WorldWideScience

Sample records for plate radiant energy

  1. Radiant energy to electric energy converter

    Science.gov (United States)

    Sher, Arden (Inventor)

    1980-01-01

    Radiant energy is converted into electric energy by irradiating a capacitor including an ionic dielectric. The dielectric is a sintered crystal superionic conductor, e.g., lanthanum trifluoride, lanthanum trichloride, or silver bromide, so that a multiplicity of crystallites exist between electrodes of the capacitor. The radiant energy cyclically irradiates the dielectric so that the dielectric exhibits a cyclic photocapacitive like effect. Adjacent crystallites have abutting surfaces that enable the crystallites to effectively form a multiplicity of series capacitor elements between the electrodes. Each of the capacitor elements has a dipole layer only on or near its surface. The capacitor is initially charged to a voltage just below the dielectric breakdown voltage by connecting it across a DC source causing a current to flow through a charging resistor to the dielectric. The device can be utilized as a radiant energy detector or as a solar energy cell.

  2. Radiant heat for energy conservation

    Energy Technology Data Exchange (ETDEWEB)

    Pound, R.V.

    1980-05-02

    It is proposed that human comfort could be provided in otherwise chilly surroundings by filling the occupied space with electromagnetic energy of centimeter wavelength. Very considerable reductions in the consumption of energy required for the heating of buildings should result from the lowering of interior temperatures thereby permitted.

  3. Radiant Energy Power Source for Jet Aircraft

    Energy Technology Data Exchange (ETDEWEB)

    Doellner, O.L.

    1992-02-01

    This report beings with a historical overview on the origin and early beginnings of Radiant Energy Power Source for Jet Aircraft. The report reviews the work done in Phase I (Grant DE-FG01-82CE-15144) and then gives a discussion of Phase II (Grant DE-FG01-86CE-15301). Included is a reasonably detailed discussion of photovoltaic cells and the research and development needed in this area. The report closes with a historical perspective and summary related to situations historically encountered on projects of this nature. 15 refs.

  4. Clouds and the Earth's Radiant Energy System (CERES)

    Data.gov (United States)

    National Aeronautics and Space Administration — The Clouds and the Earth's Radiant Energy System (CERES) is a key component of the Earth Observing System (EOS) program. The CERES instruments provide radiometric...

  5. Design of energy efficient building with radiant slab cooling

    Science.gov (United States)

    Tian, Zhen

    2007-12-01

    Air-conditioning comprises a substantial fraction of commercial building energy use because of compressor-driven refrigeration and fan-driven air circulation. Core regions of large buildings require year-round cooling due to heat gains from people, lights and equipment. Negative environmental impacts include CO2 emissions from electric generation and leakage of ozone-depleting refrigerants. Some argue that radiant cooling simultaneously improves building efficiency and occupant thermal comfort, and that current thermal comfort models fail to reflect occupant experience with radiant thermal control systems. There is little field evidence to test these claims. The University of Calgary's Information and Communications Technology (ICT) Building, is a pioneering radiant slab cooling installation in North America. Thermal comfort and energy performance were evaluated. Measurements included: (1) heating and cooling energy use, (2) electrical energy use for lighting and equipment, and (3) indoor temperatures. Accuracy of a whole building energy simulation model was evaluated with these data. Simulation was then used to compare the radiant slab design with a conventional (variable air volume) system. The radiant system energy performance was found to be poorer mainly due to: (1) simultaneous cooling by the slab and heating by other systems, (2) omission of low-exergy (e.g., groundwater) cooling possible with the high cooling water temperatures possible with radiant slabs and (3) excessive solar gain and conductive heat loss due to the wall and fenestration design. Occupant thermal comfort was evaluated through questionnaires and concurrent measurement of workstation comfort parameters. Analysis of 116 sets of data from 82 occupants showed that occupant assessment was consistent with estimates based on current thermal comfort models. The main thermal comfort improvements were reductions in (1) local discomfort from draft and (2) vertical air temperature stratification. The

  6. Radiant energy dosimeter for field use

    Science.gov (United States)

    A. Broido; A.W. McMasters

    1967-01-01

    Thermal radiation measurements in Project Flambeau fires involved a limited number of conventional radiometers located outside the fire periphery. A simple, cheap, easily-fabricated, light-weight, self-contained, rugged dosimeter was desired to withstand a hot fire environment, including a specific energy input of 5,000 cal cm -2, and to record...

  7. Radiant Energy Power Source for Jet Aircraft. Final performance report

    Energy Technology Data Exchange (ETDEWEB)

    Doellner, O.L.

    1992-02-01

    This report beings with a historical overview on the origin and early beginnings of Radiant Energy Power Source for Jet Aircraft. The report reviews the work done in Phase I (Grant DE-FG01-82CE-15144) and then gives a discussion of Phase II (Grant DE-FG01-86CE-15301). Included is a reasonably detailed discussion of photovoltaic cells and the research and development needed in this area. The report closes with a historical perspective and summary related to situations historically encountered on projects of this nature. 15 refs.

  8. Energy, cost, and CO 2 emission comparison between radiant wall panel systems and radiator systems

    CERN Document Server

    Bojić, Milorad; Miletić, Marko; Malešević, Jovan; Boyer, Harry

    2012-01-01

    The main goal of this paper is to evaluate the possibility of application or replacement of radiators with low-temperature radiant panels. This paper shows the comparison results of operations of 4 space heating systems: the low-temperature radiant panel system without any additional thermal insulation of external walls (PH-WOI), the low-temperature radiant panel system with additional thermal insulation of external walls (PH-WI), the radiator system without any additional thermal insulation of external walls (the classical heating system) (RH-WOI), and the radiator system with additional thermal insulation of external walls (RH-WI). The operation of each system is simulated by software EnergyPlus. The investigation shows that the PH-WI gives the best results. The RH-WOI has the largest energy consumption, and the largest pollutant emission. However, the PH-WI requires the highest investment.

  9. 16 CFR Figure 8 to Subpart A of... - Standard Radiant Heat Energy Flux Profile

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Standard Radiant Heat Energy Flux Profile 8 Figure 8 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS INTERIM SAFETY STANDARD FOR CELLULOSE INSULATION The Standard Pt. 1209...

  10. Atmospheric radiative flux divergence from Clouds and Earth Radiant Energy System (CERES)

    Science.gov (United States)

    Smith, Louis G.; Charlock, Thomas P.; Crommelynk, D.; Rutan, David; Gupta, Shashi

    1990-01-01

    A major objective of the Clouds and Earth Radiant Energy System (CERES) is the computation of vertical profiles through the atmosphere of the divergence of radiation flux, with global coverage. This paper discusses the need for radiation divergence and presents some options for its inference from CERES measurements and other data from the Earth Observating System.

  11. Numerical investigation of the single scattering albedo of radiant energy passing through polydisperse crystalline media

    Science.gov (United States)

    Shefer, O. V.; Shefer, V. A.; Sinyukova, E. A.

    2014-12-01

    Studies of the role of atmospheric formations and cosmic dust clouds in the transmission of radiation is one of the most uncertain and difficult problems in astrophysics and climatology. One of the main tasks of practical astrophysics is the interpretation of the results of observations of space objects. There is a necessity of describing the propagation of electromagnetic waves in the environment. In this paper, applying the numerical methods, we study the optical characteristics of polydisperse media consisting of randomly oriented and preferentially oriented crystals, taking into account the distribution function of particle sizes. Particles of spherical shape and ensembles preferentially oriented plate crystals are considered as models. Mie theory and method of physical optics are used to calculate the scattering characteristics. Numerical study of the effects of extinction, scattering and absorption on the single scattering albedo of radiation allowed us to establish the basic patterns of the passage of radiant energy through a translucent medium. At the visible range of wavelengths, both for small and large particles, the single scattering albedo is almost equal to 1. The spectral course of this optical performance is mainly determined by the refractive index of the particles. Features of wave dependence of single scattering albedo are associated with microphysical parameters of the environment, which are more pronounced when the attenuation of the radiation is determined mainly by the scattering. Higher values of the absorption index and optical thickness of the crystal reduce the value of the single scattering albedo, smoothing the features of its spectral course. Values of the absorption index of substance, as value of the order of 0.1, do not lead to a decrease of the single scattering albedo as it is less than 0.5. This allows us to conclude that we should not neglect the microphysical characteristics of the crystals even by strong absorption of radiant

  12. Molecules, Water, and Radiant Energy: New Clues for the Origin of Life

    OpenAIRE

    Qing Zhao; Gerald H. Pollack; Xavier Figueroa

    2009-01-01

    We here examine the putative first step in the origin of life: the coalescence of dispersed molecules into a more condensed, organized state. Fresh evidence implies that the driving energy for this coalescence may come in a manner more direct than previously thought. The sun’s radiant energy separates charge in water, and this free charge demonstrably induces condensation. This condensation mechanism puts water as a central protagonist in life rather than as an incidental participant, and the...

  13. Molecules, water, and radiant energy: new clues for the origin of life.

    Science.gov (United States)

    Pollack, Gerald H; Figueroa, Xavier; Zhao, Qing

    2009-03-27

    We here examine the putative first step in the origin of life: the coalescence of dispersed molecules into a more condensed, organized state. Fresh evidence implies that the driving energy for this coalescence may come in a manner more direct than previously thought. The sun's radiant energy separates charge in water, and this free charge demonstrably induces condensation. This condensation mechanism puts water as a central protagonist in life rather than as an incidental participant, and thereby helps explain why life requires water.

  14. Energy Performance Assessment of Radiant Cooling System through Modeling and Calibration at Component Level

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Yasin [Malaviya National Institute of Technology (MNIT), Jaipur, India; Mathur, Jyotirmay [Malaviya National Institute of Technology (MNIT), Jaipur, India; Bhandari, Mahabir S [ORNL

    2016-01-01

    The paper describes a case study of an information technology office building with a radiant cooling system and a conventional variable air volume (VAV) system installed side by side so that performancecan be compared. First, a 3D model of the building involving architecture, occupancy, and HVAC operation was developed in EnergyPlus, a simulation tool. Second, a different calibration methodology was applied to develop the base case for assessing the energy saving potential. This paper details the calibration of the whole building energy model to the component level, including lighting, equipment, and HVAC components such as chillers, pumps, cooling towers, fans, etc. Also a new methodology for the systematic selection of influence parameter has been developed for the calibration of a simulated model which requires large time for the execution. The error at the whole building level [measured in mean bias error (MBE)] is 0.2%, and the coefficient of variation of root mean square error (CvRMSE) is 3.2%. The total errors in HVAC at the hourly are MBE = 8.7% and CvRMSE = 23.9%, which meet the criteria of ASHRAE 14 (2002) for hourly calibration. Different suggestions have been pointed out to generalize the energy saving of radiant cooling system through the existing building system. So a base case model was developed by using the calibrated model for quantifying the energy saving potential of the radiant cooling system. It was found that a base case radiant cooling system integrated with DOAS can save 28% energy compared with the conventional VAV system.

  15. Effects of Floor Covering Resistance of a Radiant Floor on System Energy and Exergy Performances

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Shukuya, Masanori; Olesen, Bjarne W.

    2016-01-01

    Floor covering resistance (material and thickness) can be influenced by subjective choices (architectural design, interior design, texture, etc.) with significant effects on the performance of a radiant heating and cooling system. To study the effects of floor covering resistance on system...... performance, a water-based radiant floor heating and cooling system (dry, wooden construction) was considered to be coupled to an air-to-water heat pump, and the effects of varying floor covering resistances (0.05 m2K/W, 0.09 m2K/W and 0.15 m2K/W) on system performance were analyzed in terms of energy...... and exergy. In order to achieve the same heating and cooling outputs, higher average water temperatures are required in the heating mode (and lower temperatures in the cooling mode) with increasing floor covering resistance. These temperature requirements decrease the heat pump’s performance (lower...

  16. Molecules, Water, and Radiant Energy: New Clues for the Origin of Life

    Directory of Open Access Journals (Sweden)

    Qing Zhao

    2009-03-01

    Full Text Available We here examine the putative first step in the origin of life: the coalescence of dispersed molecules into a more condensed, organized state. Fresh evidence implies that the driving energy for this coalescence may come in a manner more direct than previously thought. The sun’s radiant energy separates charge in water, and this free charge demonstrably induces condensation. This condensation mechanism puts water as a central protagonist in life rather than as an incidental participant, and thereby helps explain why life requires water.

  17. Clouds and the Earth's Radiant Energy System (CERES) Visualization Single Satellite Footprint (SSF) Plot Generator

    Science.gov (United States)

    Barsi, Julia A.

    1995-01-01

    The first Clouds and the Earth's Radiant Energy System (CERES) instrument will be launched in 1997 to collect data on the Earth's radiation budget. The data retrieved from the satellite will be processed through twelve subsystems. The Single Satellite Footprint (SSF) plot generator software was written to assist scientists in the early stages of CERES data analysis, producing two-dimensional plots of the footprint radiation and cloud data generated by one of the subsystems. Until the satellite is launched, however, software developers need verification tools to check their code. This plot generator will aid programmers by geolocating algorithm result on a global map.

  18. Bi-radiant oven: a low-energy oven system. Volume I. Development and assessment

    Energy Technology Data Exchange (ETDEWEB)

    DeWitt, D.P.; Peart, M.V.

    1980-04-01

    The Bi-Radiant Oven system has three important features which provide improved performance. First, the cavity walls are highly reflective rather than absorptive thereby allowing these surfaces to operate at cooler temperatures. Second, the heating elements, similar in construction to those in a conventional oven, but operating at much lower temperatures, provide a prescribed, balanced radiant flux to the top and bottom surfaces of the food product. And third, the baking and roasting utensil has a highly absorptive finish. Instrumentation and methods of measurements have been developed for obtaining the important oven and food parameters during baking: wall, oven air, food and element temperatures; food mass loss rate; irradiance distribution; and convection heat flux. Observations on an experimental oven are presented and discussed. Thermal models relating the irradiance distribution to oven parameters have been compared with measurements using a new heat flux gage developed for the project. Using the DOE recommended test procedures, oven efficiencies of 20 to 23% have been measured. The heating requirements have been determined for seven food types: biscuits, meat loaf, baked foods, apple crisp, cornbread, macaroni and cheese casserole, and cheese souffle. Comparison of energy use with a conventional electric oven shows that energy savings greater than 50% can be realized. Detailed energy balances have been performed on two foods - beef roasts and yellow cake. Consideration of consumer acceptability of this new oven concept have been addressed.

  19. Energy flow and thermal comfort in buildings: Comparison of radiant and air-based heating & cooling systems

    DEFF Research Database (Denmark)

    Le Dréau, Jérôme

    Heating and cooling terminals can be classified in two main categories: convective terminals (e.g air conditioning, active chilled beam, fan coil) and radiant terminals. The two terminals have different modes of heat transfer: the first one is mainly based on convection, whereas the second one...... is based on both radiation and convection. This thesis focuses on characterizing the heat transfer from the terminal towards the space and on the parameters influencing the effectiveness of terminals. Therefore the comfort conditions and energy consumption of four types of terminals (active chilled beam...... the cooling need of the radiant wall compared to the active chilled beam. These conclusions are valid for multi-storey and/or highly insulated buildings (R > 5 m2.K/W). In case of single-storey building with a low level of insulation, the effectiveness of radiant terminals is lower due to the larger back...

  20. Extinction of radiant energy by large atmospheric crystals with different shapes

    Science.gov (United States)

    Shefer, Olga

    2016-07-01

    The calculated results of extinction characteristics of visible and infrared radiation for large semi-transparent crystals are obtained by hybrid technique, which is a combination of the geometric optics method and the physical optics method. Energy and polarization characteristics of the radiation extinction in terms of the elements of the extinction matrix for individual large crystals and ensemble of crystals are discussed. Influences of particle shapes, aspect ratios, parameters of size distribution, complex refractive index, orientation of crystals, wavelength, and the polarization state of an incident radiation on the extinction are illustrated. It is shown that the most expressive and stable features of energy and polarization characteristics of the extinction are observed in the midinfrared region, despite the fact that the ice particles significantly absorb the radiant energy of this spectrum. It is demonstrated that the polarized extinction characteristics can reach several tens of percent at IR wavelengths. For the large crystals, the conditions of occurrence of the spectral behavior of the extinction coefficient in the visible, near-IR, and mid-IR wavelength ranges are determined.

  1. Tailor-made biopolymers porous scaffold fabrication for tissue engineering: application of radiant energy in the form of microwave under vacuum.

    Science.gov (United States)

    Jaya, S; Durance, T D

    2008-01-01

    Many methods are available for developing three-dimensional porous scaffolds using various polymeric materials for tissue-engineering applications. Each has its own advantages and disadvantages. Some of the available methods and their limitations were discussed briefly. This paper focuses on the scope of novel technology called radiant energy application under vacuum for the fabrication of three-dimensional porous scaffolds for tissue engineering applications. Radiant energy application in the form of microwave under vacuum has been shown to develop and maintain the porous structure in fruits and vegetables after dehydration, which produced the microstructure similar to the freeze dried materials. Same principle of applying radiant energy under vacuum was used on the biopolymeric gels to create tailor-made, porous scaffolds for biomedical purposes. It has many advantages over the other existing methods of scaffold fabrication. This paper also reviews the scaffolds design recently fabricated by the authors using radiant energy under vacuum.

  2. Numerical Modeling of Conjugate Thermogravitational Convection in a Closed System with a Radiant Energy Source in Conditions of Convective-Radiative Heat Exchange at the External Boundary

    OpenAIRE

    Nee Alexander

    2016-01-01

    Mathematical modeling of conjugate natural convection in a closed rectangular cavity with a radiant energy source in conditions of convective-radiative heat exchange at the external boundary was conducted. The radiant energy distribution was set by the Lambert’s law. Conduction and convection processes analysis showed that the air masses flow pattern is modified slightly over the time. The temperature increases in the gas cavity, despite the heat removal from the one of the external boundary....

  3. Automated Job Controller for Clouds and the Earth's Radiant Energy System (CERES) Production Processing

    Science.gov (United States)

    Gleason, J. L.; Hillyer, T. N.

    2011-12-01

    Clouds and the Earth's Radiant Energy System (CERES) is one of NASA's highest priority Earth Observing System (EOS) scientific instruments. The CERES science team will integrate data from the CERES Flight Model 5 (FM5) on the NPOESS Preparatory Project (NPP) in addition to the four CERES scanning instrument on Terra and Aqua. The CERES production system consists of over 75 Product Generation Executives (PGEs) maintained by twelve subsystem groups. The processing chain fuses CERES instrument observations with data from 19 other unique sources. The addition of FM5 to over 22 instrument years of data to be reprocessed from flight models 1-4 creates a need for an optimized production processing approach. This poster discusses a new approach, using JBoss and Perl to manage job scheduling and interdependencies between PGEs and external data sources. The new optimized approach uses JBoss to serve handler servlets which regulate PGE-level job interdependencies and job completion notifications. Additional servlets are used to regulate all job submissions from the handlers and to interact with the operator. Perl submission scripts are used to build Process Control Files and to interact directly with the operating system and cluster scheduler. The result is a reduced burden on the operator by algorithmically enforcing a set of rules that determine the optimal time to produce data products with the highest integrity. These rules are designed on a per PGE basis and periodically change. This design provides the means to dynamically update PGE rules at run time and increases the processing throughput by using an event driven controller. The immediate notification of a PGE's completion (an event) allows successor PGEs to launch at the proper time with minimal start up latency, thereby increasing computer system utilization.

  4. A full-scale experimental set-up for assessing the energy performance of radiant wall and active chilled beam for cooling buildings

    DEFF Research Database (Denmark)

    Le Dreau, Jerome; Heiselberg, Per; Jensen, Rasmus Lund

    2015-01-01

    in decreasing the cooling need of the radiant wall compared to the active chilled beam. It has also been observed that the type and repartition of heat load have an influence on the cooling demand. Regarding the comfort level, both terminals met the general requirements, except at high solar heat gains......Full-scale experiments under both steady-state and dynamic conditions have been performed to compare the energy performance of a radiant wall and an active chilled beam. From these experiments, it has been observed that the radiant wall is a more secure and efficient way of removing heat from...... the test room than the active chilled beam. The energy saving, which can be estimated to around 10%, is due to increased ventilation losses. The asymmetry between air and radiant temperature, the air temperature gradient and the possible short-circuit between inlet and outlet play an equally important role...

  5. Cloud Effects on Meridional Atmospheric Energy Budget Estimated from Clouds and the Earth's Radiant Energy System (CERES) Data

    Science.gov (United States)

    Kato, Seiji; Rose, Fred G.; Rutan, David A.; Charlock, Thomas P.

    2008-01-01

    The zonal mean atmospheric cloud radiative effect, defined as the difference of the top-of-atmosphere (TOA) and surface cloud radiative effects, is estimated from three years of Clouds and the Earth's Radiant Energy System (CERES) data. The zonal mean shortwave effect is small, though it tends to be positive (warming). This indicates that clouds increase shortwave absorption in the atmosphere, especially in midlatitudes. The zonal mean atmospheric cloud radiative effect is, however, dominated by the longwave effect. The zonal mean longwave effect is positive in the tropics and decreases with latitude to negative values (cooling) in polar regions. The meridional gradient of cloud effect between midlatitude and polar regions exists even when uncertainties in the cloud effect on the surface enthalpy flux and in the modeled irradiances are taken into account. This indicates that clouds increase the rate of generation of mean zonal available potential energy. Because the atmospheric cooling effect in polar regions is predominately caused by low level clouds, which tend to be stationary, we postulate that the meridional and vertical gradients of cloud effect increase the rate of meridional energy transport by dynamics in the atmosphere from midlatitude to polar region, especially in fall and winter. Clouds then warm the surface in polar regions except in the Arctic in summer. Clouds, therefore, contribute in increasing the rate of meridional energy transport from midlatitude to polar regions through the atmosphere.

  6. Thermal Comfort and Energy Consumption Using Different Radiant Heating/Cooling Systems in a Modern Office Building

    Science.gov (United States)

    Nemethova, Ema; Stutterecker, Werner; Schoberer, Thomas

    2017-06-01

    The aim of the study is to evaluate the potential of enhancing thermal comfort and energy consumption created by three different radiant systems in the newly-built Energetikum office building. A representative office, Simulation room 1/1, was selected from 6 areas equipped with portable sensor groups for the indoor environment monitoring. The presented data obtained from 3 reference weeks; the heating, transition and cooling periods indicate overheating, particularly during the heating and transition period. The values of the indoor air temperature during the heating and transition period could not meet the normative criteria according to standard EN 15251:2007 (cat. II.) for 15-30% of the time intervals evaluated. Consequently, a simulation model of the selected office was created and points to the possibilities of improving the control system, which can lead to an elimination of the problem with overheating. Three different radiant systems - floor heating/ cooling, a thermally active ceiling, and a near-surface thermally active ceiling were implemented in the model. A comparison of their effects on thermal comfort and energy consumption is presented in the paper.

  7. Climate Model Evaluation using New Datasets from the Clouds and the Earth's Radiant Energy System (CERES)

    Science.gov (United States)

    Loeb, Norman G.; Wielicki, Bruce A.; Doelling, David R.

    2008-01-01

    There are some in the science community who believe that the response of the climate system to anthropogenic radiative forcing is unpredictable and we should therefore call off the quest . The key limitation in climate predictability is associated with cloud feedback. Narrowing the uncertainty in cloud feedback (and therefore climate sensitivity) requires optimal use of the best available observations to evaluate and improve climate model processes and constrain climate model simulations over longer time scales. The Clouds and the Earth s Radiant Energy System (CERES) is a satellite-based program that provides global cloud, aerosol and radiative flux observations for improving our understanding of cloud-aerosol-radiation feedbacks in the Earth s climate system. CERES is the successor to the Earth Radiation Budget Experiment (ERBE), which has widely been used to evaluate climate models both at short time scales (e.g., process studies) and at decadal time scales. A CERES instrument flew on the TRMM satellite and captured the dramatic 1998 El Nino, and four other CERES instruments are currently flying aboard the Terra and Aqua platforms. Plans are underway to fly the remaining copy of CERES on the upcoming NPP spacecraft (mid-2010 launch date). Every aspect of CERES represents a significant improvement over ERBE. While both CERES and ERBE measure broadband radiation, CERES calibration is a factor of 2 better than ERBE. In order to improve the characterization of clouds and aerosols within a CERES footprint, we use coincident higher-resolution imager observations (VIRS, MODIS or VIIRS) to provide a consistent cloud-aerosol-radiation dataset at climate accuracy. Improved radiative fluxes are obtained by using new CERES-derived Angular Distribution Models (ADMs) for converting measured radiances to fluxes. CERES radiative fluxes are a factor of 2 more accurate than ERBE overall, but the improvement by cloud type and at high latitudes can be as high as a factor of 5

  8. Infant incubators and radiant warmers.

    Science.gov (United States)

    Bell, E F

    1983-10-01

    Incubators and radiant warmers are used to maintain the body temperature of newborn infants. This is best done so that the energy expended for metabolic heat production is minimized. The heat output of these devices is usually regulated by servocontrol to keep the skin temperature constant at a site on the abdomen where a thermistor probe is attached. In incubators, air temperature can also be controlled as an alternative to skin temperature servocontrol. Increased ambient humidity, heat shields and clothing have been used to decrease the evaporative or nonevaporative heat loss of infants in incubators under certain conditions. Double-walled incubators, by adding a second inner layer of Plexiglas, reduce radiant heat loss. They may also reduce total heat loss, but only if air temperature is controlled rather than skin temperature. The minimal oxygen consumption under a radiant warmer is the same or perhaps slightly higher than it is for the same infant in an incubator. Compared with incubators, the partition of body heat loss is quite different under radiant warmers. Radiant warmers increase convective and evaporative heat loss and insensible water loss but eliminate radiant heat loss or change it to net gain. A heat shield of thin polyethylene film can be used with a radiant warmer to reduce heat loss by convection and evaporation. The major advantage of the radiant warmer is the easy access it provides to critically-ill infants without disturbing the thermal environment. Its major disadvantage is the increase in insensible water loss produced by the radiant warmer. Most infants can be safely and adequately cared for in either incubator or radiant warmer bed.

  9. Performance of the Clouds and the Earth's Radiant Energy System (CERES) Flight Model 5 (FM5) instrument on NPP mission

    Science.gov (United States)

    Thomas, Susan; Priestley, Kory J.; Hess, Phillip C.; Wilson, Robert S.; Smith, Nathaniel P.; Timcoe, Mark G.; Shankar, Mohan; Walikainen, Dale R.

    2012-09-01

    Clouds and the Earth's Radiant Energy System (CERES) instrument was designed to provide accurate measurements for the long-term monitoring of Earth's radiation energy budget. Flight Model 5, the sixth of the CERES instrument was launched aboard the NPP spacecraft on October 2011 and it has started the Earth-viewing measurements on January 26, 2012. The CERES instrument with the three scanning sensors measure radiances in 0.3 to 5.0 micron region with Shortwave sensor, 0.3 to elevation offset in the sensor measurement will be determined from the spacecraft pitch manuveur activity viewing the deep space. This paper covers the early-orbit checkout activities and the overall performance of the CERES-FM5 instrument. The postlaunch calibration and the validation results from the instrument are presented.

  10. Energy transfer in double plate system dynamics

    Institute of Scientific and Technical Information of China (English)

    Katica (Stevanovic) Hedrih

    2008-01-01

    The study of energy transfer between coupled subsystems in a hybrid system is very important for applications. This paper presents an analytical analysis of energy transfer between plates of a visco-elastically connected double-plate system in free transversal vibrations. The analytical analysis shows that the visco-elastic connection between plates is responsible for the appearance of two-frequency regime in the time function, which corresponds to one eigen amplitude function of one mode, and also that time functions of different vibration modes are uncoupled, but energy transfer between plates in one eigen mode appears. It was shown for each shape of vibrations. Series of the two Lyapunov exponents corresponding to the one eigen amplitude mode are expressed by using the energy of the corresponding eigen amplitude time component.

  11. Radiant Energy Measurements from a Scaled Jet Engine Axisymmetric Exhaust Nozzle for a Baseline Code Validation Case

    Science.gov (United States)

    Baumeister, Joseph F.

    1994-01-01

    A non-flowing, electrically heated test rig was developed to verify computer codes that calculate radiant energy propagation from nozzle geometries that represent aircraft propulsion nozzle systems. Since there are a variety of analysis tools used to evaluate thermal radiation propagation from partially enclosed nozzle surfaces, an experimental benchmark test case was developed for code comparison. This paper briefly describes the nozzle test rig and the developed analytical nozzle geometry used to compare the experimental and predicted thermal radiation results. A major objective of this effort was to make available the experimental results and the analytical model in a format to facilitate conversion to existing computer code formats. For code validation purposes this nozzle geometry represents one validation case for one set of analysis conditions. Since each computer code has advantages and disadvantages based on scope, requirements, and desired accuracy, the usefulness of this single nozzle baseline validation case can be limited for some code comparisons.

  12. Energy of plate tectonics calculation and projection

    Directory of Open Access Journals (Sweden)

    N. H. Swedan

    2013-02-01

    Full Text Available Mathematics and observations suggest that the energy of the geological activities resulting from plate tectonics is equal to the latent heat of melting, calculated at mantle's pressure, of the new ocean crust created at midocean ridges following sea floor spreading. This energy varies with the temperature of ocean floor, which is correlated with surface temperature. The objective of this manuscript is to calculate the force that drives plate tectonics, estimate the energy released, verify the calculations based on experiments and observations, and project the increase of geological activities with surface temperature rise caused by climate change.

  13. Self-similar plates: Casimir energies

    CERN Document Server

    Shajesh, K V; Cavero-Peláez, Inés; Parashar, Prachi

    2016-01-01

    We construct various self-similar configurations using parallel $\\delta$-function plates and show that it is possible to evaluate the Casimir interaction energy of these configurations using the idea of self-similarity alone. We restrict our analysis to interactions mediated by a scalar field, but the extension to electromagnetic field is immediate. Our work unveils an easy and powerful method that can be easily employed to calculate the Casimir energies of a class of self-similar configurations. As a highlight, in an example, we determine the Casimir interaction energy of a stack of parallel plates constructed by positioning $\\delta$-function plates at the points constituting the Cantor set, a prototype of a fractal. This, to our knowledge, is the first time that the Casimir energy of a fractal configuration has been reported. Remarkably, the Casimir energy of some of the configurations we consider turn out to be positive, and a few even have zero Casimir energy. For the case of positive Casimir energy that ...

  14. Clouds and the Earth's Radiant Energy System (CERES) algorithm theoretical basis document. Volume 1; Overviews (subsystem 0)

    Science.gov (United States)

    Wielicki, Bruce A. (Principal Investigator); Barkstrom, Bruce R. (Principal Investigator); Baum, Bryan A.; Cess, Robert D.; Charlock, Thomas P.; Coakley, James A.; Green, Richard N.; Lee, Robert B., III; Minnis, Patrick; Smith, G. Louis

    1995-01-01

    The theoretical bases for the Release 1 algorithms that will be used to process satellite data for investigation of the Clouds and the Earth's Radiant Energy System (CERES) are described. The architecture for software implementation of the methodologies is outlined. Volume 1 provides both summarized and detailed overviews of the CERES Release 1 data analysis system. CERES will produce global top-of-the-atmosphere shortwave and longwave radiative fluxes at the top of the atmosphere, at the surface, and within the atmosphere by using the combination of a large variety of measurements and models. The CERES processing system includes radiance observations from CERES scanning radiometers, cloud properties derived from coincident satellite imaging radiometers, temperature and humidity fields from meteorological analysis models, and high-temporal-resolution geostationary satellite radiances to account for unobserved times. CERES will provide a continuation of the ERBE record and the lowest error climatology of consistent cloud properties and radiation fields. CERES will also substantially improve our knowledge of the Earth's surface radiation budget.

  15. Numerical Modeling of Conjugate Thermogravitational Convection in a Closed System with a Radiant Energy Source in Conditions of Convective-Radiative Heat Exchange at the External Boundary

    Directory of Open Access Journals (Sweden)

    Nee Alexander

    2016-01-01

    Full Text Available Mathematical modeling of conjugate natural convection in a closed rectangular cavity with a radiant energy source in conditions of convective-radiative heat exchange at the external boundary was conducted. The radiant energy distribution was set by the Lambert’s law. Conduction and convection processes analysis showed that the air masses flow pattern is modified slightly over the time. The temperature increases in the gas cavity, despite the heat removal from the one of the external boundary. According to the results of the integral heat transfer analysis were established that the average Nusselt number (Nuav increasing occurs up to τ = 200 (dimensionless time. Further Nuav has changed insignificantly due to the temperature field equalization near the interfaces “gas – wall”.

  16. Potential Use of Radiant Walls to Transfer Energy Between two Building Zones

    DEFF Research Database (Denmark)

    Le Dreau, Jerome; Heiselberg, Per

    2011-01-01

    Due to a reduced energy demand in low energy buildings, low temperature heating and high temperature cooling can be used to control thermal comfort. Nevertheless, highly varying heat loads due to solar radiation can create sometimes an imbalanced energy demand inside the building. Instead of being...... considered as a disturbance, this asymmetry can be used as a heat source for another zone of the building. By means of computer simulations, the possibility of shifting the energy demand between two office rooms with different thermal loads has been studied. Due to the small temperature difference between...

  17. Spectral Characterizations of the Clouds and the Earth's Radiant Energy System (CERES) Thermistor Bolometers using Fourier Transform Spectrometer (FTS) Techniques

    Science.gov (United States)

    Thornhill, K. Lee; Bitting, Herbert; Lee, Robert B., III; Paden, Jack; Pandey, Dhirendra K.; Priestley, Kory J.; Thomas, Susan; Wilson, Robert S.

    1998-01-01

    Fourier Transform Spectrometer (FTS) techniques are being used to characterize the relative spectral response, or sensitivity, of scanning thermistor bolometers in the infrared (IR) region (2 - >= 100-micrometers). The bolometers are being used in the Clouds and the Earth's Radiant Energy System (CERES) program. The CERES measurements are designed to provide precise, long term monitoring of the Earth's atmospheric radiation energy budget. The CERES instrument houses three bolometric radiometers, a total wavelength (0.3- >= 150-micrometers) sensor, a shortwave (0.3-5-micrometers) sensor, and an atmospheric window (8-12-micrometers) sensor. Accurate spectral characterization is necessary for determining filtered radiances for longwave radiometric calibrations. The CERES bolometers spectral response's are measured in the TRW FTS Vacuum Chamber Facility (FTS - VCF), which uses a FTS as the source and a cavity pyroelectric trap detector as the reference. The CERES bolometers and the cavity detector are contained in a vacuum chamber, while the FTS source is housed in a GN2 purged chamber. Due to the thermal time constant of the CERES bolometers, the FTS must be operated in a step mode. Data are acquired in 6 IR spectral bands covering the entire longwave IR region. In this paper, the TRW spectral calibration facility design and data measurement techniques are described. Two approaches are presented which convert the total channel FTS data into the final CERES spectral characterizations, producing the same calibration coefficients (within 0.1 percent). The resulting spectral response curves are shown, along with error sources in the two procedures. Finally, the impact of each spectral response curve on CERES data validation will be examined through analysis of filtered radiance values from various typical scene types.

  18. Radiant flux density, energy density, and fuel consumption in mixed-oak forest surface fires

    Science.gov (United States)

    R.L. Kremens; M.B. Dickinson; A.S. Bova

    2012-01-01

    Closing the wildland fire heat budget involves characterising the heat source and energy dissipation across the range of variability in fuels and fire behaviour. Meeting this challenge will lay the foundation for predicting direct ecological effects of fires and fire-atmosphere coupling. In this paper, we focus on the relationships between the fire radiation field, as...

  19. 16 CFR 1209.6 - Test procedures for critical radiant flux.

    Science.gov (United States)

    2010-01-01

    ... ACT REGULATIONS INTERIM SAFETY STANDARD FOR CELLULOSE INSULATION The Standard § 1209.6 Test procedures... radiant flux of exposed attic floor insulation using a radiant heat energy source. (a) Apparatus and... attic floor insulation specimen. The radiant panel generates a radiant energy flux distribution ranging...

  20. Infrared radiant ceramic plaques; Plaques radiantes ceramiques a infrarouge

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2000-05-01

    Infrared plaques developed by MORGAN MATROC can now produce radiant heat from both natural and bottled gas with substantially lower NOx levels, and greater fuel efficiency and cleanliness, than other mass produced gas burning systems. The properties of this ceramic system, in particular very low thermal conductivity, allied to the infrared process for heat conversion, result in efficient radiation of energy. Morgan Matroc now claims half of the world-wide market of infrared plaque. (authors)

  1. Radiant Image Simulation of Pulverized Coal Combustion in Blast Furnace Raceway

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The relationship between two-dimensional radiant image and three-dimensional radiant energy in blast furnace raceway was studied by numerical simulation of combustion process. Taking radiant image as radiant boundary for numerical simulation of combustion process, the uneven radiation parameter can be calculated. A method to examine three-dimensional temperature distribution in blast furnace raceway was put forward by radiant image processing. The numeral temperature field matching the real combustion can be obtained by proposed numeric image processing technique.

  2. Preliminary study of a radiantly heated fluidized bed for the production of high purity silicon

    Science.gov (United States)

    Levenspiel, O.; Larson, M.; Zhang, G. T.; Ouyang, F.

    1983-01-01

    The preparation of very pure silicon from silane (SIH4) using radiant heating of the hot silicon particles of a fluidized bed is discussed. The fraction of electrical energy supplied to the heater which is actually absorbed by the particles and the heat transfer coefficient between the hot bed and the cool distributor plate were investigated. The experimental design is presented and the results of the study are summarized.

  3. The Oklahoma Field Test: Air-conditioning electricity savings from standard energy conservation measures, radiant barriers, and high-efficiency window air conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Ternes, M.P.; Levins, W.P.

    1992-08-01

    A field test Involving 104 houses was performed in Tulsa, Oklahoma, to measure the air-conditioning electricity consumption of low-income houses equipped with window air conditioners, the reduction in this electricity consumption attributed to the installation of energy conservation measures (ECMS) as typically installed under the Oklahoma Weatherization Assistance Program (WAP), and the reduction achieved by the replacement of low-efficiency window air conditioners with high-efficiency units and the installation of attic radiant barriers. Air-conditioning electricity consumption and indoor temperature were monitored weekly during the pre-weatherization period (June to September 1988) and post-weatherization period (May to September 1989). House energy consumption models and regression analyses were used to normalize the air-conditioning electricity savings to average outdoor temperature conditions and the pre-weatherization indoor temperature of each house. The following conclusions were drawn from the study: (1) programs directed at reducing air-conditioning electricity consumption should be targeted at clients with high consumption to improve cost effectiveness; (2) replacing low-efficiency air conditioners with high-efficiency units should be considered an option in a weatherization program directed at reducing air-conditioning electricity consumption; (3) ECMs currently being installed under the Oklahoma WAP (chosen based on effectiveness at reducing space-heating energy consumption) should continue to be justified based on their space-heating energy savings potential only; and (4) attic radiant barriers should not be included in the Oklahoma WAP if alternatives with verified savings are available or until further testing demonstrates energy savings or other benefits in this typo of housing.

  4. Electromagnetic semitransparent $\\delta$-function plate: Casimir interaction energy between parallel infinitesimally thin plates

    CERN Document Server

    Parashar, Prachi; Shajesh, K V; Schaden, M

    2012-01-01

    We derive boundary conditions for electromagnetic fields on a $\\delta$-function plate. The optical properties of such a plate are shown to necessarily be anisotropic in that they only depend on the transverse properties of the plate. We unambiguously obtain the boundary conditions for a perfectly conducting $\\delta$-function plate in the limit of infinite dielectric response. We show that a material does not "optically vanish" in the thin-plate limit. The thin-plate limit of a plasma slab of thickness $d$ with plasma frequency $\\omega_p^2=\\zeta_p/d$ reduces to a $\\delta$-function plate for frequencies ($\\omega=i\\zeta$) satisfying $\\zeta d \\ll \\sqrt{\\zeta_p d} \\ll 1$. We show that the Casimir interaction energy between two parallel perfectly conducting $\\delta$-function plates is the same as that for parallel perfectly conducting slabs. Similarly, we show that the interaction energy between an atom and a perfect electrically conducting $\\delta$-function plate is the usual Casimir-Polder energy, which is verifi...

  5. Weak Coupling Casimir Energies for Finite Plate Configurations

    CERN Document Server

    Wagner, Jef; Parashar, Prachi

    2008-01-01

    We derive and use an extremely simplified formula for the interaction Casimir energy for two separate bodies in the weak coupling regime for massless scalar fields. We derive closed form solutions for a general arrangement of two $\\delta$-function plates finite in one direction and infinite in another. We examine the situation of two parallel plates finite in both transverse directions.

  6. Solar-driven high temperature radiant cooling

    Institute of Scientific and Technical Information of China (English)

    SONG ZhaoPei; WANG RuZhu; ZHAI XiaoQiang

    2009-01-01

    Solar energy is widely used as one of the most important renewable energy. In addition to the growing applications of solar PV and solar water heater, solar cooling is also considered very valuable and the related researches are developing fast because of the synchronism between solar irradiance and building cooling load. Current studies mainly focus on the high temperature solar collector technique and heat-driven cooling technique, while little concern has been paid to the transport process of cooling power. In this paper, the high temperature radiant cooling is studied as an alternative way for transporting cooling power, and the performance of the combination of radiant ceiling and solar cooling is also studied. From simulation and theoretical analysis results, high temperature radiant cooling terminal shows better cooling power transportation ability against conventional air-conditioning terminal, and its thermal comfort is improved. Experiment results indicate that radiant cooling can enhance the chiller's COP (Coefficient of Performance) by 17% and cooling power regeneration by 50%.According to analysis in this paper, high temperature radiant cooling is proved to be suitable for solar cooling system, and out work can serve as a reference for later system design and promotion.

  7. The Oklahoma Field Test: Air-Conditioning Electricity Savings from Standard Energy Conservation Measures, Radiant Barriers, and High-Efficiency Window Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Ternes, M.P.

    1992-01-01

    A field test involving 104 houses was performed in Tulsa, Oklahoma, to measure the air-conditioning electricity consumption of low-income houses equipped with window air conditioners, the reduction in this electricity consumption attributed to the installation of energy conservation measures (ECMs) as typically installed under the Oklahoma Weatherization Assistance Program (WAP), and the reduction achieved by the replacement of low-efficiency window air conditioners with high-efficiency units and the installation of attic radiant barriers. Air-conditioning electricity consumption and indoor temperature were monitored weekly during the pre-weatherization period (June to September 1988) and post-weatherization period (May to September 1989). House energy consumption models and regression analyses were used to normalize the air-conditioning electricity savings to average outdoor temperature conditions and the pre-weatherization indoor temperature of each house. The average measured pre-weatherization air-conditioning electricity consumption was 1664 kWh/year ($119/year). Ten percent of the houses used less than 250 kWh/year, while another 10% used more than 3000 kWh/year. An average reduction in air-conditioning electricity consumption of 535 kWh/year ($38/year and 28% of pre-weatherization consumption) was obtained from replacement of one low-efficiency window air conditioner (EER less than 7.0) per house with a high-efficiency unit (EER greater than 9.0). For approximately the same cost, savings tripled to 1503 kWh/year ($107/year and 41% of pre-weatherization consumption) in those houses with initial air-conditioning electricity consumption greater than 2750 kWh/year. For these houses, replacement of a low-efficiency air conditioner with a high-efficiency unit was cost effective using the incremental cost of installing a new unit now rather than later; the average installation cost for these houses under a weatherization program was estimated to be $786. The

  8. Compound Floor Radiant Heating System of Solar Energy, Heat Pump and Phase Change Energy Storage%太阳能热泵相变储能复合地板辐射采暖系统

    Institute of Scientific and Technical Information of China (English)

    王长宁

    2016-01-01

    太阳能地板辐射采暖系统与相变储能技术结合使用是新能源利用的一种重要方法。介绍了一种太阳能、热泵、低谷电辅热与相变储能地板联合运行的复合地板辐射采暖系统;讨论了系统组成、运行原理以及运行流程;分析了该采暖系统在节能环保、室内热舒适性等方面的优点;展望了其良好的发展前景。%Combing solar radiant floor heating system with phase change energy storage technology is an important method of new energy utilization. A compound floor radiant heating system of solar energy, heat pump, off-peak electricity and phase change energy storage is introduced. The system composition, working principle and operation process are discussed. Advantages of the heating system in the aspects of energy saving, environmental protection, indoor thermal comfort are analyzed. Moreover, a view of good ap-plication prospect is presented.

  9. An electromechanical finite element model for piezoelectric energy harvester plates

    Science.gov (United States)

    De Marqui Junior, Carlos; Erturk, Alper; Inman, Daniel J.

    2009-10-01

    Vibration-based energy harvesting has been investigated by several researchers over the last decade. The goal in this research field is to power small electronic components by converting the waste vibration energy available in their environment into electrical energy. Recent literature shows that piezoelectric transduction has received the most attention for vibration-to-electricity conversion. In practice, cantilevered beams and plates with piezoceramic layers are employed as piezoelectric energy harvesters. The existing piezoelectric energy harvester models are beam-type lumped parameter, approximate distributed parameter and analytical distributed parameter solutions. However, aspect ratios of piezoelectric energy harvesters in several cases are plate-like and predicting the power output to general (symmetric and asymmetric) excitations requires a plate-type formulation which has not been covered in the energy harvesting literature. In this paper, an electromechanically coupled finite element (FE) plate model is presented for predicting the electrical power output of piezoelectric energy harvester plates. Generalized Hamilton's principle for electroelastic bodies is reviewed and the FE model is derived based on the Kirchhoff plate assumptions as typical piezoelectric energy harvesters are thin structures. Presence of conductive electrodes is taken into account in the FE model. The predictions of the FE model are verified against the analytical solution for a unimorph cantilever and then against the experimental and analytical results of a bimorph cantilever with a tip mass reported in the literature. Finally, an optimization problem is solved where the aluminum wing spar of an unmanned air vehicle (UAV) is modified to obtain a generator spar by embedding piezoceramics for the maximum electrical power without exceeding a prescribed mass addition limit.

  10. Minimum wall pressure coefficient of orifice plate energy dissipater

    Institute of Scientific and Technical Information of China (English)

    Wan-zheng Ai; Jia-hong Wang

    2015-01-01

    Orifice plate energy dissipaters have been successfully used in large-scale hydropower projects due to their simple structure, convenient construction procedure, and high energy dissipation ratio. The minimum wall pressure coefficient of an orifice plate can indirectly reflect its cavitation characteristics:the lower the minimum wall pressure coefficient is, the better the ability of the orifice plate to resist cavitation damage is. Thus, it is important to study the minimum wall pressure coefficient of the orifice plate. In this study, this coefficient and related parameters, such as the contraction ratio, defined as the ratio of the orifice plate diameter to the flood-discharging tunnel diameter;the relative thickness, defined as the ratio of the orifice plate thickness to the tunnel diameter;and the Reynolds number of the flow through the orifice plate, were theoretically analyzed, and their relationships were obtained through physical model experiments. It can be concluded that the minimum wall pressure coefficient is mainly dominated by the contraction ratio and relative thickness. The lower the contraction ratio and relative thickness are, the larger the minimum wall pressure coefficient is. The effects of the Reynolds number on the minimum wall pressure coefficient can be neglected when it is larger than 105. An empirical expression was presented to calculate the minimum wall pressure coefficient in this study.

  11. Minimum wall pressure coefficient of orifice plate energy dissipater

    Directory of Open Access Journals (Sweden)

    Wan-zheng AI

    2015-01-01

    Full Text Available Orifice plate energy dissipaters have been successfully used in large-scale hydropower projects due to their simple structure, convenient construction procedure, and high energy dissipation ratio. The minimum wall pressure coefficient of an orifice plate can indirectly reflect its cavitation characteristics: the lower the minimum wall pressure coefficient is, the better the ability of the orifice plate to resist cavitation damage is. Thus, it is important to study the minimum wall pressure coefficient of the orifice plate. In this study, this coefficient and related parameters, such as the contraction ratio, defined as the ratio of the orifice plate diameter to the flood-discharging tunnel diameter; the relative thickness, defined as the ratio of the orifice plate thickness to the tunnel diameter; and the Reynolds number of the flow through the orifice plate, were theoretically analyzed, and their relationships were obtained through physical model experiments. It can be concluded that the minimum wall pressure coefficient is mainly dominated by the contraction ratio and relative thickness. The lower the contraction ratio and relative thickness are, the larger the minimum wall pressure coefficient is. The effects of the Reynolds number on the minimum wall pressure coefficient can be neglected when it is larger than 105. An empirical expression was presented to calculate the minimum wall pressure coefficient in this study.

  12. Radiant Floor Cooling Systems

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.

    2008-01-01

    In many countries, hydronic radiant floor systems are widely used for heating all types of buildings such as residential, churches, gymnasiums, hospitals, hangars, storage buildings, industrial buildings, and smaller offices. However, few systems are used for cooling.This article describes a floor...... cooling system that includes such considerations as thermal comfort of the occupants, which design parameters will influence the cooling capacity and how the system should be controlled. Examples of applications are presented....

  13. Casimir energies of self-similar plate configurations

    Science.gov (United States)

    Shajesh, K. V.; Brevik, Iver; Cavero-Peláez, Inés; Parashar, Prachi

    2016-09-01

    We construct various self-similar configurations using parallel δ -function plates and show that it is possible to evaluate the Casimir interaction energy of these configurations using the idea of self-similarity alone. We restrict our analysis to interactions mediated by a scalar field, but the extension to the electromagnetic field is immediate. Our work unveils an easy and powerful method that can be easily employed to calculate the Casimir energies of a class of self-similar configurations. As a highlight, in an example, we determine the Casimir interaction energy of a stack of parallel plates constructed by positioning δ -function plates at the points constituting the Cantor set, a prototype of a fractal. This, to our knowledge, is the first time that the Casimir energy of a fractal configuration has been reported. Remarkably, the Casimir energy of some of the configurations we consider turn out to be positive, and a few even have zero Casimir energy. For the case of positive Casimir energy that is monotonically decreasing as the stacking parameter increases, the interpretation is that the pressure of vacuum tends to inflate the infinite stack of plates. We further support our results, derived using the idea of self-similarity alone, by rederiving them using the Green's function formalism. These expositions gives us insight into the connections between the regularization methods used in quantum field theories and regularized sums of divergent series in number theory.

  14. Chaotic dynamics of a classical radiant cavity

    CERN Document Server

    Benenti, G; Guarneri, I; Benenti, Giuliano; Casati, Giulio; Guarneri, Italo

    1999-01-01

    The statistical properties of a classical electromagnetic field in interaction with matter are numerically investigated on a one-dimensional model of a radiant cavity, conservative and with finite total energy. Our results suggest a trend towards equipartition of energy, with the relaxation times of the normal modes of the cavity increasing with the mode frequency according to a law, the form of which depends on the shape of the charge distribution.

  15. Influence of radiant energy exchange on the determination of convective heat transfer rates to Orbiter leeside surfaces during entry

    Science.gov (United States)

    Throckmorton, D. A.

    1982-01-01

    Temperatures measured at the aerodynamic surface of the Orbiter's thermal protection system (TPS), and calorimeter measurements, are used to determine heating rates to the TPS surface during atmospheric entry. On the Orbiter leeside, where convective heating rates are low, it is possible that a significant portion of the total energy input may result from solar radiation, and for the wing, cross radiation from the hot (relatively) Orbiter fuselage. In order to account for the potential impact of these sources, values of solar- and cross-radiation heat transfer are computed, based upon vehicle trajectory and attitude information and measured surface temperatures. Leeside heat-transfer data from the STS-2 mission are presented, and the significance of solar radiation and fuselage-to-wing cross-radiation contributions to total energy input to Orbiter leeside surfaces is assessed.

  16. Calculating the Solar Energy of a Flat Plate Collector

    Directory of Open Access Journals (Sweden)

    Ariane Rosario

    2014-09-01

    Full Text Available The amount of solar energy that could be obtained by a flat plate solar collector of one square meter dimension is calculated in three different locations: Tampa FL, Fairbanks AL, and Pontianak Indonesia, considering the varying sunset time for each day of the year. The results show that if the collectors are placed near the equator, more total energy could be obtained. In fact, by placing a solar collector in Pontianak, Indonesia 12.42% more solar energy can be obtained than by placing it in Tampa and 96.9% more solar energy than Alaska.

  17. Radiative effects of African dust and smoke observed from Clouds and the Earth's Radiant Energy System (CERES) and Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) data

    Science.gov (United States)

    Yorks, John E.; McGill, Matt; Rodier, Sharon; Vaughan, Mark; Hu, Yongxiang; Hlavka, Dennis

    2009-09-01

    Cloud and aerosol effects have a significant impact on the atmospheric radiation budget in the tropical Atlantic because of the spatial and temporal extent of desert dust and smoke from biomass burning in the atmosphere. The influences of African dust and smoke aerosols on cloud radiative properties over the tropical Atlantic Ocean were analyzed for the month of July for 3 years (2006-2008) using colocated data collected by the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) and Clouds and the Earth's Radiant Energy System (CERES) instruments on the Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) and Aqua satellites. Aerosol layer height and type can be accurately determined using CALIOP data through directly measured parameters such as optical depth, volume depolarization ratio, attenuated backscatter, and color ratio. On average, clouds below 5 km had a daytime instantaneous shortwave (SW) radiative flux of 270.2 ± 16.9 W/m2 and thin cirrus clouds had a SW radiative flux of 208.0 ± 12.7 W/m2. When dust aerosols interacted with clouds below 5 km, as determined from CALIPSO, the SW radiative flux decreased to 205.4 ± 13.0 W/m2. Similarly, smoke aerosols decreased the SW radiative flux of low clouds to a value of 240.0 ± 16.6 W/m2. These decreases in SW radiative flux were likely attributed to the aerosol layer height and changes in cloud microphysics. CALIOP lidar observations, which more accurately identify aerosol layer height than passive instruments, appear essential for better understanding of cloud-aerosol interactions, a major uncertainty in predicting the climate system.

  18. 微波及辐射真空干燥过程中的干燥动力学及能量消耗%Drying Kinetics and Energy Consumption in Vacuum Drying Process with Microwave and Radiant Heating

    Institute of Scientific and Technical Information of China (English)

    M. Kamel; J.I. Lombra(n)a; C. de Elvira; R. Rodr(i)guez

    2004-01-01

    The general objective of this work is to analyze energy input in a vacuum process with the incorporation of microwave heating. Thus, necessary criteria for designing an efficient freeze-drying operation are considered through the analysis of strategies based on the combination of different intensities of radiant and microwave heating.The other aim of this research topic is to study the kinetics of drying in relation to mass transfer parameters.Five freeze-drying strategies using both heating systems were used. Consequently, energy input could be related to diffusivity coefficients, temperature and pressure profiles during dehydration of the product and analyzed in comparison to a conventional freeze-drying process.

  19. The Estimation of Vibrational Energy of Two Coupled (Welded Plates Using Statistical Energy Analysis

    Directory of Open Access Journals (Sweden)

    Hawraa S. Ibraham

    2011-01-01

    Full Text Available This paper deals with a method called Statistical Energy Analysis that can be applied to the mechanical and acoustical systems like buildings, bridges and aircrafts …etc. S.E.A as a tool can be applied to the resonant systems in the circumstances of high frequency or/and complex structure». The parameters of S.E.A such as coupling loss factor, internal loss factor, modal density and input power are clarified in this work ; coupled plate sub-systems and explanations are presented for these parameters. The developed system is assumed to be resonant, conservative, linear and there is an equipartition of energy between all the resonant modes within a given frequency band in a given sub-system. The aim of this work is to find the energy stored in the sub-systems for two coupled (welded plates in rectangular angle systems and study the effect of changing sub-systems dimensions, the results shows that as surface area of directly driven plates A1 increases energy level of plate 1 increases while a reduction in the energy level of indirectly driven plate (plate 2 is noticed. This is because of the strength of coupling decreases towards the weak coupling condition and this leads to a reduction in the power transferred from plate 1 to plate 2 and consequently a lower energy level for plate 2. In addition the effect of changing the internal loss factor for a range of (0.00001-0.1 causes a reduction of the values of energy level in these sub-systems. because the increasing of internal loss factor values led to the increasing of the material resistance and that will dissipate the energy flow across those sub-systems. A comparison is made between S.E.A models built by FORTRAN program and Finite Element model solved by ANSYS package.

  20. Experimental and Numerical Study of the Radiant Induction-Unit and the Induction Radiant Air-Conditioning System

    Directory of Open Access Journals (Sweden)

    Qiang Si

    2016-12-01

    Full Text Available In this paper we proposed the novel air-conditioning system which combined induction ventilation and radiant air-conditioning. The indoor terminal device is the radiant induction-unit (RIDU. The RIDU is the induction unit combined with the pore radiant panel on which the copper pipes with rigid aluminum diffusion fins are installed. The two-stage evaporator chiller with the non-azeotropic mixture refrigerant is utilized in the system to reduce the initial investment in equipment. With the performance test and the steady state heat transfer model based on the theory of radiative heat transfer, the relationship between the induction ratio of the RIDU and the characteristic of the air supply was studied. Based on this, it is verified that the RIDU has a lower dew-point temperature and better anti-condensation performance than a traditional plate-type radiant panel. The characteristics of the radiation and convection heat transfer of the RIDU were studied. The total heat exchange of the RIDU can be 16.5% greater than that of the traditional plate-type radiant terminal.

  1. PERFORMANCE EVALUATION OF CEILING RADIANT COOLING SYSTEM IN COMPOSITE CLIMATE

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Anuj [Malaviya National Institute of Technology (MNIT), Jaipur, India; Mathur, Jyotirmay [Malaviya National Institute of Technology (MNIT), Jaipur, India; Bhandari, Mahabir S [ORNL

    2015-01-01

    Radiant cooling systems are proving to be an energy efficient solution due to higher thermal capacity of cooling fluid especially for the buildings that require individual zone controls and where the latent loads are moderate. The Conventional air conditioners work at very low temperature i.e.5-8 c (refrigerant evaporator inlet) while the radiant cooling systems, also referred as high temperature cooling system, work at high temperatures i.e. 14-18 c. The radiant cooling systems can maintain lower MRT (Mean Radiant Temperature) as ceiling panels maintain uniform temperature gradient inside room and provide higher human comfort. The radiant cooling systems are relatively new systems and their operation and energy savings potential are not quantified for a large number of buildings and operational parameters. Moreover, there are only limited numbers of whole building simulation studies have been carried out for these systems to have a full confidence in the capability of modelling tools to simulate these systems and predict the impact of various operating parameters. Theoretically, savings achieve due to higher temperature set point of chilled water, which reduces chiller-running time. However, conventional air conditioner runs continuously to maintain requisite temperature. In this paper, experimental study for performance evaluation of radiant cooling system carried out on system installed at Malaviya National Institute of Technology Jaipur. This paper quantifies the energy savings opportunities and effective temperature by radiant cooling system at different chilled water flow rates and temperature range. The data collected/ analysed through experimental study will used for calibration and validation of system model of building prepared in building performance simulation software. This validated model used for exploring optimized combinations of key parameters for composite climate. These optimized combinations will used in formulation of radiant cooling system

  2. Solar Thermal Radiant Heating at Pohakuloa Training Area

    Science.gov (United States)

    2010-06-01

    Solar collector panels. • Sizing the array: Using thermal storage of 256,000 BTU/day and 4’ x 10’ flat panel collectors with output of...be arranged side-by-side on the south- facing pitch of roof. – Racked at 30 angle to maximize winter sun. Flat plate solar collectors E2S2– June 2010...radiant heat flooring project will combine solar thermal hot water system with in-floor radiant heating. – Flooring heat only; no domestic water. – Flat

  3. Casimir interaction energies for magneto-electric \\delta-function plates

    CERN Document Server

    Milton, Kimball A; Schaden, Martin; Shajesh, K V

    2013-01-01

    We present boundary conditions for the electromagnetic fields on a \\delta-function plate, having both electric and magnetic properties, sandwiched between two magneto-electric semi-infinite half spaces. The optical properties for an isolated \\delta-function plate are shown to be independent of the longitudinal material properties of the plate. The Casimir-Polder energy between an isotropically polarizable atom and a magneto-electric \\delta-function plate is attractive for a purely electric \\delta-function plate, repulsive for a purely magnetic \\delta-function plate, and vanishes for the simultaneous perfect conductor limit of both electric and magnetic properties of the \\delta-function plate. The interaction energy between two identical \\delta-function plates is always attractive. It can be attractive or repulsive when the plates have electric and magnetic properties interchanged and reproduces Boyer's result for the interaction energy between perfectly conducting electric and magnetic plates. The change in t...

  4. Thermal model of attic systems with radiant barriers

    Energy Technology Data Exchange (ETDEWEB)

    Wilkes, K.E.

    1991-07-01

    This report summarizes the first phase of a project to model the thermal performance of radiant barriers. The objective of this phase of the project was to develop a refined model for the thermal performance of residential house attics, with and without radiant barriers, and to verify the model by comparing its predictions against selected existing experimental thermal performance data. Models for the thermal performance of attics with and without radiant barriers have been developed and implemented on an IBM PC/AT computer. The validity of the models has been tested by comparing their predictions with ceiling heat fluxes measured in a number of laboratory and field experiments on attics with and without radiant barriers. Cumulative heat flows predicted by the models were usually within about 5 to 10 percent of measured values. In future phases of the project, the models for attic/radiant barrier performance will be coupled with a whole-house model and further comparisons with experimental data will be made. Following this, the models will be utilized to provide an initial assessment of the energy savings potential of radiant barriers in various configurations and under various climatic conditions. 38 refs., 14 figs., 22 tabs.

  5. Flame radiant image numeralization for pulverized coal combustion in BF raceway

    Institute of Scientific and Technical Information of China (English)

    WEN Liang-ying; OU Yang-qi; BAI Chen-guang; WANG Hua

    2005-01-01

    In order to establish correlativity between pulverized coal combustion in a blast furnace raceway and its radiant image, we investigated the relationships between two dimensional radiant images and three dimensional radiant energy in a blast furnace raceway, focusing on the correlativity of the numerical simulation of combustion processes with the connection of radiant images information and space temperature distribution. We calculated the uneven radiate characteristic parameterby taking radiant images as a kind of radiative boundary for numerical simulation of combustion processes, and put forward a method to examine three-dimensional temperatures distribution in blast furnace raceway by radiant image processing. The numeral temperature fields matching the real combustion can be got by the numeric image processing technique.

  6. Design and Control of Hydronic Radiant Cooling Systems

    Science.gov (United States)

    Feng, Jingjuan

    Improving energy efficiency in the Heating Ventilation and Air conditioning (HVAC) systems in buildings is critical to achieve the energy reduction in the building sector, which consumes 41% of all primary energy produced in the United States, and was responsible for nearly half of U.S. CO2 emissions. Based on a report by the New Building Institute (NBI), when HVAC systems are used, about half of the zero net energy (ZNE) buildings report using a radiant cooling/heating system, often in conjunction with ground source heat pumps. Radiant systems differ from air systems in the main heat transfer mechanism used to remove heat from a space, and in their control characteristics when responding to changes in control signals and room thermal conditions. This dissertation investigates three related design and control topics: cooling load calculations, cooling capacity estimation, and control for the heavyweight radiant systems. These three issues are fundamental to the development of accurate design/modeling tools, relevant performance testing methods, and ultimately the realization of the potential energy benefits of radiant systems. Cooling load calculations are a crucial step in designing any HVAC system. In the current standards, cooling load is defined and calculated independent of HVAC system type. In this dissertation, I present research evidence that sensible zone cooling loads for radiant systems are different from cooling loads for traditional air systems. Energy simulations, in EnergyPlus, and laboratory experiments were conducted to investigate the heat transfer dynamics in spaces conditioned by radiant and air systems. The results show that the magnitude of the cooling load difference between the two systems ranges from 7-85%, and radiant systems remove heat faster than air systems. For the experimental tested conditions, 75-82% of total heat gain was removed by radiant system during the period when the heater (simulating the heat gain) was on, while for air

  7. Validation of CFD simulation for flat plate solar energy collector

    Energy Technology Data Exchange (ETDEWEB)

    Selmi, Mohamed; Al-Khawaja, Mohammed J.; Marafia, Abdulhamid [Department of Mechanical Engineering, University of Qatar, P.O. Box 2713, Doha, State of Qatar (Qatar)

    2008-03-15

    The problem of flat plate solar energy collector with water flow is simulated and analyzed using computational fluid dynamics (CFD) software. The considered case includes the CFD modeling of solar irradiation and the modes of mixed convection and radiation heat transfer between tube surface, glass cover, side walls, and insulating base of the collector as well as the mixed convective heat transfer in the circulating water inside the tube and conduction between the base and tube material. The collector performance, after obtaining 3-D temperature distribution over the volume of the body of the collector, was studied with and without circulating water flow. An experimental model was built and experiments were performed to validate the CFD model. The outlet temperature of water is compared with experimental results and there is a good agreement. (author)

  8. Radiant recuperator modelling and design

    Directory of Open Access Journals (Sweden)

    Knežević Suzana D.

    2017-01-01

    Full Text Available Recuperators are frequently used in glass production and metallurgical processes to preheat combustion air by heat exchange with high temperature flue gases. Mass and energy balances of a 15 m high, concurrent radiant recuperator used in a glass fiber production process are given. The balances are used: for validation of a cell modeling method that predicts the performance of different recuperator designs, and for finding a simple solution to improve the existing recuperator. Three possible solutions are analyzed: to use the existing recuperator as a countercurrent one, to add an extra cylinder over the existing construction, and to make a system that consists of a central pipe and two concentric annular ducts. In the latter, two air streams flow in opposite directions, whereas air in the inner annular passage flows concurrently or countercurrently to flue gases. Compared with the concurrent recuperator, the countercurrent has only one drawback: the interface temperature is higher at the bottom. The advantages are: lower interface temperature at the top where the material is under maximal load, higher efficiency, and smaller pressure drop. Both concurrent and countercurrent double pipe-in-pipe systems are only slightly more efficient than pure concurrent and countercurrent recuperators, respectively. Their advantages are smaller interface temperatures whereas the disadvantages are their costs and pressure drops. To implement these solutions, the average velocities should be: for flue gas around 5 m/s, for air in the first passage less than 2 m/s, and for air in the second passage more than 25 m/s. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. EE 33027

  9. Radiant Professionals Alliance guidelines 2010

    CERN Document Server

    IAPMO

    2010-01-01

    RPA Guidelines for the Design and Installation of Radiant Panel Heating and Snow/Ice Melt Systems. Intended for reference use by code officials, designers and installers. Deals with both hydronic and electric floor, wall and limited ceiling applications. Includes sample schematics and industry recommendations.

  10. Energy flow in plate assembles by hierarchical version of finite element method

    DEFF Research Database (Denmark)

    Wachulec, Marcin; Kirkegaard, Poul Henning

    method has been proposed. In this paper a modified hierarchical version of finite element method is used for modelling of energy flow in plate assembles. The formulation includes description of in-plane forces so that planes lying in different planes can be modelled. Two examples considered are: L......-corner of two rectangular plates an a I-shaped plate girder made of five plates. Energy distribution among plates due to harmonic load is studied and the comparison of performance between the hierarchical and standard finite element formulation is presented....

  11. Thermodynamic energy exchange in a moving plate capacitor.

    Science.gov (United States)

    Davis, B. R.; Abbott, D.; Parrondo, J. M. R.

    2001-09-01

    In this paper we describe an apparent paradox concerning a moving plate capacitor driven by thermal noise from a resistor. The plates are attracted together, but a demon restores the plates of the capacitor to their original position when the voltage across the capacitor is small-hence only small forces are present for the demon to work against. The demon has to work harder than this to avoid the situation of perpetual motion, but the open question is how? This is unsolved, however we explore the concept of a moving plate capacitor by examining the case where it is still excited by thermal noise, but where the restoring force on the capacitor plates is provided by a simple spring rather than some unknown demon. We display simulation results with interesting behavior, particularly where the capacitor plates collide with each other. (c) 2001 American Institute of Physics.

  12. Thermodynamic energy exchange in a moving plate capacitor

    Science.gov (United States)

    Davis, B. R.; Abbott, D.; Parrondo, J. M. R.

    2001-09-01

    In this paper we describe an apparent paradox concerning a moving plate capacitor driven by thermal noise from a resistor. The plates are attracted together, but a demon restores the plates of the capacitor to their original position when the voltage across the capacitor is small—hence only small forces are present for the demon to work against. The demon has to work harder than this to avoid the situation of perpetual motion, but the open question is how? This is unsolved, however we explore the concept of a moving plate capacitor by examining the case where it is still excited by thermal noise, but where the restoring force on the capacitor plates is provided by a simple spring rather than some unknown demon. We display simulation results with interesting behavior, particularly where the capacitor plates collide with each other.

  13. Controlled Production of Sub-Radiant States of a Diatomic Molecule in an Optical Lattice

    CERN Document Server

    Takasu, Yosuke; Takahashi, Yoshiro; Borkowski, Mateusz; Ciuryło, Roman; Julienne, Paul S

    2012-01-01

    We report successful production of sub-radiant states of a two-atom system in a three-dimensional optical lattice starting from doubly occupied sites in a Mott insulator phase of a quantum gas of atomic ytterbium. We can selectively produce either sub-radiant 1g state or super-radiant 0u state by choosing the excitation laser frequency. The inherent weak excitation rate for the sub-radiant 1g state is overcome by the increased atomic density due to the tight-confinement in a three-dimensional optical lattice. Our experimental measurements of binding energies, linewidth, and Zeeman shift confirm observation of sub-radiant levels of the 1g state of the Yb_2 molecule.

  14. An early attempt at an integrated home energy system including solar thermal, ground source heat pump, radiant floor heating, reflective and dynamic insulation and ground-tempered makeup air

    Energy Technology Data Exchange (ETDEWEB)

    White, T.

    2005-07-01

    This paper described an attempt to design and build a comfortable and energy efficient home that integrates solar thermal panels with active and passive features. The exterior walls of the 1700 square foot house were interlocking concrete blocks with radiant floor heating pipes fastened to the outside, which was later covered with rigid insulation and stucco. The active heating system included 4 solar panels and a ground source heat pump with supply lines buried horizontally 5 feet below the surface of the back yard on the south side of the building. The solar panels were used for different purposes in different seasons. The system was monitored for the first winter only. For 4 hours a day in January, 10 per cent more solar energy was measured on the vertical collectors than is available from direct solar insolation at summer solstice. With an outside temperature of -33 degrees C, the solar collectors were capable of maintaining an almost constant core wall temperature of 12 degrees C. The total electricity bill for this all-electric house averaged $60 month during for an entire year, with a single occupant. Despite these results, funding to optimize the control system was not granted. The house was sold at a loss and the heat pump was eventually replaced by a natural gas boiler, which reduced the energy efficiency of the house, but which satisfied the bank who wanted a conventional heating system before approving a mortgage. 2 figs.

  15. Energy flow analysis of out-of-plane vibration in coplanar coupled finite Mindlin plates

    Directory of Open Access Journals (Sweden)

    Park Young-Ho

    2015-01-01

    Full Text Available In this paper, an Energy Flow Analysis (EFA for coplanar coupled Mindlin plates was performed to estimate their dynamic responses at high frequencies. Mindlin plate theory can consider the effects of shear distortion and rotatory inertia, which are very important at high frequencies. For EFA for coplanar coupled Mindlin plates, the wave transmission and reflection relationship for progressing out-of-plane waves (out-of-plane shear wave, bending dominant flexural wave, and shear dominant flexural wave in coplanar coupled Mindlin plates was newly derived. To verify the validity of the EFA results, numerical analyses were performed for various cases where coplanar coupled Mindlin plates are excited by a harmonic point force, and the energy flow solutions for coplanar coupled Mindlin plates were compared with the classical solutions in the various conditions.

  16. Numerical Analysis of a Radiant Heat Flux Calibration System

    Science.gov (United States)

    Jiang, Shanjuan; Horn, Thomas J.; Dhir, V. K.

    1998-01-01

    A radiant heat flux gage calibration system exists in the Flight Loads Laboratory at NASA's Dryden Flight Research Center. This calibration system must be well understood if the heat flux gages calibrated in it are to provide useful data during radiant heating ground tests or flight tests of high speed aerospace vehicles. A part of the calibration system characterization process is to develop a numerical model of the flat plate heater element and heat flux gage, which will help identify errors due to convection, heater element erosion, and other factors. A 2-dimensional mathematical model of the gage-plate system has been developed to simulate the combined problem involving convection, radiation and mass loss by chemical reaction. A fourth order finite difference scheme is used to solve the steady state governing equations and determine the temperature distribution in the gage and plate, incident heat flux on the gage face, and flat plate erosion. Initial gage heat flux predictions from the model are found to be within 17% of experimental results.

  17. Radiant Heating and Cooling Systems. Part one

    DEFF Research Database (Denmark)

    Kim, Kwan Woo; Olesen, Bjarne W.

    2015-01-01

    The use of radiant heating systems has several thousand years of history.1,2 The early stage of radiant system application was for heating purposes, where hot air from flue gas (cooking, fires) was circulated under floors or in walls. After the introduction of plastic piping water-based radiant...... heating and cooling with pipes embedded in room surfaces (floor, wall, and ceiling), the application increased significantly worldwide. Earlier application of radiant heating systems was mainly for residential buildings because of its comfort and free use of floor space without any obstruction from...

  18. PLATE

    DEFF Research Database (Denmark)

    Kling, Joyce; Hjulmand, Lise-Lotte

    2008-01-01

    ’s level of English is sufficient for the increasing number of courses offered in English each semester. This paper addresses these concerns and describes a pilot project initiated in 2003 at CBS to gauge the overall English language proficiency of those teaching content courses in English. Through......Copenhagen Business School (CBS) finds itself needing to address the issue of English-medium instruction for its increasing number of foreign exchange and full degree students. With internationalisation as a main pillar of the institution’s agenda, there are concerns whether the teaching faculty...... the Project in Language Assessment for Teaching in English (PLATE) language professionals from CBS’s Language Center observe teachers and provide feedback using evaluation criteria from the Common European Framework for Reference (CEFR) supplemented by some additional criteria which take the LSP nature...

  19. PLATE

    DEFF Research Database (Denmark)

    Kling, Joyce; Hjulmand, Lise-Lotte

    2008-01-01

    Copenhagen Business School (CBS) finds itself needing to address the issue of English-medium instruction for its increasing number of foreign exchange and full degree students. With internationalisation as a main pillar of the institution’s agenda, there are concerns whether the teaching faculty......’s level of English is sufficient for the increasing number of courses offered in English each semester. This paper addresses these concerns and describes a pilot project initiated in 2003 at CBS to gauge the overall English language proficiency of those teaching content courses in English. Through...... the Project in Language Assessment for Teaching in English (PLATE) language professionals from CBS’s Language Center observe teachers and provide feedback using evaluation criteria from the Common European Framework for Reference (CEFR) supplemented by some additional criteria which take the LSP nature...

  20. Energy flow in plate assembles by hierarchical version of finite element method

    DEFF Research Database (Denmark)

    Wachulec, Marcin; Kirkegaard, Poul Henning

    method has been proposed. In this paper a modified hierarchical version of finite element method is used for modelling of energy flow in plate assembles. The formulation includes description of in-plane forces so that planes lying in different planes can be modelled. Two examples considered are: L......The dynamic analysis of structures in medium and high frequencies are usually focused on frequency and spatial averages of energy of components, and not the displacement/velocity fields. This is especially true for structure-borne noise modelling. For the analysis of complicated structures......-corner of two rectangular plates an a I-shaped plate girder made of five plates. Energy distribution among plates due to harmonic load is studied and the comparison of performance between the hierarchical and standard finite element formulation is presented....

  1. The Estimation of Vibrational Energy of Two Coupled (Welded) Plates Using Statistical Energy Analysis

    OpenAIRE

    2011-01-01

    This paper deals with a method called Statistical Energy Analysis that can be applied to the mechanical and acoustical systems like buildings, bridges and aircrafts …etc. S.E.A as a tool can be applied to the resonant systems in the circumstances of high frequency or/and complex structure». The parameters of S.E.A such as coupling loss factor, internal loss factor, modal density and input power are clarified in this work ; coupled plate sub-systems and explanations are presented for these par...

  2. A non-classical Mindlin plate model incorporating microstructure, surface energy and foundation effects

    Science.gov (United States)

    Gao, X.-L.; Zhang, G. Y.

    2016-07-01

    A non-classical model for a Mindlin plate resting on an elastic foundation is developed in a general form using a modified couple stress theory, a surface elasticity theory and a two-parameter Winkler-Pasternak foundation model. It includes all five kinematic variables possible for a Mindlin plate. The equations of motion and the complete boundary conditions are obtained simultaneously through a variational formulation based on Hamilton's principle, and the microstructure, surface energy and foundation effects are treated in a unified manner. The newly developed model contains one material length-scale parameter to describe the microstructure effect, three surface elastic constants to account for the surface energy effect, and two foundation parameters to capture the foundation effect. The current non-classical plate model reduces to its classical elasticity-based counterpart when the microstructure, surface energy and foundation effects are all suppressed. In addition, the new model includes the Mindlin plate models considering the microstructure dependence or the surface energy effect or the foundation influence alone as special cases, recovers the Kirchhoff plate model incorporating the microstructure, surface energy and foundation effects, and degenerates to the Timoshenko beam model including the microstructure effect. To illustrate the new Mindlin plate model, the static bending and free vibration problems of a simply supported rectangular plate are analytically solved by directly applying the general formulae derived.

  3. Energy trapping of thickness-shear vibration modes of elastic plates with functionally graded materials.

    Science.gov (United States)

    Wang, Ji; Yang, Jiashi; Li, Jiangyu

    2007-03-01

    Energy trapping has important applications in the design of thickness-shear resonators. Considerable efforts have been made for the effective utilization and improvement of energy trapping with variations of plate configurations, such as adding electrodes and contouring. As a new approach in seeking improved energy trapping feature, we analyze thickness-shear vibrations in an elastic plate with functionally graded material (FGM) of in-plane variation of mechanical properties, such as elastic constants and density. A simple and general equation governing the thickness-shear modes is derived from a variational analysis. A plate with piecewise constant material properties is analyzed as an example. It is shown that such a plate can support thickness-shear vibration modes with obvious energy trapping. Bechmann's number for the existence of only one trapped mode also can be determined accordingly.

  4. Effect of Cadmium Plating Thickness on the Charpy Impact Energy of Hydrogen-Charged 4340 Steel

    Science.gov (United States)

    Es-Said, O. S.; Alcisto, J.; Guerra, J.; Jones, E.; Dominguez, A.; Hahn, M.; Ula, N.; Zeng, L.; Ramsey, B.; Mulazimoglu, H.; Li, Yong-Jun; Miller, M.; Alrashid, J.; Papakyriakou, M.; Kalnaus, S.; Lee, E. W.; Frazier, W. E.

    2016-09-01

    Hydrogen was intentionally introduced into ultra-high strength steel by cadmium plating. The purpose was to examine the effect of cadmium plate thickness and hence hydrogen on the impact energy of the steel. The AISI 4340 steel was austenitized at 1000 °C for 1 h, water quenched, and tempered at temperatures between 257 and 593 °C in order to achieve a range of targeted strength levels. The specimens were cadmium plated with 0.00508 mm (0.2 mils), 0.00762 mm (0.3 mils), and 0.0127 mm (0.5 mils). Results demonstrated that the uncharged specimens exhibited higher impact energy values when compared to the plated specimens at all tempering temperatures. The cadmium-plated specimens had very low Charpy impact values irrespective of their ultimate tensile strength values. The model of hydrogen transport by mobile dislocations to the fracture site appears to provide the most suitable explanation of the results.

  5. Advanced radiant combustion system. Final report, September 1989--September 1996

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, J.D.; Carswell, M.G.; Long, F.S.

    1996-09-01

    Results of the Advanced Radiant Combustion System (ARCS) project are presented in this report. This work was performed by Alzeta Corporation as prime contractor under a contract to the U.S. Department of Energy Office of Industrial Technologies as part of a larger DOE program entitled Research Program for Advanced Combustion Systems. The goals of the Alzeta ARCS project were to (a) Improve the high temperature performance characteristics of porous surface ceramic fiber burners, (b) Develop an Advanced Radiant Combustion System (ARCS) that combines combustion controls with an advanced radiant burner, and (c) Demonstrate the advanced burner and controls in an industrial application. Prior to the start of this project, Alzeta had developed and commercialized a porous surface radiant burner, the Pyrocore{trademark} burner. The product had been commercially available for approximately 5 years and had achieved commercial success in a number of applications ranging from small burners for commercial cooking equipment to large burners for low temperature industrial fluid heating applications. The burner was not recommended for use in applications with process temperatures above 1000{degrees}F, which prevented the burner from being used in intermediate to high temperature processes in the chemical and petroleum refining industries. The interest in increasing the maximum use temperature of the burner was motivated in part by a desire to expand the number of applications that could use the Pyrocore product, but also because many of the fluid sensitive heating applications of interest would benefit from the distributed flux characteristic of porous surface burners. Background information on porous surface radiant burners, and a discussion of advantages that would be provided by an improved product, are presented in Section 2.

  6. Thermal stresses and deformations in a plate subject to the action of concentrated energy flows

    Energy Technology Data Exchange (ETDEWEB)

    Rudin, G.I.

    1988-09-01

    A two-dimensional problem concerned with the determination of thermal deformation and the temperature and stress fields in a plate subject to nonhomogeneous heating by a radiative flow of Gaussian type is solved. Cases in which one plate surface is either free or clamped onto a rigid base as well as cases in which the energy source is a laser beam are also considered. Factors such as the thermal diffusivity, specific heat, plate density, linear expansion, shear modulus, optical and energy absorption behavior, and refractivity are incorporated into the solution.

  7. Development of Personalized Radiant Cooling System for an Office Room

    Energy Technology Data Exchange (ETDEWEB)

    Khare, Vaibhav [Malaviya National Institute of Technology (MNIT), Jaipur, India; Sharma, Anuj [Malaviya National Institute of Technology (MNIT), Jaipur, India; Mathur, Jyotirmay [Malaviya National Institute of Technology (MNIT), Jaipur, India; Bhandari, Mahabir S [ORNL

    2015-01-01

    The building industry nowadays is facing two major challenges increased concern for energy reduction and growing need for thermal comfort. These challenges have led many researchers to develop Radiant Cooling Systems that show a large potential for energy savings. This study aims to develop a personalized cooling system using the principle of radiant cooling integrated with conventional all-air system to achieve better thermal environment at the workspace. Personalized conditioning aims to create a microclimatic zone around a single workspace. In this way, the energy is deployed only where it is actually needed, and the individual s needs for thermal comfort are fulfilled. To study the effect of air temperature along with air temperature distribution for workspace, air temperature near the vicinity of the occupant has been obtained as a result of Computational Fluid Dynamics (CFD) simulation using FLUENT. The analysis showed that personalized radiant system improves thermal environment near the workspace and allows all-air systems to work at higher thermostat temperature without compromising the thermal comfort, which in turn reduces its energy consumption.

  8. Energy transfer between a passing vortex ring and a flexible plate in an ideal quiescent fluid

    Energy Technology Data Exchange (ETDEWEB)

    Hu, JiaCheng; Peterson, Sean D., E-mail: peterson@mme.uwaterloo.ca [Department of Mechanical and Mechatronics Engineering, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1 (Canada); Porfiri, Maurizio [Department of Mechanical and Aerospace Engineering, New York University Polytechnic School of Engineering, Brooklyn, New York 11201 (United States)

    2015-09-21

    Recent advancements in highly deformable smart materials have lead to increasing interest in small-scale energy harvesting research for powering low consumption electronic devices. One such recent experimental study by Goushcha et al. explored energy harvesting from a passing vortex ring by a cantilevered smart material plate oriented parallel to and offset from the path of the ring in an otherwise quiescent fluid. The present study focuses on modeling this experimental study using potential flow to facilitate optimization of the energy extraction from the passing ring to raise the energy harvesting potential of the device. The problem is modeled in two-dimensions with the vortex ring represented as a pair of counter-rotating free vortices. Vortex pair parameters are determined to match the convection speed of the ring in the experiments, as well as the imposed pressure loading on the plate. The plate is approximated as a Kirchhoff-Love plate and represented as a finite length vortex sheet in the fluid domain. The analytical model matches experimental measurements, including the tip displacement, the integrated force along the entire plate length as a function of vortex ring position, and the pressure along the plate. The potential flow solution is employed in a parametric study of the governing dimensionless parameters in an effort to guide the selection of plate properties for optimal energy harvesting performance. Results of the study indicate an optimal set of plate properties for a given vortex ring configuration, in which the time-scale of vortex advection matches that of the plate vibration.

  9. High-Frequency Dynamic Analysis of Plates in Thermal Environments Based on Energy Finite Element Method

    Directory of Open Access Journals (Sweden)

    Di Wang

    2015-01-01

    Full Text Available The energy density governing equation to analyze the high-frequency dynamic behavior of plates in thermal environments is derived in this paper, in which the thermal effects are considered to change the membrane stress state and temperature dependent material properties of plates. Then the thermal effects on the energy reflection and transmission coefficients are dealt with hereof. Based on the above, an EFEM (energy finite element method based approximate approach for the energy analysis of coupled plates under nonuniform thermal environments is proposed. The approach could be conducted by three steps: (1 thermal analysis, (2 thermal stress analysis, and (3 forming element matrixes, joint matrixes, and the whole EFEM formulation for the energy analysis. The same mesh model is used for all the three steps. The comparison between EFEM results and classical modal superposition method results of simply supported plates in various uniform thermal environments and coupled plates in nonuniform thermal environments demonstrated that the derived energy governing equation and the proposed approach described well the smooth time- and locally space-averaged energy density. It is found that the distributions and levels of energy density are affected by thermal effects, and the variation trends are related to exciting frequency.

  10. Unusual energy properties of leaky backward Lamb waves in a submerged plate.

    Science.gov (United States)

    Nedospasov, I A; Mozhaev, V G; Kuznetsova, I E

    2017-05-01

    It is found that leaky backward Lamb waves, i.e. waves with negative energy-flux velocity, propagating in a plate submerged in a liquid possess extraordinary energy properties distinguishing them from any other type of waves in isotropic media. Namely, the total time-averaged energy flux along the waveguide axis is equal to zero for these waves due to opposite directions of the longitudinal energy fluxes in the adjacent media. This property gives rise to the fundamental question of how to define and calculate correctly the energy velocity in such an unusual case. The procedure of calculation based on incomplete integration of the energy flux density over the plate thickness alone is applied. The derivative of the angular frequency with respect to the wave vector, usually referred to as the group velocity, happens to be close to the energy velocity defined by this mean in that part of the frequency range where the backward mode exists in the free plate. The existence region of the backward mode is formally increased for the submerged plate in comparison to the free plate as a result of the liquid-induced hybridization of propagating and nonpropagating (evanescent) Lamb modes. It is shown that the Rayleigh's principle (i.e. equipartition of total time-averaged kinetic and potential energies for time-harmonic acoustic fields) is violated due to the leakage of Lamb waves, in spite of considering nondissipative media. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Electron energy dependence of characteristics of fluorescent plates for ultrahigh-voltage electron microscopes.

    Science.gov (United States)

    Nishi, R; Yoshida, K; Takaoka, A; Katsuta, T

    1996-03-01

    The characteristics of fluorescent plates for high energy electron beams (0.5-2.0 MeV) are examined. The thickness and the optical transparency of plates strongly affect the luminous broadening and intensity. The spatial luminous broadening in fluorescent plates is measured and is simply represented by the rise width of a knife edge image. When the thickness is much smaller than the range of incident electrons, the rise width is 1/4-1/5 of the thickness in the case of YAG single crystal plates that are transparent for light, while the rise width is nearly equal to the thickness for the packed P22 powder plates that are opaque for light. To suppress the luminous broadening under 50 microm, the thickness of YAG plates has to be thinner than 250 microm in the energy region around 2 MeV. Under the same condition of the rise width, the luminous intensity of YAG plates is twice as high as that of the P22 plates.

  12. Radiant zone heated particulate filter

    Science.gov (United States)

    Gonze, Eugene V [Pinckney, MI

    2011-12-27

    A system includes a particulate matter (PM) filter including an upstream end for receiving exhaust gas and a downstream end. A radiant zoned heater includes N zones, where N is an integer greater than one, wherein each of the N zones includes M sub-zones, where M is an integer greater than or equal to one. A control module selectively activates at least a selected one of the N zones to initiate regeneration in downstream portions of the PM filter from the one of the N zones, restricts exhaust gas flow in a portion of the PM filter that corresponds to the selected one of the N zones, and deactivates non-selected ones of the N zones.

  13. Variation of strain energy release rate with plate thickness. [fracture mode transition

    Science.gov (United States)

    Sih, G. C.; Hartranft, R. J.

    1973-01-01

    An analytical model of a through-thickness crack in a statically stretched plate is presented in which the crack front stress state is permitted to vary in the direction of the plate thickness. The amplitude or intensity of this stress field can be made nearly constant over a major portion of the interior crack front which is in a state of plane strain. The average amount of work available for extending a small segment of the crack across the thickness is associated with an energy release rate quantity in a manner similar to the two-dimensional Griffith crack model. The theoretically calculated energy release rate is shown to increase with increasing plate thickness, indicating that available work for crack extension is higher in a thicker plate.

  14. Sub-micron alignment for nuclear emulsion plates using low energy electrons caused by radioactive isotopes

    Science.gov (United States)

    Miyamoto, S.; Ariga, A.; Fukuda, T.; Kazuyama, M.; Komatsu, M.; Nakano, T.; Niwa, K.; Sato, O.; Takahashi, S.

    2007-06-01

    Nuclear emulsion plates are employed in three-dimensional charged particle detectors that have sub-micron position resolution over 1 m2 with no dead space and no dead time. These detectors are suitable for the study of short-lived particle decays, and direct detection of neutrino interactions of all flavors. Typically emulsion plates are used in a stacked structure. Precise alignment between plates is required for physics analysis. The most accurate alignment method is to use tracks passing through the emulsion plates. The accuracy is about 0.2 μm. However, in an experiment with low track density alignment accuracy decreases to 20 μm because of plate distortion and it becomes more difficult to perform the analysis. This paper describes a new alignment method between emulsion plates by using trajectories of low energy electrons originating from environmental radioactive isotopes. As a trial emulsion plates were exposed to β-rays and γ-rays from K40. The trajectories which passed through emulsion layers were detected by a fully automated emulsion readout system. Using this method, the alignment between emulsion plates is demonstrated to be sub-micron. This method can be applied to many nuclear emulsion experiments. For example, the location of neutrino interaction vertices in the OPERA experiment can benefit from this new technique.

  15. Evaluating surface energy components of asphalt binders using Wilhelmy Plate and Sessile Drop Techniques

    OpenAIRE

    Bahramian, Anohe

    2012-01-01

    In this Study, the surface energy was investigated for six penetration grade 70/100 bitumen binders. Wilhelmy Plate and the Sessile Drop were used to determine the contact angles. The purpose of this study was to compare the Wilhelmy Plate method with the Sessile Drop method, and to compare the significance of Owens-Wendt model with the significance of Acid Base model by correlating surface energy components. Better R2 –values were found for surface energy components by using the Owens-Wendt ...

  16. Radiant cooling in US office buildings: Towards eliminating the perception of climate-imposed barriers

    Energy Technology Data Exchange (ETDEWEB)

    Stetiu, Corina [Univ. of California, Berkeley, CA (United States)

    1998-01-01

    Much attention is being given to improving the efficiency of air-conditioning systems through the promotion of more efficient cooling technologies. One such alternative, radiant cooling, is the subject of this thesis. Performance information from Western European buildings equipped with radiant cooling systems indicates that these systems not only reduce the building energy consumption but also provide additional economic and comfort-related benefits. Their potential in other markets such as the US has been largely overlooked due to lack of practical demonstration, and to the absence of simulation tools capable of predicting system performance in different climates. This thesis describes the development of RADCOOL, a simulation tool that models thermal and moisture-related effects in spaces equipped with radiant cooling systems. The thesis then conducts the first in-depth investigation of the climate-related aspects of the performance of radiant cooling systems in office buildings. The results of the investigation show that a building equipped with a radiant cooling system can be operated in any US climate with small risk of condensation. For the office space examined in the thesis, employing a radiant cooling system instead of a traditional all-air system can save on average 30% of the energy consumption and 27% of the peak power demand due to space conditioning. The savings potential is climate-dependent, and is larger in retrofitted buildings than in new construction. This thesis demonstrates the high performance potential of radiant cooling systems across a broad range of US climates. It further discusses the economics governing the US air-conditioning market and identifies the type of policy interventions and other measures that could encourage the adoption of radiant cooling in this market.

  17. Hadron energy resolution as a function of iron plate thickness at ICAL

    CERN Document Server

    Mohan, Lakshmi S; Devi, Moon Moon; Kaur, Daljeet; Choubey, Sandhya; Dighe, Amol; Indumathi, D; Murthy, M V N; Naimuddin, Md

    2014-01-01

    We report on a detailed study of the hadron energy resolution as a function of the thickness of the absorber plates for the proposed Iron Calorimeter (ICAL) detector at the India-based Neutrino Observatory (INO). We compare the hadron resolutions obtained with absorber thicknesses in the range 1.5 -- 8 cm for neutrino interactions in the energy range 2 -- 15 GeV, which is relevant to hadron production in atmospheric neutrino interactions. We find that at lower energies, the thickness dependence of energy resolution is steeper than at higher energies, however there is a constant contribution that dominates at the lower thicknesses discussed in this paper. As a result, the gain in hadron energy resolution with decreasing plate thickness is marginal. We present the results in the form of fits to a function with energy-dependent exponent.

  18. Effect of End Plates on the Performence of a Wells Turbine for Wave Energy Conversion

    Institute of Scientific and Technical Information of China (English)

    Manabu Takao; Toshiaki Setoguchi; Yoichi Kinoue; Kenji Kaneko

    2006-01-01

    In order to improve the performance of the Wells turbine for wave energy conversion,the effect of end plates on the turbine characteristics has been investigated experimentally by model testing under steady flow conditions.The end plate attached to the tip of the original rotor blade is slightly larger than the original blade profile.The characteristics of the Wells turbine with end plates have been compared with those of the original Wells turbine,i.e.,the turbine without end plate.As a result,it has been concluded that the characteristics of the Wells turbine with end plates are superior to those of the original Wells turbine and the characteristics are dependent on the size and position of end plate.Furthermore,the effect of annular plate on the turbine performance,which encircles the turbine and is attached to the tip,was investigated as an additional experiment.However,its device was not effective in improving the turbine characteristics.

  19. Factors Affecting Energy Absorption of a Plate during Shock Wave Impact Using a Damage Material Model

    Science.gov (United States)

    2010-08-07

    array according to the Taguchi method . An orthogonal array is generated to govern the arrangement of the five parameters in the 16 calculations... Taguchi method described in Chapter 3. Energy absorption of the plate was the response investigated and was calculated as strain energy at first... Taguchi method . Table 6.1 shows the energy absorbed by first element failure for each of the 16 simulations. Those results were placed in the

  20. Characteristic properties of the Casimir free energy for metal films deposited on metallic plates

    Science.gov (United States)

    Klimchitskaya, G. L.; Mostepanenko, V. M.

    2016-04-01

    The Casimir free energy and pressure of thin metal films deposited on metallic plates are considered using the Lifshitz theory and the Drude and plasma model approaches to the role of conduction electrons. The bound electrons are taken into account by using the complete optical data of film and plate metals. It is shown that for films of several tens of nanometers thickness the Casimir free energy and pressure calculated using these approaches differ by hundreds and thousands percent and can be easily discriminated experimentally. According to our results, the free energy of a metal film does not vanish in the limiting case of ideal metal if the Drude model approach is used in contradiction with the fact that the fluctuating field cannot penetrate in its interior. Numerical computations of the Casimir free energy and pressure of Ag and Au films deposited on Cu and Al plates have been performed using both theoretical approaches. It is shown that the free energy of a film can be both negative and positive depending on the metals used. For a Au film on a Ag plate and vice versa the Casimir energy of a film changes its sign with increasing film thickness. Applications of the obtained results for resolving the Casimir puzzle and the problem of stability of thin films are discussed.

  1. Heat transfer and energy analysis of a solar air collector with smooth plate

    Science.gov (United States)

    Chabane, Foued; Moummi, Noureddine

    2014-04-01

    The heat transfer and thermal performance of a single pass solar air heater a smooth plate was investigated experimentally. In the present paper, energy and heat transfer analysis of a solar air collector with smooth plate, this technique is used to determine the optimal thermal performance of flat plate solar air heater by considering the different system and operating parameters to obtain maximum thermal performance. Thermal performance is obtained for different mass flow rate varying in the array 0.0108-0.0202 kg/s with five values, solar intensity; tilt angle and ambient temperature. We discuss the thermal behavior of this type of collector with new design and with my proper construction. An experimental study was carried out on a prototype installed on the experimental tests platform within the University of Biskra in the Algeria. The effects of air mass flow rate, emissivity of channel plates and wind heat transfer coefficient on the accuracy of the criterion are also investigated.

  2. On a consistent finite-strain plate theory based on 3-D energy principle

    CERN Document Server

    Dai, Hui-Hui

    2014-01-01

    This paper derives a finite-strain plate theory consistent with the principle of stationary three-dimensional (3-D) potential energy under general loadings with a third-order error. Staring from the 3-D nonlinear elasticity (with both geometrical and material nonlinearity) and by a series expansion, we deduce a vector plate equation with three unknowns, which exhibits the local force-balance structure. The success relies on using the 3-D field equations and bottom traction condition to derive exact recursion relations for the coefficients. Associated weak formulations are considered, leading to a 2-D virtual work principle. An alternative approach based on a 2-D truncated energy is also provided, which is less consistent than the first plate theory but has the advantage of the existence of a 2-D energy function. As an example, we consider the pure bending problem of a hyperelastic block. The comparison between the analytical plate solution and available exact one shows that the plate theory gives second-order...

  3. Ten questions about radiant heating and cooling systems

    DEFF Research Database (Denmark)

    Rhee, Kyu-Nam; Olesen, Bjarne W.; Kim, Kwang Woo

    2017-01-01

    Radiant heating and cooling (RHC) systems are being increasingly applied not only in residential but also in non-residential buildings such as commercial buildings, education facilities, and even large scale buildings such as airport terminals. Furthermore, with the combined ventilation system used...... studies on RHC systems in terms of comfort, heat transfer analysis, energy simulation, control strategy, system configurations and so on. Many studies have demonstrated that the RHC system is a good solution to improve indoor environmental quality while reducing building energy consumption for heating...

  4. Ultrasonic seam welding technologies of copper plate and tube for collecting solar energy

    Institute of Scientific and Technical Information of China (English)

    汤勇; 万珍平; 刘亚俊; 刘树道

    2003-01-01

    The ultrasonic welding is applied more and more extensively due to its advantages such as environmental protection, cleaning and energy saving. By researching the mechanism on ultrasonic seam welding of copper plates and tubes for collecting solar energy, it is put forward that the ultrasonic metal welding process can be divided into two stages, and two factors make functions jointly to join the welded metal specimens. In order to successfully join the welding, three basic conditions must be satisfied, that is, there should be high frequency friction vibration in the contact interface; pressure must be imposed on the plate specimen during friction vibration; the time of friction vibration and pressure imposed should be proper. Furthermore, how to select the hardness of copper plate and tube and ultrasonic seam welding parameters is analyzed by experiments.

  5. Modelling Bending Wave Transmission across Coupled Plate Systems Comprising Periodic Ribbed Plates in the Low-, Mid-, and High-Frequency Ranges Using Forms of Statistical Energy Analysis

    Directory of Open Access Journals (Sweden)

    Jianfei Yin

    2015-01-01

    Full Text Available Prediction of bending wave transmission across systems of coupled plates which incorporate periodic ribbed plates is considered using Statistical Energy Analysis (SEA in the low- and mid-frequency ranges and Advanced SEA (ASEA in the high-frequency range. This paper investigates the crossover from prediction with SEA to ASEA through comparison with Finite Element Methods. Results from L-junctions confirm that this crossover occurs near the frequency band containing the fundamental bending mode of the individual bays on the ribbed plate when ribs are parallel to the junction line. Below this frequency band, SEA models treating each periodic ribbed plate as a single subsystem were shown to be appropriate. Above this frequency band, large reductions occur in the vibration level when propagation takes place across successive bays on ribbed plates when the ribs are parallel to the junction. This is due to spatial filtering; hence it is necessary to use ASEA which can incorporate indirect coupling associated with this transmission mechanism. A system of three coupled plates was also modelled which introduced flanking transmission. The results show that a wide frequency range can be covered by using both SEA and ASEA for systems of coupled plates where some or all of the plates are periodic ribbed plates.

  6. Improvement of flat plate collectors for solar energy conversion

    Science.gov (United States)

    Boeck, H.; Hallermayer, R.; Schoelkopf, W.; Sizman, R.

    1984-03-01

    Selective absorption for thermal conversion of radiative energy was investigated. Improvement and operation of various measuring devices for absorption and emission are presented. Selective coatings were produced by vapor deposition and galvanic treatment. Calculations of the transmittance of turbular collector fields are presented. Operational Characteristics of Collector were examined. A collector test field with simultaneous recording of data from 24 collectors or uncovered absorbers was built and connected to a high performance microprocessor system. The transient behavior of collectors by variation of the irradiation and the collector inlet temperature were investigated. A mechanism for stratification of hot water of fluctuating inlet temperature in a storage tank was studied. The operating conditions of a heat pump installed in the collector test plant are investigated. A large domestic hot water system is equipped with temperature sensors and flowmeters for computer recording.

  7. Vortex Formation, Shedding and Energy Harvesting from a Cyber-Physical Pitching Flat Plate

    Science.gov (United States)

    Onoue, Kyohei; Breuer, Kenneth

    2014-11-01

    We examine the dynamics and energy harvesting capabilities of an elastically mounted flat plate undergoing large amplitude limit cycle oscillations in a uniform flow. All experiments are performed using a cyber-physical system, wherein the structural inertia, stiffness and damping are numerically simulated using a position-following feedback algorithm. The cyber-physical system also allows for implementation of nonlinear spring and damping coefficients, which control the plate dynamics and subsequent energy harvesting characteristics. Analysis of the plate kinematics and the fluid flow over the plate and in the wake (measured using PIV) are used to understand the interplay between structural motion and vortex formation at the sharp leading and trailing edges of the plate. By varying the structural properties of the system we systematically analyze the formation, strength, stability and separation of the leading edge vortex, as well as the dependence on kinematic parameters and Reynolds number. Connections to previous results on vortex formation time and bluff body aerodynamics are discussed. This research is funded by the Air Force Office of Scientific Research (AFOSR).

  8. Angular Distribution Models for Top-of-Atmosphere Radiative Flux Estimation from the Clouds and the Earth's Radiant Energy System Instrument on the Tropical Rainfall Measuring Mission Satellite. Part II; Validation

    Science.gov (United States)

    Loeb, N. G.; Loukachine, K.; Wielicki, B. A.; Young, D. F.

    2003-01-01

    Top-of-atmosphere (TOA) radiative fluxes from the Clouds and the Earth s Radiant Energy System (CERES) are estimated from empirical angular distribution models (ADMs) that convert instantaneous radiance measurements to TOA fluxes. This paper evaluates the accuracy of CERES TOA fluxes obtained from a new set of ADMs developed for the CERES instrument onboard the Tropical Rainfall Measuring Mission (TRMM). The uncertainty in regional monthly mean reflected shortwave (SW) and emitted longwave (LW) TOA fluxes is less than 0.5 W/sq m, based on comparisons with TOA fluxes evaluated by direct integration of the measured radiances. When stratified by viewing geometry, TOA fluxes from different angles are consistent to within 2% in the SW and 0.7% (or 2 W/sq m) in the LW. In contrast, TOA fluxes based on ADMs from the Earth Radiation Budget Experiment (ERBE) applied to the same CERES radiance measurements show a 10% relative increase with viewing zenith angle in the SW and a 3.5% (9 W/sq m) decrease with viewing zenith angle in the LW. Based on multiangle CERES radiance measurements, 18 regional instantaneous TOA flux errors from the new CERES ADMs are estimated to be 10 W/sq m in the SW and, 3.5 W/sq m in the LW. The errors show little or no dependence on cloud phase, cloud optical depth, and cloud infrared emissivity. An analysis of cloud radiative forcing (CRF) sensitivity to differences between ERBE and CERES TRMM ADMs, scene identification, and directional models of albedo as a function of solar zenith angle shows that ADM and clear-sky scene identification differences can lead to an 8 W/sq m root-mean-square (rms) difference in 18 daily mean SW CRF and a 4 W/sq m rms difference in LW CRF. In contrast, monthly mean SW and LW CRF differences reach 3 W/sq m. CRF is found to be relatively insensitive to differences between the ERBE and CERES TRMM directional models.

  9. Experimental Study of Isothermal Plate Uniformity for Blood Warmer Development using Geothermal Energy

    Science.gov (United States)

    Hendrarsakti, J.; Ichsan, Y.

    2016-09-01

    This research was conducted to assess the direct use of geothermal energy for blood warmer. The heating plate was made form aluminium plates with dimensions of 100 x 200 mm and then fed from the hot water heater. Tests were conducted in the laboratory where geothermal source water is replaced with the heat generated from the heater. The hot water from the heater in the temperature range 55°C - 60°C flowed into vertical chamber. Setting the temperature of the hot water heater is done by changing the flow of hot water coming out of the heater. Results showed that the value of a standard deviation of plate temperature was about 0.42 °C, so it can be said isothermal accordance with design requirement and objective. The test data used for the analysis of the manufacture of the heating plate in the blood warmer to regulate the discharge of hot water at intervals of 21.47 mL/s to 24.8 mL/s to obtain a temperature of 37.20 °C - 40.15 °C. Geothermal energy has the potential for blood warmer because blood warmer is part of the energy cascade in a temperature range of 40°C to 60°C

  10. Development of scintillator plates with high energy resolution for alpha particles made of GPS scintillator grains

    Science.gov (United States)

    Shimaoka, Takehiro; Kaneko, Junichi H.; Izaki, Kenji; Tsubota, Youichi; Higuchi, Mikio; Nishiyama, Shusuke

    2014-01-01

    A scintillator plate with high energy resolution was developed to produce an alpha particle monitor used in nuclear fuel reprocessing plants and mixed plutonium-uranium oxide (MOX) fuel plants. Grains of a Gd2Si2O7 (GPS) scintillator of several 10 to 550 μm were fixed on a glass substrate and were then mechanically polished. By increasing the size of scintillator grains and removing fine powders, the collected light yield and energy resolution for alpha particles were drastically improved. Energy resolution of 9.3% was achieved using average grain size of 91 μm. Furthermore, the ratios between counts in a peak and total counts were improved by more than 60% by the further increase of grain size and adoption of mechanically polished surfaces on both sides. Beta and gamma ray influences were suppressed sufficiently by the thin 100 μm scintillator plates.

  11. Bicolumnar 90-90 plating of low-energy distal humeral fractures in the elderly patient.

    Science.gov (United States)

    Leigey, Daniel F; Farrell, Dana J; Siska, Peter A; Tarkin, Ivan S

    2014-09-01

    Fragility fractures of the distal humerus in elderly patients, especially the low transcondylar fracture pattern, can be difficult to optimally manage. Although the fractures are typically low energy resulting in either extra-articular or simple intra-articular patterns, gaining fixation into the distal fragments can be difficult with open reduction internal fixation (ORIF) using traditional 90-90 or parallel plating techniques. Anatomy preserving reconstruction with ORIF is preferred over total elbow arthroplasty (TEA) if possible. In this study, 15 patients were managed with a bicolumnar 90-90 plating construct as a novel method of enhancing distal fixation in these fractures. Fourteen patients went on to radiographic union at an average of 77 days after surgery with an average arc of motion of 105°. One patient was lost to follow-up. Bicolumnar 90-90 plating of distal humerus fractures in elderly patients may represent a viable alternative to traditional ORIF or TEA.

  12. Characterization and Scaling of Heave Plates for Ocean Wave Energy Converters

    Science.gov (United States)

    Rosenberg, Brian; Mundon, Timothy

    2016-11-01

    Ocean waves present a tremendous, untapped source of renewable energy, capable of providing half of global electricity demand by 2040. Devices developed to extract this energy are known as wave energy converters (WECs) and encompass a wide range of designs. A somewhat common archetype is a two-body point-absorber, in which a surface float reacts against a submerged "heave" plate to extract energy. Newer WEC's are using increasingly complex geometries for the submerged plate and an emerging challenge in creating low-order models lies in accurately determining the hydrodynamic coefficients (added mass and drag) in the corresponding oscillatory flow regime. Here we present experiments in which a laboratory-scale heave plate is sinusoidally forced in translation (heave) and rotation (pitch) to characterize the hydrodynamic coefficients as functions of the two governing nondimensional parameters, Keulegan-Carpenter number (amplitude) and Reynolds number. Comparisons against CFD simulations are offered. As laboratory-scale physical model tests remain the standard for testing wave energy devices, effects and implications of scaling (with respect to a full-scale device) are also investigated.

  13. Hydronic radiant cooling: Overview and preliminary performance assessment

    Energy Technology Data Exchange (ETDEWEB)

    Feustel, H.E.

    1993-05-01

    A significant amount of electrical energy used to cool non-residential buildings is drawn by the fans used to transport the cool air through the thermal distribution system. Hydronic systems reduce the amount of air transported through the building by separating ventilation and thermal conditioning. Due to the physical properties of water, hydronic distribution systems can transport a given amount of thermal energy using less than 5% of the otherwise necessary fan energy. This savings alone significantly reduces the energy consumption and especially the peak power requirement This survey clearly shows advantages for radiant cooling in combination with hydronic thermal distribution systems in comparison with the All-Air Systems commonly used in California. The report describes a literature survey on the system`s development, thermal comfort issues, and cooling performance. The cooling power potential and the cooling power requirement are investigated for several California climates. Peak-power requirement is compared for hydronic radiant cooling and conventional All-Air-Systems.

  14. Hydronic radiant cooling: Overview and preliminary performance assessment

    Energy Technology Data Exchange (ETDEWEB)

    Feustel, H.E.

    1993-05-01

    A significant amount of electrical energy used to cool non-residential buildings is drawn by the fans used to transport the cool air through the thermal distribution system. Hydronic systems reduce the amount of air transported through the building by separating ventilation and thermal conditioning. Due to the physical properties of water, hydronic distribution systems can transport a given amount of thermal energy using less than 5% of the otherwise necessary fan energy. This savings alone significantly reduces the energy consumption and especially the peak power requirement This survey clearly shows advantages for radiant cooling in combination with hydronic thermal distribution systems in comparison with the All-Air Systems commonly used in California. The report describes a literature survey on the system's development, thermal comfort issues, and cooling performance. The cooling power potential and the cooling power requirement are investigated for several California climates. Peak-power requirement is compared for hydronic radiant cooling and conventional All-Air-Systems.

  15. Improved thermal performance of a hydronic radiant panel heating system by the optimization of tube shapes

    Institute of Scientific and Technical Information of China (English)

    Young T. CHAE; Kwang Ho LEE; Jae Sung PARK

    2011-01-01

    The thermal performance enhancement of the hydronic radiant floor heating system by tube shape refinements is investigated in this paper. Both analytical and detailed numerical modelings are carried out to predict the performance of the radiant system. While the simple analytical model briefly investigates the possibility of the effect of the tube shape improvement with the parametric analysis, the commercial computational fluid dynamics (CFD) code (Ansys/CFX) is used to perform the detailed 3D analysis under different tube shape conditions. The fin thickness, the number of fins, and the tube thermal conductivity turn out to have significant effects on the radiant system performance. The potential energy saving impacts of the tube shape refinements are also discussed. The tube shape improvement turns out to increase the floor surface temperature and to decrease the hot water temperature drop across the system, resulting in heating energy savings.

  16. Energy harvesting in pavement from passing vehicles with piezoelectric composite plate for ice melting

    Science.gov (United States)

    Faisal, Farjana; Wu, Nan; Kapoor, Kartik

    2016-04-01

    An energy harvester in the road pavement made from a piezoelectric composite plate is designed and studied to collect energy from the passing vehicles for the ice melting aim. Piezoelectric material has the ability to produce electric charge on its surface when strain takes place due to any external loading. Based on this property, a rectangular composite plate harvester is developed consisting of piezoelectric material as the energy generation coating layer and A514 steel as the substrate layer to realize the energy harvesting process from the variable pressure generated in the road pavement by passing vehicles. Based on Westergaards stress model, a numerical model is developed to calculate the three dimensional stress distribution in the pavement. Numerical simulations are conducted to study the optimization of various parameters of the harvester, such as depth of the harvester in the pavement, length and width as well as thicknesses of piezoelectric layer and the substrate. By taking in to consideration the maximum stress that can be sustained by both of the piezoelectric material and also the substrate material, an optimum design of the piezoelectric couple composite plate energy harvester is suggested. It is seen that the maximum output power, which can be generated by a single patch of 0.2m*0.2m*0.0026m dimension with a vehicle passing at 22.2 m/s, can reach up to 23.36 W. With the well-designed pavement energy harvesters, it is feasible to collect enough energy to rise the temperature of the ice with the thickness of 1cm covering a 5m width road by 20 degree Celsius within 2.5 hours. This technique can be applied to melt the ice on the roads and bridges especially in cold countries.

  17. Waves on Thin Plates: A New (Energy Based) Method on Localization

    Science.gov (United States)

    Turkaya, Semih; Toussaint, Renaud; Kvalheim Eriksen, Fredrik; Lengliné, Olivier; Daniel, Guillaume; Grude Flekkøy, Eirik; Jørgen Måløy, Knut

    2016-04-01

    Noisy acoustic signal localization is a difficult problem having a wide range of application. We propose a new localization method applicable for thin plates which is based on energy amplitude attenuation and inversed source amplitude comparison. This inversion is tested on synthetic data using a direct model of Lamb wave propagation and on experimental dataset (recorded with 4 Brüel & Kjær Type 4374 miniature piezoelectric shock accelerometers, 1 - 26 kHz frequency range). We compare the performance of this technique with classical source localization algorithms, arrival time localization, time reversal localization, localization based on energy amplitude. The experimental setup consist of a glass / plexiglass plate having dimensions of 80 cm x 40 cm x 1 cm equipped with four accelerometers and an acquisition card. Signals are generated using a steel, glass or polyamide ball (having different sizes) quasi perpendicular hit (from a height of 2-3 cm) on the plate. Signals are captured by sensors placed on the plate on different locations. We measure and compare the accuracy of these techniques as function of sampling rate, dynamic range, array geometry, signal to noise ratio and computational time. We show that this new technique, which is very versatile, works better than conventional techniques over a range of sampling rates 8 kHz - 1 MHz. It is possible to have a decent resolution (3cm mean error) using a very cheap equipment set. The numerical simulations allow us to track the contributions of different error sources in different methods. The effect of the reflections is also included in our simulation by using the imaginary sources outside the plate boundaries. This proposed method can easily be extended for applications in three dimensional environments, to monitor industrial activities (e.g boreholes drilling/production activities) or natural brittle systems (e.g earthquakes, volcanoes, avalanches).

  18. A multigap resistive plate chamber array for the Extreme Energy Events project

    Science.gov (United States)

    De Gruttola, D.; Abbrescia, M.; Agocs, A.; Aiola, S.; Antolini, R.; Avanzini, C.; Baldini Ferroli, R.; Bencivenni, G.; Bossini, E.; Bressan, E.; Chiavassa, A.; Cicalò, C.; Cifarelli, L.; Coccia, E.; De Pasquale, S.; Di Giovanni, A.; D'Incecco, M.; Dreucci, M.; Fabbri, F. L.; Frolov, V.; Garbini, M.; Gemme, G.; Gnesi, I.; Gustavino, C.; Hatzifotiadou, D.; La Rocca, P.; Li, S.; Librizzi, F.; Maggiora, A.; Massai, M.; Miozzi, S.; Panareo, M.; Paoletti, R.; Perasso, L.; Pilo, F.; Piragino, G.; Regano, A.; Riggi, F.; Righini, G. C.; Sartorelli, G.; Scapparone, E.; Scribano, A.; Selvi, M.; Serci, S.; Siddi, E.; Spandre, G.; Squarcia, S.; Taiuti, M.; Tosello, F.; Votano, L.; Williams, M. C. S.; Yanez, G.; Zichichi, A.; Zouyevski, R.

    2014-10-01

    The Extreme Energy Events (EEE) Project is a Centro Fermi - CERN - INFN - MIUR Collaboration Project for the study of extremely high energy cosmic rays, which exploits the Multigap Resistive Plate Chamber (MRPC) technology. The excellent time resolution and good tracking capability of this kind of detector allows us to study Extensive Air Showers (EAS) with an array of MRPC telescopes distributed across the Italian territory. Each telescope is installed in a high school, with the further goal to introduce students to particle and astroparticle Physics. The status of the experiment and the results obtained are reported.

  19. Theoretical Research of Radiant Intensity of Roller Hearth Furnace%辊底式热处理炉辐射强度的理论研究

    Institute of Scientific and Technical Information of China (English)

    吴永红

    2012-01-01

    The heat transfer mathematical model between the furnace wall, the radiant tube and the plate (roller) of the roller hearth furnace for steel heat treatment was established to solve the design problem. The influences of radiant intensity of radiant tube on the furnace temperature rate and the radiant tube surface temperature were studied. The value range of the radiant tube radiant intensity of roller hearth furnace was calculated and determined in theory, and the important significance of the radiant intensity for the design of the roller hearth furnace was revealed. Furthermore, through integrating theory with practice, the study results were further confirmed.%针对钢板热处理用辊底式热处理炉的设计,建立了炉墙、辐射管以及炉辊(钢板)之间的传热数学模型,研究了辐射管的辐射强度对炉子升温速度以及辐射管表面温度的影响.从理论上计算并确定了辊底式热处理炉辐射管辐射强度的取值范围,揭示了辐射强度对辊底式热处理炉设计的重要意义,并且通过理论与实际相结合,对研究结果进行了进一步的验证.

  20. Improved radiant burner material. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Milewski, J.V.; Shoultz, R.A.; Bourque, M.M.; Milewski, E.B. [and others

    1998-01-01

    Under DOE/ERIP funds were made available to Superkinetic, Inc. for the development of an improved radiant burner material. Three single crystal ceramic fibers were produced and two fiber materials were made into felt for testing as radiant burner screens. The materials were alpha alumina and alpha silicon nitride. These fibers were bonded with a high temperature ceramic and made into a structurally sound trusswork like screen composed of million psi fiber members. These screens were about 5% solid for 95 porosity as needed to permit the flow of combustable natural gas and air mixture. Combustion test proved that they performed very satisfactory and better than the current state of art screen and showed no visable degrade after testing. It is recommended that more time and money be put into expanding this technology and test these new materials for their maximum temperature and durability for production applications that require better burner material.

  1. The influence of circuit inductance on the energy characteristics of electric discharge and deformation of plates in water

    Science.gov (United States)

    Kosenkov, V. M.; Bychkov, V. M.

    2017-08-01

    We have experimentally studied the influence of discharge-circuit inductance on the efficiency of conversion of energy stored in a capacitor bank, evolved in the electric-discharge channel in water, and spent for the resulting plastic deformation of plates. It is established for the first time that a growth in inductance of the discharge circuit produces a positive effect on the deformation of plates by increasing the amount of energy spent in this process.

  2. Calibrating image plate sensitivity in the 700 to 5000 eV spectral energy range

    Science.gov (United States)

    Haugh, Michael J.; Lee, Joshua; Romano, Edward; Schneider, Marilyn

    2013-09-01

    This paper describes a method to calibrate image plate sensitivity for use in the low energy spectral range. Image plates, also known as photostimulable luminescence (PSL) detectors, have often proved to be a valuable tool as a detector for plasma physics studies. Their advantages of large dynamic range, high stopping power, and resistance to neutron damage sometimes outweigh the problems of limited resolution and the remote processing required. The neutron damage resistance is required when the X-ray source is producing a high neutron flux. The Static X-ray Imager (SXI) is a key diagnostic on the National Ignition Facility (NIF) target chamber at LLNL for use in determining the symmetry of the laser beams. The SXI is essential to proper interpretation of the data from the Dante diagnostic to determine the X-ray radiation temperature. It is comprised of two diagnostics located at the top and the bottom of the target chamber. The usual detector is a large array CCD camera. For shots giving high yields of neutrons, the camera would not only be blinded by the neutrons, it would be damaged. To get around this problem, an image plate (IP) is used as the detector. The NIF application covers the energy range from 700 to 5000 eV. The type of image plates typically used for plasma physics are the Fuji BAS-MS, BAS-SR, and BAS-TR models. All models consist of an X-ray sensitive material made of BaF(Br,I):Eu2+ embedded in a plastic binder. X-rays incident on the phosphor ionize the Eu 2+ producing Eu3+ and free electrons that are trapped in lattice defects (F-centers) produced by the absence of halogen ions in the BaF2 crystal. An image plate readout scanner irradiates the IP with a red laser causing reduction of the Eu3+ and emission of a blue photon. The photon is collected using a photomultiplier and digitized to make an electronic image. Image plates are cleared of all F-centers by putting them under a bright light for about 10 minutes. They are then ready for producing a

  3. Coupling Motion and Energy Harvesting of Two Side-by-Side Flexible Plates in a 3D Uniform Flow

    Directory of Open Access Journals (Sweden)

    Dibo Dong

    2016-05-01

    Full Text Available The fluid-structure interaction problems of two side-by-side flexible plates with a finite aspect ratio in a three-dimensional (3D uniform flow are numerically studied. The plates’ motions are entirely passive under the force of surrounding fluid. By changing the aspect ratio and transverse distance, the coupling motions, drag force and energy capture performance are analyzed. The mechanisms underlying the plates’ motion and flow characteristics are discussed systematically. The adopted algorithm is verified and validated by the simulation of flow past a square flexible plate. The results show that the plate’s passive flapping behavior contains transverse and spanwise deformation, and the flapping amplitude is proportional to the aspect ratio. In the side-by-side configuration, three distinct coupling modes of the plates’ motion are identified, including single-plate mode, symmetrical flapping mode and decoupled mode. The plate with a lower aspect ratio may suffer less drag force and capture less bending energy than in the isolated situation. The optimized selection for obtaining higher energy conversion efficiency is the plate flapping in single-plate mode, especially the plate with a higher aspect ratio. The findings of this work provide several new physical insights into the understanding of fish schooling and are expected to inspire the developments of underwater robots or energy harvesters.

  4. TELBE - the super-radiant THz facility at ELBE

    Energy Technology Data Exchange (ETDEWEB)

    Green, Bertram; Kovalev, Sergei; Hauser, Jens; Kuntzsch, Michael; Schneider, Harald; Winnerl, Stephan; Seidel, Wolfgang; Zvyagin, Sergei; Lehnert, Ulf; Helm, Manfred; Michel, Peter; Gensch, Michael [Helmholtz-Zentrum Dresden-Rossendorf (Germany); Al-Shemmary, Alaa; Radu, Ilie; Stojanovic, Nikola; Cavalleri, Andrea [Deutsches Elektronen-Synchrotron (Germany); Wall, Simon [FHI Berlin (Germany); Eng, Lukas M. [Technische Universitaet Dresden (Germany); Heberle, Joachim [FU Berlin (Germany)

    2013-07-01

    It has been shown recently that relativistic electron bunches can be utilized for the generation of super-radiant coherent THz radiation by one single pass through an undulator, bending magnet, or CDR/CTR screens. However, the high THz fields have all been achieved at large accelerators that allow for high electron beam energies. A crucially important research topic for the next years at the HZDR is therefore to investigate whether an equally fine control over highly charged electron bunch form can be routinely achieved in a low electron beam energy accelerator like ELBE. If successful this development would allow the generation of high field THz fields by linear accelerators at considerably reduced cost. Given stable operation can be provided, TELBE, could also become a world-wide unique research facility for high field THz science. The current status and an outlook on future developments are presented.

  5. Boundary Layer of Photon Absorption Applied to Heterogeneous Photocatalytic Solar Flat Plate Reactor Design

    Directory of Open Access Journals (Sweden)

    Héctor L. Otálvaro-Marín

    2014-01-01

    Full Text Available This study provides information to design heterogeneous photocatalytic solar reactors with flat plate geometry used in treatment of effluents and conversion of biomass to hydrogen. The concept of boundary layer of photon absorption taking into account the efficient absorption of radiant energy was introduced; this concept can be understood as the reactor thickness measured from the irradiated surface where 99% of total energy is absorbed. Its thickness and the volumetric rate of photons absorption (VRPA were used as design parameters to determine (i reactor thickness, (ii maximum absorbed radiant energy, and (iii the optimal catalyst concentration. Six different commercial brands of titanium dioxide were studied: Evonik-Degussa P-25, Aldrich, Merck, Hombikat, Fluka, and Fisher. The local volumetric rate of photon absorption (LVRPA inside the reactor was described using six-flux absorption-scattering model (SFM applied to solar radiation. The radiation field and the boundary layer thickness of photon absorption were simulated with absorption and dispersion effects of catalysts in water at different catalyst loadings. The relationship between catalyst loading and reactor thickness that maximizes the absorption of radiant energy was obtained for each catalyst by apparent optical thickness. The optimum concentration of photocatalyst Degussa P-25 was 0.2 g/l in 0.86 cm of thickness, and for photocatalyst Aldrich it was 0.3 g/l in 0.80 cm of thickness.

  6. A Novel Infrared Radiant Glaze Exhibiting Antibacterialand Antifungal Functions

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Infrared radiant powder was synthesized by conventional ceramic processing techniques by using Fe2O3, MnO2, CuO, Co2O3 and kaolin as raw materials. A novel infrared radiant glaze was developed by introducing the infrared radiant powder into glazing as a functional additive. Infrared radiant characteristics of the powder and the glaze were investigated. The optimum content of infrared radiant powder in glazing was ascertained to be 5%. The infrared radiant glaze exhibits significant antibacterial and antifungal functions due to the thermal effect of infrared radiation. Antibacterial percentages of the glaze reach 91%-100% when Escherichia coli, Staphylococcus aureus and Bacillus subtilis are used as model bacterium respectively, while antifungal percentage of the glaze exceeds 95% when Penicillum citrinum is used as model fungus.

  7. Lamb shift of non-degenerate energy level systems placed between two infinite parallel conducting plates

    CERN Document Server

    Billaud, B

    2012-01-01

    The issue of the observability of the Lamb shift in systems with non-degenerate energy levels is put to question. To this end, we compute the Lamb shift of such systems in the electromagnetic environment provided by two infinite parallel conducting plates, which is instrumental in demonstrating the existence of the so-called Casimir effect. A formula giving the relative change in the Lamb shift (as compared to the standard one in vacuum) is explicitly obtained for spherical semiconductor Quantum Dots (QD). It suggests a possibility of QD non-degenerate energy spectrum fine-tuning for experimental purposes as well as a {\\it Gedankenexperiment} to observe the Lamb shift in spherical semiconductor quantum dots.

  8. Earthquake depth-energy release: thermomechanical implications for dynamic plate theory

    CERN Document Server

    Patton, Regan L

    2012-01-01

    Analysis of the global centroid-moment tensor catalog reveals significant regional variations of seismic energy release to 290 km depth. These variations reflect radial and lateral contrasts in thermomechanical competence, consistent with a shear-dominated non-adiabatic boundary layer some 700-km thick, capped by denser oceanic lithosphere as much as 100 km thick, or lighter continental tectosphere 170 to 260 km thick. Thus, isobaric shearing at fractally-distributed depths likely facilitates toroidal plate rotations while minimizing global energy dissipation. Shear localization in the shallow crust occurs as dislocations at finite angles with respect to the shortening direction, with a 30 degree angle being the most likely. Consequently, relatively low-angle reverse faults, steep normal faults, and triple junctions with orthogonal or hexagonal symmetry are likely to form in regions of crustal shortening, extension, and transverse motion, respectively. Thermomechanical theory also predicts adiabatic condition...

  9. Absolute Calibration of Image Plate for electrons at energy between 100 keV and 4 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Chen, H; Back, N L; Eder, D C; Ping, Y; Song, P M; Throop, A

    2007-12-10

    The authors measured the absolute response of image plate (Fuji BAS SR2040) for electrons at energies between 100 keV to 4 MeV using an electron spectrometer. The electron source was produced from a short pulse laser irradiated on the solid density targets. This paper presents the calibration results of image plate Photon Stimulated Luminescence PSL per electrons at this energy range. The Monte Carlo radiation transport code MCNPX results are also presented for three representative incident angles onto the image plates and corresponding electron energies depositions at these angles. These provide a complete set of tools that allows extraction of the absolute calibration to other spectrometer setting at this electron energy range.

  10. Simulation studies of hadron energy resolution as a function of iron plate thickness at INO-ICAL

    Science.gov (United States)

    Lakshmi, S. M.; Ghosh, A.; Devi, M. M.; Kaur, D.; Choubey, S.; Dighe, A.; Indumathi, D.; Murthy, M. V. N.; Naimuddin, Md

    2014-09-01

    We report on a detailed simulation study of the hadron energy resolution as a function of the thickness of the absorber plates for the proposed Iron Calorimeter (ICAL) detector at the India-based Neutrino Observatory (INO). We compare the hadron resolutions obtained with absorber thicknesses in the range 1.5-8 cm for neutrino interactions in the energy range 2-15 GeV, which is relevant to hadron production in atmospheric neutrino interactions. We find that at lower energies, the thickness dependence of energy resolution is steeper than at higher energies, however there is a thickness-independent contribution that dominates at the lower thicknesses discussed in this work. As a result, the gain in hadron energy resolution with decreasing plate thickness is marginal. We present the results in the form of fits to a function with energy-dependent exponent.

  11. EVALUATION OF FLAT-PLATE PHOTOVOLTAIC THERMAL HYBRID SYSTEMS FOR SOLAR ENERGY UTILIZATION.

    Energy Technology Data Exchange (ETDEWEB)

    ANDREWS,J.W.

    1981-06-01

    The technical and economic attractiveness of combined photovoltaic/thermal (PV/T) solar energy collectors was evaluated. The study was limited to flat-plate collectors since concentrating photovoltaic collectors require active cooling and thus are inherently PV/T collectors, the only decision being whether to use the thermal energy or to dump it. it was also specified at the outset that reduction in required roof area was not to be used as an argument for combining the collection of thermal and electrical energy into one module. Three tests of economic viability were identified, all of which PV/T must pass if it is to be considered a promising alternative: PV/T must prove to be competitive with photovoltaic-only, thermal-only, and side-by-side photovoltaic-plus-thermal collectors and systems. These three tests were applied to systems using low-temperature (unglazed) collectors and to systems using medium-temperature (glazed) collectors in Los Angeles, New York, and Tampa. For photovoltaics, the 1986 DOE cost goals were assumed to have been realized, and for thermal energy collection two technologies were considered: a current technology based on metal and glass, and a future technology based on thin-film plastics. The study showed that for medium-temperature applications PV/T is not an attractive option in any of the locations studied. For low-temperature applications, PV/T appears to be marginally attractive.

  12. EVALUATION OF FLAT-PLATE PHOTOVOLTAIC THERMAL HYBRID SYSTEMS FOR SOLAR ENERGY UTILIZATION.

    Energy Technology Data Exchange (ETDEWEB)

    ANDREWS,J.W.

    1981-06-01

    The technical and economic attractiveness of combined photovoltaic/thermal (PV/T) solar energy collectors was evaluated. The study was limited to flat-plate collectors since concentrating photovoltaic collectors require active cooling and thus are inherently PV/T collectors, the only decision being whether to use the thermal energy or to dump it. it was also specified at the outset that reduction in required roof area was not to be used as an argument for combining the collection of thermal and electrical energy into one module. Three tests of economic viability were identified, all of which PV/T must pass if it is to be considered a promising alternative: PV/T must prove to be competitive with photovoltaic-only, thermal-only, and side-by-side photovoltaic-plus-thermal collectors and systems. These three tests were applied to systems using low-temperature (unglazed) collectors and to systems using medium-temperature (glazed) collectors in Los Angeles, New York, and Tampa. For photovoltaics, the 1986 DOE cost goals were assumed to have been realized, and for thermal energy collection two technologies were considered: a current technology based on metal and glass, and a future technology based on thin-film plastics. The study showed that for medium-temperature applications PV/T is not an attractive option in any of the locations studied. For low-temperature applications, PV/T appears to be marginally attractive.

  13. Experimental study on condensation heat transfer of steam on vertical titanium plates with different surface energies

    Energy Technology Data Exchange (ETDEWEB)

    Baojin, Qi; Li, Zhang; Hong, Xu; Yan, Sun [State-Key Laboratory of Chemical Engineering, School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai 200237 (China)

    2011-01-15

    Visual experiments were employed to investigate heat transfer characteristics of steam on vertical titanium plates with/without surface modifications for different surface energies. Stable dropwise condensation and filmwise condensation were achieved on two surface modification titanium plates, respectively. Dropwise and rivulet filmwise co-existing condensation form of steam was observed on unmodified titanium surfaces. With increase in the surface subcooling, the ratio of area ({eta}) covered by drops decreased and departure diameter of droplets increased, resulting in a decrease in condensation heat transfer coefficient. Condensation heat transfer coefficient decreased sharply with the values of {eta} decreasing when the fraction of the surface area covered by drops was greater than that covered by rivulets. Otherwise, the value of {eta} had little effect on the heat transfer performance. Based on the experimental phenomena observed, the heat flux through the surface was proposed to express as the sum of the heat flux through the dropwise region and rivulet filmwise region. The heat flux through the whole surface was the weighted mean value of the two regions mentioned above. The model presented explains the gradual change of heat transfer coefficient for transition condensation with the ratio of area covered by drops. The simulation results agreed well with the present experimental data when the subcooling temperature is lower than 10 C. (author)

  14. A system for the comparison of tools for the simulation of water-based radiant heating and cooling systems

    DEFF Research Database (Denmark)

    Behrendt, Benjamin; Raimondo, Daniela; Zhang, Ye

    2011-01-01

    increase of water based radiant systems in modern buildings and a need for reliable simulation tools to predict the indoor environment and energy performance. This paper describes the comparison of the building simulation tools IDA ICE, IES , EnergyPlus and TRNSYS. The simulation tools are compared to each...

  15. 46 CFR 59.15-10 - Bagged or blistered shell plates.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Bagged or blistered shell plates. 59.15-10 Section 59.15... shell plates. (a) When the shell plates of cylindrical boilers which are exposed to the radiant heat of... boiler. (b) Where the shell plate is bagged due to overheating, the Officer in Charge, Marine...

  16. Load calculations of radiant cooling systems for sizing the plant

    DEFF Research Database (Denmark)

    Bourdakis, Eleftherios; Kazanci, Ongun Berk; Olesen, Bjarne W.

    2015-01-01

    The aim of this study was, by using a building simulation software, to prove that a radiant cooling system should not be sized based on the maximum cooling load but at a lower value. For that reason six radiant cooling models were simulated with two control principles using 100%, 70% and 50% of t...

  17. Load calculations of radiant cooling systems for sizing the plant

    DEFF Research Database (Denmark)

    Bourdakis, Eleftherios; Kazanci, Ongun Berk; Olesen, Bjarne W.

    2015-01-01

    The aim of this study was, by using a building simulation software, to prove that a radiant cooling system should not be sized based on the maximum cooling load but at a lower value. For that reason six radiant cooling models were simulated with two control principles using 100%, 70% and 50...

  18. Localizing Energy Sources and Sinks in Plates Using Power Flow Maps Computed From Laser Vibrometer Measurements

    Directory of Open Access Journals (Sweden)

    J.R.F. Arruda

    1998-01-01

    Full Text Available This paper presents an experimental method especially adapted for the computation of structural power flow using spatially dense vibration data measured with scanning laser Doppler vibrometers. In the proposed method, the operational deflection shapes measured over the surface of the structure are curve-fitted using a two-dimensional discrete Fourier series approximation that minimizes the effects of spatial leakage. From the wavenumber-frequency domain data thus obtained, the spatial derivatives that are necessary to determine the structural power flow are easily computed. Divergence plots are then obtained from the computed intensity fields. An example consisting of a rectangular aluminum plate supported by rubber mounts and excited by a point force is used to appraise the proposed method. The proposed method is compared with more traditional finite difference methods. The proposed method was the only to allow the localization of the energy source and sinks from the experimental divergence plots.

  19. 新型低温热水辐射供暖地面与墙面构造实验研究%Experimental research of a new radiant heating floor and wall structure with low temperature hot water

    Institute of Scientific and Technical Information of China (English)

    费玉敏; 王随林; 闫全英

    2011-01-01

    Presents the new radiant heating floor and wall structure and establishes the experimental system. Researches thermal properties of floor radiant heating with wood floor and ceramic tile and wall radiant heating with perforated honeycomb aluminum plate and imperforated honeycomb aluminum plate by experiment. The results show that, for wall radiant heating, the temperature and the heat flux of perforated honeycomb aluminum plate are higher than those of imperforated honeycomb aluminum plate; for floor radiant heating, the temperature and the heat flux of ceramic tile are higher than those of wood floor..The radiant heating ratio is more than 57 percent for floor radiant heating, and 65 percent for wall radiant heating.%介绍了新型低温热水辐射供暖地面和墙面的构造并建立了实验系统.实验研究了地面供暖和墙面供暖的热工性能,地面辐射供暖分别采用了木地板面层和瓷砖面层,墙面辐射供暖分别采用了有孔蜂窝铝板面层和无孔蜂窝铝板面层.实验结果表明,对于墙面辐射供暖,有孔蜂窝铝板加热面的温度及热流密度大于无孔蜂窝铝板;对于地面辐射供暖,瓷砖面层的表面温度及热流密度大于木地板.地面辐射供暖的辐射传热比例大于57%,墙面辐射供暖的辐射传热比例大于65%.

  20. Volumetric initiation of gaseous detonation by radiant heating of suspended microparticles

    Science.gov (United States)

    Efremov, V. P.; Ivanov, M. F.; Kiverin, A. D.; Yakovenko, I. S.

    2016-02-01

    The concept of detonation wave initiation in the local volume of a fuel-gas mixture containing suspended chemically neutral microparticles heated by radiant energy from an external source is proposed. Mechanisms of initiation of the combustion and detonation waves in a region of accumulation of the radiation- heated microparticles have been studied by numerical simulation methods. Criteria that determine geometric dimensions of a region of the two-phase medium, which are necessary for the initiation of detonation waves, are formulated.

  1. The Temperature Condition of the Plate with Temperature-Dependent Thermal Conductivity and Energy Release

    Directory of Open Access Journals (Sweden)

    V. S. Zarubin

    2016-01-01

    Full Text Available The temperature state of a solid body, in addition to the conditions of its heat exchange with the environment, can greatly depend on the heat release (or heat absorption processes within the body volume. Among the possible causes of these processes should be noted such as a power release in the fuel elements of nuclear reactors, exothermic or endothermic chemical reactions in the solid body material, which respectively involve heat release or absorbtion, heat transfer of a part of the electric power in the current-carrying conductors (so-called Joule’s heat or the energy radiation penetrating into the body of a semitransparent material, etc. The volume power release characterizes an intensity of these processes.The extensive list of references to the theory of heat conductivity of solids offers solutions to problems to determine a stationary (steady over time and non-stationary temperature state of the solids (as a rule, of the canonical form, which act as the sources of volume power release. Thus, in general case, a possibility for changing power release according to the body volume and in solving the nonstationary problems also a possible dependence of this value on the time are taken into consideration.However, in real conditions the volume power release often also depends on the local temperature, and such dependence can be nonlinear. For example, with chemical reactions the intensity of heat release or absorption is in proportion to their rate, which, in turn, is sensitive to the temperature value, and a dependence on the temperature is exponential. A further factor that in such cases makes the analysis of the solid temperature state complicated, is dependence on the temperature and the thermal conductivity of this body material, especially when temperature distribution therein  is significantly non-uniform. Taking into account the influence of these factors requires the mathematical modeling methods, which allow us to build an adequate

  2. Experimental investigation of broadband energy harvesting of a bi-stable composite piezoelectric plate

    Science.gov (United States)

    Pan, Diankun; Ma, Benbiao; Dai, Fuhong

    2017-03-01

    In this work, a bi-stable vibration energy harvester is presented to scavenge energy from ambient vibrations over a wide frequency range. This bi-stable harvester consists of a bi-stable hybrid composite plate as host structure and several pieces of piezoelectric ceramics. Three linear harvesters with the same geometry were employed as the control samples to illustrate the advantages of this bi-stable harvester. The voltage–frequency responses were measured with different g-level excitations, and the output powers across various resistances were measured at different frequencies and accelerations. Unlike the linear harvesters which are effective only near their natural frequencies, the obvious nonlinearities of this bi-stable harvester broaden its working bandwidth. Additionally, the characteristics of this bi-stable host structure contribute to the output power. Under the same condition, when this bi-stable harvester is under cross-well oscillation pattern the maximum output powers are several times higher than those of the linear harvesters. The measured highest output power of this bi-stable harvester is 36.2 mW with 38 Hz frequency and 5g acceleration (g = 9.8 m s‑2).

  3. Efficiency of liquid flat-plate solar energy collector with solar tracking system

    Directory of Open Access Journals (Sweden)

    Chekerovska Marija

    2015-01-01

    Full Text Available An extensive testing programme is performed on a solar collector experimental set-up, installed on a location in Shtip (Republic of Macedonia, latitude 41º 45’ and longitude 22º 12’, in order to investigate the effect of the sun tracking system implementation on the collector efficiency. The set-up consists of two flat plate solar collectors, one with a fixed surface tilted at 30о towards the South, and the other one equipped with dual-axis rotation system. The study includes development of a 3-D mathematical model of the collectors system and a numerical simulation programme, based on the computational fluid dynamics (CFD approach. The main aim of the mathematical modelling is to provide information on conduction, convection and radiation heat transfer, so as to simulate the heat transfer performances and the energy capture capabilities of the fixed and moving collectors in various operating modes. The feasibility of the proposed method was confirmed by experimental verification, showing significant increase of the daily energy capture by the moving collector, compared to the immobile collector unit. The comparative analysis demonstrates a good agreement between the experimental and numerically predicted results at different running conditions, which is a proof that the presented CFD modelling approach can be used for further investigations of different solar collectors configurations and flow schemes.

  4. Measurement of air temperature in the presence of a large radiant flux: an assessment of passively ventilated thermometer screens

    Science.gov (United States)

    Erell, Evyatar; Leal, Vítor; Maldonado, Eduardo

    The energy balance of small temperature sensors was modelled to illustrate the effects of sensor characteristics, particularly size, on the accuracy of readings in the presence of strong shortwave or longwave radiant loads. For all but extremely small sensors, radiant exchange may lead to unacceptable errors. The common practice of using passively ventilated instrument screens was evaluated in a series of comparative measurements. The differences resulting from the use of different models of shields may be an order of magnitude greater than the error resulting from sensor calibration. In the absence of technological innovation capable of reducing the error due to radiant exchange to negligible proportions, it is suggested that a standard methodology for calibrating and labelling the error resulting from the characteristics of the screens be adopted, to allow comparison of new data with long-established records.

  5. Studi Eksperimen Analisa Performa Compact Heat Exchanger Circular Tubes Continuous Plate Fin Untuk Pemanfaatan Waste Energy

    Directory of Open Access Journals (Sweden)

    Rachmadi Gewa Saputra

    2014-03-01

    Full Text Available Harga minyak dunia cenderung mengalami peningkatan dalam beberapa tahun terakhir sehingga manusia berfikir untuk memanfaatkan setiap penggunaan minyak bumi. Dengan berkembangnya teknologi saat ini waste energy yang berupa gas hasil pembakaran pada engine dapat dimanfaatkan menjadi bentuk energi lain menggunakan heat recovery system. Pada tugas akhir ini dilakukan desain sebuah heat exchanger tipe circular tubes continuous plate fin dengan susunan tube aligned yang digunakan untuk menyerap waste energy yang berupa exhaust gas. Untuk mendapatkan dimensi desain yang sesuai digunakan metode ΔTLMTD. Metode ini digunakan untuk menentukan nilai dari overall heat transfer  desain dari heat exchanger, kemudian dilakukan perhitungan untuk nilai overall heat transfer hitung. Setelah didapatkan nilai dari overall heat transfer secara desain dan hitung maka dilakukan iterasi untuk mendapatkan dimensi heat exchanger yang memiliki nilai error paling kecil antara nilai overall heat transfer desain dan hitung. Untuk pengujian performa dari heat exchanger yang telah didesain maka dilakukan variasi kacepatan exhaust gas yang melewati heat exchanger, yaitu 0.4 m/s, 0.3 m/s, dan 0.2 m/s. Exhaust gas yang digunakan memiliki temperatur 280oC. Pada tugas akhir ini didapatkan desain compact heat exchanger dengan dimensi panjang 0.38 m, lebar 0.45 m, dan tebal 0.04m. Setelah dilakukan pengujian dengan memvariasikan kecepatan dari exhaust gas yang melewati heat exchanger maka didapatkan bahwa nilai dari qaktual dari heat exchanger mengalami kenaikan dengan bertambahnya reynolds number akibat bertambahnya kecepatan exhaust gas, kemudian nilai dari effectiveness akan mengalami penurunan untuk setiap kenaikan dari reynold number exhaust gas. Selain itu nilai dari NTU heat exchanger juga mengalami penurunan dengan bertambahnya reynold number exhaust gas. Untuk nilai overall heat transfer dari heat exchanger yang didesain akan mengalami kenaikan akibat bertambahnya nilai

  6. Radiant heating in high working accommodations, indirectly fueled systems. Final report. Stralingsverwarming in hoge bedrijfsruimten, indirect gestookte systemen. Eindrapportage ISSO-kontaktgroep 13. 1

    Energy Technology Data Exchange (ETDEWEB)

    Hogeling, J.; ' t Hooft, E.N.; Van Deventer, H.C.; Wijsman, A.; Lohman, J.; Mastenbroek, C.; Heimeriks, J.H.M.

    1988-01-01

    Research on low temperature radiant heating has been carried out. The aim is to formulate design guidelines and energy consumption calculation methods with regard to low temperature radiant heating. Computer codes have been developed to simulate heat flows in a space heated by radiation. These computerized simulations have been validated by real measured data. By means of the simulation models manual calculation methods were deducted for simple applications. For complex applications it is necessary to use the computer models. The research includes literature searches, design of theoretical models and experimental research. Finally conclusions and recommendations are given with regard to radiant heating application: the choice of installation, construction and control of the system as well as the constructional aspects of a building with radiant heating.

  7. Numerical analysis of diffuse ceiling ventilation and its integration with a radiant ceiling system

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per Kvols; Chen, Qingyan;

    2016-01-01

    number of design parameters encountered in practice. This study aimed to develop a numerical model that can reliably predict the airflow and thermal performance of the integrated system during the design stage. The model was validated by experiments under different operating conditions. The validated......A novel system combining diffuse ceiling ventilation and radiant ceiling was proposed recently, with the aim of providing energy efficient and comfort environment to office buildings. Designing of such a system is challenging because of complex interactions between the two subsystems and a large...... model was further applied to evaluate the effects of different design parameters, including the U-value of the diffuse ceiling panel, plenum height, plenum depth, and inlet configuration. In the integrated system, diffuse ceiling separated the radiant ceiling from the rest of the room and consequently...

  8. FROM ENERGY IMPROVEMENT TO ACCURACY ENHANCEMENT:IMPROVEMENT OF PLATE BENDING ELEMENTS BY THE COMBINED HYBRID METHOD

    Institute of Scientific and Technical Information of China (English)

    Xiao-ping Xie

    2004-01-01

    By following the geometric point of view in mechanics, a novel expression of the combined hybrid method for plate bending problems is introduced to clarify its intrinsic mechanism of enhancing coarse-mesh accuracy of conforming or nonconforming plate elements.By adjusting the combination parameter α∈ (0, 1) and adopting appropriate bending moments modes, reduction of energy error for the discretized displacement model leads to enhanced numerical accuracy. As an application, improvement of Adini's rectangle is discussed. Numerical experiments show that the combined hybrid counterpart of Adini's element is capable of attaining high accuracy at coarse meshes.

  9. Application of image plate for structural studies of carbon nanotubes by high-energy X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Hawelek, L. [A. Chelkowski Institute of Physics, University of Silesia, ul. Uniwersytecka 4, 40-007 Katowice (Poland); Koloczek, J. [A. Chelkowski Institute of Physics, University of Silesia, ul. Uniwersytecka 4, 40-007 Katowice (Poland); Burian, A. [A. Chelkowski Institute of Physics, University of Silesia, ul. Uniwersytecka 4, 40-007 Katowice (Poland)]. E-mail: burian@us.edu.pl; Dore, J.C. [School of Physical Sciences, University of Kent, Canterbury CT2 7NR (United Kingdom); Honkimaeki, V. [European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble (France); Kyotani, T. [Institute of Multidisciplinary Research and Advanced Materials, Tohoku University, Katahira, Sendai 980-8577 (Japan)

    2005-09-29

    An image plate detector coupled with high-energy synchrotron radiation was used to determine the structure factor and the radial distribution function of carbon nanotubes obtained by a template CVD process. The image plate detector has proved to be a very efficient tool for structural studies of nanotubes providing diffraction data of good quality in relatively short time. The diffraction data were converted to real space yielding the radial distribution function which can be used for quantitative analysis of the atomic arrangement of the carbon nanotubes. The obtained results are compared to those of traditional experiments using a conventional point Ge detector.

  10. Radiant heat testing of the H1224A shipping/storage container

    Energy Technology Data Exchange (ETDEWEB)

    Harding, D.C.; Bobbe, J.G.; Stenberg, D.R.; Arviso, M.

    1994-05-01

    H1224A weapons containers have been used for years by the Departments of Energy and Defense to transport and store W78 warhead midsections. Although designed to protect the midsections only from low-energy impacts, a recent transportation risk assessment effort has identified a need to evaluate the container`s ability to protect weapons in more severe accident environments. Four radiant heat tests were performed: two each on an H1224A container (with a Mk12a Mod 6c mass mock-up midsection inside) and two on a low-cost simulated H1224A container (with a hollow Mk12 aeroshell midsections inside). For each unit tested, temperatures were recorded at numerous points throughout the container and midsection during a 4-hour 121{degrees}C (250{degrees}F) and 30-minute 1010{degrees}C (1850{degrees}F) radiant environment. Measured peak temperatures experienced by the inner walls of the midsections as a result of exposure to the high-temperature radiant environment ranged from 650{degrees} C to 980{degrees} C (1200{degrees} F to 1800{degrees}F) for the H1224A container and 770 {degrees} to 990 {degrees}C (1420{degrees} F to 1810{degrees}F) for the simulated container. The majority of both containers were completely destroyed during the high-temperature test. Temperature profiles will be used to benchmark analytical models and predict warhead midsection temperatures over a wide range of the thermal accident conditions.

  11. Simplified Building Thermal Model Used for Optimal Control of Radiant Cooling System

    Directory of Open Access Journals (Sweden)

    Lei He

    2016-01-01

    Full Text Available MPC has the ability to optimize the system operation parameters for energy conservation. Recently, it has been used in HVAC systems for saving energy, but there are very few applications in radiant cooling systems. To implement MPC in buildings with radiant terminals, the predictions of cooling load and thermal environment are indispensable. In this paper, a simplified thermal model is proposed for predicting cooling load and thermal environment in buildings with radiant floor. In this thermal model, the black-box model is introduced to derive the incident solar radiation, while the genetic algorithm is utilized to identify the parameters of the thermal model. In order to further validate this simplified thermal model, simulated results from TRNSYS are compared with those from this model and the deviation is evaluated based on coefficient of variation of root mean square (CV. The results show that the simplified model can predict the operative temperature with a CV lower than 1% and predict cooling loads with a CV lower than 10%. For the purpose of supervisory control in HVAC systems, this simplified RC thermal model has an acceptable accuracy and can be used for further MPC in buildings with radiation terminals.

  12. Continuous distributed phase-plate advances for high-energy laser systems

    Science.gov (United States)

    Marozas, J. A.; Collins, T. J. B.; Zuegel, J. D.; McKenty, P. W.; Cao, D.; Fochs, S.; Radha, P. B.

    2016-05-01

    The distributed phase plate (DPP) design code Zhizhoo’ has been used to design full- aperture, continuous near-field transmission optics for a wide variety of high-fidelity focal-spot shapes for high-energy laser systems: OMEGA EP, Dynamic Compression Sector (DCS), and the National Ignition Facility (NIF). The envelope shape, or profile, of the focal spot affects the hydrodynamics of directly driven targets in these laser systems. Controlling the envelope shape to a high degree of fidelity impacts the quality of the ablatively driven implosions. The code Zhizhoo’ not only produces DPP's with great control of the envelope shape, but also spectral and gradient control as well as robustness from near-field phase aberrations. The focal-spot shapes can take on almost any profile from symmetric to irregular patterns and with high fidelity relative to the objective function over many decades of intensity. The control over the near-field phase spectrum and phase gradients offer greater manufacturability of the full- aperture continuous surface-relief pattern. The flexibility and speed of the DPP design code Zhizhoo’ will be demonstrated by showing the wide variety of successful designs that have been made and those that are in progress.

  13. District heating by radiant heat recovery from cement kilns

    Energy Technology Data Exchange (ETDEWEB)

    Caputo, Antonio C.; Palumbo, Mario; Pelagagge, Pacifico M.; Salini, Paolo [University of L' Aquila, Monteluco (Italy). Dept. of Mechanical, Energy and Management Engineering]. E-mail: caputo@ing.univaq.it; palumbo@ing.univaq.it; pelmar@ing.univaq.it; salini@ing.univaq.it

    2008-07-01

    Heat loss from rotary kilns may represent a significant percentage of the total energy input especially in high energy-intensive industrial sectors such as cement production. In this paper the technical and economic feasibility of recovering radiant heat lost through the kiln surface, by means of a secondary external shell acting as a heat exchanger for a transfer fluid, is evaluated for district heating purposes. At first the system architecture is outlined and a technical and economical model addressing both the performances and cost estimation for the heat exchanger and the district heating network is developed. Subsequently, a parametric profitability analysis is carried out with reference to some relevant parameters characterizing the available recoverable waste heat and the size of the heat distribution network, namely the distance between kiln and user area and extension of the district heating network. This is made to obtain a mapping of the conditions were the proposed heat recovery system is economically feasible. In the paper it is demonstrated that the relevant heat consumption of cement production may make the district heating option for heat recovery a viable one even in case of low density of inhabitants in the surroundings of the plant. Furthermore significant fuel savings and emission reductions are achieved respect the adoption of traditional residential boilers. author)

  14. Thermal Performance Analysis of Reinforced Concrete Floor Structure with Radiant Floor Heating System in Apartment Housing

    Directory of Open Access Journals (Sweden)

    Young-Sun Jeong

    2015-01-01

    Full Text Available The use of the resilient materials in the radiant floor heating systems of reinforced concrete floor in apartment housing is closely related to the reduction of the floor impact sound and the heating energy loss. This study examined the thermal conductivity of expanded polystyrene (EPS foam used for the resilient material in South Korea and analysed the thermal transfer of reinforced concrete floor structure according to the thermal conductivity of the resilient materials. 82 EPS specimens were used to measure the thermal conductivity. The measured apparent density of EPS resilient materials ranged between 9.5 and 63.0 kg/m3, and the thermal conductivity ranged between 0.030 and 0.046 W/(m·K. As the density of resilient materials made of expanded polystyrene foam increases, the thermal conductivity tends to proportionately decrease. To set up reasonable thermal insulation requirements for radiant heating floor systems, the thermal properties of floor structure according to thermal insulation materials must be determined. Heat transfer simulations were performed to analyze the surface temperature, heat loss, and heat flow of floor structure with radiant heating system. As the thermal conductivity of EPS resilient material increased 1.6 times, the heat loss was of 3.4% increase.

  15. Optimal air-supply mode of hybrid system with radiant cooling and dedicated outdoor air

    Institute of Scientific and Technical Information of China (English)

    丁研; 田喆; 朱能

    2015-01-01

    The hybrid system with radiant cooling and dedicated outdoor air not only possesses high energy efficiency, but also creates a healthy and comfortable indoor environment. Indoor air quality will be improved by the dedicated outdoor air system (DOAS) and indoor thermal comfort can be enhanced by the radiant cooling system (RCS). The optimal air-supply mode of the hybrid system and the corresponding design approach were investigated. A full-scale experimental chamber with various air outlets and the ceiling radiant cooling panels (CRCP) was designed and established. The performances of different air-supply modes along with CRCPs were analyzed by multi-index evaluations. Preliminary investigations were also conducted on the humidity stratification and the control effect of different airflow modes to prevent condensation on CRCP. The overhead supply air is recommended as the best combination mode for the hybrid system after comprehensive comparison of the experiment results. The optimal proportion of CRCP accounting for the total cooling capacities in accord with specific cooling loads is found, which may provide valuable reference for the design and operation of the hybrid system.

  16. Growth and solar energy conversion of Azolla sp., cultivated under four solar irradiance flux density; Crescimento e conversao da energia solar de Azolla sp. cultivada em quatro densidades do fluxo radiante

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, E.F. de [Acre Univ., Rio Branco, AC (Brazil); Lopes, N.F. [Vicosa Univ., MG (Brazil). Dept. de Biologia Vegetal

    1994-02-01

    Growth and solar energy conversion were studied in three Azolla species grown under four levels (30, 50, 70 and 100%) of solar radiation incidence under outdoor conditions. Under full sunlight, the specie A. microphylla showed higher crop growth rate, relative growth rate, net assimilation rate and efficiency of solar energy conversion than the other ones. (author). 8 figs., 23 refs.

  17. Radiant{trademark} Liquid Radioisotope Intravascular Radiation Therapy System

    Energy Technology Data Exchange (ETDEWEB)

    Eigler, N.; Whiting, J.; Chernomorsky, A.; Jackson, J.; Knapp, F.F., Jr.; Litvack, F.

    1998-01-16

    RADIANT{trademark} is manufactured by United States Surgical Corporation, Vascular Therapies Division, (formerly Progressive Angioplasty Systems). The system comprises a liquid {beta}-radiation source, a shielded isolation/transfer device (ISAT), modified over-the-wire or rapid exchange delivery balloons, and accessory kits. The liquid {beta}-source is Rhenium-188 in the form of sodium perrhenate (NaReO{sub 4}), Rhenium-188 is primarily a {beta}-emitter with a physical half-life of 17.0 hours. The maximum energy of the {beta}-particles is 2.1 MeV. The source is produced daily in the nuclear pharmacy hot lab by eluting a Tungsten-188/Rhenium-188 generator manufactured by Oak Ridge National Laboratory (ORNL). Using anion exchange columns and Millipore filters the effluent is concentrated to approximately 100 mCi/ml, calibrated, and loaded into the (ISAT) which is subsequently transported to the cardiac catheterization laboratory. The delivery catheters are modified Champion{trademark} over-the-wire, and TNT{trademark} rapid exchange stent delivery balloons. These balloons have thickened polyethylene walls to augment puncture resistance; dual radio-opaque markers and specially configured connectors.

  18. Validation of the uncertainty budget for soft X-ray radiant power measurement using a cryogenic radiometer

    CERN Document Server

    Rabus, H; Scholze, F; Thornagel, R; Ulm, G

    2002-01-01

    The cryogenic radiometer SYRES, a thermal detector based on the electrical substitution principle, has been used as the primary detector standard for radiant power measurement in the ultraviolet, vacuum ultraviolet and soft X-ray spectral ranges. In order to investigate the possibility of radiant energy being deposited in its absorber cavity without being transformed into heat when detecting soft X-rays, SYRES has been directly compared with the electron storage ring BESSY 1, a primary radiometric source standard of calculable spectral radiant power. To this end, the integral radiant power emitted by the storage ring,into a solid angle defined by a high-precision aperture was measured with SYRES. The experiments were conducted at two nominal energies of the circulating electrons, 800 MeV and 340 MeV, to study the influence of the different spectral distributions of the synchrotron radiation. For the original graphite-coated cavity absorber, significant discrepancies were found which could be traced back to th...

  19. Energy deposition onto HL-2A divertor plates in ELMy H-mode discharges using infrared thermography

    Energy Technology Data Exchange (ETDEWEB)

    Gao, J.M., E-mail: gaojm@swip.ac.cn; Li, W.; Liu, Y.; Ji, X.Q.; Cheng, J.; Dong, Y.B.; Chen, C.Y.; Feng, B.B.; Lu, J.; Yi, P.; Yang, Q.W.

    2015-08-15

    Using infrared (IR) thermography, power loads onto the divertor plates have been investigated in ELMy H-mode plasmas on HL-2A. In the ELMy H-mode discharges, ELMs are the largest contributors to the divertor target energy load. Analysis of energy balance shows that up to 45% of the energy losses are deposited onto the divertor targets during ELMs and about 30% are found as plasma radiation. Moreover, divertor heat flux mitigation has been achieved during an ELMy H-mode phase by using Supersonic Molecular Beam Injection (SMBI), characterized by a sharp increase of ELM frequency and a reduction in peak heat flux. The increased plasma radiation energy losses, especially the doubled plasma radiation in the divertor region, should be responsible for the reduction of integrated energy deposition onto divertor targets.

  20. Equivalent circuit modeling of a piezo-patch energy harvester on a thin plate with AC-DC conversion

    Science.gov (United States)

    Bayik, B.; Aghakhani, A.; Basdogan, I.; Erturk, A.

    2016-05-01

    As an alternative to beam-like structures, piezoelectric patch-based energy harvesters attached to thin plates can be readily integrated to plate-like structures in automotive, marine, and aerospace applications, in order to directly exploit structural vibration modes of the host system without mass loading and volumetric occupancy of cantilever attachments. In this paper, a multi-mode equivalent circuit model of a piezo-patch energy harvester integrated to a thin plate is developed and coupled with a standard AC-DC conversion circuit. Equivalent circuit parameters are obtained in two different ways: (1) from the modal analysis solution of a distributed-parameter analytical model and (2) from the finite-element numerical model of the harvester by accounting for two-way coupling. After the analytical modeling effort, multi-mode equivalent circuit representation of the harvester is obtained via electronic circuit simulation software SPICE. Using the SPICE software, electromechanical response of the piezoelectric energy harvester connected to linear and nonlinear circuit elements are computed. Simulation results are validated for the standard AC-AC and AC-DC configurations. For the AC input-AC output problem, voltage frequency response functions are calculated for various resistive loads, and they show excellent agreement with modal analysis-based analytical closed-form solution and with the finite-element model. For the standard ideal AC input-DC output case, a full-wave rectifier and a smoothing capacitor are added to the harvester circuit for conversion of the AC voltage to a stable DC voltage, which is also validated against an existing solution by treating the single-mode plate dynamics as a single-degree-of-freedom system.

  1. The radiant ephemerides of kappa-Cygnids from the IMO video database

    Science.gov (United States)

    Triglav-Cekada, Mihaela

    2006-08-01

    The analysis of single-station IMO video network data of the July and August period with 36 576 meteors in search of kappa-Cygnid, alpha-Lyrid and zeta-Draconid meteor showers was made using the program Radiant. These showers will be named kappa-Cygnid meteor complex radiants. The detailed analysis of the whole August period from 1993-2004 included the behavior of radiants in different magnitude ranges and different years from 2000 on. Detailed radiant calculations for different velocities for 5g and 10g solar longitude intervals were also done. In 10g solar longitude intervals also the calculations for different magnitude ranges were conducted. The activity of the kappa-Cygnid radiant and the alpha-Lyrid radiant was proven, unlike the zeta-Draconid radiant, where no activity could be confirmed. For the whole August period also the behavior of radiants in separate years 2000-2004, when day-to-day meteor coverage is available, was made. From that it can be hinted on alternating bigger activity of the kappa-Cygnid and alpha-Lyrid radiants. In the years 2000 and 2001 the alpha-Lyrid radiant is more active, when on the contrary in 2002, 2003 and 2004 the kappa-Cygnid radiant is more active. The year 2003 is interesting from another aspect, as three radiants can be seen. If the third radiant is the zeta-Draconid radiant, a few years more video observations will have to be gathered and the radiant calculations repeated. For the day of the kappa-Cygnid meteor complex maximum, on August 18, the mean radiant positions were deduced: the more active kappa-Cygnid radiant lies at alpha=280 deg and delta=+58 deg with an area of the maximum probability of 10 deg x 15 deg, and the less active alpha-Lyrid radiant is placed at alpha=292 deg and delta=+52 deg with a radius of maximum probability of 2 deg. The radiant drift was not possible to obtain as in the 5 deg and 10 deg solar longitude interval calculations the positions of both radiants apparently oscillate. As no change can

  2. Radiant heating tests of several liquid metal heat-pipe sandwich panels

    Science.gov (United States)

    Camarda, C. J.; Basiulis, A.

    1983-01-01

    Integral heat pipe sandwich panels, which synergistically combine the thermal efficiency of heat pipes and the structural efficiency of honeycomb sandwich construction, were conceived as a means of alleviating thermal stress problems in the Langley Scramjet Engine. Test panels which utilized two different wickable honeycomb cores, facesheets with screen mesh sintered to the internal surfaces, and a liquid metal working fluid (either sodium or potassium) were tested by radiant heating at various heat load levels. The heat pipe panels reduced maximum temperature differences by 31 percent with sodium working fluid and 45 percent with potassium working fluid. Results indicate that a heat pipe sandwich panel is a potential, simple solution to the engine thermal stress problem. Other interesting applications of the concept include: cold plates for electronic component and circuit card cooling, radiators for large space platforms, low distortion large area structures (e.g., space antennas) and laser mirrors.

  3. Analysis of material characteristics for the construction of energy degrading and scattering plates for electron beam skin radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca, Gabriel P.; Yoriyaz, Helio; Siqueira, Paulo T.D.; Antunes, Paula C.G. [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil)], e-mail: gabriel.fonseca@usp.br, e-mail: hyoriyas@ipen.br, e-mail: ptsiquei@ipen.br, e-mail: pacrisguian@usp.br; Furnari, Laura; Santos, Gabriela R. [Hospital das Clinicas de Sao Paulo, Sao Paulo, SP (Brazil). Inst. de Radiologia. Servico de Radioterapia], e-mail: laurafurnari@hotmail.com, e-mail: reis.gabby@gmail.com

    2009-07-01

    There are many radiosensitive diseases associated to the skin such as mycosis fungoids and the syndrome of Sezary that are part of a sub-group of cutaneous diseases type T-cell lymphoma. Several studies indicate the eradication of the disease when treated with linear accelerators emitting electron beams with energies between 4 to 10 MeV. However, this treatment technique presents innumerable technical challenges since the disease in general reaches all patient's body, becoming necessary a very large field size radiation beam, and also, it should deliver superficial doses limited to the skin depth. To reach the uniformity in the dose distribution, many techniques had already been developed. Based on these previous studies and guided by the report nr. 23 of the AAPM (American Association of Physicists in Medicine), the present study will develop an energy scattering and degrading plates, supplying subsidies for a future installation for skin treatment at the - Servico de Radioterapia do Hospital das Clinicas de Sao Paulo. As part of the plates design, first of all, the energy spectrum of the 6 MeV electron beam of the VARIAN 2100C accelerator was reconstructed through Monte Carlo simulations using the MCNP4C code and based on experimental data. Once the spectrum is built the design of the plates has been performed analyzing several materials, shapes and dimensions most adequate on the basis of radial and axial dose distribution, production of rays-x and dose attenuation. The simulations will be validated with experimental measurements using copper and aluminum. (author)

  4. Numerical Investigation of a Tuned Heave Plate Energy-Harvesting System of a Semi-Submersible Platform

    Directory of Open Access Journals (Sweden)

    Kun Liu

    2016-01-01

    Full Text Available A novel tuned heave plate energy-harvesting system (THPEH is presented for the motion suppressing and energy harvesting of a semi-submersible platform. This THPEH system is designed based on the principle of a tuned mass damper (TMD and is composed of spring supports, a power take-off system (PTO and four movable heave plates. The permanent magnet linear generators (PMLG are used as the PTO system in this design. A semi-submersible platform operating in the South China Sea is selected as the research subject for investigating the effects of the THPEH system on motion reduction and harvesting energy through numerical simulations. The numerical model of the platform and the THPEH system, which was established based on hydrodynamic analysis, is modified and validated by the results of the flume test of a 1:70 scale model. The effects of the parameters, including the size, the frequency ratio and the damping ratio of the THPEH system, are systematically investigated. The results show that this THPEH system, with proper parameters, could significantly reduce the motions of the semi-submersible platform and generate considerable power under different wave conditions.

  5. Thermoregulation: incubators, radiant warmers, artificial skins, and body hoods.

    Science.gov (United States)

    LeBlanc, M H

    1991-09-01

    Keeping babies warm whether using incubator or radiant warmers is important in optimizing their chances of survival. Many design changes have occurred in devices for keeping babies warm, while few controlled studies using clinically important end points have been conducted to assess these changes. Radiant warmers produce larger evaporative heat and water losses and slightly higher basal metabolic rate than incubators. The clinical significance of the higher metabolic rate is uncertain. The water losses create an additional problem in managing infants under radiant warmers. The use of hoods made of thin plastic films to raise local humidity and reduce evaporative water loss helps control this problem. In incubators, humidity may be necessary to provide a warm enough environment for the most immature infants. Artificial skins as yet have not supplanted body hoods for this purpose. Both incubators and radiant warmers produce temperature instability when used as skin servocontrolled devices. There are, however, no data currently available to say how much thermal instability can be well tolerated by a baby. Too much thermal instability produces apnea and increased mortality. Air servocontrolling an incubator reduces environmental temperature instability.

  6. 热舒适性情况下的低温地板辐射供暖节能研究%The thermal comfort conditions of low-temperature radiant floor heating system energy saving research

    Institute of Scientific and Technical Information of China (English)

    靳俊杰; 唐中华; 高理福; 唐莉

    2013-01-01

    Through the comfort temperature range of 16 ℃ ~ 18 ℃,14 ℃ ~ 16 ℃ intermittent heating experiment of low-temperature floor radiation,the temperature of outdoor air,indoor air temperature of each measuring point,the floor surface temperature,supply and return water temperature and water flow are measured,and they are contrasted with the intermittent heating of work and continuous heating throughout the day.The results showed that,under the condition of thermal comfort of intermittent heating,small temperature gradient changes,the human comfort better than traditional intermittent heating at the same time,energy saving effect is obvious.Future universal heating in winter in the southwest has become a trend,the experiment provides reference and basis for the study of low-temperature floor radiation intermittent heating operation in the winter of southwest region.%通过对在舒适性温度范围内16c℃~18℃、14℃~16℃进行低温地板辐射间歇供暖试验,测量了室外空气温度、室内各个测点的空气温度、地板表面温度、供回水温度及水流量,并与上班期间间歇供暖及全天连续供暖进行对比.结果表明,在满足热舒适性情况下间歇供暖,温度梯度变化小,使人的舒适感比传统间歇式供暖要好的同时,节能效果明显.未来西南地区冬季普遍供暖成为了一种趋势,本试验为西南地区冬季低温地板辐射间歇供暖运行研究提供了参考和依据.

  7. First GEANT4-based simulation investigation of a Li-coated resistive plate chamber for low-energy neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, J.T. [Institute for Advanced Physics, Department of Physics, Konkuk University, Seoul 143-701 (Korea, Republic of); Jamil, M., E-mail: mjamil@konkuk.ac.kr [Institute for Advanced Physics, Department of Physics, Konkuk University, Seoul 143-701 (Korea, Republic of); Division of International Studies, University College, Konkuk University, Seoul 143-701 (Korea, Republic of); Jeon, Y.J. [LCD Research Lab, Department of Chemistry, Konkuk University, Seoul 143-701 (Korea, Republic of)

    2013-08-01

    A simulation study of the performance of a single-gap resistive plate chamber coated with Li-layer for the detection of low energy neutrons was performed by means of GEANT4 Monte Carlo code. Low energy neutrons were detected via {sup 7}Li(n, α) {sup 3}He nuclear reaction. To make the detector sensitive to low energy neutrons, Li- coating was employed both on the forward and backward electrodes of the converter. Low energy neutrons were transported onto the Li-coating RPC by GEANT4 MC code. A detector with converter area of 5×5 cm{sup 2} was utilized for this work. The detection response was evaluated as a function of incident low energy neutrons in the range of 25 MeV–100 MeV. The evaluated results predicted higher detection response for the backward-coated converter detector than that of forward coated converter RPC setup. This type of detector can be useful for the detection of low energy neutrons.

  8. Experimental testing of various heat transfer structures in a flat plate thermal energy storage unit

    Science.gov (United States)

    Johnson, Maike; Fiß, Michael; Klemm, Torsten

    2016-05-01

    For solar process heat applications with steam as the working fluid and varying application parameters, a novel latent heat storage concept has been developed using an adaptation of a flat plate heat exchanger as the storage concept. Since the pressure level in these applications usually does not exceed 30 bar, an adaptation with storage material chambers arranged between heat transfer medium chambers is possible. Phase change materials are used as the storage medium, so that the isothermal evaporation of steam during discharging of the storage is paired with the isothermal solidification of the storage material. Heat transfer structures can be inserted into the chambers to adjust the power level for a given application. By combining the required number of flat plate heat exchanger compartments and inserting the appropriate heat transfer structure, the design can easily be adjusted for the required power level and capacity for a specific application. Within this work, the technical feasibility of this concept is proven. The dependence of the operating characteristics on the geometry of the heat exchanger is identified. A focus is on varying the power density by integrating conductive heat structures in the PCM.

  9. Can Integrated Micro-Optical Concentrator Technology Revolutionize Flat-Plate Photovoltaic Solar Energy Harvesting?

    Science.gov (United States)

    Haney, Michael W.

    2015-12-01

    The economies-of-scale and enhanced performance of integrated micro-technologies have repeatedly delivered disruptive market impact. Examples range from microelectronics to displays to lighting. However, integrated micro-scale technologies have yet to be applied in a transformational way to solar photovoltaic panels. The recently announced Micro-scale Optimized Solar-cell Arrays with Integrated Concentration (MOSAIC) program aims to create a new paradigm in solar photovoltaic panel technology based on the incorporation of micro-concentrating photo-voltaic (μ-CPV) cells. As depicted in Figure 1, MOSAIC will integrate arrays of micro-optical concentrating elements and micro-scale PV elements to achieve the same aggregated collection area and high conversion efficiency of a conventional (i.e., macro-scale) CPV approach, but with the low profile and mass, and hopefully cost, of a conventional non-concentrated PV panel. The reduced size and weight, and enhanced wiring complexity, of the MOSAIC approach provide the opportunity to access the high-performance/low-cost region between the conventional CPV and flat-plate (1-sun) PV domains shown in Figure 2. Accessing this portion of the graph in Figure 2 will expand the geographic and market reach of flat-plate PV. This talk reviews the motivation and goals for the MOSAIC program. The diversity of the technical approaches to micro-concentration, embedded solar tracking, and hybrid direct/diffuse solar resource collection found in the MOSAIC portfolio of projects will also be highlighted.

  10. Performance analysis on solar-water compound source heat pump for radiant floor heating system

    Institute of Scientific and Technical Information of China (English)

    曲世林; 马飞; 仇安兵

    2009-01-01

    A solar-water compound source heat pump for radiant floor heating (SWHP-RFH) experimental system was introduced and analyzed. The SWHP-RFH system mainly consists of 11.44 m2 vacuum tube solar collector,1 000 L water tank assisted 3 kW electrical heater,a water source heat pump,the radiant floor heating system with cross-linked polyethylene (PE-X) of diameter 20 mm,temperature controller and solar testing system. The SWHP-RFH system was tested from December to February during the heating season in Beijing,China under different operation situations. The test parameters include the outdoor air temperature,solar radiation intensity,indoor air temperature,radiation floor average surface temperature,average surface temperature of the building envelope,the inlet and outlet temperatures of solar collector,the temperature of water tank,the heat medium temperatures of heat pump condenser side and evaporator side,and the power consumption includes the water source heat pump system,the solar source heat pump system,the auxiliary heater and the radiant floor heating systems etc. The experimental results were used to calculate the collector efficiency,heat pump dynamic coefficient of performance (COP),total energy consumption and seasonal heating performance during the heating season. The results indicate that the performance of the compound source heat pump system is better than that of the air source heat pump system. Furthermore,some methods are suggested to improve the thermal performance of each component and the whole SWHP-RFH system.

  11. Asymmetric Laser Radiant Cooling in Storage Rings

    CERN Document Server

    Bulyak, E V; Zimmermann, F

    2011-01-01

    Laser pulses with small spatial and temporal dimensions can interact with a fraction of the electron bunches circulating in Compton storage rings. We studied synchrotron dynamics of such bunches when laser photons scatter off from the electrons with energy higher than the synchronous energy. In this case of ‘asymmetric cooling', as shown theoretically, the stationary energy spread is much smaller than under conditions of regular scattering; the oscillations are damped faster. Coherent oscillations of large amplitude may be damped in one synchrotron period, which makes this method feasible for injection the bunches into a ring in the longitudinal phase space. The theoretical results are validated with simulations.

  12. Solar energy dryer kinetics using flat-plate finned collector and forced convection for potato drying

    Science.gov (United States)

    Batubara, Fatimah; Misran, Erni; Dina, Sari Farah; Heppy

    2017-06-01

    Research on potato drying using the indirect solar dryer with flat-plate finned collector and forced convection has been done. The research was conducted at the outdoor field of Laboratory of Institute for Research and Standardization of Industry on June 14th-23rd, 2016 from 9:00 am to 4:00 pm. This research aims to obtain the drying kinetics model of potato (Solanumtuberosum L.) using an indirect solar dryer's (ISD) with flat plate-finned collector and forced convection. The result will be compared to the open sun drying (OSD) method. Weather conditions during the drying process took place as follows; surrounding air temperature was in the range 27 to 34.7 °C, relative humidity (RH) 29.5 to 61.0% and the intensity of solar radiation 105.6 to 863.1 Watt/m2. The dried potato thicknesses were 1.0 cm, 1.5 cm and 2.0 cm, with the average initial water content of 76.46%. The average temperature in the collector chamber ranged from 42.2 to 57.4 °C and the drying chamber was at 46.2 °C. The best drying result was obtained from a sample size of 1 cm thickness using the IDS method with an average drying rate of 0.018 kg H2O per kg dry-weight.hour and the water content was constant at 5.02% in 21 hours of drying time. The most suitable kinetics model is Page model, equation MR = exp (-0.049 t1,336) for 1.0 cm thickness, exp (-0.066 t1,222) for 1.5 cm thickness and exp (-0.049 t1,221) for 2.0 cm thickness. The quality of potato drying using ISD method is better than using OSD which can be seen from the color produced.

  13. Droplet kinetic energy of moving spray-plate center-pivot irrigation sprinklers

    Science.gov (United States)

    The kinetic energy of discrete water drops impacting a bare soil surface generally leads to a drastic reduction in water infiltration rate due to formation of a seal on the soil surface. Under center-pivot sprinkler irrigation, kinetic energy transferred to the soil prior to crop canopy development ...

  14. Characterizing droplet kinetic energy applied by moving spray-plate center pivot irrigation sprinklers

    Science.gov (United States)

    The kinetic energy of discrete drops impacting a bare soil surface is generally observed to lead to a drastic reduction in water infiltration rate due to soil surface seal formation. Under center pivot sprinkler irrigation, kinetic energy transferred to the soil prior to crop canopy development can...

  15. A Study of the use of a Crystal as a `Quarter-Wave Plate' to Produce High Energy Circularly Polarized Photons

    CERN Multimedia

    Kononets, I

    2002-01-01

    %NA59 %title\\\\ \\\\We present a proposal to study the use of a crystal as a `quarter-wave plate' to produce high energy circularly polarized photons, starting from unpolarized electrons. The intention is to generate linearly polarized photons by letting electrons pass a crystalline target, where they interact coherently with the lattice nuclei. The photon polarization is subsequently turned into circular polarization after passing another crystal, which acts as a `quarter-wave plate'.

  16. Cooling load calculation by the radiant time series method - effect of solar radiation models

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Alexandre M.S. [Universidade Estadual de Maringa (UEM), PR (Brazil)], E-mail: amscosta@uem.br

    2010-07-01

    In this work was analyzed numerically the effect of three different models for solar radiation on the cooling load calculated by the radiant time series' method. The solar radiation models implemented were clear sky, isotropic sky and anisotropic sky. The radiant time series' method (RTS) was proposed by ASHRAE (2001) for replacing the classical methods of cooling load calculation, such as TETD/TA. The method is based on computing the effect of space thermal energy storage on the instantaneous cooling load. The computing is carried out by splitting the heat gain components in convective and radiant parts. Following the radiant part is transformed using time series, which coefficients are a function of the construction type and heat gain (solar or non-solar). The transformed result is added to the convective part, giving the instantaneous cooling load. The method was applied for investigate the influence for an example room. The location used was - 23 degree S and 51 degree W and the day was 21 of January, a typical summer day in the southern hemisphere. The room was composed of two vertical walls with windows exposed to outdoors with azimuth angles equals to west and east directions. The output of the different models of solar radiation for the two walls in terms of direct and diffuse components as well heat gains were investigated. It was verified that the clear sky exhibited the less conservative (higher values) for the direct component of solar radiation, with the opposite trend for the diffuse component. For the heat gain, the clear sky gives the higher values, three times higher for the peek hours than the other models. Both isotropic and anisotropic models predicted similar magnitude for the heat gain. The same behavior was also verified for the cooling load. The effect of room thermal inertia was decreasing the cooling load during the peak hours. On the other hand the higher thermal inertia values are the greater for the non peak hours. The effect

  17. High energy muon induced radioactive nuclides in nickel plate and its use for 2-D muon-beam image profile

    Energy Technology Data Exchange (ETDEWEB)

    Kurebayashi, Y. [Graduate School of Science and Engineering, Yamagata University, Yamagata 990-8560 (Japan); Sakurai, H., E-mail: sakurail@sci.kj.yamagata-u.ac.jp [Department of Physics, Yamagata University, 1-4-12 Kojirakawa, Yamagata 990-8560 (Japan); Takahashi, Y. [Graduate School of Science and Engineering, Yamagata University, Yamagata 990-8560 (Japan); Doshita, N. [Department of Physics, Yamagata University, 1-4-12 Kojirakawa, Yamagata 990-8560 (Japan); Kikuchi, S. [Graduate School of Science and Engineering, Yamagata University, Yamagata 990-8560 (Japan); Tokanai, F. [Department of Physics, Yamagata University, 1-4-12 Kojirakawa, Yamagata 990-8560 (Japan); Horiuchi, K. [Graduate School of Science and Technology, Hirosaki University, 3, Bunkyo-chou, Hirosaki 036-8561, Aomori (Japan); Tajima, Y. [Institute of Arts and Sciences, Yamagata University, 1-4-12 Kojirakawa, Yamagata 990-8560 (Japan); Oe, T. [Department of Physics, Yamagata University, 1-4-12 Kojirakawa, Yamagata 990-8560 (Japan); Sato, T. [Graduate School of Science and Engineering, Yamagata University, Yamagata 990-8560 (Japan); Gunji, S. [Department of Physics, Yamagata University, 1-4-12 Kojirakawa, Yamagata 990-8560 (Japan); Inui, E. [Faculty of Science, Yamagata University, 1-4-12 Kojirakawa, Yamagata 990-8560 (Japan); Kondo, K. [Department of Physics, Yamagata University, 1-4-12 Kojirakawa, Yamagata 990-8560 (Japan); Iwata, N. [Dept. of Earth and Environmental Science, Yamagata University, 1-4-12 Kojirakawa, Yamagata 990-8560 (Japan); Sasaki, N. [Graduate School of Science and Technology, Hirosaki University, 3, Bunkyo-chou, Hirosaki 036-8561, Aomori (Japan); Matsuzaki, H. [Micro Analysis Laboratory, Tandem accelerator (MALT), The University Museum, The University of Tokyo, 2-11-16, Yayoi, Bunkyo-ku, Tokyo 113-0032 (Japan); Kunieda, S. [Nuclear Data Center, Japan Atomic Energy Agency, Tokai-mura, Naka-gun 319-1195, Ibaraki (Japan)

    2015-11-01

    Target materials were exposed to a muon beam with an energy of 160 GeV/c at the COMPASS experiment line in CERN-SPS to measure the production cross-sections for muon-induced radionuclides. A muon imager containing four nickel plates, each measuring 100 mm×100 mm, exposed to the IP plate successfully detected the muon beam image during an irradiation period of 33 days. The contrasting density rate of the nickel plate was (5.2±0.7)×10{sup –9} PSL/muon per one-day exposure to IP. The image measured 122 mm and 174 mm in horizontal and vertical lengths, respectively, in relation to the surface of the base, indicating that 50±6% of the muon beam flux is confined to an area of 18% of the whole muon beam. The number of muons estimated from the PSL value in the total beam image area (0.81±0.1)×10{sup 13} was comparable to the total muon counts of the ion-chamber at the M2 beam line in the CERN-SPS. The production cross-sections of Cr-51, Mn-54, Co-56, Co-57, and Co-58 in nickel were 0.19±0.08, 0.34±0.06, 0.5±0.05, 3.44±0.07, 0.4±0.03 in the unit of mb, respectively, reducing muon associated particles effects. They are approximately 10 times smaller than that a proceeding study by Heisinger et al.

  18. Analysis and experimental verification of electroacoustic wave energy harvesting in a coupled piezoelectric plate-harvester system

    Science.gov (United States)

    Darabi, Amir; Leamy, Michael J.

    2017-03-01

    This paper introduces an analytical framework for predicting wave energy harvested by a circular piezoelectric disk attached to a thin plate. An harmonic point source excitation generates waves that are then incident on a piezoelectric disk—summing responses due to all such excitation enables general forcing profiles to be considered. The analysis approach decomposes the coupled system into two subdomains, one being the piezoelectric disk, and the other an infinite plate for which a Green's function is readily available. Interaction forces between the two subdomains couple the problems and lead to a closed-form solution for the propagation, transmission, and reflection of waves over the entire domain. In addition, the voltage generated by the harvester is calculated using coupled electromechanical equations. The analysis approach is first validated by comparing predicted response quantities to those computed using numerical simulations, documenting good agreement. The system is then studied in the frequency domain and the optimum harvester resistance is found for generating the most electrical power. Representative experiments are carried out to demonstrate the validity of the analytical approach and verify the harvested power versus resistance trend.

  19. A Study on a Performance of Water-Spray-Type Ice Thermal Energy Storage Vessel with Vertical Heat Exchanger Plates

    Science.gov (United States)

    Yoshimura, Kenji; Sasaguchi, Kengo; Fukuda, Toshihito; Koyama, Shigeru

    A system with a water-embedded-trpe ice storage vessel is widely used because of its simple structure and compactness. However, the water-embedded-type ice storage vessel has a disadvantage, that is, the solidification rate is very small. The use of falling water film seems to be one of promising ways for solving this disadvantage. We have found in a previous study that the use of the falling water film is very effective, especially for high initial water temperatures. In the present study, we eexamined the performance of a faling-water-film-type ice thermal energy storage vessel with pratical size, having vertical heat exchanger plates. The ice making performance coefficient, η, increases with time, and it becomes am aximum value of 2.5, after that, it decreases gradually. In order to make ice efficiently, it is necessary to set a flow rate of refrigerant properly and to adjust a difference between the evaporating temperature of refrigerant and the freezing point of water so that the refrigerant evaporates in the heat exchanger plates overall.

  20. Geo-energy Test Beds: part of the European Plate Observing System

    Science.gov (United States)

    Stephenson, Michael; Schofield, David; Luton, Christopher; Haslinger, Florian; Henninges, Jan; Giardini, Domenico

    2016-04-01

    For 2020, the EU has committed to cutting its greenhouse gas emissions to 20% below 1990 levels and further cuts are being decided for 2050. This commitment is one of the headline targets of the Europe 2020 growth strategy and is being implemented through binding legislation. This decarbonisation of the EU economy is one dimension of an overall EU energy and climate framework that is mutually interlinked with the need to ensure energy security, promote a fully integrated energy market, promote energy efficiency and promote research innovation and competitiveness. Power generation will have to take a particularly large part in emissions reductions (-54 to -68% by 2030 and -93 to -99% by 2050), mainly by focussing on increasing surface renewables (wind, tidal and solar) but also on carbon capture and storage on fossil fuel and biofuel power plants, shale gas, nuclear and geothermal power. All the above generation technologies share common geological challenges around containment, safety and environmental sustainability. In a densely populated continent, this means that high levels of subsurface management are needed to fully realise the energy potential. In response to this need, across Europe, public and private sector funded, experimental test and monitoring facilities and infrastructures (Geo-energy Test Beds, GETB) are being developed. These GETB investigate the processes, technology and practices that facilitate the sustainable exploitation of Geo-energy resources and are of intense interest to the public and regulators alike. The vision of EPOS IP Work Package 17 (wp17) is to promote research and innovation in Geo-energy that reflects core European energy priorities through provision of virtual access to data and protocols and trans-national access to GETB experiments. This will be achieved through provision of access to continuous strategic observations, promotion of the integrated use of data and models from European GETB, development of underpinning research

  1. Indexes of Indoor Thermal Environment with Asymmetrical Radiant Field

    Institute of Scientific and Technical Information of China (English)

    钟珂; 刘加平; 亢燕铭

    2004-01-01

    The main features of top-floor rooms with natural ventilation are identified by investigating indoor thermal environment in summer season. One is high indoor air temperature, for this reason the indoor climate is far beyond the thermal comfort standard; the other is the inhomogeneous temperature distribution of the inner wall surfaces, and high temperature of the inner surface of the roof causes much scorching to the head of occupant. This is the characteristic of such rooms.Both features mentioned above should be considered comprehensively for thc evaluation of indoor thermal environment of the top-floor rooms with asymmetric radiant field. In order to characterize the indoor thermal environment of the rooms, the heat stress index, HSI and radiant heat flux reaching human head, QR should be introduced simultaneously as thermal indexes for the indoor climate evaluation. The application of the indexes to a topfloor room is presented and analyzed.

  2. Use of local convective and radiant cooling at warm environment

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Krejcirikova, Barbora; Kaczmarczyk, Jan

    2012-01-01

    with one panel equipped with small fans. A reference condition without cooling was tested as well. The response of the subjects to the exposed conditions was collected by computerized questionnaires. The cooling devices significantly (p.... The acceptability of the thermal environment was similar for all cooling devices. The acceptability of air movement and PAQ increased when the local cooling methods were used. The best results were achieved with personalized ventilation and cooling fan. The minimal improvement in PAQ was reported when the radiant...

  3. Radiant-and-plasma technology for coal processing

    OpenAIRE

    Vladimir Messerle; Alexander Ustimenko

    2012-01-01

    Radiant-and-plasma technology for coal processing is presented in the article. Thermodynamic computation and experiments on plasma processing of bituminous coal preliminary electron-beam activated were fulfilled in comparison with plasma processing of the coal. Positive influence of the preliminary electron-beam activation of coal on synthesis gas yield was found. Experiments were carried out in the plasma gasifier of 100 kW power. As a result of the measurements of material and heat balance ...

  4. Solid propellant combustion response to oscillatory radiant heat flux

    Science.gov (United States)

    Strand, L. D.; Weil, M. T.; Cohen, N. S.

    1989-01-01

    A progress report is given on a research project to use the microwave Doppler velocimeter technique to measure the combustion response to an oscillating thermal radiation source (CO2 laser). The test technique and supporting analyses are described, and the results are presented for an initial test series on the nonmetallized, composite propellant, Naval Weapons Center formulation A-13. It is concluded that in-depth transmission of radiant heat flux is not a factor at the CO2 laser wave length.

  5. An International Comparison of Absolute Radiant Power Measurement Capabilities

    OpenAIRE

    Thomas, Douglas B.

    1990-01-01

    We report the results of an intercomparison of monochromatic radiant power measurement capabilities recently completed by 11 national laboratories. The intercomparison radiometers, distributed in pairs, included an amplifier with six decades of precision gain and one of two types of silicon photodiode (pn or np-type construction). Eleven of the laboratories measured the absolute responsivity of the radiometers at 633 nm and nine at 488 nm. The standard deviation of the overall difference was ...

  6. An optimized process for the production of advanced planar wire grid plates as detectors for high energy physics experiments

    CERN Document Server

    Iacopi, F; Pins, R; Van Hook, R I; Honore, M; Zhukov, V; Van Lancker, L; Van Doninck, W K; Beyne, E

    2001-01-01

    This paper introduces a novel production technique for the planar wire grid plates of microstrip gas chambers (MSGCs, gaseous particle detectors), taking advantage from the typical thin film metallization technologies. The aim of the work here presented has been to manufacture MSGC substrates which can meet the challenging requirements proper to particle tracking detectors in highly ionizing environments. These requirements are mainly represented by high reliability and robustness, since the devices are supposed to operate efficiently for at least 10 years in the extremely hostile conditions foreseen at the large hadron collider at CERN (CH). A detailed process description will be given and results will be analyzed both from the production point of view and from the application of the manufactured prototypes as detectors for high energy physics experiments. (7 refs).

  7. Study on the law of radiant directionality of row crops

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The style of crops planting is frequently in row-structure,the row-structure style may result in big difference among the sunlit,shaded soil surface and foliage temperatures and cause pixel component to vary in azimuth orientation,these further lead to the change of radiant directionality of row crops in the zenith and azimuth orientations.Since the row crops are often tackled as isotropic in the azimuth orientation based on continuous vegetation assumption,big errors will be brought about.In order to eliminate the errors,it is necessary to study the law of radiant directionality of the row crops.In this paper,Monte Carlo method has been employed to simulate the angular effects on radiation caused by row architecture parameters.The simulated results show that the parameters,for example,row height,row width,row interval between the neighbor rows and the leaf area index have significant influences on the radiant directionality,but the azimuth orientation ranks the first among the parameters.

  8. Development of a simulation tool to evaluate the performance of radiant cooling ceilings

    Energy Technology Data Exchange (ETDEWEB)

    Stetiu, C.; Feustel, H.E.; Winkelmann, F.C.

    1995-06-01

    Considerable electrical energy used to cool nonresidential buildings equipped with All-Air Systems is drawn by the fans that transport the cool air through the thermal distribution system. Hydropic Cooling Systems have the potential to reduce the amount of air transported through the building by separating the tasks of ventilation and thermal conditioning. Due to the physical properties of water, Hydropic Cooling Systems can transport a given amount of thermal energy using less than 5% of the otherwise necessary fan energy. They are suited to the dry climates that are typical of California and been used for more than 30 years in hospital rooms. However, energy savings and peak-load characteristics have not yet been analyzed. Adequate guidelines for their design and control systems has prevented lack of their widespread application to other building types. Evaluation of theoretical performance of Hydropic Systems could be made by computer models. Energy analysis programs such as DOE-2 do not yet have the capacity to simulate Hydropic Cooling Systems. Scope of this project is developing a model that can accurately simulate the dynamic performance of Hydropic Radiant Cooling Systems. The model can calculate loads, heat extraction rates, room air temperature and room surface temperature distributions, and can be used to evaluate issues such as thermal comfort, controls, system sizing, system configuration and dynamic response. The model was created with the LBL Simulation Problem Analysis and Research Kernel (SPARK), which provides a methodology for describing and solving the dynamic, non-linear equations that correspond to complex physical systems. Potential for Hydropic Radiant Cooling Systems applications can be determined by running this model for a variety of construction types in different California climates.

  9. Experimental study of the lift and drag characteristics of a cascade of flat plates in a configuration of interest for tidal energy converters

    Science.gov (United States)

    Fedoul, Faical; Parras, Luis; Del Pino, Carlos; Fernandez-Feria, Ramon

    2012-11-01

    Wind tunnel experiments are conducted for the flow around both a single flat plate and a cascade of three parallel flat plates at different angles of incidence to compare their lift and drag coefficients in a range of Reynolds number about 105, and for two values of the aspect ratio of the flat plates. The selected cascade configuration is of interest for a particular type of tidal energy converter. The lift and drag characteristics of the central plate in the cascade are compared to those of the isolated plate, finding that there exist an angle of incidence, which depends on the Reynolds number and the aspect ratio, above which the effective lift of the plate in the cascade becomes larger than that of an isolated plate. These experimental results, which are also analyzed in the light of theoretical predictions, are used as a guide for the design of the optimum configuration of the cascade which extracts the maximum power from a tidal current for a given value of the Reynolds number. Supported by the Ministerio de Ciencia e Innovacion (Spain) Grant no. ENE2010-16851.

  10. Simulation of the effects of coated material SEY property on output electron energy distribution and gain of microchannel plates

    Science.gov (United States)

    Chen, Lin; Wang, Xingchao; Tian, Jinshou; Liu, Chunliang; Liu, Hulin; Chen, Ping; Wei, Yonglin; Sai, Xiaofeng; Sun, Jianning; Si, Shuguang; Wang, Xing; Lu, Yu; Tian, Liping; Hui, Dandan; Guo, Lehui

    2016-12-01

    To obtain a high spatial resolution of a image intensifier based on microchannel plate (MCP), the long tail in the exit energy distribution of the output electrons (EDOE) is undesirable. The existing solution is increasing the penetration depth of the MCP output electrode, which will result in a serious gain reduction. Coating the MCP output electrode with efficient secondary electron yield (SEY) materials is supposed to be an effective approach to suppress the unfavorable tail component in the EDOE without negative effects on the gain. In our work, a three-dimensional MCP single channel model is developed in CST STUDIO SUITE to systematically investigate the dependences of the EDOE and the gain on the SEY property of the coated material, based on the Finite Integral Technique and Monte Carlo method. The results show that besides the high SEY of the coated material, the low incident energy corresponding to the peak SEY is another essential element affecting the electron yield in the final stage of multiplication and suppressing the output energy spread.

  11. Techniques for computing regional radiant emittances of the earth-atmosphere system from observations by wide-angle satellite radiometers, phase 3

    Science.gov (United States)

    Pina, J. F.; House, F. B.

    1975-01-01

    Radiometers on earth orbiting satellites measure the exchange of radiant energy between the earth-atmosphere (E-A) system and space at observation points in space external to the E-A system. Observations by wideangle, spherical and flat radiometers are analyzed and interpreted with regard to the general problem of the earth energy budget (EEB) and to the problem of determining the energy budget of regions smaller than the field of view (FOV) of these radiometers.

  12. Energy functional derivative with respect to the length of a curvilinear oblique cut in the equilibrium problem for a Timoshenko plate

    Science.gov (United States)

    Lazarev, N. P.

    2015-11-01

    This paper describes the dependence of the solution of the equilibrium problem for a Timoshenko plate and the total energy functional of the plate on the perturbation of an oblique crack. The nonlinearity of the problem is caused by the boundary conditions in the form of inequalities (conditions such as the Signorini conditions), which describe mutual nonpenetration of the opposite crack faces. The continuous dependence of the solution of the problem on the perturbation of the crack length is established. A formula for the energy functional derivative of the perturbation of the crack length is obtained.

  13. Arrays of fixed flat plate solar energy collectors: performance comparisons for differing individual component orientations

    Energy Technology Data Exchange (ETDEWEB)

    Janke, S.H.; Boehm, R.F.

    1977-01-01

    A determination is made regarding the energy density and flux available after passage of direct solar radiation through single and double glass covers, for panels inclined at various angles and oriented with varying azimuths, several latitudes are also considered. Results of a computer program which for any latitude, date, time of day and arbitrary pannel orientation allows for atmospheric attenuation and glass transmission are displayed in several graphical formats. Orientizations other than south facing are found to give greater availability of energy for a period of roughly 90 days centered about the summer solstice, and to give higher flux values early or late in the day for winter dates, but are inferior to south facing pannels in other respects.

  14. Low-energy impact resistance of graphite-epoxy plates and ALS honeycomb sandwich panels

    Science.gov (United States)

    Hui, David

    1989-01-01

    Low energy impact may be potentially dangerous for many highly optimized stiff structures. Impact by foreign objects such as birds, ice, and runways stones or dropping of tools occur frequently and the resulting damage and stress concentrations may be unacceptable from a designer's standpoint. The barely visible, yet potentially dangerous dents due to impact of foreign objects on the Advanced Launch System (ALS) structure are studied. Of particular interest is the computation of the maximum peak impact force for a given impactor mass and initial velocity. The theoretical impact forces will be compared with the experimental dropweight results for the ALS face sheets alone as well as the ALS honeycomb sandwich panels.

  15. Surface free energy of non-stick coatings deposited using closed field unbalanced magnetron sputter ion plating

    Energy Technology Data Exchange (ETDEWEB)

    Sun, C.-C. [Department of Materials Science and Engineering, National Cheng Kung University, Tainan, Taiwan (China); Lee, S.-C. [Department of Materials Science and Engineering, National Cheng Kung University, Tainan, Taiwan (China); Dai, S.-B. [Center of General Studies, National Kaohsiung Marine University, Nan-Tzu, Kaohsiung, Taiwan (China); Nano-Win Technology Co. Ltd., Tainan, Taiwan (China); Tien, S.-L. [Department of Physics, National Cheng Kung University, 701 Tainan, Taiwan (China); Chang, C.-C. [Department of Physics, R.O.C. Military Academy, 830 Kaohsiung, Taiwan (China); Fu, Y.-S. [Department of Environment and Energy, National University of Tainan, Tainan, Taiwan (China)]. E-mail: ysfu@mail.nutn.edu.tw

    2007-02-15

    Semiconductor IC packaging molding dies require wear resistance, corrosion resistance and non-sticking (with a low surface free energy). The molding releasing capability and performance are directly associated with the surface free energy between the coating and product material. The serious sticking problem reduces productivity and reliability. Depositing TiN, TiMoS, ZrN, CrC, CrN, NiCr, NiCrN, CrTiAlN and CrNiTiAlN coatings using closed field unbalanced magnetron sputter ion plating, and characterizing their surface free energy are the main object in developing a non-stick coating system for semiconductor IC molding tools. The contact angle of water, diiodomethane and ethylene glycol on the coated surfaces were measured at temperature in 20 deg. C using a Dataphysics OCA-20 contact angle analyzer. The surface free energy of the coatings and their components (dispersion and polar) were calculated using the Owens-Wendt geometric mean approach. The surface roughness was investigated by atomic force microscopy (AFM). The adhesion force of these coatings was measured using direct tensile pull-off test apparatus. The experimental results showed that NiCrN, CrN and NiCrTiAlN coatings outperformed TiN, ZrN, NiCr, CiTiAlN, CrC and TiMoS coatings in terms of non-sticking, and thus have the potential as working layers for injection molding industrial equipment, especially in semiconductor IC packaging molding applications.

  16. Infrared Radiant Temperatures in the Alpine/Periglacial Environment as Related to Thermal Remote Sensing,

    Science.gov (United States)

    remote sensing in the alpine/periglacial environment. Techniques of ground truth observations were tested by which a researcher might determine the usefulness of infrared scanning to his study without the financial investment of airborne remote sensing on a trial-and-error basis. Also, an attempt was made to determine the environmental controls upon radiant temperature by monitoring changing patterns of radiant temperature relative to changing meteorologic conditions. Observations of both actual and thermal infrared radiant temperatures were made

  17. Dependence of fading patterns of photo-stimulated luminescence from imaging plates on radiation, energy, and image reader

    CERN Document Server

    Ohuchi, H

    2002-01-01

    We have been investigating the fading characteristics of imaging plates (IPs) as integral type detectors. The dependence on alpha, beta, and gamma ray radiation and their energies of the fading effect was measured using three types of IPs (BAS-UR, BAS-TR, and BAS-MS). The functions to correct the fading were determined by using the method reported in a previous paper. In all types of IPs, we confirmed that the fading effect is independent of the energy of the incident particles of beta and gamma rays and also independent of radiation except for the first component, which fades out in a very short time after irradiation with alpha rays. These results are very useful in the utilization of IPs as integral detectors in practical radiation fields. Empirically, the fading pattern is known to change when the IP is scanned by different types of image readers. The differences in the fading patterns obtained with two types of image readers, the BAS-1000 and the BAS-5000 (Fuji Film Co.), is discussed. Development of an ...

  18. Comparison of lead zirconate titanate thin films for microelectromechanical energy harvester with interdigitated and parallel plate electrodes.

    Science.gov (United States)

    Chidambaram, Nachiappan; Mazzalai, Andrea; Balma, Davide; Muralt, Paul

    2013-08-01

    Lead zirconate titanate (PZT) thin films on insulator- buffered silicon substrates with interdigitated electrodes (IDEs) have the potential to harvest more energy than parallel plate electrode (PPE) structures because the former exploit the longitudinal piezoelectric effect, which is about twice as high as the transverse piezoelectric effect used by PPE structures. In this work, both options are compared with respect to dielectric, ferroelectric, and piezoelectric properties, leakage currents, and figure of merit (FOM) for energy harvesting. The test samples were silicon beams with {100} PZT thin films in the case of the PPE geometry, and random PZT thin films for the IDE geometry. Both films were obtained by an identical sol-gel route. Almost the same dielectric constants were derived when the conformal mapping method was applied for the IDE capacitor to correct for the IDE geometry. The dielectric loss was smaller in the IDE case. The ferroelectric loops showed a higher saturation polarization, a higher coercive field, and less back-switching for the IDE case. The leakage current density of the IDE structure was measured to be about 4 orders of magnitude lower than that of the PPE structure. The best FOM of the IDE structures was 20% superior to that of the PPE structures while also having a voltage response that was ten times higher (12.9 mV/μ strain).

  19. Improvement of a thermal energy storage using plates with paraffin-graphite composite

    Energy Technology Data Exchange (ETDEWEB)

    Marin, J.M.; Zalba, B. [Universidad da Zaragoza Edificio Betancourt, Zaragoza (Spain). Dpto. Ingenieria Mecanica; Cabeza, L.F. [Universitat de Lleida (Spain). Dpto. d' Informatica i Enginyeria Industrial; Mehling, H. [ZAE Bayern, Garching (Germany). Energy Conversion and Storage

    2005-06-01

    This work aims at designing a thermal energy storage (TES) using air as heat transfer medium, efficient mainly for free-cooling but also for other applications, improving the low heat transfer rates dues to the thermal conductivity of the materials usually employed in these systems, phase change materials (PCM). In this paper, free-cooling means the storage of cold from the night to be used during the day to cool down a room. An experimental set-up has been constructed to simulate the application. The loading and unloading processes (melting and freezing of the PCM) have two disadvantages: a relative long duration, in the range from 3 to 8 h, and a very high power consumption of the fans. Using a porous matrix of graphite where the PCM is embedded, both handicaps can be noticeably overcome. The application is studied, both experimentally and numerically. (Author)

  20. Energy flow and thermal comfort in buildings

    DEFF Research Database (Denmark)

    Le Dreau, Jerome

    insulated buildings (R > 5 m2.K/W). In case of single-storey building with a low level of insulation, the effectiveness of radiant terminals is lower due to the larger back losses, and an air-based terminal might be more energy-efficient than a radiant terminal (in terms of delivered energy). Regarding...... is based on both radiation and convection. Radiant terminals have the advantage of making use of low grade sources (i.e. low temperature heating and high temperature cooling), thus decreasing the primary energy consumption of buildings. But there is a lack of knowledge on the heat transfer from...... beam. The higher the air change rate and the warmer the outdoor air, the larger the savings achieved with a radiant cooling terminals. Therefore radiant terminals have a large potential of energy savings for buildings with high ventilation rates (e.g. shop, train station, industrial storage). Among...

  1. Performance characteristic of thermosyphon heat pipe at radiant heat source

    Science.gov (United States)

    Hrabovský, Peter; Papučík, Štefan; Kaduchová, Katarína

    2016-06-01

    This article discusses about device, which is called heat pipe. This device is with heat source with radiant heat source. Heat pipe is device with high efficiency of heat transfer. The heat pipe, which is describe in this article is termosyphon heat pipe. The experiment with termosyphon heat pipe get a result. On the base of result, it will be in future to create mathematical model in Ansys. Thermosyphon heat pipe is made of copper and distilled water is working fluid. The significance of this experiment consists in getting of the heat transfer and performance characteristic. On the basis of measured and calculated data can be constructed the plots.

  2. Radiant coolers - Theory, flight histories, design comparisons and future applications

    Science.gov (United States)

    Donohoe, M. J.; Sherman, A.; Hickman, D. E.

    1975-01-01

    Radiant coolers have been developed for application to the cooling of infrared detectors aboard NASA earth observation systems and as part of the Defense Meteorological Satellite Program. The prime design constraints for these coolers are the location of the cooler aboard the satellite and the satellite orbit. Flight data from several coolers indicates that, in general, design temperatures are achieved. However, potential problems relative to the contamination of cold surfaces are also revealed by the data. A comparison among the various cooler designs and flight performances indicates design improvements that can minimize the contamination problem in the future.

  3. Luz Pozo Garza: Memoria radiante de una mujer solar

    OpenAIRE

    Blanco, Carmen

    2006-01-01

    The poetry of Luz Poz Garza is a Platonic flashing beauty cosmos ruled by clarity, depth and harmony symbolized in the name that gave birth to it: that of a “solar woman”, fully self-assured in her life and in her work, gathered in the “heart of light” of her poetry. Memoria solar, the title of her complete poetry work, contains the radiant memory of the solar woman, a curved by plenitude cosmos that shelters a first microcosmos (that of her youth poetry), red fruit such as orange o meat appl...

  4. A Study on a Perfaormance of Water-Spray-Type Ice Thermal Energy Storage Vessel with Vertical Heat Exchange Plates

    Science.gov (United States)

    Yoshimura, Kenji; Koyama, Shigeru; Fukuda, Toshihito; Ohba, Hideki

    A system with a water -embedded-type ice storage vessel is widely used because of its simple structure compactness. However, this ice storage vessel has a disadvantage, that is, the melting rate is very small. The use of falling water film seems to be one of promising ways for solving this disadvantage. We have found in our previous study that the use of the falling water film is very effective, especially for high initial water temperatures. In the present study, we examined the melting performance of a falling-water-film-type ice thermal energy storage vessel with practical size, having vertical heat exchange plates. The results obtained are as follows : the quantity of melting ice increases with increase of the water film flow rate, the melting rate decreases with time because ice surface are decreases with time gradually, the heat transfer coefficient of melting increases with increase of the water film flow rate, and the melting rate increases with increase of the water-spray temperature.

  5. 16 CFR Figure 10 to Subpart A of... - Insulation Radiant Panel Test Data Log Format

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Insulation Radiant Panel Test Data Log Format 10 Figure 10 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION.... 1209, Subpt. A, Fig. 10 Figure 10 to Subpart A of Part 1209—Insulation Radiant Panel Test Data...

  6. Testing and thermal modeling of radiant panels systems as commissioning tool

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca Diaz, Nestor, E-mail: njfonseca@doct.ulg.ac.b [University of Liege Belgium, Thermodynamics Laboratory, Campus du Sart Tilman, Bat: B49, P33, B-4000 Liege (Belgium); Universidad Tecnologica de Pereira, Facultad de Ingenieria Mecanica, AA 97 Pereira (Colombia); Cuevas, Cristian [Universidad de Concepcion, Facultad de Ingenieria, Departamento de Ingenieria Mecanica, Casilla 160c Concepcion (Chile)

    2010-12-15

    This paper presents the results of a study performed to develop a thermal modeling of radiant panels systems to be used in situ, as diagnosis tool in commissioning processes to determine the main operating conditions of the system in cooling or heating mode. The model considers the radiant panels as a finned heat exchanger in dry regime. By using as inputs the ceiling and room dimensions, the radiant ceiling material properties and the measurements of air and water mass flow rates and temperatures, the model is able to calculate the radiant ceiling capacity, ceiling surface average temperature, water exhaust temperature and resultant temperature as a comfort indicator. The modeling proposed considers combined convection, perforation effect and a detailed radiative heat exchange method for radiant ceiling systems. An example of each system considered in this study is shown, illustrating the validation of the model. A sensitive analysis of the model is performed.

  7. Finite-elements modeling of radiant heat transfers between mobile surfaces; Modelisation par elements finis de transferts radiatifs entre surfaces mobiles

    Energy Technology Data Exchange (ETDEWEB)

    Daurelle, J.V.; Cadene, V.; Occelli, R. [Universite de Provence, 13 - Marseille (France)

    1996-12-31

    In the numerical modeling of thermal industrial problems, radiant heat transfers remain difficult to take into account and require important computer memory and long computing time. These difficulties are enhanced when radiant heat transfers are coupled with finite-elements diffusive heat transfers because finite-elements architecture is complex and requires a lot of memory. In the case of radiant heat transfers along mobile boundaries, the methods must be optimized. The model described in this paper concerns the radiant heat transfers between diffuse grey surfaces. These transfers are coupled with conduction transfers in the limits of the diffusive opaque domain. 2-D and 3-D geometries are analyzed and two configurations of mobile boundaries are considered. In the first configuration, the boundary follows the deformation of the mesh, while in the second, the boundary moves along the fixed mesh. Matter displacement is taken into account in the term of transport of the energy equation, and an appropriate variation of the thermophysical properties of the transition elements between the opaque and transparent media is used. After a description of the introduction of radiative limit conditions in a finite-elements thermal model, the original methods used to optimize calculation time are explained. Two examples of application illustrate the approach used. The first concerns the modeling of radiant heat transfers between fuel rods during a reactor cooling accident, and the second concerns the study of heat transfers inside the air-gap of an electric motor. The method of identification of the mobile surface on the fixed mesh is described. (J.S.) 12 refs.

  8. Tunnel effect wave energy detection

    Science.gov (United States)

    Kaiser, William J. (Inventor); Waltman, Steven B. (Inventor); Kenny, Thomas W. (Inventor)

    1995-01-01

    Methods and apparatus for measuring gravitational and inertial forces, magnetic fields, or wave or radiant energy acting on an object or fluid in space provide an electric tunneling current through a gap between an electrode and that object or fluid in space and vary that gap with any selected one of such forces, magnetic fields, or wave or radiant energy acting on that object or fluid. These methods and apparatus sense a corresponding variation in an electric property of that gap and determine the latter force, magnetic fields, or wave or radiant energy in response to that corresponding variation, and thereby sense or measure such parameters as acceleration, position, particle mass, velocity, magnetic field strength, presence or direction, or wave or radiant energy intensity, presence or direction.

  9. Experimental and theoretical development of a thermal design tool for radiant domestic stoves. Paper no. IGEC-1-003

    Energy Technology Data Exchange (ETDEWEB)

    Ghaddar, N. [American Univ. of Beirut, Dept. of Mechanical Engineering, Beirut (Lebanon)]. E-mail: farah@aub.edu.lb; Ghali, K. [Beirut Arab Univ., Beirut (Lebanon)]. E-mail: amro@aub.edu.lb; Salam, M. [American Univ. of Beirut, Dept. of Mechanical Engineering, Beirut (Lebanon)

    2005-07-01

    A steady-state space radiant heat model and a stove combustion model are developed to simulate the heat exchanges between various surfaces in the room and the stove and stack surfaces, assuming stiochiometric combustion inside the stove and the exhaust gases flow out through the stack by natural convection. The space heat model calculates the fuel consumption, the stove, stack temperatures, and the mass flow rate of exhaust gases, and provides an opportunity to study energy efficiency of stove, while satisfying the constraints of thermal comfort. Fanger (1982) model and a radiation exchange model between various surfaces of the space, the thermal building energy balance, and stove combustion process is applied to determine the mean radiant temperature (MRT) and the extent of thermal comfort as determined by predicted mean vote (PMV). The overall model is validated by performing experiments in a room placed inside controlled outdoor environment. The room is heated using a common domestic stove for rural areas of Lebanon. The measured MRT, the average room temperature, the wall surfaces temperatures agreed within {+-}7% of values predicted by the numerical model. A parametric study using the developed models reveals that the values of MRT and PMV depend strongly on the position of the radiant stove heater and stack with respect to the cold window and the occupant location. It is shown that it is possible to save up to 15% in fuel consumption of the stove by changing the stove position in the room with respect to the window and to the person, while maintaining the same level of comfort. (author)

  10. Evaluation of Various Retrofitting Concepts of Building Envelope for Offices Equipped with Large Radiant Ceiling Panels by Dynamic Simulations

    Directory of Open Access Journals (Sweden)

    Sabina Jordan

    2015-09-01

    Full Text Available In order to achieve significant savings in energy and an improved level of thermal comfort in retrofitted existing buildings, specific retrofitting concepts that combine new technologies and design need to be developed and implemented. Large radiant surfaces systems are now among the most promising future technologies to be used both in retrofitted and in new low-energy buildings. These kinds of systems have been the topic of several studies dealing with thermal comfort and energy utilization, but some specific issues concerning their possible use in various concepts for retrofitting are still poorly understood. In the present paper, some results of dynamic simulations, with the transient system simulation tool (TRNSYS model, of the retrofitted offices equipped with radiant ceiling panels are presented and thoroughly analysed. Based on a precise comparison of the results of these simulations with actual measurements in the offices, certain input data for the model were added, so that the model was consequently validated. The model was then applied to the evaluation of various concepts of building envelopes for office retrofitting. By means of dynamic simulations of indoor environment it was possible to determine the benefits and limitations of individual retrofitting concepts. Some specific parameters, which are relevant to these concepts, were also identified.

  11. Radiant-and-plasma technology for coal processing

    Directory of Open Access Journals (Sweden)

    Vladimir Messerle

    2012-12-01

    Full Text Available Radiant-and-plasma technology for coal processing is presented in the article. Thermodynamic computation and experiments on plasma processing of bituminous coal preliminary electron-beam activated were fulfilled in comparison with plasma processing of the coal. Positive influence of the preliminary electron-beam activation of coal on synthesis gas yield was found. Experiments were carried out in the plasma gasifier of 100 kW power. As a result of the measurements of material and heat balance of the process gave the following integral indicators: weight-average temperature of 2200-2300 K, and carbon gasification degree of 82,4-83,2%. Synthesis gas yield at thermochemical preparation of raw coal dust for burning was 24,5% and in the case of electron-beam activation of coal synthesis gas yield reached 36,4%, which is 48% higher.

  12. Luz Pozo Garza: Memoria radiante de una mujer solar

    Directory of Open Access Journals (Sweden)

    Blanco, Carmen

    2006-08-01

    Full Text Available The poetry of Luz Poz Garza is a Platonic flashing beauty cosmos ruled by clarity, depth and harmony symbolized in the name that gave birth to it: that of a “solar woman”, fully self-assured in her life and in her work, gathered in the “heart of light” of her poetry. Memoria solar, the title of her complete poetry work, contains the radiant memory of the solar woman, a curved by plenitude cosmos that shelters a first microcosmos (that of her youth poetry, red fruit such as orange o meat apple, and a second microcosmos (that of her maturity poetry of white or blue flower of total mystic lucidity, such as solar camellia, rose o lotus.La poesía de Luz Pozo Garza es un cosmos fulgurante de belleza platónica regida por la claridad, la profundidad y la armonía simbolizadas en el nombre que lo dio a luz, el de una “mujer solar” plenamente autoafirmada en su vida y en su obra, unidas en el “corazón de Luz” de su poesía. Memoria solar, el título de su obra poética completa contiene su memoria radiante de mujer solar, un cosmos curvo de plenitud que guarda un microcosmos primero, el de su poesía de juventud, de fruto rojo, cual naranja o manzana de la carne, y un microcosmos segundo, el de su poesía de madurez, de flor blanca o azul de la total lucidez mística, cual camelia, rosa o loto solares.

  13. Study on transportation plate energy saving goals of Shenhua group%神华集团运输板块节能目标研究

    Institute of Scientific and Technical Information of China (English)

    张淑英; 蔡先锋

    2011-01-01

    神华集团的运输板块业务主要包括铁路和港口两部分,运输板块耗能结构主要由一次能源——石油、天然气、煤,以及二次能源——电构成.根据国家节能减排的相关政策、铁道部及交通运输部的相关规划和措施,基于基准情景、低参考情景和高参考情景,研究了神华集团运输板块2015年与2020年两个时间点的节能目标.%Transportation plate of Shenhua group is divided into railway transportation and harbor transportation and the energy consumption is made up of primary engergy including petroleum, nature gas and coal and secondary energy including electrical energy. According to the national policies, plannings and measures involved energy saving and emission reduction, based on the analyses of baseline scenario, the low referance scenario and the high reference scenario, the transportation plate energy saving goals of Shenhua group on 2015 and 2020 are studied.

  14. A system for the comparison of tools for the simulation of water-based radiant heating and cooling systems

    DEFF Research Database (Denmark)

    Behrendt, Benjamin; Raimondo, Daniela; Zhang, Ye;

    2011-01-01

    increase of water based radiant systems in modern buildings and a need for reliable simulation tools to predict the indoor environment and energy performance. This paper describes the comparison of the building simulation tools IDA ICE, IES , EnergyPlus and TRNSYS. The simulation tools are compared to each......Low temperature heating and high temperature cooling systems such as thermally activated building systems (TABS) offer the chance to use low exergy sources, which can be very beneficial financially as well as ecologically when using renewable energy sources. The above has led to a considerable...... other using the same room and boundary conditions. The results show significant differences in predicted room temperatures, heating and cooling degree hours as well as thermal comfort in winter and summer....

  15. Bone splint technique and plating application in adolescent high-energy comminuted fracture of distal femur with bone defects

    Institute of Scientific and Technical Information of China (English)

    LIU Hui; DING Zhen-qi; ZHAI Wen-liang; KANG Liang-qi; YAO Xiao-tao

    2008-01-01

    @@ Comminuted fracture of distal femur is a common lower limb injury from traffic accidents, especially from motor accidents. Routine dynamic condylar screw ( DCS ) or 95-degree condylar plate ( CP ) sometimes cannot solve the bone defect in the center of alignment and contralateral diaphysis for the reason of absent screw anchor point, especially for AO C2. 2-2. 3 types.

  16. Standardized performance tests of collectors of solar thermal energy - A flat-plate copper collector with parallel mylar striping

    Science.gov (United States)

    Johnson, S. M.

    1976-01-01

    Basic test results are reported for a flat plate solar collector whose performance was determined in a solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and one coolant flow rate. Collector efficiency is correlated in terms of inlet temperature and flux level.

  17. An experimental study of thermal comfort at different combinations of air and mean radiant temperature

    DEFF Research Database (Denmark)

    Simone, Angela; Olesen, Bjarne W.

    2009-01-01

    , a lower air temperature is preferred. This paper presents an experimental study with 30 human subjects exposed to three different combinations of air- and mean radiant temperature with an operative temperature around 23 °C. The subjects gave subjective evaluations of thermal comfort and perceived air...... quality during the experiments. The PMV-index gave a good estimation of thermal sensation vote (TSV) when the air and mean radiant temperature were the same. In the environment with different air- and mean radiant temperatures, a thermal comfort evaluation shows an error up to 1 scale unit on the 7-point...... thermal sensation scale. The study could not confirm any preference regarding air and mean radiant temperature....

  18. Thermal Conditions in a Simulated Office Environment with Convective and Radiant Cooling Systems

    DEFF Research Database (Denmark)

    Mustakallio, Panu; Bolashikov, Zhecho Dimitrov; Kostov, Kalin

    2013-01-01

    ventilation (MVRC). CB was based on convection cooling while the remaining three systems (CBR, CCMV and MVRC) on combined radiant and convective cooling. Measurements were performed in design (64 W/m2) and usual (38 W/m2) cooling conditions. Air temperature, operative temperature, radiant asymmetry, air......The thermal conditions in a two person office room were measured with four air conditioning systems: chilled beam (CB), chilled beam with radiant panel (CBR), chilled ceiling with ceiling installed mixing ventilation (CCMV) and four desk partition mounted local radiant cooling panels with mixing...... velocity and turbulent intensity were measured and draft rate levels calculated in the room. Manikin-based equivalent temperature (MBET) was determined by two thermal manikins to identify the impact of the local thermal conditions generated by the studied systems on occupants’ thermal comfort. The results...

  19. General Relativistic Radiant Shock Waves in the Post-Quasistatic Approximation

    Energy Technology Data Exchange (ETDEWEB)

    H, Jorge A Rueda [Centro de Fisica Fundamental, Universidad de Los Andes, Merida 5101, Venezuela Escuela de Fisica, Universidad Industrial de Santander, A.A. 678, Bucaramanga (Colombia); Nunez, L A [Centro de Fisica Fundamental, Universidad de Los Andes, Merida 5101, Venezuela Centro Nacional de Calculo Cientifico, Universidad de Los Andes, CeCalCULA, Corporacion Parque Tecnologico de Merida, Merida 5101, Venezuela (Venezuela)

    2007-05-15

    An evolution of radiant shock wave front is considered in the framework of a recently presented method to study self-gravitating relativistic spheres, whose rationale becomes intelligible and finds full justification within the context of a suitable definition of the post-quasistatic approximation. The spherical matter configuration is divided into two regions by the shock and each side of the interface having a different equation of state and anisotropic phase. In order to simulate dissipation effects due to the transfer of photons and/or neutrinos within the matter configuration, we introduce the flux factor, the variable Eddington factor and a closure relation between them. As we expected the strong of the shock increases the speed of the fluid to relativistic ones and for some critical values is larger than light speed. In addition, we find that energy conditions are very sensible to the anisotropy, specially the strong energy condition. As a special feature of the model, we find that the contribution of the matter and radiation to the radial pressure are the same order of magnitude as in the mant as in the core, moreover, in the core radiation pressure is larger than matter pressure.

  20. Energy efficient heating and ventilation of large halls

    CERN Document Server

    Hojer, Ondrej; Kabele, Karel; Kotrbaty, Miroslav; Sommer, Klaus; Petras, Dusan

    2011-01-01

    This guidebook is focused on modern methods for design, control and operation of energy efficient heating systems in large spaces and industrial halls. The book deals with thermal comfort, light and dark gas radiant heaters, panel radiant heating, floor heating and industrial air heating systems. Various heating systems are illustrated with case studies. Design principles, methods and modeling tools are presented for various systems.

  1. Numerical evaluation of the thermal performances of roof-mounted radiant barriers

    OpenAIRE

    Miranville, Frédéric; Boyer, Harry; Lucas, Franck; Johan, Seriacaroupin

    2014-01-01

    International audience; This paper deals with the thermal performances of roof-mounted radiant barriers. Using dynamic simulations of a mathematical model of a whole test cell including a radiant barrier installed between the roof top and the ceiling, the thermal performance of the roof is calculated. The mean method is more particularly used to assess the thermal resistance of the building component and lead to a value which is compared to the one obtained for a mass insulation product such ...

  2. Radiant Cooling for Closed-Loop Water Containment: Exploration of Possible Application in Dry Docks

    Science.gov (United States)

    2015-08-20

    Radiant Cooling For Closed-Loop Water Containment: Exploration of Possible Application in Dry Docks by Trevor R. Murphy, Mechanical...Organization: SPAWAR Sponsoring Organization: NESDI Keywords: Dry Dock Cooling, Heat Transfer, Closed Loop, Pipe System, Cost, Pareto List of Programs...provide data for estimating the cost of implementing a closed-loop radiant cooling system for ships in dry docks . Depending on the material used, pipe

  3. Heat transfers in porous media. Conduction, convection, radiant transfer; Transferts de chaleur dans les milieux poreux. Conduction, convection, rayonnement

    Energy Technology Data Exchange (ETDEWEB)

    Bories, S.; Mojtabi, A.; Prat, M.; Quintard, M. [Institut de Mecanique des Fluides de Toulouse, 31 (France)

    2008-10-15

    Multiple physico-chemical and transport phenomena take place in porous media. The study of these phenomena requires the knowledge of fluid storage, transfer and mechanical properties of these media. Like all polyphasic heterogenous systems, these properties depend on the morphology of the matrix and of the phenomena interacting in the different phases. This makes the heat transfers in porous media a particularly huge field of researches. This article makes a synthesis of these researches. Content: 1 - classification and characterization of porous media; 2 - modeling of transfer phenomena; 3 - heat transfer by conduction: concept of equivalent thermal conductivity (ETC), modeling of conduction heat transfer, ETC determination; 4 - heat transfer by convection: modeling of convection heat transfer, natural convection (in confined media, along surfaces or impermeable bodies immersed in a saturated porous medium), forced and mixed convection; 5 - radiant heat transfer: energy status equation, approximate solutions of the radiant transfer equation, use of the approximate solutions: case of fibrous insulating materials; 6 - conclusion. (J.S.)

  4. Radiant heat increases piglets’ use of the heated creep area on the critical days after birth

    DEFF Research Database (Denmark)

    Larsen, Mona Lilian Vestbjerg; Thodberg, Karen; Pedersen, Lene Juul

    2017-01-01

    The aim of the present study was to investigate how piglets’ use of a creep area is affected by using radiant heat compared to an incandescent light bulb. It was hypothesised that radiant heat would increase the use of the creep area. Twenty litters were randomly assigned to one of two heat sources...... in the creep area: (1) an incandescent light bulb (STANDARD, n=10) or (2) a radiant heat source (RADIANT, n=10) with five of each type of heat source in each of two batches. Observations on piglets’ position in the pen were made by scan sampling every ten minutes in a 4-hour period from 1100 to 1500 h on day 1......–7, 14 and 21 post partum. A higher percentage of piglets in the creep area was seen for RADIANT litters compared to STANDARD litters on day 2 (P=0.002) and day 3 (P=0.005), and percentage of piglets in the creep area increased for RADIANT litters from day 1 to 2 (P

  5. Flightweight radiantly and actively cooled panel: Thermal and structural performance

    Science.gov (United States)

    Shore, C. P.; Nowak, R. J.; Kelly, H. N.

    1982-01-01

    A 2- by 4-ft flightweight panel was subjected to thermal/structural tests representative of design flight conditions for a Mach 6.7 transport and to off-design conditions simulating flight maneuvers and cooling system failures. The panel utilized Rene 41 heat shields backed by a thin layer of insulation to radiate away most of the 12 Btu/ft2-sec incident heating. A solution of ethylene glycol in water circulating through tubes in an aluminum-honeycomb-sandwich panel absorbed the remainder of the incident heating (0.8 Btu/sq ft-sec). The panel successfully withstood (1) 46.7 hr of radiant heating which included 53 thermal cycles and 5000 cycles of uniaxial inplane loading of + or - 1200 lfb/in; (2) simulated 2g-maneuver heating conditions and simulated cooling system failures without excessive temperatures on the structural panel; and (3) the extensive thermal/structural tests and the aerothermal tests reported in NASA TP-1595 without significant damage to the structural panel, coolant leaks, or hot-gas ingress to the structural panel.

  6. Experimental evaluation of the response of micro-channel plate detector to ions with 10s of MeV energies

    Science.gov (United States)

    Jeong, Tae Won; Singh, P. K.; Scullion, C.; Ahmed, H.; Kakolee, K. F.; Hadjisolomou, P.; Alejo, A.; Kar, S.; Borghesi, M.; Ter-Avetisyan, S.

    2016-08-01

    The absolute calibration of a microchannel plate (MCP) assembly using a Thomson spectrometer for laser-driven ion beams is described. In order to obtain the response of the whole detection system to the particles' impact, a slotted solid state nuclear track detector (CR-39) was installed in front of the MCP to record the ions simultaneously on both detectors. The response of the MCP (counts/particles) was measured for 5-58 MeV carbon ions and for protons in the energy range 2-17.3 MeV. The response of the MCP detector is non-trivial when the stopping range of particles becomes larger than the thickness of the detector. Protons with energies E ≳ 10 MeV are energetic enough that they can pass through the MCP detector. Quantitative analysis of the pits formed in CR-39 and the signal generated in the MCP allowed to determine the MCP response to particles in this energy range. Moreover, a theoretical model allows to predict the response of MCP at even higher proton energies. This suggests that in this regime the MCP response is a slowly decreasing function of energy, consistently with the decrease of the deposited energy. These calibration data will enable particle spectra to be obtained in absolute terms over a broad energy range.

  7. 地板辐射采暖系统的研究进展%Research Progress in Floor Radiant Heating System

    Institute of Scientific and Technical Information of China (English)

    黎天标; 秦红

    2016-01-01

    Due to the good thermal comfort and energy saving, the floor radiant heating has become the most popular way of heating. This paper briefly introduces the concept, basic principle and classification of floor radiant heating, and summarizes the achievement obtained in all aspects and the related research at home and abroad in recent years. The paper also described the common approaches of performance and economic evaluation. And the problems of floor radiant heating system are also pointed out. Further optimizations of current floor radiant heating system are needed for future applications of this technology.%地板辐射采暖由于具有良好的热舒适性和节能性,已经成为人们最青睐的采暖方式之一。通过简要介绍地板辐射采暖的概念、基本原理及分类,从地板辐射采暖系统的组成部分综述了近几年来国内外专家学者的相关研究,以及在各个方面取得的成果。概述了目前最常用的地暖系统的性能评价指标和技术经济性评价方法。并指出了地板辐射采暖系统目前存在的各种问题,以及未来需要对现有的系统结构作进一步优化研究,同时,研发出更节能环保的新型地暖系统。

  8. Flat-plate solar array project of the US Department of Energy's National Photovoltaics Program: Ten years of progress

    Science.gov (United States)

    Christensen, Elmer

    1985-01-01

    The Flat-Plate Solar Array (FSA) Project, a Government-sponsored photovoltaics project, was initiated in January 1975 (previously named the Low-Cost Silicon Solar Array Project) to stimulate the development of PV systems for widespread use. Its goal then was to develop PV modules with 10% efficiency, a 20-year lifetime, and a selling price of $0.50 per peak watt of generating capacity (1975 dollars). It was recognized that cost reduction of PV solar-cell and module manufacturing was the key achievement needed if PV power systems were to be economically competitive for large-scale terrestrial use.

  9. 太阳能辐射空调器的研究%On Solar Radiant Air-conditioner

    Institute of Scientific and Technical Information of China (English)

    周亚东; 王军

    2014-01-01

    The paper introduces a solar radiant air-conditioner [1], which supplies heating and cooling for an office hall in one of the colleges in Haikou, Hainan. The system of the solar radiant air-conditioner uses solar water cooler and capillary network. The composition of the system is presented, and the major energy-saving parts of the system and the energy-saving performance ratio of the conventional temperature difference in air conditioning are analyzed from the thermodynamic theory. After running half a year, the system achieved the effects of substantial energy saving and reducing the thermal pollution of the environ-ment from the test data of the indicators. The system has the advantages of low investment and high utiliza-tion rate of the equipments.%介绍一种太阳能辐射空调器[1],为海南省海口市某学院办公事务大厅提供制冷的案例。系统用太阳冷水器与毛细管网相结合,介绍了其系统组成,并用热力学理论分析了本系统各主要节能部分与常规温差空调的节能效能比。系统运行半年,从各项指标检测数据看,取得了大幅节约能源,减少了对环境热污染的效果。该系统初投资少,设备利用率高,对今后的推广有一定的指导作用。

  10. Gamma-ray detection efficiency of the microchannel plate installed as an ion detector in the low energy particle instrument onboard the GEOTAIL satellite.

    Science.gov (United States)

    Tanaka, Y T; Yoshikawa, I; Yoshioka, K; Terasawa, T; Saito, Y; Mukai, T

    2007-03-01

    A microchannel plate (MCP) assembly has been used as an ion detector in the low energy particle (LEP) instrument onboard the magnetospheric satellite GEOTAIL. Recently the MCP assembly has detected gamma rays emitted from an astronomical object and has been shown to provide unique information of gamma rays if they are intense enough. However, the detection efficiency for gamma rays was not measured before launch, and therefore we could not analyze the LEP data quantitatively. In this article, we report the gamma-ray detection efficiency of the MCP assembly. The measured efficiencies are 1.29%+/-0.71% and 0.21%+/-0.14% for normal incidence 60 and 662 keV gamma rays, respectively. The incident angle dependence is also presented. Our calibration is crucial to study high energy astrophysical phenomena by using the LEP.

  11. The high surface energy of NiO {110} facets incorporated into TiO2 hollow microspheres by etching Ti plate for enhanced photocatalytic and photoelectrochemical activity

    Science.gov (United States)

    Li, Jian; Cui, Hongzhi; Song, Xiaojie; Wei, Na; Tian, Jian

    2017-02-01

    We present a rational design for the controllable synthesis of NiO/TiO2 hollow microspheres (NTHMs) with Ti plate via a one-pot template-free synthesis strategy. Specifically, to enhance the formation of hollow microspheres, part of the titanium source is provided by the Ti plate. The hollow spherical NiO/TiO2 particles possess unique microstructural characteristics, namely, a higher specific surface area (∼65.82 m2 g-1), a larger mesoporous structure (∼7.79 nm), and hierarchical nanoarchitectures connected with mesopores within the shell (monodispersed size of ∼1 μm and shell thickness of ∼80 nm). In addition, as a cocatalyst for improved catalytic activity, the incorporated NiO nanoparticles with exposed high surface energy {110} facets displayed an outstanding performance. It has been proven that this facile nanostructure possesses remarkably high photoelectrochemical and photocatalytic activities. The main mechanism for enhancement of photocatalytic activity is attributed to the construction of p-n junctions with an inner electric field between TiO2 and NiO, which can dramatically enhance the separation efficiency of the photogenerated electron-hole pairs. This strategy could be applied to fabricate mixed metal oxide hollow microspheres toward the photoelectrochemical catalysis.

  12. High energy X-ray diffraction measurement of residual stresses in a monolithic aluminum clad uranium-10 wt% molybdenum fuel plate assembly

    Science.gov (United States)

    Brown, D. W.; Okuniewski, M. A.; Almer, J. D.; Balogh, L.; Clausen, B.; Okasinski, J. S.; Rabin, B. H.

    2013-10-01

    Residual stresses are expected in monolithic, aluminum clad uranium 10 wt% molybdenum (U-10Mo) nuclear fuel plates because of the large mismatch in thermal expansion between the two bonded materials. The full residual stress tensor of the U-10Mo foil in a fuel plate assembly was mapped with 0.1 mm resolution using high-energy (86 keV) X-ray diffraction. The in-plane stresses in the U-10Mo foil are strongly compressive, roughly -250 MPa in the longitudinal direction and -140 MPa in the transverse direction near the center of the fuel foil. The normal component of the stress is weakly compressive near the center of the foil and tensile near the corner. The disparity in the residual stress between the two in-plane directions far from the edges and the tensile normal stress suggest that plastic deformation in the aluminum cladding during fabrication by hot isostatic pressing also contributes to the residual stress field. A tensile in-plane residual stress is presumed to be present in the aluminum cladding to balance the large in-plane compressive stresses in the U-10Mo fuel foil, but cannot be directly measured with the current technique due to large grain size.

  13. Scanning electron microscopy and energy-dispersive X-ray microanalysis studies of early dental calculus on resin plates exposed to human oral cavities.

    Science.gov (United States)

    Kodaka, T; Ohohara, Y; Debari, K

    1992-06-01

    Dental calculus formed after 10 days on resin plates, applied to the lingual sides of the mandibular gingival regions in eight human subjects, was investigated by means of scanning electron microscopy (SEM) and energy-dispersive X-ray microanalysis (EDX). The mineral deposits were mainly divided into three types: A, B, and C. The type A deposits showing an average Ca/P molar ratio of 1.42 were densely packed with fine needle-shaped crystals formed by the intra- and extra-cellular calcification. The type A deposits, probably composed of Ca-deficient apatites and the transitional forms between apatite and octacalcium phosphate (OCP), were observed in all subjects. The type B deposits showing an average Ca/P molar ratio of 0.96 were aggregated with polygonal column, triangular plate-shaped, and rhombohedral crystals. These crystals identified as brushite (CaHPO4-2H2O:dicalcium phosphate dihydrate: DCPD) were found in four subjects. Platelet-shaped crystals of the type C deposits were observed in three subjects. Their Ca/P molar ratio of 1.26 and the crystal shape were similar to those of OCP. Whitlockite crystals were not found although Mg-containing hexagonal disk-like crystals were observed in two subjects.

  14. Water loss from the skin of term and preterm infants nursed under a radiant heater.

    Science.gov (United States)

    Kjartansson, S; Arsan, S; Hammarlund, K; Sjörs, G; Sedin, G

    1995-02-01

    The rate of evaporation from the skin (g/m2/h) was measured in 12 full-term and 16 preterm infants (gestational age 25-34 wk) both during incubator care and when nursed under a radiant heater. The method for evaporation rate measurement is noninvasive and based on determination of the water vapor pressure gradient close to the skin surface. Measurements were first made with the infant nursed in an incubator with a controlled environment with respect to humidity, temperature, and air velocity. The measurements in the term infants were performed at an ambient relative humidity (RH) of 50%, and in the preterm infants first at 50% and subsequently at 30-40%. Evaporation rate was then measured with the infant nursed under a radiant heater. In term infants, mean evaporation rate was 3.3 g/m2/h during incubator care (RH 50%) and 4.4 g/m2/h during care under the radiant heater. In preterm infants, the corresponding values were 15.5 g/m2/h in the incubator at RH 50%, 16.7 g/m2/h at RH 30-40%, and 17.9 g/m2/h under the radiant heater. It is concluded that the evaporative water loss from the skin depends on the ambient water vapor pressure, irrespective of whether the infant is nursed in an incubator or under a radiant heater. The higher rate of evaporation during care under a radiant heater is due to the lower ambient water vapor pressure and not to any direct effect of the nonionizing radiation on the skin.

  15. Energy flow and thermal comfort in buildings

    DEFF Research Database (Denmark)

    Le Dreau, Jerome

    the terminal towards the space and on the parameters influencing the effectiveness of terminals. Therefore the comfort conditions and energy consumption of four types of terminals (active chilled beam, radiant floor, wall and ceiling) have been compared for a typical office room, both numerically...... beam. The higher the air change rate and the warmer the outdoor air, the larger the savings achieved with a radiant cooling terminals. Therefore radiant terminals have a large potential of energy savings for buildings with high ventilation rates (e.g. shop, train station, industrial storage). Among...... comfort, a similar global level has been observed for the radiant and air-based terminals in both numerical and experimental investigations. But the different terminals did not achieve the same uniformity in space. The active chilled beam theoretically achieves the most uniform comfort conditions (when...

  16. Monte Carlo simulation of the radiant field produced by a multiple-lamp quartz heating system

    Science.gov (United States)

    Turner, Travis L.

    1991-01-01

    A method is developed for predicting the radiant heat flux distribution produced by a reflected bank of tungsten-filament tubular-quartz radiant heaters. The method is correlated with experimental results from two cases, one consisting of a single lamp and a flat reflector and the other consisting of a single lamp and a parabolic reflector. The simulation methodology, computer implementation, and experimental procedures are discussed. Analytical refinements necessary for comparison with experiment are discussed and applied to a multilamp, common reflector heating system.

  17. A novel radiant source for infrared calibration by using a grooved surface

    Institute of Scientific and Technical Information of China (English)

    Hong Zhang; Jingmin Dai

    2006-01-01

    @@ A radiant source with a large aperture at 5-95 ℃ in the wavelength bands of 8-12μm for calibrating infrared imaging systems has been designed. The effective emissivity of its flat bottom with concentric V-grooves was evaluated by the Monte-Carlo method whose correctness was tested and accuracy was discussed. The structure of the source was completed by incorporating the simulation results with the blackbody cavity effect. The source was certificated via an optical measurement system. The source can provide a consistent radiant flux with temperature uniformity of ±0.1 ℃ over an area of diameter of φ80 mm.

  18. Inspection of radiant heating floor applying non-destructive testing techniques: GPR and IRT

    OpenAIRE

    Susana Lagüela-López; Mercedes Solla-Carracelas; Lucía Díaz-Vilariño; Julia Armesto-González

    2015-01-01

    La inspección de suelos radiantes requiere el uso de técnicas no destructivas, tratando de minimizar el impacto de la inspección, así como el tiempo y el coste, además de maximizar la información adquirida de cara al mejor diagnóstico posible. Con este objetivo, la aplicación de termografía infrarroja (IRT) y georradar (GPR) se propone para la inspección de suelos radiantes con cobertura de diferentes materiales, para evaluar las capacidades y la información adquirible con cada técnica. Los r...

  19. Use of local convective and radiant cooling at warm environment: effect on thermal comfort and perceived air quality

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Duszyk, Marcin; Krejcirikova, Barbora

    2012-01-01

    The effect of four local cooling devices (convective, radiant and combined) on thermal comfort and perceived air quality reported by 24 subjects at 28 ˚C and 50% RH was studied. The devices studied were: (1) desk cooling fan, (2) personalized ventilation providing clean air, (3) two radiant panels...

  20. Optics and materials research for controlled radiant energy transfer in energy efficient buildings

    Energy Technology Data Exchange (ETDEWEB)

    Goldner, R.B.; Haas, T.E.

    1990-01-01

    During the past year important progress has been made in regard to uncovering and solving several key problems with respect to developing a lithium-based, monolithic, completely inorganic, reflectivity-modulating, robust electronic window to the point where its technology transfer can be smoothly accomplished. The major problems remaining to be solved are: (a) develop a counterelectrode layer which, as part of the multilayer window structure, is optically and electrochemically satisfactory; (b) develop an optically transparent lithium ion/water vapor blocking layer to prevent the irreversible loss of lithium; (c) develop an optically transparent capping layer; and (d) develop a recipe(s) necessary to obtain robust prototype electrochromic windows by a production-worthy process, such as reactive magnetron sputtering. 1 tab.

  1. Experimental characterization of a radiant porous burner for low temperatures using natural gas; Caracterizacao experimental de um queimador poroso radiante a gas natural para baixas temperaturas

    Energy Technology Data Exchange (ETDEWEB)

    Catapan, Rafael C.; Hissanaga, Newton Junior; Pereira, Fernando M.; Oliveira Junior, Amir A.M. de [Universidade Federal de Santa Catarina (UFSC), Florianopolis, SC (Brazil). Dept. de Engenharia Mecanica; Serfaty, Ricardo [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas (CENPES); Freire, Luiz G.M. [PETROBRAS - RedeGasEnergia, RJ (Brazil)

    2004-07-01

    This article describes the experimental characterization of a radiant porous burner for temperatures between 500 deg C and 900 deg C. These low temperature radiant burners can be used in many practical applications as drying of paper and wood, plastic coating, food cooking and ambient heating. Two different configurations of silicon carbide porous ceramic foams were tested: one with a radian reflecting region (RRR) at the outlet and another without this region. Both configurations were able to sustain the reaction with equivalent ratio under 0,35. The configuration with a reflecting region was able to sustain flames with a minimum power of 60 kW/m{sup 2} and the other configuration with 100 W/m{sup 2}.The configuration with the RRR reached minimum superficial temperatures about 100 deg C lower than the other one. These results show that the reflecting region increases the heat recirculation inside the porous burner. The radiant efficiency varied from 20% to 35% for both burners. (author)

  2. The total spectral radiant flux calibration using a spherical spectrometer at National Institute of Metrology China

    Science.gov (United States)

    Zhao, Weiqiang; Liu, Hui; Liu, Jian

    2016-11-01

    At present day, in the field of lighting the incandescent lamps are phasing out. The solid state lighting products, i.e. LED, and the related market are developing very fast in China for its promising application, due to the energy-saving and the colorful features. For the quality control and the commercial trade purpose, it is highly necessary to measure the optical parameters of LED light sources with a fast, easy and affordable facility. Therefore, more test labs use the spherical spectrometer to measure LED. The quasi- monochrome of LED and the V(lambda) of silicon photodetector mismatch problem is reduced or avoided, because the total spectral radiant flux (TSRF) is measured, and all the optical parameters are calculate from the TSRF. In such a way, the spherical spectrometer calibration requires TSRF standard lamps instead of the traditional total flux standard lamps. National Institute of Metrology China (NIM) has studied and developed the facilities for TSRF measurement and provides related calibration services. This paper shows the TSRF standard lamp calibration procedure using a spherical spectrometer in every-day calibration and its traceable link to the primary SI unit at NIM. The sphere is of 1.5 m diameter, and installed with a spectrometer and a silicon photodetector. It also shows the detail of data process, such as the spectral absorption correction method and the calculation of the result derived from the spectral readings. The TSRF calibration covers the spectra range of 350 nm to 1050 nm, with a measurement uncertainty of 3.6% 1.8% (k=2).

  3. An efficient rectangular plate element

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A new 12-parameter rectangular plate element is presented by useof the double set parameter method. The error in the energy norm is of order O(h2), one order higher than the commonly used Adini nonconforming element.

  4. Theoretical analysis of interferometer wave front tilt and fringe radiant flux on a rectangular photodetector.

    Science.gov (United States)

    Smith, Robert; Fuss, Franz Konstantin

    2013-09-06

    This paper is a theoretical analysis of mirror tilt in a Michelson interferometer and its effect on the radiant flux over the active area of a rectangular photodetector or image sensor pixel. It is relevant to sensor applications using homodyne interferometry where these opto-electronic devices are employed for partial fringe counting. Formulas are derived for radiant flux across the detector for variable location within the fringe pattern and with varying wave front angle. The results indicate that the flux is a damped sine function of the wave front angle, with a decay constant of the ratio of wavelength to detector width. The modulation amplitude of the dynamic fringe pattern reduces to zero at wave front angles that are an integer multiple of this ratio and the results show that the polarity of the radiant flux changes exclusively at these multiples. Varying tilt angle causes radiant flux oscillations under an envelope curve, the frequency of which is dependent on the location of the detector with the fringe pattern. It is also shown that a fringe count of zero can be obtained for specific photodetector locations and wave front angles where the combined effect of fringe contraction and fringe tilt can have equal and opposite effects. Fringe tilt as a result of a wave front angle of 0.05° can introduce a phase measurement difference of 16° between a photodetector/pixel located 20 mm and one located 100 mm from the optical origin.

  5. Theoretical Analysis of Interferometer Wave Front Tilt and Fringe Radiant Flux on a Rectangular Photodetector

    Directory of Open Access Journals (Sweden)

    Franz Konstantin Fuss

    2013-09-01

    Full Text Available This paper is a theoretical analysis of mirror tilt in a Michelson interferometer and its effect on the radiant flux over the active area of a rectangular photodetector or image sensor pixel. It is relevant to sensor applications using homodyne interferometry where these opto-electronic devices are employed for partial fringe counting. Formulas are derived for radiant flux across the detector for variable location within the fringe pattern and with varying wave front angle. The results indicate that the flux is a damped sine function of the wave front angle, with a decay constant of the ratio of wavelength to detector width. The modulation amplitude of the dynamic fringe pattern reduces to zero at wave front angles that are an integer multiple of this ratio and the results show that the polarity of the radiant flux changes exclusively at these multiples. Varying tilt angle causes radiant flux oscillations under an envelope curve, the frequency of which is dependent on the location of the detector with the fringe pattern. It is also shown that a fringe count of zero can be obtained for specific photodetector locations and wave front angles where the combined effect of fringe contraction and fringe tilt can have equal and opposite effects. Fringe tilt as a result of a wave front angle of 0.05° can introduce a phase measurement difference of 16° between a photodetector/pixel located 20 mm and one located 100 mm from the optical origin.

  6. 16 CFR Figure 3 to Subpart A of... - Flooring Radiant Tester Schematic Side Elevation

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Flooring Radiant Tester Schematic Side Elevation 3 Figure 3 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS INTERIM SAFETY STANDARD FOR CELLULOSE INSULATION The Standard Pt...

  7. Total spectral radiant flux measurements on Xe excimer lamps from 115 nm to 1000 nm

    Science.gov (United States)

    Trampert, Klaus E.; Paravia, Mark; Daub, Rüdiger; Heering, Wolfgang

    2007-06-01

    Xe excimer lamps are used as VUV source for industrial application like surface cleaning. To determine the VUV efficiency of the lamp the radiant flux need to be known. Due to the difficulties of VUV measurements, it is often determined by interpolation from a value of a fixed angle, which results in large uncertainties. Here a goniometric setup is presented to measure the radiant flux of VUV sources like Xe excimer lamps which emit a narrow spectral band in the VUV range between λ = 147 nm and 200 nm with a peak at 172 nm and spectral lines in NIR. By the use of two monochromators, we measure the spectral resolved radiant flux from 120 nm to 1000 nm. The measurement uncertainty of 9.7 % is rather low for the VUV spectral range and depends mainly on the uncertainty of the used deuterium calibration standard from PTB (7%). Due to the strong temperature dependence of the transmission edge of silica used for the lamp vessel, the measurements are done in nitrogen atmosphere to ensure the convection cooling of the lamp. We measured the radiance distribution curve and radiant flux of Xe excimer lamps and could show the angle dependence of the spectrum. The measured correlation between the VUV band and the NIR lines gives us a better understanding of the plasma kinetics, which is used to optimize the pulsed excitation of the lamp.

  8. Radiant heat transfer network in the simulated protective clothing ; System under high heat flux

    NARCIS (Netherlands)

    Fukazawa, T.; Hartog, E.A. den; Daanen, H.A.M.; Penders-van Elk, N.; Tochihara, Y.; Havenith, G.

    2005-01-01

    A radiant network model was developed for design of the protective clothing system against solar and infrared radiative heat flux. A one-dimensional model was employed in the present study, because the aim of this study was to obtain precise temperature distribution through the system with use of a

  9. Calculation codes for radiant heat transfers; Les codes de calcul de rayonnement thermique

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    This document reports on 12 papers about computerized simulation and modeling of radiant heat transfers and fluid flows in various industrial and domestic situations: space heating, metal industry (furnaces, boilers..), aerospace industry (turbojet engines, combustion chambers) etc.. This workshop was organized by the ``radiation`` section of the French society of thermal engineers. (J.S.)

  10. Comparison and analysis on test methods of infrared radiant intensity of infrared decoy

    Science.gov (United States)

    Chen, Chunsheng; Dai, Mengyan; Liu, Haifeng; Fang, Guofeng; Xie, Changyou; Zhang, Tong

    2014-11-01

    The research on infrared radiant characteristics of typical target is important for the detection and recognition of target, infrared simulation calculation and design of electro-optical countermeasures. Thus it is essential to select appropriate test method and optimal calculation method to improve the test accuracy and reliability of infrared radiant intensity. In this paper, three instruments including SR5000 spectroradiometer (CI, MigdalHaEmek, Israel), remote sensing interferometer spectrometer Tensor37 (Bruker, Germany) and Image IR8325 (InfraTec Ltd, Germany) mid-infrared thermal imager were applied to test the infrared radiant (1μm-3μm - 3μm-5μm) intensity of decoy samples. Three methods were designed based on two operational principles including direct test and indirect test. The SR5000 spectroradiometer which is able to obtain the value of radian intensity immediately is regard as direct test. The other two instruments which deduce and calculate infrared radiant intensity according to Planck's law and Lambert's cosine law with some preliminary tested parameters such as the response voltage - the distribution of infrared radiant temperature of flaming samples and calibrated data by blackbody, however, are regard as indirect test. Reasons for the diversity of experiment results were provided through analysis on the concrete measurement theory and detailed calculation methods. Moreover, some rules and suggestions were put forward to improve the test accuracy and reliability of infrared radiant intensity when different methods were adopted. It is shown from experiment results that the average mid-infrared radiant intensity obtained from SR5000 was about 903W/Sr in near-infrared band - whereas Tensor 37 and Image IR8325 was about 834W/Sr and 547 W/Sr respectively. It was proved that maximum relative of calculated results from remote sensing interferometer spectrometer Tensor37 and results measured with SR5000 spectroradiometer is below 13%, which meet the

  11. Response functions of Fuji imaging plates to monoenergetic protons in the energy range 0.6-3.2 MeV.

    Science.gov (United States)

    Bonnet, T; Comet, M; Denis-Petit, D; Gobet, F; Hannachi, F; Tarisien, M; Versteegen, M; Aleonard, M M

    2013-01-01

    We have measured the responses of Fuji MS, SR, and TR imaging plates (IPs) to protons with energies ranging from 0.6 to 3.2 MeV. Monoenergetic protons were produced with the 3.5 MV AIFIRA (Applications Interdisciplinaires de Faisceaux d'Ions en Région Aquitaine) accelerator at the Centre d'Etudes Nucléaires de Bordeaux Gradignan (CENBG). The IPs were irradiated with protons backscattered off a tantalum target. We present the photo-stimulated luminescence response of the IPs together with the fading measurements for these IPs. A method is applied to allow correction of fading effects for variable proton irradiation duration. Using the IP fading corrections, a model of the IP response function to protons was developed. The model enables extrapolation of the IP response to protons up to proton energies of 10 MeV. Our work is finally compared to previous works conducted on Fuji TR IP response to protons.

  12. 辐射空调系统的低设计方法研究%Research on Low Exergy Design Method of Radiant Air Conditioning System

    Institute of Scientific and Technical Information of China (English)

    苏生; 寿青云; 何婧; 杨涌泉

    2012-01-01

    本文将建筑的能量供应链分为围护结构、室内空气、辐射末端、配水系统、蓄能系统、产能系统和空气处理系统等子系统,使用分析的热力学方法,根据各子系统自身的能量传输特性,分别进行了准稳态或动态的分析,推导得到各子系统的平衡方程式,并确定了输入、输出、消耗及储存的计算公式,建立起辐射空调系统的低设计方法。%The energy supply chain of buildings is divided into subsystems, including building envelope, room air, radiant system, distribution system, storage system, generation system and air handling system. Based on the exergy analysis method, the paper makes quasi-steady or dynamic analysis on energy transfer process of the subsystems. Exergy balance equations of each subsystem are derived, and the calculation formulas of exergy input, exergy output, exergy consumption and exergy storage are defined, then low exergy design method of radiant air conditioning system is gained.

  13. Create Your Plate

    Medline Plus

    Full Text Available ... A A A Listen En Español Create Your Plate Create Your Plate is a simple and effective ... and that your options are endless. Create Your Plate! Click on the plate sections below to add ...

  14. Analysis on explosive welded Al/Mg plates in as-received state and after heat treatment using the in situ high-energy X-ray diffraction

    Science.gov (United States)

    Zhou, Qiang; Chen, Pengwan; Nie, Zhihua; Lan, Yazhu

    2015-06-01

    The synchrotron-based HEXRD method has a much better angular resolution in the reciprocal space than neutron or traditional laboratory XRD, which creates an opportunity that could precisely study the crystal structure and parameter from the XRD pattern. Due to the high penetration depth of high-energy X-ray, the micro-strain and phase distribution could be determined precisely. In this work, the explosive welded 2024 Al/AZ31 Mg plates, both in as-received state and after heat treatment, were investigated by HEXRD method. The XRD patterns were taken shot-by-shot, going from Al to Mg with step width of 0.1mm. The micro-strain, phase distribution and grain size of each step were estimated and analyzed within the general mechanism of explosive welding. It is interesting to find that the intense texture observed in both cladded and base materials disappeared at the welded interface. Residual stress, which was obviously detected at the interface for the as-received sample, was eliminated after heat treatment. For the as-received sample, the strain of Mg along the path from interface to free surface was different for different Azimuth angle and different crystal orientation; but such variations didn't occur for Al.

  15. Underwater electrical discharge in plate to plate configuration

    Science.gov (United States)

    Stelmashuk, Vitaliy

    2016-09-01

    Two main configurations of high voltage electrodes submersed in water have been used for an electrical discharge generation: pin to pin and pin to plate. An electrical breakdown between plate electrodes is generally difficult to reproduce, because there is a uniform and weak electric field. One major advantage of using plate electrodes is their greater ``wear hardness'' to high-energy discharges. The plate electrodes can withstand extremely high energy deposition at which the pin electrode is quickly destroyed. The electrical discharge between plate electrodes can be initiated by creating an inhomogeneity in the electrical field. Two methods of discharge initiation between plate electrodes are proposed for this aim: 1) focusing of a shock wave in the interelectrode region; 2) a bubble injection into the electrode gap. The shock wave creates favourable conditions for the electrical breakdown between the two plate electrodes: it causes that numerous microbubbles of dissolved air start to grow and serve as locations for streamer initiation. In the second method the gas bubble is injected from the one of the electrodes, which has a gas inlet hole on the lateral face for this purpose. A ``volcano'' like morphology of positive streamers are observed in the experiments with weak electric field. The authors are grateful to MEYS grant INGO LG 15013.

  16. 空气源热泵地板供暖系统在北方寒冷地区应用的节能性与适用性%Energy efficiency and applicability of air-source heat pump floor radiant heating system in the Northern cold areas

    Institute of Scientific and Technical Information of China (English)

    李元哲; 于涛; 陈天侠

    2012-01-01

    从理论计算与工程实践两方面探讨了3种辐射供暖地板的表面温度、热阻及水温,分析表明在北方寒冷地区节能建筑中应用低温热水是可行的,并且节能效果明显.%Discusses the surface temperature, thermal resistance and water temperature of three kinds of radiation heating floors by theoretic calculation and project practice. The analysis shows that the application of low temperature water in energy efficient buildings in the area is practicable and the energy saving effects are obvious.

  17. 方孔蜂窝夹层板在爆炸载荷下的吸能特性%Energy absorption characteristics of a square hole honeycomb sandwich plate under blast loading

    Institute of Scientific and Technical Information of China (English)

    邓磊; 王安稳; 毛柳伟; 李魁彬

    2012-01-01

    The deformation mechanism and energy absorption characteristics of a square hole honeycomb sandwich plate under blast loading were analyzed with finite element numerical simulation method. With the given per unit area mass, cell size and core height, by comparing sandwich plate's energy absorptivity and face sheets's maximum deflection under different core relative densities, the optimal core relative density of the sandwich plate was obtained. It was shown that with this relative density, the core has the highest energy absorptivity, the minimum deflection in the bottom face sheet and the sandwich plate has superior shock resistance. Furthermore, the effects of geometrical parameters including cell size, core web thickness, core height and face sheet thickness on the energy absorptivity were discussed to obtain the optimal sandwich plate structure.%通过有限元数值模拟方法,对方孔蜂窝夹层板在爆炸冲击载荷下的变形机理和吸能特性进行了分析.在单位面积质量以及夹层板芯层薄壁间距、高度给定的情况下,通过对不同夹芯层相对密度下夹层板的吸能率以及上、下面板最大变形的比较,得出了最优的夹芯层相对密度.在此相对密度下,夹芯层吸能率最高,下面板变形最小,夹层板的抗冲击性能最优.同时还讨论了夹层板芯层薄壁间距、厚度、高度以及面板厚度对其各部分吸能率的影响,以得到最优化的夹层板结构.

  18. Operational Parameters of Hybrid Radiant Cooling Floor and Displacement Ventilation Air Conditioning System%地板辐射与置换通风空调系统运行参数

    Institute of Scientific and Technical Information of China (English)

    宣永梅; 王海亮; 黄翔

    2012-01-01

    The simulation model of hybrid radiant cooling floor and displacement ventilation air conditioning system was built and analyzed by software EnergyPlus. By comparing the simulation results and experimental data, it is shown that the simulated indoor air temperature and cooling capacity provided by radiant floor was +7% deviated from the experimental data. Based on the model, with the change of supply air parameters or supply water parameters, the cooling capacity provided by radiant floor and displacement ventilation, surface temperature of radiant floor, indoor air average temperature, AUST temperature were obtained. Combined with the indoor thermal comfort model, when indoor thermal comfort index PMV varied between ?.5 and 0. 5, the recommended supply air and supply water parameters were obtained to provide reference for engineering design and application.%建立了基于EnergyPlus的地板辐射供冷加置换通风空调系统模型,模拟得到的室内温度和辐射地板所承担冷量与实验结果的误差小于±7%.在此模型基础上,改变送风参数和供水参数,得到置换通风供冷量、辐射地板供冷量、地板表面温度、室内空气平均温度、AUST温度等参数的变化规律.结合热舒适性模型,得到满足室内热舒适性(-0.5≤PMV≤0.5)条件下,置换通风的送风参数和辐射地板的供水参数范围,为复合系统设计和应用提供依据.

  19. Impurity Conductivity in Semiconductors Resulting from Radiant Excitation

    OpenAIRE

    TOULANOV, Vakhab T.; DAVLETOVA, Aziza SH.

    2001-01-01

    This paper deals with the derivation of common formulae for induced impurity photosensibility with an arbitrary set of energy levels in the semiconductor gap. We give the expression for the real recombinational situation with two types of impurity levels as well. The basic properties and certain common peculiarities concerning induced photoconductivity in semiconductors are under consideration.

  20. Experimental evaluation of heat transfer coefficients between radiant ceiling and room

    DEFF Research Database (Denmark)

    Causone, Francesco; Corgnati, Stefano P.; Filippi, Marco

    2009-01-01

    The heat transfer coefficients between radiant surfaces and room are influenced by several parameters: surfaces temperature distributions, internal gains, air movements. The aim of this paper is to evaluate the heat transfer coefficients between radiant ceiling and room in typical conditions...... of occupancy of an office or residential building. Internal gains were therefore simulated using heated cylinders and heat losses using cooled surfaces. Evaluations were developed by means of experimental tests in an environmental chamber. Heat transfer coefficient may be expressed separately for radiation...... and convection or as one total parameter, but this choice may lead to different considerations about thermal performance of the system. In order to perform correct evaluations, it is therefore extremely important to use the proper reference temperature. The obtained values confirm tendencies found...

  1. Experimental and numerical analysis of air and radiant cooling systems in offices

    DEFF Research Database (Denmark)

    Corgnati, S. P.; Perino, M.; Fracastoro, G. V.;

    2009-01-01

    then extended to the coupled mixing ventilation and cold radiant ceiling panels. In particular, attention was drawn on the evaluation of the main supply jet properties (throw and penetration length) and on the draft risk caused by the cold air drop into the occupied zone. The study shows that such a problem can......This paper analyses office cooling systems based on all air mixing ventilation systems alone or coupled with radiant ceiling panels. This last solution may be effectively applied to retrofit all air systems that are no longer able to maintain a suitable thermal comfort in the indoor environment......, for example in offices with high thermal loads. This study was performed by means of CFD simulations previously validated through an experimental campaign performed in a full scale test room, simulating a typical two-desk office equipped with an all air mixing ventilation system. The numerical studies were...

  2. AN INVESTIGATION ON PHOTODIODE SWITCHING TIMES FOR PULSED HIGH RADIANT POWERS

    Directory of Open Access Journals (Sweden)

    Erdem ÖZÜTÜRK

    2004-02-01

    Full Text Available In many applications the light impinging on photodiode surface is pulsed. The change in parameter values in the equivalent circuit of photodiode is important if the amplitude of light pulses are large. In this situation, the change of parameter values with the amplitude of light pulse is nonlinear. Because of this, the nonlinear model of photodiode has been used in this search. By the reasons of photoconductive operation mode is a fast operation, the photoconductive circuit has been examined. In this study, according to the nonlinear behavior of photodiode at pulsed high radiant powers the changes of switching times have been investigated by using SPICE program and the changing of switching times with increasing radiant power has been showed.

  3. Numerical evaluation of the thermal performances of roof-mounted radiant barriers

    CERN Document Server

    Miranville, Frédéric; Lucas, Franck; Johan, Seriacaroupin

    2014-01-01

    This paper deals with the thermal performances of roof-mounted radiant barriers. Using dynamic simulations of a mathematical model of a whole test cell including a radiant barrier installed between the roof top and the ceiling, the thermal performance of the roof is calculated. The mean method is more particularly used to assess the thermal resistance of the building component and lead to a value which is compared to the one obtained for a mass insulation product such as polyurethane foam. On a further stage, the thermal mathematical model is replaced by a thermo-aeraulic model which is used to evaluate the thermal resistance of the roof as a function of the airflow rate. The results shows a better performance of the roof in this new configuration, which is widely used in practice. Finally, the mathematical relation between the thermal resistance and the airflow rate is proposed.

  4. Thermal environment in a simulated double office room with convective and radiant cooling systems

    DEFF Research Database (Denmark)

    Mustakallio, Panu; Bolashikov, Zhecho Dimitrov; Rezgals, Lauris

    2017-01-01

    The thermal environment in a double office room obtained with chilled beam (CB), chilled beam with radiant panel (CBR), chilled ceiling with ceiling installed mixing ventilation (CCMV) and overhead mixing total volume ventilation (MTVV) under summer (cooling) condition was compared. Design (peak......) and usual (average) heat load from solar radiation, office equipment, lighting and occupants was simulated, respectively at 62 W/m2 and 38 W/m2 under four different workstation layouts. Air temperature, globe (operative) temperature, radiant asymmetry, air velocity and turbulent intensity were measured...... CCMV especially in the design heat load cases. With CBR, the thermal environment was found to be between CB and CCMV. MTVV generated high draught level under the tested design heat load cases. All cooling systems generated similar thermal environment in the usual heat load cases. It would...

  5. Radiant Floor Cooling Combined with Mixing Ventilation in a Residential Room

    DEFF Research Database (Denmark)

    Krajcik, Michal; Simone, Angela; Tomasi, Roberta

    and by thermal manikin equivalent temperatures. Contaminant removal effectiveness and air change efficiency were used to characterize the ventilation effectiveness. The vertical air temperature differences that occurred when floor cooling was combined with cold conditioned air supply were well within the limits...... for comfortable thermal environment recommended by the standards. The cooler supply air mixed well and the effect of the position of air terminal devices was small. When warm unconditioned outside air was supplied by mixing ventilation in combination with the radiant floor cooling, low floor temperature......Mixing air ventilation system is one of the main ventilation concepts applied in residential buildings. The effect of combining the mixing ventilation system with the radiant floor heating has been well established, whereas the validation of using the floor for cooling in summer is still...

  6. Subjective evaluation of different ventilation concepts combined with radiant heating and cooling

    DEFF Research Database (Denmark)

    Krajcik, Michal; Tomasi, Roberta; Simone, Angela

    2012-01-01

    with displacement ventilation. Vertical air temperature distribution was more uniform for floor heating than for warm air heating, but there was no significant difference in thermal perception between the two mixing ventilation systems. For the summer conditions the subjects voted warmer than predicted by the PMV...... supplying warm air space heating or by a combination of radiant floor heating and mixing ventilation system. Next two test setups simulated an office room with two occupants during summer, ventilated and cooled by a single displacement ventilation system or by a radiant floor cooling combined...... and about one third preferred more air movement. No significant difference in thermal perception between the two displacement ventilation systems was found....

  7. Full scale measurements and CFD investigations of a wall radiant cooling system integrated in thin concrete walls

    DEFF Research Database (Denmark)

    Mikeska, Tomás; Fan, Jianhua; Svendsen, Svend

    2017-01-01

    Densely occupied spaces such as classrooms can very often have problems with overheating. It can be difficult to cool such spaces by means of a ventilation system without creating draughts and causing discomfort for occupants. The use of a wall radiant cooling system is a suitable option for spaces...... with a high occupant density. Radiant systems can remove most sensible heat loads resulting in a relatively small requirement for supply air for ventilation....

  8. Discussion on the Network Method for Calculating Radiant Interchange Within an Enclosure

    Institute of Scientific and Technical Information of China (English)

    1994-01-01

    In this paper the Δ-Y transformation of a linear electric circuit is introduced to simplify the computation of net radiant heat exchange on a surface of an enclosure with three surfaces.The illustration of the transformation is given by solving six problems taken from the textbooks.Some discussion concerning the possibility of extending the transformation method to enclosures with more than three surfaces,and the condition for applying the network method are also presented.

  9. A radiant heating test facility for space shuttle orbiter thermal protection system certification

    Science.gov (United States)

    Sherborne, W. D.; Milhoan, J. D.

    1980-01-01

    A large scale radiant heating test facility was constructed so that thermal certification tests can be performed on the new generation of thermal protection systems developed for the space shuttle orbiter. This facility simulates surface thermal gradients, onorbit cold-soak temperatures down to 200 K, entry heating temperatures to 1710 K in an oxidizing environment, and the dynamic entry pressure environment. The capabilities of the facility and the development of new test equipment are presented.

  10. High performance flat plate solar collector

    Science.gov (United States)

    Lansing, F. L.; Reynolds, R.

    1976-01-01

    The potential use of porous construction is presented to achieve efficient heat removal from a power producing solid and is applied to solar air heaters. Analytical solutions are given for the temperature distribution within a gas-cooled porous flat plate having its surface exposed to the sun's energy. The extracted thermal energy is calculated for two different types of plate transparency. Results show the great improvement in performance obtained with porous flat plate collectors as compared with analogous nonporous types.

  11. Optimum Pulse Duration and Radiant Exposure for Vascular Laser Therapy of Dark port-wine Skin: A Theoretical Study

    Science.gov (United States)

    Tunnell, James W.; Wang, Lihong V.; Anvari, Bahman

    2003-03-01

    Laser therapy for cutaneous hypervascular malformations such as port-wine stain birthmarks is currently not feasible for dark-skinned individuals. We study the effects of pulse duration, radiant exposure, and cryogen spray cooling (CSC) on the thermal response of skin, using a Monte Carlo based optical-thermal model. Thermal injury to the epidermis decreases with increasing pulse duration during irradiation at a constant radiant exposure; however, maintaining vascular injury requires that the radiant exposure also increase. At short pulse durations, only a minimal increase in radiant exposure is necessary for a therapeutic effect to be achieved because thermal diffusion from the vessels is minimal. However, at longer pulse durations the radiant exposure must be greatly increased. There exists an optimum pulse duration at which minimal damage to the epidermis and significant injury within the targeted vasculature occur. For example, the model predicts optimum pulse durations of approximately 1.5, 6, and 20 ms for vessel diameters of 40, 80, and 120 μm, respectively. Optimization of laser pulse duration and radiant exposure in combination with CSC may offer a means to treat cutaneous lesions in dark-skinned individuals.

  12. Indoor Air Quality Assessment in a Radiantly Cooled Tropical Building: a Case Study

    Directory of Open Access Journals (Sweden)

    Qi Jie KWONG

    2015-10-01

    Full Text Available Background: Many studies have been conducted to assess the indoor air quality (IAQ of buildings throughout the world because it is closely related to comfort, safety and work productivity of occupants. However, there is still lack of available literature about IAQ in tropical buildings that apply radiant cooling systems in conditioning the indoor air.Methods: This paper reports the results obtained from an IAQ audit that was conducted in a new radiantly cooled building in Malaysia, by focusing on the IAQ and thermal comfort parameters.Results: It was identified that the measured concentration levels for the five indoor air contaminants (CO, CO2, TVOC, formaldehyde and respirable particulates were within the threshold limit values (TLVs specified in the IAQ guidelines. Besides, no significant difference was found between the contaminant levels in each floor of the studied building, and a majority of the respondents did not encounter any form of physical discomfort. There is a risk of condensation problem, judging from the measured RH level.Conclusion: An increase of airflow rate and more dehumidification work in the studied building can be made to improve IAQ and prevention of condensation problem. Nevertheless, these schemes should be implemented carefully to avoid occupants’ discomfort. Relocation of workstations was suggested, especially for the lower floors, which had higher occupancy levels. Keywords: Indoor air quality (IAQ, Radiant cooling systems, IAQ audit, Indoor air contaminants, Condensation 

  13. Microchannel plate streak camera

    Science.gov (United States)

    Wang, Ching L.

    1989-01-01

    An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras. The improved streak camera is far more sensitive to photons (UV to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1000 KeV x-rays.

  14. Standarized performance tests of collectors of solar thermal energy: A steel flat-plate collector with two transparent covers and a proprietary coating

    Science.gov (United States)

    1976-01-01

    Basic test results of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator are given. The collector was tested over ranges of inlet temperature and flux level.

  15. COOLING, HEATING AND POWER PERFORMANCE OF SILICON-BASED FILM PV RADIANT PANEL MODULES%电热冷联产硅基薄膜光伏辐射板组件的性能研究

    Institute of Scientific and Technical Information of China (English)

    尹宝泉; 王一平; 朱丽

    2013-01-01

    Photovoltaic/thermal (PV/T) collectors are difficult to compromise between low temperature of PV cells and application of the co-generated heat.The cooling,heating and power cogeneration of module based on silicon thin-film solar module and radiant panel was proposed to solve the problem.The radiant panel collects the cold source for cooling the PV module,solves the unevenness of PV cooling and thermal utilization,and improves the comprehensive efficiency,the realize cooling,heating and power cogeneration.Comparative analysis for the PV module,radiant panel module and PV/T module were carried out in Langfang city,China.The experiment results showed that the conversion efficiency of PV cells is improved by 3%-6%,the thermal efficiency of radiant panel is improved slightly and reaches 45%,and its cooling capacity reduces slightly and still possesses 30-50W/m2.It is very important in promoting renewable energy applications in buildings.%对联产组件的性能进行户外测试,并分别与常规硅基薄膜组件、常规辐射板组件的性能进行对比.实验结果表明,相比于同类型硅基薄膜组件,硅基薄膜光伏辐射板组件的光电转换效率可提高3% ~6%;相对于同规格辐射板组件,其集热效率略有提高,达到45%;而其制冷量有所降低,但仍可达到30~50W/m2.

  16. Blanchability and sensory quality of large runner peanuts blanched in a radiant wall oven using infrared radiation.

    Science.gov (United States)

    Kettler, Katrina; Adhikari, Koushik; Singh, Rakesh K

    2017-10-01

    The main factors behind the growing popularity of infrared radiation heating in food processing include its energy efficiency, food quality retention and process speed, as well as the simplicity of equipment. Infrared radiation was employed as an alternative heat treatment to the conventional hot air method used in peanut blanching. The present study aimed to investigate the application of infrared heating for blanching peanuts and determine their blanchability and sensory quality under various processing conditions. The total blanchabilities (expressed as a percentage of total blanched) of the infrared radiation trials (radiant wall oven) at 343 °C for 1.5 min, 316 °C for 1.5 min, 288 °C for 1.5 min and 343 °C for 1 min did not differ significantly compared to the hot air control trials (impingement oven) at 100 °C for 30 and 20 min. All infrared trials had significantly lower (P infrared samples demonstrated the possible initiation of oxidation for the conventionally blanched sample at 18 weeks of storage at 24 °C (room temperature), with no indication of oxidation in the infrared samples stored at the same temperature. Infrared radiation peanut blanching is a viable alternative to conventional hot air blanching because of the shorter process time and longer shelf-life, as evident from the sensory storage study. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  17. Engineering Application Comparison about Energy Saving in HVAC System Between the Rotary wheel Energy Exchange and the Plate Type Energy Exchange%转轮与板式热交换器在空调系统节能中的应用比较

    Institute of Scientific and Technical Information of China (English)

    王兴; 黄敏

    2011-01-01

    本文通过对空调系统新风节能中占主导地位的转轮与板式热交换器在结构、原理、热回收效率、成本及使用特点上的比较分析,说明了这两种热交换器应用当中的一般规律,对转轮与板式热交换器在空调系统中的应用提出了一些建议。%In this paper,the author makes the application comparison between the rotary wheel energy exchange and plate type energy exchange in configuration、working principle、energy recovery efficiency 、application cost and working specialty,and summarize the basic working rule of these two type energy recovery device.At last the author give some suggestion in the engineering application of the rotary wheel energy exchange and plate type energy exchange.

  18. How do the results of the RADIANT trials impact on the management of NET patients? A systematic review of published studies

    OpenAIRE

    Pusceddu, S.; de Braud, F; Lo Russo, G; Concas, L.; Femia, D.; Vernieri, C.; Indini, A.; Formisano, B.; Buzzoni, R.

    2016-01-01

    In the last five years, everolimus has demonstrated efficacy in the treatment of neuroendocrine tumors (NETs) of different origins; its efficacy and safety were explored in the RADIANT trials, the last of which (RADIANT-4) has been recently published (December 2015). Overall, evidence collected from the RADIANT studies holds promise to change clinical practice for the treatment of NETs. In this paper, we comment on the role of everolimus within the therapeutic algorithm for NETs treatment, ba...

  19. How do the results of the RADIANT trials impact on the management of NET patients? A systematic review of published studies.

    Science.gov (United States)

    Pusceddu, Sara; De Braud, Filippo; Lo Russo, Giuseppe; Concas, Laura; Femia, Daniela; Vernieri, Claudio; Indini, Alice; Formisano, Barbara; Buzzoni, Roberto

    2016-07-12

    In the last five years, everolimus has demonstrated efficacy in the treatment of neuroendocrine tumors (NETs) of different origins; its efficacy and safety were explored in the RADIANT trials, the last of which (RADIANT-4) has been recently published (December 2015). Overall, evidence collected from the RADIANT studies holds promise to change clinical practice for the treatment of NETs.In this paper, we comment on the role of everolimus within the therapeutic algorithm for NETs treatment, based on the systematic analysis of the RADIANT trials and our experience.

  20. Solar ultraviolet and the occupational radiant exposure of Queensland school teachers: A comparative study between teaching classifications and behavior patterns.

    Science.gov (United States)

    Downs, Nathan J; Harrison, Simone L; Chavez, Daniel R Garzon; Parisi, Alfio V

    2016-05-01

    Classroom teachers located in Queensland, Australia are exposed to high levels of ambient solar ultraviolet as part of the occupational requirement to provide supervision of children during lunch and break times. We investigated the relationship between periods of outdoor occupational radiant exposure and available ambient solar radiation across different teaching classifications and schools relative to the daily occupational solar ultraviolet radiation (HICNIRP) protection standard of 30J/m(2). Self-reported daily sun exposure habits (n=480) and personal radiant exposures were monitored using calibrated polysulphone dosimeters (n=474) in 57 teaching staff from 6 different schools located in tropical north and southern Queensland. Daily radiant exposure patterns among teaching groups were compared to the ambient UV-Index. Personal sun exposures were stratified among teaching classifications, school location, school ownership (government vs non-government), and type (primary vs secondary). Median daily radiant exposures were 15J/m(2) and 5J/m(2)HICNIRP for schools located in northern and southern Queensland respectively. Of the 474 analyzed dosimeter-days, 23.0% were found to exceed the solar radiation protection standard, with the highest prevalence found among physical education teachers (57.4% dosimeter-days), followed by teacher aides (22.6% dosimeter-days) and classroom teachers (18.1% dosimeter-days). In Queensland, peak outdoor exposure times of teaching staff correspond with periods of extreme UV-Index. The daily occupational HICNIRP radiant exposure standard was exceeded in all schools and in all teaching classifications.

  1. A new simplified model to calculate surface temperature and heat transfer of radiant floor heating and cooling systems

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Zhao, Jianing; Olesen, Bjarne W.

    2015-01-01

    In this paper, a new simplified model to calculate surface temperature and heat transfer of radiant floor heating and cooling system was proposed and established using the conduction shape factor. Measured data from references were used to validate the proposed model. The results showed that the ......In this paper, a new simplified model to calculate surface temperature and heat transfer of radiant floor heating and cooling system was proposed and established using the conduction shape factor. Measured data from references were used to validate the proposed model. The results showed...... that the maximum differences between the calculated surface temperature and heat transfer using the proposed model and the measured data were 0.8 ºC and 8.1 W/m2 for radiant floor heating system when average water temperature between 40 ºC and 60 ºC. For the corresponding values were 0.3 ºC and 2.0 W/m2...... for radiant floor cooling systems when average water temperature between 10 ºC and 20 ºC. Numerically simulated data in this study were also used to validate the proposed model. The results showed that the surface temperature and heat transfer of radiant floor calculated by the proposed model agreed very well...

  2. Comparison of radiant and convective cooling of office room: effect of workstation layout

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho Dimitrov; Melikov, Arsen Krikor; Rezgals, Lauris;

    2014-01-01

    The impact of heat source location (room layout) on the thermal environment generated in a double office room with four cooling ventilation systems - overhead ventilation, chilled ceiling with overhead ventilation, active chilled beam and active chilled beam with radiant panels was measured...... and compared. The room was furnished with two workstations, two laptops and two thermal manikins resembling occupants. Two heat load levels, design (65 W/m2) and usual (39 W/m2), were generated by adding heat from warm panels simulating solar radiation. Two set-ups were studied: occupants sitting...

  3. Numerical analysis of diffuse ceiling ventilation and its integration with a radiant ceiling system

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per Kvols; Chen, Qingyan;

    2017-01-01

    number of design parameters encountered in practice. This study aimed to develop a numerical model that can reliably predict the airflow and thermal performance of the integrated system during the design stage. The model was validated by experiments under different operating conditions. The validated...... model was further applied to evaluate the effects of different design parameters, including the U-value of the diffuse ceiling panel, plenum height, plenum depth, and inlet configuration. In the integrated system, diffuse ceiling separated the radiant ceiling from the rest of the room and consequently...

  4. Sensitivity analysis of the thermal performance of radiant and convective terminals for cooling buildings

    DEFF Research Database (Denmark)

    Le Dréau, J.; Heiselberg, P.

    2014-01-01

    on both radiation and convection. In order to characterise the advantages and drawbacks of the different terminals, steady-state simulations of a typical office room have been performed using four types of terminals (active chilled beam, radiant floor, wall and ceiling). A sensitivity analysis has been...... conducted to determine the parameters influencing their thermal performance the most. The air change rate, the outdoor temperature and the air temperature stratification have the largest effect on the cooling need (maintaining a constant operative temperature). For air change rates higher than 0.5 ACH...

  5. On the Misdiagnosis of Surface Temperature Feedbacks from Variations in Earth’s Radiant Energy Balance

    Directory of Open Access Journals (Sweden)

    Roy W. Spencer

    2011-07-01

    Full Text Available The sensitivity of the climate system to an imposed radiative imbalance remains the largest source of uncertainty in projections of future anthropogenic climate change. Here we present further evidence that this uncertainty from an observational perspective is largely due to the masking of the radiative feedback signal by internal radiative forcing, probably due to natural cloud variations. That these internal radiative forcings exist and likely corrupt feedback diagnosis is demonstrated with lag regression analysis of satellite and coupled climate model data, interpreted with a simple forcing-feedback model. While the satellite-based metrics for the period 2000–2010 depart substantially in the direction of lower climate sensitivity from those similarly computed from coupled climate models, we find that, with traditional methods, it is not possible to accurately quantify this discrepancy in terms of the feedbacks which determine climate sensitivity. It is concluded that atmospheric feedback diagnosis of the climate system remains an unsolved problem, due primarily to the inability to distinguish between radiative forcing and radiative feedback in satellite radiative budget observations.

  6. Clouds and the Earth's Radiant Energy System. Investigating the Climate System. Problem-Based Classroom Modules

    Science.gov (United States)

    Smith, Sallie M.; Owens, Howard B.

    2003-01-01

    With support from National Aeronautics and Space Administration's (NASA's) Goddard Space Flight Center, Institute for Global Environmental Strategies (IGES) has developed educational materials that incorporate information and data from the Tropical Rainfall Measuring Mission (TRMM), a joint satellite mission between the United States and Japan.…

  7. Wetting on a plate with three-dimensional random heterogeneity and roughness. Equilibrium state and contact angle observed macroscopically; Sanjigen random na seijo wo motsu kotaimenjo deno nure kyodo. Energy heiko joken to kyshitekina sesshokukaku no kankei ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Kato, K.; Azuma, T. [Osaka City Univ., Osaka (Japan)

    1999-11-25

    A theoretical study was conducted to investigate the wetting behavior of liquid meniscus on a vertical plate with three-dimensional random characteristics of heterogeneity and roughness. The thermodynamic stable condition was derived by considering the minimum of system free energy. The local stable condition leads to a result similar to that obtained for a plate with two-dimensional characteristics, i.e., the system has many meta-stable states. For the stable condition of the whole system, a relation was derived between macroscopically observed contact angle and the surface characteristics. The product of cosine of the contact angle and liquid surface tension is equal to the energy difference for the liquid to wet the plate by apparent unit area. If the liquid wets the solid surface reversibly, there is only one contact angle observed macroscopically. This fact suggests that the contact angle hysteresis is caused by the irreversible motion when the liquid advances or recedes on the solid surface. The well-known Cassie and Wenzel's contact angles are explained as those corresponding to thermodynamically stable condition when the liquid wets the solid reversibly. (author)

  8. Influence of the Metal Volume Fraction on the permanent dent depth and energy absorption of GLARE plates subjected to low velocity impact

    Science.gov (United States)

    Bikakis, GSE; Savaidis, A.; Zalimidis, P.; Tsitos, S.

    2016-11-01

    Fiber-metal laminates are hybrid composite materials, consisting of alternating metal layers bonded to fiber-reinforced prepreg layers. GLARE (GLAss REinforced) belongs to this new family of materials. GLARE is the most successful fiber-metal laminate up to now and is currently being used for the construction of primary aerospace structures, such as the fuselage of the Airbus A380 air plane. Impact properties are very important in aerospace structures, since impact damage is caused by various sources, such as maintenance damage from dropped tools, collision between service cars or cargo and the structure, bird strikes and hail. The principal objective of this article is to evaluate the influence of the Metal Volume Fraction (MVF) on the low velocity impact response of GLARE fiber-metal laminates. Previously published differential equations of motion are employed for this purpose. The low velocity impact behavior of various circular GLARE plates is predicted and characteristic values of impact variables, which represent the impact phenomenon, are evaluated versus the corresponding MVF of the examined GLARE material grades. The considered GLARE plates are subjected to low velocity impact under identical impact conditions. A strong effect of the MVF on the maximum impact load and a significant effect on the maximum plate deflection of GLARE plates has been found.

  9. Standardized performance tests of collectors of solar thermal energy-a flat-plate collector with a single-tube serpentine flow distribution

    Science.gov (United States)

    Johnson, S.

    1976-01-01

    This preliminary data report gives basic test results of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and coolant flow rates. Collector efficienty is correlated in terms of inlet temperature and flux level.

  10. Fontes não radiantes e sua aplicação ao problema da fonte inverso

    OpenAIRE

    Werner Martins Vieira

    1988-01-01

    Resumo: Desenvolvemos propriedades e caracterizações equivalentes de fontes não radiantes. Construímos exemplos de fontes não radiantes fisicamente razoáveis. Tratamos do problema da fonte inverso e mostramos que sua solução possui em geral uma componente não radiante. Tal solução não é única e isso se deve a que os dados disponíveis nesse tipo de problema não dão acesso a essa componente. Mostramos que informações adicionais "a priore" a cerca da fonte podem dar unicidade a solução, i....

  11. Newborns' temperature submitted to radiant heat and to the Top Maternal device at birth

    Directory of Open Access Journals (Sweden)

    Rosemeire Sartori de Albuquerque

    Full Text Available ABSTRACT Objective: to compare the axillar temperatures of newborns that are put immediately after birth in skin-to-skin contact under the Top Maternal device, as compared to those in a radiant heat crib. Methods: comparatives observational study of the case-control type about temperature of 60 babies born at the Obstetric Center and Normal Delivery Center of a public hospital of the municipality of Sao Paulo, being them: 29 receiving assistance in heated crib and 31 in skin-to skin contact, shielded by a cotton tissue placed on mother's thorax, called Top Maternal. Results: the temperature of the babies of the skin-to-skin contact group presented higher values in a larger share of the time measures verified, as compared to those that were placed in radiant heat crib, independently from the place of birth. Differences between the two groups were not statistically significant. Conclusion: the study contributes to generate new knowledge, supporting the idea of keeping babies with their mothers immediately after birth protected with the Maternal Top, without harming their wellbeing, as it keeps the axillar temperature in recommendable levels.

  12. Inspection of radiant heating floor applying non-destructive testing techniques: GPR and IRT

    Directory of Open Access Journals (Sweden)

    Susana Lagüela-López

    2015-01-01

    Full Text Available La inspección de suelos radiantes requiere el uso de técnicas no destructivas, tratando de minimizar el impacto de la inspección, así como el tiempo y el coste, además de maximizar la información adquirida de cara al mejor diagnóstico posible. Con este objetivo, la aplicación de termografía infrarroja (IRT y georradar (GPR se propone para la inspección de suelos radiantes con cobertura de diferentes materiales, para evaluar las capacidades y la información adquirible con cada técnica. Los resultados muestran que cada técnica proporciona diferentes tipos de información: estado de las tuberías (IRT, geometría y configuración (GPR; concluyendo que la inspección óptima está formada por la combinación de ambas técnicas.

  13. An experimental investigation devoted to determine heat transfer characteristics in a radiant ceiling heating system

    Science.gov (United States)

    Koca, Aliihsan; Acikgoz, Ozgen; Çebi, Alican; Çetin, Gürsel; Dalkilic, Ahmet Selim; Wongwises, Somchai

    2017-08-01

    Investigations on heated ceiling method can be considered as a new research area in comparison to the common wall heating-cooling and cooled ceiling methods. In this work, heat transfer characteristics of a heated radiant ceiling system was investigated experimentally. There were different configurations for a single room design in order to determine the convective and radiative heat transfer rates. Almost all details on the arrangement of the test chamber, hydraulic circuit and radiant panels, the measurement equipment and experimental method including uncertainty analysis were revealed in detail indicating specific international standards. Total heat transfer amount from the panels were calculated as the sum of radiation to the unheated surfaces, convection to the air, and conduction heat loss from the backside of the panels. Integral expression of the view factors was calculated by means of the numerical evaluations using Matlab code. By means of this experimental chamber, the radiative, convective and total heat-transfer coefficient values along with the heat flux values provided from the ceiling to the unheated surrounding surfaces have been calculated. Moreover, the details of 28 different experimental case study measurements from the experimental chamber including the convective, radiative and total heat flux, and heat output results are given in a Table for other researchers to validate their theoretical models and empirical correlations.

  14. Processless offset printing plates

    Directory of Open Access Journals (Sweden)

    Sanja Mahović Poljaček

    2015-06-01

    Full Text Available With the implementation of platesetters in the offset printing plate making process, imaging of the printing plate became more stable and ensured increase of the printing plate quality. But as the chemical processing of the printing plates still highly influences the plate making process and the graphic reproduction workflow, development of printing plates that do not require chemical processing for offset printing technique has been one of the top interests in graphic technology in the last few years. The main reason for that came from the user experience, where majority of the problems with plate making process could be connected with the chemical processing of the printing plate. Furthermore, increased environmental standards lead to reducing of the chemicals used in the industrial processes. Considering these facts, different types of offset printing plates have been introduced to the market today. This paper presents some of the processless printing plates.

  15. Dynamic behavior of radiant cooling system based on capillary tubes in walls made of high performance concrete

    DEFF Research Database (Denmark)

    Mikeska, Tomás; Svendsen, Svend

    2015-01-01

    using cooling water for the radiant cooling system with a temperature only about 4K lower than the temperature of the room air. The relatively high speed reaction of the designed system is a result of the slim construction of the sandwich wall elements made of high performance concrete. (C) 2015...... the small amount of fresh air required by standards to provide a healthy indoor environment.This paper reports on experimental analyses evaluating the dynamic behavior of a test room equipped with a radiant cooling system composed of plastic capillary tubes integrated into the inner layer of sandwich wall...

  16. Radiant method in geometric seismics of complexly constructed stratified media. Luchevoy metod v geometricheskoy seysmike slozhnopostroyennykh sloistykh sred

    Energy Technology Data Exchange (ETDEWEB)

    Gerasimenko, A.N.

    1982-01-01

    A systematic presentation of the theory of the radiant method for solving the tasks of geometric seismics within the framework of its local-radiant concepts is presented. All the necessary information referring both to the employed mathematical apparatus (tensor analysis, Rimanov-conform-Euclidean chronometry), and to the results of using it in the tasks of analyzing the time field, continuing the geometric characteristics of the wave fronts along the rays, restoration and reflection-refraction of them on the curvilinear surfaces of the interface of the complexly-constructed heterogeneous-stratified media.

  17. Antena impresa para comunicaciones por satélite en banda Ka: Esquema de array y elementos radiantes

    OpenAIRE

    Martínez Osete, Beatriz

    2015-01-01

    Este trabajo fin de grado versa sobre el diseño y simulación del elemento radiante de una antena impresa con polarización circular, operativa en la banda Ka de frecuencias (18 – 31 GHz) para un sistema de comunicaciones entre aviones y satélites. Su principal característica es que la antena está formada por placas de circuito impreso apiladas. En las placas superiores se sitúan los elementos radiantes, mientras que en las capas internas se diseñan las líneas de transmisión, que forman la alim...

  18. Study of heating performance of radiant ceiling heating system and its impact on workers thermal comfort level of workers in typical industrial work shops

    Directory of Open Access Journals (Sweden)

    M. Aliabadi

    2013-08-01

    .Conclusion: Due to large space of these industrial units, producing appropriate heating by convection mechanism is too difficult and expensive. The results confirmed that if radiant heating system applied based on scientific design principles they could be effective in promotion of thermal comfort due to heating surrounding surface by radiant and also reducing fuel consumption.

  19. Radiant heat transfers in turbojet engines. Two applications, three levels of modeling; Transferts radiatifs dans les foyers de turboreacteurs. Deux applications, trois niveaux de modelisation

    Energy Technology Data Exchange (ETDEWEB)

    Schultz, J.L.; Desaulty, M. [SNECMA, Centre de Villaroche, 77 - Moissy-Cramayel (France); Taine, J. [Ecole Centrale de Paris, Laboratoire EM2C. CNRS, 92 - Chatenay-Malabry (France)

    1996-12-31

    Several applications linked with the dimensioning of turbojet engines require the use of modeling of radiant heat transfers. Two different applications are presented in this study: the modeling of heat transfers in the main combustion chamber, and modeling of the infrared signature of the post-combustion chamber of a military engine. In the first application, two types of radiant heat transfer modeling are presented: a global modeling based on empirical considerations and used in rapid pre-dimensioning methods, and a modeling based on a grey gases concept and combined to a ray shooting type technique allowing the determination of local radiant heat flux values. In the second application, a specific modeling of the radiant heat flux is used in the framework of a ray shooting method. Each model represents a different level of successive approximations of the radiant heat transfer adapted to flow specificities and to the performance requested. (J.S.) 16 refs.

  20. Project and construction of energy degrading and scattering plates for electron beam radiotherapy for skin diseases; Projeto e construcao de placas espalhadoras e degradadoras de energia para uso em radioterapia com feixes de eletrons para doencas de pele

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca, Gabriel Paiva

    2010-07-01

    There are many radiosensitive epidermotropics diseases such as mycosis fungo-ids and the syndrome of Sezary, coetaneous neoplasics originated from type T lymphocytes. Several studies indicate the eradication of the disease when treated with linear accelerators emitting electron beams with energies between 4 to 10 MeV. However, this treatment technique presents innumerable technical challenges since the disease in general reaches all patient's body, becoming necessary not only a very large field size radiation beam, but also deliver superficial doses limited to the skin depth. To reach the uniformity in the dose distribution, many techniques had already been developed. Based on these previous studies and guided by the report no. 23 of the American Association of Physicists in Medi-cine (AAPM), the present study developed an energy scattering and degrading plates and made dosimetry (computational and experimental), supplying subsidies for a future installation of Total Skin Electron Therapy (TSET) at the Servico de Radioterapia do Hospital das Clinicas de Sao Paulo. As part of the plates design, first of all, the energy spectrum of the 6 MeV electron beam of the VARIAN 2100C accelerator was reconstructed through Monte Carlo simulations using the MCNP4C code and based on experimental data. Once the spectrum is built, several materials were analyzed for the plates design based on radial and axial dose distribution, production of rays-x and dose attenuation. The simulation results were validated by experimental measurements in order to obtain a large field of radiation with 200 cm x 80 cm that meets the specifications of the AAPM protocol. (author)

  1. The energy balance of the earth' surface : a practical approach

    NARCIS (Netherlands)

    Bruin, de H.A.R.

    1982-01-01

    This study is devoted to the energy balance of the earth's surface with a special emphasis on practical applications. A simple picture of the energy exchange processes that take place at the ground is the following. Per unit time and area an amount of radiant energy is supplied to the surface. This

  2. The energy balance of the earth's surface : a practical approach

    NARCIS (Netherlands)

    Bruin, de H.A.R.

    1982-01-01

    This study is devoted to the energy balance of the earth's surface with a special emphasis on practical applications. A simple picture of the energy exchange processes that take place at the ground is the following. Per unit time and area an amount of radiant energy is supplied to the surface. This

  3. Technical evaluation of a solar heating system having conventional hydronic solar collectors and a radiant panel slab. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Starr, R.J.

    1984-04-01

    A simple innovative solar heating design (Solar Option One) using conventional hydronic solar collectors and a radiant panel slab was constructed. An objective of hybrid solar design is to combine the relative advantages of active and passive design approaches while minimizing their respective disadvantages. A test house using the Solar Option One heating system was experimentally monitored to determine its energy based performance during the 1982-83 heating season. The test residence is located in Lyndonville, Vermont, an area which has a characteristically cold and cloudy climate. The two story residence has a floor area of about 1400 square feet and is constructed on a 720 square foot 5.5 inch thick floor slab. A 24 inch packed gravel bed is located beneath the slab and the slab-gravel bed is insulated by two inches of polystyrene insulation. The test building is of frame construction and uses insulation levels which have become commonplace throughout the country. The structure would not fall into the superinsulated category but was tightly constructed so as to have a low infiltration level. The building is sun-tempered in that windows were concentrated somewhat on the South side and all but avoided on the North. A solar greenhouse on the South side of the building was closed off from the structure permanently throughout the testing so as to better observe the solar heating invention without confounding variables. The monitoring equipment generated an internal gain of about 17,000 BTUs per day, roughly the equivalent of occupancy by two persons. A full description of the experimental testing program is given. System efficiency and performance are reported.

  4. Crystal structure analysis of a hexatungstate by a high-energy X-ray diffraction experiment using an imaging plate Weissenberg camera at the BL04B2 beamline of SPring-8

    Energy Technology Data Exchange (ETDEWEB)

    Ozeki, Tomoji; Honma, Noritaka [Department of Chemistry and Materials Science, Tokyo Institute of Technology, Tokyo (Japan); Kusaka, Katsuhiro [Core Research for Evolutional Science and Technology (CREST), Japan Science and Technology Corporation (JST), Tokyo (Japan)

    2001-08-01

    An imaging plate Weissenberg camera was installed in the BL04B2 beamline of SPring-8 aiming at automated crystal structure determinations of small molecules. Since this beamline is designed to provide X-rays with the energies higher than 37 keV ({lambda}<0.33 A), this camera is advantageous in crystal structure analyses of heavily X-ray absorbing materials. The title crystal structure analysis led to precise positional parameters and well-behaved displacement parameters not only for heavy atoms but also for light atoms. (author)

  5. Theories for Elastic Plates via Orthogonal Polynomials

    DEFF Research Database (Denmark)

    Krenk, Steen

    1981-01-01

    A complementary energy functional is used to derive an infinite system of two-dimensional differential equations and appropriate boundary conditions for stresses and displacements in homogeneous anisotropic elastic plates. Stress boundary conditions are imposed on the faces a priori...

  6. Resistive plate chambers for tomography and radiography

    National Research Council Canada - National Science Library

    C. Thomay; P. Baesso; D. Cussans; J. Davies; P. Glaysher; S. Quillin; S. Robertson; C. Steer; C. Vassallo; J. Velthuis

    2012-01-01

    Resistive Plate Chambers (RPCs) are widely used in high energy physics for both tracking and triggering purposes, due to their excellent time resolution, rate capability, and good spatial resolution...

  7. Smart Control of Air Climatization System in Function on the Values of Mean Local Radiant Temperature

    Directory of Open Access Journals (Sweden)

    Giuseppe Cannistraro

    2015-08-01

    Full Text Available The hygrothermal comfort indoor conditions are defined as: those environmental conditions in which an individual exposed, expresses a state of satisfaction. These conditions cannot always be achieved anywhere in an optimal way and economically; in some cases they can be obtained only in work environments specific areas. This could be explained because of air conditioning systems designing is generally performed both on the basis of the fundamental parameters’ average values, such as temperature, velocity and relative humidity (Ta, va e φa and derived parameters such as operating temperature and mean radiant one (Top eTmr. However, in some specific cases - large open-spaces or in case of radiating surfaces - the descriptors defining indoor comfort conditions, based on average values, do not provide the optimum values required during the air conditioning systems design phase. This is largely due to the variability of real environmental parameters values compared to the average ones taken as input in the calculation. The results obtained in previous scientific papers on the thermal comfort have been the driving element of this work. It offers a simple, original and clever way of thinking about the new domotic systems for air conditioning, based on the “local mean radiant temperature.” This is a very important parameter when one wants to analyze comfort in environments characterized by the presence of radiating surfaces, as will be seen hereinafter. In order to take into account the effects of radiative exchanges in the open-space workplace, where any occupant may find themselves in different temperature and humidity conditions, this paper proposes an action on the domotic climate control, with ducts and vents air distribution placed in different zones. Comparisons were performed between the parameters values representing the punctual thermal comfort, with the Predicted Mean Vote PMV, in an environment marked by radiating surfaces (i

  8. 16 CFR Figure 4 to Subpart A of... - Flooring Radiant Panel Tester Schematic Low Flux End, Elevation

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Flooring Radiant Panel Tester Schematic Low Flux End, Elevation 4 Figure 4 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS INTERIM SAFETY STANDARD FOR CELLULOSE INSULATION The...

  9. From single photons to milliwatt radiant power-electron storage rings as radiation sources with a high dynamic range

    Energy Technology Data Exchange (ETDEWEB)

    Klein, R.; Thornagel, R.; Ulm, G. [Physikalisch-Technische Bundesanstalt, Berlin (Germany)

    2010-10-15

    The spectral radiant intensity of synchrotron radiation from electron storage rings can be calculated from basic electrodynamic relations (Schwinger equation) and it is directly proportional to the stored electron beam current, i.e. the number of stored electrons. With the necessary equipment installed to measure and control the electron beam current over a wide dynamic range, the radiant intensity of the synchrotron radiation can be adjusted accordingly without changing the spectrum. This is done, e.g., at the Metrology Light Source (MLS), the dedicated electron storage ring of the Physikalisch-Technische Bundesanstalt. The MLS is operated as a primary radiation source standard from the near IR up to the soft x-ray region and its operational parameters can be adjusted and accurately measured in a wide range: the electron beam current can be varied from 1 pA (one stored electron) up to 200 mA and thus the radiant intensity can be changed by more than 11 decades. The photon flux or radiant power for typical angular acceptances can thus be varied from single photons to milliwatts. This is a very powerful tool, e.g., for the characterization of the linearity of the response of radiation detectors or for the calibration of photon counting detectors. In this article we present an overview of past, current and possible future activities exploiting this feature. (authors)

  10. Operative temperature drifts and occupant satisfaction with thermal environment in three office buildings using radiant heating/ cooling system

    DEFF Research Database (Denmark)

    Kolarik, Jakub; Toftum, Jørn; Olesen, Bjarne W.

    2015-01-01

    The objective of this study was to analyse operative temperature drifts and occupant satisfaction with thermal environment in office buildings utilizing embedded radiant heating/cooling systems. Three office buildings were investigated: Town Hall in Viborg, Denmark (floor area 19400 m2), IDOM...

  11. Study on a mean radiant temperature measure tool based on an almost spherical array of radiometric sensors.

    Science.gov (United States)

    Fontana, L

    2012-11-01

    Mean radiant temperature has significant influence on indoor thermal comfort conditions. It has gained greater importance with the wider application of heating and cooling systems based on the use of large surfaces with a temperature slightly higher or lower than the indoor temperature (hot/cold floors or ceilings), because these systems operate through the radiant temperature control. The most used tool to measure radiant temperature, the globe thermometer, still has large margins of error, most of all due to the uncertainty in the evaluation of the convection heat exchanges between the globe surface and the indoor air. The feasibility of a device to measure mean radiant temperature in indoor condition, alternative to the globe-thermometer (obtained placing radiometric sensors (thermopiles) on the sides of different geometric regular solids), is proposed. The behavior has been investigated for different regular solids, such as the residual error and its dependence on walls average temperature, non-uniformity magnitude, orientation and position of the solid in the enclosure, room shape, non-uniformity temperature distribution. Icosahedron shape shows an excellent behavior, with errors lower than 0.1 K in all the examined conditions.

  12. Energy efficient design of heating system with plate heat exchangers%板式换热器供热系统的节能设计

    Institute of Scientific and Technical Information of China (English)

    张海宁

    2012-01-01

    By analyzing the operation parameter deviation from the design values, presents the key points of optimization design for plate heat exchangers. Represents the selection of circulating pumps and determination of the system pressure drop.%通过分析供热系统设计工况与运行工况出现偏差的原因,相应提出了换热器优化设计的要点.同时给出了循环水泵的设计选型和系统压降的确定方法.

  13. Electricity from photovoltaic solar cells. Flat-Plate Solar Array Project of the US Department of Energy's National Photovoltaics Program: 10 years of progress

    Science.gov (United States)

    Christensen, Elmer

    1985-01-01

    The objectives were to develop the flat-plate photovoltaic (PV) array technologies required for large-scale terrestrial use late in the 1980s and in the 1990s; advance crystalline silicon PV technologies; develop the technologies required to convert thin-film PV research results into viable module and array technology; and to stimulate transfer of knowledge of advanced PV materials, solar cells, modules, and arrays to the PV community. Progress reached on attaining these goals, along with future recommendations are discussed.

  14. Super-Radiant Dynamics, Doorways, and Resonances in Nuclei and Other Open Mesoscopic Systems

    CERN Document Server

    Auerbach, Naftali

    2011-01-01

    The phenomenon of super-radiance (Dicke effect, coherent spontaneous radiation by a gas of atoms coupled through the common radiation field) is well known in quantum optics. The review discusses similar physics that emerges in open and marginally stable quantum many-body systems. In the presence of open decay channels, the intrinsic states are coupled through the continuum. At sufficiently strong continuum coupling, the spectrum of resonances undergoes the restructuring with segregation of very broad super-radiant states and trapping of remaining long-lived compound states. The appropriate formalism describing this phenomenon is based on the Feshbach projection method and effective non-Hermitian Hamiltonian. A broader generalization is related to the idea of doorway states connecting quantum states of different structure. The method is explained in detail and the examples of applications are given to nuclear, atomic and particle physics. The interrelation of the collective dynamics through continuum and possi...

  15. Large modular graphite radiant heaters for testing space shuttle thermal protection systems

    Science.gov (United States)

    Cox, B. G.; Christensen, H. E.

    1975-01-01

    A graphite radiant heating array, capable of heating a 5-ft span of shuttle wing leading edge or a 4 x 8 ft flat panel through an entry thermal profile up to 3200 G, has been designed and built by McDonnell Douglas Corporation for NASA-Johnson Space Center. The unique, interchangeable, self-contained heather modules and their versatile support structure/coolant manifold are discussed along with the extensive thermal analysis that accompanied the design effort. A complete description of the geometric capabilities of the array, as well as the design details of the individual modules, is presented. The complete performance envelope of the array is discussed, including maximum temperature and gradients, heating uniformity, and the required utilities and support equipment.

  16. Human response to local convective and radiant cooling in a warm environment

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Krejcirikova, Barbora; Kaczmarczyk, Jan

    2013-01-01

    thermal comfort compared to the condition without cooling. The acceptability of the thermal environment was similar for all cooling devices. The acceptability of air movement and perceived air quality increased when local cooling methods were used. The best results were...... quality. The intensity of the reported sick building syndrome symptoms increased during the exposure time, with or without cooling devices in operation. Air movement had very little effect on sick building syndrome symptoms, but they increased when the pollution level was high. The lowest prevalence...... of symptoms was reported with personalized ventilation and with the radiant panel with attached fans, which also caused subjects to report less fatigue. Sick building syndrome symptoms increased most when the tabletop fan, generating movement of polluted room air, was in operation. The temperature...

  17. Perceived air quality, thermal comfort, and SBS symptoms at low air temperature and increased radiant temperature

    DEFF Research Database (Denmark)

    Toftum, Jørn; Reimann, Gregers Peter; Foldbjerg, P.

    2002-01-01

    This study investigated if low air temperature, which is known to improve the perception of air quality, also can reduce the intensity of some SBS symptoms. In a low-polluting office, human subjects were exposed to air at two temperatures 23 deg.C and 18 deg.C both with and without a pollution...... source present at the low temperature. To maintain overall thermal neutrality, the low air temperature was partly compensated for by individually controlled radiant heating, and partly by allowing subjects to modify clothing insulation. A reduction of the air temperature from 23 deg.C to 18 deg.......C suggested an improvement of the perceived air quality, while no systematic effect on symptom intensity was observed. The overall indoor environment was evaluated equally acceptable at both temperatures due to local thermal discomfort at the low air temperature....

  18. Effect of radiant heat on the surface hardness of glass polyalkenoate (ionomer) cement.

    Science.gov (United States)

    Woolford, M J

    1994-12-01

    The use of heat to improve mechanical properties of materials is a widely accepted phenomenon. It has been studied in dentistry with a view to improving the properties of resin composite. Dental cements may benefit by the application of heat, in particular with regard to their early surface properties. This study was carried out to examine the effect of the application of radiant heat to the surface hardness of one type of glass polyalkenoate cement. It was found that raising the temperature of the surface of the cement to a maximum of 60 degrees C significantly improved the early surface hardness of the material. The application of a high level of heat also improved the surface hardness of the cement after 24 h compared to cement which had not been heat treated. The use of heat would appear to accelerate the matrix-forming reaction of the material and although further work is necessary this technique may have clinical application.

  19. Large modular graphite radiant heaters for testing space shuttle thermal protection systems

    Science.gov (United States)

    Cox, B. G.; Christensen, H. E.

    1975-01-01

    A graphite radiant heating array, capable of heating a 5-ft span of shuttle wing leading edge or a 4 x 8 ft flat panel through an entry thermal profile up to 3200 G, has been designed and built by McDonnell Douglas Corporation for NASA-Johnson Space Center. The unique, interchangeable, self-contained heather modules and their versatile support structure/coolant manifold are discussed along with the extensive thermal analysis that accompanied the design effort. A complete description of the geometric capabilities of the array, as well as the design details of the individual modules, is presented. The complete performance envelope of the array is discussed, including maximum temperature and gradients, heating uniformity, and the required utilities and support equipment.

  20. Numerical Analysis of Effects of Atmospheric Ice Nuclei Concentrations on Radiant Properties of Cold Clouds

    Institute of Scientific and Technical Information of China (English)

    LI Juan; MAO Jietai; HU Zhijin; YOU Laiguang; ZHANG Qiang

    2005-01-01

    Numerical simulations of 18 precipitation days from June to September in 1996 with the 3D convective cloud model of CAMS (Chinese Academy of Meteorological Sciences, Version 2000) were conducted. In these simulations, the concentration of IN (ice nuclei) was assumed to increase by 5 times. The results show that when IN concentrations increase, the amounts of precipitation decrease, cloud tops heighten and the areas of cloud tops increase in 80 percent simulated clouds. Moreover, in 95 percent simulated clouds, the sizes of ice crystals in clouds decrease and quantities increase. These results mean that the physical properties of clouds will change when IN concentration increases. The radiant properties of clouds and climate may also change directly and indirectly.

  1. Análise da transferência de calor em coberturas com barreiras radiantes

    OpenAIRE

    Michels, Caren

    2007-01-01

    Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Civil. Nas cidades brasileiras o maior ganho térmico de edificações térreas ocorre pelo telhado. Assim, o emprego de barreiras radiantes tem a função de minimizar o fluxo de calor que atravessa o sistema de cobertura. Apesar da utilização deste tipo de isolante térmico ter crescido nos últimos anos, ainda não existem normas técnicas que tratem do assunto. Conseqüent...

  2. Radiant thinking and the use of the mind map in nurse practitioner education.

    Science.gov (United States)

    Spencer, Julie R; Anderson, Kelley M; Ellis, Kathryn K

    2013-05-01

    The concept of radiant thinking, which led to the concept of mind mapping, promotes all aspects of the brain working in synergy, with thought beginning from a central point. The mind map, which is a graphical technique to improve creative thinking and knowledge attainment, utilizes colors, images, codes, and dimensions to amplify and enhance key ideas. This technique augments the visualization of relationships and links between concepts, which aids in information acquisition, data retention, and overall comprehension. Faculty can promote students' use of the technique for brainstorming, organizing ideas, taking notes, learning collaboratively, presenting, and studying. These applications can be used in problem-based learning, developing plans of care, health promotion activities, synthesizing disease processes, and forming differential diagnoses. Mind mapping is a creative way for students to engage in a unique method of learning that can expand memory recall and help create a new environment for processing information.

  3. Mapping temperature and radiant geothermal heat flux anomalies in the Yellowstone geothermal system using ASTER thermal infrared data

    Science.gov (United States)

    Vaughan, R. Greg; Lowenstern, Jacob B.; Keszthelyi, Laszlo P.; Jaworowski, Cheryl; Heasler, Henry

    2012-01-01

    The purpose of this work was to use satellite-based thermal infrared (TIR) remote sensing data to measure, map, and monitor geothermal activity within the Yellowstone geothermal area to help meet the missions of both the U.S. Geological Survey Yellowstone Volcano Observatory and the Yellowstone National Park Geology Program. Specifically, the goals were to: 1) address the challenges of remotely characterizing the spatially and temporally dynamic thermal features in Yellowstone by using nighttime TIR data from the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) and 2) estimate the temperature, geothermal radiant emittance, and radiant geothermal heat flux (GHF) for Yellowstone’s thermal areas (both Park wide and for individual thermal areas). ASTER TIR data (90-m pixels) acquired at night during January and February, 2010, were used to estimate surface temperature, radiant emittance, and radiant GHF from all of Yellowstone’s thermal features, produce thermal anomaly maps, and update field-based maps of thermal areas. A background subtraction technique was used to isolate the geothermal component of TIR radiance from thermal radiance due to insolation. A lower limit for the Yellowstone’s total radiant GHF was established at ~2.0 GW, which is ~30-45% of the heat flux estimated through geochemical (Cl-flux) methods. Additionally, about 5 km2 was added to the geodatabase of mapped thermal areas. This work provides a framework for future satellite-based thermal monitoring at Yellowstone as well as exploration of other volcanic / geothermal systems on a global scale.

  4. Analysis on Thermal Resistance Test of Radiant Floor%辐射地板热阻实验分析

    Institute of Scientific and Technical Information of China (English)

    刘煜; 苏炳珲; 匡细细

    2015-01-01

    This paper provides the formula for calculating the theoretical thermal resistance of radiant floor based on the structure and thermal resistance of radiant floor, and sets up test beds to measure thermal resistance of radiant floor samples according to the standard, GB/TB13475-2008, Thermal insulation-Determination of steady-state thermal transmission Properties-Calibrated and guard hot box. And then some radiant floor samples have been tested by test beds. By comparing the results of experiment and theoretical calculation of thermal resistance and analyzing the fea-sibility of theoretical calculation and key factors of thermal resistance, this paper have provided data support for engi-neering calculation of thermal resistance of radiant floor, and engineering improving direction for extensive use of low temperature hot water.%本文根据辐射地板的结构和热阻理论给出了辐射地板热阻的理论计算公式,并根据《绝热稳态传热性质的测定-标定和防护热箱法》(GB/T 13475-2008)搭建了辐射地板样件的热阻测试实验台,对部分典型样件进行了实验。通过实验结果与理论热阻计算结果的对比,分析了理论计算的可行性,和影响热阻的关键因素。为辐射地板的工程计算提供理论支持,并为低温热水的广泛应用提供了工程改进的方向。

  5. Create Your Plate

    Medline Plus

    Full Text Available ... steps to get started: Using your dinner plate, put a line down the middle of the plate. ... vegetables . Now in one of the small sections, put grains and starchy foods. See this list of ...

  6. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate It's simple and effective for both managing diabetes and losing weight. Creating your plate lets ... 2016 Articles from Diabetes Forecast® magazine: wcie-meal-planning, In this section Food Planning Meals Diabetes Meal ...

  7. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal ... Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook ...

  8. Food guide plate

    Science.gov (United States)

    ... chips or cookies. VEGETABLES: MAKE HALF OF YOUR PLATE FRUITS AND VEGETABLES Vegetables can be raw, fresh, ... as a snack. FRUITS: MAKE HALF OF YOUR PLATE FRUITS AND VEGETABLES Fruits can be fresh, canned, ...

  9. Growth Plate Fractures

    Science.gov (United States)

    ... the most widely used by doctors is the Salter-Harris system, described below. Type I Fractures These ... incidence of growth plate fractures peaks in adolescence. Salter-Harris classification of growth plate fractures. AAOS does ...

  10. Create Your Plate

    Medline Plus

    Full Text Available ... Planning Meals Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook ... Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart- ...

  11. Create Your Plate

    Medline Plus

    Full Text Available ... Planning Meals Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook ... Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart- ...

  12. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate It's simple and effective for both managing diabetes and losing weight. Creating your plate lets you still choose the foods you want, but changes the portion sizes so you are getting larger ...

  13. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate It's simple and effective for both managing diabetes and losing weight. Creating your plate lets ... Sleeve Custom jerseys for your Tour de Cure team benefits the cause. Ask the Experts: Learn to ...

  14. Accelerated plate tectonics.

    Science.gov (United States)

    Anderson, D L

    1975-03-21

    The concept of a stressed elastic lithospheric plate riding on a viscous asthenosphere is used to calculate the recurrence interval of great earthquakes at convergent plate boundaries, the separation of decoupling and lithospheric earthquakes, and the migration pattern of large earthquakes along an arc. It is proposed that plate motions accelerate after great decoupling earthquakes and that most of the observed plate motions occur during short periods of time, separated by periods of relative quiescence.

  15. Newborns' temperature submitted to radiant heat and to the Top Maternal device at birth.

    Science.gov (United States)

    Albuquerque, Rosemeire Sartori de; Mariani, Corintio; Bersusa, Ana Aparecida Sanches; Dias, Vanessa Macedo; Silva, Maria Izabel Mota da

    2016-08-08

    to compare the axillar temperatures of newborns that are put immediately after birth in skin-to-skin contact under the Top Maternal device, as compared to those in a radiant heat crib. comparatives observational study of the case-control type about temperature of 60 babies born at the Obstetric Center and Normal Delivery Center of a public hospital of the municipality of Sao Paulo, being them: 29 receiving assistance in heated crib and 31 in skin-to skin contact, shielded by a cotton tissue placed on mother's thorax, called Top Maternal. the temperature of the babies of the skin-to-skin contact group presented higher values in a larger share of the time measures verified, as compared to those that were placed in radiant heat crib, independently from the place of birth. Differences between the two groups were not statistically significant. the study contributes to generate new knowledge, supporting the idea of keeping babies with their mothers immediately after birth protected with the Maternal Top, without harming their wellbeing, as it keeps the axillar temperature in recommendable levels. comparar a temperatura axilar dos recém-nascidos acomodados - imediatamente após o nascimento - em contato pele a pele, sob o Top Maternal, em berço de calor radiante. estudo comparativo observacional do tipo Caso-Controle sobre a temperatura de 60 bebês nascidos no Centro Obstétrico e Centro de Parto Normal de um hospital público do município de São Paulo, sendo: 29 assistidos em berço aquecido e 31 em contato pele a pele, protegidos por uma malha de algodão colocada sobre o tórax da mãe, denominada Top Maternal. a temperatura dos bebês do grupo de contato pele a pele teve maior valor na maioria dos tempos verificados comparada à dos que foram colocados em berço de calor radiante, independentemente do local de nascimento. A diferença entre os grupos não foi estatisticamente significante. o estudo contribui com a geração de um novo conhecimento que sustenta a

  16. Create Your Plate

    Medline Plus

    Full Text Available ... Reset Plate Share Create Your Plate ! Share: Seven Simple Steps to Create Your Plate It's simple and effective for both managing diabetes and losing ... en.html Have Type 2 Diabetes? Our free program will help you live well. More from diabetes. ...

  17. Obliquity along plate boundaries

    Science.gov (United States)

    Philippon, Mélody; Corti, Giacomo

    2016-12-01

    Most of the plate boundaries are activated obliquely with respect to the direction of far field stresses, as roughly only 8% of the plate boundaries total length shows a very low obliquity (ranging from 0 to 10°, sub-orthogonal to the plate displacement). The obliquity along plate boundaries is controlled by (i) lateral rheological variations within the lithosphere and (ii) consistency with the global plate circuit. Indeed, plate tectonics and magmatism drive rheological changes within the lithosphere and consequently influence strain localization. Geodynamical evolution controls large-scale mantle convection and plate formation, consumption, and re-organization, thus triggering plate kinematics variations, and the adjustment and re-orientation of far field stresses. These geological processes may thus result in plate boundaries that are not perpendicular but oblique to the direction of far field stresses. This paper reviews the global patterns of obliquity along plate boundaries. Using GPlate, we provide a statistical analysis of present-day obliquity along plate boundaries. Within this framework, by comparing natural examples and geological models, we discuss deformation patterns and kinematics recorded along oblique plate boundaries.

  18. Performance Evaluation of Radiator and Radiant Floor Heating Systems for an Office Room Connected to a Ground-Coupled Heat Pump

    Directory of Open Access Journals (Sweden)

    Ioan Sarbu

    2016-03-01

    Full Text Available A ground-coupled heat pump (GCHP system used to provide the space heating for an office room is a renewable, high performance technology. This paper discusses vapour compression-based HP systems, briefly describing the thermodynamic cycle calculations, as well as the coefficient of performance (COP and CO2 emissions of a HP with an electro-compressor and compares different heating systems in terms of energy consumption, thermal comfort and environmental impact. It is focused on an experimental study performed to test the energy efficiency of the radiator or radiant floor heating system for an office room connected to a GCHP. The main performance parameters (COP and CO2 emissions are obtained for one month of operation of the GCHP system, and a comparative analysis of these parameters is presented. Additionally, two numerical simulation models of useful thermal energy and the system COP in heating mode are developed using the Transient Systems Simulation (TRNSYS software. Finally, the simulations obtained from TRNSYS software are analysed and compared to the experimental data, showing good agreement and thus validating the simulation models.

  19. Angular shear plate

    Science.gov (United States)

    Ruda, Mitchell C [Tucson, AZ; Greynolds, Alan W [Tucson, AZ; Stuhlinger, Tilman W [Tucson, AZ

    2009-07-14

    One or more disc-shaped angular shear plates each include a region thereon having a thickness that varies with a nonlinear function. For the case of two such shear plates, they are positioned in a facing relationship and rotated relative to each other. Light passing through the variable thickness regions in the angular plates is refracted. By properly timing the relative rotation of the plates and by the use of an appropriate polynomial function for the thickness of the shear plate, light passing therethrough can be focused at variable positions.

  20. Standard Terminology Relating to Photovoltaic Solar Energy Conversion

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This terminology pertains to photovoltaic (radiant-to-electrical energy conversion) device performance measurements and is not a comprehensive list of terminology for photovoltaics in general. 1.2 Additional terms used in this terminology and of interest to solar energy may be found in Terminology E 772.

  1. Surface Emissivity of Building Enclosure of Gas-fired Radiant Heating System Impact on the Indoor Thermal Environment%燃气辐射采暖围护结构内表面发射率对空间热环境的影响研究

    Institute of Scientific and Technical Information of China (English)

    张大英; 邹闻; 杨忠国

    2011-01-01

    在对物理模型合理简化的基础上,对燃气辐射供暖空间温度场的分布进行了模拟,指出不同的围护结构内表面发射率对空间温度场及系统能耗的影响,得出降低围护结构内表面发射率可强化燃气辐射供暖技术。%In this paper, in a simplified physical model based on a reasonable, gas-fired radiant heating on the temperature distribution in space has been simulated, and the influences of different surface emissivity of building enclosure to indoor temperature and energy consumption are pointed. The result shows: reducing surface emissivity of building enclosure can enhance gas-fired radiant heating technology.

  2. The role of viscoelasticity in subducting plates

    Science.gov (United States)

    Farrington, R. J.; Moresi, L.-N.; Capitanio, F. A.

    2014-11-01

    of tectonic plates into Earth's mantle occurs when one plate bends beneath another at convergent plate boundaries. The characteristic time of deformation at these convergent boundaries approximates the Maxwell relaxation time for olivine at lithospheric temperatures and pressures, it is therefore by definition a viscoelastic process. While this is widely acknowledged, the large-scale features of subduction can, and have been, successfully reproduced assuming the plate deforms by a viscous mechanism alone. However, the energy rates and stress profile within convergent margins are influenced by viscoelastic deformation. In this study, viscoelastic stresses have been systematically introduced into numerical models of free subduction, using both the viscosity and shear modulus to control the Maxwell relaxation time. The introduction of an elastic deformation mechanism into subduction models produces deviations in both the stress profile and energy rates within the subduction hinge when compared to viscous only models. These variations result in an apparent viscosity that is variable throughout the length of the plate, decreasing upon approach and increasing upon leaving the hinge. At realistic Earth parameters, we show that viscoelastic stresses have a minor effect on morphology yet are less dissipative at depth and result in an energy transfer between the energy stored during bending and the energy released during unbending. We conclude that elasticity is important during both bending and unbending within the slab hinge with the resulting stress loading and energy profile indicating that slabs maintain larger deformation rates at smaller stresses during bending and retain their strength during unbending at depth.

  3. Surface and buildup region dose measurements with Markus parallel-plate ionization chamber, Gafchromic EBT3 film and MOSFET detector for high energy photon beams

    CERN Document Server

    Akbas, Ugur; Koksal, Canan; Bilge, Hatice

    2016-01-01

    The aim of the study was to investigate surface and buildup region doses for 6 MV photon beams using a Markus parallel-plate ionization chamber, GafChromic EBT3 film and MOSFET detector for different field sizes and beam angles. The measurements were made in a water equivalent solid phantom at the surface and in the buildup region of the 6 MV photon beams at 100 cm source-detector distance (SDD) for 5x5, 10x10 and 20x20 cm2 field sizes and 0, 30, 60, 80 and 90 beam angles. The surface doses for 10x10 cm2 field size were found to be 20.33%, 18.80% and 25.48% for Markus chamber, EBT3 film and MOSFET detector, respectively. The surface dose increased with field size for all dosimeters. As the angle of the incident radiation beam became more oblique, the surface dose increased. The effective measurement depths of dosimeters vary, thus the results of the measurements could be different. This issue can lead to mistakes at surface and buildup dosimetry, and must be taken into account.

  4. Effect of low temperature floor radiant heating in south Jiangxi area%赣南地区低温地板辐射采暖效果研究

    Institute of Scientific and Technical Information of China (English)

    石发恩; 付奇; 肖梅; 赵运超

    2016-01-01

    Although it is cold in winter and hot in summer, the south Jiangxi region is classified as non-heat-ing zone, where indoor thermal comfort is poor in winter. Due to various reasons, the demands for comfort liv-ing environment are growing, which leads to an urgent need to improve the indoor environment. Given the fea-tures of climate and geography in south Jiangxi area, the effect of low temperature floor radiant heating was re-searched and compared with that of heating of the air conditioning. Numerical simulations under two kinds of heating means for thermal environment in the heating room using CFD software were conducted to analyze air temperature field and humidity field. Indoor thermal environment was used by the PMV-PPD to evaluate index. The results show that compared with air conditioning, low temperature floor radiant heating is more comfort-able with indoor design temperature reducing 2~3 ℃, and energy saving of 15 %, which is beneficial to energy conservation and environmental protection.%赣南地区属于夏热冬冷地区,被列为非采暖区,冬季室内热舒适性较差。由于各方面的原因,人们对居住环境的要求越来越高,迫切需要改善室内热舒适性。结合赣南地区冬季气候及地域特点,研究低温地板辐射采暖的效果,并与空调采暖进行对比。利用CFD理论分别对该采暖室在2种采暖方式下的室内热环境进行数值模拟,分析室内空气温度场、湿度场,并用PMV-PPD 评价指标对室内热环境进行评定。研究表明,与空调采暖相比低温地板辐射采暖:室内热环境更加舒适;室内设计温度可降低2~3℃,能节约15%的能量,有利于节能环保。

  5. Experimental study including subjective evaluations of mixing and displacement ventilation combined with radiant floor heating/cooling system

    DEFF Research Database (Denmark)

    Krajcik, Michal; Tomasi, Roberta; Simone, Angela

    2013-01-01

    mixing ventilation systems was found. The next two tests simulated an office room during summer, ventilated and cooled either by a displacement ventilation system alone or by a displacement ventilation system combined with radiant floor cooling. Displacement ventilation combined with floor cooling had...... lower floor temperature, warmer supply air, and less homogeneous vertical temperature profile, but it did not result in thermal discomfort on feet/lower legs or discomfort due to a vertical air temperature difference higher than for a displacement ventilation system alone, where the floor temperature......Sixteen subjects evaluated the indoor environment in four experiments with different combinations of ventilation systems and radiant heating/cooling systems. In the first two tests, the simulated residential room was equipped either by a mixing ventilation system supplying warm air for space...

  6. Effusion plate using additive manufacturing methods

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Thomas Edward; Keener, Christopher Paul; Ostebee, Heath Michael; Wegerif, Daniel Gerritt

    2016-04-12

    Additive manufacturing techniques may be utilized to construct effusion plates. Such additive manufacturing techniques may include defining a configuration for an effusion plate having one or more internal cooling channels. The manufacturing techniques may further include depositing a powder into a chamber, applying an energy source to the deposited powder, and consolidating the powder into a cross-sectional shape corresponding to the defined configuration. Such methods may be implemented to construct an effusion plate having one or more channels with a curved cross-sectional geometry.

  7. Effusion plate using additive manufacturing methods

    Science.gov (United States)

    Johnson, Thomas Edward; Keener, Christopher Paul; Ostebee, Heath Michael; Wegerif, Daniel Gerritt

    2016-04-12

    Additive manufacturing techniques may be utilized to construct effusion plates. Such additive manufacturing techniques may include defining a configuration for an effusion plate having one or more internal cooling channels. The manufacturing techniques may further include depositing a powder into a chamber, applying an energy source to the deposited powder, and consolidating the powder into a cross-sectional shape corresponding to the defined configuration. Such methods may be implemented to construct an effusion plate having one or more channels with a curved cross-sectional geometry.

  8. Finite Temperature Casimir Effect for Corrugated Plates

    Institute of Scientific and Technical Information of China (English)

    ZHAO Yan; SHAO Cheng-Gang; LUO Jun

    2006-01-01

    @@ Using the path-integral method, the corrections to the Casimir energy due to the combined effect of surface roughness and the finite temperature are calculated. For the specific case of two sinusoidally corrugated plates,the lateral Casimir force at finite temperature is obtained. The amplitude of the lateral Casimir force has a maximum at an optimal wavelength of λ≈ 2H with the mean plate distance H. This optimal parameter relation is almost independent of temperature.

  9. Experimental research on the indoor temperature and humidity fields in radiant ceiling air-conditioning system under natural ventilation

    Science.gov (United States)

    Huang, Tao; Xiang, Yutong; Wang, Yonghong

    2017-05-01

    In this paper, the indoor temperature and humidity fields of the air in a metal ceiling radiant panel air conditioning system with fresh air under natural ventilation were researched. The temperature and humidity distributions at different height and different position were compared. Through the computation analysis of partial pressure of water vapor, the self-recovery characteristics of humidity after the natural ventilation was discussed.

  10. Generalized Fibonacci zone plates

    CERN Document Server

    Ke, Jie; Zhu, Jianqiang

    2015-01-01

    We propose a family of zone plates which are produced by the generalized Fibonacci sequences and their axial focusing properties are analyzed in detail. Compared with traditional Fresnel zone plates, the generalized Fibonacci zone plates present two axial foci with equal intensity. Besides, we propose an approach to adjust the axial locations of the two foci by means of different optical path difference, and further give the deterministic ratio of the two focal distances which attributes to their own generalized Fibonacci sequences. The generalized Fibonacci zone plates may allow for new applications in micro and nanophotonics.

  11. PAIR INFLUENCE OF WIND SPEED AND MEAN RADIANT TEMPERATURE ON OUTDOOR THERMAL COMFORT OF HUMID TROPICAL ENVIRONMENT

    Directory of Open Access Journals (Sweden)

    Sangkertadi Sangkertadi

    2016-01-01

    Full Text Available The purposes of this article is to explore knowledge of outdoor thermal comfort in humid tropical environment for urban activities especially for people in walking activity, and those who stationary/seated with moderate action. It will be characterized the pair influence of wind speed and radiant temperature on the outdoor thermal comfort. Many of researchers stated that those two microclimate variables give significant role on outdoor thermal comfort in tropical humid area. Outdoor Tropical Comfort (OTC model was used for simulation in this study. The model output is comfort scale that refers on ASHRAE definition. The model consists of two regression equations with variables of air temperature, globe temperature, wind speed, humidity and body posture, for two types of activity: walking and seated. From the results it can be stated that there is significant role of wind speed to reduce mean radiant temperature and globe temperature, when the velocity is elevated from 0.5 m/s to 2 m/s. However, the wind has not play significant role when the speed is changed from 2 m/s to 3.5 m/s. The results of the study may inspire us to implement effectiveness of electrical-fan equipment for outdoor space in order to get optimum wind speed, coupled with optimum design of shading devices to minimize radiant temperature for thermal comfort.

  12. The effect of rowing headgear on forced convective heat loss and radiant heat gain on a thermal manikin headform.

    Science.gov (United States)

    Bogerd, Cornelis P; Brühwiler, Paul A; Heus, Ronald

    2008-05-01

    Both radiant and forced convective heat flow were measured for a prototype rowing headgear and white and black cotton caps. The measurements were performed on a thermal manikin headform at a wind speed of 4.0 m . s(-1) (s = 0.1) in a climate chamber at 22.0 degrees C (s = 0.05), with and without radiant heat flow from a heat lamp, coming from either directly above (90 degrees ) or from above at an angle of 55 degrees . The effects of hair were studied by repeating selected measurements with a wig. All headgear reduced the radiant heat gain compared with the nude headform: about 80% for the caps and 95% for the prototype rowing headgear (P convective heat loss was reduced more by the caps (36%) than by the prototype rowing headgear (9%) (P heat gain contributed maximally 13% to the net heat transfer, with or without headgear, showing that forced convective heat loss is the dominant heat transfer parameter under the chosen conditions. The results of the headgear - wig combinations were qualitatively similar, with lower absolute heat transfer.

  13. Effects of radiant exposure and wavelength spectrum of light-curing units on chemical and physical properties of resin cements

    Directory of Open Access Journals (Sweden)

    Adriano Fonseca Lima

    2016-11-01

    Full Text Available Objectives In this study, we evaluated the influence of different radiant exposures provided by single-peak and polywave light-curing units (LCUs on the degree of conversion (DC and the mechanical properties of resin cements. Materials and Methods Six experimental groups were established for each cement (RelyX ARC, 3M ESPE; LuxaCore Dual, Ivoclar Vivadent; Variolink, DMG, according to the different radiant exposures (5, 10, and 20 J/cm2 and two LCUs (single-peak and polywave. The specimens were made (7 mm in length × 2 mm in width × 1 mm in height using silicone molds. After 24 hours of preparation, DC measurement was performed using Fourier transform infrared spectrometry. The same specimens were used for the evaluation of mechanical properties (flexural strength, FS; elastic modulus, E by a three-point bending test. Data were assessed for normality, after which two-way analysis of variance (ANOVA and post hoc Tukey's test were performed. Results No properties of the Variolink cement were influenced by any of the considered experimental conditions. In the case of the RelyX ARC cement, DC was higher when polywave LCU was used; FS and E were not influenced by the conditions evaluated. The LuxaCore cement showed greater sensitivity to the different protocols. Conclusions On the basis of these results, both the spectrum of light emitted and the radiant exposure used could affect the properties of resin cements. However, the influence was material-dependent.

  14. Surface and Buildup Region Dose Measurements with Markus Parallel-Plate Ionization Chamber, GafChromic EBT3 Film, and MOSFET Detector for High-Energy Photon Beams

    Directory of Open Access Journals (Sweden)

    Ugur Akbas

    2016-01-01

    Full Text Available The aim of the study was to investigate surface and buildup region doses for 6 MV and 15 MV photon beams using a Markus parallel-plate ionization chamber, GafChromic EBT3 film, and MOSFET detector for different field sizes and beam angles. The measurements were made in a water equivalent solid phantom at the surface and in the buildup region of the 6 MV and 15 MV photon beams at 100 cm source-detector distance for 5 × 5, 10 × 10, and 20 × 20 cm2 field sizes and 0°, 30°, 60°, and 80° beam angles. The surface doses using 6 MV photon beams for 10 × 10 cm2 field size were found to be 20.3%, 18.8%, and 25.5% for Markus chamber, EBT3 film, and MOSFET detector, respectively. The surface doses using 15 MV photon beams for 10 × 10 cm2 field size were found to be 14.9%, 13.4%, and 16.4% for Markus chamber, EBT3 film, and MOSFET detector, respectively. The surface dose increased with field size for all dosimeters. As the angle of the incident radiation beam became more oblique, the surface dose increased. The effective measurement depths of dosimeters vary; thus, the results of the measurements could be different. This issue can lead to mistakes at surface and buildup dosimetry and must be taken into account.

  15. Numerical and experimental analyses of the radiant heat flux produced by quartz heating systems

    Science.gov (United States)

    Turner, Travis L.; Ash, Robert L.

    1994-01-01

    A method is developed for predicting the radiant heat flux distribution produced by tungsten filament, tubular fused-quartz envelope heating systems with reflectors. The method is an application of Monte Carlo simulation, which takes the form of a random walk or ray tracing scheme. The method is applied to four systems of increasing complexity, including a single lamp without a reflector, a single lamp with a Hat reflector, a single lamp with a parabolic reflector, and up to six lamps in a six-lamp contoured-reflector heating unit. The application of the Monte Carlo method to the simulation of the thermal radiation generated by these systems is discussed. The procedures for numerical implementation are also presented. Experiments were conducted to study these quartz heating systems and to acquire measurements of the corresponding empirical heat flux distributions for correlation with analysis. The experiments were conducted such that several complicating factors could be isolated and studied sequentially. Comparisons of the experimental results with analysis are presented and discussed. Good agreement between the experimental and simulated results was obtained in all cases. This study shows that this method can be used to analyze very complicated quartz heating systems and can account for factors such as spectral properties, specular reflection from curved surfaces, source enhancement due to reflectors and/or adjacent sources, and interaction with a participating medium in a straightforward manner.

  16. Primary afferent depolarization and flexion reflexes produced by radiant heat stimulation of the skin.

    Science.gov (United States)

    Burke, R E; Rudomin, P; Vyklický, L; Zajac, F E

    1971-02-01

    1. The reflex effects of pulses of intense radiant heat applied to the skin of the central plantar pad have been studied in unanaesthetized (decerebrate) spinal cats.2. Pad heat pulses produced flexion of the ipsilateral hind limb and increased ipsilateral flexor monosynaptic reflexes, due to post-synaptic excitation of flexor alpha motoneurones. These effects were accompanied by reduction of extensor monosynaptic reflexes and post-synaptic inhibition of extensor motoneurones.3. Ipsilateral (and contralateral) pad heat pulses consistently evoked negative dorsal root potentials (DRPs) as well as increased excitability of both cutaneous and group Ib muscle afferent terminals. The excitability of group Ia afferents was sometimes also increased during pad heat pulses, but to a lesser extent.4. Pad heat pulses produced negative DRPs in preparations in which positive DRP components could be demonstrated following electrical stimulation of both skin and muscle nerves.5. The motor and primary afferent effects of heat pulses always accompanied one another, beginning after the pad surface temperature had reached rather high levels (usually 48-55 degrees C).6. Negative DRPs increased excitability of cutaneous and group Ib afferents, and motoneurone activation produced by pad heat pulses was essentially unmodified when conduction in large myelinated afferents from the central plantar pad was blocked by cooling the posterior tibial nerve trunk.7. It is concluded that adequate noxious activation of cutaneous afferents of small diameter produces primary afferent depolarization in a variety of large diameter afferent fibres, as well as post-synaptic effects in alpha motoneurones.

  17. Mathematical Modeling of Radiant Heat Transfer in Mirror Systems Considering Deep Reflecting Surface Defects

    Directory of Open Access Journals (Sweden)

    V. V. Leonov

    2014-01-01

    Full Text Available When designing large-sized mirror concentrating systems (MCS for high-temperature solar power plants, one must have at disposal reasonably reliable and economical methods and tools, making it possible to analyze its characteristics, to predict them depending on the operation conditions and accordingly to choose the most suitable system for the solution of particular task.Experimental determination of MCS characteristics requires complicated and expensive experimentation, having significant limitations on interpretation of the results, as well as limitations imposed due to the size of the structure. Therefore it is of particular interest to develop a mathematical model capable of estimating power characteristics of MCS considering the influence of operating conditions, design features, roughness and other surface defects.For efficient solution of the tasks the model must ensure simulation of solar radiant flux as well as simulation of geometrical and optical characteristics of reflection surface and their interaction. In this connection a statistical mathematical model of radiation heat exchange based on use of Monte Carlo methods and Finite Element Method was developed and realized in the software complex, making it possible to determine main characteristics of the MCS.In this paper the main attention is given to definition of MCS radiation characteristics with account for deep reflecting surface defects (cavities, craters. Deep cavities are not typical for MCS, but their occurrence is possible during operation as a result of erosion or any physical damage. For example, for space technology it is primarily micrometeorite erosion.

  18. Dependence of calculus retropulsion dynamics on fiber size and radiant exposure during Ho:YAG lithotripsy.

    Science.gov (United States)

    Lee, Ho; Ryan, Robert T; Kim, Jeehyun; Choi, Bernard; Arakeri, Navanit V; Teichman, Joel M H; Welch, A J

    2004-08-01

    During pulsed laser lithotripsy, the calculus is subject to a strong recoil momentum which moves the calculus away from laser delivery and prolongs the operation. This study was designed to quantify the recoil momentum during Ho:YAG laser lithotripsy. The correlation among crater shape, debris trajectory, laser-induced bubble and recoil momentum was investigated. Calculus phantoms made from plaster of Paris were ablated with free running Ho:YAG lasers. The dynamics of recoil action of a calculus phantom was monitored by a high-speed video camera and the laser ablation craters were examined with Optical Coherent Tomography (OCT). Higher radiant exposure resulted in larger ablation volume (mass) which increased the recoil momentum. Smaller fibers produced narrow craters with a steep contoured geometry and decreased recoil momentum compared to larger fibers. In the presence of water, recoil motion of the phantom deviated from that of phantom in air. Under certain conditions, we observed the phantom rocking towards the fiber after the laser pulse. The shape of the crater is one of the major contributing factors to the diminished recoil momentum of smaller fibers. The re-entrance flow of water induced by the bubble collapse is considered to be the cause of the rocking of the phantom.

  19. Performance analysis of porous radiant burners used in LPG cooking stove

    Directory of Open Access Journals (Sweden)

    P. Muthukumar, Piyush Anand, Prateek Sachdeva

    2011-03-01

    Full Text Available This paper discusses the performance investigations of a porous radiant burner (PRB used in LPG cooking stove. Performance of the burner was studied at different equivalence ratios and power intensities. Thermal efficiency was found using the water-boiling test described in IS: 4246:2002. The newly designed PRB showed a maximum thermal efficiency of about 71%, which is 6% higher than that of the conventional burners. Influence of ambient temperature on the thermal efficiency of the PRB was also investigated. Using a PRB of 80 mm diameter at the operating conditions of 0.68 equivalence ratio and 1.24 kW power intensity, the thermal efficiency was found to increase from 61% at 18.5 oC to 71% at 31 oC ambient temperature. The CO and NOx emissions of the PRB are in the range of 9 to 16 ppm and 0 to 0.2 ppm, respectively, while the respective values for the conventional burner are in the range of 50 to 225 ppm and 2 to 7 ppm.

  20. Realization of total spectral radiant flux scale at NMIJ with a goniophotometer/spectroradiometer

    Science.gov (United States)

    Godo, Kenji; Niwa, Kazuki; Kinoshita, Kenichi; Ichino, Yoshiro; Zama, Tatsuya

    2016-04-01

    In response to the strong demand for a total spectral radiant flux (TSRF) standard from domestic lighting manufacturers, such a scale has been realized in the visible range by means of a relative gonio-spectroradiometric method at the National Metrology Institute of Japan (NMIJ). Our gonio-spectroradiometric method employs spectral irradiance as well as a luminous intensity standard as reference standards. We have investigated several models of quartz-halogen lamps from domestic manufacturers with respect to their stability and decided a set of reference standard lamps for TSRF. Our carefully selected quartz-halogen lamps have sufficient stability as the standard lamp for TSRF after a 100 h seasoning process. The relative expanded uncertainty (k  =  2) for realization of the TSRF scale is between 3.1% (visible regions) and 4.1% (near ultraviolet region). We evaluated uncertainties related to the characteristics of the array spectroradiometer using experimental results and found some of those, such as effect of bandpass function, noticeably contributed to the total uncertainty.

  1. Hamiltonian system for orthotropic plate bending based on analogy theory

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Based on analogy between plane elasticity and plate bending as well as variational principles of mixed energy, Hamiltonian system is further led to orthotropic plate bending problems in this paper. Thus many effective methods of mathematical physics such as separation of variables and eigenfunction expansion can be employed in orthotropic plate bending problems as they are used in plane elasticity. Analytical solutions of rectangular plate are presented directly, which expands the range of analytical solutions. There is an essential distinction between this method and traditional semi-inverse method. Numerical results of orthotropic plate with two lateral sides fixed are included to demonstrate the effectiveness and accuracy of this method.

  2. Blue Willow Story Plates

    Science.gov (United States)

    Fontes, Kris

    2009-01-01

    In the December 1997 issue of "SchoolArts" is a lesson titled "Blue Willow Story Plates" by Susan Striker. In this article, the author shares how she used this lesson with her middle-school students many times over the years. Here, she describes a Blue Willow plate painting project that her students made.

  3. Create Your Plate

    Medline Plus

    Full Text Available ... In Memory In Honor Become a Member En Español Type 1 Type 2 About Us Online Community ... Page Text Size: A A A Listen En Español Create Your Plate Create Your Plate is a ...

  4. Create Your Plate

    Medline Plus

    Full Text Available ... Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal Planning ... Planning Meals Diabetes Meal Plans and a Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets ...

  5. Importance of 3-D radiant flux densities for outdoor human thermal comfort on clear-sky summer days in Freiburg, Southwest Germany

    Directory of Open Access Journals (Sweden)

    Hyunjung Lee

    2014-09-01

    Full Text Available This study concerns the role of short- and long-wave radiant flux densities from different directions in complex urban settings for human thermal comfort on clear-sky summer days. The aims of the investigation are to quantify the importance of the sky view factor as an urban design-dependent variable for the 3-D radiant flux densities absorbed by the standardized human-biometeorological reference person and to analyze the varying impact of the absorbed 3-D short- and long-wave radiant flux densities on the mean radiant temperature (Tmrt$T_{\\text{mrt}}$, near-surface air temperature (Ta$T_{\\text{a}}$ and physiologically equivalent temperature (PET.The results obtained by measuring campaigns and numerical simulations point to the different importance of the absorbed 3-D radiant flux densities for human thermal comfort characterized by Ta$T_{\\text{a}}$, Tmrt$T_{\\text{mrt}}$ and PET. The magnitude of Tmrt$T_{\\text{mrt}}$ is mainly determined by the total of the absorbed 3-D long-wave radiant flux densities. However, the fluctuations of Tmrt$T_{\\text{mrt}}$ are mainly governed by the total of the absorbed 3-D short-wave radiant flux densities. Their variance can be well explained by the variance of the sky view factor related to the southern part of the upper half space. Taking account of the different impact of the 3-D radiant flux densities, Tmrt$T_{\\text{mrt}}$ can be quite well estimated by a multiple regression using the total of the absorbed 3-D short-wave radiant flux densities and the absorbed long-wave radiant flux density from the lower half space as independent variables. PET can be well estimated by a multiple regression showing Tmrt$T_{\\text{mrt}}$ and Ta$T_{\\text{a}}$ as independent variables. On a hot summer day, the increase of the albedo of vertical building walls within a simple E-W oriented street canyon leads to a decrease of the surface temperature of the S-facing wall, but to an increase of Tmrt$T_{\\text{mrt}}$ and PET

  6. Energy

    CERN Document Server

    Foland, Andrew Dean

    2007-01-01

    Energy is the central concept of physics. Unable to be created or destroyed but transformable from one form to another, energy ultimately determines what is and isn''t possible in our universe. This book gives readers an appreciation for the limits of energy and the quantities of energy in the world around them. This fascinating book explores the major forms of energy: kinetic, potential, electrical, chemical, thermal, and nuclear.

  7. 基于滞回耗能谱的钢板剪力墙结构性态设计方法%Performance based seismic design of steel plate shear walls using hysteretic energy spectrum

    Institute of Scientific and Technical Information of China (English)

    孙国华; 顾强; 何若全; 方有珍

    2011-01-01

    The damages of buildings under earthquakes are related to cumulative effects of the ground motion.In order to reflect the ground motion effect,an energy-based seismic design method of steel plate shear wall,based on the normalized hysteretic energy spectrum and accumulated ductility spectrum,was proposed.The computation methods for accumulated hysteretic energy of steel beam,steel column,and steel plate infill wall were constructed.The different hysteretic behavior of steel components was taken into consideration by pinching parameters.Capacity design method was used to determine the sections of steel components,and to ensure that SPSW could produce the favorite failure mode under rare earthquakes.A ten-story,three-span SPSW was designed based on this new design method.The seismic behavior was evaluated by nonlinear time history method.The maximum average story drift of the example SPSW structure can meet the requirement of the Chinese seismic code.The reliability of this method is proved.%结构在地震作用下的损伤往往与地面运动的加速度循环特征密切相关,为反映这种地面运动特征,引入了累积延性比,并结合标准化的滞回耗能谱,提出了钢板剪力墙(SPSW)结构基于能量的性态抗震设计方法。该方法给出了SPSW结构中钢梁、钢柱、剪力墙板累积滞回耗能的计算方法,引入捏缩系数来反映构件的滞回特性,采用能力设计方法确定剪力墙板周边的梁、柱截面,确保SPSW结构在罕遇地震作用下出现理想的塑性机构。通过对1榀10层3跨的SPSW结构算例分析,采用弹塑性时程分析对所设计结构进行了验证。计算结果表明:结构最大楼层侧移平均值满足我国现行抗震规范的要求,与设计假定的目标侧移基本一致,验证了建议方法的合理性。

  8. Pixelated neutron image plates

    Science.gov (United States)

    Schlapp, M.; Conrad, H.; von Seggern, H.

    2004-09-01

    Neutron image plates (NIPs) have found widespread application as neutron detectors for single-crystal and powder diffraction, small-angle scattering and tomography. After neutron exposure, the image plate can be read out by scanning with a laser. Commercially available NIPs consist of a powder mixture of BaFBr : Eu2+ and Gd2O3 dispersed in a polymer matrix and supported by a flexible polymer sheet. Since BaFBr : Eu2+ is an excellent x-ray storage phosphor, these NIPs are particularly sensitive to ggr-radiation, which is always present as a background radiation in neutron experiments. In this work we present results on NIPs consisting of KCl : Eu2+ and LiF that were fabricated into ceramic image plates in which the alkali halides act as a self-supporting matrix without the necessity for using a polymeric binder. An advantage of this type of NIP is the significantly reduced ggr-sensitivity. However, the much lower neutron absorption cross section of LiF compared with Gd2O3 demands a thicker image plate for obtaining comparable neutron absorption. The greater thickness of the NIP inevitably leads to a loss in spatial resolution of the image plate. However, this reduction in resolution can be restricted by a novel image plate concept in which a ceramic structure with square cells (referred to as a 'honeycomb') is embedded in the NIP, resulting in a pixelated image plate. In such a NIP the read-out light is confined to the particular illuminated pixel, decoupling the spatial resolution from the optical properties of the image plate material and morphology. In this work, a comparison of experimentally determined and simulated spatial resolutions of pixelated and unstructured image plates for a fixed read-out laser intensity is presented, as well as simulations of the properties of these NIPs at higher laser powers.

  9. Plate removal following orthognathic surgery.

    Science.gov (United States)

    Little, Mhairi; Langford, Richard Julian; Bhanji, Adam; Farr, David

    2015-11-01

    The objectives of this study are to determine the removal rates of orthognathic plates used during orthognathic surgery at James Cook University Hospital and describe the reasons for plate removal. 202 consecutive orthognathic cases were identified between July 2004 and July 2012. Demographics and procedure details were collected for these patients. Patients from this group who returned to theatre for plate removal between July 2004 and November 2012 were identified and their notes were analysed for data including reason for plate removal, age, smoking status, sex and time to plate removal. 3.2% of plates were removed with proportionally more plates removed from the mandible than the maxilla. 10.4% of patients required removal of one or more plate. Most plates were removed within the first post-operative year. The commonest reasons for plate removal were plate exposure and infection. The plate removal rates in our study are comparable to those seen in the literature.

  10. Anisotropic elastic plates

    CERN Document Server

    Hwu, Chyanbin

    2010-01-01

    As structural elements, anisotropic elastic plates find wide applications in modern technology. The plates here are considered to be subjected to not only in plane load but also transverse load. In other words, both plane and plate bending problems as well as the stretching-bending coupling problems are all explained in this book. In addition to the introduction of the theory of anisotropic elasticity, several important subjects have are discussed in this book such as interfaces, cracks, holes, inclusions, contact problems, piezoelectric materials, thermoelastic problems and boundary element a

  11. Plating in Top Agar

    OpenAIRE

    sprotocols

    2014-01-01

    1. Warm plates to room temperature before use. Cold plates causes the top agar to solidify irregularly. DO not warm plates to 37° as the top agar will take forever to solidify. - Prepare top agar as the appropriate liquid medium with 0.7% agar. Keeping 100 mL bottles is convenient. For phages, use λ top agar, which is less rich and yields bigger plaques. - Melt top agar in the microwave completely. Allow the agar to boil after liquification; incompletely melted agar looks liquid, but is...

  12. Create Your Plate

    Medline Plus

    Full Text Available ... blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ... but changes the portion sizes so you are getting larger portions of non-starchy vegetables and a ...

  13. Create Your Plate

    Medline Plus

    Full Text Available ... blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ... 4/Box) Taking the guesswork out of portion control has never been easier. It can be a ...

  14. Tectonic Plate Movement.

    Science.gov (United States)

    Landalf, Helen

    1998-01-01

    Presents an activity that employs movement to enable students to understand concepts related to plate tectonics. Argues that movement brings topics to life in a concrete way and helps children retain knowledge. (DDR)

  15. MyPlate

    Science.gov (United States)

    ... our stage of life, situations, preferences, access to food, culture, traditions, and the personal decisions we make over time. All your food and beverage choices count. MyPlate offers ideas and ...

  16. Create Your Plate

    Medline Plus

    Full Text Available ... blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ... you have an easy portion control solution that works. Last Reviewed: October 8, 2015 Last Edited: September ...

  17. Designing Assemblies Of Plates

    Science.gov (United States)

    Williams, F. W.; Kennedy, D.; Butler, R.; Aston, G.; Anderson, M. S.

    1992-01-01

    VICONOPT calculates vibrations and instabilities of assemblies of prismatic plates. Designed for efficient, accurate analysis of buckling and vibration, and for optimum design of panels of composite materials. Written in FORTRAN 77.

  18. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal Planning What Can I Eat? Making Healthy Food Choices Diabetes Superfoods Non-starchy Vegetables Grains and Starchy Vegetables ...

  19. Create Your Plate

    Medline Plus

    Full Text Available ... Recipes Association Cookbook Recipes Planning Meals Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning ... serving of dairy or both as your meal plan allows. Choose healthy fats in small amounts. For ...

  20. Create Your Plate

    Medline Plus

    Full Text Available ... 1 Diabetes Get Started Safely Get And Stay Fit Types of Activity Weight Loss Assess Your Lifestyle ... manage portion control wherever you are. Now, our best-selling, sectioned to-go plate with easy-sealing ...

  1. Create Your Plate

    Medline Plus

    Full Text Available ... Plate is a simple and effective way to manage your blood glucose levels and lose weight. With ... been easier. It can be a challenge to manage portion control wherever you are. Now, our best- ...

  2. Tectonic Plate Movement.

    Science.gov (United States)

    Landalf, Helen

    1998-01-01

    Presents an activity that employs movement to enable students to understand concepts related to plate tectonics. Argues that movement brings topics to life in a concrete way and helps children retain knowledge. (DDR)

  3. Create Your Plate

    Medline Plus

    Full Text Available ... Carbohydrates Carbohydrate Counting Make Your Carbs Count Glycemic ... to manage portion control wherever you are. Now, our best-selling, sectioned to-go plate with easy-sealing ...

  4. Origami - Folded Plate Structures

    OpenAIRE

    Buri, Hans Ulrich

    2010-01-01

    This research investigates new methods of designing folded plate structures that can be built with cross-laminated timber panels. Folded plate structures are attractive to both architects and engineers for their structural, spatial, and plastic qualities. Thin surfaces can be stiffened by a series of folds, and thus not only cover space, but also act as load bearing elements. The variation of light and shadow along the folded faces emphasizes the plas...

  5. Fractal multifiber microchannel plates

    Science.gov (United States)

    Cook, Lee M.; Feller, W. B.; Kenter, Almus T.; Chappell, Jon H.

    1992-01-01

    The construction and performance of microchannel plates (MCPs) made using fractal tiling mehtods are reviewed. MCPs with 40 mm active areas having near-perfect channel ordering were produced. These plates demonstrated electrical performance characteristics equivalent to conventionally constructed MCPs. These apparently are the first MCPs which have a sufficiently high degree of order to permit single channel addressability. Potential applications for these devices and the prospects for further development are discussed.

  6. Energy

    CERN Document Server

    Robertson, William C

    2002-01-01

    Confounded by kinetic energy? Suspect that teaching about simple machines isn t really so simple? Exasperated by electricity? If you fear the study of energy is beyond you, this entertaining book will do more than introduce you to the topic. It will help you actually understand it. At the book s heart are easy-to-grasp explanations of energy basics work, kinetic energy, potential energy, and the transformation of energy and energy as it relates to simple machines, heat energy, temperature, and heat transfer. Irreverent author Bill Robertson suggests activities that bring the basic concepts of energy to life with common household objects. Each chapter ends with a summary and an applications section that uses practical examples such as roller coasters and home heating systems to explain energy transformations and convection cells. The final chapter brings together key concepts in an easy-to-grasp explanation of how electricity is generated. Energy is the second book in the Stop Faking It! series published by NS...

  7. Integrated thermal infrared imaging and Structure-from-Motion photogrametry to map apparent temperature and radiant hydrothermal heat flux at Mammoth Mountain, CA USA

    Science.gov (United States)

    Lewis, Aaron; George Hilley,; Lewicki, Jennifer L.

    2015-01-01

    This work presents a method to create high-resolution (cm-scale) orthorectified and georeferenced maps of apparent surface temperature and radiant hydrothermal heat flux and estimate the radiant hydrothermal heat emission rate from a study area. A ground-based thermal infrared (TIR) camera was used to collect (1) a set of overlapping and offset visible imagery around the study area during the daytime and (2) time series of co-located visible and TIR imagery at one or more sites within the study area from pre-dawn to daytime. Daytime visible imagery was processed using the Structure-from-Motion photogrammetric method to create a digital elevation model onto which pre-dawn TIR imagery was orthorectified and georeferenced. Three-dimensional maps of apparent surface temperature and radiant hydrothermal heat flux were then visualized and analyzed from various computer platforms (e.g., Google Earth, ArcGIS). We demonstrate this method at the Mammoth Mountain fumarole area on Mammoth Mountain, CA. Time-averaged apparent surface temperatures and radiant hydrothermal heat fluxes were observed up to 73.7 oC and 450 W m-2, respectively, while the estimated radiant hydrothermal heat emission rate from the area was 1.54 kW. Results should provide a basis for monitoring potential volcanic unrest and mitigating hydrothermal heat-related hazards on the volcano.

  8. Transient Heat Transfer in Radiant Floors: A Comparative Analysis between the Lumped Capacitance Method and Infrared Thermography Measurements

    Directory of Open Access Journals (Sweden)

    Giorgio Baldinelli

    2016-07-01

    Full Text Available The paper presents a simplified mathematical model to describe the transient heat transfer of a radiant floor heating system. A purpose-built test room has been realized to investigate the actual thermal response of a concrete radiant floor in unsteady-state conditions. Beyond the temperature sensors needed for the standard thermal analysis of the heat transfer inside the chamber, the floor temperature was retrieved by means of an infrared thermography camera, in order to validate more precisely the proposed analytical model. The infrared thermography analysis gives interesting information on the floor temperature distribution during the transient, highlighting the pipes’ layout and, if present, inhomogeneous floor zones. The thermal images have been elaborated in order to set and tune the colour map. A portion of the image has been defined for measuring the surface floor temperatures with a previous evaluation of the parameters dealing with the thermographic technique, in order to perform the quantitative survey. The comparison results show that the calculated air and floor temperatures substantially agree with the temperatures measured by infrared thermography and thermocouples, provided that the boundary conditions obtained by the field measurements are strictly reproduced in the lumped capacitance mathematical model. The difference between the two approaches results in values lower than 4 °C during the entire monitoring period: a satisfactory outcome, considering the approximations of the analytical method. The proposed model and its infrared thermography measurements validation represent a useful tool to understand at first sight the floor radiant panels behaviour in the start-up and switch off period, at the aim of gather useful information for the difficult task of their regulation.

  9. Solar radiation and cooling load calculation for radiant systems: Definition and evaluation of the Direct Solar Load

    DEFF Research Database (Denmark)

    Causone, Francesco; Corgnati, Stefano P.; Filippi, Marco

    2010-01-01

    The study of the influence of solar radiation on the built environment is a basic issue in building physics and currently it is extremely important because glazed envelopes are widely used in contemporary architecture. In the present study, the removal of solar heat gains by radiant cooling systems...... is investigated. Particular attention is given to the portion of solar radiation converted to cooling load, without taking part in thermal absorption phenomena due to the thermal mass of the room. This specific component of the cooling load is defined as the Direct Solar Load. A simplified procedure to correctly...

  10. Simulación numérica de hornos de combustión equipados con quemadores radiantes

    OpenAIRE

    Arrieta Burgos, Andrés; Universidad de Antioquia; Cadavid Sierra, Francisco; Universidad de Antioquia; Amell Arrieta, Andrés; Universidad de Antioquia

    2011-01-01

    Las simulaciones de hornos de combustión equipados con quemadores radiantes habitualmente se realizan asumiendo una combustión completamente desarrollada en las copas de los quemadores. Este supuesto minimiza el costo computacional ocasionado al simular cientos de quemadores, sin embargo, implica simular un horno donde no se modela el desarrollo de las reacciones de combustión y no se considera la interacción de la geometría de los quemadores en los perfiles de flujo y temperatura al interior...

  11. Radiant Ceiling Panels Combined with Localized Methods for Improved Thermal Comfort of Both Patient and Medical Staff in Patient Room

    DEFF Research Database (Denmark)

    Mori, Sakura; Barova, Mariya; Bolashikov, Zhecho Dimitrov;

    2012-01-01

    The objectives were to identify whether ceiling installed radiant heating panels can provide thermal comfort to the occupants in a patient room, and to determine a method for optimal thermal environment to both patient and medical staff simultaneously. The experiments were performed in a climate...... mattress were used to provide local heating for the patient. The effects of the methods were identified by comparing the manikin based equivalent temperatures. The optimal thermal comfort level for both patient and medical staff would obtained when two conventional cotton blankets were used with extra...

  12. Vibration and Buckling of Web Plate of the Plate Girder

    OpenAIRE

    高橋, 和雄; 呉, 明強; 中澤, 聡志; 筑紫, 宏之

    1998-01-01

    The vibration and buckling of the web of the plate girder are studied in this paper. The small deflection theory of the thin plate is used. The finite strip method is employed to solve vibration and buckling of the plate girder. Natural frequenies of buckling properties are shown for various plate girder bridges.

  13. Fuel Cell Thermal Management Through Conductive Cooling Plates

    Science.gov (United States)

    Colozza, Anthony J.; Burke, Kenneth A.

    2008-01-01

    An analysis was performed to evaluate the concept of utilizing conductive cooling plates to remove heat from a fuel cell stack, as opposed to a conventional internal cooling loop. The potential advantages of this type of cooling system are reduced stack complexity and weight and increased reliability through the reduction of the number of internal fluid seals. The conductive cooling plates would extract heat from the stack transferring it to an external coolant loop. The analysis was performed to determine the required thickness of these plates. The analysis was based on an energy balance between the thermal energy produced within the stack and the heat removal from the cooling plates. To accomplish the energy balance, the heat flow into and along the plates to the cooling fluid was modeled. Results were generated for various numbers of cells being cooled by a single cooling plate. The results provided cooling plate thickness, mass, and operating temperature of the plates. It was determined that utilizing high-conductivity pyrolitic graphite cooling plates can provide a specific cooling capacity (W/kg) equivalent to or potentially greater than a conventional internal cooling loop system.

  14. Optimizing Casimir torque between corrugated metallic plates

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Robson B. [Universidade Federal Fluminense, Niteroi, RJ (Brazil); Maia Neto, Paulo A. [Instituto de Fisica, Universidade Federal do Rio de Janeiro, RJ (Brazil)

    2013-07-01

    Full text: The Casimir effect plays a major role in micro- and nano-electromechanical systems (MEMS and NEMS). Besides the normal Casimir force between metallic or dielectric plates, the observation of the lateral Casimir force between corrugated plates opens novel possibilities of micro-mechanical control. The lateral force results from breaking the translational symmetry along directions parallel to the plates by imprinting periodic corrugations on both metallic plates. As the rotational symmetry is broken by this geometry, a Casimir torque arises when the corrugations are not aligned. We calculate the Casimir torque between two parallel metallic plates with surface profiles in the form of 'fans' with arbitrary relative spatial orientation. As compared to the case of anisotropic dielectric plates, the torque per unit area is increased by up to three orders of magnitude for a given separation distance. The experiment proposed here can be performed with torsion pendulum techniques for separation distances as large as 1 μm. From the point of view of fundamental physics, this torque makes possible a precise experimental investigation of the non-trivial geometry dependence of the Casimir effect. We follow the scattering approach and calculate the Casimir energy up to second order in the corrugation amplitudes, taking into account nonspecular reflections, polarization mixing and the finite conductivity of the metals. We investigate the experimental conditions that optimize the effect. (author)

  15. Waste minimization in chromium plating industry

    NARCIS (Netherlands)

    Frenzel, Ines

    2005-01-01

    Chromic acid is a strong oxidizing agent and plays an important role in metal finishing and plating industry. Chromate containing waste effluents are toxic and carcinogen and their treatment is chemical, energy and cost intensive. Therefore, waste prevention and waste treatment are in the focus of a

  16. Null controllability of a thermoelastic plate

    Directory of Open Access Journals (Sweden)

    Assia Benabdallah

    2002-01-01

    Full Text Available Thermoelastic plate model with a control term in the thermal equation is considered. The main result in this paper is that with thermal control, locally distributed within the interior and square integrable in time and space, any finite energy solution can be driven to zero at the control time T.

  17. Large Deflections of Elastic Rectangular Plates

    Science.gov (United States)

    Razdolsky, A. G.

    2015-11-01

    It is known that elastic large deflections of thin plates are governed by von Karman nonlinear equations. The analytical solution of these equations in the general case is unfeasible. Samuel Levy, in 1942, showed that large deflections of the rectangular plate can be expressed as a double series of sine-shaped harmonics (deflection harmonics). However, this method gave no way of creating the computer algorithm of solving the problem. The stress function expression taken in the Levy's method must be revised to find the approach that takes into account of all possible products of deflection coefficients. The algorithm of solving the problem for the rectangular plate with an arbitrary aspect ratio under the action of the lateral distributed load is reported in this paper. The approximation of the plate deflection is taken in the form of double series proposed by Samuel Levy. However, the expression for the stress function is presented in the form that incorporates products of deflection coefficients in the explicit form in distinction to the Levy's expression. The number of harmonics in the deflection expression may be arbitrary. The algorithm provides composing the system of governing cubic equations, which includes the deflection coefficients in the explicit form. Solving the equation system is based on using the principle of minimum potential energy. A method of the gradient descent is applied to find the equilibrium state of the plate as the minimum point of the potential energy. A computer program is developed on the basis of the present algorithm. Numerical examples carried out for the plate model with 16 deflection harmonics illustrate the potentialities of the program. The results of solving the examples are presented in the graphical form for the plates with a different aspect ratio and may be used under designing thin-walled elements of airplane and ship structures.

  18. Bending and stretching of plates

    CERN Document Server

    Mansfield, E H; Hemp, W S

    1964-01-01

    The Bending and Stretching of Plates deals with elastic plate theory, particularly on small- and large-deflexion theory. Small-deflexion theory concerns derivation of basic equations, rectangular plates, plates of various shapes, plates whose boundaries are amenable to conformal transformation, plates with variable rigidity, and approximate methods. Large-deflexion theory includes general equations and some exact solutions, approximate methods in large-deflexion theory, asymptotic large-deflexion theories for very thin plates. Asymptotic theories covers membrane theory, tension field theory, a

  19. Casimir densities for parallel plate in the Domain Wall background

    CERN Document Server

    Setare, M R

    2003-01-01

    The Casimir forces on two parallel plates in conformally flat domain wall background due to conformally coupled massless scalar field satisfying mixed boundary conditions on the plates is investigated. In the general case of mixed boundary conditions formulae are derived for the vacuum expectation values of the energy-momentum tensor and vacuum forces acting on boundaries.

  20. Thermal Performance of Thin Type Radiant Floor Heating Combined with Fan-coil Heating%轻薄水地暖与分机盘管联合供暖热工性能研究

    Institute of Scientific and Technical Information of China (English)

    陈英杰; 李维; 陈立楠; 罗汉

    2014-01-01

    An experimental room was setted up for the heating system as research object, the heat source is air-source heat pump, the extreme is thin type radiant floor heating system combined with fan-coil heating system. The floor heating temperature and thermal performance under stable conditions are researched. The electricity consumption of fan-coil heating, radiant floor heating and radiant floor heating with fan-coil were analyzed through the data recorded by the meter. The value of the COP under three ways were compared after the calculation. Results indicate the indoor temperature response speed of the combined heating system is fast. Within the scope of the indoor temperature requirements, the average floor surface temperature is appropriate with less electricity consumption, the combined heating system is more energy-saving and more comfortable.%以空气源热泵为热源、风机盘管与地板辐射为末端的供暖系统作为研究对象,搭建了实验房间,对轻薄水地暖与风机盘管在供暖系统中的升温和稳定工况下的热工性能进行了实验研究,通过电表记录的数据比较了单开风盘连续运行、单开地板供暖连续运行、同时地板与风机盘管联合供暖各自的耗电量,通过计算比较了3种方式下的COP值,得出地板辐射与风机盘管联合供暖的室内温度响应速度快,在室内温度要求范围内,地板表面平均温度适宜、耗电量少,地板辐射与风机盘管联合供暖方式更节能、更舒适。

  1. Space-time as strongly bent plate

    CERN Document Server

    Kokarev, S S

    1999-01-01

    Futher development is made of a consept of space-time as multidimensional elastic plate, proposed earlier in [20,21]. General equilibrium equations, including 4-dimensional tangent stress tensor - energy-momentum tensor of matter - are derived. Comparative analysis of multidimensional elasticity theory (MET) and GR is given. Variational principle, boundary conditions, energy-momentum tensor, matter and space-time signature are reviewed within the context of MET.

  2. Development of a simple radiant heat induced experimental pain model for evaluation of analgesics in normal healthy human volunteers

    Directory of Open Access Journals (Sweden)

    M.U.R Naidu

    2011-01-01

    Full Text Available Objective : Human experimental pain models help to understand the mechanism of the painful conditions and can also be adopted to test analgesic efficacy of drugs. In early phases, the clinical development of new analgesics is hindered due to the lack of reliable tests for the experimental pain models. In the present study, we have developed and validated a simple radiant heat pain model which can be used for future screening of various analgesic agents. Materials and Methods : We have standardized the thermal pain model by recording pain threshold and pain tolerance time in seconds at three different intensities and levels in 24 healthy subjects. Reproducibility of the test procedure was evaluated by recording the pain parameters by two observers on three consecutive days. Validity of model was further tested by evaluating the analgesic effect of tramadol. Results and Conclusions : Use of radiant heat pain model with high intensity and short level was found to produce low variability with coefficient of variation less than 5%. Interobserver and interperiod reproducibility was very good as shown by Bland - Altman plot; with most of the values within ± 2SD. Tramadol produced statistically significant increase in pain threshold time. The newly developed pain model produces a type of experimental pain which is responsive to analgesic effects of tramadol at clinically relevant doses.

  3. Radiant fluxes from on- and off-axis point sources irradiating a circular disc through two different homogeneous isotropic media

    Science.gov (United States)

    Tryka, S.

    2014-07-01

    The multidomain integral equation method is used to calculate fluxes of radiation from various on- and off-axis point sources passing through two different homogeneous isotropic media and striking a surface of a circular disc perpendicular to the optical axes of these sources. This method is dedicated to radiation passing through attenuating or nonattenuating media with a Fresnel interface and is applicable for arbitrary radiation patterns of point sources. The paper presents, firstly, the generalized multidomain integral equation method, expressed by double iterated integrals, for calculating radiant fluxes from arbitrary emitting point sources. This generalized method is simplified then to the form of multidomain single integral equation method applicable for rotationally symmetrical radiation patterns with optical axes perpendicular to the disc. Next, the simplified method is used for computer simulation of radiant fluxes incident on the disc from small Lambertian and Gaussian sources represented by point source models. All numerical results obtained from this simulation have shown high accuracy and efficiency of the presented method. Selected results are illustrated graphically and validated by Optical Software for Layout and Optimization (OSLO) from Lambda Research Corporation. Potential applications of the presented method include optical sensing and metrology, optical coupling, immersion microscopes, light-extraction problems and creative lighting design.

  4. Anterior cervical plating

    Directory of Open Access Journals (Sweden)

    Gonugunta V

    2005-01-01

    Full Text Available Although anterior cervical instrumentation was initially used in cervical trauma, because of obvious benefits, indications for its use have been expanded over time to degenerative cases as well as tumor and infection of the cervical spine. Along with a threefold increase in incidence of cervical fusion surgery, implant designs have evolved over the last three decades. Observation of graft subsidence and phenomenon of stress shielding led to the development of the new generation dynamic anterior cervical plating systems. Anterior cervical plating does not conclusively improve clinical outcome of the patients, but certainly enhances the efficacy of autograft and allograft fusion and lessens the rate of pseudoarthrosis and kyphosis after multilevel discectomy and fusions. A review of biomechanics, surgical technique, indications, complications and results of various anterior cervical plating systems is presented here to enable clinicians to select the appropriate construct design.

  5. Nonlinear analysis of flexible plates lying on elastic foundation

    Directory of Open Access Journals (Sweden)

    Trushin Sergey

    2017-01-01

    Full Text Available This article describes numerical procedures for analysis of flexible rectangular plates lying on elastic foundation. Computing models are based on the theory of plates with account of transverse shear deformations. The finite difference energy method of discretization is used for reducing the initial continuum problem to finite dimensional problem. Solution procedures for nonlinear problem are based on Newton-Raphson method. This theory of plates and numerical methods have been used for investigation of nonlinear behavior of flexible plates on elastic foundation with different properties.

  6. License plate detection algorithm

    Science.gov (United States)

    Broitman, Michael; Klopovsky, Yuri; Silinskis, Normunds

    2013-12-01

    A novel algorithm for vehicle license plates localization is proposed. The algorithm is based on pixel intensity transition gradient analysis. Near to 2500 natural-scene gray-level vehicle images of different backgrounds and ambient illumination was tested. The best set of algorithm's parameters produces detection rate up to 0.94. Taking into account abnormal camera location during our tests and therefore geometrical distortion and troubles from trees this result could be considered as passable. Correlation between source data, such as license Plate dimensions and texture, cameras location and others, and parameters of algorithm were also defined.

  7. Research on metal-plated cellulose nitrate flakes and their infrared / millimeter wave characteristics

    Science.gov (United States)

    Ye, Shu-qin; Zhu, Chen-guang; Wang, Li-hong; Ou'yang, De-hua; Pan, Gong-pei

    2016-10-01

    Copper-plated and silver-plated cellulose nitrate flakes, which were prepared by using chemical plating technology, were used to jam infrared detector and millimeter-wave radar. It was tested for the conductivity and infrared jamming performance of plating and also the RCS (Radar Cross Section) performance of millimeter-wave radar. Test results showed that the prepared metal-plated cellulose nitrate flakes have obvious conductivity, and infrared total radiation energy of silver plating and copper plating had approximately increased 32% and 21% respectively. Through determination, the millimeter-wave reflecting property and RCS of silver-plated cellulose nitrate flakes were higher than that of copper-plated cellulose nitrate flakes. Therefore, silver-plated cellulose nitrate flakes can be used as an effective infrared / millimeter wave composite jamming material.

  8. Imaging plates calibration to X-rays

    Science.gov (United States)

    Curcio, A.; Andreoli, P.; Cipriani, M.; Claps, G.; Consoli, F.; Cristofari, G.; De Angelis, R.; Giulietti, D.; Ingenito, F.; Pacella, D.

    2016-05-01

    The growing interest for the Imaging Plates, due to their high sensitivity range and versatility, has induced, in the last years, to detailed characterizations of their response function in different energy ranges and kind of radiation/particles. A calibration of the Imaging Plates BAS-MS, BAS-SR, BAS-TR has been performed at the ENEA-Frascati labs by exploiting the X-ray fluorescence of different targets (Ca, Cu, Pb, Mo, I, Ta) and the radioactivity of a BaCs source, in order to cover the X-ray range between few keV to 80 keV.

  9. Experimental Research of Solar Radiant Floor Heating System in Cold Area%严寒地区太阳能地板辐射供暖系统实验研究

    Institute of Scientific and Technical Information of China (English)

    崔成辽; 张叶; 焦浩; 赵莹莹; 张志纲; 曾庆萍

    2015-01-01

    乌鲁木齐地区位于中国严寒气候区,冬季采暖期长达6个月,但该地区太阳能资源较为丰富,高达5.4×109~6.2×109 J/m2·a,为太阳能热利用提供了有利条件。在太阳能日辐射强度利用价值高的时段,如何选择与当地气候条件相适应的集热元器件并构筑高集热效率的太阳能热水系统,将直接影响太阳能热利用技术的效果。本研究旨在结合乌鲁木齐冬季供暖的实际情况构筑太阳能地板辐射供暖系统,采用实验方法对太阳能地板辐射供暖系统的性能进行分析,重点分析乌鲁木齐地区冬季供暖期,室外气象条件(太阳辐射强度、室外干球温度、风速等参数)、集热器进出水温度、室内供回水温度等参数的变化规律,得出太阳能地板辐射供暖系统在冬季的运行控制方式,研究结果为乌鲁木齐地区太阳能地板辐射供暖系统的应用提供了基础参考数据。%Urumqi is located in China cold climate zone with the winter heating period of six months, but the local solar energy resources is relatively abundant, ranged from 5.4×109 to 6.2×109 J/m2·a, which provides favorable conditions for solar energy heat utilization. The selction of solar collector and the construction of solar heating system with various local climatic conditions directly influence the effect of solar heat utilization technology. A solar radiant floor heating system is built in Xinjiang University in Urumqi, the performance of the solar radiant floor heating system is analyzed experimentally. The variation of collector’s inlet and outlet water temperature, indoor water supply and return temperature and other parameters with different outdoor meteorological conditions (solar radiation inten -sity, outdoor dry bulb temperature, wind speed and other parameters) are analyzed in details. The operation control method of the solar radiant floor heating system in winter is obtained. The research

  10. Energy

    Science.gov (United States)

    2003-01-01

    Canada, Britain, and Spain. We found that the energy industry is not in crisis ; however, U.S. government policies, laws, dollars, and even public...CEIMAT (Centro de Investagaciones Energeticas , Medioambeintales y Tecnologicas) Research and development Page 3 of 28ENERGY 8/10/04http://www.ndu.edu...meet an emerging national crisis (war), emergency (natural disaster), or major impact event (Y2K). Certain resources are generally critical to the

  11. Casimir force between metal plate and dielectric plate

    Institute of Scientific and Technical Information of China (English)

    刘中柱; 邵成刚; 罗俊

    1999-01-01

    The Casimir effect between metal plate and dielectric plate is discussed with 1+1-dimensional potential model without using cut-off method. Calculation shows that the Casimir force between metal plate and dielectric plate is determined not only by the potential V0, the dielectric thickness and the distance α between the metal plate and dielectric plate, but also by the dimension of the vessel. When α is far less than the dimension of the vessel, the Casimir force Fc∝α(-1); conversely Fc∝α-2. This result is significant for Casimir force experiment.

  12. Light and temperature performance of energy-saving solar greenhouse assembled with color plate%彩钢板保温装配式节能日光温室的温光性能

    Institute of Scientific and Technical Information of China (English)

    孙周平; 黄文永; 李天来; 佟雪娇; 白义奎; 马健

    2013-01-01

    ,which has completely resolved the problem on the year-round vegetable supply, especially in winter in north China. However, the CESG also faces many problems such as uneven distribution of light and temperature in greenhouse, difficulties to achieve automatic control of outside heat preservation covering materials, poor ability of rainproof, snow-proof, wind-proof and fire-proof, and destruction of lots of arable land for greenhouse construction of earth wall and brick wall. To resolve the above problems, a new type of energy-saving solar greenhouse assembled with heat preservation color plate (CPSG) was developed in Lingyuan (latitude 41?20'N, longitude 119?31'E), Liaoning province, China from 2010 to 2012. The light and temperature performances were studied from January to March, 2013.The CPSG was the large scale arched structure with a span of 12 m, a ridge height of 5.5m, a length of 65m, a front roof lighting angle of 41.5°, a front roof covering materials of polyolefin film. The skeleton structure was semi-circular arc, which slide to opening or closing the heat preservation covering materials of rock wool color plate outside, and to move the opening or closing of the rock wool color plate east gable (in the morning) and west gable (in the afternoon) respectively. As a result, the CPSG not only resolved the problem of rain-proof, snow-proof, wind-proof and fire-proof for Chinese traditional solar greenhouse, but also brought about the accurate operation of outside heat preservation color plate. Furthermore, this type of greenhouse adopted water-recycle heat storage-release system (WHSS) and air-underground heat exchange storage-release system(AHESS). WHSS is running 5.5h/d on sunny day and the solar energy storage capacity is 1200kJ/m2 (greenhouse area), which made the greenhouse temperature increase 7-8℃ in winter night. At the same time, solar energy accumulation for AHESS is 221kJ/m2, which shows that two heat storage-release systems may replace the heat

  13. Orifice plate cavitation mechanism and its influencing factors

    Directory of Open Access Journals (Sweden)

    Wan-zheng AI

    2010-09-01

    Full Text Available The orifice plate energy dissipater is an economic and highly efficient dissipater. However, there is a risk of cavitaion around the orifice plate flow. In order to provide references for engineering practice, we examined the cavitation mechanism around the orifice plate and its influencing factors by utilizing mathematical analysis methods to analyze the flow conditions around the orifice plate in view of gas bubble dynamics. Through the research presented in this paper, the following can be observed: The critical radius and the critical pressure of the gas nucleus in orifice plate flow increase with its initial state parameter ; the development speed of bubbles stabilizes at a certain value after experiencing a peak value and a small valley value; and the orifice plate cavitation is closely related to the distribution of the gas nucleus in flow. For computing the orifice plate cavitation number, we ought to take into account the effects of pressure fluctuation. The development time of the gas nucleus from the initial radius to the critical radius is about 10-7-10-5 s; therefore, the gas nucleus has sufficient time to develop into bubbles in the negative half-cycle of flow fluctuation. The orifice critical cavitation number is closely related to the orifice plate size, and especially closely related with the ratio of the orifice plate radius to the tunnel radius. The approximate formula for the critical cavitation number of the square orifice plate that only considers the main influencing factor was obtained by model experiments.

  14. Nuclear reactor alignment plate configuration

    Energy Technology Data Exchange (ETDEWEB)

    Altman, David A; Forsyth, David R; Smith, Richard E; Singleton, Norman R

    2014-01-28

    An alignment plate that is attached to a core barrel of a pressurized water reactor and fits within slots within a top plate of a lower core shroud and upper core plate to maintain lateral alignment of the reactor internals. The alignment plate is connected to the core barrel through two vertically-spaced dowel pins that extend from the outside surface of the core barrel through a reinforcement pad and into corresponding holes in the alignment plate. Additionally, threaded fasteners are inserted around the perimeter of the reinforcement pad and into the alignment plate to further secure the alignment plate to the core barrel. A fillet weld also is deposited around the perimeter of the reinforcement pad. To accomodate thermal growth between the alignment plate and the core barrel, a gap is left above, below and at both sides of one of the dowel pins in the alignment plate holes through with the dowel pins pass.

  15. Outcome of Femoral Plate Osteosynthesis in a Teaching Hospital in ...

    African Journals Online (AJOL)

    Valued eMachines Customer

    The scope of femoral fracture is wide and generally high energy forces are involved with multi- system trauma in ... concentration and packed cell volumes. One hundred and .... Alternatives include traction with or without cast bracing, plate.

  16. Create Your Plate

    Medline Plus

    Full Text Available ... 1 Type 2 About Us Online Community Meal Planning Sign In Search: Search More Sites Search ≡ Are ... Fitness Home Food MyFoodAdvisor Recipes Association Cookbook Recipes Planning Meals Diabetes Meal Plans Create Your Plate Gluten ...

  17. Create Your Plate

    Medline Plus

    Full Text Available ... Create Your Plate is a simple and effective way to manage your blood glucose levels and lose weight. With ... year of delicious meals to help prevent and manage diabetes. Healthy Recipes: ... to your day with this guide. Ways to Give: Wear Your Cause on Your Sleeve - ...

  18. The Plate Tectonics Project

    Science.gov (United States)

    Hein, Annamae J.

    2011-01-01

    The Plate Tectonics Project is a multiday, inquiry-based unit that facilitates students as self-motivated learners. Reliable Web sites are offered to assist with lessons, and a summative rubric is used to facilitate the holistic nature of the project. After each topic (parts of the Earth, continental drift, etc.) is covered, the students will…

  19. Create Your Plate

    Medline Plus

    Full Text Available ... tax-deductible gift today can fund critical diabetes research and support vital diabetes education services that improve the ... way to manage your blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ...

  20. Create Your Plate

    Medline Plus

    Full Text Available ... 1 Type 2 About Us Online Community Meal Planning Sign In Search: Search More Sites Search ≡ Are ... Fitness Home Food MyFoodAdvisor Recipes Association Cookbook Recipes Planning Meals Diabetes Meal Plans Create Your Plate Gluten ...

  1. Create Your Plate

    Medline Plus

    Full Text Available ... tax-deductible gift today can fund critical diabetes research and support vital diabetes education services that improve the ... way to manage your blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ...

  2. Create Your Plate

    Medline Plus

    Full Text Available ... unsweetened tea or coffee. Featured Product Precise Portions® Go Healthy Travel Pack (4/Box) Taking the guesswork ... you are. Now, our best-selling, sectioned to-go plate with easy-sealing lid is offered in ...

  3. Create Your Plate

    Medline Plus

    Full Text Available ... manage portion control wherever you are. Now, our best-selling, sectioned to-go plate with easy-sealing lid is offered in a 4-pack. Whether ... Research & Practice We Are Research Leaders We Support Your Doctor ...

  4. INL HIP Plate Fabrication

    Energy Technology Data Exchange (ETDEWEB)

    B. H. Park; C. R. Clark; J. F. Jue

    2010-02-01

    This document outlines the process used to bond monolithic fuel plates by Hot Isostatic Pressing (HIP). This method was developed at Idaho National Laboratory (INL) for the Reduced Enrichment for Research and Test Reactors (RERTR) program. These foils have been used in a number of irradiation experiments in support of the United States Global Threat Reduction Initiative (GTRI) program.

  5. The Plate Tectonics Project

    Science.gov (United States)

    Hein, Annamae J.

    2011-01-01

    The Plate Tectonics Project is a multiday, inquiry-based unit that facilitates students as self-motivated learners. Reliable Web sites are offered to assist with lessons, and a summative rubric is used to facilitate the holistic nature of the project. After each topic (parts of the Earth, continental drift, etc.) is covered, the students will…

  6. Create Your Plate

    Medline Plus

    Full Text Available ... Planning Meals > Create Your Plate Share: Print Page Text Size: A A A Listen En Español Create ... somewhere in between, you have an easy portion control solution that works. Last Reviewed: October 8, 2015 Last Edited: ... Cost of Diabetes Advocate Toolkit Call to Congress Research & ...

  7. Dynamic response of visco-elastic plates

    Science.gov (United States)

    Kadıoǧlu, Fethi; Tekin, Gülçin

    2016-12-01

    In this study, a comprehensive analysis about the dynamic response characteristics of visco-elastic plates is given. To construct the functional in the Laplace-Carson domain for the analysis of visco-elastic plates based on the Kirchhoff hypothesis, functional analysis method is employed. By using this new energy functional in the Laplace-Carson domain, moment values that are important for engineers can be obtained directly with excellent accuracy and element equations can be written explicitly. Three-element model is considered for modelling the visco-elastic material behavior. The solutions obtained in the Laplace-Carson domain by utilizing mixed finite element formulation are transformed to the time domain using the Durbin's inverse Laplace transform technique. The proposed mixed finite element formulation is shown to be simple to implement and gives satisfactory results for dynamic response of visco-elastic plates.

  8. Wave Damping over a Perforated Plate with Water Chambers

    Institute of Scientific and Technical Information of China (English)

    ZHU Shutang

    2006-01-01

    The movement of waves propagating over a horizontally submerged perforated plate with waterfilled chambers bellow the plate was investigated by using linear potential theory. The analytical solution was compared with laboratory experiments on wave blocking. The analysis of the wave energy dissipation on the perforated bottom surface shows that the effects of the perforated plate on thewave motion depend mainly on the plate porosity, the wave height, and the wave period. The wave number is a complex number when the wave energy dissipation on the perforated plate is considered. The real part of the wave number refers to the spatial periodicity while the imaginary part represents the damping modulus. The characteristics of the wave motion were explored for several possible conditions.

  9. Study on Sublimation Phenomenon of a Horizontal Frost Layer Exposed to an Impinging Jet Flow and Radiant Energy

    OpenAIRE

    稲葉, 英男; 今井, 誠士

    1997-01-01

    冷凍機の蒸発器などの低温熱交換器への着霜は、熱交換器の熱抵抗を著しく増大させ、その性能の低下をもたらすことにより、着霜した熱交換器の性能維持のためには除霜運転が必要となる。著者らは、昇華蒸発現象を利用した新しい除霜法の検討を行っており、水平霜層に対して垂直に湿り低温空気を吹き付ける、いわゆる衝突噴流にさらされた水平霜層の昇華蒸発を利用した除霜挙動を明らかにした。その結果、霜層に平行な強制対流下で除霜する場合と比較して、極めて物質伝達が大きく、短時間での除霜が可能であることが示された。本報は、衝突噴流下で昇華蒸発する霜層にさらに赤外線放射熱エネルギを照射した場合の、昇華蒸発の促進に関する基礎的検討を行うものである。これは、Schmidt や Cunnigham の報告にあるように、霜層の赤外線吸収率が0.98程度と極めて高いことに着目したものである。既報では、水平霜層が平行な強制対流下にさらされる場合について、放射熱エネルギの照射による昇華蒸発促進効果を実験的に検討した。その結果、放射熱エネルギを照射した場合の昇華蒸発量は、放射熱エネルギを照射しない場合に比較して最大10倍程度も増...

  10. Documentation associated with the WESF preparation for receiving 25 cesium capsules from the Applied Radiant Energy Corporation (ARECO)

    Energy Technology Data Exchange (ETDEWEB)

    Pawlak, M.W.

    1996-10-21

    The purpose of this report is to compile all documentation associated with facility preparation of WESF to receive 25 cesium capsules from ARECO. The WESF validated it`s preparedness by completing a facility preparedness review using a performance indicator checklist.

  11. Field tests on human tolerance to (LNG) fire radiant heat exposure, and attenuation effects of clothing and other objects.

    Science.gov (United States)

    Raj, Phani K

    2008-09-15

    A series of field tests exposing mannequins clothed with civilian clothing to a 3m x 3m square liquefied natural gas (LNG) pool fire was conducted. Both single layer clothing and double layer clothing were used. The radiant heat flux incident outside the clothing and incident on the skin covered by clothing were measured using wide-angle radiometers, for durations of 100-200 s (per test). The levels of heat flux incident on the clothing were close to 5 kW/m(2). The magnitude of the radiant heat attenuation factor (AF) across the thickness was determined. AF varies between 2 and higher for cotton and polyester clothing (thickness 0.286-1.347 mm); AF value of 6 was measured for 1.347 mm thickness. Single sheet newspaper held about 5 cm in front of mannequins and exposed to incident flux of 5 kW/m(2) resulted in AF of 5, and AF of 8 with double sheets. AF decreases linearly with increasing heat flux values and linearly increases with thickness. The author exposed himself, in normal civilian clothing (of full sleeve cotton/polyester shirt and jean pants), to radiant heat from a LNG fire. The exposure was for several tens of seconds to heat flux levels ranging from 3.5 kW/m(2) to 5(+) kW/m(2) (exposure times from 25s to 97 s at average heat flux values in the 4 kW/m(2) and 5 kW/m(2)range). Occasionally, he was exposed to (as high as) 7 kW/m(2) for durations of several seconds. He did not suffer any unbearable or even severe pain nor did he experience blisters or burns or any other injury on the unprotected skin of his body. The incident heat fluxes on the author were measured by a hand-held radiometer (with digital display) as well as by strapped on wide-angle radiometers connected to a computer. He could withstand the US regulatory criterion of 5 kW/m(2) (for 30 s) without suffering any damage or burns. Temperature measured on author's skin covered by clothing did not rise above the normal body temperature even after 200 s of exposure to 4 kW/m(2) average heat flux.

  12. Solar energy modulator

    Science.gov (United States)

    Hale, R. R. (Inventor); Mcdougal, A. R.

    1984-01-01

    A module is described with a receiver having a solar energy acceptance opening and supported by a mounting ring along the optic axis of a parabolic mirror in coaxial alignment for receiving solar energy from the mirror, and a solar flux modulator plate for varying the quantity of solar energy flux received by the acceptance opening of the module. The modulator plate is characterized by an annular, plate-like body, the internal diameter of which is equal to or slightly greater than the diameter of the solar energy acceptance opening of the receiver. Slave cylinders are connected to the modulator plate for supporting the plate for axial displacement along the axis of the mirror, therby shading the opening with respect to solar energy flux reflected from the surface of the mirror to the solar energy acceptance opening.

  13. Non-diffuseness of vibration fields in ribbed plates

    DEFF Research Database (Denmark)

    Brunskog, Jonas; Chung, Hyuck

    2011-01-01

    This paper presents numerical simulations of structural intensity in a rib-reinforced plate, investigating the diffuseness. Many prediction models of building and structural acoustics, such as statistical energy analysis or energy flow methods, assume the vibrational wave fields to be diffuse....... However, the diffuseness assumption is not always valid. One such example is a rib-reinforced plate typically found in a lightweight floor with wooden joists. Other examples can be found in aircraft and ship structures. The structural intensity of a ribbed plate is computed at low to mid frequencies using...

  14. Disseny de calefacció amb terra radiant d'una casa a l'horta de Lleida mitjançant energia geotèrmica

    OpenAIRE

    Fillat Sobrino, Jordi

    2008-01-01

    S'ha realitzat el disseny de calefacció d'una vivenda mitjançant energia geotèrmica de baixa temperatura, amb un bescanviador vertical de 80 m de profunditat. El sistema de calefacció és de terra radiant en forma d'espiral.

  15. Sigmund Freud: pioneer in energy healing.

    Science.gov (United States)

    Edwards, Stephen D; Edwards, David J

    2010-02-01

    Energy healing is a popular contemporary term for forms of healing that facilitate a natural healing process through harmonizing, rebalancing, and releasing energy flow disturbed or blocked by disease and illness. Biographical evidence indicates that Freud used physical, suggestive, and radiant forms of energy healing, and that his personal life, metapsychology, and psychoanalysis were founded on dynamic, energetic experiences and conceptualizations. Analysis of Freud's life and work leads to the conclusion that in experience, theory, and practice, Freud typified the traditional role of therapist and was a pioneer in modern forms of energy healing.

  16. Simulation Analysis of Hybrid Radiant Floor Cooling for Railway Station%铁路客运站复合式地板辐射供冷模拟分析

    Institute of Scientific and Technical Information of China (English)

    王胜男; 雷波

    2013-01-01

    以河南周口车站为例,应用EnergyPlus软件建立复合式地板辐射供冷系统和全空气系统模型,分析夏季工况下室内温度等热舒适性参数,并对系统进行能耗分析。研究表明,铁路客运站采用复合式地板辐射供冷系统可以较好的满足热舒适性要求,同时具有良好的节能效果。%With an example of Zhouko railway station in Henan, hybrid radiant floor cooling system and all-air system are simulated by the EnergyPlus software. Indoor air temperature and thermal comfort parameters and energy consumption are analyzed in summer design day. By comparing both of the two systems, the results indicate that the hybrid system can get a better thermal comfort in railway station, and has good effect on energy saving.

  17. MyPlate Food Guide

    Science.gov (United States)

    ... Choosing the Right Sport for You Shyness MyPlate Food Guide KidsHealth > For Teens > MyPlate Food Guide Print ... other sugary drinks. Avoid oversized portions. continue Five Food Groups Different food groups meet different nutrition needs. ...

  18. What Are Growth Plate Injuries?

    Science.gov (United States)

    ... plate injuries are:  Falling down  Competitive sports (like football)  Recreational activities. Other reasons for growth plate injuries are:  Child abuse  Injury from extreme cold (for ...

  19. Contributing to global computing platform: gliding, tunneling standard services and high energy physics application; Contribution aux infrastructures de calcul global: delegation inter plates-formes, integration de services standards et application a la physique des hautes energies

    Energy Technology Data Exchange (ETDEWEB)

    Lodygensky, O

    2006-09-15

    Centralized computers have been replaced by 'client/server' distributed architectures which are in turn in competition with new distributed systems known as 'peer to peer'. These new technologies are widely spread, and trading, industry and the research world have understood the new goals involved and massively invest around these new technologies, named 'grid'. One of the fields is about calculating. This is the subject of the works presented here. At the Paris Orsay University, a synergy emerged between the Computing Science Laboratory (LRI) and the Linear Accelerator Laboratory (LAL) on grid infrastructure, opening new investigations fields for the first and new high computing perspective for the other. Works presented here are the results of this multi-discipline collaboration. They are based on XtremWeb, the LRI global computing platform. We first introduce a state of the art of the large scale distributed systems, its principles, its architecture based on services. We then introduce XtremWeb and detail modifications and improvements we had to specify and implement to achieve our goals. We present two different studies, first interconnecting grids in order to generalize resource sharing and secondly, be able to use legacy services on such platforms. We finally explain how a research community like the community of high energy cosmic radiation detection can gain access to these services and detail Monte Carlos and data analysis processes over the grids. (author)

  20. Zero, Normal and Super-radiant Modes for Scalar and Spinor Fields in Kerr-anti de Sitter Spacetime

    CERN Document Server

    Kenmoku, Masakatsu; Shigemoto, Kazuyasu; Yoon, Jong Hyuk

    2016-01-01

    Zero and normal modes for scalar and spinor fields in Kerr-anti de Sitter spacetime are studied as bound state problem with Dirichlet and Neumann boundary conditions. Zero mode is defined as the momentum near the horizon to be zero: $p_{\\rm H}=\\omega-\\Omega_{\\rm H}m=0$, and is shown not to exist as physical state for both scalar and spinor fields. Physical normal modes satisfy the spectrum condition $p_{\\rm H}>0$ as a result of non-existence of zero mode and the analyticity with respect to rotation parameter $a$ of Kerr-anti de Sitter black hole. Comments on the super-radiant modes and the thermodynamics of black hole are given in relation to the spectrum condition for normal modes. Preliminary numerical analysis on normal modes is presented.

  1. Intense Super-radiant X-rays from a Compact Source using a Nanocathode Array and Emittance Exchange

    CERN Document Server

    Graves, W S; Moncton, D E; Piot, P

    2012-01-01

    A novel method of producing intense short wavelength radiation from relativistic electrons is described. The electrons are periodically bunched at the wavelength of interest enabling in-phase super-radiant emission that is orders of magnitude more intense than that of unbunched electrons. The periodic bunching is achieved in steps beginning with an array of beamlets emitted from a nanoengineered field emission array. The beamlets are then manipulated and converted to a longitudinal density modulation via a transverse to longitudinal emittance exchange. Periodic bunching at short wavelength is shown to be possible, and the partially coherent x-ray properties produced by Inverse Compton scattering from an intense laser are estimated for an example at 13 nm wavelength using a 1.5 MeV electron beam.

  2. Reduced leakage current and improved ferroelectricity in magneto-electric composite ceramics prepared with microwave assisted radiant hybrid sintering

    Directory of Open Access Journals (Sweden)

    Sanjay Kumar Upadhyay

    2015-04-01

    Full Text Available Structural, electrical and magnetic properties of magneto-electric composite ceramics viz., 0.9 BaTi0.95Sn0.05O3 (BTSO- 0.1 Ni0.8Zn0.2Fe2O4 (NZFO prepared with microwave assisted radiant hybrid sintering (MARH are reported. Phase purity and isovalent substitution of Ti4+ by Sn4+ of the samples is confirmed from x-ray diffraction and 119Sn Mossbauer measurements respectively. Significant suppression of leakage current and improvement of ferroelectricity is observed for the composites prepared with MARH. The observed results are explained in terms of uniform dispersion of ferrite (NZFO phase in the ferroelectric (BTSO matrix as evidenced from back-scattered scanning electron micrographs.

  3. Controlling Laminate Plate Elastic Behavior

    OpenAIRE

    Mareš, T.

    2004-01-01

    This paper aims to express the relation of a measure of laminate plate stiffness with respect to the fiber orientation of its plies. The inverse of the scalar product of the lateral displacement of the central plane and lateral loading of the plate is the measure of laminate plate stiffness. In the case of a simply supported rectangular laminate plate this measure of stiffness is maximized, and the optimum orientation of its plies is searched.

  4. Electronic Equipment Cold Plates

    Science.gov (United States)

    1976-04-01

    equations for such a flow regiae. For laainar flow and Moderate teaperature differwwe« between the well «nd coolant, a aodifled Sieder -Tate...con- figuration. The heat-transfer coefficients, therefore, were determined by using both the Sieder -Tate and McAdams equations and the coaputed...values used In the analytical predictions. As with th* previous cold Plates, the Sieder -Tate equation gave too low of values for the heat- transfer

  5. Elastic plate spallation

    Science.gov (United States)

    Oline, L.; Medaglia, J.

    1972-01-01

    The dynamic finite element method was used to investigate elastic stress waves in a plate. Strain displacement and stress strain relations are discussed along with the stiffness and mass matrix. The results of studying point load, and distributed load over small, intermediate, and large radii are reported. The derivation of finite element matrices, and the derivation of lumped and consistent matrices for one dimensional problems with Laplace transfer solutions are included. The computer program JMMSPALL is also included.

  6. Plate Tearing by a Cone

    DEFF Research Database (Denmark)

    Simonsen, Bo Cerup

    1997-01-01

    The present paper is concerned with steady-state plate tearing by a cone. This is a scenario where a cone is forced through a ductile metal plate with a constant lateral tip penetration in a motion in the plane of the plate. The considered process could be an idealisaton of the damage, which...

  7. Plate Tearing by a Cone

    DEFF Research Database (Denmark)

    Simonsen, Bo Cerup

    1998-01-01

    The present paper is concerned with steady-state plate tearing by a cone. This is a scenario where a cone is forced through a ductile metal plate with a constant lateral tip penetration in a motion in the plane of the plate. The considered process could be an idealisation of the damage, which...

  8. Pyroelectric Energy Harvesting: Model and Experiments

    Science.gov (United States)

    2016-05-01

    characterization of the pyroelectric sample was performed with a Radiant Precision Premier II Ferroelectric Tester. The Radiant Vision software...enables many electrical measurements including ferroelectric hysteresis loops, leakage, and capacitance tests. The Radiant system uses a current...conversion cycles. 5.1 Static Testing The pyroelectric sample was tested under static temperature conditions using the heater element and a Radiant

  9. Renewable energy integration into the Australian National Electricity Market: Characterising the energy value of wind and solar generation

    OpenAIRE

    Nicholas Boerema; Merlinde Kay; Iain MacGill

    2010-01-01

    This paper examines how key characteristics of the underlying wind and solar resources may impact on their energy value within the Australian National Electricity Market(NEM). Analysis has been performed for wind generation using half hour NEM data for South Australia over the 2008-9 financial year. The potential integration of large scale solar generation has been modelled using direct normal solar radiant energy measurements from the Bureau of Meteorology for six sites across the NEM. For w...

  10. The Light Velocity Casimir Effect Does the Velocity of Light Increase when Propagating Between the Casimir Plates?

    CERN Document Server

    Ostoma, T; Ostoma, Tom; Trushyk, Mike

    1999-01-01

    We propose experiments that might be set up to detect the increase in the velocity of light in a vacuum in the laboratory frame for photons travelling between (and perpendicular to) the Casimir plates in a vacuum. The Casimir plates are two closely spaced, conductive plates, where an attractive force is observed to exist between the plates called the 'Casimir Force'. We propose that the velocity of light in a vacuum increases when propagating between two transparent Casimir Plates. We call this effect the 'Light Velocity Casimir Effect' or LVC effect. The LVC effect happens because the vacuum energy density in between the plates is lower than that outside the Casimir plates. The conductive plates disallow certain frequencies of electrically charged virtual particles to exist inside the plates, thus lowering the inside vacuum particle density, compared to the density outside the plates. The reduced (electrically charged) virtual particle density results in fewer photon scattering events inside the plates, whic...

  11. Plate tectonics conserves angular momentum

    Directory of Open Access Journals (Sweden)

    C. Bowin

    2009-03-01

    Full Text Available A new combined understanding of plate tectonics, Earth internal structure, and the role of impulse in deformation of the Earth's crust is presented. Plate accelerations and decelerations have been revealed by iterative filtering of the quaternion history for the Euler poles that define absolute plate motion history for the past 68 million years, and provide an unprecedented precision for plate angular rotation variations with time at 2-million year intervals. Stage poles represent the angular rotation of a plate's motion between adjacent Euler poles, and from which the maximum velocity vector for a plate can be determined. The consistent maximum velocity variations, in turn, yield consistent estimates of plate accelerations and decelerations. The fact that the Pacific plate was shown to accelerate and decelerate, implied that conservation of plate tectonic angular momentum must be globally conserved, and that is confirmed by the results shown here (total angular momentum ~1.4 E+27 kgm2s−1. Accordingly, if a plate decelerates, other plates must increase their angular momentums to compensate. In addition, the azimuth of the maximum velocity vectors yields clues as to why the "bend" in the Emperor-Hawaiian seamount trend occurred near 46 Myr. This report summarizes processing results for 12 of the 14 major tectonic plates of the Earth (except for the Juan de Fuca and Philippine plates. Plate accelerations support the contention that plate tectonics is a product of torques that most likely are sustained by the sinking of positive density anomalies due to phase changes in subducted gabbroic lithosphere at depth in the upper lower mantle (above 1200 km depth. The tectonic plates are pulled along by the sinking of these positive mass anomalies, rather than moving at near constant velocity on the crests of convection cells driven by rising heat. These results imply that spreading centers are primarily passive reactive

  12. Vehicle License Plate Recognition Syst

    Directory of Open Access Journals (Sweden)

    Meenakshi,R. B. Dubey

    2012-12-01

    Full Text Available The vehicle license plate recognition system has greater efficiency for vehicle monitoring in automatic zone access control. This Plate recognition system will avoid special tags, since all vehicles possess a unique registration number plate. A number of techniques have been used for car plate characters recognition. This system uses neural network character recognition and pattern matching of characters as two character recognition techniques. In this approach multilayer feed-forward back-propagation algorithm is used. The performance of the proposed algorithm has been tested on several car plates and provides very satisfactory results.

  13. Using plate mapping to examine portion size and plate composition for large and small divided plates.

    Science.gov (United States)

    Sharp, David E; Sobal, Jeffery; Wansink, Brian

    2014-12-01

    Does the size of a plate influence the serving of all items equally, or does it influence the serving of some foods - such as meat versus vegetables - differently? To examine this question, we used the new method of plate mapping, where people drew a meal on a paper plate to examine sensitivity to small versus large three-compartment divided plates in portion size and meal composition in a sample of 109 university students. The total drawn meal area was 37% bigger on large plates than small plates, which showed that the portion of plate coverage did not differ by plate size. Men and women drew bigger vegetable portions and men drew bigger meat portions on large plates when compared to small plates. These results suggest that men and women are differentially sensitive to plate size for overall meal size and for meal composition. Implications for decreasing portion size and improving meal balance are that plate size may influence portion size and change the proportions of foods served.

  14. A MEMS square Chladni plate resonator

    Science.gov (United States)

    Pala, Sedat; Azgın, Kıvanç

    2016-10-01

    This paper presents the design, fabrication and tests of a micro-fabricated MEMS ‘Chladni’ plate resonator. The proposed MEMS resonator has a square plate geometry having a side length of 1400 µm and a height of 35 µm. Its geometry and electrode layout are designed to analyze and test as many modes as possible. The MEMS plate is fabricated using a silicon-on-insulator process with a 35 µm thick silicon layer on a glass substrate. Transverse vibration of the plate is investigated to obtain closed form natural frequencies and mode shapes, which are derived using the Rayleigh-Ritz energy method, with an electrostatic softening effect included. Closed form equations for the calculation of effective stiffness’, masses and natural frequencies of the two modes (mode (1,1) and mode (2,0)-(0,2)) are presented, with and without electrostatic softening. The analytical model is verified for those modes by finite-element simulations, frequency response tests in vacuum and laser Doppler vibrometer (LDV) experiments. The derived model deviates from the finite-element analysis by 3.35% for mode (1,1) and 6.15% for mode (2,0)-(0,2). For verification, the frequency responses of the plates are measured with both electrostatic excitation-detection at around 20 mTorr vacuum ambient and LDV at around 0.364 mTorr vacuum ambient. The resonance frequency and Q-factor of mode (1,1) are measured to be 104.2 kHz and 14 300, respectively. For mode (2,0)-(0,2), the measured resonance frequency and Q-factor are 156.68 kHz and 10 700, respectively. The presented LDV results also support both natural frequencies of interest and corresponding mode shapes of the plate structure.

  15. Development and progress in resistive plate chamber

    Institute of Scientific and Technical Information of China (English)

    CHEN Hong-Fang; WU Jian

    2004-01-01

    Resistive Plate Chamber (RPC) is a robust and low cost gas detector, which is extensively used in high-energy physics, cosmic and astroparticle physics experiments. Over the past twenty years, as a particle detector,RPC has made remarkable progress. The main achievements, features and results of experiemantal tests including R&D and production of the RPCs by several Chinese groups in recent years are reported in this article.

  16. Wave turbulence buildup in a vibrating plate

    CERN Document Server

    Auliel, Maria Ines; Mordant, Nicolas

    2015-01-01

    We report experimental and numerical results on the buildup of the energy spectrum in wave turbulence of a vibrating thin elastic plate. Three steps are observed: first a short linear stage, then the turbulent spectrum is constructed by the propagation of a front in wave number space and finally a long time saturation due to the action of dissipation. The propagation of a front at the second step is compatible with scaling predictions from the Weak Turbulence Theory.

  17. Temperature field of steel plate cooling process after plate rolling

    Directory of Open Access Journals (Sweden)

    Huijun Feng, Lingen Chen, Fengrui Sun

    2015-01-01

    Full Text Available Based on numerical calculation with Matlab, the study on cooling process after plate rolling is carried out, and the temperature field distribution of the plate varying with the time is obtained. The effects of the plate thickness, final rolling temperature, cooling water temperature, average flow rate of the cooling water, carbon content of the plate and cooling method on the plate surface and central temperatures as well as final cooling temperature are discussed. For the same cooling time, the plate surface and central temperatures as well as their temperature difference increase; with the decrease in rolling temperature and the increase in average flow rate of the cooling water, the plate surface and central temperatures decrease. Compared with the single water cooling process, the temperature difference between the plate centre and surface based on intermittent cooling is lower. In this case, the temperature uniformity of the plate is better, and the corresponding thermal stress is lower. The fitting equation of the final cooling temperature with respect to plate thickness, final rolling temperature, cooling water temperature and average flow rate of the cooling water is obtained.

  18. Real Plates and Dubious Microplates

    Science.gov (United States)

    Kogan, M. G.; Steblov, G. M.

    2008-12-01

    From the onset of plate tectonics, the existence of most of the plates was never put in doubt, although the boundaries of some plates, like Africa, were later revised. There are however, two microplates in northeast Asia, the Amurian and Okhotsk, whose existence and the sense of rotation was revised several times. The rms value of plate-residual GPS velocities is 0.5-0.9 mm/a for sets of stations representing the motion of the following plates: Antarctic, Australian, Eurasian, North American, Nubian, Pacific, and South American. This value can be regarded as an upper bound on deviation of real plates from infinite stiffness. The rms value of plate-residual GPS velocities is 1.2-1.8 mm/a for the Indian, Nazca, and Somalian plates. Higher rms values for India and Nazca are attributed to the noisier data. The higher rms value for Somalia appears to arise from the distributed deformation to the east of the East African Rift; whether this statement is true can only be decided from observations of denser network in the future. From the analysis of plate-residual GPS velocities, the Canadian Arctic and northeastern Siberia belong to the North American plate. The detailed GPS survey on Sakhalin Island shows that the Sea of Okhotsk region also belongs to the North American plate while the region to the west of it belongs to the Eurasian plate. These results provide a constraint on the geometry of the North American plate and put in doubt the existence of smaller plates in northeast Asia.

  19. Plate Full of Color

    Centers for Disease Control (CDC) Podcasts

    2008-08-04

    The Eagle Books are a series of four books that are brought to life by wise animal characters - Mr. Eagle, Miss Rabbit, and Coyote - who engage Rain That Dances and his young friends in the joy of physical activity, eating healthy foods, and learning from their elders about health and diabetes prevention. Plate Full of Color teaches the value of eating a variety of colorful and healthy foods.  Created: 8/4/2008 by National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP).   Date Released: 8/5/2008.

  20. Dynamics of Tectonic Plates

    CERN Document Server

    Pechersky, E; Sadowski, G; Yambartsev, A

    2014-01-01

    We suggest a model that describes a mutual dynamic of tectonic plates. The dynamic is a sort of stick-slip one which is modeled by a Markov random process. The process defines a microlevel of the dynamic. A macrolevel is obtained by a scaling limit which leads to a system of integro-differential equations which determines a kind of mean field systems. Conditions when Gutenberg-Richter empirical law are presented on the mean field level. These conditions are rather universal and do not depend on features of resistant forces.

  1. Dynamics of Tectonic Plates

    OpenAIRE

    2014-01-01

    We suggest a model that describes a mutual dynamic of tectonic plates. The dynamic is a sort of stick-slip one which is modeled by a Markov random process. The process defines a microlevel of the dynamic. A macrolevel is obtained by a scaling limit which leads to a system of integro-differential equations which determines a kind of mean field systems. Conditions when Gutenberg-Richter empirical law are presented on the mean field level. These conditions are rather universal and do not depend ...

  2. Standard performance tests of collectors of solar thermal energy: A selectively coated, flat-plate copper collector with one transparent cover and a tube-to-tube spacing of 3-7/8 inches

    Science.gov (United States)

    1976-01-01

    Basic test results are given of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes, and coolant flow rates. Collector efficiency is correlated in terms of inlet temperature and flux level.

  3. Standardized performance tests of collectors of solar thermal energy: A selectively coated, flat-plate copper collector with one transparent cover and a tube-to-tube spacing of 5 5/8 inches

    Science.gov (United States)

    1976-01-01

    This preliminary data report gives basic test results of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and coolant flow rates. Collector efficiency is correlated in terms of inlet temperature and flux level.

  4. Resistive Plate Chamber Efficiency & Rate Capability Analysis

    Science.gov (United States)

    Candocia, Max

    2012-10-01

    Bakelite-based resistive plate chambers (RPCs) are particle detectors commonly used in muon trigger systems for high-energy physics experiments. Bakelite RPCs combine fast response, sufficient position resolution and low cost, and they can be operated at instantaneous background rates up to approximately 1.5 kHz/cm^2. Current and future collider experiments will demand operation of trigger RPCs under background rates higher than what is currently achieved. The rate capability is related to the bulk and surface conductivities of the Bakelite material used for the plates bordering the active gas volume in the RPCs. At the LHC and RHIC, these surfaces are coated with linseed oil, which lowers the surface resistivity of the Bakelite, which, to a point, improves the rate capability of the detectors. We have doped our own plates with various concentrations of carbon black. Over the past year we have tested RPCs with Bakelite plates of different resistivity using cosmic ray muons and radioactive Fe55 sources to emulate different levels of background in the detector. Results on the RPC efficiencies at different background rates and for different Bakelite coatings will be presented.

  5. Quantitative tests for plate tectonics on Venus

    Science.gov (United States)

    Kaula, W. M.; Phillips, R. J.

    1981-01-01

    Quantitative comparisons are made between the characteristics of plate tectonics on the earth and those which are possible on Venus. Considerations of the factors influencing rise height and relating the decrease in rise height to plate velocity indicate that the rate of topographic dropoff from spreading centers should be about half that on earth due to greater rock-fluid density contrast and lower temperature differential between the surface and interior. Statistical analyses of Pioneer Venus radar altimetry data and global earth elevation data is used to identify 21,000 km of ridge on Venus and 33,000 km on earth, and reveal Venus ridges to have a less well-defined mode in crest heights and a greater concavity than earth ridges. Comparison of the Venus results with the spreading rates and associated heat flow on earth reveals plate creation rates on Venus to be 0.7 sq km/year or less and indicates that not more than 15% of Venus's energy is delivered to the surface by plate tectonics, in contrast to values of 2.9 sq km a year and 70% for earth.

  6. CMS Resistive plate Champers

    CERN Document Server

    Zainab, Karam

    2013-01-01

    There are many types of gas detectors which are used in CERN in LHC project, There is a main parts for the gas detectors which must be in all gas detectors types like Multiwire proportional chambers, such as the micromesh gaseous structure chamber (the MicroMegas), Gas-electron multiplier (GEM) detector, Resistive Plate Champers... Compact Muon Solenoid (CMS) experiment detecting muons which are powerful tool for recognizing signatures of interesting physics processes. The CMS detector uses: drift tube (DT), cathode strip chamber (CSC) and resistive plate chamber (RPC). Building RPC’s was my project in summer student program (hardware). RPC’s have advantages which are triggering detector and Excellent time resolution which reinforce the measurement of the correct beam crossing time. RPC’s Organized in stations :  RPC barrel (RB) there are 4 stations, namely RB1, RB2, RB3, and RB4  While in the RPC endcap (RE) the 3 stations are RE1, RE2, and RE3. In the endcaps a new starion will be added and this...

  7. A lumped mass finite element method for vibration analysis of elastic plate-plate structures

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    The fully discrete lumped mass finite element method is proposed for vibration analysis of elastic plate-plate structures.In the space directions,the longitudinal displacements on plates are discretized by conforming linear elements,and the transverse displacements are discretized by the Morley element.By means of the second order central difference for discretizing the time derivative and the technique of lumped masses,a fully discrete lumped mass finite element method is obtained,and two approaches to choosing the initial functions are also introduced.The error analysis for the method in the energy norm is established,and some numerical examples are included to validate the theoretical analysis.

  8. Localised Plate Motion on Venus

    Science.gov (United States)

    Ghail, R. C.

    1996-03-01

    The volcanic and tectonic features observed in Dali Vinculum, Parga Vinculum and Imdr Regio are concentrated at long, narrow, curvilinear zones, with relatively minor volcanism and tectonism between these zones. These zones, whilst more diffuse than terrestrial plate boundaries, nevertheless define the margins of tectonic plates. In contrast to Earth, however, it appears that venusian plates are neither created nor destroyed by lateral motion. Rather, plates are thinned and intruded at vincula plate boundaries, vertically accreted by small-scale intra-plate (planitia) volcanism and perhaps destroyed by delamination of thickened crust in tesserae and montane regions such as Thetis Regio and Ishtar Terra. The diversity in age both between and within these three areas together with the evidence for infrequent, small scale resurfacing in the planitiae are difficult to reconcile with a non-uniformitarian geological process.

  9. Tectonics of the Easter plate

    Science.gov (United States)

    Engeln, J. F.; Stein, S.

    1984-01-01

    A new model for the Easter plate is presented in which rift propagation has resulted in the formation of a rigid plate between the propagating and dying ridges. The distribution of earthquakes, eleven new focal mechanisms, and existing bathymetric and magnetic data are used to describe the tectonics of this area. Both the Easter-Nazca and Easter-Pacific Euler poles are sufficiently close to the Easter plate to cause rapid changes in rates and directions of motion along the boundaries. The east and west boundaries are propagating and dying ridges; the southwest boundary is a slow-spreading ridge and the northern boundary is a complex zone of convergent and transform motion. The Easter plate may reflect the tectonics of rift propagation on a large scale, where rigid plate tectonics requires boundary reorientation. Simple schematic models to illustrate the general features and processes which occur at plates resulting from large-scale rift propagation are used.

  10. Tectonics of the Easter plate

    Science.gov (United States)

    Engeln, J. F.; Stein, S.

    1984-01-01

    A new model for the Easter plate is presented in which rift propagation has resulted in the formation of a rigid plate between the propagating and dying ridges. The distribution of earthquakes, eleven new focal mechanisms, and existing bathymetric and magnetic data are used to describe the tectonics of this area. Both the Easter-Nazca and Easter-Pacific Euler poles are sufficiently close to the Easter plate to cause rapid changes in rates and directions of motion along the boundaries. The east and west boundaries are propagating and dying ridges; the southwest boundary is a slow-spreading ridge and the northern boundary is a complex zone of convergent and transform motion. The Easter plate may reflect the tectonics of rift propagation on a large scale, where rigid plate tectonics requires boundary reorientation. Simple schematic models to illustrate the general features and processes which occur at plates resulting from large-scale rift propagation are used.

  11. Thermal Analysis of Thin Plates Using the Finite Element Method

    Science.gov (United States)

    Er, G. K.; Iu, V. P.; Liu, X. L.

    2010-05-01

    The isotropic thermal plate is analyzed with finite element method. The solution procedure is presented. The elementary stiffness matrix and loading vector are derived rigorously with variation principle and the principle of minimum potential energy. Numerical results are obtained based on the derived equations and tested with available exact solutions. The problems in the finite element analysis are figured out. It is found that the finite element solutions can not converge as the number of elements increases around the corners of the plate. The derived equations presented in this paper are fundamental for our further study on more complicated thermal plate analysis.

  12. Air-to-Water Heat Pumps With Radiant Delivery in Low-Load Homes

    Energy Technology Data Exchange (ETDEWEB)

    Backman, C.; German, A.; Dakin, B.; Springer, D.

    2013-12-01

    Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump (AWHP) systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

  13. Air-to-Water Heat Pumps With Radiant Delivery in Low-Load Homes

    Energy Technology Data Exchange (ETDEWEB)

    Backman, C. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); German, A. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Dakin, B. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Springer, D. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2013-12-01

    Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

  14. Applicability of concrete slab radiant cooling air conditioning system to subtropical zone%混凝土楼板辐射供冷空调系统在亚热带地区的适用性

    Institute of Scientific and Technical Information of China (English)

    黄伟; 李继路; 刘谨

    2012-01-01

    以广州地区某办公建筑为例,评估了混凝土楼板辐射供冷空调系统的满负荷能效比.计算分析了混凝土楼板辐射供冷的热物理特性、夜间蓄冷损耗以及夜间维持房间正压的冷损耗等,并最终得出混凝土楼板辐射供冷空调系统的综合能耗比.结果表明,混凝土楼板辐射供冷空调系统在亚热带地区的应用不具有明显优势.%Taking an office building in Guangzhou as an example, evaluates the full-load energy efficiency ratio. Analyses the thermal-physical characteristics, calculates the cooling losses in the cooling storage and for maintaining the room positive pressure during the night, and finally obtains the integrated energy efficiency ratio. The results indicate that the concrete slab radiant cooling system does not have a notable advantage to be employed in the subtropical zone.

  15. Analysis of Flat-Plate Solar Array and Solar Lantern

    Directory of Open Access Journals (Sweden)

    P. L. N. V. Aashrith

    2014-05-01

    Full Text Available A very detailed theortical analysis of a solar array has been carried out based on established values of solar radiation data to predict the performance of solar lamp . The analysis is based on established theory about flat-plate collectors. Top heat loss coefficient (Ut, Bottom heat loss coefficient (Ub, Overall heat loss coefficient (Ul, Useful energy (Qu, efficiency (hp of the flat-plate solar array and efficiency (hl of the solar lantern has been calculated.

  16. Aluminum Manganese Molten Salt Plating

    Science.gov (United States)

    2006-06-01

    Dry fixture thoroughly with the air gun. Be especially careful to dry water out of crevices. Note: water is a contaminant to the plating process...easily destroyed if blown with the air. Be especially careful to dry water out of crevices. Note: water is a contaminant to the plating process and...especially careful to dry water out of crevices. 13. Carefully remove part from fixture. If residual plating solution is present at attachments points

  17. Experimental investigation of the influence of the air jet trajectory on convective heat transfer in buildings equipped with air-based and radiant cooling systems

    DEFF Research Database (Denmark)

    Le Dreau, Jerome; Heiselberg, Per; Jensen, Rasmus Lund

    2015-01-01

    The complexity and diversity of airflow in buildings make the accurate definition of convective heat transfer coefficients (CHTCs) difficult. In a full-scale test facility, the convective heat transfer of two cooling systems (active chilled beam and radiant wall) has been investigated under steady......-state and dynamic conditions. With the air-based cooling system, a dependency of the convective heat transfer on the air jet trajectory has been observed. New correlations have been developed, introducing a modified Archimedes number to account for the air flow pattern. The accuracy of the new correlations has been...... evaluated to±15%. Besides the study with an air-based cooling system, the convective heat transfer with a radiant cooling system has also been investigated. The convective flow at the activated surface is mainly driven by natural convection. For other surfaces, the complexity of the flow and the large...

  18. Study on the Influence of Piloti on Mean Radiant Temperature in Residential Blocks by 3-D Unsteady State Heat Balance Radiation Calculation

    Institute of Scientific and Technical Information of China (English)

    TianYu Xi; JianHua Ding; Hong Jin

    2014-01-01

    Piloti is commonly used in tropical and subtropical climate zones to get high wind velocity and create shadowed areas in order to optimize the living environment of residential blocks, but there are few studies to reveal the influence of piloti on the radiant environment of residential blocks systematically. Taking the city of Guangzhou as an example, using 3-D Unsteady State Heat Balance Radiation Calculation Method, this paper shows that the mean radiant temperature ( MRT) under piloti area increases with the increase of piloti ratio, and especially when piloti ratio is equal to 100%, the MRT increase trend becomes sharp. The MRT of exposed area decreases with the increase of piloti ratio, especially when piloti ratio reaches 100%, the decrease trend of MRT becomes sharp, which offers the reference for the study on piloti design in subtropical climate zones and further research on living environment by CFD simulation in residential blocks.

  19. Glass-bead peen plating

    Science.gov (United States)

    Graves, J. R.

    1974-01-01

    Peen plating of aluminum, copper, and nickel powders was investigated. Only aluminum was plated successfully within the range of peen plating conditions studied. Optimum plating conditions for aluminum were found to be: (1) bead/powder mixture containing 25 to 35% powder by weight, (2) peening intensity of 0.007A as measured by Almen strip, and (3) glass impact bead diameter of at least 297 microns (0.0117 inches) for depositing-100 mesh aluminum powder. No extensive cleaning or substrate preparation is required beyond removing loose dirt or heavy oil.

  20. Multipactor saturation in parallel-plate waveguides

    Energy Technology Data Exchange (ETDEWEB)

    Sorolla, E.; Mattes, M. [Ecole Polytechnique Federale de Lausanne, Laboratoire d' Electromagnetisme et d' Acoustique (LEMA), Station 11, CH-1015 Lausanne (Switzerland)

    2012-07-15

    The saturation stage of a multipactor discharge is considered of interest, since it can guide towards a criterion to assess the multipactor onset. The electron cloud under multipactor regime within a parallel-plate waveguide is modeled by a thin continuous distribution of charge and the equations of motion are calculated taking into account the space charge effects. The saturation is identified by the interaction of the electron cloud with its image charge. The stability of the electron population growth is analyzed and two mechanisms of saturation to explain the steady-state multipactor for voltages near above the threshold onset are identified. The impact energy in the collision against the metal plates decreases during the electron population growth due to the attraction of the electron sheet on the image through the initial plate. When this growth remains stable till the impact energy reaches the first cross-over point, the electron surface density tends to a constant value. When the stability is broken before reaching the first cross-over point the surface charge density oscillates chaotically bounded within a certain range. In this case, an expression to calculate the maximum electron surface charge density is found whose predictions agree with the simulations when the voltage is not too high.

  1. Intermittent plate tectonics?

    Science.gov (United States)

    Silver, Paul G; Behn, Mark D

    2008-01-04

    Although it is commonly assumed that subduction has operated continuously on Earth without interruption, subduction zones are routinely terminated by ocean closure and supercontinent assembly. Under certain circumstances, this could lead to a dramatic loss of subduction, globally. Closure of a Pacific-type basin, for example, would eliminate most subduction, unless this loss were compensated for by comparable subduction initiation elsewhere. Given the evidence for Pacific-type closure in Earth's past, the absence of a direct mechanism for termination/initiation compensation, and recent data supporting a minimum in subduction flux in the Mesoproterozoic, we hypothesize that dramatic reductions or temporary cessations of subduction have occurred in Earth's history. Such deviations in the continuity of plate tectonics have important consequences for Earth's thermal and continental evolution.

  2. VISAS AND GREEN PLATES

    CERN Multimedia

    2000-01-01

    From 3 April 2000, all questions relating to visa requests for Switzerland, France, or Russia for a member of the personnel must be addressed to Ms. Agnita Querrou (telephone 72838, office 5-2-019, e-mail Agnita.Querrou@cern.ch).The Users' Office continues to deal with requests for letters of invitation and questions concerning visas for users in EP Division.Questions relating to removals, requests for green plates, to privileges of members of the personnel and to the importation of vehicles are still dealt with by Ms Zuzana Miller (telephone 79257, office 33-1-017, e-mail Zuzana.Muller@cern.ch) and Ms Joëlle Belleman (telephone 73962, office 33-1-019, e-mail Joelle.Belleman@cern.ch).

  3. Plate osteosynthesis of simple forearm fractures : LCP versus DC plates

    NARCIS (Netherlands)

    Stevens, Charles Tjerk; Ten Duis, Henk Jan

    2008-01-01

    The aim of this study was to compare the time to radiological bony union of simple A-type fractures of the forearm, treated with either a locking compression plate (LCP) or a dynamic compression plate (DCP). For each fracture, the relation between the use of compression and radiological healing time

  4. Plate osteosynthesis of simple forearm fractures : LCP versus DC plates

    NARCIS (Netherlands)

    Stevens, Charles Tjerk; Ten Duis, Henk Jan

    The aim of this study was to compare the time to radiological bony union of simple A-type fractures of the forearm, treated with either a locking compression plate (LCP) or a dynamic compression plate (DCP). For each fracture, the relation between the use of compression and radiological healing time

  5. Doorway states in nuclear reactions as a manifestation of the "super-radiant" mechanism

    CERN Document Server

    Auerbach, N

    2007-01-01

    A mechanism is considered for generating doorway states and intermediate structure in low-energy nuclear reactions as a result of collectivization of widths of unstable intrinsic states coupled to common decay channels. At the limit of strong continuum coupling, the segregation of broad (''super-radiating") and narrow (''trapped") states occurs revealing the separation of direct and compound processes. We discuss the conditions for the appearance of intermediate structure in this process and doorways related to certain decay channels.

  6. Quantitative assessment of the relationship between radiant heat exposure and protective performance of multilayer thermal protective clothing during dry and wet conditions.

    Science.gov (United States)

    Fu, M; Weng, W G; Yuan, H Y

    2014-07-15

    The beneficial effect of clothing on a person is important to the criteria for people exposure to radiant heat flux from fires. The thermal protective performance of multilayer thermal protective clothing exposed to low heat fluxes during dry and wet conditions was studied using two designed bench-scale test apparatus. The protective clothing with four fabric layers (outer shell, moisture barrier, thermal linear and inner layer) was exposed to six levels of thermal radiation (1, 2, 3, 5, 7 and 10kW/m(2)). Two kinds of the moisture barrier (PTFE and GoreTex) with different vapor permeability were compared. The outside and inside surface temperatures of each fabric layer were measured. The fitting analysis was used to quantitatively assess the relationship between the temperature of each layer during thermal exposure and the level of external heat flux. It is indicated that there is a linear correlation between the temperature of each layer and the radiant level. Therefore, a predicted equation is developed to calculate the thermal insulation of the multilayer clothing from the external heat flux. It can also provide some useful information on the beneficial effects of clothing for the exposure criteria of radiant heat flux from fire.

  7. Spectral radiant power measurements of VUV and soft x-ray sources using the electron storage ring BESSY as a radiometric standard source.

    Science.gov (United States)

    Fischer, J; Kühne, M; Wende, B

    1984-12-01

    A method is described for measuring the spectral radiant power of VUV and soft x-ray sources using the electron storage ring BESSY as a radiometric standard source of calculable spectral radiant power and degree of polarization. An ellipsoidal grazing incidence mirror stigmatically images the stored electrons or the source under investigation in equal optical conditions into a toroidal grating monochromator. The monochromator can be rotated around its optical axis in UHV conditions to account for different degrees of polarization of the two sources. The accuracy presently available with this method is demonstrated by a measurement of the spectral concentration of radiant intensity of a laser-produced tungsten plasma in the wavelength range between 7 and 100 nm with an overall uncertainty of 10%. A detailed analysis of the contributions to this uncertainty shows that the major part of it is caused by the presently uncertain knowledge of the polarizing properties of the radiometric instrumentation and by the uncertainty of the correction procedure which accounts for the influence of higher diffraction orders of the monochromator grating. The results of the radiation measurements of the laser-produced tungsten plasma let us expect that this source type has the potential to serve as a radiometric transfer standard in the VUV and soft x-ray range below 100 nm.

  8. COMPACT SUPPORT THIN PLATE SPLINE ALGORITHM

    Institute of Scientific and Technical Information of China (English)

    Li Jing; Yang Xuan; Yu Jianping

    2007-01-01

    Common tools based on landmarks in medical image elastic registration are Thin Plate Spline (TPS) and Compact Support Radial Basis Function (CSRBF). TPS forces the corresponding landmarks to exactly match each other and minimizes the bending energy of the whole image. However,in real application, such scheme would deform the image globally when deformation is only local.CSRBF needs manually determine the support size, although its deformation is limited local. Therefore,to limit the effect of the deformation, new Compact Support Thin Plate Spline algorithm (CSTPS) is approached, analyzed and applied. Such new approach gains optimal mutual information, which shows its registration result satisfactory. The experiments also show it can apply in both local and global elastic registration.

  9. Electroless nickel plating on optical fiber probe

    Institute of Scientific and Technical Information of China (English)

    Li Huang; Zhoufeng Wang; Zhuomin Li; Wenli Deng

    2009-01-01

    As a component of near-field scanning optical microscope (NSOM),optical fiber probe is an important factor influncing the equipment resolution.Electroless nickel plating is introduced to metallize the optical fiber probe.The optical fibers are etched by 40% HF with Turner etching method.Through pretreatment,the optical fiber probe is coated with Ni-P film by clectrolcss plating in a constant temperature water tank.Atomic absorption spectrometry (AAS),scanning electron microscopy (SEM),and energy dispersive X-ray spectrometry (EDXS) are carried out to charaeterizc the deposition on fiber probe.We have rcproducibly fabricated two kinds of fiber probes with a Ni-P fihn:aperture probe and apertureless probe.In addition,reductive particle transportation on the surface of fiber probe is proposed to explain the cause of these probes.

  10. Plate tectonics, damage and inheritance.

    Science.gov (United States)

    Bercovici, David; Ricard, Yanick

    2014-04-24

    The initiation of plate tectonics on Earth is a critical event in our planet's history. The time lag between the first proto-subduction (about 4 billion years ago) and global tectonics (approximately 3 billion years ago) suggests that plates and plate boundaries became widespread over a period of 1 billion years. The reason for this time lag is unknown but fundamental to understanding the origin of plate tectonics. Here we suggest that when sufficient lithospheric damage (which promotes shear localization and long-lived weak zones) combines with transient mantle flow and migrating proto-subduction, it leads to the accumulation of weak plate boundaries and eventually to fully formed tectonic plates driven by subduction alone. We simulate this process using a grain evolution and damage mechanism with a composite rheology (which is compatible with field and laboratory observations of polycrystalline rocks), coupled to an idealized model of pressure-driven lithospheric flow in which a low-pressure zone is equivalent to the suction of convective downwellings. In the simplest case, for Earth-like conditions, a few successive rotations of the driving pressure field yield relic damaged weak zones that are inherited by the lithospheric flow to form a nearly perfect plate, with passive spreading and strike-slip margins that persist and localize further, even though flow is driven only by subduction. But for hotter surface conditions, such as those on Venus, accumulation and inheritance of damage is negligible; hence only subduction zones survive and plate tectonics does not spread, which corresponds to observations. After plates have developed, continued changes in driving forces, combined with inherited damage and weak zones, promote increased tectonic complexity, such as oblique subduction, strike-slip boundaries that are subparallel to plate motion, and spalling of minor plates.

  11. Epitaxial growth of thick 4H?SiC layers in a vertical radiant-heating reactor

    Science.gov (United States)

    Tsuchida, H.; Kamata, I.; Jikimoto, T.; Izumi, K.

    2002-04-01

    A vertical radiant-heating reactor has been developed for thick silicon carbide (SiC) epitaxial growth, in which the susceptor and substrates are heated by radiation from the hot wall. The benefit of the heating and sample-holding method is demonstrated by improvements in the curvature of crystal bending and FWHM of X-ray ω-rocking curves followed by epitaxial growth. The typical growth rate is 13-16 μm/h at 1530-1550°C at the susceptor top under reduced pressure as low as 50-70 mbar. Low background doping at low 10 13 cm -3 ( Nd- Na) was achieved, and some of the 4H-SiC epilayers exhibited a high resistivity. We also succeeded in growing a 4H-SiC epilayer over 240 μm-thick with minimal surface roughness. Little sign of impurities was observed by low-temperature photoluminescence (LTPL), and no impurities (Al, B, Ti, V and Cr) exceeding 1×10 14 cm -3 were found by secondary ion mass spectroscopy (SIMS) for a 150 μm-thick 4H-SiC epilayer. Thickness and doping uniformity along the gas flow of ˜5% and ˜11%, respectively, were obtained for 2-in substrates. Molten KOH etching analysis revealed that some of the micropipes were dissociated into closed core screw dislocations during epitaxial growth. The electrical performance of high-voltage devices was also demonstrated.

  12. Modeling of mean radiant temperature based on comparison of airborne remote sensing data with surface measured data

    Science.gov (United States)

    Chen, Yu-Cheng; Chen, Chih-Yu; Matzarakis, Andreas; Liu, Jin-King; Lin, Tzu-Ping

    2016-06-01

    Assessment of outdoor thermal comfort is becoming increasingly important due to the urban heat island effect, which strongly affects the urban thermal environment. The mean radiant temperature (Tmrt) quantifies the effect of the radiation environment on humans, but it can only be estimated based on influencing parameters and factors. Knowledge of Tmrt is important for quantifying the heat load on human beings, especially during heat waves. This study estimates Tmrt using several methods, which are based on climatic data from a traditional weather station, microscale ground surface measurements, land surface temperature (LST) and light detection and ranging (LIDAR) data measured using airborne devices. Analytical results reveal that the best means of estimating Tmrt combines information about LST and surface elevation information with meteorological data from the closest weather station. The application in this method can eliminate the inconvenience of executing a wide range ground surface measurement, the insufficient resolution of satellite data and the incomplete data of current urban built environments. This method can be used to map a whole city to identify hot spots, and can be contributed to understanding human biometeorological conditions quickly and accurately.

  13. Orifice plate cavitation mechanism and its influencing factors

    Institute of Scientific and Technical Information of China (English)

    Wan-zheng AI; Tian-ming DING

    2010-01-01

    The orifice plate energy dissipater is an economic and highly efficient dissipater.However,there is a risk of cavitaion around the orifice plate flow.In order to provide references for engineering practice,we examined the cavitation mechanism around the orifice plate and its influencing factors by utilizing mathematical analysis methods to analyze the flow conditions around the orifice plate in view of gas bubble dynamics.Through the research presented in this paper,the following can be observed:The critical radius and the critical pressure of the gas nucleus in orifice plate flow increase with its initial state parameter τ0;the development speed of bubbles stabilizes at a certain value after experiencing a peak value and a small valley value;and the orifice plate cavitation is closely related to the distribution of the gas nucleus in flow.For computing the orifice plate cavitation number,we ought to take into account the effects of pressure fluctuation.The development time of the gas nucleus from the initial radius to the critical radius is about10-7-10-5 s;therefore,the gas nucleus has sufficient time to develop into bubbles in the negative half-cycle of flow fluctuation.The orifice critical cavitation number is closely related to the orifice plate size,and especially closely related with the ratio of the orifice plate radius to the tunnel radius.The approximate formula for the critical cavitation number of the square orifice plate that only considers the main influencing factor was obtained by model experiments.

  14. LED Surgical Task Lighting Scoping Study: A Hospital Energy Alliance Project

    Energy Technology Data Exchange (ETDEWEB)

    Tuenge, Jason R.

    2011-01-17

    Tungsten-halogen (halogen) lamps have traditionally been used to light surgical tasks in hospitals, even though they are in many respects ill-suited to the application due to the large percentage of radiant energy outside the visible spectrum and issues with color rendering/quality. Light-emitting diode (LED) technology offers potential for adjustable color and improved color rendition/quality, while simultaneously reducing side-effects from non-visible radiant energy. It also has the potential for significant energy savings, although this is a fairly narrow application in the larger commercial building energy use sector. Based on analysis of available products and Hospital Energy Alliance member interest, it is recommended that a product specification and field measurement procedure be developed for implementation in demonstration projects.

  15. Design methodology and criteria for daylight and thermal comfort in nearly-zero energy office buildings in Nordic climate

    DEFF Research Database (Denmark)

    Karlsen, Line Røseth

    The objective of this PhD thesis was to arrange for an integrated building design with respect to thermal comfort, daylighting and energy use, applicable for office buildings in Nordic climate. In order to achieve this, it is suggested that modelling of mean radiant temperature (MRT) should...

  16. Casimir Effect for Dielectric Plates

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    We generalize Kupisewska method to the three-dimensional system and another derivation of the Casimir effect between two dielectric plates is presented based on the explicit quantization of the electromagnetic field in the presence of dielectrics, where the physical meaning of "evanescent mode" is discussed. The Lifshitz's formula is rederived perfect metallic plates will the evanescent modes become unimportant.

  17. Micro-channel plate detector

    Science.gov (United States)

    Elam, Jeffrey W.; Lee, Seon W.; Wang, Hsien -Hau; Pellin, Michael J.; Byrum, Karen; Frisch, Henry J.

    2015-09-22

    A method and system for providing a micro-channel plate detector. An anodized aluminum oxide membrane is provided and includes a plurality of nanopores which have an Al coating and a thin layer of an emissive oxide material responsive to incident radiation, thereby providing a plurality of radiation sensitive channels for the micro-channel plate detector.

  18. Gold plating on spectacle frames.

    Science.gov (United States)

    Kenny, I; Mitchell, J W; Walsh, G

    1997-05-01

    An investigation was carried out into the thickness and standard of application of the plating and lacquer coatings applied to three metal spectacle frames. All conform to BS 6625 (1991) for plating thickness, but there was considerable variation in regularity and porosity.

  19. Solar energy

    Science.gov (United States)

    Rapp, D.

    1981-01-01

    The book opens with a review of the patterns of energy use and resources in the United States, and an exploration of the potential of solar energy to supply some of this energy in the future. This is followed by background material on solar geometry, solar intensities, flat plate collectors, and economics. Detailed attention is then given to a variety of solar units and systems, including domestic hot water systems, space heating systems, solar-assisted heat pumps, intermediate temperature collectors, space heating/cooling systems, concentrating collectors for high temperatures, storage systems, and solar total energy systems. Finally, rights to solar access are discussed.

  20. Solar energy

    Science.gov (United States)

    Rapp, D.

    1981-01-01

    The book opens with a review of the patterns of energy use and resources in the United States, and an exploration of the potential of solar energy to supply some of this energy in the future. This is followed by background material on solar geometry, solar intensities, flat plate collectors, and economics. Detailed attention is then given to a variety of solar units and systems, including domestic hot water systems, space heating systems, solar-assisted heat pumps, intermediate temperature collectors, space heating/cooling systems, concentrating collectors for high temperatures, storage systems, and solar total energy systems. Finally, rights to solar access are discussed.