tools are missing to date. We have developed WellReader, a MATLAB program for the analysis of fluorescent and luminescent reporter gene data. WellReader allows the user to load the output files of microplate readers, remove outliers, correct for background effects and smooth and fit the data. Moreover, it computes biologically relevant quantities from the measured signals, notably promoter activities and protein concentrations, and compares the resulting expression profiles of different genes under different conditions. WellReader is available under a LGPL licence at http://prabi1.inrialpes.fr/trac/wellreader.

  19. Dosimetric properties of the 'Pille' portable, wide dose range TLD reader

    International Nuclear Information System (INIS)

    Szabo, P.P.; Feher, I.; Deme, S.; Szabo, B.; Vagvoelgyi, J.

    1986-01-01

    The dosimetric properties of a portable TLD reader are described. The TLD system named 'Pille' or 'moth' consists of a lightweight battery-operated portable TLD reader and its CaSO 4 :Dy bulb dosemeters. The reproducibility of the TLD system at constant temperature was found to be better than + -2%, and the mean time between failures exceeded 5 years. The dose range of the system is wide, covering more than 6 orders of magnitude, from 5 μGy to 10 Gy. The energy dependence of the CaSO 4 :Dy bulb dosemeters is less than + - 20% above 100 keV in the energy compensation capsules. Without additional annealing, the bulb dosemeters can be re-used at least 100 times, which is an important aspect during in situ measurements. (author)

  20. Using Readers' Theater with Multicultural Literature

    Science.gov (United States)

    Weisenburger, Stephanie

    2009-01-01

    The author needed a way to engage her students in the reading process and found one extremely successful strategy: using Readers' Theater. Readers' Theater "dramatizes" literature through a classroom performance and provides visual and oral stimulus to students who are not used to using imagination to appreciate literary texts. It involves a…

  1. Process Synchronization with Readers and Writers Revisited

    OpenAIRE

    Kawash, Jalal

    2005-01-01

    The readers-writers problem is one of the very well known problems in concurrency theory. It was first introduced by Courtois et.al. in 1971 [1] and requires the synchronization of processes trying to read and write a shared resource. Several readers are allowed to access the resource simultaneously, but a writer must be given exclusive access to that resource. Courtois et.al. gave semaphore-based solutions to what they called the first and second readers-writers problems. Both of their solut...

  2. Plated copper substrates for the LASL Antares CO2 laser system

    International Nuclear Information System (INIS)

    Blevins, D.J.; Munroe, J.L.

    1979-01-01

    Antares is a large carbon-dioxide laser system presently under construction at the Los Alamos Scientific Laboratory (LASL). Antares will be part of the LASL High Energy Gas Laser Facility (HEGLF). Its purpose will be to investigate inertial confinement fusion with light of 10.6-μm wavelength. Most of the optics comprising Antares will be reflectors and, for many reasons, copper is the material of choice. The mirrors range in size from 2.5 cm in diameter to 45 cm in diameter. The copper must be very pure to help maximize damage threshold, making plated copper an attractive solution. The final mirror should be very stable, i.e., characterized by very low microcreep. This makes an alloy a more suitable substrate candidate than pure copper. For Antares, all of the smaller mirrors will be made of copper plated onto an aluminum-bronze substrate, and all of the larger mirrors will be made of copper plated onto aluminum alloy 2124. This paper discusses how this design was arrived at and the methods used to assure a satisfactory mirror

  3. LESS SKILLED READERS HAVE LESS EFFICIENT SUPPRESSION MECHANISMS.

    Science.gov (United States)

    Gernsbacher, Morton Ann

    1993-09-01

    One approach to understanding the component processes and mechanisms underlying adult reading skill is to compare the performance of more skilled and less skilled readers on laboratory experiments. The results of some recent experiments employing this approach demonstrate that less skilled adult readers suppress less efficiently the inappropriate meanings of ambiguous words (e.g., the playing card vs. garden tool meanings of spade ), the incorrect forms of homophones (e.g., patients vs. patience ), the typical-but-absent members of scenes (e.g., a tractor in a farm scene), and words superimposed on pictures. Less skilled readers are not less efficient in activating contextually appropriate information; in fact, they activate contextually appropriate information more strongly than more skilled readers do. Therefore, one conclusion that can be drawn from these experiments is that less skilled adult readers suffer from less efficient suppression mechanisms.

  4. Cadmium plating replacements

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, M.J.; Groshart, E.C.

    1995-03-01

    The Boeing Company has been searching for replacements to cadmium plate. Two alloy plating systems seem close to meeting the needs of a cadmium replacement. The two alloys, zinc-nickel and tin-zinc are from alloy plating baths; both baths are neutral pH. The alloys meet the requirements for salt fog corrosion resistance, and both alloys excel as a paint base. Currently, tests are being performed on standard fasteners to compare zinc-nickel and tin-zinc on threaded hardware where cadmium is heavily used. The Hydrogen embrittlement propensity of the zinc-nickel bath has been tested, and just beginning for the tin-zinc bath. Another area of interest is the electrical properties on aluminum for tin-zinc and will be discussed. The zinc-nickel alloy plating bath is in production in Boeing Commercial Airplane Group for non-critical low strength steels. The outlook is promising that these two coatings will help The Boeing Company significantly reduce its dependence on cadmium plating.

  5. How to diagnose any type of TLD Reader?; Como diagnosticar cualquier tipo de TLD Reader?

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, Manuel Lopez; Garcia, Jose A. Tamayo; Gil, Alex Vergara; Lores, Stefan Gutierrez; Acosta, Andry Romero; Villanueva, Gilberto Alonso, E-mail: manolo@cphr.edu.cu, E-mail: jotag@cphr.edu.cu, E-mail: alex@cphr.edu.cu, E-mail: stefan@cphr.edu.cu, E-mail: andy@cphr.edu.cu, E-mail: gilberto@cphr.edu.cu [Centro de Proteccion e Higiene de las Radiaciones (CPHR), La Habana (Cuba)

    2013-07-01

    The acquisition of know how of practical experiences obtained in the repair and maintenance of readers TLD RADOS for five years of work and the request by the International Atomic Energy for signing new Research Contracts (CRP), made possible the CRP 13328, in which the specialist is committed in the course of a year, to deliver educational software in order to train personnel associated with the operation of the TLD readers RADOS. Due to the importance of continuous transfer of knowledge for new generations of technicians and specialists who join our laboratories, the idea came when the first interactive CD that grouped 19 videos, divided into three blocks was ready: learning, repair and maintenance; it was suggested to expand the training for any TLD reader. Thus a much more complete than the first version package emerged. 7 cases were subsequently published in an IAEA TECDOC, 1599 were included.

  6. EVALUATION OF A KILN INCORPORATING AN OSCILLATING PLATE AIRFLOW SYSTEM

    OpenAIRE

    Campean,Mihaela; Marinescu,Ion; Ispas,Mihai

    2003-01-01

    Boards of spruce (Picea abies) were dried in a pilot kiln with an oscillating plate that provides -"alternating air movement in the stack". The paper outlines the airflow concept and provides results for drying time and quality.It is suggested that the system has certain advantages which make it suitable as an alternative to conventional drying, especially for small-sized enterprises

  7. An Effective Scheduling-Based RFID Reader Collision Avoidance Model and Its Resource Allocation via Artificial Immune Network

    Directory of Open Access Journals (Sweden)

    Shanjin Wang

    2016-01-01

    Full Text Available Radio frequency identification, that is, RFID, is one of important technologies in Internet of Things. Reader collision does impair the tag identification efficiency of an RFID system. Many developed methods, for example, the scheduling-based series, that are used to avoid RFID reader collision, have been developed. For scheduling-based methods, communication resources, that is, time slots, channels, and power, are optimally assigned to readers. In this case, reader collision avoidance is equivalent to an optimization problem related to resource allocation. However, the existing methods neglect the overlap between the interrogation regions of readers, which reduces the tag identification rate (TIR. To resolve this shortage, this paper attempts to build a reader-to-reader collision avoidance model considering the interrogation region overlaps (R2RCAM-IRO. In addition, an artificial immune network for resource allocation (RA-IRO-aiNet is designed to optimize the proposed model. For comparison, some comparative numerical simulations are arranged. The simulation results show that the proposed R2RCAM-IRO is an effective model where TIR is improved significantly. And especially in the application of reader-to-reader collision avoidance, the proposed RA-IRO-aiNet outperforms GA, opt-aiNet, and PSO in the total coverage area of readers.

  8. Reader-Responses of Pregnant Adolescents and Teenage Mothers to Young Adult Novels Portraying Protagonists with Problems Similar and Dissimilar to the Readers'.

    Science.gov (United States)

    Poe, Elizabeth Ann

    Applying reader response theory, a study explored the responses of 19 pregnant adolescents and teenage mothers to two dissimilar young adult novels, one about teenage pregnancy and one about adolescent alcoholism. Quantitative analysis, using a modified version of the Purves-Rippere (1968) system, and qualitative analysis of written answers to…

  9. Reader responses to literary depictions of rape

    NARCIS (Netherlands)

    E.M. Koopman (Emy); M. Hilscher (Michelle); G.C. Cupchik (Gerald)

    2012-01-01

    textabstractThis study explored reader responses to different literary depictions of rape. Four literary excerpts were used and divided as aesthetic versus nonaesthetic (style) and allusive versus explicit (detail). The general question was how readers would react to literary fragments depicting

  10. Control design and robustness analysis of a ball and plate system by using polynomial chaos

    Energy Technology Data Exchange (ETDEWEB)

    Colón, Diego [University of São Paulo, Polytechnic School, LAC -PTC, São Paulo (Brazil); Balthazar, José M. [São Paulo State University - Rio Claro Campus, Rio Claro (Brazil); Reis, Célia A. dos [São Paulo State University - Bauru Campus, Bauru (Brazil); Bueno, Átila M.; Diniz, Ivando S. [São Paulo State University - Sorocaba Campus, Sorocaba (Brazil); Rosa, Suelia de S. R. F. [University of Brasilia, Brasilia (Brazil)

    2014-12-10

    In this paper, we present a mathematical model of a ball and plate system, a control law and analyze its robustness properties by using the polynomial chaos method. The ball rolls without slipping. There is an auxiliary robot vision system that determines the bodies' positions and velocities, and is used for control purposes. The actuators are to orthogonal DC motors, that changes the plate's angles with the ground. The model is a extension of the ball and beam system and is highly nonlinear. The system is decoupled in two independent equations for coordinates x and y. Finally, the resulting nonlinear closed loop systems are analyzed by the polynomial chaos methodology, which considers that some system parameters are random variables, and generates statistical data that can be used in the robustness analysis.

  11. Development of a nickel plated aluminum krypton-81m target system.

    Science.gov (United States)

    Alrumayan, F; Okarvi, S M; Nagatsu, K; Yanbawi, S; Aljammaz, I

    2017-03-01

    A fully automated system was developed to produce rubidium-81 ( 81 Rb), based on the nat Kr (p, n) 81 Rb reaction. The energy incident on the target was 26MeV. Only 6MeV was stopped inside the gas and the remainder was stopped by a specially designed flange. The target body was characterized by its conical shape and its inner walls were chemically plated with 100±10µm of nickel (Ni). Ni is advantageous as a fairly good conductor of heat whose surface can resist solutions. Additionally, the Ni plated target allowed potassium chloride to dissolve 81 Rb, with no further effect on the target body. The system produced 81 Rb with a production yield of approximately 4.5mCi/µAh, which is close to the calculated expected yield of 5.3mCi/µAh. The system is able to deliver reliable and reproducible radioactivity for patients and can be operated up to 1500µAh before preventive maintenance is due. Key steps in designing the 81 Rb target for selected energy ranges are reported here. Copyright © 2016. Published by Elsevier Ltd.

  12. Metacognition and Reading: Comparing Three Forms of Metacognition in Normally Developing Readers and Readers with Dyslexia.

    Science.gov (United States)

    Furnes, Bjarte; Norman, Elisabeth

    2015-08-01

    Metacognition refers to 'cognition about cognition' and includes metacognitive knowledge, strategies and experiences (Efklides, 2008; Flavell, 1979). Research on reading has shown that better readers demonstrate more metacognitive knowledge than poor readers (Baker & Beall, 2009), and that reading ability improves through strategy instruction (Gersten, Fuchs, Williams, & Baker, 2001). The current study is the first to specifically compare the three forms of metacognition in dyslexic (N = 22) versus normally developing readers (N = 22). Participants read two factual texts, with learning outcome measured by a memory task. Metacognitive knowledge and skills were assessed by self-report. Metacognitive experiences were measured by predictions of performance and judgments of learning. Individuals with dyslexia showed insight into their reading problems, but less general knowledge of how to approach text reading. They more often reported lack of available reading strategies, but groups did not differ in the use of deep and surface strategies. Learning outcome and mean ratings of predictions of performance and judgments of learning were lower in dyslexic readers, but not the accuracy with which metacognitive experiences predicted learning. Overall, the results indicate that dyslexic reading and spelling problems are not generally associated with lower levels of metacognitive knowledge, metacognitive strategies or sensitivity to metacognitive experiences in reading situations. 2015 The Authors. Dyslexia Published by John Wiley & Sons Ltd.

  13. The application of PS printing plate with Biimidazole photosensitive initiating systems

    International Nuclear Information System (INIS)

    Li Lidong; Xu Jinqi; Gao Fang; Yang Yongyuan

    1999-01-01

    The ultraviolet photosensitive initiating system is composed of 4,4'-bis(N,N'-dimethyl-amino)benzophenone(MK), 2-chlorohexaarylbiimidazole(o-C1-HABI) and a hydrogen donor co-initiator n-dodecyl mercaptan(SH). Under the irradiation by high pressure mercury lamp, the relationship between the photo-polymerization rate of MMA and the concentration of each component of the system, including MK, o-C1-HABI and SH, was studied. The excellent results have been obtained through studying the system's application on PS lithographic printing plate

  14. Image quality in conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Aichinger, U.; Boehner, C.; Dobritz, M.; Bautz, W.; Saebel, M.

    2000-01-01

    Purpose: Comparison of image quality between conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique. Materials and Methods: Radiograms of a RMI-mammography phantom were acquired using a conventional film screen system, two digital storage plate systems and two digital systems in CCD-technique. Additionally, the radiograms of one digital phosphor storage plate system were post-processed emphasizing contrast and included in the comparison. Results: The detectability of details was the best with the digital mammography in CCD-technique in comparison with the conventional film screen technique resp. digital phosphor storage plate in magnification technique. Conclusions: Based on these results there is the possibility to replace the conventional film screen system by further studies - this has to be confirmed. (orig.) [de

  15. Stability of midface fracture repair using absorbable plate and screw system pilot holes drilled and pin placement at angles other than 90°.

    Science.gov (United States)

    Carron, Michael A; Zuliani, Giancarlo; Pereira, Lucio; Abuhamdan, Maher; Thibault, Adrianna; Dau, Nathan; Bir, Cynthia

    2014-01-01

    Conventional plating systems use titanium plates for fixation of fractures, with benefits of strength and biocompatibility. However, titanium plates require that screws be placed at a 90° angle to the pilot holes. In the midface, this becomes extremely difficult. Today, a variety of craniomaxillofacial osteosynthesis systems are available, including resorbable plating systems. Specifically, the KLS Martin Sonic Weld system ultrasonically fuses the plate and the head of the pin when placed and will fill the pilot hole grooves completely even at less than 90° angles, which provides a tremendous advantage in midface fracture repair. To determine if the KLS Martin Sonic Weld system provides plate-screw construct stability in human heads even when placed at acute angles at the midface buttresses. DESIGN, SETTING, AND SPECIMENS: Twenty cadaveric head specimens with the mandible removed were prepared by creating osteotomies in the midface buttresses bilaterally. Specimens were defleshed and placed in a 2-part testing rig to hold and position the head for testing in a standard material testing system. Testing was performed at the Wayne State University Bioengineering test laboratories, Detroit, Michigan, using an Instron device and high-speed camera. Specimens were plated on one side of the midface using the KLS Martin Sonic Weld system with pilot holes and pins placed at 90° angles. On the contralateral side, the buttresses were plated with the KLS Martin Sonic Weld system at 60°, 45°, and 30° angles. Data were collected using the TDAS data acquisition system and were compared with matched pairs within each specimen. Ultrasonically vibrated pins placed into absorbable mini-plates at less than 90° angles with the KLS Martin Sonic Weld system were compared with the same amount of stress as the system placed at a 90° angle before demonstrating plate-screw construct failure. RESULTS Fifty-seven paired tests were collected, with 114 total tests. Twenty failures were

  16. Incremental picture archiving and communication system (PACS) - an appraisal

    International Nuclear Information System (INIS)

    Nagle, K.

    2000-01-01

    Digital storage phosphor radiography is slowly being introduced in Australia with more sites making the conversion from film/screen to computed radiography or a fully integrated Picture Archiving and Communication System (PACS). St Vincent's Hospital, Melbourne (SVHM) introduced partial PACS for general radiography in June 1996. This involved networking two Fuji CR Image Plate Readers and an existing Kodak KESPR400 Reader with viewing stations strategically placed in Medical Imaging, Casualty and the Intensive and Coronary Care units. No long-term storage device or archive facility was purchased. This installation coincided with the relocation of the Medical Imaging Department (MID) to a fully equipped new site as well as the introduction of the Kestral Radiology Management System. The transition has involved significant changes to the department's design, workflow and the radiographers' work practices. Copyright (1999) Australian Institute of Radiography

  17. E-Books on the Mobile E-Reader

    Directory of Open Access Journals (Sweden)

    Chulyun Kim

    2013-01-01

    Full Text Available The market for e-books has been established during the past several years. Many e-book readers are commercially available, and millions of e-book titles are available for purchase or free download. E-paper technology has matured enough to be used as the screen for dedicated e-book readers which make reading possible with the familiar feel of reading printed books. In this paper, we provide a comprehensive review of the status of the e-book, including the architecture and features of e-book readers, market adoption and e-book industry ecosystem.

  18. Semantic and phonological coding in poor and normal readers.

    Science.gov (United States)

    Vellutino, F R; Scanlon, D M; Spearing, D

    1995-02-01

    Three studies were conducted evaluating semantic and phonological coding deficits as alternative explanations of reading disability. In the first study, poor and normal readers in second and sixth grade were compared on various tests evaluating semantic development as well as on tests evaluating rapid naming and pseudoword decoding as independent measures of phonological coding ability. In a second study, the same subjects were given verbal memory and visual-verbal learning tasks using high and low meaning words as verbal stimuli and Chinese ideographs as visual stimuli. On the semantic tasks, poor readers performed below the level of the normal readers only at the sixth grade level, but, on the rapid naming and pseudoword learning tasks, they performed below the normal readers at the second as well as at the sixth grade level. On both the verbal memory and visual-verbal learning tasks, performance in poor readers approximated that of normal readers when the word stimuli were high in meaning but not when they were low in meaning. These patterns were essentially replicated in a third study that used some of the same semantic and phonological measures used in the first experiment, and verbal memory and visual-verbal learning tasks that employed word lists and visual stimuli (novel alphabetic characters) that more closely approximated those used in learning to read. It was concluded that semantic coding deficits are an unlikely cause of reading difficulties in most poor readers at the beginning stages of reading skills acquisition, but accrue as a consequence of prolonged reading difficulties in older readers. It was also concluded that phonological coding deficits are a probable cause of reading difficulties in most poor readers.

  19. Orion Boiler Plate Airdrop Test System

    Science.gov (United States)

    Machin, Ricardo A.; Evans, Carol T.

    2013-01-01

    On the 29th of February 2012 the Orion Capsule Parachute Assembly System (CPAS) project attempted to perform an airdrop test of a boilerplate test article for the second time. The first attempt (Cluster Development Test 2, July 2008) to deliver a similar boilerplate from a C-17 using the Low Velocity Air Drop (LVAD) technique resulted in the programmer parachute failing to properly inflate, the test article failing to achieve the desired test initiation conditions, and the test article a total loss. This paper will pick up where the CDT-2 failure investigation left off, describing the test technique that was adopted, and outline the modeling that was performed to gain confidence that the second attempt would be successful. The second boiler plate test (Cluster Development Test 3-3) was indeed a complete success and has subsequently been repeated several times, allowing the CPAS project to proceed with the full scale system level development testing required to integrate the hardware to the first Entry Flight Test vehicle as well as go into the Critical Design Review with minimum risk and a mature design.

  20. Performance evaluation of three computed radiography systems using methods recommended in American Association of Physicists in Medicine Report 93

    International Nuclear Information System (INIS)

    Muhogora, Wilbroad; Padovani, Renato; Bonutti, Faustino; Msaki, Peter; Kazema, R.

    2011-01-01

    The performances of three clinical computed radiography (CR) systems (Agfa CR 75 (with CRMD 4. 0 image plates), Kodak CR 850 (with Kodak GP plates) and Kodak CR 850A (with Kodak GP plates) were evaluated using six tests recommended in American Association of Physicists in Medicine Report 93. The results indicated variable performances with majority being within acceptable limits. The variations were mainly attributed to differences in detector formulations, plate readers' characteristics, and aging effects. The differences of the mean low contrast scores between the imaging systems for three observers were statistically significant for Agfa and Kodak CR 850A (P=0.009) and for Kodak CR systems (P=0.006) probably because of the differences in ages. However, the differences were not statistically significant between Agfa and Kodak CR 850 (P=0.284) suggesting similar perceived image quality. The study demonstrates the need to implement quality control program regularly. (author)

  1. Cantilever biosensor reader using a common-path, holographic optical interferometer

    DEFF Research Database (Denmark)

    Pedersen, Henrik Chresten; Jakobsen, Michael Linde; Hanson, Steen Grüner

    2010-01-01

    We demonstrate an optical reader principle aimed at monitoring biologically induced deflections of microcantilevers often used in biosensor systems. The principle is based on a so-called common-path optical interferometer in which the two interfering optical beams are copropagating,which makes...

  2. Reader Engagement in English and Persian Applied Linguistics Articles

    Science.gov (United States)

    Ansarin, Ali Akbar; Tarlani-Aliabdi, Hassan

    2011-01-01

    There is an increasing interest in the way academic writers establish the presence of their readers over the past few years. Establishing the presence of readers or what Kroll (1984, p.181) calls imagining "a second voice" is accomplished when a writer refers "explicitly" to their readers using explicit linguistic resources…

  3. Modeling particulate removal in plate-plate and wire-plate electrostatic precipitators

    Directory of Open Access Journals (Sweden)

    S Ramechecandane

    2016-09-01

    Full Text Available The present study is concerned with the modeling of electrically charged particles in a model plate-plate and a single wire-plate electrostatic precipitator (ESP. The particle concentration distributions for both a plate-plate and a wire-plate ESP are calculated using a modified drift flux model. Numerical investigations are performed using the modified drift flux model for particle number concentration, in addition to the RNG k - ε model for the mean turbulent flow field and the Poisson equation for the electric field. The proposed model and the outlined methodology for coupling the flow field, electric field, charging kinetics and particle concentration is applied to two model precipitators that are truly representative of a wide class of commercialized ESPs. The present investigation is quite different from the earlier studies as it does not make assumptions like a homogeneous electric field or an infinite turbulent diffusivity. The electric field calculated is a strong function of position and controls the migration velocity of particles. Hence, the proposed model can be implemented in a flow solver to obtain a full-fledged solution for any kind of ESP with no limitations on the particle number concentration, as encountered in a Lagrangian approach. The effect of turbulent diffusivity on particle number concentration in a plate-plate ESP is investigated in detail and the results obtained are compared with available experimental data. Similarly, the effect of particle size/diameter and applied electric potential on the accumulative collection performance in the case of a wire-plate ESP is studied and the results obtained are compared with available numerical data. The numerical results obtained using the modified drift flux model for both the plate-plate and wire-plate ESP are in close agreement with available experimental and numerical data.

  4. Optimal Placement Method of RFID Readers in Industrial Rail Transport for Uneven Rail Traflc Volume Management

    Science.gov (United States)

    Rakhmangulov, Aleksandr; Muravev, Dmitri; Mishkurov, Pavel

    2016-11-01

    The issue of operative data reception on location and movement of railcars is significant the constantly growing requirements of the provision of timely and safe transportation. The technical solution for efficiency improvement of data collection on rail rolling stock is the implementation of an identification system. Nowadays, there are several such systems, distinguished in working principle. In the authors' opinion, the most promising for rail transportation is the RFID technology, proposing the equipping of the railway tracks by the stationary points of data reading (RFID readers) from the onboard sensors on the railcars. However, regardless of a specific type and manufacturer of these systems, their implementation is affiliated with the significant financing costs for large, industrial, rail transport systems, owning the extensive network of special railway tracks with a large number of stations and loading areas. To reduce the investment costs for creation, the identification system of rolling stock on the special railway tracks of industrial enterprises has developed the method based on the idea of priority installation of the RFID readers on railway hauls, where rail traffic volumes are uneven in structure and power, parameters of which is difficult or impossible to predict on the basis of existing data in an information system. To select the optimal locations of RFID readers, the mathematical model of the staged installation of such readers has developed depending on the non-uniformity value of rail traffic volumes, passing through the specific railway hauls. As a result of that approach, installation of the numerous RFID readers at all station tracks and loading areas of industrial railway stations might be not necessary,which reduces the total cost of the rolling stock identification and the implementation of the method for optimal management of transportation process.

  5. Lesion type and reader experience affect the diagnostic accuracy of breast MRI: A multiple reader ROC study

    Energy Technology Data Exchange (ETDEWEB)

    Baltzer, Pascal A.T., E-mail: patbaltzer@gmail.com [Department of Biomedical Imaging and Imge-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090 Vienna (Austria); Kaiser, Werner Alois [Department of Diagnostic and Interventional Radiology, University Hospital Jena, Erlanger Allee 101, 07740 Jena (Germany); Dietzel, Matthias, E-mail: dietzelmatthias2@hotmail.com [Department of Neuroradiology, University Hospital Erlangen, Schwabachanlage 6, 91054 Erlangen (Germany)

    2015-01-15

    Highlights: • The main findings of our study are, that reader experience and lesion type (i.e., mass versus non-mass enhancement) are independent predictors of the diagnostic accuracy of breast MRI. • Specifically, benign and malignant non-mass lesions cannot be differentiated with sufficient accuracy, especially if readers are not experienced. • We conclude that future research in breast MRI should focus on non-mass lesions, as these are the problem makers in modern breast MRI. - Abstract: Purpose: To evaluate the influence of lesion type (mass versus non-mass) and reader experience on the diagnostic performance of breast MRI (BMRI) in a non-screening setting. Materials and methods: Consecutive patients (mean age, 55 ± 12 years) with breast lesions that were verified by biopsy or surgery, and who had had BMRI as part of their diagnostic workup, were eligible for this retrospective single-center study. Cancers diagnosed by biopsy before BMRI were excluded to eliminate biological and interpretation bias due to biopsy or chemotherapy effects (n = 103). Six blinded readers (experience level, high (HE, n = 2); intermediate (IE, n = 2); and low (LE, n = 2)) evaluated all examinations and assigned independent MRI BI-RADS ratings. Lesion type (mass, non-mass, focal) was noted. Receiver operating characteristics (ROC) and logistic regression analysis was performed to compare diagnostic accuracies. Results: There were 259 histologically verified lesions (123 malignant, 136 benign) investigated. There were 169 mass (103 malignant, 66 benign) and 48 non-mass lesions (19 malignant, 29 benign). Another 42 lesions that met the inclusion criteria were biopsied due to conventional findings (i.e., microcalcifications, architectural distortions), but did not enhance on MRI (41 benign, one DCIS). ROC analysis revealed a total area under the curve (AUC) between 0.834 (LE) and 0.935 (HI). Logistic regression identified a significant effect of non-mass lesions (P < 0.0001) and

  6. Face-to-face with the reader

    Directory of Open Access Journals (Sweden)

    Tatiana KAIGORODOVA

    2016-03-01

    Full Text Available Thank you for inviting me to this meeting. I understood that it is a meeting of the editorial board with readers. But I would like to note that there is still such a small layer between the editors and readers, which is called the printing house. So it is the typography that materially embodies the ideas, thoughts and innovations of the editorial staff and the authors.

  7. Readers Theatre plus Comprehension and Word Study

    Science.gov (United States)

    Young, Chase; Stokes, Faida; Rasinski, Timothy

    2017-01-01

    Readers Theatre has been used to introduce critical issues, promote fluency among English learners and non-English learners, teach vocabulary, and integrate content in the classroom. Previous studies of Readers Theatre application have demonstrated an increase in student reading fluency, motivation, and confidence. The focus of this systemic…

  8. Low self-concept in poor readers: prevalence, heterogeneity, and risk.

    Science.gov (United States)

    McArthur, Genevieve; Castles, Anne; Kohnen, Saskia; Banales, Erin

    2016-01-01

    There is evidence that poor readers are at increased risk for various types of low self-concept-particularly academic self-concept. However, this evidence ignores the heterogeneous nature of poor readers, and hence the likelihood that not all poor readers have low self-concept. The aim of this study was to better understand which types of poor readers have low self-concept. We tested 77 children with poor reading for their age for four types of self-concept, four types of reading, three types of spoken language, and two types of attention. We found that poor readers with poor attention had low academic self-concept, while poor readers with poor spoken language had low general self-concept in addition to low academic self-concept. In contrast, poor readers with typical spoken language and attention did not have low self-concept of any type. We also discovered that academic self-concept was reliably associated with reading and receptive spoken vocabulary, and that general self-concept was reliably associated with spoken vocabulary. These outcomes suggest that poor readers with multiple impairments in reading, language, and attention are at higher risk for low academic and general self-concept, and hence need to be assessed for self-concept in clinical practice. Our results also highlight the need for further investigation into the heterogeneous nature of self-concept in poor readers.

  9. Low self-concept in poor readers: prevalence, heterogeneity, and risk

    Science.gov (United States)

    Castles, Anne; Kohnen, Saskia; Banales, Erin

    2016-01-01

    There is evidence that poor readers are at increased risk for various types of low self-concept—particularly academic self-concept. However, this evidence ignores the heterogeneous nature of poor readers, and hence the likelihood that not all poor readers have low self-concept. The aim of this study was to better understand which types of poor readers have low self-concept. We tested 77 children with poor reading for their age for four types of self-concept, four types of reading, three types of spoken language, and two types of attention. We found that poor readers with poor attention had low academic self-concept, while poor readers with poor spoken language had low general self-concept in addition to low academic self-concept. In contrast, poor readers with typical spoken language and attention did not have low self-concept of any type. We also discovered that academic self-concept was reliably associated with reading and receptive spoken vocabulary, and that general self-concept was reliably associated with spoken vocabulary. These outcomes suggest that poor readers with multiple impairments in reading, language, and attention are at higher risk for low academic and general self-concept, and hence need to be assessed for self-concept in clinical practice. Our results also highlight the need for further investigation into the heterogeneous nature of self-concept in poor readers. PMID:27867764

  10. Degradation behaviour of LAE442-based plate-screw-systems in an in vitro bone model.

    Science.gov (United States)

    Wolters, Leonie; Besdo, Silke; Angrisani, Nina; Wriggers, Peter; Hering, Britta; Seitz, Jan-Marten; Reifenrath, Janin

    2015-04-01

    The use of absorbable implant materials for fixation after bone fracture helps to avoid a second surgery for implant removal and the risks and costs involved. Magnesium (Mg) is well known as a potential metallic material for degradable implants. The aim of the present in vitro study was to evaluate if degradable LAE442-based magnesium plate-screw-systems are suitable candidates for osteosynthesis implants in load-bearing bones. The corrosion behaviour was tested concerning the influence of different surface treatments, coatings and screw torques. Steel plates and screws of the same size served as control. Plates without special treatment screwed on up to a specified torque of 15cNm or 7cNm, NaOH treated plates (15cNm), magnesium fluoride coated plates (15cNm) and steel plates as control (15cNm) were examined in pH-buffered, temperature-controlled SBF solution for two weeks. The experimental results indicate that the LAE442 plates and screws coated with magnesium fluoride revealed a lower hydrogen evolution in SBF solution as well as a lower weight loss and volume decrease in μ-computed tomography (μCT). The nanoindentation and SEM/EDX measurements at several plate areas showed no significant differences. Summarized, the different screw torques did not affect the corrosion behaviour differently. Also the NaOH treatment seemed to have no essential influence on the degradation kinetics. The plates coated with magnesium fluoride showed a decreased corrosion rate. Hence, it is recommended to consider this coating for the next in vivo study. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Proceedings of the Flat-Plate Solar Array Project Research Forum on Photovoltaic Metallization Systems

    Science.gov (United States)

    1983-01-01

    A photovoltaic Metallization Research forum, under the sponsorship of the Flat-Plate Solar Array Project consisted of five sessions, covering: (1) the current status of metallization systems, (2) system design, (3) thick-film metallization, (4) advanced techniques, and (5) future metallization challenges.

  12. The influence of reading expertise in mirror-letter perception: Evidence from beginning and expert readers

    Science.gov (United States)

    Duñabeitia, Jon Andoni; Dimitropoulou, María; Estévez, Adelina; Carreiras, Manuel

    2013-01-01

    The visual word recognition system recruits neuronal systems originally developed for object perception which are characterized by orientation insensitivity to mirror reversals. It has been proposed that during reading acquisition beginning readers have to “unlearn” this natural tolerance to mirror reversals in order to efficiently discriminate letters and words. Therefore, it is supposed that this unlearning process takes place in a gradual way and that reading expertise modulates mirror-letter discrimination. However, to date no supporting evidence for this has been obtained. We present data from an eye-movement study that investigated the degree of sensitivity to mirror-letters in a group of beginning readers and a group of expert readers. Participants had to decide which of the two strings presented on a screen corresponded to an auditorily presented word. Visual displays always included the correct target word and one distractor word. Results showed that those distractors that were the same as the target word except for the mirror lateralization of two internal letters attracted participants’ attention more than distractors created by replacement of two internal letters. Interestingly, the time course of the effects was found to be different for the two groups, with beginning readers showing a greater tolerance (decreased sensitivity) to mirror-letters than expert readers. Implications of these findings are discussed within the framework of preceding evidence showing how reading expertise modulates letter identification. PMID:24273596

  13. EMPIRICAL STUDY OF CAR LICENSE PLATES RECOGNITION

    Directory of Open Access Journals (Sweden)

    Nasa Zata Dina

    2015-01-01

    Full Text Available The number of vehicles on the road has increased drastically in recent years. The license plate is an identity card for a vehicle. It can map to the owner and further information about vehicle. License plate information is useful to help traffic management systems. For example, traffic management systems can check for vehicles moving at speeds not permitted by law and can also be installed in parking areas to se-cure the entrance or exit way for vehicles. License plate recognition algorithms have been proposed by many researchers. License plate recognition requires license plate detection, segmentation, and charac-ters recognition. The algorithm detects the position of a license plate and extracts the characters. Various license plate recognition algorithms have been implemented, and each algorithm has its strengths and weaknesses. In this research, I implement three algorithms for detecting license plates, three algorithms for segmenting license plates, and two algorithms for recognizing license plate characters. I evaluate each of these algorithms on the same two datasets, one from Greece and one from Thailand. For detecting li-cense plates, the best result is obtained by a Haar cascade algorithm. After the best result of license plate detection is obtained, for the segmentation part a Laplacian based method has the highest accuracy. Last, the license plate recognition experiment shows that a neural network has better accuracy than other algo-rithm. I summarize and analyze the overall performance of each method for comparison.

  14. CAD-CAM plates versus conventional fixation plates for primary mandibular reconstruction: A biomechanical in vitro analysis.

    Science.gov (United States)

    Rendenbach, Carsten; Sellenschloh, Kay; Gerbig, Lucca; Morlock, Michael M; Beck-Broichsitter, Benedicta; Smeets, Ralf; Heiland, Max; Huber, Gerd; Hanken, Henning

    2017-11-01

    CAD/CAM reconstruction plates have become a viable option for mandible reconstruction. The aim of this study was to determine whether CAD/CAM plates provide higher fatigue strength compared with conventional fixation systems. 1.0 mm miniplates, 2.0 mm conventional locking plates (DePuy Synthes, Umkirch, Germany), and 2.0 mm CAD/CAM plates (Materialise, Leuven, Belgium/DePuy Synthes) were used to reconstruct a polyurethane mandible model (Synbone, Malans, CH) with cortical and cancellous bone equivalents. Mastication was simulated via cyclic dynamic testing using a universal testing machine (MTS, Bionix, Eden Prairie, MN, USA) until material failure reached a rate of 1 Hz with increasing loads on the left side. No significant difference was found between the groups until a load of 300 N. At higher loads, vertical displacement differed increasingly, with a poorer performance of miniplates (p = 0.04). Plate breakage occurred in miniplates and conventional locking plates. Screw breakage was recorded as the primary failure mechanism in CAD/CAM plates. Stiffness was significantly higher with the CAD/CAM plates (p = 0.04). CAD/CAM plates and reconstruction plates provide higher fatigue strength than miniplates, and stiffness is highest in CAD/CAM systems. All tested fixation methods seem sufficiently stable for mandible reconstruction. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  15. Our Readers Write ...

    Indian Academy of Sciences (India)

    IAS Admin

    This concerns the article 'Ashoke Sen and S-duality'. The article omits an important fact: there is absolutely no experimental evidence for string theory. Without this information, readers may think they are reading about established facts, not speculation. A string theorist, Witten, was awarded a Fields Medal, which shows that ...

  16. Numerical investigation of coalescing plate system to understand the separation of water and oil in water treatment plant of petroleum industry

    Directory of Open Access Journals (Sweden)

    Sedat Yayla

    2017-01-01

    Full Text Available The most widely utilized process of produced water treatment is considered to be use of coalescing or corrugated plate systems in the oil industry because these systems have promising results in the acceleration of the separation process. Even use of corrugated plate systems seem to be effective in separation processes, the geometrical parameters of the plate system could greatly influence the performance of separation process. In this study, a two-dimensional computational fluid dynamics model for coalescing plates was developed to investigate Reynolds number and plate hole shape on separation efficiency. Spacing between plates was set to 12 mm while fluid mixture’s Reynolds number varied between 5 and 45 for the computational model. Hole profile and dimensions were determined to be cylindrical, rectangular and ellipse shapes as 10, 15 and 20 mm based on hydraulic diameter definition, respectively. Furthermore, when hole profiles of coalescing plates were chosen to be ellipse and rectangular shapes, separation efficiency nearly stayed constant regardless of hole dimension. The study also reported that change of oil fraction from 5% to 15% caused approximately 30% increase in the separation efficiency. The investigation also revealed Reynolds number of the mixture was inversely proportional to the separation efficiency. It was also found that the highest separation efficiency was obtained for a cylindrical shape with a hole diameter of 15 mm when distance between plates was 12 mm and Reynolds number was 18.

  17. Choosing the Adequate Level of Graded Readers--Preliminary Study

    Science.gov (United States)

    Prtljaga, Jelena; Palinkaševic, Radmila; Brkic, Jovana

    2015-01-01

    Graded readers have been used as second language teaching material since the end of the Second World War. They are an important source of simplified material which provides comprehensible input on all levels. It is of crucial importance for a successful usage of graded readers in the classroom and in studies which focus on graded readers, that an…

  18. Echoic memory processes in good and poor readers.

    Science.gov (United States)

    Sipe, S; Engle, R W

    1986-07-01

    Four experiments were conducted to determine whether echoic memory plays a role in differences between good and poor readers. The first two experiments used a suffix procedure in which the subject is read a list of digits with either a tone control or the word go appended to the list. For lists that exceeded the length of the subjects memory span by one digit (i.e., that avoided ceiling effects), the poor readers showed a larger decrement in the suffix condition than did the good readers. The third experiment was directed at the question of whether the duration of echoic memory is different for good and poor readers. Children shadowed words presented to one ear at a rate determined to give 75-85% shadowing accuracy. The items presented to the nonattended ear were words and an occasional digit. At various intervals after the presentation of the digit, a light signaled that the subject was to cease shadowing and attempt to recall any digit that had occurred in the nonattended ear recently. Whereas good and poor readers recalled the digit equally if tested immediately after presentation, the poor readers showed a faster decline in recall of the digit as retention interval increased. A fourth experiment was conducted to determine whether the differences in echoic memory were specific to speech stimuli or occurred at a more basic level of aural persistence. Bursts of white noise were separated by 9-400 ms of silence and the subject was to say whether there were one or two sounds presented. There were no differences in detectability functions for good and poor readers.

  19. Microplate-reader method for the rapid analysis of copper in natural waters with chemiluminescence detection

    Directory of Open Access Journals (Sweden)

    Axel eDurand

    2013-01-01

    Full Text Available We have developed a method for the determination of copper in natural waters at nanomolar levels. The use of a microplate-reader minimises sample processing time (~ 25 sec per sample, reagent consumption (~ 120 μL per sample and sample volume (~ 700 μL. Copper is detected by chemiluminescence. This technique is based on the formation of a complex between copper and 1,10-phenanthroline and the subsequent emission of light during the oxidation of the complex by hydrogen peroxide. Samples are acidified to pH 1.7 and then introduced directly into a 24-well plate. Reagents are added during data acquisition via two reagent injectors. When trace metal clean protocols are employed, the reproducibility is generally less then 7% on blanks and the detection limit is 0.7 nM for seawater and 0.4 nM for freshwater. More than 100 samples per hour can be analyzed with this technique, which is simple, robust, and amenable to at-sea analysis. Seawater samples from Storm Bay in Tasmania illustrate the utility of the method for environmental science. Indeed other trace metals for which optical detection methods exist (e.g. chemiluminescence, fluorescence and absorbance could be adapted to the microplate-reader.

  20. Visual Servoing Tracking Control of a Ball and Plate System: Design, Implementation and Experimental Validation

    Directory of Open Access Journals (Sweden)

    Ming-Tzu Ho

    2013-07-01

    Full Text Available This paper presents the design, implementation and validation of real-time visual servoing tracking control for a ball and plate system. The position of the ball is measured with a machine vision system. The image processing algorithms of the machine vision system are pipelined and implemented on a field programmable gate array (FPGA device to meet real-time constraints. A detailed dynamic model of the system is derived for the simulation study. By neglecting the high-order coupling terms, the ball and plate system model is simplified into two decoupled ball and beam systems, and an approximate input-output feedback linearization approach is then used to design the controller for trajectory tracking. The designed control law is implemented on a digital signal processor (DSP. The validity of the performance of the developed control system is investigated through simulation and experimental studies. Experimental results show that the designed system functions well with reasonable agreement with simulations.

  1. Practicum Training for Teachers of Struggling Readers

    Science.gov (United States)

    Morris, Darrell

    2011-01-01

    Teachers who work with struggling beginning readers need a supervised training experience that leads them to understand both how reading ability develops and how to adapt instruction to meet the needs of individual children. The practicum, in which a teacher works with one struggling reader under the supervision of an experienced and expert…

  2. Theroretical modelling of the plate-tubes coupling in the hydroelasticity of the perforated plates

    International Nuclear Information System (INIS)

    Dzhupanov, V.A.; Manoach, E.S.

    1983-01-01

    In the previous investigations on the perforated plate hydroelasticity the problem of the plates-tubes-liquid interaction in the process of the general structural vibration is stated. But the interaction of the vibrating plates with the tubes, passing through them, is taken into account considering the tubes only as absolutely rigid supports. This is one of the possible technical realizations. In the present article the case when the tubes are taking part in the plate motion (vibration) is studied. Two circular perforated plates are supported by the absolutely rigid wall of the modelled roundcircular reactor barrel. The distance between the plates is given. They are connected by tubes, passing through, and clamped into the perforation holes. The plates and the tubes are made by any elastic HOOKIAN material. The volume between the two plates and outwardly to the tubes, but intrinsically of the barrel is filled by ideal, compressible and heavy liquid. Evidently the liquid volume is multiconnected one. The free vibration of the whole system is considered with the purposes: i) to give a theoretical model of the plates-tubes-liquid interaction including governing equations and boundary conditions; ii) to trace the solution of the eigen-value problem for the modelled structure; iii) to underline the engineering sides of the modelling process. (orig./GL)

  3. Sensor network based vehicle classification and license plate identification system

    Energy Technology Data Exchange (ETDEWEB)

    Frigo, Janette Rose [Los Alamos National Laboratory; Brennan, Sean M [Los Alamos National Laboratory; Rosten, Edward J [Los Alamos National Laboratory; Raby, Eric Y [Los Alamos National Laboratory; Kulathumani, Vinod K [WEST VIRGINIA UNIV.

    2009-01-01

    Typically, for energy efficiency and scalability purposes, sensor networks have been used in the context of environmental and traffic monitoring applications in which operations at the sensor level are not computationally intensive. But increasingly, sensor network applications require data and compute intensive sensors such video cameras and microphones. In this paper, we describe the design and implementation of two such systems: a vehicle classifier based on acoustic signals and a license plate identification system using a camera. The systems are implemented in an energy-efficient manner to the extent possible using commercially available hardware, the Mica motes and the Stargate platform. Our experience in designing these systems leads us to consider an alternate more flexible, modular, low-power mote architecture that uses a combination of FPGAs, specialized embedded processing units and sensor data acquisition systems.

  4. Examining College Students’ Reading Behaviors and Needs for Ebook Readers

    Directory of Open Access Journals (Sweden)

    Wei-Jane Lin

    2012-12-01

    Full Text Available This study investigates college students’ reading behaviors and attitudes toward print and electronic carriers of books. With the prosperity and variety of ebook readers currently, it is important to understand the genuine needs of the users to better leverage the features and functions of the ebook readers. The methodology of survey research is conducted to explore 76 undergraduate students’ experiences, preferences and appraisals toward reading via the print books and ebook readers. Generally the college students possess positive attitudes toward and are willing to take advantage of the ebook and ebook reader services provided by libraries, but the current rate of use is low. The results suggested that student adoption of ebook readers are affected by their goals of reading. The college students prefer ebook readers significantly for leisure reading, and highly demand the functionality of multimedia presentations and file management. When reading academic contexts, the college students preferred hardcovers and online ebooks via the Web browser, and they value the functions of searching, marking and file management on ebook readers especially. [Article content in Chinese

  5. Skilled deaf readers have an enhanced perceptual span in reading.

    Science.gov (United States)

    Bélanger, Nathalie N; Slattery, Timothy J; Mayberry, Rachel I; Rayner, Keith

    2012-07-01

    Recent evidence suggests that, compared with hearing people, deaf people have enhanced visual attention to simple stimuli viewed in the parafovea and periphery. Although a large part of reading involves processing the fixated words in foveal vision, readers also utilize information in parafoveal vision to preprocess upcoming words and decide where to look next. In the study reported here, we investigated whether auditory deprivation affects low-level visual processing during reading by comparing the perceptual span of deaf signers who were skilled and less-skilled readers with the perceptual span of skilled hearing readers. Compared with hearing readers, the two groups of deaf readers had a larger perceptual span than would be expected given their reading ability. These results provide the first evidence that deaf readers' enhanced attentional allocation to the parafovea is used during complex cognitive tasks, such as reading.

  6. Readers and Texts in the Primary Years. Rethinking Reading.

    Science.gov (United States)

    Martin, Tony; Leather, Bob

    Exploring the responses of a variety of readers from three-year-old Dominic sharing a picture book with his father to adults reading a poem by Ted Hughes, this book examines the ways in which various readers respond to different texts. The aim of the book is to develop an awareness of the issues involved in readers' responses for primary teachers.…

  7. Teaching the Total Language with Readers Theatre.

    Science.gov (United States)

    Goodman, Jess A., Jr.

    Reading, writing, speech assignments for special education classes, English as a second language and many other classroom projects can be taught through the involvement created by Readers Theatre. Readers Theatre is the presentation of dialogue-type material in play form. The actors hold the script as they move through it and a narrator's voice…

  8. Comparison of Thermal Performances between Low Porosity Perforate Plate and Flat Plate Solar Air Collector

    Science.gov (United States)

    Chan, Hoy-Yen; Vinson, A. A.; Baljit, S. S. S.; Ruslan, M. H.

    2018-04-01

    Flat plate solar air collector is the most common collector design, which is relatively simpler to fabricate and lower cost. In the present study, perforated plate solar collector was developed to improve the system thermal performance. A glazed perforated plate of 6mm holes diameter with square geometry was designed and installed as the absorber of the collector. The influences of solar radiation intensity and mass flow rate on the thermal performance were investigated. The perforated collector was compared with the flat plate solar collector under the same operating conditions. The highest values of thermal efficiency in this study for the perforated plate (PP) and the flat plate (FP) solar collectors were 59% and 36% respectively, at solar radiation intensity of 846 Wm-2 and mass flow rate of 0.02 kgs-1. Furthermore, PP collector gave better thermal performance compared to FP collector; and compared to previous studies, the present perforated design was compatible with the flat plate with double pass designs.

  9. Journal of Clipped Words in Reader's Digest Magazine

    OpenAIRE

    Simanjuntak, Lestari

    2012-01-01

    This study deals with Clipped Words in the “Laughter, the Best Medicine” of Reader's Digest. The objectives of the study are to find out the types of clipped words which are used in the “Laughter, the Best Medicine” of Reader's Digest, to find out sthe dominantly used in the whole story and to reason the dominant clipped word use in the text. The study use descriptive qualitative method. The data were collected from seventeen selected Reader's Digest which contains the clipped word by applie...

  10. System Advisor Model: Flat Plate Photovoltaic Performance Modeling Validation Report

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, Janine [National Renewable Energy Lab. (NREL), Golden, CO (United States); Whitmore, Jonathan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Kaffine, Leah [National Renewable Energy Lab. (NREL), Golden, CO (United States); Blair, Nate [National Renewable Energy Lab. (NREL), Golden, CO (United States); Dobos, Aron P. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2013-12-01

    The System Advisor Model (SAM) is a free software tool that performs detailed analysis of both system performance and system financing for a variety of renewable energy technologies. This report provides detailed validation of the SAM flat plate photovoltaic performance model by comparing SAM-modeled PV system generation data to actual measured production data for nine PV systems ranging from 75 kW to greater than 25 MW in size. The results show strong agreement between SAM predictions and field data, with annualized prediction error below 3% for all fixed tilt cases and below 8% for all one axis tracked cases. The analysis concludes that snow cover and system outages are the primary sources of disagreement, and other deviations resulting from seasonal biases in the irradiation models and one axis tracking issues are discussed in detail.

  11. Maskless, parallel patterning with zone-plate array lithography

    International Nuclear Information System (INIS)

    Carter, D. J. D.; Gil, Dario; Menon, Rajesh; Mondol, Mark K.; Smith, Henry I.; Anderson, Erik H.

    1999-01-01

    Zone-plate array lithography (ZPAL) is a maskless lithography scheme that uses an array of shuttered zone plates to print arbitrary patterns on a substrate. An experimental ultraviolet ZPAL system has been constructed and used to simultaneously expose nine different patterns with a 3x3 array of zone plates in a quasidot-matrix fashion. We present exposed patterns, describe the system design and construction, and discuss issues essential to a functional ZPAL system. We also discuss another ZPAL system which operates with 4.5 nm x radiation from a point source. We present simulations which show that, with our existing x-ray zone plates and this system, we should be able to achieve 55 nm resolution. (c) 1999 American Vacuum Society

  12. Evaluation of the light scattering and the turbidity microtiter plate-based methods for the detection of the excipient-mediated drug precipitation inhibition.

    Science.gov (United States)

    Petruševska, Marija; Urleb, Uroš; Peternel, Luka

    2013-11-01

    The excipient-mediated precipitation inhibition is classically determined by the quantification of the dissolved compound in the solution. In this study, two alternative approaches were evaluated, one is the light scattering (nephelometer) and other is the turbidity (plate reader) microtiter plate-based methods which are based on the quantification of the compound precipitate. Following the optimization of the nephelometer settings (beam focus, laser gain) and the experimental conditions, the screening of 23 excipients on the precipitation inhibition of poorly soluble fenofibrate and dipyridamole was performed. The light scattering method resulted in excellent correlation (r>0.91) between the calculated precipitation inhibitor parameters (PIPs) and the precipitation inhibition index (PI(classical)) obtained by the classical approach for fenofibrate and dipyridamole. Among the evaluated PIPs AUC100 (nephelometer) resulted in only four false positives and lack of false negatives. In the case of the turbidity-based method a good correlation of the PI(classical) was obtained for the PIP maximal optical density (OD(max), r=0.91), however, only for fenofibrate. In the case of the OD(max) (plate reader) five false positives and two false negatives were identified. In conclusion, the light scattering-based method outperformed the turbidity-based one and could be reliably used for identification of novel precipitation inhibitors. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. A multichannel deflection plates control system for the ALF facility at the APS

    International Nuclear Information System (INIS)

    Deriy, B.

    2006-01-01

    A deflection plates control system was developed as part of SPIRIT (Single Photon Ionization/Resonant Ionization to Threshold), a new secondary neutral mass spectrometry (SNMS) instrument that uses tunable vacuum ultraviolet light from the APS ALF (Argonne Linear Free-electron laser) facility for postionization. The system comprises a crate controller with PC104 embedded computer, 32 amplifiers, and two 1-kV power supplies. Thirty-two D/A converters are used to control voltages at the deflection plates within ± 400 V with 100-mV resolution. An algorithm for simultaneous sweeping of up to 16 XY areas with 10-(micro)s time resolution also has been implemented in the embedded computer. The purpose of the system is to supply potentials to various ion optical elements for electrostatic control of keV primary and secondary ion beams in this SNMS instrument. The control system is of particular value in supplying (1) bipolar potentials for steering ions, (2) multiple potentials for octupole lenses that shape the ion beams, and (3) ramped deflection potentials for rastering the primary ion beam. The system has been in use as part of the SPIRIT instrument at the ALF facility since 2002.

  14. Environmental dose measurement with microprocessor based portable TLD reader

    International Nuclear Information System (INIS)

    Deme, S.; Apathy, I.; Feher, I.

    1996-01-01

    Application of TL method for environmental gamma-radiation dosimetry involves uncertainty caused by the dose collected during the transport from the point of annealing to the place of exposure and back to the place of evaluation. Should an accident occur read out is delayed due to the need to transport to a laboratory equipped with a TLD reader. A portable reader capable of reading out the TL dosemeter at the place of exposure ('in situ TLD reader') eliminates the above mentioned disadvantages. We have developed a microprocessor based portable TLD reader for monitoring environmental gamma-radiation doses and for on board reading out of doses on space stations. The first version of our portable, battery operated reader (named Pille - 'butterfly') was made at the beginning of the 80s. These devices used CaSO 4 bulb dosemeters and the evaluation technique was based on analogue timing circuits and analogue to digital conversion of the photomultiplier current with a read out precision of 1 μGy and a measuring range up to 10 Gy. The measured values were displayed and manually recorded. The version with an external power supply was used for space dosimetry as an onboard TLD reader

  15. Sexism Springs Eternal--in the Reader's Digest.

    Science.gov (United States)

    Zimbardo, Philip G.; Meadow, Wendy

    This document reports on an empirical investigation of anti-women humor appearing in the Reader's Digest over three decades, revealing the operation of an unconscious sexist ideology. A systematic analysis was made of 1,069 jokes appearing in two featured columns of the Reader's Digest for the two-year periods 1947-48, 1957-58, and 1967-68.…

  16. Planning Behaviour in Good and Poor Readers

    Science.gov (United States)

    Mahapatra, Shamita

    2016-01-01

    A group of 50 good readers and a group of 50 poor readers of Grade 5 matched for age and intelligence and selected on the basis of their proficiency in reading comprehension were tested for their competence in word reading and the process of planning at three different levels, namely, perceptual, memory and conceptual in order to study the…

  17. Embedded adhesive connection for laminated glass plates

    DEFF Research Database (Denmark)

    Hansen, Jens Zangenberg; Poulsen, S.H.; Bagger, A.

    2012-01-01

    The structural behavior of a new connection design, the embedded adhesive connection, used for laminated glass plates is investigated. The connection consists of an aluminum plate encapsulated in-between two adjacent triple layered laminated glass plates. Fastening between glass and aluminum...... usage in a design situation. The embedded connection shows promising potential as a future fastening system for load-carrying laminated glass plates....

  18. How Do Fluent and Poor Readers' Endurance Differ in Reading?

    Science.gov (United States)

    Bastug, Muhammet; Keskin, Hasan Kagan; Akyol, Mustafa

    2017-01-01

    It was observed in this research how endurance status of fluent readers and poor readers changed as the text became longer. 40 students of the primary school 4th-grade, 20 were fluent readers and other 20 were poor readers, participated in the research. A narrative text was utilised in the data collection process. Students' oral readings were…

  19. Fabricating cooled electronic system with liquid-cooled cold plate and thermal spreader

    Science.gov (United States)

    Chainer, Timothy J.; Graybill, David P.; Iyengar, Madhusudan K.; Kamath, Vinod; Kochuparambil, Bejoy J.; Schmidt, Roger R.; Steinke, Mark E.

    2018-03-27

    Methods are provided for facilitating cooling of an electronic component. The method includes providing a liquid-cooled cold plate and a thermal spreader associated with the cold plate. The cold plate includes multiple coolant-carrying channel sections extending within the cold plate, and a thermal conduction surface with a larger surface area than a surface area of the component to be cooled. The thermal spreader includes one or more heat pipes including multiple heat pipe sections. One or more heat pipe sections are partially aligned to a first region of the cold plate, that is, where aligned to the surface to be cooled, and partially aligned to a second region of the cold plate, which is outside the first region. The one or more heat pipes facilitate distribution of heat from the electronic component to coolant-carrying channel sections of the cold plate located in the second region of the cold plate.

  20. Fabricating cooled electronic system with liquid-cooled cold plate and thermal spreader

    Energy Technology Data Exchange (ETDEWEB)

    Chainer, Timothy J.; Graybill, David P.; Iyengar, Madhusudan K.; Kamath, Vinod; Kochuparambil, Bejoy J.; Schmidt, Roger R.; Steinke, Mark E.

    2018-04-03

    Methods are provided for facilitating cooling of an electronic component. The methods include providing a liquid-cooled cold plate and a thermal spreader associated with the cold plate. The cold plate includes multiple coolant-carrying channel sections extending within the cold plate, and a thermal conduction surface with a larger surface area than a surface area of the component to be cooled. The thermal spreader includes one or more heat pipes including multiple heat pipe sections. One or more heat pipe sections are partially aligned to a first region of the cold plate, that is, where aligned to the surface to be cooled, and partially aligned to a second region of the cold plate, which is outside the first region. The one or more heat pipes facilitate distribution of heat from the electronic component to coolant-carrying channel sections of the cold plate located in the second region of the cold plate.

  1. Hydrodynamics of a flexible plate between pitching rigid plates

    Science.gov (United States)

    Kim, Junyoung; Kim, Daegyoum

    2017-11-01

    The dynamics of a flexible plate have been studied as a model problem in swimming and flying of animals and fluid-structure interaction of plants and flags. Motivated by fish schooling and an array of sea grasses, we investigate the dynamics of a flexible plate closely placed between two pitching rigid plates. In most studies on passive deformation of the flexible plate, the plate is immersed in a uniform flow or a wavy flow. However, in this study, the flexible plate experiences periodic deformation by the oscillatory flow generated by the prescribed pitching motion of the rigid plates. In our model, the pitching axes of the rigid plates and the clamping position of the flexible plate are aligned on the same line. The flexible plate shows various responses depending on length and pitching frequency of rigid plates, thickness of a flexible plate, and free-stream velocity. To find the effect of each variable on the response of the flexible plate, amplitude of a trailing edge and modal contribution of a flapping motion are compared, and flow structure around the flexible plate is examined.

  2. PorTL - a compact, portable TLD reader for environmental and personal dosimetry

    International Nuclear Information System (INIS)

    Deme, S.; Apathy, I.; Bodnar, L.; Csoke, A.; Feher, I.; Pazmandi, T.

    2005-01-01

    Thermoluminescent dosimeters (TLDs) are commonly used for environmental monitoring, for personal and medical dosimetry, for dosimetry in nuclear facilities, etc. Major advantages are their independence of the power supply, small dimension, sensitivity, good stability, wide measuring range, resistance to environmental changes and relatively low cost. The disadvantage is that the detector must be transported for evaluation to a laboratory equipped with a large, heavy and expensive TLD Reader operated by qualified personnel, which considerably increases the costs and delays results. To overcome this disadvantage, the KFKI Atomic Energy Research Institute (KFKI AEKI), in co-operation with BL Electronics (Hungary), has developed a new and unique TLD system containing a small, portable, battery powered and moderate-price reader for commercial use. This paper gives a detailed description and parameters of this system.(author)

  3. Glycan Reader: Automated Sugar Identification and Simulation Preparation for Carbohydrates and Glycoproteins

    Science.gov (United States)

    Jo, Sunhwan; Song, Kevin C.; Desaire, Heather; MacKerell, Alexander D.; Im, Wonpil

    2011-01-01

    Understanding how glycosylation affects protein structure, dynamics, and function is an emerging and challenging problem in biology. As a first step toward glycan modeling in the context of structural glycobiology, we have developed Glycan Reader and integrated it into the CHARMM-GUI, http://www.charmm-gui.org/input/glycan. Glycan Reader greatly simplifies the reading of PDB structure files containing glycans through (i) detection of carbohydrate molecules, (ii) automatic annotation of carbohydrates based on their three-dimensional structures, (iii) recognition of glycosidic linkages between carbohydrates as well as N-/O-glycosidic linkages to proteins, and (iv) generation of inputs for the biomolecular simulation program CHARMM with the proper glycosidic linkage setup. In addition, Glycan Reader is linked to other functional modules in CHARMM-GUI, allowing users to easily generate carbohydrate or glycoprotein molecular simulation systems in solution or membrane environments and visualize the electrostatic potential on glycoprotein surfaces. These tools are useful for studying the impact of glycosylation on protein structure and dynamics. PMID:21815173

  4. Reception theory and the Christian reader: A preliminary perspective

    Directory of Open Access Journals (Sweden)

    A. L. Comhrink

    1983-03-01

    Full Text Available In recent years there has been a significant shift in emphasis from text- centred criticism in literature to reader-centred criticism. This new field of criticism, called Reception Theory or Reader Response Criticism, denies the immutable nature of the "text” and regards as its object of study the work of literature that is created through the co-constituent creative and interpre­tive acts o f both writer and reader.

  5. Readers Theatre : Dramatising environment issues for oral skills development

    OpenAIRE

    Paatrick Ng Chin Leong

    2009-01-01

    Readers Theatre was introduced to a class of Japanese students studying intermediate-level English in an international university in Japan. The aim of the study is to investingate whether Readers Theatre enhances the oral skills of Japanese students as they negotiate an environmental issue in English. In my presentation, I will demonstrate how Readers Theatre is implemented in class and the comments by students will be analysed and discussed during the presentation.

  6. The suitability of gray-scale electronic readers for dermatology journals.

    Science.gov (United States)

    Choi, Jae Eun; Kim, Dai Hyun; Seo, Soo Hong; Kye, Young Chul; Ahn, Hyo Hyun

    2014-12-01

    The rapid development of information and communication technology has replaced traditional books by electronic versions. Most print dermatology journals have been replaced with electronic journals (e-journals), which are readily used by clinicians and medical students. The objectives of this study were to determine whether e-readers are appropriate for reading dermatology journals, to conduct an attitude study of both medical personnel and students, and to find a way of improving e-book use in the field of dermatology. All articles in the Korean Journal of Dermatology published from January 2010 to December 2010 were utilized in this study. Dermatology house officers, student trainees in their fourth year of medical school, and interns at Korea University Medical Center participated in the study. After reading the articles with Kindle 2, their impressions and evaluations were recorded using a questionnaire with a 5-point Likert scale. The results demonstrated that gray-scale e-readers might not be suitable for reading dermatology journals, especially for case reports compared to the original articles. Only three of the thirty-one respondents preferred e-readers to printed papers. The most common suggestions from respondents to encourage usage of e-books in the field of dermatology were the introduction of a color display, followed by the use of a touch screen system, a cheaper price, and ready-to-print capabilities. In conclusion, our study demonstrated that current e-readers might not be suitable for reading dermatology journals. However, they may be utilized in selected situations according to the type and topic of the papers.

  7. Visual consequences of electronic reader use: a pilot study.

    Science.gov (United States)

    Maducdoc, Marlon M; Haider, Asghar; Nalbandian, Angèle; Youm, Julie H; Morgan, Payam V; Crow, Robert W

    2017-04-01

    With the increasing prevalence of electronic readers (e-readers) for vocational and professional uses, it is important to discover if there are visual consequences in the use of these products. There are no studies in the literature quantifying the incidence or severity of eyestrain, nor are there clinical characteristics that may predispose to these symptoms with e-reader use. The primary objective of this pilot study was to assess the degree of eyestrain associated with e-reader use compared to traditional paper format. The secondary outcomes of this study were to assess the rate of eyestrain associated with e-reader use and identify any clinical characteristics that may be associated with the development of eyestrain. Forty-four students were randomly assigned to study (e-reader iPAD) and control (print) groups. Participant posture, luminosity of the room, and reading distance from reading device were measured during a 1-h session for both groups. At the end of the session, questionnaires were administered to determine symptoms. Significantly higher rates of eyestrain (p = 0.008) and irritation (p = 0.011) were found among the iPAD study group as compared to the print 'control' group. The study group was also 4.9 times more likely to report severe eyestrain (95 % CI [1.4, 16.9]). No clinical characteristics predisposing to eyestrain could be identified. These findings conclude that reading on e-readers may induce increased levels of irritation and eyestrain. Predisposing factors, etiology, and potential remedial interventions remain to be determined.

  8. Application of an imaging plate system to in vivo thyroid 131I monitoring

    International Nuclear Information System (INIS)

    Hirota, M.; Saze, T.; Nishizawa, K.

    2002-01-01

    An imaging plate (IP) system was applied to in vivo thyroid radioactive iodine 131 ( 131 I) monitoring. Thyroid contamination by 131 I occurs when medical staffs and patient's families take in 131 I used as treatment agent for thyroid cancer and hyperthyroidism in nuclear medicine, inhabitants take in 131 I released into environment by an accident of nuclear facilities, or worker take in 131 I used by experiment of research. The IP system is a two-dimensional integrating radiation detector which is a plate thinly coated plastic sheet with a kind of phosphore. The IP was exposed to a neck-thyroid phantom loaded 131 I aqueous solution. The IP system displayed a thyroid image that reflects a unique shape characteristic of the thyroid gland. A 131 I thyroid imaging allows visual confirmation of thyroid contamination by 131 I. The counting efficiency was approximately constant when neck diameter, thyroid volume and prethyroid tissue thickness varied within the normal adult. The detection limit of 450Bq was about 1/65 of the screening level of 30kBq. The IP system is applicable for thyroid 131 I monitoring

  9. Reading and Spelling Error Analysis of Native Arabic Dyslexic Readers

    Science.gov (United States)

    Abu-rabia, Salim; Taha, Haitham

    2004-01-01

    This study was an investigation of reading and spelling errors of dyslexic Arabic readers ("n"=20) compared with two groups of normal readers: a young readers group, matched with the dyslexics by reading level ("n"=20) and an age-matched group ("n"=20). They were tested on reading and spelling of texts, isolated…

  10. Evidence for deficits in the temporal attention span of poor readers.

    Directory of Open Access Journals (Sweden)

    Troy A W Visser

    Full Text Available While poor reading is often associated with phonological deficits, many studies suggest that visual processing might also be impaired. In particular, recent research has indicated that poor readers show impaired spatial visual attention spans in partial and whole report tasks. Given the similarities between competition-based accounts for reduced visual attention span and similar explanations for impairments in sequential object processing, the present work examined whether poor readers show deficits in their "temporal attention span"--that is, their ability to rapidly and accurately process sequences of consecutive target items.Poor and normal readers monitored a sequential stream of visual items for two (TT condition or three (TTT condition consecutive target digits. Target identification was examined using both unconditional and conditional measures of accuracy in order to gauge the overall likelihood of identifying a target and the likelihood of identifying a target given successful identification of previous items. Compared to normal readers, poor readers showed small but consistent deficits in identification across targets whether unconditional or conditional accuracy was used. Additionally, in the TTT condition, final-target conditional accuracy was poorer than unconditional accuracy, particularly for poor readers, suggesting a substantial cost arising from processing the previous two targets that was not present in normal readers.Mirroring the differences found between poor and normal readers in spatial visual attention span, the present findings suggest two principal differences between the temporal attention spans of poor and normal readers. First, the consistent pattern of reduced performance across targets suggests increased competition amongst items within the same span for poor readers. Second, the steeper decline in final target performance amongst poor readers in the TTT condition suggests a reduction in the extent of their

  11. Evidence for deficits in the temporal attention span of poor readers.

    Science.gov (United States)

    Visser, Troy A W

    2014-01-01

    While poor reading is often associated with phonological deficits, many studies suggest that visual processing might also be impaired. In particular, recent research has indicated that poor readers show impaired spatial visual attention spans in partial and whole report tasks. Given the similarities between competition-based accounts for reduced visual attention span and similar explanations for impairments in sequential object processing, the present work examined whether poor readers show deficits in their "temporal attention span"--that is, their ability to rapidly and accurately process sequences of consecutive target items. Poor and normal readers monitored a sequential stream of visual items for two (TT condition) or three (TTT condition) consecutive target digits. Target identification was examined using both unconditional and conditional measures of accuracy in order to gauge the overall likelihood of identifying a target and the likelihood of identifying a target given successful identification of previous items. Compared to normal readers, poor readers showed small but consistent deficits in identification across targets whether unconditional or conditional accuracy was used. Additionally, in the TTT condition, final-target conditional accuracy was poorer than unconditional accuracy, particularly for poor readers, suggesting a substantial cost arising from processing the previous two targets that was not present in normal readers. Mirroring the differences found between poor and normal readers in spatial visual attention span, the present findings suggest two principal differences between the temporal attention spans of poor and normal readers. First, the consistent pattern of reduced performance across targets suggests increased competition amongst items within the same span for poor readers. Second, the steeper decline in final target performance amongst poor readers in the TTT condition suggests a reduction in the extent of their temporal attention

  12. Empirical Study of Car License Plates Recognition

    OpenAIRE

    Dina, Nasa Zata; Dailey, Matthew

    2015-01-01

    The number of vehicles on the road has increased drastically in recent years. The license plate is an identity card for a vehicle. It can map to the owner and further information about vehicle. License plate information is useful to help traffic management systems. For example, traffic management systems can check for vehicles moving at speeds not permitted by law and can also be installed in parking areas to se-cure the entrance or exit way for vehicles. License plate recognition algorithms ...

  13. Gifted Male Readers: Current Understandings and Suggestions for Future Research

    Science.gov (United States)

    Pagnani, Alexander R.

    2013-01-01

    Research literature concerning gifted male readers relies primarily on more extensive bodies of work regarding gifted males and male readers. Studied as a whole, the two halves portray a worrisome state of affairs for gifted male readers, who lag behind their female counterparts in the same patterns found across the ability spectrum. This literacy…

  14. Rereading Multicultural Readers: What Definition of Multicultural Are We Buying?

    Science.gov (United States)

    Shapiro, Nancy

    A flood of new multicultural readers and textbooks are hitting the market for writing and literature courses at the college level. Yet there has been no systematic examination of how these readers are being used, the purposes and audiences for which they are written, or the critical reception they have received. Multicultural readers distinguish…

  15. LICENSE PLATE LOCALIZATION USING GABOR FILTERS AND NEURAL NETWORKS

    OpenAIRE

    Sami Ktata; Faouzi Benzarti; Hamid Amiri

    2013-01-01

    Vehicle License Plate Detection (LPD) is an important step for the vehicle plate recognition which can be used in the intelligent transport systems. Many methods have been proposed for the detection of license plates based on: Mathematical morphology, Discrete Wavelet Transform, Hough Transform and others. In general, an LPR system includes four main parts: Vehicle image acquisition, license plate detection, character segmentation and character recognition. In this study, we present a robust ...

  16. Reader construction in interactive online journalism

    DEFF Research Database (Denmark)

    Hartley, Jannie Møller

    how online journalists are constructing their readers, seeking to explain how these views affect practices of journalism. Gans idea of the “constructed public” is re-visited, by analyzing the newsroom negotiations between one hand enabling the user participation and on the other hand their very...... be seen as journalistic positioning strategies and interactivity and mediated connectivity as both vital and challenging for the very field of journalism. This indicates that not only do the different kinds of interactivity seem to imply different kind of readers – they also seem to imply different ideals...

  17. New IoT proximity service based heterogeneous RFID readers collision control

    Directory of Open Access Journals (Sweden)

    Jose Ignacio Tamayo Segarra

    2017-08-01

    Full Text Available Purpose – Internet of Things’ (IoT’s first wave started with tracking services for better inventory management mainly using radio frequency identification (RFID technology. Later on, monitoring services became one of the major interests, including sensing technologies, and then more actuation for remote control-type of IoT applications such as smart homes, smart cities and Industry 4.0. In this paper, the authors focus on the RFID technology impairment. They propose to take advantage of the mature IoT technologies that offer native service discovery such as blutooth or LTE D2D ProSe or Wifi Direct. Using the automatic service discovery in the new framework will make heterogeneous readers aware of the presence of other readers and this will be used by the proposed distributed algorithm to better control the multiple RFID reader interference problem. The author clearly considers emerging Industry 4.0 use case, where RFID technology is of major interest for both identification and tracking. To enhance the RFID tag reading performance, collisions in the RFID frequency should be minimized with reader-to-reader coordination protocols. In this paper, the author proposes a simple distributed reader anti-collision protocol named DiSim that makes use of proximity services of IoT network and is compliant with the current RFID standards. The author evaluates the efficiency of the proposal via simulation. Design/methodology/approach – In this paper, the author proposes a simple distributed reader anti-collision protocol named DiSim that makes use of proximity services of IoT network and is compliant with the current RFID standards. The author evaluates the efficiency of the proposal via simulation to study its behavior in very dense and heterogeneous RFID environments. Specifically, the author explores the coexistence of powerful static readers and small mobile readers, comparing the proposal with a standard ETSI CSMA method. The proposal reduces

  18. Pre-Stressing Timber-Based Plate Tensegrity Structures

    DEFF Research Database (Denmark)

    Falk, Andreas; Kirkegaard, Poul Henning

    2012-01-01

    Tensile structures occur in numerous varieties utilising combinations of tension and compression. Introducing structural plates in the basic tensegrity unit and tensegric assemblies varies the range of feasible topologies and provides the structural system with an integrated surface. The present...... paper considers the concept of plate tensegrity based on CLT plates (cross-laminated timber). It combines the principles of tensegrity with the principles of plate shells and is characterised by a plate shell stabilised by struts and cables. The paper deals with material aspects and robustness of timber...

  19. Using Randomized Clinical Trials to Determine the Impact of Reading Intervention on Struggling Adolescent Readers: Reports of Research from Five Nationally Funded Striving Readers Grants

    Science.gov (United States)

    Loadman, William; Sprague, Kim; Hamilton, Jennifer; Coffey, Deb; Faddis, Bonnie

    2010-01-01

    In 2005, the U.S. Department of Education awarded eight Striving Readers grants to projects around the country. The goal of Striving Readers is to improve literacy skills and achievement for struggling readers in middle and high school and to increase the research base using randomized clinical research to address improvement in adolescent…

  20. Separation method of heavy-ion particle image from gamma-ray mixed images using an imaging plate

    CERN Document Server

    Yamadera, A; Ohuchi, H; Nakamura, T; Fukumura, A

    1999-01-01

    We have developed a separation method of alpha-ray and gamma-ray images using the imaging plate (IP). The IP from which the first image was read out by an image reader was annealed at 50 deg. C for 2 h in a drying oven and the second image was read out by the image reader. It was found out that an annealing ratio, k, which is defined as a ratio of the photo-stimulated luminescence (PSL) density at the first measurement to that at the second measurement, was different for alpha rays and gamma rays. By subtracting the second image multiplied by a factor of k from the first image, the alpha-ray image was separated from the alpha and gamma-ray mixed images. This method was applied to identify the images of helium, carbon and neon particles of high energies using the heavy-ion medical accelerator, HIMAC. (author)

  1. A Comparative Review of Stratification Texts and Readers

    Science.gov (United States)

    Peoples, Clayton D.

    2012-01-01

    Social stratification is a core substantive area within sociology. There are a number of textbooks and readers available on the market that deal with this central topic. In this article, I conduct a comparative review of (a) four stratification textbooks and (b) four stratification readers. (Contains 2 tables.)

  2. Bytes, Books and Readers

    DEFF Research Database (Denmark)

    Rasmussen, Krista Stinne Greve

    2016-01-01

    In diesem Beitrag werden Ergebnisse aus der Dissertation der Autorin Bytes, Books, and Readers. A Historical Analysis of the Transition from Printed to Digital Scholarly Editions Focusing on ‘The Writings of Søren Kierkegaard’ (2015) vorgestellt. Dabei wird dem Wechselverhältnis zwischen der...

  3. Evaluation of Rapid Stain IDentification (RSID™ Reader System for Analysis and Documentation of RSID™ Tests

    Directory of Open Access Journals (Sweden)

    Pravatchai W. Boonlayangoor

    2013-08-01

    Full Text Available The ability to detect the presence of body fluids is a crucial first step in documenting and processing forensic evidence. The Rapid Stain IDentification (RSID™ tests for blood, saliva, semen and urine are lateral flow immunochromatographic strip tests specifically designed for forensic use. Like most lateral flow strips, the membrane components of the test are enclosed in a molded plastic cassette with a sample well and an observation window. No specialized equipment is required to use these tests or to score the results seen in the observation window; however, the utility of these tests can be enhanced if an electronic record of the test results can be obtained, preferably by a small hand-held device that could be used in the field under low light conditions. Such a device should also be able to “read” the lateral flow strips and accurately record the results of the test as either positive, i.e., the body fluid was detected, or negative, i.e., the body fluid was not detected. Here we describe the RSID™ Reader System—a ruggedized strip test reader unit that allows analysis and documentation of RSID™ lateral flow strip tests using pre-configured settings, and show that the RSID™ Reader can accurately and reproducibly report and record correct results from RSID™ blood, saliva, semen, and urine tests.

  4. Stand-alone flat-plate photovoltaic power systems: System sizing and life-cycle costing methodology for Federal agencies

    Science.gov (United States)

    Borden, C. S.; Volkmer, K.; Cochrane, E. H.; Lawson, A. C.

    1984-01-01

    A simple methodology to estimate photovoltaic system size and life-cycle costs in stand-alone applications is presented. It is designed to assist engineers at Government agencies in determining the feasibility of using small stand-alone photovoltaic systems to supply ac or dc power to the load. Photovoltaic system design considerations are presented as well as the equations for sizing the flat-plate array and the battery storage to meet the required load. Cost effectiveness of a candidate photovoltaic system is based on comparison with the life-cycle cost of alternative systems. Examples of alternative systems addressed are batteries, diesel generators, the utility grid, and other renewable energy systems.

  5. WRITER'S STRATEGIES IN THE INTERCOURSE WITH THE READER IN BELLES-LETTRES

    Directory of Open Access Journals (Sweden)

    Alexander S. Komarov

    2014-01-01

    Full Text Available The article is devoted to some strategies aimed at involving the reader into the writer's book by means of making the reader's attitude to its content personal or subjective. In the article it is stated that there are two components which are intrinsic to virtual intercourse between writer and reader. One of the components is the content of the writer's publication while the other is the reader's attitude towards the content suggested. The article shows that the reader's attitude encompasses two processes: the process of self-estrangement from the writer's content and the process of self-involvement into it. In the article, the author analyses these two processes in relation to the content of the book. In the article, the author singles out and gives descriptions of such dimensions of the book's content as its topical and emotional dimension, its depth, human nature dimension and interpersonal relations dimension as well as of strategies used by the writer in order to involve the reader into his writings. The author argues that a successful strategy is based on managing to touch the reader to the quick, i.e. his or her subjectivity, and the result of successfulness can be measured by the reader's readiness and willingness to sink into one of the dimensions suggested. The author of the article comes to the conclusion that signs of the successful strategy can be traced in the reader's return to the intercourse with the writer when he or she rereads the writer's books, repeats or makes references to words, situations or ideas suggested or described by the writer who has grasped the reader's attention in one or several content dimensions.

  6. RAC-Multi: Reader Anti-Collision Algorithm for Multichannel Mobile RFID Networks

    Directory of Open Access Journals (Sweden)

    Kwangcheol Shin

    2009-12-01

    Full Text Available At present, RFID is installed on mobile devices such as mobile phones or PDAs and provides a means to obtain information about objects equipped with an RFID tag over a multi-channeled telecommunication networks. To use mobile RFIDs, reader collision problems should be addressed given that readers are continuously moving. Moreover, in a multichannel environment for mobile RFIDs, interference between adjacent channels should be considered. This work first defines a new concept of a reader collision problem between adjacent channels and then suggests a novel reader anti-collision algorithm for RFID readers that use multiple channels. To avoid interference with adjacent channels, the suggested algorithm separates data channels into odd and even numbered channels and allocates odd-numbered channels first to readers. It also sets an unused channel between the control channel and data channels to ensure that control messages and the signal of the adjacent channel experience no interference. Experimental results show that suggested algorithm shows throughput improvements ranging from 29% to 46% for tag identifications compared to the GENTLE reader anti-collision algorithm for multichannel RFID networks.

  7. The Golosyiv plate archive digitisation

    Science.gov (United States)

    Sergeeva, T. P.; Sergeev, A. V.; Pakuliak, L. K.; Yatsenko, A. I.

    2007-08-01

    The plate archive of the Main Astronomical Observatory of the National Academy of Sciences of Ukraine (Golosyiv, Kyiv) includes about 85 000 plates which have been taken in various observational projects during 1950-2005. Among them are about 25 000 of direct northern sky area plates and more than 600 000 plates containing stellar, planetary and active solar formations spectra. Direct plates have a limiting magnitude of 14.0-16.0 mag. Since 2002 we have been organising the storage, safeguarding, cataloguing and digitization of the plate archive. The very initial task was to create the automated system for detection of astronomical objects and phenomena, search of optical counterparts in the directions of gamma-ray bursts, research of long period, flare and other variable stars, search and rediscovery of asteroids, comets and other Solar System bodies to improve the elements of their orbits, informational support of CCD observations and space projects, etc. To provide higher efficiency of this work we have prepared computer readable catalogues and database for 250 000 direct wide field plates. Now the catalogues have been adapted to Wide Field Plate Database (WFPDB) format and integrated into this world database. The next step will be adaptation of our catalogues, database and images to standards of the IVOA. Some magnitude and positional accuracy estimations for Golosyiv archive plates have been done. The photometric characteristics of the images of NGC 6913 cluster stars on two plates of the Golosyiv's double wide angle astrograph have been determined. Very good conformity of the photometric characteristics obtained with external accuracies of 0.13 and 0.15 mag. has been found. The investigation of positional accuracy have been made with A3± format fixed bed scanner (Microtek ScanMaker 9800XL TMA). It shows that the scanner has non-detectable systematic errors on the X-axis, and errors of ± 15 μm on the Y-axis. The final positional errors are about ± 2 μm (

  8. Accelerated Reader Program: What Do Teachers Really Think?

    Science.gov (United States)

    Smith, Amy Frances; Westberg, Karen; Hejny, Anne

    2017-01-01

    What do teachers really think about the Accelerated Reader program, a widely used supplemental, independent reading program in which their students read fiction and non-fiction books of their choice and take brief online comprehension quizzes about the books? The Accelerated Reader (AR) program was designed by Renaissance Learning Company to…

  9. Spectrophotometric determination of various polyanions with polymeric film optodes using microtiter plate reader.

    Science.gov (United States)

    Dürüst, Nedime; Meyerhoff, Mark E; Unal, Nazangül; Naç, Sibel

    2011-08-05

    Polycation-sensitive membrane optodes based on the chromoionophore 2',7'-dichlorofluorescein octadecylester (DCFOE) have previously been developed and used for determination of heparin via a titrimetric method. In this study, it is shown that some other important polyanions such as PPS (pentosan polysulfate), DNA, xanthan, Na-alginate, and carrageenan (food additive) can also be readily determined by using DCFOE-based microtiter plate-format optodes (MPOs) and polycationic titrants that bind these polyanionic species. The optical sensors are prepared with poly(vinyl chloride) (PVC), polyurethane (PU), bis(2-ethylhexyl)sebacate (DOS), and 2',7'-dichlorofluorescein octadecylester (DCFOE) and exhibit reproducible and sensitive absorbance changes in response to the varying polycationic titrant concentrations. Three different polycations; protamine, poly-l-lysine and poly-l-arginine, are employed as titrants. The method has a detection limit of 1 μg mL(-1), and a dynamic range of 1-40 μg mL(-1). After the quantitative determinations are successfully demonstrated in buffered solutions, similar titrations are also performed in real samples. The method is validated by recovery studies in these samples. The average polyanion recoveries were quantitative [99.7(±1.3) % for pastry cream with vanillin (protamine titrant); 100.4 (±3.3) % for pastry gel with strawberry(PLA titrant), and 102.9(±2.0) % for pastry gel with strawberry (PLL titrant)]. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Subduction and Plate Edge Tectonics in the Southern Caribbean

    Science.gov (United States)

    Levander, A.; Schmitz, M.; Niu, F.; Bezada, M. J.; Miller, M. S.; Masy, J.; Ave Lallemant, H. G.; Pindell, J. L.; Bolivar Working Group

    2013-05-01

    The southern Caribbean plate boundary consists of a subduction zone at at either end of a complex strike-slip fault system: In the east at the Lesser Antilles subduction zone, the Atlantic part of the South American plate subducts beneath the Caribbean. In the north and west in the Colombia basin, the Caribbean subducts under South America. In a manner of speaking, the two plates subduct beneath each other. Finite-frequency teleseismic P-wave tomography confirms this, imaging the Atlantic and the Caribbean plates subducting steeply in opposite directions to transition zone depths under northern South America (Bezada et al, 2010). The two subduction zones are connected by the El Pilar-San Sebastian strike-slip fault system, a San Andreas scale system that has been cut off at the Bocono fault, the southeastern boundary fault of the Maracaibo block. A variety of seismic probes identify subduction features at either end of the system (Niu et al, 2007; Clark et al., 2008; Miller et al. 2009; Growdon et al., 2009; Huang et al., 2010; Masy et al, 2011). The El Pilar system forms at the southeastern corner of the Antilles subduction zone with the Atlantic plate tearing from South America. The deforming plate edges control mountain building and basin formation at the eastern end of the strike-slip system. Tearing the Atlantic plate from the rest of South America appears to cause further lithospheric instability continentward. In northwestern South America the Caribbean plate very likely also tears, as its southernmost element subducts at shallow angles under northernmost Colombia but then rapidly descends to the transition zone under Lake Maracaibo (Bezada et al., 2010). We believe that the flat slab controls the tectonics of the Neogene Merida Andes, Perija, and Santa Marta ranges. The nonsubducting part of the Caribbean plate also underthrusts northern Venezuela to about the width of the coastal mountains (Miller et al., 2009). We infer that the edge of the underthrust

  11. Studies on the hydrodynamic properties of the sieve plate pulsed column for 30% TRPO-kerosene/nitric acid system

    International Nuclear Information System (INIS)

    Ma Ronglin; Chen Jing; Xu Shiping; Wu Qiulin; Tai Derong; Song Chongli

    2000-01-01

    The hydrodynamic properties of the sieve plate pulsed column for 30% TRPO-kerosene/nitric acid system is studied. With the organic phase or aqueous phase as the continuous one, the dispersed phase behaves mainly as coalescing or dispersing, respectively. The sieve plate pulsed column has a fairish flooding throughput for this system. Under the same pulsation intensity, the flooding throughput for the organic phase as the continuous one is more than that for the aqueous phase as the continuous one

  12. Numerical Investigation of a Tuned Heave Plate Energy-Harvesting System of a Semi-Submersible Platform

    Directory of Open Access Journals (Sweden)

    Kun Liu

    2016-01-01

    Full Text Available A novel tuned heave plate energy-harvesting system (THPEH is presented for the motion suppressing and energy harvesting of a semi-submersible platform. This THPEH system is designed based on the principle of a tuned mass damper (TMD and is composed of spring supports, a power take-off system (PTO and four movable heave plates. The permanent magnet linear generators (PMLG are used as the PTO system in this design. A semi-submersible platform operating in the South China Sea is selected as the research subject for investigating the effects of the THPEH system on motion reduction and harvesting energy through numerical simulations. The numerical model of the platform and the THPEH system, which was established based on hydrodynamic analysis, is modified and validated by the results of the flume test of a 1:70 scale model. The effects of the parameters, including the size, the frequency ratio and the damping ratio of the THPEH system, are systematically investigated. The results show that this THPEH system, with proper parameters, could significantly reduce the motions of the semi-submersible platform and generate considerable power under different wave conditions.

  13. Organizing Instruction for Struggling Readers in Tutorial Settings

    Science.gov (United States)

    Mokhtari, Kouider; Hutchison, Amy C.; Edwards, Patricia A.

    2010-01-01

    In this article, the authors suggest that many of the problems struggling readers encounter while reading stem from distinct yet fundamental sources of difficulty related to the types of text read (print or online), the task or activity readers engage in, and the sociocultural context of reading. The authors further argue that although these…

  14. General purpose - expert system for the analysis and design of base plates

    International Nuclear Information System (INIS)

    Al-Shawaf, T.D.; Hahn, W.F.; Ho, A.D.

    1987-01-01

    As an expert system, the IMPLATE program uses plant specific information to make decisions in modeling and analysis of baseplates. The user supplies a minimum of information which is checked for validity and reasonableness. Once this data is supplied, the program automatically generates a compatible mesh and finite element model from its data base accounting for the attachments, stiffeners, anchor bolts and plate/concrete interface. Based on the loading direction, the program deletes certain degrees of freedom and performs a linear or a nonlinear solution, whichever is appropriate. Load step sizes and equilibrium iteration are automatically selected by the program to ensure a convergent solution. Once the analysis is completed, a code check is then performed and a summary of results is produced. Plots of the plate deformation pattern and stress contours are also generated. (orig.)

  15. The parameterization of microchannel-plate-based detection systems

    Science.gov (United States)

    Gershman, Daniel J.; Gliese, Ulrik; Dorelli, John C.; Avanov, Levon A.; Barrie, Alexander C.; Chornay, Dennis J.; MacDonald, Elizabeth A.; Holland, Matthew P.; Giles, Barbara L.; Pollock, Craig J.

    2016-10-01

    The most common instrument for low-energy plasmas consists of a top-hat electrostatic analyzer (ESA) geometry coupled with a microchannel-plate-based (MCP-based) detection system. While the electrostatic optics for such sensors are readily simulated and parameterized during the laboratory calibration process, the detection system is often less well characterized. Here we develop a comprehensive mathematical description of particle detection systems. As a function of instrument azimuthal angle, we parameterize (1) particle scattering within the ESA and at the surface of the MCP, (2) the probability distribution of MCP gain for an incident particle, (3) electron charge cloud spreading between the MCP and anode board, and (4) capacitive coupling between adjacent discrete anodes. Using the Dual Electron Spectrometers on the Fast Plasma Investigation on NASA's Magnetospheric Multiscale mission as an example, we demonstrate a method for extracting these fundamental detection system parameters from laboratory calibration. We further show that parameters that will evolve in flight, namely, MCP gain, can be determined through application of this model to specifically tailored in-flight calibration activities. This methodology provides a robust characterization of sensor suite performance throughout mission lifetime. The model developed in this work is not only applicable to existing sensors but also can be used as an analytical design tool for future particle instrumentation.

  16. Flexible electronics enters the e-reader market

    Science.gov (United States)

    Banks, Michael

    2010-02-01

    A company that was spun off from the physics department at the University of Cambridge in the UK 10 years ago released its first product last month. Plastic Logic, founded by Henning Sirringhaus and Richard Friend, launched an electronic reader that can display books, magazines and newspapers on a flexible, lightweight plastic display. The reader commercializes pioneering work first started over 20 years ago at the lab by the two physicists, who are based in the department's optoelectronics group.

  17. A general audiovisual temporal processing deficit in adult readers with dyslexia

    NARCIS (Netherlands)

    Francisco, A.A.; Jesse, A.; Groen, M.A.; McQueen, J.M.

    2017-01-01

    Purpose: Because reading is an audiovisual process, reading impairment may reflect an audiovisual processing deficit. The aim of the present study was to test the existence and scope of such a deficit in adult readers with dyslexia. Method: We tested 39 typical readers and 51 adult readers with

  18. A study and development of a system for the determination of porus plates permeability

    International Nuclear Information System (INIS)

    Leitao Junior, C.B.; Zorzetto, L.F.

    1989-07-01

    A device employed for the study of flux in porous media and another one employed for the determination of permeability of porous plate are presented in this work. Experimental data and calculation obtained from the above cited systems are also presented. (author) [pt

  19. Advanced Extended Plate and Beam Wall System in a Cold-Climate House

    Energy Technology Data Exchange (ETDEWEB)

    Mallay, Dave [Home Innovation Research Labs, Upper Marlboro, MD (United States); Wiehagen, Joseph [Home Innovation Research Labs, Upper Marlboro, MD (United States); Kochkin, Vladimir [Home Innovation Research Labs, Upper Marlboro, MD (United States)

    2016-01-29

    This report presents the design and evaluation of an innovative wall system. This highly insulated (high-R) light-frame wall system for use above grade in residential buildings is referred to as Extended Plate & Beam (EP&B). The EP&B design is the first of its kind to be featured in a new construction test house (NCTH) for the DOE Building America program. The EP&B wall design integrates standard building methods and common building products to construct a high-R wall that minimizes transition risks and costs to builders. The EP&B design combines optimized framing with integrated rigid foam sheathing to increase the wall system's R-value and reduce thermal bridging. The foam sheathing is installed between the wall studs and structural wood sheathing. The exterior wood sheathing is attached directly to a framing extension formed by extended top and bottom plates. The exterior wood sheathing can dry to the exterior and provides bracing, a clear drainage plane and flashing surface for window and door openings, and a nailing surface for siding attachment. With support of the DOE Building America program, Home Innovation Research Labs partnered with Lancaster County Career and Technology Center (LCCTC) to build a NCTH in Lancaster, PA to demonstrate the EP&B wall design in a cold climate (IECC climate zone 5A). The results of the study confirmed the benefits of the systems and the viability of its integration into the house construction process.

  20. Developmental Trajectories for Children With Dyslexia and Low IQ Poor Readers

    Science.gov (United States)

    2016-01-01

    Reading difficulties are found in children with both high and low IQ and it is now clear that both groups exhibit difficulties in phonological processing. Here, we apply the developmental trajectories approach, a new methodology developed for studying language and cognitive impairments in developmental disorders, to both poor reader groups. The trajectory methodology enables identification of atypical versus delayed development in datasets gathered using group matching designs. Regarding the cognitive predictors of reading, which here are phonological awareness, phonological short-term memory (PSTM) and rapid automatized naming (RAN), the method showed that trajectories for the two groups diverged markedly. Children with dyslexia showed atypical development in phonological awareness, while low IQ poor readers showed developmental delay. Low IQ poor readers showed atypical PSTM and RAN development, but children with dyslexia showed developmental delay. These divergent trajectories may have important ramifications for supporting each type of poor reader, although all poor readers showed weakness in all areas. Regarding auditory processing, the developmental trajectories were very similar for the two poor reader groups. However, children with dyslexia demonstrated developmental delay for auditory discrimination of Duration, while the low IQ children showed atypical development on this measure. The data show that, regardless of IQ, poor readers have developmental trajectories that differ from typically developing children. The trajectories approach enables differences in trajectory classification to be identified across poor reader group, as well as specifying the individual nature of these trajectories. PMID:27110928

  1. Effects of Damping Plate and Taut Line System on Mooring Stability of Small Wave Energy Converter

    Directory of Open Access Journals (Sweden)

    Zhen Liu

    2015-01-01

    Full Text Available Ocean wave energy can be used for electricity supply to ocean data acquisition buoys. A heaving buoy wave energy converter is designed and the damping plate and taut line system are used to provide the mooring stability for better operating conditions. The potential flow assumption is employed for wave generation and fluid structure interactions, which are processed by the commercial software AQWA. Effects of damping plate diameter and taut line linking style with clump and seabed weights on reduction of displacements in 6 degrees of freedom are numerically studied under different operating wave conditions. Tensile forces on taut lines of optimized mooring system are tested to satisfy the national code for wire rope utilization.

  2. Cold plate

    Energy Technology Data Exchange (ETDEWEB)

    Marroquin, Christopher M.; O' Connell, Kevin M.; Schultz, Mark D.; Tian, Shurong

    2018-02-13

    A cold plate, an electronic assembly including a cold plate, and a method for forming a cold plate are provided. The cold plate includes an interface plate and an opposing plate that form a plenum. The cold plate includes a plurality of active areas arranged for alignment over respective heat generating portions of an electronic assembly, and non-active areas between the active areas. A cooling fluid flows through the plenum. The plenum, at the non-active areas, has a reduced width and/or reduced height relative to the plenum at the active areas. The reduced width and/or height of the plenum, and exterior dimensions of cold plate, at the non-active areas allow the non-active areas to flex to accommodate surface variations of the electronics assembly. The reduced width and/or height non-active areas can be specifically shaped to fit between physical features of the electronics assembly.

  3. Modeling the hydrodynamics of phloem sieve plates

    Directory of Open Access Journals (Sweden)

    Kaare Hartvig Jensen

    2012-07-01

    Full Text Available Sieve plates have an enormous impact on the efficiency of the phloem vascular system of plants, responsible for the distribution of photosynthetic products. These thin plates, which separate neighboring phloem cells, are perforated by a large number of tiny sieve pores and are believed to play a crucial role in protecting the phloem sap from intruding animals by blocking flow when the phloem cell is damaged. The resistance to the flow of viscous sap in the phloem vascular system is strongly affected by the presence of the sieve plates, but the hydrodynamics of the flow through them remains poorly understood. We propose a theoretical model for quantifying the effect of sieve plates on the phloem in the plant, thus unifying and improving previous work in the field. Numerical simulations of the flow in real and idealized phloem channels verify our model, and anatomical data from 19 plant species are investigated. We find that the sieve plate resistance is correlated to the cell lumen resistance, and that the sieve plate and the lumen contribute almost equally to the total hydraulic resistance of the phloem translocation pathway.

  4. Image simulation for automatic license plate recognition

    Science.gov (United States)

    Bala, Raja; Zhao, Yonghui; Burry, Aaron; Kozitsky, Vladimir; Fillion, Claude; Saunders, Craig; Rodríguez-Serrano, José

    2012-01-01

    Automatic license plate recognition (ALPR) is an important capability for traffic surveillance applications, including toll monitoring and detection of different types of traffic violations. ALPR is a multi-stage process comprising plate localization, character segmentation, optical character recognition (OCR), and identification of originating jurisdiction (i.e. state or province). Training of an ALPR system for a new jurisdiction typically involves gathering vast amounts of license plate images and associated ground truth data, followed by iterative tuning and optimization of the ALPR algorithms. The substantial time and effort required to train and optimize the ALPR system can result in excessive operational cost and overhead. In this paper we propose a framework to create an artificial set of license plate images for accelerated training and optimization of ALPR algorithms. The framework comprises two steps: the synthesis of license plate images according to the design and layout for a jurisdiction of interest; and the modeling of imaging transformations and distortions typically encountered in the image capture process. Distortion parameters are estimated by measurements of real plate images. The simulation methodology is successfully demonstrated for training of OCR.

  5. Automated Low-Cost Smartphone-Based Lateral Flow Saliva Test Reader for Drugs-of-Abuse Detection

    Directory of Open Access Journals (Sweden)

    Adrian Carrio

    2015-11-01

    Full Text Available Lateral flow assay tests are nowadays becoming powerful, low-cost diagnostic tools. Obtaining a result is usually subject to visual interpretation of colored areas on the test by a human operator, introducing subjectivity and the possibility of errors in the extraction of the results. While automated test readers providing a result-consistent solution are widely available, they usually lack portability. In this paper, we present a smartphone-based automated reader for drug-of-abuse lateral flow assay tests, consisting of an inexpensive light box and a smartphone device. Test images captured with the smartphone camera are processed in the device using computer vision and machine learning techniques to perform automatic extraction of the results. A deep validation of the system has been carried out showing the high accuracy of the system. The proposed approach, applicable to any line-based or color-based lateral flow test in the market, effectively reduces the manufacturing costs of the reader and makes it portable and massively available while providing accurate, reliable results.

  6. Automated Low-Cost Smartphone-Based Lateral Flow Saliva Test Reader for Drugs-of-Abuse Detection.

    Science.gov (United States)

    Carrio, Adrian; Sampedro, Carlos; Sanchez-Lopez, Jose Luis; Pimienta, Miguel; Campoy, Pascual

    2015-11-24

    Lateral flow assay tests are nowadays becoming powerful, low-cost diagnostic tools. Obtaining a result is usually subject to visual interpretation of colored areas on the test by a human operator, introducing subjectivity and the possibility of errors in the extraction of the results. While automated test readers providing a result-consistent solution are widely available, they usually lack portability. In this paper, we present a smartphone-based automated reader for drug-of-abuse lateral flow assay tests, consisting of an inexpensive light box and a smartphone device. Test images captured with the smartphone camera are processed in the device using computer vision and machine learning techniques to perform automatic extraction of the results. A deep validation of the system has been carried out showing the high accuracy of the system. The proposed approach, applicable to any line-based or color-based lateral flow test in the market, effectively reduces the manufacturing costs of the reader and makes it portable and massively available while providing accurate, reliable results.

  7. French Immersion Experience and Reading Skill Development in At-Risk Readers

    Science.gov (United States)

    Kruk, Richard S.; Reynolds, Kristin A. A.

    2012-01-01

    We tracked the developmental influences of exposure to French on developing English phonological awareness, decoding and reading comprehension of English-speaking at-risk readers from Grade 1 to Grade 3. Teacher-nominated at-risk readers were matched with not-at-risk readers in French immersion and English language programs. Exposure to spoken…

  8. Advanced Extended Plate and Beam Wall System in a Cold-Climate House

    Energy Technology Data Exchange (ETDEWEB)

    Mallay, Dave [Partnership for Home Innovation, Upper Marlboro, MD (United States); Wiehagen, Joseph [Partnership for Home Innovation, Upper Marlboro, MD (United States); Kochkin, Vladimir [Partnership for Home Innovation, Upper Marlboro, MD (United States)

    2016-01-01

    This report presents the design and evaluation of an innovative wall system. This highly insulated (high-R) light-frame wall system for use above grade in residential buildings is referred to as Extended Plate & Beam (EP&B). The EP&B design is the first of its kind to be featured in a new construction test house (NCTH) for the DOE Building America program. The EP&B wall design integrates standard building methods and common building products to construct a high-R wall that minimizes transition risks and costs to builders.

  9. [Physiological and hygienic assessment of perception of the information from electronic device for reading (reader)].

    Science.gov (United States)

    Kuchma, V R; Teksheva, L M; Vyatleva, O A; Kurgansky, A M

    2013-01-01

    A comparison of the legibility of the three different media: paper personal computer (LCD) and the e-reader in schoolchildren (12-14 years of age) was performed. Comprehensive assessment of the reading performance (speed of reading aloud, the number of errors in reading, and integral indicator of the degree of difficulty of visual task), its physiological value (according to data of EEG, EOG and ECG), and subjective preference of type of media by the schoolchildren showed that by the sum of signs e-reader occupies an intermediate position between printed text and the computer screen. The effect of increased emotional intensity of using e-reader (increased motivation), which is manifested in the preservation of the sympathetic nervous system activation after the reading, was obtained. The necessity of additional research has been shown.

  10. Beyond Library Power: Reader's Digest Adds Public Libraries to the Mix.

    Science.gov (United States)

    Rockfield, Gary

    1998-01-01

    Describes the Tall Tree Initiative for Library Services, sponsored by the Reader's Digest Foundation and administered by the public and school library systems of Westchester County, New York. The initiative focuses on improving services offered children in the 21st century, and demands a new level of school-public library cooperation. (AEF)

  11. Postdecisional counterfactual thinking by actors and readers.

    Science.gov (United States)

    Girotto, Vittorio; Ferrante, Donatella; Pighin, Stefania; Gonzalez, Michel

    2007-06-01

    How do individuals think counterfactually about the outcomes of their decisions? Most previous studies have investigated how readers think about fictional stories, rather than how actors think about events they have actually experienced. We assumed that differences in individuals' roles (actor vs. reader) can make different information available, which in turn can affect counterfactual thinking. Hence, we predicted an effect of role on postdecisional counterfactual thinking. Reporting the results of eight studies, we show that readers undo the negative outcome of a story by undoing the protagonist's choice to tackle a given problem, rather than the protagonist's unsuccessful attempt to solve it. But actors who make the same choice and experience the same negative outcome as the protagonist undo this outcome by altering features of the problem. We also show that this effect does not depend on motivational factors. These results contradict current accounts of counterfactual thinking and demonstrate the necessity of investigating the counterfactual thoughts of individuals in varied roles.

  12. Selecting literature for beginner readers in South Africa

    Directory of Open Access Journals (Sweden)

    Hibbert, Liesel

    2011-12-01

    Full Text Available This article explores complexities of choosing appropriate reading material which may provide maximum engagement for beginner readers in Southern Africa, with the aim of instilling a lifelong love of reading. The article presents a case in favour of literary criteria as base line for choices of reading material for beginner readers. Furthermore, the article outlines general characteristics of reading material for beginner readers, as well as specific criteria to be considered in the Southern African context, taking into account the linguistic diversity which exists in formal education and the vast literacy backlog in the region. Furthermore, it is argued that translated children’s stories should ideally be adapted rather than literally translated, in order to meet the requirements of what is universally regarded as good children’s literature for beginner readers. A culture of reading can only be instilled by adhering to the following criteria, i.e. ensuring affective engagement, maximum meaning-making potential, delight, the engagement of the imagination for the purposes of developing the creative mind, and strong identification with the material for the purposes of developing a sense of agency.

  13. Resolving Struggling Readers' Homework Difficulties: A Social Cognitive Perspective

    Science.gov (United States)

    Margolis, Howard; Mccabe, Patrick

    2004-01-01

    Struggling readers often fail to complete homework or complete it in a slipshod, haphazard fashion. Often, this adversely affects grades, erodes motivation for academics, and causes conflict between readers, parents, and school personnel. To help teachers and educational consultants (e.g., reading specialists, school psychologists) help struggling…

  14. A General Audiovisual Temporal Processing Deficit in Adult Readers with Dyslexia

    Science.gov (United States)

    Francisco, Ana A.; Jesse, Alexandra; Groen, Margriet A.; McQueen, James M.

    2017-01-01

    Purpose: Because reading is an audiovisual process, reading impairment may reflect an audiovisual processing deficit. The aim of the present study was to test the existence and scope of such a deficit in adult readers with dyslexia. Method: We tested 39 typical readers and 51 adult readers with dyslexia on their sensitivity to the simultaneity of…

  15. Growing Young Gifted Readers

    Science.gov (United States)

    Wood, Patricia F.

    2009-01-01

    There is great pressure on parents to teach children to read as early as possible. In reality, precocious (early advanced) readers seem to almost master the skill on their own, without the assistance of highly touted, commercially available programs. The 18-month-old toddler who names the letters on alphabet blocks; or the 26-month-old who can…

  16. Reader survey

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Many, thanks to the hundreds of people who took the time to reply to the CERN Courier readership survey questionnaire published in our May issue. Bringing out a monthly journal is a lonely business. Issue after issue goes out, and the only response is when there's an occasional factual error. Send out a readership survey and a faint echo comes back. Most striking was the sheer enthusiasm of the replies. Despite the current erosion of support in the US (see page 2), subatomic physics has significant world-wide box-office appeal. Most important was to find out who our readers are. 61% of the replies came from Europe, 21% from the USA, 14% from elsewhere, (including the former Soviet Union), and 4% from inside CERN. Not surprisingly, the main audience (37%) is in the high energy physics sector. Then comes teaching (31%), followed closely by accelerators operations and design (12%) and industry (11%). Apart from detailed breakdowns of readership and feedback on the journal's content and style, the replies revealed several major features. Firstly, the CERN Courier is widely read and appreciated. There are a lot of people outside the immediate research field who want to keep broadly up to date with the latest developments in high energy physics and related fields, without getting too involved in details. It was gratifying to receive replies from far-flung places (Nepal, Indonesia,....), and learn how much distant readers appreciate getting such regular information. 'It helps us feel part of the world scene,' was a typical such reply, from Australia. Despite jet airplanes, fax and electronic mail, our planet is still big

  17. Reader survey

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1993-10-15

    Many, thanks to the hundreds of people who took the time to reply to the CERN Courier readership survey questionnaire published in our May issue. Bringing out a monthly journal is a lonely business. Issue after issue goes out, and the only response is when there's an occasional factual error. Send out a readership survey and a faint echo comes back. Most striking was the sheer enthusiasm of the replies. Despite the current erosion of support in the US (see page 2), subatomic physics has significant world-wide box-office appeal. Most important was to find out who our readers are. 61% of the replies came from Europe, 21% from the USA, 14% from elsewhere, (including the former Soviet Union), and 4% from inside CERN. Not surprisingly, the main audience (37%) is in the high energy physics sector. Then comes teaching (31%), followed closely by accelerators operations and design (12%) and industry (11%). Apart from detailed breakdowns of readership and feedback on the journal's content and style, the replies revealed several major features. Firstly, the CERN Courier is widely read and appreciated. There are a lot of people outside the immediate research field who want to keep broadly up to date with the latest developments in high energy physics and related fields, without getting too involved in details. It was gratifying to receive replies from far-flung places (Nepal, Indonesia,....), and learn how much distant readers appreciate getting such regular information. 'It helps us feel part of the world scene,' was a typical such reply, from Australia. Despite jet airplanes, fax and electronic mail, our planet is still big.

  18. Usability and Accessibility of eBay by Screen Reader

    Science.gov (United States)

    Buzzi, Maria Claudia; Buzzi, Marina; Leporini, Barbara; Akhter, Fahim

    The evolution of Information and Communication Technology and the rapid growth of the Internet have fuelled a great diffusion of eCommerce websites. Usually these sites have complex layouts crowded with active elements, and thus are difficult to navigate via screen reader. Interactive environments should be properly designed and delivered to everyone, including the blind, who usually use screen readers to interact with their computers. In this paper we investigate the interaction of blind users with eBay, a popular eCommerce website, and discuss how using the W3C Accessible Rich Internet Applications (WAI-ARIA) suite could improve the user experience when navigating via screen reader.

  19. Policy Reader

    International Nuclear Information System (INIS)

    1985-09-01

    This policy reader comprises: Correspondence; Memorandum of Understanding between the US Department of Transportation and the US Department of Energy for the Transportation of Radioactive Materials under the Nuclear Waste Policy Act; Internal Guidelines for Interactions with Communities and Local Governments; Statement by Ben C. Rusche before the Committee on Interior and Insular Affairs, Subcommittee on Energy and the Environment, US House of Representatives, September 13, 1985; Speech presented by Ben C. Rusche before the ANS/CNS/AESJ/ENS Topical Meeting, Pasco, Washington, September 24, 1985 - ''Status of the United States' High-Level Nuclear Waste Disposal Program''; and ''DOE Seeks Comments on Nuclear Transportation Planning,'' DOE News, September 30, 1985

  20. Teaching Early Readers to Self-Monitor and Self-Correct

    Science.gov (United States)

    Pratt, Sharon M.; Urbanowski, Melena

    2016-01-01

    Proficient readers self-monitor and self-correct to derive meaning from text. This article reviews research on how students learn to self-monitor and self-correct and describes a Reciprocal Teaching (RT) instructional routine that was successfully used with early readers to build their metacognitive processes. The RT routine included teacher…

  1. Proceedings of the flat-plate solar array project research forum on photovoltaic metallization systems

    Energy Technology Data Exchange (ETDEWEB)

    None

    1983-11-15

    A Photovoltaic Metallization Research Forum, under the sponsorship of the Jet Propulsion Laboratory's Flat-Plate Solar Array Project and the US Department of Energy, was held March 16-18, 1983 at Pine Mountain, Georgia. The Forum consisted of five sessions, covering (1) the current status of metallization systems, (2) system design, (3) thick-film metallization, (4) advanced techniques and (5) future metallization challenges. Twenty-three papers were presented.

  2. Using Twitter to Teach Reader-Oriented Biblical Interpretation: "Tweading" the Gospel of Mark

    Science.gov (United States)

    Williamson, Robert, Jr.

    2013-01-01

    Twitter offers an engaging way to introduce students to reader-oriented interpretation of the Bible. The exercise described here introduces students to the idea that the reader has a role in the production of a text's meaning, which thus varies from reader to reader. Twitter enables us to capture the real-time thoughts of a variety of…

  3. A critical appraisal of the phene-plate biochemical fingerprinting system for epidemiological subtyping of Salmonella typhimurium

    DEFF Research Database (Denmark)

    On, S.L.W.; Baggesen, Dorte Lau

    1996-01-01

    The efficacy and reproducibility of the Phene-Plate (PhP) system (Biosys Inova, Stockholm, Sweden) for biochemical fingerprinting of Salmonella typhimurium was investigated. Duplicate and replicate assays on 40 epidemiologically related and unrelated strains were performed in two batches of PhP-48......P-types which are epidemiologically unjustified, (ii) tests currently recommended for PhP-typing S. typhimurium may be somewhat unstable and not satisfactory for fingerprinting purposes, (iii) caution must be exercised when comparing data from different batches of PhP-48 plates, and (iv) best results...

  4. Characterization of an in vivo thyroid 131I monitoring system using an imaging plate

    International Nuclear Information System (INIS)

    Hirota, Masahiro; Saze, Takuya; Nishizawa, Kunihide

    2004-01-01

    The effects of neck diameter, thyroid volume, and prethyroid tissue thickness on a count-activity conversion coefficient and the detection limit of a thyroid 131 I monitoring system with an imaging plate (IP) were estimated by using an anthropomorphic thyroid-neck phantom. The conversion coefficient and detection limit of the IP system was approximately constant for normal Japanese adults regardless of their neck diameters, thyroid volumes, and prethyroid tissue thicknesses. The IP system is a new option for thyroid 131 I monitoring

  5. Resorbable versus titanium plates for orthognathic surgery.

    Science.gov (United States)

    Agnihotry, Anirudha; Fedorowicz, Zbys; Nasser, Mona; Gill, Karanjot S

    2017-10-04

    Recognition of some of the limitations of titanium plates and screws used for the fixation of bones has led to the development of plates manufactured from bioresorbable materials. Whilst resorbable plates appear to offer clinical advantages over metal plates in orthognathic surgery, concerns remain about the stability of fixation and the length of time required for their degradation and the possibility of foreign body reactions. This review compares the use of titanium versus bioresorbable plates in orthognathic surgery and is an update of the Cochrane Review first published in 2007. To compare the effects of bioresorbable fixation systems with titanium systems used during orthognathic surgery. Cochrane Oral Health's Information Specialist searched the following databases: Cochrane Oral Health's Trials Register (to 20 January 2017); the Cochrane Central Register of Controlled Trials (CENTRAL; 2016, Issue 11) in the Cochrane Library (searched 20 January 2017); MEDLINE Ovid (1946 to 20 January 2017); and Embase Ovid (1980 to 20 January 2017). We searched the US National Institutes of Health Ongoing Trials Register ClinicalTrials.gov (clinicaltrials.gov; searched 20 January 2017), and the World Health Organization International Clinical Trials Registry Platform (searched 20 January 2017) for ongoing trials. No restrictions were placed on the language or date of publication when searching the electronic databases. Randomised controlled trials comparing bioresorbable versus titanium fixation systems used for orthognathic surgery in adults. Two review authors independently screened the results of the electronic searches, extracted data and assessed the risk of bias of the included studies. We resolved disagreement by discussion. Clinical heterogeneity between the included trials precluded pooling of data, and only a descriptive summary is presented. This review included two trials, involving 103 participants, one comparing titanium with resorbable plates and screws and

  6. Chinese Deaf Readers Have Early Access to Parafoveal Semantics

    Science.gov (United States)

    Yan, Ming; Pan, Jinger; Bélanger, Nathalie N.; Shu, Hua

    2015-01-01

    In the present study, we manipulated different types of information available in the parafovea during the reading of Chinese sentences and examined how deaf readers make use of the parafoveal information. Results clearly indicate that although the reading-level matched hearing readers make greater use of orthographic information in the parafovea,…

  7. Eye Movements Reveal Readers' Lexical Quality and Reading Experience

    Science.gov (United States)

    Taylor, Jessica Nelson; Perfetti, Charles A.

    2016-01-01

    Two experiments demonstrate that individual differences among normal adult readers, including lexical quality, are expressed in silent reading at the word level. In the first of two studies we identified major dimensions of variability among college readers and among words using factor analysis. We then examined the effects of these dimensions of…

  8. Finding versus Fixing: Self-Monitoring for Readers Who Struggle

    Science.gov (United States)

    Anderson, Nancy L.; Kaye, Elizabeth L.

    2017-01-01

    This article explains how teachers can understand, notice, and supportively respond to readers who struggle with self-monitoring during text reading. The unique strategic processing demands for readers who struggle support the argument that teaching children to find and notice errors is different than fixing a word, or getting it right. Three…

  9. Modeling the hydrodynamics of Phloem sieve plates

    DEFF Research Database (Denmark)

    Jensen, Kaare Hartvig; Mullendore, Daniel Leroy; Holbrook, Noel Michele

    2012-01-01

    Sieve plates have an enormous impact on the efficiency of the phloem vascular system of plants, responsible for the distribution of photosynthetic products. These thin plates, which separate neighboring phloem cells, are perforated by a large number of tiny sieve pores and are believed to play...... understood. We propose a theoretical model for quantifying the effect of sieve plates on the phloem in the plant, thus unifying and improving previous work in the field. Numerical simulations of the flow in real and idealized phloem channels verify our model, and anatomical data from 19 plant species...... a crucial role in protecting the phloem sap from intruding animals by blocking flow when the phloem cell is damaged. The resistance to the flow of viscous sap in the phloem vascular system is strongly affected by the presence of the sieve plates, but the hydrodynamics of the flow through them remains poorly...

  10. Thermo-mechanical analysis of the pressure plate of clutch

    Directory of Open Access Journals (Sweden)

    P.V.N. Venkata Mallikarjuna

    2017-09-01

    Full Text Available High Temperature appears in the contact surfaces of a clutch system (friction surface and pressure plate due to the relative motion between these parts during the sliding period. These high temperatures are responsible for several failures such as pressure plate crack, pressure plate warpage etc. With the help of Finite element analysis, the sliding friction process of the pressure plate and friction during clutch engagement is simulated to get temperature field characteristics and contact pressure of pressure plate.

  11. Inter-reader agreement of multi-parametric MR imaging for the detection of prostate cancer. Evaluation of a scoring system

    International Nuclear Information System (INIS)

    Quentin, M.; Roehlen, S.; Klasen, J.; Antoch, G.; Blondin, D.; Arsov, C.; Albers, P.

    2012-01-01

    Purpose: Functional prostate MR is performed in varying combinations of T2-weighted images with diffusion-weighted imaging (DWI), dynamic contrast-enhanced MRI (DCE-MRI), and spectroscopic imaging (MRSI). Recently, a European consensus meeting proposed the use of a simple 5-point scale for estimating the probability of a lesion being malignant. The aim of the present study was to determine the inter-reader agreement of MR imaging using a scoring system based on the recommendations of the consensus. Materials and Methods: The appearance of 108 predefined lesions in three different MR sequences (T2-weighted images, DWI, and DCE-MRI) in 50 functional prostate MR examinations were retrospectively scored by three blinded radiologists using a 5-point scale for each MR sequence. After scoring T2/DWI and T2/DWI/DCE-MRI, every lesion was graded based on its probability for malignancy. The inter-observer reliability was evaluated using Kappa statistics (Κ). Results: With respect to T2-weighted images, DWI and DCE-MRI Κ was 0.49, 0.97, and 0.77, respectively. Combined scoring of T2-weighted images and DWI demonstrated correct tumor diagnosis (true positive) in 71 - 88 % (depending on reader) of cases (Κ = 0.78). The accuracy was further improved to 88 - 96 % after scoring all three MR sequences including DCE-MRI (Κ = 0.90). Conclusion: The use of a simple 5-point scoring system for T2-weighted images, DWI, and DCE-MRI is feasible in functional prostate MRI and has high inter-observer reliability.

  12. Analysis of hydraulic instability of ANS involute fuel plates

    International Nuclear Information System (INIS)

    Sartory, W.K.

    1991-11-01

    Curved shell equations for the involute Advanced Neutron Source (ANS) fuel plates are coupled to two-dimensional hydraulic channel flow equations that include fluid friction. A complete set of fluid and plate boundary conditions is applied at the entrance and exit and along the sides of the plate and the channel. The coupled system is linearized and solved to assess the hydraulic instability of the plates

  13. Astrometric properties of the Tautenburg Plate Scanner

    Science.gov (United States)

    Brunzendorf, Jens; Meusinger, Helmut

    The Tautenburg Plate Scanner (TPS) is an advanced plate-measuring machine run by the Thüringer Landessternwarte Tautenburg (Karl Schwarzschild Observatory), where the machine is housed. It is capable of digitising photographic plates up to 30 cm × 30 cm in size. In our poster, we reported on tests and preliminary results of its astrometric properties. The essential components of the TPS consist of an x-y table movable between an illumination system and a direct imaging system. A telecentric lens images the light transmitted through the photographic emulsion onto a CCD line of 6000 pixels of 10 µm square size each. All components are mounted on a massive air-bearing table. Scanning is performed in lanes of up to 55 mm width by moving the x-y table in a continuous drift-scan mode perpendicular to the CCD line. The analogue output from the CCD is digitised to 12 bit with a total signal/noise ratio of 1000 : 1, corresponding to a photographic density range of three. The pixel map is produced as a series of optionally overlapping lane scans. The pixel data are stored onto CD-ROM or DAT. A Tautenburg Schmidt plate 24 cm × 24 cm in size is digitised within 2.5 hours resulting in 1.3 GB of data. Subsequent high-level data processing is performed off-line on other computers. During the scanning process, the geometry of the optical components is kept fixed. The optimal focussing of the optics is performed prior to the scan. Due to the telecentric lens refocussing is not required. Therefore, the main source of astrometric errors (beside the emulsion itself) are mechanical imperfections in the drive system, which have to be divided into random and systematic ones. The r.m.s. repeatability over the whole plate as measured by repeated scans of the same plate is about 0.5 µm for each axis. The mean plate-to-plate accuracy of the object positions on two plates with the same epoch and the same plate centre has been determined to be about 1 µm. This accuracy is comparable to

  14. LESS SKILLED READERS HAVE LESS EFFICIENT SUPPRESSION MECHANISMS

    OpenAIRE

    Gernsbacher, Morton Ann

    1993-01-01

    One approach to understanding the component processes and mechanisms underlying adult reading skill is to compare the performance of more skilled and less skilled readers on laboratory experiments. The results of some recent experiments employing this approach demonstrate that less skilled adult readers suppress less efficiently the inappropriate meanings of ambiguous words (e.g., the playing card vs. garden tool meanings of spade), the incorrect forms of homophones (e.g., patients vs. patien...

  15. Computer Games versus Maps before Reading Stories: Priming Readers' Spatial Situation Models

    Science.gov (United States)

    Smith, Glenn Gordon; Majchrzak, Dan; Hayes, Shelley; Drobisz, Jack

    2011-01-01

    The current study investigated how computer games and maps compare as preparation for readers to comprehend and retain spatial relations in text narratives. Readers create situation models of five dimensions: spatial, temporal, causal, goal, and protagonist (Zwaan, Langston, & Graesser 1995). Of these five, readers mentally model the spatial…

  16. The Usefulness Metrics of The Most Popular eReader Used by Higher Education Students

    Directory of Open Access Journals (Sweden)

    Dwi Puspita Sari

    2015-07-01

    Full Text Available In the digital technology era, mobile devices have an important rule to deploy a copy of data and information through the network. An electronic reader (eReader allows readers to read written materials in an electronic manner that is available in many models. The objective of this study is to evaluate the usage of eReader by higher education students. We firstly identified the most frequently used eReader by surveying higher education students. The survey results showed that Apple iPad, Amazon Kindle, and Samsung Tablet are the most popular eReader devices used by higher education students. We presented these results, and then we analyzed the surveyed results in detail in order to develop an evaluation metric of the eReader in a mobile platform that clearly allows the selection of the most suitable eReader for higher education students. The main contribution of this paper is the development of a set of criteria that can be used by students in the selection of an eReader that matches their specific needs and requirements.

  17. A unidirectional subwavelength focusing near-field plate

    Energy Technology Data Exchange (ETDEWEB)

    Imani, Mohammadreza F.; Grbic, Anthony [Radiation Laboratory, Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Michigan 48109 (United States)

    2014-01-28

    Near-field plates consist of non-periodically patterned surfaces that can overcome the diffraction limit and confine electromagnetic fields to subwavelength dimensions. Previous near-field plates experimentally demonstrated extreme field tailoring capabilities. However, their performance suffered from radiation/reflection in undesired directions, those other than the subwavelength focus. This issue can limit the practical use of near-field plates. In this paper, we address this issue by designing a unidirectional near-field plate that can form a subwavelength focal pattern, while suppressing the field radiated/reflected in other directions. The design and operation of the proposed unidirectional near-field plate are verified through full-wave simulation. The unidirectional near-field plate may find application in high resolution imaging and probing, high density data storage, and wireless power transfer systems. As an example, its utility as a high resolution probe is demonstrated through full-wave electromagnetic simulation.

  18. AUSES AND GRATIFICTIONS RESEARCH ON READING MOTIVATIONSE AND GRATIFICATIONS OFNEWSPAPER READERS

    OpenAIRE

    Fatih Bayram

    2008-01-01

    Giving information is one of the main function of mass communication tools. Newspaper readers are using newspaper for different motivations. Gaining information, entertainment, leisure time activities, social integration is some motivations of media. Uses and gratifications theory asserts that reader is active part of communication process and reading habits figure on social and psychological needs. Items from readers’gratifications are categorized by using factor analysis from questionnair...

  19. Analytical model development of an eddy-current-based non-contacting steel plate conveyance system

    International Nuclear Information System (INIS)

    Liu, C.-T.; Lin, S.-Y.; Yang, Y.-Y.; Hwang, C.-C.

    2008-01-01

    A concise model for analyzing and predicting the quasi-static electromagnetic characteristics of an eddy-current-based non-contacting steel plate conveyance system has been developed. Confirmed by three-dimensional (3-D) finite element analysis (FEA), adequacy of the analytical model can be demonstrated. Such an effective approach, which can be conveniently used by the potential industries for preliminary system operational performance evaluations, will be essential for designers and on-site engineers

  20. Robust multi-model predictive control of multi-zone thermal plate system

    Directory of Open Access Journals (Sweden)

    Poom Jatunitanon

    2018-02-01

    Full Text Available A modern controller was designed by using the mathematical model of a multi–zone thermal plate system. An important requirement for this type of controller is that it must be able to keep the temperature set-point of each thermal zone. The mathematical model used in the design was determined through a system identification process. The results showed that when the operating condition is changed, the performance of the controller may be reduced as a result of the system parameter uncertainties. This paper proposes a weighting technique of combining the robust model predictive controller for each operating condition into a single robust multi-model predictive control. Simulation and experimental results showed that the proposed method performed better than the conventional multi-model predictive control in rise time of transient response, when used in a system designed to work over a wide range of operating conditions.

  1. Relative range error evaluation of terrestrial laser scanners using a plate, a sphere, and a novel dual-sphere-plate target.

    Science.gov (United States)

    Muralikrishnan, Bala; Rachakonda, Prem; Lee, Vincent; Shilling, Meghan; Sawyer, Daniel; Cheok, Geraldine; Cournoyer, Luc

    2017-12-01

    Terrestrial laser scanners (TLS) are a class of 3D imaging systems that produce a 3D point cloud by measuring the range and two angles to a point. The fundamental measurement of a TLS is range. Relative range error is one component of the overall range error of TLS and its estimation is therefore an important aspect in establishing metrological traceability of measurements performed using these systems. Target geometry is an important aspect to consider when realizing the relative range tests. The recently published ASTM E2938-15 mandates the use of a plate target for the relative range tests. While a plate target may reasonably be expected to produce distortion free data even at far distances, the target itself needs careful alignment at each of the relative range test positions. In this paper, we discuss relative range experiments performed using a plate target and then address the advantages and limitations of using a sphere target. We then present a novel dual-sphere-plate target that draws from the advantages of the sphere and the plate without the associated limitations. The spheres in the dual-sphere-plate target are used simply as fiducials to identify a point on the surface of the plate that is common to both the scanner and the reference instrument, thus overcoming the need to carefully align the target.

  2. Are You Ready for E-Readers in Your Library?

    Science.gov (United States)

    Gustafson, Chris

    2012-01-01

    This article discusses some things to consider when thinking about adding e-readers to one's collection. These include: (1) What is the purpose?; (2) Which device?; (3) How will one keep track of his or her e-readers and their contents?; (4) What are some potential pitfalls?; (5) Is there a positive impact on student learning?; and (6) Are…

  3. Ponderomotive phase plate for transmission electron microscopes

    Science.gov (United States)

    Reed, Bryan W [Livermore, CA

    2012-07-10

    A ponderomotive phase plate system and method for controllably producing highly tunable phase contrast transfer functions in a transmission electron microscope (TEM) for high resolution and biological phase contrast imaging. The system and method includes a laser source and a beam transport system to produce a focused laser crossover as a phase plate, so that a ponderomotive potential of the focused laser crossover produces a scattering-angle-dependent phase shift in the electrons of the post-sample electron beam corresponding to a desired phase contrast transfer function.

  4. Radiation shielding plate

    International Nuclear Information System (INIS)

    Kobayashi, Torakichi; Sugawara, Takeo.

    1983-01-01

    Purpose: To reduce the weight and stabilize the configuration of a radiation shielding plate which is used in close contact with an object to be irradiated with radiation rays. Constitution: The radiation shielding plate comprises a substrate made of lead glass and a metallic lead coating on the surface of the substrate by means of plating, vapor deposition or the like. Apertures for permeating radiation rays are formed to the radiation shielding plate. Since the shielding plate is based on a lead glass plate, a sufficient mechanical strength can be obtained with a thinner structure as compared with the conventional plate made of metallic lead. Accordingly, if the shielding plate is disposed on a soft object to be irradiated with radiation rays, the object and the plate itself less deform to obtain a radiation irradiation pattern with distinct edges. (Moriyama, K.)

  5. Plating on difficult-to-plate metals: what's new

    International Nuclear Information System (INIS)

    Wiesner, H.J.

    1980-01-01

    Some of the changes since 1970 in procedures for plating on such materials as titanium, molybdenum, silicon, aluminum, and gallium arsenide are summarized. While basic procedures for plating some of these materials were developed as many as 30 to 40 years ago, changes in the end uses of the plated products have necessitated new plating processes. In some cases, vacuum techniques - such as ion bombardment, ion implantation, and vacuum metallization - have been introduced to improve the adhesion of electrodeposits. In other cases, these techniques have been used to deposit materials upon which electrodeposits are required

  6. Cultural Journalism Publications for Reluctant Readers.

    Science.gov (United States)

    Hatcher, Barbara

    1980-01-01

    Provides a list of cultural journalism publications (based on oral history interviews) written, edited, and produced by students around the country that provide good easy reading for older reluctant readers. (MKM)

  7. Pyramidal approach to license plate segmentation

    Science.gov (United States)

    Postolache, Alexandru; Trecat, Jacques C.

    1996-07-01

    Car identification is a goal in traffic control, transport planning, travel time measurement, managing parking lot traffic and so on. Most car identification algorithms contain a standalone plate segmentation process followed by a plate contents reading. A pyramidal algorithm for license plate segmentation, looking for textured regions, has been developed on a PC based system running Unix. It can be used directly in applications not requiring real time. When input images are relatively small, real-time performance is in fact accomplished by the algorithm. When using large images, porting the algorithm to special digital signal processors can easily lead to preserving real-time performance. Experimental results, for stationary and moving cars in outdoor scenes, showed high accuracy and high scores in detecting the plate. The algorithm also deals with cases where many character strings are present in the image, and not only the one corresponding to the plate. This is done by the means of a constrained texture regions classification.

  8. New technique for number-plate recognition

    Science.gov (United States)

    Guo, Jie; Shi, Peng-Fei

    2001-09-01

    This paper presents an alternative algorithm for number plate recognition. The algorithm consists of three modules. Respectively, they are number plate location module, character segmentation module and character recognition module. Number plate location module extracts the number plate from the detected car image by analyzing the color and the texture properties. Different from most license plate location methods, the algorithm has fewer limits to the car size, the car position in the image and the image background. Character segmentation module applies connected region algorithm both to eliminate noise points and to segment characters. Touching characters and broken characters can be processed correctly. Character recognition module recognizes characters with HHIC (Hierarchical Hybrid Integrated Classifier). The system has been tested with 100 images obtained from crossroad and parking lot, etc, where the cars have different size, position, background and illumination. Successful recognition rate is about 92%. The average processing time is 1.2 second.

  9. Chest wall stabilization and reconstruction: short and long-term results 5 years after the introduction of a new titanium plates system.

    Science.gov (United States)

    De Palma, Angela; Sollitto, Francesco; Loizzi, Domenico; Di Gennaro, Francesco; Scarascia, Daniele; Carlucci, Annalisa; Giudice, Giuseppe; Armenio, Andrea; Ludovico, Rossana; Loizzi, Michele

    2016-03-01

    We report short and long-term results with the dedicated Synthes(®) titanium plates system, introduced 5 years ago, for chest wall stabilization and reconstruction. We retrospectively analyzed (January 2010 to December 2014) 27 consecutive patients (22 males, 5 females; range 16-83 years, median age 60 years), treated with this system: primary [3] and secondary [8] chest wall tumor; flail chest [5]; multiple ribs fractures [5]; sternal dehiscence-diastasis [3]; sternal fracture [1]; sternoclavicular joint dislocation [1]; Poland syndrome [1]. Short-term results were evaluated as: operating time, post-operative morbidity, mortality, hospital stay; long-term results as: survival, plates-related morbidity, spirometric values, chest pain [measured with Verbal Rating Scale (VRS) and SF12 standard V1 questionnaire]. Each patient received from 1 to 10 (median 2) titanium plates/splints; median operating time was 150 min (range: 115-430 min). Post-operative course: 15 patients (55.6%) uneventful, 10 (37%) minor complications, 2 (7.4%) major complications; no post-operative mortality. Median post-operative hospital stay was 13 days (range: 5-129 days). At a median follow-up of 20 months (range: 1-59 months), 21 patients (78%) were alive, 6 (22%) died. Three patients presented long-term plates-related morbidity: plates rupture [2], pin plate dislodgment [1]; two required a second surgical look. One-year from surgery median spirometric values were: FVC 3.31 L (90%), FEV1 2.46 L (78%), DLCO 20.9 mL/mmHg/min (76%). On 21 alive patients, 7 (33.3%) reported no pain (VRS score 0), 10 (47.6%) mild (score 2), 4 (19.1%) moderate (score 4), no-one severe (score >4); 15 (71.5%) reported none or mild, 6 (28.5%) moderate pain influencing quality of life. An optimal chest wall stabilization and reconstruction was achieved with the Synthes(®) titanium plates system, with minimal morbidity, no post-operative mortality, acceptable operating time and post-operative hospital stay. Long

  10. Effect of plate shapes in orifice plate type flowmeters

    International Nuclear Information System (INIS)

    Moeller, S.V.

    1984-01-01

    The study of unusual plate shapes in orifice plate type flowmeters is presented, with a view to providing data for the substitution of the plate with one centered circular orifice in those applications where its use is not possible. For this purpose, six pairs of plates with different forms, with and without chamfered edges, were made and tested in a closed water loop. Results show that, generally, the use of chamfers improves the results and, in the case of perforated and slotlike orificed plates, the narrow-ness of the fluid passage tends to make unnecessary its use. (Author) [pt

  11. Indonesian Landforms and Plate Tectonics

    Directory of Open Access Journals (Sweden)

    Herman Th. Verstappen

    2014-06-01

    Full Text Available DOI: 10.17014/ijog.v5i3.103The horizontal configuration and vertical dimension of the landforms occurring in the tectonically unstable parts of Indonesia were resulted in the first place from plate tectonics. Most of them date from the Quaternary and endogenous forces are ongoing. Three major plates – the northward moving Indo-Australian Plate, the south-eastward moving SE-Asian Plate and the westward moving Pacific Plate - meet at a plate triple-junction situated in the south of New Guinea’s Bird’s Head. The narrow North-Moluccan plate is interposed between the Asia and Pacific. It tapers out northward in the Philippine Mobile Belt and is gradually disappearing. The greatest relief amplitudes occur near the plate boundaries: deep ocean trenches are associated with subduction zones and mountain ranges with collision belts. The landforms of the more stable areas of the plates date back to a more remote past and, where emerged, have a more subdued relief that is in the first place related to the resistance of the rocks to humid tropical weathering Rising mountain ranges and emerging island arcs are subjected to rapid humid-tropical river erosions and mass movements. The erosion products accumulate in adjacent sedimentary basins where their increasing weight causes subsidence by gravity and isostatic compensations. Living and raised coral reefs, volcanoes, and fault scarps are important geomorphic indicators of active plate tectonics. Compartmental faults may strongly affect island arcs stretching perpendicular to the plate movement. This is the case on Java. Transcurrent faults and related pull-apart basins are a leading factor where plates meet at an angle, such as on Sumatra. The most complicated situation exists near the triple-junction and in the Moluccas. Modern research methods, such as GPS measurements of plate movements and absolute dating of volcanic outbursts and raised coral reefs are important tools. The mega-landforms resulting

  12. Plating laboratory

    International Nuclear Information System (INIS)

    Seamster, A.G.; Weitkamp, W.G.

    1984-01-01

    The lead plating of the prototype resonator has been conducted entirely in the plating laboratory at SUNY Stony Brook. Because of the considerable cost and inconvenience in transporting personnel and materials to and from Stony Brook, it is clearly impractical to plate all the resonators there. Furthermore, the high-beta resonator cannot be accommodated at Stony Brook without modifying the set up there. Consequently the authors are constructing a plating lab in-house

  13. How to diagnose any type of TLD Reader?

    International Nuclear Information System (INIS)

    Rodriguez, Manuel Lopez; Garcia, Jose A. Tamayo; Gil, Alex Vergara; Lores, Stefan Gutierrez; Acosta, Andry Romero; Villanueva, Gilberto Alonso

    2013-01-01

    The acquisition of know how of practical experiences obtained in the repair and maintenance of readers TLD RADOS for five years of work and the request by the International Atomic Energy for signing new Research Contracts (CRP), made possible the CRP 13328, in which the specialist is committed in the course of a year, to deliver educational software in order to train personnel associated with the operation of the TLD readers RADOS. Due to the importance of continuous transfer of knowledge for new generations of technicians and specialists who join our laboratories, the idea came when the first interactive CD that grouped 19 videos, divided into three blocks was ready: learning, repair and maintenance; it was suggested to expand the training for any TLD reader. Thus a much more complete than the first version package emerged. 7 cases were subsequently published in an IAEA TECDOC, 1599 were included

  14. Optics for People Stuck in Traffic: License Plates.

    Science.gov (United States)

    Chagnon, Paul

    1995-01-01

    Explains the theory behind the working of Scotchlite, a retrodirective material used for coating automotive license plates, and the Ensure Imaging System that allows law enforcement officers to verify the authenticity of the plate. (JRH)

  15. Plate performance in liquid-liquid extraction

    International Nuclear Information System (INIS)

    Wadkins, R.P.

    1984-01-01

    The relative effectiveness of perforated, nozzle, and burred plates from a capacity and extraction standpoint were studied in a pulsed liquid-liquid extraction system. The experiments were conducted in a 3.8 x 10 -2 m diameter column using a mixture of aluminum nitrate, nitric acid, and uranyl nitrate as the aqueous phase, and tributyl phosphate dissolved in AMSCO 125-90 W as the organic phase. The uranium was extracted from the aqueous phase to the organic phase. A standard cartridge was made for each type of plate and consisted of an assembly of plates spaced 5.08 x 10 -2 m apart. Each plate had 3.2 x 10 -3 m holes spaced on 6.1 x 10 -3 -m centers, and contained 23% free area. 16 references, 4 figures, 1 table

  16. Development of an economic solar heating system with cost efficient flat plate collectors

    Science.gov (United States)

    Eder-Milchgeisser, W.; Burkart, R.

    1980-10-01

    Mass produced flat plate solar collectors were worked into the design of a system for heating a swimming pool and/or providing domestic hot water. The collector characteristics, including physical and mechanical data as well as theoretical energy conversion efficiency, are presented. The collector was tested and service life efficiency was determined. The mounting of the collector, depending on roof type, is explained. Both in service and laboratory test results demonstrate the cost effectiveness of the system. Further improvement of efficiency is envisaged with automatic flow control in the solar collector and hot water circuits.

  17. Peace Pilgrim: A Readers Theatre Approach to Peace Education.

    Science.gov (United States)

    Curran, Joanne M.

    Readers theater is a dramatic art that directs attention to the words of a text. During a performance, a reader (rather than an actor) presents and interprets the work within a narrative context intended by the author. In this project, the text, a collection of the words and writings of a woman known as the Peace Pilgrim, tells the story of her…

  18. Effect of computer-aided detection as a second reader in multidetector-row CT colonography

    International Nuclear Information System (INIS)

    Mang, Thomas; Peloschek, Philipp; Plank, Christina; Maier, Andrea; Weber, Michael; Herold, Christian; Schima, Wolfgang; Graser, Anno; Bogoni, Luca

    2007-01-01

    Our purpose was to assess the effect of computer-aided detection (CAD) on lesion detection as a second reader in computed tomographic colonography, and to compare the influence of CAD on the performance of readers with different levels of expertise. Fifty-two CT colonography patient data-sets (37 patients: 55 endoscopically confirmed polyps ≥0.5 cm, seven cancers; 15 patients: no abnormalities) were retrospectively reviewed by four radiologists (two expert, two nonexpert). After primary data evaluation, a second reading augmented with findings of CAD (polyp-enhanced view, Siemens) was performed. Sensitivities and reading time were calculated for each reader without CAD and supported by CAD findings. The sensitivity of expert readers was 91% each, and of nonexpert readers, 76% and 75%, respectively, for polyp detection. CAD increased the sensitivity of expert readers to 96% (P = 0.25) and 93% (P = 1), and that of nonexpert readers to 91% (P = 0.008) and 95% (P = 0.001), respectively. All four readers diagnosed 100% of cancers, but CAD alone only 43%. CAD increased reading time by 2.1 min (mean). CAD as a second reader significantly improves sensitivity for polyp detection in a high disease prevalence population for nonexpert readers. CAD causes a modest increase in reading time. CAD is of limited value in the detection of cancer. (orig.)

  19. Power Efficient Gurumukhi Unicode Reader Design and Implementation on FPGA

    DEFF Research Database (Denmark)

    Kaur, Amanpreet; Singh, Sunny; Pandey, Bishwajeet

    2017-01-01

    Gurumukhi is found to be the most widely used language of Pakistan, and it is ranked 3rd in Canada, 7th in India and almost 4th most spoken language in U.K. This Unicode Reader is cost effective solution for learning as well as understanding the Punjabi language by the people across the globe .This...... reader helps the user to understand, whether written text is consonants, vowels or digits of Gurumukhi scripts. This paper can also be the solution to the various problems occurred in research of Punjabi natural language processing. Hardware is designed for Gurumukhi Unicode Reader (GUR...

  20. A process for treatment of mixed waste containing chemical plating wastes

    International Nuclear Information System (INIS)

    Anast, K.R.; Dziewinski, J.; Lussiez, G.

    1995-01-01

    The Waste Treatment and Minimization Group at Los Alamos National Laboratory has designed and will be constructing a transportable treatment system to treat low-level radioactive mixed waste generated during plating operations. The chemical and plating waste treatment system is composed of two modules with six submodules, which can be trucked to user sites to treat a wide variety of aqueous waste solutions. The process is designed to remove the hazardous components from the waste stream, generating chemically benign, disposable liquids and solids with low level radioactivity. The chemical and plating waste treatment system is designed as a multifunctional process capable of treating several different types of wastes. At this time, the unit has been the designated treatment process for these wastes: Destruction of free cyanide and metal-cyanide complexes from spent plating solutions; destruction of ammonia in solution from spent plating solutions; reduction of Cr VI to Cr III from spent plating solutions, precipitation, solids separation, and immobilization; heavy metal precipitation from spent plating solutions, solids separation, and immobilization, and acid or base neutralization from unspecified solutions

  1. Readers' Knowledge of Popular Genre

    Science.gov (United States)

    Dixon, Peter; Bortolussi, Marisa

    2009-01-01

    This research examined readers' knowledge of popular genres. Participants wrote short essays on fantasy, science fiction, or romance. The similarities among the essays were measured using latent semantic analysis (LSA) and were then analyzed using multidimensional scaling and cluster analysis. The clusters and scales were interpreted by searching…

  2. Subgrouping Poor Readers on the Basis of Individual Differences in Reading-Related Abilities

    OpenAIRE

    Catts, Hugh W.; Hogan, Tiffany; Fey, Marc E.

    2003-01-01

    The present study investigated the use of the Reading Component Model to subgroup poor readers. A large sample of poor readers was identified in second grade and subgrouped on the basis of relative strengths and weaknesses in word recognition and listening comprehension. Although homogeneous subgroups were not identified, poor readers could be classified into four subgroups that differed significantly in reading-related abilities. Further analyses showed that poor readers' strengths and weakn...

  3. [Comparison of novel infrared heating plates and conventional warm water plates for piglets' creep areas in farrowing pens].

    Science.gov (United States)

    Strauch-Sürken, L; Wendt, M

    2015-01-01

    in winter. IR radiation of heating plates has a positive influence on wound healing after castration and tail docking as well as on umbilical regression. In addition, the lying behavior of sows at farrowing is influenced by the IR radiation. Despite the lower energy consumption of the IR heating plates, the most profitable system has to be determined individually for each farm.

  4. An ion beam tracking system based on a parallel plate avalanche counter

    International Nuclear Information System (INIS)

    Carter, I. P.; Ramachandran, K.; Dasgupta, M.; Hinde, D. J.; Rafiei, R.; Luong, D. H.; Williams, E.; Cook, K. J.; McNeil, S.; Rafferty, D. C.; Harding, A. B.; Muirhead, A. G.; Tunningley, T.

    2013-01-01

    A pair of twin position-sensitive parallel plate avalanche counters have been developed at the Australian National University as a tracking system to aid in the further rejection of unwanted beam particles from a 6.5 T super conducting solenoid separator named SOLEROO. Their function is to track and identify each beam particle passing through the detectors on an event-by-event basis. In-beam studies have been completed and the detectors are in successful operation, demonstrating the tracking capability. A high efficiency 512-pixel wide-angle silicon detector array will then be integrated with the tracking system for nuclear reactions studies of radioactive ions. (authors)

  5. Create Your Plate

    Medline Plus

    Full Text Available ... Plate Share Create Your Plate ! Share: Seven Simple Steps to Create Your Plate It's simple and effective ... foods within each food category. Try these seven steps to get started: Using your dinner plate, put ...

  6. Cognitive Processes in Discourse Comprehension: Passive Processes, Reader-Initiated Processes, and Evolving Mental Representations

    Science.gov (United States)

    van den Broek, Paul; Helder, Anne

    2017-01-01

    As readers move through a text, they engage in various types of processes that, if all goes well, result in a mental representation that captures their interpretation of the text. With each new text segment the reader engages in passive and, at times, reader-initiated processes. These processes are strongly influenced by the readers'…

  7. A wearable force plate system for the continuous measurement of triaxial ground reaction force in biomechanical applications

    International Nuclear Information System (INIS)

    Liu, Tao; Inoue, Yoshio; Shibata, Kyoko

    2010-01-01

    The ambulatory measurement of ground reaction force (GRF) and human motion under free-living conditions is convenient, inexpensive and never restricted to gait analysis in a laboratory environment and is therefore much desired by researchers and clinical doctors in biomedical applications. A wearable force plate system was developed by integrating small triaxial force sensors and three-dimensional (3D) inertial sensors for estimating dynamic triaxial GRF in biomechanical applications. The system, in comparison to existent systems, is characterized by being lightweight, thin and easy-to-wear. A six-axial force sensor (Nitta Co., Japan) was used as a verification measurement device to validate the static accuracy of the developed force plate. To evaluate the precision during dynamic gait measurements, we compared the measurements of the triaxial GRF and the center of pressure (CoP) by using the developed system with the reference measurements made using a stationary force plate and an optical motion analysis system. The root mean square (RMS) differences of the two transverse components (x- and y-axes) and the vertical component (z-axis) of the GRF were 4.3 ± 0.9 N, 6.0 ± 1.3 N and 12.1 ± 1.1 N, respectively, corresponding to 5.1 ± 1.1% and 6.5 ± 1% of the maximum of each transverse component and 1.3 ± 0.2% of the maximum vertical component of GRF. The RMS distance between the two systems' CoP traces was 3.2 ± 0.8 mm, corresponding to 1.2 ± 0.3% of the length of the shoe. Moreover, based on the results of the assessment of the influence of the system on natural gait, we found that gait was almost never affected. Therefore, the wearable system as an alternative device can be a potential solution for measuring CoP and triaxial GRF in non-laboratory environments

  8. analytical bending solution of all clamped isotropic rectangular plate

    African Journals Online (AJOL)

    HP

    PLATE ON WINKLER'S FOUNDATION USING CHARACTERISTIC. ORTHOGONAL ... foundations, storage tanks, swimming pools, floor system of buildings, highways ..... “Energy Methods in Theory of Rectangular Plates. (use of Polynomial ...

  9. How the Relationship between Text and Headings Influences Readers' Memory

    Science.gov (United States)

    Ritchey, Kristin; Schuster, Jonathan; Allen, Jaryn

    2008-01-01

    Two questions regarding signals' influence on memory were examined. First, the relationship between headings and text was manipulated to determine whether headings serve as visual cues, directing readers to recall all subsequent information, or content-specific cues, directing readers to recall only to certain information. Second, distance between…

  10. Breaking the Silence: Toward Improving LGBTQ Representation in Composition Readers

    Science.gov (United States)

    Hudson, John

    2014-01-01

    Lesbian-Gay-Bisexual-Transgender-Queer (LGBTQ) representation in composition readers remains limited and is frequently nonexistent. In addition, the LGBTQ-related materials that do find their way into composition readers are often problematic. In this essay I explain why WPAs and composition teachers should be concerned about LGBTQ representation…

  11. Infographics for Educational Purposes: Their Structure, Properties and Reader Approaches

    Science.gov (United States)

    Yildirim, Serkan

    2016-01-01

    Infographics are one of the new educational environments used to provide information to their readers in a visual way. Infographics are designed to provide information to their readers using various visuals such as texts, pictures, drawings, diagrams, graphs, etc. The use of infographics becomes increasingly widespread both in advertising…

  12. A feedback control system for vibration of magnetostrictive plate subjected to follower force using sinusoidal shear

    Directory of Open Access Journals (Sweden)

    A. Ghorbanpour Arani

    2016-03-01

    Full Text Available In this research, the vibrational behavior of magnetostrictive plate (MsP as a smart component is studied. The plate is subjected to an external follower force and a magnetic field in which the vibration response of MsP has been investigated for both loading combinations. The velocity feedback gain parameter is evaluated to study the effect of magnetic field which is generated by the coil. Sinusoidal shear deformation theory is utilized due to its accuracy of polynomial function with respect to other plate theories. Equations of motion are derived using Hamilton’s principle and solved by differential quadrature method (DQM considering general boundary conditions. The effects of aspect ratio, thickness ratio, follower force and velocity feedback gain are investigated on the frequency response of MsP. Results indicate that magneto-mechanical coupling in MsM helps to control vibrational behaviors of systems such as electro-hydraulic actuator, wireless linear Motors and sensors.

  13. Ultrasonic Testing of NIF Amplifier FAU Top Plates

    International Nuclear Information System (INIS)

    Chinn, D.J.; Huber, R.D.; Haskins, J.J.; Rodriguez, J.A.; Souza, P.R.; Le, T.V.

    2002-01-01

    A key component in the National Ignition Facility (NIF) laser optic system is the amplifier frame assembly unit (FAU). The cast aluminum top plate that supports the FAU is required to withstand loads that would occur during an earthquake with a recurrence period of 1000 years. The stringent seismic requirements placed on the FAU top plate induced a study of the cast aluminum material used in the top plate. Ultrasonic testing was used to aid in characterizing the aluminum material used in the plates. This report documents the work performed using contact ultrasonic testing to characterize the FAU top plate material. The ultrasonic work reported here had 3 objectives: (1) inspect the plate material before cyclic testing conducted at the Pacific Earthquake Engineering Research Center (PEER); (2) determine the overall quality of individual plates; and (3) detect large defects in critical areas of individual plates. Section III, ''Pre-cyclic test inspection'', describes work performed in support of Objective 1. Section IV, ''Ultrasonic field measurements'', describes work performed in support of Objectives 2 and 3

  14. Structure of colloidal sphere-plate mixtures

    International Nuclear Information System (INIS)

    Doshi, N; Cinacchi, G; Van Duijneveldt, J S; Cosgrove, T; Prescott, S W; Grillo, I; Phipps, J; Gittins, D I

    2011-01-01

    In addition to containing spherical pigment particles, coatings usually contain plate-like clay particles. It is thought that these improve the opacity of the paint film by providing an efficient spacing of the pigment particles. This observation is counterintuitive, as suspensions of particles of different shapes and sizes tend to phase separate on increase of concentration. In order to clarify this matter a model colloidal system is studied here, with a sphere-plate diameter ratio similar to that found in paints. For dilute suspensions, small angle neutron scattering revealed that the addition of plates leads to enhanced density fluctuations of the spheres, in agreement with new theoretical predictions. On increasing the total colloid concentration the plates and spheres phase separate due to the disparity in their shape. This is in agreement with previous theoretical and experimental work on colloidal sphere-plate mixtures, where one particle acts as a depleting agent. The fact that no large scale phase separation is observed in coatings is ascribed to dynamic arrest in intimately mixed, or possibly micro-phase separated structures, at elevated concentration.

  15. Structure of colloidal sphere-plate mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Doshi, N; Cinacchi, G; Van Duijneveldt, J S; Cosgrove, T; Prescott, S W [School of Chemistry, University of Bristol, Bristol BS8 1TS (United Kingdom); Grillo, I [Institut Laue-Langevin, 6 rue Jules Horowitz BP 156, 38042 Grenoble Cedex 9 (France); Phipps, J [Imerys Minerals Ltd, Par Moor Centre, Par Moor Road, Par, Cornwall PL24 2SQ (United Kingdom); Gittins, D I, E-mail: Giorgio.Cinacchi@bristol.ac.uk, E-mail: J.S.van-Duijneveldt@bristol.ac.uk [Imerys Performance and Filtration Minerals Ltd, 130 Castilian Drive, Goleta, CA 93117 (United States)

    2011-05-18

    In addition to containing spherical pigment particles, coatings usually contain plate-like clay particles. It is thought that these improve the opacity of the paint film by providing an efficient spacing of the pigment particles. This observation is counterintuitive, as suspensions of particles of different shapes and sizes tend to phase separate on increase of concentration. In order to clarify this matter a model colloidal system is studied here, with a sphere-plate diameter ratio similar to that found in paints. For dilute suspensions, small angle neutron scattering revealed that the addition of plates leads to enhanced density fluctuations of the spheres, in agreement with new theoretical predictions. On increasing the total colloid concentration the plates and spheres phase separate due to the disparity in their shape. This is in agreement with previous theoretical and experimental work on colloidal sphere-plate mixtures, where one particle acts as a depleting agent. The fact that no large scale phase separation is observed in coatings is ascribed to dynamic arrest in intimately mixed, or possibly micro-phase separated structures, at elevated concentration.

  16. Prereader to beginning reader: changes induced by reading acquisition in print and speech brain networks.

    Science.gov (United States)

    Chyl, Katarzyna; Kossowski, Bartosz; Dębska, Agnieszka; Łuniewska, Magdalena; Banaszkiewicz, Anna; Żelechowska, Agata; Frost, Stephen J; Mencl, William Einar; Wypych, Marek; Marchewka, Artur; Pugh, Kenneth R; Jednoróg, Katarzyna

    2018-01-01

    Literacy acquisition is a demanding process that induces significant changes in the brain, especially in the spoken and written language networks. Nevertheless, large-scale paediatric fMRI studies are still limited. We analyzed fMRI data to show how individual differences in reading performance correlate with brain activation for speech and print in 111 children attending kindergarten or first grade and examined group differences between a matched subset of emergent-readers and prereaders. Across the entire cohort, individual differences analysis revealed that reading skill was positively correlated with the magnitude of activation difference between words and symbol strings in left superior temporal, inferior frontal and fusiform gyri. Group comparisons of the matched subset of pre- and emergent-readers showed higher activity for emergent-readers in left inferior frontal, precentral, and postcentral gyri. Individual differences in activation for natural versus vocoded speech were also positively correlated with reading skill, primarily in the left temporal cortex. However, in contrast to studies on adult illiterates, group comparisons revealed higher activity in prereaders compared to readers in the frontal lobes. Print-speech coactivation was observed only in readers and individual differences analyses revealed a positive correlation between convergence and reading skill in the left superior temporal sulcus. These results emphasise that a child's brain undergoes several modifications to both visual and oral language systems in the process of learning to read. They also suggest that print-speech convergence is a hallmark of acquiring literacy. © 2017 Association for Child and Adolescent Mental Health.

  17. Reader practice in mammography screen reporting in Australia

    International Nuclear Information System (INIS)

    Reed, W.; Poulos, A.; Brennan, P.

    2009-01-01

    Full text: Reader variability is a problem in mammography image reporting and compromises the efficacy of screening programmes. The purpose of this exploratory study was to survey reader practice in reporting screening mammograms in Australia to identify aspects of practice that warrant further investigation. Mammography reporting practice and influences on concentration and attention were investigated by using an original questionnaire distributed to screen readers in Australia. A response rate of 71% (83 out of 117) was achieved. Demographic data indicated that the majority of readers were over 46 years of age (73%), have been reporting on screening mammograms for over 10 years (61%), take less than 1 min to report upon a screening mammogram examination (66%), report up to 200 examinations in a single session (83%) and take up to 2 h to report one session (61%). A majority report on more than 5000 examinations annually (66%); 93% of participants regard their search strategy as systematic, 87% agreed that their concentration can vary throughout a session, 64% agreed that the relatively low number of positives can lead to lapses in concentration and attention and almost all (94%) participants agreed that methods to maximise concentration should be explored. Participants identified a range of influences on concentration within their working environment including volume of images reported in one session, image types and aspects of the physical environment. This study has provided important evidence of the need to investigate adverse influences on concentration during mammography screen reporting

  18. Reader error during CT colonography: causes and implications for training

    International Nuclear Information System (INIS)

    Slater, Andrew; Tam, Emily; Gartner, Louise; Scarth, Julia; Peiris, Chand; Gupta, Arun; Marshall, Michele; Burling, David; Taylor, Stuart A.; Halligan, Steve

    2006-01-01

    This study investigated the variability in baseline computed tomography colonography (CTC) performance using untrained readers by documenting sources of error to guide future training requirements. Twenty CTC endoscopically validated data sets containing 32 polyps were consensus read by three unblinded radiologists experienced in CTC, creating a reference standard. Six readers without prior CTC training [four residents and two board-certified subspecialty gastrointestinal (GI) radiologists] read the 20 cases. Readers drew a region of interest (ROI) around every area they considered a potential colonic lesion, even if subsequently dismissed, before creating a final report. Using this final report, reader ROIs were classified as true positive detections, true negatives correctly dismissed, true detections incorrectly dismissed (i.e., classification error), or perceptual errors. Detection of polyps 1-5 mm, 6-9 mm, and ≥10 mm ranged from 7.1% to 28.6%, 16.7% to 41.7%, and 16.7% to 83.3%, respectively. There was no significant difference between polyp detection or false positives for the GI radiologists compared with residents (p=0.67, p=0.4 respectively). Most missed polyps were due to failure of detection rather than characterization (range 82-95%). Untrained reader performance is variable but generally poor. Most missed polyps are due perceptual error rather than characterization, suggesting basic training should focus heavily on lesion detection. (orig.)

  19. An Expert System to Analyze Homogeneity in Fuel Element Plates for Research Reactors

    International Nuclear Information System (INIS)

    Tolosa, S.C.; Marajofsky, A.

    2004-01-01

    In the manufacturing control of Fuel Element Plates for Research Reactors, one of the problems to be addressed is how to determine the U-density homogeneity in a fuel plate and how to obtain qualitative and quantitative information in order to establish acceptance or rejection criteria for such, as well as carrying out the quality follow-up. This paper is aimed at developing computing software which implements an Unsupervised Competitive Learning Neural Network for the acknowledgment of regions belonging to a digitalized gray scale image. This program is applied to x-ray images. These images are generated when the x-ray beams go through a fuel plate of approximately 60 cm x 8 cm x 0.1 cm thick. A Nuclear Fuel Element for Research Reactors usually consists of 18 to 22 of these plates, positioned in parallel, in an arrangement of 8 x 7 cm. Carrying out the inspection of the digitalized x-ray image, the neural network detects regions with different luminous densities corresponding to U-densities in the fuel plate. This is used in quality control to detect failures and verify acceptance criteria depending on the homogeneity of the plate. This modality of inspection is important as it allows the performance of non-destructive measurements and the automatic generation of the map of U-relative densities of the fuel plate

  20. An expert system to analyze homogeneity in fuel element plates for research reactors

    International Nuclear Information System (INIS)

    Cativa Tolosa, Sebastian; Marajofsky, Adolfo

    2004-01-01

    In the manufacturing control of Fuel Element Plates for Research Reactors, one of the problems to be addressed is how to determine the U-density homogeneity in a fuel plate and how to obtain qualitative and quantitative information in order to establish acceptance or rejection criteria for such, as well as carrying out the quality follow-up.This paper is aimed at developing computing software which implements an Unsupervised Competitive Learning Neural Network for the acknowledgment of regions belonging to a digitalized gray scale image. This program is applied to X-ray images. These images are generated when the X-ray beams go through a fuel plate of approximately 60 cm x 8 cm x 0.1 cm thick. A Nuclear Fuel Element for Research Reactors usually consists of 18 to 22 of these plates, positioned in parallel, in an arrangement of 8 x 7 cm. Carrying out the inspection of the digitalized X-ray image, the neural network detects regions with different luminous densities corresponding to U-densities in the fuel plate. This is used in quality control to detect failures and verify acceptance criteria depending on the homogeneity of the plate. This modality of inspection is important as it allows the performance of non-destructive measurements and the automatic generation of the map of U-relative densities of the fuel plate. (author)

  1. Management of pediatric mandibular fractures using bioresorbable plating system - Efficacy, stability, and clinical outcomes: Our experiences and literature review.

    Science.gov (United States)

    Singh, Mahinder; Singh, R K; Passi, Deepak; Aggarwal, Mohit; Kaur, Guneet

    2016-01-01

    The purpose of this study was to determine the efficacy and stability of the biodegradable fixation system for treatment of mandible fractures in pediatric patients by measuring the bite force. Sixty pediatric patients with mandibular fractures (36 males, 24 females) were included in this study. The 2.5-mm resorbable plates were adapted along Champy's line of ideal osteosynthesis and secured with four 2.5 mm diameter monocortical resorbable screws, 8 mm in length. All patients were followed for 10 months. Clinical parameters, such as soft tissue infection, nonunion, malunion, implant exposure, malocclusion, nerve injury, and bite force for stability, were prospectively assessed. Adequate fixation and primary bone healing was achieved in 100% of the cases. Six minor complications (10%) were observed: 2 soft tissue infections (3%), 1 plate dehiscence (2%), 1 malocclusion (2%), and 2 paresthesia (3%). 2.5-mm resorbable plating system along Champy's line of ideal osteosynthesis is a good treatment modality for mandible fractures in pediatric patients.

  2. Method for regeneration of electroless nickel plating solution

    Science.gov (United States)

    Eisenmann, E.T.

    1997-03-11

    An electroless nickel(EN)/hypophosphite plating bath is provided employing acetic acid/acetate as a buffer and which is, as a result, capable of perpetual regeneration while avoiding the production of hazardous waste. A regeneration process is provided to process the spent EN plating bath solution. A concentrated starter and replenishment solution is provided for ease of operation of the plating bath. The regeneration process employs a chelating ion exchange system to remove nickel cations from spent EN plating solution. Phosphites are then removed from the solution by precipitation. The nickel cations are removed from the ion exchange system by elution with hypophosphorus acid and the nickel concentration of the eluate adjusted by addition of nickel salt. The treated solution and adjusted eluate are combined, stabilizer added, and the volume of resulting solution reduced by evaporation to form the bath starter and replenishing solution. 1 fig.

  3. Method for regeneration of electroless nickel plating solution

    Science.gov (United States)

    Eisenmann, Erhard T.

    1997-01-01

    An electroless nickel(EN)/hypophosphite plating bath is provided employing acetic acid/acetate as a buffer and which is, as a result, capable of perpetual regeneration while avoiding the production of hazardous waste. A regeneration process is provided to process the spent EN plating bath solution. A concentrated starter and replenishment solution is provided for ease of operation of the plating bath. The regeneration process employs a chelating ion exchange system to remove nickel cations from spent EN plating solution. Phosphites are then removed from the solution by precipitation. The nickel cations are removed from the ion exchange system by elution with hypophosphorous acid and the nickel concentration of the eluate adjusted by addition of nickel salt. The treated solution and adjusted eluate are combined, stabilizer added, and the volume of resulting solution reduced by evaporation to form the bath starter and replenishing solution.

  4. Flow-induced plastic collapse of stacked fuel plates

    Energy Technology Data Exchange (ETDEWEB)

    Davis, D C; Scarton, H A

    1985-03-01

    Flow-induced plastic collapse of stacked fuel plate assemblies was first noted in experimental reactors such as the ORNL High Flux Reactor Assembly and the Engineering Test Reactor (ETR). The ETR assembly is a stack of 19 thin flat rectangular fuel plates separated by narrow channels through which a coolant flows to remove the heat generated by fission of the fuel within the plates. The uranium alloyed plates have been noted to buckle laterally and plastically collapse at the system design coolant flow rate of 10.7 m/s, thus restricting the coolant flow through adjacent channels. A methodology and criterion are developed for predicting the plastic collapse of ETR fuel plates. The criterion is compared to some experimental results and the Miller critical velocity theory.

  5. Add-on unidirectional elastic metamaterial plate cloak

    Science.gov (United States)

    Lee, Min Kyung; Kim, Yoon Young

    2016-02-01

    Metamaterial cloaks control the propagation of waves to make an object invisible or insensible. To manipulate elastic waves in space, a metamaterial cloak is typically embedded in a base system that includes or surrounds a target object. The embedding is undesirable because it structurally weakens or permanently alters the base system. In this study, we propose a new add-on metamaterial elastic cloak that can be placed over and mechanically coupled with a base structure without embedding. We designed an add-on type annular metamaterial plate cloak through conformal mapping, fabricated it and performed cloaking experiments in a thin-plate with a hole. Experiments were performed in a thin plate by using the lowest symmetric Lamb wave centered at 100 kHz. As a means to check the cloaking performance of the add-on elastic plate cloak, possibly as a temporary stress reliever or a so-called “stress bandage”, the degree of stress concentration mitigation and the recovery from the perturbed wave field due to a hole were investigated.

  6. Bimodal Reading: Benefits of a Talking Computer for Average and Less Skilled Readers.

    Science.gov (United States)

    Montali, Julie; Lewandowski, Lawrence

    1996-01-01

    Eighteen average readers and 18 less-skilled readers (grades 8 and 9) were presented with social studies and science passages via a computer either visually (on screen), auditorily (read by digitized voice), or bimodally (on screen, highlighted while being voiced). Less-skilled readers demonstrated comprehension in the bimodal condition equivalent…

  7. The Narratological Style and the Reader of Evelyn Waugh’s Early Satires

    Directory of Open Access Journals (Sweden)

    Roksana Zgierska

    2017-06-01

    Full Text Available The article deals with the role of the implied reader in Evelyn Waugh’s novels. An attempt will be made to define who the implied reader is and what is his position and role in fictional realm. By analysing narrative strategies and techniques within a selection of Waugh’s works, I attempt to discuss the changing relationship between author/narrator and the implied reader. I try to point that within Evelyn Waugh’s writing one can observe a simultaneous evolution of the narrator voice and the role ascribed to the implied reader. What is more, I discuss the limits of interpretation. I try to present and analyse how both the author/narrator and the text can impose limitations on the implied reader allowing him to move freely, however, within a set frame. Intertextuality is one of the focal points of the article, as I try to propose that the use of specific intertextual references in several different novels enhances the reader’s understanding of  Waugh’s fictional world. An attempt is made to prove that through analysis of different levels of understanding intertextual relation the reader takes on himself a role of creator. Furthermore, I draw attention to the places of indeterminacy. In this discussion I include both structures of indeterminacy proposed by Roman Ingarden i.e. blanks and negations, as both are needed not only to establish the interaction that takes place between text and the implied reader, but also to try to regulate such relation. An attempt will be made to explain how important filling the gaps within the text is and how completing the blanks affects the reader and the process of reading as such.

  8. Concentration of solar radiation by white painted transparent plates.

    Science.gov (United States)

    Smestad, G; Hamill, P

    1982-04-01

    A simple flat-plate solar concentrator is described in this paper. The device is composed of a white painted transparent plate with a photovoltaic cell fixed to an unpainted area on the bottom of the plate. Light scattering off the white material is either lost or directed to the solar cell. Experimental concentrations of up to 1.9 times the incident solar flux have been achieved using white clays. These values are close to those predicted by theory for the experimental parameters investigated. A theory of the device operation is developed. Using this theory suggestions are made for optimizing the concentrator system. For reasonable choices of cell and plate size and reflectivities of 80% concentrations of over 2x are possible. The concentrator has the advantage over other systems in that the concentration is independent of incidence angle and the concentrator is easy to produce. The device needs no tracking system and will concentrate on a cloudy day.

  9. Radiation-hard ceramic Resistive Plate Chambers for forward TOF and T0 systems

    Energy Technology Data Exchange (ETDEWEB)

    Akindinov, A., E-mail: Alexander.Akindinov@cern.ch [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Dreyer, J.; Fan, X.; Kämpfer, B. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Kiselev, S. [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Kotte, R.; Garcia, A. Laso [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Malkevich, D. [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Naumann, L. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Nedosekin, A.; Plotnikov, V. [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Stach, D. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Sultanov, R.; Voloshin, K. [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation)

    2017-02-11

    Resistive Plate Chambers with ceramic electrodes are the main candidates for a use in precise multi-channel timing systems operating in high-radiation conditions. We report the latest R&D results on these detectors aimed to meet the requirements of the forward T0 counter at the CBM experiment. RPC design, gas mixture, limits on the bulk resistivity of ceramic electrodes, efficiency, time resolution, counting rate capabilities and ageing test results are presented.

  10. Cooled electronic system with liquid-cooled cold plate and thermal spreader coupled to electronic component

    Science.gov (United States)

    Chainer, Timothy J.; Graybill, David P.; Iyengar, Madhusudan K.; Kamath, Vinod; Kochuparambil, Bejoy J.; Schmidt, Roger R.; Steinke, Mark E.

    2018-03-27

    Apparatus and method are provided for facilitating cooling of an electronic component. The apparatus includes a liquid-cooled cold plate and a thermal spreader associated with the cold plate. The cold plate includes multiple coolant-carrying channel sections extending within the cold plate, and a thermal conduction surface with a larger surface area than a surface area of the component to be cooled. The thermal spreader includes one or more heat pipes including multiple heat pipe sections. One or more heat pipe sections are partially aligned to a first region of the cold plate, that is, where aligned to the surface to be cooled, and partially aligned to a second region of the cold plate, which is outside the first region. The one or more heat pipes facilitate distribution of heat from the electronic component to coolant-carrying channel sections of the cold plate located in the second region of the cold plate.

  11. International study on inter-reader variability for circulating tumor cells in breast cancer

    NARCIS (Netherlands)

    Ignatiadis, Michail; Riethdorf, Sabine; Bidard, François-Clement; Vaucher, Isabelle; Khazour, Mustapha; Rothe, Francoise; Metallo, Jessica; Rouas, Ghizlane; Payne, Rachel E.; Coombes, Raoul Charles; Teufel, Ingrid; Andergassen, Ulrich; Apostolaki, Stella; Politaki, Eleni; Mavroudis, Dimitris; Bessi, Silvia; Pestrin, Martta; di Leo, Angelo; Campion, Michael; Reinholz, Monica; Perez, Edith; Piccart, Martine; Borgen, Elin; Naume, Bjorn; Jimenez, Jose; Aura, Claudia Monica; Zorzino, Laura; Cassatella, Maria Cristina; Sandri, Maria Teresa; Mostert, Bianca; Sleijfer, Stefan; Kraan, Jaco; Janni, Wolfgang; Fehm, Tanja; Rack, Brigitte; Terstappen, Leonardus Wendelinus Mathias Marie; Repollet, Madeline; Pierga, Jean-Yves; Miller, Craig; Sotiriou, Christos; Michiels, Stefan; Pantel, Klaus

    2014-01-01

    IntroductionCirculating tumor cells (CTCs) have been studied in breast cancer with the CellSearch® system. Given the low CTC counts in non-metastatic breast cancer, it is important to evaluate the inter-reader agreement. MethodsCellSearch® images (N = 272) of either CTCs or white blood cells or

  12. Chaotic synchronization of vibrations of a coupled mechanical system consisting of a plate and beams

    Directory of Open Access Journals (Sweden)

    J. Awrejcewicz

    Full Text Available In this paper mathematical model of a mechanical system consisting of a plate and either one or two beams is derived. Obtained PDEs are reduced to ODEs, and then studied mainly using the fast Fourier and wavelet transforms. A few examples of the chaotic synchronizations are illustrated and discussed.

  13. Plate tectonics and planetary habitability: current status and future challenges.

    Science.gov (United States)

    Korenaga, Jun

    2012-07-01

    Plate tectonics is one of the major factors affecting the potential habitability of a terrestrial planet. The physics of plate tectonics is, however, still far from being complete, leading to considerable uncertainty when discussing planetary habitability. Here, I summarize recent developments on the evolution of plate tectonics on Earth, which suggest a radically new view on Earth dynamics: convection in the mantle has been speeding up despite its secular cooling, and the operation of plate tectonics has been facilitated throughout Earth's history by the gradual subduction of water into an initially dry mantle. The role of plate tectonics in planetary habitability through its influence on atmospheric evolution is still difficult to quantify, and, to this end, it will be vital to better understand a coupled core-mantle-atmosphere system in the context of solar system evolution. © 2012 New York Academy of Sciences.

  14. Social  reading - the reader on digital margins

    Directory of Open Access Journals (Sweden)

    Ivona Despot

    2016-12-01

    Full Text Available Electronic books enrich the reading experience through a range of possibilities digital technology offers, such as commenting or adding content at the margin space, marking interesting chapters and sharing the content with other readers. The phenomenon of social reading emerges with the influence of technology in the sphere of reading books and creates interactions for readers with the content and other readers. The great potential of enriching the reading experience is visible in the digital platforms for social reading, where the interaction and the creation of new content encourages the development of new way of reading and creativity. These activities may contribute to better understanding of the text. This enhances the communication about the text thus revitalizing the content and moves the reading itself from private to public sphere. This paper will show how are the activities in the digital margins transformed into a good indicator of the reading behavior, as well as the importance and usefulness of such for publishers to create new publishing products and services.

  15. A Dual-Route Perspective on Eye Movements of Dyslexic Readers

    Science.gov (United States)

    Hawelka, Stefan; Gagl, Benjamin; Wimmer, Heinz

    2010-01-01

    This study assessed eye movement abnormalities of adolescent dyslexic readers and interpreted the findings by linking the dual-route model of single word reading with the E-Z Reader model of eye movement control during silent sentence reading. A dysfunction of the lexical route was assumed to account for a reduced number of words which received…

  16. Validation of a high-throughput fermentation system based on online monitoring of biomass and fluorescence in continuously shaken microtiter plates

    Directory of Open Access Journals (Sweden)

    Kensy Frank

    2009-06-01

    Full Text Available Abstract Background An advanced version of a recently reported high-throughput fermentation system with online measurement, called BioLector, and its validation is presented. The technology combines high-throughput screening and high-information content by applying online monitoring of scattered light and fluorescence intensities in continuously shaken microtiter plates. Various examples in calibration of the optical measurements, clone and media screening and promoter characterization are given. Results Bacterial and yeast biomass concentrations of up to 50 g/L cell dry weight could be linearly correlated to scattered light intensities. In media screening, the BioLector could clearly demonstrate its potential for detecting different biomass and product yields and deducing specific growth rates for quantitatively evaluating media and nutrients. Growth inhibition due to inappropriate buffer conditions could be detected by reduced growth rates and a temporary increase in NADH fluorescence. GFP served very well as reporter protein for investigating the promoter regulation under different carbon sources in yeast strains. A clone screening of 90 different GFP-expressing Hansenula polymorpha clones depicted the broad distribution of growth behavior and an even stronger distribution in GFP expression. The importance of mass transfer conditions could be demonstrated by varying filling volumes of an E. coli culture in 96 well MTP. The different filling volumes cause a deviation in the culture growth and acidification both monitored via scattered light intensities and the fluorescence of a pH indicator, respectively. Conclusion The BioLector technology is a very useful tool to perform quantitative microfermentations under engineered reaction conditions. With this technique, specific yields and rates can be directly deduced from online biomass and product concentrations, which is superior to existing technologies such as microplate readers or optode

  17. 21 CFR 866.2850 - Automated zone reader.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2850 Automated zone reader... surface of certain culture media used in disc-agar diffusion antimicrobial susceptibility tests. The...

  18. Use of the Ion PGM and the GeneReader NGS Systems in Daily Routine Practice for Advanced Lung Adenocarcinoma Patients: A Practical Point of View Reporting a Comparative Study and Assessment of 90 Patients

    Directory of Open Access Journals (Sweden)

    Simon Heeke

    2018-03-01

    Full Text Available Background: With the integration of various targeted therapies into the clinical management of patients with advanced lung adenocarcinoma, next-generation sequencing (NGS has become the technology of choice and has led to an increase in simultaneously interrogated genes. However, the broader adoption of NGS for routine clinical practice is still hampered by sophisticated workflows, complex bioinformatics analysis and medical interpretation. Therefore, the performance of the novel QIAGEN GeneReader NGS system was compared to an in-house ISO-15189 certified Ion PGM NGS platform. Methods: Clinical samples from 90 patients (60 Retrospectively and 30 Prospectively with lung adenocarcinoma were sequenced with both systems. Mutations were analyzed and EGFR, KRAS, BRAF, NRAS, ALK, PIK3CA and ERBB2 genes were compared and sampling time and suitability for clinical testing were assessed. Results: Both sequencing systems showed perfect concordance for the overlapping genes. Correlation of allele frequency was r2 = 0.93 for the retrospective patients and r2 = 0.81 for the prospective patients. Hands-on time and total run time were shorter using the PGM system, while the GeneReader platform provided good traceability and up-to-date interpretation of the results. Conclusion: We demonstrated the suitability of the GeneReader NGS system in routine practice in a clinical pathology laboratory setting.

  19. Locking screw-plate interface stability in carbon-fibre reinforced polyetheretherketone proximal humerus plates.

    Science.gov (United States)

    Hak, David J; Fader, Ryan; Baldini, Todd; Chadayammuri, Vivek B S

    2017-09-01

    Carbon-fibre reinforced polyetheretherketone (CFR-PEEK) plates have recently been introduced for proximal humerus fracture treatment. The purpose of this study was to compare the locking screw-plate interface stability in CFR-PEEK versus stainless steel (SS) proximal humerus plates. Locking screw mechanical stability was evaluated independently in proximal and shaft plate holes. Stiffness and load to failure were tested for three conditions: (1) on-axis locking screw insertion in CFR-PEEK versus SS plates, (2) on-axis locking screw insertion, removal, and reinsertion in CFR-PEEK plates, and (3) 10-degree off-axis locking screw insertion in CFR-PEEK plates. Cantilever bending at a rate of 1 mm/minute was produced by an Instron machine and load-displacement data recorded. Shaft locking screw load to failure was significantly greater in CFR-PEEK plates compared to SS plates (746.4 ± 89.7 N versus 596.5 ± 32.6 N, p PEEK plates (p PEEK plates. The mechanical stability of locking screws in CFR-PEEK plates is comparable or superior to locking screws in SS plates.

  20. CT colonography: effect of experience and training on reader performance

    International Nuclear Information System (INIS)

    Taylor, Stuart A.; Burling, David; Morley, Simon; Bartram, Clive I.; Halligan, Steve; Bassett, Paul; Atkin, Wendy

    2004-01-01

    The purpose of this paper was to investigate the effect of radiologist experience and increasing exposure to CT colonography on reader performance. Three radiologists of differing general experience (consultant, research fellow, trainee) independently analysed 100 CT colonographic datasets. Readers had no prior experience of CT colonography and received feedback and training after the first 50 cases from an independent experienced radiologist. Diagnostic performance and reporting times were compared for the first and second 50 datasets and compared with the results of a radiologist experienced in CT colonography. Before training only the consultant reader achieved statistical equivalence with the reference standard for detection of larger polyps. After training, detection rates ranged between 25 and 58% for larger polyps. Only the trainee significantly improved after training (P=0.007), with performance of other readers unchanged or even worse. Reporting times following training were reduced significantly for the consultant and fellow (P<0.001 and P=0.03, respectively), but increased for the trainee (P<0.001). In comparison to the consultant reader, the odds of detection of larger polyps was 0.36 (CI 0.16, 0.82) for the fellow and 0.36 (CI 0.14, 0.91) for the trainee. There is considerable variation in the ability to report CT colonography. Prior experience in gastrointestinal radiology is a distinct advantage. Competence cannot be assumed even after directed training via a database of 50 cases. (orig.)

  1. Follow the Reader: An Effective Strategy to Support Students Reading More Complex Text

    Science.gov (United States)

    Klvacek, Michelle L.; Monroe, Eula Ewing; Wilcox, Brad; Hall-Kenyon, Kendra M.; Morrison, Timothy G.

    2017-01-01

    This article describes how one second-grade teacher implemented Follow the Reader, her term for dyad reading. Common Core expects students to read increasingly complex texts. Teachers can implement dyad reading with this end in mind. It is a modified version of the neurological impress method in which a lead reader and an assisted reader sit side…

  2. Blind Braille readers mislocate tactile stimuli.

    Science.gov (United States)

    Sterr, Annette; Green, Lisa; Elbert, Thomas

    2003-05-01

    In a previous experiment, we observed that blind Braille readers produce errors when asked to identify on which finger of one hand a light tactile stimulus had occurred. With the present study, we aimed to specify the characteristics of this perceptual error in blind and sighted participants. The experiment confirmed that blind Braille readers mislocalised tactile stimuli more often than sighted controls, and that the localisation errors occurred significantly more often at the right reading hand than at the non-reading hand. Most importantly, we discovered that the reading fingers showed the smallest error frequency, but the highest rate of stimulus attribution. The dissociation of perceiving and locating tactile stimuli in the blind suggests altered tactile information processing. Neuroplasticity, changes in tactile attention mechanisms as well as the idea that blind persons may employ different strategies for tactile exploration and object localisation are discussed as possible explanations for the results obtained.

  3. Robot Arm with Tendon Connector Plate and Linear Actuator

    Science.gov (United States)

    Ihrke, Chris A. (Inventor); Diftler, Myron A. (Inventor); Bridgwater, Lyndon (Inventor); Nguyen, Vienny (Inventor); Millerman, Alexander (Inventor)

    2014-01-01

    A robotic system includes a tendon-driven end effector, a linear actuator, a flexible tendon, and a plate assembly. The linear actuator assembly has a servo motor and a drive mechanism, the latter of which translates linearly with respect to a drive axis of the servo motor in response to output torque from the servo motor. The tendon connects to the end effector and drive mechanism. The plate assembly is disposed between the linear actuator assembly and the tendon-driven end effector and includes first and second plates. The first plate has a first side that defines a boss with a center opening. The second plate defines an accurate through-slot having tendon guide channels. The first plate defines a through passage for the tendon between the center opening and a second side of the first plate. A looped end of the flexible tendon is received within the tendon guide channels.

  4. Extended Plate and Beam Wall System: Concept Investigation and Initial Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Wiehagen, J. [Partnership for Home Innovation, Upper Marlboro, MD (United States); Kochkin, V. [Partnership for Home Innovation, Upper Marlboro, MD (United States)

    2015-08-01

    A new and innovative High-R wall design, referred to as the Extended Plate & Beam (EP&B), is under development. The EP&B system uniquely integrates foam sheathing insulation with wall framing such that wood structural panels are installed exterior of the foam sheathing, enabling the use of standard practices for installation of drainage plane, windows and doors, claddings, cavity insulation, and the standard exterior foam sheathing installation approach prone to damage of the foam during transportation of prefabricated wall panels. As part of the ongoing work, the EP&B wall system concept has undergone structural verification testing and has been positively vetted by a group of industry stakeholders. Having passed these initial milestone markers, the advanced wall system design has been analyzed to assess cost implications relative to other advanced wall systems, undergone design assessment to develop construction details, and has been evaluated to develop representative prescriptive requirements for the building code. This report summarizes the assessment steps conducted to-date and provides details of the concept development.

  5. Investigation of vertebral ''end plate sclerosis''

    International Nuclear Information System (INIS)

    Lee, S.W.; Mathie, A.G.; Jackson, J.E.; Hughes, S.P.F.

    2001-01-01

    To evaluate the association between vertebral ''end plate sclerosis'' and neck pain. A retrospective study was carried out of lateral cervical spine radiographs with a Picture Archive and Communication System (PACS). Two hundred patients' files were randomly assessed, comprising four equal groups, A to D. The mean ages of the patients were 62±7.4 years, 61±7.5 years, 40±5.6 years and 23±5.6 years respectively. In group A, all patients had symptoms of neck pain and a radiographic diagnosis of ''end plate sclerosis'' of the cervical spine. In groups B to D, asymptomatic patients were recruited and their age groups were 50-69, 30-49 and 10-29 years respectively. Using the PACS, the radiographic density and the sagittal diameter, thickness and area of the end plates at the C5 level were measured. Results and conclusions: No significant differences were found in the radiographic density of the end plates either between the symptomatic and asymptomatic groups (groups A and B), or between different age groups (groups B, C and D). A significant increase in end plate area and thickness was found, however, in both group B (P<0.005) and group C (P<0.01) in comparison with group D. This indicates that the extent of end plate sclerosis increases with age. Our results suggest that the radiographic density of cervical vertebral end plates correlates neither with neck pain nor with increasing age. The radiological sign of ''end plate sclerosis'' may be over-reported, further limiting its value in the assessment of patients with cervical spondylosis. (orig.)

  6. An aluminium evaporation source for ion plating

    International Nuclear Information System (INIS)

    Walley, P.A.; Cross, K.B.

    1977-01-01

    Ion plating with aluminium is becoming increasingly accepted as a method of anti-corrosion surface passivation, the usual requirements being for a layer between 12 and 50 microns in thickness, (0.0005 to 0.002). The evaporation system described here offers a number of advantages over high power electron beam sources when used for aluminium ion plating. The source consists of a resistively heated, specially shaped, boron nitride-titanium diboride boat and a metering feed system. Its main features are small physical size, soft vacuum compatibility, low power consumption and metered evaporation output. (author)

  7. A nonlinear plate control without linearization

    Directory of Open Access Journals (Sweden)

    Yildirim Kenan

    2017-03-01

    Full Text Available In this paper, an optimal vibration control problem for a nonlinear plate is considered. In order to obtain the optimal control function, wellposedness and controllability of the nonlinear system is investigated. The performance index functional of the system, to be minimized by minimum level of control, is chosen as the sum of the quadratic 10 functional of the displacement. The velocity of the plate and quadratic functional of the control function is added to the performance index functional as a penalty term. By using a maximum principle, the nonlinear control problem is transformed to solving a system of partial differential equations including state and adjoint variables linked by initial-boundary-terminal conditions. Hence, it is shown that optimal control of the nonlinear systems can be obtained without linearization of the nonlinear term and optimal control function can be obtained analytically for nonlinear systems without linearization.

  8. Design and trial evaluation of the user interface for MusicReader

    NARCIS (Netherlands)

    Leoné, Marco; van Dijk, Elisabeth M.A.G.; van Beijnum, Bernhard J.F.

    2008-01-01

    This paper describes the design and trial results of MusicReader, a networked application realizing sheet music related services for the support of ensemble and orchestra rehearsals and performances. To this end, MusicReader presents sheet music on computer screens and supports annotations, sheet

  9. Techno-Literacy Practices of Emergent Readers

    Directory of Open Access Journals (Sweden)

    Razeale G. Fernandez

    2015-12-01

    Full Text Available – This research explored the techno-literacy practices of emergent readers. The study found that young children experienced a multi-literate practices in their homes that comprised not only print and paper-based literacies but also techno-literacies. That television, games on tablets and phones are the sources of textual pleasure of young children.Families reported that children watched television and play games on tablets/phones regularly. This is due to the limited options of leisure activities available to younger children. Emergent readers are highly focused to televisual text as they demonstrate meaningmaking practices when they constantly ask questions and talk about what they are watching,hence they are active meaning-makers. The learning opportunities which include hand eye coordination, parallel processing, and problem solving skills young children acquired through playing computer games and games on tablet/iPad . Aside from these, they also developed a number of literacy skills as well as how to behave as players.It can be concluded thatexposure to imagery in electronic technologies contributed to the children’s literacy development. The literate identities of emergent readers can be further enhanced as they begin formal schooling. Data indicated that young children are developing techno-literacy practices and this concurs to the findings of Marsh (2010. Therefore, technology serves as a tool for the literacy development of young children. That techno-literacy practices of young children should be valued in school. Future research should also consider attitude, behavior and practices of parents towards the use of technology by children.

  10. Poor readers but compelled to read: Stroop effects in developmental dyslexia.

    Science.gov (United States)

    Faccioli, Chiara; Peru, Andrea; Rubini, Elena; Tassinari, Giancarlo

    2008-05-01

    We studied a group of 24 children with dyslexia in second to fifth primary school grades by using a discrete-trial computerized version of the Stroop Color-Word Test. Since the classic Stroop effect depends on the interference of reading with color naming, one would expect these children to show no interference or, at least, less interference than normal readers. Children with dyslexia showed, however, a Stroop effect larger than normal readers of the same age. This suggests that reading, although difficult and slow, is an inescapable step that precedes naming both in poor and in normal readers.

  11. Novel versatile smart phone based Microplate readers for on-site diagnoses.

    Science.gov (United States)

    Fu, Qiangqiang; Wu, Ze; Li, Xiuqing; Yao, Cuize; Yu, Shiting; Xiao, Wei; Tang, Yong

    2016-07-15

    Microplate readers are important diagnostic instruments, used intensively for various readout test kits (biochemical analysis kits and ELISA kits). However, due to their expensive and non-portability, commercial microplate readers are unavailable for home testing, community and rural hospitals, especially in developing countries. In this study, to provide a field-portable, cost-effective and versatile diagnostic tool, we reported a novel smart phone based microplate reader. The basic principle of this devise relies on a smart phone's optical sensor that measures transmitted light intensities of liquid samples. To prove the validity of these devises, developed smart phone based microplate readers were applied to readout results of various analytical targets. These targets included analanine aminotransferase (ALT; limit of detection (LOD) was 17.54 U/L), alkaline phosphatase (AKP; LOD was 15.56 U/L), creatinine (LOD was 1.35μM), bovine serum albumin (BSA; LOD was 0.0041mg/mL), prostate specific antigen (PSA; LOD was 0.76pg/mL), and ractopamine (Rac; LOD was 0.31ng/mL). The developed smart phone based microplate readers are versatile, portable, and inexpensive; they are unique because of their ability to perform under circumstances where resources and expertize are limited. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. 3D-modeling of the spine using EOS imaging system: Inter-reader reproducibility and reliability.

    Directory of Open Access Journals (Sweden)

    Johannes Rehm

    Full Text Available To retrospectively assess the interreader reproducibility and reliability of EOS 3D full spine reconstructions in patients with adolescent idiopathic scoliosis (AIS.73 patients with mean age of 17 years and a moderate AIS (median Cobb Angle 18.2° obtained low-dose standing biplanar radiographs with EOS. Two independent readers performed "full spine" 3D reconstructions of the spine with the "full-spine" method adjusting the bone contour of every thoracic and lumbar vertebra (Th1-L5. Interreader reproducibility was assessed regarding rotation of every single vertebra in the coronal (i.e. frontal, sagittal (i.e. lateral, and axial plane, T1/T12 kyphosis, T4/T12 kyphosis, L1/L5 lordosis, L1/S1 lordosis and pelvic parameters. Radiation exposure, scan-time and 3D reconstruction time were recorded.Interclass correlation (ICC ranged between 0.83 and 0.98 for frontal vertebral rotation, between 0.94 and 0.99 for lateral vertebral rotation and between 0.51 and 0.88 for axial vertebral rotation. ICC was 0.92 for T1/T12 kyphosis, 0.95 for T4/T12 kyphosis, 0.90 for L1/L5 lordosis, 0.85 for L1/S1 lordosis, 0.97 for pelvic incidence, 0.96 for sacral slope, 0.98 for sagittal pelvic tilt and 0.94 for lateral pelvic tilt. The mean time for reconstruction was 14.9 minutes (reader 1: 14.6 minutes, reader 2: 15.2 minutes, p<0.0001. The mean total absorbed dose was 593.4μGy ±212.3 per patient.EOS "full spine" 3D angle measurement of vertebral rotation proved to be reliable and was performed in an acceptable reconstruction time. Interreader reproducibility of axial rotation was limited to some degree in the upper and middle thoracic spine due the obtuse angulation of the pedicles and the processi spinosi in the frontal view somewhat complicating their delineation.

  13. Diagnostic accuracy of mammography readers and their memory performance have no correlation with each other

    International Nuclear Information System (INIS)

    Kok, P.; Cawson, J.N.; Mercuri, V.; Pitman, A.G.; Gledhill, S.; Shnier, D.; Taft, R.; Zentner, L.

    2010-01-01

    Full text: The study aims to determine if any association exists between visual memory performance and diagnostic accuracy performance in a group of radiologist mammogram readers. Materials and Methods: One hundred proven mammograms (23 with cancers) were grouped into 5 sets of 20 cases, with sets being of equal difficulty. Pairs of sets were presented in 5 reads (40 cases per read, order random) to a panel of 8 radiologist readers (either present or past screening readers, with experience range from 20 years). The readers were asked to either 'clear' or 'call back' cases depending on need for further workup, and at post-baseline reads to indicate whether each case was 'new' or 'old' (i .e. remembered from prior read). Two sets were presented only at baseline (40 cases per reader), and were used to calculate the reader's false recollection rate. Three sets were repeated post-baseline once or twice (100 cases per reader). Reading conditions were standardised. Results: Memory performance differed markedly between readers. The number of correctly remembered cases (of 100 'old' cases) had a median of 10.5 and range of 0-58. The observed number of false recollections (of 40 'totally new' cases) had a median of 2 and range of 0-17. Diagnostic performance measures were mean (range): sensitivity 0.68 (0.54-0.81); specificity 0.82 (0.74-0.91); positive predictive value (PPV) 0.55 (0.500.65); negative predictive value (NPV) 0.89 (0.86-0.93) and accuracy 0.78 (0.76-0.83). Confidence intervals (CIs; 95%) for each reader overlapped for all the diagnostic parameters, indicating a lack of statistically significant difference between the readers at the 5% level. The most sensitive and the most specific reader showed a trend away from each other on sensitivity, specificity, NPV and PPV; their accuracies were 0.76 and 0.82, respectively, and their accuracy 95% CIs overlapped considerably. Correlation analysis by reader showed no association between observed memory performance and

  14. Serving Boys through Readers' Advisory

    Science.gov (United States)

    Sullivan, Michael

    2010-01-01

    Based on more than twenty years' experience working to get boys interested in reading, the author now offers his first readers' advisory volume. With an emphasis on nonfiction and the boy-friendly categories of genre fiction, the work offers a wealth of material including: (1) Suggestions for how to booktalk one-on-one as well as in large groups;…

  15. Chaos control for the plates subjected to subsonic flow

    Science.gov (United States)

    Norouzi, Hamed; Younesian, Davood

    2016-07-01

    The suppression of chaotic motion in viscoelastic plates driven by external subsonic air flow is studied. Nonlinear oscillation of the plate is modeled by the von-Kármán plate theory. The fluid-solid interaction is taken into account. Galerkin's approach is employed to transform the partial differential equations of the system into the time domain. The corresponding homoclinic orbits of the unperturbed Hamiltonian system are obtained. In order to study the chaotic behavior of the plate, Melnikov's integral is analytically applied and the threshold of the excitation amplitude and frequency for the occurrence of chaos is presented. It is found that adding a parametric perturbation to the system in terms of an excitation with the same frequency of the external force can lead to eliminate chaos. Variations of the Lyapunov exponent and bifurcation diagrams are provided to analyze the chaotic and periodic responses. Two perturbation-based control strategies are proposed. In the first scenario, the amplitude of control forces reads a constant value that should be precisely determined. In the second strategy, this amplitude can be proportional to the deflection of the plate. The performance of each controller is investigated and it is found that the second scenario would be more efficient.

  16. The printerless office. A study on the use of e-readers to replace printed paper; Het printerloos kantoor. Een studie naar het gebruik van e-readers ter vervanging van geprint papier

    Energy Technology Data Exchange (ETDEWEB)

    Bijleveld, M.M.; Sevenster, M.N.

    2011-03-15

    A life-cycle analysis was conducted to compare the environmental burden of e-readers with printed paper. The turning point when the e-reader starts to offer environmental benefits over printed paper, at an operational life of two years, lies between 3,000 and 13,000 prints per year. [Dutch] Door middel van levenscyclusanalyse is de milieubelasting van e-readers en geprint papier bepaald en met elkaar vergeleken. Het kantelpunt waarop een e-reader, bij gebruiksduur van 2 jaar, milieuvoordeel gaat bieden boven papieren prints, ligt tussen de 3.000 en 13.000 printjes per jaar.

  17. Development of time-of-flight RBS system using multi microchannel plates

    International Nuclear Information System (INIS)

    Nguyen, N.V.; Abo, S.; Lohner, T.; Sawaragi, H.; Wakaya, F.; Takai, M.

    2007-01-01

    A new time-of-flight Rutherford backscattering spectroscopy (TOF-RBS) system with two circular microchannel plates (MCPs) installed at a distance of 140 mm from a sample holder and a scattering angle of 125 o and a 100 kV focused ion beam column having a liquid metal ion source (LMIS) of AuSiBe alloy has been assembled to obtain high counting rate and enhanced mass resolution. The possible influence of the two MCPs by logical summation of the output signals on the time resolution was investigated by measuring dedicated thin deposited metallic samples. And, the time resolution was found in the range of 1.5-2 ns

  18. Professional writers and empathy: Exploring the barriers to anticipating reader problems

    NARCIS (Netherlands)

    de Jong, Menno D.T.; Lentz, Leo

    2007-01-01

    Research has shown that professional writers cannot accurately predict the problems readers will experience when using functional documents. In this paper, we give an overview of reasons why it can be so hardfor writers to anticipate reader problems. We elaborate on the concept of empathy, and

  19. Eye movement analysis of reading from computer displays, eReaders and printed books.

    Science.gov (United States)

    Zambarbieri, Daniela; Carniglia, Elena

    2012-09-01

    To compare eye movements during silent reading of three eBooks and a printed book. The three different eReading tools were a desktop PC, iPad tablet and Kindle eReader. Video-oculographic technology was used for recording eye movements. In the case of reading from the computer display the recordings were made by a video camera placed below the computer screen, whereas for reading from the iPad tablet, eReader and printed book the recording system was worn by the subject and had two cameras: one for recording the movement of the eyes and the other for recording the scene in front of the subject. Data analysis provided quantitative information in terms of number of fixations, their duration, and the direction of the movement, the latter to distinguish between fixations and regressions. Mean fixation duration was different only in reading from the computer display, and was similar for the Tablet, eReader and printed book. The percentage of regressions with respect to the total amount of fixations was comparable for eReading tools and the printed book. The analysis of eye movements during reading an eBook from different eReading tools suggests that subjects' reading behaviour is similar to reading from a printed book. © 2012 The College of Optometrists.

  20. Fixation of zygomatic and mandibular fractures with biodegradable plates

    OpenAIRE

    Degala, Saikrishna; Shetty, Sujeeth; Ramya, S

    2013-01-01

    Context: In this prospective study, 13 randomly selected patients underwent treatment for zygomatic?complex fractures (2 site fractures) and mandibular fractures using 1.5 / 2 / 2.5-mm INION CPS biodegradable plates and screws. Aims: To assess the fixation of zygomatic-complex and mandibular fractures with biodegradable copolymer osteosynthesis system. Materials and Methods: In randomly selected 13 patients, zygomatic-complex and mandibular fractures were plated using resorbable plates and sc...

  1. Flat plate collector. Solarflachkollektor

    Energy Technology Data Exchange (ETDEWEB)

    Raab, N

    1979-03-29

    The invention refers to a flat solar collector with an absorber plate, which is arranged on a support and is covered by a transparent window, between which and the plate there is an air space. The previously known structures of this type had the disadvantage that the thermal expansion of the enclosed air caused considerable difficulties. The purpose of the invention is therefore to create a collector, which can be used on the modular system, retains its properties and is safe in spite of the great temperature variations. According to the invention this problem is solved by providing a compensating space in the collector, which is separated by a diaphragm from the airspace between the plate and the covering window. The airspace therefore remains sealed against the atmosphere, so that no dirt, corrosion of the inside and no condensation can reduce the efficiency of the collector. A rise in pressure due to an increase in temperature is immediately reduced by expansion of the diaphragm, which enters the compensation space. In order to increase the pressure in the airspace above the plate for increases in temperature, the compensation space is connected to the atmosphere. The diaphragm can be mirrored on the side towards the absorber, which makes the diaphragm into an insulating element, as it reflects radiated heat from the absorber.

  2. Fixation of zygomatic and mandibular fractures with biodegradable plates.

    Science.gov (United States)

    Degala, Saikrishna; Shetty, Sujeeth; Ramya, S

    2013-01-01

    In this prospective study, 13 randomly selected patients underwent treatment for zygomatic-complex fractures (2 site fractures) and mandibular fractures using 1.5 / 2 / 2.5-mm INION CPS biodegradable plates and screws. To assess the fixation of zygomatic-complex and mandibular fractures with biodegradable copolymer osteosynthesis system. In randomly selected 13 patients, zygomatic-complex and mandibular fractures were plated using resorbable plates and screws using Champy's principle. All the cases were evaluated clinically and radiologically for the type of fracture, need for the intermaxillary fixation (IMF) and its duration, duration of surgery, fixation at operation, state of reduction at operation, state of bone union after operation, anatomic reduction, paresthesia, occlusal discrepancies, soft tissue infection, immediate and late inflammatory reactions related to biodegradation process, and any need for the removal of the plates. Descriptives, Frequencies, and Chi-square test were used. In our study, the age group range was 5 to 55 years. Road traffic accidents accounted for the majority of patients six, (46.2%). Postoperative occlusal discrepancies were found in seven patients as mild to moderate, which resolved with IMF for 1-8 weeks. There were minimal complications seen and only as soft tissue infection. Use of biodegradable osteosynthesis system is a reliable alternative method for the fixation of zygomatic-complex and mandibular fractures. The biodegradable system still needs to be refined in material quality and handling to match the stability achieved with metal system. Biodegradable plates and screws is an ideal system for pediatric fractures with favorable outcome.

  3. Systematical and statistical errors in using reference light sources to calibrate TLD readers

    International Nuclear Information System (INIS)

    Burgkhardt, B.; Piesch, E.

    1981-01-01

    Three light sources, namely an NaI(Tl) scintillator + Ra, an NaI(Tl) scintillator + 14 C and a plastic scintillator + 14 C, were used during a period of 24 months for a daily check of two TLD readers: the Harshaw 2000 A + B and the Toledo 651. On the basis of light source measurements long-term changes and day-to-day fluctuations of the reader response were investigated. Systematical changes of the Toledo reader response of up to 6% during a working week are explained by nitrogen effects in the plastic scintillator light source. It was found that the temperature coefficient of the light source intensity was -0.05%/ 0 C for the plastic scintillator and -0.3%/ 0 C for the NaI(Tl) scintillator. The 210 Pb content in the Ra activated NaI(Tl) scintillator caused a time-dependent decrease in light source intensity of 3%/yr for the light source in the Harshaw reader. The internal light sources revealed a relative standard deviation of 0.5% for the Toledo reader and the Harshaw reader after respective reading times of 0.45 and 100 sec. (author)

  4. Training readers at school: the educational project, the school library and the mediation

    Directory of Open Access Journals (Sweden)

    Rovilson José da Silva

    2015-09-01

    Full Text Available Introduction: Discusses the formation of readers in the first years of elementary school and proposes the integration between the school pedagogical project, teachers, reading practices and the school library. Objective: To analyze the basic assumptions to train readers in school. Methods: Bibliographic research based on a literature review on the subject. Results: Initial elements that may be used to structure readers-training projects at any schools are presented. Conclusion: Training readers at school consists in having procedures and pedagogical actions performed in combination with guided and free usage of the library, borrowing books and time to hear stories and talk about them.

  5. Differences in learning volitional (manual and non-volitional (posture aspects of a complex motor skill in young adult dyslexic and skilled readers.

    Directory of Open Access Journals (Sweden)

    Itamar Sela

    Full Text Available The 'Cerebellar Deficit Theory' of developmental dyslexia proposes that a subtle developmental cerebellar dysfunction leads to deficits in attaining 'automatic' procedures and therefore manifests as subtle motor impairments (e.g., balance control, motor skill learning in addition to the reading and phonological difficulties. A more recent version of the theory suggests a core deficit in motor skill acquisition. This study was undertaken to compare the time-course and the nature of practice-related changes in volitional (manual and non-volitional (posture motor performance in dyslexic and typical readers while learning a new movement sequence. Seventeen dyslexic and 26 skilled young adult readers underwent a three-session training program in which they practiced a novel sequence of manual movements while standing in a quiet stance position. Both groups exhibited robust and well-retained gains in speed, with no loss of accuracy, on the volitional, manual, aspects of the task, with a time-course characteristic of procedural learning. However, the dyslexic readers exhibited a pervasive slowness in the initiation of volitional performance. In addition, while typical readers showed clear and well-retained task-related adaptation of the balance and posture control system, the dyslexic readers had significantly larger sway and variance of sway throughout the three sessions and were less efficient in adapting the posture control system to support the acquisition of the novel movement sequence. These results support the notion of a non-language-related deficit in developmental dyslexia, one related to the recruitment of motor systems for effective task performance rather than to a general motor learning disability.

  6. Base-plate effects on pipe-support stiffness

    International Nuclear Information System (INIS)

    Winkel, B.V.; LaSalle, F.R.

    1981-01-01

    Present nuclear power plant design methods require that pipe support spring rates be considered in the seismic design of piping systems. Base plate flexibility can have a significant effect on the spring rates of these support structures. This paper describes the field inspection, test, and analytical techniques used to identify and correct excessively flexible base plates on the Fast Flux Test Facility pipe support structures

  7. Evaluation of edge enhancement effect of phase contrast imaging using newly-developed photostimulable phosphor plate

    International Nuclear Information System (INIS)

    Matsuo, Satoru; Morishita, Junji; Katafuchi, Tetsuro; Fujita, Hiroshi

    2012-01-01

    We investigated whether the use of a newly developed columnar-crystal-type photostimulable-phosphor plate (CP1M200, referred to as system C) helps to provide improved edge-enhanced effect in phase contrast imaging. Physical characteristics of 2 conventional particulate-crystal-type photostimulable-phosphor plates (RP-5PM, referred to as system A and RP-6M, referred to as system B) and system C were measured. Then, an acrylic plate phantom and RMI152 phantom were imaged using 3 types of plates, and the edge-enhancement effects were evaluated based on the profile curve of the acrylic plate phantom. Visual evaluation of the RMI152 phantom images was conducted. The results showed that the modulation transfer function (MTF) of system C was superior to those of the other systems. The WS of system C was superior to those of the other systems in the low frequency band region, and inferior to those of the other systems in the high frequency band region. The presence of an edge-enhanced image was not detectable in the profile curve of the acrylic plate in system A, although that was shown in systems B and C due to their excellent sharpness. In the visual image evaluation of the RMI152 phantom, image quality of system C was superior to those of the other systems. Phase contrast imaging with a digital detector of a columnar-crystal-type photostimulable-phosphor plate is considered to provide improved edge-enhancement over that of conventional plates. (author)

  8. Energy response of imaging plates to radiation beams from standard beta sources, ortho-voltage and cobalt-60 units and linear accelerators

    Science.gov (United States)

    Gonzalez, Albin Leonel

    The response to different types of radiation beams of commercial imaging plates used for diagnostic computed radiography has been investigated in this work. Imaging plates are designed with a phosphor layer which after been irradiated; information is stored in the form of photostimulable luminescence (PSL) centers. Initial measurements of the dose distribution of a radioactive stent with the imaging plates showed similar results to those with radiochromic films, but with much shorter exposure time due to their higher sensitivity. In order to investigate further their response, the imaging plates were irradiated with calibrated beams from: standard beta sources, orthovoltage and Co-60 units and therapy linear accelerator. Initially it was found that the energy to create the storage centers (generation efficiency) when irradiated with the three standard beta sources (225 keV to 2.28 MeV) was the same. For the rest of the calibrated beams an in house reader system was built in order to perform the bleaching of the plates with a He-Ne laser (632.8 nm) and to measure the absolute number of the emitted PSL photons (storage centers produced). Bleaching curves were then obtained for different exposure times for each beam. From the graph of the calculated area under the bleaching curves (total number of storage center) versus the absorbed dose to the phosphor layer it was possible to calculate the energy to create the storage centers (generation efficiency) for photon and electron beams. The dose to the phosphor layer was calculated in the case of the electron beams following a scaling procedure, while in the case of the photon beams Monte Carlo simulations were performed. For the photons beams the measurement of the generation efficiency energy of 126 +/- 8% eV per PSL storage center, coincide with measurements using a different approach (˜148 eV) by previous investigators. The generation efficiency for the electron beam was 807 +/- 3% eV, no reference was found in the

  9. Cancer on a mammogram is not memorable: readers remember their recalls and not cancers

    International Nuclear Information System (INIS)

    Pitman, Alexander G.; Kok, Phebe; Zentner, Lucila

    2012-01-01

    To determine if presence of cancer on a mammogram makes that mammogram more memorable. A total of 100 mammograms (25 cancers) were grouped into 5 sets of 20 cases. Set pairs were presented in five reads to eight radiologist readers. Readers were asked to 'clear' or 'call back' cases, and at post-baseline reads to indicate whether each case was 'new' or 'old ' (remembered from prior read). Two sets were presented only at baseline, to calculate each reader's false recollection rate. For cases presented more than once ('old' cases, 100 presentations) readers could have 'correct memory' or 'memory loss'. Memory performance was defined as odds ratio of correct memory to memory loss. Multivariate logistic data regression analysis identified predictors of memory performance from: reader, set, time since last read, presence of cancer, and whether the case was called back at the last read. Memory performance differed markedly between readers and reader identity was a highly significant predictor of memory performance. Presence of cancer was not a significant predictor of memory performance (odds ratio 0.77, 95% CI: 0.49–1.21). Whether the case was called back at the last read was a highly significant predictor (odds ratio 4.22, 95% CI: 2.70–6.61) for the model incorporating reader variability, and also the model without reader variability (odds ratio 2.67, 95% CI: 1.74–4.08). The only statistically significant predictor of radiologist memory for a mammogram was whether the radiologist 'called it back' at a prior reading round. Presence of cancer on a mammogram did not make it memorable.

  10. A locking compression plate versus the gold-standard non-locking plate with lag screw for first metatarsophalangeal fusion: A biomechanical comparison.

    Science.gov (United States)

    Mandell, Daniel; Karbassi, John; Zhou, Hanbing; Burroughs, Brian; Aurigemma, Philip; Patel, Abhay R

    2018-03-01

    The treatment of end-stage first metatarso-phalangeal joint (MTP) arthritis has been arthrodesis. A dorsal non-locking plate with a lag screw has been the standard traditional fixation method. This study compares the biomechanical strength of a locking compression plate (LCP) with and without internal compression versus this known gold standard. In group 1, six matched pairs of cadaver great toes were used to compare the standard non-locking dorsal plate and 3.5mm lag screw to an anatomic locking compression plate in which a lag screw was utilized rather than the internal compression features of the plate. In group 2, another six matched pairs of cadaver great toes were used to compare the gold standard to the locking compression plate, utilizing the plate's internal compression feature instead of a lag screw. A material testing system (MTS) machine applied loads to the MTP joints and measured displacement and stiffness of the constructs. The stiffness of the constructs (Young's modulus) was calculated from the force-displacement curves, and the displacement was measured. The locking compression plate group that used the compression features of the plate, without the lag screw, had less joint displacement and higher stiffness than control (p<0.05). The same plating construct in which a lag screw was used rather than internal compression of the plate was found to be stiffer than the control (p<0.05), but displacement was not statistically significant. The results suggest that a locking compression plate alone provides the stiffest construct for a first MTP joint fusion. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. So Long, Robot Reader! A Superhero Intervention Plan for Improving Fluency

    Science.gov (United States)

    Marcell, Barclay; Ferraro, Christine

    2013-01-01

    This article presents an engaging means for turning disfluent readers into prosody superstars. Each week students align with Poetry Power Man and his superhero friends to battle the evil Robot Reader and his sidekicks. The Fluency Foursome helps students adhere to the multidimensional aspects of fluency where expression and comprehension are…

  12. Buckling Response of Thick Functionally Graded Plates

    Directory of Open Access Journals (Sweden)

    BOUAZZA MOKHTAR

    2014-11-01

    Full Text Available In this paper, the buckling of a functionally graded plate is studied by using first order shear deformation theory (FSDT. The material properties of the plate are assumed to be graded continuously in the direction of thickness. The variation of the material properties follows a simple power-law distribution in terms of the volume fractions of constituents. The von Karman strains are used to construct the equilibrium equations of the plates subjected to two types of thermal loading, linear temperature rise and gradient through the thickness are considered. The governing equations are reduced to linear differential equation with boundary conditions yielding a simple solution procedure. In addition, the effects of temperature field, volume fraction distributions, and system geometric parameters are investigated. The results are compared with the results of the no shear deformation theory (classic plate theory, CPT.

  13. A Possible Differentially Shortened Strike-slip Plate Boundary: the Okhotsk Plate Example.

    Science.gov (United States)

    Hindle, D.; Egorov, V.; Mackey, K. G.; Fujita, K.

    2004-12-01

    The Okhotsk plate has been postulated based on a combination of GPS geodetic inversions (REVEL1), seimsicity, geologic and lineament data. Lying between the North American and Eurasian plates, its northwestern corner would appear to be undergoing compression in a scissors motion between the two bounding plates. Extrusion tectonics along multiple, large strike-slip faults within the Okhotsk plate itself have been suggested to allow the escape of material away from the apex of Eurasia-North America. The plate boundary between Okhotsk and North America has been suggested to be diffuse, based on widely scattered minor seismicity. However, the large, left lateral, Ulakhan fault has also been suggested as a candidate plate boundary. We present field geological and geomorphological evidence of the partitioning of deformation between the Ulakhan fault, and several parallel and oblique, linked faults. The Ulakhan fault strand appears to have a maximum displacement of 24 km based on river valley offsets and closing large pull apart basins. Some of the displacement from the Ulakhan fault appears relayed into the plate margin along oblique trending, thrust/oblique slip faults. Estimated shortening over these faults is equivalent to the amount of shortening relayed into the plate margin from the plate boundary. There may be several thrust/oblique slip faults along the Ulakhan fault, which leads to the interesting situation of a segmented, strike-slip plate boundary being actively shortened in a margin parallel direction. This may be the result of postulated extrusion of the Okhotsk plate due to North America/Eurasia convergence. Such a situation would have important consequences for the interpretation of GPS data in a plate tectonic context.

  14. Does Feeling Come First? How Poetry Can Help Readers Broaden Their Understanding of Metacognition

    Science.gov (United States)

    Eva-Wood, Amy L.

    2008-01-01

    Assuming that readers' emotional responses can enhance readers' metacognitive experiences and inform literary analysis, this study of 11th-grade poetry readers features instruction that models both cognitive and affective reading processes. The author: (1) Presents a case for more explicit attention to emotion in language arts classrooms; (2)…

  15. Mind the Gap: Bridging the Divide between Non-Readers and Lifelong Readers with Hi-Lo Books

    Science.gov (United States)

    Gleason, Carrie

    2011-01-01

    In the past few years, there has been increasing demand from school librarians for books for "reluctant readers"--despite the impressive offering of children's literature published each year and the success of blockbuster series like "Harry Potter, Diary of a Wimpy Kid, Twilight," and "Hunger Games," among others. This is also in addition to all…

  16. Every reader his book – every book its reader?

    DEFF Research Database (Denmark)

    Kann-Christensen, Nanna; Balling, Gitte

    2014-01-01

    ’ advisory and audience development. This is achieved through an analysis of opinions and reflections expressed by 13 managers and librarians in all six county libraries in Denmark. The interviews are analysed through the model which merges three concepts: cultural policy, new public management......Collections are no longer the main attraction in libraries, and libraries are working to find new paths to tread. One strategy is to focus on reading and literature in new and surprising ways. The aim of this article is to enrich an understanding of activities situated in the span between readers...... and professional logics. Our findings show that Danish librarians’ views on readers’ advisory and audience development strike a balance between the experience and empowerment rationales with a prevailing focus on users. A user orientation and focus on user experiences have created a situation wherein the notions...

  17. High-Throughput Lipolysis in 96-Well Plates for Rapid Screening of Lipid-Based Drug Delivery Systems

    DEFF Research Database (Denmark)

    Mosgaard, Mette D; Sassene, Philip J; Mu, Huiling

    2017-01-01

    The high-throughput in vitro intestinal lipolysis model (HTP) applicable for rapid and low-scale screening of lipid-based drug delivery systems (LbDDSs) was optimized and adjusted as to be conducted in 96-well plates (HTP-96). Three different LbDDSs (I-III) loaded with danazol or cinnarizine were...

  18. Numerical modeling of intraplate seismicity with a deformable loading plate

    Science.gov (United States)

    So, B. D.; Capitanio, F. A.

    2017-12-01

    We use finite element modeling to investigate on the stress loading-unloading cycles and earthquakes occurrence in the plate interiors, resulting from the interactions of tectonic plates along their boundary. We model a visco-elasto-plastic plate embedding a single or multiple faults, while the tectonic stress is applied along the plate boundary by an external loading visco-elastic plate, reproducing the tectonic setting of two interacting lithospheres. Because the two plates deform viscously, the timescale of stress accumulation and release on the faults is self-consistently determined, from the boundary to the interiors, and seismic recurrence is an emerging feature. This approach overcomes the constraints on recurrence period imposed by stress (stress-drop) and velocity boundary conditions, while here it is unconstrained. We illustrate emerging macroscopic characteristics of this system, showing that the seismic recurrence period τ becomes shorter as Γ and Θ decreases, where Γ = ηI/ηL the viscosity ratio of the viscosities of the internal fault-embedded to external loading plates, respectively, and Θ = σY/σL the stress ratio of the elastic limit of the fault to far-field loading stress. When the system embeds multiple, randomly distributed faults, stress transfer results in recurrence period deviations, however the time-averaged recurrence period of each fault show the same dependence on Γ and Θ, illustrating a characteristic collective behavior. The control of these parameters prevails even when initial pre-stress was randomly assigned in terms of the spatial arrangement and orientation on the internal plate, mimicking local fluctuations. Our study shows the relevance of macroscopic rheological properties of tectonic plates on the earthquake occurrence in plate interiors, as opposed to local factors, proposing a viable model for the seismic behavior of continent interiors in the context of large-scale, long-term deformation of interacting tectonic

  19. The Use of the String of Pearls Locking Plate System in the Stabilisation of a Comminuted Calcaneal Fracture in a Giant Breed Dog

    Directory of Open Access Journals (Sweden)

    A. B. Scrimgeour

    2011-01-01

    Full Text Available An eight-year-old male Pyrenean mountain dog was presented with a comminuted fracture of the right calcaneus following motor vehicle trauma. The fracture was stabilised with a plate-rod construct, using the String of Pearls locking plate system and an intramedullary pin. Healing was uncomplicated.

  20. Parietotemporal Stimulation Affects Acquisition of Novel Grapheme-Phoneme Mappings in Adult Readers

    Directory of Open Access Journals (Sweden)

    Jessica W. Younger

    2018-03-01

    Full Text Available Neuroimaging work from developmental and reading intervention research has suggested a cause of reading failure may be lack of engagement of parietotemporal cortex during initial acquisition of grapheme-phoneme (letter-sound mappings. Parietotemporal activation increases following grapheme-phoneme learning and successful reading intervention. Further, stimulation of parietotemporal cortex improves reading skill in lower ability adults. However, it is unclear whether these improvements following stimulation are due to enhanced grapheme-phoneme mapping abilities. To test this hypothesis, we used transcranial direct current stimulation (tDCS to manipulate parietotemporal function in adult readers as they learned a novel artificial orthography with new grapheme-phoneme mappings. Participants received real or sham stimulation to the left inferior parietal lobe (L IPL for 20 min before training. They received explicit training over the course of 3 days on 10 novel words each day. Learning of the artificial orthography was assessed at a pre-training baseline session, the end of each of the three training sessions, an immediate post-training session and a delayed post-training session about 4 weeks after training. Stimulation interacted with baseline reading skill to affect learning of trained words and transfer to untrained words. Lower skill readers showed better acquisition, whereas higher skill readers showed worse acquisition, when training was paired with real stimulation, as compared to readers who received sham stimulation. However, readers of all skill levels showed better maintenance of trained material following parietotemporal stimulation, indicating a differential effect of stimulation on initial learning and consolidation. Overall, these results indicate that parietotemporal stimulation can enhance learning of new grapheme-phoneme relationships in readers with lower reading skill. Yet, while parietotemporal function is critical to new

  1. Parietotemporal Stimulation Affects Acquisition of Novel Grapheme-Phoneme Mappings in Adult Readers

    Science.gov (United States)

    Younger, Jessica W.; Booth, James R.

    2018-01-01

    Neuroimaging work from developmental and reading intervention research has suggested a cause of reading failure may be lack of engagement of parietotemporal cortex during initial acquisition of grapheme-phoneme (letter-sound) mappings. Parietotemporal activation increases following grapheme-phoneme learning and successful reading intervention. Further, stimulation of parietotemporal cortex improves reading skill in lower ability adults. However, it is unclear whether these improvements following stimulation are due to enhanced grapheme-phoneme mapping abilities. To test this hypothesis, we used transcranial direct current stimulation (tDCS) to manipulate parietotemporal function in adult readers as they learned a novel artificial orthography with new grapheme-phoneme mappings. Participants received real or sham stimulation to the left inferior parietal lobe (L IPL) for 20 min before training. They received explicit training over the course of 3 days on 10 novel words each day. Learning of the artificial orthography was assessed at a pre-training baseline session, the end of each of the three training sessions, an immediate post-training session and a delayed post-training session about 4 weeks after training. Stimulation interacted with baseline reading skill to affect learning of trained words and transfer to untrained words. Lower skill readers showed better acquisition, whereas higher skill readers showed worse acquisition, when training was paired with real stimulation, as compared to readers who received sham stimulation. However, readers of all skill levels showed better maintenance of trained material following parietotemporal stimulation, indicating a differential effect of stimulation on initial learning and consolidation. Overall, these results indicate that parietotemporal stimulation can enhance learning of new grapheme-phoneme relationships in readers with lower reading skill. Yet, while parietotemporal function is critical to new learning, its role in

  2. Struggling Readers: Assessment and Instruction in Grades K-6. Solving Problems in the Teaching of Literacy.

    Science.gov (United States)

    Balajthy, Ernest; Lipa-Wade, Sally

    This book focuses on three distinct types of struggling readers that teachers will instantly recognize from their own classrooms--the "Catch-On Reader," the "Catch-Up Reader," and the "Stalled Reader." The book provides detailed case studies which bring to life the specific problems these students are likely to face…

  3. Reverse Less Invasive Stabilization System (LISS) Plating for Proximal Femur Fractures in Poliomyelitis Survivors: A Report of Two Cases.

    Science.gov (United States)

    Yao, Chen; Jin, Dongxu; Zhang, Changqing

    2017-11-15

    BACKGROUND Poliomyelitis is a neuromuscular disease which causes muscle atrophy, skeletal deformities, and disabilities. Treatment of hip fractures on polio-affect limbs is unique and difficult, since routine fixation methods like nailing may not be suitable due to abnormal skeletal structures. CASE REPORT We report one femoral neck fracture and one subtrochanteric fracture in polio survivors successfully treated with reverse less invasive stabilization system (LISS) plating technique. Both fractures were on polio-affected limbs with significant skeletal deformities and low bone density. A contralateral femoral LISS plate was applied upside down to the proximal femur as an internal fixator after indirect or direct reduction. Both patients had uneventful bone union and good functional recovery. CONCLUSIONS Reverse LISS plating is a safe and effective technique to treat hip fractures with skeletal deformities caused by poliomyelitis.

  4. Two ways of constructing the reader`s subject position: a discursive analysis of the newspaper language of the newspapers Diário Catarinense and Hora de Santa Catarina

    Directory of Open Access Journals (Sweden)

    Sandro Braga

    2012-12-01

    Full Text Available We analyze, based on French Discourse Analysis, how the newspapers Diário Catarinense and Hora de Santa Catarina produce different reader`s subject positions. This research is justified by the fact that both newspapers are products of the same media company. The starting point was the hypothesis that there would be in the market two types of readers, thus the two products do not compete with each other, but they would complement each other in the coverage of a reading area. Reading here is treated as a process of production of sense effects. The work is based on Orlandi`s thinking about the conception of reading, as well as in the distinction between real and virtual reader. We do also present the clues included in the statements which inferences are essential to apprehend the said and the unsaid which, by means of a comparative analysis, was used to understand the production of different reader’s subject position. The analysis points out that the newspapers DC and Hora present similar characteristics in regard to the process of transmitting information, howevereach newspaper interrelates with its target public in a different way through the use of language and in the manner of production of news. It leads to the construction of different positions of these readers in relation to the information which is transmitted, because, making use of uttering strategies, these newspapers ideologically mark the readers of DC as being more lettered than the ones of Hora.

  5. Predicting Text Comprehension, Processing, and Familiarity in Adult Readers: New Approaches to Readability Formulas

    Science.gov (United States)

    Crossley, Scott A.; Skalicky, Stephen; Dascalu, Mihai; McNamara, Danielle S.; Kyle, Kristopher

    2017-01-01

    Research has identified a number of linguistic features that influence the reading comprehension of young readers; yet, less is known about whether and how these findings extend to adult readers. This study examines text comprehension, processing, and familiarity judgment provided by adult readers using a number of different approaches (i.e.,…

  6. Networks of reader and country status: an analysis of Mendeley reader statistics

    Directory of Open Access Journals (Sweden)

    Robin Haunschild

    2015-11-01

    Full Text Available The number of papers published in journals indexed by the Web of Science core collection is steadily increasing. In recent years, nearly two million new papers were published each year; somewhat more than one million papers when primary research papers are considered only (articles and reviews are the document types where primary research is usually reported or reviewed. However, who reads these papers? More precisely, which groups of researchers from which (self-assigned scientific disciplines and countries are reading these papers? Is it possible to visualize readership patterns for certain countries, scientific disciplines, or academic status groups? One popular method to answer these questions is a network analysis. In this study, we analyze Mendeley readership data of a set of 1,133,224 articles and 64,960 reviews with publication year 2012 to generate three different networks: (1 The network based on disciplinary affiliations of Mendeley readers contains four groups: (i biology, (ii social sciences and humanities (including relevant computer sciences, (iii bio-medical sciences, and (iv natural sciences and engineering. In all four groups, the category with the addition “miscellaneous” prevails. (2 The network of co-readers in terms of professional status shows that a common interest in papers is mainly shared among PhD students, Master’s students, and postdocs. (3 The country network focusses on global readership patterns: a group of 53 nations is identified as core to the scientific enterprise, including Russia and China as well as two thirds of the OECD (Organisation for Economic Co-operation and Development countries.

  7. A counterexample of the Euler condition: the Appell–Hamel dynamical system on a horizontally moving plate

    International Nuclear Information System (INIS)

    Shan-Shan, Xu; Shu-Min, Li; Jamal, Berakdar

    2009-01-01

    As a counterexample of the Euler condition for nonholonomic constraint problems [H. C. Shen, Acta Phys. Sin. 54, 2468 (2005)], we investigate the Apell–Hamel dynamical system on a horizontally moving plate. The inconsistency of the results with Newton mechanics suggests that the Euler condition is not a universal model for nonlinear nonholonomic systems. This is attributed to the fact that the virtual displacements so obtained are not normal to the constraint forces. (general)

  8. Numerical Study on the Effect of Distribution Plates in the Manifolds on the Flow Distribution and Thermal Performance of a Flat Plate Solar Collector

    Directory of Open Access Journals (Sweden)

    Juan Manuel García-Guendulain

    2018-04-01

    Full Text Available Flow maldistribution represents a problem of particular interest in the engineering field for several thermal systems. In flat plate solar collectors, the thermal efficiency strongly depends on the flow distribution through the riser tubes, where a uniform distribution causes a uniform temperature distribution and therefore a higher efficiency. In this work, a Computational Fluid Dynamics (CFD numerical analysis has been carried out using the commercial software FLUENT®, in order to determine the flow distribution, pressure drop and hence the thermal efficiency of a solar collector with distribution flow plates inside the manifolds. The obtained numerical solution for this type of thermal systems has been validated with experimental results available in literature for laminar and turbulent flow. Four distribution plate configurations were analyzed. Results show that using two distribution plates in each of both manifolds improves the flow uniformity up to 40% under the same operating conditions when distribution plates are not used. Besides, it is shown that there exists an increase in the overall pressure drop which is practically negligible for the tilt angles commonly employed in the installation of flat plate solar collectors in Mexico. The use of closed end distribution plates on the dividing and combining manifolds allows the thermal efficiency to become close to the ideal thermal efficiency which is obtained with a uniform flow distribution.

  9. Sound insulation performance of plates with interconnected distributed piezoelectric patches

    Directory of Open Access Journals (Sweden)

    Yi Kaijun

    2017-02-01

    Full Text Available This paper deals with the sound insulation performance of a thin plate with interconnected distributed piezoelectric patches. Piezoelectric patches are periodically bonded on the surfaces of the plate in a collocated fashion, and are interconnected via an inductive circuit network. This piezoelectric system is termed as piezo-electromechanical (PEM plate in the paper. Homogenization methods are involved under a sub-wavelength assumption to analytically develop the dynamical equations for the PEM plate. The dispersion relationships and energy densities of the wave modes propagating in the PEM plate are studied; the sub-wavelength assumption is verified for the simulations in this paper. The coincidence frequency of the PEM plate is researched, and results show that the coincidence frequency of the PEM plate will disappear at certain circumstances; mathematical and physical explanations are made for this phenomenon. The disappearance of the coincidence frequency is used to optimize the value of inductance, for the purpose of improving the sound transmission loss of the PEM plate.

  10. Development of Intermediate Cooling Technology and Its Control for Two-Stand Plate Rolling

    Directory of Open Access Journals (Sweden)

    Fei Zhang

    2016-01-01

    Full Text Available In a plate rolling production line, thermomechanically controlled processing is critical for plate quality. In this paper, a set of intermediate cooling equipment of a two-stand plate mill with super density nozzles, medium pressure, and small flow is developed. Based on a simplified dynamic model, a cooling control scheme with combined feedforward, feedback, and adaptive algorithms is put forward. The new controlled rolling process and the highly efficient control system improve the controlled rolling efficiency by an average of 17.66%. The proposed intermediate cooling system can also effectively inhibit the growth of austenite grain, improve the impact toughness and yield strength of Q345B steel plate, reduce the formation of secondary oxide scale on the plate surface and the chromatic aberration of the plate surface, and greatly improve the surface quality of the steel plate.

  11. Processamento cognitivo em crianças com e sem dificuldades de leitura Cognitive skills in children: comparing good readers and poor readers

    Directory of Open Access Journals (Sweden)

    Alessandra Gotuzo Seabra Capovilla

    2004-12-01

    Full Text Available Para buscar identificar habilidades cognitivas mais freqüentemente prejudicadas nas dificuldades de leitura, 90 crianças de pré-escola e 1ª Série foram avaliadas em leitura, escrita, consciência fonológica, memória fonológica, vocabulário, aritmética, processamento visual e seqüenciamento. Comparando as habilidades de bons e maus leitores (acima e abaixo de 1 desvio-padrão em relação à média, respectivamente, observou-se que bons leitores foram significativamente superiores em escrita, consciência fonológica, vocabulário, memória fonológica e memória visual. Resultados sugerem uma relação funcional e forte entre processamento fonológico e leitura; funcional e moderada entre processamento seqüencial, aritmética e leitura; e fraca e correlacional entre processamento visual e leitura.To identify cognitive skills that may be diminished in reading difficulties, 90 preschoolers and first graders were tested in reading, spelling, phonological awareness, phonological memory, vocabulary, arithmetic, visual processing, and sequential processing. Comparison between good readers and poor readers (above and below one standard deviation, respectively, revealed that good readers were significantly superior to poor readers in spelling, phonological awareness, vocabulary, phonological memory and visual memory. Results suggest strong functional relationship between phonological processing and reading, moderate functional relationships between sequential processing and arithmetic on one hand and reading on the other, and weak correlation between visual processing and reading.

  12. Effect of Plate Curvature on Blast Response of Structural Steel Plates

    Science.gov (United States)

    Veeredhi, Lakshmi Shireen Banu; Ramana Rao, N. V.; Veeredhi, Vasudeva Rao

    2018-04-01

    In the present work an attempt is made, through simulation studies, to determine the effect of plate curvature on the blast response of a door structure made of ASTM A515 grade 50 steel plates. A door structure with dimensions of 5.142 m × 2.56 m × 10 mm having six different radii of curvatures is analyzed which is subjected to blast load. The radii of curvature investigated are infinity (flat plate), 16.63, 10.81, 8.26, 6.61 and 5.56 m. In the present study, a stand-off distance of 11 m is considered for all the cases. Results showed that the door structure with smallest radius of curvature experienced least plastic deformation and yielding when compared to a door with larger radius of curvature with same projected area. From the present Investigation, it is observed that, as the radius of curvature of the plate increases, the deformation mode gradually shifts from indentation mode to flexural mode. The plates with infinity and 16.63 m radius of curvature have undergone flexural mode of deformation and plates with 6.61 and 5.56 m radius of curvature undergo indentation mode of deformation. Whereas, mixed mode of deformation that consists of both flexural and indentation mode of deformations are seen in the plates with radius of curvature 10.81 and 8.26 m. As the radius of curvature of the plate decreases the ability of the plate to mitigate the effect the blast loads increased. It is observed that the plate with smaller radius of curvature deflects most of the blast energy and results in least indentation mode of deformation. The most significant observation made in the present investigation is that the strain energy absorbed by the steel plate gets reduced to 1/3 rd when the radius of curvature is approximately equal to the stand-off distance which could be the critical radius of curvature.

  13. Selecting "App"ealing and "App"ropriate Book Apps for Beginning Readers

    Science.gov (United States)

    Cahill, Maria; McGill-Franzen, Anne

    2013-01-01

    Beginning with a brief rationale for selecting quality digital picture book apps for beginning readers, the authors describe the elements of digital picture books and provide a brief review of the instructional benefits of digital picture book use for beginning readers. They then present a detailed taxonomy for selecting quality picture book apps.…

  14. The Experiences in Processing Policies and Contracts by Adult ESL Readers

    Science.gov (United States)

    Abiog, Evalyn B.

    2017-01-01

    The present study describes the experiences of adult English as a Second Language (ESL) readers in processing legal texts prior to entering a financial agreement. A preliminary survey was conducted to determine the commonly read policies and contracts of adult ESL reader-consumers, which revealed those of banks and life-insurance companies; hence,…

  15. The Okhotsk Plate and the Eurasia-North America plate boundary zone.

    Science.gov (United States)

    Hindle, David; Mackey, Kevin

    2014-05-01

    The Eurasia-North America plate boundary zone transitions from spreading at rates of ~ 25mm/yr in the North Atlantic, to compression at rates of ~ 5mm/yr in the region of the Okhotsk plate. Because the pole of rotation between Eurasia and North America lies more or less on their mutual boundary, there is a linear change in rate along the boundary, and regions near the euler pole are subject to extremely low deformation rates. The Okhotsk - Eurasia - North America triple junction lies slightly south of the rotation pole, placing the Okhotsk plate entirely in a weakly contractional setting. Regions near the triple junction absorb 1mm/yr contraction. Further south, towards the shoreline of the Okhotsk sea, up to 5 mm/yr contraction may be absorbed within the plate. How shortening is accommodated across the boundary remains an open question. One possibility is wholesale extrusion of the entire Okhotsk plate (or possibly its northwestern corner) along two plate boundary strike slip faults (Eurasia-Okhostk and North America Okhotsk). The problem with this model is that the seismic record does not presently clearly support it, with the largest events distributed both within the plate interior and on its boundaries. This may suggest that instead, the Okhotsk plate, and particularly its north-western end, consists of a series of smaller blocks which shuffle against each other, partially accommodating extrusion, but also permitting some internal deformation and change of shape of the Okhotsk plate itself. We present analyses of the very sparse seismic record from the region, as well as geometric-kinematic, tectonic models of the possible deformation of northwest Okhotsk to try to better understand the different probabilities of how this slowly deforming plate boundary zone is behaving.

  16. DESI focal plate mechanical integration and cooling

    Science.gov (United States)

    Lambert, A. R.; Besuner, R. W.; Claybaugh, T. M.; Silber, J. H.

    2016-08-01

    The Dark Energy Spectroscopic Instrument (DESI) is under construction to measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique[1]. The spectra of 40 million galaxies over 14000 sq. deg will be measured during the life of the experiment. A new prime focus corrector for the KPNO Mayall telescope will deliver light to 5000 fiber optic positioners. The fibers in turn feed ten broad-band spectrographs. This paper describes the mechanical integration of the DESI focal plate and the thermal system design. The DESI focal plate is comprised of ten identical petal assemblies. Each petal contains 500 robotic fiber positioners. Each petal is a complete, self-contained unit, independent from the others, with integrated power supply, controllers, fiber routing, and cooling services. The major advantages of this scheme are: (1) supports installation and removal of complete petal assemblies in-situ, without disturbing the others, (2) component production, assembly stations, and test procedures are repeated and parallelizable, (3) a complete, full-scale prototype can be built and tested at an early date, (4) each production petal can be surveyed and tested as a complete unit, prior to integration, from the fiber tip at the focal surface to the fiber slit at the spectrograph. The ten petal assemblies will be installed in a single integration ring, which is mounted to the DESI corrector. The aluminum integration ring attaches to the steel corrector barrel via a flexured steel adapter, isolating the focal plate from differential thermal expansions. The plate scale will be kept stable by conductive cooling of the petal assembly. The guider and wavefront sensors (one per petal) will be convectively cooled by forced flow of air. Heat will be removed from the system at ten liquid-cooled cold plates, one per petal, operating at ambient temperature. The entire focal plate structure is enclosed in an insulating shroud, which serves as a thermal barrier

  17. Crane Scheduling for a Plate Storage

    DEFF Research Database (Denmark)

    Hansen, Jesper; Clausen, Jens

    2002-01-01

    Odense Steel Shipyard produces the worlds largest container ships. The first process of producing the steel ships is handling arrival and storage of steel plates until they are needed in production. This paper considers the problem of scheduling two cranes that carry out the movements of plates...... into, around and out of the storage. The system is required to create a daily schedule for the cranes, but also handle possible disruptions during the execution of the plan. The problem is solved with a Simulated Annealing algorithm....

  18. Fabrication procedures for HFIR control plates

    Energy Technology Data Exchange (ETDEWEB)

    Bowden, G.A.; Hicks, G.R.; Knight, R.W.

    1984-10-01

    The HFIR control system uses Alclad cylindrically shaped components, which have regions containing 31 vol % Eu/sub 2/O/sub 3/ and 38 vol % Ta, respectively. Exacting control of the water passage between these components and adjacent reactor parts is mandatory, and precise dimensional control of the finished products is required. This report describes the procedures developed for manufacturing outer control plates and inner control cylinders. Results are cited which demonstrate that circular-shaped outer control plates can be produced with less than 0.025-in. variation from the specified 9.300-in. radius in any region of the plate. Other results show that, by the exercise of careful control, inner control, inner control plates can be welded into cylindrical geometry with diametrical variations held to less than +- 0.010 in. of the intended 17.846-in. average diam. The cylinders can then be explosively sized, while under compression, with diametric variations of less than 0.005 in. while controlling roundness variations to less than 0.030 in. from the specified 17.842-in. finished diam.

  19. Fabrication procedures for HFIR control plates

    International Nuclear Information System (INIS)

    Bowden, G.A.; Hicks, G.R.; Knight, R.W.

    1984-10-01

    The HFIR control system uses Alclad cylindrically shaped components, which have regions containing 31 vol % Eu 2 O 3 and 38 vol % Ta, respectively. Exacting control of the water passage between these components and adjacent reactor parts is mandatory, and precise dimensional control of the finished products is required. This report describes the procedures developed for manufacturing outer control plates and inner control cylinders. Results are cited which demonstrate that circular-shaped outer control plates can be produced with less than 0.025-in. variation from the specified 9.300-in. radius in any region of the plate. Other results show that, by the exercise of careful control, inner control, inner control plates can be welded into cylindrical geometry with diametrical variations held to less than +- 0.010 in. of the intended 17.846-in. average diam. The cylinders can then be explosively sized, while under compression, with diametric variations of less than 0.005 in. while controlling roundness variations to less than 0.030 in. from the specified 17.842-in. finished diam

  20. Research on Positioning Algorithm of Forklift-mounted RFID Reader

    Directory of Open Access Journals (Sweden)

    Hongjin Wang

    2014-07-01

    Full Text Available To conduct real-time and accurate positioning of the forklifts (people and goods in the warehouse is an effective means for improving warehouse management efficiency. To this end, this article puts forward the active positioning system with the forklift installed with RFID reader and the ground passageway embedded with RFID tag. In the running process, the position of forklift can be determined through recognition of the reference tags which are embedded at both sides of the passageway based on the three-side layout at right angle principle and their RSSI value. The positional accuracy can be improved by adjusting the layout distance of those reference tags. The experimental results show that this system can realize the positioning function of forklift, and it can be used in practical situations.

  1. Enhanced Freshwater Production Using Finned-Plate Air Gap Membrane Distillation (AGMD

    Directory of Open Access Journals (Sweden)

    Perves Bappy Mohammad Jabed

    2017-01-01

    Full Text Available Air Gap membrane distillation (AGMD, a special type of energy efficient membrane distillation process, is a technology for producing freshwater from waste water. Having some benefits over other traditional processes, this method has been able to draw attention of researchers working in the field of freshwater production technologies. In this study, a basic AGMD system with flat coolant plate has been modified using a specially designed channelled coolant plate of portable size to observe its effect over the production rate and performance of the system. Attempt has been made to increase the amount of distillate flux by using the “fin effect” of the channelled coolant plate. A finned plate have been used instead of a flat coolant plate and experiments were conducted to compare the effect. Coolant temperature and feed temperature of the system have been varied from 10°C to 25°C and 40°C to 70°C respectively. Comparing the data, around 50% to 58% distillate enhancement has been observed for channelled coolant plate. Also, it was seen that the enhancement was higher for higher feed temperatures and coolant temperatures. With these findings, a better performing AGMD module has been introduced to mitigate the scarcity of freshwater.

  2. Cost/benefit analysis of electronic license plates

    Science.gov (United States)

    2008-06-01

    The objective of this report is to determine whether electronic vehicle recognition systems (EVR) or automatic license plate recognition systems (ALPR) would be beneficial to the Arizona Department of Transportation (AZDOT). EVR uses radio frequency ...

  3. Measuring the Reader Self-Perceptions of Adolescents: Introducing the RSPS2

    Science.gov (United States)

    Henk, William A.; Marinak, Barbara A.; Melnick, Steven A.

    2013-01-01

    This paper introduces a new affective instrument for assessing the reader self-perceptions of students in grades seven through ten. The Reader Self-Perception Scale 2 (RSPS2) builds upon its predecessor, the RSPS, a tool that measures the reading efficacy beliefs of children in grades four through six. New items were created for the RSPS2 to…

  4. Guiding Young Readers to Multicultural Literature

    Science.gov (United States)

    Hinton-Johnson, KaaVonia; Dickinson, Gail

    2005-01-01

    Stocking the shelves of library media centers with multicultural literature is not enough, it is important that children are helped to choose the ones that would interest them as reading about various cultures is of great benefit to young readers. The importance of accurately representing to children a multicultural society is emphasized and…

  5. Parity generator and parity checker in the modified trinary number system using savart plate and spatial light modulator

    Science.gov (United States)

    Ghosh, Amal K.

    2010-09-01

    The parity generators and the checkers are the most important circuits in communication systems. With the development of multi-valued logic (MVL), the proposed system with parity generators and checkers is the most required using the recently developed optoelectronic technology in the modified trinary number (MTN) system. This system also meets up the tremendous needs of speeds by exploiting the savart plates and spatial light modulators (SLM) in the optical tree architecture (OTA).

  6. Scale-up of Carbon/Carbon Bipolar Plates

    Energy Technology Data Exchange (ETDEWEB)

    David P. Haack

    2009-04-08

    This project was focused upon developing a unique material technology for use in PEM fuel cell bipolar plates. The carbon/carbon composite material developed in this program is uniquely suited for use in fuel cell systems, as it is lightweight, highly conductive and corrosion resistant. The project further focused upon developing the manufacturing methodology to cost-effectively produce this material for use in commercial fuel cell systems. United Technology Fuel Cells Corp., a leading fuel cell developer was a subcontractor to the project was interested in the performance and low-cost potential of the material. The accomplishments of the program included the development and testing of a low-cost, fully molded, net-shape carbon-carbon bipolar plate. The process to cost-effectively manufacture these carbon-carbon bipolar plates was focused on extensively in this program. Key areas for cost-reduction that received attention in this program was net-shape molding of the detailed flow structures according to end-user design. Correlations between feature detail and process parameters were formed so that mold tooling could be accurately designed to meet a variety of flow field dimensions. A cost model was developed that predicted the cost of manufacture for the product in near-term volumes and long-term volumes (10+ million units per year). Because the roduct uses lowcost raw materials in quantities that are less than competitive tech, it was found that the cost of the product in high volume can be less than with other plate echnologies, and can meet the DOE goal of $4/kW for transportation applications. The excellent performance of the all-carbon plate in net shape was verified in fuel cell testing. Performance equivalent to much higher cost, fully machined graphite plates was found.

  7. Medically relevant assays with a simple smartphone and tablet based fluorescence detection system.

    Science.gov (United States)

    Wargocki, Piotr; Deng, Wei; Anwer, Ayad G; Goldys, Ewa M

    2015-05-20

    Cell phones and smart phones can be reconfigured as biomedical sensor devices but this requires specialized add-ons. In this paper we present a simple cell phone-based portable bioassay platform, which can be used with fluorescent assays in solution. The system consists of a tablet, a polarizer, a smart phone (camera) and a box that provides dark readout conditions. The assay in a well plate is placed on the tablet screen acting as an excitation source. A polarizer on top of the well plate separates excitation light from assay fluorescence emission enabling assay readout with a smartphone camera. The assay result is obtained by analysing the intensity of image pixels in an appropriate colour channel. With this device we carried out two assays, for collagenase and trypsin using fluorescein as the detected fluorophore. The results of collagenase assay with the lowest measured concentration of 3.75 µg/mL and 0.938 µg in total in the sample were comparable to those obtained by a microplate reader. The lowest measured amount of trypsin was 930 pg, which is comparable to the low detection limit of 400 pg for this assay obtained in a microplate reader. The device is sensitive enough to be used in point-of-care medical diagnostics of clinically relevant conditions, including arthritis, cystic fibrosis and acute pancreatitis.

  8. Medically Relevant Assays with a Simple Smartphone and Tablet Based Fluorescence Detection System

    Directory of Open Access Journals (Sweden)

    Piotr Wargocki

    2015-05-01

    Full Text Available Cell phones and smart phones can be reconfigured as biomedical sensor devices but this requires specialized add-ons. In this paper we present a simple cell phone-based portable bioassay platform, which can be used with fluorescent assays in solution. The system consists of a tablet, a polarizer, a smart phone (camera and a box that provides dark readout conditions. The assay in a well plate is placed on the tablet screen acting as an excitation source. A polarizer on top of the well plate separates excitation light from assay fluorescence emission enabling assay readout with a smartphone camera. The assay result is obtained by analysing the intensity of image pixels in an appropriate colour channel. With this device we carried out two assays, for collagenase and trypsin using fluorescein as the detected fluorophore. The results of collagenase assay with the lowest measured concentration of 3.75 µg/mL and 0.938 µg in total in the sample were comparable to those obtained by a microplate reader. The lowest measured amount of trypsin was 930 pg, which is comparable to the low detection limit of 400 pg for this assay obtained in a microplate reader. The device is sensitive enough to be used in point-of-care medical diagnostics of clinically relevant conditions, including arthritis, cystic fibrosis and acute pancreatitis.

  9. Investigation of one-dimensional heat flow in a solarflat plate collector with sun tracing system

    Directory of Open Access Journals (Sweden)

    H Samimi Akhijahani

    2016-09-01

    variation of total heat flow over the time at different surfaces of the collector is determined by using equation 3: 3 Two cases (solar panel with rotation and without rotation were considered for testing. Data measuring was carried out for 9 hours from 8 to 17. The fluid flow rate was 0.0185m3.s-1. The dryer was installed in an environment with air temperature of 31.6 oC and 31.8 oC, with the air velocity of 0.58 m.s-1 and 0.54 m.s-1 and with the relative air humidity of about 21%and 21.5% at the first and second days, respectively. The dryer had an automatic temperature controller to fix the air temperature with an accuracy of ±0.1 oC. An anemometer Yk-2005AM model was used to regulate the required air velocity. The output data of the thermocouples was recorded by a digital thermometer (DL-9601A, Lutron that was connected to a computer using RS232 cable and recorded the temperature at required point every an hour. The relative humidity of the ambient was measured every hour with a digital hygrometer (HT.3600, Taiwan, accuracy of 3%. By assembling controlling system with a DC motor, a precious photocell and a proper mechanism, the frame would rotate by the sun and followed solar radiation, therefore more solar energy produced in solar panel. Results and Discussion The results of the experiments showed that the heat transfer process increased in both cases from the early morning and reached to its maximum value around 12 to 14 o’clock. The trend was more homogeneous in the dryer by absorber plate without rotation due to the decline of the heat accumulation. The mean temperature rise in the solar dryer without rotation was 37oC and in the solar dryer with rotation was 54oC. Because of the rotation of solar plate, variations of solar radiation were low. Therefore, by rotation of the solar dryer panel the temperature rise was 27oC. The values of heat transfer coefficient in the solar dryer with rotation were decreased by the time. This reduction in the hours before noon is

  10. Open Channel Natural Convection Heat Transfer on a Vertical Finned Plate

    International Nuclear Information System (INIS)

    Park, Joo Hyun; Heo, Jeong Hwan; Chung, Bum Jin

    2013-01-01

    The natural convection heat transfer of vertical plate fin was investigated experimentally. Heat transfer systems were replaced by mass-transfer systems, based on the analogy concept. The experimental results lie within the predictions of the existing heat transfer correlations of plate-fin for the natural convections. An overlapped thermal boundary layers caused increasing heat transfer, and an overlapped momentum boundary layers caused decreasing heat transfer. As the fin height increases, heat transfer was enhanced due to increased inflow from the open side of the fin spacing. When fin spacing and fin height are large, heat transfer was unaffected by the fin spacing and fin height. Passive cooling by natural convection becomes more and more important for the nuclear systems as the station black out really happened at the Fukushima NPPs. In the RCCS (Reactor Cavity Cooling System) of a VHTR (Very High Temperature Reactor), natural convection cooling through duct system is adopted. In response to the stack failure event, extra cooling capacity adopting the fin array has to be investigated. The finned plate increases the surface area and the heat transfer increases. However, the plate of fin arrays may increase the pressure drop and the heat transfer decreases. Therefore, in order to enhance the passive cooling with fin arrays, the parameters for the fin arrays should be optimized. According to Welling and Wooldridge, a natural convection on vertical plate fin is function of Gr, Pr, L, t, S, and H. The present work investigated the natural convection heat transfer of a vertical finned plate with varying the fin height and the fin spacing. In order achieve high Rayleigh numbers, an electroplating system was employed and the mass transfer rates were measured using a copper sulfate electroplating system based on the analogy concept

  11. Finite element analysis of a solar collector plate using two plate geometries

    Directory of Open Access Journals (Sweden)

    Diego Manuel Medina Carril

    2016-09-01

    Full Text Available The thermal behavior of an absorber plate in a solar collector is investigated using finite element analysis. The thermal behavior and efficiency of two absorber plate geometries are studied, using a typical solar collector with a rectangular profile as reference, and a proposed absorber plate with curved geometry. An analysis of the most important parameters involved in the design of the absorber plate was carried out, indicating that the curved geometry of the absorber plate yields an average efficiency ~25% higher than the conventional rectangular geometry. The results suggest that a curved profile made of materials such as aluminum with thermal conductivity higher than 200W/m°C, plate thickness of the order of 2-3mm and with a large density of tubes per unit area of the collector´s plate greatly benefits the thermal efficiency of the solar collector.

  12. Vibrotactile masking experiments reveal accelerated somatosensory processing in congenitally blind braille readers.

    Science.gov (United States)

    Bhattacharjee, Arindam; Ye, Amanda J; Lisak, Joy A; Vargas, Maria G; Goldreich, Daniel

    2010-10-27

    Braille reading is a demanding task that requires the identification of rapidly varying tactile patterns. During proficient reading, neighboring characters impact the fingertip at ∼100 ms intervals, and adjacent raised dots within a character at 50 ms intervals. Because the brain requires time to interpret afferent sensorineural activity, among other reasons, tactile stimuli separated by such short temporal intervals pose a challenge to perception. How, then, do proficient Braille readers successfully interpret inputs arising from their fingertips at such rapid rates? We hypothesized that somatosensory perceptual consolidation occurs more rapidly in proficient Braille readers. If so, Braille readers should outperform sighted participants on masking tasks, which demand rapid perceptual processing, but would not necessarily outperform the sighted on tests of simple vibrotactile sensitivity. To investigate, we conducted two-interval forced-choice vibrotactile detection, amplitude discrimination, and masking tasks on the index fingertips of 89 sighted and 57 profoundly blind humans. Sighted and blind participants had similar unmasked detection (25 ms target tap) and amplitude discrimination (compared with 100 μm reference tap) thresholds, but congenitally blind Braille readers, the fastest readers among the blind participants, exhibited significantly less masking than the sighted (masker, 50 Hz, 50 μm; target-masker delays, ±50 and ±100 ms). Indeed, Braille reading speed correlated significantly and specifically with masking task performance, and in particular with the backward masking decay time constant. We conclude that vibrotactile sensitivity is unchanged but that perceptual processing is accelerated in congenitally blind Braille readers.

  13. BEPLATE emdash simulation of electrochemical plating

    Energy Technology Data Exchange (ETDEWEB)

    Giles, G.E. (Oak Ridge K-25 Site, TN (USA)); Gray, L.J. (Oak Ridge National Lab., TN (USA)); Bullock, J.S. IV (Oak Ridge Y-12 Plant, TN (USA))

    1990-09-01

    BEPLATE is a FORTRAN code that uses the boundary element method to simulate the electrochemical plating of material on parts, primarily rotating axisymmetric parts. A boundary element technique is used to solve for the local current density and thus the plating rate on the part, which is used to calculate the growth in the plated layer over a user-specified time step. The surface is moved to reflect this growth, and the new surface is used to generate the local current density. This cycle is repeated until the final time specified by the analyst, producing the final plated thickness. BEPLATE includes models for the polarization effects at both the part (cathode) and anode and allows the use of symmetry planes and nonconducting shields. For electroplating simulations, the part shape is normally assumed to be axisymmetric with a centerline along the z-axis. More general part shapes can be analyzed by BEPLATE if the surface growth simulation is not needed. In either case, the shield, anode, and tank geometries are not restricted to specific shapes. This report includes the information required to run BEPLATE, specifically, a brief description of the BEPLATE system including hardware and software requirements, a description of the complete simulation process, discussion of rules for generating models, and additional reference material. This system of codes consists of model generators (PIGS or PATRAN), input processor (BEPIN), the simulation code (BEPLATE) and postprocessing codes (PATRAN or CONPLOT).

  14. Capacity of the circular plate condenser: analytical solutions for large gaps between the plates

    International Nuclear Information System (INIS)

    Rao, T V

    2005-01-01

    A solution of Love's integral equation (Love E R 1949 Q. J. Mech. Appl. Math. 2 428), which forms the basis for the analysis of the electrostatic field due to two equal circular co-axial parallel conducting plates, is considered for the case when the ratio, τ, of distance of separation to radius of the plates is greater than 2. The kernel of the integral equation is expanded into an infinite series in odd powers of 1/τ and an approximate kernel accurate to O(τ -(2N+1) ) is deduced therefrom by terminating the series after an arbitrary but finite number of terms, N. The approximate kernel is rearranged into a degenerate form and the integral equation with this kernel is reduced to a system of N linear equations. An explicit analytical solution is obtained for N = 4 and the resulting analytical expression for the capacity of the circular plate condenser is shown to be accurate to O(τ -9 ). Analytical expressions of lower orders of accuracy with respect to 1/τ are deduced from the four-term (i.e., N 4) solution and predictions (of capacity) from the expressions of different orders of accuracy (with respect to 1/τ) are compared with very accurate numerical solutions obtained by solving the linear system for large enough N. It is shown that the O(τ -9 ) approximation predicts the capacity extremely well for any τ ≥ 2 and an O(τ -3 ) approximation gives, for all practical purposes, results of adequate accuracy for τ ≥ 4. It is further shown that an approximate solution, applicable for the case of large distances of separation between the plates, due to Sneddon (Sneddon I N 1966 Mixed Boundary Value Problems in Potential Theory (Amsterdam: North-Holland) pp 230-46) is accurate to O(τ -6 ) for τ ≥ 2

  15. Investigation of the decolorization efficiency of two pin-to-plate corona discharge plasma system for industrial wastewater treatment

    Energy Technology Data Exchange (ETDEWEB)

    El-Tayeb, A., E-mail: ahmed.khalil@ejust.edu.eg; El-Shazly, A. H.; Elkady, M. F. [Egypt−Japan University of Science and Technology, Chemicals and Petrochemicals Engineering Department (Egypt); Abdel-Rahman, A. B. [Egypt−Japan University of Science and Technology, Electronics and Communications Engineering Department (Egypt)

    2016-09-15

    In this article, a dual pin-to-plate high-voltage corona discharge system is introduced to study experimentally the gap distance, the contact time, the effect of pin and plate materials, the thickness of ground plate and the conductivity on the amount of Acid Blue 25 dye color removal efficiency from polluted water. A study for the optimum air gap distance between dual pin and surface of Acid Blue 25 dye solution is carried out using 3D-EM simulator to find maximum electric field intensity at the tip of both pins. The outcomes display that the best gap for corona discharge is approximately 5 mm for 15-kV source. This separation is constant during the study of other factors. In addition, an investigation of the essential reactive species responsible for oxidation of the dye organic compounds (O{sub 3} in air discharge, O{sub 3} in water, and H{sub 2}O{sub 2}) during the experimental time is conducted. Three various materials such as: stainless steel, copper and aluminum are used for pins and plate. The maximum color removal efficiencies of Acid Blue 25 dyes are 99.03, 82.04, and 90.78% after treatment time 15 min for stainless steel, copper, and aluminum, respectively. Measurement results for the impact of thickness of an aluminum ground plate on color removal competence show color removal efficiencies of 86.3, 90.78, and 98.06% after treatment time 15 min for thicknesses of 2, 0.5, and 0.1 mm, respectively. The increasing of the solution conductivity leads to the reduction of decolorization efficiency. A kinetic model is used to define the performance of corona discharge system. The models of pseudo-zero-order, pseudo-first-order, and pseudo-second-order reaction kinetics are utilized to investigate the decolorization of Acid Blue 25 dye. The rate of degradation of Acid Blue 25 dye follows the pseudo-first-order kinetics in the dye concentration.

  16. Investigation of the decolorization efficiency of two pin-to-plate corona discharge plasma system for industrial wastewater treatment

    International Nuclear Information System (INIS)

    El-Tayeb, A.; El-Shazly, A. H.; Elkady, M. F.; Abdel-Rahman, A. B.

    2016-01-01

    In this article, a dual pin-to-plate high-voltage corona discharge system is introduced to study experimentally the gap distance, the contact time, the effect of pin and plate materials, the thickness of ground plate and the conductivity on the amount of Acid Blue 25 dye color removal efficiency from polluted water. A study for the optimum air gap distance between dual pin and surface of Acid Blue 25 dye solution is carried out using 3D-EM simulator to find maximum electric field intensity at the tip of both pins. The outcomes display that the best gap for corona discharge is approximately 5 mm for 15-kV source. This separation is constant during the study of other factors. In addition, an investigation of the essential reactive species responsible for oxidation of the dye organic compounds (O 3 in air discharge, O 3 in water, and H 2 O 2 ) during the experimental time is conducted. Three various materials such as: stainless steel, copper and aluminum are used for pins and plate. The maximum color removal efficiencies of Acid Blue 25 dyes are 99.03, 82.04, and 90.78% after treatment time 15 min for stainless steel, copper, and aluminum, respectively. Measurement results for the impact of thickness of an aluminum ground plate on color removal competence show color removal efficiencies of 86.3, 90.78, and 98.06% after treatment time 15 min for thicknesses of 2, 0.5, and 0.1 mm, respectively. The increasing of the solution conductivity leads to the reduction of decolorization efficiency. A kinetic model is used to define the performance of corona discharge system. The models of pseudo-zero-order, pseudo-first-order, and pseudo-second-order reaction kinetics are utilized to investigate the decolorization of Acid Blue 25 dye. The rate of degradation of Acid Blue 25 dye follows the pseudo-first-order kinetics in the dye concentration.

  17. Phosphor plate mammography: contrast studies and clinical experience

    International Nuclear Information System (INIS)

    Chang, C.H.J.; Martin, N.L.; Templeton, A.W.; Cook, L.T.; Harrison, L.A.; McFadden, M.A.; Dwyer, S.J. III; Spicer, J.; Crystal, J.M.

    1992-01-01

    Mammography and accurate microcalcification detection require very good spatial resolution. We have compared the diagnostic capabilities of reduced-exposure, third-generation, 5 cycles/mm computed radiography (CR) phosphor plates with conventional screen-film in 67 patients. No difference in diagnostic accuracy was detected. The digital characteristics of storage phosphor plates erabled us to study the relationship between contrast and spatial resolution. We developed a computer program to identify a single 100 μm pixel in a digital image and assign various gray levels to that pixel. Using this model, we determined that, for our 5 cycles/mm CR system, the imaged contrast of a 100 μm object was 62% of the original contrast. Current 5 cycles/mm phosphor plate systems cannot adequately detect microcalcifications that approximate 100 μm or smaller unless a magnification technique is used. (orig.)

  18. Management of pediatric mandibular fractures using bioresorbable plating system – Efficacy, stability, and clinical outcomes: Our experiences and literature review

    Science.gov (United States)

    Singh, Mahinder; Singh, R.K.; Passi, Deepak; Aggarwal, Mohit; Kaur, Guneet

    2015-01-01

    Aims The purpose of this study was to determine the efficacy and stability of the biodegradable fixation system for treatment of mandible fractures in pediatric patients by measuring the bite force. Methods Sixty pediatric patients with mandibular fractures (36 males, 24 females) were included in this study. The 2.5-mm resorbable plates were adapted along Champy's line of ideal osteosynthesis and secured with four 2.5 mm diameter monocortical resorbable screws, 8 mm in length. All patients were followed for 10 months. Clinical parameters, such as soft tissue infection, nonunion, malunion, implant exposure, malocclusion, nerve injury, and bite force for stability, were prospectively assessed. Results Adequate fixation and primary bone healing was achieved in 100% of the cases. Six minor complications (10%) were observed: 2 soft tissue infections (3%), 1 plate dehiscence (2%), 1 malocclusion (2%), and 2 paresthesia (3%). Conclusion 2.5-mm resorbable plating system along Champy's line of ideal osteosynthesis is a good treatment modality for mandible fractures in pediatric patients. PMID:27195206

  19. Trochanteric Fixation With a Third-Generation Cable-Plate System: An Independent Experience.

    Science.gov (United States)

    Stewart, Andrew D; Abdelbary, Hesham; Beaulé, Paul E

    2017-09-01

    Greater trochanteric fracture/nonunion can be a devastating complication with significant functional impact after total hip arthroplasty, and their fixation remains a challenge because of the significant forces being transmitted as well as the poor bone quality often associated with these fractures. The objective of this study is to investigate the rates of reoperation and trochanteric nonunion using a third-generation cable-plate system at one center. Thirty-five patients, mean age 72.9 years (range 46-98 years) with 24 women and 11 men, underwent fixation of their fractured greater trochanter using a third-generation cable-plate system. The indications were: periprosthetic fracture (n = 17), complex primary arthroplasty (n = 5), and complex revision arthroplasty (n = 13). Primary outcomes included rates of reoperation and radiographic union. At a mean follow-up of 2.5 years, trochanteric union rate was 62.9% with nonunion rate of 31.4%, and fibrous union in 5.7%. In regard to quality of initial apposition, only 40% achieved a perfect bone on bone reduction. Ten patients (28.6%) had evidence of wire breakage. Five patients (14.3%) required reoperation and removal of the internal fixation because of lateral hip pain. Fixation of the trochanteric fractures remains a challenge with a relatively high reoperation rate. Poor bone quality and capacity to maintain a stable reduction continue to make this complication after total hip arthroplasty a difficult problem to solve. Copyright © 2017. Published by Elsevier Inc.

  20. Collaboration between SSMJ and its readers

    African Journals Online (AJOL)

    All of us in the healthcare professions throughout the world can learn much from each other. This has been demonstrated so well by the collaboration between the editors, authors, medical experts and readers of the South Sudan Medical Journal. The Editor-in-Chief recently sent out a request for photographs and received a ...

  1. Rights of Postsecondary Readers and Learners

    Science.gov (United States)

    Greenbaum, JoAnne; Angus, Kathryn Bartle

    2018-01-01

    A position statement on the rights of adult readers and learners was adopted by the CRLA board in 2002 and published with a theoretical rationale in ["Journal of College Reading and Learning"] "JCRL," Spring 2003. The statement was a guideline for educators seeking to improve the quality of adult education. In 2016, at the…

  2. Plate removal following orthognathic surgery.

    Science.gov (United States)

    Little, Mhairi; Langford, Richard Julian; Bhanji, Adam; Farr, David

    2015-11-01

    The objectives of this study are to determine the removal rates of orthognathic plates used during orthognathic surgery at James Cook University Hospital and describe the reasons for plate removal. 202 consecutive orthognathic cases were identified between July 2004 and July 2012. Demographics and procedure details were collected for these patients. Patients from this group who returned to theatre for plate removal between July 2004 and November 2012 were identified and their notes were analysed for data including reason for plate removal, age, smoking status, sex and time to plate removal. 3.2% of plates were removed with proportionally more plates removed from the mandible than the maxilla. 10.4% of patients required removal of one or more plate. Most plates were removed within the first post-operative year. The commonest reasons for plate removal were plate exposure and infection. The plate removal rates in our study are comparable to those seen in the literature. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  3. Concurrent Validity of a Portable Force Plate Using Vertical Jump Force-Time Characteristics.

    Science.gov (United States)

    Lake, Jason; Mundy, Peter; Comfort, Paul; McMahon, John J; Suchomel, Timothy J; Carden, Patrick

    2018-05-29

    This study examined concurrent validity of countermovement vertical jump (CMJ) reactive strength index modified and force-time characteristics recorded using a one dimensional portable and laboratory force plate system. Twenty-eight men performed bilateral CMJs on two portable force plates placed on top of two in-ground force plates, both recording vertical ground reaction force at 1000 Hz. Time to take-off, jump height, reactive strength index modified, braking and propulsion impulse, mean net force, and duration were calculated from the vertical force from both force plate systems. Results from both systems were highly correlated (r≥.99). There were small (dbraking impulse, braking mean net force, propulsion impulse, and propulsion mean net force (psystem (95% CL: .9% to 2.5%), indicating very good agreement across all of the dependent variables. The largest limits of agreement belonged to jump height (2.1%), time to take-off (3.4%), and reactive strength index modified (3.8%). The portable force plate system provides a valid method of obtaining reactive strength measures, and several underpinning force-time variables, from unloaded CMJ and practitioners can use both force plates interchangeably.

  4. Ultra-wideband ladder filters using zero-th shear mode plate wave in ultrathin LiNbO3 plate with apodized interdigital transducers

    Science.gov (United States)

    Kadota, Michio; Tanaka, Shuji

    2016-07-01

    There are two kinds of plate waves propagating in a thin plate, Lamb and shear horizontal (SH) waves. The former has a velocity higher than 15,000 m/s when the plate is very thin. On the contrary, 0th SH (SH0) mode plate wave in an ultrathin LiNbO3 plate has an electro-mechanical coupling factor larger than 50%. Authors fabricated an ultra-wideband T-type ladder filter with a relative bandwidth (BW) of 41% using the SH0 mode plate wave. Although the BW of the filter fully covers the digital TV band in Japan, it does not have sufficient margin at the lower and higher end of BW. Besides, periodic small ripples due to transverse mode in pass-band of the filter were observed. In this study π-type ladder filters were fabricated by changing the pitch ratio of interdigital transducer (IDT) of parallel and series arm resonators (PR(IDT)) to control the BW, and by apodizing IDTs to improve the periodic small ripples due to transverse mode. Ultra-wideband filters without periodic small transverse mode with ultrawide bandwidth from 41 to 49% were fabricated. The BWs fully cover ultrawide digital television bands in Japan and U.S.A. These filters with an ultrawide BW and a steep characteristic show the possibility to be applied to a reported cognitive radio system and other communication systems requiring an ultrawide BW.

  5. A digital reader for condenser ionization chambers

    International Nuclear Information System (INIS)

    Stuermer, K.

    1978-01-01

    A reader for condenser chambers is described which has a completely automatic reading/charging operation, a modern digital readout presentation, and two full decades of exposure readout for each dosimeter type. The calibration and operation of the instrument are given

  6. Glycan Reader is improved to recognize most sugar types and chemical modifications in the Protein Data Bank.

    Science.gov (United States)

    Park, Sang-Jun; Lee, Jumin; Patel, Dhilon S; Ma, Hongjing; Lee, Hui Sun; Jo, Sunhwan; Im, Wonpil

    2017-10-01

    Glycans play a central role in many essential biological processes. Glycan Reader was originally developed to simplify the reading of Protein Data Bank (PDB) files containing glycans through the automatic detection and annotation of sugars and glycosidic linkages between sugar units and to proteins, all based on atomic coordinates and connectivity information. Carbohydrates can have various chemical modifications at different positions, making their chemical space much diverse. Unfortunately, current PDB files do not provide exact annotations for most carbohydrate derivatives and more than 50% of PDB glycan chains have at least one carbohydrate derivative that could not be correctly recognized by the original Glycan Reader. Glycan Reader has been improved and now identifies most sugar types and chemical modifications (including various glycolipids) in the PDB, and both PDB and PDBx/mmCIF formats are supported. CHARMM-GUI Glycan Reader is updated to generate the simulation system and input of various glycoconjugates with most sugar types and chemical modifications. It also offers a new functionality to edit the glycan structures through addition/deletion/modification of glycosylation types, sugar types, chemical modifications, glycosidic linkages, and anomeric states. The simulation system and input files can be used for CHARMM, NAMD, GROMACS, AMBER, GENESIS, LAMMPS, Desmond, OpenMM, and CHARMM/OpenMM. Glycan Fragment Database in GlycanStructure.Org is also updated to provide an intuitive glycan sequence search tool for complex glycan structures with various chemical modifications in the PDB. http://www.charmm-gui.org/input/glycan and http://www.glycanstructure.org. wonpil@lehigh.edu. Supplementary data are available at Bioinformatics online. © The Author (2017). Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  7. Experimental investigations of image quality in X-ray mammography with conventional screen film system (SFS), digital phosphor storage plate in/without magnification technique (CR) and digital CCD-technique (CCD)

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Aichinger, U.; Boehner, C.; Dobritz, M.; Wenkel, E.; Bautz, W.; Saebel, M.

    2001-01-01

    Comparison of image quality in X-ray mammography between conventional film screen film system (SFS), digital phosphor storage plate in and without magnification technique (CR) and digital CCD-technique (CCD). Radiograms of an RMI-mammography phantom were acquired using a conventional screen film system, three digital storage plate systems and two digital systems in CCD-technique. Additionally the radiograms of one digital phosphor storage plate system were post-processed regarding contrast and included in the comparison. The detectability of details was best with the digital mammography in CCD-technique. After confirming these promising results in clinical studies, digital mammography should be able to replace conventional screen film technique. (orig.)

  8. News in online and print newspapers: Differences in reader consumption and recall

    NARCIS (Netherlands)

    d'Haenens, Leen; Jankowski, Nicholas; Heuvelman, A.

    2004-01-01

    How readers consume and recall news presented in online and print versions of two newspapersin the Netherlands are investigated in this experimental study. Few differences are found between the online and print versions in terms of news supply. Reader attention to the news stories varies, depending

  9. A License Plate Locating Method Based on Tophat-bothat Changing and Line Scanning

    International Nuclear Information System (INIS)

    Hou, P G; Zhao, J; Liu, M

    2006-01-01

    The automatic license plate recognition is an important technique to obtain traffic information, it mixes computer vision, image processing techniques and pattern recognition techniques, it is an important technique in intelligent traffic system. In a vehicle license plate recognition system, plate region detection is the key step before the final recognition. This article introduces the whole process of plate region detection. Top - hat and bot - hat transformation are used for enhancing the image contrast in this paper, and wavelet threshold method is used as image filter, and a improved line scanning is used for plate region detection at last. This method has strong practicability. The experimental results demonstrate that the method introduced in this paper is effective

  10. A multi-component parallel-plate flow chamber system for studying the effect of exercise-induced wall shear stress on endothelial cells.

    Science.gov (United States)

    Wang, Yan-Xia; Xiang, Cheng; Liu, Bo; Zhu, Yong; Luan, Yong; Liu, Shu-Tian; Qin, Kai-Rong

    2016-12-28

    In vivo studies have demonstrated that reasonable exercise training can improve endothelial function. To confirm the key role of wall shear stress induced by exercise on endothelial cells, and to understand how wall shear stress affects the structure and the function of endothelial cells, it is crucial to design and fabricate an in vitro multi-component parallel-plate flow chamber system which can closely replicate exercise-induced wall shear stress waveforms in artery. The in vivo wall shear stress waveforms from the common carotid artery of a healthy volunteer in resting and immediately after 30 min acute aerobic cycling exercise were first calculated by measuring the inner diameter and the center-line blood flow velocity with a color Doppler ultrasound. According to the above in vivo wall shear stress waveforms, we designed and fabricated a parallel-plate flow chamber system with appropriate components based on a lumped parameter hemodynamics model. To validate the feasibility of this system, human umbilical vein endothelial cells (HUVECs) line were cultured within the parallel-plate flow chamber under abovementioned two types of wall shear stress waveforms and the intracellular actin microfilaments and nitric oxide (NO) production level were evaluated using fluorescence microscope. Our results show that the trends of resting and exercise-induced wall shear stress waveforms, especially the maximal, minimal and mean wall shear stress as well as oscillatory shear index, generated by the parallel-plate flow chamber system are similar to those acquired from the common carotid artery. In addition, the cellular experiments demonstrate that the actin microfilaments and the production of NO within cells exposed to the two different wall shear stress waveforms exhibit different dynamic behaviors; there are larger numbers of actin microfilaments and higher level NO in cells exposed in exercise-induced wall shear stress condition than resting wall shear stress condition

  11. [Impact on reading scientific articles:an attempt to dialogue with "my reader"].

    Science.gov (United States)

    Akerman, Marco

    2016-03-01

    This article discusses the concept of "impact" and is based on the scientific output of the author that is examined for the analysis of impacts from the qualitative standpoint. It is done not as an end in itself, but under the aegis of the author/text/reader relationship. Seeking to establish this relationship, the way in which the author is quoted in a selected article, entering each of the quotes and identifying what aspects were emphasized by the readers who referenced the quote is explored in detail. This qualitative observation of each of the quotes provided an indication of how each author/reader perceived the original text. This personal experience of this finite and delicate dialogue with "my reader" is presented here as a recommendation, to anyone who may be interested, of a viable device that can be repeated by authors in order to re-visit their writings based on the acknowledgement of the impact that it has on others.

  12. The role of 3D plating system in mandibular fractures: A prospective study

    Directory of Open Access Journals (Sweden)

    Rajendra Prasad

    2013-01-01

    Full Text Available Aim: The aim of our study was to evaluate the advantages and disadvantages of 3D plating system in the treatment of mandibular fractures. Patients and Methods: 20 mandibular fractures in 18 patients at various anatomic locations and were treated by open reduction and internal fixation using 3D plates. All patients were followed at regular intervals of 4 th , 8 th and 12 th weeks respectively. Patients were assessed post-operatively for lingual splay and occlusal stability. The incidence of neurosensory deficit, infection, masticatory difficulty, non-union, malunion was also assessed. Results: A significant reduction in lingual splay (72.2% and occlusal stability (72.2% was seen. The overall complication rate was (16.6% which included two patients who developed post-operative paresthesia of lip, three patients had infection and two cases of masticatory difficulty which later subsided by higher antibiotics and 4 weeks of MMF. No evidence of non-union, malunion was noted. Conclusion: A single 3D 2 mm miniplate with 2 mm × 8 mm screws is a reliable and an effective treatment modality for mandibular fracture.

  13. Is Active Tectonics on Madagascar Consistent with Somalian Plate Kinematics?

    Science.gov (United States)

    Stamps, D. S.; Kreemer, C.; Rajaonarison, T. A.

    2017-12-01

    The East African Rift System (EARS) actively breaks apart the Nubian and Somalian tectonic plates. Madagascar finds itself at the easternmost boundary of the EARS, between the Rovuma block, Lwandle plate, and the Somalian plate. Earthquake focal mechanisms and N-S oriented fault structures on the continental island suggest that Madagascar is experiencing east-west oriented extension. However, some previous plate kinematic studies indicate minor compressional strains across Madagascar. This inconsistency may be due to uncertainties in Somalian plate rotation. Past estimates of the rotation of the Somalian plate suffered from a poor coverage of GPS stations, but some important new stations are now available for a re-evaluation. In this work, we revise the kinematics of the Somalian plate. We first calculate a new GPS velocity solution and perform block kinematic modeling to evaluate the Somalian plate rotation. We then estimate new Somalia-Rovuma and Somalia-Lwandle relative motions across Madagascar and evaluate whether they are consistent with GPS measurements made on the island itself, as well as with other kinematic indicators.

  14. Bending and stretching of plates

    CERN Document Server

    Mansfield, E H; Hemp, W S

    1964-01-01

    The Bending and Stretching of Plates deals with elastic plate theory, particularly on small- and large-deflexion theory. Small-deflexion theory concerns derivation of basic equations, rectangular plates, plates of various shapes, plates whose boundaries are amenable to conformal transformation, plates with variable rigidity, and approximate methods. Large-deflexion theory includes general equations and some exact solutions, approximate methods in large-deflexion theory, asymptotic large-deflexion theories for very thin plates. Asymptotic theories covers membrane theory, tension field theory, a

  15. Plate with a hole obeys the averaged null energy condition

    International Nuclear Information System (INIS)

    Graham, Noah; Olum, Ken D.

    2005-01-01

    The negative energy density of Casimir systems appears to violate general relativity energy conditions. However, one cannot test the averaged null energy condition (ANEC) using standard calculations for perfectly reflecting plates, because the null geodesic would have to pass through the plates, where the calculation breaks down. To avoid this problem, we compute the contribution to ANEC for a geodesic that passes through a hole in a single plate. We consider both Dirichlet and Neumann boundary conditions in two and three space dimensions. We use a Babinet's principle argument to reduce the problem to a complementary finite disk correction to the perfect mirror result, which we then compute using scattering theory in elliptical and spheroidal coordinates. In the Dirichlet case, we find that the positive correction due to the hole overwhelms the negative contribution of the infinite plate. In the Neumann case, where the infinite plate gives a positive contribution, the hole contribution is smaller in magnitude, so again ANEC is obeyed. These results can be extended to the case of two plates in the limits of large and small hole radii. This system thus provides another example of a situation where ANEC turns out to be obeyed when one might expect it to be violated

  16. The Role of Reader in Felpo Filva, by Eva Furnari

    Directory of Open Access Journals (Sweden)

    Ana Elvira L. Gebara

    2017-10-01

    Full Text Available In order to analyze the relationship between writer-reader and mediation of the text, it is necessary to identify the positions they occupy. Before the Internet, it was not common for the reader to approach the writer directly, except though letters. This virtual (but not digital contact is modelling to understand the reader’s relationship with the author because, in the written lines, he ends up indicating how he understands himself and the other – in a game of faces, understood in this work as Kerbrat-Orecchioni (2006 it characterizes in conversation. In this hyper-gender, without socio-historical restrictions or of categorization (MAINGUENEAU, 2010, there is a mandatory provision that constrains the sender to identify his position from the moment he chooses how to address the recipient. In these forms of treatment, the relationships of preservation or threat to the in the light of what is extended or made explicit in the treatment given to the theme of the letter to be outlined. This article aims to identify the concepts of the reader in the correspondence exchanged by the main characters, Charlô and Felpo, core of the development of the narrative (FURNARI, 2006. These concepts allow us to comprehend, in a discursive and dialogical perspective, which boundaries remain for the reader towards the text and which are outdated.

  17. Polar plate theory for orthogonal anisotropy

    Science.gov (United States)

    Bailey, Michelle D.

    1998-11-01

    The following paper discusses the derivation and evaluation of the plate equations for a circular composite disk with orthogonal anisotropy. The work will be on a macromechanical level and include buckling, static and dynamic load applications. Necessary to a complete examination of the circular disk is the conversion of the stiffness matrix to cylindrical coordinates. In the transformed state, these coefficients are no longer constant, adding to the complexity of the proposed differential equations. Laminated fiber-reinforced (or filamentary) composites are used today for their high strength-to weight and stiffness-to-weight ratios. However, because of the typical anisotropic behavior of composites, determining the material properties on a microscopic level and the mechanics on a macroscopic level is much more difficult. This difficulty manifests itself particularly well in the evaluation of material properties and governing differential equations of a circular disk with the fibers of the lamina oriented orthogonally. One could encounter such a situation in space structures that require a circular geometry. For example, determining fastener pull through in a circular composite plate would best be performed in a polar coordinate system. In order to calculate the strain (which is a function of the angle, θ) from the displacements, the stiffness matrix and boundary conditions would need to be expressed in cylindrical coordinates. Naturally the composite would be constructed with fibers in orthogonal directions, then the necessary geometry would be cut out, thus the required lengthy transformation of coordinate systems. To bypass this derivation, numerical methods have been used and finite element models have been attempted. FEM over predicts plate stiffness by 20% and underpredicts failure by 70%. Obviously there is a need to transform classical plate theory to a cylindrical coordinate system.

  18. Digital Archive of UkrVO: first results of MAO NASU Solar System Bodies photographic plate processing

    Science.gov (United States)

    Ivanov, G.; Pakuliak, L.; Shatokhina, S.; Yizhakevych, E.; Kazantseva, L.; Andruk, V.

    The digitizing and processing of photographic plates with the images of the outer planets and their satellites from the archive collections of MAO NASU and AO of Kiev university included into the UkrVO Joint Digital Archive (JDA) have been made. Plates were obtained in the last half of the 20th century. The digitizing of JDA archive plates and inclusion of plate preview images into GPA database has been under way, using two models of flatbed scanners: Microtek ScanMaker 9800XL TMA and Epson Expression 10000XL. The database with metadata of plates is allocated on the computational resources of MAO NASU (http://gua.db.ukr-vo.org). Plates have been scanned at 16-bits grey dynamic range, with a resolution of 1200-1600 dpi, and saved in TIFF format. Linear dimensions of images are up to 13 thousand pixels (for plates 30.30 cm). The astrometric and photometric calibration procedures have been done in the LINUX-MIDASROMAFOT environment and Tycho-2 as reference with the image processing procedure specially developed for digitized images of huge linear dimensions on the basis of the image inherent traits. First results of digitized plate processing give the rms errors of 10 and 20 mas for RA, DEC respectively. (O-C) for plates with Pluto in comparison to JPL PLU021.DE405 has been derived of 140(RA) and 270(DEC) mas.

  19. Vortex-Induced Vibrations of a Flexibly-Mounted Cyber-Physical Rectangular Plate

    Science.gov (United States)

    Onoue, Kyohei; Strom, Benjamin; Song, Arnold; Breuer, Kenneth

    2013-11-01

    We have developed a cyber-physical system to explore the vortex-induced vibration (VIV) behavior of a flat plate mounted on a virtual spring damper support. The plate is allowed to oscillate about its mid-chord and the measured angular position, velocity, and torque are used as inputs to a feedback control system that provides a restoring torque and can simulate a wide range of structural dynamic behavior. A series of experiments were carried out using different sized plates, and over a range of freestream velocities, equilibrium angles of attack, and simulated stiffness and damping. We observe a synchronization phenomenon over a wide range of parameter space, wherein the plate oscillates at moderate to large amplitude with a frequency dictated by the natural structural frequency of the system. Additionally, the existence of bistable states is reflected in the hysteretic response of the system. The cyber-physical damping extracts energy from the flow and the efficiency of this harvesting mechanism is characterized over a range of dimensionless stiffness and damping parameters. This research is funded by the Air Force Office of Scientific Research (AFOSR).

  20. Optimization of Biosensors by Directed Evolution

    National Research Council Canada - National Science Library

    Fierke, Carol

    2003-01-01

    .... We used these Defense University Research Instrumentation Program funds to purchase a Perkin-Elmer GeneAmp PCR System 2400 thermal cycler and a SpectraMax Plus plate reader from Molecular Dynamics...

  1. EXPANDA-75: one-dimensional diffusion code for multi-region plate lattice heterogeneous system

    International Nuclear Information System (INIS)

    Kikuchi, Yasuyuki; Katsuragi, Satoru; Suzuki, Tomoo; Ogitsu, Makoto.

    1975-08-01

    An advanced treatment has been developed for analyzing a multi-region plate lattice heterogeneous system using the coarse group constants set provided for a homogeneous system. The essential points of this treatment are modification of effective admixture cross sections and improvement of effective elastic removal cross sections. By this treatment the heterogeneity effects for flux distributions and effective cross sections in the unit cell can be reproduced accurately in comparison with the ultra fine group treatment which consumes huge amounts of computing time. Based on the present treatment and using the JAERI-Fast set, a one-dimensional diffusion code, EXPANDA-75, was developed for extensive use for analyses of fast critical experiments. The user's guide is also presented in this report. (auth.)

  2. Social Imaginary in web advertising of e-readers

    Directory of Open Access Journals (Sweden)

    Silvina Marcela Angelozzi

    2015-04-01

    Full Text Available This paper explores the imaginary meanings that appear in the advertising discourses on e-book reading devices commonly known as e-readers. It starts from the assumption that imaginary meanings are associated with both: the imaginary associated to digital technologies (Cabrera, 2006, 2011 and to the imaginary of "order of books" (Chartier, 2000, 2005. In order to carry out the exploration, the advertising discourses in the homepages of three cases are analized: The Amazon Kindle, Kobo and MovistarBq brands. The conclusion is that e-readers are devices that participate of the imaginary of the digital technologies as other devices in the complex of digital technologies in everyday life, and also refers strongly to the imaginary meanings related to printed books.

  3. BOOK REVIEW: Astrophysics (Advanced Physics Readers)

    Science.gov (United States)

    Kibble, Bob

    2000-07-01

    Here is a handy and attractive reader to support students on post-16 courses. It covers the astrophysics, astronomy and cosmology that are demanded at A-level and offers anyone interested in these fields an interesting and engaging reference book. The author and the production team deserve credit for producing such an attractive book. The content, in ten chapters, covers what one would expect at this level but it is how it is presented that struck me as the book's most powerful asset. Each chapter ends with a summary of key ideas. Line drawings are clear and convey enough information to make them more than illustrations - they are as valuable as the text in conveying information. Full colour is used throughout to enhance illustrations and tables and to lift key sections of the text. A number of colour photographs complement the material and serve to maintain interest and remind readers that astrophysics is about real observable phenomena. Included towards the end is a set of tables offering information on physical and astronomical data, mathematical techniques and constellation names and abbreviations. This last table puzzled me as to its value. There is a helpful bibliography which includes society contacts and a website related to the text. Perhaps my one regret is that there is no section where students are encouraged to actually do some real astronomy. Astrophysics is in danger of becoming an armchair and calculator interest. There are practical projects that students could undertake either for school assessment or for personal interest. Simple astrophotography to capture star trails, observe star colours and estimate apparent magnitudes is an example, as is a simple double-star search. There are dozens more. However, the author's style is friendly and collaborative. He befriends the reader as they journey together through the ideas. There are progress questions at the end of each chapter. Their style tends to be rather closed and they emphasize factual recall

  4. A prospective randomized study of operative treatment for noncomminuted humeral shaft fractures: conventional open plating versus minimal invasive plate osteosynthesis.

    Science.gov (United States)

    Kim, Ji Wan; Oh, Chang-Wug; Byun, Young-Soo; Kim, Jung Jae; Park, Ki Chul

    2015-04-01

    To compare the clinical and radiologic results of conventional open plating (COP) and minimally invasive plate osteosynthesis (MIPO) in the treatment of noncomminuted humeral shaft fractures. Randomized prospective study. Five level 1 trauma centers. Sixty-eight consecutive patients were randomized into 2 study groups: those treated by COP (COP group; n = 32) and those treated by MIPO (MIPO group; n = 36). Simple humeral shaft fractures (AO/OTA classification types A and B) were reduced by open reduction or closed reduction and fixed with a narrow 4.5/5.0 locking compression plate, metaphyseal locking compression plate, or proximal humeral internal locking system plate to the anterior lateral aspect of the humerus. Fracture healing time, operative time, radiation exposure time, and intraoperative nerve injury. To assess shoulder and elbow function, we used the University of California, Los Angeles (UCLA) scoring system and the Mayo elbow performance index, including the range of motion and pain. Radiographic measurements included fracture alignment, delayed union, and nonunion. Thirty-one fractures (97%) healed in the COP group within 16 weeks, whereas 36 fractures (100%) were healed in the MIPO group by 15 weeks. No significant difference was observed in the operative time or complication rates. In both groups, all fractures achieved union without malunion and with excellent functional outcomes by definition of the Mayo elbow performance index and UCLA scoring system. This study confirmed a high overall rate of union and excellent functional outcomes in both MIPO and COP groups. MIPO is equivalent to COP as a safe and effective method for simple types of humeral shaft fractures when surgery is indicated, and the surgeon is experienced in the technique. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

  5. Tactile spatial resolution in blind braille readers.

    Science.gov (United States)

    Van Boven, R W; Hamilton, R H; Kauffman, T; Keenan, J P; Pascual-Leone, A

    2000-06-27

    To determine if blind people have heightened tactile spatial acuity. Recently, studies using magnetic source imaging and somatosensory evoked potentials have shown that the cortical representation of the reading fingers of blind Braille readers is expanded compared to that of fingers of sighted subjects. Furthermore, the visual cortex is activated during certain tactile tasks in blind subjects but not sighted subjects. The authors hypothesized that the expanded cortical representation of fingers used in Braille reading may reflect an enhanced fidelity in the neural transmission of spatial details of a stimulus. If so, the quantitative limit of spatial acuity would be superior in blind people. The authors employed a grating orientation discrimination task in which threshold performance is accounted for by the spatial resolution limits of the neural image evoked by a stimulus. The authors quantified the psychophysical limits of spatial acuity at the middle and index fingers of 15 blind Braille readers and 15 sighted control subjects. The mean grating orientation threshold was significantly (p = 0.03) lower in the blind group (1.04 mm) compared to the sighted group (1.46 mm). The self-reported dominant reading finger in blind subjects had a mean grating orientation threshold of 0.80 mm, which was significantly better than other fingers tested. Thresholds at non-Braille reading fingers in blind subjects averaged 1.12 mm, which were also superior to sighted subjects' performances. Superior tactile spatial acuity in blind Braille readers may represent an adaptive, behavioral correlate of cortical plasticity.

  6. Ultrasonic Low-Friction Containment Plate for Thermal and Ultrasonic Stir Weld Processes

    Science.gov (United States)

    Graff, Karl; Short, Matt

    2013-01-01

    The thermal stir welding (TSW) process is finding applications in fabrication of space vehicles. In this process, workpieces to be joined by TSW are drawn, by heavy forces, between "containment plates," past the TSW tool that then causes joining of the separate plates. It is believed that the TSW process would be significantly improved by reducing the draw force, and that this could be achieved by reducing the friction forces between the workpieces and containment plates. Based on use of high-power ultrasonics in metal forming processes, where friction reduction in drawing dies has been achieved, it is believed that ultrasonic vibrations of the containment plates could achieve similar friction reduction in the TSW process. By applying ultrasonic vibrations to the containment plates in a longitudinal vibration mode, as well as by mounting and holding the containment plates in a specific manner such as to permit the plates to acoustically float, friction between the metal parts and the containment plates is greatly reduced, and so is the drawing force. The concept was to bring in the ultrasonics from the sides of the plates, permitting the ultrasonic hardware to be placed to the side, away from the equipment that contains the thermal stir tooling and that applies clamping forces to the plates. Tests demonstrated that one of the major objectives of applying ultrasonics to the thermal stir system, that of reducing draw force friction, should be achievable on a scaled-up system.

  7. CAC on a MAC: Setting up a DOD Common Access Card Reader on the Macintosh OS X Operating System

    National Research Council Canada - National Science Library

    Hopfner, Phil

    2006-01-01

    .... The CAC readers in conjunction with the user's Smart Card enables access to DoD PKI-enabled websites and allows the user to send signed and encrypted email utilizing the DoD Public Key Infrastructure (PKI...

  8. Do good and poor readers make use of morphemic structure in English word recognition?

    Directory of Open Access Journals (Sweden)

    Lynne G. Duncan

    2011-06-01

    Full Text Available The links between oral morphological awareness and the use of derivational morphology are examined in the English word recognition of 8-year-old good and poor readers. Morphological awareness was assessed by a sentence completion task. The role of morphological structure in lexical access was examined by manipulating the presence of embedded words and suffixes in items presented for lexical decision. Good readers were more accurate in the morphological awareness task but did not show facilitation for real derivations even though morpho-semantic information appeared to inform their lexical decisions. The poor readers, who were less accurate, displayed a strong lexicality effect in lexical decision and the presence of an embedded word led to facilitation for words and inhibition for pseudo-words. Overall, the results suggest that both good and poor readers of English are sensitive to the internal structure of written words, with the better readers showing most evidence of morphological analysis.

  9. Analytical validation of an ultra low-cost mobile phone microplate reader for infectious disease testing.

    Science.gov (United States)

    Wang, Li-Ju; Naudé, Nicole; Demissie, Misganaw; Crivaro, Anne; Kamoun, Malek; Wang, Ping; Li, Lei

    2018-07-01

    Most mobile health (mHealth) diagnostic devices for laboratory tests only analyze one sample at a time, which is not suitable for large volume serology testing, especially in low-resource settings with shortage of health professionals. In this study, we developed an ultra-low-cost clinically-accurate mobile phone microplate reader (mReader), and clinically validated this optical device for 12 infectious disease tests. The mReader optically reads 96 samples on a microplate at one time. 771 de-identified patient samples were tested for 12 serology assays for bacterial/viral infections. The mReader and the clinical instrument blindly read and analyzed all tests in parallel. The analytical accuracy and the diagnostic performance of the mReader were evaluated across the clinical reportable categories by comparison with clinical laboratorial testing results. The mReader exhibited 97.59-99.90% analytical accuracy and envision the mReader can benefit underserved areas/populations and low-resource settings in rural clinics/hospitals at a low cost (~$50 USD) with clinical-level analytical quality. It has the potential to improve health access, speed up healthcare delivery, and reduce health disparities and education disparities by providing access to a low-cost spectrophotometer. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Dynamic coupled piezothermoelasticity of pyroelectric composite plate

    International Nuclear Information System (INIS)

    Heidary, F.; Reza Eslami, M.

    2005-01-01

    The equations governing the linear response of coupled piezothermolelastic composite plate, considering the pyroelectric effect, are outlined in this paper. The finite element method with linear shape functions for a first-order shear deformation theory of laminated plates is used to obtain the defections and temperature. The finite element equations are developed for piezothermoelectric sensor and actuator. The governing equations are solved using the time marching method. Numerical results are presented for the conventional active direct proportional control of the plate. Controlled and uncontrolled displacements and temperature responses are graphically illustrated. the corresponding temperature response with consideration of the pyroelectric effects is also presented. Dynamic case studies are carried out to observe the pyroelectric effects in the piezothermoelastic control systems. (authors)

  11. An investigation of coated aluminium bipolar plates for PEMFC

    International Nuclear Information System (INIS)

    Lin, Chien-Hung; Tsai, Sung-Ying

    2012-01-01

    Highlights: ► Coated aluminium bipolar plates demonstrate the hydrophobic property than the raw material. ► The corrosion behaviour of bipolar plate decreases the PEMFC performance severely. ► These PEMFCs are measured by current–voltage (I–V) curve test. ► The oxide film increases the interfacial contact resistance. -- Abstract: The performance of Al-alloy bipolar plates for the PEMFC (proton exchange membrane fuel cell) system is investigated in this paper. The metallic bipolar plates are modified with a Ni–P coating. The performance of the Al-alloy bipolar plates is evaluated by the coating structure, corrosion resistance, contact angle and single cell performance. The results indicate that the coated aluminium bipolar plates demonstrate hydrophobic and anti-corrosive properties. The hydrophobic property increases the contact angle on the surface from 46.08° to 80.51°. Meanwhile, the corrosion rate of the Ni–P coating can be over 1 order of magnitude lower than that of the substrate. Hence, the substrate with the coating maintains superior performance under the long term test. The present study proves that both the hydrophobicity and corrosion resistance significantly affect the metallic bipolar plate.

  12. Developing Historical Reading and Writing with Adolescent Readers: Effects on Student Learning

    Science.gov (United States)

    De La Paz, Susan; Felton, Mark; Monte-Sano, Chauncey; Croninger, Robert; Jackson, Cara; Deogracias, Jeehye Shim; Hoffman, Benjamin Polk

    2014-01-01

    In this study, the effects of a disciplinary reading and writing curriculum intervention with professional development are shared. We share our instructional approach and provide writing outcomes for struggling adolescent readers who read at or below basic proficiency levels, as well as writing outcomes for proficient and advanced readers.…

  13. Literature Discussion: Encouraging Reading Interest and Comprehension in Struggling Middle School Readers

    Science.gov (United States)

    Pittman, Pamela; Honchell, Barbara

    2014-01-01

    The purpose of this qualitative study was to explore how literature discussion affects middle school struggling readers. The focus was on 16 middle school struggling readers in a rural Title I school in the southeastern United States. Findings indicated that (a) literature discussion increased student enjoyment of reading, and (b) students…

  14. Bifurcation of cubic nonlinear parallel plate-type structure in axial flow

    International Nuclear Information System (INIS)

    Lu Li; Yang Yiren

    2005-01-01

    The Hopf bifurcation of plate-type beams with cubic nonlinear stiffness in axial flow was studied. By assuming that all the plates have the same deflections at any instant, the nonlinear model of plate-type beam in axial flow was established. The partial differential equation was turned into an ordinary differential equation by using Galerkin method. A new algebraic criterion of Hopf bifurcation was utilized to in our analysis. The results show that there's no Hopf bifurcation for simply supported plate-type beams while the cantilevered plate-type beams has. At last, the analytic expression of critical flow velocity of cantilevered plate-type beams in axial flow and the purely imaginary eigenvalues of the corresponding linear system were gotten. (authors)

  15. Low cost bare-plate solar air collector

    Science.gov (United States)

    Maag, W. L.; Wenzler, C. J.; Rom, F. E.; Vanarsdale, D. R.

    1980-09-01

    A low cost, bare plate solar collector for preheating ambient air was developed. This type of solar heating system would be applicable for preheating ventilation air for public buildings or other commercial and industrial ventilation requirements. Two prototype collectors were designed, fabricated and installed into an instrumented test system. Tests were conducted for a period of five months. Results of the tests showed consistent operating efficiencies of 60 percent or greater with air preheat temperature uses up to 20 degrees for one of the prototypes. The economic analyses indicated that this type of solar system was economically viable. For the materials of construction and the type of fabrication and installation perceived, costs for the bare plate solar collector are attainable. Applications for preheating ventilation air for schools were evaluated and judged to be economically viable.

  16. Comparative evaluation of image quality in computed radiology systems using imaging plates with different usage time

    International Nuclear Information System (INIS)

    Lazzaro, M.V.; Luz, R.M. da; Capaverde, A.S.; Silva, A.M. Marques da

    2015-01-01

    Computed Radiology (CR) systems use imaging plates (IPs) for latent image acquisition. Taking into account the quality control (QC) of these systems, imaging plates usage time is undetermined. Different recommendations and publications on the subject suggest tests to evaluate these systems. The objective of this study is to compare the image quality of IPs of a CR system, in a mammography service, considering the usage time and consistency of assessments. 8 IPs were used divided into two groups: the first group included 4 IPs with 3 years of use (Group A); the second group consisted of 4 new IPs with no previous exposure (Group B). The tests used to assess the IP's quality were: Uniformity, Differential Signal to Noise Ratio (SDNR), Ghost Effect and Figure of Merit (FOM). Statistical results show that the proposed tests are shown efficient in assessing the conditions of image quality obtained in CR systems in mammography and can be used as determining factors for the replacement of IP's. Moreover, comparing the two sets of IP, results led to the replacement of all the set of IP’s with 3 years of use. This work demonstrates the importance of an efficient quality control, not only with regard to the quality of IP's used, but in the acquisition system as a whole. From this work, these tests will be conducted on an annual basis, already targeting as future work, monitoring the wear of IP's Group B and the creation of a baseline for analysis and future replacements. (author)

  17. A new license plate extraction framework based on fast mean shift

    Science.gov (United States)

    Pan, Luning; Li, Shuguang

    2010-08-01

    License plate extraction is considered to be the most crucial step of Automatic license plate recognition (ALPR) system. In this paper, a region-based license plate hybrid detection method is proposed to solve practical problems under complex background in which existing large quantity of disturbing information. In this method, coarse license plate location is carried out firstly to get the head part of a vehicle. Then a new Fast Mean Shift method based on random sampling of Kernel Density Estimate (KDE) is adopted to segment the color vehicle images, in order to get candidate license plate regions. The remarkable speed-up it brings makes Mean Shift segmentation more suitable for this application. Feature extraction and classification is used to accurately separate license plate from other candidate regions. At last, tilted license plate regulation is used for future recognition steps.

  18. Patterns of Analogical Reasoning among Beginning Readers

    Science.gov (United States)

    Farrington-Flint, Lee; Wood, Clare; Canobi, Katherine H.; Faulkner, Dorothy

    2004-01-01

    Despite compelling evidence that analogy skills are available to beginning readers, few studies have actually explored the possibility of identifying individual differences in young children's analogy skills in early reading. The present study examined individual differences in children's use of orthographic and phonological relations between…

  19. Evaluating the effect of a reader worker program on team performance

    International Nuclear Information System (INIS)

    Hahn, H.A.; Alvarez, Y.P.

    1994-01-01

    When safety, security, or other logistical concerns prevent direct objective assessment of team performance, other evaluation techniques become necessary. In this paper, the effect of a Department of Energy-mandated reader worker program on team performance at a particular DOE facility was evaluated using unstructured observations, informal discussions with technicians, and human reliability analysis. The reader worker program is intended to enhance nuclear explosive safety by improving the reliability of team performance. The three methods used for the evaluation combine to provide a strong indication that team performance is in fact enhanced by a properly implemented reader worker procedure. Because direct quantitative data on dependent variables particular to the task of interest is not available, however, there has been some skepticism regarding the results by staff at the facility

  20. Tracking the India-Arabia Transform Plate Boundary during Paleogene Times.

    Science.gov (United States)

    Rodriguez, M.; Huchon, P.; Chamot-Rooke, N. R. A.; Fournier, M.; Delescluse, M.

    2014-12-01

    The Zagros and Himalaya mountain belts are the most prominent reliefs built by continental collision. They respectively result from Arabia and India collision with Eurasia. Convergence motions at mountain belts induced most of plate reorganization events in the Indian Ocean during the Cenozoic. Although critical for paleogeographic reconstructions, the way relative motion between Arabia and India was accommodated prior to the formation of the Sheba ridge in the Gulf of Aden remains poorly understood. The India-Arabia plate-boundary belongs to the category of long-lived (~90-Ma) oceanic transform faults, thus providing a good case study to investigate the role of major kinematic events over the structural evolution of a long-lived transform system. A seismic dataset crossing the Owen Fracture Zone, the Owen Basin, and the Oman Margin was acquired to track the past locations of the India-Arabia plate boundary. We highlight the composite age of the Owen Basin basement, made of Paleocene oceanic crust drilled on its eastern part, and composed of pre-Maastrichtian continental crust overlaid by Early Paleocene ophiolites on its western side. A major transform fault system crossing the Owen Basin juxtaposed these two slivers of lithosphere of different ages, and controlled the uplift of marginal ridges along the Oman Margin. This transform system deactivated ~40 Ma ago, coeval with the onset of ultra-slow spreading at the Carlsberg Ridge. The transform boundary then jumped to the edge of the present-day Owen Ridge during the Late Eocene-Oligocene period, before seafloor spreading began at the Sheba Ridge. This migration of the plate boundary involved the transfer of a part of the Indian oceanic lithosphere accreted at the Carlsberg Ridge to the Arabian plate. The episode of plate transfer at the India-Arabia plate boundary during the Late Eocene-Oligocene interval is synchronous with a global plate reorganization event corresponding to geological events at the Zagros and

  1. Imaging features of ductal plate malformations in adults

    Energy Technology Data Exchange (ETDEWEB)

    Venkatanarasimha, N., E-mail: nandashettykv@yahoo.com [Department of Radiology, Derriford Hospital, Plymouth (United Kingdom); Thomas, R.; Armstrong, E.M.; Shirley, J.F.; Fox, B.M.; Jackson, S.A. [Department of Radiology, Derriford Hospital, Plymouth (United Kingdom)

    2011-11-15

    Ductal plate malformations, also known as fibrocystic liver diseases, are a group of congenital disorders resulting from abnormal embryogenesis of the biliary ductal system. The abnormalities include choledochal cyst, Caroli's disease and Caroli's syndrome, adult autosomal dominant polycystic liver disease, and biliary hamartoma. The hepatic lesions can be associated with renal anomalies such as autosomal recessive polycystic kidney disease (ARPKD), medullary sponge kidney, and nephronophthisis. A clear knowledge of the embryology and pathogenesis of the ductal plate is central to the understanding of the characteristic imaging appearances of these complex disorders. Accurate diagnosis of ductal plate malformations is important to direct appropriate clinical management and prevent misdiagnosis.

  2. Contributions of syntactic awareness to reading in Chinese-speaking adolescent readers with and without dyslexia.

    Science.gov (United States)

    Chung, Kevin K H; Ho, Connie S-H; Chan, David W; Tsang, Suk-Man; Lee, Suk-Han

    2013-02-01

    This study investigated the relative contribution of syntactic awareness to Chinese reading among Chinese-speaking adolescent readers with and without dyslexia. A total of 78 junior high school students in Hong Kong, 26 dyslexic adolescent readers, 26 average adolescent readers of the same age (chronological age control group) and 26 younger readers matched with the same reading level (reading-level group) participated and were administered measures of IQ, syntactic awareness, morphological awareness, vocabulary knowledge, working memory, word reading, and reading comprehension. Results showed that dyslexic readers scored significantly lower than chronological age but similarly to reading level control groups in most measures, especially in the areas of syntactic skills. Analyses of individual data also revealed that over half of the dyslexic readers exhibited certain aspects of deficits in syntactic skills. In regression analyses, syntactic skills were the strongest predictors of ability in word reading and reading comprehension measures. This study highlights the uniquely important correlates of syntactic skills in Chinese reading acquisition and impairment. Copyright © 2013 John Wiley & Sons, Ltd.

  3. Subduction Drive of Plate Tectonics

    Science.gov (United States)

    Hamilton, W. B.

    2003-12-01

    Don Anderson emphasizes that plate tectonics is self-organizing and is driven by subduction, which rights the density inversion generated as oceanic lithosphere forms by cooling of asthenosphere from the top. The following synthesis owes much to many discussions with him. Hinge rollback is the key to kinematics, and, like the rest of actual plate behavior, is incompatible with bottom-up convection drive. Subduction hinges (which are under, not in front of, thin leading parts of arcs and overriding plates) roll back into subducting plates. The Pacific shrinks because bounding hinges roll back into it. Colliding arcs, increasing arc curvatures, back-arc spreading, and advance of small arcs into large plates also require rollback. Forearcs of overriding plates commonly bear basins which preclude shortening of thin plate fronts throughout periods recorded by basin strata (100 Ma for Cretaceous and Paleogene California). This requires subequal rates of advance and rollback, and control of both by subduction. Convergence rate is equal to rates of rollback and advance in many systems but is greater in others. Plate-related circulation probably is closed above 650 km. Despite the popularity of concepts of plumes from, and subduction into, lower mantle, there is no convincing evidence for, and much evidence against, penetration of the 650 in either direction. That barrier not only has a crossing-inhibiting negative Clapeyron slope but also is a compositional boundary between fractionated (not "primitive"), sluggish lower mantle and fertile, mobile upper mantle. Slabs sink more steeply than they dip. Slabs older than about 60 Ma when their subduction began sink to, and lie down on and depress, the 650-km discontinuity, and are overpassed, whereas younger slabs become neutrally buoyant in mid-upper mantle, into which they are mixed as they too are overpassed. Broadside-sinking old slabs push all upper mantle, from base of oceanic lithosphere down to the 650, back under

  4. Simulating faults and plate boundaries with a transversely isotropic plasticity model

    Science.gov (United States)

    Sharples, W.; Moresi, L. N.; Velic, M.; Jadamec, M. A.; May, D. A.

    2016-03-01

    In mantle convection simulations, dynamically evolving plate boundaries have, for the most part, been represented using an visco-plastic flow law. These systems develop fine-scale, localized, weak shear band structures which are reminiscent of faults but it is a significant challenge to resolve the large- and the emergent, small-scale-behavior. We address this issue of resolution by taking into account the observation that a rock element with embedded, planar, failure surfaces responds as a non-linear, transversely isotropic material with a weak orientation defined by the plane of the failure surface. This approach partly accounts for the large-scale behavior of fine-scale systems of shear bands which we are not in a position to resolve explicitly. We evaluate the capacity of this continuum approach to model plate boundaries, specifically in the context of subduction models where the plate boundary interface has often been represented as a planar discontinuity. We show that the inclusion of the transversely isotropic plasticity model for the plate boundary promotes asymmetric subduction from initiation. A realistic evolution of the plate boundary interface and associated stresses is crucial to understanding inter-plate coupling, convergent margin driven topography, and earthquakes.

  5. Acquisition of Malay Word Recognition Skills: Lessons from Low-Progress Early Readers

    Science.gov (United States)

    Lee, Lay Wah; Wheldall, Kevin

    2011-01-01

    Malay is a consistent alphabetic orthography with complex syllable structures. The focus of this research was to investigate word recognition performance in order to inform reading interventions for low-progress early readers. Forty-six Grade 1 students were sampled and 11 were identified as low-progress readers. The results indicated that both…

  6. Detection of License Plate using Sliding Window, Histogram of Oriented Gradient, and Support Vector Machines Method

    Science.gov (United States)

    Astawa, INGA; Gusti Ngurah Bagus Caturbawa, I.; Made Sajayasa, I.; Dwi Suta Atmaja, I. Made Ari

    2018-01-01

    The license plate recognition usually used as part of system such as parking system. License plate detection considered as the most important step in the license plate recognition system. We propose methods that can be used to detect the vehicle plate on mobile phone. In this paper, we used Sliding Window, Histogram of Oriented Gradient (HOG), and Support Vector Machines (SVM) method to license plate detection so it will increase the detection level even though the image is not in a good quality. The image proceed by Sliding Window method in order to find plate position. Feature extraction in every window movement had been done by HOG and SVM method. Good result had shown in this research, which is 96% of accuracy.

  7. The San Andreas fault experiment. [gross tectonic plates relative velocity

    Science.gov (United States)

    Smith, D. E.; Vonbun, F. O.

    1973-01-01

    A plan was developed during 1971 to determine gross tectonic plate motions along the San Andreas Fault System in California. Knowledge of the gross motion along the total fault system is an essential component in the construction of realistic deformation models of fault regions. Such mathematical models will be used in the future for studies which will eventually lead to prediction of major earthquakes. The main purpose of the experiment described is the determination of the relative velocity of the North American and the Pacific Plates. This motion being so extremely small, cannot be measured directly but can be deduced from distance measurements between points on opposite sites of the plate boundary taken over a number of years.

  8. Design and construction of the liner plate for the Arkansas and Midland containments

    International Nuclear Information System (INIS)

    Wiedner, K.; Shah, G.H.; Chang-Lo, P.

    1976-01-01

    This paper presents the design criteria and features of the containment liner plate systems utilized for the Arkansas and Midland Nuclear Power Plant. For the Arkansas project, the liner plate system was erected in circumferential rings approximately 3 m high, and the penetration assemblies were welded into the liner after erection. For the Midland project, the liner plate system was erected in vertical segments approximately 6 m wide x 24 m high, and the penetration assemblies were welded into the liner prior to erection. The differences between the schemes are discussed. (author)

  9. A Plate Tectonic Model for the Neoproterozoic with Evolving Plate Boundaries

    Science.gov (United States)

    Merdith, Andrew; Collins, Alan; Williams, Simon; Pisarevsky, Sergei; Müller, Dietmar

    2017-04-01

    margin sediments along its southern margin during the Tonian. The model depicts a sequential breakup of Rodinia, with Australia-Antarctica rifting first ( 800 Ma), Congo-São Francisco (and the Sahara Metacraton) second ( 750 Ma) and Kalahari third (700 Ma). Amazonia and West Africa rift later with the opening of the Iapetus Ocean from 600 Ma. We expect that this global model will assist in the development of future regional models for the Neoproterozoic, and that the production of this full-plate topological reconstruction will facilitate the investigation of controls on other earth systems, such as the possible role of volcanism on initiation of the Cryogenian, or the nature of mantle convection in the Neoproterozoic.

  10. Mathematical methods for elastic plates

    CERN Document Server

    Constanda, Christian

    2014-01-01

    Mathematical models of deformation of elastic plates are used by applied mathematicians and engineers in connection with a wide range of practical applications, from microchip production to the construction of skyscrapers and aircraft. This book employs two important analytic techniques to solve the fundamental boundary value problems for the theory of plates with transverse shear deformation, which offers a more complete picture of the physical process of bending than Kirchhoff’s classical one.   The first method transfers the ellipticity of the governing system to the boundary, leading to singular integral equations on the contour of the domain. These equations, established on the basis of the properties of suitable layer potentials, are then solved in spaces of smooth (Hölder continuous and Hölder continuously differentiable) functions.   The second technique rewrites the differential system in terms of complex variables and fully integrates it, expressing the solution as a combination of complex ana...

  11. History of internal fixation with plates (part 2): new developments after World War II; compressing plates and locked plates.

    Science.gov (United States)

    Hernigou, Philippe; Pariat, Jacques

    2017-07-01

    The first techniques of operative fracture with plates were developed in the 19th century. In fact, at the beginning these methods consisted of an open reduction of the fracture usually followed by a very unstable fixation. As a consequence, the fracture had to be opened with a real risk of (sometimes lethal) infection, and due to unstable fixation, protection with a cast was often necessary. During the period between World Wars I and II, plates for fracture fixation developed with great variety. It became increasingly recognised that, because a fracture of a long bone normally heals with minimal resorption at the bone ends, this may result in slight shortening and collapse, so a very rigid plate might prevent such collapse. However, as a consequence, delayed healing was observed unless the patient was lucky enough to have the plate break. One way of dealing with this was to use a slotted plate in which the screws could move axially, but the really important advance was recognition of the role of compression. After the first description of compression by Danis with a "coapteur", Bagby and Müller with the AO improved the technique of compression. The classic dynamic compression plates from the 1970s were the key to a very rigid fixation, leading to primary bone healing. Nevertheless, the use of strong plates resulted in delayed union and the osteoporosis, cancellous bone, comminution, and/or pathological bone resulted in some failures due to insufficient stability. Finally, new devices represented by locking plates increased the stability, contributing to the principles of a more biological osteosynthesis while giving enough stability to allow immediate full weight bearing in some patients.

  12. Scanometry as microplate reader for high throughput method based on DPPH dry reagent for antioxidant assay

    Directory of Open Access Journals (Sweden)

    Mochammad Amrun Hidayat

    2017-05-01

    Full Text Available The stable chromogenic radical 1,1′-diphenyl-2-picrylhydrazyl (DPPH solution was immobilized on the microwell plate as dry reagent to construct a simple antioxidant sensor. Then, a regular flatbed scanner was used as microplate reader to obtain analytical parameters for antioxidant assay using one-shot optical sensors as scanometry technique. Variables affecting the acquisition of the images were optimized and the analytical parameters are obtained from an area of the sensing zone inside microwell using the average luminosity of the sensing zone captured as the mean of red, green, and blue (RGB value using ImageJ® program. By using this RGB value as sensor response, it is possible to determine antioxidant capacity in the range 1–25 ppm as gallic acid equivalent (GAE with the response time of 9 min. The reproducibility of sensor was good (RSD<1% with recovery at 93%–96%. The antioxidant sensor was applied to the plant extracts, such as sappan wood and Turmeric Rhizome. The results are good when compared to the same procedure using a UV/Vis spectrophotometer.

  13. Mathematics skills in good readers with hydrocephalus.

    Science.gov (United States)

    Barnes, Marcia A; Pengelly, Sarah; Dennis, Maureen; Wilkinson, Margaret; Rogers, Tracey; Faulkner, Heather

    2002-01-01

    Children with hydrocephalus have poor math skills. We investigated the nature of their arithmetic computation errors by comparing written subtraction errors in good readers with hydrocephalus, typically developing good readers of the same age, and younger children matched for math level to the children with hydrocephalus. Children with hydrocephalus made more procedural errors (although not more fact retrieval or visual-spatial errors) than age-matched controls; they made the same number of procedural errors as younger, math-level matched children. We also investigated a broad range of math abilities, and found that children with hydrocephalus performed more poorly than age-matched controls on tests of geometry and applied math skills such as estimation and problem solving. Computation deficits in children with hydrocephalus reflect delayed development of procedural knowledge. Problems in specific math domains such as geometry and applied math, were associated with deficits in constituent cognitive skills such as visual spatial competence, memory, and general knowledge.

  14. Pc-based car license plate reading

    Science.gov (United States)

    Tanabe, Katsuyoshi; Marubayashi, Eisaku; Kawashima, Harumi; Nakanishi, Tadashi; Shio, Akio

    1994-03-01

    A PC-based car license plate recognition system has been developed. The system recognizes Chinese characters and Japanese phonetic hiragana characters as well as six digits on Japanese license plates. The system consists of a CCD camera, vehicle sensors, a strobe unit, a monitoring center, and an i486-based PC. The PC includes in its extension slots: a vehicle detector board, a strobe emitter board, and an image grabber board. When a passing vehicle is detected by the vehicle sensors, the strobe emits a pulse of light. The light pulse is synchronized with the time the vehicle image is frozen on an image grabber board. The recognition process is composed of three steps: image thresholding, character region extraction, and matching-based character recognition. The recognition software can handle obscured characters. Experimental results for hundreds of outdoor images showed high recognition performance within relatively short performance times. The results confirmed that the system is applicable to a wide variety of applications such as automatic vehicle identification and travel time measurement.

  15. Progressive phase trends in plates with embedded acoustic black holes.

    Science.gov (United States)

    Conlon, Stephen C; Feurtado, Philip A

    2018-02-01

    Acoustic black holes (ABHs) have been explored and demonstrated to be effective passive treatments for broadband noise and vibration control. Performance metrics for assessing damping concepts are often focused on maximizing structural damping loss factors. Optimally performing damping treatments can reduce the resonant response of a driven system well below the direct field response. This results in a finite structure whose vibration input-output response follows that of an infinite structure. The vibration mobility transfer functions between locations on a structure can be used to assess the structure's vibration response phase, and compare its phase response characteristics to those of idealized systems. This work experimentally explores the phase accumulation in finite plates, with and without embedded grids of ABHs. The measured results are compared and contrasted with theoretical results for finite and infinite uniform plates. Accumulated phase characteristics, their spatial dependence and limits, are examined for the plates and compared to theoretical estimates. The phase accumulation results show that the embedded acoustic black hole treatments can significantly enhance the damping of the plates to the point that their phase accumulation follows that of an infinite plate.

  16. Vibro-acoustic modeling and analysis of a coupled acoustic system comprising a partially opened cavity coupled with a flexible plate

    Science.gov (United States)

    Shi, Shuangxia; Su, Zhu; Jin, Guoyong; Liu, Zhigang

    2018-01-01

    This paper is concerned with the modeling and solution method of a three-dimensional (3D) coupled acoustic system comprising a partially opened cavity coupled with a flexible plate and an exterior field of semi-infinite size, which is ubiquitously encountered in architectural acoustics and is a reasonable representation of many engineering occasions. A general solution method is presented to predict the dynamic behaviors of the three-dimensional (3D) acoustic coupled system, in which the displacement of the plate and the sound pressure in the cavity are respectively constructed in the form of the two-dimensional and three-dimensional modified Fourier series with several auxiliary functions introduced to ensure the uniform convergence of the solution over the entire solution domain. The effect of the opening is taken into account via the work done by the sound pressure acting at the coupling aperture that is contributed from the vibration of particles on the acoustic coupling interface and on the structural-acoustic coupling interface. Both the acoustic coupling between finite cavity and exterior field and the structural-acoustic coupling between flexible plate and interior acoustic field are considered in the vibro-acoustic modeling of the three-dimensional acoustic coupled acoustic system. The dynamic responses of the coupled structural-acoustic system are obtained using the Rayleigh-Ritz procedure based on the energy expressions for the coupled system. The accuracy and effectiveness of the proposed method are validated through numerical examples and comparison with results obtained by the boundary element analysis. Furthermore, the influence of the opening and the cavity volume on the acoustic behaviors of opened cavity system is studied.

  17. Image quality and radiation exposure in digital storage plate mammography with magnification technique

    International Nuclear Information System (INIS)

    Fiedler, E.; Aichinger, U.; Boehner, C.; Schulz-Wendtland, R.; Bautz, W.; Saebel, M.

    1999-01-01

    Purpose: Comparison of image quality between digital phosphor storage plate mammography in magnification technique and a conventional film screen system regarding the special aspect of radiation exposure. Materials and Methods: Radiograms of a RMI-mammography phantom were acquired using a conventional film screen system and two digital storage plate systems. Additionally, the radiograms of one digital system were postprocessed emphasizing contrast and included in the comparison. Results: The detectability of details in storage plate mammographies with magnification technique is almost equal to that of film screen mammographies. Thereby, lower radiation exposures were necessary using the digital systems. Conclusions: Based on these results, storage plate mammography in magnification technique is used in clinical routine at our institution. The correct parameters in image postprocessing are of elementary importance for detail detectability. Future studies must show, whether the lower radiation exposure in digital radiograms of the breast, revealing much higher background noise, will allow the same detail detectability as film screen mammographies. (orig.) [de

  18. Cross-calibration of Fuji TR image plate and RAR 2492 x-ray film to determine the response of a DITABIS Super Micron image plate scanner

    Energy Technology Data Exchange (ETDEWEB)

    Dunham, G., E-mail: gsdunha@sandia.gov; Harding, E. C.; Loisel, G. P.; Lake, P. W.; Nielsen-Weber, L. B. [Sandia National Laboratories, Albuquerque, New Mexico 87185 (United States)

    2016-11-15

    Fuji TR image plate is frequently used as a replacement detector medium for x-ray imaging and spectroscopy diagnostics at NIF, Omega, and Z facilities. However, the familiar Fuji BAS line of image plate scanners is no longer supported by the industry, and so a replacement scanning system is needed. While the General Electric Typhoon line of scanners could replace the Fuji systems, the shift away from photo stimulated luminescence units to 16-bit grayscale Tag Image File Format (TIFF) leaves a discontinuity when comparing data collected from both systems. For the purposes of quantitative spectroscopy, a known unit of intensity applied to the grayscale values of the TIFF is needed. The DITABIS Super Micron image plate scanning system was tested and shown to potentially rival the resolution and dynamic range of Kodak RAR 2492 x-ray film. However, the absolute sensitivity of the scanner is unknown. In this work, a methodology to cross calibrate Fuji TR image plate and the absolutely calibrated Kodak RAR 2492 x-ray film is presented. Details of the experimental configurations used are included. An energy dependent scale factor to convert Fuji TR IP scanned on a DITABIS Super Micron scanner from 16-bit grayscale TIFF to intensity units (i.e., photons per square micron) is discussed.

  19. Vibration analysis of partially cracked plate submerged in fluid

    Science.gov (United States)

    Soni, Shashank; Jain, N. K.; Joshi, P. V.

    2018-01-01

    The present work proposes an analytical model for vibration analysis of partially cracked rectangular plates coupled with fluid medium. The governing equation of motion for the isotropic plate based on the classical plate theory is modified to accommodate a part through continuous line crack according to simplified line spring model. The influence of surrounding fluid medium is incorporated in the governing equation in the form of inertia effects based on velocity potential function and Bernoulli's equations. Both partially and totally submerged plate configurations are considered. The governing equation also considers the in-plane stretching due to lateral deflection in the form of in-plane forces which introduces geometric non-linearity into the system. The fundamental frequencies are evaluated by expressing the lateral deflection in terms of modal functions. The assessment of the present results is carried out for intact submerged plate as to the best of the author's knowledge the literature lacks in analytical results for submerged cracked plates. New results for fundamental frequencies are presented as affected by crack length, fluid level, fluid density and immersed depth of plate. By employing the method of multiple scales, the frequency response and peak amplitude of the cracked structure is analyzed. The non-linear frequency response curves show the phenomenon of bending hardening or softening and the effect of fluid dynamic pressure on the response of the cracked plate.

  20. Thermal performance of plate-type loop thermosyphon at sub-atmospheric pressures

    International Nuclear Information System (INIS)

    Tsoi, Vadim; Chang, Shyy Woei; Chiang Kuei Feng; Huang, Chuan Chin

    2011-01-01

    This experimental study examines the thermal performance of a newly devised plate-type two-phase loop thermosyphon with cooling applications to electronic boards of telecommunication systems. The evaporation section is configured as the inter-connected multi channels to emulate the bridging boiling mechanism in pulsating thermosyphon. Two thermosyphon plates using water as the coolant with filling ratios (FR) of 0.22 and 0.32 are tested at sub-atmospheric pressures. The vapor-liquid flow images as well as the thermal resistances and effective spreading thermal conductivities are individually measured for each thermosyphon test plate at various heating powers. The high-speed digital images of the vapor-liquid flow structures reveal the characteristic boiling phenomena and the vapor-liquid circulation in the vertical thermosyphon plate, which assist to explore the thermal physics for this type of loop thermosyphon. The bubble agglomeration and pumping action in the inter-connected boiling channels take place at metastable non-equilibrium conditions, leading to the intermittent slug flows with a pulsation character. Such hybrid loop-pulsating thermosyphon permits the vapor-liquid circulation in the horizontal plate. Thermal resistances and spreading thermal conductivities detected from the present thermosyphon plates; the vapor chamber flat plate heat pipe and the copper plate at free and forced convective cooling conditions with both vertical and horizontal orientations are cross-examined. In most telecommunication systems and units, the electrical boards are vertical so that the thermal performance data on the vertical thermosyphon are most relevant to this particular application. - Highlights: → We examine thermal performances of plate-type loop thermosyphon. → Thermal resistances and spreading conductivities are examined. → Bubble agglomeration in inter-connected boiling channels generates intermittent slug flows with pulsations. → Boiling instability