WorldWideScience

Sample records for plate subnanosecond differences

  1. Experimental techniques for subnanosecond resolution of laser-launched plates and impact studies

    Energy Technology Data Exchange (ETDEWEB)

    Paisley, D.L.; Warnes, R.H.; Stahl, D.B. [Los Alamos National Lab., NM (United States). Dynamic Experimentation Div.

    1994-09-01

    Miniature laser-launched plates have applications in shock wave physics, studying dynamic properties of materials and can be used to generate experimental data in a manner similar to a laboratory gas gun for one-dimensional impact experiments. Laser-launched plates have the advantage of small size, low kinetic energy, and can be launched with ubiquitous laboratory lasers. Because of the small size and high accelerations (10{sup 7}--10{sup 10} g`s), improved temporal resolution and optical non-contact methods to collect data are required. Traditional mechanical in-situ gauges would significantly impair the data quality and do not have the required time response.

  2. Modeling the Conductivity of a Subnanosecond Breakdown Gas Switch

    Science.gov (United States)

    Chen, Jinhui; Scott Tyo, J.; Jerald Buchenauer, C.

    We present two different modeling methods for understanding subnanosecond breakdown processes in gas plasma switches. The first method uses a finite element time domain method in order to understand experimental measurements of the remote electromagnetic (EM) fields. This method only models the EM fields and is good for analysis, but lacks a predictive capability for the full nonlinear plasma system. The second modeling method uses a PIC code, and is fully self consistent. We make comparisons with experimental measurements and conclude that the PIC model may provide a good understanding of the subnanosecond breakdown phenomena.

  3. Neurostimulation using subnanosecond electric pulses

    Science.gov (United States)

    Xiao, Shu; Pakhomov, Andrei; Guo, Fei; Polisetty, Swetha; Schoenbach, Karl H.

    2013-02-01

    We have for the first time recorded action potentials in rat hippocampus neurons when they were stimulated by subnanosecond electric pulses. The preliminary results show that applying a series of pulses allowed the accumulation of depolarization before activating the voltage gated channels. The depolarization only occurred when the electric pulses were applied. It is unclear whether the depolarization is caused by the charge accumulation across the membrane or the cation influx due to the membrane permeabilization. We have also conducted an electromagnetic simulation of delivering subnanosecond pulses to tissues using an impulse radiating antenna. The results show that the pulses can be confined in the deep region in the brain but the amplitude is reduced significantly due to the attenuation of the tissues. A partially lossy dielectric lens may be used to reverse the decreasing trend of the electric field.

  4. Low charge state heavy ion production with sub-nanosecond laser

    Energy Technology Data Exchange (ETDEWEB)

    Kanesue, T., E-mail: tkanesue@bnl.gov; Okamura, M. [Collider-Accelerator Department, Brookhaven National Laboratory, Upton, New York 11973 (United States); Kumaki, M. [Research Institute for Science and Engineering, Waseda University, Tokyo 169-8555 (Japan); Nishina Center for Accelerator-Based Science, RIKEN, Saitama 351-0198 (Japan); Ikeda, S. [Nishina Center for Accelerator-Based Science, RIKEN, Saitama 351-0198 (Japan); Interdisciplinary Graduate School of Science and Engineering, Tokyo Institute of Technology, Kanagawa 226-8503 (Japan)

    2016-02-15

    We have investigated laser ablation plasma of various species using nanosecond and sub-nanosecond lasers for both high and low charge state ion productions. We found that with sub-nanosecond laser, the generated plasma has a long tail which has low charge state ions determined by an electrostatic ion analyzer even under the laser irradiation condition for highly charged ion production. This can be caused by insufficient laser absorption in plasma plume. This property might be suitable for low charge state ion production. We used a nanosecond laser and a sub-nanosecond laser for low charge state ion production to investigate the difference of generated plasma using the Zirconium target.

  5. Low charge state heavy ion production with sub-nanosecond laser.

    Science.gov (United States)

    Kanesue, T; Kumaki, M; Ikeda, S; Okamura, M

    2016-02-01

    We have investigated laser ablation plasma of various species using nanosecond and sub-nanosecond lasers for both high and low charge state ion productions. We found that with sub-nanosecond laser, the generated plasma has a long tail which has low charge state ions determined by an electrostatic ion analyzer even under the laser irradiation condition for highly charged ion production. This can be caused by insufficient laser absorption in plasma plume. This property might be suitable for low charge state ion production. We used a nanosecond laser and a sub-nanosecond laser for low charge state ion production to investigate the difference of generated plasma using the Zirconium target.

  6. Reliability assessment of different plate theories for elastic wave propagation analysis in functionally graded plates.

    Science.gov (United States)

    Mehrkash, Milad; Azhari, Mojtaba; Mirdamadi, Hamid Reza

    2014-01-01

    The importance of elastic wave propagation problem in plates arises from the application of ultrasonic elastic waves in non-destructive evaluation of plate-like structures. However, precise study and analysis of acoustic guided waves especially in non-homogeneous waveguides such as functionally graded plates are so complicated that exact elastodynamic methods are rarely employed in practical applications. Thus, the simple approximate plate theories have attracted much interest for the calculation of wave fields in FGM plates. Therefore, in the current research, the classical plate theory (CPT), first-order shear deformation theory (FSDT) and third-order shear deformation theory (TSDT) are used to obtain the transient responses of flexural waves in FGM plates subjected to transverse impulsive loadings. Moreover, comparing the results with those based on a well recognized hybrid numerical method (HNM), we examine the accuracy of the plate theories for several plates of various thicknesses under excitations of different frequencies. The material properties of the plate are assumed to vary across the plate thickness according to a simple power-law distribution in terms of volume fractions of constituents. In all analyses, spatial Fourier transform together with modal analysis are applied to compute displacement responses of the plates. A comparison of the results demonstrates the reliability ranges of the approximate plate theories for elastic wave propagation analysis in FGM plates. Furthermore, based on various examples, it is shown that whenever the plate theories are used within the appropriate ranges of plate thickness and frequency content, solution process in wave number-time domain based on modal analysis approach is not only sufficient but also efficient for finding the transient waveforms in FGM plates.

  7. The gastrocoel roof plate in embryos of different frogs.

    Science.gov (United States)

    Sáenz-Ponce, Natalia; Santillana-Ortiz, Juan-Diego; del Pino, Eugenia M

    2012-02-01

    The morphology of the gastrocoel roof plate and the presence of cilia in this structure were examined in embryos of four species of frogs. Embryos of Ceratophrys stolzmanni (Ceratophryidae) and Engystomops randi (Leiuperidae) develop rapidly, provide comparison for the analysis of gastrocoel roof plate development in the slow-developing embryos of Epipedobates machalilla (Dendrobatidae) and Gastrotheca riobambae (Hemiphractidae). Embryos of the analyzed frogs develop from eggs of different sizes, and display different reproductive and developmental strategies. In particular, dorsal convergence and extension and archenteron elongation begin during gastrulation in embryos of rapidly developing frogs, as in Xenopus laevis. In contrast, cells that involute during gastrulation are stored in the large circumblastoporal collar that develops around the closed blastopore in embryos of slow-developing frogs. Dorsal convergence and extension only start after blastopore closure in slow-developing frog embryos. However, in the neurulae, a gastrocoel roof plate develops, despite the accumulation of superficial mesodermal cells in the circumblastoporal collar. Embryos of all four species develop a ciliated gastrocoel roof plate at the beginning of neurulation. Accordingly, fluid-flow across the gastrocoel roof plate is likely the mechanism of left-right asymmetry patterning in these frogs, as in X. laevis and other vertebrates. A ciliated gastrocoel roof plate, with a likely origin as superficial mesoderm, is conserved in frogs belonging to four different families and with different modes of gastrulation.

  8. Circular plate capacitor with different disks

    CERN Document Server

    Paffuti, Giampiero; Di Lieto, Alberto; Maccarrone, Francesco

    2016-01-01

    In this paper we write a system of integral equations for a capacitor composed by two disks of different radii, generalizing Love's equation for equal disks. We compute the complete asymptotic form of the capacitance matrix both for large and small distances obtaining a generalization of Kirchhoff's formula for the latter case.

  9. Subnanosecond scintillation detector for high energy cosmic rays Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The task objective is to develop a gamma ray scintillator technology with subnanosecond temporal resolution and the capability to withstand unprecedented rates and...

  10. A Solid-State Sub-Nanosecond Microwave Switch

    Science.gov (United States)

    Avdochenko, B. I.; Prudaev, I. A.; Tolbanov, O. P.; Chumerin, P. Yu.; Yurchenko, V. I.

    2016-12-01

    A problem is discussed of the microwave generator power switching with the use of high-speed subnanosecond avalanche diodes. A scheme of the measurement setup, a photo of the switch design, and the results of experimental studies are presented.

  11. Sound radiation from a joint of plates of different thickness

    Science.gov (United States)

    Kirpichnikov, V. Yu.; Romanova, V. V.

    2003-09-01

    A method of solving the problem of sound radiation from a plate with elements of different thickness in its plane is proposed, and the results obtained with this method are presented. It is shown that the main sources of sound radiation are the inhomogeneous flexural fields formed in the elements on both sides of their joint.

  12. Variation in Campylobacter Mulilocus Sequence Typing Subtypes Detected on Three Different Plating Media

    Science.gov (United States)

    Introduction: There are multiple selective plating media available for detection and enumeration of naturally occurring Campylobacter. Campylobacter produce colonies with differing morphology and characteristics depending on the plating medium used. It is unclear if choice of plating medium can a...

  13. Sub-nanosecond optical diagnostics of laser-material interaction and dynamic microstructure of materials

    Energy Technology Data Exchange (ETDEWEB)

    Paisley, D.L.; Stahl, D.B.

    1993-03-01

    Several optical diagnostic techniques are used to evaluate the dynamic response of materials to intense dynamic loading and unloading, high stress and strain, and pressure. Velocity interferometry and electronic streak photography, each with sub-nanosecond time resolution, are used to record dynamic material response. Laser-launched flat plates are accelerated to 10{sup 12} m/s{sup 2} with terminal velocities >5 km/s. By impacting these plates into target samples, high strain rates (10{sup 8} sec{sup {minus}1}) and pressures >100 GPa have been generated for a duration of 0.8--5 nanoseconds. The efficacy and limitations of each technique are detailed and applications to other fields discussed.

  14. Sub-nanosecond optical diagnostics of laser-material interaction and dynamic microstructure of materials

    Energy Technology Data Exchange (ETDEWEB)

    Paisley, D.L.; Stahl, D.B.

    1993-01-01

    Several optical diagnostic techniques are used to evaluate the dynamic response of materials to intense dynamic loading and unloading, high stress and strain, and pressure. Velocity interferometry and electronic streak photography, each with sub-nanosecond time resolution, are used to record dynamic material response. Laser-launched flat plates are accelerated to 10[sup 12] m/s[sup 2] with terminal velocities >5 km/s. By impacting these plates into target samples, high strain rates (10[sup 8] sec[sup [minus]1]) and pressures >100 GPa have been generated for a duration of 0.8--5 nanoseconds. The efficacy and limitations of each technique are detailed and applications to other fields discussed.

  15. Anatomic fit of six different radial head plates: comparison of precontoured low-profile radial head plates.

    Science.gov (United States)

    Burkhart, Klaus Josef; Nowak, Tobias E; Kim, Yoon-Joo; Rommens, Pol M; Müller, Lars P

    2011-04-01

    Bulky implants may lead to symptomatic soft tissue irritation after open reduction and internal fixation of radial head and neck fractures. The purpose of our study was to compare the anatomic fit of precontoured radial head plates. We stripped 22 embalmed human cadaveric radiuses of soft tissues. We investigated 6 radial head plates: (1) the Medartis radial head buttress plate (MBP), (2) the Medartis radial head rim plate (MRP), (3) the Synthes radial neck plate (SNP), (4) the Synthes radial head plate (SHP), (5) the Acumed radial head plate (AHP), and (6) the Wright radial head plate (WHP). Each plate was applied to each radial head at the place of best fit within the safe zone. We tested 4 parameters of anatomic fit: (1) plate-to-bone distance, (2) plate contact judged by 3 different observers, (3) pin-subchondral zone distance, and (4) plate-to-bone contact after adjustment of the plates. The MBP and MRP showed the lowest profile by objective measurements, the SNP and AHP had a moderate profile, and the SHP and WHP demonstrated the bulkiest profile. The subjective assessments also demonstrated the best fit for the MBP, a good fit for the SNP, a moderate fit for the MRP and AHP, and a poor fit for the SHP and WHP. The MBP, MRP, and AHP could always provide pin-subchondral zone contact, unlike the SHP, SNP, and WHP. After bending, significant improvement of plate-to-bone distance could only be seen for the MBP, MRP, and WHP. The ranking among plates remained the same except for the WHP, which showed a significantly lower plate-to-bone distance than the SHP. Currently available radial head implants are heterogeneous. The MBP and MRP showed the lowest profile and best anatomic fit. Owing to the complex radial head anatomy, to date there is no one radial head plate that perfectly fits all radial heads. Conformance of existing plates to the radial head and neck is not perfect. Careful plate selection and modification, when necessary, may minimize interference of this

  16. Efficiencies of flat plate solar collectors at different flow rates

    DEFF Research Database (Denmark)

    Chen, Ziqian; Furbo, Simon; Perers, Bengt;

    2012-01-01

    Two flat plate solar collectors for solar heating plants from Arcon Solvarme A/S are tested in a laboratory test facility for solar collectors at Technical University of Denmark (DTU). The collectors are designed in the same way. However, one collector is equipped with an ETFE foil between...... the absorber and the cover glass and the other is without ETFE foil. The efficiencies for the collectors are tested at different flow rates. On the basis of the measured efficiencies, the efficiencies for the collectors as functions of flow rate are obtained. The calculated efficiencies are in good agreement...

  17. Vibration Analysis of Annular Sector Plates under Different Boundary Conditions

    Directory of Open Access Journals (Sweden)

    Dongyan Shi

    2014-01-01

    Full Text Available An analytical framework is developed for the vibration analysis of annular sector plates with general elastic restraints along each edge of plates. Regardless of boundary conditions, the displacement solution is invariably expressed as a new form of trigonometric expansion with accelerated convergence. The expansion coefficients are treated as the generalized coordinates and determined using the Rayleigh-Ritz technique. This work allows a capability of modeling annular sector plates under a variety of boundary conditions and changing the boundary conditions as easily as modifying the material properties or dimensions of the plates. Of equal importance, the proposed approach is universally applicable to annular sector plates of any inclusion angles up to 2π. The reliability and accuracy of the current method are adequately validated through numerical examples.

  18. PLATE

    DEFF Research Database (Denmark)

    Kling, Joyce; Hjulmand, Lise-Lotte

    2008-01-01

    ’s level of English is sufficient for the increasing number of courses offered in English each semester. This paper addresses these concerns and describes a pilot project initiated in 2003 at CBS to gauge the overall English language proficiency of those teaching content courses in English. Through......Copenhagen Business School (CBS) finds itself needing to address the issue of English-medium instruction for its increasing number of foreign exchange and full degree students. With internationalisation as a main pillar of the institution’s agenda, there are concerns whether the teaching faculty...... the Project in Language Assessment for Teaching in English (PLATE) language professionals from CBS’s Language Center observe teachers and provide feedback using evaluation criteria from the Common European Framework for Reference (CEFR) supplemented by some additional criteria which take the LSP nature...

  19. PLATE

    DEFF Research Database (Denmark)

    Kling, Joyce; Hjulmand, Lise-Lotte

    2008-01-01

    Copenhagen Business School (CBS) finds itself needing to address the issue of English-medium instruction for its increasing number of foreign exchange and full degree students. With internationalisation as a main pillar of the institution’s agenda, there are concerns whether the teaching faculty......’s level of English is sufficient for the increasing number of courses offered in English each semester. This paper addresses these concerns and describes a pilot project initiated in 2003 at CBS to gauge the overall English language proficiency of those teaching content courses in English. Through...... the Project in Language Assessment for Teaching in English (PLATE) language professionals from CBS’s Language Center observe teachers and provide feedback using evaluation criteria from the Common European Framework for Reference (CEFR) supplemented by some additional criteria which take the LSP nature...

  20. Research on Transverse Acetabular Fracture Fixation Using Different Plate Attachment Methods

    Directory of Open Access Journals (Sweden)

    Gediminas Gaidulis

    2015-03-01

    Full Text Available The article deals with the problem of transverse acetabular fracture fixation using different plate attachment methods. A 3D model of pelvis and hip joint structure was created and the design of three different fixation plates using SolidWorks was made. The plates were fixed at distances of 10, 20 and 30 mm from the acetabulum. The model was meshed into finite elements, a static external load of 2500 N was added and the analysis of stress distribution in plates and fracture displacement was performed. The obtained results showed that fracture displacement was quite similar in all fixation methods. However, the maximal stress in the nearest from the acetabulum plate was higher than yield strength. Thus, this placement is not eligible. The plate fixed at a distance of 30 mm from the acetabulum appeared the most suitable because of the smallest and symmetrical stress distribution in the plate.

  1. Biomechanical analysis of acromioclavicular joint dislocation treated with clavicle hook plates in different lengths.

    Science.gov (United States)

    Shih, Cheng-Min; Huang, Kui-Chou; Pan, Chien-Chou; Lee, Cheng-Hung; Su, Kuo-Chih

    2015-11-01

    Clavicle hook plates are frequently used in clinical orthopaedics to treat acromioclavicular joint dislocation. However, patients often exhibit acromion osteolysis and per-implant fracture after undergoing hook plate fixation. With the intent of avoiding future complications or fixation failure after clavicle hook plate fixation, we used finite element analysis (FEA) to investigate the biomechanics of clavicle hook plates of different materials and sizes when used in treating acromioclavicular joint dislocation. Using finite element analysis, this study constructed a model comprising four parts: clavicle, acromion, clavicle hook plate and screws, and used the model to simulate implanting different types of clavicle hook plates in patients with acromioclavicular joint dislocation. Then, the biomechanics of stainless steel and titanium alloy clavicle hook plates containing either six or eight screw holes were investigated. The results indicated that using a longer clavicle hook plate decreased the stress value in the clavicle, and mitigated the force that clavicle hook plates exert on the acromion. Using a clavicle hook plate material characterized by a smaller Young's modulus caused a slight increase in the stress on the clavicle. However, the external force the material imposed on the acromion was less than the force exerted on the clavicle. The findings of this study can serve as a reference to help orthopaedic surgeons select clavicle hook plates.

  2. Comparison of three different plating techniques for the dorsum of the distal radius: a biomechanical study.

    Science.gov (United States)

    Peine, R; Rikli, D A; Hoffmann, R; Duda, G; Regazzoni, P

    2000-01-01

    Three different plating techniques were used on experimentally produced dorsally displaced distal radius fractures in cadavers and were tested in 4-point bending: a AO 3.5-mm T plate (group 1), two 2. 0-mm titanium plates 60 degrees to each other (group 2), and the AO pi plate (group 3). A metaphyseal defect was simulated by a dorsally open wedge osteotomy. The tests show that the 2-mm double-plating technique has superior stiffness and statistically equivalent bending and bone gap to failure compared with the AO 3.5-mm T plate or the pi plate when applied to the unstable distal radius fracture model. (J Hand Surg 2000; 25A:29-33. Copyright 2000 by the American Society for Surgery of the Hand.).

  3. Complications during removal of conventional versus locked compression plates: is there a difference?

    Science.gov (United States)

    Neumann, Hanjo; Stadler, Anne; Heuer, Hinrich; Auerswald, Marc; Gille, Justus; Schulz, Arndt Peter; Kienast, Benjamin

    2017-08-01

    Osteosynthesis plate removal is one of the most commonly performed procedures in orthopaedic surgery. Due to technological advances and the quality of increasing osteosynthesis material, more and more locked plates have been implanted over the last 20 years. The aim of this study was to determine whether the complication rate during plate removal differs between conventional and locked plates. In this retrospective cohort study, 620 patients were included and divided into two groups based on the type of plate (locked and conventional). Technical complications during implant removal included screw breakage, destroyed screw head, implant breakage, remaining implant material, refracture, bony or soft tissue overgrowth. The following plate-associated complications were identified: osteosynthesis plate not detachable, plate bent or broken, necessity of special tools or plate loosened. Three types of screw-related complications were observed: screw not detachable, screw broken or screw dislocated. Overall, complications related to the plate or screws were documented in 110 of the 620 cases. These complications occurred in 48 of the 382 cases involving conventional osteosynthesis (7.7% of all removals, 12.6% of all conventional removals) and in 62 of the 238 cases involving locked plate osteosynthesis (10.0% of all removals, 26.1% of all locked plate removals). The statistical analysis showed a significantly higher implant-related complication rate with locked plates compared to the conventional plates (p < 0.01). Hardware removal can be a complication-afflicted operation, especially cases involving locked-plate removal should only be performed if a strong indication is evident. Possible benefits of the procedure should be considered carefully, taking the cost-benefit ratio into account.

  4. Polarization pattern of vector vortex beams generated by $q$-plates with different topological charges

    CERN Document Server

    Cardano, Filippo; Slussarenko, Sergei; Marrucci, Lorenzo; de Lisio, Corrado; Santamato, Enrico

    2012-01-01

    We describe the polarization topology of the vector beams emerging from a patterned birefringent liquid crystal plate with a topological charge $q$ at its center ($q$-plate). The polarization topological structures for different $q$-plates and different input polarization states have been studied experimentally by measuring the Stokes parameters point-by-point in the beam transverse plane. Furthermore, we used a tuned $q=1/2$-plate to generate cylindrical vector beams with radial or azimuthal polarizations, with the possibility of switching dynamically between these two cases by simply changing the linear polarization of the input beam.

  5. Polarization pattern of vector vortex beams generated by q-plates with different topological charges.

    Science.gov (United States)

    Cardano, Filippo; Karimi, Ebrahim; Slussarenko, Sergei; Marrucci, Lorenzo; de Lisio, Corrado; Santamato, Enrico

    2012-04-01

    We describe the polarization topology of the vector beams emerging from a patterned birefringent liquid crystal plate with a topological charge q at its center (q-plate). The polarization topological structures for different q-plates and different input polarization states have been studied experimentally by measuring the Stokes parameters point-by-point in the beam transverse plane. Furthermore, we used a tuned q=1/2-plate to generate cylindrical vector beams with radial or azimuthal polarizations, with the possibility of switching dynamically between these two cases by simply changing the linear polarization of the input beam.

  6. Experimental investigation of heat transfer and effectiveness in corrugated plate heat exchangers having different chevron angles

    Science.gov (United States)

    Kılıç, Bayram; İpek, Osman

    2017-02-01

    In this study, heat transfer rate and effectiveness of corrugated plate heat exchangers having different chevron angles were investigated experimentally. Chevron angles of plate heat exchangers are β = 30° and β = 60°. For this purpose, experimentally heating system used plate heat exchanger was designed and constructed. Thermodynamic analysis of corrugated plate heat exchangers having different chevron angles were carried out. The heat transfer rate and effectiveness values are calculated. The experimental results are shown that heat transfer rate and effectiveness values for β = 60° is higher than that of the other. Obtained experimental results were graphically presented.

  7. Simulation of subnanosecond streamers in atmospheric-pressure air: Effects of polarity of applied voltage pulse

    Science.gov (United States)

    Babaeva, N. Yu.; Naidis, G. V.

    2016-08-01

    Results of simulation of subnanosecond streamer propagation in corona gap configuration, obtained in the framework of 2D fluid model, are presented. Effects related with the polarity of a voltage pulse applied to the stressed electrode are discussed. It is argued that these effects (dependence of the discharge current and propagation velocity on the polarity of applied voltage) observed in experiments can be attributed to the difference in initial (preceding the streamer formation) distributions of charged species inside the gap. This difference can be caused by preionization (at negative polarity) of the gas inside the discharge gap by runaway electrons. Calculated streamers have large widths (up to 1 cm) and move with velocities in the range of 109-1010 cm s-1, similar to experimental data.

  8. COMPARATIVE FIELD EXPERIMENTAL INVESTIGATIONS OF DIFFERENT FLAT PLATE SOLAR COLLECTORS

    Directory of Open Access Journals (Sweden)

    Guangming Chen

    2015-12-01

    Full Text Available Full-scale traditional metal solar collectors and solar collector specimens fabricated from polymeric materials were investigated in the present study. A polymeric collector is 67.8% lighter than a traditional metal solar collector, and a metal solar collector with transparent plastic covering is 40.3% lighter than a traditional metal solar collector. Honeycomb multichannel plates made from polycarbonate were chosen to create a polymeric solar collector. A test rig for the natural circulation of the working fluid in a solar collector was built for a comparative experimental investigation of various solar collectors operating at ambient conditions. It was shown experimentally that the efficiency of a polymeric collector is 8–15% lower than the efficiency of a traditional collector.

  9. Sub-nanosecond Electron Emission from Electrically Gated Field Emitting Arrays

    CERN Document Server

    Paraliev, M; Gough, C; Kirk, E; Ivkovic, S

    2011-01-01

    Field Emitting Arrays (FEAs) are a promising alternative to the conventional cathodes in different vacuum electronic devices such as traveling wave tubes, electron accelerators and etc. Electrical gating and modulation capabilities, together with the ability to produce stable and homogeneous electron beam in high electric field environment are the key requirements for their practical application. Due to relatively high gate capacitance, fast controlling of FEA emission is difficult. In order to achieve sub-nanosecond, electrically controlled, FEA based electron emission a special pulsed gate driver was developed. Bipolar high voltage (HV)pulses are used to rapidly inject and remove charge form FEA gate electrode controlling quickly electron extraction gate voltage. Short electron emission pulses (<600 ps FWHM) were observed in low and high gradient (up to 12 MV/m) environment. First attempts were made to combine FEA based electron emission with radio frequency acceleration structures (1.5 GHz) using pulsed...

  10. Evaluation of factors affecting plate waste of inpatients in different healthcare settings

    Directory of Open Access Journals (Sweden)

    Antonio Valero Díaz

    2013-04-01

    Full Text Available Introduction/aims: Satisfaction of inpatients with served food within a hospital care system still constitutes one of the main attempts to modernize food services. The impact of type of menu, food category, hospital centre and timetable on the meals wastage produced in different Spanish healthcare settings, was evaluated. Methods: Meal wastage was measured through a semiquantitative 5-point scale ("nothing on plate"; "¼ on plate"; "half on plate"; "¾ on plate" and "all on plate". The study was carried out in two periods of three months each in 2010 and 2011. A trained person took charge of measuring plate waste classified into 726 servings belonging to 11 menus. In total 31,392 plates were served to 7,868 inpatients. A Kruskal-Wallis non-parametric test (P 0.05. Conclusion: Visual inspections of plate waste might be useful to optimize type and quality of menus served. The type of menu served and the food category could have a great influence on food acceptability by the inpatients studied.

  11. Fiber Coupled Pulse Shaper for Sub-Nanosecond Pulse Lidar Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase II effort will develop an all-diode laser and fiber optic based, single frequency, sub-nanosecond pulsed laser source...

  12. Subnanosecond current mode detectors for prompt physical process diagnosis

    Institute of Scientific and Technical Information of China (English)

    1999-01-01

    For prompt physical diagnosis, several types of subnanosecond current mode detectors have been developed,including scintillator detectors with large linear output current,GaAs:Cr and InP:Fe photoconductor detectors(PCD), and X-ray diodes(XRD), etc. The characteristic of scintillation light of BaF2 crystal doped with La and of plastic scintillator ST1422 with slow component quencher are described. As for the photoconductor detectors, the main performance of neutron damaged GaAs:Cr and InP:Fe were studied. In addition, the spectral response of an XRD with coaxial leading-out end was also studied. These detectors have been successfully applied to nuclear test diagnosis and ICF research.

  13. Development of bipolar plates with different flow channel configurations for fuel cells

    Science.gov (United States)

    Boddu, Rajesh; Marupakula, Uday Kumar; Summers, Benjamin; Majumdar, Pradip

    Bipolar plates include separate gas flow channels for anode and cathode electrodes of a fuel cell. These gases flow channels supply reactant gasses as well as remove products from the cathode side of the fuel cell. Fluid flow, heat and mass transport processes in these channels have significant effect on fuel cell performance, particularly to the mass transport losses. The design of the bipolar plates should minimize plate thickness for low volume and mass. Additionally, contact faces should provide a high degree of surface uniformity for low thermal and electrical contact resistances. Finally, the flow fields should provide for efficient heat and mass transport processes with reduced pressure drops. In this study, bipolar plates with different serpentine flow channel configurations are analyzed using computational fluid dynamics modeling. Flow characteristics including variation of pressure in the flow channel across the bipolar plate are presented. Pressure drop characteristics for different flow channel designs are compared. Results show that with increased number of parallel channels and smaller sizes, a more effective contact surface area along with decreased pressured drop can be achieved. Correlations of such entrance region coefficients will be useful for the PEM fuel cell simulation model to evaluate the affects of the bipolar plate design on mass transfer loss and hence on the total current and power density of the fuel cell.

  14. Subnanosecond fluorescence spectroscopy of human serum albumin as a method to estimate the efficiency of the depression therapy

    Science.gov (United States)

    Syrejshchikova, T. I.; Gryzunov, Yu. A.; Smolina, N. V.; Komar, A. A.; Uzbekov, M. G.; Misionzhnik, E. J.; Maksimova, N. M.

    2010-05-01

    The efficiency of the therapy of psychiatric diseases is estimated using the fluorescence measurements of the conformational changes of human serum albumin in the course of medical treatment. The fluorescence decay curves of the CAPIDAN probe (N-carboxyphenylimide of the dimethylaminonaphthalic acid) in the blood serum are measured. The probe is specifically bound to the albumin drug binding sites and exhibits fluorescence as a reporter ligand. A variation in the conformation of the albumin molecule substantially affects the CAPIDAN fluorescence decay curve on the subnanosecond time scale. A subnanosecond pulsed laser or a Pico-Quant LED excitation source and a fast photon detector with a time resolution of about 50 ps are used for the kinetic measurements. The blood sera of ten patients suffering from depression and treated at the Institute of Psychiatry were preliminary clinically tested. Blood for analysis was taken from each patient prior to the treatment and on the third week of treatment. For ten patients, the analysis of the fluorescence decay curves of the probe in the blood serum using the three-exponential fitting shows that the difference between the amplitudes of the decay function corresponding to the long-lived (9 ns) fluorescence of the probe prior to and after the therapeutic procedure reliably differs from zero at a significance level of 1% ( p < 0.01).

  15. Room-temperature subnanosecond waveguide lasers in Nd:YVO4 Q-switched by phase-change VO2: A comparison with 2D materials

    Science.gov (United States)

    Nie, Weijie; Li, Rang; Cheng, Chen; Chen, Yanxue; Lu, Qingming; Romero, Carolina; Vázquez de Aldana, Javier R.; Hao, Xiaotao; Chen, Feng

    2017-01-01

    We report on room-temperature subnanosecond waveguide laser operation at 1064 nm in a Nd:YVO4 crystal waveguide through Q-switching of phase-change nanomaterial vanadium dioxide (VO2). The unique feature of VO2 nanomaterial from the insulating to metallic phases offers low-saturation-intensity nonlinear absorptions of light for subnanosecond pulse generation. The low-loss waveguide is fabricated by using the femtosecond laser writing with depressed cladding geometry. Under optical pump at 808 nm, efficient pulsed laser has been achieved in the Nd:YVO4 waveguide, reaching minimum pulse duration of 690 ps and maximum output average power of 66.7 mW. To compare the Q-switched laser performances by VO2 saturable absorber with those based on two-dimensional materials, the 1064-nm laser pulses have been realized in the same waveguide platform with either graphene or transition metal dichalcogenide (in this work, WS2) coated mirror. The results on 2D material Q-switched waveguide lasers have shown that the shortest pulses are with 22-ns duration, whilst the maximum output average powers reach ~161.9 mW. This work shows the obvious difference on the lasing properties based on phase-change material and 2D materials, and suggests potential applications of VO2 as low-cost saturable absorber for subnanosecond laser generation. PMID:28383017

  16. Room-temperature subnanosecond waveguide lasers in Nd:YVO4 Q-switched by phase-change VO2: A comparison with 2D materials

    Science.gov (United States)

    Nie, Weijie; Li, Rang; Cheng, Chen; Chen, Yanxue; Lu, Qingming; Romero, Carolina; Vázquez de Aldana, Javier R.; Hao, Xiaotao; Chen, Feng

    2017-04-01

    We report on room-temperature subnanosecond waveguide laser operation at 1064 nm in a Nd:YVO4 crystal waveguide through Q-switching of phase-change nanomaterial vanadium dioxide (VO2). The unique feature of VO2 nanomaterial from the insulating to metallic phases offers low-saturation-intensity nonlinear absorptions of light for subnanosecond pulse generation. The low-loss waveguide is fabricated by using the femtosecond laser writing with depressed cladding geometry. Under optical pump at 808 nm, efficient pulsed laser has been achieved in the Nd:YVO4 waveguide, reaching minimum pulse duration of 690 ps and maximum output average power of 66.7 mW. To compare the Q-switched laser performances by VO2 saturable absorber with those based on two-dimensional materials, the 1064-nm laser pulses have been realized in the same waveguide platform with either graphene or transition metal dichalcogenide (in this work, WS2) coated mirror. The results on 2D material Q-switched waveguide lasers have shown that the shortest pulses are with 22-ns duration, whilst the maximum output average powers reach ~161.9 mW. This work shows the obvious difference on the lasing properties based on phase-change material and 2D materials, and suggests potential applications of VO2 as low-cost saturable absorber for subnanosecond laser generation.

  17. Variation in Campylobacter MLST Subtypes Detected from Chickens on Three Different Plating Media

    Science.gov (United States)

    The objective of this study was to compare subtypes of Campylobacter jejuni and coli detected on three discreet selective Campylobacter plating media to determine if different media select for different subtypes. Fifty ceca and fifty carcasses (n=100, representing 50 flocks) were collected from the...

  18. SOLUTION OF DIFFERENT HOLES SHAPE BORDERS OF FIBRE REINFORCED COMPOSITE PLATES BY INTEGRAL EQUATIONS

    Institute of Scientific and Technical Information of China (English)

    LI Cheng; ZHENG Yanping; CHEN Zhongzhong

    2007-01-01

    Accurate boundary conditions of composite material plates with different holes are founded to settle boundary condition problems of complex holes by conformal mapping method upon the nonhomogeneous anisotropic elastic and complex function theory. And then the two stress functions required were founded on Cauchy integral by boundary conditions. The final stress distributions of opening structure and the analytical solution on composite material plate with rectangle hole and wing manholes were achieved. The influences on hole-edge stress concentration factors are discussed under different loads and fiber direction cases, and then contrast calculates are carried through FEM.

  19. Generation of sub-nanosecond pulses using peaking capacitor

    Directory of Open Access Journals (Sweden)

    Madhu Palati

    2017-05-01

    Full Text Available This paper discusses the analysis, simulation and design of a peaking circuit comprising of a peaking capacitor, spark gap and load circuit. The peaking circuit is used along with a 200 kV, 20 J Marx generator for generation of sub-nanosecond pulses. A high pressure chamber to accommodate the peaking circuit was designed and fabricated and tested upto a pressure of 70 kg/cm2. Total estimated values of the capacitance and inductance of the peaking circuit are 10 pF and 72 nH respectively. At full charging voltage, the peaking capacitor gets charged to a peak voltage of 394.6 kV in 15 ns. The output switch is closed at this instant. From Analysis & Simulation, the output current & rise time (with a matched load of 85 Ω are 2.53 kA and 0.62 ns.

  20. Applications of a General Finite-Difference Method for Calculating Bending Deformations of Solid Plates

    Science.gov (United States)

    Walton, William C., Jr.

    1960-01-01

    This paper reports the findings of an investigation of a finite - difference method directly applicable to calculating static or simple harmonic flexures of solid plates and potentially useful in other problems of structural analysis. The method, which was proposed in doctoral thesis by John C. Houbolt, is based on linear theory and incorporates the principle of minimum potential energy. Full realization of its advantages requires use of high-speed computing equipment. After a review of Houbolt's method, results of some applications are presented and discussed. The applications consisted of calculations of the natural modes and frequencies of several uniform-thickness cantilever plates and, as a special case of interest, calculations of the modes and frequencies of the uniform free-free beam. Computed frequencies and nodal patterns for the first five or six modes of each plate are compared with existing experiments, and those for one plate are compared with another approximate theory. Beam computations are compared with exact theory. On the basis of the comparisons it is concluded that the method is accurate and general in predicting plate flexures, and additional applications are suggested. An appendix is devoted t o computing procedures which evolved in the progress of the applications and which facilitate use of the method in conjunction with high-speed computing equipment.

  1. Fabricating feeding plate in CLP infants with two different material: A series of case report

    Directory of Open Access Journals (Sweden)

    R Gupta

    2012-01-01

    Full Text Available Feeding is a family′s biggest concerns when a child is born with cleft lip and/or palate. The goal for that child is to have as near normal feeding as possible. This report presents fabrication of feeding plates in two infants born with cleft lip and palate using two different materials.

  2. Bending Analysis of Functionally Graded Plates in the Context of Different Theories of Thermoelasticity

    Directory of Open Access Journals (Sweden)

    A. M. Zenkour

    2009-01-01

    Full Text Available The quasistatic bending response is presented for a simply supported functionally graded rectangular plate subjected to a through-the-thickness temperature field under the effect of various theories of generalized thermoelasticity, namely, classical dynamical coupled theory, Lord and Shulman's theory with one relaxation time, and Green and Lindsay's theory with two relaxation times. The generalized shear deformation theory obtained by the first author is used. Material properties of the plate are assumed to be graded in the thickness direction according to a simple exponential law distribution in terms of the volume fractions of the constituents. The numerical illustrations concern quasistatic bending response of functionally graded square plates with two constituent materials are studied using the different theories of generalized thermoelasticity

  3. Experimental Simulation of Natural Heat Convection from Finned Vertical Plate with Different Inclinations

    Directory of Open Access Journals (Sweden)

    Saad Najeeb Shehab

    2016-09-01

    Full Text Available In this work an experimental simulation is made to predict the performance of steady-state natural heat convection along heated finned vertical base plate to ambient air with different inclination angles and configurations of fin array. Two types of fin arrays namely vertical fins array and V-fins array on heated vertical base plate are used with different heights and spaces. The influence of inclination angle of the plate , configuration of fins array and fin geometrical parameters such as fin height and fin spacing on the temperature distribution, base convection heat transfer coefficient and average Nusselt number have been plotted and discussed. The experimental data are correlated to a formula between average Nusselt number versus Rayleigh number for vertical plate and vertical fins array. The results indicate that the configuration of V-fins array gave best natural-convection heat transfer performance as base heat transfer coefficient about 20% greater compared with vertical fins array. Experimental simulation data and correlations of the present work are compared with a previous works shows good agreement

  4. Experimental setup for temporally and spatially resolved ICCD imaging of (sub)nanosecond streamer plasma

    Science.gov (United States)

    Huiskamp, T.; Sengers, W.; Pemen, A. J. M.

    2016-12-01

    Streamer discharges are efficient non-thermal plasmas for air purification and can be generated in wire-cylinder electrode structures (the plasma reactor). When (sub)nanosecond high-voltage pulses are used to generate the plasma, components like a plasma reactor behave as transmission lines, where transmission times and reflections become important. We want to visually study the influence of these transmission-line effects on the streamer development in the reactor. Therefore, we need a unique experimental setup, which allows us to image the streamers with nanosecond time resolution over the entire length of the plasma reactor. This paper describes the setup we developed for this purpose. The setup consists of a large frame in which a specially designed plasma reactor can be mounted and imaged from below by an intensified charge-coupled device (ICCD) camera. This camera is mounted on a platform which can be moved by a stepper motor. A computer automates all the experiments and controls the camera movement, camera settings, and the nanosecond high-voltage pulse source we use for the experiments. With the automated setup, we can make ICCD images of the entire plasma reactor at different instances of time with nanosecond resolution (with a jitter of less than several hundreds of picoseconds). Consequently, parameters such as the streamer length and width can be calculated automatically.

  5. Matching a (sub)nanosecond pulse source to a corona plasma reactor

    Science.gov (United States)

    Huiskamp, T.; Beckers, F. J. C. M.; Hoeben, W. F. L. M.; van Heesch, E. J. M.; Pemen, A. J. M.

    2016-10-01

    In this paper we investigate the energy transfer from the pulses of a (sub)nanosecond pulse source to the plasma in a corona-plasma reactor. This energy transfer (or ‘matching’) should be as high as possible. We studied the effect of multiple parameters on matching, such as the reactor configuration, the pulse duration and amplitude and the energy density. The pulse reflection on the reactor interface has a significant influence on matching, and should be as low as possible to transfer the most energy into the reactor. We developed a multiple-wire inner conductor for the reactor which decreases the vacuum impedance of the reactor to decrease the pulse reflection on the reactor interface while maintaining a high electric field on the wire. The results were very encouraging and showed an energy transfer efficiency of over 90 percent. The matching results further show that there is only a small effect on the matching between different wire diameters. In addition, a long reactor and a long pulse result in the best matching due to the more intense plasma that is generated in these conditions. Finally, even without the multiple-wire reactor, we are able to achieve a very good matching (over 80 percent) between our pulse source and the reactor.

  6. On the Acoustic Absorption of Porous Materials with Different Surface Shapes and Perforated Plates

    Science.gov (United States)

    CHEN, WEN-HWA; LEE, FAN-CHING; CHIANG, DAR-MING

    2000-10-01

    In architectural acoustic design, perforated plates are often used to protect porous materials from erosion. Although porous materials are usually applied to passive noise control, the effects of their surface shapes are seldom studied. To study the acoustic absorption of porous materials with different surface shapes and perforated plates, an efficient finite element procedure, which is derived by the Galerkin residual method and Helmholtz wave propagation equation, is used in this work. The two-microphone transfer function method and the modified Ingard and Dear impedance tube testing system are employed to measure the parameters deemed necessary for the finite element analysis, such as complex wave propagation constant, characteristic impedance and flow resistivity. For verifying the finite element results, the two-microphone transfer function method is also applied to measure the absorption coefficients of the discussed acoustic absorbers. Four surface shapes of commercially available porous materials, i.e., triangle, semicircle, convex rectangle and plate shapes, are chosen for analysis. The porosity of perforated plates is then evaluated. Finally, the distinct effect of the flow resistivity of porous materials on the acoustic absorption is demonstrated.

  7. Response of a circular steel plate with different weld geometries subject to impact loading

    Directory of Open Access Journals (Sweden)

    Meyer L.W.

    2012-08-01

    Full Text Available The dynamic response of clamped circular steel plates was experimentally investigated under impact loading. The experiments were performed using a high energy drop weight machine with a 5 ton drop weight, which falls from a height of 0.8 m and results in a total impact energy of 40 kJ. Target plates of 10 mm thickness and 580 mm diameter were welded in three different geometrical configurations of weld elements on the lower side. The impact process was carried out using a hemispherical punch. The force was registered by strain gages on the punch. A full dynamic strain field measurement was applied on the tension side using two high speed cameras. The evaluation of the strain field was carried out with the speckle photography technique. The effect of cracks and welding on the deformation and failure behavior was studied using pre-cracked disks and plates with welded webs, welded circular discs and also with a weld seam only. The failure of the plates was registered using the high speed cameras and from the force signal. The results are analyzed and discussed regarding the behavior of the material and component under high rate loading.

  8. Effect of different heating methods on deformation of metal plate under upsetting mechanism in laser forming

    Science.gov (United States)

    Shi, Yongjun; Liu, Yancong; Yi, Peng; Hu, Jun

    2012-03-01

    In a laser forming process, different forming mechanisms have different deformation behaviors. The aim of laser forming is to acquire plane strain under an upsetting mechanism, while a plate undergoes a small bending deformation. In some industrial applications, the bending strain should not occur. To achieve high-precision forming, the deformation behaviors of a metal plate when an upsetting mechanism plays a dominant role are studied in the paper. Several heating methods are proposed to reduce the plane strain difference along the thickness direction and little bending deformation resulting from a small temperature difference between the top and bottom surfaces of the plate. The results show that negligible bending deformation and a uniform plastic plane strain field can be obtained by simultaneously heating the top and bottom surfaces with the same process parameters. A conventional scanning method needs a larger spot diameter and slower scanning speed under the upsetting mechanism, but a smaller spot diameter and quicker scanning speed may be selected using the simultaneous heating method, which can greatly widen the potential scope of process parameters.

  9. Free Vibration and Bending Behaviour of CNT Reinforced Composite Plate using Different Shear Deformation Theory

    Science.gov (United States)

    Mehar, K.; Panda, S. K.

    2016-02-01

    In the present study, the free vibration and the bending behaviour of carbon nanotube reinforced composite plate are computed using three different shear deformation theories under thermal environment. The material properties of carbon nanotube and matrix are assumed to be temperature-dependent, and the extended rule of mixture is used to compute the effectivematerial properties of the composite plate. The convergence and validity of the present modelalso have been checked by computing the wide variety of the numerical example. The applicability of the proposed higher-order models has been highlighted by solving the wide variety of examples for different geometrical and material parameters underelevated thermal environment.The responses are also examined using the simulation model developed in commercial finite element package (ANSYS).

  10. Mockups of blanket cooling plates manufactured in different diffusion welding setups

    Science.gov (United States)

    Weth, A. von der; Aktaa, J.

    2009-04-01

    The high amount of energy applied to the structural elements of a future fusion power plant results in the need of using plates with meandering cooling channels. Of the different proposals [J.-F. Salavy, G. Aiello, P. Aubert, L.V. Boccaccini, M. Daichendt, G. De Dinechin, E. Diegele, L.M. Giancarli, R. Lässer, H. Neuberger, Y. Poitevin, Y. Stephan, G. Rampal, E. Rigal, J. Nucl. Mater., 386-388 (2009) 922. [1

  11. Influence of Different Combinations of Explosively Welded Plates with the Same Areal Density on Their Antipenetration Performance

    Science.gov (United States)

    Wang, J.; Zhou, N.; Peng, C.

    2014-11-01

    In order to analyze the influence of different thickness distributions on the antipenetration performance of layered plates with a good surface-to-surface combination, five types of two-layer steel/aluminum and three-layer steel/aluminum/steel plates with the same areal density were manufactured by the method of explosive welding. Ballistic experiments and numerical simulation were performed to study the antipenetration performance of the plates impacted by a spherical steel projectile of diameter 8 mm. A 14.5-mm riffled gun was used to launch the projectile, and the numerical simulation were carried out by using the LS-DYNA 3D explicit finite-element code. Effects of the number of layers, their thickness distribution, and total thickness on the antipenetration performance of the layered plates were investigated. Results showed that the antipenetration performance of the multilayer plates was better than that of a monolithic plate with the same areal density — the ballistic limit speed of the two-layer and three-layer plates, on the average, increased by 9.6 and 19.9% compared with that of the monolithic one. In addition, the antipenetration performance of the three-layer plates was better than that of the two-layer ones if the thickness of the steel and aluminum plates was same. The influence of layer thickness distribution on the antipenetration performance was more pronounced for the two-layer plates.

  12. Experimental fuel cell performance analysis under different operating conditions and bipolar plate designs

    Energy Technology Data Exchange (ETDEWEB)

    Iranzo, Alfredo; Pino, Javier; Rosa, Felipe [Energy Engineering Department, School of Engineering, University of Seville, Camino de los Descubrimientos s/n, 41092 Seville (Spain); Munoz, Miguel; Lopez, Eduardo [INTA - National Institute for Aerospace Technology, Ctra. San Juan del Puerto-Matalascanas km 33, 21130 Mazagon (Huelva) (Spain)

    2010-10-15

    This work presents experimental performance results for a 50 cm{sup 2} Polymer Electrolyte Membrane (PEM) Fuel Cell, including polarization curves and Electrochemical Impedance Spectroscopy (EIS) analysis of the Fuel Cell. EIS results were used for the determination of the cell ohmic resistance as well as charge transfer resistances under different operating conditions. Different combinations of operating conditions and bipolar plate designs were analysed. In particular, the effect of the cathode oxygen concentration, reactant gases humidification, and bipolar plate (BP) design were assessed. Butler-Volmer (BV) kinetic parameters such as the charge transfer coefficient were also determined from Tafel plots. The electronic contact resistances were measured for both Bipolar Plate designs, and the membrane protonic resistances were calculated. Its dependence on the BP flow field design and operating conditions is addressed. The results obtained in this work are aimed both at gaining insight into the fundamental processes determining the fuel cell performance, and at determining parameters needed for Computational Fuel Cell Dynamics (CFCD) numerical simulations. (author)

  13. Investigation of crystallization and amorphization dynamics of phase-change thin films by subnanosecond laser pulses.

    Science.gov (United States)

    Kieu, Khanh; Narumi, Kenji; Mansuripur, Masud

    2006-10-20

    We report experimental results on amorphization and crystallization dynamics of reversible phase-change (PC) thin-film samples, GeSbTe and GeBiTe, for optical disk data storage. The investigation was conducted with subnanosecond laser pulses using a pump-and-probe configuration. Amorphization of the crystalline films could be achieved with a single subnanosecond laser pulse; the amorphization dynamics follow closely the temperature kinetics induced in the irradiated spot. As for crystallization of the samples initially in the amorphous state, a single subnanosecond pulse was found to be insufficient to fully crystallize the irradiated spot, but we could crystallize the PC film (in the area under the focused spot) by applying multiple short pulses. Our multipulse studies reveal that the GeSbTe crystallization is dominated by the growth of nuclei whose initial formation is slow but, once formed, their subsequent growth (under a sequence of subnanosecond pulses) happens quickly. In the case of GeBiTe samples, the crystalline nuclei appear to be present in the material initially, as they grow immediately upon illumination with laser pulses. Whereas our amorphous GeSbTe samples required approximately 200 pulses for full crystallization, for the GeBiTe samples approximately 15 pulses sufficed.

  14. FINITE DIFFERENCE ANALYSIS OF ACOUSTIC REFLECTION AND RADIATION FROM FLUID-LOADED PLATES

    Institute of Scientific and Technical Information of China (English)

    赵汉中

    2003-01-01

    A finite difference/boundary integral procedure to determine the acoustic reflected pressure from a fluid-loaded bi-laminate plate is described. The bi-laminate is composed of a piezoelectric layer and an elastic layer in contact with the fluid. The plate is either of finite length and held at its two ends in an acoustically hard baffle or of infinite length with periodically etched electrodes.In the numerical model, the fluid pressure at fluid/solid interface is replaced by a continuum of point sources weighted by the normal acceleration of the elastic plate, and the governing equation system is solved in the solid domain. It is demonstrated that an appropriate applied voltage potential across the baffled piezoelectric layer has the effect of cancelling the reflected pressure at any chosen field points,and a piecewise constant voltage potential with properly chosen amplitude and phase in the periodic structure has the effect of cancelling the fundamental propagating mode of the reflected waves.

  15. Reinforcement of a plate weakened by multiple holes with several patches for different types of plate-patch attachment

    KAUST Repository

    Zemlyanova, A.

    2014-01-24

    The most general situation of the reinforcement of a plate with multiple holes by several patches is considered. There is no restriction on the number and the location of the patches. Two types of patch attachment are considered: only along the boundary of the patch or both along the boundary of the patch and the boundaries of the holes which this patch covers. The unattached boundaries of the holes may be loaded with given in-plane stresses. The mechanical problem is reduced to a system of singular integral equations which can be further reduced to a system of Fredholm equations. A new numerical procedure for the solution of the system of singular integral equations is proposed in this paper. It is demonstrated on numerical examples that this procedure has advantages in the case of multiple patches and holes and allows achievement of better numerical convergence with less computational effort.

  16. Experimental analysis of DBD plasma jet properties using different gases and two kinds of transfer plate

    CERN Document Server

    Nascimento, Fellype do; Machida, Munemasa

    2015-01-01

    Dielectric Barrier Discharge (DBD) plasma jets has been studied extensively in recent years because of its wide range of applications. DBD plasmas can be produced using many different gases and can be applied to a broad variety of surfaces and substrates. In this work, we provide a comparison of DBD plasmas generated using argon (Ar), helium (He) and nitrogen (N2), as well as their mixtures with water vapor in order to know how some plasma properties are affected by the use of different gases. All plasmas were studied in two different conditions, using a transfer plate made of a conductive material and using a transfer plate made of an insulating one. We observed that the processes of excitation and ionization of nitrogen molecules by direct collisions with Ar or He are more evident and significant in He plasmas, which means that He atoms in metastable states have greater ability to transfer energy to molecules of nitrogen in the plasma. The collisions of He atoms in metastable states with N2 molecules determ...

  17. Cytotoxicity difference of 316L stainless steel and titanium reconstruction plate

    Directory of Open Access Journals (Sweden)

    Ni Putu Mira Sumarta

    2011-03-01

    Full Text Available Background: Pure titanium is the most biocompatible material today and used as a gold standard for metallic implants. However, stainless steel is still being used as implants because of its strength, ductility, lower price, corrosion resistant and biocompatibility. Purpose: This study was done to revealed the cytotoxicity difference between reconstruction plate made of 316L stainless steel and of commercially pure (CP titanium in baby hamster kidney-21 (BHK-21 fibroblast culture through MTT assay. Methods: Eight samples were prepared from reconstruction plates made of stainless steel type 316L grade 2 (Coen’s reconstruction plate® that had been cut into cylindrical form of 2 mm in diameter and 3 mm long. The other one were made of CP titanium (STEMA Gmbh® of 2 mm in diameter and 2,2 mm long; and had been cleaned with silica paper and ultrasonic cleaner, and sterilized in autoclave at 121° C for 20 minutes.9 Both samples were bathed into microplate well containing 50 μl of fibroblast cells with 2 x 105 density in Rosewell Park Memorial Institute-1640 (RPMI-1640 media, spinned at 30 rpm for 5 minutes. Microplate well was incubated for 24 and 48 hours in 37° C. After 24 hours, each well that will be read at 24 hour were added with 50 μl solution containing 5mg/ml MTT reagent in phosphate buffer saline (PBS solutions, then reincubated for 4 hours in CO2 10% and 37° C. Colorometric assay with MTT was used to evaluate viability of the cells population after 24 hours. Then, each well were added with 50 μl dimethyl sulfoxide (DMSO and reincubated for 5 minutes in 37° C. the wells were read using Elisa reader in 620 nm wave length. Same steps were done for the wells that will be read in 48 hours. Each data were tabulated and analyzed using independent T-test with significance of 5%. Results: This study showed that the percentage of living fibroblast after exposure to 316L stainless steel reconstruction plate was 61.58% after 24 hours and 62

  18. Reinforcement of a plate weakened by multiple holes with several patches for different types of a plate-patch attachment

    CERN Document Server

    Zemlyanova, A Y

    2012-01-01

    The most general situation of the reinforcement of a plate with multiple holes by several patches is considered. There is no restriction on the number and the location of the patches. Two types of the patch attachment are considered: only along the boundary of the patch or both along the boundary of the patch and the boundaries of the holes which this patch covers. The unattached boundaries of the holes may be loaded with given in-plane stresses. The mechanical problem is reduced to the system of singular integral equations which can be further reduced to the system of Fredholm equations. A new numerical procedure for the solution of the system of singular integral equations is proposed in this paper. It can be observed that this procedure provides a noticeable improvement from the one presented in Zemlyanova \\cite{Zem2007}, Zemlyanova and Silvestrov \\cite{ZemSil2007}, \\cite{ZemSil2009} and allows to achieve a significantly better numerical convergence with less computational effort.

  19. Calculations to compare different ways of modelling the plate geometry cells of the Zebra fast critical assembly, MZA

    Energy Technology Data Exchange (ETDEWEB)

    Rowlands, John, E-mail: rowlandsjl@aol.com

    2009-03-15

    The core region cells of the Zebra fast critical assembly MZA comprise 14 plates in a square steel tube, with 12 cells being stacked axially to form the core section of the assembly. The cells can be modelled in different levels of detail, ranging from a three-dimensional representation in which the core (The word core is used to describe both the region of a plate containing the main material, such as plutonium, UO{sub 2} or sodium, and the region of the assembly containing fissile material cells.) and canning regions of the plates and the void gaps between the edges of the plates and the steel tube, and between tubes, are represented. Simplified models include a three-dimensional representation in which the void regions are combined with the tube material. A further simplified three-dimensional model, called the MURAL model, represents the core regions of the plates but homogenises the canning, tube material and void regions. Two types of one-dimensional slab geometry model are found in the literature, one in which the materials are homogenised within each of the three axial slab regions of a canned plate (plate core and upper and lower canning regions) and a further simplified version in which the plate is modelled as a single region, the compositions being averaged over the whole thickness of the plate, comprising the plate core material, the canning and the tube material. MONK Monte Carlo calculations have been made for each of these models, and also for the fully homogenised cells, and the k-effective values, core sodium void reactivities and reaction rate ratios are compared.

  20. Experimental study on condensation heat transfer of steam on vertical titanium plates with different surface energies

    Energy Technology Data Exchange (ETDEWEB)

    Baojin, Qi; Li, Zhang; Hong, Xu; Yan, Sun [State-Key Laboratory of Chemical Engineering, School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai 200237 (China)

    2011-01-15

    Visual experiments were employed to investigate heat transfer characteristics of steam on vertical titanium plates with/without surface modifications for different surface energies. Stable dropwise condensation and filmwise condensation were achieved on two surface modification titanium plates, respectively. Dropwise and rivulet filmwise co-existing condensation form of steam was observed on unmodified titanium surfaces. With increase in the surface subcooling, the ratio of area ({eta}) covered by drops decreased and departure diameter of droplets increased, resulting in a decrease in condensation heat transfer coefficient. Condensation heat transfer coefficient decreased sharply with the values of {eta} decreasing when the fraction of the surface area covered by drops was greater than that covered by rivulets. Otherwise, the value of {eta} had little effect on the heat transfer performance. Based on the experimental phenomena observed, the heat flux through the surface was proposed to express as the sum of the heat flux through the dropwise region and rivulet filmwise region. The heat flux through the whole surface was the weighted mean value of the two regions mentioned above. The model presented explains the gradual change of heat transfer coefficient for transition condensation with the ratio of area covered by drops. The simulation results agreed well with the present experimental data when the subcooling temperature is lower than 10 C. (author)

  1. Effect of annealing on two different niobium-clad stainless steel PEMFC bipolar plate materials

    Institute of Scientific and Technical Information of China (English)

    Sung-Tae HONG; Dae-Wook KIM; Yong-Joo YOU; K.Scott WEIL

    2009-01-01

    Niobium (Nb)-clad stainless steels(SS) produced via roll bonding are being considered for use in the bipolar plates of polymer electrolyte membrane fuel celI(PEMFC) stacks. Because the roll bonding process induces substantial work hardening in the constituent materials, thermal annealing is used to restore ductility to the clad sheet so that it can be subsequently blanked, stamped and dimpled in forming the final plate component. Two roll bonded materials, niobium clad 340L stainless steel (Nb/340L SS) and niobium clad 434 stainless steel (Nb/434 SS) were annealed under optimized conditions prescribed by the cladding manufacturer. Comparative mechanical testing conducted on each material before and after annealing shows significant improvement in ductility in both cases. However, corresponding microstructural analyses indicate an obvious difference between the two heat treated materials. During annealing, an interlayer with thick less than 1 μm forms between the constituent layers in the Nb/340L SS, whereas no interlayer is found in the annealed Nb/434 SS material. Prior work suggests that internal defects potentially can be generated in such an interlayer during metal forming operations. Thus, Nb/434 SS may be the preferred candidate material for this application.

  2. EVALUATION OF TERMINAL VERTEBRAL PLATE ON CERVICAL SPINE AT DIFFERENT AGE GROUPS AND ITS CORRELATION WITH INTERVERTEBRAL DISC THICKNESS

    Science.gov (United States)

    Luiz Vieira, Juliano Silveira; da Silva Herrero, Carlos Fernando Pereira; Porto, Maximiliano Aguiar; Nogueira Barbosa, Marcello Henrique; Garcia, Sérgio Britto; Zambelli Ramalho, Leandra Náira; Aparecido Defino, Helton Luiz

    2015-01-01

    To evaluate, by means of histomorphometry, terminal vertebral plate thickness, intervertebral disc thickness and its correlation on different age groups, seeking to identify its correlation. Methods: C4-C5 and C5-C6 cervical segments removed from human cadavers of both genders were assessed and divided into five groups of 10-year age intervals, from 21 years old. TVP and intervertebral disc thickness evaluation was made by means of histomorphometry of histological slides stained with hematoxylin and eosyn. Lower C4 TVP, upper C5 TVP, and upper C6 TVP de were compared between each other and to the interposed intervertebral disc thickness between relevant TVP. Results: The thickness of terminal vertebral plates adjacent to the same ID did not show statistic differences. However, the comparison of upper and lower vertebral plates thickness on the same cervical vertebra (C5), showed statistical difference on all age groups studied. We found a statistical correlation coefficient above 80% between terminal vertebral plate and adjacent intervertebral disc, with a proportional thickness reduction of both structures on the different cervical levels studied, and also on the different age groups assessed. Conclusion: Terminal vertebral plate shows a morphologic correlation with the intervertebral disc next to it, and does not show correlation with the terminal vertebral plate on the same vertebra. PMID:26998448

  3. A simple sub-nanosecond ultraviolet light pulse generator with high repetition rate and peak power.

    Science.gov (United States)

    Binh, P H; Trong, V D; Renucci, P; Marie, X

    2013-08-01

    We present a simple ultraviolet sub-nanosecond pulse generator using commercial ultraviolet light-emitting diodes with peak emission wavelengths of 290 nm, 318 nm, 338 nm, and 405 nm. The generator is based on step recovery diode, short-circuited transmission line, and current-shaping circuit. The narrowest pulses achieved have 630 ps full width at half maximum at repetition rate of 80 MHz. Optical pulse power in the range of several hundreds of microwatts depends on the applied bias voltage. The bias voltage dependences of the output optical pulse width and peak power are analysed and discussed. Compared to commercial UV sub-nanosecond generators, the proposed generator can produce much higher pulse repetition rate and peak power.

  4. Over 0.5 MW green laser from sub-nanosecond giant pulsed microchip laser

    Science.gov (United States)

    Zheng, Lihe; Taira, Takunori

    2016-03-01

    A sub-nanosecond green laser with laser head sized 35 × 35 × 35 mm3 was developed from a giant pulsed microchip laser for laser processing on organic superconducting transistor with a flexible substrate. A composite monolithic Y3Al5O12 (YAG) /Nd:YAG/Cr4+:YAG/YAG crystal was designed for generating giant pulsed 1064 nm laser. A fibercoupled 30 W laser diode centered at 808 nm was used with pump pulse duration of 245 μs. The 532 nm green laser was obtained from a LiB3O5 (LBO) crystal with output energy of 150 μJ and pulse duration of 268 ps. The sub-nanosecond green laser is interesting for 2-D ablation patterns.

  5. Gas Breakdown in the Sub-Nanosecond Regime with Voltages Below 15 KV

    Science.gov (United States)

    2013-06-01

    here gas breakdown during nanosecond pulses occurs mainly as corona discharges on wire antennas, and represents an unwanted effect - General...switching for pulsed power applications Published data [2,3,4,5] for subnanosecond breakdown are mainly related to discharges in gases with...pressures at or above one atmosphere , or for liquids, and for quasi- homogeneous electric fields which are at least on the order of several 100 kV/cm. For

  6. Mechanism of formation of subnanosecond current front in high-voltage pulse open discharge

    Science.gov (United States)

    Schweigert, I. V.; Alexandrov, A. L.; Zakrevsky, Dm. E.; Bokhan, P. A.

    2014-11-01

    The mechanism of subnanosecond current front rise observed previously in the experiment in high-voltage pulse open discharge in helium is studied in kinetic particle-in-cell simulations. The Boltzmann equations for electrons, ions, and fast atoms are solved self-consistently with the Poisson equations for the electrical potential. The partial contributions to the secondary electron emission from the ions, fast atoms, photons, and electrons, bombarding the electrode, are calculated. In simulations, as in the experiment, the discharge glows between two symmetrical cathodes and the anode grid in the midplane at P =6 Torr and the applied voltage of 20 kV. The electron avalanche development is considered for two experimental situations during the last stage of breakdown: (i) with constant voltage and (ii) with decreasing voltage. For case (i), the subnanosecond current front rise is set by photons from the collisional excitation transfer reactions. For the case (ii), the energetic electrons swamp the cathode during voltage drop and provide the secondary electron emission for the subnanosecond current rise, observed in the experiment.

  7. A Single Pulse Sub-Nanosecond Proton RFQ

    Energy Technology Data Exchange (ETDEWEB)

    Hamm, R W; Pearce-Percy, H; Pearson, D; Rougieri, M; Weir, J; Zografos, A; Guethlein, G; Hawkins, S; Falabella, S; Poole, B; Blackfield, D

    2011-03-29

    A Radio Frequency Quadrupole (RFQ) linac system has been developed to provide a single pulse of 2 MeV protons with a beam pulse width of {approx}300 ps and a charge of 30 pC, either for injection into a pulsed Dielectric Wall Accelerator or for bombardment of a target to produce a fast neutron pulse. The 1.2 m long RFQ structure operates at 425 MHz and bunches and accelerates a single 2.35 ns beam pulse injected into it at 35 keV using a parallel plate deflector placed directly in front of the RFQ entrance. The input acceptance properties of the RFQ allow a simple dc bias voltage on the plates to block acceleration of the unwanted beam, with a short rf voltage pulse applied to null the deflection field for the ions within the 8 mm 'kicker' plate length. The use of the RFQ as the accelerating structure allows one to efficiently produce a large charge in a single sub-ns bunch. In addition, the kicker can also be used without the dc bias voltage to produce a 'notch' in the normal RFQ output beam for synchrotron injection.

  8. Numerical Study Of The Heat Transfer Phenomenon Of A Rectangular Plate Including Void, Notch Using Finite Difference Technique

    Science.gov (United States)

    Deb Nath, S. K.; Peyada, N. K.

    2015-12-01

    In the present study, we have developed a code using Matlab software for solving a rectangular aluminum plate having void, notch, at different boundary conditions discretizing a two dimensional (2D) heat conduction equation by the finite difference technique. We have solved a 2D mixed boundary heat conduction problem analytically using Fourier integrals (Deb Nath et al., 2006; 2007; 2007; Deb Nath and Ahmed, 2008; Deb Nath, 2008; Deb Nath and Afsar, 2009; Deb Nath and Ahmed, 2009; 2009; Deb Nath et al., 2010; Deb Nath, 2013) and the same problem is also solved using the present code developed by the finite difference technique (Ahmed et al., 2005; Deb Nath, 2002; Deb Nath et al., 2008; Ahmed and Deb Nath, 2009; Deb Nath et al., 2011; Mohiuddin et al., 2012). To verify the soundness of the present heat conduction code results using the finite difference method, the distribution of temperature at some sections of a 2D heated plate obtained by the analytical method is compared with those of the plate obtained by the present finite difference method. Interpolation technique is used as an example when the boundary of the plate does not pass through the discretized grid points of the plate. Sometimes hot and cold fluids are passed through rectangular channels in industries and many types of technical equipment. The distribution of temperature of plates including notches, slots with different temperature boundary conditions are studied. Transient heat transfer in several pure metallic plates is also studied to find out the required time to reach equilibrium temperature. So, this study will help find design parameters of such structures.

  9. Numerical Study Of The Heat Transfer Phenomenon Of A Rectangular Plate Including Void, Notch Using Finite Difference Technique

    Directory of Open Access Journals (Sweden)

    Deb Nath S.K.

    2015-12-01

    Full Text Available In the present study, we have developed a code using Matlab software for solving a rectangular aluminum plate having void, notch, at different boundary conditions discretizing a two dimensional (2D heat conduction equation by the finite difference technique. We have solved a 2D mixed boundary heat conduction problem analytically using Fourier integrals (Deb Nath et al., 2006; 2007; 2007; Deb Nath and Ahmed, 2008; Deb Nath, 2008; Deb Nath and Afsar, 2009; Deb Nath and Ahmed, 2009; 2009; Deb Nath et al., 2010; Deb Nath, 2013 and the same problem is also solved using the present code developed by the finite difference technique (Ahmed et al., 2005; Deb Nath, 2002; Deb Nath et al., 2008; Ahmed and Deb Nath, 2009; Deb Nath et al., 2011; Mohiuddin et al., 2012. To verify the soundness of the present heat conduction code results using the finite difference method, the distribution of temperature at some sections of a 2D heated plate obtained by the analytical method is compared with those of the plate obtained by the present finite difference method. Interpolation technique is used as an example when the boundary of the plate does not pass through the discretized grid points of the plate. Sometimes hot and cold fluids are passed through rectangular channels in industries and many types of technical equipment. The distribution of temperature of plates including notches, slots with different temperature boundary conditions are studied. Transient heat transfer in several pure metallic plates is also studied to find out the required time to reach equilibrium temperature. So, this study will help find design parameters of such structures.

  10. Generalized equations of finite difference method in the problems of dynamic load calculation for thin bending plates

    Directory of Open Access Journals (Sweden)

    Gabbasov Radek Fatykhovich

    Full Text Available Bending plate is widely used in the construction of large-span structures. Its advantage is light weight, industrial production, low cost and easy installation. Implementing the algorithm for calculating bending plates in engineering practice is an important issue of the construction science. The generalized equations of finite difference method is a new trend in the calculation of building construction. FDM with generalized equation provides additional options for an engineer along with other methods (FEM. In the article the algorithm for dynamic calculation of thin bending plates basing on FDM was developed. The computer programs for dynamic calculation were created on the basis of the algorithm. The authors come to the conclusion that the more simple equations of FDM can be used in case of solving the impulse load problems in dynamic load calculation of thin bending plate.

  11. INTEGRAL EQUATION METHOD'S APPLICATION IN HOLE-EDGE STRESS OF COMPOSITE MATERIAL PLATE WITH DIFFERENT SHAPED HOLES

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    The strength of composite plate with different hole-shapes is always one of the most important but complicated issues in the application of the composite material. The holes will lead to mutations and discontinuity to the structure. So the hole-edge stress concentration is always a serious phenomenon. And the phenomenon makes the structure strength decrease very quickly to form dangerous weak points. Most partial damage begins from these weak points. According to the complex variable functions theory, the accurate boundary condition of composite plate with different hole-shapes is founded by conformal mapping method to settle the boundary condition problem of complex hole-shapes. Composite plate with commonly hole-shapes in engineering is studied by several complex variable stress function. The boundary integral equations are founded based on exact boundary conditions. Then the exact hole-edge stress analytic solution of composite plate with rectangle holes and wing manholes is resolved. Both of offset axis loadings and its influences on the stress concentration coefficient of the hole-edge are discussed. And comparisons of different loads along various offset axis on the hole-edge stress distribution of orthotropic plate with rectangle hole or wing manhole are made. It can be concluded that hole-edge with continuous variable curvatures might help to decrease the stress concentration coefficient; and smaller angle of outer load and fiber can decrease the stress peak value.

  12. Biomechanical Analysis of Implanted Clavicle Hook Plates With Different Implant Depths and Materials in the Acromioclavicular Joint: A Finite Element Analysis Study.

    Science.gov (United States)

    Lee, Cheng-Hung; Shih, Cheng-Min; Huang, Kui-Chou; Chen, Kun-Hui; Hung, Li-Kun; Su, Kuo-Chih

    2016-11-01

    Clinical implantation of clavicle hook plates is often used as a treatment for acromioclavicular joint dislocation. However, it is not uncommon to find patients that have developed acromion osteolysis or had peri-implant fracture after hook plate fixation. With the aim of preventing complications or fixation failure caused by implantation of inappropriate clavicle hook plates, the present study investigated the biomechanics of clavicle hook plates made of different materials and with different hook depths in treating acromioclavicular joint dislocation, using finite element analysis (FEA). This study established four parts using computer models: the clavicle, acromion, clavicle hook plate, and screws, and these established models were used for FEA. Moreover, implantations of clavicle hook plates made of different materials (stainless steel and titanium alloy) and with different depths (12, 15, and 18 mm) in patients with acromioclavicular joint dislocation were simulated in the biomechanical analysis. The results indicate that deeper implantation of the clavicle hook plate reduces stress on the clavicle, and also reduces the force applied to the acromion by the clavicle hook plate. Even though a clavicle hook plate made of titanium alloy (a material with a lower Young's modulus) reduces the force applied to the acromion by the clavicle hook plate, slightly higher stress on the clavicle may occur. The results obtained in this study provide a better reference for orthopedic surgeons in choosing different clavicle hook plates for surgery. Copyright © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  13. High-resolution SIT TV tube for subnanosecond image shuttering

    Science.gov (United States)

    Yates, G. J.; Vine, B. H.; Aeby, I.; Dunbar, D. L.; King, N. S. P.; Jaramillo, S. A.; Thayer, N. N.; Noel, B. W.

    1984-09-01

    A new ultrafast high-resolution image shutter tube with reasonable gain and shuttering efficiency has been designed and tested. The design uses a grid-gated silicon-intensified-target (SIT) image section and a high-speed focus projection and scan (FPS) vidicon read-out section in one envelope to eliminate resolution losses from external coupling. The design features low-gate-interface capacity, a high-conductivity shutter grid, and a segmented low-resistivity photocathode for optimum gating speed. Optical gate widths as short as 400 ps + or - 100 ps for full shuttering of the 25-mm-diam input window with spatial resolution as high as 15 1p/mm have been measured. Some design criteria, most of the electrical and optical performance data for several variations in the basic design, and a comparison (of several key response functions) with similarly tested 18- and 25-mm-diam proximity-focused microchannel-plate (MCP) image intensifier tubes (MCPTs) are included.

  14. Pulsed laser deposition of metal films and nanoparticles in vacuum using subnanosecond laser pulses.

    Science.gov (United States)

    Ganeev, R A; Chakravarty, U; Naik, P A; Srivastava, H; Mukherjee, C; Tiwari, M K; Nandedkar, R V; Gupta, P D

    2007-03-10

    A study of silver, chromium, stainless-steel, and indium thin films prepared by subnanosecond laser deposition in vacuum is reported. We compare the laser ablation in vacuum at the weak- and tight-focusing conditions of a Ti:sapphire laser beam and analyze the nanoparticles synthesized in the latter case using absorption spectroscopy, x-ray fluorescence, atomic force microscopy, and scanning electron microscopy. Our results show that the nanoparticle formation can be accomplished using long laser pulses under tight-focusing conditions.

  15. Subnanosecond-laser-induced periodic surface structures on prescratched silicon substrate

    Science.gov (United States)

    Hongo, Motoharu; Matsuo, Shigeki

    2016-06-01

    Laser-induced periodic surface structures (LIPSS) were fabricated on a prescratched silicon surface by irradiation with subnanosecond laser pulses. Low-spatial-frequency LIPSS (LSFL) were observed in the central and peripheral regions; both had a period Λ close to the laser wavelength λ, and the wavevector orientation was parallel to the electric field of the laser beam. The LSFL in the peripheral region seemed to be growing, that is, expanding in length with increasing number of pulses, into the outer regions. In addition, high-spatial-frequency LIPSS, Λ ≲ λ /2, were found along the scratches, and their wavevector orientation was parallel to the scratches.

  16. Dynamic subnanosecond time-of-flight detection for ultra-precise diffusion monitoring and optimization of biomarker preservation

    Science.gov (United States)

    Bauer, Daniel R.; Stevens, Benjamin; Taft, Jefferson; Chafin, David; Petre, Vinnie; Theiss, Abbey P.; Otter, Michael

    2014-03-01

    Recently, it has been demonstrated that the preservation of cancer biomarkers, such as phosphorylated protein epitopes, in formalin-fixed paraffin-embedded tissue is highly dependent on the localized concentration of the crosslinking agent. This study details a real-time diffusion monitoring system based on the acoustic time-of-flight (TOF) between pairs of 4 MHz focused transducers. Diffusion affects TOF because of the distinct acoustic velocities of formalin and interstitial fluid. Tissue is placed between the transducers and vertically translated to obtain TOF values at multiple locations with a spatial resolution of approximately 1 mm. Imaging is repeated for several hours until osmotic equilibrium is reached. A post-processing technique, analogous to digital acoustic interferometry, enables detection of subnanosecond TOF differences. Reference subtraction is used to compensate for environmental effects. Diffusion measurements with TOF monitoring ex vivo human tonsil tissue are well-correlated with a single exponential curve (R2>0.98) with a magnitude of up to 50 ns, depending on the tissue size (2-6 mm). The average exponential decay constant of 2 and 6 mm diameter samples are 20 and 315 minutes, respectively, although times varied significantly throughout the tissue (σmax=174 min). This technique can precisely monitor diffusion progression and could be used to mitigate effects from tissue heterogeneity and intersample variability, enabling improved preservation of cancer biomarkers distinctly sensitive to degradation during preanalytical tissue processing.

  17. Notched Strength of Woven Fabric Kenaf Composite Plates with Different Stacking Sequences and Hole Sizes

    Directory of Open Access Journals (Sweden)

    Hans Romayne Anders

    2016-01-01

    Full Text Available Advantages of using kenaf fibres over synthetic fibres in composites manufacturing are relatively cheap, less abrasive and hazardous during handling, and renewable materials. Current work investigates parametric effects on notched strength of woven fabric kenaf polymer composites plates with variation of lay-up types, notch sizes and plate thickness. Testing coupons are prepared using hand lay-up technique and circular notch were drilled prior to mechanical testing. Stress concentration at the notch edge promotes micro-damage event as tensile loading was applied leading to crack initiation and propagations across the plate width. It is suggested that woven fabric kenaf polymer composites are potentially used in low and medium load bearing applications.

  18. Are there any differences in various polyaxial locking systems? A mechanical study of different locking screws in multidirectional angular stable distal radius plates.

    Science.gov (United States)

    Mehling, Isabella; Scheifl, Rebekka; Mehler, Dorothea; Klitscher, Daniela; Hely, Hans; Rommens, Pol M

    2013-04-01

    Numerous angular stable plates for the distal radius exist, and technically based comparisons of the polyaxial locking interfaces are lacking. The aim of this mechanical study was to investigate three different locking interfaces of angular stable volar plates by cantilever bending: VA-LCP Two-Column Distal Radius Plates 2.4 mm (Synthes® GmbH, Oberdorf, Switzerland), IXOS® P4 (Martin, Tuttlingen, Germany) and VariAX™ (Stryker®, Duisburg, Germany). We assessed the strength of 0°, 5°, 10° and 15° screw locking angles and tested the bending strength from 10° to 5° angles by cyclic loading until breakage. The final setup repeated the above assessments by inclusion of four locking screws. The single screw-plate interfaces of the VA-LCP showed the highest bending moment at an angle of 0° and 5°, the IXOS® P4 at an angle of 10° and 15° and the VariAX™ when changing the insertion angle from 10° into 5°. The strength of polyaxial locking interfaces and mechanism of failure proved to be different among the examined plates.

  19. 2-D Finite Difference Modeling of the D'' Structure Beneath the Eastern Cocos Plate: Part I

    Science.gov (United States)

    Helmberger, D. V.; Song, T. A.; Sun, D.

    2005-12-01

    The discovery of phase transition from Perovskite (Pv) to Post-Perovskite (PPv) at depth nears the lowermost mantle has revealed a new view of the earth's D'' layer (Oganov et al. 2004; Murakami et al. 2004). Hernlund et al. (2004) recently pusposed that, depending on the geotherm at the core-mantle boundary (CMB), a double-crossing of the phase boundary by the geotherm at two different depths may also occur. To explore these new findings, we adopt 2-D finite difference scheme (Helmberger and Vidale, 1988) to model wave propagation in rapidly varying structure. We collect broadband waveform data recorded by several Passcal experiments, such as La Ristra transect and CDROM transect in the southwest US to constrain the lateral variations in D'' structure. These data provide fairly dense sampling (~ 20 km) in the lowermost mantle beneath the eastern Cocos plate. Since the source-receiver paths are mostly in the same azimuth, we make 2-D cross-sections from global tomography model (Grand, 2002) and compute finite difference synthetics. We modify the lowermost mantle below 2500 km with constraints from transverse-component waveform data at epicentral distances of 70-82 degrees in the time window between S and ScS, essentially foward modeling waveforms. Assuming a velocity jump of 3 % at D'', our preferred model shows that the D'' topography deepens from the north to the south by about 120 km over a lateral distance of 300 km. Such large topography jumps have been proposed by Thomas et al. (2004) using data recorded by TriNet. In addition, there is a negative velocity jump (-3 %) 100 km above the CMB in the south. This simple model compare favorably with results from a study by Sun, Song and Helmberger (2005), who follow Sidorin et al. (1999) approach and produce a thermodynamically consistent velocity model with Pv-PPv phase boundary. It appears that much of this complexity exists in Grand's tomographic maps with rapid variation in velocities just above the D''. We also

  20. Uncertainty contributions due to different measurement strategies applied to optomechanical hole plate

    DEFF Research Database (Denmark)

    Morace, Renate Erica; Hansen, Hans Nørgaard; De Chiffre, Leonardo

    2003-01-01

    The work described in this paper deals with influence parameters in optical measurements, with particular respect to the choice of measurement strategy, which strongly affects the results of measurement. In this investigation, an optomechanical hole plate developed by DTU was measured with an opt...

  1. Growth plate cartilage shows different strain patterns in response to static versus dynamic mechanical modulation.

    Science.gov (United States)

    Kaviani, Rosa; Londono, Irene; Parent, Stefan; Moldovan, Florina; Villemure, Isabelle

    2016-08-01

    Longitudinal growth of long bones and vertebrae occurs in growth plate cartilage. This process is partly regulated by mechanical forces, which are one of the underlying reasons for progression of growth deformities such as idiopathic adolescent scoliosis and early-onset scoliosis. This concept of mechanical modulation of bone growth is also exploited in the development of fusionless treatments of these deformities. However, the optimal loading condition for the mechanical modulation of growth plate remains to be identified. The objective of this study was to evaluate the effects of in vitro static versus dynamic modulation and of dynamic loading parameters, such as frequency and amplitude, on the mechanical responses and histomorphology of growth plate explants. Growth plate explants from distal ulnae of 4-week-old swines were extracted and randomly distributed among six experimental groups: baseline ([Formula: see text]), control ([Formula: see text]), static ([Formula: see text]) and dynamic ([Formula: see text]). For static and dynamic groups, mechanical modulation was performed in vitro using an Indexed CartiGen bioreactor. A stress relaxation test combined with confocal microscopy and digital image correlation was used to characterize the mechanical responses of each explant in terms of peak stress, equilibrium stress, equilibrium modulus of elasticity and strain pattern. Histomorphometrical measurements were performed on toluidine blue tissue sections using a semi-automatic custom-developed MATLAB toolbox. Results suggest that compared to dynamic modulation, static modulation changes the strain pattern of the tissue and thus is more detrimental for tissue biomechanics, while the histomorphological parameters are not affected by mechanical modulation. Also, under dynamic modulation, changing the frequency or amplitude does not affect the biomechanical response of the tissue. Results of this study will be useful in finding optimal and non-damaging parameters

  2. Systematic investigation of different formulations for drug delivery through the human nail plate "in vitro"

    OpenAIRE

    Vejnoviċ, Ivana

    2010-01-01

    Human nails do not have only protective and decorative role, but can also be considered as an alternative pathway for drug delivery, especially in nail diseases such as onychomycosis or psoriasis. These nail diseases are widely spread in the population, particularly among elderly and immunocompromised patients. Oral therapies are accompanied by systemic side effects and drug interactions, while topical therapies are limited by the low permeation rate through the nail plate. For the successful...

  3. Systematic investigation of different formulations for drug delivery through the human nail plate "in vitro"

    OpenAIRE

    Vejnoviċ, Ivana

    2010-01-01

    Human nails do not have only protective and decorative role, but can also be considered as an alternative pathway for drug delivery, especially in nail diseases such as onychomycosis or psoriasis. These nail diseases are widely spread in the population, particularly among elderly and immunocompromised patients. Oral therapies are accompanied by systemic side effects and drug interactions, while topical therapies are limited by the low permeation rate through the nail plate. For the successful...

  4. Investigation of different formulations for drug delivery through the nail plate.

    Science.gov (United States)

    Vejnovic, Ivana; Simmler, Linda; Betz, Gabriele

    2010-02-15

    Topical therapies for nail diseases are limited by keratinized cells in the human nail plate. An optimal permeation enhancer would not only improve drug delivery through the nail plate, but would also open new possibilities for treating neighboring target sites if systemic circulation is reached. The aim of the present work was to identify permeation enhancers and to improve the understanding of physicochemical parameters that influence drug permeation. Caffeine served as the model drug, and formulations were prepared in water and 20% (v/v) ethanol/water solutions. Tested enhancers were urea, dimethyl sulfoxide (DMSO), methanol, N-acetyl-L-cysteine (NAC), docusate sodium salt (DSS), boric acid, and fungal proteins, such as hydrophobins. Permeability studies employed cadaver nails in modified Franz-type diffusion cells. The permeability coefficient of caffeine in ethanol/water was determined to be 1.56 E-08 cm/s and was improved to 2.27 E-08 cm/s by the addition of NAC. Formulations containing either methanol or DMSO showed the highest permeability coefficients in the range of 5-7.5 E-08 cm/s. Enhancers could be classified according to their permeation enhancement: methanol>class II hydrophobins>DMSO>followed by class I hydrophobins and urea. Ethanol at a concentration of 20% (v/v) in water did not influence swelling of nail samples. Hydrophobins are suggested to be efficient in drug delivery through the nail plate. Copyright 2009 Elsevier B.V. All rights reserved.

  5. Cavitation erosion of silver plated coating at different temperatures and pressures

    Energy Technology Data Exchange (ETDEWEB)

    Hattori, Shuji; Motoi, Yoshihiro [Graduate School of Engineering, University of Fukui, 3-9-1 Bunkyo, Fuku-shi, Fukui 910-8507 (Japan); Kikuta, Kengo; Tomaru, Hiroshi [IHI Corperation, TOYOSU IHI BUILDING, 1-1, Toyosu 3-chome, Koto-ku, Tokyo 1358710 (Japan)

    2014-04-11

    Cavitation often occurs in inducer pumps used for space rockets. Silver plated coating on the inducer liner faces the damage of cavitation. Therefore, it is important to study about the cavitation erosion resistance for silver plated coating at several operating conditions in the inducer pumps. In this study, the cavitation erosion tests were carried for silver plated coating in deionized water and ethanol at several liquid temperatures (273K–400K) and pressures (0.10MPa–0.48MPa). The mass loss rate is evaluated in terms of thermodynamic parameter Σ proposed by Brennen [9], suppression pressure p–p{sub v} (p{sub v}: saturated vapor pressure) and acoustic impedance ρc (ρ: density and c: sound speed). Cavitation bubble behaviors depending on the thermodynamic effect and the liquid type were observed by high speed video camera. The mass loss rate is formulated by thermodynamic parameter Σ, suppression pressure p–p{sub v} and acoustic impedance ρc.

  6. Stress Analysis and Optimization of a Piaggio Ape Clutch Plate with different Friction Materials

    Directory of Open Access Journals (Sweden)

    B.Sreedher

    2014-11-01

    Full Text Available clutch plate is one of the important part in the power transmission systems. Good design of clutch provides better engine performance. Clutch is device which is used to engage or disengage of gears and it transfers the rotary motion of one shaft to the other shaft when desired. In automobiles friction clutches are widely used in power transmission applications. To transmit maximum torque in friction clutches selection of the friction material is one of the important tasks. In this thesis a model of Piaggio Ape clutch plate has been generated in Pro-E Cre0-5 and then imported in ANSYS for power transmission applications. We have conducted structural analysis by varying the friction surfaces material and keeping base material aluminium same. By seeing the results, Comparison is done for both materials to validate better lining material for Piaggio Ape clutch plate by doing analysis on clutch with help of ANSYS software for find out which material is best for the lining of friction surfaces.

  7. Changes in Properties of Dielectric Barrier Discharge Plasma Jets for Different Gases and for Insulating and Conducting Transfer Plates

    Science.gov (United States)

    do Nascimento, Fellype; Moshkalev, Stanislav; Machida, Munemasa

    2017-03-01

    Dielectric barrier discharge (DBD) plasma jets have been studied extensively in recent years because of its wide range of applications. DBD plasmas can be produced using many different gases and can be applied to a broad variety of surfaces and substrates. This work provides comparisons of DBD plasmas generated using argon (Ar), helium (He), and nitrogen (N2), as well as their mixtures with water vapor in order to know how some plasma properties are affected by the use of different gases. All plasmas were studied in two different conditions: using a transfer plate made of a conductive material and using a transfer plate made of an insulating one. It was observed that the process of Penning ionization of nitrogen molecules by direct collisions with metastable atoms and molecules is evident and significant only in plasmas that use He as the working gas, which means that He atoms in metastable states have greater ability to transfer energy to molecules of nitrogen in the plasma. The collisions of metastable He with N2 molecules determine the vibrational temperature (T vib) values in He plasmas, while in Ar and N2 plasmas, the T vib values are determined mainly by collisions of electrons with N2 molecules. It was noticed that the use of an insulating or a conducting transfer plate as the sample holder affects the results of adhesion between poly(dimethylsiloxane) samples, and it is mainly due to the differences in the plasma power, with a higher plasma power leading to better adhesion.

  8. Determining the values of second-order surface nonlinearities by measurements with wave plates of different retardations.

    Science.gov (United States)

    Valev, Ventsislav K; Foerier, Stijn; Verbiest, Thierry

    2009-06-01

    We measured the second harmonic generation response of a thin film consisting of chiral molecules with four wave plates having different retardation coefficients. By means of the fitting procedure described in a previously reported formalism, we demonstrated that a single set of tensor components of second order surface nonlinearities fits all the data. Our results provide clear experimental evidence for the validity of this method, which can find applications in the studies of chiral structures and achiral anisotropic materials.

  9. Effects of different friction stir welding conditions on the microstructure and mechanical properties of copper plates

    Science.gov (United States)

    Nia, Ali Alavi; Shirazi, Ali

    2016-07-01

    Friction stir welding is a new and innovative welding method used to fuse materials. In this welding method, the heat generated by friction and plastic flow causes significant changes in the microstructure of the material, which leads to local changes in the mechanical properties of the weld. In this study, the effects of various welding parameters such as the rotational and traverse speeds of the tool on the microstructural and mechanical properties of copper plates were investigated; additionally, Charpy tests were performed on copper plates for the first time. Also, the effect of the number of welding passes on the aforementioned properties has not been investigated in previous studies. The results indicated that better welds with superior properties are produced when less heat is transferred to the workpiece during the welding process. It was also found that although the properties of the stir zone improved with an increasing number of weld passes, the properties of its weakest zone, the heat-affected zone, deteriorated.

  10. Subnanosecond microwave-assisted magnetization switching in a circularly polarized microwave magnetic field

    Science.gov (United States)

    Suto, Hirofumi; Kanao, Taro; Nagasawa, Tazumi; Kudo, Kiwamu; Mizushima, Koichi; Sato, Rie

    2017-06-01

    We study microwave-assisted magnetization switching (MAS) of a perpendicularly magnetized nanomagnet with a diameter of 50 nm in a circularly polarized microwave magnetic field. The MAS effect appears when the rotation direction of the microwave field matches that of the ferromagnetic resonance excitation, and a large switching field decrease from 7.1 kOe to 1.5 kOe is demonstrated. In comparison with a linearly polarized microwave magnetic field, the circularly polarized microwave field induces the same MAS effect at half the microwave field amplitude, thereby showing its efficiency. We also examine MAS in the subnanosecond region and show that the magnetization switching can be induced by a microwave field with the duration of 0.2 ns.

  11. Tunable CO2 laser system with subnanosecond-pulse-train output

    Science.gov (United States)

    Kimura, W. D.

    2017-02-01

    A CO2 laser system has been demonstrated that generates a train of subnanosecond pulses tunable over the P and R branches of the CO2 laser spectrum at 9-11 μm. It utilizes optical free induction decay to generate a single 100-ps laser pulse from a tunable transverse-excited-atmospheric CO2 laser. This laser pulse is injection-seeded into a high-pressure CO2 oscillator whose output consists of a train of amplified 100-ps pulses with maximum pulse energy of 30 mJ, corresponding to a peak power of 300 MW. The 100-ps, tunable, infrared laser pulses are needed for a new technique to remotely detect atmospheric gaseous molecules, which relies on the train of CO2 laser pulses selectively exciting the target molecules whose presence is then revealed using a separate terahertz probe beam.

  12. Sub-nanosecond machine timing and frequency distribution via serial data links

    CERN Document Server

    Rohlev, A; Serrano, J; Cattin, M; Settler, M

    2008-01-01

    FERMI@ELETTRA is a 4th generation light source under construction at Sincrotrone Trieste. It will be operated as a seeded FEL driven by a warm S-band Linac which places very stringent specifications on control of the amplitude and phase of the RF stations. The local clock generation and distribution system at each station will not be based on the phase reference distribution but rather on a separate frequency reference distribution which has significantly less stringent phase stability requirements. This frequency reference will be embedded in the serial data link to each station and has the further advantage of being able to broadcast synchronous machine timing signals with sub-nanosecond temporal accuracy. The phase and amplitude of the phase reference line is measured for each pulse and used to calibrate the other measurements. This paper describes the architecture used to distribute the frequency reference along with the precision machine timing and clocking signals.

  13. Sub-nanosecond, time-resolved, broadband infrared spectroscopy using synchrotron radiation

    CERN Document Server

    Lobo, R; Reitze, D H; Tanner, D B; Carr, G L

    2001-01-01

    A facility for sub-nanosecond time-resolved (pump-probe) infrared spectroscopy has been developed at the National Synchrotron Light Source of Brookhaven National Laboratory. A mode-locked Ti:sapphire laser produces 2 ps duration, tunable near-IR pump pulses synchronized to probe pulses from a synchrotron storage ring. The facility is unique on account of the broadband infrared from the synchrotron, which allows the entire spectral range from 2 cm-1 (0.25 meV) to 20,000 cm-1 (2.5 eV) to be probed. A temporal resolution of 200 ps, limited by the infrared synchrotron-pulse duration, is achieved. A maximum time delay of 170 ns is available without gating the infrared detector. To illustrate the performance of the facility, a measurement of electron-hole recombination dynamics for an HgCdTe semiconductor film in the far- and mid infrared range is presented.

  14. Wetting Behavior of Molten AZ61 Magnesium Alloy on Two Different Steel Plates Under the Cold Metal Transfer Condition

    Directory of Open Access Journals (Sweden)

    ZENG Cheng-zong

    2017-04-01

    Full Text Available The wetting behavior and interfacial microstructures of molten magnesium AZ61 alloy on the surface of two different Q235 and galvanized steel plates under the condition of cold metal transfer were investigated by using dynamic sessile drop method. The results show that the wetting behavior is closely related to the wire feed speed. Al-Fe intermetallic layer was observed whether the substrate is Q235 steel or galvanized steel, and the formation of Al-Fe intermetallic layer should satisfy the thermodynamic condition of such Mg-Al/Fe system. The wettability of molten AZ61 magnesium alloy is improved with the increase of wire feed speed whether on Q235 steel surface or on galvanized steel surface, good wettability on Q235 steel surface is due to severe interface reaction when wire feed speed increases, good wettability on galvanized steel surface is attributed to the aggravating zinc volatilization. When the wire feed speed is ≤10.5m·min-1, the wettability of Mg alloy on Q235 steel plate is better than on galvanized steel plate. However, Zn vapor will result in instability for metal transfer process.

  15. Processless offset printing plates

    Directory of Open Access Journals (Sweden)

    Sanja Mahović Poljaček

    2015-06-01

    Full Text Available With the implementation of platesetters in the offset printing plate making process, imaging of the printing plate became more stable and ensured increase of the printing plate quality. But as the chemical processing of the printing plates still highly influences the plate making process and the graphic reproduction workflow, development of printing plates that do not require chemical processing for offset printing technique has been one of the top interests in graphic technology in the last few years. The main reason for that came from the user experience, where majority of the problems with plate making process could be connected with the chemical processing of the printing plate. Furthermore, increased environmental standards lead to reducing of the chemicals used in the industrial processes. Considering these facts, different types of offset printing plates have been introduced to the market today. This paper presents some of the processless printing plates.

  16. A Model for Predicting the Yield Strength Difference between Pipe and Plate of Low-Carbon Microalloyed Steel

    Science.gov (United States)

    Zhang, Wenlong; Ding, Dongyan; Gu, Mingyuan

    2012-12-01

    A combination of finite-element calculation and tension-compression tests was employed to predict the yield strength difference between the pipe and plate of low-carbon microalloyed steel (LCMS) in the production of high-frequency straight bead welding pipes (HFSBWPs). The deformation process was divided into bending, flattening, and tension deformations. The bending and flattening deformations were simulated using a finite-element method in order to obtain circumferential strains at pipe wall positions along the wall thickness. These strains were the transition strains in the subsequent tension-compression-tension and compression-tension tests. The yield stresses (0.5 pct proof stresses) at the pipe wall positions were derived from the obtained stress-strain curves. The average of the obtained yield stresses was taken as the predicted yield strength of the pipes. It is found that the difference between the latter and the strength of the original steel plates is a result of the combined action of the Bauschinger effect and strain hardening caused by bending and reverse bending deformations. It is strongly dependent on the ratio of pipe wall thickness to pipe outer diameter ( T/D ratio). At low T/D ratios, the Bauschinger effect was dominant, resulting in a decreased yield strength. Strain hardening due to work hardening was dominant at higher T/D ratios, resulting in an increased yield strength. The increase in yield strength was greater at the inner pipe walls than at outer ones, indicating that strain hardening is stronger at inner pipe walls. The yield strength differences predicted with the presented approach are comparable with the values obtained from industrial productions of HFSBWPs, indicating that this approach can be used to predict the yield strength difference between pipe and plate of LCMS.

  17. A comparison of different NDE signal processing techniques based on waveform entropies applied to long fiber-graphite/epoxy-plates

    Science.gov (United States)

    Larche, Michael; Prowant, Mathew; Bruillard, Paul; Hagge, Tobias; Fifield, Leonard S.; Hughes, Michael; Sun, Xin

    2017-04-01

    This study compares different approaches for imaging the internal architecture of graphite/epoxy composites using backscattered ultrasound. Two cases are studied. In the first, near-surface defects in a thin graphite/epoxy plates are imaged. The backscattered waveforms were used to produce peak-to-peak, logarithm of signal energy, as well as entropy images of different types. All of the entropy images exhibit better border delineation and defect contrast than either the peak-to-peak or the logarithm of signal energy. The best results are obtained using the joint entropy of the backscattered waveforms with a reference function. Two different references are examined. The first is a reflection of the insonifying pulse from a stainless steel reflector. The second is an approximate optimum obtained from an iterative parametric search. The joint entropy images produced using this reference exhibit three times the contrast obtained in previous studies. These plates were later destructively analyzed to determine size and location of near-surface defects and the results are found to agree with the defect location and shape as indicated by the entropy images. In the second study, images of long carbon fibers (50% by weight) in polypropylene thermoplastic were obtained as a first step toward ultrasonic determination of the distributions of fiber position and orientation.

  18. A Comparison of Different NDE Signal Processing Techniques Based on Waveform Entropies Applied to Long Fiber Graphite/Epoxy Plates

    Energy Technology Data Exchange (ETDEWEB)

    Larche, Michael R.; Prowant, Matthew S.; Bruillard, Paul J.; Hagge, Tobias J.; Fifield, Leonard S.; Hughes, Michael S.; Sun, Xin

    2017-04-19

    This study compares different approaches for imaging the internal architecture of graphite/epoxy composites using backscattered ultrasound. Two cases are studied. In the first, near-surface defects in a thin graphite/epoxy plates are imaged. The same backscattered waveforms were used to produce peak-to-peak, logarithm of signal energy, as well as entropy images of different types. All of the entropy images exhibit better border delineation and defect contrast than the either peak-to-peak or logarithm of signal energy. The best results are obtained using the joint entropy of the backscattered waveforms with a reference function. Two different references are examined. The first is a reflection of the insonifying pulse from a stainless steel reflector. The second is an approximate optimum obtained from an iterative parametric search. The joint entropy images produced using this reference exhibit three times the contrast obtained in previous studies. These plates were later destructively analyzed to determine size and location of near-surface defects and the results found to agree with the defect location and shape as indicated by the entropy images. In the second study, images of long carbon graphite fibers (50% by weight) in polypropylene thermoplastic are obtained as a first step toward ultrasonic determination of the distributions of fiber position and orientation.

  19. Comparison and analysis of reoperations in two different treatment protocols for trochanteric hip fractures - postoperative technical complications with dynamic hip screw, intramedullary nail and Medoff sliding plate.

    Science.gov (United States)

    Paulsson, Johnny; Stig, Josefine Corin; Olsson, Ola

    2017-08-24

    In treatment of unstable trochanteric fractures dynamic hip screw and Medoff sliding plate devices are designed to allow secondary fracture impaction, whereas intramedullary nails aim to maintain fracture alignment. Different treatment protocols are used by two similar Swedish regional emergency care hospitals. Dynamic hip screw is used for fractures considered as stable within the respective treatment protocol, whereas one treatment protocol (Medoff sliding plate/dynamic hip screw) uses biaxial Medoff sliding plate for unstable pertrochanteric fractures and uniaxial Medoff sliding plate for subtrochanteric fractures, the second (intramedullary nail/dynamic hip screw) uses intramedullary nail for subtrochanteric fractures and for pertrochanteric fractures with intertrochanteric comminution or subtrochanteric extension. All orthopedic surgeries are registered in a regional database. All consecutive trochanteric fracture operations during 2011-2012 (n = 856) and subsequent technical reoperations (n = 40) were derived from the database. Reoperations were analysed and classified into the categories adjustment (percutaneous removal of the locking screw of the Medoff sliding plate or the intramedullary nail, followed by fracture healing) or minor, intermediate (reosteosynthesis) or major (hip joint replacement, Girdlestone or persistent nonunion) technical complications. The relative risk of intermediate or major technical complications was 4.2 (1.2-14) times higher in unstable pertrochanteric fractures and 4.6 (1.1-19) times higher in subtrochanteric fractures with treatment protocol: intramedullary nail/dynamic hip screw, compared to treatment protocol: Medoff sliding plate/dynamic hip screw. Overall rates of intermediate and major technical complications in unstable pertrochanteric and subtrochanteric fractures were with biaxial Medoff sliding plate 0.68%, with uniaxial Medoff sliding plate 1.4%, with dynamic hip screw 3.4% and with intramedullary nail 7.2%. The

  20. Behaviour of Self-Standing CVD Diamond Film with Different Dominant Crystalline Surfaces in Thermal-Iron Plate Polishing

    Institute of Scientific and Technical Information of China (English)

    CHEN Guang-Chao; ZHOU Zu-Yuan; LI Bin; ZHOU You-Liang; J. Askri; LI Cheng-Ming; TANG Wei-Zhong; TONG Yu-Mei; LU Fan-Xiu

    2006-01-01

    @@ Self-standing CVD diamond films with different dominant crystalline surfaces are polished by the thermal-iron plate polishing method. The influence of the dominant crystalline surfaces on polishing efficiency is investigated by measuring the removal rate and final roughness. The smallest rms roughness of 0.14μm is measured with smallest removal rate in the films with the initial (220) dominant crystalline surface. Activation energy for the polishing is analysed by the Arrhenius relation. It is found that the values are 170kJ/mol, 222kJ/mol and 214kJ/mol for the film with t hree different dominant crystalline surfaces. Based on these values, the polishing cause is regarded as the graphitization-controlling process. In the experiment, we find that transformation of the dominant crystalline surfaces from (111) to (220) always appears in the polishing process when we polish the (111) dominant surface.

  1. Study on the output of LD-pumped passively Q-switched subnanosecond microlasers

    Science.gov (United States)

    Cheng, He-jiao; Chen, Hui-min; Ding, Bo-sheng; Cai, De

    2013-09-01

    Caliber mortar projectiles and bombs are now tend to use the laser fuze because of its high accuracy in distance measurement,the strong ability to resist electromagnetic interference, the high angular resolution and the good concealment. Otherwise, the microlaser can bring about some alluring benefits. For instance, it can generate high quality laser beam, which has small divergence angle and high power. So, This paper summarizes some key factors which have impacts on the output of LD-pumped passively Q-switched subnanosecond microlasers, including the initial transmission of the absorber, the reflection of output coupler, the length of the cavity and the radius of the pumping laser beam, and gives the conclusion of the simulation based on the variation of the density of the reversal particle in the resonant cavity derived from the oscillation equation of the LD-pumped passively Q-switched Cr4+:YAG/ Nd:YAG laser, which provides the basis for the design of the passive Q-switched micro lasers which have high power, high repetition frequency and narrow pulse width.

  2. Laser damage properties of broadband low-dispersion mirrors in sub-nanosecond laser pulse.

    Science.gov (United States)

    Zhang, Jinlong; Bu, Xiaoqing; Jiao, Hongfei; Ma, Bin; Cheng, Xinbin; Wang, Zhangshan

    2017-01-09

    Broadband low dispersion (BBLD) mirrors are an essential component in femto-second (fs) pulse laser systems. We designed and produced Tasub>2sub>Osub>5sub>-HfOsub>2sub>/SiOsub>2sub> composite quarter-wave and non-quarter-wave HfOsub>2sub>/SiOsub>2sub> BBLD mirrors for the 30fs petawatt laser system. The laser damage properties of the BBLD mirrors were investigated in an uncompressed sub-nanosecond laser pulse. It showed that the Tasub>2sub>Osub>5sub>-HfOsub>2sub>/SiOsub>2sub> composite BBLD mirror possessed higher LIDT due to the low electric-field intensity (EFI) in the case of the coating without artificial nodules. Nevertheless, the LIDT of the composite mirror was significantly lower than the non-quarter-wave HfOsub>2sub>/SiOsub>2sub> mirror when the nodules exist. The EFI simulation and damage morphology of the nodules analysis demonstrated that the nodule leading to the light intensification in the middle of the boundary between the nodular and the surrounding coating, thus the outermost HfOsub>2sub>/SiOsub>2sub> layers cannot protect the Tasub>2sub>Osub>5sub>/SiOsub>2sub> layers, and resulting to the significantly low LIDT. This study shed some light on the development of high-laser-damage BBLD mirrors for pulse compression laser systems.

  3. Numerical modeling of the intracavity stimulated Raman scattering as a source of subnanosecond optical pulses

    Science.gov (United States)

    Yashkir, Yuri M.; Yashkir, Yuriy Y.

    2004-09-01

    We present a computer numerical model (virtual sub-nanosecond laser) utilizing intracavity stimulated Raman scattering. The goal of this work is to shorten laser output pulses (for which the highly nonlinear frequency conversion process stimulated Raman scattering is used) and to obtain high efficiency (which is enhanced by placing a Raman-active crystal inside the cavity where the fundamental laser frequency intensity is maximal). The following laser components were modeled: a diodepumped solidstate laser active medium (a crystal of the Nd3+:YLF type), a closed cavity for a wave on its fundamental frequency with a Q-switching element and an internal subcavity with a Ramanactive crystal with controlled output coupler transmission at the Raman frequency. The model components are: a numerical integrator of a set of three rate equations (for an inverse population of the laser medium and for the number of fundamental and Stokes frequency photons), random number sources for radiation seeding, and an interactive data input interface and graphic output. A wide range of parameters was investigated and output pulses as short as 0.8 ns were found. The optimal conditions for the maximal peak power of Stokes pulses were determined and the conditions for generating pulse trains for burst laser machining were identified.

  4. A Comparison of Vibroacoustic Response of Isotropic Plate with Attached Discrete Patches and Point Masses Having Different Thickness Variation with Different Taper Ratios

    Directory of Open Access Journals (Sweden)

    Bipin Kumar

    2016-01-01

    Full Text Available A comparison of sound radiation behavior of plate in air medium with attached discrete patches/point masses having different thickness variations with different taper ratio of 0.3, 0.6, and 0.9 is analysed. Finite element method is used to find the vibration characteristics while Rayleigh integral is used to predict the sound radiation characteristics. Minimum peak sound power level obtained is at a taper ratio of 0.6 with parabolic increasing-decreasing thickness variation for plate with four discrete patches. At higher taper ratio, linearly increasing-decreasing thickness variation is another alternative for minimum peak sound power level suppression with discrete patches. It is found that, in low frequency range, average radiation efficiency remains almost the same, but near first peak, four patches or four point masses cause increase in average radiation efficiency; that is, redistribution of point masses/patches does have effect on average radiation efficiency at a given taper ratio.

  5. Direct Numerical Simulation of Transitional and Turbulent Flow Over a Heated Flat Plate Using Finite-Difference Schemes

    Science.gov (United States)

    Madavan, Nateri K.

    1995-01-01

    The work in this report was conducted at NASA Ames Research Center during the period from August 1993 to January 1995 deals with the direct numerical simulation of transitional and turbulent flow at low Mach numbers using high-order-accurate finite-difference techniques. A computation of transition to turbulence of the spatially-evolving boundary layer on a heated flat plate in the presence of relatively high freestream turbulence was performed. The geometry and flow conditions were chosen to match earlier experiments. The development of the momentum and thermal boundary layers was documented. Velocity and temperature profiles, as well as distributions of skin friction, surface heat transfer rate, Reynolds shear stress, and turbulent heat flux were shown to compare well with experiment. The numerical method used here can be applied to complex geometries in a straightforward manner.

  6. Saturation and Dynamic Range of Microchannel Plate-Based X-Ray Imagers

    Energy Technology Data Exchange (ETDEWEB)

    ,

    2012-05-04

    This paper describes recent advances in Monte Carlo simulations of microchannel plate (MCP)–based x-ray detectors, a continuation of ongoing work in this area. A Monte Carlo simulation model has been developed over the past several years by National Security Technologies, LLC (NSTec). The model simulates the secondary electron emission process in an MCP pore and includes the effects of gain saturation. In this work we focus on MCP gain saturation and dynamic range. We have performed modeling and experimental characterizations of L/D = 46, 10-micron diameter, MCP-based detectors. The detectors are typically operated by applying a subnanosecond voltage pulse, which gates the detector on. Agreement between the simulations and experiment is very good for a variety of voltage pulse waveforms ranging in width from 150 to 300 ps. The results indicate that such an MCP begins to show nonlinear gain around 5 × 10^4 electrons per pore and hard saturation around 105 electrons per pore. The simulations show a difference in MCP sensitivity vs voltage for high flux of photons producing large numbers of photoelectrons on a subpicosecond timescale. Simulations and experiments both indicate an MCP dynamic range of 1 to 10,000, and the dynamic range depends on how the voltage is applied.

  7. Non-Reflecting Regions for Finite Difference Methods in Modeling of Elastic Wave Propagation in Plates

    Science.gov (United States)

    Kishoni, Doron; Taasan, Shlomo

    1994-01-01

    Solution of the wave equation using techniques such as finite difference or finite element methods can model elastic wave propagation in solids. This requires mapping the physical geometry into a computational domain whose size is governed by the size of the physical domain of interest and by the required resolution. This computational domain, in turn, dictates the computer memory requirements as well as the calculation time. Quite often, the physical region of interest is only a part of the whole physical body, and does not necessarily include all the physical boundaries. Reduction of the calculation domain requires positioning an artificial boundary or region where a physical boundary does not exist. It is important however that such a boundary, or region, will not affect the internal domain, i.e., it should not cause reflections that propagate back into the material. This paper concentrates on the issue of constructing such a boundary region.

  8. Bacterial deposition to fluoridated and non-fluoridated polyurethane coatings with different elastic modulus and surface tension in a parallel plate and a stagnation point flow chamber

    NARCIS (Netherlands)

    Bakker, D.P.; Huijs, F.M.; Vries, J. de; Klijnstra, J.W.; Busscher, H.J.; Mei, H.C. van der

    2003-01-01

    Deposition of three marine bacterial strains with different cell surface hydrophobicities from artificial seawater to polyurethane coatings on glass with different surface tensions and elastic modulus was studied in situ in a parallel plate (PP) and stagnation point (SP) flow chamber. Different surf

  9. The Influence of a Mandibular Advancement Plate on Polysomnography in Different Grades of Obstructive Sleep Apnea

    Directory of Open Access Journals (Sweden)

    Antti Raunio

    2015-03-01

    Full Text Available Objectives: The purpose of this study was to investigate the effect of a mandibular advancement device on different grades of obstructive sleep apnea using a relatively simple test for the apnea-hypopnea index to determine if a mandibular device will be effective. Material and Methods: A total of 68 patients with obstructive sleep apnea syndrome (OSAS including, 31 with mild, 23 with moderate and 14 with severe OSAS were treated with a mandibular advancement device (MAD and monitored with polysomnography. Results: 25 of the 31 mild, 15 of the 23 moderate and 2 of the 14 severe OSAS patients were cured of their OSAS if a post treatment apnea-hypopnea index of less than 5 is regarded as cured. The odds ratios for success with MAD therapy are 3 for women over men, 14.9 for mild obstructive sleep apnea, 5.42 for moderate obstructive sleep apnea if severe obstructive sleep apnea is assigned an odds ratio of 1. Conclusions: The use of the apnea-hypopnea index alone is useful in mild and moderate disease to predict the effectiveness of mandibular advancement device. Treatment with a mandibular advancement device is very effective in treating mild and moderate obstructive sleep apnea. Conservative treatment with a mandibular advancement device can be successful in less severe grades of sleep apnea and may be an alternative for non-surgical patients with severe obstructive sleep apnea intolerant of Continuous Positive Airway Pressure management.

  10. Tracking rare-isotope beams with microchannel plates

    CERN Document Server

    Rogers, A M; Lynch, W G; Tsang, M B; Lee, J; Bazin, D; Coupland, D; Henzl, V; Henzlova, D; Kilburn, M; Wallace, M S; Youngs, M; Delaunay, F; Famiano, M; Shapira, D; Jones, K L; Schmitt, K T; Sun, Z Y

    2013-01-01

    A system of two microchannel-plate detectors has been successfully implemented for tracking projectile-fragmentation beams. The detectors provide interaction positions, angles, and arrival times of ions at the reaction target. The current design is an adaptation of an assembly used for low-energy beams ($\\sim$1.4 MeV/nucleon). In order to improve resolution in tracking high-energy heavy-ion beams, the magnetic field strength between the secondary-electron accelerating foil and the microchannel plate had to be increased substantially. Results from an experiment using a 37-MeV/nucleon ${}^{56}$Ni beam show that the tracking system can achieve sub-nanosecond timing resolution and a position resolution of $\\sim$1 mm for beam intensities up to $5\\times10^{5}$ pps.

  11. Biomechanical interactions of different mini-plate fixations and maxilla advancements in the Le Fort I Osteotomy: a finite element analysis.

    Science.gov (United States)

    Huang, Shao-Fu; Lo, Lun-Jou; Lin, Chun-Li

    2016-12-01

    This study investigates the biomechanical interaction of different mini-plate fixation types (shapes/sizes and patterns) with segmental advancement levels on the Le Fort I osteotomy using the non-linear finite element (FE) approach. Nine models were generated under a standard 1-piece LeFort I osteotomy for advancement with 3, 6 and 9 mm distances and four mini-plates with three fixation patterns including LL, LI, and II patterns placed on the maxillae models by integrating computed tomography images and computer-aided design system. The axial and oblique occlusal forces were 250 N applied to each premolar/molar and 125 N applied at 30° inclination to the tooth long axis and from palatal to buccal, respectively. The relative micro-movement values between the two maxillary bone segments and maximum mini-plate stress increased obviously with maxilla advancement increment and the increasing trend can be fitted by exponential curve. The corresponding values in II mini-plate fixation presented apparently high values in all simulated cases. The mini-plate stress concentration locations were found at the bending regions to increase high fracture risk. The mini-plate yield strength can be mapped to a critical (limited) advancement for three types of fixations for safe consideration. This study concluded that L-shaped mini-plates with lateral fixation are recommended to provide better stability. The risk for mini-plate fracture and bone relapse increases when maxillary advancement is larger than a critical value of 5 mm in the Le Fort I osteotomy.

  12. Plate selection for fixation of extra-articular distal humerus fractures: a biomechanical comparison of three different implants.

    Science.gov (United States)

    Scolaro, John A; Hsu, Jason E; Svach, David J; Mehta, Samir

    2014-12-01

    Operative fixation of extra-articular distal humerus using a single posterolateral column plate has been described but the biomechanical properties or limits of this technique is undefined. The purpose of this study was to evaluate the mechanical properties of distal humerus fracture fixation using three standard fixation constructs. Two equal groups were created from forty sawbones humeri. Osteotomies were created at 80mm or 50mm from the tip of the trochlea. In the proximal osteotomy group, sawbones were fixed with an 8-hole 3.5mm LCP or with a 6-hole posterolateral plate. In the distal group, sawbones were fixed with 9-hole medial and lateral 3.5mm distal humerus plates and ten sawbones were fixed with a 6-hole posterolateral plate. Biomechanical testing was performed using a servohydraulic testing machine. Testing in extension as well as internal and external rotation was performed. Destructive testing was also performed with failure being defined as hardware pullout, sawbone failure or cortical contact at the osteotomy. In the proximal osteotomy group, the average bending stiffness and torsional stiffness was significantly greater with the posterolateral plate than with the 3.5mm LCP. In the distal osteotomy group, the average bending stiffness and torsional stiffness was significantly greater with the posterolateral plate than the 3.5mm LCP. In extension testing, the yield strength was significantly greater with the posterolateral plate in the proximal osteotomy specimens, and the dual plating construct in the distal osteotomy specimens. The yield strength of specimens in axial torsion was significantly greater with the posterolateral plate in the proximal osteotomy specimens, and the dual plating construct in the distal osteotomy specimens. Limited biomechanical data to support the use of a pre-contoured posterolateral distal humerus LCP for fixation of extra-articular distal humerus exists. We have found that this implant provided significantly greater

  13. Response of magnetic tunnel junction-based spin-torque oscillator to series of sub-nanosecond magnetic pulses

    Science.gov (United States)

    Nagasawa, Tazumi; Suto, Hirofumi; Kudo, Kiwamu; Mizushima, Koichi; Sato, Rie

    2016-11-01

    Spin-torque oscillator (STO) read heads with a high data transfer rate for hard disk drives have been proposed. To investigate the oscillation stability and frequency agility of the STO under magnetic pulses, we measured the response waveforms of the STO to a series of sub-nanosecond magnetic pulses and calculated the delay-detection output signal from the STO waveforms. We found that stable oscillation was maintained under the magnetic pulses and that the delay-detection output signal reproduced the applied pulse pattern. The results indicate that the STO read heads can operate at data transfer rates higher than 2 Gbits/s.

  14. Finite Difference Analysis of Radiative Free Convection Flow Past an Impulsively Started Vertical Plate with Variable Heat and Mass Flux

    Directory of Open Access Journals (Sweden)

    V. Ramachandra Prasad

    2011-01-01

    Full Text Available A numerical solution of the unsteady radiative free convection flow of an incompressible viscous fluid past an impulsively started vertical plate with variable heat and mass flux is presented here. This type of problem finds application in many technological and engineering fields such as rocket propulsion systems, spacecraft re-entry aerothermodynamics, cosmical flight aerodynamics, plasma physics, glass production and furnace engineering. The fluid is gray, absorbing-emitting but non-scattering medium and the Rosseland approximation is used to describe the radiative heat flux in the energy equation. The governing non-linear, coupled equations are solved using an implicit finite difference scheme. Numerical results for the velocity, temperature, concentration, the local and average skinfriction, the Nusselt and Sherwood number are shown graphically, for different values of Prandtl number, Schmidt number, thermal Grashof number, mass Grashof number, radiation parameter, heat flux exponent and the mass flux exponent. It is observed that, when the radiation parameter increases, the velocity and temperature decrease in the boundary layer. The local and average skin-friction increases with the increase in radiation parameter. For increasing values of radiation parameter the local as well as average Nusselt number increases.

  15. Detection system for inclusion defects in hot-rolled steel plates using MFLT with two different magnetizing strengths

    Science.gov (United States)

    Yotsuji, Junichi; Koshihara, Takahiro

    2014-02-01

    Recently, steel can manufacturing requires higher quality because otherwise minute non-metallic inclusions in thin sheets cause cracks and result in a burst during pressurization after the pressing process. Quality testing systems have already been installed in the final process in steel plants, but if there were another inspection in an earlier step, for example, at the hot strip mill, the mass manufacture of nonconforming products could be avoided and maintaining quality control would be more efficient. In order to detect inclusion defects in hot-rolled steel plates, the authors developed a new technique for MFLT (Magnetic Flux Leakage Testing) using different magnetizing forces. According to an analysis of the noise factors in MFLT, it was found that the signals generated from the scale layer on a steel surface are dominant. A different magnetizing force method is the used to decrease this overpowering noise level in MFLT. In this paper, it was confirmed that inclusions larger than 160μm in diameter and less than 0.45mm in depth can be detected utilizing this method.

  16. Differences in physico-mechanical behaviors of resol(e) and novolac type phenolic resin based composite bipolar plate for proton exchange membrane (PEM) fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Kakati, Biraj Kumar [Department of Chemical Engineering, Indian Institute of Technology Guwahati, North Guwahati, PIN 781 039, Dist. Kamrup (Assam) (India); Deka, Dhanapati [Department of Energy, Tezpur University, Tezpur 784 028, Dist. Sonitpur (Assam) (India)

    2007-09-15

    Composite bipolar plates for Proton Exchange Membrane Fuel Cell (PEMFC) are prepared by compression molding technique using polymer as binder and graphite as electric filler material with some other reinforcements. Study on the effect of resole and novolac type phenolic resin on the properties of composite bipolar plate, such as bulk density, porosity, bulk conductivity, hardness, flexural strength, etc. shows that both of the resin shows different physico-mechanical properties. Moreover, single cell performance analysis also shows variation for resole and novolac based composites. A novel concept of triple continuous structure to provide graphite polymer blends with high electrical conductivity, high shore hardness, high flexural strength, less porosity and low density has been proposed and study on the effect of different types of phenolic resin on the properties and performance of bipolar plate reveals that novolac type powdered phenolic resin gives better mechanical properties than resole type phenolic resin. However, resole type phenolic resin compound has slightly higher electrical conductivity due to more number of polar -OH group presents on its cured form. But due to the less porosity and higher mechanical strength, bipolar plates with novolac type phenolic resin gives better performance in I-V analysis than bipolar plates with resole type phenolic resin. (author)

  17. Analysis of the results of different types of diaphyseal tibial fractures with intraosseous and of plate osteosynthesis

    Directory of Open Access Journals (Sweden)

    V. V. Pisarev

    2013-01-01

    Full Text Available Aim of this study - comparative assesment of treatment outcomes of different types of diaphyseal shin fractures in patients with bone and intraosteal lackable osteosynthesis. Material and methods. We examined 222 patients with fused diaphyseal shin fractures. In 122 patients close reduction and intraosteal lackable osteosynthesis of shin bones was performed, in 100 - open reduction and osteosynthesis of shin bones with plates LCDCP All patients were divided into subgroups according to АО/ASIF classification (fractures type А, В, С. The evaluation of the results was done in two years period after surgery with questionnaire SF36, outpatients clinic cards analysis, CITO cards study outcomes of fractures, rheovasography and X-ray examination. Results. We found that in patients with fractures types A and В these two types of osteosynthesis lead to similar results according to questionnaire SF36, comparable with control group. Bone osteosynthesis in treatment of fractures type С results in higher quality of life, comparable with control group, than intraosteal. Indicators of treatment outcomes in accordance with CITO card in bone osteosynthesis were higher than in intraosteal. In bone osteosynthesis of fractures type A the terms of temporary disability and fusion significantly lower than in intraosteal osteosynthesis of the similar fractures. Reduce of the tolerance to heavy physical stress in patients with fractures type С in intraosteal osteosynthesis determined by low blood flow in shin. Treatment of shin fractures with bone and intraosteal osteosynthesis follows by equal risks of complications.

  18. Leadless Chip Carrier Packaging and CAD/CAM-Supported Wire Wrap Interconnect Technology for Subnanosecond ECL.

    Science.gov (United States)

    1981-11-01

    Aided Manufacturing Software J. M. Dubin : CAD/CAM Demonstration Circuit Design, Fabrica- tion, and Test L. M. Krueger: ECL Design Protocols R. D...the electro - plating fingers is further compounded by the presence of yet another set of plating fingers, which may be detected in Figure 24 between the

  19. Generalized Fibonacci zone plates

    CERN Document Server

    Ke, Jie; Zhu, Jianqiang

    2015-01-01

    We propose a family of zone plates which are produced by the generalized Fibonacci sequences and their axial focusing properties are analyzed in detail. Compared with traditional Fresnel zone plates, the generalized Fibonacci zone plates present two axial foci with equal intensity. Besides, we propose an approach to adjust the axial locations of the two foci by means of different optical path difference, and further give the deterministic ratio of the two focal distances which attributes to their own generalized Fibonacci sequences. The generalized Fibonacci zone plates may allow for new applications in micro and nanophotonics.

  20. Comparison of microstructural properties and Charpy impact behaviour between different plates of the Eurofer97 steel and effect of isothermal ageing

    Science.gov (United States)

    Stratil, Ludek; Hadraba, Hynek; Bursik, Jiri; Dlouhy, Ivo

    2011-09-01

    The microstructure and fracture properties of the Eurofer97 steel plates of thickness 14 mm and 25 mm were investigated in as-received state and in state after long-term thermal ageing (550 °C/5000 h). Detailed microstructure studies were carried out by means of optical light, electron and quantitative electron microscopy. Mechanical properties were evaluated by means of Charpy impact testing and hardness testing and fracture surfaces were fractographically analysed in macro and microscales. The microstructure of the Eurofer97 consisted of tempered martensite with M 23C 6 and MX precipitates. Microstructure of 14 mm plate was more homogenous and fine grained than 25 mm plate. Due to different microstructure the tDBTT of thicker plate was on +10 °C higher than for 14 mm plate for which reached -60 °C. Slight microstructural changes on the level of subgrain consisting of their partial recrystallization and slight carbide coarsening were observed after applied ageing. The isothermal ageing caused evident shift in tDBTT about +5 °C, which was most likely caused by recrystallization of subgrains.

  1. MyPlate Food Guide

    Science.gov (United States)

    ... Choosing the Right Sport for You Shyness MyPlate Food Guide KidsHealth > For Teens > MyPlate Food Guide Print ... other sugary drinks. Avoid oversized portions. continue Five Food Groups Different food groups meet different nutrition needs. ...

  2. Detachment of colloidal particles from collector surfaces with different electrostatic charge and hydrophobicity by attachment to air bubbles in a parallel plate flow chamber

    NARCIS (Netherlands)

    Suarez, CG; van der Mei, HC; Busscher, HJ

    1999-01-01

    The detachment of polystyrene particles adhering to collector surfaces with different electrostatic charge and hydrophobicity by attachment to a passing air bubble has been studied in a parallel plate flow chamber. Particle detachment decreased linearly with increasing air bubble velocity and

  3. Detachment of colloidal particles from collector surfaces with different electrostatic charge and hydrophobicity by attachment to air bubbles in a parallel plate flow chamber

    NARCIS (Netherlands)

    Suarez, CG; van der Mei, HC; Busscher, HJ

    1999-01-01

    The detachment of polystyrene particles adhering to collector surfaces with different electrostatic charge and hydrophobicity by attachment to a passing air bubble has been studied in a parallel plate flow chamber. Particle detachment decreased linearly with increasing air bubble velocity and decrea

  4. Image Shutters: Gated Proximity-Focused Microchannel-Plate (MCP) Wafer Tubes Versus Gated Silicon Intensified Target (SIT) Vidicons

    Science.gov (United States)

    Yates, G. J.; King, N. S. P.; Jaramillo, S. A.; Ogle, J. W.; Noel, B. W.; Thayer, N. N.

    1983-03-01

    The imaging characteristics of two fast image shutters used for recording the spatial and temporal evolution of transient optical events in the nanosecond range have been studied. Emphasis is on the comparative performances of each shutter type under similar conditions. Response data, including gating speed, gain, dynamic range, shuttering efficiency, and resolution for 18 and 25-mm-diam proximity-focused microchannel-plate (MCP) intensifiers are com-pared with similar data for a prototype electrostatically-focused 25-mm-diam gated silicon-intensified-target (SIT) vidicon currently under development for Los Alamos National Laboratory. Several key parameters critical to optical gating speed have been varied in both tube types in order to determine the optimum performance attainable from each design. These include conductive substrate material and thickness used to reduce photocathode resistivity, spacing between gating electrodes to minimize interelectrode capacitance, the use of con-ductive grids on the photocathode substrate to permit rapid propagation of the electrical gate pulse to all areas of the photocathode, and different package geometries to provide a more effective interface with external biasing and gating circuitry. For comparable spatial resolution, most 18-mm-diam MCPs require gate times > 2.5 ns while the fastest SIT has demonstrated sub-nanosecond optical gates as short as r 400 ± 50 ps for full shuttering of the 25-mm-diam input window.

  5. Image shutters: Gated proximity-focused Microchannel Plate (MCP) wafer tubes versus gated Silicon Intensified Target (SIT) vidicons

    Science.gov (United States)

    Yates, G. J.; King, N. S. P.; Jaramillo, S. A.; Ogle, J. W.; Noel, B. W.; Thayer, N. N.

    Response data, including gating speed, gain, dynamic range, shuttering efficiency, and resolution for 18- and 25-mm-diam proximity-focused microchannel-plate (MCP) intensifiers are compared with similar data for a prototype electrostatically-focused 25-mm-diam gated silicon-intensified-target (SIT) vidicon. Conductive substrate material and thickness used to reduce photocathode resistivity, spacing between gating electrodes to minimize inter-electrode capacitance, the use of conductive grids on the photocathode substrate to permit rapid propagation of the electrical gate pulse to all areas of the photocathode, and different package geometries to provide a more effective interface with external biasing and gating circuitry were varied in both tube types to determine optimal performance from each design. For comparable spatial resolution, most 18-mm-diam MCPs require gate times 2.5 ns while the fastest SIT has demonstrated sub-nanosecond optical gates as short as approximately 400 + or - 50 ps for full shuttering of the 25-mm-diam input window.

  6. Air bubble-induced detachment of polystyrene particles with different sizes from collector surfaces in a parallel plate flow chamber

    NARCIS (Netherlands)

    Gomez-Suarez, C; van der Mei, HC; Busscher, HJ

    2001-01-01

    Particle size was found to be an important factor in air bubble-induced detachment of colloidal particles from collector surfaces in a parallel plate flow chamber and generally polystyrene particles with a diameter of 806 nm detached less than particles with a diameter of 1400 nm. Particle

  7. Standard Test Method for Water Penetration of Flat Plate Solar Collectors by Uniform Static Air Pressure Difference

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1986-01-01

    1.1 This test method covers the determination of the resistance of flat plate solar collectors to water penetration when water is applied to their outer surfaces with a static air pressure at the outer surface higher than the pressure at the interior of the collector. 1.2 This test method is applicable to any flat plate solar collector. 1.3 The proper use of this test method requires a knowledge of the principles of pressure and deflection measurement. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary information is contained in Section 6.

  8. Implementation of sub-nanoseconds TDC in FPGA: applications to time-of-flight analysis in muon radiography

    CERN Document Server

    Marteau, J; Gibert, D; Jourde, K; Gardien, S; Girerd, C; Ianigro, J -C

    2014-01-01

    Time-of-flight (tof) techniques are standard techniques in high energy physics to determine particles propagation directions. Since particles velocities are generally close to c, the speed of light, and detectors typical dimensions at the meter level, the state-of-the-art tof techniques should reach sub-nanosecond timing resolution. Among the various techniques already available, the recently developed ring oscillator TDC ones, implemented in low cost FPGA, feature a very interesting figure of merit since a very good timing performance may be achieved with limited processing ressources. This issue is relevant for applications where unmanned sensors should have the lowest possible power consumption. Actually this article describes in details the application of this kind of tof technique to muon tomography of geological bodies. Muon tomography aims at measuring density variations and absolute densities through the detection of atmospheric muons flux's attenuation, due to the presence of matter. When the measure...

  9. Promoting ossification of calvarial defects in craniosynostosis surgery by demineralized bone plate and bone dust in different age groups.

    Science.gov (United States)

    Savolainen, M; Ritvanen, A; Hukki, J; Vuola, P; Telkkä, J; Leikola, J

    2017-01-01

    Correction of calvarial defects after calvarial vault reconstruction (CVR) is challenging in craniosynostosis patients of advanced age and typically employs autologous bone. Demineralized bone matrix (DBM) is a potential alternative material for autologous bone, but its use has not been extended to correct calvarial defects. CVR patients operated at the Department of Plastic Surgery, Helsinki University Hospital, during 2008-2010 were retrospectively reviewed. Inclusion criteria of the study were CVR patients who received DBM plate, with or without bone dust, on calvarial defects and who had suitable uncovered defect on the contralateral side as control. This study included 17 craniosynostosis and one positional plagiocephaly patient, whose mean age was 6.9 years (range 0.9-19 years). The mean follow-up time was 5.6 years. The fusion degree of all defects was measured from 1 week to 1 year postoperatively using three-dimensional computed tomography (3D CT) images by the OsiriX(©) method. Medical records were reviewed for DBM-related complications. A total of 26 defects were covered with a DBM plate (mean area 11.1 cm(2)) and 26 control defects were identified (mean area 7.8 cm(2)). The mean fusion degree of the DBM defects was 74% and 54% for the controls (p plate is a safe and useful material to promote ossification in calvarial defects in CVR. Furthermore, DBM appears to be more effective in older patients (>30 months) than in younger patients or when used with bone dust. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. Comparison of Different Analytic Solutions to Axisymmetric Squeezing Fluid Flow between Two Infinite Parallel Plates with Slip Boundary Conditions

    Directory of Open Access Journals (Sweden)

    Hamid Khan

    2012-01-01

    Full Text Available We investigate squeezing flow between two large parallel plates by transforming the basic governing equations of the first grade fluid to an ordinary nonlinear differential equation using the stream functions ur(r,z,t=(1/r(∂ψ/∂z and uz(r,z,t=−(1/r(∂ψ/∂r and a transformation ψ(r,z=r2F(z. The velocity profiles are investigated through various analytical techniques like Adomian decomposition method, new iterative method, homotopy perturbation, optimal homotopy asymptotic method, and differential transform method.

  11. Expression of the difference between the Cold (Han) and Hot (Re) natures of traditional Chinese medicines (Strobal and Rhubarb) based on the cold/hot plate differentiating assay.

    Science.gov (United States)

    Zhao, HaiPing; Zhao, YanLing; Wang, JiaBo; Li, HanBing; Ren, YongShen; Zhou, CanPing; Yan, Dan; Xiao, XiaoHe

    2009-12-01

    In this study, objective differences between the Cold (Han) and Hot (Re) nature of traditional Chinese medicines, e.g. Strobal and Rhubarb, are determined by using a cold/hot plate differentiation technology. A novel, self-designed cold/hot plate differentiating instrument, with methodological study, was used to investigate the intervention of Strobal and Rhubarb on the temperature tropism of mice. Compared with the ICR and BALB/c mice, it was found that KM mice on the cold/hot plate were more sensitive to the change of temperature, within the tolerant temperature range of 15-40 degrees C. The temperature tropism behavior of mice is influenced by treatment with Rhubarb and Strobal, as is the activity of ATPase in liver tissue. These trends are consistent with the definition of the Cold/Hot nature of Chinese medicines based on traditional Chinese medicinal theory. This study showed that the differences of the Cold/Hot nature of traditional Chinese medicines. might be objectively represented by the temperature tropism of animal by means of cold/hot differentiating assay.

  12. Anode initiated impulse breakdown in water: the dependence on pulse rise time for nanosecond and sub-nanosecond pulses and initiation mechanism based on electrostriction

    CERN Document Server

    Seepersad, Yohan; Dobrynin, Danil

    2015-01-01

    The effect of the voltage rise time on nanosecond and sub-nanosecond impulse breakdown of distilled water is studied. The dependence of anode initiated streamer inception on this parameter is shown to be more intricate than previously reported, particularly as it relates to mechanisms directly in the liquid phase. Dynamics of the emission phase for sub-nanosecond pulses with 600ps rise time are presented to enable comparison with previous work on nanosecond initiation features. Schlieren imaging is also used to show the development of optical density perturbations and rarefactions as a result of electrostriction in the liquid which were previously found for nanosecond pulses as well. The mechanism of nanopore generation in the liquid due to fast impulses proposed by Shneider, Pekker and Fridman is used to explain the results.

  13. Integrating rift inheritance and different plate kinematic scenarios in Alpine models: implications for the interpretation of the deep structures of the Alps

    Science.gov (United States)

    Manatschal, Gianreto; Tugend, Julie; Chenin, Pauline; Nirrengarten, Michael; Epin, Marie-Eva; Picazo, Suzanne; Mohn, Geoffroy

    2017-04-01

    The Alps result from the imbrication of its former rifted margins and intervening oceanic basins. Thus, the formation and evolution of this orogen depends, among other factors, on the overall kinematic evolution, nature and size of the oceanic domain, and on the occurrence of inherited rift structures. Most Alpine models mainly focus on the compressional history. Only few of them integrate plate kinematic scenarios and rift/oceanic models based on the latest observations and concepts derived from the research developed at rifted margins. In this presentation we will mainly focus on three recent outcomes of this research that may significantly impact the interpretation of the Alps. 1) The nature of the J-magnetic anomaly (including anomaly M0) as an oceanic isochron is questioned as a result of the re-evaluation of the breakup processes offshore Iberia-Newfoundland. As a consequence, classical kinematic models proposed for the Iberia plate and used also for the Alpine domain need to be revised. 2) The size of the oceanic basins prior to their subduction in the Alpine domain indeed depends on the plate kinematic model. New plate kinematic models, in line with studies of the mantle rocks derived from the Alpine ophiolites, do not show any evidence for an unequivocal mature oceanic domain with depleted mantle lithosphere. 3) Hyperextended magma-poor rifted margins, such as the fossil Alpine Tethys margins, include extremely thinned continental crust (<10 km) and exhumed serpentinized mantle with minor magmatic additions. Rheological weaknesses inherited from hyperextension are likely to control the location of decoupling levels and formation of buttresses during orogeny resulting in important implications for the nature of orogenic roots and restorations. In our presentation we will review different plate kinematic scenarios and their consequences for Alpine restorations (i.e., maximum vs. minimum size of the oceanic domains, widths of hyper-extended domains and timing

  14. Leadless Chip Carrier Packaging and CAD/CAM (Computer-Aided Design/Computer-Aided Manufacturing) Supported Wire Wrap Interconnect Technology for Subnanosecond ECL (Emitter Coupled Logic).

    Science.gov (United States)

    1982-12-01

    Operational Results The overall ring system clock rate is determined by the longest node-to-node wire pathway , which in this system is four feet. This length...Clock; 18.2 ns Period; 4 Foot Internode Separation; CERDI P Encapsulation) Node Input Register Ring Register Ring Data Signal OLoado Pulse "Clear* Pulse...NETWORK FABRICATED WITH SUBNANOSECOND ECL (55 MHz Clock; 18.2 ns Period; 4 Foot Internode Separation; CERDIP Encapsulation) Ring Data Signal: Differential

  15. Three-dimensional analytical solution for a transversely isotropic functionally graded piezoelectric circular plate subject to a uniform electric potential difference

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    This paper studies the problem of a functionally graded piezoelectric circular plate subjected to a uniform electric potential difference between the upper and lower surfaces. By assuming the generalized displacements in appropriate forms,five differential equations governing the generalized displacement functions are derived from the equilibrium equations. These displacement functions are then obtained in an explicit form,which still involve four undetermined integral constants,through a step-by-step integration which properly incorporates the boundary conditions at the upper and lower surfaces. The boundary conditions at the cylindrical surface are then used to determine the integral constants. Hence,three-dimen sional analytical solutions for electrically loaded functionally graded piezoelectric circular plates with free or simply-supported edge are completely determined. These solutions can account for an arbitrary material variation along the thickness,and thus can be readily degenerated into those for a homogenous plate. A numerical example is finally given to show the validity of the analysis,and the effect of material inhomogeneity on the elastic and electric fields is discussed.

  16. Hierarchical self-organization of tectonic plates

    OpenAIRE

    2010-01-01

    The Earth's surface is subdivided into eight large tectonic plates and many smaller ones. We reconstruct the plate tessellation history and demonstrate that both large and small plates display two distinct hierarchical patterns, described by different power-law size-relationships. While small plates display little organisational change through time, the structure of the large plates oscillate between minimum and maximum hierarchical tessellations. The organization of large plates rapidly chan...

  17. Finite difference analysis of hydromagnetic mixed convective mass diffusion boundary layer flow past an accelerated vertical porous plate through a porous medium with suction

    Energy Technology Data Exchange (ETDEWEB)

    Das, S.S. [Department of Physics, K.B.D.A.V. College, Nirakarpur, Khordha-752 019 (Odisha) (India); Saran, M.R. [Department of Physics, Maharishi College of Natural Law, Sahid Nagar, Bhubaneswar-751 007 (Odisha) (India); Mohanty, S. [Department of Chemistry, Christ College, Mission Road, Cuttack-753 001 (Odisha) (India); Padhy, R.K. [Department of Physics, ODM Public School, Shishu Vihar, Patia, Bhubaneswar-751 024 (Odisha) (India)

    2013-07-01

    This paper focuses on the unsteady hydromagnetic mixed convective heat and mass transfer boundary layer flow of a viscous incompressible electrically conducting fluid past an accelerated infinite vertical porous flat plate in a porous medium with suction in presence of foreign species such as H2, He, H2O vapour and NH3. The governing equations are solved both analytically and numerically using error function and finite difference scheme. The flow phenomenon has been characterized with the help of flow parameters such as magnetic parameter (M), suction parameter (a), permeability parameter (Kp), Grashof number for heat and mass transfer (Gr, Gc), Schmidt number (Sc) and Prandtl number (Pr). The effects of the above parameters on the fluid velocity, temperature, concentration distribution, skin friction and heat flux have been analyzed and the results are presented graphically and discussed quantitatively for Grashof number Gr>0 corresponding to cooling of the plate. It is observed that a growing magnetic parameter (M) retards the velocity of the flow field at all points and a greater suction leads to a faster reduction in the velocity of the flow field. Further, as we increase the permeability parameter (Kp) and the Grashof numbers for heat and mass transfer (Gr, Gc) the velocity of the flow field enhances at all points, while a greater suction/Prandtl number leads to a faster cooling of the plate. It is also observed that a more diffusive species has a significant decrease in the concentration boundary layer of the flow field and a growing suction parameter enhances both skin friction (T') and heat flux (Nu) at the wall corresponding to cooling of the plate (Gr>0).

  18. Study of radon exhalation from phosphogypsum plates and blocks from different origins; Estudo da exalacao de radonio em placas e tijolos de fosfogesso de diferentes procedencias

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Lucas Jose Pereira da

    2011-07-01

    Phosphogypsum is a waste of the fertilizer industry that concentrates radionuclides. In this work, the {sup 222}Rn exhalation rate from phosphogypsum plates and blocks from different origins used at dwellings construction was studied. The {sup 222}Rn exhalation rate was determined through the accumulation chamber technique with solid state nuclear track detectors (SSNTD). The effective dose for an individual living in a residence built with phosphogypsum based materials was evaluated. It also was calculated the {sup 222}Rn exhalation rate through the UNSCEAR model, from the {sup 226}Ra concentration in the materials, in order to compare the experimental results. It was evaluated the contribution of building component (paint) to the reduction of {sup 222}Rn exhalation rate. The plates and blocks were manufactured with phosphogypsum from Bunge Fertilizantes, Ultrafertil and Fosfertil. Blocks manufactured with ordinary gypsum was also evaluated. The average results obtained were 0.19 {+-} 0.06 Bq m-2 h-1, 1.3 {+-} 0.3 Bq m{sup -2} h{sup -1} and 0.41 {+-} 0.07 Bq m{sup -2} h{sup -1} for plates manufactured with phosphogypsum from Bunge Fertilizer, Ultrafertil and Fosfertil, respectively. For the phosphogypsum blocks the values were 0.11 {+-} 0.01 Bq m{sup -2} h-1, 1.2 {+-} 0.6 Bq m{sup -2} h{sup -1}, 0.47 {+-} 0.15 Bq m{sup -2} h{sup -1}, for Bunge, Ultrafertil and Fosfertil. The blocks manufactured with ordinary gypsum presented average value of 0.18 {+-} 0.08 Bq m{sup -2} h'-{sup 1}. All phosphogypsum plates and blocks evaluated in this study presented effective dose for radon inhalation lower than the recommended value of 1mSv y{sup -1}, the annual effective dose limit for public exposure by International Commission on Radiological Protection. (author)

  19. Comparative evaluation of image quality in computed radiology systems using imaging plates with different usage time; Avaliacao comparativa da qualidade da imagem em sistemas de radiologia computadorizada utilizando Imaging Plates com diferentes tempos de uso

    Energy Technology Data Exchange (ETDEWEB)

    Lazzaro, M.V.; Luz, R.M. da; Capaverde, A.S., E-mail: marcos.lazzaro@acad.pucrs.br [Hospital Sao Lucas (PUC-RS), Porto Alegre, RS (Brazil); Silva, A.M. Marques da [Pontificia Universidade Catolica do Rio Grande do Sul (PUC-RS), Porto Alegre, RS (Brazil). Faculdade de Fisica

    2015-04-15

    Computed Radiology (CR) systems use imaging plates (IPs) for latent image acquisition. Taking into account the quality control (QC) of these systems, imaging plates usage time is undetermined. Different recommendations and publications on the subject suggest tests to evaluate these systems. The objective of this study is to compare the image quality of IPs of a CR system, in a mammography service, considering the usage time and consistency of assessments. 8 IPs were used divided into two groups: the first group included 4 IPs with 3 years of use (Group A); the second group consisted of 4 new IPs with no previous exposure (Group B). The tests used to assess the IP's quality were: Uniformity, Differential Signal to Noise Ratio (SDNR), Ghost Effect and Figure of Merit (FOM). Statistical results show that the proposed tests are shown efficient in assessing the conditions of image quality obtained in CR systems in mammography and can be used as determining factors for the replacement of IP's. Moreover, comparing the two sets of IP, results led to the replacement of all the set of IP’s with 3 years of use. This work demonstrates the importance of an efficient quality control, not only with regard to the quality of IP's used, but in the acquisition system as a whole. From this work, these tests will be conducted on an annual basis, already targeting as future work, monitoring the wear of IP's Group B and the creation of a baseline for analysis and future replacements. (author)

  20. Wood and humus decay strategies by white-rot basidiomycetes correlate with two different dye decolorization and enzyme secretion patterns on agar plates.

    Science.gov (United States)

    Barrasa, José M; Blanco, María N; Esteve-Raventós, Fernando; Altés, Alberto; Checa, Julia; Martínez, Angel T; Ruiz-Dueñas, Francisco J

    2014-11-01

    During several forays for ligninolytic fungi in different Spanish native forests, 35 white-rot basidiomycetes growing on dead wood (16 species from 12 genera) and leaf litter (19 species from 10 genera) were selected for their ability to decolorize two recalcitrant aromatic dyes (Reactive Blue 38 and Reactive Black 5) added to malt extract agar medium. In this study, two dye decolorization patterns were observed and correlated with two ecophysiological groups (wood and humus white-rot basidiomycetes) and three taxonomical groups (orders Polyporales, Hymenochaetales and Agaricales). Depending on the above groups, different decolorization zones were observed on the dye-containing plates, being restricted to the colony area or extending to the surrounding medium, which suggested two different decay strategies. These two strategies were related to the ability to secrete peroxidases and laccases inside (white-rot wood Polyporales, Hymenochaetales and Agaricales) and outside (white-rot humus Agaricales) of the fungal colony, as revealed by enzymatic tests performed directly on the agar plates. Similar oxidoreductases production patterns were observed when fungi were grown in the absence of dyes, although the set of enzyme released was different. All these results suggest that the decolorization patterns observed could be related with the existence of two decay strategies developed by white-rot basidiomycetes adapted to wood and leaf litter decay in the field.

  1. Using plate mapping to examine portion size and plate composition for large and small divided plates.

    Science.gov (United States)

    Sharp, David E; Sobal, Jeffery; Wansink, Brian

    2014-12-01

    Does the size of a plate influence the serving of all items equally, or does it influence the serving of some foods - such as meat versus vegetables - differently? To examine this question, we used the new method of plate mapping, where people drew a meal on a paper plate to examine sensitivity to small versus large three-compartment divided plates in portion size and meal composition in a sample of 109 university students. The total drawn meal area was 37% bigger on large plates than small plates, which showed that the portion of plate coverage did not differ by plate size. Men and women drew bigger vegetable portions and men drew bigger meat portions on large plates when compared to small plates. These results suggest that men and women are differentially sensitive to plate size for overall meal size and for meal composition. Implications for decreasing portion size and improving meal balance are that plate size may influence portion size and change the proportions of foods served.

  2. Pixel readout ASIC for an APD based 2D X-ray hybrid pixel detector with sub-nanosecond resolution

    Energy Technology Data Exchange (ETDEWEB)

    Thil, Ch., E-mail: christophe.thil@ziti.uni-heidelberg.d [Heidelberg University, Institute of Computer Engineering, B6, 26, 68161 Mannheim (Germany); Baron, A.Q.R. [RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Fajardo, P. [ESRF, Polygone Scientifique Louis Neel, 6, rue Jules Horowitz, 38000 Grenoble (France); Fischer, P. [Heidelberg University, Institute of Computer Engineering, B6, 26, 68161 Mannheim (Germany); Graafsma, H. [DESY, Notkestrasse 85, 22607 Hamburg (Germany); Rueffer, R. [ESRF, Polygone Scientifique Louis Neel, 6, rue Jules Horowitz, 38000 Grenoble (France)

    2011-02-01

    The fast response and the short recovery time of avalanche photodiodes (APDs) in linear mode make those devices ideal for direct X-ray detection in applications requiring high time resolution or counting rate. In order to provide position sensitivity, the XNAP project aims at creating a hybrid pixel detector with nanosecond time resolution based on a monolithic APD sensor array with 32 x32 pixels covering about 1 cm{sup 2} active area. The readout is implemented in a pixelated front-end ASIC suited for the readout of such arrays, matched to pixels of 280{mu}mx280{mu}m size. Every single channel features a fast transimpedance amplifier, a discriminator with locally adjustable threshold and two counters with high dynamic range and counting speed able to accumulate X-ray hits with no readout dead time. Additionally, the detector can be operated in list mode by time-stamping every single event with sub-nanosecond resolution. In a first phase of the project, a 4x4 pixel test module is built to validate the conceptual design of the detector. The XNAP project is briefly presented and the performance of the readout ASIC is discussed.

  3. Broadband ultraviolet-visible transient absorption spectroscopy in the nanosecond to microsecond time domain with sub-nanosecond time resolution.

    Science.gov (United States)

    Lang, Bernhard; Mosquera-Vázquez, Sandra; Lovy, Dominique; Sherin, Peter; Markovic, Vesna; Vauthey, Eric

    2013-07-01

    A combination of sub-nanosecond photoexcitation and femtosecond supercontinuum probing is used to extend femtosecond transient absorption spectroscopy into the nanosecond to microsecond time domain. Employing a passively Q-switched frequency tripled Nd:YAG laser and determining the jitter of the time delay between excitation and probe pulses with a high resolution time delay counter on a single-shot basis leads to a time resolution of 350 ps in picosecond excitation mode. The time overlap of almost an order of magnitude between fs and sub-ns excitation mode permits to extend ultrafast transient absorption (TA) experiments seamlessly into time ranges traditionally covered by laser flash photolysis. The broadband detection scheme eases the identification of intermediate reaction products which may remain undetected in single-wavelength detection flash photolysis arrangements. Single-shot referencing of the supercontinuum probe with two identical spectrometer/CCD arrangements yields an excellent signal-to-noise ratio for the so far investigated chromophores in short to moderate accumulation times.

  4. Temperature field of steel plate cooling process after plate rolling

    Directory of Open Access Journals (Sweden)

    Huijun Feng, Lingen Chen, Fengrui Sun

    2015-01-01

    Full Text Available Based on numerical calculation with Matlab, the study on cooling process after plate rolling is carried out, and the temperature field distribution of the plate varying with the time is obtained. The effects of the plate thickness, final rolling temperature, cooling water temperature, average flow rate of the cooling water, carbon content of the plate and cooling method on the plate surface and central temperatures as well as final cooling temperature are discussed. For the same cooling time, the plate surface and central temperatures as well as their temperature difference increase; with the decrease in rolling temperature and the increase in average flow rate of the cooling water, the plate surface and central temperatures decrease. Compared with the single water cooling process, the temperature difference between the plate centre and surface based on intermittent cooling is lower. In this case, the temperature uniformity of the plate is better, and the corresponding thermal stress is lower. The fitting equation of the final cooling temperature with respect to plate thickness, final rolling temperature, cooling water temperature and average flow rate of the cooling water is obtained.

  5. Sub-nanosecond time resolved light emission study for diffuse discharges in air under steep high voltage pulses

    Science.gov (United States)

    Tardiveau, P.; Magne, L.; Marode, E.; Ouaras, K.; Jeanney, P.; Bournonville, B.

    2016-10-01

    Pin-to-plane discharges in centimetre air gaps and standard conditions of pressure and temperature are generated under very high positive nanosecond scale voltage pulses. The experimental study is based on recordings of sub-nanosecond time resolved and Abel-processed light emission profiles and their complete correlation to electrical current waveforms. The effects of the voltage pulse features (amplitude between 20 and 90 kV, rise time between 2 and 5.2 ns, and time rate between 4 and 40 kV · ns‑1) and the electrode configuration (gap distance between 10 and 30 mm, pin radius between 10 and 200 µm, copper, molybdenum or tungsten pin material) are described. A three time period development can be found: a glow-like structure with monotonic light profiles during the first 1.5 ns whose size depends on time voltage rate, a shell-like structure with bimodal profiles whose duration and extension in space depends on rise time, and either diffuse or multi-channel regime for the connection to the cathode plane according to gap distance. The transition of the light from monotonic to bimodal patterns reveals the relative effects and dynamics of streamer space charge and external laplacian field. A classical 2D-fluid model for streamer propagation has been used and adapted for very high and steep voltage pulses. It shows the formation of a strong space charge (streamer) very close to the pin, but also a continuity of emission between the pin and the streamer, and electric fields higher than the critical ionization field (28 kV · cm‑1 in air) almost in the whole gap and very early in the discharge propagation.

  6. Create Your Plate

    Medline Plus

    Full Text Available ... A A A Listen En Español Create Your Plate Create Your Plate is a simple and effective ... and that your options are endless. Create Your Plate! Click on the plate sections below to add ...

  7. Evaluation of different plating medias and PCR in the detecting of Salmonella Enteritidis from eggs laid by experimentally infected hens

    Directory of Open Access Journals (Sweden)

    M. S. Madadi1

    2012-11-01

    Full Text Available Salmonellosis is one of the most important food-borne diseases. Outbreaks of Salmonellosis are mainly related to the consumption of contaminated eggs or egg-products and, less frequently, of poultry meat. In this study fifty 29-week-old broiler breeder hens were randomly divided in two groups of 25 birds. One group of birds inoculated orally with 10log10 CFU and other group inoculated intravenously with 6log10 CFU of S. Enteritidis parent strain bacteria. During 35 days of experimental period, produced eggs were cultured using different medias and S.Enteritidis was detected using different cultural and PCR method. SE was isolated during 32.5 % of experimental days and more isolation rate of Salmonella was during the first two weeks of post infection period. In contrast, using pre-enrichment media resulted more isolation rate of Salmonella cells and SS agar was more sensitive than BG agar. PCR was more sensitive than cultural methods for detection of Salmonella Enteritidis from contaminated eggs.

  8. License plate detection algorithm

    Science.gov (United States)

    Broitman, Michael; Klopovsky, Yuri; Silinskis, Normunds

    2013-12-01

    A novel algorithm for vehicle license plates localization is proposed. The algorithm is based on pixel intensity transition gradient analysis. Near to 2500 natural-scene gray-level vehicle images of different backgrounds and ambient illumination was tested. The best set of algorithm's parameters produces detection rate up to 0.94. Taking into account abnormal camera location during our tests and therefore geometrical distortion and troubles from trees this result could be considered as passable. Correlation between source data, such as license Plate dimensions and texture, cameras location and others, and parameters of algorithm were also defined.

  9. Dynamic modelling of high biomass density cultivation and biohydrogen production in different scales of flat plate photobioreactors.

    Science.gov (United States)

    Zhang, Dongda; Dechatiwongse, Pongsathorn; Del Rio-Chanona, Ehecatl Antonio; Maitland, Geoffrey C; Hellgardt, Klaus; Vassiliadis, Vassilios S

    2015-12-01

    This paper investigates the scaling-up of cyanobacterial biomass cultivation and biohydrogen production from laboratory to industrial scale. Two main aspects are investigated and presented, which to the best of our knowledge have never been addressed, namely the construction of an accurate dynamic model to simulate cyanobacterial photo-heterotrophic growth and biohydrogen production and the prediction of the maximum biomass and hydrogen production in different scales of photobioreactors. To achieve the current goals, experimental data obtained from a laboratory experimental setup are fitted by a dynamic model. Based on the current model, two key original findings are made in this work. First, it is found that selecting low-chlorophyll mutants is an efficient way to increase both biomass concentration and hydrogen production particularly in a large scale photobioreactor. Second, the current work proposes that the width of industrial scale photobioreactors should not exceed 0.20 m for biomass cultivation and 0.05 m for biohydrogen production, as severe light attenuation can be induced in the reactor beyond this threshold.

  10. Investigating the deformation of upper crustal faults at the N-Chilean convergent plate boundary at different scales using high-resolution topography datasets and creepmeter measurements

    Science.gov (United States)

    Ewiak, O.; Victor, P.; Ziegenhagen, T.; Oncken, O.

    2012-04-01

    The Chilean convergent plate boundary is one of the tectonically most active regions on earth and prone to large megathrust earthquakes as e. g. the 2010 Mw 8.8 Maule earthquake which ruptured a mature seismic gap in south-central Chile. In northern Chile historical data suggests the existence of a seismic gap between Arica and Mejillones Peninsula (MP), which has not ruptured since 1877. Further south, the 1995 Mw 8.0 Antofagasta earthquake ruptured the subduction interface between MP and Taltal. In this study we investigate the deformation at four active upper plate faults (dip-slip and strike-slip) located above the coupling zone of the subduction interface. The target faults (Mejillones Fault - MF, Salar del Carmen Fault - SCF, Cerro Fortuna Fault - CFF, Chomache Fault - CF) are situated in forearc segments, which are in different stages of the megathrust seismic cycle. The main question of this study is how strain is accumulated in the overriding plate, what is the response of the target faults to the megathrust seismic cycle and what are the mechanisms / processes involved. The hyper arid conditions of the Atacama desert and the extremely low erosion rates enable us to investigate geomorphic markers, e .g. fault scarps and knickpoints, which serve as a record for upper crustal deformation and fault activity about ten thousands years into the past. Fault scarp data has been acquired with Differential-GPS by measuring high-resolution topographic profiles perpendicular to the fault scarps and along incised gullies. The topographic data show clear variations between the target faults which possibly result from their position within the forearc. The surveyed faults, e. g. the SCF, exhibit clear along strike variations in the morphology of surface ruptures attributed to seismic events and can be subdivided into individual segments. The data allows us to distinguish single, composite and multiple fault scarps and thus to detect differences in fault growth initiated

  11. An experimental study on single phase convection heat transfer and pressure drop in two brazed plate heat exchangers with different chevron shapes and hydraulic diameters

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Man Bae; Park, Chang Yong [Seoul National University of Science and Technology, Seoul (Korea, Republic of)

    2017-05-15

    An experimental study on heat transfer and pressure drop characteristics was performed at single phase flow in two Brazed plate heat exchangers (BPHEs) with different geometries. The corrugation density of one of the BPHE (Type II) was two times as high as that of the other BPHE (Type I). The hydraulic diameter of the type II BPHE was 2.13 mm, which was 38 % smaller than that of the type I BPHE. Also, the cross section shape of the flow channels for the type II BPHE was different from that for conventional BPHEs due to the unusual corrugation patterns and brazing points. The experimental conditions for temperatures were varied from 4.6 °C to 49.1 °C, and for mass flow rates were changed from 0.07 kg/s to 1.24 kg/s. The measured results showed that pressure drop in the type II BPHE was about 110 % higher than that in the type I BPHE. Nu of the type II was higher than that of the type I BPHE and the enhancement became larger with the increase of Re at the ranges above 800. New correlations for fF and Nu were proposed by this study and their prediction accuracy could be improved by considering the surface enlargement factor in the correlations. The performance evaluation of the two BPHEs was performed by (j/f{sub F}1{sup /3}) which represented the ratio of heat transfer and pressure drop performance. Also, a new parameter, the capacity compactness of PHE, was proposed and it presented the PHE capacity per unit volume and unit log mean temperature difference. The comparison showed that the two BPHEs had similar values of the (j/f{sub F}1{sup /3}), whereas they had significantly different values of the capacity compactness. The capacity compactness of the type II BPHE was 1.5 times higher than that for the type I BPHE.

  12. Plate shell structures of glass

    DEFF Research Database (Denmark)

    Bagger, Anne

    . This modelling technique is used to model a plate shell structure with a span of 11.5 meters in the FE software \\textsc{Abaqus}. The structure is analyzed with six different connection details with varying stiffness characteristics, to investigate the influence of these characteristics on the structural effects...... University, a script has been developed for an automated generation of a given plate shell geometry and a corresponding finite element (FE) model. A suitable FE modelling technique is proposed, suggesting a relatively simple method of modelling the connection detail's stiffness characteristics....... Based on these investigations, and FE analysis of other plate shell models, the structural behaviour is described. Possible methods of estimating the stresses in a given plate shell structure are proposed. The non-linear behaviour of a plate shell structure is investigated for varying parameters...

  13. TNSA ion acceleration at 1016 W/cm2 sub-nanosecond laser intensity

    Science.gov (United States)

    Torrisi, L.; Cutroneo, M.; Calcagno, L.; Rosinski, M.; Ullschmied, J.

    2014-04-01

    Micrometric thin targets have been irradiated in vacuum in TNSA (Target Normal Sheath Acceleration) configuration at PALS Laboratory in Prague by using 1016 W/cm2 laser intensity, 1315 nm wavelength, 300 ps pulse duration and different laser beam energies and focal positions. The plasmas produced were characterized by using ion collectors, semiconductor SiC detectors, X-ray streak camera and Thomson parabola spectrometer. Time of flight techniques, time resolved imaging and ion deflection spectrometry were used to characterize the laser-generated non-equilibrium plasma and the electric field driving ion acceleration developed at the rear side of the target. The maximum ion acceleration can be obtained for optimal film thickness depending on the laser energy and on the kind of irradiated targets. Special targets containing nanostructures, showing high absorption and low reflective coefficients, induce resonant absorption effects enhancing the electric acceleration field. The maximum kinetic energy measured for proton ions was above 5.0 MeV and the ion distributions can be fitted with Coulomb-Boltzmann shifted functions.

  14. Practical automatic Arabic license plate recognition system

    Science.gov (United States)

    Mohammad, Khader; Agaian, Sos; Saleh, Hani

    2011-02-01

    Since 1970's, the need of an automatic license plate recognition system, sometimes referred as Automatic License Plate Recognition system, has been increasing. A license plate recognition system is an automatic system that is able to recognize a license plate number, extracted from image sensors. In specific, Automatic License Plate Recognition systems are being used in conjunction with various transportation systems in application areas such as law enforcement (e.g. speed limit enforcement) and commercial usages such as parking enforcement and automatic toll payment private and public entrances, border control, theft and vandalism control. Vehicle license plate recognition has been intensively studied in many countries. Due to the different types of license plates being used, the requirement of an automatic license plate recognition system is different for each country. [License plate detection using cluster run length smoothing algorithm ].Generally, an automatic license plate localization and recognition system is made up of three modules; license plate localization, character segmentation and optical character recognition modules. This paper presents an Arabic license plate recognition system that is insensitive to character size, font, shape and orientation with extremely high accuracy rate. The proposed system is based on a combination of enhancement, license plate localization, morphological processing, and feature vector extraction using the Haar transform. The performance of the system is fast due to classification of alphabet and numerals based on the license plate organization. Experimental results for license plates of two different Arab countries show an average of 99 % successful license plate localization and recognition in a total of more than 20 different images captured from a complex outdoor environment. The results run times takes less time compared to conventional and many states of art methods.

  15. 猪瘟病毒E2抗原在不同酶标板上包被效果的比较%Comparison of coating capacity of CSFV E2 on different polystyrene plates

    Institute of Scientific and Technical Information of China (English)

    宋艳; 单晶辉; 张茂林; 段铭; 关振宏; 李宁; 卢强; 涂长春

    2011-01-01

    In order to evaluate the affinity property of ELISA plate to baculoviruses-expressed glycoprotein E2 of classical swine fever virus, three commercial ELISA plates, Nunc Maxisorp, Cosar StripWell and JET plates were selected and coated with CSFV E2 antigen at 2 μg/mL. After flyer liquid plate sealer (FLPS) blocking, the highly sensitive plate was screened by CSFV positive pig sera, followed by treatment with other blocking agents, such as PBST (10% FCS) and PBST (1% BSA). The second and third use of FLPS were also evaluated on the selected plates, respectively. The results showed that there were significant differences among the plates (p<0.05), and the most sensitive data was obtained on costar plate, and no significant variations were founded among the used blocking agents (p>0.05).%为比较杆状病毒表达的猪瘟病毒(CSFV)E2抗原在不同酶标板上的包被效果,本研究应用2 Rg/mL的CSFV E2分别包被Nunc Maxisorp,Cosar StripWell和JET FEP-101-896 3种酶标板,以Flyer Liquid Plate Sealer(FLPS)进行封闭,通过比较猪瘟阳性血清的OD_450值,筛选包被性能最佳的酶标板.对FLPS、含10%FCS的PBST和含1 % BSA的PBST的封闭效果进行比较.并比较 FLPS在相同抗原条件下重复使用2次和3次对于CSFV阳性血清检测结果的影响.结果显示,在CSFV E_2抗原包被的3种酶标板上,CSFV阳性血清的OD_450nm,值均存在显著差异(p0.05).

  16. Investigation into the Influence of Post-Weld Heat Treatment on the Friction Stir Welded AA6061 Al-Alloy Plates with Different Temper Conditions

    Science.gov (United States)

    İpekoğlu, Güven; Erim, Seçil; Çam, Gürel

    2014-02-01

    In this study, the effect of post-weld heat treatment (PWHT) on the microstructure and mechanical properties of friction stir butt-joined AA6061 Al-alloy plates both in O and T6-temper conditions was investigated by detailed microstructural investigations and microhardness measurements, in combination with transverse tensile testing. It was determined that the PWHT might result in abnormal grain growth (AGG) in the weld zone particularly in the joints produced in O-temper condition depending on the weld parameters used during friction stir welding. The PWHT generally led to an improvement in the mechanical properties even if AGG took place. Thus, the post-weld heat-treated joints exhibited mechanical properties much higher than those of respective as-welded plates and comparable to those of the respective base plates.

  17. SPORT: A new sub-nanosecond time-resolved instrument to study swift heavy ion-beam induced luminescence - Application to luminescence degradation of a fast plastic scintillator

    CERN Document Server

    Gardés, E; Ban-d'Etat, B; Cassimi, A; Durantel, F; Grygiel, C; Madi, T; Monnet, I; Ramillon, J -M; Ropars, F; Lebius, H

    2013-01-01

    We developed a new sub-nanosecond time-resolved instrument to study the dynamics of UV-visible luminescence under high stopping power heavy ion irradiation. We applied our instrument, called SPORT, on a fast plastic scintillator (BC-400) irradiated with 27-MeV Ar ions having high mean electronic stopping power of 2.6 MeV/\\mu m. As a consequence of increasing permanent radiation damages with increasing ion fluence, our investigations reveal a degradation of scintillation intensity together with, thanks to the time-resolved measurement, a decrease in the decay constant of the scintillator. This combination indicates that luminescence degradation processes by both dynamic and static quenching, the latter mechanism being predominant. Under such high density excitation, the scintillation deterioration of BC-400 is significantly enhanced compared to that observed in previous investigations, mainly performed using light ions. The observed non-linear behaviour implies that the dose at which luminescence starts deteri...

  18. Theoretical and experimental study of superradiance pulse generation by heavy-current subnanosecond electron bunches moving in periodic slowing down system

    CERN Document Server

    Ginzburg, N S; Novozhilova, Y V; Sergeev, A S; Shpak, V G; Shunailov, S A; Ul'maskulov, M R; Yalandin, M I

    2002-01-01

    One studied both theoretically and experimentally the Cherenkov superradiance at liner motion of an electron bunch through the periodic slowing down system. Simulations in terms of the KARAT code show that peak intensity of microwave pulses is proportional to the square of total number of particles in a bunch. This finding os conformed experimentally. As a results, at 39 GHz frequency one obtained ultrashort pulses of up to 140 MW high intensity and with 30 ps duration. The RADAN 303 high-current subnanosecond accelerator injected electron bunches with up to 2 A current, 0.5-1.5 ns duration and 200-300 keV particle energy was used as a source of electrons. Simulation shows possibility of further intensification of electromagnetic pulses up to 300-400 MW due to optimization of parameters of accelerating voltage pulse

  19. Performance enhancement of sub-nanosecond diode-pumped passively Q-switched Yb:YAG microchip laser with diamond surface cooling.

    Science.gov (United States)

    Zhuang, W Z; Chen, Yi-Fan; Su, K W; Huang, K F; Chen, Y F

    2012-09-24

    We experimentally confirm that diamond surface cooling can significantly enhance the output performance of a sub-nanosecond diode-end-pumped passively Q-switched Yb:YAG laser. It is found that the pulse energy obtained with diamond cooling is approximately 1.5 times greater than that obtained without diamond cooling, where a Cr(4+):YAG absorber with the initial transmission of 84% is employed. Furthermore, the standard deviation of the pulse amplitude peak-to-peak fluctuation is found to be approximately 3 times lower than that measured without diamond cooling. Under a pump power of 3.9 W, the passively Q-switched Yb:YAG laser can generate a pulse train of 3.3 kHz repetition rate with a pulse energy of 287 μJ and with a pulse width of 650 ps.

  20. Subnanosecond Scintillation Detector

    Science.gov (United States)

    Hoenk, Michael (Inventor); Hennessy, John (Inventor); Hitlin, David (Inventor)

    2017-01-01

    A scintillation detector, including a scintillator that emits scintillation; a semiconductor photodetector having a surface area for receiving the scintillation, wherein the surface area has a passivation layer configured to provide a peak quantum efficiency greater than 40% for a first component of the scintillation, and the semiconductor photodetector has built in gain through avalanche multiplication; a coating on the surface area, wherein the coating acts as a bandpass filter that transmits light within a range of wavelengths corresponding to the first component of the scintillation and suppresses transmission of light with wavelengths outside said range of wavelengths; and wherein the surface area, the passivation layer, and the coating are controlled to increase the temporal resolution of the semiconductor photodetector.

  1. Relations between plate kinematics, slab geometry and overriding plate deformation in subduction zones: insights from statistical observations and laboratory modelling

    Science.gov (United States)

    Heuret, A.; Funiciello, F.; Faccenna, C.; Lallemand, S.

    2005-12-01

    3-D laboratory models have been performed in order to investigate the way plates kinematics (subducting and overriding plate absolute motions and the resulting plate convergence rate) influences the geometry of the slab and the overriding plate deformation in subduction zones. In the experiments a viscous plate of silicone (subducting plate) is pushed beneath another plate, which is itself pushed toward or pulled away from the trench (overriding plate), and sinks into a viscous layer of glucose syrup (upper mantle). The subducting and overriding plate velocities explored the variability field of natural subduction plates kinematics. The overriding plate motion exerts a primary role in the control of slab geometries and overriding plate deformation rates. The experiments have revealed two different subduction behaviours: (Style I) the overriding plate moves toward the trench and shortens at high rates, the slab is flat and deflected when reaching the bottom of the box in a forward direction; (Style II) the overriding plates moves away from the trench and shortens at low rates the slab is steep and deflected on the box bottom in a backward direction. To a lesser extent, increasing subducting plate motion is associated to increasing slab dips and overriding plate shortening. Slab geometry and overriding plate deformation are less sensitive to the overall plate convergence rate. These laboratory models behaviours are consistent with statistical analysis performed on natural subduction zones, and enlighten the first order control exerted by the overriding plate absolute motion, on the geometry adopted by the slab and the way the overriding plate deforms.

  2. Do different standard plate counting (IDF/ISSO or AOAC) methods interfere in the conversion of individual bacteria counts to colony forming units in raw milk?

    Science.gov (United States)

    Cassoli, L D; Lima, W J F; Esguerra, J C; Da Silva, J; Machado, P F; Mourão, G B

    2016-10-01

    This study aimed to establish the correlation between individual bacterial count (IBC) obtained by flow cytometry and the number of colony forming units (CFU) determined by standard plate count (SPC) in raw milk using two different reference methodologies: the methodology of the International Dairy Federation (IDF) - International Organization for Standardization (ISO) 4833, incubation for 72 h at 30°C and the methodology of the Association of Official Analytical Chemists (AOAC), incubation for 48 h at 35°C. For this, 100 bovine milk samples (80 ml) from different farms were collected in a sterile bottle and maintained refrigerated at 4°C and were delivered to the laboratory. In the laboratory, the samples were divided into two vials of 40 ml each. Then, half of the vials were forwarded for the SPC analysis, and the other half were analysed using the equipment BactoScan FC. The analyses by flow cytometry and SPC were performed at the same time (maximum deviation of +/- 1 h). To transform the data from IBC ml(-1) to CFU ml(-1) (IDF or AOAC methodology), a standard linear regression equation was used, as recommended by IDF/ISO-196. The difference between the reference methodologies affects the equation that transforms IBC into CFU and therefore the accuracy of the results. The results estimated by the equation using the ISO 4833 methodology were on average 0·18 log units higher than the results estimated using the equation using the AOAC methodology. After the comparison of the methodologies, it was concluded that there is an impact of the reference methodologies on the conversion of the results from IBC to CFU. Depending on the methodology adopted by each laboratory or country, there may not be equivalence in the results. Hence, the laboratories specialized in milk quality analysis that have changed their methodology for analysis, passing from the MAPA (AOAC) methodology to the IDF standard, need to develop new conversion equations to make their

  3. Rhodium platings – experimental study

    Directory of Open Access Journals (Sweden)

    R. Rudolf

    2013-07-01

    Full Text Available Modern rhodium plating solutions are based on either sulphate or phosphate. Although in theory there are four possible combinations, in practice only three different rhodium electrolytes are used. These are based on dilutions of rhodium sulphate or phosphate concentrates with added sulphuric or phosphoric acid. These processes are be discussed in this paper with a demonstration of Rh platings in the Slovenian firm Zlatarna Celje d.d.

  4. The concept of locking plates.

    Science.gov (United States)

    Cronier, P; Pietu, G; Dujardin, C; Bigorre, N; Ducellier, F; Gerard, R

    2010-05-01

    After a short historical review of locking bone plates since their inception more than a century ago to the success of the concept less than 15 years ago with today's plates, the authors present the main locking mechanisms in use. In the two broad categories - plates with fixed angulation and those with variable angulation - the screw head is locked in the plate with a locknut by screwing in a threaded chamber on the plate or by screwing through an adapted ring. The authors then provide a concrete explanation, based on simple mechanical models, of the fundamental differences between conventional bone plates and locking plates and why a locking screw system presents greater resistance at disassembly, detailing the role played by the position and number of screws. The advantages of epiphyseal fixation are then discussed, including in cases of mediocre-quality bone. For teaching purposes, the authors also present assembly with an apple fixed with five locking screws withstanding a 47-kg axial load with no resulting disassembly. The principles of plate placement are detailed for both the epiphysis and diaphysis, including the number and position of screws and respect of the soft tissues, with the greatest success assured by the minimally invasive and even percutaneous techniques. The authors then present the advantages of locking plates in fixation of periprosthetic fractures where conventional osteosynthesis often encounters limited success. Based on simplified theoretical cases, the economic impact in France of this type of implant is discussed, showing that on average it accounts for less than 10% of the overall cost of this pathology to society. Finally, the possible problems of material ablation are discussed as well as the means to remediate these problems.

  5. Far-Field Deformation Resulting from Rheologic Differences Interacting with Tectonic Stresses: An Example from the Pacific/Australian Plate Boundary in Southern New Zealand

    Directory of Open Access Journals (Sweden)

    Phaedra Upton

    2014-07-01

    Full Text Available The Miocene in Southern New Zealand was dominated by strike-slip tectonics. Stratigraphic evidence from this time attests to two zones of subsidence in the south: (a a middle Cenozoic pull-apart basin and (b a regionally extensive subsiding lake complex, which developed east and distal to the developing plate boundary structure. The lake overlay a block of crust with a significantly weak mid-crustal section and we pose the question: can rheological transitions at an angle to a plate boundary produce distal subsidence and/or uplift? We use stratigraphic, structural and geophysical observations from Southern New Zealand to constrain three-dimensional numerical models for a variety of boundary conditions and rheological scenarios. We show that coincident subsidence and uplift can result from purely strike-slip boundary conditions interacting with a transition from strong to weak to strong mid-crustal rheology. The resulting pattern of vertical displacement is a function of the symmetry or asymmetry of the boundary conditions and the extent and orientation of the rheological transitions. For the Southern New Zealand case study, subsidence rates of ~0.1 mm/yr are predicted for a relative plate motion of 25 mm/yr, leading to ~500 m of subsidence over a 5 Ma time period, comparable to the thickness of preserved lacustrine sediments.

  6. Hierarchical self-organization of tectonic plates

    CERN Document Server

    Morra, Gabriele; Müller, R Dietmar

    2010-01-01

    The Earth's surface is subdivided into eight large tectonic plates and many smaller ones. We reconstruct the plate tessellation history and demonstrate that both large and small plates display two distinct hierarchical patterns, described by different power-law size-relationships. While small plates display little organisational change through time, the structure of the large plates oscillate between minimum and maximum hierarchical tessellations. The organization of large plates rapidly changes from a weak hierarchy at 120-100 million years ago (Ma) towards a strong hierarchy, which peaked at 65-50, Ma subsequently relaxing back towards a minimum hierarchical structure. We suggest that this fluctuation reflects an alternation between top and bottom driven plate tectonics, revealing a previously undiscovered tectonic cyclicity at a timescale of 100 million years.

  7. Create Your Plate

    Medline Plus

    Full Text Available ... steps to get started: Using your dinner plate, put a line down the middle of the plate. ... vegetables . Now in one of the small sections, put grains and starchy foods. See this list of ...

  8. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate It's simple and effective for both managing diabetes and losing weight. Creating your plate lets ... 2016 Articles from Diabetes Forecast® magazine: wcie-meal-planning, In this section Food Planning Meals Diabetes Meal ...

  9. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal ... Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook ...

  10. Food guide plate

    Science.gov (United States)

    ... chips or cookies. VEGETABLES: MAKE HALF OF YOUR PLATE FRUITS AND VEGETABLES Vegetables can be raw, fresh, ... as a snack. FRUITS: MAKE HALF OF YOUR PLATE FRUITS AND VEGETABLES Fruits can be fresh, canned, ...

  11. Growth Plate Fractures

    Science.gov (United States)

    ... the most widely used by doctors is the Salter-Harris system, described below. Type I Fractures These ... incidence of growth plate fractures peaks in adolescence. Salter-Harris classification of growth plate fractures. AAOS does ...

  12. Create Your Plate

    Medline Plus

    Full Text Available ... Planning Meals Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook ... Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart- ...

  13. Create Your Plate

    Medline Plus

    Full Text Available ... Planning Meals Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook ... Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart- ...

  14. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate It's simple and effective for both managing diabetes and losing weight. Creating your plate lets you still choose the foods you want, but changes the portion sizes so you are getting larger ...

  15. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate It's simple and effective for both managing diabetes and losing weight. Creating your plate lets ... Sleeve Custom jerseys for your Tour de Cure team benefits the cause. Ask the Experts: Learn to ...

  16. 不同来流下薄平板流固耦合特性分析%Fluid-structure Interaction for Thin Plate With Different Flow Parameters

    Institute of Scientific and Technical Information of China (English)

    吕坤; 张荻; 谢永慧

    2011-01-01

    The study of fluid-structure interaction of thin plate has broad applications in nuclear reactor fuel assembly and the wind turbine blade. Fluid-structure interaction analysis was based on the interaction between unsteady flow and the thin plate's vibration. The characteristics of the plate's vibration and the unsteady flow behaviors around the plate were obtained. Results reveal that under the impact of stable flow, the thin plate vibrates at its first-order natural frequency and the vibration is self-excited vibration. At the same angle of attack, fluid-structure interaction becomes more severe with the increase of flow velocity. The comparison between the results without considering fluid-structure interaction and the results considering fluid-structure interaction was made. The comparison results show that the average aerodynamic force is larger without the consideration of fluid-structure interaction. The vibration of the thin plate restrains the formation of eddies. It can also remain the plate's attached flow and delay the flow separation.%薄平板的流固耦合特性研究在核反应堆板状燃料组件和风力透平叶片等方面具有广泛的应用背景。基于非定常流动和弹性薄平板振动理论建立了薄平板的流固耦合特性研究模型,并得到了平板的振动特性以及平板周围流场的非定常流动特性。结果表明:平板在持续稳定的来流冲击下,主要以其一阶固有频率产生振动,平板的振动属于自激振动;相同攻角条件下,流固耦合现象随流速的增加而更加剧烈。对比平板在相同来流下考虑和不考虑流固耦合的分析结果表明:不考虑耦合时作用在板上的持续平均气动力大于考虑耦合时的情况;流固耦合过程中,平板振动对涡的形成产生抑制,保持平板的附着流,延迟分离。

  17. Accelerated plate tectonics.

    Science.gov (United States)

    Anderson, D L

    1975-03-21

    The concept of a stressed elastic lithospheric plate riding on a viscous asthenosphere is used to calculate the recurrence interval of great earthquakes at convergent plate boundaries, the separation of decoupling and lithospheric earthquakes, and the migration pattern of large earthquakes along an arc. It is proposed that plate motions accelerate after great decoupling earthquakes and that most of the observed plate motions occur during short periods of time, separated by periods of relative quiescence.

  18. Sigmoid plate dehiscence: Congenital or acquired condition?

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Zhaohui, E-mail: lzhtrhos@163.com [Capital Medical University, Beijing Tongren Hospital, No 1 Dong Jiao Min Street, Dongcheng District, Beijing 100730 (China); Li, Jing, E-mail: lijingxbh@yahoo.com.cn [Capital Medical University, Beijing Tongren Hospital, No 1 Dong Jiao Min Street, Dongcheng District, Beijing 100730 (China); Zhao, Pengfei, E-mail: zhaopengf05@163.com [Capital Medical University, Beijing Friendship Hospital, No 95 Yongan Road, Xicheng District, Beijing 100050 (China); Lv, Han, E-mail: chrislvhan@126.com [Capital Medical University, Beijing Friendship Hospital, No 95 Yongan Road, Xicheng District, Beijing 100050 (China); Dong, Cheng, E-mail: derc007@sina.com [Capital Medical University, Beijing Friendship Hospital, No 95 Yongan Road, Xicheng District, Beijing 100050 (China); Liu, Wenjuan, E-mail: wenjuanliu@163.com [Jining No. 1 People' s Hospital, No. 6 Health Street, Jining 272100 (China); Wang, Zhenchang, E-mail: cjr.wzhch@vip.163.com [Capital Medical University, Beijing Friendship Hospital, No 95 Yongan Road, Xicheng District, Beijing 100050 (China)

    2015-05-15

    Highlights: • CT with multiplanar reformations can accurately display the sigmoid platet dehiscence. • The prevalence of sigmoid plate dehiscence was no significant difference among different age groups. • The size of sigmoid plate bony defects were not statistically different among different age groups. • The sigmoid plate dehiscence is more commonly a congenital than an acquired condition. - Abstract: Background and purpose: The imaging features of sigmoid plate dehiscence-induced pulsatile tinnitus have been presented. The origin of the sigmoid plate dehiscence, however, remains unclear. Our aim was to assess the prevalence and extent of sigmoid plate dehiscence on computed tomography (CT) images in multiple age groups to determine whether this condition is more likely to be congenital or acquired. Materials and methods: We retrospectively reviewed contrast-enhanced CT images of sigmoid plates of temporal bones in 504 patients. Each temporal bone was characterized as normal or dehiscent. Patients were then subcategorized into four age groups, and the prevalence and extent of dehiscent sigmoid plates in each group were calculated and compared. Results: Overall, 80 patients had sigmoid plate dehiscence, nine of whom had it bilaterally. In successively older age groups, the prevalences of sigmoid plate dehiscence were 18.9%, 20.1%, 14.5%, and 12.7%, respectively. Respective average anteroposterior bony defect diameters were 3.7 ± 1.7, 3.0 ± 1.3, 3.1 ± 1.5, and 3.0 ± 1.1 mm. Respective average vertical bony defect diameters were 3.6 ± 2.3, 2.6 ± 1.2, 3.2 ± 1.5, and 3.0 ± 1.7 mm. The prevalence and extent of sigmoid plate dehiscence were not statistically different among the four age groups. Conclusions: The similar radiologic prevalence and extent of dehiscent sigmoid plates among the age groups suggest that the dehiscence is more commonly a congenital than an acquired condition.

  19. Expression of the difference between the Cold(Han) and Hot(Re) natures of traditional Chinese medicines(Strobal and Rhubarb) based on the cold/hot plate differentiating assay

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    In this study, objective differences between the Cold (Han) and Hot (Re) nature of traditional Chinese medicines, e.g. Strobal and Rhubarb, are determined by using a cold/hot plate differentiation technology. A novel, self-designed cold/hot plate differentiating instrument, with methodological study, was used to investigate the intervention of Strobal and Rhubarb on the temperature tropism of mice. Compared with the ICR and BALB/c mice, it was found that KM mice on the cold/hot plate were more sensitive to the change of temperature, within the tolerant temperature range of 15-40 ℃ . The temperature tropism behavior of mice is influenced by treatment with Rhubarb and Strobal, as is the activity of ATPase in liver tissue. These trends are consistent with the definition of the Cold/Hot nature of Chinese medicines based on traditional Chinese medicinal theory. This study showed that the differences of the Cold/Hot nature of traditional Chinese medicines. might be objectively represented by the temperature tropism of animal by means of cold/hot differentiating assay.

  20. Create Your Plate

    Medline Plus

    Full Text Available ... Reset Plate Share Create Your Plate ! Share: Seven Simple Steps to Create Your Plate It's simple and effective for both managing diabetes and losing ... en.html Have Type 2 Diabetes? Our free program will help you live well. More from diabetes. ...

  1. Obliquity along plate boundaries

    Science.gov (United States)

    Philippon, Mélody; Corti, Giacomo

    2016-12-01

    Most of the plate boundaries are activated obliquely with respect to the direction of far field stresses, as roughly only 8% of the plate boundaries total length shows a very low obliquity (ranging from 0 to 10°, sub-orthogonal to the plate displacement). The obliquity along plate boundaries is controlled by (i) lateral rheological variations within the lithosphere and (ii) consistency with the global plate circuit. Indeed, plate tectonics and magmatism drive rheological changes within the lithosphere and consequently influence strain localization. Geodynamical evolution controls large-scale mantle convection and plate formation, consumption, and re-organization, thus triggering plate kinematics variations, and the adjustment and re-orientation of far field stresses. These geological processes may thus result in plate boundaries that are not perpendicular but oblique to the direction of far field stresses. This paper reviews the global patterns of obliquity along plate boundaries. Using GPlate, we provide a statistical analysis of present-day obliquity along plate boundaries. Within this framework, by comparing natural examples and geological models, we discuss deformation patterns and kinematics recorded along oblique plate boundaries.

  2. The NH2-terminal and COOH-terminal fragments of dentin matrix protein 1 (DMP1) localize differently in the compartments of dentin and growth plate of bone.

    Science.gov (United States)

    Maciejewska, Izabela; Cowan, Cameron; Svoboda, Kathy; Butler, William T; D'Souza, Rena; Qin, Chunlin

    2009-02-01

    Multiple studies have shown that dentin matrix protein 1 (DMP1) is essential for bone and dentin mineralization. After post-translational proteolytic cleavage, DMP1 exists within the extracellular matrix of bone and dentin as an NH2-terminal fragment, a COOH-terminal fragment, and the proteoglycan form of the NH2-terminal fragment (DMP1-PG). To begin to assess the biological function of each fragment, we evaluated the distribution of both fragments in the rat tooth and bone using antibodies specific to the NH2-terminal and COOH-terminal regions of DMP1 and confocal microscopy. In rat first molar organs, the NH2-terminal fragment localized to predentin, whereas the COOH-terminal fragment was mainly restricted to mineralized dentin. In the growth plate of bone, the NH2-terminal fragment appeared in the proliferation and hypertrophic zones, whereas the COOH-terminal fragment occupied the ossification zone. Forster resonance energy transfer analysis showed colocalization of both fragments of DMP1 in odontoblasts and predentin, as well as hypertrophic chondrocytes within the growth plates of bone. The biochemical analysis of bovine teeth showed that predentin is rich in DMP1-PG, whereas mineralized dentin primarily contains the COOH-terminal fragment. We conclude that the differential patterns of expression of NH2-terminal and COOH-terminal fragments of DMP1 reflect their potentially distinct roles in the biomineralization of dentin and bone matrices.

  3. High performance flat plate solar collector

    Science.gov (United States)

    Lansing, F. L.; Reynolds, R.

    1976-01-01

    The potential use of porous construction is presented to achieve efficient heat removal from a power producing solid and is applied to solar air heaters. Analytical solutions are given for the temperature distribution within a gas-cooled porous flat plate having its surface exposed to the sun's energy. The extracted thermal energy is calculated for two different types of plate transparency. Results show the great improvement in performance obtained with porous flat plate collectors as compared with analogous nonporous types.

  4. Ultimately Thin Metasurface Wave Plates

    CERN Document Server

    Keene, David; Durach, Maxim

    2015-01-01

    Optical properties of a metasurface which can be considered a monolayer of two classical uniaxial metamaterials, parallel-plate and nanorod arrays, are investigated. It is shown that such metasurface acts as an ultimately thin sub-50 nm wave plate. This is achieved via an interplay of epsilon-near-zero and epsilon-near-pole behavior along different axes in the plane of the metasurface allowing for extremely rapid phase difference accumulation in very thin metasurface layers. These effects are shown to not be disrupted by non-locality and can be applied to the design of ultrathin wave plates, Pancharatnam-Berry phase optical elements and plasmon-carrying optical torque wrench devices.

  5. Angular shear plate

    Science.gov (United States)

    Ruda, Mitchell C [Tucson, AZ; Greynolds, Alan W [Tucson, AZ; Stuhlinger, Tilman W [Tucson, AZ

    2009-07-14

    One or more disc-shaped angular shear plates each include a region thereon having a thickness that varies with a nonlinear function. For the case of two such shear plates, they are positioned in a facing relationship and rotated relative to each other. Light passing through the variable thickness regions in the angular plates is refracted. By properly timing the relative rotation of the plates and by the use of an appropriate polynomial function for the thickness of the shear plate, light passing therethrough can be focused at variable positions.

  6. In-beam measurements of sub-nanosecond nuclear lifetimes with a mixed array of HPGe and LaBr{sub 3}:Ce detectors

    Energy Technology Data Exchange (ETDEWEB)

    Marginean, N.; Bucurescu, D.; Cata-Danil, G.; Cata-Danil, I.; Deleanu, D.; Filipescu, D.; Ghita, D.; Glodariu, T.; Ivascu, M.; Mihai, C.; Marginean, R.; Negret, A.; Pascu, S.; Sava, T.; Stroe, L.; Suliman, G.; Zamfir, N.V. [Horia Hulubei National Institute of Physics and Nuclear Engineering (IFIN-HH), Bucharest (Romania); Balabanski, D.L.; Atanasova, L.; Detistov, P. [Bulgarian Academy of Sciences, Institute for Nuclear Research and Nuclear Energy (INRNE), Sofia (Bulgaria); Lalkovski, S.; Deyanova, G.; Gladnishki, K.A.; Kisyov, S.; Radulov, D. [St. Kliment Ohridski University, Sofia (Bulgaria); Daugas, J.M. [CEA, DAM, DIF, Arpajon (France); Georgiev, G.; Lozeva, R. [CSNSM, Orsay (France)

    2010-12-15

    A fast-timing method to determine lifetimes of nuclear states in the sub-nanosecond domain is presented. It is based on in-beam measurements of triple-gamma coincidences in heavy-ion fusion-evaporation reactions, performed with an array of HPGe and LaBr{sub 3}:Ce detectors. The high-energy resolution HPGe detectors are used to define de-exciting cascades, while the fast LaBr{sub 3}:Ce detectors are used to determine the decay time spectra of selected levels fed by these cascades. A special method to treat the time information of an array of fast detectors is employed in order to fully use the efficiency of the array. Two measurements are presented to illustrate the method: a re-determination of the known half-life T{sub 1/2}=0.7 ns of the E{sub x}=205 keV, J{sup {pi}}=7/2{sup +} level in {sup 107}Cd (test experiment), and the determination of a half-life T{sub 1/2}=47 ps for the E{sub x}=367 keV, J{sup {pi}}=3/2{sup +} state of {sup 199}Tl. (orig.)

  7. Sub-nanosecond periodically poled lithium niobate optical parametric generator and amplifier pumped by an actively Q-switched diode-pumped Nd:YAG microlaser

    Science.gov (United States)

    Liu, L.; Wang, H. Y.; Ning, Y.; Shen, C.; Si, L.; Yang, Y.; Bao, Q. L.; Ren, G.

    2017-05-01

    A sub-nanosecond seeded optical parametric generator (OPG) based on magnesium oxide-doped periodically poled lithium niobate (MgO:PPLN) crystal is presented. Pumped by an actively Q-switched diode-pumped 1 kHz, 1064 nm, Nd:YAG microlaser and seeded with a low power distributed feedback (DFB) diode continuous-wave (CW) laser, the OPG generated an output energy of 41.4 µJ and 681 ps pulse duration for the signal at 1652.4 nm, achieving a quantum conversion efficiency of 61.2% and a slope efficiency of 41.8%. Signal tuning was achieved from 1651.0 to 1652.4 nm by tuning the seed-laser current. The FWHM of the signal spectrum was approximately from 35 nm to 0.5 nm by injection seed laser. The SHG doubled the frequency of OPG signal to produce a output energy of 12 µJ with the energy conversion efficiency of 29.0% and tunanble wavelength near 826 nm.

  8. SPORT: A new sub-nanosecond time-resolved instrument to study swift heavy ion-beam induced luminescence - Application to luminescence degradation of a fast plastic scintillator

    Science.gov (United States)

    Gardés, E.; Balanzat, E.; Ban-d'Etat, B.; Cassimi, A.; Durantel, F.; Grygiel, C.; Madi, T.; Monnet, I.; Ramillon, J.-M.; Ropars, F.; Lebius, H.

    2013-02-01

    We developed a new sub-nanosecond time-resolved instrument to study the dynamics of UV-visible luminescence under high stopping power heavy ion irradiation. We applied our instrument, called SPORT, on a fast plastic scintillator (BC-400) irradiated with 27-MeV Ar ions having high mean electronic stopping power of 2.6 MeV/μm. As a consequence of increasing permanent radiation damages with increasing ion fluence, our investigations reveal a degradation of scintillation intensity together with, thanks to the time-resolved measurement, a decrease in the decay constant of the scintillator. This combination indicates that luminescence degradation processes by both dynamic and static quenching, the latter mechanism being predominant. Under such high density excitation, the scintillation deterioration of BC-400 is significantly enhanced compared to that observed in previous investigations, mainly performed using light ions. The observed non-linear behaviour implies that the dose at which luminescence starts deteriorating is not independent on particles' stopping power, thus illustrating that the radiation hardness of plastic scintillators can be strongly weakened under high excitation density in heavy ion environments.

  9. Detection of artificial occlusal caries in a phosphor imaging plate system with two types of LCD monitors versus three different films.

    Science.gov (United States)

    Ilgüy, Mehmet; Dinçer, Semanur; Ilgüy, Dilhan; Bayirli, Gündüz

    2009-06-01

    The aim of this study was to determine diagnostic performance of a storage phosphor plate system Digora Optime (Soredex, Helsinki, Finland) with two types of LCD monitor in the detection of artificial caries when compared to Ultraspeed (D), Ektaspeed Plus (E), and Insight (F) radiographic films. Seventy extracted human molars-with artificial caries-were radiographed under identical standardized conditions using (1) a storage phosphor plate system Digora (Soredex, Helsinki, Finland), (2) Insight, (3) Ektaspeed Plus, and (4) Ultraspeed (Carestream Health Inc, Rochester, NY). All digital images and radiographs were examined by three observers for the presence or absence of artificial caries using a five-point confidence scale. Digital images were evaluated both on a LCD computer monitor (Philips 170S, Holland) and medical monitor-3 megapixel monochrome display (Me355i2, Totoku, Tokyo)-with brightness and contrast enhancement. Observer responses were evaluated using ROC analysis and other measurements for diagnostic accuracy. Storage phosphor images with medical monitor demonstrated higher mean A (z) values (0.70 +/- 0.08) than digital images with computer monitor and conventional films. Storage phosphor images with medical monitor presented the highest score, 0.97, 0.90, 0.94, for each observer, respectively. Also, true positive observations (0.82) and positive likelihood ratios (2.71) were higher in enhanced storage phosphor images with medical monitor. Caries detection of mechanically created lesions by experienced radiologists is roughly comparable when examining D-speed film images and Digora images on both the computer and medical LCD monitors, and appears to be poorer on E- and F-speed film images.

  10. Coupling between plate vibration and acoustic radiation

    Science.gov (United States)

    Frendi, Abdelkader; Maestrello, Lucio; Bayliss, Alvin

    1993-01-01

    A detailed numerical investigation of the coupling between the vibration of a flexible plate and the acoustic radiation is performed. The nonlinear Euler equations are used to describe the acoustic fluid while the nonlinear plate equation is used to describe the plate vibration. Linear, nonlinear, and quasi-periodic or chaotic vibrations and the resultant acoustic radiation are analyzed. We find that for the linear plate response, acoustic coupling is negligible. However, for the nonlinear and chaotic responses, acoustic coupling has a significant effect on the vibration level as the loading increases. The radiated pressure from a plate undergoing nonlinear or chaotic vibrations is found to propagate nonlinearly into the far field. However, the nonlinearity due to wave propagation is much weaker than that due to the plate vibrations. As the acoustic wave propagates into the far field, the relative difference in level between the fundamental and its harmonics and subharmonics decreases with distance.

  11. Chladni's law for vibrating plates

    Science.gov (United States)

    Rossing, Thomas D.

    1982-03-01

    The normal vibrational modes of free circular plates can be classified according to the number of nodal diameters m and the number of nodal circles n. Chladni observed that the addition of one nodal circle raised the frequency f about the same amount as adding two nodal diameters, and Rayleigh pointed out that f is proportional to (m+2n)2 for large f. Waller, however, concluded that the number of nodal diameters necessary to raise the frequency as much as a nodal circle varies from two to five. We have examined data on the vibrations of flat and non-flat circular plates and fitted their vibration frequencies to the relationship f = c(m+bn)k. By proper choice of c it is possible to satisfy Chladni's law (b = 2, k = 2) over quite a wide range of frequency in flat plates. Non-flat plates such as cymbals and bells, require different choices of b and k. A brief history of Chladni patterns, and suggestions for observing and demonstrating the vibrational modes of plates are included (AIP).

  12. Collaborative study comparing the spiral plate and aerobic plate count methods.

    Science.gov (United States)

    Gilchrist, J E; Donnelly, C B; Peeler, J T; Campbell, J E

    1977-07-01

    The spiral plate count method is a semiautomated plating technique that greatly reduces manpower and material costs normally associated with the pour plating technique. In this collaborative study, 8 laboratories compared the spiral and pour plating techniques, using 4 samples each of 3 products: frozen pumpkin pie, frozen chicken pot pie, and shampoo. The results show that 10 of the 12 comparisons of means of the pour and spiral methods were not significantly different; 2 values were significant at alpha = 0.01. Overall, the components of variance were less than that of the current milk standard, and the replicate per cent coefficient of variation was satisfactory. This study indicates that the spiral plate method is an acceptable alternative to the pour plate method; the spiral plate method has been adopted as official first action.

  13. High-speed microstrip multi-anode multichannel plate detector system

    Science.gov (United States)

    Riedo, Andreas; Tulej, Marek; Rohner, Urs; Wurz, Peter

    2017-04-01

    High-speed detector systems with high dynamic range and pulse width characteristics in the sub-nanosecond regime are mandatory for high resolution and highly sensitive time-of-flight mass spectrometers. Typically, for a reasonable detector area, an impedance-matched anode design is necessary to transmit the registered signal fast and distortion-free from the anode to the signal acquisition system. In this report, a high-speed microstrip multi-anode multichannel plate detector is presented and discussed. The anode consists of four separate active concentric anode segments allowing a simultaneous readout of signal with a dynamic range of about eight orders of magnitude. The impedance matched anode segments show pulse width of about 250 ps, measured at full width at half maximum, and rise time of ˜170 ps, measured with an oscilloscope with a sampling rate of 20 GS/s and 4 GHz analogue bandwidth. The usage of multichannel plates as signal amplifier allowed the design of a lightweight, low power consuming, and compact detector system, suitable, e.g., for the integration into space instrumentation or portable systems where size, weight, and power consumption are limited parameters.

  14. Using plate mapping to examine sensitivity to plate size in food portions and meal composition among college students.

    Science.gov (United States)

    Sharp, David; Sobal, Jeffery

    2012-12-01

    People eat meals rather than nutrients or food groups. Plate size may influence meal size, meal composition, and food type. To examine effects of plate size on meals, we developed a method we label plate mapping. A quasi-experimental study asked university students to accurately draw what they would like to eat for dinner on either a 9″ or 11″ paper plate. Coding plate drawings for total meal size revealed that students drew an average of 26% more food on larger plates. When plates were coded for meal composition we found that the biggest three food portions drawn by students were bigger on 11″ plates, with 70% of the overall difference in food area occurring in the biggest food. Participants drew bigger portions of vegetables on larger plates, while other food types showed little change in mean size. Gender moderated plate sensitivity for food types: women drew 36% bigger vegetable portions than men on larger plates. Smaller plates may lead to smaller meal sizes, but plate size may differentially influence composition of meals for men and women. These findings suggest plate mapping can be used to reflect meal conceptualizations and assess sensitivity to plate size. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Precision Plate Plan View Pattern Predictive Model

    Institute of Scientific and Technical Information of China (English)

    ZHAO Yang; YANG Quan; HE An-rui; WANG Xiao-chen; ZHANG Yun

    2011-01-01

    According to the rolling features of plate mill, a 3D elastic-plastic FEM (finite element model) based on full restart method of ANSYS/LS-DYNA was established to study the inhomogeneous plastic deformation of multipass plate rolling. By analyzing the simulation results, the difference of head and tail ends predictive models was found and modified. According to the numerical simulation results of 120 different kinds of conditions, precision plate plan view pattern predictive model was established. Based on these models, the sizing MAS (mizushima automatic plan view pattern control system) method was designed and used on a 2 800 mm plate mill. Comparing the rolled plates with and without PVPP (plan view pattern predictive) model, the reduced width deviation indicates that the olate !olan view Dattern predictive model is preeise.

  16. Stability of Three-Layered Annular Plate with Composite Facings

    Science.gov (United States)

    Pawlus, D.

    2017-02-01

    Paper presents the behaviour of three-layered annular plates subjected to loads acting in plate plane. Plates are composed of laminated fibre-reinforced composite facings and foam core. The static and dynamic parameters of plate critical state were evaluated. The sensitivity of composite structure of plate to the acting of quickly increasing in time loads is shown. The problem has been solved numerically using the finite element method. Results have been compared with ones obtained for plate models with isotropic layers. These plate models have also been calculated solving formulated task analytically and numerically by means of the finite difference method. Solutions to the problem concern the axisymmetrical and asymmetrical plate buckling modes. Numerous presented tables and figures create the image of the stability behaviour of examined composite plates.

  17. 两种不同强塑性薄钢板抗弹性能的试验和数值模拟%Experiment and Numerical Simulation on Ballistic Performance of Two Thin Steel Plates With Different Strength and Ductility

    Institute of Scientific and Technical Information of China (English)

    肖红亮; 时捷; 曹文全; 雍岐龙; 董瀚

    2012-01-01

    51B-type 7.62mm pistol bullets were fired at thin steel plates with different strength and ductility. And the numerical simulation for the experiments was carried on by ANSYS/LS-DYNA too. The macro-appearance in the process of testing and numerical simulation were compared, such as the impact craters, bulge height and residual projectile size. At last, combined with the energy absorption of the steel plate and the bullet, the influence of the strength and ductility on ballistic performance was analyzed. The results show that: two tested steel plates almost have the same ballistic performance against the 5113 type 7.62 mm pistol bullets, although the very different tensile strength and elongation they have. The numerical simulation result is consistent with the experiment, and it can re- flect the process of the bullets impact target rightly. To the higher strength steel plate, energy absorption by making the projectile deformation is greater than the lower strength one, and to the higher ductility steel plate, energy absorption though its own deformation is larger than the lower ductility one. Thus, the result of two tested steel plates almost have the same ballistic performance is explained.%利用51B式7.62mm手枪弹对不同强度和塑性的薄钢板进行枪击试验,采用ANSYS/LS-DYNA软件对试验过程进行数值模拟,对试验和数值模拟过程的钢板破坏形貌、背凸高度、残余弹丸长度等宏观形貌进行比较。结合抗弹过程中弹丸和钢板消耗的能量,分析了强度和塑性对钢板抗弹性能的影响。结果表明:尽管两种钢板的抗拉强度和断后伸长率差异较大,但其抗51B式7.62mm手枪弹性能相当。试验和数值模拟结果吻合较好,模拟方法能够正确地反映弹丸冲击靶板过程。因较高强度钢板使弹丸变形消耗的能量大于较低强度钢板,塑性较好钢板本身变形消耗的能量大于较低塑性钢板,从而解释了两种钢板抗弹性能相当的试验结果。

  18. Blue Willow Story Plates

    Science.gov (United States)

    Fontes, Kris

    2009-01-01

    In the December 1997 issue of "SchoolArts" is a lesson titled "Blue Willow Story Plates" by Susan Striker. In this article, the author shares how she used this lesson with her middle-school students many times over the years. Here, she describes a Blue Willow plate painting project that her students made.

  19. Create Your Plate

    Medline Plus

    Full Text Available ... In Memory In Honor Become a Member En Español Type 1 Type 2 About Us Online Community ... Page Text Size: A A A Listen En Español Create Your Plate Create Your Plate is a ...

  20. Create Your Plate

    Medline Plus

    Full Text Available ... Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal Planning ... Planning Meals Diabetes Meal Plans and a Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets ...

  1. Hybrid Q-switched laser with MoSsub>2sub> saturable absorber and AOM driven sub-nanosecond KTP-OPO.

    Science.gov (United States)

    Qiao, Junpeng; Zhao, Shengzhi; Yang, Kejian; Zhao, Jia; Li, Guiqiu; Li, Dechun; Li, Tao; Qiao, Wenchao

    2017-02-20

    Two-dimensional (2D) materials, especially transition-metal dichalcogenides, such as molybdenum disulfide (MoSsub>2sub>) and tungsten disulfide (WSsub>2sub>), have attracted great interests due to their exceptional optical properties as saturable absorbers in laser systems. In this work, at first, we presented a diode-pumped passively Q-switched laser with MoSsub>2sub> saturable absorber (MoSsub>2sub>-SA). At an incident pump power of 6.54 W, a maximum output power of 1.15 W with a minimum pulse duration of 70.6 ns was obtained, which is the shortest pulse duration of diode pumped passively Q-switched laser with MoSsub>2sub>-SA to the best of our knowledge. Then, by using a hybrid Q-switched laser with a MoSsub>2sub>-SA and an acousto-optic modulator (AOM) as pumping fundamental laser, a sub-nanosecond KTiOPOsub>4sub> (KTP) based intracavity optical parametric oscillation (IOPO) was realized. With an incident pump power of 10.2 W and AOM repetition rate of 10 kHz, the maximum output power of 183 mW with minimum pulse duration of 850 ps was obtained. The experimental results indicate that the IOPO pumped by the hybrid Q-switched laser with AOM and MoSsub>2sub>-SA can generate signal wave with shorter pulse duration than those IOPOs pumped by hybrid Q-switched laser with AOM and Cr4+:YAG or single-walled carbon nanotube saturable absober (SWCNT-SA) or monolayer graphene SA.

  2. Mechanical properties of Indonesian-made narrow dynamic compression plate.

    Science.gov (United States)

    Dewo, P; van der Houwen, E B; Sharma, P K; Magetsari, R; Bor, T C; Vargas-Llona, L D; van Horn, J R; Busscher, H J; Verkerke, G J

    2012-09-01

    Osteosynthesis plates are clinically used to fixate and position a fractured bone. They should have the ability to withstand cyclic loads produced by muscle contractions and total body weight. The very high demand for osteosynthesis plates in developing countries in general and in Indonesia in particular necessitates the utilisation of local products. In this paper, we investigated the mechanical properties, i.e. proportional limit and fatigue strength of Indonesian-made Narrow Dynamic Compression Plates (Narrow DCP) as one of the most frequently used osteosynthesis plates, in comparison to the European AO standard plate, and its relationship to geometry, micro structural features and surface defects of the plates. All Indonesian-made plates appeared to be weaker than the standard Narrow DCP because they consistently failed at lower stresses. Surface defects did not play a major role in this, although the polishing of the Indonesian Narrow DCP was found to be poor. The standard plate showed indications of cold deformation from the production process in contrast to the Indonesian plates, which might be the first reason for the differences in strength. This is confirmed by hardness measurements. A second reason could be the use of an inferior version of stainless steel. The Indonesian plates showed lower mechanical behaviour compared to the AO-plates. These findings could initiate the development of improved Indonesian manufactured DCP-plates with properties comparable to commonly used plates, such as the standard European AO-plates.

  3. Dynamic Response of Three-Layered Annular Plate with Imperfections

    Directory of Open Access Journals (Sweden)

    Pawlus Dorota

    2015-02-01

    Full Text Available This paper presents the imperfection sensitivity of annular plate with three-layered structure. The plate composed of thin elastic facings and a thicker elastic core is loaded in facing plane. The classical issue of a three-layered plate was solved for dynamic deflection problem using the approximation methods: orthogonalization and finite difference. The solution includes the axisymmetric and asymmetric plate modes of the dynamic stability loss. The evaluation of the rate of plate sensitivity to imperfection of plate preliminary geometry has been enriched by the analysis of plate models built of finite elements. The ABAQUS program has been used. The numerous calculation results in the form of deflection characteristics, buckling modes, values of critical parameters create the view of response of dynamic plate structure with different rate of imperfection and linear in time loading growth, too.

  4. Mechanism of High Pressure Difference of Plate Heat Exchanger in One Power Station%某电厂中板式换热器压差高的问题分析

    Institute of Scientific and Technical Information of China (English)

    曹新明; 饶宛; 肖雄; 高建强

    2015-01-01

    Plate heat exchanger is widely applied to many industries with its own advantages.Plate heat exchanger of the closed cooling water system in one power station went wrong with high pressure difference during the operation,which has affected the normal operation of the unit.This paper analyzes the problem from the aspects of equipment operation, operating,design,etc.It is concluded from the analysis that the main causes of high pressure drop are the installation of the measuring point and the margin is not enough at the design calculation.%板式换热器以其自身的优点被广泛应用到许多行业中,而某电厂的闭式冷却水系统中的板式换热器在运行中出现压差高报警问题,影响了机组的正常运行.从设备运行、制造、设计等方面对其进行分析,经过分析研究得到影响压差高的因素,其中主要因素是测点的安装问题和设计计算时裕度不够.

  5. Simulation of Armor-piercing Explosive Projectile on Penetration Target Plate with Different Material%穿甲爆破弹对不同材料靶板的侵彻仿真

    Institute of Scientific and Technical Information of China (English)

    肖振东

    2016-01-01

    In order to research the simulation of armor-piercing explosive projectile on penetration target plate with different material,based on ANSYS/ls-dyna finite element analysis software,to the thickness of the target board variable parameters for simulation,armor blasting and target plate model, numerical simulation, the penetration process. The target state stress nephogram, explosive projectile wearing by stress conditions and residual velocity of projectile wearing a target such as conclusion, provide the basis for armor-piercing explosive projectile design of the penetration.%为获得穿甲爆破弹对不同材料靶板的侵彻情况,基于ANSYS/LS-DYNA有限元分析软件,以靶板的厚度参数为仿真变量,建立穿甲爆破弹及靶板模型,进行数值模拟,再现了侵彻过程。得到了弹丸穿靶状态受力云图、炸药所受应力情况和弹丸穿靶的剩余速度等结论,为半穿甲弹结构的设计提供了依据。

  6. Optimization Design of Thermal Conduction Enhanced PCM Plates for Simulating the Infrared Signature of Steel Plate

    Institute of Scientific and Technical Information of China (English)

    YE Hong; JIANG Li-feng

    2008-01-01

    Phase change material (PCM) can be used to prepare the infrared false targets for realizing all-weather passive infrared decoy, but its low thermal conductivity is a great blockage to the simulation of the infrared signature of thick metal plates. For that reason, a method of simulating the infrared signature of thick steel plates by thermal conduction enhanced PCM, including the aluminum fins, is proposed. A physical and mathematic model is set up, and the infrared signature simulation of thick steel plate is investigated numerically. The effects of the distribution density and thickness of fins and the thickness of PCM plate on the simulation results are discussed, and the reasonable construction parameters of PCM plates used to simulate the steel plates of different thickness are obtained.

  7. A new refined theory of plates with transverse shear deformation for moderately thick and thick plates

    CERN Document Server

    Valle, Jose Miguel Martinez

    2015-01-01

    In this paper we propose a new refined shear deformation plate theory which possesses a series of desirable features, the most salient of which are as follows: (i) The loads, which are generally considered to be applied on the middle surface of the plate, act on the upper surface of the plate; (ii) The equations are applicable to the calculation of the stresses in isotropic plates and provide the same order of accuracy as several theories with second order shear deformation effects; (iii) It constitutes a theory, in the sense defined by Love, since it gives easy expressions for application to problems in different fields in architecture and civil engineering

  8. Pixelated neutron image plates

    Science.gov (United States)

    Schlapp, M.; Conrad, H.; von Seggern, H.

    2004-09-01

    Neutron image plates (NIPs) have found widespread application as neutron detectors for single-crystal and powder diffraction, small-angle scattering and tomography. After neutron exposure, the image plate can be read out by scanning with a laser. Commercially available NIPs consist of a powder mixture of BaFBr : Eu2+ and Gd2O3 dispersed in a polymer matrix and supported by a flexible polymer sheet. Since BaFBr : Eu2+ is an excellent x-ray storage phosphor, these NIPs are particularly sensitive to ggr-radiation, which is always present as a background radiation in neutron experiments. In this work we present results on NIPs consisting of KCl : Eu2+ and LiF that were fabricated into ceramic image plates in which the alkali halides act as a self-supporting matrix without the necessity for using a polymeric binder. An advantage of this type of NIP is the significantly reduced ggr-sensitivity. However, the much lower neutron absorption cross section of LiF compared with Gd2O3 demands a thicker image plate for obtaining comparable neutron absorption. The greater thickness of the NIP inevitably leads to a loss in spatial resolution of the image plate. However, this reduction in resolution can be restricted by a novel image plate concept in which a ceramic structure with square cells (referred to as a 'honeycomb') is embedded in the NIP, resulting in a pixelated image plate. In such a NIP the read-out light is confined to the particular illuminated pixel, decoupling the spatial resolution from the optical properties of the image plate material and morphology. In this work, a comparison of experimentally determined and simulated spatial resolutions of pixelated and unstructured image plates for a fixed read-out laser intensity is presented, as well as simulations of the properties of these NIPs at higher laser powers.

  9. Plate removal following orthognathic surgery.

    Science.gov (United States)

    Little, Mhairi; Langford, Richard Julian; Bhanji, Adam; Farr, David

    2015-11-01

    The objectives of this study are to determine the removal rates of orthognathic plates used during orthognathic surgery at James Cook University Hospital and describe the reasons for plate removal. 202 consecutive orthognathic cases were identified between July 2004 and July 2012. Demographics and procedure details were collected for these patients. Patients from this group who returned to theatre for plate removal between July 2004 and November 2012 were identified and their notes were analysed for data including reason for plate removal, age, smoking status, sex and time to plate removal. 3.2% of plates were removed with proportionally more plates removed from the mandible than the maxilla. 10.4% of patients required removal of one or more plate. Most plates were removed within the first post-operative year. The commonest reasons for plate removal were plate exposure and infection. The plate removal rates in our study are comparable to those seen in the literature.

  10. Anisotropic elastic plates

    CERN Document Server

    Hwu, Chyanbin

    2010-01-01

    As structural elements, anisotropic elastic plates find wide applications in modern technology. The plates here are considered to be subjected to not only in plane load but also transverse load. In other words, both plane and plate bending problems as well as the stretching-bending coupling problems are all explained in this book. In addition to the introduction of the theory of anisotropic elasticity, several important subjects have are discussed in this book such as interfaces, cracks, holes, inclusions, contact problems, piezoelectric materials, thermoelastic problems and boundary element a

  11. Plating in Top Agar

    OpenAIRE

    sprotocols

    2014-01-01

    1. Warm plates to room temperature before use. Cold plates causes the top agar to solidify irregularly. DO not warm plates to 37° as the top agar will take forever to solidify. - Prepare top agar as the appropriate liquid medium with 0.7% agar. Keeping 100 mL bottles is convenient. For phages, use λ top agar, which is less rich and yields bigger plaques. - Melt top agar in the microwave completely. Allow the agar to boil after liquification; incompletely melted agar looks liquid, but is...

  12. A Study of the Effect of Gold Thickness Distribution in the Jet Plating Process to Optimize Gold Usage and Plating Voltage Using Design of Experiments

    Directory of Open Access Journals (Sweden)

    Aramphongphun Chuckaphun

    2016-01-01

    Full Text Available A gold plating process in the electronics industry can be classified as (i all surface plating or (ii selective plating. Selective plating is more widely used than all surface plating because it can save more gold used in the plating process and takes less plating time. In this research, the selective plating process called jet plating was studied. Factors that possibly affected the gold usage and plating voltage were also studied to reduce the production cost. These factors included (a plating temperature, (b crystal (inhibitor amount, (c distance between workpiece and anode, (d plating current and (e plating speed. A two-level Full Factorial design with center points was first performed to screen the factors. A Central Composite Design (CCD was then employed to optimize the factors in jet plating. The amount of gold usage should be reduced to 0.366 g / 10,000 pieces, the plating speed should be increased to 4 m/min and the plating voltage should not exceed 8.0 V. According to the analysis, the optimal settings should be as follows: the plating temperature at 55.5 deg C, the crystal amount at 90%, the distance at 0.5 mm, the plating current at 2.8 A, and the plating speed at 4.5 m/min. This optimal setting led to gold usage of 0.350 g / 10,000 pieces and a plating voltage of 7.16 V. Confirmation runs of 30 experiments at the optimal conditions were then performed. It was found that the gold usage and the plating voltage of the confirmation runs were not different from the optimized gold usage and plating voltage. The optimal condition was then applied in production, which could reduce the gold usage by 4.5% and increase the plating speed by 12.5% while the plating voltage did not exceed the limit.

  13. Create Your Plate

    Medline Plus

    Full Text Available ... blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ... but changes the portion sizes so you are getting larger portions of non-starchy vegetables and a ...

  14. Create Your Plate

    Medline Plus

    Full Text Available ... blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ... 4/Box) Taking the guesswork out of portion control has never been easier. It can be a ...

  15. Tectonic Plate Movement.

    Science.gov (United States)

    Landalf, Helen

    1998-01-01

    Presents an activity that employs movement to enable students to understand concepts related to plate tectonics. Argues that movement brings topics to life in a concrete way and helps children retain knowledge. (DDR)

  16. MyPlate

    Science.gov (United States)

    ... our stage of life, situations, preferences, access to food, culture, traditions, and the personal decisions we make over time. All your food and beverage choices count. MyPlate offers ideas and ...

  17. Create Your Plate

    Medline Plus

    Full Text Available ... blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ... you have an easy portion control solution that works. Last Reviewed: October 8, 2015 Last Edited: September ...

  18. Designing Assemblies Of Plates

    Science.gov (United States)

    Williams, F. W.; Kennedy, D.; Butler, R.; Aston, G.; Anderson, M. S.

    1992-01-01

    VICONOPT calculates vibrations and instabilities of assemblies of prismatic plates. Designed for efficient, accurate analysis of buckling and vibration, and for optimum design of panels of composite materials. Written in FORTRAN 77.

  19. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal Planning What Can I Eat? Making Healthy Food Choices Diabetes Superfoods Non-starchy Vegetables Grains and Starchy Vegetables ...

  20. Create Your Plate

    Medline Plus

    Full Text Available ... Recipes Association Cookbook Recipes Planning Meals Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning ... serving of dairy or both as your meal plan allows. Choose healthy fats in small amounts. For ...

  1. Create Your Plate

    Medline Plus

    Full Text Available ... 1 Diabetes Get Started Safely Get And Stay Fit Types of Activity Weight Loss Assess Your Lifestyle ... manage portion control wherever you are. Now, our best-selling, sectioned to-go plate with easy-sealing ...

  2. Create Your Plate

    Medline Plus

    Full Text Available ... Plate is a simple and effective way to manage your blood glucose levels and lose weight. With ... been easier. It can be a challenge to manage portion control wherever you are. Now, our best- ...

  3. Tectonic Plate Movement.

    Science.gov (United States)

    Landalf, Helen

    1998-01-01

    Presents an activity that employs movement to enable students to understand concepts related to plate tectonics. Argues that movement brings topics to life in a concrete way and helps children retain knowledge. (DDR)

  4. Create Your Plate

    Medline Plus

    Full Text Available ... Carbohydrates Carbohydrate Counting Make Your Carbs Count Glycemic ... to manage portion control wherever you are. Now, our best-selling, sectioned to-go plate with easy-sealing ...

  5. Effect of different surface treatments on the stability of stainless steels for use as bipolar plates in low and high temperature proton exchange membrane fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Richards, J.; Schmidt, K. [Fraunhofer-Institut fuer Chemische Technologie (ICT), Wolfsburg (Germany); Tuebke, J.; Cremers, C. [Fraunhofer-Institut fuer Chemische Technologie (ICT), Pfinztal (Germany)

    2010-07-01

    The stability of different stainless steels against corrosion under simulated low and high temperature proton exchange membrane fuel cell (PEMFC) operating conditions was studied. These investigations showed a moderate corrosion resistance for a couple of steels under LT-PEMFC conditions. However, for the HT-PEMFC conditions all specimens except one exhibit visible corrosion traces. With regards to their corrosion resistance after different surface treatments results show a minor improvement in corrosion resistance after the electro polishing process for most of the tested stainless steel samples. (orig.)

  6. Origami - Folded Plate Structures

    OpenAIRE

    Buri, Hans Ulrich

    2010-01-01

    This research investigates new methods of designing folded plate structures that can be built with cross-laminated timber panels. Folded plate structures are attractive to both architects and engineers for their structural, spatial, and plastic qualities. Thin surfaces can be stiffened by a series of folds, and thus not only cover space, but also act as load bearing elements. The variation of light and shadow along the folded faces emphasizes the plas...

  7. Fractal multifiber microchannel plates

    Science.gov (United States)

    Cook, Lee M.; Feller, W. B.; Kenter, Almus T.; Chappell, Jon H.

    1992-01-01

    The construction and performance of microchannel plates (MCPs) made using fractal tiling mehtods are reviewed. MCPs with 40 mm active areas having near-perfect channel ordering were produced. These plates demonstrated electrical performance characteristics equivalent to conventionally constructed MCPs. These apparently are the first MCPs which have a sufficiently high degree of order to permit single channel addressability. Potential applications for these devices and the prospects for further development are discussed.

  8. Numerical analysis of cross shear plate rolling

    DEFF Research Database (Denmark)

    Zhang, Wenqi; Bay, Niels

    1997-01-01

    The rolling process is widely applied for industrial production of metal plates. In conventional plate rolling the two work rolls are rotating at the same peripheral speed. By introducing a specific difference in the speed of the two work rolls, cross shear rolling is introduced forming a central...... are in the roll gap, the position and the size of the shear zone and the rolling load are calculated. Experimental results are presented verifying the calculations. The numerical analysis facilitates a better understanding of the mechanics in cross shear plate rolling....

  9. Enhanced-transmission metamaterials as anisotropic plates

    Science.gov (United States)

    Baida, F. I.; Boutria, M.; Oussaid, R.; van Labeke, D.

    2011-07-01

    We present an original design of anisotropic metamaterial plates exhibiting extraordinary transmission through perfectly conductor metallic screens perforated by a subwavelength double-pattern rectangular aperture array. The polarization properties of the fundamental guided mode inside the apertures are at the origin of the anisotropy. The metal thickness is a key parameter that is adjusted in order to get the desired value of the phase difference between the two transversal electromagnetic field components. As an example, we treat the case of a half-wave plate having 92% transmission coefficient. Such a study can be easily extended to design anisotropic plates operating in terahertz or microwave domains.

  10. FLEXURAL WAVE PROPAGATION IN NARROW MINDLIN'S PLATE

    Institute of Scientific and Technical Information of China (English)

    HU Chao; HAN Gang; FANG Xue-qian; HUANG Wen-hu

    2006-01-01

    Appling Mindlin's theory of thick plates and Hamilton system to propagation of elastic waves under free boundary condition, a solution of the problem was given.Dispersion equations of propagation mode of strip plates were deduced from eigenfunction expansion method. It was compared with the dispersion relation that was gained through solution of thick plate theory proposed by Mindlin. Based on the two kinds of theories,the dispersion curves show great difference in the region of short waves, and the cutoff frequencies are higher in Hamiltonian systems. However, the dispersion curves are almost the same in the region of long waves.

  11. Vibration and Buckling of Web Plate of the Plate Girder

    OpenAIRE

    高橋, 和雄; 呉, 明強; 中澤, 聡志; 筑紫, 宏之

    1998-01-01

    The vibration and buckling of the web of the plate girder are studied in this paper. The small deflection theory of the thin plate is used. The finite strip method is employed to solve vibration and buckling of the plate girder. Natural frequenies of buckling properties are shown for various plate girder bridges.

  12. Effect of different thisamine receptor agonists and antagonists on the pain threshold caused by hot plate and abdominal writhing in mice

    OpenAIRE

    D. Farzin; L.Asghari; M.Norousi

    2000-01-01

    SummaryBackground and purpose: Histamine is a neurotransmitter present in the brain of mammals which produces its physiological effects on target cells by stimulation of three types of receptors H1, H2 and H3.Various reports nowadays indicate the role of histamine in reduction of pain transmission. This study was designed to determine the role of histamine receptors in reduction of pain.Materials and Methods: In this study, effects of different histamine receptor agonists and antagonists on t...

  13. Sub-nanosecond time-resolved ambient-pressure X-ray photoelectron spectroscopy setup for pulsed and constant wave X-ray light sources.

    Science.gov (United States)

    Shavorskiy, Andrey; Neppl, Stefan; Slaughter, Daniel S; Cryan, James P; Siefermann, Katrin R; Weise, Fabian; Lin, Ming-Fu; Bacellar, Camila; Ziemkiewicz, Michael P; Zegkinoglou, Ioannis; Fraund, Matthew W; Khurmi, Champak; Hertlein, Marcus P; Wright, Travis W; Huse, Nils; Schoenlein, Robert W; Tyliszczak, Tolek; Coslovich, Giacomo; Robinson, Joseph; Kaindl, Robert A; Rude, Bruce S; Ölsner, Andreas; Mähl, Sven; Bluhm, Hendrik; Gessner, Oliver

    2014-09-01

    An apparatus for sub-nanosecond time-resolved ambient-pressure X-ray photoelectron spectroscopy studies with pulsed and constant wave X-ray light sources is presented. A differentially pumped hemispherical electron analyzer is equipped with a delay-line detector that simultaneously records the position and arrival time of every single electron at the exit aperture of the hemisphere with ~0.1 mm spatial resolution and ~150 ps temporal accuracy. The kinetic energies of the photoelectrons are encoded in the hit positions along the dispersive axis of the two-dimensional detector. Pump-probe time-delays are provided by the electron arrival times relative to the pump pulse timing. An average time-resolution of (780 ± 20) ps (FWHM) is demonstrated for a hemisphere pass energy E(p) = 150 eV and an electron kinetic energy range KE = 503-508 eV. The time-resolution of the setup is limited by the electron time-of-flight (TOF) spread related to the electron trajectory distribution within the analyzer hemisphere and within the electrostatic lens system that images the interaction volume onto the hemisphere entrance slit. The TOF spread for electrons with KE = 430 eV varies between ~9 ns at a pass energy of 50 eV and ~1 ns at pass energies between 200 eV and 400 eV. The correlation between the retarding ratio and the TOF spread is evaluated by means of both analytical descriptions of the electron trajectories within the analyzer hemisphere and computer simulations of the entire trajectories including the electrostatic lens system. In agreement with previous studies, we find that the by far dominant contribution to the TOF spread is acquired within the hemisphere. However, both experiment and computer simulations show that the lens system indirectly affects the time resolution of the setup to a significant extent by inducing a strong dependence of the angular spread of electron trajectories entering the hemisphere on the retarding ratio. The scaling of the angular spread with

  14. Bending and stretching of plates

    CERN Document Server

    Mansfield, E H; Hemp, W S

    1964-01-01

    The Bending and Stretching of Plates deals with elastic plate theory, particularly on small- and large-deflexion theory. Small-deflexion theory concerns derivation of basic equations, rectangular plates, plates of various shapes, plates whose boundaries are amenable to conformal transformation, plates with variable rigidity, and approximate methods. Large-deflexion theory includes general equations and some exact solutions, approximate methods in large-deflexion theory, asymptotic large-deflexion theories for very thin plates. Asymptotic theories covers membrane theory, tension field theory, a

  15. Performance of four different agar plate methods for rectal swabs, synergy disk tests and metallo-β-lactamase Etest for clinical isolates in detecting carbapenemase-producing Klebsiella pneumoniae.

    Science.gov (United States)

    Papadimitriou-Olivgeris, Matthaios; Vamvakopoulou, Sophia; Spyropoulou, Αikaterini; Bartzavali, Christina; Marangos, Markos; Anastassiou, Evangelos D; Spiliopoulou, Iris; Christofidou, Myrto

    2016-09-01

    The aims of the study were to compare four different agar plate methods in the identification of carbapenemase-producing Klebsiella pneumoniae (CP-Kp) from rectal samples and to assess the role of phenotypic methodologies in the identification of carbapenemase type from clinical K. pneumoniae isolates. Two chromogenic agars (Brilliance CRE and CHROMagar KPC) were compared to MacConkey agar plates with ertapenem (ERT) or imipenem (IMP) disks for the identification of CP-Kp from 912 rectal swabs. CP-Kp was detected in 329 samples by either agar methodology (299 K. pneumoniae carbapenemase positive, 27 Verona integron-encoded metallo-β-lactamase positive and 3 K. pneumoniae carbapenemase and Verona integron-encodedmetallo-β-lactamase positive). Sensitivity of Brilliance CRE, CHROMagar KPC and MacConkey agar plus IMP or ERT disk (inhibition zone carbapenemase type as compared to PCR results (blaVIM, blaKPC and blaNDM) from 2515 isolates with reduced susceptibility to any of the Etest-examined carbapenems (ERT, IMP or meropenem). Metallo-β-lactamase MP/MPI Etest was applied in 616 isolates. Sensitivity was 98.4, 90.9 and 82.2 % for phenylboronic acid synergy test, EDTA synergy test and metallo-β-lactamase Etest, respectively, while their specificity was high (>97.5 %). Phenotypic methodologies can provide reliable results for the identification of carbapenemase production among K. pneumoniae isolates. Chromogenic agars can be applied in high-risk patients as part of surveillance and infection control programs.

  16. Electrical conductivity of old oceanic mantle in the northwestern Pacific I: 1-D profiles suggesting differences in thermal structure not predictable from a plate cooling model

    Science.gov (United States)

    Baba, Kiyoshi; Tada, Noriko; Matsuno, Tetsuo; Liang, Pengfei; Li, Ruibai; Zhang, Luolei; Shimizu, Hisayoshi; Abe, Natsue; Hirano, Naoto; Ichiki, Masahiro; Utada, Hisashi

    2017-08-01

    Seafloor magnetotelluric (MT) experiments were recently conducted in two areas of the northwestern Pacific to investigate the nature of the old oceanic upper mantle. The areas are far from any tectonic activity, and "normal" mantle structure is therefore expected. The data were carefully analyzed to reduce the effects of coastlines and seafloor topographic changes, which are significant boundaries in electrical conductivity and thus distort seafloor MT data. An isotropic, one-dimensional electrical conductivity profile was estimated for each area. The profiles were compared with those obtained from two previous study areas in the northwestern Pacific. Between the four profiles, significant differences were observed in the thickness of the resistive layer beyond expectations based on cooling of homogeneous oceanic lithosphere over time. This surprising feature is now further clarified from what was suggested in a previous study. To explain the observed spatial variation, dynamic processes must be introduced, such as influence of the plume associated with the formation of the Shatsky Rise, or spatially non-uniform, small-scale convection in the asthenosphere. There is significant room of further investigation to determine a reasonable and comprehensive interpretation of the lithosphere-asthenosphere system beneath the northwestern Pacific. The present results demonstrate that electrical conductivity provides key information for such investigation.[Figure not available: see fulltext.

  17. License Plate Recognition for Parking Control System by Mathematical Morphology

    Institute of Scientific and Technical Information of China (English)

    Javier Ortiz; Alberto Gómez

    2014-01-01

    Nowadays, license plate recognition for parking systems is a critical task to provide automatic control of customers and payment. This paper introduces a new method for automatic recognition of license plates of vehicles by mathematical morphology. The proposed method can provide the license plate number of the plates in different light conditions, colors, sizes, and inclination (angles). The algorithm can recognize the license plates of European Union vehicles quickly and correctly. The pattern learning of mathematical skeletons has high efficiency in the process. The performance of the algorithm is demonstrated well by the test in a parking control system.

  18. Plating of proximal humeral fractures.

    Science.gov (United States)

    Martetschläger, Frank; Siebenlist, Sebastian; Weier, Michael; Sandmann, Gunther; Ahrens, Philipp; Braun, Karl; Elser, Florian; Stöckle, Ulrich; Freude, Thomas

    2012-11-01

    The optimal treatment for proximal humeral fractures is controversial. Few data exist concerning the influence of the surgical approach on the outcome. The purpose of this study was to evaluate the clinical and radiological outcomes of proximal humeral fractures treated with locking plate fixation through a deltopectoral vs an anterolateral deltoid-splitting approach. Of 86 patients who met the inclusion criteria, 70 were available for follow-up examination. Thirty-three patients were treated through a deltopectoral approach and 37 through an anterolateral deltoid-splitting approach. In all cases, open reduction and internal fixation with a PHILOS locking plate (Synthes, Umkirch, Germany) was performed. Clinical follow-up included evaluation of pain, shoulder mobility, and strength. Constant score and Disabilities of the Arm, Shoulder and Hand (DASH) score were assessed. A clinical neurological examination of the axillary nerve was also performed. Consolidation, reduction, and appearance of head necrosis were evaluated radiographically. After a mean follow-up of 33 months, Constant scores, DASH scores, and American Shoulder and Elbow Surgeons scores showed no significant differences between the groups. Clinical neurologic examination of the axillary nerve revealed no obvious damage to the nerve in either group. Deltopectoral and anterolateral detoid-splitting approaches for plate fixation of proximal humeral fractures are safe and provide similar clinical outcomes. The results of this study suggest that the approach can be chosen according to surgeon preference.

  19. Anterior cervical plating

    Directory of Open Access Journals (Sweden)

    Gonugunta V

    2005-01-01

    Full Text Available Although anterior cervical instrumentation was initially used in cervical trauma, because of obvious benefits, indications for its use have been expanded over time to degenerative cases as well as tumor and infection of the cervical spine. Along with a threefold increase in incidence of cervical fusion surgery, implant designs have evolved over the last three decades. Observation of graft subsidence and phenomenon of stress shielding led to the development of the new generation dynamic anterior cervical plating systems. Anterior cervical plating does not conclusively improve clinical outcome of the patients, but certainly enhances the efficacy of autograft and allograft fusion and lessens the rate of pseudoarthrosis and kyphosis after multilevel discectomy and fusions. A review of biomechanics, surgical technique, indications, complications and results of various anterior cervical plating systems is presented here to enable clinicians to select the appropriate construct design.

  20. High-voltage isolation transformer for sub-nanosecond rise time pulses constructed with annular parallel-strip transmission lines.

    Science.gov (United States)

    Homma, Akira

    2011-07-01

    A novel annular parallel-strip transmission line was devised to construct high-voltage high-speed pulse isolation transformers. The transmission lines can easily realize stable high-voltage operation and good impedance matching between primary and secondary circuits. The time constant for the step response of the transformer was calculated by introducing a simple low-frequency equivalent circuit model. Results show that the relation between the time constant and low-cut-off frequency of the transformer conforms to the theory of the general first-order linear time-invariant system. Results also show that the test transformer composed of the new transmission lines can transmit about 600 ps rise time pulses across the dc potential difference of more than 150 kV with insertion loss of -2.5 dB. The measured effective time constant of 12 ns agreed exactly with the theoretically predicted value. For practical applications involving the delivery of synchronized trigger signals to a dc high-voltage electron gun station, the transformer described in this paper exhibited advantages over methods using fiber optic cables for the signal transfer system. This transformer has no jitter or breakdown problems that invariably occur in active circuit components.

  1. Energy transfer in double plate system dynamics

    Institute of Scientific and Technical Information of China (English)

    Katica (Stevanovic) Hedrih

    2008-01-01

    The study of energy transfer between coupled subsystems in a hybrid system is very important for applications. This paper presents an analytical analysis of energy transfer between plates of a visco-elastically connected double-plate system in free transversal vibrations. The analytical analysis shows that the visco-elastic connection between plates is responsible for the appearance of two-frequency regime in the time function, which corresponds to one eigen amplitude function of one mode, and also that time functions of different vibration modes are uncoupled, but energy transfer between plates in one eigen mode appears. It was shown for each shape of vibrations. Series of the two Lyapunov exponents corresponding to the one eigen amplitude mode are expressed by using the energy of the corresponding eigen amplitude time component.

  2. Casimir force between metal plate and dielectric plate

    Institute of Scientific and Technical Information of China (English)

    刘中柱; 邵成刚; 罗俊

    1999-01-01

    The Casimir effect between metal plate and dielectric plate is discussed with 1+1-dimensional potential model without using cut-off method. Calculation shows that the Casimir force between metal plate and dielectric plate is determined not only by the potential V0, the dielectric thickness and the distance α between the metal plate and dielectric plate, but also by the dimension of the vessel. When α is far less than the dimension of the vessel, the Casimir force Fc∝α(-1); conversely Fc∝α-2. This result is significant for Casimir force experiment.

  3. Nuclear reactor alignment plate configuration

    Energy Technology Data Exchange (ETDEWEB)

    Altman, David A; Forsyth, David R; Smith, Richard E; Singleton, Norman R

    2014-01-28

    An alignment plate that is attached to a core barrel of a pressurized water reactor and fits within slots within a top plate of a lower core shroud and upper core plate to maintain lateral alignment of the reactor internals. The alignment plate is connected to the core barrel through two vertically-spaced dowel pins that extend from the outside surface of the core barrel through a reinforcement pad and into corresponding holes in the alignment plate. Additionally, threaded fasteners are inserted around the perimeter of the reinforcement pad and into the alignment plate to further secure the alignment plate to the core barrel. A fillet weld also is deposited around the perimeter of the reinforcement pad. To accomodate thermal growth between the alignment plate and the core barrel, a gap is left above, below and at both sides of one of the dowel pins in the alignment plate holes through with the dowel pins pass.

  4. Linear and nonlinear buckling analysis of a locally stretched plate

    Energy Technology Data Exchange (ETDEWEB)

    Kilardj, Madina; Ikhenzzen, Ghania [University of Sciences and Technology Houari Boumediene (U.S.T.H.B), Bab Ezzouar, Algiers (Algeria); Merssager, Tanguy; Kanit, Toufik [Laboratoire de Mecanique de Lille Universite Lille 1, Cite ScientifiqueVilleneuve d' Ascq cedex (France)

    2016-08-15

    Uniformly stretched thin plates do not buckle unless they are in special boundary conditions. However, buckling commonly occurs around discontinuities, such as cracks, cuts, narrow slits, holes, and different openings, of such plates. This study aims to show that buckling can also occur in thin plates that contain no defect or singularity when the stretching is local. This specific stability problem is analyzed with the finite element method. A brief literature review on stretched plates is presented. Linear and nonlinear buckling stress analyses are conducted for a partially stretched rectangular plate, and various load cases are considered to investigate the influence of the partial loading expanse on the critical tensile buckling load. Results are summarized in iso-stress areas, tables and graphs. Local stretching on one end of the plate induces buckling in the thin plate even without geometrical imperfection.

  5. Create Your Plate

    Medline Plus

    Full Text Available ... 1 Type 2 About Us Online Community Meal Planning Sign In Search: Search More Sites Search ≡ Are ... Fitness Home Food MyFoodAdvisor Recipes Association Cookbook Recipes Planning Meals Diabetes Meal Plans Create Your Plate Gluten ...

  6. Create Your Plate

    Medline Plus

    Full Text Available ... Create Your Plate is a simple and effective way to manage your blood glucose levels and lose weight. With ... year of delicious meals to help prevent and manage diabetes. Healthy Recipes: ... to your day with this guide. Ways to Give: Wear Your Cause on Your Sleeve - ...

  7. The Plate Tectonics Project

    Science.gov (United States)

    Hein, Annamae J.

    2011-01-01

    The Plate Tectonics Project is a multiday, inquiry-based unit that facilitates students as self-motivated learners. Reliable Web sites are offered to assist with lessons, and a summative rubric is used to facilitate the holistic nature of the project. After each topic (parts of the Earth, continental drift, etc.) is covered, the students will…

  8. Create Your Plate

    Medline Plus

    Full Text Available ... tax-deductible gift today can fund critical diabetes research and support vital diabetes education services that improve the ... way to manage your blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ...

  9. Create Your Plate

    Medline Plus

    Full Text Available ... 1 Type 2 About Us Online Community Meal Planning Sign In Search: Search More Sites Search ≡ Are ... Fitness Home Food MyFoodAdvisor Recipes Association Cookbook Recipes Planning Meals Diabetes Meal Plans Create Your Plate Gluten ...

  10. Create Your Plate

    Medline Plus

    Full Text Available ... tax-deductible gift today can fund critical diabetes research and support vital diabetes education services that improve the ... way to manage your blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ...

  11. Create Your Plate

    Medline Plus

    Full Text Available ... unsweetened tea or coffee. Featured Product Precise Portions® Go Healthy Travel Pack (4/Box) Taking the guesswork ... you are. Now, our best-selling, sectioned to-go plate with easy-sealing lid is offered in ...

  12. Create Your Plate

    Medline Plus

    Full Text Available ... manage portion control wherever you are. Now, our best-selling, sectioned to-go plate with easy-sealing lid is offered in a 4-pack. Whether ... Research & Practice We Are Research Leaders We Support Your Doctor ...

  13. INL HIP Plate Fabrication

    Energy Technology Data Exchange (ETDEWEB)

    B. H. Park; C. R. Clark; J. F. Jue

    2010-02-01

    This document outlines the process used to bond monolithic fuel plates by Hot Isostatic Pressing (HIP). This method was developed at Idaho National Laboratory (INL) for the Reduced Enrichment for Research and Test Reactors (RERTR) program. These foils have been used in a number of irradiation experiments in support of the United States Global Threat Reduction Initiative (GTRI) program.

  14. The Plate Tectonics Project

    Science.gov (United States)

    Hein, Annamae J.

    2011-01-01

    The Plate Tectonics Project is a multiday, inquiry-based unit that facilitates students as self-motivated learners. Reliable Web sites are offered to assist with lessons, and a summative rubric is used to facilitate the holistic nature of the project. After each topic (parts of the Earth, continental drift, etc.) is covered, the students will…

  15. Create Your Plate

    Medline Plus

    Full Text Available ... Planning Meals > Create Your Plate Share: Print Page Text Size: A A A Listen En Español Create ... somewhere in between, you have an easy portion control solution that works. Last Reviewed: October 8, 2015 Last Edited: ... Cost of Diabetes Advocate Toolkit Call to Congress Research & ...

  16. Measurements of the Rate Capability of Various Resistive Plate Chambers

    CERN Document Server

    Affatigato, M; Bilki, B; Corriveau, F; Freund, B; Johnson, N; Neubueser, C; Onel, Y; Repond, J; Xia, L

    2015-01-01

    Resistive Plate Chambers (RPCs) exhibit a significant loss of efficiency for the detection of particles, when subjected to high particle fluxes. This rate limitation is related to the usually high resistivity of the resistive plates used in their construction. This paper reports on measurements of the performance of three different glass RPC designs featuring a different total resistance of the resistive plates. The measurements were performed with 120 GeV protons at varying beam intensities

  17. Plates made with solid waste from the recycled paper industry.

    Science.gov (United States)

    Pelegrini, M; Gohr Pinheiro, I; Valle, J A B

    2010-02-01

    The results of assays carried out on plates used in the construction industry, manufactured entirely with solid wastes of a recycled paper plant, are presented and compared with the results obtained using agglomerated wood and plywood plates. Previous results had shown that wastes are composed essentially of polymers when these wastes are generated by recycled paper produced with the "waved type II" shavings. These solid wastes were placed in a mold that was heated and pressed with a hydraulic press in order to obtain the plates. The waste-produced plates were submitted to tests for humidity, swelling, water absorption, density, modulus of rupture-static bending, modulus of elasticity and direct screw withdrawal. These same assays had been carried out on two types of commercial wood plates, agglomerated wood and plywood, in order to compare the results with those obtained with the waste plate. Waste plates had similar behavior to the agglomerated wood plate, but it was possible to distinguish greater flexibility in the waste-produced plate and a significant difference in the tests for swelling and water absorption which showed the waste plate had a better performance than the agglomerated wood and plywood plates.

  18. Abrupt plate accelerations shape rifted continental margins

    Science.gov (United States)

    Brune, Sascha; Williams, Simon E.; Butterworth, Nathaniel P.; Müller, R. Dietmar

    2016-08-01

    Rifted margins are formed by persistent stretching of continental lithosphere until breakup is achieved. It is well known that strain-rate-dependent processes control rift evolution, yet quantified extension histories of Earth’s major passive margins have become available only recently. Here we investigate rift kinematics globally by applying a new geotectonic analysis technique to revised global plate reconstructions. We find that rifted margins feature an initial, slow rift phase (less than ten millimetres per year, full rate) and that an abrupt increase of plate divergence introduces a fast rift phase. Plate acceleration takes place before continental rupture and considerable margin area is created during each phase. We reproduce the rapid transition from slow to fast extension using analytical and numerical modelling with constant force boundary conditions. The extension models suggest that the two-phase velocity behaviour is caused by a rift-intrinsic strength-velocity feedback, which can be robustly inferred for diverse lithosphere configurations and rheologies. Our results explain differences between proximal and distal margin areas and demonstrate that abrupt plate acceleration during continental rifting is controlled by the nonlinear decay of the resistive rift strength force. This mechanism provides an explanation for several previously unexplained rapid absolute plate motion changes, offering new insights into the balance of plate driving forces through time.

  19. Image simulation for automatic license plate recognition

    Science.gov (United States)

    Bala, Raja; Zhao, Yonghui; Burry, Aaron; Kozitsky, Vladimir; Fillion, Claude; Saunders, Craig; Rodríguez-Serrano, José

    2012-01-01

    Automatic license plate recognition (ALPR) is an important capability for traffic surveillance applications, including toll monitoring and detection of different types of traffic violations. ALPR is a multi-stage process comprising plate localization, character segmentation, optical character recognition (OCR), and identification of originating jurisdiction (i.e. state or province). Training of an ALPR system for a new jurisdiction typically involves gathering vast amounts of license plate images and associated ground truth data, followed by iterative tuning and optimization of the ALPR algorithms. The substantial time and effort required to train and optimize the ALPR system can result in excessive operational cost and overhead. In this paper we propose a framework to create an artificial set of license plate images for accelerated training and optimization of ALPR algorithms. The framework comprises two steps: the synthesis of license plate images according to the design and layout for a jurisdiction of interest; and the modeling of imaging transformations and distortions typically encountered in the image capture process. Distortion parameters are estimated by measurements of real plate images. The simulation methodology is successfully demonstrated for training of OCR.

  20. Injection molding of micro patterned PMMA plate

    Institute of Scientific and Technical Information of China (English)

    Yeong-Eun YOO; Tae-Hoon KIM; Tae-Jin JE; Doo-Sun CHOI; Chang-Wan KIM; Sun-Kyung KIM

    2011-01-01

    A plastic plate with surface micro features was injection molded to investigate the effect of pressure rise of melt on the replication of the micro structures. Prism pattern, which is used in many optical applications, was selected as a model pattern. The prism pattern is 50 μm in pitch and 108° in the vertical angle. The overall size of the plate was 335 mm×213 mm and the thickness of the plate varied linearly from 2.6 mm to 0.7 mm. The prism pattern was firstly machined on the nickel plated core block using micro diamond tool and this machined pattern core was installed in a mold for injection molding of prism patterned plate. Polymethyl methacrylate (PMMA) was used as a molding material. The pressure and temperature of the melt in the cavity were measured at different positions in the cavity and the replication of the pattern was also measured at the same positions. The results show that the pressure or temperature profile through the process depends on the shape and the size of the plate. The replication is affected by the temperature and pressure profiles at the early stage of filling, which is right after the melt reaches the position to be measured.

  1. Abrupt plate accelerations shape rifted continental margins.

    Science.gov (United States)

    Brune, Sascha; Williams, Simon E; Butterworth, Nathaniel P; Müller, R Dietmar

    2016-08-11

    Rifted margins are formed by persistent stretching of continental lithosphere until breakup is achieved. It is well known that strain-rate-dependent processes control rift evolution, yet quantified extension histories of Earth's major passive margins have become available only recently. Here we investigate rift kinematics globally by applying a new geotectonic analysis technique to revised global plate reconstructions. We find that rifted margins feature an initial, slow rift phase (less than ten millimetres per year, full rate) and that an abrupt increase of plate divergence introduces a fast rift phase. Plate acceleration takes place before continental rupture and considerable margin area is created during each phase. We reproduce the rapid transition from slow to fast extension using analytical and numerical modelling with constant force boundary conditions. The extension models suggest that the two-phase velocity behaviour is caused by a rift-intrinsic strength--velocity feedback, which can be robustly inferred for diverse lithosphere configurations and rheologies. Our results explain differences between proximal and distal margin areas and demonstrate that abrupt plate acceleration during continental rifting is controlled by the nonlinear decay of the resistive rift strength force. This mechanism provides an explanation for several previously unexplained rapid absolute plate motion changes, offering new insights into the balance of plate driving forces through time.

  2. The Okhotsk Plate and the Eurasia-North America plate boundary zone.

    Science.gov (United States)

    Hindle, David; Mackey, Kevin

    2014-05-01

    The Eurasia-North America plate boundary zone transitions from spreading at rates of ~ 25mm/yr in the North Atlantic, to compression at rates of ~ 5mm/yr in the region of the Okhotsk plate. Because the pole of rotation between Eurasia and North America lies more or less on their mutual boundary, there is a linear change in rate along the boundary, and regions near the euler pole are subject to extremely low deformation rates. The Okhotsk - Eurasia - North America triple junction lies slightly south of the rotation pole, placing the Okhotsk plate entirely in a weakly contractional setting. Regions near the triple junction absorb 1mm/yr contraction. Further south, towards the shoreline of the Okhotsk sea, up to 5 mm/yr contraction may be absorbed within the plate. How shortening is accommodated across the boundary remains an open question. One possibility is wholesale extrusion of the entire Okhotsk plate (or possibly its northwestern corner) along two plate boundary strike slip faults (Eurasia-Okhostk and North America Okhotsk). The problem with this model is that the seismic record does not presently clearly support it, with the largest events distributed both within the plate interior and on its boundaries. This may suggest that instead, the Okhotsk plate, and particularly its north-western end, consists of a series of smaller blocks which shuffle against each other, partially accommodating extrusion, but also permitting some internal deformation and change of shape of the Okhotsk plate itself. We present analyses of the very sparse seismic record from the region, as well as geometric-kinematic, tectonic models of the possible deformation of northwest Okhotsk to try to better understand the different probabilities of how this slowly deforming plate boundary zone is behaving.

  3. Improved Zone Plate Coded Imaging Technique by Using Four Special Designed Gabor Zone Plates

    Institute of Scientific and Technical Information of China (English)

    CAO Lei-Feng; SHEN Yu-Ji; ZHENG Zhi-Jian; DING Yong-Kun

    2005-01-01

    @@ Direct-current component, high-order artifacts, and side lobe distortion provide serious drawbacks in the application of Fresnel zone plate coded imaging (ZPCI).The presentation provided here proposes a novel way to resolve all the above-mentioned problems.Four different Gabor zone plates are suggested to substitute the one Fresnel zone plate used in the conventional ZPCI.Perfect reconstruction will be obtained when integrally analysing the four coded images.Primary numerical simulation provided here shows good result.

  4. What Are Growth Plate Injuries?

    Science.gov (United States)

    ... plate injuries are:  Falling down  Competitive sports (like football)  Recreational activities. Other reasons for growth plate injuries are:  Child abuse  Injury from extreme cold (for ...

  5. Global crustal movement and tectonic plate boundary deformation constrained by the ITRF2008

    Directory of Open Access Journals (Sweden)

    Zhu Ze

    2012-08-01

    Full Text Available On the basis of the newly released International Terrestrial Reference Frame(ITRF2008 by the International Earth Rotation Service (IERS, a new global plate model ITRF2008 plate for the major plates is established. This ITRF2008-derived model is analyzed in comparison with NNR-NUVEL1A model, which is mainly based on geological and geophysical data. The Eurasia and Pacific plates display obvious differences in terms of the velocity fields derived from the two plate motion models. Plate acceleration is also introduced to characterize the differences of the two velocity fields which obtained from ITRF2008 -plate and NNR-NUVEL1A models for major individual plates. The results show that the Africa, South America and Eurasia plates are undergoing acceleration, while the North America and Australia plates are in the state of deceleration motion.

  6. Controlling Laminate Plate Elastic Behavior

    OpenAIRE

    Mareš, T.

    2004-01-01

    This paper aims to express the relation of a measure of laminate plate stiffness with respect to the fiber orientation of its plies. The inverse of the scalar product of the lateral displacement of the central plane and lateral loading of the plate is the measure of laminate plate stiffness. In the case of a simply supported rectangular laminate plate this measure of stiffness is maximized, and the optimum orientation of its plies is searched.

  7. Nonlinear analysis of flexible plates lying on elastic foundation

    Directory of Open Access Journals (Sweden)

    Trushin Sergey

    2017-01-01

    Full Text Available This article describes numerical procedures for analysis of flexible rectangular plates lying on elastic foundation. Computing models are based on the theory of plates with account of transverse shear deformations. The finite difference energy method of discretization is used for reducing the initial continuum problem to finite dimensional problem. Solution procedures for nonlinear problem are based on Newton-Raphson method. This theory of plates and numerical methods have been used for investigation of nonlinear behavior of flexible plates on elastic foundation with different properties.

  8. Notch sensitivity jeopardizes titanium locking plate fatigue strength.

    Science.gov (United States)

    Tseng, Wo-Jan; Chao, Ching-Kong; Wang, Chun-Chin; Lin, Jinn

    2016-12-01

    Notch sensitivity may compromise titanium-alloy plate fatigue strength. However, no studies providing head-to-head comparisons of stainless-steel or titanium-alloy locking plates exist. Custom-designed identically structured locking plates were made from stainless steel (F138 and F1314) or titanium alloy. Three screw-hole designs were compared: threaded screw-holes with angle edges (type I); threaded screw-holes with chamfered edges (type II); and non-threaded screw-holes with chamfered edges (type III). The plates' bending stiffness, bending strength, and fatigue life, were investigated. The stress concentration at the screw threads was assessed using finite element analyses (FEA). The titanium plates had higher bending strength than the F1314 and F138 plates (2.95:1.56:1) in static loading tests. For all metals, the type-III plate fatigue life was highest, followed by type-II and type-I. The type-III titanium plates had longer fatigue lives than their F138 counterparts, but the type-I and type-II titanium plates had significantly shorter fatigue lives. All F1314 plate types had longer fatigue lives than the type-III titanium plates. The FEA showed minimal stress difference (0.4%) between types II and III, but the stress for types II and III was lower (11.9% and 12.4%) than that for type I. The screw threads did not cause stress concentration in the locking plates in FEA, but may have jeopardized the fatigue strength, especially in the notch-sensitive titanium plates. Improvement to the locking plate design is necessary. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Microchannel plate streak camera

    Science.gov (United States)

    Wang, Ching L.

    1989-01-01

    An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras. The improved streak camera is far more sensitive to photons (UV to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1000 KeV x-rays.

  10. Electronic Equipment Cold Plates

    Science.gov (United States)

    1976-04-01

    equations for such a flow regiae. For laainar flow and Moderate teaperature differwwe« between the well «nd coolant, a aodifled Sieder -Tate...con- figuration. The heat-transfer coefficients, therefore, were determined by using both the Sieder -Tate and McAdams equations and the coaputed...values used In the analytical predictions. As with th* previous cold Plates, the Sieder -Tate equation gave too low of values for the heat- transfer

  11. Elastic plate spallation

    Science.gov (United States)

    Oline, L.; Medaglia, J.

    1972-01-01

    The dynamic finite element method was used to investigate elastic stress waves in a plate. Strain displacement and stress strain relations are discussed along with the stiffness and mass matrix. The results of studying point load, and distributed load over small, intermediate, and large radii are reported. The derivation of finite element matrices, and the derivation of lumped and consistent matrices for one dimensional problems with Laplace transfer solutions are included. The computer program JMMSPALL is also included.

  12. Plate Tearing by a Cone

    DEFF Research Database (Denmark)

    Simonsen, Bo Cerup

    1997-01-01

    The present paper is concerned with steady-state plate tearing by a cone. This is a scenario where a cone is forced through a ductile metal plate with a constant lateral tip penetration in a motion in the plane of the plate. The considered process could be an idealisaton of the damage, which...

  13. Plate Tearing by a Cone

    DEFF Research Database (Denmark)

    Simonsen, Bo Cerup

    1998-01-01

    The present paper is concerned with steady-state plate tearing by a cone. This is a scenario where a cone is forced through a ductile metal plate with a constant lateral tip penetration in a motion in the plane of the plate. The considered process could be an idealisation of the damage, which...

  14. Imaging plates calibration to X-rays

    Science.gov (United States)

    Curcio, A.; Andreoli, P.; Cipriani, M.; Claps, G.; Consoli, F.; Cristofari, G.; De Angelis, R.; Giulietti, D.; Ingenito, F.; Pacella, D.

    2016-05-01

    The growing interest for the Imaging Plates, due to their high sensitivity range and versatility, has induced, in the last years, to detailed characterizations of their response function in different energy ranges and kind of radiation/particles. A calibration of the Imaging Plates BAS-MS, BAS-SR, BAS-TR has been performed at the ENEA-Frascati labs by exploiting the X-ray fluorescence of different targets (Ca, Cu, Pb, Mo, I, Ta) and the radioactivity of a BaCs source, in order to cover the X-ray range between few keV to 80 keV.

  15. Motion of the Scotia sea plates

    Science.gov (United States)

    Thomas, C.; Livermore, R.; Pollitz, F.

    2003-01-01

    Earthquake data from the Scotia Arc to early 2002 are reviewed in the light of satellite gravity and other data in order to derive a model for the motion of plates in the Scotia Sea region. Events with magnitude ???5, which occurred on or near the boundaries of the Scotia and Sandwich plates, and for which Centroid Moment Tensor (CMT) solutions are available, are examined. The newer data fill some of the previous sampling gaps along the boundaries of the Scotia and Sandwich plates, and provide tighter constraints on relative motions. Variations in the width of the Brunhes anomaly on evenly spaced marine magnetic profiles over the East Scotia Ridge provide new estimates of Scotia-Sandwich plate spreading rates. Since there are no stable fracture zones in the east Scotia Sea, the mean azimuth of sea floor fabric mapped by sidescan is used to constrain the direction of spreading. 18 new rate estimates and four azimuths from the East Scotia Ridge are combined with 68 selected earthquake slip vectors from the boundaries of the Scotia Sea in a least-squares inversion for the best-fitting set of Euler poles and angular rotation rates describing the 'present-day' motions of the Scotia and Sandwich plates relative to South America and Antarctica. Our preferred model (TLP2003) gives poles that are similar to previous estimates, except for Scotia Plate motion with respect to South America, which is significantly different from earlier estimates; predicted rates of motion also differ slightly. Our results are much more robust than earlier work. We examine the implications of the model for motion and deformation along the various plate boundaries, with particular reference to the North and South Scotia Ridges, where rates are obtained by closure.

  16. Computational investigations of mechanical failures of internal plate fixation.

    Science.gov (United States)

    Chen, G; Schmutz, B; Wullschleger, M; Pearcy, M J; Schuetz, M A

    2010-01-01

    This paper investigated the biomechanics of two clinical cases of bone fracture treatments. Both fractures were treated with the same locking compression plate but with different numbers of screws as well as different plate materials. The fracture treated with 12 screws (rigid fixation) failed at 7 weeks with the plate breaking; the fracture with six screws (flexible fixation) endured the entire healing process. It was hypothesized that the plate failure in the unsuccessful case was due to the material fatigue induced by stress concentration in the plate. As the two clinical cases had different fracture locations and different plate materials, finite element simulations were undertaken for each fractured bone fixed by both a rigid and a flexible method. This enabled comparisons to be made between the rigid and flexible fixation methods. The fatigue life was assessed for each fixation method. The results showed that the stress in the rigid fixation methods could be significantly higher than that in flexible fixation methods. The fatigue analyses showed that, with the stress level in flexible fixation (i.e. with fewer screws), the plate was able to endure 2000 days, and that the plate in rigid fixation could fail by fatigue fracture in 20 days. The paper concludes that the rigid fixation method resulted in serious stress concentrations in the plate, which induced fatigue failure. The flexible fixation gave sufficient stability and was better for fracture healing.

  17. CAD-CAM plates versus conventional fixation plates for primary mandibular reconstruction: A biomechanical in vitro analysis.

    Science.gov (United States)

    Rendenbach, Carsten; Sellenschloh, Kay; Gerbig, Lucca; Morlock, Michael M; Beck-Broichsitter, Benedicta; Smeets, Ralf; Heiland, Max; Huber, Gerd; Hanken, Henning

    2017-09-01

    CAD/CAM reconstruction plates have become a viable option for mandible reconstruction. The aim of this study was to determine whether CAD/CAM plates provide higher fatigue strength compared with conventional fixation systems. 1.0 mm miniplates, 2.0 mm conventional locking plates (DePuy Synthes, Umkirch, Germany), and 2.0 mm CAD/CAM plates (Materialise, Leuven, Belgium/DePuy Synthes) were used to reconstruct a polyurethane mandible model (Synbone, Malans, CH) with cortical and cancellous bone equivalents. Mastication was simulated via cyclic dynamic testing using a universal testing machine (MTS, Bionix, Eden Prairie, MN, USA) until material failure reached a rate of 1 Hz with increasing loads on the left side. No significant difference was found between the groups until a load of 300 N. At higher loads, vertical displacement differed increasingly, with a poorer performance of miniplates (p = 0.04). Plate breakage occurred in miniplates and conventional locking plates. Screw breakage was recorded as the primary failure mechanism in CAD/CAM plates. Stiffness was significantly higher with the CAD/CAM plates (p = 0.04). CAD/CAM plates and reconstruction plates provide higher fatigue strength than miniplates, and stiffness is highest in CAD/CAM systems. All tested fixation methods seem sufficiently stable for mandible reconstruction. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  18. Petroleum and natural gas geology and plate tectonics

    Energy Technology Data Exchange (ETDEWEB)

    Koebel, B.

    1984-01-01

    Several processes of oil and gas geology are studied in connection with plate-tectonical processes. Thus it becomes clear, that there is a distinct difference between the Paleozoic development of the European plate and the Mesozoic development. One can state, that the Paleozoic development is essentially influenced by the positions of the mobile belts and the cratonized parts of the plates. The development during Meso-Caenozoic is mainly characterized by crustal processes in the result of the disintegration of Pangaea.

  19. Oblique Impact of Projectile on Thin Aluminium Plates

    Directory of Open Access Journals (Sweden)

    W.U. Khan

    2003-04-01

    Full Text Available Experiments were performed, wherein cylindrical projectiles made of hardened steel were impacted on commercially available aluminium plates at different angles. Projectiles were of 12.8 mm diameter and plates were of 0.81 mm, 1.52mm and 1.91mm thicknesses. Based on the experimental results, an analytical model has been developed to predict the residual velocity of the projectile and the ballistic limit of the plate.

  20. Empirical Analysis Based on Governance and Performance in SmaU and Medium Plate Companies of Different Nature of Ownership%基于不同所有权性质的中小板公司治理与绩效的实证分析

    Institute of Scientific and Technical Information of China (English)

    王珍

    2012-01-01

    According to the governance and performance characteristics and shortcomings of existing research of small and medium plate companies, this essay takes a partial correlation analysis method to reflect the small and medium plate companies' consolidated performance indicators, comparing corporate governance' impact of different ownership on its performance to arrive at measures of perfecting small and medium plate companies' governance.%根据中小板公司治理与绩效关系的特征和现有研究的缺陷,采用偏相关分析方法,比较不同所有权性质的企业治理特征对其绩效影响的差异,并提出完善中小板公司治理的对策。

  1. Plate tectonics conserves angular momentum

    Directory of Open Access Journals (Sweden)

    C. Bowin

    2009-03-01

    Full Text Available A new combined understanding of plate tectonics, Earth internal structure, and the role of impulse in deformation of the Earth's crust is presented. Plate accelerations and decelerations have been revealed by iterative filtering of the quaternion history for the Euler poles that define absolute plate motion history for the past 68 million years, and provide an unprecedented precision for plate angular rotation variations with time at 2-million year intervals. Stage poles represent the angular rotation of a plate's motion between adjacent Euler poles, and from which the maximum velocity vector for a plate can be determined. The consistent maximum velocity variations, in turn, yield consistent estimates of plate accelerations and decelerations. The fact that the Pacific plate was shown to accelerate and decelerate, implied that conservation of plate tectonic angular momentum must be globally conserved, and that is confirmed by the results shown here (total angular momentum ~1.4 E+27 kgm2s−1. Accordingly, if a plate decelerates, other plates must increase their angular momentums to compensate. In addition, the azimuth of the maximum velocity vectors yields clues as to why the "bend" in the Emperor-Hawaiian seamount trend occurred near 46 Myr. This report summarizes processing results for 12 of the 14 major tectonic plates of the Earth (except for the Juan de Fuca and Philippine plates. Plate accelerations support the contention that plate tectonics is a product of torques that most likely are sustained by the sinking of positive density anomalies due to phase changes in subducted gabbroic lithosphere at depth in the upper lower mantle (above 1200 km depth. The tectonic plates are pulled along by the sinking of these positive mass anomalies, rather than moving at near constant velocity on the crests of convection cells driven by rising heat. These results imply that spreading centers are primarily passive reactive

  2. Vehicle License Plate Recognition Syst

    Directory of Open Access Journals (Sweden)

    Meenakshi,R. B. Dubey

    2012-12-01

    Full Text Available The vehicle license plate recognition system has greater efficiency for vehicle monitoring in automatic zone access control. This Plate recognition system will avoid special tags, since all vehicles possess a unique registration number plate. A number of techniques have been used for car plate characters recognition. This system uses neural network character recognition and pattern matching of characters as two character recognition techniques. In this approach multilayer feed-forward back-propagation algorithm is used. The performance of the proposed algorithm has been tested on several car plates and provides very satisfactory results.

  3. Accuracy of distal radius positioning using an anatomical plate.

    Science.gov (United States)

    Vroemen, Joy C; Dobbe, Johannes G G; Sierevelt, Inger N; Strackee, Simon D; Streekstra, Geert J

    2013-04-01

    Over the past decade, several anatomical plates have been introduced to improve the result of open reduction and internal fixation of the distal radius. Using 3-dimensional imaging techniques, the authors studied the accuracy and reproducibility of distal radius positioning using anatomical plates.Distal radius fractures and the correction of these fractures were simulated with plastic bone models of radii. The authors simulated a defect by removing an arbitrary wedge shape from the artificial radii. Two surgeons corrected these fractures by placing 2 anatomical plate types according to the plate manufacturers' instructions. The residual positioning errors of the distal segment in relation to the unaffected radii were determined using 3-dimensional imaging and were compared with naturally occurring bilateral radius differences in healthy individuals. In many cases, positioning does not agree with differences based on bilateral asymmetry in healthy patients.This study indicated the accuracy of anatomical plates. Positioning an anatomical plate may lead to considerable residual errors in individual patients. Volar distal radius plate shapes differ among plate manufacturers. Therefore, one plate may perform better than another in an individual.

  4. Large Deflections of Elastic Rectangular Plates

    Science.gov (United States)

    Razdolsky, A. G.

    2015-11-01

    It is known that elastic large deflections of thin plates are governed by von Karman nonlinear equations. The analytical solution of these equations in the general case is unfeasible. Samuel Levy, in 1942, showed that large deflections of the rectangular plate can be expressed as a double series of sine-shaped harmonics (deflection harmonics). However, this method gave no way of creating the computer algorithm of solving the problem. The stress function expression taken in the Levy's method must be revised to find the approach that takes into account of all possible products of deflection coefficients. The algorithm of solving the problem for the rectangular plate with an arbitrary aspect ratio under the action of the lateral distributed load is reported in this paper. The approximation of the plate deflection is taken in the form of double series proposed by Samuel Levy. However, the expression for the stress function is presented in the form that incorporates products of deflection coefficients in the explicit form in distinction to the Levy's expression. The number of harmonics in the deflection expression may be arbitrary. The algorithm provides composing the system of governing cubic equations, which includes the deflection coefficients in the explicit form. Solving the equation system is based on using the principle of minimum potential energy. A method of the gradient descent is applied to find the equilibrium state of the plate as the minimum point of the potential energy. A computer program is developed on the basis of the present algorithm. Numerical examples carried out for the plate model with 16 deflection harmonics illustrate the potentialities of the program. The results of solving the examples are presented in the graphical form for the plates with a different aspect ratio and may be used under designing thin-walled elements of airplane and ship structures.

  5. Real Plates and Dubious Microplates

    Science.gov (United States)

    Kogan, M. G.; Steblov, G. M.

    2008-12-01

    From the onset of plate tectonics, the existence of most of the plates was never put in doubt, although the boundaries of some plates, like Africa, were later revised. There are however, two microplates in northeast Asia, the Amurian and Okhotsk, whose existence and the sense of rotation was revised several times. The rms value of plate-residual GPS velocities is 0.5-0.9 mm/a for sets of stations representing the motion of the following plates: Antarctic, Australian, Eurasian, North American, Nubian, Pacific, and South American. This value can be regarded as an upper bound on deviation of real plates from infinite stiffness. The rms value of plate-residual GPS velocities is 1.2-1.8 mm/a for the Indian, Nazca, and Somalian plates. Higher rms values for India and Nazca are attributed to the noisier data. The higher rms value for Somalia appears to arise from the distributed deformation to the east of the East African Rift; whether this statement is true can only be decided from observations of denser network in the future. From the analysis of plate-residual GPS velocities, the Canadian Arctic and northeastern Siberia belong to the North American plate. The detailed GPS survey on Sakhalin Island shows that the Sea of Okhotsk region also belongs to the North American plate while the region to the west of it belongs to the Eurasian plate. These results provide a constraint on the geometry of the North American plate and put in doubt the existence of smaller plates in northeast Asia.

  6. Smaller plates, less food waste

    DEFF Research Database (Denmark)

    Hansen, Pelle Guldborg; Schmidt, Karsten; Skov, Laurits Rhoden

    With roughly one-third of food produced for human consumption lost or wasted globally (about 1.3 billion tons per year), the impact on the environment cannot be anymore neglected. Actions at all points in the production chain are now urgent, including reductions in food waste at home, by retailer...... the hypothesis that dishware size plays an important role in the amount of food wasted among Danish adults in a self-service eating setting. This finding has PHN implications: slight changes in the foodscape can contribute to sustainable food consumption goals....... was to investigate whether the size of the dishware would non-reflectively influence the amount of foods taken from an “ad-libitum” buffet and the resulting amount of waste. Sample consisted of Danish business leaders that took part in a congress in Copenhagen, Denmark. Two buffet tables were set up on two separate....... All food waste was collected in designated trash bags (different colour in each floor) and weighted in bulk by students. Smaller plates appear to have decreased food waste by 26% compared to the standard sized plates at a single serving in a self-service eating setting. This pilot study supports...

  7. Interplay between geometry and temperature for inclined Casimir plates

    CERN Document Server

    Weber, Alexej

    2009-01-01

    We provide further evidence for the nontrivial interplay between geometry and temperature in the Casimir effect. We investigate the temperature dependence of the Casimir force between an inclined semi-infinite plate above an infinite plate in D dimensions using the worldline formalism. Whereas the high-temperature behavior is always found to be linear in T in accordance with dimensional-reduction arguments, different power-law behaviors at small temperatures emerge. Unlike the case of infinite parallel plates, which shows the well-known T^D behavior of the force, we find a T^{D-1} behavior for inclined plates, and a ~T^{D-0.3} behavior for the edge effect in the limit where the plates become parallel. The strongest temperature dependence ~T^{D-2} occurs for the Casimir torque of inclined plates. Numerical as well as analytical worldline results are presented.

  8. Modeling of plates with multiple anisotropic layers and residual stress

    DEFF Research Database (Denmark)

    Engholm, Mathias; Pedersen, Thomas; Thomsen, Erik Vilain

    2016-01-01

    Usually the analytical approach for modeling of plates uses the single layer plate equation to obtain the deflection and does not take anisotropy and residual stress into account. Based on the stress–strain relation of each layer and balancing stress resultants and bending moments, a general...... multilayered anisotropic plate equation is developed for plates with an arbitrary number of layers. The exact deflection profile is calculated for a circular clamped plate of anisotropic materials with residual bi-axial stress.From the deflection shape the critical stress for buckling is calculated......, and an excellent agreement between the two models is seen with a relative difference of less than 2% for all calculations. The model was also used to extract the cell capacitance, the parasitic capacitance and the residual stress of a pressure sensor composed of a multilayered plate of silicon and silicon oxide...

  9. LARGE AMPLITUDE FREE VIBRATIONS OF LAMINATED COMPOSITE PLATES

    Institute of Scientific and Technical Information of China (English)

    Wang Haowen; Gao Zheng; Zheng Zhaochang

    2000-01-01

    This paper deals with large amplitude free flexural vibrations of laminated composite plates using a 9-node Heterosis degenerated isoparametric quadrilateral element, including the effects of transverse shear and rotary inertia. The nonlinear dynamic equations of the plates are formulated in von Karman's sense. Amplitude-frequemcy relationships are obtained through dynamic response history using the Newmark numerical integration scheme. Detailed numerical results based on various parameters are presented for orthotropic laminated plates with different boundary conditions. The rectangular anti-symmetric cross-ply plates show the softening type of nonlinearity for initial small amplitudes. The displacement amplitudes decrease and nonlinear frequencies increase with the increment of time.

  10. Modeling and Simulation of Nonlinear Micro-electromechanical Circular Plate

    Directory of Open Access Journals (Sweden)

    Chin-Chia Liu

    2013-09-01

    Full Text Available In the present study, the hybrid differential transformation and finite difference method is applied to analyze the dynamic behavior of the nonlinear micro-electromechanical circular plate actuated by combined DC / AC loading schemes. The analysis takes account of the axial residual stress and hydrostatic pressure acting on micro circular plate upper surface. The dynamic response of the plate as a function of the magnitude of the AC driving voltage is explored. Moreover, the effect of the initial gap height on the pull-in voltage of the plate is systematically explored.

  11. GENERALIZED VARIATIONAL PRINCIPLESFOR VISCOELASTIC THIN AND THICK PLATES WITH DAMAGE

    Institute of Scientific and Technical Information of China (English)

    ShengDongfa; ChengChangjun

    2004-01-01

    From the constitutive model with generalized force fields for a viscoelastic body with damage, the differential equations of motion for thin and thick plates with damage are derived under arbitrary boundary conditions. The convolution-type functionals for the bending of viscoelastic thin and thick plates with damage are presented, and the corresponding generalized variational principles are given. From these generalized principles, all the basic equations of the displacement and damage variables and initial and boundary conditions can be deduced. As an example, we compare the difference between the dynamical properties of plates with and without damage and consider the effect of damage on the dynamical properties of plates.

  12. ANALYTICAL COMPARISION OF DISC BRAKES WITH LINEAR AND CURVED SHAPED SLOTS BETWEEN PLATES FOR STRUCTURAL ANALYSIS ON DIFFERENT PARAMETER USING THROUGH CATIA V5 R20 AND ANSYS 15.0.7

    OpenAIRE

    Vivek Kumar*, Anshuka Srivastava

    2016-01-01

    The process which converts the kinetic energy of the vehicle into mechanical energy is known as Braking, which must be dissipated in the form of heat. The device using for decelerating or stopping the rotation of a wheel is called as disc brake. A brake disc (or rotor) usually made of linear shaped slots between plates and a disc brake ( or rotor) usually made of curved shaped slots between plates having materials used in both is Structural Steel, is connected to the wheel and/or the axle. Fr...

  13. Plate Full of Color

    Centers for Disease Control (CDC) Podcasts

    2008-08-04

    The Eagle Books are a series of four books that are brought to life by wise animal characters - Mr. Eagle, Miss Rabbit, and Coyote - who engage Rain That Dances and his young friends in the joy of physical activity, eating healthy foods, and learning from their elders about health and diabetes prevention. Plate Full of Color teaches the value of eating a variety of colorful and healthy foods.  Created: 8/4/2008 by National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP).   Date Released: 8/5/2008.

  14. Dynamics of Tectonic Plates

    CERN Document Server

    Pechersky, E; Sadowski, G; Yambartsev, A

    2014-01-01

    We suggest a model that describes a mutual dynamic of tectonic plates. The dynamic is a sort of stick-slip one which is modeled by a Markov random process. The process defines a microlevel of the dynamic. A macrolevel is obtained by a scaling limit which leads to a system of integro-differential equations which determines a kind of mean field systems. Conditions when Gutenberg-Richter empirical law are presented on the mean field level. These conditions are rather universal and do not depend on features of resistant forces.

  15. Dynamics of Tectonic Plates

    OpenAIRE

    2014-01-01

    We suggest a model that describes a mutual dynamic of tectonic plates. The dynamic is a sort of stick-slip one which is modeled by a Markov random process. The process defines a microlevel of the dynamic. A macrolevel is obtained by a scaling limit which leads to a system of integro-differential equations which determines a kind of mean field systems. Conditions when Gutenberg-Richter empirical law are presented on the mean field level. These conditions are rather universal and do not depend ...

  16. Closed-form solution for free vibration of piezoelectric coupled annular plates using Levinson plate theory

    Science.gov (United States)

    Hosseini Hashemi, Sh.; Es'haghi, M.; Karimi, M.

    2010-04-01

    Free vibration analysis of annular moderately thick plates integrated with piezoelectric layers is investigated in this study for different combinations of soft simply supported, hard simply supported and clamped boundary conditions at the inner and outer edges of the annular plate on the basis of the Levinson plate theory (LPT). The distribution of electric potential along the thickness direction in the piezoelectric layer is assumed as a sinusoidal function so that the Maxwell static electricity equation is approximately satisfied. The differential equations of motion are solved analytically for various boundary conditions of the plate. In this study the closed-form solution for characteristic equations, displacement components of the plate and electric potential are derived for the first time in the literature. To demonstrate the accuracy of the present solution, comparison studies is first carried out with the available data in the literature and then natural frequencies of the piezoelectric coupled annular plate are presented for different thickness-radius ratios, inner-outer radius ratios, thickness of piezoelectric, material of piezoelectric and boundary conditions. Present analytical model provides design reference for piezoelectric material application, such as sensors, actuators and ultrasonic motors.

  17. Structure of colloidal sphere-plate mixtures

    Science.gov (United States)

    Doshi, N.; Cinacchi, G.; van Duijneveldt, J. S.; Cosgrove, T.; Prescott, S. W.; Grillo, I.; Phipps, J.; Gittins, D. I.

    2011-05-01

    In addition to containing spherical pigment particles, coatings usually contain plate-like clay particles. It is thought that these improve the opacity of the paint film by providing an efficient spacing of the pigment particles. This observation is counterintuitive, as suspensions of particles of different shapes and sizes tend to phase separate on increase of concentration. In order to clarify this matter a model colloidal system is studied here, with a sphere-plate diameter ratio similar to that found in paints. For dilute suspensions, small angle neutron scattering revealed that the addition of plates leads to enhanced density fluctuations of the spheres, in agreement with new theoretical predictions. On increasing the total colloid concentration the plates and spheres phase separate due to the disparity in their shape. This is in agreement with previous theoretical and experimental work on colloidal sphere-plate mixtures, where one particle acts as a depleting agent. The fact that no large scale phase separation is observed in coatings is ascribed to dynamic arrest in intimately mixed, or possibly micro-phase separated structures, at elevated concentration.

  18. Structure of colloidal sphere-plate mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Doshi, N; Cinacchi, G; Van Duijneveldt, J S; Cosgrove, T; Prescott, S W [School of Chemistry, University of Bristol, Bristol BS8 1TS (United Kingdom); Grillo, I [Institut Laue-Langevin, 6 rue Jules Horowitz BP 156, 38042 Grenoble Cedex 9 (France); Phipps, J [Imerys Minerals Ltd, Par Moor Centre, Par Moor Road, Par, Cornwall PL24 2SQ (United Kingdom); Gittins, D I, E-mail: Giorgio.Cinacchi@bristol.ac.uk, E-mail: J.S.van-Duijneveldt@bristol.ac.uk [Imerys Performance and Filtration Minerals Ltd, 130 Castilian Drive, Goleta, CA 93117 (United States)

    2011-05-18

    In addition to containing spherical pigment particles, coatings usually contain plate-like clay particles. It is thought that these improve the opacity of the paint film by providing an efficient spacing of the pigment particles. This observation is counterintuitive, as suspensions of particles of different shapes and sizes tend to phase separate on increase of concentration. In order to clarify this matter a model colloidal system is studied here, with a sphere-plate diameter ratio similar to that found in paints. For dilute suspensions, small angle neutron scattering revealed that the addition of plates leads to enhanced density fluctuations of the spheres, in agreement with new theoretical predictions. On increasing the total colloid concentration the plates and spheres phase separate due to the disparity in their shape. This is in agreement with previous theoretical and experimental work on colloidal sphere-plate mixtures, where one particle acts as a depleting agent. The fact that no large scale phase separation is observed in coatings is ascribed to dynamic arrest in intimately mixed, or possibly micro-phase separated structures, at elevated concentration.

  19. Automatic Digital Plate Reading for Surveillance Cultures.

    Science.gov (United States)

    Kirn, Thomas J

    2016-10-01

    The automation of specimen processing and culture workup has rapidly emerged in clinical microbiology laboratories throughout the world and more recently in the United States. While many U.S. laboratories have implemented some form of automated specimen processing and some have begun performing digital plate reading, automated colony analysis is just beginning to be utilized clinically. In this issue of the Journal of Clinical Microbiology, M. L. Faron et al. (J Clin Microbiol 54:2470-2475, 2016, http://dx.doi.org/10.1128/JCM.01040-16) report the results of their evaluation of the performance of the WASPLab Chromogenic Detection Module (CDM) for categorizing chromogenic agar plates as negative or "nonnegative" for vancomycin-resistant enterococci (VRE). Their major finding was 100% sensitivity for detection of "nonnegative" specimens using CDM compared to manual methods for specimens plated on two different types of VRE chromogenic agar plates. Additionally, utilization of digital plate reading in conjunction with automated colony analysis was predicted to result in significant savings based on greatly reduced labor costs. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  20. Finite Element Analysis of Reinforced Concrete Plate Impacted by Block

    Institute of Scientific and Technical Information of China (English)

    LUO Xiaoyang; Pascal PERROTIN; YAN Quansheng

    2006-01-01

    A new concept of structurally dissipating rock-shed (SDR) was developed by the lab of Tonello IC and LOCIE-ESIGEC (France).To decide the dimension of the plate used in SDR,an ANSYS model which could simulate the impact of rock in the centre of the plate was established by Fabien Delhomme.By using this model,some finite element analyses are carried out in the present paper Firstly,a plate impacted by a block is numerically simulated,the numerical results obtained from different mesh sizes are compared and the accuracy of the finite element model is verified.Then,the dynamic response of the plate impacted at the boundary and in the medium part is computed.By analyzing the stress in rebar,the most dangerous region of impact of plate was found.For a rectangular plate,the most dangerous region is at the corner of the plate when a block drops in.Finally,the whole deformation process of the plate under dropping block was simulated and a simplified definition (effect zone) to describe the deformation process in different positions of plate was given.From this study,it is found that the impact only affects heavily within the effect zone.

  1. Evaluating Picture Quality of Image Plates in Digital CR Systems

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Byung Joon [Dept. of Radiological Tecnology, Choonhae College of Health Science, Ulsan (Korea, Republic of); Ji Tae Jeong [Dept. of Radiological Science, Kaya University, Kimhae (Korea, Republic of)

    2011-12-15

    Lab effectively supplemented the effects of outside radiation on image plates in the process of image acquisition of CR (computed radiography) systems and conducted for effective utilization in the case of clinical application. For this, Lab classified the storage places and time periods of image plates and compared and analyzed the differences between small dark spots. Lab also assessed the concentration distribution within the boundaries of images. Lab compared and measured the number of dark spots in a light room and a dark room depending on the storage places of image plates and found that dark spots slightly increased in an image plate when stored in a light room on the first and second days. Dark spots increased in proportion to the length of time stored. In the case of the image plate stored in a dark room, the number of dark spots remarkably decreased. With regard to picture quality as related to the location of image plates, the damage to picture quality could be reduced by locating regions of interest in the center. With regard to differences in sharpness following changes in the thickness of subjects, fewer scatter rays occurred and sharpness improved by reducing the thickness of subjects as much as possible. To get medical images of excellent quality, image plates should be managed effectively and it is desirable to keep images plates in dark iron plate boxes and not to expose them to outside radiation for a long time.

  2. Dynamic buckling of stiffened plates subjected to explosion impact loads

    Science.gov (United States)

    Wang, J.; Guo, J.; Yao, X. L.; Zhang, A. M.

    2017-01-01

    The dynamic buckling characteristics and criteria of a ship's structural stiffened plate subjected to underwater explosion impact loads are investigated in this study. Using the structural deformations observed in the experiments of underwater explosions against a plated grillage model, the mode shapes of the dynamic buckling were obtained. Through the construction of a computational model of stiffened plates subjected to an underwater explosion shock wave, the impact load was theoretically calculated and transformed into a rectangular pulse. According to the different response patterns of stiffened plates under different impact loads, a dynamic buckling criterion for the stiffened plates subjected to an explosion shock wave was proposed. Additionally, the static buckling phenomenon in the stiffened plates was analysed based on the minimum excess principle. In combination with the dynamic buckling criterion, the effects of various stiffening configurations on the dynamic and static buckling loads are discussed. The calculation results show that when the equivalent rectangular pulse is 2-3 times that of the static buckling load, the responses of the stiffened plates under the original shock load and the equivalent rectangular pulse are virtually identical. The impact load amplitude is the primary influencing factor in the dynamic buckling of stiffened plates subjected to underwater explosive impact loads. The stiffened plate aspect ratio has a substantial influence on the dynamic load factor. The analytical method and results are presented, which can be used to design stiffened optimum hull structures to enhance the dynamic load carrying capacity to withstand underwater shock damage.

  3. Numerical analysis of cross shear plate rolling

    DEFF Research Database (Denmark)

    Zhang, Wenqi; Bay, Niels

    1997-01-01

    The rolling process is widely applied for industrial production of metal plates. In conventional plate rolling the two work rolls are rotating at the same peripheral speed. By introducing a specific difference in the speed of the two work rolls, cross shear rolling is introduced forming a central...... shear zone between the forward and backward slip zones in the deformation zone thus lowering the rolling load. A numerical analysis of the cross shear rolling process is carried out based on the slab method adopting Wanheim and Bay's general friction model. The pressure distribution along the contact...

  4. Augmentation plating in hypertrophic non-union after nail fixation of femoral shaft fracture compared with exchange plating

    Institute of Scientific and Technical Information of China (English)

    Jiang Liangjun; Pan Zhijun; Zheng Qiang

    2014-01-01

    Background Augmentation plating has been used successfully to treat hypertrophic non-union after nail fixation.This study compared the efficacy of augmentation plating and exchange plating for treating hypertrophic non-union of femoral shaft fracture after intramedullary nail fixation.Methods A total of 12 patients received augmentation plating and 15 patients received exchange plating as treatment for femoral shaft hypertrophic non-union.The procedures were conducted at our medical centre between January 2005and January 2012.Clinical follow-up was conducted at 2 weeks,1 month and then monthly until union was achieved to compare union time,operation time,bleeding and complications between the two groups.Results All patients underwent follow-up examinations until fracture union was achieved.The average length of followup time after the second treatment was (18.37±3.28) months.The time needed for union was (4.17±0.94) months in the augmentation plating group and (5.33±1.72) months in the exchange plating group.The operation time was (90.00±17.58) minutes in the augmentation plating group and (160.00±25.35) minutes in the exchange plating group.The amount of blood loss during the operation was (270.00±43.32) ml in the augmentation plating group and (530.00±103.65) ml in the exchange plating group.Both groups showed significant difference (P <0.05) in their results.No complications were reported after the second operation.Conclusions Augmentation plating after nail fixation could remove local rotation instability,facilitate simple operation,create minimal damage and enable exercise for early functional recovery.Therefore,augmentation plating is excellent for treating hypertrophic non-union after nail fixation in femoral shaft fracture.

  5. Analyzing the effects of size of hole on Plate failure

    Energy Technology Data Exchange (ETDEWEB)

    Behzad, Mohammadzadeh; Noh, Hyukchun [Sejong Univ., Seoul (Korea, Republic of)

    2013-05-15

    The load at critical point in which an infinitesimal increase in load can make the plate to buckle, is buckling load. When a plate element is subjected to direct compression, bending, shear, or a combination of these stresses in its plane, the plate may buckle locally before the member as a whole becomes unstable or before the yield stress of the material is reached. Holes can either increase or decrease critical load of a plate depending on its position and geometry. The presence of holes in plates will change the strength and stiffness, so the amounts of stress and its distribution which induce strain and buckling will be changed. This study deals with studying the buckling of plate with holes using finite element method(FEM). Buckling is one of the main reasons for steel members to fail during service life time. As plates are frequently used in the structures of nuclear power plants and in some cases making holes in plates is necessary, it is necessary to assay the capacity of the plates especially in terms of buckling. FEM is a useful approach which makes the plate analysis be performed with ease. This study relates the buckling load of plates with through-thickness holes to a dimensionless parameter (D/a). By increasing D/a ratio, the amount of plate strength is observed to be decreased. After D/a=0.5, the rate of decreasing is observed to be increased drastically. Therefore, it is better to use ratio D/a less than or equal to 0.5. As a further study, it is possible to investigate other aspects such as different thickness, different positions and so on.

  6. Resistive Plate Chamber Efficiency & Rate Capability Analysis

    Science.gov (United States)

    Candocia, Max

    2012-10-01

    Bakelite-based resistive plate chambers (RPCs) are particle detectors commonly used in muon trigger systems for high-energy physics experiments. Bakelite RPCs combine fast response, sufficient position resolution and low cost, and they can be operated at instantaneous background rates up to approximately 1.5 kHz/cm^2. Current and future collider experiments will demand operation of trigger RPCs under background rates higher than what is currently achieved. The rate capability is related to the bulk and surface conductivities of the Bakelite material used for the plates bordering the active gas volume in the RPCs. At the LHC and RHIC, these surfaces are coated with linseed oil, which lowers the surface resistivity of the Bakelite, which, to a point, improves the rate capability of the detectors. We have doped our own plates with various concentrations of carbon black. Over the past year we have tested RPCs with Bakelite plates of different resistivity using cosmic ray muons and radioactive Fe55 sources to emulate different levels of background in the detector. Results on the RPC efficiencies at different background rates and for different Bakelite coatings will be presented.

  7. Korn Inequalities for a Reinforced Plate

    NARCIS (Netherlands)

    Nazarov, S.A.; Slutskij, A.S.; Sweers, G.H.

    2012-01-01

    Asymptotically optimal Korn inequalities are derived for a composite material that consists of two families of stiff rods surrounded by a homogeneous soft material. The composite plate is fixed through the protruding stiff rods only. The asymptotic behaviour is shown to be crucially different for fa

  8. Dual fuel gradients in uranium silicide plates

    Energy Technology Data Exchange (ETDEWEB)

    Pace, B.W. [Babock and Wilcox, Lynchburg, VA (United States)

    1997-08-01

    Babcock & Wilcox has been able to achieve dual gradient plates with good repeatability in small lots of U{sub 3}Si{sub 2} plates. Improvements in homogeneity and other processing parameters and techniques have allowed the development of contoured fuel within the cladding. The most difficult obstacles to overcome have been the ability to evaluate the bidirectional fuel loadings in comparison to the perfect loading model and the different methods of instilling the gradients in the early compact stage. The overriding conclusion is that to control the contour of the fuel, a known relationship between the compact, the frames and final core gradient must exist. Therefore, further development in the creation and control of dual gradients in fuel plates will involve arriving at a plausible gradient requirement and building the correct model between the compact configuration and the final contoured loading requirements.

  9. Caribbean tectonics and relative plate motions

    Science.gov (United States)

    Burke, K.; Dewey, J. F.; Cooper, C.; Mann, P.; Pindell, J. L.

    1984-01-01

    During the last century, three different ways of interpreting the tectonic evolution of the Gulf of Mexico and the Caribbean have been proposed, taking into account the Bailey Willis School of a permanent pre-Jurassic deep sea basin, the Edward Suess School of a subsided continental terrain, and the Alfred Wegener School of continental separation. The present investigation is concerned with an outline of an interpretation which follows that of Pindell and Dewey (1982). An attempt is made to point out ways in which the advanced hypotheses can be tested. The fit of Africa, North America, and South America is considered along with aspects of relative motion between North and South America since the early Jurasic. Attention is given to a framework for reconstructing Caribbean plate evolution, the evolution of the Caribbean, the plate boundary zones of the northern and southern Caribbean, and the active deformation of the Caribbean plate.

  10. Optimum annular focusing by a phase plate

    CERN Document Server

    Arrizón, Victor; Aguirre-Olivas, Dilia; Mellado-Villaseñor, Gabriel

    2015-01-01

    Conventional light focusing, i. e. concentration of an extended optical field within a small area around a point, is a frequently used process in Optics. An important extension to conventional focusing is the generation of the annular focal field of an optical beam. We discuss a simple optical setup that achieves this kind of focusing employing a phase plate as unique optical component. We first establish the class of beams that being transmitted through the phase plate can be focused into an annular field with topological charge of arbitrary integer order q. Then, for each beam in this class we determine the plate transmittance that generates the focal field with the maximum possible peak intensity. In particular, we discuss and implement experimentally the optimum annular focusing of a Gaussian beam. The attributes of optimum annular focal fields, namely the high peak intensity, intensity gradient and narrow annular section, are advantageous for different applications of such structured fields.

  11. Guided-mode resonant wave plates.

    Science.gov (United States)

    Magnusson, Robert; Shokooh-Saremi, Mehrdad; Johnson, Eric G

    2010-07-15

    We introduce half-wave and quarter-wave retarders based on the dispersion properties of guided-mode resonance elements. We design the wave plates using numerical electromagnetic models joined with the particle swarm optimization method. The wave plates operate in reflection. We provide computed results for reflectance and phase in the telecommunication spectral region near 1.55 microm wavelength. A surface-relief grating etched in glass and overcoated with silicon yields a half-wave plate with nearly equal amplitudes of the TE and TM polarization components and pi phase difference across a bandwidth exceeding 50 nm. Wider operational bandwidths are obtainable with more complex designs involving glass substrates and mixed silicon/hafnium dioxide resonant gratings. The results indicate a potential new approach to fashion optical retarders.

  12. Effect of nozzle-to-plate spacing on the development of a plane jet impinging on a heated plate

    Science.gov (United States)

    Rim, Ben Kalifa; Saïd, Nejla Mahjoub; Bournot, Hervé; Le Palec, Georges

    2016-09-01

    An experimental investigation was carried out to study the behavior of a turbulent air jet impinging on a heated plate. The study of the flow field was performed using a particle image velocimetry. A three-dimensional numerical model with Reynolds stress model has been conducted to examine the global flow. Numerical results agree well with experimental data. The main properties of the fluid occurring between the nozzle and the flat plate are presented. In addition, the effect of the distance between the nozzle exit and the plate (h/e = 14 and 28) were investigated and detailed analysis of the dynamic, turbulent distribution and temperature fields were performed. The wall shear stress and the pressure fields near the heated plate are then explored. Results showed that the mean velocity and the heat transfer characteristics of small nozzle-to-plate spacing are significantly different from those of large nozzle-to-plate spacing.

  13. CMS Resistive plate Champers

    CERN Document Server

    Zainab, Karam

    2013-01-01

    There are many types of gas detectors which are used in CERN in LHC project, There is a main parts for the gas detectors which must be in all gas detectors types like Multiwire proportional chambers, such as the micromesh gaseous structure chamber (the MicroMegas), Gas-electron multiplier (GEM) detector, Resistive Plate Champers... Compact Muon Solenoid (CMS) experiment detecting muons which are powerful tool for recognizing signatures of interesting physics processes. The CMS detector uses: drift tube (DT), cathode strip chamber (CSC) and resistive plate chamber (RPC). Building RPC’s was my project in summer student program (hardware). RPC’s have advantages which are triggering detector and Excellent time resolution which reinforce the measurement of the correct beam crossing time. RPC’s Organized in stations :  RPC barrel (RB) there are 4 stations, namely RB1, RB2, RB3, and RB4  While in the RPC endcap (RE) the 3 stations are RE1, RE2, and RE3. In the endcaps a new starion will be added and this...

  14. Stiffness Analysis and Improvement of Bolt-Plate Contact Assemblies

    DEFF Research Database (Denmark)

    Pedersen, Niels Leergaard; Pedersen, Pauli

    2008-01-01

    In a previous study it was shown that, a simplified expression for the stiffness of the plate member in a bolt-plate assembly can be found. The stiffnesses of the bolt and the connected plates are the primary quantities that control the lifetime of a dynamically loaded connection. The present study...... of stiffnesses is extended to include different material parameters by including the influence of Poisson's ratio. Two simple practical formulas are suggested and their accuracies are documented for different bolts and different material (Poisson's ratio). Secondly, the contact analysis between the bolt head...... and the plate is extended by the possibility of designing a gap, that is, a nonuniform distance between the bolt and plate before prestressing. Designing the gap function generates the possibility for a better stress field by which the stiffness of the bolt is lowered, and at the same time the stiffness...

  15. Numerical simulation of seismic performance for different types of steel plate shear walls%不同类型钢板剪力墙抗震性能的数值模拟

    Institute of Scientific and Technical Information of China (English)

    李峰; 王栋; 郭宏超; 吴冠男; 方飞虎

    2011-01-01

    In order to provide theory support for the use of steel plate shear walls in actual engineering, the seismic performance of the thin steel plate shear wall, the cross stiffener steel plate shear wall and the steel plate shear wall with slits, based on experiments, was simulated under the low cycle reciprocating loading via ANSYS and compared with the test data. The hysteresis curve, skeleton curve, the stress and deformation of infill plate were analyzed. The results indicate that the finite element model data agrees well with the experimental ones. The maximum error of yield load is 10. 9% , and that of peak load is only 1.4%. The stress of infill plates gets full development within dividers, while the disabled cross stiffener just gives a weak restraint on the out plane deformation of an infill plate in the later loading period. The local instability below the beam - column joints and column base lead to the failure of the whole structure.%为了给钢板剪力墙在实际工程中的应用提供理论支持,在试验研究的基础上,通过ANSYS模拟了薄钢板、十字加劲及开缝钢板剪力墙在低周往复荷载作用下的抗震性能,并与试验数据进行了对比,分析了滞回曲线、骨架曲线、内填板应力及变形等指标.结果表明:有限元分析与试验数据吻合较好,屈服荷载最大误差为10.9%,峰值荷载最大误差仅为1.4%;加劲肋使得内填板应力在小区格范围内发展更充分,但加载后期,加劲肋失效,对内填板面外约束作用微弱;柱脚和梁柱节点以下部位发生局部屈曲,导致整个结构失效.

  16. Localised Plate Motion on Venus

    Science.gov (United States)

    Ghail, R. C.

    1996-03-01

    The volcanic and tectonic features observed in Dali Vinculum, Parga Vinculum and Imdr Regio are concentrated at long, narrow, curvilinear zones, with relatively minor volcanism and tectonism between these zones. These zones, whilst more diffuse than terrestrial plate boundaries, nevertheless define the margins of tectonic plates. In contrast to Earth, however, it appears that venusian plates are neither created nor destroyed by lateral motion. Rather, plates are thinned and intruded at vincula plate boundaries, vertically accreted by small-scale intra-plate (planitia) volcanism and perhaps destroyed by delamination of thickened crust in tesserae and montane regions such as Thetis Regio and Ishtar Terra. The diversity in age both between and within these three areas together with the evidence for infrequent, small scale resurfacing in the planitiae are difficult to reconcile with a non-uniformitarian geological process.

  17. Tectonics of the Easter plate

    Science.gov (United States)

    Engeln, J. F.; Stein, S.

    1984-01-01

    A new model for the Easter plate is presented in which rift propagation has resulted in the formation of a rigid plate between the propagating and dying ridges. The distribution of earthquakes, eleven new focal mechanisms, and existing bathymetric and magnetic data are used to describe the tectonics of this area. Both the Easter-Nazca and Easter-Pacific Euler poles are sufficiently close to the Easter plate to cause rapid changes in rates and directions of motion along the boundaries. The east and west boundaries are propagating and dying ridges; the southwest boundary is a slow-spreading ridge and the northern boundary is a complex zone of convergent and transform motion. The Easter plate may reflect the tectonics of rift propagation on a large scale, where rigid plate tectonics requires boundary reorientation. Simple schematic models to illustrate the general features and processes which occur at plates resulting from large-scale rift propagation are used.

  18. Tectonics of the Easter plate

    Science.gov (United States)

    Engeln, J. F.; Stein, S.

    1984-01-01

    A new model for the Easter plate is presented in which rift propagation has resulted in the formation of a rigid plate between the propagating and dying ridges. The distribution of earthquakes, eleven new focal mechanisms, and existing bathymetric and magnetic data are used to describe the tectonics of this area. Both the Easter-Nazca and Easter-Pacific Euler poles are sufficiently close to the Easter plate to cause rapid changes in rates and directions of motion along the boundaries. The east and west boundaries are propagating and dying ridges; the southwest boundary is a slow-spreading ridge and the northern boundary is a complex zone of convergent and transform motion. The Easter plate may reflect the tectonics of rift propagation on a large scale, where rigid plate tectonics requires boundary reorientation. Simple schematic models to illustrate the general features and processes which occur at plates resulting from large-scale rift propagation are used.

  19. Aluminum Manganese Molten Salt Plating

    Science.gov (United States)

    2006-06-01

    Dry fixture thoroughly with the air gun. Be especially careful to dry water out of crevices. Note: water is a contaminant to the plating process...easily destroyed if blown with the air. Be especially careful to dry water out of crevices. Note: water is a contaminant to the plating process and...especially careful to dry water out of crevices. 13. Carefully remove part from fixture. If residual plating solution is present at attachments points

  20. Linear optical pulse compression based on temporal zone plates.

    Science.gov (United States)

    Li, Bo; Li, Ming; Lou, Shuqin; Azaña, José

    2013-07-15

    We propose and demonstrate time-domain equivalents of spatial zone plates, namely temporal zone plates, as alternatives to conventional time lenses. Both temporal intensity zone plates, based on intensity-only temporal modulation, and temporal phase zone plates, based on phase-only temporal modulation, are introduced and studied. Temporal zone plates do not exhibit the limiting tradeoff between temporal aperture and frequency bandwidth (temporal resolution) of conventional linear time lenses. As a result, these zone plates can be ideally designed to offer a time-bandwidth product (TBP) as large as desired, practically limited by the achievable temporal modulation bandwidth (limiting the temporal resolution) and the amount of dispersion needed in the target processing systems (limiting the temporal aperture). We numerically and experimentally demonstrate linear optical pulse compression by using temporal zone plates based on linear electro-optic temporal modulation followed by fiber-optics dispersion. In the pulse-compression experiment based on temporal phase zone plates, we achieve a resolution of ~25.5 ps over a temporal aperture of ~5.77 ns, representing an experimental TBP larger than 226 using a phase-modulation amplitude of only ~0.8π rad. We also numerically study the potential of these devices to achieve temporal imaging of optical waveforms and present a comparative analysis on the performance of different temporal intensity and phase zone plates.

  1. A Vehicle License Plate Detection and Recognition System

    Directory of Open Access Journals (Sweden)

    Khalid W. Maglad

    2012-01-01

    Full Text Available Problem statement: Automatic vehicle license plate detection and recognition is a key technique in most of traffic related applications and is an active research topic in the image processing domain. Different methods, techniques and algorithms have been developed for license plate detection and recognitions. Approach: Due to the varying characteristics of the license plate from country to country like numbering system, colors, language of characters, style (font and sizes of license plate, further research is still needed in this area. Results: In most of the Middle East countries, they use the combination of Arabic and English letters, along with their countries logo. Thus, it makes the localization of plate number, the differentiation between Arabic and English letters and logo’s object and finally the recognition of those characters become a more challenging research task. The use of artificial neural network has proved itself beneficial for plate recognition, but it has not been applied for the plate detection. Radial Basis Function (RBF neural network is used both for the detection and recognition of Saudi Arabian license plates. Conclusion/Recommendations: The proposed approach has been tested on 200 front images of national license plate of Saudi Arabia. A higher percentage of accuracy has been obtained to show that the significant of this approach. The study could be further investigated in other Middle East countries.

  2. Glass-bead peen plating

    Science.gov (United States)

    Graves, J. R.

    1974-01-01

    Peen plating of aluminum, copper, and nickel powders was investigated. Only aluminum was plated successfully within the range of peen plating conditions studied. Optimum plating conditions for aluminum were found to be: (1) bead/powder mixture containing 25 to 35% powder by weight, (2) peening intensity of 0.007A as measured by Almen strip, and (3) glass impact bead diameter of at least 297 microns (0.0117 inches) for depositing-100 mesh aluminum powder. No extensive cleaning or substrate preparation is required beyond removing loose dirt or heavy oil.

  3. Intermittent plate tectonics?

    Science.gov (United States)

    Silver, Paul G; Behn, Mark D

    2008-01-04

    Although it is commonly assumed that subduction has operated continuously on Earth without interruption, subduction zones are routinely terminated by ocean closure and supercontinent assembly. Under certain circumstances, this could lead to a dramatic loss of subduction, globally. Closure of a Pacific-type basin, for example, would eliminate most subduction, unless this loss were compensated for by comparable subduction initiation elsewhere. Given the evidence for Pacific-type closure in Earth's past, the absence of a direct mechanism for termination/initiation compensation, and recent data supporting a minimum in subduction flux in the Mesoproterozoic, we hypothesize that dramatic reductions or temporary cessations of subduction have occurred in Earth's history. Such deviations in the continuity of plate tectonics have important consequences for Earth's thermal and continental evolution.

  4. VISAS AND GREEN PLATES

    CERN Multimedia

    2000-01-01

    From 3 April 2000, all questions relating to visa requests for Switzerland, France, or Russia for a member of the personnel must be addressed to Ms. Agnita Querrou (telephone 72838, office 5-2-019, e-mail Agnita.Querrou@cern.ch).The Users' Office continues to deal with requests for letters of invitation and questions concerning visas for users in EP Division.Questions relating to removals, requests for green plates, to privileges of members of the personnel and to the importation of vehicles are still dealt with by Ms Zuzana Miller (telephone 79257, office 33-1-017, e-mail Zuzana.Muller@cern.ch) and Ms Joëlle Belleman (telephone 73962, office 33-1-019, e-mail Joelle.Belleman@cern.ch).

  5. Plate osteosynthesis of simple forearm fractures : LCP versus DC plates

    NARCIS (Netherlands)

    Stevens, Charles Tjerk; Ten Duis, Henk Jan

    2008-01-01

    The aim of this study was to compare the time to radiological bony union of simple A-type fractures of the forearm, treated with either a locking compression plate (LCP) or a dynamic compression plate (DCP). For each fracture, the relation between the use of compression and radiological healing time

  6. Plate osteosynthesis of simple forearm fractures : LCP versus DC plates

    NARCIS (Netherlands)

    Stevens, Charles Tjerk; Ten Duis, Henk Jan

    The aim of this study was to compare the time to radiological bony union of simple A-type fractures of the forearm, treated with either a locking compression plate (LCP) or a dynamic compression plate (DCP). For each fracture, the relation between the use of compression and radiological healing time

  7. Effect of Different Water Supply Modes on Cultivation of Strawberry Seedlings on Plate with Substrate in Shelter%不同给水方式对草莓基质穴盘避雨育苗的影响

    Institute of Scientific and Technical Information of China (English)

    万春雁; 陈雪平; 糜林; 李金凤; 霍恒志

    2012-01-01

    The strawberry seedlings were cultivated on the plate with substrate in shelter, and the influences of different covering modes and drip irrigation strap spacing on substrate moisture content and strawberry seedlings were studied. The results indicated that: in comparison with the treatment of direct drip irrigation without covering ( CK) , the non - woven fabric covering treatment had better effect, the water in the substrate diffused farther and more uniform, and the moisture content in the substrate more than 0. 09 m far from the drip hole was significantly increased by 24% ~ 116%. When the drip irrigation strap spacing was 0. 100 ~0. 175 m, the average moisture content in the substrate was 19. 34% ~ 20. 24% , which could effectively satisfy the normal growth of strawberry seedlings. So the proper drip irrigation strap spacing was 0.125 ~0.175 m in the actual production. The treatment of drip irrigation with the water - pipe spacing of 0. 175 m was better than CK and non -woven fabric covering treatment in seedling ratio, sick seedling ratio and anthrax disease index, while its seedling propagation coefficient was slightly lower than that of the traditional naked - root seedling - raising treatment.%在草莓基质穴盘避雨育苗模式下,研究了不同覆盖方式及滴灌带间距等因子对基质水分含量及草莓子苗的影响,结果表明:无纺布覆盖处理的穴盘与无覆盖物直接滴灌(CK)相比,水分扩散渗透距离远且均匀,离滴孔0.09m以上基质含水量明显提高了24% ~ 116%:滴灌带间距为0.100 ~0.175 m时,基质平均含水量在19.34%~20.24%之间,能有效地满足草莓子苗的正常生长需求,因此实际生产中的滴水管间距宜在0.125~0.175 m之间;滴水管间距为0.175 m处理除繁苗系数略低于传统地面裸根育苗外,其成苗株率、发病株率和炭疽病病情指数均优于对照和基质穴盘无纺布覆盖露地育苗.

  8. Plate tectonics, damage and inheritance.

    Science.gov (United States)

    Bercovici, David; Ricard, Yanick

    2014-04-24

    The initiation of plate tectonics on Earth is a critical event in our planet's history. The time lag between the first proto-subduction (about 4 billion years ago) and global tectonics (approximately 3 billion years ago) suggests that plates and plate boundaries became widespread over a period of 1 billion years. The reason for this time lag is unknown but fundamental to understanding the origin of plate tectonics. Here we suggest that when sufficient lithospheric damage (which promotes shear localization and long-lived weak zones) combines with transient mantle flow and migrating proto-subduction, it leads to the accumulation of weak plate boundaries and eventually to fully formed tectonic plates driven by subduction alone. We simulate this process using a grain evolution and damage mechanism with a composite rheology (which is compatible with field and laboratory observations of polycrystalline rocks), coupled to an idealized model of pressure-driven lithospheric flow in which a low-pressure zone is equivalent to the suction of convective downwellings. In the simplest case, for Earth-like conditions, a few successive rotations of the driving pressure field yield relic damaged weak zones that are inherited by the lithospheric flow to form a nearly perfect plate, with passive spreading and strike-slip margins that persist and localize further, even though flow is driven only by subduction. But for hotter surface conditions, such as those on Venus, accumulation and inheritance of damage is negligible; hence only subduction zones survive and plate tectonics does not spread, which corresponds to observations. After plates have developed, continued changes in driving forces, combined with inherited damage and weak zones, promote increased tectonic complexity, such as oblique subduction, strike-slip boundaries that are subparallel to plate motion, and spalling of minor plates.

  9. Casimir Effect for Dielectric Plates

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    We generalize Kupisewska method to the three-dimensional system and another derivation of the Casimir effect between two dielectric plates is presented based on the explicit quantization of the electromagnetic field in the presence of dielectrics, where the physical meaning of "evanescent mode" is discussed. The Lifshitz's formula is rederived perfect metallic plates will the evanescent modes become unimportant.

  10. Micro-channel plate detector

    Science.gov (United States)

    Elam, Jeffrey W.; Lee, Seon W.; Wang, Hsien -Hau; Pellin, Michael J.; Byrum, Karen; Frisch, Henry J.

    2015-09-22

    A method and system for providing a micro-channel plate detector. An anodized aluminum oxide membrane is provided and includes a plurality of nanopores which have an Al coating and a thin layer of an emissive oxide material responsive to incident radiation, thereby providing a plurality of radiation sensitive channels for the micro-channel plate detector.

  11. Gold plating on spectacle frames.

    Science.gov (United States)

    Kenny, I; Mitchell, J W; Walsh, G

    1997-05-01

    An investigation was carried out into the thickness and standard of application of the plating and lacquer coatings applied to three metal spectacle frames. All conform to BS 6625 (1991) for plating thickness, but there was considerable variation in regularity and porosity.

  12. Production of quartz plates for CMS-CASTOR Experiment

    CERN Document Server

    Adiguzel, Aytul; Ayhan, Aydin; Bakirci, Mustafa Numan; Basegmez, Suzan; Beaumont, Willem; Borras, Kerstin; Campbell, Alan; De Paula Carvalho, W; Çerçi, Salim; De Jesus Damiao, Dilson; Dogangün, O; Dumanoglu, Isa; d'Enterria, David; Erchov, Y; Eskut, Eda; Figueiredo, D; Girgis, Semiray; Göttlicher, P; Gouskos, Loukas; Gurpinar, Emine; Hos, Ilknur; Katkov, Igor; Katsas, Panagiotis; Khein, Lev; Knutsson, Albert; Kuznetsov, Andrey; Lebeau, Michel; Van Mechelen, Pierre; Muhl, Carsten; Musienko, Yuri; Ochesanu, Silvia; Onengüt, G; Onengut, G Jr; Ozdemir, Kadri; Panagiotou, Apostolos; Polatoz, A; Ripert, Marion; Shileev, K; Sogut, Kenan; Tiflov, B TaliV; Kayis-Topaksu, A; Uzun, Dilber

    2008-01-01

    Light transmission rate performance of $102$ irradiated quartz samples was measured to select the best quartz plates for CMS-CASTOR calorimeter. All the produced quartz plates were originally used in a previous CERN experiment, DELPHI. Three different doses of $^{60}$Co source were used with the collaboration of PSI (Paul Scherrer Institute, Villigen PSI, Switzerland.) to study the transmission rate performance of the quartz samples after irradiation for different incident light, ranging from $250$ to $700$ nm in $5$ nm increasing steps. All samples show different decrease in the rate with wavelength for different doses. Three different steps were followed before irradiation to find out the best way of cleaning the original DELPHI Cu/Cr tracks on the samples. Results of these measurements presented here correspond to the quartz plates that will be used in one hadronic sector of CASTOR calorimeter until end of 2008. For the full calorimeter new quartz plates will be installed. We also present the light transmi...

  13. The moving plate capacitor paradox

    Science.gov (United States)

    Davis, B. R.; Abbott, D.; Parrondo, J. M. R.

    2000-03-01

    For the first time we describe an apparent paradox concerning a moving plate capacitor driven by thermal noise from a resistor. A demon restores the plates of the capacitor to their original position, only when the voltage across the capacitor is small—hence only small forces are present for the demon to work against. The demon has to work harder than this to avoid the situation of perpetual motion, but the question is how? We explore the concept of a moving plate capacitor, driven by noise, a step further by examining the case where the restoring force on the capacitor plates is provided by a simple spring, rather than some unknown demon. We display simulation results with interesting behavior, particularly where the capacitor plates collide with each other.

  14. SAMI Automated Plug Plate Configuration

    CERN Document Server

    Lorente, Nuria P F; Goodwin, Michael

    2012-01-01

    The Sydney-AAO Multi-object Integral field spectrograph (SAMI) is a prototype wide-field system at the Anglo-Australian Telescope (AAT) which uses a plug-plate to mount its 13 x 61-core imaging fibre bundles (hexabundles) in the optical path at the telescope's prime focus. In this paper we describe the process of determining the positions of the plug-plate holes, where plates contain three or more stacked observation configurations. The process, which up until now has involved several separate processes and has required significant manual configuration and checking, is now being automated to increase efficiency and reduce error. This is carried out by means of a thin Java controller layer which drives the configuration cycle. This layer controls the user interface and the C++ algorithm layer where the plate configuration and optimisation is carried out. Additionally, through the Aladin display package, it provides visualisation and facilitates user verification of the resulting plates.

  15. Plate Motions Predicted from Global Dynamic Models and Seismic Tomography: The Problem of North American Plate Motion

    Science.gov (United States)

    Liu, S.; King, S. D.; Adam, C. M.

    2016-12-01

    Seismic tomography is a snapshot of the mantle convection system and provides important constraints on Earth's internal dynamics. An increasing number of global seismic tomography models along with various rheological structures have been used to compute mantle flow pattern and the resulting surface expressions, including dynamic topography and geoid. Accurately predicting the plate motion from the mantle dynamic models is a challenge particularly with the newest generation of seismic tomography models (e.g., S40RTS, SAVANI), especially for the North American plate which only has a little subduction along it's boundary. The difficulties include the uncertainty of the velocity-to-density scaling, discrepancies between different seismic tomography models, and the computational technology to solve for global mantle flow with observationally constrained high resolution models. We use the code ASPECT (Advanced Solver for Problems in Earth CovecTion) to make a series of tests to derive mantle flow pattern from different global seismic tomography models and rheological structures. We further make a quantitative statistical comparison between the modeled and observed plate motions in terms of flow magnitude, flow direction, and plateness within each plate area. We investigate how the velocity-to-density scaling, the features of seismic tomography models, and the lateral rheological structures of the lithosphere and upper mantle influence the modeled plate motions. We find that the velocity-to-density scaling mainly changes the flow magnitude and has little impact on the flow direction. The results of different seismic tomography models are similar broadly but can be quite different in some regions. The presence of lateral viscosity variations including stiff cratons, weak plate boundary zones, and high viscosity slabs along with density variations from seafloor age and subducting slabs can improve the fit to observed plate motions. With a very small fraction of subduction

  16. Thin plate neotectonic models of the Australian plate

    Science.gov (United States)

    Burbidge, D. R.

    2004-10-01

    Thin plate finite element models of the neotectonic deformation of the Australian plate have been calculated in order to estimate the stress and strain rate within the plate, specifically concentrating on the Australian continent. The model includes plate-bounding faults, an anelastic brittle-ductile layered rheology and the option of laterally varying elevation and heat flow. The results of the models are compared to (1) the velocity of geodetic benchmarks on the Australian plate, (2) the spreading rate of the mid-oceanic ridges along the Australian plate's margins, (3) the direction of the maximum horizontal principal stress, (4) the stress regime within the plate, and (5) the crustal thickness estimated from the depth to the base of Mohorovicic discontinuity's transition zone. A variety of models are tested with a wide range of input parameters. The model with the smallest misfit with observations predicts that the strain rate for most of the Australian continent is approximately 10-17 s-1. This model has a slightly lower strain rate in the central Australia and is higher off the northern coast of Australia than for the rest of the continent. Strain rates of this magnitude would be difficult to observe from geodetic or geologic data for most parts of Australia but would be enough to generate much of the seismicity that has been observed over the last century.

  17. Underwater electrical discharge in plate to plate configuration

    Science.gov (United States)

    Stelmashuk, Vitaliy

    2016-09-01

    Two main configurations of high voltage electrodes submersed in water have been used for an electrical discharge generation: pin to pin and pin to plate. An electrical breakdown between plate electrodes is generally difficult to reproduce, because there is a uniform and weak electric field. One major advantage of using plate electrodes is their greater ``wear hardness'' to high-energy discharges. The plate electrodes can withstand extremely high energy deposition at which the pin electrode is quickly destroyed. The electrical discharge between plate electrodes can be initiated by creating an inhomogeneity in the electrical field. Two methods of discharge initiation between plate electrodes are proposed for this aim: 1) focusing of a shock wave in the interelectrode region; 2) a bubble injection into the electrode gap. The shock wave creates favourable conditions for the electrical breakdown between the two plate electrodes: it causes that numerous microbubbles of dissolved air start to grow and serve as locations for streamer initiation. In the second method the gas bubble is injected from the one of the electrodes, which has a gas inlet hole on the lateral face for this purpose. A ``volcano'' like morphology of positive streamers are observed in the experiments with weak electric field. The authors are grateful to MEYS grant INGO LG 15013.

  18. Plate size does not affect perception of food portion size.

    Science.gov (United States)

    Penaforte, F R O; Japur, C C; Diez-Garcia, R W; Hernandez, J C; Palmma-Linares, I; Chiarello, P G

    2014-04-01

    Evidences have suggested that larger utensils may provoke 'size-contrast illusions', influencing the perceived volume and food consumption. To analyse the influence of plate size on the visual estimate of food portion size. Two 400 g portions of pasta with tomato sauce were presented on two plates of different diameters (24.0 and 9.0 cm). Each participant visually estimated on an individual basis the quantities of the pasta portions (g) present on each plate. In addition, each subject classified the size of the portions on each plate as 'small', 'medium' and 'large'. The mean estimates of the amount of pasta on each plate were compared by the nonparametric Mann-Whitney. The differences in the frequencies of portion classifications between plates were evaluated by the chi-squared test. Forty-eight students (average 25.8 ± 8.9 years) participated in the study. There was no difference in the median amount of pasta estimated for the large and small plates (150 g; range 50-500 and 115 g; range 40-500 g, respectively). The classification of the portion size as 'large' was reported by a significantly greater number of persons when they evaluated the amount of pasta arranged on the large plate compared to the small plate (47.9 versus 22.9%, respectively; P = 0.018). The size of the plate did not influence the estimate of food portions, even though it did influence the classification of portion size. © 2013 The Authors Journal of Human Nutrition and Dietetics © 2013 The British Dietetic Association Ltd.

  19. Finite element analysis of different tibial shaft fracture fixed by Locking compression plate under different movement gait%不同运动步态下锁定加压钢板固定胫骨干骨折的有限元分析*★

    Institute of Scientific and Technical Information of China (English)

    李赟罡; 陈为坚; 李贵涛; 孙鸿涛; 颜建豪; 王雄昌; 王晶

    2013-01-01

      背景:目前有限元分析广泛应用于人体骨折内固定模型的力学分析,但大多研究局限于静态下,动态下的骨折模型有限元分析尚未见报道。目的:通过三维有限元分析来探讨锁定加压钢板固定胫骨干不同类型骨折在不同运动步态下的应力分布情况。方法:利用 CT 扫描获得正常成人胫腓骨及足部的薄层扫描图像;运用相关软件建立其三维模型,在此模型上模拟出胫骨中段横行、斜行、粉碎性、螺旋形4种类型骨折,并与锁定钢板进行装配生成实验模型,各组模型加载相同的轴向压缩载荷600 N。通过有限元分析软件 Ansys 12.0分别测定各组模型在落地相、中立相、离地相三种步态下的应力分布情况。结果与结论:在步态下,胫骨在骨折各组中的应力分布由小到大均为:落地相<中立相<离地相。锁定钢板在胫骨中段横行、斜行、粉碎性骨折中的应力分布由小到大均为:中立相<落地相<离地相;在胫骨中段螺旋形骨折中应力分布由小到大为:离地相<中立相<落地相;提示在运动步态中,钢板和胫骨均在离地相受力最大。钢板的应力集中在中间或边缘;而胫骨的应力分布在骨折线以上靠近近端,骨折线以下靠近骨折线。就胫骨整体而言,呈现两端集中,中间分散的状态。%BACKGROUND: In recent years, the finite element analysis has been widely used in the mechanical analysis of human fracture internal fixation model, but studies on the finite element analysis are often under the static state, the reports on the finite element analysis under physiological state are few. OBJECTIVE: To explore the stress distribution of different tibial shaft fractures fixed by locking compression plate under different movement gaits through three-dimensional finite element analysis. METHODS: CT scan was performed to obtain the thin layer scanning image of

  20. Plate tectonic raster reconstruction in GPlates

    Directory of Open Access Journals (Sweden)

    J. Cannon

    2014-03-01

    Full Text Available We describe a novel method implemented in the GPlates plate tectonic reconstruction software to interactively reconstruct arbitrarily high-resolution raster data to past geological times using a rotation model. The approach is based on the projection of geo-referenced raster data into a cube map followed by a reverse projection onto rotated tectonic plates on the surface of the globe. This decouples the rendering of a geo-referenced raster from its reconstruction, providing a number of benefits including a simple implementation and the ability to combine rasters with different geo-referencing or inbuilt raster projections. The cube map projection is accelerated by graphics hardware in a wide variety of computer systems manufactured over the last decade. Furthermore, by integrating a multi-resolution tile partitioning into the cube map we can provide on-demand tile streaming, level-of-detail rendering and hierarchical visibility culling enabling researchers to visually explore essentially unlimited resolution geophysical raster data attached to tectonic plates and reconstructed through geological time. This capability forms the basis for interactively building and improving plate reconstructions in an iterative fashion, particularly for tectonically complex regions.

  1. Transversal vibrations of double-plate systems

    Institute of Scientific and Technical Information of China (English)

    Katica(Stevanovi(c)) Hedrih

    2006-01-01

    This paper presents an analytical and numerical analysis of free and forced transversal vibrations of an elastically connected double-plate system. Analytical solutions of a system of coupled partial differential equations, which describe corresponding dynamical free and forced processes, are obtained using Bernoulli's particular integral and Lagrange's method of variation constants. It is shown that one-mode vibrations correspond to two-frequency regime for free vibrations induced by initial conditions and to three-frequency regime for forced vibrations induced by one-frequency external excitation and corresponding initial conditions. The analytical solutions show that the elastic connection between plates leads to the appearance of twofrequency regime of time function, which corresponds to one eigenamplitude function of one mode, and also that the time functions of different vibration modes are uncoupled, for each shape of vibrations. It has been proven that for both elastically connected plates, for every pair of m and n. two possibilities for appearance of the resonance dynamical states, as well as for appearance of the dynamical absorption, are present. Using the MathCad program, the corresponding visualizations of the characteristic forms of the plate middle surfaces through time are presented.

  2. Development of microtitre plates for electrokinetic assays

    Science.gov (United States)

    Burt, J. P. H.; Goater, A. D.; Menachery, A.; Pethig, R.; Rizvi, N. H.

    2007-02-01

    Electrokinetic processes have wide ranging applications in microsystems technology. Their optimum performance at micro and nano dimensions allows their use both as characterization and diagnostic tools and as a means of general particle manipulation. Within analytical studies, measurement of the electrokinesis of biological cells has the sensitivity and selectivity to distinguish subtle differences between cell types and cells undergoing changes and is gaining acceptance as a diagnostic tool in high throughput screening for drug discovery applications. In this work the development and manufacture of an electrokinetic-based microtitre plate is described. The plate is intended to be compatible with automated sample loading and handling systems. Manufacturing of the microtitre plate, which employs indium tin oxide microelectrodes, has been entirely undertaken using excimer and ultra-fast pulsed laser micromachining due to its flexibility in materials processing and accuracy in microstructuring. Laser micromachining has the ability to rapidly realize iterations in device prototype design while also having the capability to be scaled up for large scale manufacture. Device verification is achieved by the measurement of the electrorotation and dielectrophoretic properties of yeast cells while the flexibility of the developed microtitre plate is demonstrated by the selective separation of live yeast from polystyrene microbeads.

  3. Highly curved microchannel plates

    Science.gov (United States)

    Siegmund, O. H. W.; Cully, S.; Warren, J.; Gaines, G. A.; Priedhorsky, W.; Bloch, J.

    1990-01-01

    Several spherically curved microchannel plate (MCP) stack configurations were studied as part of an ongoing astrophysical detector development program, and as part of the development of the ALEXIS satellite payload. MCP pairs with surface radii of curvature as small as 7 cm, and diameters up to 46 mm have been evaluated. The experiments show that the gain (greater than 1.5 x 10 exp 7) and background characteristics (about 0.5 events/sq cm per sec) of highly curved MCP stacks are in general equivalent to the performance achieved with flat MCP stacks of similar configuration. However, gain variations across the curved MCP's due to variations in the channel length to diameter ratio are observed. The overall pulse height distribution of a highly curved surface MCP stack (greater than 50 percent FWHM) is thus broader than its flat counterpart (less than 30 percent). Preconditioning of curved MCP stacks gives comparable results to flat MCP stacks, but it also decreases the overall gain variations. Flat fields of curved MCP stacks have the same general characteristics as flat MCP stacks.

  4. Indonesian Landforms and Plate Tectonics

    Directory of Open Access Journals (Sweden)

    Herman Th. Verstappen

    2014-06-01

    Full Text Available DOI: 10.17014/ijog.v5i3.103The horizontal configuration and vertical dimension of the landforms occurring in the tectonically unstable parts of Indonesia were resulted in the first place from plate tectonics. Most of them date from the Quaternary and endogenous forces are ongoing. Three major plates – the northward moving Indo-Australian Plate, the south-eastward moving SE-Asian Plate and the westward moving Pacific Plate - meet at a plate triple-junction situated in the south of New Guinea’s Bird’s Head. The narrow North-Moluccan plate is interposed between the Asia and Pacific. It tapers out northward in the Philippine Mobile Belt and is gradually disappearing. The greatest relief amplitudes occur near the plate boundaries: deep ocean trenches are associated with subduction zones and mountain ranges with collision belts. The landforms of the more stable areas of the plates date back to a more remote past and, where emerged, have a more subdued relief that is in the first place related to the resistance of the rocks to humid tropical weathering Rising mountain ranges and emerging island arcs are subjected to rapid humid-tropical river erosions and mass movements. The erosion products accumulate in adjacent sedimentary basins where their increasing weight causes subsidence by gravity and isostatic compensations. Living and raised coral reefs, volcanoes, and fault scarps are important geomorphic indicators of active plate tectonics. Compartmental faults may strongly affect island arcs stretching perpendicular to the plate movement. This is the case on Java. Transcurrent faults and related pull-apart basins are a leading factor where plates meet at an angle, such as on Sumatra. The most complicated situation exists near the triple-junction and in the Moluccas. Modern research methods, such as GPS measurements of plate movements and absolute dating of volcanic outbursts and raised coral reefs are important tools. The mega-landforms resulting

  5. Indonesian Landforms and Plate Tectonics

    Directory of Open Access Journals (Sweden)

    Herman Th. Verstappen

    2014-06-01

    Full Text Available DOI: 10.17014/ijog.v5i3.103The horizontal configuration and vertical dimension of the landforms occurring in the tectonically unstable parts of Indonesia were resulted in the first place from plate tectonics. Most of them date from the Quaternary and endogenous forces are ongoing. Three major plates – the northward moving Indo-Australian Plate, the south-eastward moving SE-Asian Plate and the westward moving Pacific Plate - meet at a plate triple-junction situated in the south of New Guinea’s Bird’s Head. The narrow North-Moluccan plate is interposed between the Asia and Pacific. It tapers out northward in the Philippine Mobile Belt and is gradually disappearing. The greatest relief amplitudes occur near the plate boundaries: deep ocean trenches are associated with subduction zones and mountain ranges with collision belts. The landforms of the more stable areas of the plates date back to a more remote past and, where emerged, have a more subdued relief that is in the first place related to the resistance of the rocks to humid tropical weathering Rising mountain ranges and emerging island arcs are subjected to rapid humid-tropical river erosions and mass movements. The erosion products accumulate in adjacent sedimentary basins where their increasing weight causes subsidence by gravity and isostatic compensations. Living and raised coral reefs, volcanoes, and fault scarps are important geomorphic indicators of active plate tectonics. Compartmental faults may strongly affect island arcs stretching perpendicular to the plate movement. This is the case on Java. Transcurrent faults and related pull-apart basins are a leading factor where plates meet at an angle, such as on Sumatra. The most complicated situation exists near the triple-junction and in the Moluccas. Modern research methods, such as GPS measurements of plate movements and absolute dating of volcanic outbursts and raised coral reefs are important tools. The mega-landforms resulting

  6. Imaging with straight-edge phase plates in the TEM.

    Science.gov (United States)

    Edgcombe, C J

    2017-06-22

    The image of a simple phase object produced by a round lens with a Foucault or Hilbert phase plate can be determined with Abbe imaging theory and a 2D transform expressed in cylindrical coordinates. The contributions to the image amplitude from a uniform disc object and an azimuthally varying plate can then be distinguished and their phases relative to the incident wave can be compared. It appears that the usual choice of added phase for a Hilbert plate causes the image of a weak disc object to vanish as the plate edge approaches the axis, but a different choice of plate thickness can enable a weak phase object to provide a linear contribution to image intensity. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Closed form solutions for free vibrations of rectangular Mindlin plates

    Institute of Scientific and Technical Information of China (English)

    Yufeng Xing; Bo Liu

    2009-01-01

    A new two-eigenfunctions theory, using the amplitude deflection and the generalized curvature as two fundamental eigenfunctions, is proposed for the free vibration solutions of a rectangular Mindlin plate. The three classical eigenvalue differential equations of a Mindlin plate are reformulated to arrive at two new eigenvalue differential equations for the proposed theory. The closed form eigensolutions, which are solved from the two differential equations by means of the method of separation of variables are identical with those via Kirchhoff plate theory for thin plate, and can be employed to predict frequencies for any combinations of simply supported and clamped edge conditions. The free edges can also be dealt with if the other pair of opposite edges are simply supported. Some of the solutions were not available before. The frequency parameters agree closely with the available ones through pb-2 Rayleigh-Ritz method for different aspect ratios and relative thickness of plate.

  8. Prediction of the point of impact in an anisotropic plate

    Science.gov (United States)

    Koabaz, M.; Hajzargarbashi, T.; Kundu, T.; Deschamps, M.

    2011-01-01

    Locating the point of impact of a foreign object in a plate is important for continuous health monitoring of structures. A new method based on an optimization scheme has been recently proposed to locate the point of impact in anisotropic plates by analyzing the times of arrival of the ultrasonic signals at the passive sensors attached to the plate. Following this optimization based technique, in this paper the impact point on an anisotropic plate is predicted from the acoustic emission data. Experiments are carried out with a carbon-epoxy plate where the impact point is modeled by an acoustic source. A Parallel Pre-stressed Actuator (PPA) is used as the acoustic source and the acoustic signals at different locations are received by adhesively bonded acoustic sensors. The source point is then predicted and compared with its actual location. Related theory is also presented in the paper.

  9. Improved modelling of a parallel plate active magnetic regenerator

    DEFF Research Database (Denmark)

    Engelbrecht, Kurt; Tušek, J.; Nielsen, Kaspar Kirstein;

    2013-01-01

    flow maldistribution in the regenerator. This paper studies the effects of these loss mechanisms and compares theoretical results with experimental results obtained on an experimental AMR device. Three parallel plate regenerators were tested, each having different demagnetizing field characteristics...

  10. The moment problem and vibrations damping of beams and plates

    Energy Technology Data Exchange (ETDEWEB)

    Atamuratov, Andrey G. [Pepsico Holding LTD, Leningrad Avenue, 72/4, 125315 Moscow (Russian Federation); Mikhailov, Igor E. [Dorodnicyn Computing Centre of RAS, Vavilov str., 40, 119333 Moscow (Russian Federation); Muravey, Leonid A. [Russian State Technological University, Orshanskaya str., 3, 121552 Moscow (Russian Federation)

    2016-06-08

    Beams and plates are the elements of different complex mechanical structures, for example, pipelines and aerospace platforms. That is why the problem of damping of their vibrations caused by unwanted perturbations is actual task.

  11. Development of a simulation plate-form for ACC radar application

    OpenAIRE

    GALLEE, F; APPERE, C; Leroux, D; Peden, A; Ney, M.; Gruyer, D.

    2011-01-01

    This paper presents a simulation plate-form of an Adaptative Cruise Control radar. This simulation plate-form will be implemented in a multi-sensor simulator for ADAS system design. In this paper, the principle of the simulation plate-form is explained and illustrated with different examples.

  12. Plate reactor as an analysis tool for rapid pyrolysis of biomass

    NARCIS (Netherlands)

    Sepman, A. V.; de Goey, L. P. H.

    2011-01-01

    This work presents a study of the performance of the modified plate reactor by rapid pyrolysis experiments with different biomass samples (MDF, bark pine and Avicel cellulose). The use of the plate instead of a grid allowed us to achieve a more homogeneous temperature distribution across the plate a

  13. Interaction between plate make and protein in protein crystallisation screening.

    Directory of Open Access Journals (Sweden)

    Gordon J King

    Full Text Available BACKGROUND: Protein crystallisation screening involves the parallel testing of large numbers of candidate conditions with the aim of identifying conditions suitable as a starting point for the production of diffraction quality crystals. Generally, condition screening is performed in 96-well plates. While previous studies have examined the effects of protein construct, protein purity, or crystallisation condition ingredients on protein crystallisation, few have examined the effect of the crystallisation plate. METHODOLOGY/PRINCIPAL FINDINGS: We performed a statistically rigorous examination of protein crystallisation, and evaluated interactions between crystallisation success and plate row/column, different plates of same make, different plate makes and different proteins. From our analysis of protein crystallisation, we found a significant interaction between plate make and the specific protein being crystallised. CONCLUSIONS/SIGNIFICANCE: Protein crystal structure determination is the principal method for determining protein structure but is limited by the need to produce crystals of the protein under study. Many important proteins are difficult to crystallize, so that identification of factors that assist crystallisation could open up the structure determination of these more challenging targets. Our findings suggest that protein crystallisation success may be improved by matching a protein with its optimal plate make.

  14. History and Evolution of Precambrian plate tectonics

    Science.gov (United States)

    Fischer, Ria; Gerya, Taras

    2014-05-01

    Plate tectonics is a global self-organising process driven by negative buoyancy at thermal boundary layers. Phanerozoic plate tectonics with its typical subduction and orogeny is relatively well understood and can be traced back in the geological records of the continents. Interpretations of geological, petrological and geochemical observations from Proterozoic and Archean orogenic belts however (e.g., Brown, 2006), suggest a different tectonic regime in the Precambrian. Due to higher radioactive heat production the Precambrian lithosphere shows lower internal strength and is strongly weakened by percolating melts. The fundamental difference between Precambrian and Phanerozoic tectonics is therefore the upper-mantle temperature, which determines the strength of the upper mantle (Brun, 2002) and the further tectonic history. 3D petrological-thermomechanical numerical modelling experiments of oceanic subduction at an active plate at different upper-mantle temperatures show these different subduction regimes. For upper-mantle temperatures buckling and also lithospheric delamination and drip-offs. For upper-mantle temperatures > 250 K above the present day value no subduction occurs any more. The whole lithosphere is delaminating and due to strong volcanism and formation of a thicker crust subduction is inhibited. This stage of 200-250 K higher upper mantle temperature which corresponds roughly to the early Archean (Abbott, 1994) is marked by strong volcanism due to sublithospheric decompression melting which leads to an equal thickness for both oceanic and continental plates. As a consequence subduction is inhibited, but a compressional setup instead will lead to orogeny between a continental or felsic terrain and an oceanic or mafic terrain as well as internal crustal convection. Small-scale convection with plume shaped cold downwellings also in the upper mantle is of increased importance compared to the large-scale subduction cycle observed for present temperature

  15. Liquid crystal thermography. A method for monitoring temperature gradients in microtitration plates.

    Science.gov (United States)

    Oliver, D G; Sanders, A H; Jang, L; Poy, D; Van Heuvelen, A

    1983-03-11

    Precise quantitative heat transfer information in microtitration plates can be obtained by filling the wells of a microtitration plate with cholesteric liquid crystals and incubating the plates at the desired temperature in different incubators. The liquid crystals indicate temperature by changes in discrete reproducible colors over various temperature ranges. With these instrumented plates, interwell thermal gradients may be documented visually and are in close agreement with results obtained by using wire thermocouple measuring techniques.

  16. A water-like model under confinement for hydrophobic and hydrophilic particle-plate interaction potentials

    OpenAIRE

    Krott, Leandro B.; BARBOSA, Marcia C.

    2013-01-01

    Molecular dynamic simulations were employed to study a water-like model confined between hydrophobic and hydrophilic plates. The phase behavior of this system is obtained for different distances between the plates and particle-plate potentials. For both hydrophobic and hydrophilic walls there are the formation of layers. Crystallization occurs at lower temperature at the contact layer than at the middle layer. In addition, the melting temperature decreases as the plates become more hydrophobi...

  17. Point of Impact Prediction in Anisotropic Fiber Reinforced Composite Plates from the Acoustic Emission Data

    Science.gov (United States)

    Kundu, T.; Das, S.; Jata, K. V.

    2008-02-01

    A newly developed optimization based method is followed to locate the point of impact in anisotropic composite plates for which conventional triangulation technique fails. The new technique works for both anisotropic and isotropic plates. Experiments are carried out by dropping a steel ball on a graphite-epoxy composite plate and picking up acoustic signals by passive transducers adhesively bonded to the plate at different locations. Predicted points of impact are compared with the true impact point.

  18. Optical Near-Field Plates

    Science.gov (United States)

    2015-04-08

    color filtering and spectral imaging ,” Nat. Comm. 1, 59 (2010). 3. H.-F. Shi and L. J. Guo, “Design of Plasmonic Near Field Plate at Opitical...AFRL-OSR-VA-TR-2015-0085 OPTICAL NEAR-FILED PLATES Roberto Merlin UNIVERSITY OF MICHIGAN Final Report 04/08/2015 DISTRIBUTION A: Distribution...03-2015 Final 09/01/2009-12/31/2014 Optical Near-Field Plates FA9550-09-1-0636 erlin, Roberto, D. The University of Michigan Ann Arbor, MI 48109

  19. Plate shell structures of glass

    DEFF Research Database (Denmark)

    Bagger, Anne

    to their curved shape. A plate shell structure maintains a high stiffness-to-weight ratio, while facilitating the use of plane structural elements. The study focuses on using laminated glass panes for the load bearing facets. Various methods of generating a plate shell geometry are suggested. Together with Ghent......, such as facet size, imperfections, and connection characteristics. The critical load is compared to that of a similar, but smoothly curved, shell structure. Based on the investigations throughout the study, a set of guidelines for the structural design of plate shells of glass is proposed....

  20. A lumped mass finite element method for vibration analysis of elastic plate-plate structures

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    The fully discrete lumped mass finite element method is proposed for vibration analysis of elastic plate-plate structures.In the space directions,the longitudinal displacements on plates are discretized by conforming linear elements,and the transverse displacements are discretized by the Morley element.By means of the second order central difference for discretizing the time derivative and the technique of lumped masses,a fully discrete lumped mass finite element method is obtained,and two approaches to choosing the initial functions are also introduced.The error analysis for the method in the energy norm is established,and some numerical examples are included to validate the theoretical analysis.

  1. Fractal zone plate beam based optical tweezers

    Science.gov (United States)

    Cheng, Shubo; Zhang, Xinyu; Ma, Wenzhuo; Tao, Shaohua

    2016-01-01

    We demonstrate optical manipulation with an optical beam generated by a fractral zone plate (FZP). The experimental results show that the FZP beam can simultaneously trap multiple particles positioned in different focal planes of the FZP beam, owing to the multiple foci and self-reconstruction property of the FZP beam. The FZP beam can also be used to construct three-dimensional optical tweezers for potential applications. PMID:27678305

  2. Modeling of Bullet Penetration in Explosively Welded Composite Armor Plate

    Science.gov (United States)

    Joshi, Vasant S.; Carney, Theodore C.

    2006-07-01

    Normal impact of high-speed armor piercing bullet on titanium-steel composite has been investigated using smooth particle hydrodynamics (SPH) code. The objective is to understand the effects of impact during the ballistic testing of explosively welded armor plates. These plates have significant microstructural differences within the weld region, heat-affected zone and the base metal. The variances result in substantial ductility, hardness and strength differences, important criteria in determining the failure mode, specifically whether it occurs at the joint or within the virgin base metal. Several configurations of composite plates with different material combinations were modeled. The results were used to modify the heat treatment process of explosively welded plates, making them more likely to survive impact.

  3. 不同黄板处理对美洲斑潜蝇诱杀效果比较%The Comparison of the Booby Traps Effect on L iriomyza Sativae in Different Yellow Plate

    Institute of Scientific and Technical Information of China (English)

    江春; 程建伟; 许飞云

    2013-01-01

      利用美洲斑潜蝇对黄色具有明显的趋性制作黄板进行防治,结果显示:美洲斑潜蝇对柠檬黄色趋性最强,黄板以东西方向悬挂为宜,尽量悬挂于温室大棚北侧和中部,悬挂高度以黄板下缘高于蔬菜5 cm为佳,黄板表面涂厚度为0.1 cm的2份机油与1份凡士林混合油.尤其在虫害刚发生时进行防治效果更好.%  The prevention against Liriomyza sativae by the production of yellow plates that Liriomyza sativae tend to approach shows that it was effective for the traps of Liriomyza sativae in the lemon yellow plate, which was hung up in an east-west direction, the middle and the north side of the greenhouse in the height of 5cm over vegetables, and which was covered with a thickness of 2 parts of 0.1cm oil and 1 part of Vaseline mixed oil. It is better to prevent especially when the pests appear.

  4. The multigap resistive plate chamber

    Energy Technology Data Exchange (ETDEWEB)

    Zeballos, E. Cerron [European Organization for Nuclear Research (CERN), Geneva (Switzerland); World Lab., Lausanne (Switzerland); Crotty, I. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Hatzifotiadou, D. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); World Lab., Lausanne (Switzerland); Valverde, J. Lamas [European Organization for Nuclear Research (CERN), Geneva (Switzerland); World Lab., Lausanne (Switzerland); Univ. Louis Pasteur, Strasbourg (France); Neupane, S. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); World Lab., Lausanne (Switzerland); Williams, M. C. S. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Zichichi, A. [Univ. of Bologna, Bologna (Italy)

    2015-02-03

    The paper describes the multigap resistive plate chamber (RPC). This is a variant of the wide gap RPC. However it has much improved time resolution, while keeping all the other advantages of the wide gap RPC design.

  5. An efficient rectangular plate element

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A new 12-parameter rectangular plate element is presented by useof the double set parameter method. The error in the energy norm is of order O(h2), one order higher than the commonly used Adini nonconforming element.

  6. Tectonics: Changing of the plates

    Science.gov (United States)

    Brandon, Alan

    2016-10-01

    The composition of Earth's crust depends on the style of plate tectonics and of the melting regimes in the mantle. Analyses of the oldest identified rocks suggest that these styles and the resulting crust have changed over Earth's history.

  7. A method for designing plates in treatments of proximal humeral fracture and distal radial fracture

    Directory of Open Access Journals (Sweden)

    Lin Wang

    2016-11-01

    Full Text Available The purpose of this paper was to quickly design fixation plates for fractured proximal humerus and distal radius according to the requirements of surgical treatment. Therefore, a new method to quickly design cloverleaf plate appropriate for proximal humerus and volar plate appropriate for distal radius is put forward. First, three-dimensional (3D reconstruction models of fractured proximal humerus and distal radius were generated based on deforming mean parametric models of proximal humerus and distal radius, respectively. Second, based on region-of-interest marked on the 3D reconstruction model of proximal humerus and distal radius, abutted surfaces of cloverleaf plate and volar plate were established, respectively. Then, parametric abutted surface was established after setting rational parameters for the surface of the cloverleaf plate. Parametric abutted surface of volar plate was established using the same method. Finally, parametric cloverleaf plate and volar plate are generated through thickening their respective parametric abutted surfaces. The parametric plates, acting as templates, accelerate and simplify the design process and therefore allow users to construct plate with editing valid parameters easily. Group of cloverleaf plates and volar plates with different sizes were generated quickly, showing that the proposed method is feasible and effective.

  8. Models of convection-driven tectonic plates - A comparison of methods and results

    Science.gov (United States)

    King, Scott D.; Gable, Carl W.; Weinstein, Stuart A.

    1992-01-01

    Recent numerical studies of convection in the earth's mantle have included various features of plate tectonics. This paper describes three methods of modeling plates: through material properties, through force balance, and through a thin power-law sheet approximation. The results obtained are compared using each method on a series of simple calculations. From these results, scaling relations between the different parameterizations are developed. While each method produces different degrees of deformation within the surface plate, the surface heat flux and average plate velocity agree to within a few percent. The main results are not dependent upon the plate modeling method and herefore are representative of the physical system modeled.

  9. Comparision of Two Thermal Decomposition Offset Printing Plates

    Directory of Open Access Journals (Sweden)

    Ana Jereb

    2015-03-01

    Full Text Available The aim of our research was to investigate two digital plates based on the same type of thermal sensitive coating produced by different manufactures and compare their quality, run length, ecological and economical aspects and user experience in the offset press. It was found out that with both plates the same quality of prints was attained according to the measurements of tone values on the plates and prints. The spectrophotometric measurements also showed that the prints were almost identical, except for minor differences in lightness. The microscopic image analysis showed that one plate had finer graining and thereby gave better and more accurate representation of half-tone dot and this plate was also more environmentally–friendly with lower consumption of chemicals for the plate developing, more durable with longer run lengths and as well more economical and user–friendly. The obtained results were useful for the offset printing company in its choosing the better thermal plate with reduced production costs.

  10. 2-Mercaptobenzimidazole, 2-Mercaptobenzothiazole, and Thioglycolic Acid in an Electroless Nickel-Plating Bath

    Directory of Open Access Journals (Sweden)

    Ahmet Ozan Gezerman

    2015-01-01

    Full Text Available The use of three different materials, 2-mercaptobenzimidazole, 2-mercaptobenzothiazole, and thioglycolic acid, was investigated to improve the performance of electroless nickel-plating baths. By changing the concentrations of these materials, sample plates were coated. Optical microscope images were obtained by selecting representative coated plates. From the results of the investigations, the effects of these materials on electroless nickel plating were observed, and the most appropriate amounts of these materials for nickel plating were determined. Moreover, the nickel plating speed observed with the bath solution containing 2-mercaptobenzimidazole, 2-mercaptobenzothiazole, and thioglycolic acid is higher than that in the case of traditional electroless plating baths, but the nickel consumption amount in the former case is lower. In order to minimize the waste water generated from electroless nickel-plating baths, we determined the lowest amounts of the chemicals that can be used for the concentrations reported in the literature.

  11. Use of fractal zone plates for transmission X-ray microscopy.

    Science.gov (United States)

    Ge, Xin; Wang, Zhili; Gao, Kun; Wang, Dajiang; Wu, Zhao; Chen, Jian; Pan, Zhiyun; Zhang, Kai; Hong, Youli; Zhu, Peiping; Wu, Ziyu

    2012-09-01

    In this contribution we discuss the possibility of designing a modified transmission X-ray microscope by using fractal zone plates (Fzps) as diffractive optical elements. In the modified transmission X-ray microscope optical layout, we first introduced a fractal zone plate as the microscope objective. Indeed, a fractal zone plate cannot only be used as an image-forming component but also as a condenser element to achieve an extended depth of field. Numerical analysis reveals that fractal zone plates and conventional Fresnel zone plates have similar imaging capabilities under different coherent illumination. Using a fractal zone plate as a condenser we also simulated axial irradiance. Results confirm that fractal zone plates can improve focusing capability with an extended depth of field. Although preliminary, these simulations clearly reveal that fractal zone plates, when available, will be of great help in microscope layouts, in particular for foreseen high-resolution applications in the "water window" as strongly required in biological research.

  12. Horizontal versus vertical plate motions

    Directory of Open Access Journals (Sweden)

    M. Cuffaro

    2006-07-01

    Full Text Available We review both present and past motions at major plate boundaries, which have the horizontal component in average 10 to 100 times faster (10–100 mm/yr than the vertical component (0.01–1 mm/yr in all geodynamic settings. The steady faster horizontal velocity of the lithosphere with respect to the upward or downward velocities at plate boundaries supports dominating tangential forces acting on plates. This suggests a passive role of plate boundaries with respect to far field forces determining the velocity of plates. The forces acting on the lithosphere can be subdivided in coupled and uncoupled, as a function of the shear at the lithosphere base. Higher the asthenosphere viscosity, more significant should be the coupled forces, i.e., the mantle drag and the trench suction. Lower the asthenosphere viscosity, more the effects of uncoupled forces might result determinant, i.e., the ridge push, the slab pull and the tidal drag. Although a combination of all forces acting on the lithosphere is likely, the decoupling between lithosphere and mantle suggests that a torque acts on the lithosphere independently of the mantle drag. Slab pull and ridge push are candidates for generating this torque, but, unlike these boundary forces, the advantage of the tidal drag is to be a volume force, acting simultaneously on the whole plates, and being the decoupling at the lithosphere base controlled by lateral variations in viscosity of the low-velocity layer.

  13. Horizontally oriented plates in clouds

    CERN Document Server

    Bréon, François-Marie

    2011-01-01

    Horizontally oriented plates in clouds generate a sharp specular reflectance signal in the glint direction, often referred to as "subsun". This signal (amplitude and width) may be used to analyze the relative area fraction of oriented plates in the cloud top layer and their characteristic tilt angle to the horizontal. We make use of spaceborne measurements from the POLDER instrument to provide a statistical analysis of these parameters. More than half of the clouds show a detectable maximum reflectance in the glint direction, although this maximum may be rather faint. The typical effective fraction (area weighted) of oriented plates in clouds lies between 10-3 and 10-2. For those oriented plates, the characteristic tilt angle is less than 1 degree in most cases. These low fractions imply that the impact of oriented plates on the cloud albedo is insignificant. The largest proportion of clouds with horizontally oriented plates is found in the range 500-700 hPa, in agreement with typical in situ observation of p...

  14. How mantle slabs drive plate tectonics.

    Science.gov (United States)

    Conrad, Clinton P; Lithgow-Bertelloni, Carolina

    2002-10-04

    The gravitational pull of subducted slabs is thought to drive the motions of Earth's tectonic plates, but the coupling between slabs and plates is not well established. If a slab is mechanically attached to a subducting plate, it can exert a direct pull on the plate. Alternatively, a detached slab may drive a plate by exciting flow in the mantle that exerts a shear traction on the base of the plate. From the geologic history of subduction, we estimated the relative importance of "pull" versus "suction" for the present-day plates. Observed plate motions are best predicted if slabs in the upper mantle are attached to plates and generate slab pull forces that account for about half of the total driving force on plates. Slabs in the lower mantle are supported by viscous mantle forces and drive plates through slab suction.

  15. Elasto-plastic postbuckling of damaged orthotropic plates

    Institute of Scientific and Technical Information of China (English)

    TIAN Yan-ping; FU Yi-ming

    2008-01-01

    Based on the elasto-plastic mechanics and continuum damage theory, a yield criterion related to spherical tensor of stress is proposed to describe the mixed hardening of damaged orthotropic materials. Its dimensionless form is isomorphic with the Mises criterion for isotropic materials. Furthermore, the incremental elasto-plastic damage constitutive equations and damage evolution equations are established. Based on the classical nonlinear plate theory, the incremental nonlinear equilibrium equations of orthotropic thin plates considering damage effect are obtained, and solved with the finite difference and iteration methods. In the numerical examples, the effects of damage evolution and initial deflection on the elasto-plastic postbuckling of orthotropic plates are discussed in detail.

  16. Recording Fractional Fourier Transform Hologram Using Holographic Zone Plate

    Institute of Scientific and Technical Information of China (English)

    高峰; 曾阳素; 张怡霄; 杨静; 高福华; 郭永康

    2002-01-01

    FRTH(fractional Fourier transform hologram) is a new kind of hologram that differs from common Fresnel holograms and Fourier transform holograms. Due to the flexibility of zone plate. A method that uses the -1 order diffraction wave of zone plate as the object wave and the 0 order diffraction wave as the reference wave to record FRTH is presented. It provides a new simple way to record FRTH. In this paper, the theory of achieving FRT and recording FRTH using holographic zone plate is presented and experimental results are given.

  17. Corrosion of Cast Iron Mill Plates in Wet Grinding

    Directory of Open Access Journals (Sweden)

    Anthony ANDREWS

    2010-12-01

    Full Text Available Corrosion studies were carried out on two different maize grinding plates. Maize was soaked in water for three days and the water decanted and used as electrolyte. Mass loss and pH measurements were carried out every 3 days for 15-day period. Results show that, for each plate, mass loss and pH increased with exposure time. Corrosion rates determined from mass loss data was found to be strongly dependent on pH. The observed behaviour may be explained in terms of the chemical composition and/or microstructures of the plates. Results are briefly discussed in terms of the contribution of corrosion to wear.

  18. Estimating area of inclusions in anisotropic plates from boundary data

    CERN Document Server

    Morassi, Antonino; Vessella, Sergio

    2011-01-01

    We consider the inverse problem of determining the possible presence of an inclusion in a thin plate by boundary measurements. The plate is made by non-homogeneous linearly elastic material belonging to a general class of anisotropy. The inclusion is made by different elastic material. Under some a priori assumptions on the unknown inclusion, we prove constructive upper and lower estimates of the area of the unknown defect in terms of an easily expressed quantity related to work, which is given in terms of measurements of a couple field applied at the boundary and of the induced transversal displacement and its normal derivative taken at the boundary of the plate.

  19. The postbuckling analysis of laminated circular plate with elliptic delamination

    Science.gov (United States)

    Chen, Deliang; Chen, Changping; Fu, Yiming

    2011-01-01

    Based on the Von Karman plate theory, considering the effect of transverse shear deformation, and using the method of the dissociated three regions, the postbuckling governing equations for the axisymmetric laminated circular plates with elliptical delamination are derived. By using the orthogonal point collocation method, the governing equations, boundary conditions and continuity conditions are transformed into a group of nonlinear algebraically equation and the equations are solved with the alternative method. In the numerical examples, the effects of various elliptical in shape, delamination depth and different material properties on buckling and postbuckling of the laminated circular plates are discussed and the numerical results are compared with available data.

  20. Free vibration analysis of Mindlin plates with linearly varying thickness

    Science.gov (United States)

    Aksu, G.; Al-Kaabi, S. A.

    1987-12-01

    A method based on the variational principles in conjunction with the finite difference technique is applied to examine the free vibration characteristics of isotropic rectangular plates of linearly varying thickness by including the effects of transverse shear deformation and rotary inertia. The validity of the present approach is demonstrated by comparing the results with other solutions proposed for plates with uniform and linearly varying thickness. Natural frequencies and mode shapes of Mindlin plates with simply supported and clamped edges are determined for various values of relative thickness ratio and the taper thickness constant.

  1. Geometry of the Cocos Plate Under North American Plate

    Science.gov (United States)

    Perez-Campos, X.

    2015-12-01

    The Cocos plate subducts under the North American plate with a complex geometry, and previous seismicity studies revealed some of this complexity. However, details of the geometry and the depth that the plate penetrates werelargely unknown. Since 2004, temporary experiments and the expansion of the permanent network of the Servicio Sismológico Nacional (SSN, Mexican National Seismological Service) have improved resolution of the plate geometry and have helped to map its descent into the upper mantle. Going from northwest to southeast, the Cocos plate appears to be fragmenting into north and south segments. The north segment subducts with an angle of ~30º and the south with an angle of ~10-15º. The transition is smooth near the trench and progresses to a tear at depth; this coincides with the projection of the Orozco Fracture Zone to depth. Also, this transition marks the limit of the presence to the south of an ultra slow velocity layer (USL) on top of the slab.South of this transition, the Cocos plate subducts horizontally , underplating the North American plate for a distance of ~140 to ~300 km from the trench. Along this horizontal region, silent slow events (SSE) and tectonic tremor (TT) have been observed. At a distance of 300 km from the trench (beneath central Mexico), the plate dives into the mantle with an angle of 76º to a depth of 500 km. This geometry changes abruptly to the south, marking the eastern limit of the USL. This change seems to be also characterized by a tear on the slab. Finally to the south, the Cocos plate subducts with a constant angle of 26º. This presentation summarizes the work of many contributors including A. Arciniega-Ceballos, M. Brudzinski, E. Cabral-Cano, T. Chen, R. Clayton,F. Cordoba-Montiel,P. Davis,S. Dougherty,F. Green, M. Gurnis, D. V. Helmberger, A. Husker,A. Iglesias, Y. Kim, V. Manea, D. Melgar, M. Rodríguez-Domínguez,S. K. Singh, T.-R. A. Song, C. M. Valdés-González, D. Valencia-Cabrera

  2. Experiments on elastic cloaking in thin plates.

    Science.gov (United States)

    Stenger, Nicolas; Wilhelm, Manfred; Wegener, Martin

    2012-01-06

    Following a theoretical proposal [M. Farhat et al., Phys. Rev. Lett. 103, 024301 (2009)], we design, fabricate, and characterize a cloaking structure for elastic waves in 1 mm thin structured polymer plates. The cloak consists of 20 concentric rings of 16 different metamaterials, each being a tailored composite of polyvinyl chloride and polydimethylsiloxane. By using stroboscopic imaging with a camera from the direction normal to the plate, we record movies of the elastic waves for monochromatic plane-wave excitation. We observe good cloaking behavior for carrier frequencies in the range from 200 to 400 Hz (one octave), in good agreement with a complete continuum-mechanics numerical treatment. This system is thus ideally suited for demonstration experiments conveying the ideas of transformation optics.

  3. Interim Report on Mixing During the Casting of LEU-10Mo Plates in the Triple Plate Molds

    Energy Technology Data Exchange (ETDEWEB)

    Aikin, Jr., Robert M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-04-12

    LEU-10%Mo castings are commonly produced by down blending unalloyed HEU with a DU-12.7%Mo master-alloy. This work uses process modeling to provide insight into the mixing of the unalloyed uranium and U-Mo master alloy during melting and mold filling of a triple plate casting. Two different sets of situations are considered: (1) mixing during mold filling from a compositionally stratified crucible and (2) convective mixing of a compositionally stratified crucible during mold heating. The mold filling simulations are performed on the original Y-12 triple plate mold and the horizontal triple plate mold.

  4. A Robust and Efficient Approach to License Plate Detection.

    Science.gov (United States)

    Yuan, Yule; Zou, Wenbin; Zhao, Yong; Wang, Xinan; Hu, Xuefeng; Komodakis, Nikos

    2017-03-01

    This paper presents a robust and efficient method for license plate detection with the purpose of accurately localizing vehicle license plates from complex scenes in real time. A simple yet effective image downscaling method is first proposed to substantially accelerate license plate localization without sacrificing detection performance compared with that achieved using the original image. Furthermore, a novel line density filter approach is proposed to extract candidate regions, thereby significantly reducing the area to be analyzed for license plate localization. Moreover, a cascaded license plate classifier based on linear support vector machines using color saliency features is introduced to identify the true license plate from among the candidate regions. For performance evaluation, a data set consisting of 3977 images captured from diverse scenes under different conditions is also presented. Extensive experiments on the widely used Caltech license plate data set and our newly introduced data set demonstrate that the proposed approach substantially outperforms state-of-the-art methods in terms of both detection accuracy and run-time efficiency, increasing the detection ratio from 91.09% to 96.62% while decreasing the run time from 672 to 42 ms for processing an image with a resolution of 1082×728 . The executable code and our collected data set are publicly available.

  5. Analytical solution for multilayer plates using general layerwise plate theory

    Directory of Open Access Journals (Sweden)

    Vuksanović Đorđe M.

    2005-01-01

    Full Text Available This paper deals with closed-form solution for static analysis of simply supported composite plate, based on generalized laminate plate theory (GLPT. The mathematical model assumes piece-wise linear variation of in-plane displacement components and a constant transverse displacement through the thickness. It also include discrete transverse shear effect into the assumed displacement field, thus providing accurate prediction of transverse shear stresses. Namely, transverse stresses satisfy Hook's law, 3D equilibrium equations and traction free boundary conditions. With assumed displacement field, linear strain-displacement relation, and constitutive equations of the lamina, equilibrium equations are derived using principle of virtual displacements. Navier-type closed form solution of GLPT, is derived for simply supported plate, made of orthotropic laminae, loaded by harmonic and uniform distribution of transverse pressure. Results are compared with 3D elasticity solutions and excellent agreement is found.

  6. Random vibrations of composite beams and plates

    Science.gov (United States)

    Abdelnaser, Ahmad Shehadeh

    numerical results obtained with various deformation theories for the frequencies as well as response quantities are compared to evaluate the effect of the shear deformations. For thicker and rigid beams and plates, one observes large differences in the frequencies and responses obtained with (the first and third-order shear deformation theories) and without consideration of shear deformations (classical theory). For the frequencies and global responses, both the first and third-order theories give about the same results.

  7. 不同构造措施的钢管混凝土边框钢板剪力墙抗震性能试验研究%Experimental Study on Seismic Performance of Steel-plate Shear Walls with Concrete Filled Steel Tube Columns and Different Constructional Measures

    Institute of Scientific and Technical Information of China (English)

    张建伟; 曹万林; 董宏英; 李刚; 张文江

    2011-01-01

    The steel-plate shear wall with concrete filled steel tube columns is a new type of composite shear wall. In order to assess the seismic performance of new shear walls with different constructional measures, experimental study of three specimens with the same shear span ratio 1-5 were carried out undercyclic loading: one with the steel plate and the steel tubes being connected by welding, one with the steel plate and the steel tubes being connected by bolts, and one with the steel plate and the steel tubes being connected by welding as well as with low opening ratio of holes in the steel plate. Based on the experiment , the damage characteristics, hysteretic behavior, load-carrying capacity, stiffness, ductility and energy dissipation of the specimens were contrastively analyzed. The experimental results showed that the connection type between the steel plate and the steel tubes, either in welding or in bolting, had little effect on the overall performance of the shear walls. Compare to the normal steel-plate shear walls with concrete filled steel tube columns, the load-carrying capacity, ductility, stiffness and energy dissipation of the perforated steel-plate shear walls with concrete filled steel tube columns had not obvious change under low opening ratio of holes.%钢管混凝土边框钢板剪力墙是一种新型抗震剪力墙,为了比较不同构造措施对该新型剪力墙抗震性能的影响,进行了3个剪跨比为1.5的钢管混凝土边框钢板剪力墙低周反复荷载试验.其中,试验模型1为墙体钢板与边框柱钢管焊接,试验模型2为墙体钢板与边框柱钢管螺栓连接,试验模型3为墙体钢板开孔并与边框柱钢管焊接.通过试验研究,比较了各剪力墙的破坏特征、滞回特性、承载力、刚度、延性以及耗能能力.结果表明:在墙体钢板与边框柱钢管的连接方式中,采用焊接或栓接对剪力墙的整体性能影响不大;与普通钢管混凝土边框钢板剪力墙相

  8. Plate tectonics of the Mediterranean region.

    Science.gov (United States)

    McKenzie, D P

    1970-04-18

    The seismicity and fault plane solutions in the Mediterranean area show that two small rapidly moving plates exist in the Eastern Mediterranean, and such plates may be a common feature of contracting ocean basins. The results show that the concepts of plate tectonics apply to instantaneous motions across continental plate boundaries.

  9. 30 CFR 18.13 - Certification plate.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Certification plate. 18.13 Section 18.13... Certification plate. Each certified component shall be identified by a certification plate attached to the... characteristics of the component. The plate shall be of serviceable material, acceptable, to MSHA, and shall...

  10. 21 CFR 872.4760 - Bone plate.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bone plate. 872.4760 Section 872.4760 Food and... DENTAL DEVICES Surgical Devices § 872.4760 Bone plate. (a) Identification. A bone plate is a metal device... plate with screws to prevent movement of the segments. (b) Classification. Class II. ...

  11. 30 CFR 18.11 - Approval plate.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approval plate. 18.11 Section 18.11 Mineral... plate. (a)(1) The notice of approval will be accompanied by a photograph of an approval plate, bearing... number shall be added to the original approval number on the approval plate. (Example: Original approval...

  12. Create Your Plate

    Medline Plus

    Full Text Available ... vegetables represented in this tool is not to scale because of the differences in types of vegetables. ... news, research and food & fitness tips. Email: Sign Up Thank you for signing up ' + ' '); $('.survey-form').show(); }, ...

  13. Beyond plate tectonics - Looking at plate deformation with space geodesy

    Science.gov (United States)

    Jordan, Thomas H.; Minster, J. Bernard

    1988-01-01

    The requirements that must be met by space-geodetic systems in order to constrain the horizontal secular motions associated with the geological deformation of the earth's surface are explored. It is suggested that in order to improve existing plate-motion models, the tangential components of relative velocities on interplate baselines must be resolved to an accuracy of less than 3 mm/yr. Results indicate that measuring the velocities between crustal blocks to + or - 5 mm/yr on 100-km to 1000-km scales can produce geologically significant constraints on the integrated deformation rates across continental plate-boundary zones such as the western United States.

  14. Plating on some difficult-to-plate metals and alloys

    Energy Technology Data Exchange (ETDEWEB)

    Dini, J.W.; Johnson, H.R.

    1980-02-01

    Electrodeposition of coatings on metals such as beryllium, beryllium-copper, Kovar, lead, magnesium, thorium, titanium, tungsten, uranium, zirconium, and their alloys can be problematic. This is due in most cases to a natural oxide surface film that readily reforms after being removed. The procedures we recommend for plating on these metals rely on replacing the oxide film with a displacement coating, or etching to allow mechanical keying between the substrate and plated deposit. The effectiveness of the procedures is demonstrated by interface bond strengths found in ring-shear and conical-head tensile tests.

  15. Beyond plate tectonics - Looking at plate deformation with space geodesy

    Science.gov (United States)

    Jordan, Thomas H.; Minster, J. Bernard

    1988-01-01

    The requirements that must be met by space-geodetic systems in order to constrain the horizontal secular motions associated with the geological deformation of the earth's surface are explored. It is suggested that in order to improve existing plate-motion models, the tangential components of relative velocities on interplate baselines must be resolved to an accuracy of less than 3 mm/yr. Results indicate that measuring the velocities between crustal blocks to + or - 5 mm/yr on 100-km to 1000-km scales can produce geologically significant constraints on the integrated deformation rates across continental plate-boundary zones such as the western United States.

  16. Thermal performance optimization of a flat plate solar air heater using genetic algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Varun; Siddhartha [Department of Mechanical Engineering, National Institute of Technology, Hamirpur 177 005 (H.P.) (India)

    2010-05-15

    Thermal performance of solar air heater is low and different techniques are adopted to increase the performance of solar air heaters, such as: fins, artificial roughness etc. In this paper an attempt has been done to optimize the thermal performance of flat plate solar air heater by considering the different system and operating parameters to obtain maximum thermal performance. Thermal performance is obtained for different Reynolds number, emissivity of the plate, tilt angle and number of glass plates by using genetic algorithm. (author)

  17. Interacting wakes of a narrow and a wide flat plate in tandem arrangement

    Energy Technology Data Exchange (ETDEWEB)

    Hacışevki, H; Teimourian, A, E-mail: hasan.hacisevki@emu.edu.tr [Department of Mechanical Engineering, Eastern Mediterranean University, Mağusa, North Cyprus, Mersin 10 (Turkey)

    2016-02-15

    Flow structures behind two different sized flat plates in tandem arrangement normal to flow at high Reynolds number have been investigated experimentally. A narrow flat plate, as a control plate, has been placed upstream of a wide plate to investigate the interacting wakes behind the wide flat plate. The near wake downstream of the wide plate has been measured by employing constant-temperature hot wire anemometer, quantitatively. The effects of different width ratio (h/D) range from 0.1 to 1.0 together with gap ratio (g/D) ranging from 0.5 to 2.0 have been probed. It was found that Strouhal number variation is directly proportional to gap ratio between the plates. Moreover, it was observed that turbulent kinetic energy production is mostly contributed by transverse normal turbulent stress and therefore follows the transverse stress pattern rather than the stream wise stress. (paper)

  18. Water wave scattering by an elastic thin vertical plate submerged in finite depth water

    Science.gov (United States)

    Chakraborty, Rumpa; Mandal, B. N.

    2013-12-01

    The problem of water wave scattering by a thin vertical elastic plate submerged in uniform finite depth water is investigated here. The boundary condition on the elastic plate is derived from the Bernoulli-Euler equation of motion satisfied by the plate. Using the Green's function technique, from this boundary condition, the normal velocity of the plate is expressed in terms of the difference between the velocity potentials (unknown) across the plate. The two ends of the plate are either clamped or free. The reflection and transmission coefficients are obtained in terms of the integrals' involving combinations of the unknown velocity potential on the two sides of the plate, which satisfy three simultaneous integral equations and are solved numerically. These coefficients are computed numerically for various values of different parameters and depicted graphically against the wave number in a number of figures.

  19. Energy flow in plate assembles by hierarchical version of finite element method

    DEFF Research Database (Denmark)

    Wachulec, Marcin; Kirkegaard, Poul Henning

    method has been proposed. In this paper a modified hierarchical version of finite element method is used for modelling of energy flow in plate assembles. The formulation includes description of in-plane forces so that planes lying in different planes can be modelled. Two examples considered are: L......-corner of two rectangular plates an a I-shaped plate girder made of five plates. Energy distribution among plates due to harmonic load is studied and the comparison of performance between the hierarchical and standard finite element formulation is presented....

  20. The Studies of Composite Electroless Plating Process on Sintering Ndfeb Permanent Magnet

    Institute of Scientific and Technical Information of China (English)

    HU Jian-wen; MA Jing; YAN Dong-qing; GAO Qing; MENG Yong-qiang

    2004-01-01

    A reasonable pre-treatment and an ultrasonic pre-plating Cu film were applied for sintering NdFeB permanent magnet. The samples were then plated in neutral bath (PH=7) for 40min and in acidic bath (PH=4.8~5.1) for 2h. A composite electroless plating with different phosphor content was obtained. The results show that the composite plating coatings are dense and have a strong bond with the substrate, which contribute to the excellent corrosion resistance of the plating coating.

  1. The Studies of Composite Electroless Plating Process on Sintering Ndfeb Permanent Magnet

    Institute of Scientific and Technical Information of China (English)

    HUJian-wen; MAJing; YANDong-qing; GAOQing; MENGYong-qiang

    2004-01-01

    A reasonable pre-treatment and an ultrasonic pre-plating Cu film were applied for sintering NdFeB permanent magnet. The samples were then plated in neutral bath (PH=7) for 40rnin and in acidic bath (PH=4.8-5.1) for 2h. A composite electroless plating with different phosphor content was obtained. The results show that the composite plating coatings are dense and have a strong bond with the substrate, which contribute to the excellent corrosion resistance of the plating coating.

  2. [Angle-fixed plate fixation or double-plate osteosynthesis in fractures of the proximal humerus: a biomechanical study].

    Science.gov (United States)

    Hessmann, Martin H; Korner, Jan; Hofmann, Alexander; Sternstein, Werner; Rommens, Pol M

    2008-06-01

    Internal fixation of fractures of the proximal humerus needs a high stability of fixation to avoid secondary loss of fixation. This is especially important in osteoporotic bone. In an experimental study, the biomechanical properties of the angle-fixed Philos plate (internal fixator) and a double-plate osteosynthesis using two one-third tubular plates were assessed. The fracture model was an unstable three-part fracture (AO type B2). Eight pairs of human cadaveric humeri were submitted to axial load and torque. In the first part of the study, it was assessed to which degree the original stiffness of the humeri could be restored after the osteotomy by the osteosynthesis procedure. Subsequently, subsidence during 200 cycles of axial loading and torque was analysed. During axial loading, the Philos plate was significantly stiffer and showed less irreversible deformation. Two double-plate fixations, but none of the Philos plate osteosynthesis, failed. During torsion, there were no significant differences between the two implants. From the biomechanical point of view, the angle-fixed Philos plate represents the implant of choice for the surgical fixation of highly unstable three-part fractures of the proximal humerus, as the internal fixator system is characterised by superior biomechanical properties.

  3. Multiregional evaluation of the SimPlate heterotrophic plate count method compared to the standard plate count agar pour plate method in water.

    Science.gov (United States)

    Jackson, R W; Osborne, K; Barnes, G; Jolliff, C; Zamani, D; Roll, B; Stillings, A; Herzog, D; Cannon, S; Loveland, S

    2000-01-01

    A new SimPlate heterotrophic plate count (HPC) method (IDEXX Laboratories, Westbrook, Maine) was compared with the pour plate method at 35 degrees C for 48 h. Six laboratories tested a total of 632 water samples. The SimPlate HPC method was found to be equivalent to the pour plate method by regression analysis (r = 0. 95; y = 0.99X + 0.06).

  4. Multiregional Evaluation of the SimPlate Heterotrophic Plate Count Method Compared to the Standard Plate Count Agar Pour Plate Method in Water

    OpenAIRE

    Jackson, R. Wayne; Osborne, Karen; Barnes, Gary; Jolliff, Carol; Zamani, Dianna; Roll, Bruce; Stillings, Amy; Herzog, David; Cannon, Shelly; Loveland, Scott

    2000-01-01

    A new SimPlate heterotrophic plate count (HPC) method (IDEXX Laboratories, Westbrook, Maine) was compared with the pour plate method at 35°C for 48 h. Six laboratories tested a total of 632 water samples. The SimPlate HPC method was found to be equivalent to the pour plate method by regression analysis (r = 0.95; y = 0.99X + 0.06).

  5. Multiple-Dynode-Layer Microchannel Plate

    Science.gov (United States)

    Woodgate, Bruce E.

    1990-01-01

    Improved microchannel-plate electron image amplifier made of stack of discrete microchannel-plate layers. New plates easier to manufacture because no need to etch long, narrow holes, to draw and bundle thin glass tubes, or to shear plates to give microchannels curvatures necessary for reduction of undesired emission of ions. Discrete dynode layers stacked with slight offset from layer to layer to form microchannel plate with curved channels. Provides for relatively fast recharging of microchannel dynodes, with consequent enhancement of performance.

  6. Locking plates in proximal humerus fractures.

    Science.gov (United States)

    Strohm, P C; Helwig, P; Konrad, G; Südkamp, N P

    2007-12-01

    It is well known that proximal humerus fractures are among the three most frequent fracture types. Epidemiological invetsigations show that in people elder than 60 years the fracture of the proximal humerus is more frequent than fractures of the hip region (17). Over the last decades several techniques have been applied for treatment of proximal humerus fractures. Widely accepted is the initiation of a conservative treatment regimen for undisplaced fractures, however, the standard treatment for displaced fractures, especially three and four part fractures, is still the center of scientific debate. Many different implants have been tested and investigated, thus demonstrating lack of sufficient results. Over the last years the development of angle stable, locking implants started and clinical studies demonstrated encouraging results. In our clinic the locking proximal humerus plate and the PHILOS plate advanced to the implant of choice for treatment of displaced proximal humerus fractures. There are still cases of implant failure and humerus head necrosis, but most of these complications were caused by the fracture type and not an implant specific problem. However the overall results with these new implants are encouraging. Key words: locking plates, proximal humerus fracture, humerus, humerus fracture, PHILOS, PHP.

  7. Theoretical Investigation of Calculating Temperatures in the Combining Zone of Cu/Fe Composite Plate Jointed by Explosive Welding

    Science.gov (United States)

    Qu, Y. D.; Zhang, W. J.; Kong, X. Q.; Zhao, X.

    2016-03-01

    The heat-transfer behavior of the interface of Flyer plate (or Base Plate) has great influence on the microcosmic structures, stress distributions, and interface distortion of the welded interface of composite plates by explosive welding. In this paper, the temperature distributions in the combing zone are studied for the case of Cu/Fe composite plate jointed by explosive welding near the lower limit of explosive welding. The results show that Flyer plate (Cu plate) and Base Plate (Fe plate) firstly almost have the same melting rate in the explosive welding process. Then, the melting rate of Cu plate becomes higher than that of Fe plate. Finally, the melt thicknesses of Cu plate and Fe plate trend to be different constants, respectively. Meanwhile, the melting layer of Cu plate is thicker than that of Fe plate. The research could supply some theoretical foundations for calculating the temperature distribution and optimizing the explosive welding parameters of Cu/Fe composite plate to some extent.

  8. 非加劲钢板剪力墙国内外设计方法比较分析%Comparative study on design methods for unstiffened steel plate shear wall in different codes

    Institute of Scientific and Technical Information of China (English)

    徐建; 石永久; 戴国欣; 王元清; 杨蔚彪

    2012-01-01

    钢板剪力墙已在高层建筑中开始得到应用,国外已有钢板剪力墙的设计规范,但中国对钢板剪力墙的设计方法规定还比较保守,其设计准则仍基于厚钢板墙的设计理念.本文根据美国规范AISC-341 2005、加拿大规范CAN/CSA S16-01以及中国的高层建筑规程对非加劲钢板剪力墙的设计过程进行了对比,对墙板的抗剪承载力,尤其是对薄板屈曲后形成拉力场的性能进行了相关实例的计算,并对设计结果进行了比较.结果表明,美国和加拿大规范在高厚比较大时,能较准确反映墙板的抗剪承载力;中国规范只是在高厚比较小时能准确计算其抗剪承载力,高厚比较大时,既不准确,也不经济.%Steel Plate Shear Wall( short for SPSW) structures are beginning being used in structural application. Until now,there have been several design codes for unstiffened SPSW at abroad. However,such a specification on SPSW been prescribed in China is more conservative,whose design criteria is still based on the concept of thick SPSW design. According to American (AISC -341 2005) , Canadian (CAN/CSA S16 -01) and Chinese high-rise building regulations, the unstiffened SPSW was contrasted in the design process. The related example in calculations was given and the results of the design were compared. The item to be calculated here is the shear resistance, especially the postbuckling strength after the thin wall buckling and forming the tension field. The results show that the correlative provision in America and Canada can more accurately reflect the shear resistance of the wall with large height-thickness ratio. However,the provision in China can only accurately reflect it with small height-thickness ratio, which is not accurate or economical for thin plate wall.

  9. Anatomic security of applying different numbers of screws at the sacrum sides in the anterior double plate fixation of the sacroiliac joint%骶髂关节前路双钢板固定骶骨侧不同螺钉数量的解剖安全性研究

    Institute of Scientific and Technical Information of China (English)

    刘佳; 高仕长; 倪卫东; 蒋电明; 周程鹏

    2012-01-01

    0bjective: To compare the anatomic security of applying different numbers of screws at the sacrum sides in the anterior double plates fixation of the sacruiliac joint and to clarify which is safer when the stability of the fixation is considered. Methods: (1) Totally 15 normal cadavers pelvis were scanned by CT. Thin-section CT scan data were saved and analyzed by the software Materi-alise's interactive medical image control system (MIMICS 10.0). The virtual operations of the anterior double plates approach for fixation of the sacroiliac joint were performed in the same software. (2)The left sides of the sacroiliac joint were named as group A,in which two screws were placed into the sacrum sides. The right sides of the sacroiliac joint were named as group B,in which one screw was placed into the sacrum sides. The distances from the medial edge of the plates to the lateral sides of the anterior branches of lumbar nerves 4,5 were measured. The relationship of the screws and the sacroiliac joint was checked by radiograph. Results: (1 )In the virtual operations,the sacrum sides can accommodate two screws safely- (2)In group A,the distances from the medial edge of the upper and lower plates to the lateral sides of the anterior branches of lumbar nerve 5 were (3.0 ± 1.4) mm and (1.5 ± 1.0) mm respectively. The upper and lower plates can be placed below the anterior branches of lumbar nerve 4 safely. In group B,the distances from the medial edge of the upper plates to the lateral sides of the anterior branches of lumbar nerves 4,5 were (5.0 ± 1.1) mm and (10.3 ±1.3) mm respectively and those from the medial edge of the lower plates were (2.7 ± 0.5) mm and (5.1 ±0.9) nun respectively. (3)ln X-ray examination,no screw of the left upper plates was found in the sacroiliac joint in group A and 4 screws of the left lower plates were observed. On the other hand, no screw of the right plates (lower and upper) in the group B was found in the sacroiliac joint. Conclusions

  10. COMPARATIVE STUDY OF FOREARM FRACTURES TREATED WITH LOCKING COMPRESSION PLATE LIMITED CONTACT DYNAMIC COMPRESSION PLATE

    Directory of Open Access Journals (Sweden)

    Jayachandra Reddy

    2015-02-01

    Full Text Available OBJECTIVES: This study has been carried out to compare the functional outcome of fracture fixation in diaphyseal forearm fractures by using Locking Compression Plate versus Limited contact dynamic compression Plate. To study the difference in the duration of union & complications with LCP & LC - DCP. METHODOLOGY: It is a prospective randomised comparative study which was carried out from December 2012 to December 2014 in our In stitution. In Group I, 20 patients were subjected to open reduction and internal fixation with 3.5 mm stainless steel LCP and locking head/nonlocking screws. In Group II, 20 patients were managed by 3.5mm LCDCP and non - locking screws. Clinical assessments regarding pain and function, radiological assessments were undertaken at the final follow - up. RESULTS - The time required for LCP fixation (mean 93.5 min, range 75 - 120 min was found to be more than that required for LC - DCP (mean 81.94 min, range 60 - 110 mi n. But this time difference was not significant (P=0.07, unpaired t test. The mean time of union for the forearm fixed with LCP was found to be 18 weeks (range 14 - 26 weeks in comparison to 16 weeks (range 10 - 22 weeks for the LC - DCP group. CONCLUSION - LC plating is an effective treatment option for fractures shaft of forearm. The present study could not prove the superiority of LCP over LC - DCP. It is the proper application of the principles of plating and not the type of plate which decides the outco me. Further long - term multicentric study is required to prove behaviors of the implant.

  11. Changes in Flat Plate Wake Characteristics Obtained With Decreasing Plate Thickness

    Science.gov (United States)

    Rai, Man Mohan

    2016-01-01

    The near and very near wake of a flat plate with a circular trailing edge is investigated with data from direct numerical simulations. Computations were performed for four different Reynolds numbers based on plate thickness (D) and at constant plate length. The value of ?/D varies by a factor of approximately 20 in the computations (? being the boundary layer momentum thickness at the trailing edge). The separating boundary layers are turbulent in all the cases. One objective of the study is to understand the changes in wake characteristics as the plate thickness is reduced (increasing ?/D). Vortex shedding is vigorous in the low ?/D cases with a substantial decrease in shedding intensity in the largest ?/D case (for all practical purposes shedding becomes almost intermittent). Other characteristics that are significantly altered with increasing ?/D are the roll-up of the detached shear layers and the magnitude of fluctuations in shedding period. These effects are explored in depth. The effects of changing ?/D on the distributions of the time-averaged, near-wake velocity statistics are discussed.

  12. Plate-like osteoma cutis.

    Science.gov (United States)

    Orme, Charisse M; Hale, Christopher S; Meehan, Shane A; Long, Wendy

    2014-12-16

    Osteoma cutis is the aberrant development of bone within the skin. The bone formation may be de novo (primary) or result from an injury to the skin (secondary). Here we present a healthy 53-year-old man with no known abnormalities in calcium or phosphate metabolism with plate-like osteoma cutis of the scalp. Plate- or plaque-like osteoma cutis was initially described as a congenital condition but has now been reported several times in the literature as an idiopathic process that occurs in adults. Treatment options are limited and are only required if the lesion is bothersome to the patient.

  13. Hydroelasticity of a Floating Plate

    DEFF Research Database (Denmark)

    Chen, X.; Jensen, Jørgen Juncher; Cui, W.

    2003-01-01

    The membrane forces are included in the hydroelastic analysis of a floating plate undergoing large vertical deflections in regular monochromatic multidirectional waves. The first-order vertical displacements induced by the linear wave exciting forces are calculated by the mode expansion method...... in the frequency domain. The second-order vertical displacements induced by the membrane forces are calculated by the von Karman plate theory. The results show that the membrane contribution both in terms of the axial stresses and the effect on the bending stresses can be important...

  14. Orifice plates and venturi tubes

    CERN Document Server

    Reader-Harris, Michael

    2015-01-01

    This book gives the background to differential-pressure flow measurement and goes through the requirements explaining the reason for them. For those who want to use an orifice plate or a Venturi tube the standard ISO 5167 and its associated Technical Reports give the instructions required.  However, they rarely tell the users why they should follow certain instructions.  This book helps users of the ISO standards for orifice plates and Venturi tubes to understand the reasons why the standards are as they are, to apply them effectively, and to understand the consequences of deviations from the standards.

  15. Multilayer Clad Plate of Stainless Steel/Aluminum/Aluminum Alloy

    Institute of Scientific and Technical Information of China (English)

    YUAN Jiawei; PANG Yuhua; LI Ting

    2011-01-01

    The 3, 5, 20 layer clad plate from austenitic stainless steel, pure aluminum and aluminum alloy sheets were fabricated in different ways. The stretch and interface properties were measured. The result shows that 20 layer clad plate is better than the others. Well-bonded clad plate was successfully obtained in the following procedure: Basic clad sheet from 18 layer A11060/A13003sheets was firstly obtained with an initial rolling reduction of 44% at 450 ℃, followed by annealing at 300 ℃, and then with reduction of 50% at 550 ℃ from STS304 on each side. The best 20 layer clad plate was of 129 MPa bonding strength and 225 MPa stretch strength.

  16. FRACTURE CALCULATION OF BENDING PLATES BY BOUNDARY COLLOCATION METHOD

    Institute of Scientific and Technical Information of China (English)

    王元汉; 伍佑伦; 余飞

    2003-01-01

    Fracture of Kirchhoff plates is analyzed by the theory of complex variables and boundary collocation method. The deflections, moments and shearing forces of the plates are assumed to be the functions of complex variables. The functions can satisfy a series of basic equations and governing conditions, such as the equilibrium equations in the domain, the boundary conditions on the crack surfaces and stress singularity at the crack tips. Thus, it ts only necessary to consider the boundary conditions on the external boundaries of the plate, which can be approximately satisfied by the collocation method and least square technique. Different boundary conditions and loading cases of the cracked plates are analyzed and calculated. Compared to other methods, the numerical examples show that the present method has many advantages such as good accuracy and less computer time This is an effective semi-analytical and semi-numerical method.

  17. Outer rise seismicity of the subducting Nazca Plate: Plate stress distribution, fault orientation and plate hydration

    Science.gov (United States)

    Barama, Louisa

    Subduction of the Nazca plate beneath the South American plate drives frequent and sometimes large magnitude earthquakes. During the past 40 years, significant numbers of outer rise earthquakes have occurred in the offshore regions of Colombia and Chile. In this study, we investigate the distribution of stress due to lithospheric bending and the extent of faults within the subducting plate. To calculate more accurate epicenters and to constrain which earthquakes occurred within the outer rise, we use hypocentroidal decomposition to relocate earthquakes with Global Centroid Moment Tensor (GCMT) solutions occurring after 1976 offshore Colombia and Chile. We determine centroid depths of outer rise earthquakes by inverting teleseismic P-, SH-, and SV- waveforms for earthquakes occurring from 1993 to 2014 with Mw ≥ 5.5. In order to further constrain the results of the waveform inversion, we estimate depths by comparing earthquake duration, amplitude, and arrival times for select stations with waveforms with good signal to noise ratios. Our results indicate that tensional earthquakes occur at depths down to 13 km and 24 km depth beneath the surface in the Colombia and Chile regions, respectively. Since faulting within the outer rise can make the plate susceptible to hydration and mantle serpentinization, we therefore infer the extent of possible hydration of the Nazca plate to extend no deeper than the extent of tensional outer rise earthquakes.

  18. Light splitting with imperfect wave plates.

    Science.gov (United States)

    Jackson, Jarom S; Archibald, James L; Durfee, Dallin S

    2017-02-01

    We discuss the use of wave plates with arbitrary retardances, in conjunction with a linear polarizer, to split linearly polarized light into two linearly polarized beams with an arbitrary splitting fraction. We show that for non-ideal wave plates, a much broader range of splitting ratios is typically possible when a pair of wave plates, rather than a single wave plate, is used. We discuss the maximum range of splitting fractions possible with one or two wave plates as a function of the wave plate retardances, and how to align the wave plates to achieve the maximum splitting range possible when simply rotating one of the wave plates while keeping the other one fixed. We also briefly discuss an alignment-free polarization rotator constructed from a pair of half-wave plates.

  19. Effects of a sliding plate on morphology of the epiphyseal plate in goat distal femur.

    Science.gov (United States)

    Lin, Da-sheng; Lian, Ke-jian; Hong, Jia-yuan; Ding, Zhen-qi; Zhai, Wen-liang

    2012-01-01

    The aim of this study was to observe the effects of a sliding plate on the morphology of the epiphyseal plate in goat distal femur. Eighteen premature female goats were divided randomly into sliding plate, regular plate and control groups. Radiographic analysis and histological staining were performed to evaluate the development of epiphyseal plate at 4 and 8 weeks after surgery. In the sliding plate group, the plate extended accordingly as the epiphyseal plate grows, and the epiphyseal morphology was kept essential normal. However, the phenomenon of the epiphyseal growth retardation and premature closure were very common in the regular plate group. In addition, the sliding plate group exhibited more normal histologic features and Safranin O staining compared to the regular plate group. Our results suggest that the sliding plate can provide reliable internal fixation of epiphyseal fracture without inhibiting epiphyseal growth.

  20. Effects of a Sliding Plate on Morphology of the Epiphyseal Plate in Goat Distal Femur

    Directory of Open Access Journals (Sweden)

    Da-sheng LIN, Ke-jian LIAN, Jia-yuan HONG, Zhen-qi DING, Wen-liang ZHAI

    2012-01-01

    Full Text Available The aim of this study was to observe the effects of a sliding plate on the morphology of the epiphyseal plate in goat distal femur. Eighteen premature female goats were divided randomly into sliding plate, regular plate and control groups. Radiographic analysis and histological staining were performed to evaluate the development of epiphyseal plate at 4 and 8 weeks after surgery. In the sliding plate group, the plate extended accordingly as the epiphyseal plate grows, and the epiphyseal morphology was kept essential normal. However, the phenomenon of the epiphyseal growth retardation and premature closure were very common in the regular plate group. In addition, the sliding plate group exhibited more normal histologic features and Safranin O staining compared to the regular plate group. Our results suggest that the sliding plate can provide reliable internal fixation of epiphyseal fracture without inhibiting epiphyseal growth.

  1. The use of multi-gap resistive plate chambers for in-beam PET in proton and carbon ion therapy

    Science.gov (United States)

    Watts, David; Borghi, Giacomo; Sauli, Fabio; Amaldi, Ugo

    2013-01-01

    On-line verification of the delivered dose during proton and carbon ion radiotherapy is currently a very desirable goal for quality assurance of hadron therapy treatment plans. In-beam positron emission tomography (ibPET), which can provide an image of the β+ activity induced in the patient during irradiation, which in turn is correlated to the range of the ion beam, is one of the modalities for achieving this goal. Application to hadron therapy requires that the scanner geometry be modified from that which is used in nuclear medicine. In particular, PET detectors that allow a sub-nanosecond time-of-flight (TOF) registration of the collinear photons have been proposed. Inclusion of the TOF information in PET data leads to more effective PET sensitivity. Considering the challenges inherent in the ibPET technique, namely limited β+ activity and the effect of biological washout due to blood flow, TOF-PET technologies are very attractive. In this context, the TERA Foundation is investigating the use of resistive plate chambers (RPC) for an ibPET application because of their excellent timing properties and low cost. In this paper we present a novel compact multi-gap RPC (MRPC) module design and construction method, which considering the large number of modules that would be needed to practically implement a high-sensitivity RPC-PET scanner, could be advantageous. Moreover, we give an overview of the efficiency and timing measurements that have been obtained in the laboratory using such single-gap and multi-gap RPC modules. PMID:23824118

  2. The use of multi-gap resistive plate chambers for in-beam PET in proton and carbon ion therapy.

    Science.gov (United States)

    Watts, David; Borghi, Giacomo; Sauli, Fabio; Amaldi, Ugo

    2013-07-01

    On-line verification of the delivered dose during proton and carbon ion radiotherapy is currently a very desirable goal for quality assurance of hadron therapy treatment plans. In-beam positron emission tomography (ibPET), which can provide an image of the β+ activity induced in the patient during irradiation, which in turn is correlated to the range of the ion beam, is one of the modalities for achieving this goal. Application to hadron therapy requires that the scanner geometry be modified from that which is used in nuclear medicine. In particular, PET detectors that allow a sub-nanosecond time-of-flight (TOF) registration of the collinear photons have been proposed. Inclusion of the TOF information in PET data leads to more effective PET sensitivity. Considering the challenges inherent in the ibPET technique, namely limited β+ activity and the effect of biological washout due to blood flow, TOF-PET technologies are very attractive. In this context, the TERA Foundation is investigating the use of resistive plate chambers (RPC) for an ibPET application because of their excellent timing properties and low cost. In this paper we present a novel compact multi-gap RPC (MRPC) module design and construction method, which considering the large number of modules that would be needed to practically implement a high-sensitivity RPC-PET scanner, could be advantageous. Moreover, we give an overview of the efficiency and timing measurements that have been obtained in the laboratory using such single-gap and multi-gap RPC modules.

  3. On the relationship between tectonic plates and thermal mantle plume morphology

    Science.gov (United States)

    Lenardic, A.; Kaula, W. M.

    1993-01-01

    Models incorporating plate-like behavior, i.e., near uniform surface velocity and deformation concentrated at plate boundaries, into a convective system, heated by a mix of internal and basal heating and allowing for temperature dependent viscosity, were constructed and compared to similar models not possessing plate-like behavior. The simplified numerical models are used to explore how plate-like behavior in a convective system can effect the lower boundary layer from which thermal plumes form. A principal conclusion is that plate-like behavior can significantly increase the temperature drop across the lower thermal boundary layer. This temperature drop affects the morphology of plumes by determining the viscosity drop across the boundary layer. Model results suggest that plumes on planets possessing plate-like behavior, e.g., the Earth, may differ in morphologic type from plumes on planets not possessing plate-like behavior, e.g., Venus and Mars.

  4. Regeneration of ciliary comb plates in the ctenophore Mnemiopsis leidyi. i. morphology.

    Science.gov (United States)

    Tamm, Sidney L

    2012-01-01

    Regeneration of missing body parts in model organisms provides information on the mechanisms underlying the regeneration process. The aim here is to use ctenophores to investigate regeneration of their giant ciliary swimming plates. When part of a row of comb plates on Mnemiopsis is excised, the wound closes and heals, greatly increasing the distance between comb plates near the former cut edges. Video differential interference contrast (DIC) microscopy of the regeneration of new comb plates between widely separated plates shows localized widenings of the interplate ciliated groove (ICG) first, followed by growth of two opposing groups of comb plate cilia on either side. The split parts of a new plate elongate as their bases extend laterally away from the ICG widening and continue ciliogenesis at both ends. The split parts of a new plate grow longer and move closer together into the ICG widening until they merge into a single plate that interrupts the ICG in a normal manner. Video DIC snapshots of dissected gap preparations 1.5-3-day postoperation show that ICG widenings and/or new plates do not all appear at the same time or with uniform spacing within a gap: the lengths and distances between young plates in a gap are quite variable. Video stereo microscopy of intact animals 3-4 days after the operation show that all the new plates that will form in a gap are present, fairly evenly spaced and similar in length, but smaller and closer together than normal. Normal development of comb plates in embryos and growing animals is compared to the pattern of comb plate regeneration in adults. Comb plate regeneration differs in the cydippid Pleurobrachia that lacks ICGs and has a firmer mesoglea than Mnemiopsis. This study provides a morphological foundation for histological, cellular, and molecular analysis of ciliary regeneration in ctenophores. Copyright © 2011 Wiley Periodicals, Inc.

  5. Comment on "Intermittent plate tectonics?".

    Science.gov (United States)

    Korenaga, Jun

    2008-06-06

    Silver and Behn (Reports, 4 January 2008, p. 85) proposed that intermittent plate tectonics may resolve a long-standing paradox in Earth's thermal evolution. However, their analysis misses one important term, which subsequently brings their main conclusion into question. In addition, the Phanerozoic eustasy record indicates that the claimed effect of intermittency is probably weak.

  6. License plate recognition using DTCNNs

    NARCIS (Netherlands)

    ter Brugge, M.H; Stevens, J.H; Nijhuis, J.A G; Spaanenburg, L; Tavsanonoglu, V

    1998-01-01

    Automatic license plate recognition requires a series of complex image processing steps. For practical use, the amount of data to he processed must be minimized early on. This paper shows that the computationally most intensive steps can be realized by DTCNNs. Moreover; high-level operations like fi

  7. Corrosion resistant metallic bipolar plate

    Science.gov (United States)

    Brady, Michael P.; Schneibel, Joachim H.; Pint, Bruce A.; Maziasz, Philip J.

    2007-05-01

    A corrosion resistant, electrically conductive component such as a bipolar plate for a PEM fuel cell includes 20 55% Cr, balance base metal such as Ni, Fe, or Co, the component having thereon a substantially external, continuous layer of chromium nitride.

  8. The seismotectonics of plate boundaries

    Science.gov (United States)

    Berger, J.; Brune, J. N.; Goodkind, J.; Wyatt, F.; Agnew, D. C.; Beaumont, C.

    1981-01-01

    Research on the seismotectonics of plate boundaries is summarized. Instrumental development and an observational program designed to study various aspects of the seismotectonics of southern California and the northern Gulf of California are described. A unique superconducting gravimeter was further developed and supported under this program for deployment and operation at several sites. Work on Earth tides is also discussed.

  9. 不同络合剂对化学镀法制备镍包铜复合粉末的影响%Effect of different complexing agents on nickel-coated copper compound powder prepared with chemical plating

    Institute of Scientific and Technical Information of China (English)

    王玉棉; 孙建国; 赵忠兴; 徐瑞

    2013-01-01

    利用化学镀的方法制备镍包铜复合粉末,考察柠檬酸钠、醋酸钠和乳酸3种络合剂对Ni/Cu包覆粉体的转化率、包覆效果及分散性的影响.分别采用扫描电子显微镜、EDS能谱仪、X射线衍射仪对镍包铜粉末的微观形貌和物相组成进行表征.结果表明:采用柠檬酸钠作为络合剂能使镍更好地包覆于铜粉表面,镍金属原子分数大于90%,并且具有良好的分散性.%Using the chemical plating method,the nickel-coated copper composite powder was prepared,and the effect of three complexing agents of sodium citrate,sodium acetate,and lactic acid on the conversion,coating and dispersion of Ni/Cu cladding powder was examined.The microstructure and compositions of nickel-coated copper powder were characterized by means of scanning electron microscope,EDS energy spectrometer and X ray diffractometer respectively.The result showed that,using sodium citrate as complexing agent,the best nickel-coated copper powder could be prepared,and the atomic percentage content of nickel could reach more than 90%,and had good dispersity.

  10. Particle Transport in Parallel-Plate Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Rader, D.J.; Geller, A.S.

    1999-08-01

    A major cause of semiconductor yield degradation is contaminant particles that deposit on wafers while they reside in processing tools during integrated circuit manufacturing. This report presents numerical models for assessing particle transport and deposition in a parallel-plate geometry characteristic of a wide range of single-wafer processing tools: uniform downward flow exiting a perforated-plate showerhead separated by a gap from a circular wafer resting on a parallel susceptor. Particles are assumed to originate either upstream of the showerhead or from a specified position between the plates. The physical mechanisms controlling particle deposition and transport (inertia, diffusion, fluid drag, and external forces) are reviewed, with an emphasis on conditions encountered in semiconductor process tools (i.e., sub-atmospheric pressures and submicron particles). Isothermal flow is assumed, although small temperature differences are allowed to drive particle thermophoresis. Numerical solutions of the flow field are presented which agree with an analytic, creeping-flow expression for Re < 4. Deposition is quantified by use of a particle collection efficiency, which is defined as the fraction of particles in the reactor that deposit on the wafer. Analytic expressions for collection efficiency are presented for the limiting case where external forces control deposition (i.e., neglecting particle diffusion and inertia). Deposition from simultaneous particle diffusion and external forces is analyzed by an Eulerian formulation; for creeping flow and particles released from a planar trap, the analysis yields an analytic, integral expression for particle deposition based on process and particle properties. Deposition from simultaneous particle inertia and external forces is analyzed by a Lagrangian formulation, which can describe inertia-enhanced deposition resulting from particle acceleration in the showerhead. An approximate analytic expression is derived for particle

  11. Structural Analysis of Plate Based Tensegrity Structures

    DEFF Research Database (Denmark)

    Hald, Frederik; Kirkegaard, Poul Henning; Damkilde, Lars

    2013-01-01

    Plate tensegrity structures combine tension cables with a cross laminated timber plate and can then form e.g. a roof structure. The topology of plate tensegrity structures is investigated through a parametric investigation. Plate tensegrity structures are investigated, and a method...... for determination of the structures pre-stresses is used. A parametric investigation is performed to determine a more optimized form of the plate based tensegrity structure. Conclusions of the use of plate based tensegrity in civil engineering and further research areas are discussed....

  12. Structural Analysis of Plate Based Tensegrity Structures

    DEFF Research Database (Denmark)

    Hald, Frederik; Kirkegaard, Poul Henning; Damkilde, Lars

    2013-01-01

    Plate tensegrity structures combine tension cables with a cross laminated timber plate and can then form e.g. a roof structure. The topology of plate tensegrity structures is investigated through a parametric investigation. Plate tensegrity structures are investigated, and a method...... for determination of the structures pre-stresses is used. A parametric investigation is performed to determine a more optimized form of the plate based tensegrity structure. Conclusions of the use of plate based tensegrity in civil engineering and further research areas are discussed....

  13. Avionics Box Cold Plate Damage Prevention

    Science.gov (United States)

    Stambolian, Damon B.; Larchar, Steven W.; Henderson, Gena; Tran, Donald; Barth, Tim

    2012-01-01

    Problem Introduction: 1. Prevent Cold Plate Damage in Space Shuttle. 1a. The number of cold plate problems had increased from an average of 16.5 per/year between 1990 through 2000, to an average of 39.6 per year between 2001through 2005. 1b. Each complete set of 80 cold plates cost approximately $29 million, an average of $362,500 per cold plate. 1c It takes four months to produce a single cold plate. 2. Prevent Cold Plate Damage in Future Space Vehicles.

  14. Topology optimization of laminated plates with prestress

    DEFF Research Database (Denmark)

    Pedersen, Niels Leergaard

    2002-01-01

    Laminated plates with different prestress in the layers are topology optimized. The objectives are to minimize the deflection due to the prestress or to minimize ordinary compliance. The prestress is accounted for by including the force equivalent to the prestressing and adding the initial stress...... stiffness matrix to the structural stiffness. The calculations of sensitivities are complicated not only by the prestress but also because we are dealing with laminates. The topology optimization problem is solved using a new penalization scheme as an alternative to the SIMP (power law) approach...

  15. Efficient transport of droplet sandwiched between saw-tooth plates.

    Science.gov (United States)

    Wang, Liya; Wu, Hengan; Wang, Fengchao

    2016-01-15

    The transport of droplet sandwiched between smooth and saw-tooth plates was investigated using molecular dynamics method. The repeated opening and closing of the plates result in sequential stretching and squeezing of the droplet, which provide the driving force. The asymmetrical saw tooth obstructs the backward motion of the droplet, and gives rise to a net forward displacement of the droplet in every opening and closing cycle. This unidirectional motion facilitates the efficient droplet transport, which is referred to as the ratchet-like effect in this work. Our simulations also reveal that the influence of the surface wettability on the droplet transport is different for saw-tooth and smooth plates. Droplet transport efficiency exhibits monotonic decrease with the increase of the solid-liquid interactions for saw-tooth plates. While for smooth plates, unidirectional droplet movement was only observed for certain solid-liquid interactions. Taken together these simulation results and theoretical analysis, we demonstrate that hydrophobic saw-tooth plates can improve the transport efficiency significantly. These findings not only enhance our understanding of the droplet transport from atomistic scale, but also are beneficial to practical applications in designing of micro- and nano-fluidic systems.

  16. EMPIRICAL STUDY OF CAR LICENSE PLATES RECOGNITION

    Directory of Open Access Journals (Sweden)

    Nasa Zata Dina

    2015-01-01

    Full Text Available The number of vehicles on the road has increased drastically in recent years. The license plate is an identity card for a vehicle. It can map to the owner and further information about vehicle. License plate information is useful to help traffic management systems. For example, traffic management systems can check for vehicles moving at speeds not permitted by law and can also be installed in parking areas to se-cure the entrance or exit way for vehicles. License plate recognition algorithms have been proposed by many researchers. License plate recognition requires license plate detection, segmentation, and charac-ters recognition. The algorithm detects the position of a license plate and extracts the characters. Various license plate recognition algorithms have been implemented, and each algorithm has its strengths and weaknesses. In this research, I implement three algorithms for detecting license plates, three algorithms for segmenting license plates, and two algorithms for recognizing license plate characters. I evaluate each of these algorithms on the same two datasets, one from Greece and one from Thailand. For detecting li-cense plates, the best result is obtained by a Haar cascade algorithm. After the best result of license plate detection is obtained, for the segmentation part a Laplacian based method has the highest accuracy. Last, the license plate recognition experiment shows that a neural network has better accuracy than other algo-rithm. I summarize and analyze the overall performance of each method for comparison.

  17. Dog Bone Triplet Metamaterial Wave Plate

    CERN Document Server

    Mohamed, Imran; Ng, Ming Wah; Haynes, Vic; Maffei, Bruno

    2014-01-01

    Metamaterials are artificially made sub-wavelength structures arranged in periodic arrays. They can be designed to interact with electromagnetic radiation in many different and interesting ways such as allowing radiation to experience a negative refractive index (NRI). We have used this technique to design and build a quasi-optical Half Wave Plate (HWP) that exhibits a large birefringence by virtue of having a positive refractive index in one axis and a NRI in the other. Previous implementations of such NRI-HWP have been narrow band ($\\sim$1-3%) due to the inherent reliance on needing a resonance to create the NRI region. We manufacture a W-band prototype of a novel HWP that uses the Pancharatnam method to extend the bandwidth (up to more than twice) of a usual NRI-HWP. Our simulated and experimentally obtained results despite their differences show that a broadening of a flat region of the phase difference is possible even with the initially steep gradient for a single plate.

  18. Fibroblast growth factor expression in the postnatal growth plate.

    Science.gov (United States)

    Lazarus, Jacob E; Hegde, Anita; Andrade, Anenisia C; Nilsson, Ola; Baron, Jeffrey

    2007-03-01

    analyzed the expression of all known FGFs and FGFRs in the postnatal growth plate using a method that is quantitative and highly sensitive. This approach identified ligands and receptors not previously known to be expressed in growth plate and revealed a complex pattern of spatial regulation of FGFs and FGFRs in the different zones of the growth plate. We also found temporal changes in FGF and FGFR expression which may contribute to growth plate senescence and thus help determine the size of the adult skeleton.

  19. The Optimum Plate to Plate Spacing for Maximum Heat Transfer Rate from a Flat Plate Type Heat Exchanger

    Science.gov (United States)

    Ambarita, Himsar; Kishinami, Koki; Daimaruya, Mashashi; Tokura, Ikuo; Kawai, Hideki; Suzuki, Jun; Kobiyama, Mashayosi; Ginting, Armansyah

    The present paper is a study on the optimum plate to plate spacing for maximum heat transfer rate from a flat plate type heat exchanger. The heat exchanger consists of a number of parallel flat plates. The working fluids are flowed at the same operational conditions, either fixed pressure head or fixed fan power input. Parallel and counter flow directions of the working fluids were considered. While the volume of the heat exchanger is kept constant, plate number was varied. Hence, the spacing between plates as well as heat transfer rate will vary and there exists a maximum heat transfer rate. The objective of this paper is to seek the optimum plate to plate spacing for maximum heat transfer rate. In order to solve the problem, analytical and numerical solutions have been carried out. In the analytical solution, the correlations of the optimum plate to plate spacing as a function of the non-dimensional parameters were developed. Furthermore, the numerical simulation is carried out to evaluate the correlations. The results show that the optimum plate to plate spacing for a counter flow heat exchanger is smaller than parallel flow ones. On the other hand, the maximum heat transfer rate for a counter flow heat exchanger is bigger than parallel flow ones.

  20. The propagation characteristics of the plate modes of acoustic emission waves in thin aluminum plates and thin graphite/epoxy composite plates and tubes. Ph.D. Thesis - Johns Hopkins Univ., 1991

    Science.gov (United States)

    Prosser, William H.

    1991-01-01

    Acoustic emission was interpreted as modes of vibration in plates. Classical plate theory was used to predict dispersion curves for the two fundamental modes and to calculate the shapes of flexural waveforms produced by vertical step function loading. There was good agreement between theoretical and experimental results for aluminum. Composite materials required the use of a higher order plate theory (Reissner-Mindlin) to get good agreement with the measured velocities. Four composite plates with different laminate stacking sequences were studied. The dispersion curves were determined from phase spectra of the time dependent waveforms. Plate modes were shown to be useful for determining the direction of source motion. Aluminum plates were loaded by breaking a pencil lead against their surface. By machining slots at angles to the plane of a plate, the direction in which the force acted was varied. Changing the source motion direction produced regular variations in the waveforms. To demonstrate applicability beyond simple plates, waveforms produced by lead breaks on a thin walled composite tube were also shown to be interpretable as plate modes. The tube design was based on the type of struts proposed for Space Station Freedom's trussed structures.

  1. Measurement procedure for optomechanical hole plate

    DEFF Research Database (Denmark)

    Larsen, Erik

    2003-01-01

    Measurement procedure for optomechanical hole plate in connection with CIRP interlaboratory comparison on measuring machines.......Measurement procedure for optomechanical hole plate in connection with CIRP interlaboratory comparison on measuring machines....

  2. Food Guide Pyramid Becomes a Plate

    Science.gov (United States)

    ... agency in charge of nutrition, created the colorful plate to help people remember to: Eat a variety ... of some foods and more of others. The plate features four sections — vegetables, fruits, grains, and protein — ...

  3. Earth's Decelerating Tectonic Plates

    Energy Technology Data Exchange (ETDEWEB)

    Forte, A M; Moucha, R; Rowley, D B; Quere, S; Mitrovica, J X; Simmons, N A; Grand, S P

    2008-08-22

    Space geodetic and oceanic magnetic anomaly constraints on tectonic plate motions are employed to determine a new global map of present-day rates of change of plate velocities. This map shows that Earth's largest plate, the Pacific, is presently decelerating along with several other plates in the Pacific and Indo-Atlantic hemispheres. These plate decelerations contribute to an overall, globally averaged slowdown in tectonic plate speeds. The map of plate decelerations provides new and unique constraints on the dynamics of time-dependent convection in Earth's mantle. We employ a recently developed convection model constrained by seismic, geodynamic and mineral physics data to show that time-dependent changes in mantle buoyancy forces can explain the deceleration of the major plates in the Pacific and Indo-Atlantic hemispheres.

  4. Earth's Decelerating Tectonic Plates

    Energy Technology Data Exchange (ETDEWEB)

    Forte, A M; Moucha, R; Rowley, D B; Quere, S; Mitrovica, J X; Simmons, N A; Grand, S P

    2008-08-22

    Space geodetic and oceanic magnetic anomaly constraints on tectonic plate motions are employed to determine a new global map of present-day rates of change of plate velocities. This map shows that Earth's largest plate, the Pacific, is presently decelerating along with several other plates in the Pacific and Indo-Atlantic hemispheres. These plate decelerations contribute to an overall, globally averaged slowdown in tectonic plate speeds. The map of plate decelerations provides new and unique constraints on the dynamics of time-dependent convection in Earth's mantle. We employ a recently developed convection model constrained by seismic, geodynamic and mineral physics data to show that time-dependent changes in mantle buoyancy forces can explain the deceleration of the major plates in the Pacific and Indo-Atlantic hemispheres.

  5. Can pterygoid plate asymmetry be linked to temporomandibular joint disorders ?

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero, Maria Eugenia; Jacobs, Reinhilde [OIC, OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, University of Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven (Belgium); Beltran, Jorge [Oral and Maxillofacial Radiology, Post-Graduate School, Universidad Privada Cayetano Heredia, Lima (Peru); Laat, Antoon [Stomatology and Maxillofacial Surgery, Dept. of Oral Health Sciences, KU Leuven, Leuven (Belgium)

    2015-06-15

    This study was performed to evaluate the relationship between pterygoid plate asymmetry and temporomandibular joint disorders. Cone-beam computed tomography (CBCT) images of 60 patients with temporomandibular disorders (TMD) involving pain were analyzed and compared with images of 60 age- and gender-matched controls. Three observers performed linear measurements of the lateral pterygoid plates. Statistically significant differences were found between measurements of the lateral pterygoid plates on the site that had pain and the contralateral site (p<0.05). The average length of the lateral pterygoid plates (LPPs) in patients with TMD was 17.01±3.64 mm on the right side and 16.21±3.51 mm on the left side, and in patients without TMD, it was 11.86±1.97 mm on the right side and 11.98±1.85 mm on the left side. Statistically significant differences in the LPP length, measured on CBCT, were found between patients with and without TMD (p<0.05). The inter-examiner reliability obtained in this study was very high for all the examiners (0.99, 95% confidence interval: 0.98-0.99). Within the limits of the present study, CBCT lateral pterygoid plate measurements at the side with TMD were found to be significantly different from those on the side without TMD. More research is needed to explore potential etiological correlations and implications for treatment.

  6. Embedded adhesive connection for laminated glass plates

    DEFF Research Database (Denmark)

    Hansen, Jens Zangenberg; Poulsen, S.H.; Bagger, A.

    2012-01-01

    The structural behavior of a new connection design, the embedded adhesive connection, used for laminated glass plates is investigated. The connection consists of an aluminum plate encapsulated in-between two adjacent triple layered laminated glass plates. Fastening between glass and aluminum...... usage in a design situation. The embedded connection shows promising potential as a future fastening system for load-carrying laminated glass plates....

  7. Electrochemical Assay of Gold-Plating Solutions

    Science.gov (United States)

    Chiodo, R.

    1982-01-01

    Gold content of plating solution is assayed by simple method that required only ordinary electrochemical laboratory equipment and materials. Technique involves electrodeposition of gold from solution onto electrode, the weight gain of which is measured. Suitable fast assay methods are economically and practically necessary in electronics and decorative-plating industries. If gold content in plating bath is too low, poor plating may result, with consequent economic loss to user.

  8. Modeling the hydrodynamics of Phloem sieve plates

    DEFF Research Database (Denmark)

    Jensen, Kaare Hartvig; Mullendore, Daniel Leroy; Holbrook, Noel Michele;

    2012-01-01

    Sieve plates have an enormous impact on the efficiency of the phloem vascular system of plants, responsible for the distribution of photosynthetic products. These thin plates, which separate neighboring phloem cells, are perforated by a large number of tiny sieve pores and are believed to play...... are investigated. We find that the sieve plate resistance is correlated to the cell lumen resistance, and that the sieve plate and the lumen contribute almost equally to the total hydraulic resistance of the phloem translocation pathway....

  9. Experimental Ultrasound Transmission through Fluid-Solid and Air-Solid Phononic Plates

    Directory of Open Access Journals (Sweden)

    Vicente Gómez-Lozano

    2016-06-01

    Full Text Available Underwater ultrasonic transmissions for fluid-solid and air-solid phononic brass plates are reported in this work. Although the structure is roughly the same, experimental results show very different behaviour between fluid-solid and air-solid phononic plates, due to most of the properties of the fluid-solid perforated plates rely on Fabry-Perot resonances, Wood anomalies and Lamb modes. In air-solid phononic plates Fabry-Perot resonance is highly attenuated due to impedances difference between air and water, and therefore some transmission modes are now distinguishable due to surface modes coupling.

  10. Geothermal Casimir phenomena for the sphere-plate and cylinder-plate configurations

    CERN Document Server

    Weber, Alexej

    2010-01-01

    We investigate the nontrivial interplay between geometry and temperature in the Casimir effect for the sphere-plate and cylinder-plate configurations. At low temperature, the thermal contribution to the Casimir force is dominated by this interplay, implying that standard approximation techniques such as the PFA are inapplicable even in the limit of small surface separation. Thermal fluctuations on scales of the thermal wavelength lead to a delocalization of the thermal force density at low temperatures. As a consequence, the temperature dependence strongly differs from naive expectations. Most prominently, thermal forces can develop non-monotonic behavior below a critical temperature. We perform a comprehensive study of such geothermal phenomena in these Casimir geometries, using analytical and numerical worldline techniques for Dirichlet scalar fluctuations.

  11. Transfinite thin plate spline interpolation

    CERN Document Server

    Bejancu, Aurelian

    2009-01-01

    Duchon's method of thin plate splines defines a polyharmonic interpolant to scattered data values as the minimizer of a certain integral functional. For transfinite interpolation, i.e. interpolation of continuous data prescribed on curves or hypersurfaces, Kounchev has developed the method of polysplines, which are piecewise polyharmonic functions of fixed smoothness across the given hypersurfaces and satisfy some boundary conditions. Recently, Bejancu has introduced boundary conditions of Beppo Levi type to construct a semi-cardinal model for polyspline interpolation to data on an infinite set of parallel hyperplanes. The present paper proves that, for periodic data on a finite set of parallel hyperplanes, the polyspline interpolant satisfying Beppo Levi boundary conditions is in fact a thin plate spline, i.e. it minimizes a Duchon type functional.

  12. Silicon-micromachined microchannel plates

    CERN Document Server

    Beetz, C P; Steinbeck, J; Lemieux, B; Winn, D R

    2000-01-01

    Microchannel plates (MCP) fabricated from standard silicon wafer substrates using a novel silicon micromachining process, together with standard silicon photolithographic process steps, are described. The resulting SiMCP microchannels have dimensions of approx 0.5 to approx 25 mu m, with aspect ratios up to 300, and have the dimensional precision and absence of interstitial defects characteristic of photolithographic processing, compatible with positional matching to silicon electronics readouts. The open channel areal fraction and detection efficiency may exceed 90% on plates up to 300 mm in diameter. The resulting silicon substrates can be converted entirely to amorphous quartz (qMCP). The strip resistance and secondary emission are developed by controlled depositions of thin films, at temperatures up to 1200 deg. C, also compatible with high-temperature brazing, and can be essentially hydrogen, water and radionuclide-free. Novel secondary emitters and cesiated photocathodes can be high-temperature deposite...

  13. Vehicle License Plate Character Segmentation

    Institute of Scientific and Technical Information of China (English)

    Mei-Sen Pan; Jun-Biao Yan; Zheng-Hong Xiao

    2008-01-01

    Vehicle license plate (VLP) character segmentation is an important part of the vehicle license plate recognition system (VLPRS). This paper proposes a least square method (LSM) to treat horizontal tilt and vertical tilt in VLP images. Auxiliary lines are added into the image (or the tilt-corrected image) to make the separated parts of each Chinese character to be an interconnected region. The noise regions will be eliminated after two fusing images are merged according to the minimum principle of gray values.Then, the characters are segmented by projection method (PM) and the final character images are obtained. The experimental results show that this method features fast processing and good performance in segmentation.

  14. Mathematical methods for elastic plates

    CERN Document Server

    Constanda, Christian

    2014-01-01

    Mathematical models of deformation of elastic plates are used by applied mathematicians and engineers in connection with a wide range of practical applications, from microchip production to the construction of skyscrapers and aircraft. This book employs two important analytic techniques to solve the fundamental boundary value problems for the theory of plates with transverse shear deformation, which offers a more complete picture of the physical process of bending than Kirchhoff’s classical one.   The first method transfers the ellipticity of the governing system to the boundary, leading to singular integral equations on the contour of the domain. These equations, established on the basis of the properties of suitable layer potentials, are then solved in spaces of smooth (Hölder continuous and Hölder continuously differentiable) functions.   The second technique rewrites the differential system in terms of complex variables and fully integrates it, expressing the solution as a combination of complex ana...

  15. Electroless metal plating of plastics

    Science.gov (United States)

    Krause, Lawrence J.

    1984-01-01

    Process for plating main group metals on aromatic polymers is carried out by the use of a nonaqueous solution of a salt of an alkali metal in a positive valence state and a main group metal in a negative valence state with contact between the solution and polymer providing a redox reaction causing the deposition of the main group metal and the reduction of the polymer. Products from the process exhibit useful decorative and electrical properties.

  16. High counting rate resistive-plate chamber

    Science.gov (United States)

    Peskov, V.; Anderson, D. F.; Kwan, S.

    1993-05-01

    Parallel-plate avalanche chambers (PPAC) are widely used in physics experiments because they are fast (less than 1 ns) and have very simple construction: just two parallel metallic plates or mesh electrodes. Depending on the applied voltage they may work either in spark mode or avalanche mode. The advantage of the spark mode of operation is a large signal amplitude from the chamber, the disadvantage is that there is a large dead time (msec) for the entire chamber after an event. The main advantage of the avalanche mode is high rate capability 10(exp 5) counts/mm(sup 2). A resistive-plate chamber (RPC) is similar to the PPAC in construction except that one or both of the electrodes are made from high resistivity (greater than 10(exp 10) Omega(cm) materials. In practice RPC's are usually used in the spark mode. Resistive electrodes are charged by sparks, locally reducing the actual electric field in the gap. The size of the charged surface is about 10 mm(sup 2), leaving the rest of the detector unaffected. Therefore, the rate capability of such detectors in the spark mode is considerably higher than conventional spark counters. Among the different glasses tested the best results were obtained with electron type conductive glasses, which obey Ohm's law. Most of the work with such glasses was done with high pressure parallel-plate chambers (10 atm) for time-of-flight measurements. Resistive glasses have been expensive and produced only in small quantities. Now resistive glasses are commercially available, although they are still expensive in small scale production. From the positive experience of different groups working with the resistive glasses, it was decided to review the old idea to use this glass for the RPC. This work has investigated the possibility of using the RPC at 1 atm and in the avalanche mode. This has several advantages: simplicity of construction, high rate capability, low voltage operation, and the ability to work with non-flammable gases.

  17. Evaluation of tin plating systems for a high-noble alloy.

    Science.gov (United States)

    Imbery, T A; Davis, R D

    1993-01-01

    The tensile bond strength of Panavia EX to a high-noble alloy prepared by abrasive spraying and tin plating was measured. Two different intraoperatory tin plating systems were compared. Disk-shaped specimens were cast in type III gold, abrasive sprayed with aluminum oxide, and divided into three groups of 30 specimens each. Specimens in one group were tin plated by using a Kura Ace Mini unit, those in the second group were tin plated by using a Micro Tin unit, and those in the third group were not tin plated and served as the control group. Disks within each group were luted to each other with Panavia EX. The specimens were thermocycled and tested in tension. There was no significant difference between the two tin plated groups; however, the luting bond of both experimental groups was significantly stronger than was that of the control (P < .05).

  18. 49 CFR 236.779 - Plate, top.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Plate, top. 236.779 Section 236.779 Transportation... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.779 Plate, top. A metal plate secured to a locking bracket to prevent the cross locking from being forced out of the...

  19. 30 CFR 22.10 - Approval plate.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approval plate. 22.10 Section 22.10 Mineral... MINING PRODUCTS PORTABLE METHANE DETECTORS § 22.10 Approval plate. (a) Attachment to be made by manufacturers. (1) Manufacturers shall attach, stamp, or mold an approval plate on each permissible methane...

  20. 24 CFR 3280.5 - Data plate.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Data plate. 3280.5 Section 3280.5... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS General § 3280.5 Data plate. Each manufactured home shall bear a data plate affixed in a permanent manner near the main electrical panel or other readily...

  1. 30 CFR 20.13 - Approval plate.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approval plate. 20.13 Section 20.13 Mineral... MINING PRODUCTS ELECTRIC MINE LAMPS OTHER THAN STANDARD CAP LAMPS § 20.13 Approval plate. The manufacturer shall attach, stamp, or mold an approval plate on the battery container or housing of each...

  2. Moving Divertor Plates in a Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    S.J. Zweben, H. Zhang

    2009-02-12

    Moving divertor plates could help solve some of the problems of the tokamak divertor through mechanical ingenuity rather than plasma physics. These plates would be passively heated on each pass through the tokamak and cooled and reprocessed outside the tokamak. There are many design options using varying plate shapes, orientations, motions, coatings, and compositions.

  3. Secure matching of Dutch car license plates

    NARCIS (Netherlands)

    Sunil, A.B.; Erkiny, Z.; Veugenyz, T.

    2016-01-01

    License plate matching plays an important role in applications like law enforcement, traffic management and road pricing, where the plate is first recognized and then compared to a database of authorized vehicle registration plates. Unfortunately, there are several privacy related issues that should

  4. Designing a licence plate for memorability

    NARCIS (Netherlands)

    Schraagen, J.M.C.; Dongen, C.J.G. van

    2005-01-01

    Good memorability of licence plates is important in those cases where licence plates are viewed for a brief period of time and the information is essential for police investigations. The purpose of the current study was to design a new Dutch licence plate that could be remembered well. A memory expe

  5. Probabilistic Assessments of the Plate Using Monte Carlo Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Ismail, A E [Department of Mechanical Engineering, Faculty of Mechanical and Manufacturing Engineering, Universiti Tun Hussein Onn Malaysia, Batu Pahat, 86400 Johor (Malaysia); Ariffin, A K; Abdullah, S; Ghazali, M J, E-mail: kamal@eng.ukm.my, E-mail: shahrum@eng.ukm.my, E-mail: maryam@eng.ukm.my, E-mail: emran@uthm.edu.my [Department of Mechanical and Materials Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor (Malaysia)

    2011-02-15

    This paper presents the probabilistic analysis of the plate with a hole using several multiaxial high cycle fatigue criteria (MHFC). Dang Van, Sines, Crossland criteria were used and von Mises criterion was also considered for comparison purpose. Parametric finite element model of the plate was developed and several important random variable parameters were selected and Latin Hypercube Sampling Monte-Carlo Simulation (LHS-MCS) was used for probabilistic analysis tool. It was found that, different structural reliability and sensitivity factors were obtained using different failure criteria. According to the results multiaxial fatigue criteria are the most significant criteria need to be considered in assessing all the structural behavior especially under complex loadings.

  6. Probabilistic Assessments of the Plate Using Monte Carlo Simulation

    Science.gov (United States)

    Ismail, A. E.; Ariffin, A. K.; Abdullah, S.; Ghazali, M. J.

    2011-02-01

    This paper presents the probabilistic analysis of the plate with a hole using several multiaxial high cycle fatigue criteria (MHFC). Dang Van, Sines, Crossland criteria were used and von Mises criterion was also considered for comparison purpose. Parametric finite element model of the plate was developed and several important random variable parameters were selected and Latin Hypercube Sampling Monte-Carlo Simulation (LHS-MCS) was used for probabilistic analysis tool. It was found that, different structural reliability and sensitivity factors were obtained using different failure criteria. According to the results multiaxial fatigue criteria are the most significant criteria need to be considered in assessing all the structural behavior especially under complex loadings.

  7. Episodic plate tectonics on Venus

    Science.gov (United States)

    Turcotte, Donald

    1992-01-01

    Studies of impact craters on Venus from the Magellan images have placed important constraints on surface volcanism. Some 840 impact craters have been identified with diameters ranging from 2 to 280 km. Correlations of this impact flux with craters on the Moon, Earth, and Mars indicate a mean surface age of 0.5 +/- 0.3 Ga. Another important observation is that 52 percent of the craters are slightly fractured and only 4.5 percent are embayed by lava flows. These observations led researchers to hypothesize that a pervasive resurfacing event occurred about 500 m.y. ago and that relatively little surface volcanism has occurred since. Other researchers have pointed out that a global resurfacing event that ceased about 500 MYBP is consistent with the results given by a recent study. These authors carried out a series of numerical calculations of mantle convection in Venus yielding thermal evolution results. Their model considered crustal recycling and gave rapid planetary cooling. They, in fact, suggested that prior to 500 MYBP plate tectonics was active in Venus and since 500 MYBP the lithosphere has stabilized and only hot-spot volcanism has reached the surface. We propose an alternative hypothesis for the inferred cessation of surface volcanism on Venus. We hypothesize that plate tectonics on Venus is episodic. Periods of rapid plate tectonics result in high rates of subduction that cool the interior resulting in more sluggish mantle convection.

  8. Modified tubularized incised plate urethroplasty

    Directory of Open Access Journals (Sweden)

    Shivaji Mane

    2013-01-01

    Full Text Available Aim: To share our experience of doing tubularized incised plate urethroplasty with modifications. Materials and Methods: This is a single surgeon personal series from 2004 to 2009. One hundred patients of distal hypospadias were subjected for Snodgrass urethroplasty with preputioplasty. The age range was 1 to 5 year with mean age of 2.7 years. Selection criteria were good urethral plate, without chordee and torsion needing complete degloving. Main technical modification from original Snodgrass procedure was spongioplasty, preputioplasty, and dorsal slit when inability to retract prepuce during surgery. Results: Average follow-up period is 23 months. Seven (7% patients developed fistula and one patient had complete preputial dehiscence. Phimosis developed in three (3% patients and required circumcision. Dorsal slit was required in seven patients. One patient developed meatal stenosis in postoperative period. All other patients are passing single urinary stream and have cosmesis that is acceptable. Conclusions: Modified tubularized incised plate urethroplasty with preputioplasty effectively gives cosmetically normal looking penis with low complications.

  9. Trapping of surface gravity waves by a vertical flexible porous plate near a wall

    Science.gov (United States)

    Kaligatla, R. B.; Koley, S.; Sahoo, T.

    2015-10-01

    The present study deals with the trapping of oblique surface gravity waves by a vertical submerged flexible porous plate located near a rigid wall in water of finite as well as infinite depths. The physical problem is based on the assumption of small amplitude water wave theory and structural response. The flexible plate is assumed to be thin and is modeled based on the Euler-Bernoulli beam equation. Using the Green's function technique to the plate equation and associated boundary conditions, an integral equation is derived which relates the normal velocity on the plate to the difference in velocity potentials across the plate involving the porous-effect parameter and structural rigidity. Further, applying Green's second identity to the free-surface Green's function and the scattered velocity potentials on the two sides of the plate, a system of three more integral equations is derived involving the velocity potentials and their normal derivatives across the plate boundary along with the velocity potential on the rigid wall. The system of integral equations is converted into a set of algebraic equations using appropriate Gauss quadrature formula which in turn solved to obtain various quantities of physical interest. Utilizing Green's identity, explicit expressions for the reflection coefficients are derived in terms of the velocity potentials and their normal derivatives across the plate. Energy balance relations are derived and used to check the accuracy of the computational results. As special cases of the submerged plate, wave trapping by the bottom-standing as well as surface-piercing plates is analyzed. Effects of various wave and structural parameters in trapping of surface waves are studied from the computational results by analyzing the reflection coefficients, wave forces exerted on the plate and the rigid wall, flow velocity, plate deflections and surface elevations. It is observed that surface-piercing plate is more effective for trapping of water waves

  10. A Novel Higher-Order Shear and Normal Deformable Plate Theory for the Static, Free Vibration and Buckling Analysis of Functionally Graded Plates

    Directory of Open Access Journals (Sweden)

    Shi-Chao Yi

    2017-01-01

    Full Text Available Closed-form solution of a special higher-order shear and normal deformable plate theory is presented for the static situations, natural frequencies, and buckling responses of simple supported functionally graded materials plates (FGMs. Distinguished from the usual theories, the uniqueness is the differentia of the new plate theory. Each individual FGM plate has special characteristics, such as material properties and length-thickness ratio. These distinctive attributes determine a set of orthogonal polynomials, and then the polynomials can form an exclusive plate theory. Thus, the novel plate theory has two merits: one is the orthogonality, where the majority of the coefficients of the equations derived from Hamilton’s principle are zero; the other is the flexibility, where the order of the plate theory can be arbitrarily set. Numerical examples with different shapes of plates are presented and the achieved results are compared with the reference solutions available in the literature. Several aspects of the model involving relevant parameters, length-to-thickness, stiffness ratios, and so forth affected by static and dynamic situations are elaborate analyzed in detail. As a consequence, the applicability and the effectiveness of the present method for accurately computing deflection, stresses, natural frequencies, and buckling response of various FGM plates are demonstrated.

  11. Anterior cervical discectomy and fusion: analysis of surgical outcome with and without plating.

    Science.gov (United States)

    Mobbs, Ralph J; Rao, Prakash; Chandran, Nadana K

    2007-07-01

    The aim of this study is to analyse the differences in clinical and radiological outcome of anterior cervical discectomy and fusion for cervical degenerative disease, with and without the addition of an anterior cervical locking plate. Although disc arthoplasty is gaining popularity, the anterior cervical decompression and fusion procedure remains the gold standard. The outcome of 242 cases operated between 1991 to 1998 were analysed. Two groups of patients were operated on by the same surgeon. The only difference in technique between the two groups was the addition of an anterior cervical plate, with all other technical details matching, including the use of iliac crest autograft. The indications for surgery for both groups was identical. We made an attempt to study radiological fusion, clinical outcome and complications between the non-plated and plated groups. Our main finding is that the addition of an anterior plate reduces the number of poor clinical outcomes, but does not increase the number of excellent outcomes. Anterior discectomy and fusion with plating in our series had a significantly higher fusion rate; 98% fusion was noted in the plating group as compared to 93.5% in the non-plating group (Fisher's exact test, p=0.029). Union was faster in the plated group with no significant increase in surgical complications. Although clinical outcomes were superior in the plated group for the radiculopathy cohort, excellent outcomes were not significantly higher as compared to the non-plated group. The non-plated group had a significantly higher rate of poor outcomes, with 10% of patients requiring revision surgery for non-union, kyphosis, graft extrusion and graft collapse with foraminal stenosis. 1.8% of the plated group required revision surgery.

  12. Scattering by a perfect electromagnetic conductor (PEMC) plate embedded in lossy medium

    Science.gov (United States)

    Ahmed, Saeed; Khalid Khan, Muhammad; Rehman, Atta Ur

    2016-07-01

    In this article, we develop an analytic theory for a perfect electromagnetic conductor (PEMC) plate embedded in lossy medium. The duality transformation introduced by Lindell and Sihvola is applied to study the electromagnetic wave scattering by a PEMC plate. Perfect electric conductor and perfect magnetic conductor are the limiting cases of PEMC media. Here, we study monoscattering by PEMC plate embedded in four different soil models. Numerical results are discussed and compared with the available literature.

  13. Oscillating layer thickness and vortices generated in oscillation of finite plate

    Science.gov (United States)

    Sin, V. K.; Wong, I. K.

    2016-06-01

    Moving mesh strategy is used in the model of flow induced by oscillating finite plate through software - COMSOL Multiphysics. Flow is assumed to be laminar and arbitrary Lagrangian-Eulerian method is used for moving mesh in the simulation. Oscillating layer thickness is found which is different from the analytical solution by 2 to 3 times depends on the oscillating frequency. Vortices are also observed near the oscillating finite plate because of the edge effect of the finite plate.

  14. Lamb wave scattering by a surface-breaking crack in a plate

    Science.gov (United States)

    Datta, S. K.; Al-Nassar, Y.; Shah, A. H.

    1991-01-01

    An NDE method based on finite-element representation and modal expansion has been developed for solving the scattering of Lamb waves in an elastic plate waveguide. This method is very powerful for handling discontinuities of arbitrary shape, weldments of different orientations, canted cracks, etc. The advantage of the method is that it can be used to study the scattering of Lamb waves in anisotropic elastic plates and in multilayered plates as well.

  15. Scattering of Fexural Gravity Waves by a Two-Dimensional Thin Plate

    Directory of Open Access Journals (Sweden)

    Sudeshna Banerjee

    2017-01-01

    Full Text Available An approximate analysis based on standard perturbation technique together with an application of Green’s integral theorem is used in this paper to study the problem of scattering of water waves by a two dimensional thin plate submerged in deep ocean with ice cover. The reflection and transmission coefficients upto first order are obtained in terms of the shape function describing the plate and are studied graphically for different shapes of the plate.

  16. Development and Clinical Evaluation of MatrixMANDIBLE Subcondylar Plates System (Synthes)

    OpenAIRE

    Cortelazzi, Roberto; Altacera, Mario; Turco, Monica; Antonicelli, Viviana; De Benedittis, Michele

    2014-01-01

    In this article, authors report the different steps of development and clinical validation of MatrixMANDIBLE Subcondylar Plates (Synthes, Soletta, Switzerland), a specialized osteosynthesis system developed by Synthes during the past 4 years. Between 2009 and 2013, a total of 62 patients were treated for subcondylar and condylar neck fractures via a preauricular or retromandibular/transparotid approach. The MatrixMANDIBLE Subcondylar Plates System consists of a Trapezoidal Plate, a three-dime...

  17. Propagation of elastic waves in a plate with rough surfaces

    Institute of Scientific and Technical Information of China (English)

    DAI Shuwu; ZHANG Hailan

    2003-01-01

    The characteristics of Lamb wave propagating in a solid plate with rough surfacesare studied on the basis of small perturbation approximation. The Rayleigh-Lamb frequencyequation expressed with SA matrix is presented. The Rayleigh-Lamb frequency equation fora rough surface plate is different from that for a smooth surface plate, resulting in a smallperturbation Ak on Lamb wave vector k. The imaginary part of Ak gives the attenuationcaused by wave scattering. An experiment is designed to test our theoretical predications.By using wedge-shape pipes, different Lamb wave modes are excited. The signals at differentpositions are received and analyzed to get the dispersion curves and attenuations of differentmodes. The experimental results are compared with the theoretical predications.

  18. Spaceflight and age affect tibial epiphyseal growth plate histomorphometry

    Science.gov (United States)

    Montufar-Solis, Dina; Duke, Pauline J.; Durnova, G.

    1992-01-01

    Growth plate histomorphometry of rats flown aboard the Soviet biosatellite Cosmos 2044, a 14-day spaceflight, was compared with that of control groups. In growth plates of flight animals, there was a significant increase in cell number per column and height of the proliferative zone and a reduction in height and cell number in the hypertrophy/calcification zone. No significant differences were found in matrix organization at the ultrastructural level of flight animals, indicating that although spacefligfht continues to affect bone growth of 15-wk-old rats, extracellular matrix is not altered in the same manner as seen previously in younger animals. All groups showed growth plate characteristics attributed to aging: lack of calcification zone, reduced hypertrophy zone, and unraveling of collagen fibrils. Tail-suspended controls did not differ from other controls in any of the parameters measured. The results suggest that growth plates of older rats are less responsive to unloading by spaceflight or suspension than those of younger rats and provide new evidence about the modifying effect of spaceflight on the growth plate.

  19. Plate tectonics, habitability and life

    Science.gov (United States)

    Spohn, Tilman; Breuer, Doris

    2016-04-01

    The role of plate tectonics in defining habitability of terrestrial planets is being increasingly discussed (e.g., Elkins-Tanton, 2015). Plate tectonics is a significantly evolved concept with a large variety of aspects. In the present context, cycling of material between near surface and mantle reservoirs is most important. But increased heat transport through mixing of cold lithosphere with the deep interior and formation of continental crust may also matter. An alternative mechanism of material cycling between these reservoirs is hot-spot volcanism combined with crust delamination. Hot-spot volcanism will transport volatiles to the atmosphere while delamination will mix crust, possibly altered by sedimentation and chemical reactions, with the mantle. The mechanism works as long as the stagnant lithosphere plate has not grown thicker than the crust and as long as volcanic material is added onto the crust. Thermal evolution studies suggest that the mechanism could work for the first 1-2 Ga of planetary evolution. The efficiency of the mechanism is limited by the ratio of extrusive to intrusive volcanism, which is thought to be less than 0.25. Plate tectonics would certainly have an advantage by working even for more evolved planets. A simple, most-used concept of habitability requires the thermodynamic stability of liquid water on the surface of a planet. Cycling of CO2between the atmosphere, oceans and interior through subduction and surface volcanism is an important element of the carbonate-silicate cycle, a thermostat feedback cycle that will keep the atmosphere from entering into a runaway greenhouse. Calculations for a model Earth lacking plate tectonics but degassing CO2, N, and H2O to form a surface ocean and a secondary atmosphere (Tosi et al, 2016) suggest that liquid water can be maintained on the surface for 4.5Ga. The model planet would then qualify as habitable. It is conceivable that the CO2 buffering capability of its ocean together with silicate

  20. Peridinialean dinoflagellate plate patterns, labels and homologies

    Science.gov (United States)

    Edwards, L.E.

    1990-01-01

    Tabulation patterns for peridinialean dinoflagellate thecae and cysts have been traditionally expressed using a plate labelling system described by C.A. Kofoid in the early 1900's. This system can obscure dinoflagellate plate homologies and has not always been strictly applied. The plate-labelling system presented here introduces new series labels but incorporates key features and ideas from the more recently proposed systems of G.L. Eaton and F.J.R. Taylor, as modified by W.R. Evitt. Plate-series recognition begins with the cingulum (C-series) and proceeds from the cingulum toward the apex for the three series of the epitheca/epicyst and proceeds from the cingulum toward the antapex for the two series of the hypotheca/hypocyst. The epithecal/epicystal model consists of eight plates that touch the anterior margin of the cingulum (E-series: plates E1-E7, ES), seven plates toward the apex that touch the E-series plates (M-series: R, M1-M6), and up to seven plates near the apex that do not touch E-series plates (D-series: Dp-Dv). The hypothecal/hypocystal model consists of eight plates that touch the posterior margin of the cingulum (H-series: H1-H6,HR,HS) and three plates toward the antapex (T1-T3). Epithecal/epicystal tabulation patterns come in both 8- and 7- models, corresponding to eight and seven plates, respectively, in the E-series. Hypothecal/hypocystal tabulation patterns also come in both 8- and 7-models, corresponding to eight and seven plates, respectively, in the H-series. By convention, the 7-model epitheca/epicyst has no plates E1 and M1; the 7-model hypotheca/hypocyst has no plate H6. Within an 8-model or 7-model, the system emphasizes plates that are presumed to be homologous by giving them identical labels. I introduce the adjectives "monothigmate", "dithigmate," and "trithigmate" to designate plates touching one, two, and three plates, respectively, of the adjacent series. The term "thigmation" applies to the analysis of plate contacts between

  1. 钢板和碳纤维布加固不同损伤状态下受弯构件的荷载试验研究%Load Experiment of Flexural Members Reinforced by Steel Plate and Carbon Fiber Sheet in Different Damaged States

    Institute of Scientific and Technical Information of China (English)

    王保定; 薛保贵; 翟科玮

    2014-01-01

    Based on the destructive load experiment of the flexural members by steel plate and carbon fiber sheet in sound state and normal service limit damaged state,the deflection,crack and strain development status and changes of the flexural members reinforced by steel plate and carbon fiber sheet were studied. Comparing the difference of the bending bearing limit capacity,and other indicators with flexural members each other by different way of strengthening in sound state and normal service limit damaged state,evaluating the reinforcement effect comprehensively,the results show as follows. Two kinds of reinforcement measures have significant effect in improving the flexural capacity of the reinforced concrete flexural members in different damaged states. But the effect in sound state is superior to that in damaged state. The effect of the reinforcement by steel plate is superior to that by carbon fiber sheet.%基于钢板加固和碳纤维布加固完好状态下和正常使用极限损伤状态下的受弯构件的破坏荷载试验,研究钢筋混凝土受弯构件在采用粘贴钢板加固和粘贴碳纤维布加固措施后,其挠度、裂缝及应变等的发展变化规律。对比分析完好状态下和正常使用极限损伤状态下采用不同的加固方式,受弯构件极限承载力提高幅度的差异并将受弯构件的其他力学控制指标进行对比分析,综合检验评定其加固效果。试验结果表明:两种加固措施对提高在不同损伤状态下的钢筋混凝土受弯构件的抗弯承载力都具有显著效果,但完好情况下的加固效果优于受损情况,钢板加固措施优于碳纤维布加固。

  2. Development and Clinical Evaluation of MatrixMANDIBLE Subcondylar Plates System (Synthes).

    Science.gov (United States)

    Cortelazzi, Roberto; Altacera, Mario; Turco, Monica; Antonicelli, Viviana; De Benedittis, Michele

    2015-06-01

    In this article, authors report the different steps of development and clinical validation of MatrixMANDIBLE Subcondylar Plates (Synthes, Soletta, Switzerland), a specialized osteosynthesis system developed by Synthes during the past 4 years. Between 2009 and 2013, a total of 62 patients were treated for subcondylar and condylar neck fractures via a preauricular or retromandibular/transparotid approach. The MatrixMANDIBLE Subcondylar Plates System consists of a Trapezoidal Plate, a three-dimensional (3D) 4-hole 1.0-mm plate for smaller fracture areas, the Lambda Plate, a 7-hole 1.0-mm linear plate which mimics the two miniplates technique, and the Strut Plate, a 3D 1.0-mm plate with great versatility of employment. All devices satisfy the principles of a functionally stable osteosynthesis as stated by Champy et al. None of the plates broke and no macroscopic condylar displacement was noted on radiological follow-up. Clinical and functional parameters assessed at 6 months postoperative (mandibular range of motion, pain, dental occlusion) were almost restored. MatrixMANDIBLE Subcondylar Plates System (Synthes) has proved to provide sufficient mechanical stiffness and anatomically accurate fracture reduction to avoid major postoperative drawbacks of subcondylar and condylar neck fractures.

  3. Evaluation of Thin Plate Hydrodynamic Stability through a Combined Numerical Modeling and Experimental Effort

    Energy Technology Data Exchange (ETDEWEB)

    Tentner, A. [Argonne National Lab. (ANL), Argonne, IL (United States); Bojanowski, C. [Argonne National Lab. (ANL), Argonne, IL (United States); Feldman, E. [Argonne National Lab. (ANL), Argonne, IL (United States); Wilson, E. [Argonne National Lab. (ANL), Argonne, IL (United States); Solbrekken, G [Univ. of Missouri, Columbia, MO (United States); Jesse, C. [Univ. of Missouri, Columbia, MO (United States); Kennedy, J. [Univ. of Missouri, Columbia, MO (United States); Rivers, J. [Univ. of Missouri, Columbia, MO (United States); Schnieders, G. [Univ. of Missouri, Columbia, MO (United States)

    2017-05-01

    An experimental and computational effort was undertaken in order to evaluate the capability of the fluid-structure interaction (FSI) simulation tools to describe the deflection of a Missouri University Research Reactor (MURR) fuel element plate redesigned for conversion to lowenriched uranium (LEU) fuel due to hydrodynamic forces. Experiments involving both flat plates and curved plates were conducted in a water flow test loop located at the University of Missouri (MU), at conditions and geometries that can be related to the MURR LEU fuel element. A wider channel gap on one side of the test plate, and a narrower on the other represent the differences that could be encountered in a MURR element due to allowed fabrication variability. The difference in the channel gaps leads to a pressure differential across the plate, leading to plate deflection. The induced plate deflection the pressure difference induces in the plate was measured at specified locations using a laser measurement technique. High fidelity 3-D simulations of the experiments were performed at MU using the computational fluid dynamics code STAR-CCM+ coupled with the structural mechanics code ABAQUS. Independent simulations of the experiments were performed at Argonne National Laboratory (ANL) using the STAR-CCM+ code and its built-in structural mechanics solver. The simulation results obtained at MU and ANL were compared with the corresponding measured plate deflections.

  4. A new dual-plate slipometer for measuring slip between molten polymers and extrusion die materials.

    Science.gov (United States)

    Schmalzer, A M; Giacomin, A J

    2014-04-01

    In this work, we study the slip behaviors common to plastics die extrusion metals or platings using a new instrument called a dual-plate slipometer. By dual-plate, we mean that whereas the stationary plate incorporates a local shear stress transducer, the moving plate does not. The stationary plate and transducer are made of one stainless steel, but the moving plate is made from, or plated with, different extrusion die materials under study. This new instrument allows slip velocity to be measured without having to build a new shear stress transducer from each extrusion metal or plating under study. We explore the effect of extrusion die composition and die metal surface morphology on the slip properties of polyolefins using a sliding plate rheometer. In this work, we studied the slip behaviors of polyolefins on four common plastics die extrusion metals or platings, without having to build a new shear stress transducer from each. Specifically, our new method replaces the moving plate; with each of the four die metals or platings under study without changing the stainless steel material of the shear stress transducer and its stationary plate. Our experiments include high-density polyethylene, low-density polyethylene, and polypropylene (PP) on four different die metals or platings. We use steady simple shear to obtain shear stress versus nominal shear rate for different gaps, from which we can then deduce the slip velocity using the Mooney analysis. We then fit four slip models to our experimental measurements, and we find the Hatzikiriakos hyperbolic sine model to be accurate, even for the measured inflections in the slip velocity as a function of shear stress curves. Our analysis includes detailed characterization of the die metal plating surfaces, including measurements of the composition of the sliding plates by energy dispersive spectroscopy, surface energy by contact angle goniometry, and surface roughness by both white light interference and stylus

  5. Influence of the Print Run on Silver Halide Printing Plates

    Directory of Open Access Journals (Sweden)

    Tomislav Cigula

    2010-09-01

    Full Text Available The most common printing technique today is lithography. The difference between printing and nonprinting areason a printing plate is accomplished by opposite physical and chemical properties of those areas (MacPhee, 1998.The printing areas are made of photoactive layer that attracts oil and chemical substances with oil solvent – printinginks. The nonprinting areas are made of aluminium-oxide which attracts water based substances – the fountainsolution.There are many of various types of photoactive layer which are used for production of offset printing plates, amongothers is silver halide layer. The usage of the silver halide technology in the graphic reproduction is not a novelty.The filmmaking phase is based on the usage of the silver halide as the photographically active ingredient, for instance,AgBr (silver bromide. The new, digital plate making technology (Computer to Plate, CtP eliminates thefilmmaking phase and therefore enables control of the printing plate’s exposure made by computer. CtP technologyeliminates the filmmaking phase, but it also results with the reduction of needed material quantities and requiredtime for the production (Limburg, 1994; Seydel, 1996.In this paper the basis of the graphic reproduction by using the silver halide digital printing plates was described.The changes of the AgX copying layer and the surface of the aluminium base in the printing process have beenobserved. The surface characteristics were determined by measuring the relevant surface roughness parameters. Inaddition, measurements of coverage values on the prints, detailed at smaller print run, were conducted.Results showed that surface changes on the printing plate are changing during printing process and that thesechanges influence transfer of the printing ink on the printing substrate. These measurements proved to be of greatinterest in the graphic reproduction as they enable us to determine consistency of the printing plates during theprinting

  6. Levator plate upward lift and levator muscle strength

    Science.gov (United States)

    Rostaminia, Ghazaleh; Peck, Jennifer; Quiroz, Lieschen; Shobeiri, S. Abbas

    2016-01-01

    Objective The aim of study was to compare digital palpation with the levator plate lift measured by endovaginal and transperineal dynamic ultrasound. Methods Dynamic transperineal and endovaginal ultrasound were performed as part of multicompartmental pelvic floor functional assessment. Patients were instructed to perform Kegels while a probe captured the video clip of the levator plate movement at rest and during contraction in 2D mid-sagittal posterior view. We measured the distance between the levator plate and the probe on endovaginal ultrasound as well as the distance between the levator plate and the gothic arch of the pubis in transperineal ultrasound. The change in diameter (lift) and a levator plate lift ratio (lift / rest) x 100) were calculated. Pelvic floor muscle strength was assessed by digital palpation and divided into functional and non-functional groups using the Modified Oxford Scale (MOS). Mean differences in levator plate upward lifts were compared by MOS score using student t-tests and analysis of variance (ANOVA). Results 74 women were available for analysis. The mean age was 55 (SD±11.9). When measured by vaginal dynamic ultrasound, mean values of the lift and lift/rest ratio increased with increasing MOS score (ANOVA p=0.09 and p=0.04, respectively). When MOS scores were categorized to represent non-functional (MOS 0-1) and functional (MOS 2-5) muscle strength groups, the mean values of the lift (3.2 mm vs. 4.6 mm, p=0.03) and lift/rest ratio (13% vs 20%, p=0.01) were significantly higher in women with functional muscle strength. All patients with ≥ 30% lift detected by vaginal ultrasound had functional muscle strength. Conclusions Greater levator plate lift ratio detected by dynamic endovaginal ultrasound was associated with higher muscle strength as determined by MOS. This novel measurement can be incorporated into ultrasound evaluation of the levator ani function. PMID:26333568

  7. Capacity of the circular plate condenser: analytical solutions for large gaps between the plates

    Science.gov (United States)

    Rao, T. V.

    2005-11-01

    A solution of Love's integral equation (Love E R 1949 Q. J. Mech. Appl. Math. 2 428), which forms the basis for the analysis of the electrostatic field due to two equal circular co-axial parallel conducting plates, is considered for the case when the ratio, τ, of distance of separation to radius of the plates is greater than 2. The kernel of the integral equation is expanded into an infinite series in odd powers of 1/τ and an approximate kernel accurate to {\\cal O}(\\tau^{-(2N+1)}) is deduced therefrom by terminating the series after an arbitrary but finite number of terms, N. The approximate kernel is rearranged into a degenerate form and the integral equation with this kernel is reduced to a system of N linear equations. An explicit analytical solution is obtained for N = 4 and the resulting analytical expression for the capacity of the circular plate condenser is shown to be accurate to {\\cal O}(\\tau^{-9}) . Analytical expressions of lower orders of accuracy with respect to 1/τ are deduced from the four-term (i.e., N = 4) solution and predictions (of capacity) from the expressions of different orders of accuracy (with respect to 1/τ) are compared with very accurate numerical solutions obtained by solving the linear system for large enough N. It is shown that the {\\cal O}(\\tau^{-9}) approximation predicts the capacity extremely well for any τ >= 2 and an {\\cal O}(\\tau^{-3}) approximation gives, for all practical purposes, results of adequate accuracy for τ >= 4. It is further shown that an approximate solution, applicable for the case of large distances of separation between the plates, due to Sneddon (Sneddon I N 1966 Mixed Boundary Value Problems in Potential Theory (Amsterdam: North-Holland) pp 230-46) is accurate to {\\cal O}(\\tau^{-6}) for τ >= 2.

  8. Electroless plating of rhenium-nickel alloys

    Energy Technology Data Exchange (ETDEWEB)

    Duhin, Alla [Biomaterials and Corrosion Laboratory, School of Mechanical Engineering and The Materials and Nanotechnologies Program, Tel-Aviv University, Ramat-Aviv, Tel Aviv 69978 (Israel); Inberg, Alexandra [Department of Physical Electronics, Faculty of Engineering, Tel-Aviv University, Ramat-Aviv, Tel Aviv 69978 (Israel); Eliaz, Noam, E-mail: neliaz@eng.tau.ac.il [Biomaterials and Corrosion Laboratory, School of Mechanical Engineering and The Materials and Nanotechnologies Program, Tel-Aviv University, Ramat-Aviv, Tel Aviv 69978 (Israel); Gileadi, Eliezer [School of Chemistry, Faculty of Exact Sciences, Tel-Aviv University, Ramat-Aviv, Tel Aviv 69978 (Israel)

    2011-11-01

    In this study, rhenium-nickel (Re-Ni) films were formed by electroless deposition on conductive (Cu) and non-conductive (SiO{sub 2}) substrates. Different bath compositions were evaluated, aiming to achieve high Re-content. Both sodium hypophosphite and dimethylamine-borane were used as reducing agents. Films containing up to 75 at% Re were obtained. The influence of nickel concentration in the solution on alloy composition, deposition rate and surface morphology were determined. It is shown that Ni{sup 2+} acts as a catalyst for the in situ reduction of the perrhenate ion, in a manner similar to what was proposed for electroplating of the same alloy. The rate of electroless plating is similar to that found in electroplating at an applied current density of 50 mA cm{sup -2}. While pure Re cannot be deposited from our electroless plating baths, the addition of even a very small amount of Ni{sup 2+} ions (0.25 mM) is enough to start the induced codeposition of Re. Proper selection of the bath composition can lead to fine control of the alloy thickness and its Re-content, thus making it potentially attractive for thin barrier layers.

  9. Heat Distribution Mathematical Model and Numerical Simulation of Plates of Different Shapes Heated in Electric Oven%不同形状盘子在电烤箱中加热后的热量分布数学模型及数值模拟

    Institute of Scientific and Technical Information of China (English)

    赵建强; 孙运楼; 秦佳敏; 胡继宝

    2013-01-01

    通过建立三维热传导方程模型,研究不同正多边形形状的金属盘子在电烤箱中加热后的热量分布情况,用有限容积法进行求解,并对其进行数值模拟,以指导其在食品烘烤方面的应用。%A three-dimensional heat conduction equation model is established to research on heat distribution of different shapes plate heated in an electric oven in this paper. The mathematical model is solved by using the finite volume method, and numerical simulation is taken to guide food baking.

  10. Discrete Simulation of Flexible Plate Structure Using State-Space Formulation

    Institute of Scientific and Technical Information of China (English)

    S. Md. Salleh; M. O. Tokhi

    2008-01-01

    This paper presents the development of dynamic simulation of a flexible plate structure with various boundary conditions. A flexible square plate is considered. A finite-difference method is used to discretise the governing partial differential equation formulation describing its dynamic behaviour. The model thus developed has been validated against characteristic parameters of the plate. The model thus developed is further formulated using discrete state-space representation, to allow easy and fast implementation for simulating the dynamic behaviour of the plate with various boundary conditions. The simulation algorithm thus developed is validated, and accurate results with representation of the first five modes of vibration of the plate have been achieved. The algorithm thus developed is used in subsequent research work as a platform for development and verification of suitable control strategies for vibration suppression of flexible plate structures.

  11. Alkali ion migration between stacked glass plates by corona discharge treatment

    Science.gov (United States)

    Kawaguchi, Keiga; Suzuki, Toshio; Ikeda, Hiroshi; Sakai, Daisuke; Funatsu, Shiro; Uraji, Keiichiro; Yamamoto, Kiyoshi; Harada, Kenji; Nishii, Junji

    2015-05-01

    Corona discharge reflects the spatial migration of alkali ions over a gap between two glass plates. This study examined stacked glass plates containing different alkali ions treated with the corona discharge plasma generated by applied voltage of 4.5 kV at 200 °C. Protons generated at the anode electrode penetrate into the potassium-ion-containing upper glass plate, which is located 5 mm below the anode electrode. Potassium ions intruded into the lower glass plate containing sodium ions placed on the cathode electrode, even over a 1 mm gap separating the plates. Finally, the sodium ion discharged on the cathode electrode. The hydrogen atmosphere was effective at inhibiting the potassium ion reaction with ambient gases during the spatial migration between the two glass plates.

  12. Flexural-torsional buckling analysis of angle-bar stiffened plates

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Rahbar Ranji [Amirkabir University of Technology, Tehran (Iran, Islamic Republic of)

    2015-09-15

    The interaction of flexural-torsional buckling modes is critical for stiffened plates with asymmetric stiffeners. However, this interaction is ignored in all design rules because it is complex to characterize. In the literature, the presence of an attached plate is ignored, and stiffened plate is treated as an ordinary asymmetric beam. In the flexural buckling mode, stiffener and the attached plate buckle together; in the torsional buckling mode, the attached plate cannot freely rotate with stiffener. Basic equations of the flexural-torsional buckling modes are deduced based on hybrid beam concept and a new strain distribution assumption for sideway bending of stiffeners. Elastic buckling stresses of different angle-bar stiffened plates are calculated and compared with those generated by the Finite element method (FEM) and those available in the literature. The present method has better agreements with FEM.

  13. Measurement of thickness profiles of glass plates by analyzing Haidinger fringes.

    Science.gov (United States)

    Park, Ju Eun; Kim, Jiung; Cha, Myoungsik

    2017-03-01

    We report what we believe is a novel method for measuring the thickness profiles of plane parallel plates by analyzing their Haidinger fringes. When an extended monochromatic source is viewed through a ∼1-mm-thick plate, concentric transmission-type Haidinger fringes can easily be observed. Small variations in the plate thickness result in changes in the radii of the ring fringes. In this study, we scanned 20-mm-diameter fused silica and BK7 plates while tracing a specific ring in each fringe pattern to measure the thickness profiles of the plates, achieving an uncertainty of 2 nm in the measurements of the thickness differences between two locations on each plate.

  14. When Did Plate Tectonics Begin

    Science.gov (United States)

    Brown, M.

    2015-12-01

    Present-day plate tectonics on Earth is characterized by asymmetric (one-sided) subduction, but how do we recognize the imprint of subduction in the geologic record? How do we weigh global (commonly younger) vs local (commonly older) datasets or distinguish initiation from episodic from continuous subduction? How reliable are data gaps? Characteristics of the Paleozoic record of subduction include calc-alkaline magmatism, blueschist/UHP metamorphism and collisional orogenesis, and ophiolites as representatives of former ocean lithosphere. Are these characteristic rocks preserved in Proterozoic, Archean and Hadean crust? Does a hotter mantle, higher heat production and weaker lithosphere modify or eliminate these features? What preceded subduction and how do we recognize that regime? Are rock associations or geochemical fingerprints reliable? Does reworking and overprinting modify geochemical fingerprints? Proposals for the start of plate tectonics have been based on: persistence of isotope anomalies/fractionated chemical domains in the mantle; changes in chemistry of magmatic rocks, rates of crustal growth vs reworking, and sites of growth; the metamorphic record, particularly the first appearance of contrasting thermal gradients or eclogite (including evidence from mineral inclusions in diamonds) or UHP metamorphic rocks; stabilization of cratonic lithosphere and formation of supercratons, and the beginning of the Proterozoic supercontinent cycle; the end of the flat Earth, emergence of continents, development of significant topography, changes in the style of orogeny and the rise in atmospheric oxygen; and, the appearance of passive margins and changes in the style of sedimentation. Estimates of the timing have varied from the Hadean to Neoproterozoic. I will summarize evidence for a growing consensus that the late Mesoarchean to early Paleoproterozoic was a 700 Myr long period of transition to continuous (?) subduction and global (?) mobile-lid plate tectonics.

  15. Draft effect on wave action with a semi-infinite elastic plate

    Institute of Scientific and Technical Information of China (English)

    TENG Bin; GOU Ying; CHENG Liang; LIU Shuxue

    2006-01-01

    A method for analyzing reflection and transmission of ocean waves from a semi-infinite elastic plate with a draft is developed. The relation of energy conservation for plates with three different edge conditions (free, simply supported and built-in) is also derived. It is found that the present method satisfies the energy relation very well. The effects of draft on wave reflection and transmission coefficients as well as on the vertical vibration of the plates are examined through numerical tests. It is demonstrated that the zero draft assumption works well for low wave frequencies, but the effect of plate draft becomes significant for high wave frequencies.

  16. Ballistic Behaviour of Thick Steel Armour Plate under Oblique Impact : Experimental Investigation II

    OpenAIRE

    S. N. Dikshit

    1999-01-01

    The ballistic behaviour of thick steel armour plate at different obliquities has been investigated. Ballistic experiments were conducted in the velocity range 300-800 mls at 0°, 15°, 30° and 45° obliquity .A steel, conical projectile or 6.1 mm diameter was impacted on a 10 mm thick steel armour plate. At 30° and 45° obliquity, the plate offers protection up to a striking velocity of 800 mls. At zero obliquity, the plate provides protection below 6~ m/s. The depth of penetration decreases with...

  17. Ballistic Behaviour of Thick Steel Armour Plate under Oblique Impact: Experimental Investigation .

    OpenAIRE

    S. N. Dikshit

    1998-01-01

    The ballistic behaviour of thick steel amlOW- plate has been investigated at different obliquity when impacted by an ogive-shaped steel projectile. The ballistic experiments have been conducted in the velocity range 300-800 m/s. Both the thickness of the target plate and the diameter of the projectile were 20 Inm. At 30 and 45. obliquity 20 mm plate provides full protection at 800 m/s, whereas at 0 and 15. obliquity, the plate provides protection up to 600 m/s. At 15 and 30° obliquity, the pl...

  18. Ballistic Behaviour of Thick Steel Armour Plate under Oblique Impact : Experimental Investigation II

    OpenAIRE

    S. N. Dikshit

    1999-01-01

    The ballistic behaviour of thick steel armour plate at different obliquities has been investigated. Ballistic experiments were conducted in the velocity range 300-800 mls at 0°, 15°, 30° and 45° obliquity .A steel, conical projectile or 6.1 mm diameter was impacted on a 10 mm thick steel armour plate. At 30° and 45° obliquity, the plate offers protection up to a striking velocity of 800 mls. At zero obliquity, the plate provides protection below 6~ m/s. The depth of penetration decreases with...

  19. Ballistic Behaviour of Thick Steel Armour Plate under Oblique Impact: Experimental Investigation .

    OpenAIRE

    S. N. Dikshit

    1998-01-01

    The ballistic behaviour of thick steel amlOW- plate has been investigated at different obliquity when impacted by an ogive-shaped steel projectile. The ballistic experiments have been conducted in the velocity range 300-800 m/s. Both the thickness of the target plate and the diameter of the projectile were 20 Inm. At 30 and 45. obliquity 20 mm plate provides full protection at 800 m/s, whereas at 0 and 15. obliquity, the plate provides protection up to 600 m/s. At 15 and 30° obliquity, the pl...

  20. Analysis of interlaminar stress and nonlinear dynamic response for composite laminated plates with interfacial damage

    Science.gov (United States)

    Zhu, F. H.; Fu, Y. M.

    2008-12-01

    By considering the effect of interfacial damage and using the variation principle, three-dimensional nonlinear dynamic governing equations of the laminated plates with interfacial damage are derived based on the general six-degrees-of-freedom plate theory towards the accurate stress analysis. The solutions of interlaminar stress and nonlinear dynamic response for a simply supported laminated plate with interfacial damage are obtained by using the finite difference method, and the results are validated by comparison with the solution of nonlinear finite element method. In numerical calculations, the effects of interfacial damage on the stress in the interface and the nonlinear dynamic response of laminated plates are discussed.