WorldWideScience

Sample records for plate mcp technologies

  1. Single ion counting with a MCP (microchannel plate) detector

    Energy Technology Data Exchange (ETDEWEB)

    Tawara, Hiroko; Sasaki, Shinichi; Miyajima, Mitsuhiro [National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan); Shibamura, Eido

    1996-07-01

    In this study, a single-ion-counting method using alpha-particle-impact ionization of Ar atoms is demonstrated and the preliminary {epsilon}{sub mcp} for Ar ions with incident energies of 3 to 4.7 keV is determined. The single-ion counting by the MCP is aimed to be performed under experimental conditions as follows: (1) A signal from the MCP is reasonably identified as incidence of single Ar-ion. (2) The counting rate of Ar ions is less than 1 s{sup -1}. (3) The incident Ar ions are not focused on a small part of an active area of the MCP, namely, {epsilon}{sub mcp} is determined with respect to the whole active area of the MCP. So far, any absolute detection efficiency has not been reported under these conditions. (J.P.N.)

  2. Characteristics and applications of advanced technology microchannel plates

    Science.gov (United States)

    Horton, Jerry R.; Tasker, G. William; Fijol, John J.

    1990-10-01

    A method for fabrication of novel thin-filrn continuous dynode electron multipliers is described. We have shown the feasibility of crucial manufacturing steps, including anisotropic dry etching of substrates into photolithographically-defined arrays of high-aspect-ratio channels, and the formation of thin-film continuous dynodes by chemical vapor deposition. We discuss potential performance and design advantages of this advanced technology microchannel plate (AT-MCP) over the conven tional reduced lead silicate glass inicrochannel plate (RLSG-'MCP) and implications for new applications.

  3. Image translational shifts in microchannel plate detectors due to the presence of MCP channel bias

    CERN Document Server

    Tremsin, A S; Siegmund, O H W

    2002-01-01

    A detailed study of possible image displacements in MCP detectors due to the presence of MCP pore bias is presented. We show that fluctuations of the rear accelerating field, characteristic to some MCP detector configurations, result in translational shifts of the entire image, which degrade the detector spatial resolution. It was experimentally observed that a 10% increase in the rear voltage of 400 V for a detector with 13 deg. -biased MCPs and 8.5 mm MCP-to-anode distance results in a 32 mu m shift of the image in the direction opposite to the pore bias. Increasing the voltage to 800 V induced a 200 mu m image displacement. No displacement was observed for a detector with a 0 deg. -biased output MCP. We also present a model for calculation of the charge footprint centroid in MCP detectors based on the output distribution function of the charge cloud. The results of our computer simulation of the image displacements prove to be in a very good agreement with the experimental data, thus providing the basis fo...

  4. Neutron Imager and Flux Monitor Based on Micro Channel Plates (MCP) in Electrostatic Mirror Configuration

    Science.gov (United States)

    Variale, V.

    In this paper, a new high transparency device based on MCP for the monitoring the flux and spatial profile of a neutron beam will be described. The assembly consists of a carbon foil with a 6Li deposit, placed in the beam, and a MCP equipped with a phosphor screen readout viewed by a CCD camera, placed outside the beam. Secondary emitted electrons (SEE) produced in the carbon foil by the alpha-particles and tritons from the 6Li+n reaction, are deflected to the MCP detector by means of an electrostatic mirror, suitably designed to preserve the spatial resolution. The conductive layer on the phosphor can be used for neutron counting, and to obtain time-of-flight information. A peculiar feature of this device is that the use of an electrostatic mirror minimizes the perturbation of the neutron beam, i.e. absorption and scattering. It can be used at existing time-of-flight (TOF) facilities, in particular at the n_TOF facility at CERN, for monitoring the flux and special profile of the neutron beam in the thermal and epithermal region. In this work, the device principle and design will be presented, together with the main features in terms of resolution and neutron detection efficiency.

  5. Development of a New Fast Shower Maximum Detector Based on Microchannel Plates Photomultipliers (MCP-PMT) as an Active Element

    Energy Technology Data Exchange (ETDEWEB)

    Ronzhin, A. [Fermilab; Los, S. [Fermilab; Ramberg, E. [Fermilab; Spiropulu, M. [Caltech; Apresyan, A. [Caltech; Xie, S. [Caltech; Kim, H. [Chicago U.; Zatserklyaniy, A. [UC, Santa Cruz

    2014-09-21

    One possibility to make a fast and radiation resistant shower maximum (SM) detector is to use a secondary emitter as an active element. We present below test beam results, obtained with different types of photodetectors based on microchannel plates (MCPs) as the secondary emitter. We performed the measurements at the Fermilab Test Beam Facility with 120GeV proton beam and 12GeV and 32GeV secondary beams. The goal of the measurement with 120GeV protons was to determine time resolution for minimum ionizing particles (MIPs). The SM time resolution we obtained for this new type of detector is at the level of 20-30ps. We estimate that a significant contribution to the detector response originates from secondary emission of the MCP. This work can be considered as the first step in building a new type of calorimeter based on this principle.

  6. Development of a New Fast Shower Maximum Detector Based on Microchannel Plates Photomultipliers (MCP-PMT) as an Active Element

    Energy Technology Data Exchange (ETDEWEB)

    Ronzhin, A. [Fermilab; Los, S. [Fermilab; Ramberg, E. [Fermilab; Spiropulu, M. [Caltech; Apresyan, A. [Caltech; Xie, S. [Caltech; Kim, H. [Chicago U.; Zatserklyaniy, A. [UC, Santa Cruz

    2014-09-21

    One possibility to make a fast and radiation resistant shower maximum (SM) detector is to use a secondary emitter as an active element. We present below test beam results, obtained with different types of photodetectors based on microchannel plates (MCPs) as the secondary emitter. We performed the measurements at the Fermilab Test Beam Facility with 120GeV proton beam and 12GeV and 32GeV secondary beams. The goal of the measurement with 120GeV protons was to determine time resolution for minimum ionizing particles (MIPs). The SM time resolution we obtained for this new type of detector is at the level of 20-30ps. We estimate that a significant contribution to the detector response originates from secondary emission of the MCP. This work can be considered as the first step in building a new type of calorimeter based on this principle.

  7. Image Shutters: Gated Proximity-Focused Microchannel-Plate (MCP) Wafer Tubes Versus Gated Silicon Intensified Target (SIT) Vidicons

    Science.gov (United States)

    Yates, G. J.; King, N. S. P.; Jaramillo, S. A.; Ogle, J. W.; Noel, B. W.; Thayer, N. N.

    1983-03-01

    The imaging characteristics of two fast image shutters used for recording the spatial and temporal evolution of transient optical events in the nanosecond range have been studied. Emphasis is on the comparative performances of each shutter type under similar conditions. Response data, including gating speed, gain, dynamic range, shuttering efficiency, and resolution for 18 and 25-mm-diam proximity-focused microchannel-plate (MCP) intensifiers are com-pared with similar data for a prototype electrostatically-focused 25-mm-diam gated silicon-intensified-target (SIT) vidicon currently under development for Los Alamos National Laboratory. Several key parameters critical to optical gating speed have been varied in both tube types in order to determine the optimum performance attainable from each design. These include conductive substrate material and thickness used to reduce photocathode resistivity, spacing between gating electrodes to minimize interelectrode capacitance, the use of con-ductive grids on the photocathode substrate to permit rapid propagation of the electrical gate pulse to all areas of the photocathode, and different package geometries to provide a more effective interface with external biasing and gating circuitry. For comparable spatial resolution, most 18-mm-diam MCPs require gate times > 2.5 ns while the fastest SIT has demonstrated sub-nanosecond optical gates as short as r 400 ± 50 ps for full shuttering of the 25-mm-diam input window.

  8. Image shutters: Gated proximity-focused Microchannel Plate (MCP) wafer tubes versus gated Silicon Intensified Target (SIT) vidicons

    Science.gov (United States)

    Yates, G. J.; King, N. S. P.; Jaramillo, S. A.; Ogle, J. W.; Noel, B. W.; Thayer, N. N.

    Response data, including gating speed, gain, dynamic range, shuttering efficiency, and resolution for 18- and 25-mm-diam proximity-focused microchannel-plate (MCP) intensifiers are compared with similar data for a prototype electrostatically-focused 25-mm-diam gated silicon-intensified-target (SIT) vidicon. Conductive substrate material and thickness used to reduce photocathode resistivity, spacing between gating electrodes to minimize inter-electrode capacitance, the use of conductive grids on the photocathode substrate to permit rapid propagation of the electrical gate pulse to all areas of the photocathode, and different package geometries to provide a more effective interface with external biasing and gating circuitry were varied in both tube types to determine optimal performance from each design. For comparable spatial resolution, most 18-mm-diam MCPs require gate times 2.5 ns while the fastest SIT has demonstrated sub-nanosecond optical gates as short as approximately 400 + or - 50 ps for full shuttering of the 25-mm-diam input window.

  9. Status of the Timepix MCP-HPD development

    CERN Document Server

    Tick, T; Michel, T; O'Shea, V; Plackett, R; Pospisil, S; Vallerga, J; Visser, J

    2010-01-01

    This paper describes the design of a high-speed, single-photon sensitive, Hybrid Photon Detector (HPD). The detector consists of a vacuum tube, containing a Micro Channel Plate (MCP) and 4 CMOS pixel readout chips, sealed with a transparent optical input window with a photocathode. The design described here utilizes currently available technologies, specifically the Timepix readout chips and the Photonis Planacon MCP-PMT vacuum tubes. The aim of the project is to demonstrate the feasibility of a 4-side buttable square MCP-HPD with high packing fraction sensitive area. Presented here is the mechanical and thermal design of the prototype detector

  10. Low noise and conductively cooled microchannel plates

    Science.gov (United States)

    Feller, W. B.

    1990-01-01

    Microchannel plate (MCP) dynamic range has recently been enhanced for both very low and very high input flux conditions. Improvements in MCP manufacturing technology reported earlier have led to MCPs with substantially reduced radioisotope levels, giving dramatically lower internal background-counting rates. An update is given on the Galileo low noise MCP. Also, new results in increasing the MCP linear counting range for high input flux densities are presented. By bonding the active face of a very low resistance MCP (less than 1 megaohm) to a substrate providing a conductive path for heat transport, the bias current limit (hence, MCP output count rate limit) can be increased up to two orders of magnitude. Normal pulse-counting MCP operation was observed at bias currents of several mA when a curved-channel MCP (80:1) was bonded to a ceramic multianode substrate; the MCP temperature rise above ambient was less than 40 C.

  11. Compact MCP assemblies for mass spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Matsuura, S. [Hamamatsu Photonics K.K., Shizuoka (Japan). Electron Tube Div.; Umebayashi, S. [Hamamatsu Photonics K.K., Shizuoka (Japan). Electron Tube Div.; Kusuyama, Y. [Hamamatsu Photonics K.K., Shizuoka (Japan). Electron Tube Div.; Natsume, Y. [Hamamatsu Photonics K.K., Shizuoka (Japan). Electron Tube Div.; Oba, K. [Hamamatsu Photonics K.K., Shizuoka (Japan). Electron Tube Div.

    1995-09-01

    We have developed compact microchannel plate (MCP) assemblies which have a high gain, good pulse height resolution and a fast response for MS applications. In this paper, these new assemblies are described referring to their structures, functions and characteristics. (orig.).

  12. Lifetime of MCP-PMTs

    Science.gov (United States)

    Lehmann, A.; Britting, A.; Eyrich, W.; Pfaffinger, M.; Uhlig, F.; Belias, A.; Dzhygadlo, R.; Gerhardt, A.; Götzen, K.; Kalicy, G.; Krebs, M.; Lehmann, D.; Nerling, F.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwarz, C.; Schwiening, J.; Traxler, M.; Zühlsdorf, M.; Düren, M.; Etzelmüller, E.; Föhl, K.; Hayrapetyan, A.; Kröck, B.; Merle, O.; Rieke, J.; Schmidt, M.; Cowie, E.; Keri, T.; Achenbach, P.; Cardinali, M.; Hoek, M.; Lauth, W.; Schlimme, S.; Sfienti, C.; Thiel, M.

    2016-05-01

    The hadron identification in the PANDA experiment at FAIR will be done with DIRC detectors. Because of design and space reasons the sensors of the DIRCs have to be placed inside the strong magnetic field of the solenoid. As the favored photon sensors microchannel-plate photomultipliers (MCP-PMTs) were identified. However, these devices showed serious aging problems until very recently, which manifest themselves by a fast degrading quantum efficiency (QE) of the photo cathode (PC). This is mainly due to feedback ions from the residual gas. In this paper we discuss the recently accomplished huge improvements in the lifetime of MCP-PMTs. With innovative countermeasures applied to the MCP-PMTs in the attempt to reduce the aging effects the manufacturers were able to increase the lifetime of MCP-PMT prototypes by almost two orders of magnitude compared to the former commercially available devices. Our group has studied the aging of MCP-PMTs for more than four years by simultaneously illuminating different types of lifetime-enhanced MCP-PMTs at the same photon rate. Gain, dark count rate, and QE as a function of the wavelength and the PC surface were measured in regular time intervals and studied in dependence of the integrated anode charge. We observe that MCP-PMTs treated with an atomic layer deposition (ALD) technique are by far the best devices available now. A lifetime of up to 10 C/cm2 integrated anode charge was reached with these sensors. This is sufficient for both PANDA DIRCs.

  13. Manufacturing Technology and Application Trends of Titanium Clad Steel Plates

    Institute of Scientific and Technical Information of China (English)

    Hang SU; Xiao-bing LUO; Feng CHAI; Jun-chang SHEN; Xin-jun SUN; Feng LU

    2015-01-01

    Some of the major manufacturing processes and corresponding mechanical properties of titanium clad steel plates were analyzed, and the consequences of research, manufacturing, and application of titanium clad steel plates in both markets of China and overseas were also summarized. As an economical and environmentally friendly technology, the roll bonding process is ex-pected to become the next-generation mainstream process for the manufacturing of titanium clad steel plate. Some of the crucial and most important technical problems of this particular process, including vacuum sealing technology, surface treatment process technology, application of a transition layer, and rolling process, were discussed along with the advantageous mechanical properties and life-cycle economy of these plates processed by this technology. Finally, the market needs, application trends, and requirements of titanium clad steel plate were also considered from industries of petrochemical, shipbuilding, marine, and electric power.

  14. Is plate tectonics needed to evolve technological species on exoplanets?

    Directory of Open Access Journals (Sweden)

    Robert J. Stern

    2016-07-01

    Full Text Available As we continue searching for exoplanets, we wonder if life and technological species capable of communicating with us exists on any of them. As geoscientists, we can also wonder how important is the presence or absence of plate tectonics for the evolution of technological species. This essay considers this question, focusing on tectonically active rocky (silicate planets, like Earth, Venus, and Mars. The development of technological species on Earth provides key insights for understanding evolution on exoplanets, including the likely role that plate tectonics may play. An Earth-sized silicate planet is likely to experience several tectonic styles over its lifetime, as it cools and its lithosphere thickens, strengthens, and becomes denser. These include magma ocean, various styles of stagnant lid, and perhaps plate tectonics. Abundant liquid water favors both life and plate tectonics. Ocean is required for early evolution of diverse single-celled organisms, then colonies of cells which specialized further to form guts, appendages, and sensory organisms up to the complexity of fish (central nervous system, appendages, eyes. Large expanses of dry land also begin in the ocean, today produced above subduction zones in juvenile arcs and by their coalescence to form continents, although it is not clear that plate tectonics was required to create continental crust on Earth. Dry land of continents is required for further evolution of technological species, where modification of appendages for grasping and manipulating, and improvement of eyes and central nervous system could be perfected. These bioassets allowed intelligent creatures to examine the night sky and wonder, the beginning of abstract thinking, including religion and science. Technology arises from the exigencies of daily living such as tool-making, agriculture, clothing, and weapons, but the pace of innovation accelerates once it is allied with science. Finally, the importance of plate

  15. Tremendously increased lifetime of MCP-PMTs

    Science.gov (United States)

    Lehmann, A.; Britting, A.; Eyrich, W.; Pfaffinger, M.; Uhlig, F.; Belias, A.; Dzhygadlo, R.; Gerhardt, A.; Götzen, K.; Kalicy, G.; Krebs, M.; Lehmann, D.; Nerling, F.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwarz, C.; Schwiening, J.; Traxler, M.; Zühlsdorf, M.; Düren, M.; Etzelmüller, E.; Föhl, K.; Hayrapetyan, A.; Kröck, B.; Merle, O.; Rieke, J.; Schmidt, M.; Cowie, E.; Keri, T.; Achenbach, P.; Cardinali, M.; Hoek, M.; Lauth, W.; Schlimme, S.; Sfienti, C.; Thiel, M.

    2017-02-01

    Microchannel plate (MCP) PMTs are very attractive photon sensors for low light level applications in strong magnetic fields. However, until recently the main drawback of MCP-PMTs was their aging behavior which manifests itself in a limited lifetime due to a rapidly decreasing quantum efficiency (QE) of the photo cathode (PC) as the integrated anode charge (IAC) increases. In the latest models of PHOTONIS, Hamamatsu, and BINP novel techniques are applied to avoid these aging effects which are supposed to be mainly caused by feedback ion impinging on the PC and damaging it. For more than four years we are running a long-term aging test with new lifetime-enhanced MCP-PMT models by simultaneously illuminating various PMTs with roughly the same photon rate. This allows a fair comparison of the lifetime of all investigated MCP-PMTs and will give some insight into the best techniques to be applied for a lifetime enhancement. In this paper the results of comprehensive aging tests will be discussed. Gain, dark count rate and QE were investigated for their dependence on the IAC. The QE was measured spectrally resolved and as a function of the position across the PC to identify regions where the damage develops first. For the best performing tubes the lifetime improvement compared to former MCP-PMTs is a factor of ∼ 50 based on an IAC of meanwhile > 10 C /cm2. This breakthrough in the lifetime of MCP-PMTs was achieved by coating the MCP pores with an atomic layer deposition (ALD) technique.

  16. Functionalized Nano-Film Microchannel Plate: A Single High Aspect Ratio Device for High Resolution, Low Noise Astronomical Imaging Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation is to apply proven nano-film technology to enable Microchannel plate (MCP) devices to be manufactured on a range of insulating substrates and...

  17. Functionalized Nano-Film Microchannel Plate: A Single High Aspect Ratio Device for High Resolution, Low Noise Astronomical Imaging Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Atomic layer deposited functional nano-film technology is used to manufacture Microchannel plate (MCP) devices capable of high gain / low ion feedback operation, on...

  18. Study on Technology and Properties of Brush Plating Coatings

    Institute of Scientific and Technical Information of China (English)

    DI Ping

    2004-01-01

    A new brush plating process with a soluble anode of nickel was introduced. TDY112 brush plating solution was used on the No.20 carbon steel substrate. It has the higher deposit velocity, better properties and lower cost. Scanning electronic microscopy(SEM), optical microscope, microhardness test and wear test were adopted to detect the surface quality and the properties of the coating, such as micrograph, microstructure, micro-hardness wear resistance and adherence between the coating and the substrate. The experimental results showed that the suitable technological parameters to be used, the coatings had better the surface quality, higher hardness and wear resistance.

  19. Cr plating technology for preventing Fuel Cladding Chemical Interaction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jun Hwan; Ryu, Ho Jin; Jee, Seung Hyun; Cheon, Jin Sik; Lee, Byoung Oon; Lee, Chan Bock; Yang, Seong Woo [KAERI, Daejeon (Korea, Republic of)

    2010-11-15

    The objectives of the report are to analyze chrome electroplating technology in order to apply in the field of diffusion barrier to suppress Fuel-Cladding Chemical Interaction (FCCI). This report consists of the principle of the chrome electroplating, plating parameter and possibility of the barrier application. Chrome plating has been considered as one of the probable candidates in the field of barrier tube because of its simpleness, superior FCCI resistance, and effective coating performance at relatively low cost. However, cracks can be generate at the surface of the coating surface which reduces the coating performance. To minimize such a crack, controlling plating parameter like bath composition and bath temperature, current profile, and post-heat treatment has been reviewed. Concept for the application at the inner surface of the cladding has been also described. Based on the technology that suggested at the present report, optimizing plating parameter will be carried out. After the performance test like diffusion couple test of the metallic fuel, final barrier condition will be concluded and the fabrication of the prototype barrier tube will be conducted in the near future

  20. Green Plate-making Technology Based on Nanomaterials

    Institute of Scientific and Technical Information of China (English)

    SONG Yanlin

    2011-01-01

    @@ Movable type printing technology is one of the four great inventions of ancient China which played a significant role in passing down the history and civilization of human society.Today, with economic development and people's diverse needs for presswork, printing has penetrated into all spheres of life, and the printing industry has become one of the industries that have important impacts on China's national economy.Since China is now the third largest printing market in the world, the rapid development of this huge market calls for digital plate-making technologies for the sake of environmental protection.

  1. Two micron pore size MCP-based image intensifiers

    Science.gov (United States)

    Glesener, John; Estrera, Joseph

    2010-02-01

    Image intensifiers (I2) have many advantages as detectors. They offer single photon sensitivity in an imaging format, they're light in weight and analog I2 systems can operate for hours on a single AA battery. Their light output is such as to exploit the peak in color sensitivity of the human eye. Until recent developments in CMOS sensors, they also were one of the highest resolution sensors available. The closest all solid state solution, the Texas Instruments Impactron chip, comes in a 1 megapixel format. Depending on the level of integration, an Impactron based system can consume 20 to 40 watts in a system configuration. In further investing in I2 technology, L-3 EOS determined that increasing I2 resolution merited a high priority. Increased I2 resolution offers the system user two desirable options: 1) increased detection and identification ranges while maintaining field-of-view (FOV) or 2) increasing FOV while maintaining the original system resolution. One of the areas where an investment in resolution is being made is in the microchannel plate (MCP). Incorporation of a 2 micron MCP into an image tube has the potential of increasing the system resolution of currently fielded systems. Both inverting and non-inverting configurations are being evaluated. Inverting tubes are being characterized in night vision goggle (NVG) and sights. The non-inverting 2 micron tube is being characterized for high resolution I2CMOS camera applications. Preliminary measurements show an increase in the MTF over a standard 5 micron pore size, 6 micron pitch plate. Current results will be presented.

  2. Carbon black dispersion pre-plating technology for printed wire board manufacturing. Final technology evaluation report

    Energy Technology Data Exchange (ETDEWEB)

    Folsom, D.W.; Gavaskar, A.R.; Jones, J.A.; Olfenbuttel, R.F.

    1993-10-01

    The project compared chemical use, waste generation, cost, and product quality between electroless copper and carbon-black-based preplating technologies at the printed wire board (PWB) manufacturing facility of McCurdy Circuits in Orange, CA. The carbon-black based preplating technology evaluated is used as an alternative process for electroless copper (EC) plating of through-holes before electrolytic copper plating. The specific process used at McCurdy is the BlackHole (BH) technology process, which uses a dispersion of carbon black in an aqueous solution to provide a conductive surface for subsequent electrolytic copper plating. The carbon-black dispersion technology provided effective waste reduction and long-term cost savings. The economic analysis determined that the new process was cost efficient because chemical use was reduced and the process proved more efficient; the payback period was less than 4 yrs.

  3. Single electron counting using a dual MCP assembly

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yuzhen [School of Physics, Nanjing University, Nanjing 210093 (China); Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); State Key Laboratory of Particle Detection and Electronics, Beijing 100049 (China); Liu, Shulin, E-mail: liusl@ihep.ac.cn [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); State Key Laboratory of Particle Detection and Electronics, Beijing 100049 (China); Zhao, Tianchi, E-mail: tianchi@u.washington.edu [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); State Key Laboratory of Particle Detection and Electronics, Beijing 100049 (China); Department of Physics, University of Washington, Seattle, WA 98195 (United States); Yan, Baojun; Wang, Peiliang [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); State Key Laboratory of Particle Detection and Electronics, Beijing 100049 (China); Yu, Yang [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); State Key Laboratory of Particle Detection and Electronics, Beijing 100049 (China); School of Science, Xi’an University of Technology, Xi’an 710048 (China); Lei, Xiangcui [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); State Key Laboratory of Particle Detection and Electronics, Beijing 100049 (China); Yang, Luping [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); State Key Laboratory of Particle Detection and Electronics, Beijing 100049 (China); School of Physics and Electronics, Henan University, Kaifeng 475004 (China); Wen, Kaile [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); State Key Laboratory of Particle Detection and Electronics, Beijing 100049 (China); Qi, Ming [School of Physics, Nanjing University, Nanjing 210093 (China); and others

    2016-09-11

    The gain, pulse height resolution and peak-to-valley ratio of single electrons detected by using a Chevron configured Microchannel Plate (MCP) assembly are studied. The two MCPs are separated by a 280 µm gap and are biased by four electrodes. The purpose of the study is to determine the optimum bias voltage arrangements for single electron counting. By comparing the results of various bias voltage combinations, we conclude that good performance for the electron counting can be achieved by operating the MCP assembly in saturation mode. In addition, by applying a small reverse bias voltage across the gap while adjusting the bias voltages of the MCPs, optimum performance of electron counting can be obtained. - Highlights: • Dual MCPs assembly with four electrodes using different voltage combinations has been investigated for single electron counting. • Both the MCP voltages and the gap voltage can affect the gain, pulse height resolution and P/V ratio. • A high gain of the first stage MCP, a saturation mode of the second stage MCP and an appropriately reverse gap voltage can improve the resolution greatly. • The optimum voltage arrangements is significant for the design of MCP detectors in single electron counting applications.

  4. Computer-to-plate Technology: Violet or Thermo?

    Directory of Open Access Journals (Sweden)

    Michael Mittelhaus

    2004-12-01

    Full Text Available Up to now CtP has been a technology for medium-sized and large companies and their printing presses, and thus predominantly in the 70 x 100 cm format and larger. The CtP technology is and remains divided up between violet and thermo, with the advantages and drawbacks of both imaging systems in a counterbalance. Due to the broad penetration of CtP in many markets, practical questions have now come to the fore, including those of continuous process control and quality assurance; providers and specialist forums on these topics will also hold centre stage at drupa. This applies equally to frequency-modulated screening processes, which are today well known and are viewed as a means for ensuring a competitive edge. The CtP technology is now broader and more diverse than ever, and drupa 2004 will clarify which technology and which imagers best allow economical digital plate production for formats up to 50 x 70 cm.

  5. Resolution changes of MCP-PMTs in magnetic fields

    Science.gov (United States)

    Rieke, J.; Belias, A.; Dzhygadlo, R.; Gerhardt, A.; Götzen, K.; Kalicy, G.; Krebs, M.; Lehmann, D.; Nerling, F.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwarz, C.; Schwiening, J.; Traxler, M.; Zühlsdorf, M.; Britting, A.; Eyrich, W.; Lehmann, A.; Pfaffinger, M.; Uhlig, F.; Düren, M.; Etzelmüller, E.; Föhl, K.; Hayrapetyan, A.; Kröck, B.; Merle, O.; Rieke, J.; Schmidt, M.; Cowie, E.; Keri, T.; Achenbach, P.; Cardinali, M.; Hoek, M.; Lauth, W.; Schlimme, S.; Sfienti, C.; Thiel, M.

    2016-05-01

    Micro-channel plate photomultiplier tubes (MCP-PMTs) are chosen in many applications that have to cope with strong magnetic fields. The DIRC detectors of the PANDA experiment plan to employ them as they show excellent timing characteristics, radiation hardness, relatively low dark count rates and sufficient lifetime. This article mainly focuses on the performance of the position reconstruction of detected photons. Two different MCP-PMTs with segmented anode geometries have been tested in magnetic fields of different strengths. The variation of their performance has been studied. The measurements show improved position resolution and image shifts with increasing magnetic field strength.

  6. Automatic brush-plating technology for component remanufacturing

    Institute of Scientific and Technical Information of China (English)

    WU Bin; XU Bin-shi; JING Xue-dong; LIU Cun-long; ZHANG Bin

    2005-01-01

    An automatic brush-plating system was developed for component remanufacturing. With this system, Ni/nano-alumina composite coatings from an electrolyte containing 20 g/L nano-alumina particles were prepared.Microstructure, surface morphology, microhardness and wear resistance of automatically plated coatings and manu ally plated coatings were investigated comparatively. The results show that the automatically plated coatings are relatively dense and uniform and have lower friction coefficient of 0. 089 under lubricant condition, when compared with manually plated coatings with friction coefficient of 0. 14.

  7. Highly curved microchannel plates

    Science.gov (United States)

    Siegmund, O. H. W.; Cully, S.; Warren, J.; Gaines, G. A.; Priedhorsky, W.; Bloch, J.

    1990-01-01

    Several spherically curved microchannel plate (MCP) stack configurations were studied as part of an ongoing astrophysical detector development program, and as part of the development of the ALEXIS satellite payload. MCP pairs with surface radii of curvature as small as 7 cm, and diameters up to 46 mm have been evaluated. The experiments show that the gain (greater than 1.5 x 10 exp 7) and background characteristics (about 0.5 events/sq cm per sec) of highly curved MCP stacks are in general equivalent to the performance achieved with flat MCP stacks of similar configuration. However, gain variations across the curved MCP's due to variations in the channel length to diameter ratio are observed. The overall pulse height distribution of a highly curved surface MCP stack (greater than 50 percent FWHM) is thus broader than its flat counterpart (less than 30 percent). Preconditioning of curved MCP stacks gives comparable results to flat MCP stacks, but it also decreases the overall gain variations. Flat fields of curved MCP stacks have the same general characteristics as flat MCP stacks.

  8. MCP-based detector some results and perspectives

    CERN Document Server

    Patarakin, O O; Strepetov, A N; Turbin, E V; Sinitsin, V I; Kartamushev, A A

    1997-01-01

    The timing resolution of photomultiplier tubes (PMT) based on shevron-type microchannel plates (MCP) has been studied inmagnetic fields. The same timingresolution with and without a longitudinal magnetic field up to 2.0 kGwas obtained as = 85 ± 2 ps. It is shown that an increase of timing resolution in this magnetic field does not exceed25 ps (upper limit). The timing resolution of = 31 ± 2 pswas obtained for narrow (10resolution) amplitude spectrumfrom Corone discharge. The counting rate of MCP-based detector was studied in function of the direction of the magnetic field.The spatial and timing resolution for the MCP-based PMT were obtained using laser pulses as well. With laser pulses of 0.3 ns a timing resolution of ≅ 450 ps was obtained. Taking into account the amplitude correction narrows to 140 ps. Using 100 fs-laser with the standard constant fractiondiscriminator gives a timing resolution from 20 to 40 ps depending on the read-out MCP region.The perspectives of using...

  9. Saturation and Dynamic Range of Microchannel Plate-Based X-Ray Imagers

    Energy Technology Data Exchange (ETDEWEB)

    ,

    2012-05-04

    This paper describes recent advances in Monte Carlo simulations of microchannel plate (MCP)–based x-ray detectors, a continuation of ongoing work in this area. A Monte Carlo simulation model has been developed over the past several years by National Security Technologies, LLC (NSTec). The model simulates the secondary electron emission process in an MCP pore and includes the effects of gain saturation. In this work we focus on MCP gain saturation and dynamic range. We have performed modeling and experimental characterizations of L/D = 46, 10-micron diameter, MCP-based detectors. The detectors are typically operated by applying a subnanosecond voltage pulse, which gates the detector on. Agreement between the simulations and experiment is very good for a variety of voltage pulse waveforms ranging in width from 150 to 300 ps. The results indicate that such an MCP begins to show nonlinear gain around 5 × 10^4 electrons per pore and hard saturation around 105 electrons per pore. The simulations show a difference in MCP sensitivity vs voltage for high flux of photons producing large numbers of photoelectrons on a subpicosecond timescale. Simulations and experiments both indicate an MCP dynamic range of 1 to 10,000, and the dynamic range depends on how the voltage is applied.

  10. Thermal dependence of electrical characteristics of micromachined silica microchannel plates

    Science.gov (United States)

    Tremsin, Anton S.; Vallerga, John V.; Siegmund, Oswald H. W.; Beetz, Charles P.; Boerstler, Robert W.

    2004-04-01

    Micromachined silica microchannel plates (MCPs) under development have a number of advantages over standard glass MCPs and open completely new possibilities in detector technologies. In this article we present the results of our studies on the thermal properties of silica microchannel plates (sMCPs). Similar to standard glass microchanel plates the resistance of silica MCPs was measured to change exponentially with temperature with a negative thermal coefficient of -0.036 per °C, somewhat larger than that of standard glass MCPs. The resistance also decreases linearly with the applied voltage, with the voltage coefficient of -3.1×10-4 V-1. With the knowledge of these two coefficients, our thermal model allows the calculation of the maximum voltage, which can be applied to a given MCP without inducing a thermal runaway. A typical 25 mm diam, 240 μm thick sMCP with 6 μm pores has to have the resistance larger than ˜30 MΩ to operate safely at voltages up to 800 V. With this model we can also calculate the time required for a given silica MCP to reach the point of thermal equilibrium after a voltage increase. We hope that the ongoing efforts on a proper modification of the sMCP semiconducting layer will lead to the production of new MCPs with a small negative or even a positive thermal coefficient, reducing the possibility of thermal runaways of low-resistance MCPs required for high count rate applications.

  11. PLATE

    DEFF Research Database (Denmark)

    Kling, Joyce; Hjulmand, Lise-Lotte

    2008-01-01

    ’s level of English is sufficient for the increasing number of courses offered in English each semester. This paper addresses these concerns and describes a pilot project initiated in 2003 at CBS to gauge the overall English language proficiency of those teaching content courses in English. Through......Copenhagen Business School (CBS) finds itself needing to address the issue of English-medium instruction for its increasing number of foreign exchange and full degree students. With internationalisation as a main pillar of the institution’s agenda, there are concerns whether the teaching faculty...... the Project in Language Assessment for Teaching in English (PLATE) language professionals from CBS’s Language Center observe teachers and provide feedback using evaluation criteria from the Common European Framework for Reference (CEFR) supplemented by some additional criteria which take the LSP nature...

  12. PLATE

    DEFF Research Database (Denmark)

    Kling, Joyce; Hjulmand, Lise-Lotte

    2008-01-01

    Copenhagen Business School (CBS) finds itself needing to address the issue of English-medium instruction for its increasing number of foreign exchange and full degree students. With internationalisation as a main pillar of the institution’s agenda, there are concerns whether the teaching faculty......’s level of English is sufficient for the increasing number of courses offered in English each semester. This paper addresses these concerns and describes a pilot project initiated in 2003 at CBS to gauge the overall English language proficiency of those teaching content courses in English. Through...... the Project in Language Assessment for Teaching in English (PLATE) language professionals from CBS’s Language Center observe teachers and provide feedback using evaluation criteria from the Common European Framework for Reference (CEFR) supplemented by some additional criteria which take the LSP nature...

  13. Development of the nanotiter plate for use in antibody and cell array technologies

    Science.gov (United States)

    Ramdutt, Devin; Lui, Rodney; Davies, Kerrie; Boswell, Rod W.; dos Remedios, Cristobal G.; Charles, Christine; Bilek, Marcela M.; McKenzie, David R.

    2005-02-01

    The design and fabrication of biomedical tools using techniques common in microelectronics is becoming established procedure. In our research, we use gaseous plasma dry etching to form microstructures on silicon wafers. These are intended for use in capturing and binding antibodies and live cells in an array to be used in High Throughput Screening (HTS) and High Content Screening (HCS) of new pharmaceuticals. We call this new arraying plate the "Nanotiter" plate. The benefit of our design (100 x 100 wells in a 25 x 25 mm array) over current 96-, 384- and 1056-well microtiter plates are that the number of samples (wells) that can be tested in one plate scan can be substantially increased, the wells can be rapidly and effectively washed, and the well surfaces can be modified to modulate ligand binding. Simple crowding of wells on a plate can result in cross contamination of samples in adjacent wells during the washing. Furthermore, motile cells may migrate between the wells. 1056 microtiter plates currently cannot be washed, and washing 384 plates is problematic. Our design incorporates plasma-deposited polymers that functionally bind antibodies (or other proteins) in but not between wells. Furthermore, the wells can be shaped to minimize cell migration. Inverting the plate on a wash solution allows unbound cells to simply fall away under gravity thus minimising the contamination of adjacent wells. Thus, our Nanotiter plate represents a substantial improvement over existing technology.

  14. Multichip on Aluminum Metal Plate Technology for High Power LED Packaging

    Institute of Scientific and Technical Information of China (English)

    Choong-mo NAM; Mi-hee JI

    2010-01-01

    Multichip on Aluminum Metal Plate(MOAMP) technology with simple structure and low thermal resistance is developed for effective heat removal of Light Emitting Diode(LED) p-n junction and LED lighting module to have high reliability. The thermal resistance of LED modules was numerical and experimental. Thermal resistance from the junction to aluminum metal plate, considering input power of LED module using MOAMP technology, is 3.02 K/W, 3.23 K/W for the measured and calculated, respectively. We expect that the reported MOAMP technology with low thermal resistance will be a promising solution for high power LED lighting modules.

  15. Sinorhizobium meliloti chemoreceptor McpU mediates chemotaxis toward host plant exudates through direct proline sensing.

    Science.gov (United States)

    Webb, Benjamin A; Hildreth, Sherry; Helm, Richard F; Scharf, Birgit E

    2014-06-01

    Bacterial chemotaxis is an important attribute that aids in establishing symbiosis between rhizobia and their legume hosts. Plant roots and seeds exude a spectrum of molecules into the soil to attract their bacterial symbionts. The alfalfa symbiont Sinorhizobium meliloti possesses eight chemoreceptors to sense its environment and mediate chemotaxis toward its host. The methyl accepting chemotaxis protein McpU is one of the more abundant S. meliloti chemoreceptors and an important sensor for the potent attractant proline. We established a dominant role of McpU in sensing molecules exuded by alfalfa seeds. Mass spectrometry analysis determined that a single germinating seed exudes 3.72 nmol of proline, producing a millimolar concentration near the seed surface which can be detected by the chemosensory system of S. meliloti. Complementation analysis of the mcpU deletion strain verified McpU as the key proline sensor. A structure-based homology search identified tandem Cache (calcium channels and chemotaxis receptors) domains in the periplasmic region of McpU. Conserved residues Asp-155 and Asp-182 of the N-terminal Cache domain were determined to be important for proline sensing by evaluating mutant strains in capillary and swim plate assays. Differential scanning fluorimetry revealed interaction of the isolated periplasmic region of McpU (McpU40-284) with proline and the importance of Asp-182 in this interaction. Using isothermal titration calorimetry, we determined that proline binds with a Kd (dissociation constant) of 104 μM to McpU40-284, while binding was abolished when Asp-182 was substituted by Glu. Our results show that McpU is mediating chemotaxis toward host plants by direct proline sensing.

  16. Phase plate technology for laser marking of magnetic discs

    Science.gov (United States)

    Neuman, B.; Honig, J.; Hackel, L.; Dane, C.B.; Dixit, S.

    1998-10-27

    An advanced design for a phase plate enables the distribution of spots in arbitrarily shaped patterns with very high uniformity and with a continuously or near-continuously varying phase pattern. A continuous phase pattern eliminates large phase jumps typically expected in a grating that provides arbitrary shapes. Large phase jumps increase scattered light outside of the desired pattern, reduce efficiency and can make the grating difficult to manufacture. When manufacturing capabilities preclude producing a fully continuous grating, the present design can be easily adapted to minimize manufacturing errors and maintain high efficiencies. This continuous grating is significantly more efficient than previously described Dammann gratings, offers much more flexibility in generating spot patterns and is easier to manufacture and replicate than a multi-level phase grating. 3 figs.

  17. Computer-to-plate Technology: Violet or Thermo?

    OpenAIRE

    Michael Mittelhaus

    2004-01-01

    Up to now CtP has been a technology for medium-sized and large companies and their printing presses, and thus predominantly in the 70 x 100 cm format and larger. The CtP technology is and remains divided up between violet and thermo, with the advantages and drawbacks of both imaging systems in a counterbalance. Due to the broad penetration of CtP in many markets, practical questions have now come to the fore, including those of continuous process control and quality assurance; providers and s...

  18. Firmeza de pêssegos 'diamante' tratados com 1-MCP Firmness of peach 'diamante' treated with 1-MCP

    Directory of Open Access Journals (Sweden)

    Fernanda Emanuele da Rocha Oliveira

    2005-12-01

    Full Text Available No Brasil, o consumo de pêssegos in natura vem aumentando a cada ano. No entanto, durante o transporte, o período de armazenamento e a comercialização, as perdas são bastante significativas, havendo a necessidade de desenvolver tecnologias para manter a qualidade pós-colheita e prolongar a vida útil desses frutos. O composto 1-metilciclopropeno (1-MCP vem sendo usado com resultados positivos em diversos tipos de frutos, como goiaba, banana, maçã, entre outras. Neste trabalho, foi avaliado o tratamento com 1-MCP em pêssegos armazenados em condições ambientais para a manutenção da firmeza dos frutos. Os frutos da cv. Diamante foram provenientes do município de Nepomuceno-MG, colhidos no estádio de maturação 'de vez' e selecionados em função do tamanho, estádio de maturação e ausência de injúrias. Os frutos foram submetidos à imersão em hipoclorito de sódio a 1% para desinfecção e parte deles foi tratada com 1-MCP, na concentração aproximada de 625 nL/L, por 12 horas. Em seguida, os frutos foram armazenados por até 10 dias, em temperatura ambiente (22 ± 2°C e 77 ± 2% UR. Foram realizadas análises de firmeza da polpa, solubilização de pectinas e atividades de pectinametilesterase e poligalacturonase a cada 2 dias até o final do período de armazenamento. Os frutos tratados com 1-MCP apresentaram maior firmeza e menor solubilização de pectinas durante o período avaliado e também menor atividade de pectinametilesterase que os frutos-controle até o 6º dia de armazenamento, demonstrando que o 1-MCP foi eficiente em retardar o amaciamento dos frutos no período estudado.In Brazil, the consumption of in natura peaches has been increasing every year. However, during the transport, the storage period and the commercialization, the losses are quite significant, having the need to develop technologies to maintain postharvest quality and to prolong the useful life of those fruits. The compound 1-methylcyclopropene

  19. Development of a micro-heat exchanger with stacked plates using LTCC technology

    Directory of Open Access Journals (Sweden)

    E. Vásquez-Alvarez

    2010-09-01

    Full Text Available A green ceramic tape micro-heat exchanger was developed using Low Temperature Co-fired Ceramics technology (LTCC. The device was designed by using Computational Aided Design software and simulations were made using a Computational Fluid Dynamics package (COMSOL Multiphysics to evaluate the homogeneity of fluid distribution in the microchannels. Four geometries were proposed and simulated in two and three dimensions to show that geometric details directly affect the distribution of velocity in the micro-heat exchanger channels. The simulation results were quite useful for the design of the microfluidic device. The micro-heat exchanger was then constructed using the LTCC technology and is composed of five thermal exchange plates in cross-flow arrangement and two connecting plates, with all plates stacked to form a device with external dimensions of 26 x 26 x 6 mm³.

  20. A review of an attempt to create shatter cones with magnetic flyer plate technology

    Science.gov (United States)

    Linnerud, H. J.

    1981-01-01

    The feasibility of creating shatter cones in a controlled laboratory environment is discussed. Magnetic flyer plate technology, which generates high amplitude shock waves in test materials is discribed. Considerable sample shear and break up was observed, however, no shatter cones are found in the tested samples.

  1. An introduction to the IAAT ultraviolet MCP detector development

    Science.gov (United States)

    Hermanutz, S.; Barnstedt, J.; Diebold, S.; Elsener, H. R.; Kalkuhl, C.; Kappelmann, N.; Pfeifer, M.; Schanz, T.; Werner, K.

    2014-07-01

    Observations of ultraviolet light is the key to understand high temperature processes in the universe like hot plasma, accretion processes or illuminated protoplanetary discs around UV sources. Furthermore these observation contribute to major cosmological questions, like the distribution of baryonic matter or the formation of the milky way, as pointed out by Gomez de Castro et al.1 Driven by the idea to participate in the Russian World Space Observatory we started to develop a position sensitive micro channel plate detector (MCP) for spectroscopy in the range of 160nm to 300 nm. Although we are not part of this project we still build a MCP detector prototype. In this paper we will present the general design of the detector and mainly focus on the aspect of our photocathode, while the electronics will be explained in more detail in the paper Characterisation of low power readout electronics for a UV microchannel plate detector with cross-strip readout" (Paper number 9144-116) by Marc Pfeifer.

  2. Optimization of the electron collection efficiency of a large area MCP-PMT for the JUNO experiment

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Lin, E-mail: chenlin@opt.cn [State Key Laboratory of Transient Optics and Photonics, Xi’an Institute of Optics and Precision Mechanics (XIOPM), Chinese Academy of Sciences (CAS), Xi’an 710119 (China); Graduate School of Chinese Academy of Sciences (CAS), Beijing 100049 (China); Xi’an Jiaotong University, Xi’an 710049 (China); Tian, Jinshou [Graduate School of Chinese Academy of Sciences (CAS), Beijing 100049 (China); Liu, Chunliang [Xi’an Jiaotong University, Xi’an 710049 (China); Wang, Yifang; Zhao, Tianchi [Institute of High Energy Physics (IHEP) of CAS, Beijing 100049 (China); Liu, Hulin; Wei, Yonglin; Sai, Xiaofeng [Graduate School of Chinese Academy of Sciences (CAS), Beijing 100049 (China); Chen, Ping [State Key Laboratory of Transient Optics and Photonics, Xi’an Institute of Optics and Precision Mechanics (XIOPM), Chinese Academy of Sciences (CAS), Xi’an 710119 (China); Graduate School of Chinese Academy of Sciences (CAS), Beijing 100049 (China); Wang, Xing; Lu, Yu [Graduate School of Chinese Academy of Sciences (CAS), Beijing 100049 (China); Hui, Dandan; Guo, Lehui [State Key Laboratory of Transient Optics and Photonics, Xi’an Institute of Optics and Precision Mechanics (XIOPM), Chinese Academy of Sciences (CAS), Xi’an 710119 (China); Graduate School of Chinese Academy of Sciences (CAS), Beijing 100049 (China); Liu, Shulin; Qian, Sen; Xia, Jingkai; Yan, Baojun; Zhu, Na [Institute of High Energy Physics (IHEP) of CAS, Beijing 100049 (China); Sun, Jianning; Si, Shuguang [North Night Vision Technology (NNVT) CO., LTD, Nanjing 210110 (China); and others

    2016-08-11

    A novel large-area (20-inch) photomultiplier tube based on microchannel plate (MCP-PMTs) is proposed for the Jiangmen Underground Neutrino Observatory (JUNO) experiment. Its photoelectron collection efficiency C{sub e} is limited by the MCP open area fraction (A{sub open}). This efficiency is studied as a function of the angular (θ), energy (E) distributions of electrons in the input charge cloud and the potential difference (U) between the PMT photocathode and the MCP input surface, considering secondary electron emission from the MCP input electrode. In CST Studio Suite, Finite Integral Technique and Monte Carlo method are combined to investigate the dependence of C{sub e} on θ, E and U. Results predict that C{sub e} can exceed A{sub open}, and are applied to optimize the structure and operational parameters of the 20-inch MCP-PMT prototype. C{sub e} of the optimized MCP-PMT is expected to reach 81.2%. Finally, the reduction of the penetration depth of the MCP input electrode layer and the deposition of a high secondary electron yield material on the MCP are proposed to further optimize C{sub e}.

  3. Evaluation of a new phosphor plate technology for neonatal portable chest radiographs.

    Science.gov (United States)

    Cohen, Mervyn; Corea, Donald; Wanner, Matthew; Karmazyn, Boaz; Gunderman, Richard; Applegate, Kimberly; Jennings, Samuel G

    2011-02-01

    The aim of this study was to evaluate a new thick-needle phosphor plate for computed radiography. Two studies were performed. Patients acted as their own controls. In the first study, old powder and new needle phosphor plate technologies were compared. Twenty infants were identified who had undergone chest x-rays with both systems within 3 days of each other. Exposure factors were constant. In the second study, standard and reduced exposure techniques (tube current-time product reduced by 20%) using the needle phosphor technology were compared. Twenty babies who had been imaged with both standard and reduced exposures within 3 days of each other were evaluated. There was a significant preference for images obtained with the new needle phosphor technology compared with the older powder technology (P exposure, images were better with the new technology. Using the new plate technology, dose can be decreased by ≥20%. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  4. Improvements in Boron Plate Coating Technology for Higher Efficiency Neutron Detection and Coincidence Counting Error Reduction

    Energy Technology Data Exchange (ETDEWEB)

    Menlove, Howard Olsen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Henzlova, Daniela [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-08-25

    This informal report presents the measurement data and information to document the performance of the advanced Precision Data Technology, Inc. (PDT) sealed cell boron-10 plate neutron detector that makes use of the advanced coating materials and procedures. In 2015, PDT changed the boron coating materials and application procedures to significantly increase the efficiency of their basic corrugated plate detector performance. A prototype sealed cell unit was supplied to LANL for testing and comparison with prior detector cells. Also, LANL had reference detector slabs from the original neutron collar (UNCL) and the new Antech UNCL with the removable 3He tubes. The comparison data is presented in this report.

  5. Development of a flight qualified 100 x 100 mm MCP UV detector using advanced cross strip anodes and associated ASIC electronics

    Science.gov (United States)

    Vallerga, John; McPhate, Jason; Tremsin, Anton; Siegmund, Oswald; Raffanti, Rick; Cumming, Harley; Seljak, Andrej; Virta, Vihtori; Varner, Gary

    2016-07-01

    Photon counting microchannel plate (MCP) imagers have been the detector of choice for most UV astronomical missions over the last three decades (e.g. EUVE, FUSE, COS on Hubble etc.) and been mentioned for instruments on future large telescopes in space such as LUVOIR14. Using cross strip anodes, improvements in the MCP laboratory readout technology have resulted in better spatial resolution (x10), temporal resolution (x 1000) and output event rate (x100), all the while operating at lower gain (x10) resulting in lower high voltage requirements and longer MCP lifetimes. A crossed strip anode MCP readout starts with a set of orthogonal conducting strips (e.g. 80 x 80), typically spaced at a 635 micron pitch onto which charge clouds from MCP amplified events land. Each strip has its own charge sensitive amplifier that is sampled continuously by a dedicated analog to digital converter (ADC). All of the ADC digital output lines are fed into a field programmable gate array (FGPA) which can detect charge events landing on the strips, measure the peak amplitudes of those charge events and calculate their spatial centroid along with their time of arrival (X,Y,T) and pass this information to a downstream computer. Laboratory versions of these electronics have demonstrated < 20 microns FWHM spatial resolution, count rates on the order of 2 MHz, and temporal resolution of 1ns. In 2012 our group at U.C. Berkeley, along with our partners at the U. Hawaii, received a NASA Strategic Astrophysics Technology (SAT) grant to raise the TRL of a cross strip detector from 4 to 6 by replacing most of the 19" rack mounted, high powered electronics with application specific integrated circuits (ASICs) which will lower the power, mass, and volume requirements of the detector electronics. We were also tasked to design and fabricate a "standard" 50mm square active area MCP detector incorporating these electronics that can be environmentally qualified for flight (temperature, vacuum, vibration

  6. Impact of different environmental stimuli on the release of 1-MCP from boron-MCP complexes

    Science.gov (United States)

    In our previous report, boron derivatives of methylene cyclopropane complexes (B-MCP) were developed to stabilize the gaseous 1-MCP (1-methylcyclopropene), a commercial plant growth regulator, for eventual release in open crop fields when under humid conditions or in contact with water. To meet the ...

  7. Development of Noncontact Imaging Technology for the Detection of Internal Defects of a Nuclear Fuel Plate

    Energy Technology Data Exchange (ETDEWEB)

    Park, S. K.; Baik, S. H.; Lee, Y. S.; Cheong, Y. M.

    2012-01-15

    The object of the research is to develop a new imaging inspection technology for the quality testing of plate-type nuclear fuel whose demanding is currently increasing in nuclear research reactors. A new noncontact imaging inspection technique is developed for the detection of internal defects in plate-type nuclear fuel. To develop the imaging inspection technique, a hardware system based on active optical interference is configured. An operating software for the developed nondestructive inspection system is developed after designing an advanced signal processing algorithm to improve the detection capability of the system. The developed system is optimized through experiments and optimal heating condition is studied. The performance of a lock-in thermography is also evaluated to see the possibility of the plate-type nuclear fuel application.

  8. [Characterization of Wood Surface Treated with Electroless Copper Plating by Near Infrared Spectroscopy Technology].

    Science.gov (United States)

    Qin, Jing; Zhang, Mao-mao; Zhao, Guang-jie; Yang, Zhong

    2015-05-01

    Wood electromagnetic shielding material, which was made by treating wood with electroless plating, not only keep the superior characteristics of wood, but also improve the conductivity, thermal conductivity and electromagnetic shielding properties of wood. The emergence of this material opens the way to the value-added exploitation of wood and widens the processing and application field for the electromagnetic shielding material. In order to explore the feasibility of using NIR technology to investigate the properties of wood electromagnetic shielding material, this study analysis the samples before and after copper plated process by the NIR spectroscopy coupled with principal component analysis (PCA). The results showed that (1) there exist significant differences between samples before and after copper plated process both on the spectral shape and absorption, and the great differences can also be seen in the samples with different treat time, especially for the samples with 5 min treat time; (2) after PCA analysis, six clusters from the samples before and after copper plated process were separately distributed in the score plot, and the properties of untreated wood and sensitized wood were similar, and the properties of samples for 25 and 40 min treat time were also similar in order that these samples were close to each other, all of which might suggest that the NIR spectroscopy reflected major feature information about material treatment; (3) After comparing the PCA performance between NIR and visible spectral region, it could be found that the classification performance of samples before and after copper plated process based on the NIR region were better than that based on the visible region, and the information of color on the surface of samples were preferably reflected in the visible region, which could indicate that there are more information about samples' surface characters using the visible spectroscopy coupled with NIR spectroscopy and it is feasible to

  9. Progress in Anodic Aluminum Oxide Microchannel Plates%阳极氧化铝微通道板研究的进展

    Institute of Scientific and Technical Information of China (English)

    张洋; 黄永刚; 刘辉; 李国恩

    2012-01-01

    微通道板(Microchannel Plates,MCP)是一种先进的电子倍增器件,在微光夜视等多个领域有着广泛的应用.传统铅硅酸盐玻璃微通道板(Lead Silicate Glass Microchannel Plates,LSG-MCP)越来越不能满足小孔径、高分辨率、环境友好等方面的要求,寻求替代产品成为研究热点.详细介绍了一种新型微通道板—阳极氧化铝微通道板(Anodic Aluminum Oxide Microchannel Plates,AAO-MCP)的研究进展,包括多孔AAO的特点、微通道的形成、功能层的制备、计算机模拟等.AAO-MCP具有孔径小、面积大、耐强磁场、工作温度范围宽等特点,应用前景广阔.最后分析了AAO-MCP存在的问题以及未来发展方向.%MicroChannel plates (MCP) are advanced electron multiplier devices, which are widely used in low-light-level night vision and other fields. The traditional lead silicate glass microchannel plates (LSG-MCP) are increasingly unable to meet the requirements of small diameter, high resolution and environment-friendness, so it is necessary to find some novel alternative materials and technology, such as anodic aluminum oxide microchannel plates (AAO-MCP). This paper describes the research progress of the AAO-MCP in details, including the characteristics of the porous AAO, the forming of microchannel, functional film preparation and computer simulation. AAO-MCP has some advantages, such as smaller channel diameter, large area, low sensitivity to strong magnetic field, and wide operating temperature range. Finally, the most difficult problems in AAO-MCP and the development in the future are presented.

  10. MCP-based Photodetectors for Cryogenic Applications

    CERN Document Server

    Dharmapalan, Ranjan; Byrum, Karen; Demarteau, Marcel; Elam, Jeffrey; May, Edward; Wagner, Robert; Walters, Dean; Xia, Lei; Xie, Junqi; Zhao, Huyue; Wang, J

    2016-01-01

    The Argonne MCP-based photo detector is an offshoot of the Large Area Pico-second Photo Detector (LAPPD) project, wherein 6 cm x 6 cm sized detectors are made at Argonne National Laboratory. We have successfully built and tested our first detectors for pico-second timing and few mm spatial resolution. We discuss our efforts to customize these detectors to operate in a cryogenic environment. Initial plans aim to operate in liquid argon. We are also exploring ways to mitigate wave length shifting requirements and also developing bare-MCP photodetectors to operate in a gaseous cryogenic environment.

  11. Salmonella chemoreceptors McpB and McpC mediate a repellent response to L-cystine: a potential mechanism to avoid oxidative conditions.

    Science.gov (United States)

    Lazova, Milena D; Butler, Mitchell T; Shimizu, Thomas S; Harshey, Rasika M

    2012-05-01

    Chemoreceptors McpB and McpC in Salmonella enterica have been reported to promote chemotaxis in LB motility-plate assays. Of the chemicals tested as potential effectors of these receptors, the only response was towards L-cysteine and its oxidized form, L-cystine. Although enhanced radial migration in plates suggested positive chemotaxis to both amino acids, capillary assays failed to show an attractant response to either, in cells expressing only these two chemoreceptors. In vivo fluorescence resonance energy transfer (FRET) measurements of kinase activity revealed that in wild-type bacteria, cysteine and cystine are chemoeffectors of opposing sign, the reduced form being a chemoattractant and the oxidized form a repellent. The attractant response to cysteine was mediated primarily by Tsr, as reported earlier for Escherichia coli. The repellent response to cystine was mediated by McpB/C. Adaptive recovery upon cystine exposure required the methyl-transferase/-esterase pair, CheR/CheB, but restoration of kinase activity was never complete (i.e. imperfect adaptation). We provide a plausible explanation for the attractant-like responses to both cystine and cysteine in motility plates, and speculate that the opposing signs of response to this redox pair might afford Salmonella a mechanism to gauge and avoid oxidative environments.

  12. A magnetic levitation rotating plate model based on high-Tc superconducting technology

    Science.gov (United States)

    Zheng, Jun; Li, Jipeng; Sun, Ruixue; Qian, Nan; Deng, Zigang

    2017-09-01

    With the wide requirements of the training aids and display models of science, technology and even industrial products for the public like schools, museums and pleasure grounds, a simple-structure and long-term stable-levitation technology is needed for these exhibitions. Opportunely, high temperature superconducting (HTS) technology using bulk superconductors indeed has prominent advantages on magnetic levitation and suspension for its self-stable characteristic in an applied magnetic field without any external power or control. This paper explores the feasibility of designing a rotatable magnetic levitation (maglev) plate model with HTS bulks placed beneath a permanent magnet (PM) plate. The model is featured with HTS bulks together with their essential cryogenic equipment above and PMs below, therefore it eliminates the unclear visual effects by spray due to the low temperature coolant such as liquid nitrogen (LN2) and additional levitation weight of the cryogenic equipment. Besides that, a matched LN2 automation filling system is adopted to help achieving a long-term working state of the rotatable maglev plate. The key low-temperature working condition for HTS bulks is maintained by repeatedly opening a solenoid valve and automatically filling LN2 under the monitoring of a temperature sensor inside the cryostat. With the support of the cryogenic devices, the HTS maglev system can meet all requirements of the levitating display model for exhibitions, and may enlighten the research work on HTS maglev applications.

  13. Performance of Small Pore Microchannel Plates

    Science.gov (United States)

    Siegmund, O. H. W.; Gummin, M. A.; Ravinett, T.; Jelinsky, S. R.; Edgar, M.

    1995-01-01

    Small pore size microchannel plates (MCP's) are needed to satisfy the requirements for future high resolution small and large format detectors for astronomy. MCP's with pore sizes in the range 5 micron to 8 micron are now being manufactured, but they are of limited availability and are of small size. We have obtained sets of Galileo 8 micron and 6.5 micron MCP's, and Philips 6 micron and 7 micron pore MCP's, and compared them to our larger pore MCP Z stacks. We have tested back to back MCP stacks of four of these MCP's and achieved gains greater than 2 x 1O(exp 7) with pulse height distributions of less than 40% FWHM, and background rates of less than 0.3 events sec(exp -1) cm(exp -2). Local counting rates up to approx. 100 events/pore/sec have been attained with little drop of the MCP gain. The bare MCP quantum efficiencies are somewhat lower than those expected, however. Flat field images are characterized by an absence of MCP fixed pattern noise.

  14. 316L stainless steel silver plated plate vacuum heat treatment technology%316L不锈钢镀银板的真空热处理工艺

    Institute of Scientific and Technical Information of China (English)

    王红涛

    2012-01-01

      本文分别通过探讨真空环境下热处理温度和热处理时间对316L不锈钢镀银板性能的影响,从而确定316L不锈钢镀银板的最佳真空热处理工艺。%  This paper through the study of the vacuum heat treatment temperature on properties of 316L stainless steel silver plate, so as to determine the optimal 316L stainless steel silver plated vacuum heat treatment technology.

  15. Can Integrated Micro-Optical Concentrator Technology Revolutionize Flat-Plate Photovoltaic Solar Energy Harvesting?

    Science.gov (United States)

    Haney, Michael W.

    2015-12-01

    The economies-of-scale and enhanced performance of integrated micro-technologies have repeatedly delivered disruptive market impact. Examples range from microelectronics to displays to lighting. However, integrated micro-scale technologies have yet to be applied in a transformational way to solar photovoltaic panels. The recently announced Micro-scale Optimized Solar-cell Arrays with Integrated Concentration (MOSAIC) program aims to create a new paradigm in solar photovoltaic panel technology based on the incorporation of micro-concentrating photo-voltaic (μ-CPV) cells. As depicted in Figure 1, MOSAIC will integrate arrays of micro-optical concentrating elements and micro-scale PV elements to achieve the same aggregated collection area and high conversion efficiency of a conventional (i.e., macro-scale) CPV approach, but with the low profile and mass, and hopefully cost, of a conventional non-concentrated PV panel. The reduced size and weight, and enhanced wiring complexity, of the MOSAIC approach provide the opportunity to access the high-performance/low-cost region between the conventional CPV and flat-plate (1-sun) PV domains shown in Figure 2. Accessing this portion of the graph in Figure 2 will expand the geographic and market reach of flat-plate PV. This talk reviews the motivation and goals for the MOSAIC program. The diversity of the technical approaches to micro-concentration, embedded solar tracking, and hybrid direct/diffuse solar resource collection found in the MOSAIC portfolio of projects will also be highlighted.

  16. Characterisation and testing of a prototype $6 \\times 6$ cm$^2$ Argonne MCP-PMT

    CERN Document Server

    Cowan, Greig A; Needham, Matthew; Gambetta, Silvia; Eisenhardt, Stephan; McBlane, Neil; Malek, Matthew

    2016-01-01

    The Argonne micro-channel plate photomultiplier tube (MCP-PMT) is an offshoot of the Large Area Pico-second Photo Detector (LAPPD) project, wherein \\mbox{6 $\\times$ 6 cm$^2$} sized detectors are made at Argonne National Laboratory. Measurements of the properties of these detectors, including gain, time and spatial resolution, dark count rates, cross-talk and sensitivity to magnetic fields are reported. In addition, possible applications of these devices in future neutrino and collider physics experiments are discussed.

  17. Progress of ion plating technology%离子镀膜技术的进展

    Institute of Scientific and Technical Information of China (English)

    王福贞; 刘欢; 那日松

    2014-01-01

    This paper introduced the progress , characteristics , application scope and meaning of the ion plating technology . In the past fifty years ion plating technology conformed to the requirements of high-end products processing and Hi-Tech development , and got rapid development . The emergence of incentive gas discharge technology and the measures to improve the density of plasma met the need in various fields of the thin films . These technology made contribution to national defense , space undertaking , high-tech products and civilian industry products .%本文概括地介绍了五十年来离子镀膜技术的发展概况,介绍了离子镀膜技术的意义、原理、特点、发展和应用范围。从 D 。 M 。 Mattox 发明离子镀膜技术以来的五十年中,离子镀膜技术适应高端产品加工和高新技术发展的要求,得到了飞速发展。各种激励气体放电过程技术,提高等离子体密度的措施层出不穷,满足各种需要的新的薄膜材料在各个应用领域得到了广泛的应用。对国防事业、宇航事业、高新技术产品和美化人民生活做出了突出贡献。我们期待离子镀膜技术继往开来,在新的五十年中再放光彩。

  18. The Processing Technology of Copper Based Microstrip Plate%铜基微带板加工技术

    Institute of Scientific and Technical Information of China (English)

    徐浩平; 薛杉; 胡宁

    2013-01-01

    文章对金属基微带板材料性能进行了简单介绍,对铜基微带板的工艺流程及技术进行了详细说明。%In this paper, the material properties of the metal based microstrip plate are introduced and the process and technology of copper based microstrip plate are described in detail.

  19. Upgrading multilayer zone plate technology for hard x-ray focusing

    Energy Technology Data Exchange (ETDEWEB)

    Hirotomo, Toshiki; Konishi, Shigeki [Graduate School of Material Science, University of Hyogo, Kamigori, Hyogo 678-1297 (Japan); SPring-8 Service Co., Ltd (Japan); Takano, Hidekazu, E-mail: htakano@sci.u-hyogo.ac.jp; Sumida, Kazuhiro; Tsusaka, Yoshiyuki; Kagoshima, Yasushi [Graduate School of Material Science, University of Hyogo, Kamigori, Hyogo 678-1297 (Japan); Koyama, Takahisa [Graduate School of Material Science, University of Hyogo, Kamigori, Hyogo 678-1297 (Japan); Japan Synchrotron Radiation Research Institute (JASRI/SPring-8) (Japan); Ichimaru, Satoshi; Ohchi, Tadayuki [NTT Advanced Technology Corporation (Japan); Takenaka, Hisataka [NTT Advanced Technology Corporation (Japan); TOYAMA Corporation (Japan)

    2016-01-28

    Multilayer zone plate (MZP) technology for hard X-ray focusing was upgraded and its focusing performance was evaluated using 20-keV X-rays at the synchrotron beamline (BL24XU) of SPring-8. The MZP consists of MoSi{sub 2} and Si layers alternately deposited on a glass fiber by magnetron sputtering so that all zone boundaries satisfy the Fresnel zone configuration. The focused beam was evaluated using knife-edge scanning in which the measured intensity distribution is identical to the line spread function (LSF) in the focal plane. The focused beamsize of about 30 nm was estimated by oscillation peaks observed in the measured LSF according to Rayleigh’s criterion.

  20. Silicon-micromachined microchannel plates

    CERN Document Server

    Beetz, C P; Steinbeck, J; Lemieux, B; Winn, D R

    2000-01-01

    Microchannel plates (MCP) fabricated from standard silicon wafer substrates using a novel silicon micromachining process, together with standard silicon photolithographic process steps, are described. The resulting SiMCP microchannels have dimensions of approx 0.5 to approx 25 mu m, with aspect ratios up to 300, and have the dimensional precision and absence of interstitial defects characteristic of photolithographic processing, compatible with positional matching to silicon electronics readouts. The open channel areal fraction and detection efficiency may exceed 90% on plates up to 300 mm in diameter. The resulting silicon substrates can be converted entirely to amorphous quartz (qMCP). The strip resistance and secondary emission are developed by controlled depositions of thin films, at temperatures up to 1200 deg. C, also compatible with high-temperature brazing, and can be essentially hydrogen, water and radionuclide-free. Novel secondary emitters and cesiated photocathodes can be high-temperature deposite...

  1. Evaluation of Metal Connector Plates for Repair of Wood Pallet Stringers

    Science.gov (United States)

    John W. Clarke; Thomas E. McLain; Marshall S. White; Philip A. Araman

    1993-01-01

    Repair of damaged pallets with metal connector plates (MCPs or plates) may reduce woodwaste while providing high quality, economical pallets. This study evaluated some effects of MCP repair on the performance of pallet components and some provisions of a preliminary standard for MCP repair of pallets. Whole pallet stringers and notched segments of stringers were tested...

  2. Field experience and improvements with thin tubular-plate lead/acid technology

    Energy Technology Data Exchange (ETDEWEB)

    Merz, K.D. [CMP Batteries, Bolton (United Kingdom)

    1998-05-18

    The Classic 25 is the product name for a motive-power lead/acid cell using thin positive tubular plates. This cell was developed for use in electric vehicles and other applications where high specific energy and reliable cycle life is required. It would appear that the best approach is to provide a lead/acid battery that has the highest specific energy while still maintaining excellent cycle life. This technology was implemented by use of 6 V modules, followed by a 2-V design. Since this was first introduced in 1989, more than 20 000 cells and monoblocs have been delivered to various electric vehicle applications such as vans, trucks, and buses. The field experience with this product is therefore excellent, and development is continuing on the battery design and manufacturing techniques to improve performance and life even further. Today, a wide range of products using this technology is available, and the latest developments are a new 6 V monobloc and some maintenance-free cells. (orig.)

  3. Making bulk-conductive glass microchannel plates

    Science.gov (United States)

    Yi, Jay J. L.; Niu, Lihong

    2008-02-01

    The fabrication of microchannel plate (MCP) with bulk-conductive characteristics has been studied. Semiconducting clad glass and leachable core glass were used for drawing fibers and making MCP. Co-axial single fiber was drawn from a platinum double-crucible in an automatic fiberizing system, and the fibers were stacked and redrawn into multifiber by a special gripping mechanism. The multifibers were stacked again and the boule was made and sliced into discs. New MCPs were made after chemically leaching process without the traditional hydrogen firing. It was shown that bulk-conductive glass MCP can operate at higher voltage with lower noise.

  4. Development of Intermediate Cooling Technology and Its Control for Two-Stand Plate Rolling

    Directory of Open Access Journals (Sweden)

    Fei Zhang

    2016-01-01

    Full Text Available In a plate rolling production line, thermomechanically controlled processing is critical for plate quality. In this paper, a set of intermediate cooling equipment of a two-stand plate mill with super density nozzles, medium pressure, and small flow is developed. Based on a simplified dynamic model, a cooling control scheme with combined feedforward, feedback, and adaptive algorithms is put forward. The new controlled rolling process and the highly efficient control system improve the controlled rolling efficiency by an average of 17.66%. The proposed intermediate cooling system can also effectively inhibit the growth of austenite grain, improve the impact toughness and yield strength of Q345B steel plate, reduce the formation of secondary oxide scale on the plate surface and the chromatic aberration of the plate surface, and greatly improve the surface quality of the steel plate.

  5. The development of heavy plate production technology%厚板生产技术的发展

    Institute of Scientific and Technical Information of China (English)

    张燕燕; 曹建宁

    2001-01-01

    综述了厚板轧机的发展及其技术改造的特点;介绍了厚板生产TMCP技术的控制环节,立辊轧机的应用以及卷轧中板的生产工艺特点。%The development of heavy plate mill and the common characteristics of the mill revamping were summarized, and the production technologies, such as control links of TMCP, appliction of edger mill and the processing of Steckel mill for plate were introduced.

  6. Detection efficiency evaluation for a large area neutron sensitive microchannel plate detector

    Science.gov (United States)

    Wang, Yi-ming; Tian, Yang; Yang, Yi-gang; Liu, Ren; Pan, Jing-sheng; Wang, Xue-wu; Zhang, Zhi

    2016-09-01

    In this paper, the detection efficiency of a large area neutron sensitive microchannel plate detector has been evaluated. A 6LiF/ZnS scintillator detector 65 mm in diameter and 0.32 mm in thickness, with product code, EJ426HD2, produced by Eljen Technology, was employed as the benchmark detector. The TOF spectra of these two detectors were simultaneously measured and the energy spectra were then deduced to calculate the detection efficiency curve of the nMCP detector. Tests show the detection efficiency@25.3 meV thermal neutrons is 34% for this nMCP detector. Supported by National Natural Science Foundation of China (11375095, 11175098)

  7. Development and tests of MCP based timing and multiplicity detector for MIPs

    Science.gov (United States)

    Feofilov, G.; Kondratev, V.; Stolyarov, O.; Tulina, T.; Valiev, F.; Vinogradov, L.

    2017-01-01

    We present summary of technological developments and tests of the MCP based large area detector aimed at precise timing and charged particles multiplicity measurements. Results obtained in course of these developments of isochronous (simultaneity) precise signal readout, passive summation of 1 ns signals, fast (1 GHz) front-end electronics, miniature vacuum systems, etc. could be potentially interesting for a number of future applications in different fields.

  8. ELENA MCP detector: absolute efficiency measurement for low energy neutral atoms

    Science.gov (United States)

    Rispoli, R.; De Angelis, E.; Colasanti, L.; Vertolli, N.; Orsini, S.; Scheer, J.; Mura, A.; Milillo, A.; Wurz, P.; Selci, S.; Di Lellis, A. M.; Leoni, R.; D'Alessandro, M.; Mattioli, F.; Cibella, S.

    2012-04-01

    MicroChannel plates (MCP) detectors are frequently used in space instrumentation for detecting a wide range of radiation and particles. In particular, the capability to detect non-thermal low energy neutral species is crucial for the sensor ELENA (Emitted Low-Energy Neutral Atoms), part of the package SERENA (Search for Exospheric Refilling and Emitted Natural Abundances) on board the BepiColombo mission to Mercury to be launched in 2014. ELENA is a TOF sensor, based on a novel concept ultra-sonic oscillating shutter (Start section)which is operated at frequencies up to 50 kHz; a MCP detector is used as a Stop section. It is aimed to detect neutral atoms in the range 10 eV - 5 keV, within 70° FOV, perpendicular to the S/C orbital plane. ELENA will monitor the emission of neutral atoms from the whole surface of Mercury thanks to the spacecraft motion. The major scientific objectives are the interaction between the environment and the planet, the global particle loss-rate and the remote sensing of the surface properties. In particular, surface release processes are investigated by identifying particles release from the surface, via solar wind-induced ion sputtering (100 eV) as well as Hydrogen back-scattered at hundreds eV. MCP absolute detection efficiency for very low energy neutral atoms (EMEFISTO facility of the Physical Institute of University of Bern (CH), measurements on three different type of MCPs coating have been performed providing the behaviors of MCP detection efficiency in the range 10eV-1keV. Outcomes from such measurements are here discussed.

  9. MCP detector development for WSO-UV

    Science.gov (United States)

    Diebold, Sebastian; Barnstedt, Jürgen; Elsener, Hans-Rudolf; Ganz, Philipp; Hermanutz, Stephan; Kalkuhl, Christoph; Kappelmann, Norbert; Pfeifer, Marc; Schaadt, Daniel; Schanz, Thomas; Tanirah, Omar; Werner, Klaus

    2012-09-01

    The spectrographs of WSO-UV cover the wavelength range of 102 - 310 nm. The essential requirements for the associated detectors are high quantum effciency, solar blindness, and single photon detection. To achieve this, we develop a microchannel plate detector in a sealed tube. We plan to use cesium activated gallium nitride as semitransparent photocathode, a stack of two microchannel plates and a cross strip anode with advanced readout electronics. Challenges are the degradation of the photocathode under atmospheric conditions and the sealing process. We present the detector concept, details of the transfer and sealing processes under UHV, and the current status.

  10. Cross strip anode readouts for large format, photon counting microchannel plate detectors: developing flight qualified prototypes of the detector and electronics

    Science.gov (United States)

    Vallerga, John; Raffanti, Rick; Cooney, Michael; Cumming, Harley; Varner, Gary; Seljak, Andrej

    2014-07-01

    Photon counting microchannel plate (MCP) imagers have been the detector of choice for most UV astronomical missions over the last two decades (e.g. EUVE, FUSE, COS on Hubble etc.). Over this duration, improvements in the MCP laboratory readout technology have resulted in better spatial resolution (x10), temporal resolution (x1000) and output event rate (x100), all the while operating at lower gain (x 10) resulting in lower high voltage requirements and longer MCP lifetimes. One such technology is the parallel cross strip (PXS) readout. Laboratory versions of PXS electronics have demonstrated count rates on the order of 2 MHz, and temporal resolution of ~ 1ns. In 2012 our group at U.C. Berkeley, along with our partners at the U. Hawaii, received a Strategic Astrophysics Technology grant to raise the TRL of the PXS detector and electronics from 4 to 6 by replacing most of the high powered electronics with application specific integrated circuits (ASICs) which will lower the power, mass and volume requirements of the PXS detector. We were also tasked to design and fabricate a "standard" 50mm square active area MCP detector incorporating these electronics that can be environmentally qualified for flight (temperature, vacuum, vibration). The first ASICs designed for this program have been fabricated and are undergoing testing. We present the latest progress on these ASIC designs and performance and show imaging results from the new 50 x 50 mm XS detector.

  11. New Developments in the Position Sensitive Detectors Based on Microchannel Plates

    Science.gov (United States)

    Tremsin, A. S.; Siegmund, O. H. W.

    2002-11-01

    We report on the latest developments in position sensitive photon counting detectors based on microchannel plates. Substantial improvement of the spatial resolution was achieved with introduction of new readout technology, namely crossed strip (XS) anode, and corresponding processing electronics. The spatial resolution of XS readout appeared to be as small as ~3-4 μm FWHM. Reduction of the total detector gain (down to 106 and potentially lower) without compromising the spatial accuracy allows detector operation at much higher local and global counting rates since the microchannel recharge time becomes smaller. Recent developments of novel microchannel plate technologies provide basis for substantial increase of the spectral sensitivity and quantum efficiency of MCP detectors. We have tested a number of new Silicon micromachined MCPs The new MCP technologies should allow deposition of completely new photocathode materials directly on the front surface of microchannel plates (opaque photocathodes). Opposite to standard glass MCPs new Silicon MCPs can sustain high temperatures (-800 C°) required for the photocathode deposition and activation processes.

  12. Iron Documents. Interdisciplinary studies on the technology of late medieval european plate armour production between 1350 and 1500

    OpenAIRE

    Goll, Matthias

    2014-01-01

    Abstract The purpose of this study is to find out details on the production of late medieval European plate-armour for the field-use. Therefore, the author first collected thousands of extant objects in a database. With this stock of data he then was able to cluster and to structure the armour parts by various typological and technological aspects. To ease the access to the topic, the author defined an understandable and standardized terminology and typology for the different variations of...

  13. Viscoelastic behavior of yellow pitahaya treated with 1-MCP

    National Research Council Canada - National Science Library

    Laura Sofia Torres Valenzuela; Alfredo Adolfo Ayala-Aponte; Liliana Serna

    2016-01-01

    .... The purpose of this work was to evaluate the effect of the application of 1-MCP on the viscoelastic properties of minimally processed yellow pitahaya during refrigeration storage, by using a stress relaxation test...

  14. Monte Carlo Simulations of High-speed, Time-gated MCP-based X-ray Detectors: Saturation Effects in DC and Pulsed Modes and Detector Dynamic Range

    Energy Technology Data Exchange (ETDEWEB)

    Craig Kruschwitz, Ming Wu, Ken Moy, Greg Rochau

    2008-10-31

    We present here results of continued efforts to understand the performance of microchannel plate (MCP)–based, high-speed, gated, x-ray detectors. This work involves the continued improvement of a Monte Carlo simulation code to describe MCP performance coupled with experimental efforts to better characterize such detectors. Our goal is a quantitative description of MCP saturation behavior in both static and pulsed modes. We have developed a new model of charge buildup on the walls of the MCP channels and measured its effect on MCP gain. The results are compared to experimental data obtained with a short-pulse, high-intensity ultraviolet laser; these results clearly demonstrate MCP saturation behavior in both DC and pulsed modes. The simulations compare favorably to the experimental results. The dynamic range of the detectors in pulsed operation is of particular interest when fielding an MCP–based camera. By adjusting the laser flux we study the linear range of the camera. These results, too, are compared to our simulations.

  15. X-ray focusing using microchannel plates

    Science.gov (United States)

    Kaaret, P.; Geissbuehler, P.; Chen, A.; Glavinas, E.

    1992-01-01

    We present measurements of the X-ray focusing properties of square-pore microchannel plates (MCP's). Square-pore MCP's contain large numbers of closely packed optical surfaces, as required for grazing incidence X-ray optics. The surface of individual MCP channels has been measured and found to have high microroughness transverse to the channel axis and low microroughness parallel to the axis. The high frequency transverse roughness, on length scales greater than 400 nm, has a rms value of 5.9 nm and a Gaussian autocorrelation function with correlation length of 1.41 micron. We find that the geometric misalignments of the surfaces of different channels limit the angular resolution obtainable with current samples of MCP's to 7.1 arcmin.

  16. Dexmedetomidine Attenuates Lipopolysaccharide Induced MCP-1 Expression in Primary Astrocyte

    Science.gov (United States)

    Liu, Huan; Faez Abdelgawad, Amro

    2017-01-01

    Background. Neuroinflammation which presents as a possible mechanism of delirium is associated with MCP-1, an important proinflammatory factor which is expressed on astrocytes. It is known that dexmedetomidine (DEX) possesses potent anti-inflammatory properties. This study aimed to investigate the potential effects of DEX on the production of MCP-1 in lipopolysaccharide-stimulated astrocytes. Materials and Methods. Astrocytes were treated with LPS (10 ng/ml, 50 ng/ml, 100 ng/ml, and 1000 ng/ml), DEX (500 ng/mL), LPS (100 ng/ml), and DEX (10, 100, and 500 ng/mL) for a duration of three hours; expression levels of MCP-1 were measured by real-time PCR. The double immunofluorescence staining protocol was utilized to determine the expression of α2-adrenoceptors (α2AR) and glial fibrillary acidic protein (GFAP) on astrocytes. Results. Expressions of MCP-1 mRNA in astrocytes were induced dose-dependently by LPS. Administration of DEX significantly inhibited the expression of MCP-1 mRNA (P < 0.001). Double immunofluorescence assay showed that α2AR colocalize with GFAP, which indicates the expression of α2-adrenoceptors in astrocytes. Conclusions. DEX is a potent suppressor of MCP-1 in astrocytes induced with lipopolysaccharide through α2A-adrenergic receptors, which potentially explains its beneficial effects in the treatment of delirium by attenuating neuroinflammation. PMID:28286770

  17. 纳米材料绿色制版技术的版材研究%Research on the Printing Plate of Green Plate Making Technology Based on Nano-Materials

    Institute of Scientific and Technical Information of China (English)

    周海华; 刘云霞; 宋延林

    2012-01-01

    Plate making is one of the key technologies in printing industry. So far there are mainly two technologies for plate making include laser phototypesetting technology and computer to plate technology. These technologies are based on photosensitive imaging principle, and need chemical treatment processes such as development, fixing etc. Green plate making technology based on nano-materials has many advantages such as pollution free and low cost, as it abandons the i- dea of sensitization imaging. The special nano and micro-structure of the plate will greatly influence the quality of printing products. In this paper, the research on the print plate is briefly introduced. Through optimizing the preparation process of the printing plate, the resolution and printability are greatly improved.%制版技术是印刷产业的关键技术之一。目前的印刷制版技术主要有激光照排制版技术和计算机直接制版技术。这两项制版技术是基于感光成像原理,需要显影、冲洗等化学处理过程。基于纳米材料的绿色制版技术无需感光成像,省略了显影、冲洗等化学处理过程,是一项环境友好、低成本的制版技术。其中,版材的纳微米结构对印刷质量有重要影响。简要介绍具有纳微米结构的版材的制备过程,通过优化版基制备条件,可以有效提高印版的分辨率和印刷适应性。

  18. CCL2/MCP-1 modulation of microglial activation and proliferation

    Directory of Open Access Journals (Sweden)

    Garcia-Bueno Borja

    2011-07-01

    Full Text Available Abstract Background Monocyte chemoattractant protein (CCL2/MCP-1 is a chemokine that attracts cells involved in the immune/inflammatory response. As microglia are one of the main cell types sustaining inflammation in brain, we proposed here to analyze the direct effects of MCP-1 on cultured primary microglia. Methods Primary microglia and neuronal cultures were obtained from neonatal and embryonic Wistar rats, respectively. Microglia were incubated with different concentrations of recombinant MCP-1 and LPS. Cell proliferation was quantified by measuring incorporation of bromodeoxyuridine (BrdU. Nitrite accumulation was measured using the Griess assay. The expression and synthesis of different proteins was measured by RT-PCR and ELISA. Cell death was quantified by measuring release of LDH into the culture medium. Results MCP-1 treatment (50 ng/ml, 24 h did not induce morphological changes in microglial cultures. Protein and mRNA levels of different cytokines were measured, showing that MCP-1 was not able to induce proinflammatory cytokines (IL-1β, IL6, MIP-1α, either by itself or in combination with LPS. A similar lack of effect was observed when measuring inducible nitric oxide synthase (NOS2 expression or accumulation of nitrites in the culture media as a different indicator of microglial activation. MCP-1 was also unable to alter the expression of different trophic factors that were reduced by LPS treatment. In order to explore the possible release of other products by microglia and their potential neurotoxicity, neurons were co-cultured with microglia: no death of neurons could be detected when treated with MCP-1. However, the presence of MCP-1 induced proliferation of microglia, an effect opposite to that observed with LPS. Conclusion These data indicate that, while causing migration and proliferation of microglia, MCP-1 does not appear to directly activate an inflammatory response in this cell type, and therefore, other factors may be

  19. Ultrasonic seam welding technologies of copper plate and tube for collecting solar energy

    Institute of Scientific and Technical Information of China (English)

    汤勇; 万珍平; 刘亚俊; 刘树道

    2003-01-01

    The ultrasonic welding is applied more and more extensively due to its advantages such as environmental protection, cleaning and energy saving. By researching the mechanism on ultrasonic seam welding of copper plates and tubes for collecting solar energy, it is put forward that the ultrasonic metal welding process can be divided into two stages, and two factors make functions jointly to join the welded metal specimens. In order to successfully join the welding, three basic conditions must be satisfied, that is, there should be high frequency friction vibration in the contact interface; pressure must be imposed on the plate specimen during friction vibration; the time of friction vibration and pressure imposed should be proper. Furthermore, how to select the hardness of copper plate and tube and ultrasonic seam welding parameters is analyzed by experiments.

  20. Study on MCP-1 related to inflammation induced by biomaterials

    Energy Technology Data Exchange (ETDEWEB)

    Ding Tingting [Ninth People' s Hospital, School of Medicine, Shanghai Jiao Tong University/Shanghai Biomaterials Research and Testing Center, Shanghai 200023 (China); Sun Jiao [Shanghai Key Laboratory of Stomatology, Shanghai 200023 (China); Zhang Ping, E-mail: jiaosun59@yahoo.co [School of Life Science, East China Normal University, Shanghai 200062 (China)

    2009-06-15

    The study of inflammation is important for understanding the reaction between biomaterials and the human body, in particular, the interaction between biomaterials and immune system. In the current study, rat macrophages were induced by multiple biomaterials with different biocompatibilities, including polyvinyl chloride (PVC) containing 8% of organic tin, a positive control material with cellular toxicity. Human umbilical vein endothelial cells (ECV-304), cultured with PRMI-1640, were detached from cells cultured with the supernatant of macrophages containing TNF-alpha and IL-1beta because of stimulation by biomaterials. The cells were then treated with different biomaterials. Then both TNF-alpha and IL-1beta in macrophages were detected by ELISA. Levels of monocyte chemoattractant protein-1 (MCP-1) were measured by RT-PCR. The results suggested that the expression of TNF-alpha and IL-1beta was elevated by polytetrafluoroethylene (PTFE), polylactic-co-glycolic acid (PLGA) and American NPG alloy (p < 0.001). The level of MCP-1 cultured in supernatant of macrophages was higher than in PRMI-1640 with the same biomaterials. And the exposure to PTFE, PLGA and NPG resulted in the high expression of MCP-1 (p < 0.001) following cytokine stimulation. MCP-1 was also significantly expressed in beta-tricalcium phosphate (beta-TCP) and calcium phosphate cement samples (CPC) (p < 0.01). Thus, TNF-alpha, IL-1beta and MCP-1 had played an important role in the immune reaction induced by biomaterials and there was a close relationship between the expression of cytokines and biomcompatibility of biomaterials. Furthermore, these data suggested that MCP-1 was regulated by TNF-alpha and IL-1beta, and activated by both cytokines and biomaterials. The data further suggested that the expression of MCP-1 could be used as a marker to indicate the degree of immune reaction induced by biomaterials.

  1. Ethylene and 1-MCP affect the postharvest behavior of yellow pitahaya fruits (Selenicereus megalanthus Haw.

    Directory of Open Access Journals (Sweden)

    Yuli Alexandra Deaquiz

    2014-04-01

    Full Text Available The pitahaya or dragon fruit is one of the most representative exotic fruits that Colombia has, with an important, growing international market, but the cultivation and postharvest of this fruit lack sufficient technological support to be more competitive. Therefore, alternatives that provide good-quality products that meet market requirements are very important. Therefore, the objective of this research was to determine the effect of a ripening retardant and ethylene application on the conservation and quality of pitahaya fruits and the possible changes during ripening associated with ethylene, for which a completely randomized design with three treatments was used, corresponding to the application of ethylene (ethephon, 3 mL L-1, 1-methylcyclopropene (1-MCP, 600 mg L-1 and a control, with four replications, for a total of 12 experimental units. The fruits were stored at 18°C with 75% relative humidity. The 1-MCP application significantly decreased the loss of firmness, total soluble solids, loss of fresh mass and respiratory rate. Fruits from the control and ethylene treatment tended toward a climateric respiratory behavior. The total carotenoid content of the fruits was significantly higher in the ethylene application and the control treatment, which was consistent with the color change of the fruits. It can be concluded that the 1-MCP application reduced the ethylene action, slowing the ripening of the dragon fruits.

  2. State of art report for high temperature wear test of SMART MCP and CEDM bearing material

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Hu; Lee, Jae Seon; Park, Jin Seok; Kim, Ji Ho; Kim, Jong In

    2000-03-01

    Wear resistance properties of machine elements has been more critical in view of its significant effect on life extension, economics and material saving because it has been recognized that nearly 80 percent of damages of mechanical elements in the friction pairs are due to the material loss by wear. And wear properties have direct influence on the life of a machine in a great extend under extremely severe operating condition. Therefore highly improved wear properties of machine elements operating in such circumstances is heavily required. The purpose of this report is to survey current technology for high temperature wear test in order to establish the test plan for the life evaluation of SMART MCP and CEDM bearing materials. Friction and wear test will be done under high pressure (170 MPa) and high temperature (350 degree C) with water as lubricant to simulate the operating condition of the nuclear power reactor. Because pump type for MCP is selected as the caned motor pump which needs no mechanical sealing, the rotating shaft on which bearing is fully submerged by main coolant with high temperature. So MCP bearing operates without additional lubricant. CEDM is adopted as the ball-screw type with fine controllability. So the driving part is designed as the immersed-in type by main coolant. Therefore the anti-wear and reliability of driving parts are much consequent to guarantee the lifetime and the safety of the whole system. Tribometer adapted to high temperature and pressure circumstance is needed to execute bearing material testing. Test parameters are material, sliding speed, sliding distance and applied load. In order to identify the wear mechanism, optical microscope and surface roughness testers are required. The result of this report will provide an elementary data to develop bearing materials and to estimate bearing lifetime for the bearings of MCP and CEDM in SMART. (author)

  3. State of art report for high temperature wear test of SMART MCP and CEDM bearing material

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Hu; Lee, Jae Seon; Park, Jin Seok; Kim, Ji Ho; Kim, Jong In

    2000-03-01

    Wear resistance properties of machine elements has been more critical in view of its significant effect on life extension, economics and material saving because it has been recognized that nearly 80 percent of damages of mechanical elements in the friction pairs are due to the material loss by wear. And wear properties have direct influence on the life of a machine in a great extend under extremely severe operating condition. Therefore highly improved wear properties of machine elements operating in such circumstances is heavily required. The purpose of this report is to survey current technology for high temperature wear test in order to establish the test plan for the life evaluation of SMART MCP and CEDM bearing materials. Friction and wear test will be done under high pressure (170 MPa) and high temperature (350 degree C) with water as lubricant to simulate the operating condition of the nuclear power reactor. Because pump type for MCP is selected as the caned motor pump which needs no mechanical sealing, the rotating shaft on which bearing is fully submerged by main coolant with high temperature. So MCP bearing operates without additional lubricant. CEDM is adopted as the ball-screw type with fine controllability. So the driving part is designed as the immersed-in type by main coolant. Therefore the anti-wear and reliability of driving parts are much consequent to guarantee the lifetime and the safety of the whole system. Tribometer adapted to high temperature and pressure circumstance is needed to execute bearing material testing. Test parameters are material, sliding speed, sliding distance and applied load. In order to identify the wear mechanism, optical microscope and surface roughness testers are required. The result of this report will provide an elementary data to develop bearing materials and to estimate bearing lifetime for the bearings of MCP and CEDM in SMART. (author)

  4. Plate-like structure health monitoring based on ultrasonic guided wave technology by using bonded piezoelectric ceramic wafers

    Science.gov (United States)

    Liu, Zenghua; Zhao, Jichen; He, Cunfu; Wu, Bin

    2008-11-01

    Piezoelectric ceramic wafers are applied for the excitation and detection of ultrasonic guided waves to determine the health state of plate-like structures. Two PZT wafers, whose diameter is 11mm and thickness is 0.4mm respectively, are bonded permanently on the surface of a 1mm thick aluminum plate. One of these wafers is actuated by sinusoidal tone burst at various frequencies ranging from 100kHz to 500kHz, the other one is used as a receiver for acquiring ultrasonic guided wave signals. According to the amplitudes and shapes of these received signals, guided wave modes and their proper frequency range by using these wafers are determined. For the improvement of the signal-to-noise ratio, the Daubechies wavelet of order 40 is used for signal denoising as the mother wavelet. Furthermore, the detection of an artificial cylindrical through-hole defect is achieved by using S0 at 300kHz. Experimental results show that it is feasible and effective to detect defects in plate-like structures based on ultrasonic guided wave technology by using bonded piezoelectric ceramic wafers.

  5. YAG Laser Face Joining Technology of A6061 Aluminium and SPCC Plates

    Science.gov (United States)

    NISHIMOTO, K.; MARUO, T.; OUMI, M.; SEI, N.; FUJII, H.

    Laser and pressure roll combination joining tests on SPCC-A6061 plates were carried out by changing the roll pressure. Adhesive strengths on SPCC-A6061 were measured by peel tests. When the pressure increased from 80 MPa to 320 MPa, the adhesive strength increased from 10 N/mm to 30 N/mm. It was obvious that the higher pressure brought some good influence to the joint interface of the metals. From observation results on the joint layer by EDX, we recognized ductile compounds Fe3Al and metallic bonds when 320 MPa pressure was laid on by twin rolls. Moreover, it resulted in the achievement of high adhesive strength during the joining of SPCC-A6061 plates.

  6. Development and testing of cost-effective, 6 cm x 6 cm MCP-based photodetectors for fast timing applications

    CERN Document Server

    Wang, Jingbo; Demarteau, Marcel; Elam, Jeffrey; Mane, Anil; May, Edward; Wagner, Robert; Walters, Dean; Xie, Junqi; Xia, Lei; Zhao, Huyue

    2016-01-01

    Micro-channel plate (MCP)-based photodetectors are capable of picosecond level time resolution and sub-mm level position resolution, which makes them a perfect candidate for the next generation large area photodetectors. The large-area picosecond photodetector (LAPPD) collaboration is developing new techniques for making large-area photodetectors based on new MCP fabrication and functionalization methods. A small single tube processing system (SmSTPS) was constructed at Argonne National Laboratory (ANL) for developing scalable, cost-effective, glass-body, 6 cm x 6 cm, picosecond photodetectors based on MCPs functionalized by Atomic Layer Deposition (ALD). Recently, a number of fully processed and hermitically sealed prototypes made of MCPs with 20 micron pores have been fabricated. This is a significant milestone for the LAPPD project. These prototypes were characterized with a pulsed laser test facility. Without optimization, the prototypes have shown excellent results: The time resolution is ~57 ps for sing...

  7. ELENA MCP detector: absolute detection efficiency for low-energy neutral atoms

    Science.gov (United States)

    Rispoli, R.; De Angelis, E.; Colasanti, L.; Vertolli, N.; Orsini, S.; Scheer, J. A.; Mura, A.; Milillo, A.; Wurz, P.; Selci, S.; Di Lellis, A. M.; Leoni, R.; D'Alessandro, M.; Mattioli, F.; Cibella, S.

    2012-09-01

    Microchannel Plates (MCP) detectors are frequently used in space instrumentation for detecting a wide range of radiation and particles. In particular, the capability to detect non-thermal low energy neutral species is crucial for the sensor ELENA (Emitted Low-Energy Neutral Atoms), part of the package SERENA (Search for Exospheric Refilling and Emitted Natural Abundances) on board the BepiColombo mission of ESA to Mercury to be launched in 2015. ELENA is a Time of Flight (TOF) sensor, based on a novel concept using an ultra-sonic oscillating shutter (Start section), which is operated at frequencies up to 50 kHz; a MCP detector is used as a Stop detector. The scientific objective of ELENA is to detect energetic neutral atoms in the range 10 eV - 5 keV, within 76° FOV, perpendicular to the S/C orbital plane. ELENA will monitor the emission of neutral atoms from the whole surface of Mercury thanks to the spacecraft motion. The major scientific objectives are the interaction between the plasma environment and the planet’s surface, the global particle loss-rate and the remote sensing of the surface properties. In particular, surface release processes are investigated by identifying particles released from the surface, via solar wind-induced ion sputtering (MEFISTO facility of the Physical Institute of the University of Bern (CH), measurements on three different types of MCP (with and without coating) have been performed providing the detection efficiencies in the energy range 10eV - 1keV. Outcomes from such measurements are discussed here.

  8. MicroCameras and Photometers (MCP) on board TARANIS satellite

    Science.gov (United States)

    Farges, Thomas; Blanc, Elisabeth; Hébert, Philippe; Le Mer-Dachard, Fanny; Ravel, Karen; Gaillac, Stéphanie

    2017-04-01

    TARANIS (Tool for the Analysis of Radiations from lightNings and Sprites) is a CNES micro satellite. Its main objective is to study impulsive transfers of energy between the Earth atmosphere and the space environment. It will be sun-synchronous at an altitude of 700 km. It will be launched from end-2018 for at least 2 years. Its payload is composed of several electromagnetic instruments in different wavelengths (from gamma-rays to radio waves including optical). TARANIS instruments are currently in calibration and qualification phase. The purpose of this poster is to present the MicroCameras and Photometers (MCP) scientific objectives and the sensor design, to show the performances of this instrument using the recent characterization, and at last to promote its products. The MicroCameras, developed by Sodern, are dedicated to the spatial description of TLEs and their parent lightning. They are able to differentiate sprite and lightning thanks to two narrow bands ([757-767 nm] and [772-782 nm]) that provide simultaneous pairs of images of an Event. Simulation results of the differentiation method will be shown. After calibration and tests, the MicroCameras are now delivered to CNES for integration on the payload. The Photometers, developed by Bertin Technologies, will provide temporal measurements and spectral characteristics of TLEs and lightning. There are key instrument because of their capability to detect on-board TLEs and then switch all the instruments of the scientific payload in their high resolution acquisition mode. Photometers use four spectral bands in the [170-260 nm], [332-342 nm], [757-767 nm] and [600-900 nm] and have the same field of view as cameras. The on-board TLE detection algorithm remote-controlled parameters have been tuned before launch using the electronic board and simulated or real events waveforms. The Photometers are now in the calibration and test phase. They will be delivered for integration in mid-2017.

  9. Angular Sensitivity of Gated Micro-Channel Plate Framing Cameras

    Energy Technology Data Exchange (ETDEWEB)

    Landen, O L; Lobban, A; Tutt, T; Bell, P M; Costa, R; Ze, F

    2000-07-24

    Gated, microchannel-plate-based (MCP) framing cameras have been deployed worldwide for 0.2 - 9 keV x-ray imaging and spectroscopy of transient plasma phenomena. For a variety of spectroscopic and imaging applications, the angular sensitivity of MCPs must be known for correctly interpreting the data. We present systematic measurements of angular sensitivity at discrete relevant photon energies and arbitrary MCP gain. The results can been accurately predicted by using a simple 2D approximation to the 3D MCP geometry and by averaging over all possible photon ray paths.

  10. A Compact Immunoassay Platform Based on a Multicapillary Glass Plate

    OpenAIRE

    Shuhua Xue; Hulie Zeng; Jianmin Yang; Hizuru Nakajima; Katsumi Uchiyama

    2014-01-01

    A highly sensitive, rapid immunoassay performed in the multi-channels of a micro-well array consisting of a multicapillary glass plate (MCP) and a polydimethylsiloxane (PDMS) slide is described. The micro-dimensions and large surface area of the MCP permitted the diffusion distance to be decreased and the reaction efficiency to be increased. To confirm the concept of the method, human immunoglobulin A (h-IgA) was measured using both the proposed immunoassay system and the traditional 96-well ...

  11. Nanosecond-gating properties of proximity-focused microchannel-plate image intensifiers

    Science.gov (United States)

    King, N. S. P.; Yates, G. J.; Jaramillo, S. A.; Ogle, J. W.

    Some fundamental properties of 18 mm-diam gated proximity focussed microchannel plate (MCP) image intensifiers used as fast image shutters in the 1 to 10 ns range were identified and studied. Light pulses from a modelocked dye laser optically sample the gated MCP. Shuttering is achieved by applying a forward biasing electrical gate pulse to the quiescently reverse-biased photocathode MCP interface. Variable delay between the gate pulse and the laser pulse permits tracing the MCP's optical response. Gating speeds, turn-on and turn-off patterns, the asymmetric spatial depedence of the MCP optical response, and resolution effects as functions of gate pulse width and photocathode-MCP bias were characterized. Variations in the intensity profiles of the phosphor's spatial response for uniform photocathode illumination are measured with a calibrated silicon intensified target focus projection, scan television camera and a high speed video digitizer while photomultipliers monitor the laser pulse and the phosphor's spatially integrated output intensities.

  12. Recent progress in optical coating technology: low-voltage ion plating deposition

    Science.gov (United States)

    Guenther, Karl H.

    1990-08-01

    After fairly extensive discussions of the advantages and disadvantages of low energy and high energy ion beam bombardment of a growing film, we review briefly a number of experimental results obtained with various samples made with low voltage reactive ion plating deposition. The availability of a state-of-the-art high vacuum coating machine specifically equipped for this process is the foundation for a major leap toward achieving near-perfect optical coatings. The high density of ion plated thin films makes them impermeable to water vapor and corrosive solutions. This has been demonstrated with protected aluminum mirrors, polarizers, and infrared anti-reflection coatings. An indication of the high packing density is the substantially higher refractive index than that of comparable layers deposited with either conventional electron beam evaporation or ion assisted deposition. The spectral transmittance of multilayer stacks of oxide thin films is lower than expected from theoretical predictions which assume absorption-free dielectrics. The observed absorption is primarily of an interface nature rather than a volume effect and occurs predominantly in combinations of Ti02 and Si02 thin films.

  13. Processless offset printing plates

    Directory of Open Access Journals (Sweden)

    Sanja Mahović Poljaček

    2015-06-01

    Full Text Available With the implementation of platesetters in the offset printing plate making process, imaging of the printing plate became more stable and ensured increase of the printing plate quality. But as the chemical processing of the printing plates still highly influences the plate making process and the graphic reproduction workflow, development of printing plates that do not require chemical processing for offset printing technique has been one of the top interests in graphic technology in the last few years. The main reason for that came from the user experience, where majority of the problems with plate making process could be connected with the chemical processing of the printing plate. Furthermore, increased environmental standards lead to reducing of the chemicals used in the industrial processes. Considering these facts, different types of offset printing plates have been introduced to the market today. This paper presents some of the processless printing plates.

  14. High resolution MCP photon detectors for the PANDA endcap disc DIRC

    Energy Technology Data Exchange (ETDEWEB)

    Rieke, Julian; Biguenko, Klim; Dueren, Michael; Etzelmueller, Erik; Hayrapetyan, Avetik; Kroeck, Benno; Merle, Oliver; Schmidt, Mustafa [II. Physikalisches Institut, Justus-Liebig-Universitaet, Giessen (Germany); Foehl, Klaus [CERN, Genf (Switzerland); Collaboration: PANDA-Collaboration

    2015-07-01

    The PANDA detector at the future FAIR facility in Darmstadt will require excellent particle identification (PID) to achieve its physics goals. The forward region between 5 and 22 degrees will be instrumented with a novel Disc DIRC detector which utilizes internally reflected Cherenkov light and will provide separation of pions, kaons and protons with momenta up to 4 GeV/c. The Cherenkov photon readout will be carried out with high resolution microchannel plate photomultiplier tubes (MCP-PMTs). A custom made anode layout with a narrow strip pitch of 0.5 mm will allow the reconstructing of the point of impact of single photons with high precision. The tubes will be read out by a modified version of the TOFPET ASIC. The current status of the prototype testing of the tubes and the ASIC is presented.

  15. Capacitively coupled pickup in MCP-based photodetectors using a conductive metallic anode

    CERN Document Server

    Angelico, Evan; Adams, Bernhard; Elagin, Andrey; Frisch, Henry; Spieglan, Eric

    2016-01-01

    We have designed and tested a robust 20 $\\times$ 20 cm$^2$ thin metal film internal anode capacitively coupled to an external array of signal pads or micro-strips for use in fast microchannel plate photodetectors. The internal anode, in this case a 10nm-thick NiCr film deposited on a 96% pure Al$_2$O$_3$ 3mm-thick ceramic plate and connected to HV ground, provides the return path for the electron cascade charge. The multi-channel pickup array consists of a printed-circuit card or glass plate with metal signal pickups on one side and the signal ground plane on the other. The pickup can be put in close proximity to the bottom outer surface of the sealed photodetector, with no electrical connections through the photodetector hermetic vacuum package other than a single ground connection to the internal anode. Two pickup patterns were tested using a small commercial MCP-PMT as the signal source: 1) parallel 50$\\Omega$ 25-cm-long micro-strips with an analog bandwidth of 1.5 GHz, and 2) a 20 $\\times$ 20 cm$^2$ array...

  16. An Internal ALD-Based High Voltage Divider and Signal Circuit for MCP-based Photodetectors

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Bernhard W.; Elagin, Andrey; Elam, Jeffrey W.; Frisch, Henry J.; Genat, Jean-Francois; Gregar, Joseph S.; Mane, Anil U.; Minot, Michael J.; Northrup, Richard; Obaid, Razib; Oberla, Eric; Alexander, Vostrikov; Wetstein, Matthew

    2015-04-21

    We describe a pin-less design for the high voltage (HV) resistive divider of the all-glass LAPPD (TM) 8 in,square thin photodetector module. The divider, which distributes high voltage applied to the photocathode to the two micro-channel plates (MCPs) that constitute the amplification stage, is comprised of the two MCPs and three glass mechanical spacers, each of which is coated with a resistive layer using atomic layer deposition (ALD). The three glass grid spacers and the two MCPs form a continuous resistive path between cathode and anode, with the voltages across the MCPs and the spacers determined by the resistance of each. High voltage is applied on an external tab on the top glass window that connects to the photocathode through the metal seal. The DC ground is supplied by microstrips on the bottom glass plate that form the high-bandwidth anode. The microstrips exit the package through the glass-frit seal of the anode base-plate and the package sidewall. The divider is thus completely internal, with no HV pins penetrating the low-profile flat glass package. Measurements of the performance of the divider are presented for the 8 in.-square MCP and spacer package in a custom test fixture and for an assembled externally pumped LAPPD (TM) prototype with an aluminum photocathode. (C) 2015 Elsevier B.V. All rights reserved.

  17. Silicon-micromachined microchannel plates

    Energy Technology Data Exchange (ETDEWEB)

    Beetz, Charles P. E-mail: NanoSystem@aol.com; Boerstler, Robert; Steinbeck, John; Lemieux, Bryan; Winn, David R. E-mail: winn@fair1.fairfield.edu

    2000-03-11

    Microchannel plates (MCP) fabricated from standard silicon wafer substrates using a novel silicon micromachining process, together with standard silicon photolithographic process steps, are described. The resulting SiMCP microchannels have dimensions of {approx}0.5 to {approx}25 {mu}m, with aspect ratios up to 300, and have the dimensional precision and absence of interstitial defects characteristic of photolithographic processing, compatible with positional matching to silicon electronics readouts. The open channel areal fraction and detection efficiency may exceed 90% on plates up to 300 mm in diameter. The resulting silicon substrates can be converted entirely to amorphous quartz (qMCP). The strip resistance and secondary emission are developed by controlled depositions of thin films, at temperatures up to 1200 deg. C, also compatible with high-temperature brazing, and can be essentially hydrogen, water and radionuclide-free. Novel secondary emitters and cesiated photocathodes can be high-temperature deposited or nucleated in the channels or the first strike surface. Results on resistivity, secondary emission and gain are presented.

  18. Silicon-micromachined microchannel plates

    Science.gov (United States)

    Beetz, Charles P.; Boerstler, Robert; Steinbeck, John; Lemieux, Bryan; Winn, David R.

    2000-03-01

    Microchannel plates (MCP) fabricated from standard silicon wafer substrates using a novel silicon micromachining process, together with standard silicon photolithographic process steps, are described. The resulting SiMCP microchannels have dimensions of ˜0.5 to ˜25 μm, with aspect ratios up to 300, and have the dimensional precision and absence of interstitial defects characteristic of photolithographic processing, compatible with positional matching to silicon electronics readouts. The open channel areal fraction and detection efficiency may exceed 90% on plates up to 300 mm in diameter. The resulting silicon substrates can be converted entirely to amorphous quartz (qMCP). The strip resistance and secondary emission are developed by controlled depositions of thin films, at temperatures up to 1200°C, also compatible with high-temperture brazing, and can be essentially hydrogen, water and radionuclide-free. Novel secondary emitters and cesiated photocathodes can be high-temperature deposited or nucleated in the channels or the first strike surface. Results on resistivity, secondary emission and gain are presented.

  19. INNOVATIVE TECHNOLOGIES OF THE METAL-PLATE SPRINGS PRODUCTION AND HARDENING

    Directory of Open Access Journals (Sweden)

    V. V. Klubovich

    2010-01-01

    Full Text Available A methods and technology of the periodic rolling billets variable profile. Given schematic diagrams and technical specification of equipment for making plastic and surface treatment of small leaf springs and the guide bearings air suspension trucks. An assessment of the influence of ultrasonic vibrations on the structure and operating characteristics of the elastic elements of the suspension of vehicles.

  20. Balanced Flow Measurement and Conditioning Technology (Balanced Orifice Plate 7,051,765 B1) for NASA Inventions and Contributions Board Invention of the Year Evaluation

    Science.gov (United States)

    Kelley, Anthony R.

    2008-01-01

    This viewgraph document reviews the Balanced Flow Measurement (BFM) and Conditioning Technology, and makes the case for this as the NASA Invention of the Year. The BFM technology makes use of a thin, multi-hole orifice plate with holes sized and placed per a unique set of equations. It produces mass flow, volumetric flow,kinelic energy,or momentum BALANCE across the face of the plate. The flow is proportional.to the square root of upstream to downstream differential pressure. Multiple holes lead to smoother pressure measurement. Measures and conditions or can limit fluid flow. This innovation has many uses in and out of NASA.

  1. Fabrication of nanocomposite electrode based on Bi{sub 4−x}Nd{sub x}Ti{sub 3}O{sub 12} perovskite supported by silicon microchannel plates for high performance electrochemical capacitors

    Energy Technology Data Exchange (ETDEWEB)

    Miao, Fengjuan [College of Communications and Electronics Engineering, Qiqihar University, Heilongjiang 161006 (China); National Laboratory for Infrared Physics, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083 (China); Tao, Bairui, E-mail: tbr_sir@163.com [College of Communications and Electronics Engineering, Qiqihar University, Heilongjiang 161006 (China); National Laboratory for Infrared Physics, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083 (China); Computer Center, Qiqihar University, Heilongjiang 161006 (China); Chu, Paul K. [Department of Physics and Materials Sciences, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong (China)

    2015-01-15

    Highlights: • Bi{sub 4−x}Nd{sub x}Ti{sub 3}O{sub 12}/Ni/Si-MCP is an excellent electrode for electrochemical capacitors. • The electrodes provide large specific surface areas. • This research may provide a meaning way in integratable electrochemical capacitors. - Abstract: A novel self-standing Bi{sub 4−x}Nd{sub x}Ti{sub 3}O{sub 12} electrodes structure based on the three dimensional silicon microchannel plates (Si-MCP) is proposed for electrochemical capacitors. In order to decrease electron transfer barrier and contact resistance, the Ni/Si-MCP compound materials were synthesized as current collectors by electroless plating. The Bi{sub 4−x}Nd{sub x}Ti{sub 3}O{sub 12} perovskite were distributed on the channel of Ni/Si-MCP compound structure by sol–gel techniques. The morphology and microstructure of as-synthesized mesoporous Bi{sub 4−x}Nd{sub x}Ti{sub 3}O{sub 12} (BNT) were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD). The electrodes have not only excellent capacitive performances, but also superior electrochemical stability. Owing to the formation of thin film morphology, porous structure, ordered channel and the intimate contact between the electroactive material and the current collector, the BNT/Ni/Si-MCP electrodes provide an enhancement of the kinetics by short transport/diffusion path lengths, timely accompanying of electrolyte and large specific surface areas, thus both high energy density and high power density are achieved. In particular, since the fabrication process is compatible with conventional silicon technology, the structure has immense potential as integrated supercapacitors.

  2. Development of micromachined preconcentrators and gas chromatographic separation columns by an electroless gold plating technology

    Science.gov (United States)

    Kuo, C.-Y.; Chen, P.-S.; Chen, H.-T.; Lu, C.-J.; Tian, W.-C.

    2017-03-01

    In this study, a simple process for fabricating a novel micromachined preconcentrator (μPCT) and a gas chromatographic separation column (μSC) for use in a micro gas chromatograph (μGC) using one photomask is described. By electroless gold plating, a high-surface-area gold layer was deposited on the surface of channels inside the μPCT and μSC. For this process, (3-aminopropyl) trimethoxysilane (APTMS) was used as a promoter for attaching gold nanoparticles on a silicon substrate to create a seed layer. For this purpose, a gold sodium sulfite solution was used as reagent for depositing gold to form heating structures. The microchannels of the μPCT and μSC were coated with the adsorbent and stationary phase, Tenax-TA and polydimethylsiloxane (DB-1), respectively. μPCTs were heated at temperatures greater than 280 °C under an applied electrical power of 24 W and a heating rate of 75 °C s‑1. Repeatable thermal heating responses for μPCTs were achieved; good linearity (R 2  >  0.9997) was attained at three heating rates for the temperature programme for the μSC (0.2, 0.5 and 1 °C s‑1). The volatile organic compounds (VOCs) toluene and m-xylene were concentrated over the μPCT by rapid thermal desorption (peak width of half height (PWHH)  7900. The VOCs acetone, benzene, toluene, m-xylene and 1,3,5-trimethylbenzene were also separated on the μSC as evidenced by their different retention times (47–184 s).

  3. Cross strip anode readouts for microchannel plate detectors: developing flight qualified prototypes

    Science.gov (United States)

    Vallerga, John; Cooney, M.; Raffanti, R.; Varner, G.; Siegmund, O.; McPhate, J. B.; Tremsin, A.

    2014-01-01

    Photon counting microchannel plate (MCP) imagers have been the detector of choice for most UV astronomical missions over the last two decades (eg. EUVE, FUSE, COS on Hubble etc.). Over this duration, improvements in the MCP laboratory readout technology have resulted in better spatial resolution (x10), temporal resolution (x 1000) and output event rate (x100), all the while operating at lower gain (x 10) resulting in lower high voltage requirements and longer MCP lifetimes. One such technology is the parallel cross strip (PXS) readout. The PXS anode is a set of orthogonal conducting strips (80 x 80), typically spaced at a 635 micron pitch onto which charge clouds from MCP amplified events land. Each strip has its own charge sensitive amplifier that is sampled continuously by a dedicated analog to digital (ADC) converter at 50MHz. All of the 160 ADC digital output lines are fed into a field programmable gate array (FGPA) which can detect charge events landing on the strips, measure the peak amplitudes of those charge events and calculate their spatial centroid along with their time of arrival (X,Y,T). Laboratory versions of these electronics have demonstrated count rates on the order of 2 MHz, and temporal resolution of ~ 1ns. In 2012 the our group at U.C. Berkeley, along with our partners at the U. Hawaii, received a Strategic Astrophysics Technology grant to raise the TRL of the PXS detector from 4 to 6 by replacing most of the 19" rack mounted, high powered electronics with application specific integrated circuits (ASICs) which will lower the power, mass and volume requirements of the PXS detector. We were also tasked to design and fabricate a "standard" 50mm square active area MCP detector incorporating these electronics that can be environmentally qualified for flight (temperature, vacuum, vibration). This detector design could then be modified for individual flight opportunities with a higher level of confidence than starting from scratch. We will present the

  4. Microchannel Plates for the UVCS and SUMER Instruments on the SOHO Satellite

    Science.gov (United States)

    Siegmund, O. H. W.; Gummin, M. A.; Sasseen, T.; Jelinsky, P.; Gaines, G. A.; Hull, J.; Stock, J. M.; Edgar, M.; Welsh, B.; Jelinsky, S.; Vallerga, J.

    1995-01-01

    The microchannel plates for the detectors in the SUMER (Solar Ultraviolet Measurements of Emitted Radiation) and UVCS (Ultraviolet Coronograph Spectrometer) instruments aboard the Solar Orbiting Heliospheric Observatory (SOHO) mission to be launched in late 1995 are described. A low resistance Z stack of microchannel plates (MCP's) is employed in a detector format of 27 mm x 10 mm using a multilayer cross delay line anode (XDL) with 1024 x 360 digitized pixels. The MCP stacks provide gains of greater than 2 x 10(exp 7) with good pulse height distributions (as low as 25% FWHM) under uniform flood illumination. Background rates of approx. 0.6 event cm(exp -2) sec(exp -1) are obtained for this configuration. Local counting rates up to about 800 events/pixel/sec have been achieved with little drop of the MCP gain. MCP preconditioning results are discussed, showing that some MCP stacks fail to have gain decreases when subjected to a high flux UV scrub. Also, although the bare MCP quantum efficiencies are close to those expected (10%), we found that the long wavelength response of KBr photocathodes could be substantially enhanced by the MCP scrubbing process. Flat field images are characterized by a low level of MCP fixed pattern noise and are stable. Preliminary calibration results for the instruments are shown.

  5. VIDA COMERCIAL DE PITAHAYA AMARILLA TRATADA CON 1-MCP

    Directory of Open Access Journals (Sweden)

    LILIANA SERNA-COCK

    Full Text Available 1-metilciclopropeno (1-MCP, un inhibidor del etileno, ha sido utilizado para extender la vida comercial de diferentes frutas. El objetivo de este trabajo fue evaluar el efecto de la aplicación de soluciones acuosas de 10, 100 y 200 gL-1 de 1-MCP, con tiempos de exposición de 1, 5 y 10 minutos, sobre la vida comercial de pitahaya amarilla en estado de madurez 4. Durante 15 días de almacenamiento (25 ± 2°C y 75% de humedad relativa, se evaluaron cambios físicos como la pérdida de peso y la aparición de pardeamiento; y se midieron cambios químicos como sólidos solubles, pH, acidez e índice de madurez. Se presentaron diferencias significativas entre los tratamientos. Los resultados demostraron que aplicaciones de 200 gL-1 de 1-MCP durante 10 minutos prolongó por tres días, la vida comercial de la pitahaya amarilla, y redujo cambios en los sólidos solubles y la acidez

  6. Overview - Flat-plate technology. [review of Low Cost Solar Array Project

    Science.gov (United States)

    Callaghan, W. T.

    1981-01-01

    Progress and continuing plans for the joint NASA/DoE program at the JPL to develop the technologies and industrial processes necessary for mass production of low-cost solar arrays (LSA) which produce electricity from solar cells at a cost of less than $0.70/W are reviewed. Attention is given to plans for a demonstration Si refinement plant capable of yielding 1000 MT/yr, and to a CVD process with chlorosilane, which will yield material at a cost of $21/kg. Ingot and shaped-sheet technologies, using either Czochralski growth and film fed growth methods have yielded AM1 15% efficient cells in an automated process. Encapsulation procedures have been lowered to $14/sq m, and robotics have permitted assembled cell production at a rate of 10 sec/cell. Standards are being defined for module safety features. It is noted that construction of a pilot Si purification plant is essential to achieving the 1986 $0.70/W cost goals.

  7. Monocyte chemoattractant protein 1 (MCP-1) in temporal arteritis and polymyalgia rheumatica

    OpenAIRE

    Ellingsen, T.; Elling, P; Olson, A.; Elling, H; Baandrup, U; Matsushima, K.; Deleuran, B; Stengaard-Pederse..., K

    2000-01-01

    OBJECTIVE—To examine the localisation of monocyte chemoattractant protein 1 (MCP-1) in the inflamed vessel wall in temporal arteritis (TA) and to measure MCP-1 in plasma both in patients with TA and patients with polymyalgia rheumatica (PMR).
METHODS—By immunohistochemical techniques MCP-1 was localised to the vessel wall in patients with TA. In TA, PMR, and healthy controls MCP-1 was quantified by enzyme linked immunosorbent assay (ELISA) in plasma.
RESULTS—MCP-1 was localised to the majorit...

  8. 随机极性MCP-EBPSK传输性能%Transmission performance of MCP-EBPSK with random polar

    Institute of Scientific and Technical Information of China (English)

    靳一; 吴乐南; 冯熳; 邓蕾

    2012-01-01

    为提高随机极性的修正连续相位扩展二元相移键控(MCP-EBPSK)调制信号的传输性能,对比了AWGN信道上自适应门限判决、BP神经网络和支持向量机(SVM)判决3种解调方式的解调性能,并引入了RS码和规则LDPC码来进行改善.根据随机极性MCP-EBPSK调制原理和数字冲击滤波器特殊滤波机理,设计了基于自适应门限判决、BP神经网络和SVM的解调器.同时,在这3种解调方式性能均不佳时,对RS码和规则LDPC编码的随机极性MCP-EBPSK传输性能进行了仿真.仿真结果表明:在AWGN信道上,自适应门限判决、BP神经网络和SVM三种解调方式的解调性能相差不大;当采用自适应门限判决且误码率为10-4时,RS码和规则LDPC码的编码增益分别约为4 dB和7 dB.因此,引入信道编码可显著改善随机极性MCP-EBPSK的传输性能.%In order to improve the transmission performance of random polar and modified extended binary phase shift keying with continuous phase (MCP-EBPSK) modulated signal, the demodulation performance of the adaptive threshold discrimination, BP neural network, and support vector machine (SVM) in additive white Gaussian noise(AWGN) channel is compared, then Reed-Solomon (RS) code and regular low-density parity-check (LDPC) code are introduced. According to the principle of MCP-EBPSK with random polar and the special filtering mechanism of digital impacting filter, the demodulators are designed based on adaptive threshold discrimination, BP neural network, and SVM. Meanwhile, when the demodulation performance of these demodulators is poor, the RS and regular LDPC coded MCP-EBPSK with random polar is also simulated. Simulation results show that in AWGN channel, the demodulation performance of adaptive threshold discrimination, BP neural network and SVM is almost the same; when adaptive threshold discrimination is used and BER is 10-4, the coding gain of RS code and regular LDPC is about 4 dB and 7 dB, respectively

  9. Experimental study and clinical observation of minimum-contact plate in long bone fracture

    Institute of Scientific and Technical Information of China (English)

    YANG Xin-jian; FEI Jun; WANG Zheng-guo; YU Hong-jun; SUN Jun

    2005-01-01

    Objective: To sutdy the mechanical properties and the clinical results of minimum-contact plate in the treatment of fractures. Methods: Four-point bending and torsion tests were conducted to compare the new minimum contact plate (MCP) with dynamic compression plate (DCP) and limited contact dynamic compression plate (LC-DCP). The fracture healing time and growth of bony callus were observed in 29 cases of long bone fracture fixed with MCP to evaluate the advantages of this kind of plate. Results: The 29 patients who underwent MCP were followed up from 6 to 14 months. The average healing time for femoral, tibial and humeral fractures was 12, 13 and 10 weeks, respectively. All fractures were healed. No displacement of fracture, screw pullout, deformation or break of the plate were found. Conclusions: The bending stiffness of MCP is significantly greater than that of DCP and LC-DCP (P<0.05). MCP can protect the periosteal blood supply against avascular osseous necrosis and accelerate bone healing. It is a kind of reliable and effective plate in treatment of fractures.

  10. Effects of 1-MCP on Post-Harvest Physiology of Tomato

    Institute of Scientific and Technical Information of China (English)

    SUN Xi-sheng; WANG Zhi-hua; LI Zhi-qiang; ZHANG Zhi-yun; WANG Wen-hui

    2003-01-01

    Tomato (Lycopersicon esculentum cv. 402) was used to investigate the effects of 1-MCP (1-methylcyclopropene) treatment on ethylene production, respiration, vitamin C, chlorophyll, titratable acid,change of fruit color and rot. The results indicated that 1-MCP strongly inhibited ethylene production and respiration of tomato at very low concentration, delayed the incidence of climacteric peak of ethylene production and respiration. 1-MCP also delayed the decrease of vitamin C, chlorophyll and titratable acid during shelf life and storage significantly. Shelf and storage life of fruit treated with 1-MCP were extended at least 10 days at ambient (20 - 22℃ ) and 15 days at storage (9 - 11℃ ) temperature, respectively. Efficacy of 1-MCP on shelf and storage life was improved by increasing its concentration. After treatment of 1-MCP, rots were markedly lower than that of untreated fruit. 1-MCP treatment delayed the fruit color change.

  11. Image Processing Technology in the Motor Vehicle License Plate Recognition Technology Application%图像处理技术在机动车车牌自动识别技术中的应用

    Institute of Scientific and Technical Information of China (English)

    宁彬

    2013-01-01

    主要分析了图像处理技术在机动车车牌自动识别技术中的应用.按照车牌定位由彩色图转化到灰度图、车牌区域分割、车牌位置校正等步骤,对车牌字符的识别进行了分析,并对自动识别技术进行了改进.基于图像处理技术设计的机动车辆车牌自动识别系统,在保障交通顺畅运行方面发挥着巨大作用.从实际应用效果看图像处理技术在机动车车牌自动识别技术实际运用中效果良好,具有一定的推广价值.%The application of image processing technology in the motor vehicle license plate automatic identification technology was analyzed. In accordance with the license plate location transformed by the color chart to grayscale, license plate region segmentation, the license plate position correction step on the license plate character recognition, and automatic identification technology improvements. Motor vehicle car brand automatic identification system design based on the image processing technology, play a huge role in the protection of traffic running smoothly. From the effect of practical application of image processing technology in the motor vehicle license plate automatic identification technology to practical use in the good results, the promotional value.

  12. Environmental friendly crush-magnetic separation technology for recycling metal-plated plastics from end-of-life vehicles.

    Science.gov (United States)

    Xue, Mianqiang; Li, Jia; Xu, Zhenming

    2012-03-06

    Metal-plated plastics (MPP), which are important from the standpoint of aesthetics or even performance, are increasingly employed in a wide variety of situations in the automotive industry. Serious environmental problems will be caused if they are not treated appropriately. Therefore, recycling of MPP is an important subject not only for resource recycling but also for environmental protection. This work represents a novel attempt to deal with the MPP. A self-designed hammer crusher was used to liberate coatings from the plastic substrate. The size distribution of particles was analyzed and described by the Rosin-Rammler function model. The optimum retaining time of materials in the crusher is 3 min. By this time, the liberation rate of the materials can reach 87.3%. When the density of the suspension is 31,250 g/m(3), the performance of liberation is the best. Two-step magnetic separation was adopted to avoid excessive crushing and to guarantee the quality of products. Concerning both the separation efficiency and grade of products, the optimum rotational speed of the magnetic separator is 50-70 rpm. On the basis of the above studies about the liberating and separating behavior of the materials, a continuous recycling system (the technology of crush-magnetic separation) is developed. This recycling system provides a feasible method for recycling MPP efficiently, economically, and environmentally.

  13. MCP-1 expressed by osteoclasts stimulates osteoclastogenesis in an autocrine/paracrine manner

    Energy Technology Data Exchange (ETDEWEB)

    Miyamoto, Kana [Department of Orthopedic Surgery, Keio University School of Medicine, 35 Shinano-machi, Shinjuku-ku, Tokyo 160-8582 (Japan); Division of Orthopedic Research, Keio University School of Medicine, 35 Shinano-machi, Shinjuku-ku, Tokyo 160-8582 (Japan); Department of Cell Differentiation, The Sakaguchi Laboratory of Developmental Biology, Keio University School of Medicine, 35 Shinano-machi, Shinjuku-ku, Tokyo 160-8582 (Japan); Ninomiya, Ken [Department of Orthopedic Surgery, Keio University School of Medicine, 35 Shinano-machi, Shinjuku-ku, Tokyo 160-8582 (Japan); Department of Cell Differentiation, The Sakaguchi Laboratory of Developmental Biology, Keio University School of Medicine, 35 Shinano-machi, Shinjuku-ku, Tokyo 160-8582 (Japan); Sonoda, Koh-Hei [Department of Ophthalmology, Graduate School of Medical Sciences, Kyushu University, 3-1-1, Maidashi, Higashi-ku, Fukuoka, Fukuoka 812-8582 (Japan); Miyauchi, Yoshiteru; Hoshi, Hiroko [Department of Orthopedic Surgery, Keio University School of Medicine, 35 Shinano-machi, Shinjuku-ku, Tokyo 160-8582 (Japan); Division of Orthopedic Research, Keio University School of Medicine, 35 Shinano-machi, Shinjuku-ku, Tokyo 160-8582 (Japan); Iwasaki, Ryotaro [Division of Orthopedic Research, Keio University School of Medicine, 35 Shinano-machi, Shinjuku-ku, Tokyo 160-8582 (Japan); Department of Cell Differentiation, The Sakaguchi Laboratory of Developmental Biology, Keio University School of Medicine, 35 Shinano-machi, Shinjuku-ku, Tokyo 160-8582 (Japan); Department of Dentistry and Oral Surgery, Keio University School of Medicine, 35 Shinano-machi, Shinjuku-ku, Tokyo 160-8582 (Japan); Miyamoto, Hiroya [Department of Orthopedic Surgery, Keio University School of Medicine, 35 Shinano-machi, Shinjuku-ku, Tokyo 160-8582 (Japan); Division of Orthopedic Research, Keio University School of Medicine, 35 Shinano-machi, Shinjuku-ku, Tokyo 160-8582 (Japan); and others

    2009-06-05

    Monocyte chemoattractant protein-1 (MCP-1) is a chemokine that plays a critical role in the recruitment and activation of leukocytes. Here, we describe that multinuclear osteoclast formation was significantly inhibited in cells derived from MCP-1-deficient mice. MCP-1 has been implicated in the regulation of osteoclast cell-cell fusion; however defects of multinuclear osteoclast formation in the cells from mice deficient in DC-STAMP, a seven transmembrane receptor essential for osteoclast cell-cell fusion, was not rescued by recombinant MCP-1. The lack of MCP-1 in osteoclasts resulted in a down-regulation of DC-STAMP, NFATc1, and cathepsin K, all of which were highly expressed in normal osteoclasts, suggesting that osteoclast differentiation was inhibited in MCP-1-deficient cells. MCP-1 alone did not induce osteoclastogenesis, however, the inhibition of osteoclastogenesis in MCP-1-deficient cells was restored by addition of recombinant MCP-1, indicating that osteoclastogenesis was regulated in an autocrine/paracrine manner by MCP-1 under the stimulation of RANKL in osteoclasts.

  14. Capacitively coupled pickup in MCP-based photodetectors using a conductive metallic anode

    Science.gov (United States)

    Angelico, E.; Seiss, T.; Adams, B.; Elagin, A.; Frisch, H.; Spieglan, E.

    2017-02-01

    We have designed and tested a robust 20×20 cm2 thin metal film internal anode capacitively coupled to an external array of signal pads or micro-strips for use in fast microchannel plate photodetectors. The internal anode, in this case a 10 nm-thick NiCr film deposited on a 96% pure Al2O3 3 mm-thick ceramic plate and connected to HV ground, provides the return path for the electron cascade charge. The multi-channel pickup array consists of a printed-circuit card or glass plate with metal signal pickups on one side and the signal ground plane on the other. The pickup can be put in close proximity to the bottom outer surface of the sealed photodetector, with no electrical connections through the photodetector hermetic vacuum package other than a single ground connection to the internal anode. Two pickup patterns were tested using a small commercial MCP-PMT as the signal source: 1) parallel 50 Ω 25-cm-long micro-strips with an analog bandwidth of 1.5 GHz, and 2) a 20×20 cm2 array of 2-dimensional square 'pads' with sides of 1.27 cm or 2.54 cm. The rise-time of the fast input pulse is maintained for both pickup patterns. For the pad pattern, we observe 80% of the directly coupled amplitude. For the strip pattern we measure 34% of the directly coupled amplitude on the central strip of a broadened signal. The physical decoupling of the photodetector from the pickup pattern allows easy customization for different applications while maintaining high analog bandwidth.

  15. Application of Micro-channel Plate (MCP) in Magnetic Spectra Meter of Hot Electrons

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The interaction between ultra-short pulse laser and solid target generates hot electrons. Owing to lowenergy of laser (10 J), there are not so many electrons. In order to improve resoling power of spectra meter,the solid angle of spectra meter must be very little. So the number of entering into the meter is very few.

  16. Radiation monitoring using imaging plate technology: A case study of leaves affected by the Chernobyl nuclear power plant and JCO criticality accidents

    Directory of Open Access Journals (Sweden)

    Kimura Shinzo

    2006-01-01

    Full Text Available This paper describes the use of a photostimulable phosphor screen imaging technique to detect radioactive contamination in the leaves of wormwood (Artemisia vulgaris L and fern (Dryopteris filix-max CL. Schoff plants affected by the Chernobyl nuclear power plant accident. The imaging plate technology is well known for many striking performances in two-dimensional radiation detection. Since imaging plate comprises an integrated detection system, it has been extensively applied to surface contamination distribution studies. In this study, plant samples were collected from high- and low-contaminated areas of Ukraine and Belarus, which were affected due to the Chernobyl accident and exposed to imaging technique. Samples from the highly contaminated areas revealed the highest photo-stimulated luminescence on the imaging plate. Moreover, the radio nuclides detected in the leaves by gamma and beta ray spectroscopy were 137Cs and 90Sr, respectively. Additionally, in order to assess contamination, a comparison was also made with leaves of plants affected during the JCO criticality accident in Japan. Based on the results obtained, the importance of imaging plate technology in environmental radiation monitoring has been suggested.

  17. Development of Heat Exchanger Plate Based on Digital Manufacture Technology%基于数字制造技术的热交换器板片开发

    Institute of Scientific and Technical Information of China (English)

    王新; 胡国栋; 常春梅; 赵亮; 王忠; 殷建刚; 姚小毅

    2012-01-01

    热交换器板片是换热器中的主要换热元件,采用传统板片开发方法的模具返修率较高,尤其是超大型板片的开发.数字制造技术充分利用了计算技术的优势,将传统方法中的样板试制、模具改造两个环节集成为数字制造,使模具的返修变为几何模型的修改,从而极大提高了成形板片的冲压质量和使用性能.%Heat exchanger plate is the main heat-exchange components in the heat exchanger. The method of traditional development plate of the molds is more likely to repair, especially in the development of super large plate. The digital manufacturing technology made full use of the advantages of the computing technology, and integrated the traditional method of making samples and repairing molds are more likely to the digital manufacturing process, and transformed repairing mould to modifying geometric model, thus greatly increase quality and performance of the stamping plate.

  18. Transmission characteristics of x-ray in MCP collimator in parallel structure

    Science.gov (United States)

    Qin, Xulei; Li, Ye; Chen, Weijun

    2016-11-01

    In order to improve the imaging quality of X-ray and reduce the effects of X-ray and scatter line on image, the adoption of X-ray collimator is the most effective method. MCP collimator in parallel structure can effectively reduce the ratio of X-ray and scatter line to reach on image plane, and reduce the atomization degree of images, so as to improve the image contrast. Through the establishment first-order radiation transmittance model of MCP collimator, test the performance of MCP collimator, it is prove that the MCP collimator can be used in the imaging system that consists of proximity of X-ray image intensifier, first-order radiation transmittance calculation formula of MCP absorption type collimator in parallel structure is reduced, obtain the transmittance distribution non cosine curve distribution of MCP collimator through calculating.

  19. IP-10, MCP-1, MCP-2, MCP-3, and IL-1RA hold promise as biomarkers for infection with M. tuberculosis in a whole blood based T-cell assay

    DEFF Research Database (Denmark)

    Ruhwald, Morten; Bjerregaard-Andersen, Morten; Rabna, Paulo

    2009-01-01

    for in-vitro diagnosis of tuberculosis - MCP-1, MCP-3 and IL-1RA - with the current established biomarker IFN-gamma and the newly described IP-10 and MCP-2. METHODS: Whole blood from 8 patents with active tuberculosis and from 7 healthy controls was stimulated with M. tuberculosis specific antigens......BACKGROUND: IFN-gamma responses to M. tuberculosis antigens are used as in-vitro diagnostic tests for tuberculosis infection. The tests are highly specific but sensitivity may be impaired due to immuno-suppression. The objective of this small exploratory study was to compare three novel biomarkers...... and mitogen in the Quantiferon In Tube test tubes. Levels of biomarkers were measured using Luminex and ELISA (IFN-gamma). RESULTS: We found all five new biomarkers were expressed in significantly higher concentrations compared to IFN-gamma. IP-10 and MCP-3 levels in the un-stimulated samples were higher...

  20. Microchannel plate special nuclear materials sensor

    Energy Technology Data Exchange (ETDEWEB)

    Feller, W.B., E-mail: bfeller@novascientific.com [Nova Scientific Inc., 10 Picker Road, Sturbridge, MA 01566 (United States); White, P.L.; White, P.B. [Nova Scientific Inc., 10 Picker Road, Sturbridge, MA 01566 (United States); Siegmund, O.H.W.; Martin, A.P.; Vallerga, J.V. [Sensor Sciences, 3333 Vincent Road, Pleasant Hill, CA 94523 (United States)

    2011-10-01

    Nova Scientific Inc., is developing for the Domestic Nuclear Detection Office (DNDO SBIR no. HSHQDC-08-C-00190), a solid-state, high-efficiency neutron detection alternative to {sup 3}He gas tubes, using neutron-sensitive microchannel plates (MCPs) containing {sup 10}B and/or Gd. This work directly supports DNDO development of technologies designed to detect and interdict nuclear weapons or illicit nuclear materials. Neutron-sensitized MCPs have been shown theoretically and more recently experimentally, to be capable of thermal neutron detection efficiencies equivalent to {sup 3}He gas tubes. Although typical solid-state neutron detectors typically have an intrinsic gamma sensitivity orders of magnitude higher than that of {sup 3}He gas detectors, we dramatically reduce gamma sensitivity by combining a novel electronic coincidence rejection scheme, employing a separate but enveloping gamma scintillator. This has already resulted in a measured gamma rejection ratio equal to a small {sup 3}He tube, without in principle sacrificing neutron detection efficiency. Ongoing improvements to the MCP performance as well as the coincidence counting geometry will be described. Repeated testing and validation with a {sup 252}Cf source has been underway throughout the Phase II SBIR program, with ongoing comparisons to a small commercial {sup 3}He gas tube. Finally, further component improvements and efforts toward integration maturity are underway, with the goal of establishing functional prototypes for SNM field testing.

  1. Effective Evaluation of the Noise Factor of Microchannel Plate

    Directory of Open Access Journals (Sweden)

    Honggang Wang

    2015-01-01

    Full Text Available To improve the noise performance of microchannel plate (MCP, we have presented a method using the sine random signals with Poisson distribution as the noise-excitation for electron source. By using this method, the effective evaluation of noise characteristics of MCP has been implemented through measuring and analyzing its noise factor. The results have demonstrated that the noise factor of filmed MCP is lower than 1.8. Additionally, as the open area ratio and the input electron energy are 72% and 400 eV, respectively, the noise characteristics of unfilmed MCP are improved evidently. Moreover, larger open area ratio, higher input electron energy, and higher voltage across the MCP all can reduce effectively the noise factor within a certain range. Meanwhile, the ion barrier film extends the life of image tube but at the cost of an increased noise factor. Therefore, it is necessary that a compromise between the optimum thickness of ion barrier film, open area ratio, input electron energy, and voltage across the MCP must be reached.

  2. MCP-1 binds to oxidized LDL and is carried by lipoprotein(a) in human plasma

    Science.gov (United States)

    Wiesner, Philipp; Tafelmeier, Maria; Chittka, Dominik; Choi, Soo-Ho; Zhang, Li; Byun, Young Sup; Almazan, Felicidad; Yang, Xiaohong; Iqbal, Navaid; Chowdhury, Punam; Maisel, Alan; Witztum, Joseph L.; Handel, Tracy M.; Tsimikas, Sotirios; Miller, Yury I.

    2013-01-01

    Lipoprotein oxidation plays an important role in pathogenesis of atherosclerosis. Oxidized low density lipoprotein (OxLDL) induces profound inflammatory responses in vascular cells, such as production of monocyte chemoattractant protein-1 (MCP-1) [chemokine (C-C motif) ligand 2], a key chemokine in the initiation and progression of vascular inflammation. Here we demonstrate that OxLDL also binds MCP-1 and that the OxLDL-bound MCP-1 retains its ability to recruit monocytes. A human MCP-1 mutant in which basic amino acids Arg-18 and Lys-19 were replaced with Ala did not bind to OxLDL. The MCP-1 binding to OxLDL was inhibited by the monoclonal antibody E06, which binds oxidized phospholipids (OxPLs) in OxLDL. Because OxPLs are carried by lipoprotein(a) [Lp(a)] in human plasma, we tested to determine whether Lp(a) binds MCP-1. Recombinant wild-type but not mutant MCP-1 added to human plasma bound to Lp(a), and its binding was inhibited by E06. Lp(a) captured from human plasma contained MCP-1 and the Lp(a)-associated endogenous MCP-1 induced monocyte migration. These results demonstrate that OxLDL and Lp(a) bind MCP-1 in vitro and in vivo and that OxPLs are major determinants of the MCP-1 binding. The association of MCP-1 with OxLDL and Lp(a) may play a role in modulating monocyte trafficking during atherogenesis. PMID:23667177

  3. MCP-1 promotes mural cell recruitment during angiogenesis in the aortic ring model.

    Science.gov (United States)

    Aplin, Alfred C; Fogel, Eric; Nicosia, Roberto F

    2010-09-01

    Rings of rat or mouse aorta embedded in collagen gels produce angiogenic outgrowths in response to the injury of the dissection procedure. Aortic outgrowths are composed of branching endothelial tubes and surrounding mural cells. Mural cells emerge following endothelial sprouting and gradually increase during the maturation of the neovessels. Treatment of aortic cultures with angiopoietin-1 (Ang-1), an angiogenic factor implicated in vascular maturation and remodeling, stimulates the mural cell recruitment process. Ang-1 induces expression of many cytokines and chemokines including monocyte chemotactic protein-1 (MCP-1). Inhibition of p38 MAP kinase, a signaling molecule required for mural cell recruitment, blocks Ang1-induced MCP-1 expression. Recombinant MCP-1 dose-dependently increases mural cell number while an anti-MCP-1 blocking antibody reduces it. In addition, antibody mediated neutralization of MCP-1 abrogates the stimulatory effect of Ang-1 on mural cell recruitment. Aortic rings from genetically modified mice deficient in MCP-1 or its receptor CCR2 have fewer mural cells than controls. MCP-1 deficiency also impairs the mural cell recruitment activity of Ang-1. Our studies indicate that spontaneous and Ang1-induced mural cell recruitment in the aortic ring of model of angiogenesis are in part mediated by MCP-1. These results implicate MCP-1 as one of the mediators of mural cell recruitment in the aortic ring model, and suggest that chemokine pathways may contribute to the assembly of the vessel wall during the angiogenesis response to injury.

  4. 三凸片成形工艺及模具设计%The Forming Technology Analysis and Mould Design for Three Bulges Plate

    Institute of Scientific and Technical Information of China (English)

    刘晓冰

    2001-01-01

    This paper has introduced the forming technology, mouldstructure, and working principle of composite die for three bulges plate. The advantages of the die are rational design, good reliablity and high economic protential.%介绍了三凸片成形工艺及冲压模具的结构、工作原理。该模具设计合理,可靠性好,经济效益特别显著。

  5. Antiproton, positron, and electron imaging with a microchannel plate/phosphor detector

    Science.gov (United States)

    Andresen, G. B.; Bertsche, W.; Bowe, P. D.; Bray, C. C.; Butler, E.; Cesar, C. L.; Chapman, S.; Charlton, M.; El Nasr, S. Seif; Fajans, J.; Fujiwara, M. C.; Gill, D. R.; Hangst, J. S.; Hardy, W. N.; Hayano, R. S.; Hayden, M. E.; Humphries, A. J.; Hydomako, R.; Jørgensen, L. V.; Kerrigan, S. J.; Kurchaninov, L.; Lambo, R.; Madsen, N.; Nolan, P.; Olchanski, K.; Olin, A.; Povilus, A. P.; Pusa, P.; Sarid, E.; Silveira, D. M.; Storey, J. W.; Thompson, R. I.; van der Werf, D. P.; Yamazaki, Y.; Alpha Collaboration

    2009-12-01

    A microchannel plate (MCP)/phosphor screen assembly has been used to destructively measure the radial profile of cold, confined antiprotons, electrons, and positrons in the ALPHA experiment, with the goal of using these trapped particles for antihydrogen creation and confinement. The response of the MCP to low energy (10-200 eV, <1 eV spread) antiproton extractions is compared to that of electrons and positrons.

  6. Direct tests of micro channel plates as the active element of a new shower maximum detector

    Energy Technology Data Exchange (ETDEWEB)

    Ronzhin, A., E-mail: ronzhin@fnal.gov [Fermilab, Batavia, IL 60510 (United States); Los, S.; Ramberg, E. [Fermilab, Batavia, IL 60510 (United States); Apresyan, A.; Xie, S.; Spiropulu, M. [California Institute of Technology, Pasadena, CA (United States); Kim, H. [University of Chicago, Chicago, IL 60637 (United States)

    2015-09-21

    We continue the study of micro channel plates (MCP) as the active element of a shower maximum (SM) detector. We present below test beam results obtained with MCPs detecting directly secondary particles of an electromagnetic shower. The MCP efficiency to shower particles is close to 100%. The time resolution obtained for this new type of the SM detector is at the level of 40 ps.

  7. Detection efficiency evaluation for a large area neutron sensitive microchannel plate detector

    CERN Document Server

    Wang, Yiming; Liu, Ren

    2016-01-01

    In this paper, the detection efficiency of a large area neutron sensitive microchannel plate detector has been evaluated. A 6LiF/ZnS detector was employed as the benchmark detector, the TOF spectra of these two detectors were simultaneously measured and the energy spectra were then deduced to calculate the detection efficiency curve of the nMCP detector. Tests show the detection efficiency@25.3 meV thermal neutron is 34% for this nMCP detector.

  8. Antiproton, positron, and electron imaging with a microchannel plate/phosphor detector

    CERN Document Server

    Andresen, G B; Bowe, P D; Bray, C; Butler, E; Cesar, C L; Chapman, S; Charlton, M; Fajans, J; Fujiwara, M C; Gill, D R; Hangst, J S; Hardy, W N; Hayano, R S; Hayden, M E; Humphries, A J; Hydomako, R; Jørgensen, L V; Kerrigan, S J; Kurchaninov, L; Lambo, R; Madsen, N; Nolan, P; Olchanski, K; Olin, A; Povilus, A; Pusa, P; Sarid, E; Seif El Nasr, S; Silveira, D M; Storey, J W; Thompson, R I; van der Werf, D P; Yamazaki, Y

    2009-01-01

    A microchannel plate (MCP)/phosphor screen assembly has been used to destructively measure the radial profile of cold, confined antiprotons, electrons, and positrons in the ALPHA experiment, with the goal of using these trapped particles for antihydrogen creation and confinement. The response of the MCP to low energy (10-200 eV, <1 eV spread) antiproton extractions is compared to that of electrons and positrons.

  9. Project of Economically Profitable Technological Process of Production of Rotor and Stator Plates of Inductive Position Sensor by Blanking and Roll Bending

    Directory of Open Access Journals (Sweden)

    Radek ČADA

    2013-12-01

    Full Text Available Paper concerns innovation of production of rotor and stator plates of inductive position sensors which are used at automatization of production processes. Authors analyse possibility of efficiency improvement of production of these devices in joint-stock company TES VSETÍN and suggest concrete solving of new production technology. Composition of production line for blanking and roll bending of rotor and stator plates of inductive position sensor from individual technological devices was suggested: decoiler, straightening device, actuating belt feeder, pneumatic shears with inclined tools, belt conveyer and four cylinders bending rolls. Construction of production line was projected in order to its operation can be secured by one production workman, which controls and chooses operation of CNC programme, takes separate roll bended rotor and stator plates of inductive position sensor from bending rolls and according to required technological procedure he composes them to rotor and stator complexes. Construction of production line was projected so that it is possible to move it by crane without necessity to dismantle and subsequently to put together and adjust the line.

  10. Enforced effect of tk-MCP-1 fusion gene in ovarian cancer

    Directory of Open Access Journals (Sweden)

    Hong Shuhui

    2012-09-01

    Full Text Available Abstract Objective The efficiency of HSV-tk/GCV system is not high because of insufficient gene transfer and incompletely initiative of host antineoplastic potency. The present study was designed to assess the antitumor efficacy of tk-MCP-1 on ovarian cancer in vitro and vivo. Methods A novel bicistronic expression system can help to improve the expression level of a gene in a stable manner. pLXSN/tk-MCP-1 co-expressing tk and MCP-1 genes was constructed using a pLXSN retroviral vector and an internal ribosome entry site sequence by restriction enzyme. Western blot was performed to determine tk and MCP-1 expression in the infected SKOV3. The GCV-sensitively tumoricidal activities of SKOV3/tk-MCP-1 with or without monocytes were compared to those of SKOV3 expressing HSV-tk or MCP-1. We investigated the growth of subcutaneous tumors in SCID mice immuno-reconstituted, and evaluated the antitumor effect of MCP-1 in conjunction with suicide gene. Results The significant GCV-sensitively tumoricidal activity of pLXSN/tk-MCP-1 was observed when compared with those of pLXSN/tk, pLXSN/MCP-1 and pLXSN/neo, especially when monocytes were added. The growth of subcutaneous tumors in SCID mice immuno-reconstituted was markedly suppressed by co-delivery of HSV-tk and MCP-1 genes, and the enhanced antitumor effect was associated with the recruitment of monocytes. Conclusion These results demonstrated pLXSN/tk-MCP-1 presented an enhanced antitumor effects on ovarian cancer by orchestration of immune responses.

  11. Detection efficiency, spatial and timing resolution of thermal and cold neutron counting MCP detectors

    Science.gov (United States)

    Tremsin, A. S.; McPhate, J. B.; Vallerga, J. V.; Siegmund, O. H. W.; Hull, J. S.; Feller, W. B.; Lehmann, E.

    2009-06-01

    Neutron counting detectors with boron or gadolinium doped microchannel plates (MCPs) have very high detection efficiency, spatial and temporal resolution, and have a very low readout noise. In this paper we present the results of both theoretical predictions and experimental evaluations of detection efficiency and spatial resolution measured at cold and thermal neutron beamlines. The quantum detection efficiency of a detector (not fully optimized) was measured to be 43% and 16% for the cold and thermal beamlines, respectively. The experiments also demonstrate that the spatial resolution can be better than 15 μm—highest achievable with the particular MCP pore dimension used in the experiment, although more electronics development is required in order to increase the counting rate capabilities of those <15 μm resolution devices. The timing accuracy of neutron detection is on the scale of few μs and is limited by the neutron absorption depth in the detector. The good agreement between the predicted and measured performance allows the optimization of the detector parameters in order to achieve the highest spatial resolution and detection efficiency in future devices.

  12. Optical and UV Sensing Sealed Tube Microchannel Plate Imaging Detectors with High Time Resolution

    Science.gov (United States)

    Siegmund, O.; Vallerga, J.; Tremsin, A.; Hull, J.; Elam, J.; Mane, A.

    2014-09-01

    Microchannel plate (MCP) based imaging, photon time tagging detector sealed tube schemes have a unique set of operational features that enable high time resolution astronomical and remote sensing applications to be addressed. New detectors using the cross strip (XS), cross delay line (XDL), or stripline anode readouts, a wide range of photocathode types, and advanced MCP technologies have been implemented to improve many performance characteristics. A variety of sealed tubes have been developed including 18mm XS readout devices with GaAs and SuperGenII photocathodes, 25mm XDL readout devices with SuperGenII and GaN photocathodes, and 20 x 20 cm sealed tubes with bialkali photocathodes and strip line readout. One key technology that has just become viable is the ability to make MCPs using atomic layer deposition (ALD) techniques. This employs nanofabrication of the active layers of an MCP on a microcapillary array. This technique opens new performance opportunities, including, very large MCP areas (>20cm), very low intrinsic background, lower radiation induced background, much longer overall lifetime and gain stability, and markedly lower outgassing which can improve the sealed tube lifetime and ease of fabrication. The XS readout has been implemented in formats of 22mm, 50mm and 100mm, and uses MCP charge signals detected on two orthogonal layers of conductive fingers to encode event X-Y positions. We have achieved spatial resolution XS detectors better than 25 microns FWHM, with good image linearity while at low gain (5 MHz with ~12% dead time and event timing accuracy of ~100ps. XDL sealed tubes in 25mm format demonstrate ~40 micron spatial resolution at up to ~2 MHz event rates, and have been developed with SupergenII visible regime photocathodes. The XDL tubes also achieve ~100 ps time resolution. Most recently ALD MCPs with an opaque GaN photocathode (100-350nm range) on the MCP surface has been demonstrated in a sealed tube configuration. These ALD MCPs show

  13. Dead-time effects in microchannel-plate imaging detectors

    Science.gov (United States)

    Zombeck, Martin V.; Fraser, George W.

    1991-01-01

    The observed counting rates of microchannel plate (MCP) based detectors for high resolution observations of celestial EUV and X-ray sources vary over many orders of magnitude; the counting capability of an individual channel, however, is not high, and is associated with dead-times ranging from 0.1 msec to 1 sec. The dead-time increases with the area illuminated; attention is presently given to laboratory determinations of the count rate characteristics of a MCP detector as a function of illuminated area, and a model is developed for these results' use in the interpretation of space observations.

  14. Evaluating the potential of IP-10 and MCP-2 as biomarkers for the diagnosis of TB

    DEFF Research Database (Denmark)

    Ruhwald, Morten; Bodmer, T; Maier, C

    2008-01-01

    The aim of the study was to evaluate the potential of diagnostic tests based on IP-10 and MCP-2, and compare the performance with the Quantiferon-Gold In-Tube (QFT-IT) test.IP-10 and MCP-2 were determined in supernatants from whole blood stimulated with M.tuberculosis-specific antigens. Samples...

  15. The R&D of the 20 in. MCP-PMTs for JUNO

    Science.gov (United States)

    Chang, Yaping; Huang, Guorui; Heng, Yuekun; Li, Dong; Liu, Huilin; Liu, Shulin; Li, Weihua; Ning, Zhe; Qi, Ming; Qian, Sen; Sun, Jianning; Si, Shuguang; Tian, Jinshou; Wang, Xingchao; Wang, Xing; Wang, Yifang; Wei, Yonglin; Wang, Wenwen; Xia, Jingkai; Xin, Liwei; Zhao, Tianchi

    2016-07-01

    A new concept of large area photomultiplier based on MCPs was conceived for JUNO by the scientists in IHEP, and with the collaborative work of the MCP-PMT collaboration in China, 8 in. and 20 in. prototypes were produced. Test results show that this type of MCP-PMT can have good SPE performance as the traditional dynode type PMTs.

  16. THE EFFECT OF 1-MCP IN MAINTAINING THE QUALITY OF TOMATO SLICES

    Directory of Open Access Journals (Sweden)

    Darwin H. Pangaribuan1

    2010-06-01

    Full Text Available Maintenance of quality traits is important during storage of fresh-cut produce. Changes in firmness, in tomato for instance, are ethylene-mediated. The objective of this study was to determine the suitability of the ethylene antagonist 1-MCP in maintaining the quality of tomato slices. Fruits of tomato cv. ‘Revolution’ were harvested at the ‘pink’ stage of maturity, treated with 1 L.L-1 1-MCP for 12 hours at 20 ºC, and sliced. Slices were stored as vertical stacks in closed plastic containers at 5 C for up to 10 days. Exposure of intact tomatoes to 1-MCP reduced ethylene production and respiration rate in slices, and produced firmer slices than when intact tomatoes were treated without 1-MCP. When intact tomatoes, at the ‘pink’ maturity stage were treated with several concentrations at 1-MCP (0.1, 1.0 or 10.0 L.L-1 at 20 C for 12 h, 1-MCP reduced both ethylene production and the respiration rate, delayed softening of the pericarp and inhibited loss in acidity when compared with slices from fruit not treated with 1-MCP. The most effective concentration of 1-MCP for inhibiting the ethylene-induced softening of tomato slices was 1 L.L-1.

  17. Thomson spectrometer-microchannel plate assembly calibration for MeV-range positive and negative ions, and neutral atoms

    Energy Technology Data Exchange (ETDEWEB)

    Prasad, R. [Centre for Plasma Physics, School of Mathematics and Physics, The Queen' s University of Belfast, Belfast BT7 1NN (United Kingdom); Abicht, F.; Braenzel, J.; Priebe, G.; Schnuerer, M. [Max Born Institute for Nonlinear Optics and Short Pulse Spectroscopy, 12489 Berlin (Germany); Borghesi, M.; Ter-Avetisyan, S. [Centre for Plasma Physics, School of Mathematics and Physics, The Queen' s University of Belfast, Belfast BT7 1NN (United Kingdom); ELI-Beamlines Project, Institute of Physics of the ASCR, Na Slovance 2, 18221 Prague (Czech Republic); Nickles, P. V. [WCU Department of Nanobio Materials and Electronics, GIST, Gwangju 500-712 (Korea, Republic of)

    2013-05-15

    We report on the absolute calibration of a microchannel plate (MCP) detector, used in conjunction with a Thomson parabola spectrometer. The calibration delivers the relation between a registered count numbers in the CCD camera (on which the MCP phosphor screen is imaged) and the number of ions incident on MCP. The particle response of the MCP is evaluated for positive, negative, and neutral particles at energies below 1 MeV. As the response of MCP depends on the energy and the species of the ions, the calibration is fundamental for the correct interpretation of the experimental results. The calibration method and arrangement exploits the unique emission symmetry of a specific source of fast ions and atoms driven by a high power laser.

  18. Study of the effects of 1-MCP to blueberry under cold storage

    Science.gov (United States)

    Tao, Shenchen; Chu, Huailiang; Chen, Xiaomin; Yuan, Huwei; Qiu, Lingling; Zhao, Liang; Yan, Daoliang; Zheng, Bingsong

    2017-04-01

    Blueberry is one of the thinnest exocarp fruits in the world, which is difficult to keep fresh due to the special structure of its skin. 1-Methlcyclopropene (1-MCP) is able to combine with ethylene(ETH) receptor. In this study we investigated the effect of 1-MCP on rotting rate, weight loss ratio, soluble sugar content, titratable acid content, antioxidant enzyme activities and malondialdehyde (MDA) content in blueberry (Vaccinium corymbosun ‘O Neal’ and ‘North Road’) under cold storage. 1-MCP reduced the rotting rate, weight loss ratio and MDA content, while keeping high-leveled stability in antioxidant enzyme activities, soluble sugar content and titratable acid content. These results showed the role of 1-MCP in alleviating the negative effects of blueberry and suggested that 1-MCP could be used as a preservative for keeping thin exocarp fruit in fresh.

  19. The MCP-8 gene and its possible association with resistance to Streptococcus agalactiae in tilapia.

    Science.gov (United States)

    Fu, Gui Hong; Wan, Zi Yi; Xia, Jun Hong; Liu, Feng; Liu, Xiao Jun; Yue, Gen Hua

    2014-09-01

    Mast cell proteases play an important role in the regulation of the immune response. We identified the cDNA of the mast cell protease 8 (MCP-8) gene and analyzed its genomic structure in tilapia. The ORF of the MCP-8 was 768 bp, encoding 255 amino acids. Quantitative real-time PCR revealed that the MCP-8 gene was expressed predominantly in spleen, moderately in liver, blood, brain, gill, intestine, skin, and weakly expressed in kidney, muscle and eye. After a challenge with Streptococcus agalactiae, the gene was induced significantly (p 0.05). These results suggest that the MCP-8 gene play an important role in the resistance to S. agalactiae in tilapia. The SNP markers in the MCP-8 gene associated with the resistance to the bacterial pathogen may facilitate selection of tilapia resistant to the bacterial disease.

  20. Electron optics design of an 8-in. spherical MCP-PMT

    Science.gov (United States)

    Chen, Ping; Tian, Jinshou; Qian, Sen; Zhao, Tianchi; Liu, Hulin; Wei, Yonglin; Sai, Xiaofeng; He, Jianping; Wang, Xing; Lu, Yu; Chen, Lin; Guo, Lehui; Pei, Chengquan; Hui, Dandan

    2017-03-01

    This paper discusses the electron optical system of an 8-in. spherical MCP-PMT. The MCP assembly, the supporting pole and the supply voltages are carefully designed to optimize the photoelectron collection efficiency and the transit time spread. Coating the MCP nickel-chromium electrode with an additional high secondary emission material is employed to make a breakthrough on the collection efficiency. With the simulation software CST, the Finite Integration method and the Monte Carlo method are combined to evaluate the collection efficiency, the time properties and the Earth's magnetic field effects. Simulation results show that the photocathode active solid angle is over 3.5 πsr, the average collection efficiency can exceed 95% with the coated MCP and the mean transit time spread is 2.2 ns for a typical electric potential of 500 V applied between the photocathode and the MCP input facet. The prototype and the measured single photoelectron spectrum are also presented.

  1. 2Kx2K resolution element photon counting MCP sensor with >200 kHz event rate capability

    CERN Document Server

    Vallerga, J V

    2000-01-01

    Siegmund Scientific undertook a NASA Small Business Innovative Research (SBIR) contract to develop a versatile, high-performance photon (or particle) counting detector combining recent technical advances in all aspects of Microchannel Plate (MCP) detector development in a low cost, commercially viable package that can support a variety of applications. The detector concept consists of a set of MCPs whose output electron pulses are read out with a crossed delay line (XDL) anode and associated high-speed event encoding electronics. The delay line anode allows high-resolution photon event centroiding at very high event rates and can be scaled to large formats (>40 mm) while maintaining good linearity and high temporal stability. The optimal sensitivity wavelength range is determined by the choice of opaque photocathodes. Specific achievements included: spatial resolution of 200 000 events s sup - sup 1; local rates of >100 events s sup - sup 1 per resolution element; event timing of <1 ns; and low background ...

  2. Technology of Gold-Plated Cupreous Shell Encapsulation%Cu镀Au腔体气密性封装工艺研究

    Institute of Scientific and Technical Information of China (English)

    刘远志; 卢肖

    2011-01-01

    Gold-plated cupreous shell is one of the most common packaging techniques for microwave devices.Now the encapsulation of gold-plated cupreous shell has become the bottleneck of industrial engineering,and greatly limits the reliability and useful life of microwave devices.The encapsulation technology of gold-plated cupreous shell which is widely used for digital control attenuator is researched.The possible processing approaches have been compared with each other.After the comparison between laser welding and vacuum soldering,the hole encapsulation is proposed as a novel method.The encapsulation of gold-plated cupreous shell is realized by this low-cost engineering technology.%Cu镀Au腔体是微波器件常用封装载体之一。在目前应用中,Cu镀Au腔体微波器件的气密性封装一直是工程化技术难题,大幅影响了微波器件的可靠性和使用寿命。对基于Cu镀Au腔体的微波器件进行了气密性封装研究,探讨了Cu镀Au腔体实现气密性封装可能的工艺路线。通过比较激光封焊和真空钎焊等传统气密性封装工艺方法,提出了"小孔密封"的全新工艺路径,实现了Cu镀Au腔体气密性封装,为Cu镀Au腔体微波器件气密性封装提供了一种低成本的工程化解决方案。

  3. 激光扫描技术在钢板宽度检测中的应用%Application of Laser Scanning Technology in Steel Plate Width Inspection

    Institute of Scientific and Technical Information of China (English)

    姜占平

    2014-01-01

    The computer digital image processing technology was used for steel plate width inspection in real-time. In the hard-ware structure aspect,the dual CCD cameras and the optical imaging laser scanning measurement technology were employed to improve the inspection accuracy of the system. According to the CCD imaging principles and similar triangle theorems,the computer model for width changing caused by steel plate width changing and steel plate edge floating was derived. The laser sub-line method that using blocking plate in the laser projected way was put forward to determine the measurement errors caused by steel plate edge floating,and the steel plate width was corrected according to the results of measurement. At the same time,through the analysis of CCD camera laser stripe optimal imaging method,the experimental calibration was implement for the system. The result manifests that the inspection ac-curacy of the system can meet the practical application requirements well.%采用计算机数字图像处理技术对钢板宽度进行实时检测。在硬件结构上,采用双CCD感光器加激光线辅助光源扫描检测技术,提高系统检测精度。根据CCD成像原理及三角形相似定理,对因钢板宽度变化及钢板边缘上浮所引起的宽度变化计算模型进行了推导,提出了采用激光线遮挡板分线法来判定钢板边缘上浮所引起的测量误差,并根据误差测量结果,对钢板宽度进行了修正;同时,通过分析CCD激光线条最佳成像方法对系统进行了试验标定。结果表明,该系统的测量精度能满足实际生产需求。

  4. Research on Precaution and Detection Technology for Flow Blockage of Plate-type Fuel Element in Research Reactors

    Institute of Scientific and Technical Information of China (English)

    DING; Li; QIAO; Ya-xin; ZHANG; Nian-peng; LUO; Bei-bei; HUA; Xiao; JIA; Shu-jie; YAN; Hui-yang

    2013-01-01

    The main aim of this study is to offer the technical support for safety operation and management of research reactors using plate-type fuel assemblies in China,which is performed from analysis of precaution measures for flow blockage and detection methods of accidents.Study shows that most accidents were induced by in-core foreign objects and the swelling of fuel

  5. Microchannel plate modal gain variations with temperature

    Science.gov (United States)

    Slater, David C.; Timothy, J. G.

    1993-01-01

    Measurements of the modal gain of two high-gain curved-channel microchannel plates (MCPs) at various operating temperatures are presented. Both MCPs were fabricated from the Long Life glass with 12-micron diam channels on 15-micron centers. The modal gain was found to decrease with increasing temperature at a rate of -0.1 percent C. This reduction of gain with temperature is attributed primarily to an axial temperature gradient along each MCP channel creating a nonuniform electric field within the channel that lowers the effective output gain. A lowering of the secondary electron yield resulting from increased phonon scattering of secondary electrons released within the walls of the MCP channels was assessed, but was found to have a negligible contribution to the drop in gain with temperature.

  6. Nanosecond Gating Properties Of Proximity-Focused Microchannel-Plate Image Intensifiers

    Science.gov (United States)

    King, N. S.; Yates, G. J.; Jaramillo, S. A.; Ogle, J. W.; Detch, J. L.

    1981-12-01

    Some fundamental properties of 18-mm-diam gated proximity-focussed microchannel-plate (MCP) image intensifiers used as fast image shutters in the 1 to 10 ns range have been identified and studied. Light pulses (≍ 5-ps-wide) from a modelocked dye laser optically sample the gated MCP. Shuttering is achieved by applying a forward-biasing electrical gate pulse to the quiescently reverse-biased photocathode-MCP interface. Variable delay (≍ 30-ps jitter) between the gate pulse and the laser pulse permit tracing the MCP's optical response. Gating speeds, turn-on and turn-off patterns, the asymmetric spatial dependence of the MCP optical response, and resolution effects as functions of gate pulse width and photocathode-MCP bias have been characterized. Shutter times of >= 750 ps and <= 5 1p/mm resolution with the MCP fully on were observed. Variations in the intensity profiles of the phosphorl.s spatial response for uniform photocathode illumination are measured with a calibrated silicon-intensified-target (SIT) focus projection, scan (FPS) television camera and a high-speed video digitizer while photomultipliers (PMTs) monitor the laser pulse and the phosphor's spatially integrated output intensities. The characterization system, gating and biasing circuits, and experimental results will be presented.

  7. A MCP1 fusokine with CCR2-specific tumoricidal activity

    Directory of Open Access Journals (Sweden)

    Yuan Liangping

    2011-09-01

    Full Text Available Abstract Background The CCL2 chemokine is involved in promoting cancer angiogenesis, proliferation and metastasis by malignancies that express CCR2 receptor. Thus the CCL2/CCR2 axis is an attractive molecular target for anticancer drug development. Methods We have generated a novel fusion protein using GMCSF and an N-terminal truncated version of MCP1/CCL2 (6-76 [hereafter GMME1] and investigated its utility as a CCR2-specific tumoricidal agent. Results We found that distinct to full length CCL2 or its N-truncated derivative (CCL2 5-76, GMME1 bound to CCR2 on mouse lymphoma EG7, human multiple myeloma cell line U266, or murine and human medulloblastoma cell lines, and led to their death by apoptosis. We demonstrated that GMME1 specifically blocked CCR2-associated STAT3 phosphorylation and up-regulated pro-apoptotic BAX. Furthermore, GMME1 significantly inhibited EG7 tumor growth in C57BL/6 mice, and induced apoptosis of primary myeloma cells from patients. Conclusion Our data demonstrate that GMME1 is a fusokine with a potent, CCR2 receptor-mediated pro-apoptotic effect on tumor cells and could be exploited as a novel biological therapy for CCR2+ malignancies including lymphoid and central nervous system malignancies.

  8. A role for MCP-1/CCR2 in interstitial lung disease in children

    Directory of Open Access Journals (Sweden)

    Reinhardt Dietrich

    2005-08-01

    Full Text Available Abstract Background Interstitial lung diseases (ILD are chronic inflammatory disorders leading to pulmonary fibrosis. Monocyte chemotactic protein 1 (MCP-1 promotes collagen synthesis and deletion of the MCP-1 receptor CCR2 protects from pulmonary fibrosis in ILD mouse models. We hypothesized that pulmonary MCP-1 and CCR2+ T cells accumulate in pediatric ILD and are related to disease severity. Methods Bronchoalveolar lavage fluid was obtained from 25 children with ILD and 10 healthy children. Levels of pulmonary MCP-1 and Th1/Th2-associated cytokines were quantified at the protein and the mRNA levels. Pulmonary CCR2+, CCR4+, CCR3+, CCR5+ and CXCR3+ T cells were quantified by flow-cytometry. Results CCR2+ T cells and MCP-1 levels were significantly elevated in children with ILD and correlated with forced vital capacity, total lung capacity and ILD disease severity scores. Children with lung fibrosis had significantly higher MCP-1 levels and CCR2+ T cells in bronchoalveolar lavage fluid compared to non-fibrotic children. Conclusion The results indicate that pulmonary CCR2+ T cells and MCP-1 contribute to the pathogenesis of pediatric ILD and might provide a novel target for therapeutic strategies.

  9. Effect Of 1-MCP Treatment On Storage Potential Of Tomato Fruit

    Directory of Open Access Journals (Sweden)

    Wrzodak Anna

    2015-12-01

    Full Text Available Tomato fruit cv. ’Faustine’ F1 were harvested at mature green and full-red stages and treated with 1 or 2 µl·l−1 of 1-methylcyclopropene (1-MCP at 20 °C and 85-90% RH, for 21 hours to investigate the ability to delay ripening. Treated and control fruit were stored at 12.5 and 20 °C and 85-90% RH. Ethylene production, rate of respiration, weight loss, market value and storage life were determined after 4-week storage. Exposure of tomato fruit to 1-MCP reduced ethylene production and respiration rate of the fruit harvested at mature-green and full-red stages of maturity. Storage life and market value of tomato fruit depended on the treatment with 1-MCP, stage of maturity and storage temperature. Untreated fruits were characterized by the shortest storage life in comparison with the fruit treated with 1-MCP. The lowest market value was observed for tomato fruit harvested as a mature green, untreated with 1-MCP and stored at 20 °C. Treatment of tomato fruit with 1-MCP resulted in the reduction of natural weight loss during storage. These results suggest that 1-MCP treatment can be used in a commercial storage and trading system for tomatoes due to its ability to delay fruit ripening.

  10. NFAT5 Contributes to Osmolality-Induced MCP-1 Expression in Mesothelial Cells

    Directory of Open Access Journals (Sweden)

    Christoph Küper

    2012-01-01

    Full Text Available Increased expression of the C-C chemokine monocyte chemoattractant protein-1 (MCP-1 in mesothelial cells in response to high glucose concentrations and/or high osmolality plays a crucial role in the development of peritoneal fibrosis during continuous ambulatory peritoneal dialysis (CAPD. Recent studies suggest that in kidney cells osmolality-induced MCP-1 upregulation is mediated by the osmosensitive transcription factor, nuclear factor of activated T cells 5 (NFAT5. The present study addressed the question of whether activation of NFAT5 by hyperosmolality, as present in PD fluids, contributes to MCP-1 expression in the mesothelial cell line Met5A. Hyperosmolality, induced by addition of glucose, NaCl, or mannitol to the growth medium, increased NFAT5 activity and stimulated MCP-1 expression in Met5A cells. siRNA-mediated knockdown of NFAT5 attenuated osmolality-induced MCP-1 upregulation substantially. Hyperosmolality also induced activation of nuclear factor-κB (NF-κB. Accordingly, pharmacological inhibition of NF-κB significantly decreased osmolality-induced MCP-1 expression. Taken together, these results indicate that high osmolalities activate the transcription factor NFAT5 in mesothelial cells. NFAT5 in turn upregulates MCP-1, likely in combination with NF-κB, and thus may participate in the development of peritoneal fibrosis during CAPD.

  11. The serum concentrations of leptin and MCP-1 independently predict low back pain duration.

    Science.gov (United States)

    Lippi, Giuseppe; Dagostino, Concetta; Buonocore, Ruggero; Aloe, Rosalia; Bonaguri, Chiara; Fanelli, Guido; Allegri, Massimo

    2017-08-28

    Low back pain (LBP) is a very frequent condition, affecting most people at some point throughout their life. This cross-sectional study was aimed to investigate a selected panel of cytokines and inflammatory biomarkers in patients with or without LBP. The study population consisted of 104 patients diagnosed with LBP (52 non-persistent and 52 persistent) and 52 healthy subjects with no LBP. Blood samples were collected for assessment of adiponectin, leptin, monocyte chemoattractant protein-1 (MCP-1) and C reactive protein (CRP). The duration of LBP was categorized as "no pain", "non-persistent LBP" and "persistent LBP". Higher values of CRP and lower concentrations of both leptin and MCP-1 were found in LBP patients compared to controls, whereas adiponectin did not differ among groups. MCP-1 was also lower in patients with non-persistent than in those with persistent LBP. Age, leptin (relative risk, 11.8; 95% CI, 3.9-35.8) and MCP-1 (relative risk, 2.7; 95% CI, 1.7-4.4) were independently associated with presence and duration of LBP. The combination of age, leptin and MCP-1 predicted 61% of the risk of LBP duration. The area under the curve of MCP-1 for distinguishing persistent from non-persistent LBP was 0.65 (95% CI, 0.54-0.76). Then results of our study suggest that leptin and MCP-1 may be promising biomarkers for diagnosis of acute LBP and its risk to become chronic.

  12. Mechanism and role of MCP-1 upregulation upon chikungunya virus infection in human peripheral blood mononuclear cells

    NARCIS (Netherlands)

    Silva, Mariana Ruiz; van der Ende-Metselaar, Heidi; Mulder, H. Lie; Smit, Jolanda M.; Rodenhuis-Zybert, Izabela A.

    2016-01-01

    Monocyte chemoattractant protein-1 (MCP-1/CCL2)-mediated migration of monocytes is essential for immunological surveillance of tissues. During chikungunya virus (CHIKV) infection however, excessive production of MCP-1 has been linked to disease pathogenesis. High MCP-1 serum levels are detected duri

  13. Mechanism and role of MCP-1 upregulation upon chikungunya virus infection in human peripheral blood mononuclear cells

    NARCIS (Netherlands)

    Silva, Mariana Ruiz; van der Ende-Metselaar, Heidi; Mulder, H. Lie; Smit, Jolanda M.; Rodenhuis-Zybert, Izabela A.

    2016-01-01

    Monocyte chemoattractant protein-1 (MCP-1/CCL2)-mediated migration of monocytes is essential for immunological surveillance of tissues. During chikungunya virus (CHIKV) infection however, excessive production of MCP-1 has been linked to disease pathogenesis. High MCP-1 serum levels are detected duri

  14. 侵彻多层钢靶板过载测试技术%Overload Testing Technology of Penetrating Multi-Layer Steel Target Plate

    Institute of Scientific and Technical Information of China (English)

    张美云; 王敬斌; 王丹; 石庚辰

    2016-01-01

    针对在弹丸侵彻钢靶板过程中高过载带来的问题,研究了一种能够抗高冲击作用的弹丸侵彻多层钢靶板过载测试装置。该装置采用灌封、多层材料组合缓冲以及二次电源的措施,能保证测试装置抗高冲击作用和可靠工作。对弹丸侵彻多层钢靶板的过载特性进行了测试,结果表明所研究的测试装置能够可靠获取与记录弹丸穿过各层靶板时的加速度。%This paper presented a testing device with the ability of resisting high shock while penetrating multi-layer steel target plate to guarantee the high overload problem with plate process in the projectile penetrating steel target. Combined with potting technology, multi-layer shock absorb materials and secondary electrical power source,the device shows resistance to high shock and the ability of reliable working.Experiments on overload characteristic further proved that the device can collect and store the acceleration of penetrating multi-layer target plate with high reliability.

  15. MCP-1 expression by rat type II alveolar epithelial cells in primary culture.

    Science.gov (United States)

    Paine, R; Rolfe, M W; Standiford, T J; Burdick, M D; Rollins, B J; Strieter, R M

    1993-05-15

    Recruitment and activation of mononuclear phagocytes are potentially critical regulatory events for control of pulmonary inflammation. Located at the boundary between the alveolar airspace and the interstitium, alveolar epithelial cells are ideally situated to regulate the recruitment and activation of mononuclear phagocytes through the production of cytokines in response to inflammatory stimulation from the alveolar space. To test this hypothesis, we investigated the production of monocyte chemotactic polypeptide-1 (MCP-1), a protein that is chemotactic for and that activates monocytes, by rat type II alveolar epithelial cells in primary culture. Immunocytochemical staining using anti-murine JE, an antibody recognizing rat MCP-1, demonstrated cell-associated MCP-1 Ag throughout the monolayer. The intensity of staining was increased in response to IL-1 beta. When type II epithelial cells formed a tight monolayer on a filter support, there was polar secretion of MCP-1 Ag into the apical compartment by both control and IL-1-stimulated cells as measured by specific MCP-1 ELISA. Northern blot analysis revealed that IL-1 and TNF-alpha stimulated MCP-1 mRNA expression in a dose-dependent manner, whereas dexamethasone blocked MCP-1 expression by cells stimulated with IL-1. In contrast to previous results using transformed epithelial cell lines, MCP-1 mRNA was induced in these primary cultures directly by stimulation with LPS. These data suggest that alveolar epithelial cells may have an important and previously unrecognized role in the initiation and maintenance of inflammatory processes in the lung by recruiting and activating circulating monocytes through the production of MCP-1.

  16. MCP-1 secretion in lung from nonsmoking patients with coal worker`s pneumoconiosis

    Energy Technology Data Exchange (ETDEWEB)

    Boitelle, A.; Gosset, P.; Vanhee, D.; Wallaert, B.; Tonnel, A.B. [Institut Pasteur, INSERM U416, Lille (France); Copin, M.C.; Gosselin, B. [Service d`anatomie et de cytologie pathologique, CHRU, Lille (France); Marquette, C.H. [Hopital A. Calmette, Clinique des maladies respiratoires, Lille (France)

    1997-03-01

    Exposure to coal dust leads to development of coal worker`s pneumoconiosis (CWP), a disease associated with accumulation of macrophages in lower respiratory tract. Mechanisms controlling monocyte recruitment are still poorly understood. Since monocyte chemoattractant protein-1 (MCP-1) is recognized as a potent chemotactic factor for blood monocytes, we tested for presence of MCP-1 in pulmonary compartment of patients with CWP. Bronchoalveolar lavage fluid (BALF) from 16 nonsmoking control subjects and 27 nonsmoking CWP patients (16 with simple pneumoconiosis (SP) and 11 with progressive massive fibrosis (PMF)) was analysed. Alveolar macrophages (AMs) were purified by adherence and BALF was concentrated 10x by lyophilization. MCP-1 was measured in BALF and in 3 h AM supernatants using a sandwich enzyme-linked immunosorbent assay. Localization of MCP-1 in lung tissue was determined by immunohistochemistry on tissue sections from three patients with CWP and two control subjects. MCP-1 levels were higher in concentrated BALF from patients with SP or PMF (median 370 and 555 pg x mL{sup -1}, respectively) than in those form control subjects (median 11 pg x mL{sup -1}) (p<0.001). Released MCP-1 in AM supernatants was enhanced in patients with CWP (median 83 pg x mL{sup -1}) but compared to controls (median 41 pg x mL{sup -1}) this level did not reach significance. Although significantly increased, AM counts in BALF from patients with CWP did not correlate with MCP-1 levels. MCP-1 levels in BALF correlated with MCP-1 levels in AM supernatants ({rho}=0.47; p<0.02). Data demonstrate that: 1) patients with coal worker`s pneumoconiosis have a marked pulmonary overproduction of monocyte chemoattractant protein-1; and 2) in addition to alveolar macrophages, fibroblasts (probably myofibroblasts) and hyperplastic type II pneumocytes may also be responsible for this increased level of monocyte chemoattractant protein-1 in coal worker`s pneumoconiosis. (EG) 29 refs.

  17. Research of beam conditioning technologies using continuous phase plate, Multi-FM smoothing by spectral dispersion and polarization smoothing

    Science.gov (United States)

    Zhang, Rui; Jia, Huaiting; Tian, Xiaocheng; Yuan, Haoyu; Zhu, Na; Su, Jingqin; Hu, Dongxia; Zhu, Qihua; Zheng, Wanguo

    2016-10-01

    In the research of inertial confinement fusion, laser plasma interaction (LPI) is becoming a key problem that affects ignition. Here, multi-frequency modulation (Multi-FM) smoothing by spectral dispersion (SSD), continuous phase plate (CPP) and polarization smoothing (PS) were experimentally studied and implemented on the SG-III laser facility. After using these techniques, the far field distribution of SG-Ⅲ laser facility can be adjusted, controlled and repeated accurately. The output spectrums of the cascade phase modulators used for Multi-FM SSD were stable and the FM-to-AM effect can be restrained. Experiments on SG-III laser facility indicate that when the number of color cycles adopts 1, imposing SSD with 3.3 times diffraction limit (TDL) did not lead to pinhole closure in the spatial filters of preamplifier and main amplifiers with 30-TDL pinhole size. The nonuniformity of the focal spots using Multi-FM SSD, CPP and PS drops to 0.18, comparing to 0.26 with CPP+SSD, 0.57 with CPP+PS and 0.84 with only CPP and wedged lens. Polarization smoothing using flat birefringent plate in the convergent beam of final optics assembly (FOA) was studied. The PS plates were manufactured and equipped on SG-III laser facility for LPI research. Combined beam smoothing and polarization manipulation were also studied to solve the LPI problem. Results indicate that through adjusting dispersion directions of SSD beams in a quad, two dimensional SSD can be obtained. Using polarization control plate (PCP), polarization on the near field and far field can be manipulated, providing new method to solve LPI problem in indirect drive laser fusion.

  18. Experimental evaluation of the response of micro-channel plate detector to ions with 10s of MeV energies

    Science.gov (United States)

    Jeong, Tae Won; Singh, P. K.; Scullion, C.; Ahmed, H.; Kakolee, K. F.; Hadjisolomou, P.; Alejo, A.; Kar, S.; Borghesi, M.; Ter-Avetisyan, S.

    2016-08-01

    The absolute calibration of a microchannel plate (MCP) assembly using a Thomson spectrometer for laser-driven ion beams is described. In order to obtain the response of the whole detection system to the particles' impact, a slotted solid state nuclear track detector (CR-39) was installed in front of the MCP to record the ions simultaneously on both detectors. The response of the MCP (counts/particles) was measured for 5-58 MeV carbon ions and for protons in the energy range 2-17.3 MeV. The response of the MCP detector is non-trivial when the stopping range of particles becomes larger than the thickness of the detector. Protons with energies E ≳ 10 MeV are energetic enough that they can pass through the MCP detector. Quantitative analysis of the pits formed in CR-39 and the signal generated in the MCP allowed to determine the MCP response to particles in this energy range. Moreover, a theoretical model allows to predict the response of MCP at even higher proton energies. This suggests that in this regime the MCP response is a slowly decreasing function of energy, consistently with the decrease of the deposited energy. These calibration data will enable particle spectra to be obtained in absolute terms over a broad energy range.

  19. Quantitative analysis of the secretion of the MCP family of chemokines by muscle cells

    DEFF Research Database (Denmark)

    Henningsen, Jeanette; Pedersen, Bente Klarlund; Kratchmarova, Irina

    2011-01-01

    by Amino acids in Cell culture (SILAC) method for quantitative analysis resulted in the identification and generation of quantitative profiles of 59 growth factors and cytokines, including 9 classical chemokines. The members of the CC chemokine family of proteins such as monocyte chemotactic proteins 1, 2......, and 3 (MCP-1/CCL2, MCP-2/CCL8, and MCP-3/CCL7) showed a distinct pattern of secretion during differentiation. Further analysis using combinatorial RNA and protein approaches demonstrated that the MCPs are regulated via both post-transcriptional and post-translational mechanisms. Analyses...

  20. AB45. URO-MCP-1 mice: a model demonstrating UCPPS hallmark symptoms

    OpenAIRE

    Luo, Yi

    2014-01-01

    Introduction and objective Excessive production of monocyte chemotactic protein-1 (MCP-1) has been observed in various inflammatory, chronic pain, and bladder overactive conditions. We have observed that over half of patients with interstitial cystitis/bladder pain syndrome (IC/BPS) express elevated MCP-1 in the urine. This study was to develop a mouse model that secretes MCP-1 by the urothelium to facilitate the study of IC/BPS in humans. Methods A 4.9 Kb transgene consisting of the uroplaki...

  1. Production of Fission Product 99Mo using High-Enriched Uranium Plates in Polish Nuclear Research Reactor MARIA: Technology and Neutronic Analysis

    Directory of Open Access Journals (Sweden)

    Jaroszewicz Janusz

    2014-07-01

    Full Text Available The main objective of 235U irradiation is to obtain the 99mTc isotope, which is widely used in the domain of medical diagnostics. The decisive factor determining its availability, despite its short lifetime, is a reaction of radioactive decay of 99Mo into 99mTc. One of the possible sources of molybdenum can be achieved in course of the 235U fission reaction. The paper presents activities and the calculation results obtained upon the feasibility study on irradiation of 235U targets for production of 99Mo in the MARIA research reactor. Neutronic calculations and analyses were performed to estimate the fission products activity for uranium plates irradiated in the reactor. Results of dummy targets irradiation as well as irradiation uranium plates have been presented. The new technology obtaining 99Mo is based on irradiation of high-enriched uranium plates in standard reactor fuel channel and calculation of the current fission power generation. Measurements of temperatures and the coolant flow in the molybdenum installation carried out in reactor SAREMA system give online information about the current fission power generated in uranium targets. The corrective factors were taken into account as the heat generation from gamma radiation from neighbouring fuel elements as well as heat exchange between channels and the reactor pool. The factors were determined by calibration measurements conducted with aluminium mock-up of uranium plates. Calculations of fuel channel by means of REBUS code with fine mesh structure and libraries calculated by means of WIMS-ANL code were performed.

  2. Anisotropic elastic plates

    CERN Document Server

    Hwu, Chyanbin

    2010-01-01

    As structural elements, anisotropic elastic plates find wide applications in modern technology. The plates here are considered to be subjected to not only in plane load but also transverse load. In other words, both plane and plate bending problems as well as the stretching-bending coupling problems are all explained in this book. In addition to the introduction of the theory of anisotropic elasticity, several important subjects have are discussed in this book such as interfaces, cracks, holes, inclusions, contact problems, piezoelectric materials, thermoelastic problems and boundary element a

  3. Fast Micro-Channel Plate Detector for MIPs

    CERN Document Server

    Antropov, A E; Kasatkin, V A; Klempt, W; Kolojvari, A A; Kondratev, V P; Martinov, V; Lazarev, V A; Novikov, I A; Potapov, S V; Stolyarov, O I; Tsimbal, F A; Tulina, T A; Valiev, F F; Vinogradov, L I

    1999-01-01

    Abstract for the 6th International Conference on Advanced Technology and Particle Physics, to be held at Villa Olmo, Como, Italy, 5-9 October 1998. For a couple of the last decades Micro-channel plates (MCPs) are known as a fast (1 ns), fine granularity (5-12µ), high gain (103 -104), excellent time resolution (30-50 ps), high counting rate (1011 1/cm2 was reported) and efficient detector widely used in low energy nuclear physics. Nevertheless, these nice features have not been exploited sufficiently in the high energy experiments so far. The use of MCPs in the HEP experiments demands the developments of technologies different from the low-energy applications: in particular the low mass vacuum thin-wall chambers in the UHV technique. It is the great intrinsic capability of the MCPs for the registration of MIPs, high gain and sharp signals that prompted us to develop a fast multiplicity detector for ALICE at the LHC. The chevron MCP setup (gain up to 10*8) gives a strong signal for the Ultra High Freq...

  4. Accuracy of fibular sectioning and insertion into a rapid-prototyped bone plate, for mandibular reconstruction using CAD-CAM technology.

    Science.gov (United States)

    Ciocca, Leonardo; Marchetti, Claudio; Mazzoni, Simona; Baldissara, Paolo; Gatto, Maria Rosaria Antonella; Cipriani, Riccardo; Scotti, Roberto; Tarsitano, Achille

    2015-01-01

    Modern techniques of mandibular reconstruction, such as CAD-CAM technology and rapid prototyping, offer new means by which reconstructive surgery can be planned to optimise aesthetic outcomes and prosthetic rehabilitation. The high degree of accuracy afforded by these approaches is principally attributable to high-precision fibular sectioning and insertion of the bone into a customised bone plate. CAD-CAM mandibular reconstruction procedures using vascularised bone free-flap transfers were performed on 10 patients with benign or malignant neoplasms. Five were not treated with the aid of CAD-CAM technology, and served as the control group. Five were scheduled for maxillofacial surgery using surgical cutting guides and customised bone plates. A generalised linear model for linear measures was used to compare the accuracy of reconstruction between the two groups. A difference, even though not significant, in the lateral shift of the mesial and distal positions of the fibular units was evident between groups. CAD-CAM-generated fibular surgical guides afford improved accuracy when used to restore native anatomy, especially in the context of mandibular arch restoration, and both operating room time and related costs are reduced during fibular sectioning.

  5. Quantum efficiencies of imaging detectors with alkali halide photocathodes. I - Microchannel plates with separate and integral CsI photocathodes

    Science.gov (United States)

    Carruthers, George R.

    1987-01-01

    Measurements and comparisons have been made of the quantum efficiencies of microchannel plate (MCP) detectors in the far-UV (below 2000-A) wavelength range using CsI photocathodes (a) deposited on the front surfaces of microchannel plates and (b) deposited on solid substrates as opaque photocathodes with the resulting photoelectrons input to microchannel plates. The efficiences were measured in both pulse-counting and photodiode modes of operation. Typical efficiencies are about 15 percent at 1216 A for a CsI-coated MCP compared with 65 percent for an opaque CsI photocathode MCP detector. Special processing has yielded an efficiency as high as 20 percent for a CsI-coated MCP. This may possibly be further improved by optimization of the tilt angle of the MCP channels relative to the front face of the MCP and incident radiation. However, at present there still remains a factor of at least 3 quantum efficiency advantage in the separate opaque CsI photocathode configuration.

  6. Influence of rare earths addition on residual stress of Fe-based coating prepared by brush plating technology

    Institute of Scientific and Technical Information of China (English)

    JIN Guo; LU Bingwen; HOU Dingding; CUI Xiufang; SONG Jiahui; LIU Erbao

    2016-01-01

    The effect of rare earths (La, Ce and Pr) addition on residual stress in iron coatings prepared by brush plating was investi-gated. The results showed that the addition of rare earth transformed the residual stress in the coating from tensile to compressive. To relieve the residual stress, on the one hand, RE elements segregated at the grain boundaries which restricted the coalescence of the grains and provided more capability of grain deformation. On the other hand, RE elements could purify detrimental element and ab-sorb hydrogen atoms in the coating. Among the three rare earths, elements lanthanum showed the most significant effect on surface morphology and residual stress.

  7. Relationships between serum MCP-1 and subclinical kidney disease: African American-Diabetes Heart Study

    Directory of Open Access Journals (Sweden)

    Murea Mariana

    2012-11-01

    Full Text Available Abstract Background Monocyte chemoattractant protein-1 (MCP-1 plays important roles in kidney disease susceptibility and atherogenesis in experimental models. Relationships between serum MCP-1 concentration and early nephropathy and subclinical cardiovascular disease (CVD were assessed in African Americans (AAs with type 2 diabetes (T2D. Methods Serum MCP-1 concentration, urine albumin:creatinine ratio (ACR, estimated glomerular filtration rate (eGFR, and atherosclerotic calcified plaque (CP in the coronary and carotid arteries and infrarenal aorta were measured in 479 unrelated AAs with T2D. Generalized linear models were fitted to test for associations between MCP-1 and urine ACR, eGFR, and CP. Results Participants were 57% female, with mean ± SD (median age 55.6±9.5 (55.0 years, diabetes duration 10.3±8.2 (8.0 years, urine ACR 149.7±566.7 (14.0 mg/g, CKD-EPI eGFR 92.4±23.3 (92.0 ml/min/1.73m2, MCP-1 262.9±239.1 (224.4 pg/ml, coronary artery CP 280.1±633.8 (13.5, carotid artery CP 47.1±132.9 (0, and aorta CP 1616.0±2864.0 (319.0. Adjusting for age, sex, smoking, HbA1c, BMI, and LDL, serum MCP-1 was positively associated with albuminuria (parameter estimate 0.0021, P=0.04 and negatively associated with eGFR (parameter estimate −0.0003, P=0.001. MCP-1 remained associated with eGFR after adjustment for urine ACR. MCP-1 levels did not correlate with the extent of CP in any vascular bed, HbA1c or diabetes duration, but were positively associated with BMI. No interaction between BMI and MCP-1 was detected on nephropathy outcomes. Conclusions Serum MCP-1 levels are associated with eGFR and albuminuria in AAs with T2D. MCP-1 was not associated with subclinical CVD in this population. Inflammation appears to play important roles in development and/or progression of kidney disease in AAs.

  8. Phyllostachys edulis compounds inhibit palmitic acid-induced monocyte chemoattractant protein 1 (MCP-1 production.

    Directory of Open Access Journals (Sweden)

    Jason K Higa

    Full Text Available BACKGROUND: Phyllostachys edulis Carriere (Poaceae is a bamboo species that is part of the traditional Chinese medicine pharmacopoeia. Compounds and extracts from this species have shown potential applications towards several diseases. One of many complications found in obesity and diabetes is the link between elevated circulatory free fatty acids (FFAs and chronic inflammation. This study aims to present a possible application of P. edulis extract in relieving inflammation caused by FFAs. Monocyte chemoattractant protein 1 (MCP-1/CCL2 is a pro-inflammatory cytokine implicated in chronic inflammation. Nuclear factor kappa-light-chain-enhancer of activated B cells (NF-κB and activator protein 1 (AP-1 are transcription factors activated in response to inflammatory stimuli, and upregulate pro-inflammatory cytokines such as MCP-1. This study examines the effect of P. edulis extract on cellular production of MCP-1 and on the NF-κB and AP-1 pathways in response to treatment with palmitic acid (PA, a FFA. METHODOLOGY/PRINCIPAL FINDINGS: MCP-1 protein was measured by cytometric bead assay. NF-κB and AP-1 nuclear localization was detected by colorimetric DNA-binding ELISA. Relative MCP-1 mRNA was measured by real-time quantitative PCR. Murine cells were treated with PA to induce inflammation. PA increased expression of MCP-1 mRNA and protein, and increased nuclear localization of NF-κB and AP-1. Adding bamboo extract (BEX inhibited the effects of PA, reduced MCP-1 production, and inhibited nuclear translocation of NF-κB and AP-1 subunits. Compounds isolated from BEX inhibited MCP-1 secretion with different potencies. CONCLUSIONS/SIGNIFICANCE: PA induced MCP-1 production in murine adipose, muscle, and liver cells. BEX ameliorated PA-induced production of MCP-1 by inhibiting nuclear translocation of NF-κB and AP-1. Two O-methylated flavones were isolated from BEX with functional effects on MCP-1 production. These results may represent a possible

  9. 1-MCP pretreatment prevents bud and flower abscission in Dendrobium orchids

    NARCIS (Netherlands)

    Uthaichay, N.; Ketsa, S.; Doorn, van W.G.

    2007-01-01

    Dendrobium orchid inflorescences were treated for 4 h at 25 °C with or without 100¿500 nl/l 1-MCP and were then placed in water at 25 °C to follow abscission. In controls, depending on the experiment, 20¿80% of the floral buds and 0¿20% of the open flowers abscised within 1 week. The 1-MCP pretreatm

  10. Green Laser Marking Technology on Gold-plated Lid%镀金盖板上的绿激光标识技术

    Institute of Scientific and Technical Information of China (English)

    郭伟

    2014-01-01

    镀金盖板广泛用于军品集成电路的气密性封装中,其表面标识通常采用油墨移印工艺,但油墨移印的标识在筛选或考核过程中有时存在部分脱落的风险,造成鉴定难以通过。在镀金盖板上的绿激光标识技术,不仅解决了镀金盖板标识脱落的问题,而且解决了高可靠集成电路镀金盖板表面标识产品序列号的工艺难题。激光标识后的样品,顺利通过了按GJB548B要求进行的温度循环、热冲击、耐溶剂和盐雾等可靠性试验。对镀金盖板的激光标识区域进行了电镜扫描和解剖分析的结果表明,标识区域镀金层成份和金层厚度基本没有变化。%Gold Plated lid can be widely used for Hermetic package of integrated circuits.The marks on lid surface are usually made by offset printing with ink. But the ink mark, in the authentication process, exist partially exfoliated risk (Cause authentication through difficult). The green laser marking technology on gold-plated lid, has solved the problem well which marking falls off on gold-plated lid. At the same time also solves the process problem which printing serial number on gold-plated lid of the high reliability integrated circuits. The samples after laser marking,successfully passed the test of temperature cycle,heat concussion and the salt-fog test required by GJB548B standard. Laser marking area of gold-plated lid were analyzed by SEM and dissection. The results showed that the composition and thickness of the laser marking gold layer were unchanged.

  11. Sector Multipad Prototype of the FMD-MCP Detector for ALICE (1997)

    CERN Document Server

    Antropov, A E; Feofilov, G A; Izrailov, E K; Kasatkin, V A; Klempt, W; Kolojvari, A A; Larin, M P; Lazarev, V A; Novikov, I A; Potapov, S V; Stolyarov, O I; Tsimbal, F A; Tulina, T A; Valiev, F F; Vinogradov, L I

    1997-01-01

    We present results of the technology, manufacturing andfirst tests of a novel MCP-based sector prototypefor the Forward Multiplicity Detector for the ALICE experiment at the LHC. The detector is to provide better than sqrt(M)/Mresolution for high multiplicity events, and about 50 pstiming resolution. Two Sector MCPs are mounted on a 200 ceramics board with the multipad readout integrated with a passive summator. This microelectronics UHF device provides isochronous analogue summation of the fast 1ns signal components from 8 pads, along with the individual readout of charges. The setup is baked under 300C and then sealedinto a singular thin wall (200 ) stainlesssteel vacuum sector chamber with Ti getter keeping a vacuum of 10-5Torr.The separation of the fast and slow componentsallows us to use this detector as the zero level trigger,in pile up and beam-gas interaction diagnostics and for thedetermination of the collision vertex along the beam axis. The results of the first and future lab and in-beam tests are ...

  12. Multiple damage identification and imaging in an aluminum plate using effective Lamb wave response automatic extraction technology

    Science.gov (United States)

    Ouyang, Qinghua; Zhou, Li; Liu, Xiaotong

    2016-04-01

    In order to identify multiple damage in the structure, a method of multiple damage identification and imaging based on the effective Lamb wave response automatic extraction algorithm is proposed. In this method, the detected key area in the structure is divided into a number of subregions, and then, the effective response signals including the structural damage information are automatically extracted from the entire Lamb wave responses which are received by the piezoelectric sensors. Further, the damage index values of every subregion based on the correlation coefficient are calculated using the effective response signals. Finally, the damage identification and imaging are performed using the reconstruction algorithm for probabilistic inspection of damage (RAPID) technique. The experimental research was conducted using an aluminum plate. The experimental results show that the method proposed in this research can quickly and effectively identify the single damage or multiple damage and image the damages clearly in detected area.

  13. 氰化滚镀铜工艺实践与探讨%Practice and Exploration of Technology for Barrel Copper Plating from a Cyanide Bath

    Institute of Scientific and Technical Information of China (English)

    郭崇武; 李健强

    2009-01-01

    氰化滚镀铜溶液中碳酸钠含量和主盐浓度不当,都会影响产品的质量.影响碳酸钠含量的因素较多,如溶液的pH值及NaOH浓度,槽电压等.对其具体影响进行了研究,提出措施:NaOH浓度在5.0~7.5 g/L可以将碳酸钠浓度控制在工艺范围内;降低镀槽电压和增加阳极面积有利于降低碳酸钠的浓度;较高的主盐浓度可以提高镀液的电流效率和均镀能力,有利于降低电镀成本.%The concentrations of sodium hydroxide and sodium carbonate in a barrel cyanide copper-plating bath were determined by chemical analysis, ai-ming at revealing the effect of sodium hydroxide on the formation and concentration of sodium carbonate and hence the quality of the final coating. Results show that the concentration of sodium carbonate in the bath for barrel cyanide copper- plating of zinc work pieces can be effectively controlled within the required range of technology by introducing 5.0 ~ 7. 5 g/L sodium hydroxide. Moreover, reducing the voltage of the plating bath and increasing the anodic area are favorable to decreasing the concentration of sodium carbonate. And raising the concentration of cuprous cya-nide as the main salt is helpful to increasing the current efficiency and throwing power and reducing the electroplating cost as well.

  14. Mechanism and role of MCP-1 upregulation upon chikungunya virus infection in human peripheral blood mononuclear cells

    Science.gov (United States)

    Ruiz Silva, Mariana; van der Ende-Metselaar, Heidi; Mulder, H. Lie; Smit, Jolanda M.; Rodenhuis-Zybert, Izabela A.

    2016-01-01

    Monocyte chemoattractant protein-1 (MCP-1/CCL2)-mediated migration of monocytes is essential for immunological surveillance of tissues. During chikungunya virus (CHIKV) infection however, excessive production of MCP-1 has been linked to disease pathogenesis. High MCP-1 serum levels are detected during the viremic phase of CHIKV infection and correlate with the virus titre. In vitro CHIKV infection was also shown to stimulate MCP-1 production in whole blood; yet the role and the mechanism of MCP-1 production upon infection of human peripheral blood mononuclear cells remain unknown. Here we found that active CHIKV infection stimulated production of MCP-1 in monocytes. Importantly however, we found that communication with other leukocytes is crucial to yield MCP-1 by monocytes upon CHIKV infection. Indeed, blocking interferon-α/β receptor or the JAK1/JAK2 signalling downstream of the receptor abolished CHIKV-mediated MCP-1 production. Additionally, we show that despite the apparent correlation between IFN type I, CHIKV replication and MCP-1, modulating the levels of the chemokine did not influence CHIKV infection. In summary, our data disclose the complexity of MCP-1 regulation upon CHIKV infection and point to a crucial role of IFNβ in the chemokine secretion. We propose that balance between these soluble factors is imperative for an appropriate host response to CHIKV infection. PMID:27558873

  15. Role of MCP-1 in alcohol-induced aggressiveness of colorectal cancer cells.

    Science.gov (United States)

    Xu, Mei; Wang, Siying; Qi, Yuanlin; Chen, Li; Frank, Jacqueline A; Yang, Xiuwei H; Zhang, Zhuo; Shi, Xianglin; Luo, Jia

    2016-05-01

    Epidemiological studies demonstrate that alcohol consumption is associated with an increased risk of colorectal cancer (CRC). In addition to promoting carcinogenesis, alcohol may also accelerate the progression of existing CRC. We hypothesized that alcohol may enhance the aggressiveness of CRC. In this study, we investigated the effect of alcohol on the migration/invasion and metastasis of CRC. Alcohol increased the migration/invasion of colorectal cancer cells (DLD1, HCT116, HT29, and SW480) in a concentration-dependent manner. Among these colon cancer cell lines, HCT116 cells were most responsive while HT29 cells were the least responsive to ethanol-stimulated cell migration/invasion. These in vitro results were supported by animal studies which demonstrated that ethanol enhanced the metastasis of colorectal cancer cells to the liver and lung. Monocyte chemoattractant protein-1 (MCP-1) is a chemokine that plays an important role in regulating tumor microenvironment and metastasis. Alcohol increased the expression of MCP-1 and its receptor CCR2 at both protein and mRNA levels. The pattern of alcohol-induced alterations in MCP-1 expression was consistent with its effect on migration/invasion; HCT116 cells displayed the highest up-regulation of MCP-1/CCR2 in response to alcohol exposure. An antagonist of CCR2 blocked alcohol-stimulated migration. Alcohol caused an initial cytosolic accumulation of β-catenin and its subsequent nuclear translocation by inhibiting GSK3β activity. Alcohol stimulated the activity of MCP-1 gene promoter in a β-catenin-dependent manner. Furthermore, knock-down of MCP-1/CCR2 or β-catenin was sufficient to inhibit alcohol-induced cell migration/invasion. Together, these results suggested that alcohol may promote the metastasis of CRC through modulating GSK3β/β-catenin/MCP-1 pathway. © 2015 Wiley Periodicals, Inc.

  16. St. John's Wort protein, p27SJ, regulates the MCP-1 promoter.

    Science.gov (United States)

    Mukerjee, Ruma; Deshmane, Satish L; Darbinian, Nune; Czernik, Marta; Khalili, Kamel; Amini, Shohreh; Sawaya, Bassel E

    2008-09-01

    St. John's Wort is commonly known for its antiviral, antidepressant, and cytotoxic properties, but traditionally St. John's Wort has also been used to treat inflammation. In this study, we sought to characterize the mechanisms used by St. John's Wort to treat inflammation by examining the effect of the recently isolated protein from St. John's Wort, p27SJ on the expression of MCP-1. By employing an adenovirus expression vector, we demonstrate that a low concentration of p27SJ upregulates the MCP-1 promoter through the transcription factor C/EBPbeta. In addition, we found that C/EBPbeta-homologous protein (CHOP) or siRNA-C/EBPbeta significantly reduced the ability of p27SJ to activate MCP-1 gene expression. Results from protein-protein interaction studies illustrate the existence of a physical interaction between p27SJ and C/EBPbeta in microglial cells. The use of chromatin immunoprecipitation assay (ChIP) led to the identification of a new cis-element that is responsive to C/EBPbeta within the MCP-1 promoter. Association of C/EBPbeta with MCP-1 DNA was not affected by the presence of p27SJ. The biological activity of MCP-1 produced by cultures of adenovirus-p27SJ transduced cells was increased relative to controls as measured by the transmigration of human Jurkat cells. Thus, we conclude that at high concentration, p27SJ is a potential agent that may be developed as a modulator of MCP-1 leading to the inhibition of the cytokine-mediated inflammatory responses.

  17. Monocyte chemoattractant protein-1 (MCP-1 regulates macrophage cytotoxicity in abdominal aortic aneurysm.

    Directory of Open Access Journals (Sweden)

    Qiwei Wang

    Full Text Available AIMS: In abdominal aortic aneurysm (AAA, macrophages are detected in the proximity of aortic smooth muscle cells (SMCs. We have previously demonstrated in a murine model of AAA that apoptotic SMCs attract monocytes and other leukocytes by producing MCP-1. Here we tested whether infiltrating macrophages also directly contribute to SMC apoptosis. METHODS AND RESULTS: Using a SMC/RAW264.7 macrophage co-culture system, we demonstrated that MCP-1-primed RAWs caused a significantly higher level of apoptosis in SMCs as compared to control macrophages. Next, we detected an enhanced Fas ligand (FasL mRNA level and membrane FasL protein expression in MCP-1-primed RAWs. Neutralizing FasL blocked SMC apoptosis in the co-culture. In situ proximity ligation assay showed that SMCs exposed to primed macrophages contained higher levels of receptor interacting protein-1 (RIP1/Caspase 8 containing cell death complexes. Silencing RIP1 conferred apoptosis resistance to SMCs. In the mouse elastase injury model of aneurysm, aneurysm induction increased the level of RIP1/Caspase 8 containing complexes in medial SMCs. Moreover, TUNEL-positive SMCs in aneurysmal tissues were frequently surrounded by CD68(+/FasL(+ macrophages. Conversely, elastase-treated arteries from MCP-1 knockout mice display a reduction of both macrophage infiltration and FasL expression, which was accompanied by diminished apoptosis of SMCs. CONCLUSION: Our data suggest that MCP-1-primed macrophages are more cytotoxic. MCP-1 appears to modulate macrophage cytotoxicity by increasing the level of membrane bound FasL. Thus, we showed that MCP-1-primed macrophages kill SMCs through a FasL/Fas-Caspase8-RIP1 mediated mechanism.

  18. Die Analyse der Inhibition des Monozyten chemotaktischen Proteins-1 (MCP-1) und der Stimulation durch MCP-1 auf die Koloniebildung und die Zytokinexpression von Plattenepithelkarzinomen der Kopf-Hals-Region im FLAVINO-Assay

    OpenAIRE

    Körner, Carolin

    2015-01-01

    Das Monozyten chemotaktische Protein-1 (MCP-1) ist ein CC-Chemokin, das in seiner Rolle als Chemoattraktor auf Monozyten in der Genese von Malignomen eine wesentliche Rolle spielt. Dabei kann es sowohl zur lokalen Tumorabwehr als auch zur Tumorgenese, Tumor-angiogenese und Metastasierung beitragen. Die vorliegende Arbeit untersucht die MCP-1-Inhibition und die Stimulation durch MCP-1 auf die Koloniebildung und die Zytokinexpression von Plattenepithelkarzinomen der Kopf-Hals-Region (HNSCC) im ...

  19. Protective effects of MCP-1 inhibitor on a rat model of severe acute pancreatitis

    Institute of Scientific and Technical Information of China (English)

    Guo-Xiong Zhou; Xue-Juan Zhu; Xiao-Ling Ding; Hong Zhang; Jian-Ping Chen; Hui Qiang; Hai-Feng Zhang; Qun Wei

    2010-01-01

    BACKGROUND: Chemokines and their receptors play key roles in the pathogenesis of acute pancreatitis. This study aimed to establish a rat model of severe acute pancreatitis (SAP) for investigating monocyte chemotactic protein-1 (MCP-1) expression in the pathogenesis of the disease. We assessed the effects of the inhibitor of MCP-1, Bindarit, on SAP and explored the mechanisms underlying SAP. METHODS: Seventy-two Sprague-Dawley rats were randomly divided into a saline control group (group S), an SAP group (group P), and a Bindarit group (group T). The SAP model was induced by retrograde infusion of 4% sodium taurocholate into the bilio-pancreatic duct. Based on the SAP model, Bindarit was injected intraperitoneally in group T, and 0.5%methyl cellulose was injected intraperitoneally in groups S and P. In group S, saline was retrogradely infused into the bili-pancreatic duct. Serum amylase levels and the histological changes in the pancreas were assessed at different time-points in each group. Expression of MCP-1 in serum was measured by enzyme-linked immunoadsorbent assay (ELISA). MCP-1 protein and mRNA expression levels were detected by immunohistochemistry, Western blotting, and semi-quantitative reverse transcriptase-polymerase chain reaction (RT-PCR). RESULTS: Serum amylase levels in groups P and T were higher than those in group S. Serum amylase levels were signiifcantly lower in group T than in group P at 6 and 12 hours after operation. The levels of MCP-1 in serum at 6 and 12 hours after operation in group P were signiifcantly higher than in group S, and signiifcantly lower in group T than in group P at 6 and 12 hours after operation. The pathological damage in the pancreas was milder in group T than in group P. MCP-1 protein and mRNA expression levels in the pancreas were higher in groups P and T than in group S. These expression levels were positively correlated with the pathological damage of pancreatic tissues. The activity of MCP-1 in group T was

  20. IL-8 and MCP Gene Expression and Production by LPS-Stimulated Human Corneal Stromal Cells

    Directory of Open Access Journals (Sweden)

    Roni M. Shtein

    2012-01-01

    Full Text Available Purpose. To determine time course of effect of lipopolysaccharide (LPS on production of interleukin-8 (IL-8 and monocyte chemotactic protein (MCP by cultured human corneal stromal cells. Methods. Human corneal stromal cells were harvested from donor corneal specimens, and fourth to sixth passaged cells were used. Cell cultures were stimulated with LPS for 2, 4, 8, and 24 hours. Northern blot analysis of IL-8 and MCP gene expression and ELISA for IL-8 and MCP secretion were performed. ELISA results were analyzed for statistical significance using two-tailed Student's t-test. Results. Northern blot analysis demonstrated significantly increased IL-8 and MCP gene expression after 4 and 8 hours of exposure to LPS. ELISA for secreted IL-8 and MCP demonstrated statistically significant increases (P<0.05 after corneal stromal cell stimulation with LPS. Conclusions. This paper suggests that human corneal stromal cells may participate in corneal inflammation by secreting potent leukocyte chemotactic and activating proteins in a time-dependent manner when exposed to LPS.

  1. Sinorhizobium meliloti chemotaxis to quaternary ammonium compounds is mediated by the chemoreceptor McpX.

    Science.gov (United States)

    Webb, Benjamin A; Karl Compton, K; Castañeda Saldaña, Rafael; Arapov, Timofey D; Keith Ray, W; Helm, Richard F; Scharf, Birgit E

    2017-01-01

    The bacterium Sinorhizobium meliloti is attracted to seed exudates of its host plant alfalfa (Medicago sativa). Since quaternary ammonium compounds (QACs) are exuded by germinating seeds, we assayed chemotaxis of S. meliloti towards betonicine, choline, glycine betaine, stachydrine and trigonelline. The wild type displayed a positive response to all QACs. Using LC-MS, we determined that each germinating alfalfa seed exuded QACs in the nanogram range. Compared to the closely related nonhost species, spotted medic (Medicago arabica), unique profiles were released. Further assessments of single chemoreceptor deletion strains revealed that an mcpX deletion strain displayed little to no response to these compounds. Differential scanning fluorimetry showed interaction of the isolated periplasmic region of McpX (McpX(PR) and McpX34-306 ) with QACs. Isothermal titration calorimetry experiments revealed tight binding to McpX(PR) with dissociation constants (Kd ) in the nanomolar range for choline and glycine betaine, micromolar Kd for stachydrine and trigonelline and a Kd in the millimolar range for betonicine. Our discovery of S. meliloti chemotaxis to plant-derived QACs adds another role to this group of compounds, which are known to serve as nutrient sources, osmoprotectants and cell-to-cell signalling molecules. This is the first report of a chemoreceptor that mediates QACs taxis through direct binding.

  2. Assessment of chemical composition of tomato fruits depending on the cultivar and 1-MCP treatment

    Directory of Open Access Journals (Sweden)

    Anna Wrzodak

    2016-09-01

    Full Text Available The experiments on influence of 1-MCP treatment on the content of some chemical compounds in tomato fruits were performed. For the experiments two greenhouse cultivars of tomato were selected: ‘Faustine F1’ and ‘Habana F1’ (LSL type – long shelf life. Both tomato cultivars were grown on stakes in the field. Tomato fruits were harvested in mature green and full-red stages of maturity. Tomato fruit were treated with 1-MCP at the concentrations of 1.0 or 2.0 μl·l-1 and then stored at the temperature of 12.5°C or 20°C, and 85–90% of relative humidity in ambient atmosphere. Immediately after harvest and after 4 weeks of storage chemical analyses were carried out. The results showed some significant differences in the content of determined compounds depending on 1-MCP treatment, stage of maturity and storage temperature. Fruits of both cultivars showed a higher content of phenolics and dry matter in the case of fruits treated with 1-MCP. The highest content of lycopene was found in tomato fruits of both cultivars harvested in full-red stage, after storage at 20°C. Tomato fruits treated with 1-MCP were characterized by a lower content of lycopene and vitamin C compared to the untreated fruits.

  3. The production of monocyte chemoattractant protein-1 (MCP-1)/CCL2 in tumor microenvironments.

    Science.gov (United States)

    Yoshimura, Teizo

    2017-02-08

    Infiltration of leukocytes is one of the hallmarks of the inflammatory response. Among the leukocyte populations, neutrophils are the first to infiltrate, followed by monocytes and lymphocytes, suggesting the presence of mediators that specifically recruit these cell types. Cytokine-like chemoattractants with monocyte chemotactic activity, such as lymphocyte-derived chemotactic factor (LDCF) or tumor-derived chemotactic factor (TDCF), were reported as molecules that could play a critical role in the recruitment of monocytes into sites of immune responses or tumors; however, their identities remained unclear. In the 1980s, researchers began to test the hypothesis that leukocyte chemotactic activity is a part of the wider activities exhibited by cytokines, such as interleukin-1 (IL-1). In 1987, we demonstrated, for the first time, the presence of a cytokine like chemoattractant with cell type-specificity (now known as the chemokine interleukin-8 or CXC chemokine ligand 8) that was different from IL-1. This led us to the purification of the second such molecule with monocyte chemotactic activity. This monocyte chemoattractant was found identical to the previously described LDCF or TDCF, and termed monocyte chemoattractant protein-1 (MCP-1). Isolation of MCP-1 created a revolution in not only inflammation but also cancer research that continues today, and MCP-1 has become a molecular target to treat patients with many diseases. In this review, I will first describe a history associated with the discovery of MCP-1 and then discuss complex mechanisms regulating MCP-1 production in tumor microenvironments.

  4. Exosomes derived from MSCs ameliorate retinal laser injury partially by inhibition of MCP-1

    Science.gov (United States)

    Yu, Bo; Shao, Hui; Su, Chang; Jiang, Yuanfeng; Chen, Xiteng; Bai, Lingling; Zhang, Yan; Li, Qiutang; Zhang, Xiaomin; Li, Xiaorong

    2016-01-01

    Although accumulated evidence supports the notion that mesenchymal stem cells (MSCs) act in a paracrine manner, the mechanisms are still not fully understood. Recently, MSC-derived exosomes (MSC-Exos), a type of microvesicle released from MSCs, were thought to carry functional proteins and RNAs to recipient cells and play therapeutic roles. In the present study, we intravitreally injected MSCs derived from either mouse adipose tissue or human umbilical cord, and their exosomes to observe and compare their functions in a mouse model of laser-induced retinal injury. We found that both MSCs and their exosomes reduced damage, inhibited apoptosis, and suppressed inflammatory responses to obtain better visual function to nearly the same extent in vivo. Obvious down-regulation of monocyte chemotactic protein (MCP)-1 in the retina was found after MSC-Exos injection. In vitro, MSC-Exos also down-regulated MCP-1 mRNA expression in primarily cultured retinal cells after thermal injury. It was further demonstrated that intravitreal injection of an MCP-1-neutralizing antibody promoted the recovery of retinal laser injury, whereas the therapeutic effect of exosomes was abolished when MSC-Exos and MCP-1 were administrated simultaneously. Collectively, these results suggest that MSC-Exos ameliorate laser-induced retinal injury partially through down-regulation of MCP-1. PMID:27686625

  5. Macrophage Migration Inhibitor Factor Upregulates MCP-1 Expression in an Autocrine Manner in Hepatocytes during Acute Mouse Liver Injury

    OpenAIRE

    Jieshi Xie; Le Yang; Lei Tian; Weiyang Li; Lin Yang; Liying Li

    2016-01-01

    Macrophage migration inhibitor factor (MIF), a multipotent innate immune mediator, is an upstream component of the inflammatory cascade in diseases such as liver disease. Monocyte chemoattractant protein-1 (MCP-1), a highly representative chemokine, is critical in liver disease pathogenesis. We investigated the role of MIF in regulating hepatocytic MCP-1 expression. MIF and MCP-1 expression were characterized by immunochemistry, RT-PCR, ELISA, and immunoblotting in CCl4-treated mouse liver an...

  6. A new technology for sandwich plates and structures based on the use of in-situ foamable thermoplastic films

    Science.gov (United States)

    Beukers, Adriaan

    The cost effectiveness of structures in transports is basically depending on the operational capability and availability, the so called structure effectiveness, per unit cost. These costs are mainly determined by the cost to manufacture (acquisition costs) and the costs to operate (mass) and to maintain (damage sensitivity). In this paper the attention is focused on a new approach leading to efficiency improving sandwich material concepts, structures and related manufacturing processes, satisfying the value for money criterion as formulated by the cost effectiveness criterion. The sandwich materials and technology applied are based on the use of thermoformable continuous fiber reinforced thermoplastic polymers, in particular E-glass reinforced polyetherimide (PEI).

  7. 锆钢复合板反应器制作技术%Relative Manufacturing Technology on Zirconium- steel Clad Plate Reactor

    Institute of Scientific and Technical Information of China (English)

    汪雪涛; 高振宇

    2009-01-01

    Some key technology and method on the manufacturing zirconium - steel clad plate reactor is presented. This paper summarizes and compares some different solutions during the domestic manufacture process, then some comparative better solution were found out. These solution and technology is proved good for the equipment quality and the production etficiency through the manufacture practice and some relative analyze, so it's worth to be spread and referenced to other similar equipment manufacture.%介绍了锆钢复合板反应设备国产化过程中的一些重点技术.通过总结、比较的方法,得出较优的一些解决方案.通过实际生产应用的效果及原理分析,可以看出这些技术方案有利于保证设备质量并提高生产效率,对以后类似设备的制作具有推广及借鉴作用.

  8. Technological study of Ni-P-PTFE electroless composite plating%化学复合镀Ni-P-PTFE的工艺研究

    Institute of Scientific and Technical Information of China (English)

    冯婧

    2014-01-01

    Ni-P-PTFE electroless composite plating on differ-ent parameters and studying the effect of PTFE content in the coat-ing. The results show that PTFE content in the coating reached a peak with the increase of different technological parameters of surfac-tants concentration, temperature and stirring speed. Too large or too small about the the technological parameters is bad for the adsorp-tion of the PTFE particles.%在不同的工艺参数下进行化学复合镀Ni-P-PTFE,研究了工艺参数对复合镀层PTFE含量的影响。结果表明,随工艺参数表面活性剂含量、温度和搅拌速度的增加,镀层中PTFE的含量都会达到一个峰值,工艺参数过大或过小,都不利于镀层PTFE粒子的吸附。

  9. CHANGES IN MECHANICAL PROPERTIES OF MINIMALLY-PROCESSED YELLOW PITAHAYA TREATED WITH 1-MCP

    Directory of Open Access Journals (Sweden)

    LILIANA SERNA COCK

    2012-01-01

    Full Text Available Se evaluaron las propiedades mecánicas de esfuerzo del límite de fluencia (sL, modulo de deformación (Ed, esfuerzo de ruptura (sF, y deformación de Hencky en la ruptura (eHF de muestras de pitahaya amarilla mínimamente procesada y tratadas con 200 μgL-1 de 1-MCP durante el almacenamiento a 10±1 °C y 85% de humedad relativa. Las muestras fueron sometidas a pruebas de compresión uniaxial hasta la ruptura. Los resultados mostraron que las muestras tratadas con 1-MCP presentaron los mayores valores del esfuerzo del límite de fluencia, modulo de elasticidad y esfuerzo de ruptura. Esto indica que la aplicación del 1-MCP proporciona mayor firmeza a la fruta y puede representar una alternativa para disminuir cambios indeseables de textura durante el almacenamiento.

  10. The study of the aging behavior on large area MCP-PMT

    CERN Document Server

    Wang, Wen-Wen; Qi, Ming; Xia, Jing-Kai; Cheng, Ya-Ping; Ning, Zhe; Luo, Feng-Jiao; Heng, Yue-Kun; Liu, Shu-Lin; Si, Shu-Guang; Sun, Jian-Ning; Li, Dong; Wang, Xing-Chao; Huang, Guo-Rui; Tian, Jing-Shou; Wei, Yong-Lin; Liu, Hu-Lin; Li, Wei-Hua; Wang, Xing; Xin, Li-Wei

    2015-01-01

    Aging experiments of a novel type of large area MCP-PMT made by JUNO collaboration were conducted.In these aging experiments, the multi-photoelectron spectrum and single photoelectron spectrum were measured daily,as well as the MCP resistance of the second PMT before and after the experiment. Two PMTs were aged successivelyfor cross check. The first PMT was aged for 52 days, while the other one was aged for 84 days. In order to study the mechanism of the aging process, the high voltage on the second PMT was increased to accelerate its aging process when the cumulative output of charge from its anode was about 4 C. From our study, it can be known that large area MCP-PMT aging had a strong relationship with the related MCPs. In accordance with the PMT aging curve,a PMT aging model was setup and a general aging formula was given.

  11. [Effect of 1-MCP on senescence and quality in cold-stored edible podded pea].

    Science.gov (United States)

    Wang, Feng; Zheng, Yong-Hua; Zhang, Lan; Feng, Lei; Su, Xin-Guo; Jiang, Yue-Ming

    2004-04-01

    The effects of 1-MCP (1-methylcyclo-propene) at 0.5, 1 and 2 muL/L on senescence and quality attributes in edible podded pea (Pisum sativum L.var.Saccharatum) during cold storage at 1 degrees C were investigated. The results indicated that treatments with 1 and 2 microL/L 1-MCP significantly inhibited respiratory rate, ethylene production and superoxide production, maintained higher levels of SOD, AsA-POD activities and chlorophyll and AsA contents, reduced the increases in MDA and fiber contents and decay index, thereby delayed the senescence process and quality deterioration. Treatment with 0.5 microL/L 1-MCP showed no significant effects on senescence and quality changes in harvested edible podded pea.

  12. Development of microchannel plates in advanced wind-tunnel instrumentation

    Science.gov (United States)

    Feller, W. Bruce

    1990-01-01

    Microchannel plate (MCP) electron multiplier dynamic range has been increased 3 to 4 orders of magnitude at ambient temperatures, through enhanced input count rate capability and reduced background or 'dark' noise. The previous upper limit of roughly 10(exp 7) - 10(exp 8) cm(exp -2)s(exp -1) at ambient has been extended to levels approach 10(exp 10) cm(exp -2)s(exp -1) under continuous dc operation. The lower limit, previously set by an irreducible background component (approximately 0.6 cm(exp -2)s(exp -1)), has been lowered to the cosmic ray limit of .01 cm(exp -2)s(exp -1). The high end improvement was achieved by conductively cooling a very low resistance MCP by bonding it to a heat sink, while maintaining pulse-counting operation with multianode readouts. The low-end improvement was achieved by removing all radioisotopes from the MCP matrix glass. The detectors will benefit optical and mass spectrometry, flow visualization, plasma diagnostics, magnetometry, and other high signal flux applications. Very low MCP background noise will benefit X-ray and UV astronomy, medical imaging, trace isotope mass spectrometry, and other applications where the signal flux is often extremely low.

  13. Evaluation of nitrogen gas accumulated inside MCP during natural circulation operation of SMART

    Energy Technology Data Exchange (ETDEWEB)

    Choi, B. S.; Kim, Y. I.; Seo, J. K.; Park, C. T.; Lee, D. J.; Jang, M. H. [KAERI, Taejon (Korea, Republic of)

    2001-10-01

    With nitrogen used in pressurizer, primary coolant of SMART will contain dissolved nitrogen. The solubility of nitrogen gas in water is calculated as a function of temperature and pressure by Himmelblau equation based on Henry's law. It is found that the nitrogen concentration of primary coolant is highly dependent upon thermal-hydraulic parameters of the primary system, temperature, pressure and heatup rate. The accumulated nitrogen gas within MCP is evaluated based on the assumed natural convective flows established between SMART core and MCP. It is concluded that the natural circulation time is varied from 100 {approx} 1000 hrs according to the natural convection flows.

  14. Sensory Quality of ‘Cherry’ Tomatoes in Relation to 1-MCP Treatment and Storage Duration

    OpenAIRE

    Marek GAJEWSKI; Mazur, Katarzyna; Jadwiga RADZANOWSKA; Kowalczyk, Katarzyna; Marcinkowska, Monika; Klaudyna RYL; Karolina KALOTA

    2014-01-01

    1-MCP (1-methylcyclopropene), the ethylene receptors blocker, is used in horticultural practice for prolonging ‘shelf-life’ of several species of fruits and vegetables. The objective of this study was to determine the effect of 1-MCP treatment on sensory characteristics of ‘cherry’ type tomatoes (Solanum lycopersicum L. var. cerasiforme) after 4-week storage. In the experiment the fruits were harvested at pink and light-red fruit stages (3rd and 5th stage, according to USDA classification), a...

  15. Effect Of 1-MCP Treatment On Storage Potential Of Tomato Fruit

    OpenAIRE

    Wrzodak Anna; Gajewski Marek

    2015-01-01

    Tomato fruit cv. ’Faustine’ F1 were harvested at mature green and full-red stages and treated with 1 or 2 µl·l−1 of 1-methylcyclopropene (1-MCP) at 20 °C and 85-90% RH, for 21 hours to investigate the ability to delay ripening. Treated and control fruit were stored at 12.5 and 20 °C and 85-90% RH. Ethylene production, rate of respiration, weight loss, market value and storage life were determined after 4-week storage. Exposure of tomato fruit to 1-MCP reduced ethylene production and respirati...

  16. MCP-1 Levels are Associated with Cardiac Remodeling but not with Resistant Hypertension.

    Science.gov (United States)

    Ritter, Alessandra Mileni Versuti; Faria, Ana Paula Cabral de; Sabbatini, Andrea; Corrêa, Nathalia Batista; Brunelli, Veridiana; Modolo, Rodrigo; Moreno, Heitor

    2017-04-01

    Hypertension is a chronic, low-grade inflammation process associated with the release of cytokines and development of target organ damage. Deregulated monocyte chemoattractant protein-1 (MCP-1) levels have been associated with high blood pressure and cardiovascular complications; however, the mechanisms involved are complex and not fully understood. This study aimed to compare the levels of MCP-1 in patients with resistant (RH) versus mild-to-moderate (HTN) hypertension and their association with the presence or absence of left ventricular hypertrophy (LVH) in all hypertensive subjects. We enrolled 256 hypertensive subjects: 120 RH and 136 HTN, investigating the relationship between circulating MCP-1 levels and blood pressure, biochemical data, hematologic profile, and cardiac damage within the RH and HTN groups. Plasma MCP-1 levels were measured by ELISA and LVH was assessed by echocardiography. We found no difference in MCP-1 levels between RH and HTN subjects. On the other hand, we encountered lower MCP-1 levels in patients with LVH (105 pg/mL [100 - 260 pg/mL] versus 136 pg/mL (100 - 200 pg/mL), p = 0.005, respectively] compared with those without LVH. A logistic regression model adjusted for body mass index (BMI), age, race, aldosterone levels, and presence of diabetes and RH demonstrated that median levels of MCP-1 (2.55 pg/mL [1.22 - 5.2 pg/mL], p = 0.01) were independently associated with LVH in the entire hypertensive population. Since MCP-1 levels were similar in both RH and HTN subjects and decreased in hypertensive patients with existing LVH, our study suggests a possible downregulation in MCP-1 levels in hypertensive individuals with LVH, regardless of hypertension strata. A hipertensão arterial é um processo crônico de baixo grau inflamatório, associado com liberação de citocinas e desenvolvimento de lesão em órgãos-alvo. A desregulação dos níveis de proteína quimiotática de monócitos-1 (MCP-1) tem sido associada com elevação da press

  17. A 30 ps Timing Resolution for Single Photons with Multi-pixel Burle MCP-PMT

    Energy Technology Data Exchange (ETDEWEB)

    Va' vra, J.; Benitez, J.; Coleman, J.; Leith, D.W.G.S.; Mazaheri, G.; Ratcliff, B.; Schwiening, J.; /SLAC

    2006-07-05

    We have achieved {approx}30 psec single-photoelectron and {approx}12ps for multi-photoelectron timing resolution with a new 64 pixel Burle MCP-PMT with 10 micron microchannel holes. We have also demonstrated that this detector works in a magnetic field of 15kG, and achieved a single-photoelectron timing resolution of better than 60 psec. The study is relevant for a new focusing DIRC RICH detector for particle identification at future Colliders such as the super B-factory or ILC, and for future TOF techniques. This study shows that a highly pixilated MCP-PMT can deliver excellent timing resolution.

  18. Thermal neutron imaging using microchannel plates

    Science.gov (United States)

    Fraser, George W.; Pearson, James F.; Al-Horayess, O. S.; Feller, W. Bruce; Cook, Lee M.

    1993-02-01

    Microchannel plates (MCPs) are compact electron multipliers of high gain, widely used for the high resolution imaging of charged particles and photons. In this paper, we consider the use of lead glass MCPs for the imaging of thermal neutrons. Two contrasting techniques are described. The first method involves direct neutron detection within a special channel plate structure containing lithium and/or boron. We review the constraints of glass chemistry on the attainable lithium oxide and boron oxide fractions and, hence, on the maximum neutron detection efficiency. The second method involves the detection, using MCPs of standard glass composition, of the internal conversion electrons from a thin gadolinium foil. We present the first measurements of the detection efficiency, pulse height resolution and imaging properties of a pulse-counting MCP/Gd detector system.

  19. Research Progress in Performance and Molding Technology of Polymer Sandwich Plates%聚合物夹层复合板材性能及成型技术研究进展

    Institute of Scientific and Technical Information of China (English)

    周翔; 蒋金云; 薛平; 贾明印; 陈同海

    2014-01-01

    夹层复合板是一种高强轻质的复合板材。主要包括蜂窝夹层结构与泡沫夹层结构。夹层复合板材广泛应用于航空航天领域。早期的夹层板材以金属材料为主。随着聚合物工业的加速发展,聚合物材料以及纤维增强聚合物也成为夹层复合板材的主要材料。主要介绍各种以聚合物为原材料制成的蜂窝夹层板材和泡沫夹层板材的性能、成型技术和应用领域。%The sandwich plate is a kind of high strength and lightweight composite plate. It mainly includes the honeycomb sandwich structure and the foam sandwich structure, and is widely used in aerospace field. Early sandwich plate is given priority to with metal material. With the accelerating development of polymer industry, polymer materials and fiber reinforced polymer has became the main material of sandwich plate. In this paper, performance, molding technology and application of the honeycomb sandwich plate and foam sandwich plate made from various polymer materials were introduced.

  20. Development and testing of cost-effective, 6 cm×6 cm MCP-based photodetectors for fast timing applications

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jingbo, E-mail: wjingbo@anl.gov [High Energy Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Byrum, Karen; Demarteau, Marcel [High Energy Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Elam, Jeffrey; Mane, Anil [Energy Systems Division, Argonne National Laboratory, Argonne, IL 60439 (United States); May, Edward; Wagner, Robert; Walters, Dean; Xia, Lei; Xie, Junqi; Zhao, Huyue [High Energy Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2015-12-21

    Micro-channel plate (MCP)-based photodetectors are capable of picosecond level time resolution and sub-mm level position resolution, which makes them a perfect candidate for the next generation large area photodetectors. The large-area picosecond photodetector (LAPPD) collaboration is developing new techniques for making large-area photodetectors based on new MCP fabrication and functionalization methods. A small single tube processing system (SmSTPS) was constructed at Argonne National Laboratory (ANL) for developing scalable, cost-effective, glass-body, 6 cm×6 cm, picosecond photodetectors based on MCPs functionalized by Atomic Layer Deposition (ALD). Recently, a number of fully processed and hermitically sealed prototypes made of MCPs with 20 μm pores have been fabricated. This is a significant milestone for the LAPPD project. These prototypes were characterized with a pulsed laser test facility. Without optimization, the prototypes have shown excellent results: the time resolution is ~57 ps for single photoelectron mode and ~15 ps for multi-photoelectron mode; the best position resolution is ≤0.8 mm for large pulses. In this paper, the tube processing system, the detector assembly, experimental setup, data analysis and the key performance will be presented.

  1. Identification of the mcpA and mcpM Genes, Encoding Methyl-Accepting Proteins Involved in Amino Acid and l-Malate Chemotaxis, and Involvement of McpM-Mediated Chemotaxis in Plant Infection by Ralstonia pseudosolanacearum (Formerly Ralstonia solanacearum Phylotypes I and III)

    Science.gov (United States)

    Hida, Akiko; Oku, Shota; Kawasaki, Takeru; Tajima, Takahisa

    2015-01-01

    Sequence analysis has revealed the presence of 22 putative methyl-accepting chemotaxis protein (mcp) genes in the Ralstonia pseudosolanacearum GMI1000 genome. PCR analysis and DNA sequencing showed that the highly motile R. pseudosolanacearum strain Ps29 possesses homologs of all 22 R. pseudosolanacearum GMI1000 mcp genes. We constructed a complete collection of single mcp gene deletion mutants of R. pseudosolanacearum Ps29 by unmarked gene deletion. Screening of the mutant collection revealed that R. pseudosolanacearum Ps29 mutants of RSp0507 and RSc0606 homologs were defective in chemotaxis to l-malate and amino acids, respectively. RSp0507 and RSc0606 homologs were designated mcpM and mcpA. While wild-type R. pseudosolanacearum strain Ps29 displayed attraction to 16 amino acids, the mcpA mutant showed no response to 12 of these amino acids and decreased responses to 4 amino acids. We constructed mcpA and mcpM deletion mutants of highly virulent R. pseudosolanacearum strain MAFF106611 to investigate the contribution of chemotaxis to l-malate and amino acids to tomato plant infection. Neither single mutant exhibited altered virulence for tomato plants when tested by root dip inoculation assays. In contrast, the mcpM mutant (but not the mcpA mutant) was significantly less infectious than the wild type when tested by a sand soak inoculation assay, which requires bacteria to locate and invade host roots from sand. Thus, McpM-mediated chemotaxis, possibly reflecting chemotaxis to l-malate, facilitates R. pseudosolanacearum motility to tomato roots in sand. PMID:26276117

  2. Research of MCP-1 expression in rat's retina injured by ischemia-reperfusion%MCP-1在大鼠视网膜缺血再灌注损伤中的表达及意义研究

    Institute of Scientific and Technical Information of China (English)

    游志鹏; 姜德咏; 李国栋; 赵宏伟

    2003-01-01

    目的了解MCP-1在大鼠视网膜缺血再灌注损伤中的表达及意义.方法建立大鼠视网膜缺北血再灌注模型,以SABC法检测MCP-1在视网膜中的表达,统计学分析.结果MCP-1在视网膜缺血再灌注6 h开始表达,第24小时达到最高峰,48 h开始表达减弱.结论MCP-1在视网膜缺血再灌注损伤中起重要作用.%Objective:The retina ischemia- reperfusion injury is caused by many factors. A lot of cell factors take part in it. Many researches suggest MCP - 1 has special effect on leukocyte and lymphocyte. The research try to study the effect of MCP - 1 in rat's retina ischemia- reperfusion injury. Methods: To employ the rat's retina ischemia- reperfusion model and use SABC method to test the expression of MCP- 1 on retina. Results: There was no MCP - 1 expressed in retina after ischemia- reperfusion injury for one hour. MCP- 1 began to express in retina after ischemia- reperfusion injury for six hours, and expressed at most after ischemia- reperfusion injury for 24 hours. Then it began to decrease in 48 hours after ischemia - repeffusion injury, but it still expressed in retina in seventy- two hours after ischemia- reperfusion injury. Conclusions: MCP- 1 plays an important role in rat's retina ischemia- reperfusion injury.

  3. A high resolution, high frame rate detector based on a microchannel plate read out with the Medipix2 counting CMOS pixel chip.

    CERN Document Server

    Mikulec, Bettina; McPhate, J B; Tremsin, A S; Siegmund, O H W; Clark, Allan G; CERN. Geneva

    2005-01-01

    The future of ground-based optical astronomy lies with advancements in adaptive optics (AO) to overcome the limitations that the atmosphere places on high resolution imaging. A key technology for AO systems on future very large telescopes are the wavefront sensors (WFS) which detect the optical phase error and send corrections to deformable mirrors. Telescopes with >30 m diameters will require WFS detectors that have large pixel formats (512x512), low noise (<3 e-/pixel) and very high frame rates (~1 kHz). These requirements have led to the idea of a bare CMOS active pixel device (the Medipix2 chip) functioning in counting mode as an anode with noiseless readout for a microchannel plate (MCP) detector and at 1 kHz continuous frame rate. First measurement results obtained with this novel detector are presented both for UV photons and beta particles.

  4. Involvement of spinal monocyte chemoattractant protein-1 (MCP-1) in cancer-induced bone pain in rats.

    Science.gov (United States)

    Hu, Ji-Hua; Zheng, Xiao-Yan; Yang, Jian-Ping; Wang, Li-Na; Ji, Fu-Hai

    2012-05-23

    In this study, we examined the involvement of chemokine monocyte chemoattractant protein-1 (MCP-1) in the spinal cord of a rat model of cancer-induced bone pain (CIBP). In this model, CIBP was established by an intramedullary injection of Walker 256 cells into the tibia of rats. We observed a significant increase in expression levels of MCP-1 and its receptor CCR2 in the spinal cord of CIBP rats. Furthermore, the intrathecal administration of an anti-MCP-1 neutralizing antibody attenuated the mechanical allodynia established in CIBP rats. Likewise, an intrathecal injection of exogenous recombinant MCP-1 induced a striking mechanical allodynia in naïve rats. These results suggest that increases in spinal MCP-1 and CCR2 expression are involved in the development of mechanical allodynia associated with bone cancer rats.

  5. Sensory Quality of ‘Cherry’ Tomatoes in Relation to 1-MCP Treatment and Storage Duration

    Directory of Open Access Journals (Sweden)

    Marek GAJEWSKI

    2014-06-01

    Full Text Available 1-MCP (1-methylcyclopropene, the ethylene receptors blocker, is used in horticultural practice for prolonging ‘shelf-life’ of several species of fruits and vegetables. The objective of this study was to determine the effect of 1-MCP treatment on sensory characteristics of ‘cherry’ type tomatoes (Solanum lycopersicum L. var. cerasiforme after 4-week storage. In the experiment the fruits were harvested at pink and light-red fruit stages (3rd and 5th stage, according to USDA classification, and stored for 3 and 4 weeks at 12 oC, then moved to 20  sup>oC for 2 days to obtain marketable maturity. 1-MCP was applied after harvest in concentration of 1 ppm, for 12 hours at 18 oC. The plants belonging to the ‘Dasher F1’ cultivar were grown in a greenhouse in rockwool slabs and fruits were harvested in June. Sensory analysis was performed in expert panel with Quantitative Descriptive Analysis (QDA, using 12 sensory descriptors concerning smell, taste, flavour and texture of the fruits. Also semi-consumer test of liking was carried out. As the control freshly harvested red fruits at optimal consumer's maturity were used. The 1-MCP treated fruits harvested in the light-red stage were of better sensory quality than the untreated ones, similar to freshly harvested, but in the case of the pink fruits, the quality was rated lower. It can be concluded that 1-MCP treatment was effective in delaying ripening of the fruits by better keeping their firmness and colour, however in the case of fruits harvested in earlier stage, overall sensory quality and consumer acceptance was scored lower than for the freshly harvested ones, mainly due to more intensive sour taste and lower sweetness.

  6. Evaluation of the reactivity of sera from patients with systemic lupus erythematosus against the human MCP1.

    Science.gov (United States)

    Bronze-da-Rocha, Elsa; Nóvoa, Ana; Teixeira, Natércia; Vasconcelos, Carlos Silva; Cerveira, Conceição; Castro e Melo, João; Carvalho, Manuel Cirne

    2012-08-01

    This study evaluates metaphase chromosome protein 1 (MCP1), a nuclear antigen, as a diagnostic marker for systemic lupus erythematosus (SLE). Reactivity of sera from 114 Portuguese patients with autoimmune rheumatic disease or from healthy blood donors (HBD), against MCP1, produced in bacteria (bact-MCP1) or in its native form (native-MCP1), was determined by immunoblotting. Predictive and discriminative power of MCP1 reactivity for SLE diagnosis in disease-control groups was evaluated by logistic regression, its diagnostic value determined by receiver-operating characteristic analysis and compared with similar analysis of antinuclear antibody and double-stranded DNA (dsDNA). We demonstrated that native-MCP1, in contrast to bact-MCP1, reacts with SLE sera with significant predictive and discriminative power versus other autoimmune diseases (odds ratio [OR] ≤3.537 and ≥3.265; area under the receiver-operating characteristic curve [AUC] ≤0.643 and ≥0.636) or versus HBD (OR = 5.006; AUC = 0.671), showing a good diagnostic power with high specificity (82.1% versus HBD) and low sensitivity for SLE, similar to those of dsDNA. The reactivity of SLE sera with native-MCP1 was shown to be dependent on the presence of phosphorylated residues. Native-MCP1 was shown to have diagnostic value as a specific marker for SLE diagnosis and, therefore, is a suitable substrate for a new antibody test. The widely reported importance of phosphorylated epitopes as targets for autoantibodies in SLE could also be confirmed for native-MCP1.

  7. Application of MCP2515 in TTCAN Level 1 Node%MCP2515在TTCAN协议Level 1节点中应用

    Institute of Scientific and Technical Information of China (English)

    孟庆栋; 张凤登; 刘荣鹏

    2007-01-01

    TCAN是基于CAN的时间触发的高层协议,具有确定性行为,因而适用于安全相关的场合.本文首先从参照时间、基本周期、系统信息阵、网络时间单元和全局时间五个方面对TTCAN协议进行分析,其后讲解了基于MCP2515的一个TTCAN协议Level 1节点的实现方案.

  8. X-ray focusing with Wolter microchannel plate optics

    CERN Document Server

    Price, G J; Beijersbergen, M W; Fraser, G W; Bavdaz, M; Boutot, J P; Fairbend, R; Flyckt, S O; Peacock, A; Tomaselli, E

    2002-01-01

    Square-pore microchannel plate (MCP) X-ray optics of the 'lobster-eye' geometry have frequently been described in the literature. We have now investigated the use of a radial channel packing geometry which, in the context of an MCP pair slumped to the correct radii of curvature, can form a conic approximation to the Wolter Type I grazing incidence X-ray optic. Such an optic can provide a large effective area with very low mass and may be ideally suited for use in applications such as planetary imaging X-ray fluorescence. We present here the results of X-ray illumination of the first such optic, fabricated by Photonis SAS, France.

  9. Decreased Motor Neuron Support by SMA Astrocytes due to Diminished MCP1 Secretion.

    Science.gov (United States)

    Martin, Jasmin E; Nguyen, TrangKimberly T; Grunseich, Christopher; Nofziger, Jonathan H; Lee, Philip R; Fields, Douglas; Fischbeck, Kenneth H; Foran, Emily

    2017-05-24

    Spinal muscular atrophy (SMA) is an autosomal-recessive disorder characterized by severe, often fatal muscle weakness due to loss of motor neurons. SMA patients have deletions and other mutations of the survival of motor neuron 1 (SMN1) gene, resulting in decreased SMN protein. Astrocytes are the primary support cells of the CNS and are responsible for glutamate clearance, metabolic support, response to injury, and regulation of signal transmission. Astrocytes have been implicated in SMA as in in other neurodegenerative disorders. Astrocyte-specific rescue of SMN protein levels has been shown to mitigate disease manifestations in mice. However, the mechanism by which SMN deficiency in astrocytes may contribute to SMA is unclear and what aspect of astrocyte activity is lacking is unknown. Therefore, it is worthwhile to identify defects in SMN-deficient astrocytes that compromise normal function. We show here that SMA astrocyte cultures derived from mouse spinal cord of both sexes are deficient in supporting both WT and SMN-deficient motor neurons derived from male, female, and mixed-sex sources and that this deficiency may be mitigated with secreted factors. In particular, SMN-deficient astrocytes have decreased levels of monocyte chemoactive protein 1 (MCP1) secretion compared with controls and MCP1 restoration stimulates outgrowth of neurites from cultured motor neurons. Correction of MCP1 deficiency may thus be a new therapeutic approach to SMA.SIGNIFICANCE STATEMENT Spinal muscular atrophy (SMA) is caused by the loss of motor neurons, but astrocyte dysfunction also contributes to the disease in mouse models. Monocyte chemoactive protein 1 (MCP1) has been shown to be neuroprotective and is released by astrocytes. Here, we report that MCP1 levels are decreased in SMA mice and that replacement of deficient MCP1 increases differentiation and neurite length of WT and SMN-deficient motor-neuron-like cells in cell culture. This study reveals a novel aspect of astrocyte

  10. Toward a noncytotoxic glioblastoma therapy: blocking MCP-1 with the MTZ Regimen

    Directory of Open Access Journals (Sweden)

    Salacz ME

    2016-04-01

    Full Text Available Michael E Salacz,1,2 Richard E Kast,3 Najmaldin Saki,4 Ansgar Brüning,5 Georg Karpel-Massler,6 Marc-Eric Halatsch6 1Department of Internal Medicine, 2Department of Neurosurgery, University of Kansas, Kansas City, KS, USA; 3IIAIGC Study Center, Burlington, VT, USA; 4Health Research Institute, Research Center of Thalassemia and Hemoglobinopathy, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran; 5Molecular Biology Laboratory, University Hospital Munich, Munich, Germany; 6Department of Neurosurgery, University of Ulm, Ulm, Germany Abstract: To improve the prognosis of glioblastoma, we developed an adjuvant treatment directed to a neglected aspect of glioblastoma growth, the contribution of nonmalignant monocyte lineage cells (MLCs (monocyte, macrophage, microglia, dendritic cells that infiltrated a main tumor mass. These nonmalignant cells contribute to glioblastoma growth and tumor homeostasis. MLCs comprise of approximately 10%–30% of glioblastoma by volume. After integration into the tumor mass, these become polarized toward an M2 immunosuppressive, pro-angiogenic phenotype that promotes continued tumor growth. Glioblastoma cells initiate and promote this process by synthesizing 13 kDa MCP-1 that attracts circulating monocytes to the tumor. Infiltrating monocytes, after polarizing toward an M2 phenotype, synthesize more MCP-1, forming an amplification loop. Three noncytotoxic drugs, an antibiotic – minocycline, an antihypertensive drug – telmisartan, and a bisphosphonate – zoledronic acid, have ancillary attributes of MCP-1 synthesis inhibition and could be re-purposed, singly or in combination, to inhibit or reverse MLC-mediated immunosuppression, angiogenesis, and other growth-enhancing aspects. Minocycline, telmisartan, and zoledronic acid – the MTZ Regimen – have low-toxicity profiles and could be added to standard radiotherapy and temozolomide. Re-purposing older drugs has advantages of established safety and low

  11. Influência do 1-MCP na conservação pós-colheita de rosas cv. Vega Influence of 1-MCP on postharvest conservation of roses cv. Vega

    Directory of Open Access Journals (Sweden)

    Júlia De Pietro

    2010-10-01

    Full Text Available Objetivou-se, neste trabalho, estudar aspectos da fisiologia pós-colheita de rosas cortadas cv. Vega, tratadas com diferentes concentrações de 1-metilcicloropropeno (1-MCP. O experimento foi conduzido em delineamento inteiramente casualizado, em esquema fatorial composto por dois fatores: quatro tratamentos pós-colheita e quatro datas de avaliação (0; 4; 8; 12 dias. As flores foram submetidas aos seguintes tratamentos: 1 Água destilada (controle; 2 1-MCP (100 ppb; 3 1-MCP (250 ppb; 4 1-MCP (500 ppb. Foram realizadas as seguintes avaliações: massa fresca, cor, turgescência, curvatura, taxa respiratória, conteúdo relativo de água, conteúdo de carboidratos solúveis, de redutores e de antocianina. Ao contrário do tratamento controle, todas as concentrações de 1-MCP foram eficientes para retardar a senescência das flores, porém, a concentração de 1-MCP a 500 ppb destacou-se pela melhor manutenção da qualidade, além de prolongar a vida decorativa das hastes até 19 dias.The objective of this work was to study aspects of postharvest physiology of cut roses cv. Vega, treated with different concentrations of 1-metilcloropropene (1-MCP. The experiment was conducted in a complete randomized design composed of two factors: four postharvest treatments and four dates of evaluation (0; 4; 8; 12 days. The following treatments were used: 1 distilled water; 2 1-metilciclopropeno (1-MCP 100 ppb; 3 1-MCP 250 ppb; 4 1-MCP 500 ppb. The following evaluations were made: fresh weight, color, turgor, curvature, respiration rate, relative water content, content of soluble carbohydrates, reducing and anthocyanin. Unlike treatment with distilled water, all concentrations of 1-MCP were effective in delaying the senescence of flowers; however, the concentration of 1-MCP at 500 ppb was highlighted by better maintenance of quality and extended decorate life stem up to 19 days.

  12. Collaborative guarded-hot-plate tests between the Laboratoire national de métrologie et d’essais and the National Institute of Standards and Technology

    Science.gov (United States)

    Zarr, Robert R.; Guthrie, William F.; Hay, Bruno; Koenen, Alain

    2017-02-01

    A collaborative study to compare the long-term measurement performance between guarded-hot-plate facilities at the Laboratoire national de métrologie et d’essais (LNE) in France and the National Institute of Standards and Technology (NIST) in the United States is presented. Thermal conductivity data were compiled from three international comparisons organized from 1997 to 2014. Measurements were conducted in accordance with standardized test methods (ISO 8302 or ASTM C 177) over a temperature range from 280 K to 320 K. Nine thermal insulating materials (either mineral fiber or expanded polystyrene) were examined covering broad ranges of bulk densities (13 kg · m-3-200 kg · m-3) and thicknesses (13 mm-70 mm). A different set of specimens was utilized for each comparison. Results of this study indicate that, over a 17 year interval, the majority of test data from LNE and NIST agreed to within  ±1.0%, or less, for mineral fiber materials and to within  ±0.5%, or less, for expanded polystyrene. The long-term variability limit of 1% between the two laboratories is in good agreement with their current measurement uncertainties. Regression coefficients and their standard uncertainties for a straight-line model relating thermal conductivity to temperature from 280 K to 320 K were computed by material and laboratory. Graphical analysis of the data and corresponding fits exhibit consistent behavior by material type between the two laboratories. Sources of measurement variability are addressed.

  13. Effect of acidosis on IL-8 and MCP-1 during hypoxia and reoxygenation in human NT2-N neurons.

    Science.gov (United States)

    Frøyland, Elisabeth; Pedersen, Elena Didenko; Kvissel, Anne-Katrine; Almaas, Runar; Pharo, Anne; Skålhegg, Bjørn Steen; Mollnes, Tom Eirik; Rootwelt, Terje

    2006-10-03

    Inflammation probably plays a significant role in perinatal brain injury. To study the contribution of locally produced cytokines, the effect on cell death of addition of IL-8 and MCP-1 or antibodies to these, and the impact of acidosis, human postmitotic NT2-N neurons were exposed to 3 h of hypoxia and glucose deprivation and reoxygenated for 21 h. After 3 h of hypoxia with neutral medium, IL-8 was significantly increased compared to controls (150 (100-250)% vs. 100 (85-115)%, p=0.023). After 21 h of neutral reoxygenation, both IL-8 (380 (110-710)% vs. 150 (85-260)%, p=0.041) and monocyte chemoattractant protein-1 (MCP-1) (650 (440-2000)% vs. 310 (230-340)%, p=0.007) were significantly increased compared to controls. After 3 h of hypoxia, both IL-8 (p=0.002) and MCP-1 (p=0.008) were significantly lower in cells with acidotic compared with cells with neutral medium. Acidosis during reoxygenation, however, significantly increased IL-8 release, whereas MCP-1 release was diminished. Similar effects of acidosis were seen in normoxic controls. The cells also secreted RANTES and IP-10, but not 8 other cytokines tested. We found no effect on cell death, measured by MTT assay, of addition of IL-8, MCP-1 or antibodies to these. We conclude that human NT2-N neurons release IL-8 and MCP-1 during 21 h of reoxygenation after 3 h of hypoxia. Acidosis led to a differential effect on IL-8 and MCP-1, with increased IL-8 and decreased MCP-1, both during reoxygenation and in normoxic controls. IL-8 and MCP-1 had no effect on cell death.

  14. Progress towards a 256 channel multi-anode microchannel plate photomultiplier system with picosecond timing.

    Science.gov (United States)

    Lapington, J S; Ashton, T J R; Ross, D; Conneely, T

    2012-12-11

    Despite the rapid advances in solid state technologies such as the silicon photomultiplier (SiPM), microchannel plate (MCP) photomultipliers still offer a proven and practical technological solution for high channel count pixellated photon-counting systems with very high time resolution. We describe progress towards a 256 channel optical photon-counting system using CERN-developed NINO and HTDC ASICs, and designed primarily for time resolved spectroscopy in life science applications. Having previously built and demonstrated a 18 mm diameter prototype tube with an 8×8 channel readout configuration and <43 ps rms single photon timing resolution, we are currently developing a 40 mm device with a 32×32 channel readout. Initially this will be populated with a 256 channel electronics system comprising four sets of modular 64 channel preamplifier/discriminator, and time-to-digital converter units, arranged in a compact three dimensional configuration. We describe the detector and electronics design and operation, and present performance measurements from the 256 channel development system. We discuss enhancements to the system including higher channel count and the use of application specific on-board signal processing capabilities.

  15. Create Your Plate

    Medline Plus

    Full Text Available ... A A A Listen En Español Create Your Plate Create Your Plate is a simple and effective ... and that your options are endless. Create Your Plate! Click on the plate sections below to add ...

  16. Conservação da qualidade de caqui 'Fuyu' em ambiente refrigerado pela combinação de 1-MCP e atmosfera modificada Quality maintenance of 'Fuyu' persimmon in cold storage by combining 1-MCP and modified atmosphere

    Directory of Open Access Journals (Sweden)

    Luiz Carlos Argenta

    2009-06-01

    Full Text Available O presente estudo analisou os efeitos do inibidor da ação do etileno 1-MCP (1-metilciclopropeno, da AM (atmosfera modificada e do oxidante de etileno KMnO4 (permanganato de potássio sobre a qualidade de caqui 'Fuyu' após a armazenagem refrigerada. Os fatores 1-MCP, AM e KMnO4 foram combinados de quatro maneiras, correspondendo aos seguintes tratamentos: T1 Controle + AM + KMnO4;T2 1-MCP + AM + KMnO4; T3 1-MCP + AM, e T4 1-MCP + AA (AA=atmosfera do ar. Frutos maduro-firmes com coloração da casca predominantemente amarela foram colhidos em sete pomares comerciais no nordeste do Estado do Rio Grande do Sul. Parte dos frutos foi exposta a 0.3 µL L-1 de 1-MCP por 12 h em 24 h após a colheita. A seguir, os frutos foram armazenados sob AA ou sob AM induzida por bolsas de polietileno (0,04 mm de espessura, por 20; 40; 60 ou 80 dias a -0,1±0,8ºC. Dois sachês contendo 8,5 g de Alumina-KMnO4foram adicionados em cada uma das bolsas de polietileno dos tratamentos um e dois, antes de elas serem vedadas. Os frutos de cada período de armazenagem refrigerada foram analisados após 0; 3; 6 ou 9 dias de prateleira sob AA a 22±1ºC. O tratamento 1-MCP retardou o amolecimento da polpa, mas não afetou consistentemente o desenvolvimento de 'estrias' e manchas pretas na superfície dos frutos armazenados sob AM contendo KMnO4. A incidência de 'estrias' e manchas pretas em frutos tratados com 1-MCP e armazenados sob AM foi significativamente menor que a de frutos tratados com 1-MCP e armazenados sob AA. Houve efeitos aditivos do 1-MCP e AM na conservação da firmeza e na redução de danos por frio manifestados pela formação de textura gel-firme e manchas translúcidas na casca. O uso de KMnO4 não aumentou a conservação da qualidade dos frutos quando tratados com 1-MCP e armazenados sob AM. O desenvolvimento dos distúrbios da epiderme dependeu do pomar e de períodos de armazenagem e prateleira. No entanto, os benefícios da combinação de 1-MCP e

  17. CAN控制器芯片MCP2510在远程监测系统中的应用

    Institute of Scientific and Technical Information of China (English)

    王继国; 孙新亚

    2004-01-01

    介绍了CAN控制器芯片MCP2510的功能、结构和工作原理,提出了一种利用MCP2510芯片和MSP430单片机组成远程监测系统的方案,并通过硬件电路和软件的实现证明了其可行性和正确性,同时列举了MCP2510在使用中的一些注意事项.

  18. Position sensitive anodes for MCP read-out using induced charge measurement

    CERN Document Server

    Jagutzki, O; Mergel, V; Schmidt-Böcking, H; Spillmann, U; Worth, L B C

    2002-01-01

    We investigate the method of an indirect detection of a MCP charge avalanche projected onto a resistive layer (G. Battistoni, et al., Nucl. Instr. and Meth., 202 (1982) 459). If the sheet resistance is favourable one can detect the charge cloud by the capacitive coupling to an anode structure a few millimetres behind the layer. The anode structure can be, for example, a wedge-and-strip electrode pattern (M. Unverzagt, Diplomarbeit, Universitaet Frankfurt 1992, private communication) as it is used for directly collecting the electron avalanche from a MCP. Detection of the induced charge is beneficial in several respects. Firstly, image distortions produced by secondary electron mediated charge redistribution are eliminated. Secondly, the noise component due to quantized charge collection, commonly referred to as partition noise, is not present. In addition, the dielectric substrate can function both as an element of the vacuum enclosure and HV insulator, making the electrical connections easily accessible and ...

  19. EFECTO DEL 1-METIL-CICLOPROPENO (1-MCP EN LA MADURACIÓN DE BANANO

    Directory of Open Access Journals (Sweden)

    Kattia Chang-Yuen

    2005-01-01

    Full Text Available Se evaluó la eficacia del 1-metil-ciclopropeno (1-MCP en la maduración del banano (Musa sp Cavendish, aplicado después del empaque en fruta para el mercado de EE.UU. y Europa. Se utilizó fruta de 3 diferentes compañías bananeras; la fruta fue expuesta a 0, 20 y 30 nl l-1 de 1-MCP, por 24 h. Posteriormente, fue sometida a simulación de transporte, según el mercado de destino (7 días EE.UU. y 15 días Europa. Finalizada la simulación se indujo el proceso de maduración con etileno. Las evaluaciones se realizaron cada 2 días, e incluyeron análisis de calidad externa (enfermedades poscosecha y desarrollo de color externo de la cáscara y de calidad interna (oBrix, firmeza, porcentaje de acidez titulable y tasa de produc ción de CO2. Una aplicación de 30 nl l-1 de 1-MCP, generó una ganancia de más de 4 días de vida de anaquel por encima de la fruta control.La apariencia externa y la calidad interna de la fruta no se vio afectada de forma negativa por la exposición al 1-MCP, aunque se recomienda realizar pruebas sensoriales con consumidores en los mercados de destino.

  20. Study on Fresh-keeping of Strawberry by Using 1-MCP-β-cyclodextrin%1-MCP-β-环糊精对草莓保鲜的应用研究

    Institute of Scientific and Technical Information of China (English)

    何飞

    2011-01-01

    研究了在7 m3密闭体积中用10 mg.L-1 1-MCP-β-环糊精溶液对草莓的保鲜效果。分别测定贮存过程中草莓的感官指标、失重率、总酸含量、可溶性糖含量及维生素C含量含量的变化。结果表面1-MCP-β-环糊精保鲜效果良好。%The effect of 1-MCP-β-cyclodextrin on the preservation of strawberry was studied.The changes in the organoleptic target,weight-loss rate,total acid,content of soluble saccharide and the content of the vitamin C of strawberry were determined during storage.The result indicated that the preservative effect of 1-MCP-β-cyclodextrin was remarkable.

  1. Qualidade de caqui 'Rama forte' após armazenamento refrigerado, influenciada pelos tratamentos 1-MCP e/ou CO2 Quality of 'Rama Forte' perssimon following cold torage influenced by 1-MCP and/or CO2treatments

    Directory of Open Access Journals (Sweden)

    João Peterson Pereira Gardin

    2012-12-01

    Full Text Available Avaliaram-se os efeitos dos tratamentos com CO2 e 1-MCP (1-metilciclopropeno sobre a adstringência (índice de tanino, firmeza da polpa e distúrbios da epiderme em caqui 'Rama Forte'. Frutos foram tratados com 1-MCP por 24 h, logo após a colheita e/ou com alto CO2 (70% por 24 ou 48 h, um dia após a colheita ou após o armazenamento refrigerado (AR. Os caquis foram armazenados sob atmosfera modificada a 0 ºC, por 45 dias, e a seguir mantidos a 23 ºC, por 9 dias. Frutos-controle (não tratados com 1-MCP nem com CO2 amoleceram em três dias e perderam aproximadamente 50% da adstringência em 6 dias após o AR. A exposição ao CO2 acelerou a redução da adstringência. Esse efeito do CO2 foi menor em frutos tratados com 1-MCP, especialmente quando o CO2 foi aplicado após o AR, por apenas 24 h. O tratamento com 1-MCP inibiu o amolecimento e a redução da adstringência, especialmente nos frutos não tratados com CO2. O amolecimento de frutos tratados com 1-MCP foi maior quando a exposição ao CO2 ocorreu antes do AR. A combinação dos tratamentos com 1-MCP e alto CO2 reduziu a incidência de podridões e manchas translúcidas, mas não alterou o desenvolvimento de pintas pretas ('estrias'. Os resultados indicam que é possível induzir perda da adstringência sem excessiva perda da firmeza da polpa de caquis 'Rama Forte' após o AR pela associação dos tratamentos com 1-MCP logo após a colheita e alto CO2 após o AR.This study evaluated the effects of CO2 and 1-MCP (1-methylcyclopropene treatments on astringency (tannin index, flesh firmness and skin disorders on 'Rama Forte' persimmon. Fruit were treated with 1-MCP for 24 h right after harvest and/or with high CO2 (70% CO2 balanced with air for 24 or 48 h, one day after harvest or after cold storage (CS. Fruit were stored in modified atmosphere for 45 days at 0ºC and then held at 23ºC for 9 days. Control fruit (untreated with neither 1-MCP nor CO2 softened in 3 days and lost about 50

  2. Evaluating the potential of IP-10 and MCP-2 as biomarkers for the diagnosis of TB

    DEFF Research Database (Denmark)

    Ruhwald, Morten; Bodmer, T; Maier, C

    2008-01-01

    were obtained from 80 patients with culture and/or PCR proven TB, and 124 unexposed healthy controls; 86 high school students and 38 high school staff. IP-10 and MCP-2 test cut-offs were established based on ROC curve analysis.TB patients produced significantly higher levels of IP-10 (median 2158 pg.......ml(-1)) and MCP-2 (median 379 pg.ml(-1)) compared with IFN-gamma (median 215 pg.ml(-1), pTB patients; 0%, 3% and 0% of the high school students and 0%, 16%; and 3% of the staff. Agreement between tests was high >89% (kappa>0.......77). By combining IP-10 and IFN-gamma tests the detection rate increased among TB patients to 90% without a significant increase in positive responders among the students.In conclusion, IP-10 and MCP-2 responses to M.tuberculosis specific antigens could be used to diagnose infection. Combining IP-10 and IFN...

  3. The cross-validated AUC for MCP-logistic regression with high-dimensional data.

    Science.gov (United States)

    Jiang, Dingfeng; Huang, Jian; Zhang, Ying

    2013-10-01

    We propose a cross-validated area under the receiving operator characteristic (ROC) curve (CV-AUC) criterion for tuning parameter selection for penalized methods in sparse, high-dimensional logistic regression models. We use this criterion in combination with the minimax concave penalty (MCP) method for variable selection. The CV-AUC criterion is specifically designed for optimizing the classification performance for binary outcome data. To implement the proposed approach, we derive an efficient coordinate descent algorithm to compute the MCP-logistic regression solution surface. Simulation studies are conducted to evaluate the finite sample performance of the proposed method and its comparison with the existing methods including the Akaike information criterion (AIC), Bayesian information criterion (BIC) or Extended BIC (EBIC). The model selected based on the CV-AUC criterion tends to have a larger predictive AUC and smaller classification error than those with tuning parameters selected using the AIC, BIC or EBIC. We illustrate the application of the MCP-logistic regression with the CV-AUC criterion on three microarray datasets from the studies that attempt to identify genes related to cancers. Our simulation studies and data examples demonstrate that the CV-AUC is an attractive method for tuning parameter selection for penalized methods in high-dimensional logistic regression models.

  4. Ethylene and 1-MCP regulate major volatile biosynthetic pathways in apple fruit.

    Science.gov (United States)

    Yang, Xiaotang; Song, Jun; Du, Lina; Forney, Charles; Campbell-Palmer, Leslie; Fillmore, Sherry; Wismer, Paul; Zhang, Zhaoqi

    2016-03-01

    The effects of ethylene and 1-methylcyclopropene (1-MCP) on apple fruit volatile biosynthesis and gene expression were investigated. Statistical analysis identified 17 genes that changed significantly in response to ethylene and 1-MCP treatments. Genes encoding branched-chain amino acid aminotransferase (BCAT), aromatic amino acid aminotransferase (ArAT) and amino acid decarboxylases (AADC) were up-regulated during ripening and further enhanced by ethylene treatment. Genes related to fatty acid synthesis and metabolism, including acyl-carrier-proteins (ACPs), malonyl-CoA:ACP transacylase (MCAT), acyl-ACP-desaturase (ACPD), lipoxygenase (LOX), hydroperoxide lyase (HPL), alcohol dehydrogenase (ADH), pyruvate decarboxylase (PDC2), β-oxidation, acyl-CoA synthetase (ACS), enoyl-CoA hydratase (ECHD), acyl-CoA dehydrogenase (ACAD), and alcohol acyltransferases (AATs) also increased during ripening and in response to ethylene treatment. Allene oxide synthase (AOS), alcohol dehydrogenase 1 (ADH1), 3-ketoacyl-CoA thiolase and branched-chain amino acid aminotransferase 2 (BCAT2) decreased in ethylene-treated fruit. Treatment with 1-MCP and ethylene generally produced opposite effects on related genes, which provides evidence that regulation of these genes is ethylene dependent. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  5. Pattern recognition of monocyte chemoattractant protein-1 (MCP-1) in whole blood samples using new platforms based on nanostructured materials

    Science.gov (United States)

    Stefan-van Staden, Raluca-Ioana; Gugoasa, Livia Alexandra; Biris, Alexandru Radu

    2015-09-01

    Four stochastic microsensors based on nanostructured materials (graphene, maltodextrin (MD), and diamond) integrated in miniaturized platforms were proposed. Monocyte chemoattractant protein-1 (MCP-1) is a pro-inflammatory cytokine whose main function is to regulate cell trafficking. It is correlated with the incidence of cardiovascular diseases and obesity, and was used as the model analyte in this study. The screening of whole blood samples for MCP-1 can be done for concentrations ranging from 10-12 to 10-8 g mL-1. The method was used for both qualitative and quantitative assessments of MCP-1 in whole blood samples. The lowest quantification limits for the assay of MCP-1 (1 pg mL-1) were reached when the microsensors based on protoporphyrin IX/Graphene-Au-3 and on MD/Graphene were employed in the platform design.

  6. Non-myeloid Cells are Major Contributors to Innate Immune Responses via Production of Monocyte Chemoattractant Protein- 1(MCP-1/CCL2

    Directory of Open Access Journals (Sweden)

    Teizo eYoshimura

    2014-01-01

    Full Text Available Monocyte chemoattractant protein-1 (MCP-1/CCL2 is a chemokine regulating the recruitment of monocytes into sites of inflammation and cancer. MCP-1 can be produced by a variety of cell types, such as macrophages, neutrophils, fibroblasts, endothelial cells and epithelial cells. Notably, macrophages produce high levels of MCP-1 in response to proinflammatory stimuli in vitro, leading to the hypothesis that macrophages are the major source of MCP-1 during inflammatory responses in vivo. In stark contrast to the hypothesis, however, there was no significant reduction in MCP-1 protein or the number of infiltrating macrophages in the peritoneal inflammatory exudates of myeloid cell-specific MCP-1-deficient mice in response to i.p injection of thioglycollate or zymosan A. Furthermore, injection of LPS into skin air pouch also had no effect on local MCP-1 production in myeloid-specific MCP-1-deficient mice. Finally, myeloid-specific MCP-1-deficiency did not reduce MCP-1 mRNA expression or macrophage infiltration in LPS-induced lung injury. These results indicate that non-myeloid cells, in response to a variety of stimulants, play a previously unappreciated role in innate immune responses as the primary source of MCP-1.

  7. Adipocyte-derived monocyte chemotactic protein-1 (MCP-1) promotes prostate cancer progression through the induction of MMP-2 activity.

    Science.gov (United States)

    Ito, Yusuke; Ishiguro, Hitoshi; Kobayashi, Naohito; Hasumi, Hisashi; Watanabe, Masatoshi; Yao, Masahiro; Uemura, Hiroji

    2015-07-01

    Obesity is known to be associated with prostate cancer development and progression, but the detailed mechanism is not clear. Monocyte chemotactic protein-1 (MCP-1) is secreted from cancer cells, stromal cells, and adipocytes, and it is involved in prostate cancer progression. Here we investigated the biological role of MCP-1 secreted from adipocytes for prostate cancer cells. Human pre-adipocytes (HPAds) were cultured and differentiated to mature adipocytes. Conditioned medium (CM) from HPAd cells was obtained using phenol red-free RPMI1640 medium. We performed a cytokine membrane array analysis to detect cytokines in the CM. To characterize the physiological function of MCP-1 in the CM, we performed an MTT-assay, a wound-healing and invasion assay with anti-MCP-1 antibody using three prostate cancer cell lines: DU145, LNCaP, and PC-3. Matrix metalloproteinase (MMP)-2 and MMP-9 activities were evaluated by gelatin zymography. A qPCR and Western blotting were used to examine the mRNA and protein expression levels of MMP-2. The cytokine membrane array of the CM showed a strong signal of MCP-1compared to the control medium, and we thus focused our attention on MCP-1 in the CM. The CM up-regulated the cancer cell proliferation, and the neutralization by anti-MCP-1 antibody inhibited the proliferative effect of the prostate cancer cell lines. The CM greatly increased the invasive activity in the prostate cancer cell lines, and anti-MCP-1 antibody decreased the invasiveness. Gelatin zymography revealed that the CM markedly enhanced the enzymatic activity of MMP-2, and anti-MCP-1 antibody down-regulated its effect. MMP-2 mRNA expression was undetected and the MMP-2 protein level was unchanged between the control medium and CM in DU145 cells. MCP-1 from adipocytes enhances the growth and invasion activity of prostate cancer cells. The inhibition of MCP-1 derived from adipocytes might be an effective treatment for prostate cancer. © 2015 Wiley Periodicals, Inc.

  8. Effect of pharmacological intervention on MIP-1α, MIP-1β and MCP-1 expression in patients with psoriasis vulgaris

    Institute of Scientific and Technical Information of China (English)

    Yong-Jiang Dai; Yu-Yang Li; Hui-Ming Zeng; Xiong-An Liang; Zhi-Jie Xie; Zhi-Ang Zheng; Qin-Hui Pan; Yi-Xiong Xing

    2014-01-01

    Objective:To detect the expression level of macrophage inflammatory protein-1(MIP-1)α, MIP-1β and monocyte chemoattractant protein-1(MCP-1) in with psoriasis vulgaris and explore the role in the pathogenesis of psoriasis vulgaris.Methods:The level ofMIP-1α,MIP-1β andMCP-1 in peripheral blood from50 patients with psoriasis vulgaris and50 normal controls were measured by enzyme linked immunosorbent assay.The correlation with psoriasis area and severity index(PASI) was analyzed.The level ofMIP-1α,MIP-1β andMCP-1 was compared between psoriasis vulgaris patients at active stage and resting stage.And the change inMIP-1α, MIP-1β andMCP-1 before and after therapy was also observed.Results:The content ofMIP-1α, MIP-1β andMCP-1 in patients with psoriasis vulgaris was(1342.78±210.30),(175.28±28.18) and (266.86±32.75) ng/L, respectively, significantly higher than those in control group(P<0.05).The expression level ofMIP-1α,MIP-1β andMCP-1 in peripheral blood of patients with psoriasis vulgaris was positively correlated withPASI(P<0.01).After acitretin therapy, expression level ofMIP-1α,MIP-1β andMCP-1 in peripheral blood of patients with psoriasis vulgaris was significantly decreased.Conclusions:Chemokine factorMIP-1α,MIP-1β andMCP-1 may be involved in the pathogenesis of psoriasis vulgaris.

  9. Application of a New Material for Cleaner Gold Plating in Gold Plating Technology%清洁镀金新材料在镀金工艺中的应用

    Institute of Scientific and Technical Information of China (English)

    张磊; 胡文成; 马默雷; 张勇强

    2011-01-01

    A new material for cleaner gold plating was introduced. The gold coating was subjected to tests of compactness, solderability, salt spray test, moisture test and thermal shock test, and the testing results all accorded with China National Military Standard and U. S. A. Military Standard. This nonhazardous material can be directly dosed and keep stable performance、 easy maintenance 、low cost of the bath,also can meet governmental regulation of wastewater discharge . So it's a good substitute for KAu(CN)2 in gold plating.%介绍了一种清洁镀金新材料,采用该新材料配制成镀液所得镀金及其合金镀层镀金件在测试的致密性、可焊性、盐雾试验,潮湿及高低温冲击等项目均符合国家军用标准和美国军用标准,镀金液中可直接加入该物质,镀液稳定,易维护,管理成本低、废水可达到国家排放标准,产品不属危险化学品等.完全可替代氰化亚金钾用于镀金及其合金工艺.

  10. A compact immunoassay platform based on a multicapillary glass plate.

    Science.gov (United States)

    Xue, Shuhua; Zeng, Hulie; Yang, Jianmin; Nakajima, Hizuru; Uchiyama, Katsumi

    2014-05-23

    A highly sensitive, rapid immunoassay performed in the multi-channels of a micro-well array consisting of a multicapillary glass plate (MCP) and a polydimethylsiloxane (PDMS) slide is described. The micro-dimensions and large surface area of the MCP permitted the diffusion distance to be decreased and the reaction efficiency to be increased. To confirm the concept of the method, human immunoglobulin A (h-IgA) was measured using both the proposed immunoassay system and the traditional 96-well plate method. The proposed method resulted in a 1/5-fold decrease of immunoassay time, and a 1/56-fold cut in reagent consumption with a 0.05 ng/mL of limit of detection (LOD) for IgA. The method was also applied to saliva samples obtained from healthy volunteers. The results correlated well to those obtained by the 96-well plate method. The method has the potential for use in disease diagnostic or on-site immunoassays.

  11. A Compact Immunoassay Platform Based on a Multicapillary Glass Plate

    Directory of Open Access Journals (Sweden)

    Shuhua Xue

    2014-05-01

    Full Text Available A highly sensitive, rapid immunoassay performed in the multi-channels of a micro-well array consisting of a multicapillary glass plate (MCP and a polydimethylsiloxane (PDMS slide is described. The micro-dimensions and large surface area of the MCP permitted the diffusion distance to be decreased and the reaction efficiency to be increased. To confirm the concept of the method, human immunoglobulin A (h-IgA was measured using both the proposed immunoassay system and the traditional 96-well plate method. The proposed method resulted in a 1/5-fold decrease of immunoassay time, and a 1/56-fold cut in reagent consumption with a 0.05 ng/mL of limit of detection (LOD for IgA. The method was also applied to saliva samples obtained from healthy volunteers. The results correlated well to those obtained by the 96-well plate method. The method has the potential for use in disease diagnostic or on-site immunoassays.

  12. 牙龈卟啉单胞菌侵入对人血管内皮细胞分泌MCP-1影响的研究%Expression of MCP-1 in vascular endothelial cells invaded by Porphyromonas gingivalis

    Institute of Scientific and Technical Information of China (English)

    邓辉; 徐静; 余溢; 欧阳玉玲; 吴亚菲

    2012-01-01

    目的 通过研究牙龈卟啉单胞菌(porphyrmonas gingivalis,P.g)侵入对人脐静脉内皮细胞(human umbilical vein endothelial cell,HUVEC)分泌单核细胞趋化蛋白(MCP-1)的影响,了解P.g对其趋化功能的影响.方法 建立P,g侵入HUVEC的体外模型,采用酶联免疫吸附法( ELISA)研究P.g381和P.g33277菌株侵入HUVEC 6、24 h后的培养上清液中MCP -1浓度.结果 ELISA结果显示当P.g381侵入HUVEC 6、24h和P.g33277侵入HUVEC 6 h时,HUVEC分泌的MCP -1水平升高(P<0.01);P,g33277侵入HUVEC 24 h时,HUVEC分泌的MCP -1水平恢复最初水平(P=0.46);P.g381诱导HUVEC表达MCP -1的水平高于P.g33277 (P <0.01).结论 P.g侵入HUVEC后可促进其表达MCP -1,从而上调其趋化功能,在牙周炎与心血管疾病的相关性中可能发挥作用.%Objective To investigate the expression of monocyte chemoattractanl protein-1 (MCP-1) in human umbilical vein endo-thetial cells ( HUVEC) invaded by porphyrroonas gingivalis (P. g). Methods The models of invasion of P. g into HUVEC were established in vitro. HUVEC were infected with either P. g381 or P. g33277 .then the expression of MCP-1 in supernatant was tested by ELISA. Results The expression of MCP-1 was signicantly upregulated in P. g381 -infected HUVEC at 6h and 24h and in P. g33277-infecled HUVEC at 6h{ P<0.01). The upregulalion ability of P.g381 was significantly greater than P. g33277(P<0.01). Conclusions These data demonstrate that the infection of P. g can increase the expression of MCP-1 and chemolactic function of HDVEC, which may play a role in the relationship between periodontitis and cardiovascular diseases.

  13. 基于车辆牌照图像的识别技术研究%Research on Image Recognition Technology Based on Vehicle License Plate

    Institute of Scientific and Technical Information of China (English)

    石昊苏

    2015-01-01

    This paper,the whole process of vehicle license plate image recognition is discussed in four aspects:preprocessing,vehicle license plate location,character segmentation and character recognition.Through the analysis of the part of the algorithm,the problem of image quality is solved effectively,and the related problems of batch and automatic vehicle license plate recognition are identiifed.%文章讨论了车辆牌照图像识别整个过程的四个环节:预处理、车辆牌照定位、字符分割、字符识别。通过优化改进Canny算法有效地解决了图像质量不足,批量、自动识别车辆牌照的相关问题。

  14. Research Progress in Technology of Non-cyanide Imitation Gold Plating%无氰仿金电镀工艺研究进展

    Institute of Scientific and Technical Information of China (English)

    高鹏; 屠振密

    2012-01-01

    The sorts of non-cyanide imitation gold plating deposit are introduced. The research status of non-cyanide imitation gold plating at home and abroad is reviewed, including pyrophosphate, tartrate, HEDP and some other complexing agent systems. Finally, the development trend of non-cyanide imitation gold plating is prospected.%介绍了无氰仿金镀层的种类,综述了国内外无氰仿金电镀的研究现状,包括焦磷酸盐体系、酒石酸盐体系、HEDP体系以及其他一些配位剂体系.最后对无氰仿金电镀的发展趋势进行了展望.

  15. Characterization of thermal and mechanical properties of polypropylene-based composites for fuel cell bipolar plates and development of educational tools in hydrogen and fuel cell technologies

    Science.gov (United States)

    Lopez Gaxiola, Daniel

    In this project we developed conductive thermoplastic resins by adding varying amounts of three different carbon fillers: carbon black (CB), synthetic graphite (SG) and multi-walled carbon nanotubes (CNT) to a polypropylene matrix for application as fuel cell bipolar plates. This component of fuel cells provides mechanical support to the stack, circulates the gases that participate in the electrochemical reaction within the fuel cell and allows for removal of the excess heat from the system. The materials fabricated in this work were tested to determine their mechanical and thermal properties. These materials were produced by adding varying amounts of single carbon fillers to a polypropylene matrix (2.5 to 15 wt.% Ketjenblack EC-600 JD carbon black, 10 to 80 wt.% Asbury Carbons' Thermocarb TC-300 synthetic graphite, and 2.5 to 15 wt.% of Hyperion Catalysis International's FIBRIL(TM) multi-walled carbon nanotubes) In addition, composite materials containing combinations of these three fillers were produced. The thermal conductivity results showed an increase in both through-plane and in-plane thermal conductivities, with the largest increase observed for synthetic graphite. The Department of Energy (DOE) had previously set a thermal conductivity goal of 20 W/m·K, which was surpassed by formulations containing 75 wt.% and 80 wt.% SG, yielding in-plane thermal conductivity values of 24.4 W/m·K and 33.6 W/m·K, respectively. In addition, composites containing 2.5 wt.% CB, 65 wt.% SG, and 6 wt.% CNT in PP had an in-plane thermal conductivity of 37 W/m·K. Flexural and tensile tests were conducted. All composite formulations exceeded the flexural strength target of 25 MPa set by DOE. The tensile and flexural modulus of the composites increased with higher concentration of carbon fillers. Carbon black and synthetic graphite caused a decrease in the tensile and flexural strengths of the composites. However, carbon nanotubes increased the composite tensile and flexural

  16. A Technology for Gold Plating on Beryllium Bronze Parts%铍青铜零件电镀金工艺

    Institute of Scientific and Technical Information of China (English)

    刘志强

    2011-01-01

    在铍青铜基体上采用镍作为中间层然后镀金是传统的镀覆方法.有些应用场合不允许采用镀镍而直接镀金,必须解决镀层与基体结合力的问题.分析铍青铜的特性和镀金层结合力不良的原因,提出了一种铍青铜直接电镀金的工艺流程和工艺参数,包括热处理疏松氧化层、微腐蚀、除钝化膜、镀金及封闭处理等工序,解决了铍青铜氧化层的去除及镀金层与基体结合力的问题,使产品质量稳定.%The traditional way of electroplating on beryllium bronze substrate use nickel coating as an intermediate layer before gold plating. In some cases, direct gold plating is needed, and the adhesion problem should be resolved. In this paper, the characteristics of beryllium bronze and affecting factor on adhesion were firstly discussed. And then a new gold plating technique on beryllium bronze including process and parameters of heat treatment loosening oxidation layer, micro corrosion, removal of passivation film,gold plating and sealing treatment was put forward. The problems on the removal of oxidation layer and adhesion between gold plating and substrate were resolved, and the gold plating had a stable performance.

  17. 聚氨酯泡沫化学镀镍工艺%Technology of Electroless Nickel Plating on Polyurethane Foam

    Institute of Scientific and Technical Information of China (English)

    龚凡; 马玲俊; 李占双

    2001-01-01

    Technical conditions of electroless nickel plating on polyurethane foam were given in detail in this paper. Solution components and o perating conditions in the process of the removal of oil stain ,the activation and the electroless nickel plating were discussed.%介绍了聚氨酯泡沫化学镀镍的工艺条件,其中包括除油、活化和 化学镀镍溶液的配方及操作条件

  18. Saudi License Plate Recognition Algorithm Based on Support Vector Machine

    Institute of Scientific and Technical Information of China (English)

    Khaled Suwais; Rana Al-Otaibi; Ali Alshahrani

    2013-01-01

    License plate recognition (LPR) is an image processing technology that is used to identify vehicles by their license plates. This paper presents a license plate recognition algorithm for Saudi car plates based on the support vector machine (SVM) algorithm. The new algorithm is efficient in recognizing the vehicles from the Arabic part of the plate. The performance of the system has been investigated and analyzed. The recognition accuracy of the algorithm is about 93.3%.

  19. Two-dimensional visualization of cluster beams by microchannel plates

    Energy Technology Data Exchange (ETDEWEB)

    Khoukaz, A., E-mail: khoukaz@uni-muenster.de; Bonaventura, D.; Grieser, S.; Hergemöller, A.-K.; Köhler, E.; Täschner, A.

    2014-01-21

    An advanced technique for a two-dimensional real time visualization of cluster beams in a vacuum as well as of the overlap volume of cluster beams with particle accelerator beams is presented. The detection system consists of an array of microchannel plates (MCPs) in combination with a phosphor screen which is read out by a CCD camera. This setup together with the ionization of a cluster beam by an electron or ion beam allows for spatial resolved investigations of the cluster beam position, size, and intensity. Moreover, since electrically uncharged clusters remain undetected, the operation in an internal beam experiment opens the way to monitor the overlap region and thus the position and size of an accelerator beam crossing an originally electrically neutral cluster jet. The observed intensity distribution of the recorded image is directly proportional to the convolution of the spatial ion beam and cluster beam intensities and is by this a direct measure of the two-dimensional luminosity distribution. This information can directly be used for the reconstruction of vertex positions as well as for an input for numerical simulations of the reaction zone. The spatial resolution of the images is dominated by the granularity of the complete MCP device and was found to be in the order of σ≈100μm. -- Highlights: • We present a MCP system for a 2D real time visualization of cluster target beams. • With this device the vertex region of storage ring experiments can be investigated. • Time resolved 2D information about the target thickness distribution is accessible. • A spatial resolution of the MCP device of 0.1 mm was achieved. • The presented MCP system also allows for measurements on cluster masses.

  20. Characterization of Thermal and Mechanical Properties of Polypropylene-Based Composites for Fuel Cell Bipolar Plates and Development of Educational Tools in Hydrogen and Fuel Cell Technologies

    Science.gov (United States)

    Lopez Gaxiola, Daniel

    2011-01-01

    In this project we developed conductive thermoplastic resins by adding varying amounts of three different carbon fillers: carbon black (CB), synthetic graphite (SG) and multi-walled carbon nanotubes (CNT) to a polypropylene matrix for application as fuel cell bipolar plates. This component of fuel cells provides mechanical support to the stack,…

  1. 基于 HA LCON 的车牌识别技术研究%Research on license plate recognition technology based on HALCON

    Institute of Scientific and Technical Information of China (English)

    李锦珑; 张维昭; 马宏锋; 刘馨

    2015-01-01

    For the problem of low speed and accuracy of license plate recognition , a new license plate system is designed in this paper . HALCON is used as the core of machine vision and image processing software . The major work includes image acquisition , image preprocessing and the realization of the detection algorithm . Experiments demonstrate that the accuracy of license plate recognition can reach 94.6% during the day . The speed of identification is also improved relatively ,and the average recognition time of each license plate is 40.3 ms .%针对目前车牌识别速度较慢以及识别准确率较低的问题,以 HALCON作为机器视觉和图像处理核心软件,将计算机视觉检测技术应用于车辆牌照的识别,实现了图像采集、预处理和检测.实验结果表明,白天车辆牌照识别准确率达到94.6%;相对于传统方法,识别速度也有所改进,每幅牌照的平均识别时间为40.3 ms .

  2. 代银镀层技术研究进展%Advances in Research on Plating Technology of Substitute for Silver Coating

    Institute of Scientific and Technical Information of China (English)

    王崇蕊; 郝建军; 董春艳; 刘新院

    2011-01-01

    Several plating methods of substitute for Silver coating such as tin electroplating with sulfate electrolyte, Sn-Ce and acid bright Sn-Ce-Bi alloy electroplating were described. Ni-P/Ni-B double-layer electroless plating, and tin electroless plating followed by Sn-Ce-Sb electroplating method were also introduced. The characteristics of these plating methods were briefly summarized, and the developing trends of these methods were put forward.%介绍了几种替代银镀层的镀覆方法,其中有硫酸盐电解液镀锡、电镀锡-铈合金、酸性光亮镀锡-铈-铋合金等.化学镀Ni-P/Ni-B双层合金镀层,电镀和化学镀相结合的方法有化学镀锡和电镀锡-铈-锑合金.并归纳了各种代银镀层方法的特点,指出了代银镀层技术的发展趋势.

  3. Characterization of Thermal and Mechanical Properties of Polypropylene-Based Composites for Fuel Cell Bipolar Plates and Development of Educational Tools in Hydrogen and Fuel Cell Technologies

    Science.gov (United States)

    Lopez Gaxiola, Daniel

    2011-01-01

    In this project we developed conductive thermoplastic resins by adding varying amounts of three different carbon fillers: carbon black (CB), synthetic graphite (SG) and multi-walled carbon nanotubes (CNT) to a polypropylene matrix for application as fuel cell bipolar plates. This component of fuel cells provides mechanical support to the stack,…

  4. Crosstalk between Tumor Cells and Macrophages in Stroma Renders Tumor Cells as the Primary Source of MCP-1/CCL2 in Lewis Lung Carcinoma.

    Science.gov (United States)

    Yoshimura, Teizo; Liu, Mingyong; Chen, Xin; Li, Liangzhu; Wang, Ji Ming

    2015-01-01

    The chemokine MCP-1/CCL2 is produced by a variety of tumors and plays an important role in cancer progression. We and others previously demonstrated that the primary source of MCP-1 in several mouse tumors, including 4T1 breast cancer, M5076 sarcoma, and B16 melanoma, was stromal cells. In the present study, we identified that tumor cells were the primary source of MCP-1 in Lewis lung carcinoma (LLC), because MCP-1 mRNA was highly expressed in tumors grown in both wild type (WT) and MCP-1(-/-) mice with elevated serum MCP-1 levels. Since LLC cells isolated from tumors expressed low levels of MCP-1 in vitro, it appeared that the tumor-stromal cell interaction in a tumor microenvironment increased MCP-1 expression in LLC cells. In fact, co-culture of LLC cells with normal mouse peritoneal macrophages or normal lung cells containing macrophages increased MCP-1 expression by LLC cells. Macrophages from TNFα(-/-) mice failed to activate LLC cells and anti-TNFα neutralizing antibody abolished the effect of WT macrophages on LLC cells. When LLC cells were transplanted into TNFα(-/-) mice, the levels of MCP-1 mRNA in tumors and serum MCP-1 levels were markedly lower as compared to WT mice, and importantly, tumors grew more slowly. Taken together, our results indicate that TNFα released by tumor cell-activated macrophages is critical for increased MCP-1 production by tumors cells. Thus, disruption of tumor-stromal cell interaction may inhibit tumor progression by reducing the production of tumor-promoting proinflammatory mediators, such as MCP-1.

  5. Crosstalk between Tumor Cells and Macrophages in Stroma Renders Tumor Cells as the Primary Source of MCP-1/CCL2 in Lewis Lung Carcinoma

    Directory of Open Access Journals (Sweden)

    Teizo eYoshimura

    2015-06-01

    Full Text Available The chemokine MCP-1/CCL2 is produced by a variety of tumors and plays an important role in cancer progression. We and others previously demonstrated that the primary source of MCP-1 in several mouse tumors, including 4T1 breast cancer, M5076 sarcoma and B16 melanoma, was stromal cells. In the present study, we identified that tumor cells were the primary source of MCP-1 in Lewis lung carcinoma (LLC, because MCP-1 mRNA was highly expressed in tumors grown in both WT and MCP-1-/- mice with elevated serum MCP-1 levels. Since LLC cells isolated from tumors expressed low levels of MCP-1 in vitro, it appeared that the tumor-stromal cell interaction in a tumor microenvironment increased MCP-1 expression in LLC cells. In fact, co-culture of LLC cells with normal mouse peritoneal macrophages or normal lung cells containing macrophages increased MCP-1 expression by LLC cells. Macrophages from TNFα-/- mice failed to activate LLC cells and anti-TNFα neutralizing antibody abolished the effect of WT macrophages on LLC cells. When LLC cells were transplanted into TNFα-/- mice, the levels of MCP-1 mRNA in tumors and serum MCP-1 levels were markedly lower as compared to WT mice, and importantly tumors grew more slowly. Taken together, our results indicate that TNFα released by tumor cell-activated macrophages is critical for increased MCP-1 production by tumors cells. Thus, disruption of tumor-stromal cell interaction may inhibit tumor progression by reducing the production of tumor-promoting proinflammatory mediators, such as MCP-1.

  6. MCP2515在TTCAN协议Level 1节点中应用

    Institute of Scientific and Technical Information of China (English)

    孟庆栋; 张凤登; 刘荣鹏

    2007-01-01

    TCAN是基于CAN的时间触发的高层协议,具有确定性行为,因而适用于安全相关的场合。本文首先从参照时间、基本周期、系统信息阵、网络时间单元和全局时间五个方面对TTCAN协议进行分析,其后讲解了基于MCP2515的一个TTCAN协议Level 1节点的实现方案。

  7. Physical, chemical and sensory changes of refrigerated yellow pitahaya treated preharvest with 1-mcp

    OpenAIRE

    Liliana Serna Cock; Laura Sofía Torres Valenzuela; Alfredo Ayala Aponte

    2013-01-01

    El efecto de la aplicación de soluciones acuosas de 0, 200 y 400 mg L de 1-metilciclopropeno (1-MCP) en pitahaya amarilla en precosecha (Selenicereus megalanthus Haw) fue evaluado. Se midieron los cambios en pérdida de peso, cambio total de la coloración, azucares totales, acidez titulable, ácido ascórbico y análisis sensorial. La pitahaya fue almacenada bajo refrigeración (10°C y 85% de humedad relativa por 29 días). Dos tipos de empaque (Cajas para exportación y canastillas plá...

  8. Phenolic excipients of insulin formulations induce cell death, pro-inflammatory signaling and MCP-1 release

    Directory of Open Access Journals (Sweden)

    Claudia Weber

    2015-01-01

    Insulin solutions displayed cytotoxic and pro-inflammatory potential caused by phenol or m-cresol. We speculate that during insulin pump therapy phenol and m-cresol might induce cell death and inflammatory reactions at the infusion site in vivo. Inflammation is perpetuated by release of MCP-1 by activated monocytic cells leading to enhanced recruitment of inflammatory cells. To minimize acute skin complications caused by phenol/m-cresol accumulation, a frequent change of infusion sets and rotation of the infusion site is recommended.

  9. Invited article: a test-facility for large-area microchannel plate detector assemblies using a pulsed sub-picosecond laser.

    Science.gov (United States)

    Adams, Bernhard; Chollet, Matthieu; Elagin, Andrey; Oberla, Eric; Vostrikov, Alexander; Wetstein, Matthew; Obaid, Razib; Webster, Preston

    2013-06-01

    The Large Area Picosecond Photodetector Collaboration is developing large-area fast photodetectors with time resolution tests on bare 8 in.-square MCP plates or into a smaller chamber for tests on 33-mm circular substrates. We present the experimental setup, detector calibration, data acquisition, analysis tools, and typical results demonstrating the performance of the test facility.

  10. Myocardial production and release of MCP-1 and SDF-1 following myocardial infarction: differences between mice and man

    Directory of Open Access Journals (Sweden)

    Palasubramaniam Dharshan

    2011-09-01

    Full Text Available Abstract Background Stem cell homing to the heart is mediated by the release of chemo-attractant cytokines. Stromal derived factor -1 alpha (SDF-1a and monocyte chemotactic factor 1(MCP-1 are detectable in peripheral blood after myocardial infarction (MI. It remains unknown if they are produced by, and released from, the heart in order to attract stem cells to repair the damaged myocardium. Methods Murine hearts were studied for expression of MCP-1 and SDF-1a at day 3 and day 28 following myocardial infarction to determine whether production is increased following MI. In addition, we studied the coronary artery and coronary sinus (venous blood from patients with normal coronary arteries, stable coronary artery disease (CAD, unstable angina and MI to determine whether these cytokines are released from the heart into the systemic circulation following MI. Results Both MCP-1 and SDF-1a are constitutively produced and released by the heart. MCP-1 mRNA is upregulated following murine experimental MI, but SDF-1a is suppressed. There is less release of SDF-1a into the systemic circulation in patients with all stages of CAD including MI, mimicking the animal model. However MCP-1 release from the human heart following MI is also suppressed, which is the exact opposite of the animal model. Conclusions SDF-1a and MCP-1 release from the human heart are suppressed following MI. In the case of SDF-1a, the animal model appropriately reflects the human situation. However, for MCP-1 the animal model is the exact opposite of the human condition. Human observational studies like this one are paramount in guiding translation from experimental studies to clinical trials.

  11. Characterization of endocannabinoid-mediated induction of myeloid-derived suppressor cells involving mast cells and MCP-1.

    Science.gov (United States)

    Jackson, Austin R; Hegde, Venkatesh L; Nagarkatti, Prakash S; Nagarkatti, Mitzi

    2014-04-01

    Endocannabinoids are lipid-signaling molecules found in the nervous system; however, their precise role in the periphery is unclear. In the current study, we observed that a single i.p. administration of AEA caused rapid induction of MDSCs. The MDSCs contained a mixture of granulocytic and monocytic subtypes and expressed Arg-1 and iNOS. The MDSCs suppressed T cell proliferation in vitro and used iNOS to mediate their effect. Moreover, adoptive transfer of MDSCs led to suppression of mBSA-induced DTH. Through the use of pharmacological inhibition, as well as genetic knockout mice, we found that the induction of MDSCs by AEA was CB1-dependent. The induction of MDSCs by AEA was reduced significantly in mast cell-deficient mice, while maintained in LPS-insensitive mice, showing that the induction of MDSCs by AEA was dependent, at least in part, on mast cells and independent of TLR4. Chemokine analysis of AEA- treated WT mice showed an early spike of MCP-1, which was decreased in Kit(W/W-sh) mice, showing a role of mast cells in the secretion of MCP-1 in response to AEA. Also, use of antibodies against MCP-1 or mice deficient in MCP-1 confirmed the role played by MCP-1. Interestingly, MCP-1 played a significant role in the induction of monocytic but not granulocytic MDSCs. Our studies demonstrate for the first time that endocannaboinids activate CB1 on mast cells to induce MCP-1, which facilitates recruitment of monocytic MDSCs.

  12. Monocyte chemotactic protein-1 (MCP-1 in patients with chronic schistosomiasis mansoni: evidences of subclinical renal inflammation.

    Directory of Open Access Journals (Sweden)

    Ana Lúcia P Hanemann

    Full Text Available The aim of this study is to investigate renal markers and the biomarker MCP-1 in patients with schistosomiasis mansoni. This is a cross-sectional study with 85 patients aged 5 to 48 years, with a confirmed diagnosis of schistosomiasis mansoni through the Kato-Katz method. The patients were divided in three groups: control (G-I; infected by S. mansoni before treatment (G-II and infected by S. mansoni after treatment (G-III. Renal function was evaluated by tubular and glomerular biomarkers and through urinary MCP-1. Patients' mean age was 23.2 ± 13 years. There was no statistically significant difference between the groups regarding tubular and glomerular function evaluated through the traditional biomarkers. MCP-1 was higher in G-II and G-III, when compared to G-I; p=0.009 and p=0.007, respectively. There was no difference when comparing groups G-II and G-III (p=0.892. Although it was not different among the groups, there was a significant correlation between albuminuria and MCP-1. There was a significant increase in urinary MCP-1 levels in patients with schistosomiasis mansoni, which was associated with albuminuria. This protein has a role in the recruitment of monocytes to injury and inflammation sites . The increase of MCP-1 in the urine evidences that there is silent renal inflammation in these patients and the inflammatory status is not interrupted by specific treatment of the offending agent. Our findings suggest that urinary MCP-1 can be a sensitive marker of renal injury in patients with schistosomiasis mansoni.

  13. Atraso do amadurecimento de banana 'Maçã' pelo 1-MCP, aplicado previamente à refrigeração Ripening delay of 'Apple' banana submitted to 1-MCP, prevoiously applied to refrigeration

    Directory of Open Access Journals (Sweden)

    Gustavo Costa Almeida

    2006-08-01

    Full Text Available O objetivo deste trabalho foi avaliar o efeito de diferentes períodos de exposição da banana 'Maçã' a 50 ppb de 1-MCP (0; 3; 6; 9; 12 e 24 horas sobre sua vida pós-colheita e qualidade. Após exposição ao 1-MCP, os frutos verde-maturos foram armazenados por 30 dias em câmaras com temperatura de 13ºC ± 0,5 e umidade relativa de 95%. Em seguida, as bananas foram armazenadas à temperatura de 20ºC ± 1, até amarelecimento completo da casca. A exposição de banana 'Maçã' a 50 ppb de 1-MCP, por 9 horas, retardou em 7 dias o seu amadurecimento, em comparação a frutos não expostos ao 1-MCP, após 30 dias de armazenamento refrigerado (13ºC, sem prejuízos à sua aparência e composição química. A exposição de banana 'Maçã' a 50 ppb de 1-MCP, por 3 e 6 horas, não estendeu sua vida pós-colheita, tampouco alterou sua composição química. Embora a exposição de banana 'Maçã' a 50 ppb de 1-MCP, por 12 e 24 horas, tenha retardado o seu amadurecimento, promoveu alterações indesejáveis na casca do fruto. Logo, a aplicação de 50 ppb de 1-MCP, por 9 horas, antes da refrigeração, constitui-se numa alternativa viável para prolongar o período de comercialização da banana.The aim of this work was to evaluate 'Apple' banana different periods exposure effect to 50 ppb of 1-MCP (0, 3, 6, 9 and 24 hours on its postharvest life and quality. Mature-green fruits were stored for 30 days in chambers at 13ºC + 0,5 and relative humidity 95%, after exposure to 1-MCP. Then, the bananas were stored at 20ºC + 1 until peel complete yellowing. 'Apple' banana to 50 ppb of 1-MCP exposure during 9 hours delayed in seven days the fruit ripening, comparing to fruit control, after 30 days of cool storage (13ºC, without changing its appearance and chemical composition. The exposure of 'Apple' banana to 50 ppb of 1-MCP for 3 and 6 hours did not extend its postharvest life; neither changed its chemical composition. Although the exposure of

  14. Technology of ultrasonic-electroless plating Ni-P-SiC nanocomposite coating%超声波-化学镀Ni-P-SiC纳米复合镀层的工艺研究

    Institute of Scientific and Technical Information of China (English)

    马春阳; 吴蒙华; 曲智家

    2011-01-01

    Ni-P-SiC nanocomposite coatings were prepared by ultrasonic-electroless plating on surface of 45 steel substrate. Through orthogonal experiment, the technology parameters of plating Ni-P-SiC nanocomposite coatings were optimized and the hest addition amount of SiC nanoparticles. ultrasonic power, temperature of plating liquid and pH value were determined. The microstructure of the coatings was observed and analysed by scanning electron microscopy ( SEM) and atomic force microscopy ( AFM) .%采用超声波-化学镀的方法,在45钢基体表面制备Ni-P-SiC纳米复合镀层.利用正交试验法对制备Ni-P-SiC纳米复合镀层的工艺参数进行优化,并确定SiC纳米粒子的加入量、超声波功率、复合镀液的温度以及pH值.最后,利用扫描电镜(SEM)和原子力显微镜(AFM)对复合镀层的显微组织形貌进行观察和分析.

  15. Near UV imager with an MCP-based photon counting detector

    Science.gov (United States)

    Ambily, S.; Mathew, Joice; Sarpotdar, Mayuresh; Sreejith, A. G.; Nirmal, K.; Prakash, Ajin; Safonova, Margarita; Murthy, Jayant

    2016-07-01

    We are developing a compact UV Imager using light weight components, that can be own on a small CubeSat or a balloon platform. The system has a lens-based optics that can provide an aberration-free image over a wide field of view. The backend instrument is a photon counting detector with off-the-shelf MCP, CMOS sensor and electronics. We are using a Z-stack MCP with a compact high voltage power supply and a phosphor screen anode, which is read out by a CMOS sensor and the associated electronics. The instrument can be used to observe solar system objects and detect bright transients from the upper atmosphere with the help of CubeSats or high altitude balloons. We have designed the imager to be capable of working in direct frame transfer mode as well in the photon-counting mode for single photon event detection. The identification and centroiding of each photon event are done using an FPGA-based data acquisition and real-time processing system.

  16. Targeting tumor-associated macrophages and inhibition of MCP-1 reduce angiogenesis and tumor growth in a human melanoma xenograft.

    Science.gov (United States)

    Gazzaniga, Silvina; Bravo, Alicia I; Guglielmotti, Angelo; van Rooijen, Nico; Maschi, Fabricio; Vecchi, Annunciata; Mantovani, Alberto; Mordoh, José; Wainstok, Rosa

    2007-08-01

    Chemokines such as monocyte chemoattractant protein (MCP)-1 are key agonists that attract macrophages to tumors. In melanoma, it has been previously shown that variable levels of MCP-1/CCL2 appear to correlate with infiltrating macrophages and tumor fate, with low to intermediate levels of the chemokine contributing to melanoma development. To work under such conditions, a poorly tumorigenic human melanoma cell line was transfected with an expression vector encoding MCP-1. We found that M2 macrophages are associated to MCP-1+ tumors, triggering a profuse vascular network. To target the protumoral macrophages recruitment and reverting tumor growth promotion, clodronate-laden liposomes (Clod-Lip) or bindarit were administered to melanoma-bearing mice. Macrophage depletion after Clod-Lip treatment induced development of smaller tumors than in untreated mice. Immunohistochemical analysis with an anti-CD31 antibody revealed scarce vascular structures mainly characterized by narrow vascular lights. Pharmacological inhibition of MCP-1 with bindarit also reduced tumor growth and macrophage recruitment, rendering necrotic tumor masses. We suggest that bindarit or Clod-Lip abrogates protumoral-associated macrophages in human melanoma xenografts and could be considered as complementary approaches to antiangiogenic therapy.

  17. Pós colheita de bananas-maçã submetidas ao 1-MCP e armazenadas á temperatura ambiente Postharvest of 'apple' banana submetted to 1-MCP and storage in room temperature

    Directory of Open Access Journals (Sweden)

    Ana Carla Marque Pinheiro

    2006-04-01

    Full Text Available Bananas da cultivar Maçã foram adquiridas no estádio dois de coloração da casca (verde maturos e submetidas à ação de 1-MCP. O 1-MCP foi aplicado por 12 horas nas seguintes concentrações: 0 (controle, 50, 100, 150, 200 hL.L-1. Após aplicação, os frutos foram armazenados à temperatura ambiente (temperatura média 20ºC ± 1 e umidade relativa 80% ± 5 e avaliados à medida que atingiam os graus 3, 5 e 7 de coloração da casca. O tratamento com 1-MCP atrasou o início do amadurecimento de bananas-maçã armazenadas sob temperatura ambiente, baseado nas primeiras mudanças de coloração da casca. A aplicação de 1-MCP em bananas-maçã, ditou maiores valores de perda de massa e relação polpa/casca (nos graus 5 e 7 de coloração da casca. O 1-MCP, nas doses 100, 150 e 200 hL.L-1 de 1-MCP promoveu desverdecimento desuniforme e tonalidade avermelhada na casca. O tratamento 50 hL.L-1 de 1-MCP é o mais adequado, por promover a extensão da vida pós-colheita de bananas-maçã da cultivar armazenadas sob temperatura ambiente sem afetar a coloração da casca dos frutos, apresentando qualidade, baseando-se na cor da casca, firmeza, acidez titulável, pH e sólidos solúveis, semelhante ao controle.Mature green 'Apple' bananas were submitted to five concentrations of 1-MCP (0, 50, 100, 150 and 200 hL.L-1 for 12 hours. After treatment, the fruits were stored at room temperature (20ºC ± 1 and 80% ± 5 RH and analyzed at 3,5 and 7 color degree of peel. The treatment with 1-MCP delayed the start of the ripening based in the first changes of peel color. The treatment of 'Apple' bananas with 1-MCP promoted higher values of mass loss and pulp/peel ratio (5 and 7 degrees of color peel. The fruits treated with 100, 150 and 200 nL.L-1 of 1-MCP showed heterogeneous degreening and development of red color on the peel. 1-MCP at 50 nL.L-1 was the most appropriated treatment for promoting the extension of postharvest life of 'Apple' bananas stored

  18. Aplicação de 1-MCP em caqui 'quioto' armazenado sob refrigeração e atmosfera controlada Effect of 1-MCP applied at different times during cold and Ca storage

    Directory of Open Access Journals (Sweden)

    Auri Brackmann

    2003-04-01

    Full Text Available O objetivo deste trabalho foi de avaliar o efeito do 1-MCP aplicado em diferentes épocas durante o armazenamento refrigerado (AR e em atmosfera controlada (AC sobre a qualidade do caqui cv. Quioto. O delineamento experimental utilizado foi o inteiramente casualizado, com quatro repetições de 30 frutos, e os tratamentos foram os seguintes: armazenamento refrigerado (AR; armazenamento refrigerado(AR + 1-MCP (1000ppb no início do armazenamento; armazenamento refrigerado(AR +1-MCP (1000ppb no final do armazenamento; armazenamento em atmosfera controlada (AC com 1kPa de O2 e AC 5kPa de CO2 e AC com 1kPa de O2 e 5kPa de CO2 + 1-MCP no fim do armazenamento, após 2 meses de armazenamento a -0,5ºC mais 5 dias de exposição dos frutos a 10ºC e 3 dias a 20ºC. No armazenamento refrigerado, o 1-MCP, aplicado tanto no início do armazenamento como no final, proporcionou maior firmeza de polpa. Para os parâmetros: sólidos solúveis totais, podridão e escurecimento da película, não houve diferença estatística entre os tratamentos. Conclui-se que a aplicação de 1-MCP, tanto no início como no final do armazenamento mantém elevada a firmeza de polpa.The objective of this work was to evaluate the effect of 1-MCP applied at different period during the cold storage (CS and in controlled atmosphere (CA on the quality of 'Quioto'. Persimmon. The experimental design was completely randomized with four replications of 30 fruits and the tested treatments were: cold storage (CS, cold storage + 1-MCP (1000ppb in the beginning of the storage, cold storage + 1-MCP (1000ppb in the end of the storage period; storage in controlled atmosphere (CA with 1kPa of O2 and 5kPa of CO2 and 1kPa of O2 and 5kPa of CO2 + 1-MCP in the end of the storage, after 2 months of storage at -0.5ºC, plus 5 days at 10ºC and 3 days at 20ºC. In the cooled storage, the 1-MCP, applied as in the beginning of the storage as in the end of the storage, provided greater pulp firmness

  19. Experimental investigation of the radiation shielding of a MCP detector in the radiation environment near Europa

    Science.gov (United States)

    Tulej, Marek; Wurz, Peter; Meyer, Stefan; Lasi, Davide; Lüthi, Matthias; Galli, André; Piazza, Daniele; Desorgher, Laurent; Hajdas, Wojciech; Reggiani, Davide; Karlsson, Stefan; Kalla, Leif

    2016-04-01

    The Neutral Ion Mass spectrometer (NIM) is one of the six instruments in the Particle Environmental Package (PEP) designed for the JUICE mission of ESA to the Jupiter system. NIM will conduct detailed measurements of chemical composition of Jovian moon exospheres and is equipped with a sensitive MCP ion detector. To maintain high sensitivity of the NIM instrument, background signals arising from the presence of a large background of penetrating radiation (mostly high-energy electrons and protons) in Jupiter's magnetosphere have to be minimised. We investigate the performance of a layered-Z radiation shield, an Al-Ta-Al sandwich, as a potential shielding against high-energy electrons. The experimental investigations were performed at the PiM1 beam line of the High Intensity Proton Accelerator Facilities located at the Paul Scherrer Institute (PSI), Villigen, Switzerland. The facility delivers a particle beam containing e,  and  with an adjustable momentum ranging from 17.5 to 345 MeV/c. The measurements of the induced radiation background generated during the interaction of primary particles with Al-Ta-Al sandwich were conducted by beam diagnostic methods and a MCP detector. Diagnostic methods provided for the characterisation of the beam parameters (beam geometry, flux and intensity) and identification of individual particles in the primary beam and in the flux of secondary particles. The MCP detector measurements provided information on the effects of radiation and the results of these measurements define the performance of the shielding material in reducing the background arising from penetrating radiation. In parallel, we performed modelling studies using GEANT 4 and GRASS methods to identify products of the interaction and predict their fluxes and particle rates at the MCP detector. Combination of the experiment and modelling studies yields detailed characterisation of the radiation effects produced by the interaction of the incident e- in the

  20. High Spatial Resolution Investigations of Microchannel Plate Imaging Properties for UV Detectors

    Science.gov (United States)

    Siegmund, Oswald

    1996-01-01

    Microchannel plate (MCP) photon counting detectors are currently being used with great success on many of the recent NASA/ESA ultraviolet (UV) astrophysics missions that make observations in the 1OO A - 1600 A range. These include HUT, the Wide Field Camera on ROSAT, EUVE, ALEXIS, ORFEUS, and SOHO. These devices have also been chosen to fly on future UV astrophysics missions such as FUSE, FUVITA, IMAGE, and both the HST STIS and Advanced Camera instruments. During the period of this award we have fabricated a dual-chamber vacuum test facility to carry out laboratory testing of detector resolution, image stability and linearity, and flat field performance to enable us to characterize the performance of MCPs and their associated read-out architectures. We have also fabricated and tested a laboratory 'test-bed' delay line detector, which can accommodate MCP's with a wide range of formats and run at high data rates, to continue our studies of MCP image fixed pattern noise, and particularly for new small pore MCP's which have recently come onto the market. These tests were mainly focussed on the assessment of cross delay-line (XDL) and double delay line (DDL) anode read-out schemes, with particular attention being focussed on flat-field and spatial resolution performance.

  1. Nano-oxide thin films deposited via atomic layer deposition on microchannel plates.

    Science.gov (United States)

    Yan, Baojun; Liu, Shulin; Heng, Yuekun

    2015-01-01

    Microchannel plate (MCP) as a key part is a kind of electron multiplied device applied in many scientific fields. Oxide thin films such as zinc oxide doped with aluminum oxide (ZnO:Al2O3) as conductive layer and pure aluminum oxide (Al2O3) as secondary electron emission (SEE) layer were prepared in the pores of MCP via atomic layer deposition (ALD) which is a method that can precisely control thin film thickness on a substrate with a high aspect ratio structure. In this paper, nano-oxide thin films ZnO:Al2O3 and Al2O3 were prepared onto varied kinds of substrates by ALD technique, and the morphology, element distribution, structure, and surface chemical states of samples were systematically investigated by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), and X-ray photoemission spectroscopy (XPS), respectively. Finally, electrical properties of an MCP device as a function of nano-oxide thin film thickness were firstly studied, and the electrical measurement results showed that the average gain of MCP was greater than 2,000 at DC 800 V with nano-oxide thin film thickness approximately 122 nm. During electrical measurement, current jitter was observed, and possible reasons were preliminarily proposed to explain the observed experimental phenomenon.

  2. Armazenamento refrigerado de ameixas 'Laetitia' com uso de 1-MCP e indução de perda de massa fresca Cold storage of 'Laetitia' plums treated with 1-MCP and induced to loss of fresh mass

    Directory of Open Access Journals (Sweden)

    Erlani de Oliveira Alves

    2010-02-01

    Full Text Available O objetivo deste trabalho foi avaliar os efeitos da temperatura de armazenamento, do uso de 1-metilciclopropeno (1-MCP e da indução de perda de massa fresca (IPMF na qualidade de ameixas 'Laetitia'. Os tratamentos utilizados foram: -0,5°C; 0,5°C; 0,5°C em combinação com a indução de perda de massa fresca (IPMF; e 0,5°C após tratamento com aplicação de 1-MCP (1,0µL L-1. Frutos armazenados a 0,5°C e tratados com 1-MCP apresentaram os menores valores da taxa respiratória e da taxa de produção de etileno após quatro dias de exposição em condição ambiente (23°C / 60% de UR. Na saída da câmara fria não houve diferença entre tratamentos. Os frutos armazenados por 30 dias a 0,5°C, em combinação com a IPMF ou 1-MCP, apresentaram na saída da câmara maior firmeza de polpa. Porém, após quatro dias, apenas os frutos armazenados a 0,5°C e tratados com 1-MCP apresentaram maior firmeza de polpa. O índice de cor vermelha, na saída da câmara, foi menor nos frutos armazenados a -0,5°C e a 0,5°C após tratamento com 1-MCP, não sendo observada diferença entre os tratamentos após quatro dias de exposição dos frutos em temperatura ambiente. O armazenamento a -0,5°C proporcionou melhor preservação dos atributos de textura dos frutos do que a 0,5°C, e nesta temperatura o tratamento com 1-MCP proporcionou os melhores resultados. O armazenamento a 0,5°C em relação a -0,5°C causou incremento na incidência de degenerescência da polpa após quatro dias de exposição dos frutos em condição ambiente. A melhor temperatura para o armazenamento refrigerado de ameixas 'Laetitia' é de -0,5°C. O uso do 1-MCP e a IPMF contribuem para a manutenção da qualidade dos frutos durante o armazenamento, e o efeito do 1-MCP persiste após o armazenamento.This research was carried out to study the effects of storage temperature, treatment with 1-methycyclopropene (1-MCP, and induction of fresh mass loss (IFML on quality of 'Laetitia

  3. Peritonitis, peritoneal inflammation and membrane permeability: a longitudinal study of dialysate and serum MCP-1 in stable patients on peritoneal dialysis.

    Science.gov (United States)

    Malik, Amir R; Little, Mark A; Henriksson, Marie; Tam, Frederick W K; Brown, Edwina A

    2007-01-01

    Increase in peritoneal membrane permeability (D/P) correlates with systemic and peritoneal markers of inflammation and neoangiogenesis. Monocyte chemoattractant protein-1 (MCP-1, CCL2) is a potent chemoattractant and activator of monocytes/macrophages. We measured the serum (sMCP-1) and dialysate MCP-1 (dMCP-1) concentrations of stable peritoneal dialysis (PD) patients and studied various factors affecting MCP-1 production. We also looked at the correlation of dMCP-1 concentrations with change in D/P over 12 months. Forty-five stable prevalent and 6 new PD patients (22 CAPD, 29 APD) were studied. Median PD duration was 21 months (range 1-114). D/P was measured by standardized peritoneal equilibration test (PET). Patients with recent peritonitis within 3 months of the start of study were excluded. MCP-1 concentrations were measured in serum, overnight dialysate and post-PET dialysate, both at baseline and at 12 months by ELISA. On univariate analysis, post-PET dMCP-1 concentrations positively correlated with sMCP-1 (p=0.0002), duration of PD (p=0.02), dialysate volume (p=0.001), peritoneal creatinine clearance (p=0.0002) and D/P (p=0.001). There was a negative correlation with residual renal function (p=0.001). dMCP-1 concentrations were higher in patients with past peritonitis (p=0.001). On multivariate analysis, factors independently associated with dMCP-1 were sMCP-1 (p=0.003) and past peritonitis (p=0.001). Thirty patients completed this study, and D/P rose by > 0.1 in 20% patients. dMCP-1 concentrations were higher in baseline and 12-month samples in patients with change in D/P >0.1. We conclude that dMCP-1 concentrations are related to past peritonitis and serum MCP-1. It is difficult to interpret the relationship of dMCP-1 with change in D/P over time due to the small number of patients.

  4. Vps13-Mcp1 interact at vacuole-mitochondria interfaces and bypass ER-mitochondria contact sites.

    Science.gov (United States)

    John Peter, Arun T; Herrmann, Beatrice; Antunes, Diana; Rapaport, Doron; Dimmer, Kai Stefan; Kornmann, Benoît

    2017-10-02

    Membrane contact sites between endoplasmic reticulum (ER) and mitochondria, mediated by the ER-mitochondria encounter structure (ERMES) complex, are critical for mitochondrial homeostasis and cell growth. Defects in ERMES can, however, be bypassed by point mutations in the endosomal protein Vps13 or by overexpression of the mitochondrial protein Mcp1. How this bypass operates remains unclear. Here we show that the mitochondrial outer membrane protein Mcp1 functions in the same pathway as Vps13 by recruiting it to mitochondria and promoting its association to vacuole-mitochondria contacts. Our findings support a model in which Mcp1 and Vps13 work as functional effectors of vacuole-mitochondria contact sites, while tethering is mediated by other factors, including Vps39. Tethered and functionally active vacuole-mitochondria interfaces then compensate for the loss of ERMES-mediated ER-mitochondria contact sites. © 2017 John Peter et al.

  5. Factorial Construction Technology of High Speed Railway Reactive Powder Concrete Cover Plate%高速铁路活性粉末混凝土盖板工厂化施工技术

    Institute of Scientific and Technical Information of China (English)

    徐保军

    2016-01-01

    活性粉末混凝土是一种具有高强度、高耐久性及良好韧性的新型水泥基复合材料,具有广阔的研究与应用前景。本文介绍了RPC盖板的生产技术、设计生产控制方式,并对其关键技术进行了初步探讨,提出了RPC盖板生产中需要加强、改进、掌握的新技术、新概念。%Reactive powder concrete is a new kind of cement-based composite material with high strength, high durability and good toughness, which has a broad prospect of research and application. This paper introduced the production technology and design and production control mode of RPC cover plate, studied its key techniques, and presented the new technology and new concepts that are needed to strengthen and improve in the RPC cover plate production.

  6. Connection joint construction technology of super-high-rise silo structure bearing plate and silo structure%超高层框筒结构楼承板与筒体连接节点施工工艺

    Institute of Scientific and Technical Information of China (English)

    程爱珍

    2015-01-01

    The paper introduces the joint connection technology principles of super-high-rise silo bearing plate and silo structure,and describes its construction technology procedures and operation points,and summarizes its construction quality,safety and environment protection measures, which guarantees the joint stress performance of bearing plate and silo connection. Therefore,it has wide application prospect in high-rise build-ing construction.%介绍了超高层框筒结构楼承板与筒体连接节点的衔接工艺原理,阐述了其施工工艺流程及操作要点,总结了施工中的质量、安全、环保措施,指出该技术保证了楼承板与筒体连接节点的受力性能,在高层建筑施工中有广泛的应用前景。

  7. MicroCameras and Photometers (MCP) instrument on board TARANIS satellite: scientific objectives, design, characterization results and products

    Science.gov (United States)

    Farges, T.; Hébert, P.; Le Mer-Dachard, F.; Cansot, E.; Offroy, M.; Ravel, K.; Gaillac, S.; Sato, M.; Blanc, E.

    2015-12-01

    TARANIS (Tool for the Analysis of Radiations from lightNings and Sprites) is a CNES micro satellite. Its main objective is to study impulsive transfers of energy between the Earth atmosphere and the space environment. It will be sun-synchronous at an altitude of 700 km. It will be launched from late 2017 for at least 2 years. Its payload is composed of several electromagnetic instruments in different wavelengths (from gamma-rays to radio waves including optical). TARANIS instruments are currently in calibration and qualification phase. The purpose of this poster is to present the MicroCameras and Photometers (MCP) scientific objectives and the sensor design, to show the performances of this instrument using the recent characterization, and at last to promote its products. The MicroCameras, developed by Sodern, are dedicated to the spatial description of TLEs and their parent lightning. They are able to differentiate sprite and lightning thanks to two narrow bands ([757-767 nm] and [772-782 nm]) that provide simultaneous pairs of images of an Event. The calibration results will be detailed. Simulation results of the differentiation method will be shown. Photometers, developed by Bertin Technologies, will provide temporal measurements and spectral characteristics of TLEs and lightning. It is a key instrument because of its on-board detection of the TLEs which can trigger the whole payload. Photometers use four spectral bands in the [170-260 nm], [332-342 nm], [757-767 nm] and [600-900 nm] and have the same field of view as cameras. The calibration results will also be detailed. The on-board TLE detection algorithm remote-controlled parameters will be tuned before launch using the electronic board and simulated or real events waveforms. Automatic classification tools are now tested to produce for the Scientific Mission Center some lists of elves, sprites or lightning without TLE following the recent work of Offroy et al. [2015] using ISUAL spectrophotometer data.

  8. Insulin resistance is associated with MCP1-mediated macrophage accumulation in skeletal muscle in mice and humans.

    Directory of Open Access Journals (Sweden)

    David Patsouris

    Full Text Available Inflammation is now recognized as a major factor contributing to type 2 diabetes (T2D. However, while the mechanisms and consequences associated with white adipose tissue inflammation are well described, very little is known concerning the situation in skeletal muscle. The aim of this study was to investigate, in vitro and in vivo, how skeletal muscle inflammation develops and how in turn it modulates local and systemic insulin sensitivity in different mice models of T2D and in humans, focusing on the role of the chemokine MCP1. Here, we found that skeletal muscle inflammation and macrophage markers are increased and associated with insulin resistance in mice models and humans. In addition, we demonstrated that intra-muscular TNFα expression is exclusively restricted to the population of intramuscular leukocytes and that the chemokine MCP1 was associated with skeletal muscle inflammatory markers in these models. Furthermore, we demonstrated that exposure of C2C12 myotubes to palmitate elevated the production of the chemokine MCP1 and that the muscle-specific overexpression of MCP1 in transgenic mice induced the local recruitment of macrophages and altered local insulin sensitivity. Overall our study demonstrates that skeletal muscle inflammation is clearly increased in the context of T2D in each one of the models we investigated, which is likely consecutive to the lipotoxic environment generated by peripheral insulin resistance, further increasing MCP1 expression in muscle. Consequently, our results suggest that MCP1-mediated skeletal muscle macrophages recruitment plays a role in the etiology of T2D.

  9. Development of manufacturing technology and fabrication of prototype for main coolant pump

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Koon Seok; Han, C.K.; Chei, J.M.; Chung, K.S.; Youn, M.H.; Shin, S.A.; Choi, D.J.; Kim, H.C. [HALLA Industrial Co., Ltd., Pusan (Korea)

    1999-03-01

    This study presents the development of the manufacturing technology for the Main Coolant Pump of the SMART. This report contains the followings; (1) Select axial type pump for the MCP (2) MCP is drived by squirrel-cage induction motor that consisted canned motor type. (3) MCP shaft has three horizontal and one vertical support bearings. (4) Design of several part of the MCP (5) Manufacturing of the performance test motor (6) Design and manufacturing of the speed sensor (7) Procedures for three-axial and five-axial M.C.T., Tig welding and Electron Beam Welding were developed. (8) Conceptional design of the MCP test facility for the performance test under operating conditions. (9) Results of standard weld test specimens according to the ASME section IX. (author). 21 refs., 35 figs., 10 tabs.

  10. 替代镀金的环境友好型工艺%Environment-friendly technology used for replacing gold plating

    Institute of Scientific and Technical Information of China (English)

    贾成林; 张宝根; 段练

    2015-01-01

    The solvent type SP-2085C and water-soluble LP-1087C electrical contact lubrication protective agents used for replacing gold plating on copper and copper alloy substrates were introduced. Their preparation and coating processes were described. Through corrosion resistance tests (damp-heat, sulfur dioxide atmosphere, and salt spray) and electrical property tests (dielectric strength, insulation resistance, contact resistance, microwave transmission, and weldability), it was showed that, compared with the substrates coated with gold and untreated ones, the two materials not only can substitute gold plating, but also provide better corrosion resistance for copper and copper alloy surfaces than gold plating, not affecting the electrical properties and microwave transmission of products. Besides, the two materials are more environmentally friendly with lower prices.%介绍了可代替铜及铜合金基体镀金用的保护材料──溶剂型SP-2085C和水溶性LP-1087C电接触润滑保护剂,说明了其制备方法与涂覆工艺。通过抗腐蚀性试验(湿热、SO2气氛和盐雾)及电气性能试验(抗电强度、绝缘电阻、接触电阻、微波性能和可焊性),并与镀金板以及未做处理的基材对比,证明这2种材料不仅能替代镀金,而且涂覆后的铜表面耐蚀性优于镀金表面,电气性能和微波传输性未受影响,对环境更友好,且成本更低。

  11. Monocytes infiltrate the pancreas via the MCP-1/CCR2 pathway and differentiate into stellate cells.

    Directory of Open Access Journals (Sweden)

    Kazuko Ino

    Full Text Available Recent studies have shown that monocytes possess pluripotent plasticity. We previously reported that monocytes could differentiate into hepatic stellate cells. Although stellate cells are also present in the pancreas, their origin remains unclear. An accumulation of enhanced green fluorescent protein (EGFP(+CD45(- cells was observed in the pancreases and livers of chimeric mice, which were transplanted with a single hematopoietic stem cell isolated from EGFP-transgenic mice and treated with carbon tetrachloride (CCl4. Because the vast majority of EGFP(+CD45(- cells in the pancreas expressed stellate cell-associated antigens such as vimentin, desmin, glial fibrillary acidic protein, procollagen-I, and α-smooth muscle actin, they were characterized as pancreatic stellate cells (PaSCs. EGFP(+ PaSCs were also observed in CCl4-treated mice adoptively transferred with monocytes but not with other cell lineages isolated from EGFP-transgenic mice. The expression of monocyte chemoattractant protein-1 (MCP-1 and angiotensin II (Ang II increased in the pancreas of CCl4-treated mice and their respective receptors, C-C chemokine receptor 2 (CCR2 and Ang II type 1 receptor (AT1R, were expressed on Ly6C(high monocytes isolated from EGFP-transgenic mice. We examined the effect of an AT1R antagonist, irbesartan, which is also a CCR2 antagonist, on the migration of monocytes into the pancreas. Monocytes migrated toward MCP-1 but not Ang II in vitro. Irbesartan inhibited not only their in vitro chemotaxis but also in vivo migration of adoptively transferred monocytes from peripheral blood into the pancreas. Irbesartan treatment significantly reduced the numbers of EGFP(+F4/80(+CCR2(+ monocytic cells and EGFP(+ PaSCs in the pancreas of CCl4-treated chimeric mice receiving EGFP(+ bone marrow cells. A specific CCR2 antagonist RS504393 inhibited the occurrence of EGFP(+ PaSCs in injured mice. We propose that CCR2(+ monocytes migrate into the pancreas possibly via the

  12. Evaluation of BICRON NE MCP DXT-RAD passive extremity dosemeter

    CERN Document Server

    Yuen, P S; Frketich, G; Rotunda, J

    1999-01-01

    Passive extremity dosemeters currently used in dosimetry communities worldwide have shortcomings. In general, an extremity dosemeter has too thick a detector element, and the dosemeter response is highly energy dependent for beta rays with energies ranging from 200 keV to 2 MeV. It often does not have dosemeter identification, causing problems in the chain of custody. It is often read manually, rendering reading/packing operations very labour intensive. As a result of collaboration between AECL and BICRON NE, a new extremity dosemeter, incorporating a highly sensitive LiF:Mg,Cu,P TLD and tentatively code named MCP DXT-RAD, was developed. It has been evaluated for radiological performance against an ISO draft standard for extremity dosemeters in twelve categories: homogeneity, detection threshold, beta ray energy response, beta angular response, photon energy response, photon angular response, reproducibility, stability under various climatic conditions, linearity, residue, self irradiation, and effect of ligh...

  13. High Resolution Photon Timing with MCP-PMTs: A Comparison of a Commercial Constant Fraction Discriminator (CFD) with the ASIC-based Waveform Digitizers TARGET and WaveCatcher

    Energy Technology Data Exchange (ETDEWEB)

    Breton, D.; /Orsay, LAL; Delagnes, E.; /DAPNIA, Saclay; Maalmi, J.; /Orsay, LAL; Nishimura, K.; Ruckman, L.L.; Varner, G.; /Hawaii U.; Va' vra, J.; /SLAC

    2011-07-14

    There is a considerable interest to develop new time-of-flight detectors using, for example, micro-channel-plate photodetectors (MCP-PMTs). The question we pose in this paper is if new waveform digitizer ASICs, such as the WaveCatcher and TARGET, operating with a sampling rate of 2-3 GSa/s can compete with 1GHz BW CFD/TDC/ADC electronics. We have performed a series of measurements with these waveform digitizers coupled to MCP-PMTs operating at low gain and with a signal equivalent to {approx}40 photoelectrons. The tests were done with a laser diode on detectors operating under the same condition used previously in SLAC and Fermilab beam tests. Our test results indicate that one can achieve similar resolution with both methods. Although the commercial CFD-based electronics does exist and performs very well, it is difficult to implement on a very large scale, and therefore the custom electronics is needed. In addition, the analog delay line requirement makes it very difficult to incorporate CFD discriminators in ASIC designs.

  14. Position sensitive anodes for MCP read-out using induced charge measurement

    Science.gov (United States)

    Jagutzki, O.; Lapington, J. S.; Worth, L. B. C.; Spillman, U.; Mergel, V.; Schmidt-Böcking, H.

    2002-01-01

    We investigate the method of an indirect detection of a MCP charge avalanche projected onto a resistive layer (G. Battistoni, et al., Nucl. Instr. and Meth., 202 (1982) 459). If the sheet resistance is favourable one can detect the charge cloud by the capacitive coupling to an anode structure a few millimetres behind the layer. The anode structure can be, for example, a wedge-and-strip electrode pattern (M. Unverzagt, Diplomarbeit, Universität Frankfurt 1992, private communication) as it is used for directly collecting the electron avalanche from a MCP. Detection of the induced charge is beneficial in several respects. Firstly, image distortions produced by secondary electron mediated charge redistribution are eliminated. Secondly, the noise component due to quantized charge collection, commonly referred to as partition noise, is not present. In addition, the dielectric substrate can function both as an element of the vacuum enclosure and HV insulator, making the electrical connections easily accessible and the pattern operable at ground potential, independently of detector operating voltages. This technique can be used to simplify the electronic design requirements where varying high voltages are required at the detector input face such as plasma analysers, etc. It also has application in the manufacture of intensifier tubes (J. Barnstedt, M. Grewing, Nucl. Instr. and Meth., these proceedings) where the inclusion of a readout pattern inside the intensifier body with associated electrical feed-throughs can prove problematic. We will present data on the performance of such detection geometries using several types of charge division anode, and discuss the advantages compared with the "traditional" charge collecting method.

  15. 平板X射线成像技术在螺旋埋弧焊管检测中的应用%Application of X-ray Plate Panel Imaging Technology in the Detection of SAWH Pipe

    Institute of Scientific and Technical Information of China (English)

    吴金辉; 梁根选; 王树人; 王建华

    2011-01-01

    This paper introduced the working theory of X-ray plate panel imaging technology and its application in the flaw detection of SAWH pipe. Some advantages of this technology were summarized, such as high sensitivity,long service life, uninterrupted by magnetic field, small space occupation and small doses of radiation. The application prospect of X-ray plate panel imaging technology in quantitatively detecting flaw size was also analyzed, and pointed out that it should meet the requirement of forming 25 ~ 30 pictures per second during weld dynamic imaging, this requires high enough time resolution and little enough hysteretic nature, otherwise "tailing" phenomena will appear.%介绍了平板X射线成像技术的工作原理及其在螺旋埋弧焊管检测中的应用,总结出其具有检测灵敏度高、使用寿命长、不受磁场干扰、占用场地小、辐射剂量小等优点,分析了平板X射线成像技术在缺陷尺寸定量分析方面的应用前景,指出该技术用在焊缝动态成像检测时,需要满足每秒生成25~30帧图像的要求,这就要求要有足够高的时间分辨率及足够小的滞后特性,否则将出现"拖尾"现象.

  16. Monte Carlo simulations of microchannel plate detectors I: steady-state voltage bias results

    Energy Technology Data Exchange (ETDEWEB)

    Ming Wu, Craig Kruschwitz, Dane Morgan, Jiaming Morgan

    2008-07-01

    X-ray detectors based on straight-channel microchannel plates (MCPs) are a powerful diagnostic tool for two-dimensional, time-resolved imaging and timeresolved x-ray spectroscopy in the fields of laser-driven inertial confinement fusion and fast z-pinch experiments. Understanding the behavior of microchannel plates as used in such detectors is critical to understanding the data obtained. The subject of this paper is a Monte Carlo computer code we have developed to simulate the electron cascade in a microchannel plate under a static applied voltage. Also included in the simulation is elastic reflection of low-energy electrons from the channel wall, which is important at lower voltages. When model results were compared to measured microchannel plate sensitivities, good agreement was found. Spatial resolution simulations of MCP-based detectors were also presented and found to agree with experimental measurements.

  17. A novel ZVS high voltage power supply for micro-channel plate photomultiplier tubes

    Science.gov (United States)

    Pei, Chengquan; Tian, Jinshou; Liu, Zhen; Qin, Hong; Wu, Shengli

    2017-04-01

    A novel resonant high voltage power supply (HVPS) with zero voltage switching (ZVS), to reduce the voltage stress on switching devices and improve conversion efficiency, is proposed. The proposed HVPS includes a drive circuit, a transformer, several voltage multiplying circuits, and a regulator circuit. The HVPS contains several secondary windings that can be precisely regulated. The proposed HVPS performed better than the traditional resistor voltage divider, which requires replacing matching resistors resulting in resistor dispersibility in the Micro-Channel Plate (MCP). The equivalent circuit of the proposed HVPS was established and the operational principle analyzed. The entire switching element can achieve ZVS, which was validated by a simulation and experiments. The properties of this HVPS were tested including minimum power loss (240 mW), maximum power loss (1 W) and conversion efficiency (85%). The results of this research are that the proposed HVPS was suitable for driving the micro-channel plate photomultiplier tube (MCP-PMT). It was therefore adopted to test the MCP-PMT, which will be used in Daya Bay reactor neutrino experiment II in China.

  18. 微创经皮钢板固定技术结合锁定钢板治疗胫骨粉碎性骨折%MIPPO Technology Combined with Locking Plate in the Treatment of Comminuted Fracture of Tibia

    Institute of Scientific and Technical Information of China (English)

    邵安泽; 岳洋; 潘长军; 顾飞; 吴瑞; 聂玮

    2015-01-01

    目的:观察微创经皮钢板固定(MIPPO)技术闭合复位结合锁定钢板治疗胫骨粉碎性骨折的临床效果.方法:采用MIPPO技术闭合复位结合锁定钢板治疗胫骨粉碎性骨折24例,男17例女7例,年龄23~65岁,平均42.4岁,胫骨中上段骨折15例,胫骨中下段9例.结果:24例患者均获得随访,时间6~14m,平均9.6m,术后采用Johner-Wruhs关节功能评定标准,24例患者优21例,良2例,中1例.结论:运用MIPPO技术闭合复位结合锁定钢板治疗胫骨粉碎性骨折能有效的降低软组织创伤,减少血运破坏,骨折愈合时间短等优点,是治疗胫骨粉碎性骨折的一种有效办法.%Objective: To investigate the use of closed reduction MIPPO technology combined with locking plate in the treatment of tibial comminuted fracture of the clinical effect. Methods:The use of closed reduction MIPPO technology combined locking plate in the treatment of comminuted fracture of the tibia in 24 cases, including 17 males and 7 females, aged 23~65 years, mean 42.4 years, the upper tibia 15 cases of fracture of tibia in nine cases the next segment.Results:24 patients were followed up for 6~14m, average 9.6m, after using Johner-Wruhs joint function evaluation standard, the results were excellent in 21 cases, good in 2 cases, 1 case.Conclusion:Closed reduction MIPPO technology combined with the locking plate in the treatment of comminuted fracture of the tibia with a soft tissue trauma, less blood supply destruction, reliable fixation, fracture healing time is short, etc., it is an effective way to treat comminuted fracture of the tibia.

  19. MCP-1 Stimulates MMP-9 Expression via ERK 1/2 and p38 MAPK Signaling Pathways in Human Aortic Smooth Muscle Cells

    Directory of Open Access Journals (Sweden)

    Ci-Qiu Yang

    2014-07-01

    Full Text Available Objective: We investigated the molecular mechanism underlying the role of monocyte chemoattractant protein-1 (MCP-1 in the formation and development of human abdominal aortic aneurysm (AAA. Methods: We examined protein expression profiles using a protein array and found that MCP-1 was the most highly expressed protein in AAA tissues compared with normal aortas. To investigate the potential mechanism of MCP-1 involvement in the pathogenesis of AAA, we treated human aortic smooth muscle cells (HASMCs with human recombinant MCP-1. Results: MCP-1 was the most highly expressed protein in AAA tissues compared with normal aorta; matrix metalloproteinase-9 (MMP-9 expression was also significantly increased. Treatment with MCP-1 significantly increased the expression and activation of MMP-9 and activated the three major mitogen activated protein kinases (MAPKs extracellular signal regulated kinase (ERK, c-Jun amino terminal kinase (JNK1/2 and p38 MAPK. Furthermore, MCP-1-induced secretion of MMP-9 was inhibited by U0126 (inhibitor of the ERK 1/2 pathway and SB203580 (inhibitor of the p38 MAPK pathway, but not SP600125 (inhibitor of the JNK1/2 pathway. Conclusion: These data demonstrate that MCP-1 stimulates secretion of MMP-9 directly through the ERK1/2 and p38 MAPK mediated pathways in HASMCs. Thus, inhibition of this molecular mechanism might be a potential therapeutic target in the non-surgical treatment of AAA.

  20. 1.5-NM PROJECTION STRUCTURE OF HELA-CELL PROSOME-MCP (PROTEASOME) PROVIDED BY 2-DIMENSIONAL CRYSTALS

    NARCIS (Netherlands)

    PERKINS, GA; BERGSMASCHUTTER, W; KEEGSTRA, W; ARNBERG, AC; COUX, O; SCHERRER, K

    1994-01-01

    We grew two-dimensional crystals of HeLa cell prosomes, also called multicatalytic proteinases (MCP) and proteasomes, for a structure determination by electron microscopy. The molecules were arranged in side views in these crystals. The crystals have p21 plane group symmetry with one particle per

  1. Effects of 1-MCP onthe post-harvest quality of the orange cv. Pera stored under refrigeration

    Directory of Open Access Journals (Sweden)

    Cassia Inês Lourenzi Franco Rosa

    2016-12-01

    Full Text Available ABSTRACT The aim of this work was to analyse the effects of 1-MCP upon the post-harvest quality of the orange cv. Pera stored for 45 days at a temperature of 7 ºC. The fruit was divided into four treatments, and then submitted to the application of three concentrations of 1-methylciclopropene (0.1, 0.5 and 1.0µL.L-1 for a period of 12 hours.The fruitwas again then stored at a temperature of 7 ºC. The rate of respiration was determined, together withcoloration of the epidermis, SS, TA, ratio, vitamin C, total carotenoids, phenolic compounds, total and reducing sugars, weight loss and juice yield. The data were submitted to analysis of variance (F-Test, and the averages were analysed by regression (P≤0.05. According to the results, it could be seen that higher doses of 1-MCP may have caused chemical stress to the orangesunder evaluation, being responsible for the increasein the rate of respiration.Achange in coloration of the epidermis from green to yellow/orange was delayed by the application of 1-MCP; the application of 1-MCP did not cause any alteration to such chemical characteristics as SS, TA, ratio, carotenoids, phenolic compounds or sugars.

  2. Association between new onset diabetic retinopathy and monocyte chemoattractant protein-1 (MCP-1) polymorphism in Japanese type 2 diabetes.

    Science.gov (United States)

    Ninomiya, Hiroyo; Katakami, Naoto; Osonoi, Takeshi; Saitou, Miyoko; Yamamoto, Yuichi; Takahara, Mitsuyoshi; Kawamori, Dan; Matsuoka, Taka-aki; Yamasaki, Yoshimitsu; Shimomura, Iichiro

    2015-06-01

    We longitudinally evaluated the association between monocyte chemoattractant protein-1 (MCP-1) A-2518G polymorphism and new onset of diabetic retinopathy in 758 type 2 diabetic patients. The new onset of retinopathy increased with the increase of the number of G alleles, even after adjustment for age, HbA1c levels, and duration of diabetes.

  3. 1.5-NM PROJECTION STRUCTURE OF HELA-CELL PROSOME-MCP (PROTEASOME) PROVIDED BY 2-DIMENSIONAL CRYSTALS

    NARCIS (Netherlands)

    PERKINS, GA; BERGSMASCHUTTER, W; KEEGSTRA, W; ARNBERG, AC; COUX, O; SCHERRER, K

    1994-01-01

    We grew two-dimensional crystals of HeLa cell prosomes, also called multicatalytic proteinases (MCP) and proteasomes, for a structure determination by electron microscopy. The molecules were arranged in side views in these crystals. The crystals have p21 plane group symmetry with one particle per un

  4. Effectiveness of 1-Methylcyclopropene (1-MCP Combination with Nisin-EDTA Treatment of Fresh-cut Kiwifruit for Prevention

    Directory of Open Access Journals (Sweden)

    Xiang Li

    2014-02-01

    Full Text Available A comprehensive study was made to determine the effects of 1-MCP (1 &muL L-1 pretreated combined with Nisin-EDTA (0.02 M on fresh-cut kiwifruit slices. Physico-chemical attributes of kiwifruit slices were evaluated every 3 days during storage. The fresh-cut kiwifruits pre-treated with 1-MCP, Nisin-EDTA coating and their combination showed better preservation quality and compared with the control slices during the entire storage period. 1-MCP showed an ability to relieve the pulp softening extent and inhibit total chlorophyll content decrease. Lower Polyphenol Oxidase (PPO and higher ascorbic acid were observed in Nisin-EDTA treated samples which also showed a less total bacteria count compared with the control in the end storage. Moreover, the combination of 1-MCP and Nisin-EDTA was more effective than individual treatment on maintaining the quality of fresh-cut kiwifruit, which suggested that this may be a healthy alternative method for fresh-cut kiwifruit.

  5. An Automatic Number Plate Recognition System under Image Processing

    OpenAIRE

    Sarbjit Kaur

    2016-01-01

    Automatic Number Plate Recognition system is an application of computer vision and image processing technology that takes photograph of vehicles as input image and by extracting their number plate from whole vehicle image , it display the number plate information into text. Mainly the ANPR system consists of 4 phases: - Acquisition of Vehicle Image and Pre-Processing, Extraction of Number Plate Area, Character Segmentation and Character Recognition. The overall accuracy and efficiency of whol...

  6. Experimental investigation of the radiation shielding efficiency of a MCP detector in the radiation environment near Jupiter's moon Europa

    Science.gov (United States)

    Tulej, M.; Meyer, S.; Lüthi, M.; Lasi, D.; Galli, A.; Piazza, D.; Desorgher, L.; Reggiani, D.; Hajdas, W.; Karlsson, S.; Kalla, L.; Wurz, P.

    2016-09-01

    Neutral Ion Mass spectrometer (NIM) is one of the instruments in the Particle Environmental Package (PEP) designed for the JUICE mission of ESA to the Jupiter system. NIM, equipped with a sensitive MCP ion detector, will conduct detailed measurements of the chemical composition of Jovian icy moons exospheres. To achieve high sensitivity of the instrument, radiation effects due to the high radiation background (high-energy electrons and protons) around Jupiter have to be minimised. We investigate the performance of an Al-Ta-Al composite stack as a potential shielding against high-energy electrons. Experiments were performed at the PiM1 beam line of the High Intensity Proton Accelerator Facilities located at the Paul Scherrer Institute, Villigen, Switzerland. The facility delivers a particle beam containing e-, μ- and π- with momentum from 17.5 to 345 MeV/c (Hajdas et al., 2014). The measurements of the radiation environment generated during the interaction of primary particles with the Al-Ta-Al material were conducted with dedicated beam diagnostic methods and with the NIM MCP detector. In parallel, modelling studies using GEANT4 and GRAS suites were performed to identify products of the interaction and predict ultimate fluxes and particle rates at the MCP detector. Combination of experiment and modelling studies yields detailed characterisation of the radiation fields produced by the interaction of the incident e- with the shielding material in the range of the beam momentum from 17.5 to 345 MeV/c. We derived the effective MCP detection efficiency to primary and secondary radiation and effective shielding transmission coefficients to incident high-energy electron beam in the range of applied beam momenta. This study shows that the applied shielding attenuates efficiently high-energy electrons. Nevertheless, owing to nearly linear increase of the bremsstrahlung production rate with incident beam energy, above 130 MeV their detection rates measured by the MCP

  7. Gamma-ray detection efficiency of the microchannel plate installed as an ion detector in the low energy particle instrument onboard the GEOTAIL satellite.

    Science.gov (United States)

    Tanaka, Y T; Yoshikawa, I; Yoshioka, K; Terasawa, T; Saito, Y; Mukai, T

    2007-03-01

    A microchannel plate (MCP) assembly has been used as an ion detector in the low energy particle (LEP) instrument onboard the magnetospheric satellite GEOTAIL. Recently the MCP assembly has detected gamma rays emitted from an astronomical object and has been shown to provide unique information of gamma rays if they are intense enough. However, the detection efficiency for gamma rays was not measured before launch, and therefore we could not analyze the LEP data quantitatively. In this article, we report the gamma-ray detection efficiency of the MCP assembly. The measured efficiencies are 1.29%+/-0.71% and 0.21%+/-0.14% for normal incidence 60 and 662 keV gamma rays, respectively. The incident angle dependence is also presented. Our calibration is crucial to study high energy astrophysical phenomena by using the LEP.

  8. Study of the timing performance of micro-channel plate photomultiplier for use as an active layer in a shower maximum detector

    Energy Technology Data Exchange (ETDEWEB)

    Ronzhin, A., E-mail: ronzhin@fnal.gov [Fermilab, Batavia, Il 60510 (United States); Los, S.; Ramberg, E. [Fermilab, Batavia, Il 60510 (United States); Apresyan, A.; Xie, S.; Spiropulu, M. [California Institute of Technology, Pasadena, CA 91126 (United States); Kim, H. [University of Chicago, Chicago, Il 60637 (United States)

    2015-09-21

    We continue the study of micro-channel plate photomultiplier (MCP-PMT) as the active element of a shower maximum (SM) detector. We present test beam results obtained with Photek 240 and Photonis XP85011 MCP-PMTs devices. For proton beams, we obtained a time resolution of 9.6 ps, representing a significant improvement over past results using the same time of flight system. For electron beams, the time resolution obtained for this new type of SM detector is measured to be at the level of 13 ps when we use Photek 240 as the active element of the SM. Using the Photonis XP85011 MCP-PMT as the active element of the SM, we performed time resolution measurements with pixel readout, and achieved a TR better than 30 ps, The pixel readout was observed to improve upon the TR compared to the case where the individual channels were summed.

  9. The prefabricated wall construction technology of PU edge compound board with color plate and rock wool insulation%PU 封边彩钢岩棉复合保温板装配式墙体施工技术

    Institute of Scientific and Technical Information of China (English)

    贾敬峰

    2015-01-01

    介绍了某钢结构厂房外墙采用聚氨酯涂层彩钢岩棉复合板自保温体系施工技术,通过应用墙面板材PU封边技术、对板式墙体节点处理进行了深化设计,并对该施工技术特点、质量标准控制进行了总结,指出该墙体具有保温、隔声性能良好、防水性能优越等优点。%This paper introduced a steel structure building exterior wall on the use of Polyurethane coating compound board with color plate and rock wool insulation system construction,through the application of PU edge on the wall plate,on the panel wall joint processing detailed design, application of the construction technology,summarizes the technical characteristics,quality control standard of the wall,with thermal insulation, sound insulation property,waterproof superior performance advantages.

  10. Study on Intelligent Parking Management System for Stereo Garage Based on License Plate Automatic Recognition Technology%基于车牌自动识别立体车库智能停车管理系统研究

    Institute of Scientific and Technical Information of China (English)

    胡清明; 李西兵; 郭建华; 王世刚; 林颖

    2011-01-01

    An intelligent parking management system based on license plate automatic recognition technology was proposed to resolve the defects of current stereo garage parking management system. The master-slave structure was adopted in the system, namely the host management & control computer and the subordinate license plate automatic recognition system and car saving system. The hardware and software of the system were designed. The test between the host management software and the subordinate MCU was done. It is proved the system is reliable.%针对立体车库现有停车管理系统所存在的缺陷,提出一种基于车牌自动识别技术的智能停车管理系统.系统采用主从式结构,分别为用作管理控制的上位机和车牌识别系统与车辆存取系统的下位机,并完成了系统的软硬件设计.通过对上位机管理软件与下位机单片机显示控制之间的调试,证明了系统的实用性和可靠性.

  11. An adventitial IL-6/MCP1 amplification loop accelerates macrophage-mediated vascular inflammation leading to aortic dissection in mice

    Science.gov (United States)

    Tieu, Brian C.; Lee, Chang; Sun, Hong; LeJeune, Wanda; Recinos, Adrian; Ju, Xiaoxi; Spratt, Heidi; Guo, Dong-Chuan; Milewicz, Dianna; Tilton, Ronald G.; Brasier, Allan R.

    2009-01-01

    Vascular inflammation contributes to cardiovascular diseases such as aortic aneurysm and dissection. However, the precise inflammatory pathways involved have not been clearly defined. We have shown here that subcutaneous infusion of Ang II, a vasopressor known to promote vascular inflammation, into older C57BL/6J mice induced aortic production of the proinflammatory cytokine IL-6 and the monocyte chemoattractant MCP-1. Production of these factors occurred predominantly in the tunica adventitia, along with macrophage recruitment, adventitial expansion, and development of thoracic and suprarenal aortic dissections. In contrast, a reduced incidence of dissections was observed after Ang II infusion into mice lacking either IL-6 or the MCP-1 receptor CCR2. Further analysis revealed that Ang II induced CCR2+CD14hiCD11bhiF4/80– macrophage accumulation selectively in aortic dissections and not in aortas from Il6–/– mice. Adoptive transfer of Ccr2+/+ monocytes into Ccr2–/– mice resulted in selective monocyte uptake into the ascending and suprarenal aorta in regions of enhanced ROS stress, with restoration of IL-6 secretion and increased incidence of dissection. In vitro, coculture of monocytes and aortic adventitial fibroblasts produced MCP-1– and IL-6–enriched conditioned medium that promoted differentiation of monocytes into macrophages, induced CD14 and CD11b upregulation, and induced MCP-1 and MMP-9 expression. These results suggest that leukocyte-fibroblast interactions in the aortic adventitia potentiate IL-6 production, inducing local monocyte recruitment and activation, thereby promoting MCP-1 secretion, vascular inflammation, ECM remodeling, and aortic destabilization. PMID:19920349

  12. Effect of DPA and 1-MCP on chemical compounds related to superficial scald of Granny Smith apples

    Energy Technology Data Exchange (ETDEWEB)

    Moggia, C.; Moya-Leon, M. A.; Pereira, M.; Yuri, J. A.; Lobos, G. A.

    2010-07-01

    Research was carried out to study the mode of action of diphenylamine (DPA) and 1-methylcyclopropene (1-MCP), on control of superficial scald of Granny Smith apples (Malus domestica Borkh.), and its relation with chemical compounds. Fruit was harvested from a commercial orchard in Chile, 182 and 189 days after full bloom and received the following treatments: DPA (2,000 ppm); 1-MCP (1.2 ppm) and control (no treatment). All fruit was stored for 4 or 6 months at 0 degree centigrade. A completely randomized factorial design was used (2 harvest dates by 3 post harvest treatments). Monthly measurements were made on maturity indices, ethylene production rate (EPR), scald related compounds [a-farnesene (AF), conjugated trienes (CT), total anti-oxidants (AO)], and cell membrane stability. Following 4 and 6 months of storage, plus 7 days at 20 degree centigrade, scald was evaluated. After 6 months, DPA-treated fruit, from both harvests, showed similar firmness, EPR and AO, compared to the control. However, AF and CT were lower, and cell membrane stability higher. Conversely, 1-MCP-treated fruit showed a noticeable EPR suppression and AF inhibition, along with higher firmness, lower CT and AO, compared to the control and DPA. Furthermore, cell membrane stability was superior to that of the control and similar to that of the DPA. Treated fruit (DPA and 1-MCP) showed an important reduction in scald compared to the control. The effect of 1-MCP on the investigated compounds and the reduction in scald, confirms that ethylene plays a major role on its development. (Author) 50 refs.

  13. Signal pathways underlying homocysteine-induced production of MCP-1 and IL-8 in cultured human whole blood

    Institute of Scientific and Technical Information of China (English)

    Xiao-kun ZENG; You-fei GUAN; Daniel G REMICK; Xian WANG

    2005-01-01

    Aim: To elucidate the mechanisms underlying homocysteine (Hcy)-induced chemokine production. Methods: Human whole blood was pretreated with inhibitors of calmodulin (CaM), protein kinase C (PKC), protein tyrosine kinase(PTK), mitogen-activated protein kinase (MAPK), and NF-κB and activators of PPARγ for 60 min followed by incubation with Hcy 100 μmol/L for 32 h. The levels of mitogen chemokine protein (MCP)-1 and interleukin-8 (IL-8) were determined by enzyme-linked immunosorbant assay (ELISA). Results: Inhibitors of PKC (calphostin C, 50-500 nmol/L and RO-31-8220, 10-100 nmol/L), CaM(W7, 28-280 μmol/L), ERK1/2 MAPK (PD 98059, 2-20 μmol/L), p38 MAPK(SB 203580, 0.6-6 μmol/L), JNK MAPK (curcumin, 2-10 μmol/L), and NF-κB(PDTC, 10-100 nmol/L) markedly reduced Hcy 100 μmol/L-induced production of MCP-1 and IL-8 in human cultured whole blood, but the inhibitors of PTK(genistein, 2.6-26 μmol/L and tyrphostin, 0.5-5 μmol/L) had no obvious effect on MCP-1 and IL-8 production. PPARγ activators (ciglitazone 30 μmol/L and troglitazone 10 μmol/L) depressed the Hcy-induced MCP-1 production but not IL-8 production in the cultured whole blood. Conclusion: Hcy-induced MCP-1 and IL-8 production is mediated by activated signaling pathways such as PKC,CaM, MAPK, and NF-κB. Our results not only provide clues for the signal transduction pathways mediating Hcy-induced chemokine production, but also offer a plausible explanation for a pathogenic role of hyperhomocysteinemia in these diseases.

  14. MCP-1 -2518 A/G functional polymorphism is associated with increased susceptibility to active pulmonary tuberculosis in Tunisian patients.

    Science.gov (United States)

    Ben-Selma, Walid; Harizi, Hedi; Boukadida, Jalel

    2011-11-01

    Monocyte chemoattractant protein-1 (MCP-1) plays crucial role in protective immunity against Mycobacterium tuberculosis (MT). In this study, we examined whether single nucleotide polymorphism (SNP) -2518 A/G (rs 1024611) of MCP-1 affect the susceptibility to active tuberculosis (TB) in Tunisian populations. Genomic DNA from patients with active TB (168 cases of pulmonary TB and 55 cases of extrapulmonary TB) and ethnically controls (150 cases) was genotyped for the MCP-1 -2518 A/G SNP by polymerase chain reaction fragment length polymorphism (PCR-RFLP). We observed that -2518 G allele and GG genotype (high MCP-1 producer) frequencies were significantly more elevated in active pulmonary TB group in comparison to control group [34 vs. 22%; P = 0.0007; 15 vs. 5%, P corrected for the number of genotypes (Pc) = 0.015; respectively]. Additionally, they were associated with increased risk development of this clinical form of TB [odds ratio (OR) = 1.83, 95% confidence intervals (CI) = 1.26-2.66; OR = 3.1, 95% CI = 1.28-7.76; respectively]. However, wild type allele -2518 A and AA genotype were over-represented in control group (78 and 62%) and seem to be protective factors against TB. Moreover, -2518 AA genotype was more frequent in control group and was associated with resistance against development of active pulmonary TB (OR = 0.56, 95% CI = 0.35-0.89, Pc = 0.03). Our findings confirm the key role of -2518 A/G SNP of MCP-1 and support its association with resistance/susceptibility to the development of active pulmonary TB in the Tunisian population.

  15. Secreted Ectodomain of SIGLEC-9 and MCP-1 Synergistically Improve Acute Liver Failure in Rats by Altering Macrophage Polarity

    Science.gov (United States)

    Ito, Takanori; Ishigami, Masatoshi; Matsushita, Yoshihiro; Hirata, Marina; Matsubara, Kohki; Ishikawa, Tetsuya; Hibi, Hideharu; Ueda, Minoru; Hirooka, Yoshiki; Goto, Hidemi; Yamamoto, Akihito

    2017-01-01

    Effective treatments for acute liver failure (ALF) are still lacking. We recently reported that a single intravenous administration of serum-free conditioned medium from stem cells derived from human exfoliated deciduous teeth (SHED-CM) into the D-galactosamine (D-Gal)-induced rat ALF model improves the liver injury. However, the specific factors in SHED-CM that are responsible for resolving ALF remain unclear. Here we found that depleting SHED-CM of two anti-inflammatory M2 macrophage inducers—monocyte chemoattractant protein-1 (MCP-1) and the secreted ectodomain of sialic acid-binding Ig-like lectin-9 (sSiglec-9)—abolished its ability to resolve rat ALF. Furthermore, treatment with MCP-1/sSiglec-9 alone dramatically improved the survival of ALF rats. This treatment induced anti-inflammatory M2, suppressed hepatocyte apoptosis, and promoted hepatocyte proliferation. Treatment with an M2-depletion reagent (mannosylated clodronate liposomes) suppressed the recovery. In addition, MCP-1 and sSiglec-9 synergistically promoted the M2 differentiation of bone marrow-derived macrophages via CCR2, accompanied by the production of multiple liver-regenerating factors. The conditioned medium from MCP-1/sSiglec-9-activated M2 macrophages, but not from interleukin-4-induced ones, suppressed the D-Gal- and LPS-induced apoptosis of primary hepatocytes and promoted their proliferation in vitro. The unique combination of MCP-1/sSiglec-9 ameliorates rat ALF by inhibiting hepatocellular apoptosis and promoting liver regeneration through the induction of anti-inflammatory/tissue-repairing M2 macrophages. PMID:28272428

  16. Systemic increase in human maternal circulating CD14+CD16- MCP-1+ monocytes as a marker of labor.

    Science.gov (United States)

    Bardou, Marc; Hadi, Tarik; Mace, Guillaume; Pesant, Matthieu; Debermont, Julie; Barrichon, Marina; Wendremaire, Maeva; Laurent, Nicole; Sagot, Paul; Lirussi, Frédéric

    2014-01-01

    To study the influence of pregnancy and labor on the proportion and level of activation of monocyte subpopulations in human pregnancy. Peripheral blood samples were obtained from healthy nonpregnant women (n = 6); women in the third-trimester of healthy pregnancies (n = 18) and women with preterm premature rupture of membranes (n = 46), just before delivery for the last 2 groups. Monocyte subpopulations were characterized by flow cytometry using CD14, CD16, and activation level using macrophage chemoattractant protein-1 (MCP-1) and CCR2 antibodies. The relative proportion of each monocyte subset in nonpregnant women was similar to that in women with healthy or complicated pregnancies. However, pregnancy was associated with a significant decrease in MCP-1 expressing monocytes (79.5% ± 19.8% vs 9.3% ± 6.8% and 11.9% ± 8.3% for nonpregnant, healthy pregnancy, and preterm premature rupture of membranes (respectively, P labor was associated with a return to nonpregnant values for the proportion of MCP-1 expressing monocytes in both normal (74.4% ± 16.9) and preterm premature rupture of membranes pregnancy (68.4% ± 35.6), irrespective of the mode of delivery (vaginal or cesarean section). This was not observed in women who delivered without spontaneous labor onset. CCR-2 (MCP-1 receptor) expression was not modified in monocytes at the time of labor, but was significantly increased in granulocytes (3646 ± 1080 vs 7338 ± 2718 for nonlaboring and laboring preterm premature rupture of membranes, respectively, P labor, our results suggest the downregulation of activation levels of monocytes, via MCP-1 expression might be involved in maternofetal immune tolerance. Monocyte reactivation might be associated with labor. Copyright © 2014 Mosby, Inc. All rights reserved.

  17. FGFR3 promotes angiogenesis-dependent metastasis of hepatocellular carcinoma via facilitating MCP-1-mediated vascular formation.

    Science.gov (United States)

    Liu, Xinyu; Jing, Xiaoqian; Cheng, Xi; Ma, Ding; Jin, Zhijian; Yang, Weiping; Qiu, Weihua

    2016-05-01

    The biological role of fibroblast growth factor receptor 3 (FGFR3) in tumor angiogenesis of hepatocellular carcinoma (HCC) has not been discussed before. Our previous work had indicated FGFR3 was overexpressed in HCC, and silencing FGFR3 in Hu7 cells could regulate tumorigenesis via down-regulating the phosphorylation level of key members of classic signaling pathways including ERK and AKT. In the present work, we explored the role of FGFR3 in angiogenesis-dependent metastasis by using SMMC-7721 and QGY-7703 stable cell lines. Our results indicated FGFR3 could regulate in vitro cell migration ability and in vivo lung metastasis ability of HCC, which was in accordance with increased angiogenesis ability in vitro and in vivo. Using the supernatant from SMMC-7721/FGFR3 cells, we conducted a human angiogenesis protein microarray including 43 angiogenesis factors and found that FGFR3 modulated angiogenesis and metastasis of HCC mainly by promoting the protein level of monocyte chemotactic protein 1 (MCP-1). Silencing FGFR3 by short hairpin RNA (shRNA) could reduce MCP-1 level in lysates and supernatant of QGY-7703 cells and SMMC-7721 cells. Silencing MCP-1 in QGY-7703 or SMMC-7721 cells could induce similar phenotypes compared with silencing FGFR3. Our results suggested FGFR3 promoted metastasis potential of HCC, at least partially if not all, via facilitating MCP-1-mediated angiogenesis, in addition to previously found cell growth and metastasis. MCP-1, a key medium between HCC cells and HUVECs, might be a novel anti-vascular target in HCC.

  18. Using pulse shape analysis to improve the position resolution of a resistive anode microchannel plate detector

    CERN Document Server

    Siwal, Davinder; deSouza, R T

    2015-01-01

    Digital signal processing techniques were employed to investigate the joint use of charge division and risetime analyses for the resistive anode (RA) coupled to a microchannel plate detector (MCP). In contrast to the typical approach of using the relative charge at each corner of the RA, this joint approach results in a significantly improved position resolution. A conventional charge division analysis utilizing analog signal processing provides a position measured resolution of 170 $\\mu$m (FWHM). By using the correlation between risetime and position we were able to obtain a measured resolution of 92 $\\mu$m (FWHM), corresponding to an intrinsic resolution of 64 $\\mu$m (FMHM) for a single Z-stack MCP detector.

  19. Microchannel plate fabrication using glass capillary arrays with Atomic Layer Deposition films for resistance and gain

    Science.gov (United States)

    Popecki, M. A.; Adams, B.; Craven, C. A.; Cremer, T.; Foley, M. R.; Lyashenko, A.; O'Mahony, A.; Minot, M. J.; Aviles, M.; Bond, J. L.; Stochaj, M. E.; Worstell, W.; Elam, J. W.; Mane, A. U.; Siegmund, O. H. W.; Ertley, C.; Kistler, L. M.; Granoff, M. S.

    2016-08-01

    Microchannel plates (MCPs) have been used for many years in space flight instrumentation as fast, lightweight electron multipliers. A new MCP fabrication method combines a glass substrate composed of hollow glass capillary arrays with thin film coatings to provide the resistive and secondary electron emissive properties. Using this technique, the gain, resistance, and glass properties may be chosen independently. Large-area MCPs are available at moderate cost. Secondary emission films of Al2O3 and MgO provide sustained high gain as charge is extracted from the MCP. Long lifetimes are possible, and a total extracted charge of 7 C/cm2 has been demonstrated. Background rates are low because the glass substrate has little radioactive potassium 40. Curved MCPs are easily fabricated with this technique to suit instrument symmetries, simplifying secondary electron steering and smoothing azimuthal efficiency.

  20. Create Your Plate

    Medline Plus

    Full Text Available ... steps to get started: Using your dinner plate, put a line down the middle of the plate. ... vegetables . Now in one of the small sections, put grains and starchy foods. See this list of ...

  1. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate It's simple and effective for both managing diabetes and losing weight. Creating your plate lets ... 2016 Articles from Diabetes Forecast® magazine: wcie-meal-planning, In this section Food Planning Meals Diabetes Meal ...

  2. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal ... Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook ...

  3. Food guide plate

    Science.gov (United States)

    ... chips or cookies. VEGETABLES: MAKE HALF OF YOUR PLATE FRUITS AND VEGETABLES Vegetables can be raw, fresh, ... as a snack. FRUITS: MAKE HALF OF YOUR PLATE FRUITS AND VEGETABLES Fruits can be fresh, canned, ...

  4. Growth Plate Fractures

    Science.gov (United States)

    ... the most widely used by doctors is the Salter-Harris system, described below. Type I Fractures These ... incidence of growth plate fractures peaks in adolescence. Salter-Harris classification of growth plate fractures. AAOS does ...

  5. Create Your Plate

    Medline Plus

    Full Text Available ... Planning Meals Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook ... Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart- ...

  6. Create Your Plate

    Medline Plus

    Full Text Available ... Planning Meals Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook ... Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart- ...

  7. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate It's simple and effective for both managing diabetes and losing weight. Creating your plate lets you still choose the foods you want, but changes the portion sizes so you are getting larger ...

  8. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate It's simple and effective for both managing diabetes and losing weight. Creating your plate lets ... Sleeve Custom jerseys for your Tour de Cure team benefits the cause. Ask the Experts: Learn to ...

  9. 化学镀镍复合添加剂BH的工艺特性%Technological properties of composite stabilizer BH for electroless nickel plating

    Institute of Scientific and Technical Information of China (English)

    鹿轩; 梁颖诗; 张晓明; 林继月; 胡耀红; 赵国鹏

    2013-01-01

    开发了一种由含钼化合物、碘化钾以及邻苯二甲酸酐衍生物组成的复合添加剂BH,讨论了它对化学镀镍液稳定性、镀速以及镀层磷含量、硬度、孔隙率和微观形貌的影响。对测试化学镀镍液稳定性的PdCl2试验标准进行了改进:温度由80°C提高到90°C,PdCl2的浓度由0.1 g/L增加到1.0 g/L。研究结果显示,新标准检验的镀液稳定性差异能较好地反映实际生产中的镀液稳定性差异;当复合添加剂BH的添加量为2.0 mL/L时,化学镀镍层微观形貌得到较大的改善。经过新的PdCl2试验标准检验,该镀液可达到900 s不发生浑浊,镀速为24μm/h,镀层孔隙率0.57个/cm2,磷含量7.3%,硬度520 HV。%A composite additive BH consisting of molybdenum-containing compound, potassium iodide, and phthalic anhydride derivative was developed, and its influence on the stability and deposition rate of electroless nickel plating bath, as well as the phosphorus content, hardness, porosity, and micro-morphology of deposit was discussed. The PdCl2 test standard used for determining stability of electroless nickel plating bath was improved as follows: increasing temperature from 80 °C to 90 °C and PdCl2 concentration from 0.1 g/L to 1.0 g/L. The results indicated that the difference of bath stability tested by the improved method has good relevance with that in practical production. The electroless nickel plating bath with composite additive BH 2.0 mL/L remains stable within 900 s without becoming turbid by testing based on the improved method and produces electroless nickel coatings with improved micro-morphologies at a deposition rate of 24μm/h.The electroless nickel coating obtained has a porosity 0.57 pores/cm2, phosphorus content 7.3%and hardness 520 HV.

  10. Accelerated plate tectonics.

    Science.gov (United States)

    Anderson, D L

    1975-03-21

    The concept of a stressed elastic lithospheric plate riding on a viscous asthenosphere is used to calculate the recurrence interval of great earthquakes at convergent plate boundaries, the separation of decoupling and lithospheric earthquakes, and the migration pattern of large earthquakes along an arc. It is proposed that plate motions accelerate after great decoupling earthquakes and that most of the observed plate motions occur during short periods of time, separated by periods of relative quiescence.

  11. Calculation and comparison between alternate and continuous controlled cooling technology for X65 pipeline steel plate%X65管线钢板交替与连续控冷工艺的计算与比较

    Institute of Scientific and Technical Information of China (English)

    张德丰; 陆建生; 吕建国; 宋鹏; 杜重麟

    2012-01-01

    为减小X65管线钢板控制冷却后的残余应力和翘曲,通过开发线性混合热膨胀模型、拓展Avrami相变动力学模型和应用Leblond的相变诱发塑性(TRIP)模型建立了热力耦合有限元模型,考虑了控冷时的弹塑性变形、热膨胀、相变潜热、相变膨胀、TRIP等所有物理效应.用该模型研究了2种控制冷却工艺下X65管线钢板的温度、残余应力、残余应变及翘曲.结果表明:与连续控冷相比,交替控冷使板的温度进一步降低7℃;上表面一侧的残余拉应力峰值进一步减小44 MPa;下表面一侧的残余总压应变峰值进一步增加0.001;翘曲由0.54×10-3减至0.09×10-3;故交替控冷可降低板内的残余应力,并减小翘曲.%To decrease the residual stress and warping of X65 pipeline steel plate after controlled cooling, a thermo-mechanical coupled FEM model was established according to linear mixture thermal expansion model, modified Avrami transformation dynamics model and Leblond transformation induced plasticity (TRIP) model. All relevant physical effects of elastoplastic deformation, thermal expansion, latent heat, transformation dilatation and TRIP effect were considered in the FEM model. Temperature, residual stress, residual strain and warping of X65 pipeline steel plate were analyzed by the proposed model under two controlled cooling technologies. The results show that the temperature of plate under alternate controlled cooling is 7 ℃ less than that under continuous controlled cooling. The residual tensile stress peak value near top surface is decreased by 44 Mpa with enhanced residual compressive strain peak value of 0.001 near bottom surface, while the warping is reduced from 0. 54 × 10-3 to 0. 09 × 10-3. Alternate controlled cooling can reduce residual stress and warping of plate.

  12. Express of NF-kB65 and MCP-1 in intermittent hypoxia rats%间歇缺氧大鼠 NF-kBp65以及MCP-1的表达

    Institute of Scientific and Technical Information of China (English)

    徐晓梅; 樊荣; 黄晓颖; 林乾顶; 王良兴

    2013-01-01

    Objective To investigate the expression of NF-kBp65 and MCP-1 in serum and heart muscle in intermittent hypoxia rats. Methods There are thirty SD rats were randomly assigned into three groups: control group, intermittent hypoxia group and continuing hypoxia group, which were exposed to air, intermittent hypoxia and continuing hypoxia respectively 8h/d for 35d.Then the blood and heart samples were collected, and the NF-kBp65 and MCP-1 levels in serum and in heart tissue were measured with ELISA and Western blot respectively. Results Compared to the control group the contents of NF-kBp65 and MCP-1 in serum and heart were increased both in intermittent hypoxia group and continuing hypoxia group. Conclusion NF-kBp65 and MCP-1 in heart and blood of intermittent hypoxia rats, which may be associated with the activation of NF-kB by hypoxia.%  目的探讨间歇缺氧对大鼠血清以及心肌中 NF-kBp65以及 MCP-1含量的影响.方法清洁 SD 大鼠30只,随机分成3组(每组10只):正常对照组、间歇缺氧组、持续缺氧组,普通饲料饲养.正常对照组:常压、常氧下饲养;间歇低氧组:每90s一循环,氧舱内低氧浓度维持在6%~8%,持续10s 以上;持续低氧组:氧舱内氧浓度维持在8%~11%.每天早上9:00动物入舱,至下午5:00试验结束,每天持续8h,连续35d.然后经右颈动脉抽血,处死大鼠分离其心脏,采用酶联免疫吸附法(ELISA 法)测定血清中 NF-kBp65以及 MCP-1含量,采用免疫印迹法测定大鼠心肌中 NF-kBp65以及 MCP-1的含量.结果与正常对照组相比,在间歇缺氧组以及持续缺氧组中大鼠血清以及心肌中 NF-kBp65以及 MCP-1的含量明显增加.结论间歇缺氧可导致 NF-kB 的激活,从而导致大鼠血清以及心肌中 NF-kBp65以及 MCP-1的表达增加.

  13. 复杂曲面船体外板非对压多压头成形技术%No-Pair Dins Forming Technology for Complex Curved Surface of Ship Hull Plate

    Institute of Scientific and Technical Information of China (English)

    华剑锋; 胡勇; 王呈方; 刘光武; 周永清

    2011-01-01

    The status of hull plate processing was described in this paper, the multi-point forming technology and its development at home and abroad was introduced. Based on the analysis of advantages and disadvantages of multi-point forming technology, the novel sheet metal forming method was proposed, it is the no-pair dins forming mechanism with square press heads. Combined with the forming process, the principle of the suppression of impression and wrinkling was researched . The experiments on the sheet plate with different thickness were made on the self-made device and the experimental results show it was practical.%文章阐述了船体外板加工的现状,介绍了多点成形技术的原理及在国内外的发展,同时在分析多点成形技术的优缺点的基础上提出了新的板材成形技术即非对压多压头冲压成形技术.结合成形过程系统地研究了这种新成形技术的抑制成形板材压痕、皱折的原理.并利用自主研制开发的弯板实验样机对不同厚度的板材进行成形实验并对实验结果进行了分析,验证了其有效性.

  14. Studies of Leaning-type-air-distributing-plate Loose-leaf Bulk Curing Technology on Flue-cured Tobacco%烟叶背靠式分风板散叶密集烘烤技术研究

    Institute of Scientific and Technical Information of China (English)

    詹吉平; 卢雨; 杜超凡; 童旭华; 王峰吉

    2015-01-01

    The application effects of leaning-type-air-distributing-plate on loose-leaf bulk curing technology were studied in this paper. The results showed that: the application of leaning-type-air-distributing-plate technology on loose-leaf bulk curing increased the tobacco leaves loading capacity by 66.54%. The curing cost of dry tobacco leaves reduced 0.62 yuan per kg. The economic benefit of the cured tobacco leaves of one bulk curing barn increased by 8 559.06 yuan. The ratio of high quality leaves, average price, single leaf weight, output value of the cured tobacco leaves were all higher than that of the control. The smoking quality of it was improved.%研究了背靠式分风板散叶密集烘烤技术在烤烟上的应用效果,结果表明:应用背靠式分风板散叶密集烘烤技术,可增加密集烤房装烟容量61.51%,每千克干烟叶减少烘烤成本0.62元,单炉经济效益增加8559.06元;烤后烟叶上等烟比例、均价、单叶重、产值均高于对照,烟叶感官评吸质量有所提高。

  15. Create Your Plate

    Medline Plus

    Full Text Available ... Reset Plate Share Create Your Plate ! Share: Seven Simple Steps to Create Your Plate It's simple and effective for both managing diabetes and losing ... en.html Have Type 2 Diabetes? Our free program will help you live well. More from diabetes. ...

  16. Obliquity along plate boundaries

    Science.gov (United States)

    Philippon, Mélody; Corti, Giacomo

    2016-12-01

    Most of the plate boundaries are activated obliquely with respect to the direction of far field stresses, as roughly only 8% of the plate boundaries total length shows a very low obliquity (ranging from 0 to 10°, sub-orthogonal to the plate displacement). The obliquity along plate boundaries is controlled by (i) lateral rheological variations within the lithosphere and (ii) consistency with the global plate circuit. Indeed, plate tectonics and magmatism drive rheological changes within the lithosphere and consequently influence strain localization. Geodynamical evolution controls large-scale mantle convection and plate formation, consumption, and re-organization, thus triggering plate kinematics variations, and the adjustment and re-orientation of far field stresses. These geological processes may thus result in plate boundaries that are not perpendicular but oblique to the direction of far field stresses. This paper reviews the global patterns of obliquity along plate boundaries. Using GPlate, we provide a statistical analysis of present-day obliquity along plate boundaries. Within this framework, by comparing natural examples and geological models, we discuss deformation patterns and kinematics recorded along oblique plate boundaries.

  17. The economic payoff for a state-of-the-art high-efficiency flat-plate crystalline silicon solar cell technology

    Science.gov (United States)

    Bickler, Donald B.; Callaghan, W. T.

    In 1986 during the flat-plate solar array project, silicon solar cells 4.0 sq cm in area were fabricated at the Jet Propulsion Laboratory (JPL) with a conversion efficiency of 20.1 percent (AM1.5-global). Sixteen cells were processed with efficiencies measuring 19.5 percent (AM1.5 global) or better. These cells were produced using refined versions of conventional processing methods, aside from certain advanced techniques that bring about a significant reduction in a major mechanism (surface recombination) that limits cell efficiency. Wacker Siltronic p-type float-zone 0.18-ohm-cm wafers were used. Conversion efficiencies in this range have previously been reported by other researchers, but generally on much smaller (0.5 vs. 4.0 cm) devices which have undergone sophisticated and costly processing steps. An economic analysis is presented of the potential payoffs for this approach, using the Solar Array Manufacturing Industry Costing Standards (SAMICS) methodology. The process sequence used and the assumptions made for capturing the economies of scale are presented.

  18. 夹层板系统碰撞性能数值仿真分析技术%Numerical simulation analysis technology for sandwich plate system crashworthiness

    Institute of Scientific and Technical Information of China (English)

    周红; 张延昌; 岳亚霖; 刘昆

    2013-01-01

    为促进夹层板系统(Sandwich Plate System,SPS)在船舶耐撞结构设计中的应用,用Abaqus分析SPS在碰撞载荷下的数值模型化技术,包括夹芯层和面板的建模方式、连接形式和网格尺寸.根据该技术研究SPS在碰撞冲击载荷作用下的力学性能,如结构损伤变形、碰撞力和结构吸能等.结果表明,SPS建模采用壳-体混合模型(即上、下面板采用壳单元,夹芯层采用体单元)较合理;夹芯层与面板之间采用绑定连接较合理;SPS具有良好的耐撞性能.

  19. Detection efficiency of microchannel plates for e(-) and π(-) in the momentum range from 17.5 to 345 MeV/c.

    Science.gov (United States)

    Tulej, M; Meyer, S; Lüthi, M; Lasi, D; Galli, A; Desorgher, L; Hajdas, W; Karlsson, S; Kalla, L; Wurz, P

    2015-08-01

    High-energy e(-) and π(-) were measured by the multichannel plate (MCP) detector at the PiM1 beam line of the High Intensity Proton Accelerator Facilities located at the Paul Scherrer Institute, Villigen, Switzerland. The measurements provide the absolute detection efficiencies for these particles: 5.8% ± 0.5% for electrons in the beam momenta range 17.5-300 MeV/c and 6.0% ± 1.3% for pions in the beam momenta range 172-345 MeV/c. The pulse height distribution determined from the measurements is close to an exponential function with negative exponent, indicating that the particles penetrated the MCP material before producing the signal somewhere inside the channel. Low charge extraction and nominal gains of the MCP detector observed in this study are consistent with the proposed mechanism of the signal formation by penetrating radiation. A very similar MCP ion detector will be used in the Neutral Ion Mass (NIM) spectrometer designed for the JUICE mission of European Space Agency (ESA) to the Jupiter system, to perform measurements of the chemical composition of the Galilean moon exospheres. The detection efficiency for penetrating radiation determined in the present studies is important for the optimisation of the radiation shielding of the NIM detector against the high-rate and high-energy electrons trapped in Jupiter's magnetic field. Furthermore, the current studies indicate that MCP detectors can be useful to measure high-energy particle beams at high temporal resolution.

  20. Angular shear plate

    Science.gov (United States)

    Ruda, Mitchell C [Tucson, AZ; Greynolds, Alan W [Tucson, AZ; Stuhlinger, Tilman W [Tucson, AZ

    2009-07-14

    One or more disc-shaped angular shear plates each include a region thereon having a thickness that varies with a nonlinear function. For the case of two such shear plates, they are positioned in a facing relationship and rotated relative to each other. Light passing through the variable thickness regions in the angular plates is refracted. By properly timing the relative rotation of the plates and by the use of an appropriate polynomial function for the thickness of the shear plate, light passing therethrough can be focused at variable positions.

  1. Microchannel Plate Imaging Detectors for the Ultraviolet

    Science.gov (United States)

    Siegmund, O. H. W.; Gummin, M. A.; Stock, J.; Marsh, D.

    1992-01-01

    There has been significant progress over the last few years in the development of technologies for microchannel plate imaging detectors in the Ultraviolet (UV). Areas where significant developments have occurred include enhancements of quantum detection efficiency through improved photocathodes, advances in microchannel plate performance characteristics, and development of high performance image readout techniques. The current developments in these areas are summarized, with their applications in astrophysical instrumentation.

  2. Ação do 1-metilciclopropeno (1-MCP na vida de prateleira da banana 'maçã' Action of 1-methylcyclopropene (1-MCP on shelf life of 'apple' banana

    Directory of Open Access Journals (Sweden)

    Ana Carla Marques Pinheiro

    2005-04-01

    Full Text Available Objetivou-se avaliar o efeito do 1-metilciclopropeno (1-MCP, em diferentes concentrações, sobre a vida pós-colheita e sob as variáveis associadas aos atributos de qualidade de banana 'Maçã'. Frutos verde-maturos foram submetidos a cinco concentrações de 1-MCP (0; 50; 100; 150 e 200 etaL.L-1, por 12 horas, e foram analisados durante o amadurecimento sob condição ambiente (20±1ºC e 80±5% UR. O tratamento com 50 etaL.L-1 de 1-MCP atrasou o início do amadurecimento das bananas em aproximadamente 8 dias, baseando-se nas primeiras mudanças de coloração da casca, enquanto os tratamentos 100; 150 e 200 etaL.L-1 atrasaram-no em aproximadamente 10 dias. Observou-se, durante o amadurecimento, o amaciamento dos frutos, associado à conversão de amido em açúcares e ao aumento na solubilização péctica e na atividade da pectinametilesterase (PME e poligalacturonase (PG. A aplicação de 50 etaL.L-1de 1-MCP é a mais adequada por promover a extensão da vida de prateleira de bananas 'Maçã', preservando sua qualidade com base nas análises de açúcares solúveis totais, pectinas total e solúvel, firmeza e aparência externa ao final do armazenamento.The objective of this work was to evaluate the influence of the 1-MCP, at different concentrations, on quality and shelf life of 'Apple' banana. Green mature fruits were submitted to five concentrations of 1-MCP (0, 50, 100, 150 and 200 etaL.L-1, for 12 hours and analyzed during the ripening at room temperature (20ºC ± 1 and 80% ± 5 RH . The 1-MCP at 50 etaL.L-1 delayed, in 8 days, the begining of the ripening, based in the first changes of peel color, whereas 100, 150 and 200 etaL.L-1 treatments delayed the begining of the ripening in 10 days, in comparison to the control. The softening of the fruits, associated to the conversion of starch in sugar and the increasing in the pectic solubilization and activity of pectinmethylsterase and polygalacturonase, was observed during the ripening

  3. Effect of 1-MCP-β-CD on Vase Quality of Cut Carnation Flowers%1-MCP-β-环糊精对香石竹切花保鲜作用的研究

    Institute of Scientific and Technical Information of China (English)

    陈均志; 王瑾; 邵超群

    2009-01-01

    对香石竹切花(Dianthus caryophyllus L.)用不同体积浓度的1-MCP-β-环糊精溶液处理不同的时间,观察其外观形态品质和生理生化指标,得知以50 mg/L的1-MCP-β-环糊精溶液在7 m3的密闭体系中处理8 h效果最佳.能极大提高香石竹切花的观赏价值,减少萎蔫程度,延缓开放,延迟香石竹切花叶片质膜相对透性下降,并对叶片叶绿素含量变化有一定的影响.

  4. A Fault-Tolerant Filtering Algorithm for SINS/DVL/MCP Integrated Navigation System

    Directory of Open Access Journals (Sweden)

    Xiaosu Xu

    2015-01-01

    Full Text Available The Kalman filter (KF, which recursively generates a relatively optimal estimate of underlying system state based upon a series of observed measurements, has been widely used in integrated navigation system. Due to its dependence on the accuracy of system model and reliability of observation data, the precision of KF will degrade or even diverge, when using inaccurate model or trustless data set. In this paper, a fault-tolerant adaptive Kalman filter (FTAKF algorithm for the integrated navigation system composed of a strapdown inertial navigation system (SINS, a Doppler velocity log (DVL, and a magnetic compass (MCP is proposed. The evolutionary artificial neural networks (EANN are used in self-learning and training of the intelligent data fusion algorithm. The proposed algorithm can significantly outperform the traditional KF in providing estimation continuously with higher accuracy and smoothing the KF outputs when observation data are inaccurate or unavailable for a short period. The experiments of the prototype verify the effectiveness of the proposed method.

  5. Epstein-Barr virus induces MCP-1 secretion by human monocytes via TLR2.

    Science.gov (United States)

    Gaudreault, Eric; Fiola, Stéphanie; Olivier, Martin; Gosselin, Jean

    2007-08-01

    Epstein-Barr virus (EBV) is a gammaherpesvirus infecting the majority of the human adult population in the world. TLR2, a member of the Toll-like receptor (TLR) family, has been implicated in the immune responses to different viruses including members of the herpesvirus family, such as human cytomegalovirus, herpes simplex virus type 1, and varicella-zoster virus. In this report, we demonstrate that infectious and UV-inactivated EBV virions lead to the activation of NF-kappaB through TLR2 using HEK293 cells cotransfected with TLR2-expressing vector along with NF-kappaB-Luc reporter plasmid. NF-kappaB activation in HEK293-TLR2 cells (HEK293 cells transfected with TLR2) by EBV was not enhanced by the presence of CD14. The effect of EBV was abrogated by pretreating HEK293-TLR2 cells with blocking anti-TLR2 antibodies or by preincubating viral particles with neutralizing anti-EBV antibodies 72A1. In addition, EBV infection of primary human monocytes induced the release of MCP-1 (monocyte chemotactic protein 1), and the use of small interfering RNA targeting TLR2 significantly reduced such a chemokine response to EBV. Taken together, these results indicate that TLR2 may be an important pattern recognition receptor in the immune response directed against EBV infection.

  6. Activated V gamma 9V delta 2 T cells trigger granulocyte functions via MCP-2 release.

    Science.gov (United States)

    Agrati, Chiara; Cimini, Eleonora; Sacchi, Alessandra; Bordoni, Veronica; Gioia, Cristiana; Casetti, Rita; Turchi, Federica; Tripodi, Marco; Martini, Federico

    2009-01-01

    Vgamma9Vdelta2 T cells display a broad antimicrobial activity by directly killing infected cells and by inducing an effective adaptive immune response. The activation of Vgamma9Vdelta2 T cells by aminobisphosphonate drugs such as zoledronic acid (ZOL) results in a massive release of cytokines and chemokines that may induce a bystander activation of other immune cells. The aim of this work was to evaluate the ability of soluble factors released by ZOL-activated Vgamma9Vdelta2 T cells to induce granulocyte activation. We showed that soluble factors released by ZOL-stimulated Vgamma9Vdelta2 T cells activate granulocytes by inducing their chemotaxis, phagocytosis, and alpha-defensins release. Proteomic analysis allowed us to identify a number of cytokines and chemokines specifically released by activated Vgamma9Vdelta2 T cells. Moreover, MCP-2 depletion by neutralizing Ab revealed a critical role of this chemokine in induction of granulocyte alpha-defensins release. Altogether, these data show a Vgamma9Vdelta2-mediated activation of granulocytes through a bystander mechanism, and confirm the wide ability of Vgamma9Vdelta2 T-lymphocytes in orchestrating the immune response. In conclusion, an immune modulating strategy targeting Vgamma9Vdelta2 T cells may represent a key switch to induce an effective and well-coordinated immune response, and can be proposed as a way to strengthen the immune competence during infectious diseases.

  7. MCP detector read out with a bare quad Timepix at kilohertz frame rates

    Science.gov (United States)

    Vallerga, J.; Raffanti, R.; Tremsin, A.; McPhate, J.; Siegmund, O.

    2011-01-01

    The existing Berkeley neutron sensitive MCP/Timepix hybrid detector has been very successful at demonstrating energy resolved spatial imaging with a single Timepix ASIC read out at a ~ 30 Hz frame rate where each neutron's position and time (energy) is determined (X,Y,E). By increasing the detector format using a quad arrangement of Timepix readouts and increasing the frame rate to 1 kHz, we can increase our total event throughput by a factor of 120, thereby taking full advantage of the high fluxes of modern pulsed neutron sources (106 n cm-2 s-1). The key to this conversion is a new design for the ASIC readout, called the Berkeley Quad Timepix detector, consisting of 3 major subsystems. The first is a quad (2 × 2) bare Timepix ASIC board mounted directly behind the neutron sensitive MCPs in a hermetic vacuum enclosure with a sapphire window. The data from the Timepix ASICs flow to the second subsystem called the Interface board whose field programmable gate array (FPGA) rearranges and converts the digital bit stream to LVDS logic levels before sending downstream to the third subsystem, the Roach board. The Roach board is also FPGA based, and takes the data from all the ASICs and analyses the frames to extract information on the input events to pass on to the host PC. This paper describes in detail the hardware and firmware designs to accomplish this task.

  8. Simulation of the effects of coated material SEY property on output electron energy distribution and gain of microchannel plates

    Science.gov (United States)

    Chen, Lin; Wang, Xingchao; Tian, Jinshou; Liu, Chunliang; Liu, Hulin; Chen, Ping; Wei, Yonglin; Sai, Xiaofeng; Sun, Jianning; Si, Shuguang; Wang, Xing; Lu, Yu; Tian, Liping; Hui, Dandan; Guo, Lehui

    2016-12-01

    To obtain a high spatial resolution of a image intensifier based on microchannel plate (MCP), the long tail in the exit energy distribution of the output electrons (EDOE) is undesirable. The existing solution is increasing the penetration depth of the MCP output electrode, which will result in a serious gain reduction. Coating the MCP output electrode with efficient secondary electron yield (SEY) materials is supposed to be an effective approach to suppress the unfavorable tail component in the EDOE without negative effects on the gain. In our work, a three-dimensional MCP single channel model is developed in CST STUDIO SUITE to systematically investigate the dependences of the EDOE and the gain on the SEY property of the coated material, based on the Finite Integral Technique and Monte Carlo method. The results show that besides the high SEY of the coated material, the low incident energy corresponding to the peak SEY is another essential element affecting the electron yield in the final stage of multiplication and suppressing the output energy spread.

  9. Imaging characteristics of the Extreme Ultraviolet Explorer microchannel plate detectors

    Science.gov (United States)

    Vallerga, J. V.; Kaplan, G. C.; Siegmund, O. H. W.; Lampton, M.; Malina, R. F.

    1989-01-01

    The Extreme Ultraviolet Explorer (EUVE) satellite will conduct an all-sky survey over the wavelength range from 70 A to 760 A using four grazing-incidence telescopes and seven microchannel-plate (MCP) detectors. The imaging photon-counting MCP detectors have active areas of 19.6 cm2. Photon arrival position is determined using a wedge-and-strip anode and associated pulse-encoding electronics. The imaging characteristics of the EUVE flight detectors are presented including image distortion, flat-field response, and spatial differential nonlinearity. Also included is a detailed discussion of image distortions due to the detector mechanical assembly, the wedge-and-strip anode, and the electronics. Model predictions of these distortions are compared to preflight calibration images which show distortions less than 1.3 percent rms of the detector diameter of 50 mm before correction. The plans for correcting these residual detector image distortions to less than 0.1 percent rms are also presented.

  10. Effect of One-methylcyclopropene (1-MCP) and chlorine dioxide (ClO2) on preservation of green walnut fruit and kernel traits.

    Science.gov (United States)

    Jiang, Liuqing; Feng, Wenyu; Li, Fang; Xu, Jingying; Ma, Yanping; Ma, Huiling

    2015-01-01

    The effect of the ethylene receptor competitor 1-methylcyclopropene (1-MCP) and the legally approved disinfectant chlorine dioxide (ClO2) on preservation of the green walnut fruit during storage was investigated. Green Chinese walnut fruit cv. Xilin No.2 was harvested on commercial maturity and stored at 0-1 °C after the fruit was treated by water (control), 80 mg L(-1)ClO2 (ClO2), 0.5 μL L(-1)1-MCP (1-MCP), or combination treatment of 80 mg L(-1) ClO2 with either 0.1 μL L(-1) 1-MCP (0.1 1-MCP+ ClO2) or 0.5 μL L(-1) 1-MCP (0.5 1-MCP+ ClO2). During storage, respiration, ethylene production, phenolics content, antioxidative activity, weight changes, decay of the fruit and kernel traits of acid value, peroxide value,free fatty were measured. All treatments decreased postharvest respiration intensity in different degrees and inhibited ethylene production peak. ClO2 increased the total phenol and flavonoid content of the green fruit compared with other treatments and the control (P < 0.05), but not did the total antioxidant activity for this treatment. After 42-day storage, ClO2 remained higher fresh weight and lower decay index than control, while 1-MCP increased the fruit decay index. Final acid values of kernel from ClO2, control and 0.1 1-MCP+ ClO2 were not different from their initial values, which from 0.5 1-MCP increased. Final peroxide value for kernel from ClO2 showed no change during storage but increased at least 1.0-fold for other treatments. ClO2 preserved 99.9 % of initial free fatty acid, similar to that for the control (99.8 %), whereas 0.5 1-MCP preserved only 95.7 %. ClO2 is of potential in decay retardation and kernel traits maintenance of green walnut fruit, whereas the 1-MCP has a negative effect for decay control on walnut.

  11. Plasma cytokines eotaxin, MIP-1α, MCP-4, and vascular endothelial growth factor in acute lower respiratory tract infection

    DEFF Research Database (Denmark)

    Relster, Mette Marie; Holm, Anette; Pedersen, Court

    2017-01-01

    Major overlaps of clinical characteristics and the limitations of conventional diagnostic tests render the initial diagnosis and clinical management of pulmonary disorders difficult. In this pilot study, we analyzed the predictive value of eotaxin, macrophage inflammatory protein 1 alpha (MIP-1α...... to predict the etiology and severity. Eotaxin and MCP-4 were significantly lower in patients with C-reactive protein ≥100, and MIP-1α was significantly higher in the patients with CURB-65 > 3, but the predictive power was low. In conclusion, further evaluation, including more patients, is required to assess...... the full potential of eotaxin, MCP-4, MIP-1α, and VEGF as biomarkers for LRTI because of their low predictive power and a high interindividual variation of cytokine levels....

  12. Aumento da expressão do MCP-1 coroidal e escleral em modelo experimental de hipercolesterolemia

    Directory of Open Access Journals (Sweden)

    Rogil José de Almeida Torres

    2012-02-01

    Full Text Available OBJETIVO: O objetivo deste trabalho é demonstrar experimentalmente que a dieta rica em colesterol provoca aumento da expressão da MCP-1 na coroide e esclera. MÉTODO: Coelhos New Zealand foram organizados em dois grupos: GN (grupo dieta normal, composto por 8 coelhos (8 olhos, recebeu ração padrão para coelhos, durante 4 semanas; GH (grupo hipercolesterolêmico, composto por 13 coelhos (13 olhos, recebeu dieta rica em colesterol a 1% por 8 semanas. Foi realizada a dosagem sérica de colesterol total, triglicerídeos, HDL colesterol, glicemia de jejum no início do experimento e no momento da eutanásia. Ao final da 8ª semana para o GH e 4ª semana para o GN foi realizada a eutanásia dos animais e os olhos foram submetidos à análise imuno-histoquímica com o anticorpo anti-MCP-1. RESULTADOS: A dieta provocou significativo aumento do colesterol total e triglicerídeos do GH em relação ao GN (p<0,001. Houve significativo aumento da expressão da MCP-1 na coroide e esclera dos animais do GH em relação ao GN (p<0,001. CONCLUSÃO: Este estudo demonstrou que a dieta hipercolesterolêmica em coelhos induz ao aumento da expressão do MCP-1 na coroide e esclera.

  13. Association of MCP-1-2518A/G polymorphism with susceptibility to autoimmune diseases: a meta-analysis.

    Science.gov (United States)

    Chen, Si; Deng, Chuiwen; Hu, Chaojun; Li, Jing; Wen, Xiaoting; Wu, Ziyan; Li, Yuan; Zhang, Fengchun; Li, Yongzhe

    2016-05-01

    We performed a meta-analysis to estimate whether combined evidence shows the association between the MCP-1-2518A/G polymorphism and susceptibility to autoimmune diseases. Relevant articles dated to July 2014 were acquired from the PubMed, EMBASE, ISI, and CNKI databases. The number of the genotypes and/or alleles for the MCP-1-2518A/G in cases and control subjects was extracted, and statistical analysis was conducted using STATA 11.2 software. Summary odds ratios (ORs) with their 95 % confidence intervals (95 % CIs) were used to calculate the risk of autoimmune diseases with the MCP-1-2518A/G. Significant increased risk of autoimmune diseases could be found for A allele vs. G allele (OR = 1.616, 95 % CI 1.027-2.542, P = 0.038) and AA + AG vs. GG (OR = 1.616, 95 % CI 1.027-2.542, P = 0.038) in Asian patients with rheumatoid arthritis (RA), and for A allele vs. G allele (OR = 1.383, 95 % CI 1.142-1.676, P = 0.022) and AA vs. AG + GG (OR = 1.575, 95 % CI 1.361-1.823, P < 0.001) in European patients with Crohn's disease (CD). In addition, when comparison of European patients with lupus nephritis (LN) and without LN, significant association between patients with LN and without LN also could be found for AA vs. AG + GG (OR = 0.713, 95 % CI 0.545-0.933, P = 0.014). This meta-analysis showed that the MCP-1-2518-A allele confers susceptibility to Asian patients with RA and European patients with CD.

  14. Alteration of Endothelin 1, MCP-1 and Chromogranin A in patients with atrial fibrillation undergoing pulmonary vein isolation.

    Science.gov (United States)

    Lackermair, K; Clauss, S; Voigt, T; Klier, I; Summo, C; Hildebrand, B; Nickel, T; Estner, H L; Kääb, S; Wakili, R; Wilbert-Lampen, U

    2017-01-01

    The relation between arrhythmias and stress is known. The aim of our current study was to elucidate whether plasma levels of previously described stress parameters are altered in highly symptomatic patients with atrial fibrillation (AF) per se and in patients undergoing ablation therapy by pulmonary vein isolation (PVI). 96 patients with AF undergoing PVI were recruited. Plasma levels of Endothelin-1 (ET-1), MCP-1 and Chromogranin-A (CGA) were measured before and three months after ablation completed with clinical follow-up with respect to AF recurrence. Additionally, we examined 40 healthy age- and sex-matched volunteers as a reference. Symptomatic AF patients showed increased levels of ET-1 compared to healthy controls (2.62pg/ml vs. 1.57pg/ml; pPVI (2.96pg/ml vs. 2.57pg/ml;p = 0.02). The temporal comparison revealed decreased ET-1 levels in patients without (2.57pg/ml vs. 2.33pg/ml; pPVI. Baseline MCP-1 was increased in AF patients vs. controls (268pg/ml vs. 227 pg/ml; p = 0.03). Both groups, with and without AF after PVI, showed an increase of MCP-1 compared to baseline (268pg/ml vs. 349pg/ml;pPVI showed an increase of CGA (14.2ng/ml vs. 20.7ng/ml;pPVI. Our study demonstrated dysregulated levels of ET-1, MCP-1 and CGA in symptomatic AF patients. We could demonstrate an association between ET-1 to presence or absence of AF. Furthermore, we could show that a decrease of ET-1 as well as an increase of CGA after PVI, representing a trend towards control cohort levels, were both associated with restoration of sinus rhythm. These results provide new insights into the role of stress-related biomarkers in AF and AF treatment by ablation therapy.

  15. Interaction of vascular smooth muscle cells and monocytes by soluble factors synergistically enhances IL-6 and MCP-1 production.

    Science.gov (United States)

    Chen, Li; Frister, Adrian; Wang, Song; Ludwig, Andreas; Behr, Hagen; Pippig, Susanna; Li, Beibei; Simm, Andreas; Hofmann, Britt; Pilowski, Claudia; Koch, Susanne; Buerke, Michael; Rose-John, Stefan; Werdan, Karl; Loppnow, Harald

    2009-04-01

    Inflammatory mechanisms contribute to atherogenesis. Monocyte chemoattractant protein (MCP)-1 and IL-6 are potent mediators of inflammation. Both contribute to early atherogenesis by luring monocytes and regulating cell functions in the vessel wall. MCP-1 and IL-6 production resulting from the interaction of invading monocytes with local vessel wall cells may accelerate atherosclerosis. We investigated the influence of the interaction of human vascular smooth muscle cells (SMCs) with human mononuclear cells (MNCs) or monocytes on IL-6 and MCP-1 production in a coculture model. Interaction synergistically enhanced IL-6 and MCP-1 production (up to 30- and 10-fold, respectively) compared with separately cultured cells. This enhancement was mediated by CD14-positive monocytes. It was dependent on the SMC-to-MNC/monocyte ratio, and as few as 0.2 monocytes/SMC induced the synergism. Synergistic IL-6 production was observed at the protein, mRNA, and functional level. It was mediated by soluble factors, and simultaneous inhibition of IL-1, TNF-alpha, and IL-6 completely blocked the synergism. IL-1, TNF-alpha, and IL-6 were present in the cultures. Blockade of the synergism by soluble glycoprotein 130Fc/soluble IL-6 receptor, as well as the induction of synergistic IL-6 production by costimulation of SMCs with IL-1, TNF-alpha, and hyper-IL-6, suggested the involvement of IL-6 trans-signaling. The contribution of IL-6 was consistent with enhanced STAT3 phosphorylation. The present data suggest that SMC/monocyte interactions may augment the proinflammatory status in the tissue, contributing to the acceleration of early atherogenesis.

  16. Conceptions et usages des plates-formes de formation, Revue Sciences et Technologies de l'Information et de la Communication pour l'\\'Education et la Formation

    CERN Document Server

    George, Sébastien

    2006-01-01

    Educative platforms are at the heart of the development of online education. They can not only be reduced to technological aspects. Underlying models impact teaching and learning from the preparing of lessons to the learning sessions. Research related to these platforms are numerous and their stakes are important. For these reasons, we launched a call to a special issue on "Designs and uses of educative platforms" An educative platform is a computer system designed to automate various functions relating to the organization of the course, to the management of their content, to the monitoring of learners and supervision of persons in charge of various formations (Office de la langue fran\\c{c}aise, 2005). So educative platforms are Learning Management Systems (LMS) which are specific to education contexts.

  17. Resposta da aplicação do 1-MCP em frutos de mamoeiro 'Golden' em diferentes estádios de maturação Responses of 1-MCP applications in 'Golden' papaya fruits on differents maturation stages

    Directory of Open Access Journals (Sweden)

    Maximiliano Silva de Souza

    2009-09-01

    Full Text Available O estudo de fatores que influenciam no processo de amadurecimento é fundamental para o planejamento do processo de comercialização, principalmente em frutos com padrão de respiração climatérico e perecível, como é o caso do mamão. Nesse trabalho, avaliou-se o efeito da aplicação do 1-MCP (1-metilciclopropeno sobre o amadurecimento de frutos de mamoeiro nos estádios 0; 1 e 2 de maturação. O 1-MCP diminui a produção de etileno (≈79% e a taxa respiratória (≈45%, principalmente em frutos no estádio 0 de maturação. O uso deste inibidor da ação do etileno retardou a perda de coloração verde da casca dos frutos, principalmente em frutos nos estádios 0 e 1 de maturação. Houve redução na perda de firmeza do fruto e do mesocarpo nos estádios 1 e 2. Entretanto, em frutos no estádio 0 de maturação, a firmeza do mesocarpo manteve-se alta, o que pode comprometer a aceitação destes frutos pelo consumidor. O teor de sólidos solúveis não foi influenciado pela aplicação do 1-MCP. O efeito do 1-MCP na redução da atividade das enzimas PME e PG foi maior em frutos nos estádios 0 e 1 de maturação em comparação a frutos no estádio 2 de maturação. A atividade da PME demonstrou crescente aumento ao longo do período de armazenamento, porém a atividade da PG permaneceu baixa ao longo dos cinco primeiros dias, com aumento posterior. Os resultados mostraram que a PME exerce influência significativa na perda de firmeza da polpa nos primeiros dias, com atuação posterior da PG. O 1-MCP mostrou-se eficiente em retardar o processo de amadurecimento de frutos de mamoeiro, tornando-se mais eficiente quando associado a estádios de maturação iniciais.The study of factors that influence the process of ripening is critical for planning the marketing process, mainly in standard breathing climacteric and perishing fruits, as it is the case of papaya. In this work it was evaluated the effect of the application of 1-MCP (1

  18. Generalized Fibonacci zone plates

    CERN Document Server

    Ke, Jie; Zhu, Jianqiang

    2015-01-01

    We propose a family of zone plates which are produced by the generalized Fibonacci sequences and their axial focusing properties are analyzed in detail. Compared with traditional Fresnel zone plates, the generalized Fibonacci zone plates present two axial foci with equal intensity. Besides, we propose an approach to adjust the axial locations of the two foci by means of different optical path difference, and further give the deterministic ratio of the two focal distances which attributes to their own generalized Fibonacci sequences. The generalized Fibonacci zone plates may allow for new applications in micro and nanophotonics.

  19. The impacting filter bank design for MCP-EBPSK multicarrier demodulation%用于多路MCP-EBPSK信号解调的冲击滤波器组设计

    Institute of Scientific and Technical Information of China (English)

    陈志敏; 吴乐南; 陈贤卿

    2012-01-01

    修正的随机极性连续相位扩展的二元相移键控调制(MCP-EBPSK)通过随机化调制指数的符号,并加入功率谱调节系数,进一步降低了连续相位扩展的二元相移键控(CP-EBPSK)调制信号功率谱中的线谱分量,使得功率谱占用带宽更窄,信息传输更加的高效高速.多载波作为高频谱利用率的复用调制方式,与MCP-EBPSK结合势必会带来更高的系统性能,因此本文对用于解调单路MCP-EBPSK信号的冲击滤波器进行初步改进,通过添加陷波零点来抑制旁路干扰,设计出带陷波的冲击滤波器组.引入量子粒子群优化算法对加入陷波的冲击滤波器组进行优化得到滤波器组系数,仿真显示即使时频混叠的子载波间不满足正交关系,利用各冲击滤波器中心频率处极陡峭的陷波选频特性依然可以实现各子载波的正确解调.因此,设计的冲击滤波器组可以用于子载波无保护间隔的多路MCP-EBPSK信号解调.%The modified pseudo-random extended binary phase shift keying with continous phase ( MCP-EBPSK) could effectively reduce the spectral line compared with the continuous phase extended BPSK( CP-EBPSK) , which could narrow the power spectrum by adding the modified coefficients and randomizing the sign of the modulation index of CP-EBPSK, finally realized the efficient and high data rate transmission. Multiplexing as a high spectral efficiency technique, combined with the MCP-EBPSK would certainly bring better performance. In this paper we improved the impacting filter and designed the filter bank by adding zeros to the impacting filters at the notch frequencies to depress the inter-channel interference (ICI). Use the QPSO (Quantum-behaved Particle Swarm Optimization) algorithm to obtain the filter bank's parameters, the simulation shown that though the subcarriers were time-frequency aliasing and nonorthogonal, the impacting filter bank could separate the composite signal and demodulated properly

  20. CCL2/MCP-I genotype-phenotype relationship in latent tuberculosis infection.

    Directory of Open Access Journals (Sweden)

    Rabia Hussain

    Full Text Available Among the known biomarkers, chemokines, secreted by activated macrophages and T cells, attract groups of immune cells to the site of infection and may determine the clinical outcome. Association studies of CCL-2/MCP-1 -2518 A/G functional SNP linked to high and low phenotypes with tuberculosis disease susceptibility have shown conflicting results in tuberculosis. Some of these differences could be due the variability of latent infection and recent exposure in the control groups. We have therefore carried out a detailed analysis of CCL-2 genotype SNP -2518 (A/G transition with plasma CCL-2 levels and related these levels to tuberculin skin test positivity in asymptomatic community controls with no known exposure to tuberculosis and in recently exposed household contacts of pulmonary tuberculosis patients. TST positivity was linked to higher concentrations of plasma CCL2 (Mann Whitney U test; p = 0.004 and was more marked when the G allele was present in TST+ asymptomatic controls (A/G; p = 0.01. Recent exposure also had a significant effect on CCL-2 levels and was linked to the G allele (p = 0.007. Therefore association studies for susceptibility or protection from disease should take into consideration the PPD status as well as recent exposure of the controls group used for comparison. Our results also suggest a role for CCL-2 in maintaining the integrity of granuloma in asymptomatic individuals with latent infection in high TB burden settings. Therefore additional studies into the role of CCL-2 in disease reactivation and progression are warranted.

  1. Semiconductor Yield Analysis and Multi-Chip Package (MCP) Die Pairing Optimization using Machine Learning

    Institute of Scientific and Technical Information of China (English)

    Randall Goodwin; Russell Miller; Eugene Tuv; Alexander Borisov

    2006-01-01

    Machine Learning, Artificial Intelligence (AI) and Statistical Learning are related mathematical fields which utilize computer algorithms to create models for the purposes of data description and/or prediction. Some well known examples include biometric identification and authorization systems, speech recognition and user targeted internet advertising. Statistical Learning, which we will use in this paper, also has many applications in semiconductor manufacturing.Some of the challenging characteristics of semiconductor data include high dimensionality, mixtures of categorical and numeric data, non-randomly missing data, non-Gaussian and multimodal distributions, nonlinear complex relationships, noise, outliers and temporal dependencies. These challenges are becoming particularly acute as the quantity of available data increases and the ability to trace lots, wafers, die, and packages throughout the full fab, wafer test, assembly and final test manufacturing flow improves. Statistical-learning techniques are applied to address these challenges. In this paper we discuss the advancement and applications of Tree based classification and regression methods to semiconductor data. We begin the paper with a description of the problem, followed by and overview of the statistical-learning techniques we use in our case studies. We then describe how the challenges presented by semiconductor data were addressed with original extensions to tree-based and kernel-based methods. Next, we review four case studies: home sales price prediction, signal identification/separation, final speed bin classification and die pairing optimization for Multi-Chip Packages (MCP). Results from the case studies demonstrate how statistical-learning addresses the challenges presented by semiconductor manufacturing data and enables improved data discovery and prediction when compared to traditional statistical approaches.

  2. 桥上18号板式高速道岔施工技术%Construction Technology of 18# Plate Type High-speed Turnout on Bridge

    Institute of Scientific and Technical Information of China (English)

    陈永利

    2012-01-01

    High-speed turnout of 18# is widely applied in rapid transit railways in china,such as BeiJing-Tianjin Railway,Wuhan-Guangzhou Railway and Beijing-Shanghai Railway.This paper elaborates the composition,construction technology,key points and difficulty of construction and control measure of 18# High-speed turnout based on the fabricating yard of Hangzhou-Ningbo Yuci elevated station turnout.%18号板式高速道岔在我国高速铁路中得到了广泛的应用,先后应用在京津、武广、京沪等国家主干铁路线。现结合杭甬客专余慈高架车站道岔施工,对18号板式高速道岔的组成、施工工艺、施工重点难点以及安全、质量卡控措施等方面进行阐述。

  3. Antifungal activity of 1-methylcyclopropene (1-MCP) against anthracnose (Colletotrichum gloeosporioides) in postharvest mango fruit and its possible mechanisms of action.

    Science.gov (United States)

    Xu, Xiangbin; Lei, Huanhuan; Ma, Xiuyan; Lai, Tongfei; Song, Hongmiao; Shi, Xuequn; Li, Jiangkuo

    2017-01-16

    Anthracnose caused by Colletotrichum gloeosporioides is one of the most important postharvest diseases in mango fruit, often causing huge economic losses. In this study, the effect of 1-methylcyclopropene (1-MCP) against anthracnose in postharvest mango fruit and the mechanisms involved were investigated. 1-MCP induced reactive oxygen species (ROS) generation, damaged the mitochondria and destroyed the integrity of plasma membrane of spores of C. gloeosporioides, significantly suppressing spore germination and mycelial growth of C. gloeosporioides. 1-MCP also decreased the decay incidence and lesion expansion of mango fruit caused by C. gloeosporioides. For the first time this study demonstrated that 1-MCP suppressed anthracnose of postharvest mango fruit by directly inhibiting spore germination and mycelial growth of C. gloeosporioides, thus providing a promising strategy for disease control. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Technology.

    Science.gov (United States)

    Online-Offline, 1998

    1998-01-01

    Focuses on technology, on advances in such areas as aeronautics, electronics, physics, the space sciences, as well as computers and the attendant progress in medicine, robotics, and artificial intelligence. Describes educational resources for elementary and middle school students, including Web sites, CD-ROMs and software, videotapes, books,…

  5. Spiral ligament fibrocyte-derived MCP-1/CCL2 contributes to inner ear inflammation secondary to nontypeable H. influenzae-induced otitis media

    Directory of Open Access Journals (Sweden)

    Lim David J

    2010-10-01

    Full Text Available Abstract Background Otitis media (OM, one of the most common pediatric infectious diseases, causes inner ear inflammation resulting in vertigo and sensorineural hearing loss. Previously, we showed that spiral ligament fibrocytes (SLFs recognize OM pathogens and up-regulate chemokines. Here, we aim to determine a key molecule derived from SLFs, contributing to OM-induced inner ear inflammation. Methods Live NTHI was injected into the murine middle ear through the tympanic membrane, and histological analysis was performed after harvesting the temporal bones. Migration assays were conducted using the conditioned medium of NTHI-exposed SLFs with and without inhibition of MCP-1/CCL2 and CCR2. qRT-PCR analysis was performed to demonstrate a compensatory up-regulation of alternative genes induced by the targeting of MCP-1/CCL2 or CCR2. Results Transtympanic inoculation of live NTHI developed serous and purulent labyrinthitis after clearance of OM. THP-1 cells actively migrated and invaded the extracellular matrix in response to the conditioned medium of NTHI-exposed SLFs. This migratory activity was markedly inhibited by the viral CC chemokine inhibitor and the deficiency of MCP-1/CCL2, indicating that MCP-1/CCL2 is a main attractant of THP-1 cells among the SLF-derived molecules. We further demonstrated that CCR2 deficiency inhibits migration of monocyte-like cells in response to NTHI-induced SLF-derived molecules. Immunolabeling showed an increase in MCP-1/CCL2 expression in the cochlear lateral wall of the NTHI-inoculated group. Contrary to the in vitro data, deficiency of MCP-1/CCL2 or CCR2 did not inhibit OM-induced inner ear inflammation in vivo. We demonstrated that targeting MCP-1/CCL2 enhances NTHI-induced up-regulation of MCP-2/CCL8 in SLFs and up-regulates the basal expression of CCR2 in the splenocytes. We also found that targeting CCR2 enhances NTHI-induced up-regulation of MCP-1/CCL2 in SLFs. Conclusions Taken together, we suggest that

  6. Pseudogenization of the MCP-2/CCL8 chemokine gene in European rabbit (genus Oryctolagus), but not in species of Cottontail rabbit (Sylvilagus) and Hare (Lepus)

    Science.gov (United States)

    2012-01-01

    Background Recent studies in human have highlighted the importance of the monocyte chemotactic proteins (MCP) in leukocyte trafficking and their effects in inflammatory processes, tumor progression, and HIV-1 infection. In European rabbit (Oryctolagus cuniculus) one of the prime MCP targets, the chemokine receptor CCR5 underwent a unique structural alteration. Until now, no homologue of MCP-2/CCL8a, MCP-3/CCL7 or MCP-4/CCL13 genes have been reported for this species. This is interesting, because at least the first two genes are expressed in most, if not all, mammals studied, and appear to be implicated in a variety of important chemokine ligand-receptor interactions. By assessing the Rabbit Whole Genome Sequence (WGS) data we have searched for orthologs of the mammalian genes of the MCP-Eotaxin cluster. Results We have localized the orthologs of these chemokine genes in the genome of European rabbit and compared them to those of leporid genera which do (i.e. Oryctolagus and Bunolagus) or do not share the CCR5 alteration with European rabbit (i.e. Lepus and Sylvilagus). Of the Rabbit orthologs of the CCL8, CCL7, and CCL13 genes only the last two were potentially functional, although showing some structural anomalies at the protein level. The ortholog of MCP-2/CCL8 appeared to be pseudogenized by deleterious nucleotide substitutions affecting exon1 and exon2. By analyzing both genomic and cDNA products, these studies were extended to wild specimens of four genera of the Leporidae family: Oryctolagus, Bunolagus, Lepus, and Sylvilagus. It appeared that the anomalies of the MCP-3/CCL7 and MCP-4/CCL13 proteins are shared among the different species of leporids. In contrast, whereas MCP-2/CCL8 was pseudogenized in every studied specimen of the Oryctolagus - Bunolagus lineage, this gene was intact in species of the Lepus - Sylvilagus lineage, and was, at least in Lepus, correctly transcribed. Conclusion The biological function of a gene was often revealed in situations of

  7. Pseudogenization of the MCP-2/CCL8 chemokine gene in European rabbit (genus Oryctolagus, but not in species of Cottontail rabbit (Sylvilagus and Hare (Lepus

    Directory of Open Access Journals (Sweden)

    van der Loo Wessel

    2012-08-01

    Full Text Available Abstract Background Recent studies in human have highlighted the importance of the monocyte chemotactic proteins (MCP in leukocyte trafficking and their effects in inflammatory processes, tumor progression, and HIV-1 infection. In European rabbit (Oryctolagus cuniculus one of the prime MCP targets, the chemokine receptor CCR5 underwent a unique structural alteration. Until now, no homologue of MCP-2/CCL8a, MCP-3/CCL7 or MCP-4/CCL13 genes have been reported for this species. This is interesting, because at least the first two genes are expressed in most, if not all, mammals studied, and appear to be implicated in a variety of important chemokine ligand-receptor interactions. By assessing the Rabbit Whole Genome Sequence (WGS data we have searched for orthologs of the mammalian genes of the MCP-Eotaxin cluster. Results We have localized the orthologs of these chemokine genes in the genome of European rabbit and compared them to those of leporid genera which do (i.e. Oryctolagus and Bunolagus or do not share the CCR5 alteration with European rabbit (i.e. Lepus and Sylvilagus. Of the Rabbit orthologs of the CCL8, CCL7, and CCL13 genes only the last two were potentially functional, although showing some structural anomalies at the protein level. The ortholog of MCP-2/CCL8 appeared to be pseudogenized by deleterious nucleotide substitutions affecting exon1 and exon2. By analyzing both genomic and cDNA products, these studies were extended to wild specimens of four genera of the Leporidae family: Oryctolagus, Bunolagus, Lepus, and Sylvilagus. It appeared that the anomalies of the MCP-3/CCL7 and MCP-4/CCL13 proteins are shared among the different species of leporids. In contrast, whereas MCP-2/CCL8 was pseudogenized in every studied specimen of the Oryctolagus - Bunolagus lineage, this gene was intact in species of the Lepus - Sylvilagus lineage, and was, at least in Lepus, correctly transcribed. Conclusion The biological function of a gene was often

  8. Analogue saturation limit of single and double 10 mm microchannel plate photomultiplier tubes

    Science.gov (United States)

    Milnes, J. S.; Conneely, T. M.; Horsfield, C. J.

    2016-11-01

    Photek are a well-established supplier of microchannel plate (MCP) photomultiplier tubes (PMTs) to the inertial confinement fusion community. The analogue signals produced at the major inertial confinement fusion facilities cover many orders of magnitude, therefore understanding the upper saturation limit of MCP-PMTs to large low rate signals takes on a high importance. Here we present a study of a single and a double MCP-PMT with 10 mm diameter active area. The saturation was studied for a range of optical pulse widths from 4 ns to 100 ns and at a range of electron gain values: 103 to 104 for the single and 104 to 106 for the double. We have shown that the saturation level of ˜1.2 nC depends only on the integrated charge of the pulse and is independent of pulse width and gain over this range, but that the level of charge available in deep saturation is proportional to the operating gain.

  9. Measuring position in 2-dimensions using induced signals in a microchannel plate detector

    Science.gov (United States)

    Wiggins, Blake; Desouza, Romualdo

    2017-01-01

    Position-sensitive microchannel plate (MCP) detectors play an important role in the detection of photons, electrons, ions, and neutrons. Recently, a novel approach has been developed to provide position-sensitivity for an MCP detector. In this approach, namely the induced signal approach, the position of the incident particle is determined by sensing the electron cloud emanating from a MCP stack. The induced signals are inherently bipolar, where the negative lobe of the induced signal corresponds to the approach of the electron cloud to the sense wires and the positive lobe corresponds to the recession of the electron cloud from the sense wires. The zero-crossing point is the time at which the centroid of the charge cloud passes the wire plane. For a single incident electron, a spatial resolution of 103 μm (FWHM) has been achieved by utilizing the zero-crossing point of the induced signals. General considerations suggest that this spatial resolution can be improved by using the entire pulse shape information. The fundamentals of the induced signal approach as well as its implementation in slow neutron radiography will be presented. Supported by the US DOE NNSA under Award No. DE-NA0002012.

  10. Reduced expression of collagen VI alpha 3 (COL6A3) confers resistance to inflammation-induced MCP1 expression in adipocytes.

    Science.gov (United States)

    Gesta, Stephane; Guntur, Kalyani; Majumdar, Ishita Deb; Akella, Syamala; Vishnudas, Vivek K; Sarangarajan, Rangaprasad; Narain, Niven R

    2016-08-01

    Collagen VI alpha 3 (COL6A3) is associated with insulin resistance and adipose tissue inflammation. In this study, the role of COL6A3 in human adipocyte function was characterized. Immortalized human preadipocyte cell lines stably expressing control or COL6A3 shRNA were used to study adipocyte function and inflammation. COL6A3 knockdown increased triglyceride content, lipolysis, insulin-induced Akt phosphorylation, and mRNA expression of key adipogenic genes (peroxisome proliferator-activated receptor-γ, glucose transporter, adiponectin, and fatty acid binding protein), indicating increased adipocyte function and insulin sensitivity. However, COL6A3 knockdown decreased basal adipocyte chemokine (C-C motif) ligand 2 [CCL2, monocyte chemoattractant protein (MCP1)] mRNA expression, reduced secreted protein levels, and abrogated tumor necrosis factor-α- and lipopolysaccharide-induced MCP1 mRNA expression. In addition, while control adipocytes co-cultured with THP1 macrophages showed a threefold increase in adipocyte MCP1 mRNA expression, in COL6A3 knockdown adipocytes MCP1 mRNA expression was unaltered by co-culturing. Lastly, in normal differentiated adipocytes, matrix metalloproteinase-11 treatment reduced expression of COL6A3 protein, MCP1 mRNA, MCP1 secretion, and abrogated tumor necrosis factor-α- and lipopolysaccharide-induced MCP1 mRNA expression and protein secretion. COL6A3 knockdown in adipocytes leads to the development of a unique state of inflammatory resistance via suppression of MCP1 induction. © 2016 The Obesity Society.

  11. Production of recombinant capsid protein of Macrobrachium rosenbergii nodavirus (r-MCP43) of giant freshwater prawn, M. rosenbergii (de Man) for immunological diagnostic methods.

    Science.gov (United States)

    Farook, M A; Madan, N; Taju, G; Majeed, S Abdul; Nambi, K S N; Raj, N Sundar; Vimal, S; Hameed, A S Sahul

    2014-08-01

    White tail disease (WTD) caused by Macrobrachium rosenbergii nodavirus (MrNV) and extra small virus (XSV) is a serious problem in prawn hatcheries. The gene for capsid protein of MrNV (MCP43) was cloned into pRSET B expression vector. The MCP43 protein was expressed as a protein with a 6-histidine tag in Escherichia coli GJ1158 with NaCl induction. This recombinant protein, which was used to raise the antiserum in rabbits, recognized capsid protein in different WTD-infected post-larvae and adult prawn. Various immunological methods such as Western blot, dot blot and ELISA techniques were employed to detect MrNV in infected samples using the antiserum raised against recombinant MCP43 of MrNV. The dot blot assay using anti-rMCP43 was found to be capable of detecting MrNV in WTD-infected post-larvae as early as at 24 h post-infection. The antiserum raised against r-MCP43 could detect the MrNV in the infected samples at the level of 100 pg of total protein. The capsid protein of MrNV estimated by ELISA using anti-rMCP43 and pure r-MCP43 as a standard was found to increase gradually during the course of infection from 24 h p.i. to moribund stage. The results of immunological diagnostic methods employed in this study were compared with that of RT-PCR to test the efficiency of antiserum raised against r-MCP43 for the detection of MrNV. The Western blot, dot blot and ELISA detected all MrNV-positive coded samples as detected by RT-PCR.

  12. Effect of Ethylene and 1-Methylcyclopropene (1-MCP) on color and Firmness of Red and Breaker Stage Tomato Stored at Different Temperatures

    OpenAIRE

    Tadesse, T.N.; Farneti, B.; Woltering, E.J.

    2012-01-01

    The red color of the tomato fruit during ripening is due to the presence lycopene, a compound known for its antioxidant property. This compound is influenced by temperature, ethylene and 1-Methylcyclopropene (1-MCP) treatment. It was believed that ethylene application at chilling temperature could help increase the amount of lycopene content of tomato fruits. In addition, application of 1-MCP was assumed to reduce the action of ethylene on production of lycopene content and decrease loss of f...

  13. Response of a chevron microchannel plate to 2.5 and 14 MeV neutrons

    Science.gov (United States)

    Medley, S. S.; Persing, R.

    1981-10-01

    The response of a large area (4.6×13 cm) multianode channel electron multiplier array (CEMA) detector to energetic neutrons was investigated. The measured neutron detection efficiencies of the chevron microchannel plate (MCP) were 1.7×10-3 and 6.4×10-3 counts/neutron, respectively, for 2.5 MeV-DD and 14 MeV-DT neutrons. The apparently higher efficiency observed for the 14 MeV neutrons is attributed to neutron-induced background gamma radiation.

  14. Effect of the Cooling System and 1-MCP on the Incidence of Superficial Scald in ‘Granny Smith’ Apples Efecto del Sistema de Enfriamiento y 1-MCP sobre la Incidencia de Escaldado Superficial en Manzanas ‘Granny Smith’

    Directory of Open Access Journals (Sweden)

    Claudia Moggia

    2009-09-01

    Full Text Available A study was carried out to determine the effects of two cooling systems and the application of 1-methylcyclopropene (1-MCP, SmartFreshTM on the incidence of superficial scald in apples (Malus domestica Borkh. cv. Granny Smith. Fruit were collected from a commercial orchard (Colbún, Maule Region, Chile during 2004-2005 season. A completely randomized design was used in a 2 x 2 factorial arrangement, using cooling systems (normal and step-wise cooling and application of 1-MCP (0 and 625 nL L-1 i.a. as the main factors. Fruit from normal cooling were kept at 0 °C throughout the storage period (180 days. Step-wise cooling consisted of storing the fruit at 10 °C for 10 days; 4 °C for the next 20 days and 0 °C for the remaining 150 days. Every month, maturity indices and the chemicals, global antioxidant content (AO, α-farnesene (AF and conjugated trienes (TC, were measured. Incidence of superficial scald was determined after 180 days of storage, plus 10 days at 20 °C . The application of 1-MCP with both cooling systems was capable of maintaining firmness values around 8,2 kg up to the end of the storage period, as well as decreasing the concentration of AF, TC and AO during storage. Incidence of superficial scald on fruit with 1-MCP was 0%, regardless of the type of cooling. Among treatments without 1-MCP, step-wise-cooling was more effective in preventing superficial scald, resulting in 1.3% incidence compared to 75.6% with the normal cooling system. Nevertheless, from the fourth month onwards firmness was lower than that required for export.Se desarrolló un estudio para determinar el efecto de dos sistemas de enfriamiento y la aplicación de 1-metilciclopropeno (1-MCP, SmartFreshTM sobre la incidencia de escaldado superficial en manzanas (Malus domestica Borkh. cv. Granny Smith, colectadas de un huerto comercial (Colbún, Región del Maule, Chile durante la temporada 2004-2005. El ensayo consistió en un diseño completamente al azar con

  15. Blue Willow Story Plates

    Science.gov (United States)

    Fontes, Kris

    2009-01-01

    In the December 1997 issue of "SchoolArts" is a lesson titled "Blue Willow Story Plates" by Susan Striker. In this article, the author shares how she used this lesson with her middle-school students many times over the years. Here, she describes a Blue Willow plate painting project that her students made.

  16. Create Your Plate

    Medline Plus

    Full Text Available ... In Memory In Honor Become a Member En Español Type 1 Type 2 About Us Online Community ... Page Text Size: A A A Listen En Español Create Your Plate Create Your Plate is a ...

  17. Create Your Plate

    Medline Plus

    Full Text Available ... Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal Planning ... Planning Meals Diabetes Meal Plans and a Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets ...

  18. Growth Factors: Production of Monocyte Chemotactic Protein-1 (MCP-1/JE) by Bone Marrow Stromal Cells: Effect on the Migration and Proliferation of Hematopoietic Progenitor Cells.

    Science.gov (United States)

    Xu, Y. X.; Talati, B. R.; Janakiraman, N.; Chapman, R. A.; Gautam, S. C.

    1999-01-01

    Recombinant chemotactic cytokines (chemokines) have been shown to modulate in vitro proliferation of hematopoietic progenitor cells. Whether bone marrow stromal cells produce chemokines and the physiological role they may have in the regulation of hematopoiesis has largely remained unexamined. We have examined the expression of monocyte chemoattractant protein-1 (MCP-1/JE) in bone marrow stromal cells and its effect on the migration and proliferation of murine hematopoietic progenitor cells. Freshly derived murine bone marrow stromal cells were found to secrete abundant amounts of MCP-1/JE, which was further increased upon stimulation of stromal cells with pro-inflammatory agents LPS, IL1-alpha, IFN-gamma, or TNF-alpha. Although culture supernatant conditioned by stromal cells exhibited chemotactic activity toward hematopoietic progenitor cells, the chemotactic activity was not due to MCP-1/JE. Furthermore, rMCP-1/JE also failed to induce migration of progenitor cells. MCP-1/JE, however, caused 20 to 30% increase in the clonal expansion of progenitor cells. Thus, although MCP-1/JE does not chemoattract hematopoietic progenitor cells it may have a role in their proliferation and clonal expansion.

  19. Distribution of monocyte chemoattractant protein-1 (MCP-1 A-2518G) and chemokine receptor (CCR2-V64Ι) gene variants in hyperbilirubinemic newborns.

    Science.gov (United States)

    Narter, Fatma; Bireller, Elif Sinem; Engin, Can; Catmakas, Tolga; Narter, Fehmi; Ergen, Arzu; Cakmakoglu, Bedia

    2015-01-01

    Hyperbilirubinemia is one of the most crucial syndromes, which is characterized by high levels of bilirubin, especially when it occurs in newborns. Bilirubin has cytoprotective properties with an antioxidant function and plays several major roles in the inflammation process with its members such as chemokines. The monocyte chemoattractant protein-1 (MCP-1) is a member of the C-C chemokine family and it has been associated with the inflammatory process. There are no data on the chemokine and its receptor genotypes in hyperbilirubinemic newborns to show their distribution. The aim of this study is to investigate the genotypic relationship of MCP-1 and its receptor CCR2-V64Ι with hyperbilirubinemia in Turkish newborns. A total of 85 newborns were included in the study: 20 infants with hyperbilirubinemia (hyperbilirubinemic group) and 65 infants without hyperbilirubinemia (non-hyperbilirubinemic group). Genotyping of MCP-1 A-2518G and CCR2-V64Ι gene polymorphisms were detected by PCR-RFLP, respectively. MCP-1 GG genotype in patients was higher than the controls and this genotype had 2.69 times higher risk for hyperbilirubinemic neonates (P: 0.20). The frequency of MCP-1 A-2518G G+ genotype in patients was higher than the controls (55.0% and 38.5%, respectively). The results of our preliminary study suggest that MCP-1 G+ genotype has the ability to increase the hyperbilirubinemia risk of newborns. These results should be focused on to research on a larger scale to confirm the findings.

  20. On Construction Technology of Plate-type Ballastless Track for 350km/h Railway Switch%时速350km铁路道岔板式无砟轨道施工工艺研究

    Institute of Scientific and Technical Information of China (English)

    李同海

    2012-01-01

    铁路道岔是列车安全运行必须通过的“咽喉”区,高速铁路道岔铺设的平顺性和总体施工质量,更是至关重要,决定着高速列车的平稳通过和安全运行。通过石武客运专线工程的施工实践,进一步探索和研究高速铁路道岔板式无砟轨道的施工工艺,使其不断完善和成熟,较好地实现道岔铺设的平顺性,保证工程总体质量,取得一定效果。%he railway switch is a "throat" for the running of trains. The smoothness and overall construction quality of the laying of high-speed railway switch guarantee the successful passing and safe running of high-speed trains. Through construction practice of Shijiazhuang-Wuhan passenger line project, this paper further explores, researches and improves the construction technology of plate-type ballastless track for high-speed railway switch, which better realizes the smoothness of switch laying, ensures the overall construction quality and achieves a certain effect.

  1. Technology

    Directory of Open Access Journals (Sweden)

    Xu Jing

    2016-01-01

    Full Text Available The traditional answer card reading method using OMR (Optical Mark Reader, most commonly, OMR special card special use, less versatile, high cost, aiming at the existing problems proposed a method based on pattern recognition of the answer card identification method. Using the method based on Line Segment Detector to detect the tilt of the image, the existence of tilt image rotation correction, and eventually achieve positioning and detection of answers to the answer sheet .Pattern recognition technology for automatic reading, high accuracy, detect faster

  2. Pixelated neutron image plates

    Science.gov (United States)

    Schlapp, M.; Conrad, H.; von Seggern, H.

    2004-09-01

    Neutron image plates (NIPs) have found widespread application as neutron detectors for single-crystal and powder diffraction, small-angle scattering and tomography. After neutron exposure, the image plate can be read out by scanning with a laser. Commercially available NIPs consist of a powder mixture of BaFBr : Eu2+ and Gd2O3 dispersed in a polymer matrix and supported by a flexible polymer sheet. Since BaFBr : Eu2+ is an excellent x-ray storage phosphor, these NIPs are particularly sensitive to ggr-radiation, which is always present as a background radiation in neutron experiments. In this work we present results on NIPs consisting of KCl : Eu2+ and LiF that were fabricated into ceramic image plates in which the alkali halides act as a self-supporting matrix without the necessity for using a polymeric binder. An advantage of this type of NIP is the significantly reduced ggr-sensitivity. However, the much lower neutron absorption cross section of LiF compared with Gd2O3 demands a thicker image plate for obtaining comparable neutron absorption. The greater thickness of the NIP inevitably leads to a loss in spatial resolution of the image plate. However, this reduction in resolution can be restricted by a novel image plate concept in which a ceramic structure with square cells (referred to as a 'honeycomb') is embedded in the NIP, resulting in a pixelated image plate. In such a NIP the read-out light is confined to the particular illuminated pixel, decoupling the spatial resolution from the optical properties of the image plate material and morphology. In this work, a comparison of experimentally determined and simulated spatial resolutions of pixelated and unstructured image plates for a fixed read-out laser intensity is presented, as well as simulations of the properties of these NIPs at higher laser powers.

  3. Plate removal following orthognathic surgery.

    Science.gov (United States)

    Little, Mhairi; Langford, Richard Julian; Bhanji, Adam; Farr, David

    2015-11-01

    The objectives of this study are to determine the removal rates of orthognathic plates used during orthognathic surgery at James Cook University Hospital and describe the reasons for plate removal. 202 consecutive orthognathic cases were identified between July 2004 and July 2012. Demographics and procedure details were collected for these patients. Patients from this group who returned to theatre for plate removal between July 2004 and November 2012 were identified and their notes were analysed for data including reason for plate removal, age, smoking status, sex and time to plate removal. 3.2% of plates were removed with proportionally more plates removed from the mandible than the maxilla. 10.4% of patients required removal of one or more plate. Most plates were removed within the first post-operative year. The commonest reasons for plate removal were plate exposure and infection. The plate removal rates in our study are comparable to those seen in the literature.

  4. Plating in Top Agar

    OpenAIRE

    sprotocols

    2014-01-01

    1. Warm plates to room temperature before use. Cold plates causes the top agar to solidify irregularly. DO not warm plates to 37° as the top agar will take forever to solidify. - Prepare top agar as the appropriate liquid medium with 0.7% agar. Keeping 100 mL bottles is convenient. For phages, use λ top agar, which is less rich and yields bigger plaques. - Melt top agar in the microwave completely. Allow the agar to boil after liquification; incompletely melted agar looks liquid, but is...

  5. The Effect of Post-Resistance Exercise Amino Acids on Plasma MCP-1 and CCR2 Expression

    Directory of Open Access Journals (Sweden)

    Adam J. Wells

    2016-07-01

    Full Text Available The recruitment and infiltration of classical monocytes into damaged muscle is critical for optimal tissue remodeling. This study examined the effects of an amino acid supplement on classical monocyte recruitment following an acute bout of lower body resistance exercise. Ten resistance-trained men (24.7 ± 3.4 years; 90.1 ± 11.3 kg; 176.0 ± 4.9 cm ingested supplement (SUPP or placebo (PL immediately post-exercise in a randomized, cross-over design. Blood samples were obtained at baseline (BL, immediately (IP, 30-min (30P, 1-h (1H, 2-h (2H, and 5-h (5H post-exercise to assess plasma concentrations of monocyte chemoattractant protein 1 (MCP-1, myoglobin, cortisol and insulin concentrations; and expressions of C-C chemokine receptor-2 (CCR2, and macrophage-1 antigen (CD11b on classical monocytes. Magnitude-based inferences were used to provide inferences on the true effects of SUPP compared to PL. Changes in myoglobin, cortisol, and insulin concentrations were similar between treatments. Compared to PL, plasma MCP-1 was “very likely greater” (98.1% likelihood effect in SUPP at 2H. CCR2 expression was “likely greater” at IP (84.9% likelihood effect, “likely greater” at 1H (87.7% likelihood effect, “very likely greater” at 2H (97.0% likelihood effect, and “likely greater” at 5H (90.1% likelihood effect in SUPP, compared to PL. Ingestion of SUPP did not influence CD11b expression. Ingestion of an amino acid supplement immediately post-exercise appears to help maintain plasma MCP-1 concentrations and augment CCR2 expression in resistance trained men.

  6. Aumento da expressão do MCP-1 coroidal e escleral em modelo experimental de hipercolesterolemia

    OpenAIRE

    Rogil José de Almeida Torres; Lucia Noronha; Antonio Marcelo Barbante Casella; Thaís Isabel Lumikoski; Leonardo Brandão Précoma; Caroline Luzia de Almeida Torres; Andréa Luchini; Mario Claudio Soares Sturzeneker; Dalton Bertolim Précoma

    2012-01-01

    OBJETIVO: O objetivo deste trabalho é demonstrar experimentalmente que a dieta rica em colesterol provoca aumento da expressão da MCP-1 na coroide e esclera. MÉTODO: Coelhos New Zealand foram organizados em dois grupos: GN (grupo dieta normal), composto por 8 coelhos (8 olhos), recebeu ração padrão para coelhos, durante 4 semanas; GH (grupo hipercolesterolêmico), composto por 13 coelhos (13 olhos), recebeu dieta rica em colesterol a 1% por 8 semanas. Foi realizada a dosagem sérica de colester...

  7. Congruency of scapula locking plates: implications for implant design.

    Science.gov (United States)

    Park, Andrew Y; DiStefano, James G; Nguyen, Thuc-Quyen; Buckley, Jenni M; Montgomery, William H; Grimsrud, Chris D

    2012-04-01

    We conducted a study to evaluate the congruency of fit of current scapular plate designs. Three-dimensional image-processing and -analysis software, and computed tomography scans of 12 cadaveric scapulae were used to generate 3 measurements: mean distance from plate to bone, maximum distance, and percentage of plate surface within 2 mm of bone. These measurements were used to quantify congruency. The scapular spine plate had the most congruent fit in all 3 measured variables. The lateral border and glenoid plates performed statistically as well as the scapular spine plate in at least 1 of the measured variables. The medial border plate had the least optimal measurements in all 3 variables. With locking-plate technology used in a wide variety of anatomical locations, the locking scapula plate system can allow for a fixed-angle construct in this region. Our study results showed that the scapular spine, glenoid, and lateral border plates are adequate in terms of congruency. However, design improvements may be necessary for the medial border plate. In addition, we describe a novel method for quantifying hardware congruency, a method that can be applied to any anatomical location.

  8. Create Your Plate

    Medline Plus

    Full Text Available ... blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ... but changes the portion sizes so you are getting larger portions of non-starchy vegetables and a ...

  9. Create Your Plate

    Medline Plus

    Full Text Available ... blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ... 4/Box) Taking the guesswork out of portion control has never been easier. It can be a ...

  10. Tectonic Plate Movement.

    Science.gov (United States)

    Landalf, Helen

    1998-01-01

    Presents an activity that employs movement to enable students to understand concepts related to plate tectonics. Argues that movement brings topics to life in a concrete way and helps children retain knowledge. (DDR)

  11. MyPlate

    Science.gov (United States)

    ... our stage of life, situations, preferences, access to food, culture, traditions, and the personal decisions we make over time. All your food and beverage choices count. MyPlate offers ideas and ...

  12. Create Your Plate

    Medline Plus

    Full Text Available ... blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ... you have an easy portion control solution that works. Last Reviewed: October 8, 2015 Last Edited: September ...

  13. Designing Assemblies Of Plates

    Science.gov (United States)

    Williams, F. W.; Kennedy, D.; Butler, R.; Aston, G.; Anderson, M. S.

    1992-01-01

    VICONOPT calculates vibrations and instabilities of assemblies of prismatic plates. Designed for efficient, accurate analysis of buckling and vibration, and for optimum design of panels of composite materials. Written in FORTRAN 77.

  14. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal Planning What Can I Eat? Making Healthy Food Choices Diabetes Superfoods Non-starchy Vegetables Grains and Starchy Vegetables ...

  15. Create Your Plate

    Medline Plus

    Full Text Available ... Recipes Association Cookbook Recipes Planning Meals Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning ... serving of dairy or both as your meal plan allows. Choose healthy fats in small amounts. For ...

  16. Create Your Plate

    Medline Plus

    Full Text Available ... 1 Diabetes Get Started Safely Get And Stay Fit Types of Activity Weight Loss Assess Your Lifestyle ... manage portion control wherever you are. Now, our best-selling, sectioned to-go plate with easy-sealing ...

  17. Create Your Plate

    Medline Plus

    Full Text Available ... Plate is a simple and effective way to manage your blood glucose levels and lose weight. With ... been easier. It can be a challenge to manage portion control wherever you are. Now, our best- ...

  18. Tectonic Plate Movement.

    Science.gov (United States)

    Landalf, Helen

    1998-01-01

    Presents an activity that employs movement to enable students to understand concepts related to plate tectonics. Argues that movement brings topics to life in a concrete way and helps children retain knowledge. (DDR)

  19. Create Your Plate

    Medline Plus

    Full Text Available ... Carbohydrates Carbohydrate Counting Make Your Carbs Count Glycemic ... to manage portion control wherever you are. Now, our best-selling, sectioned to-go plate with easy-sealing ...

  20. Increased Eotaxin and MCP-1 Levels in Serum from Individuals with Periodontitis and in Human Gingival Fibroblasts Exposed to Pro-Inflammatory Cytokines

    Science.gov (United States)

    Sulniute, Rima; Palmqvist, Py; Majster, Mirjam; Holm, Cecilia Koskinen; Zwicker, Stephanie; Clark, Reuben; Önell, Sebastian; Johansson, Ingegerd; Lerner, Ulf H.; Lundberg, Pernilla

    2015-01-01

    Periodontitis is a chronic inflammatory disease of tooth supporting tissues resulting in periodontal tissue destruction, which may ultimately lead to tooth loss. The disease is characterized by continuous leukocyte infiltration, likely mediated by local chemokine production but the pathogenic mechanisms are not fully elucidated. There are no reliable serologic biomarkers for the diagnosis of periodontitis, which is today based solely on the degree of local tissue destruction, and there is no available biological treatment tool. Prompted by the increasing interest in periodontitis and systemic inflammatory mediators we mapped serum cytokine and chemokine levels from periodontitis subjects and healthy controls. We used multivariate partial least squares (PLS) modeling and identified monocyte chemoattractant protein-1 (MCP-1) and eotaxin as clearly associated with periodontitis along with C-reactive protein (CRP), years of smoking and age, whereas the number of remaining teeth was associated with being healthy. Moreover, body mass index correlated significantly with serum MCP-1 and CRP, but not with eotaxin. We detected higher MCP-1 protein levels in inflamed gingival connective tissue compared to healthy but the eotaxin levels were undetectable. Primary human gingival fibroblasts displayed strongly increased expression of MCP-1 and eotaxin mRNA and protein when challenged with tumor necrosis factor-α (TNF-α and interleukin-1β (IL-1β), key mediators of periodontal inflammation. We also demonstrated that the upregulated chemokine expression was dependent on the NF-κΒ pathway. In summary, we identify higher levels of CRP, eotaxin and MCP-1 in serum of periodontitis patients. This, together with our finding that both CRP and MCP-1 correlates with BMI points towards an increased systemic inflammatory load in patients with periodontitis and high BMI. Targeting eotaxin and MCP-1 in periodontitis may result in reduced leukocyte infiltration and inflammation in

  1. Inhibitory effect of microRNA-27b on interleukin 17 (IL-17)-induced monocyte chemoattractant protein-1 (MCP1) expression.

    Science.gov (United States)

    Huang, K D; Shen, Y; Wei, X; Zhang, F Q; Liu, Y Y; Ma, L

    2016-07-14

    We investigated the effect of microRNA-27b (miR-27b), a gene expression regulatory factor, on the expression of monocyte chemoattractant protein-1 (MCP1) stimulated by interleukin 17 (IL-17). After IL-17 had been added to H9C2 cardiomyocytes, an miR-27b mimic was transfected into the H9C2 cells. The mRNA expression levels of miR-27b and MCP1 in the H9C2 cells were detected by SYBR green I fluorescence quantitative reverse transcription polymerase chain reaction. Enzyme-linked immunosorbent assay was used to measure the expression levels of MCP1 protein in the H9C2 cells. The expression of MCP1 mRNA in the H9C2 cells began to increase 2 h after IL-17 stimulation, reached a peak at 4 h, and then decreased. The MCP1 protein level increased gradually in the 24 h following IL-17 stimulation. After transfection with the miR-27b mimic, the expression of miR-27b in the H9C2 cells significantly increased than that in the miRNA negative control group (P < 0.01). The MCP1 mRNA and protein levels in the miR-27b mimic + IL-17 group were significantly reduced than that in the miRNA negative control + IL-17 group (P < 0.01). miR-27b inhibited IL-17-induced MCP1 expression in the H9C2 cells, which demonstrates that treatment with microRNA could alleviate myocardial injury in viral myocarditis.

  2. Increased Eotaxin and MCP-1 Levels in Serum from Individuals with Periodontitis and in Human Gingival Fibroblasts Exposed to Pro-Inflammatory Cytokines.

    Science.gov (United States)

    Boström, Elisabeth A; Kindstedt, Elin; Sulniute, Rima; Palmqvist, Py; Majster, Mirjam; Holm, Cecilia Koskinen; Zwicker, Stephanie; Clark, Reuben; Önell, Sebastian; Johansson, Ingegerd; Lerner, Ulf H; Lundberg, Pernilla

    2015-01-01

    Periodontitis is a chronic inflammatory disease of tooth supporting tissues resulting in periodontal tissue destruction, which may ultimately lead to tooth loss. The disease is characterized by continuous leukocyte infiltration, likely mediated by local chemokine production but the pathogenic mechanisms are not fully elucidated. There are no reliable serologic biomarkers for the diagnosis of periodontitis, which is today based solely on the degree of local tissue destruction, and there is no available biological treatment tool. Prompted by the increasing interest in periodontitis and systemic inflammatory mediators we mapped serum cytokine and chemokine levels from periodontitis subjects and healthy controls. We used multivariate partial least squares (PLS) modeling and identified monocyte chemoattractant protein-1 (MCP-1) and eotaxin as clearly associated with periodontitis along with C-reactive protein (CRP), years of smoking and age, whereas the number of remaining teeth was associated with being healthy. Moreover, body mass index correlated significantly with serum MCP-1 and CRP, but not with eotaxin. We detected higher MCP-1 protein levels in inflamed gingival connective tissue compared to healthy but the eotaxin levels were undetectable. Primary human gingival fibroblasts displayed strongly increased expression of MCP-1 and eotaxin mRNA and protein when challenged with tumor necrosis factor-α (TNF-α and interleukin-1β (IL-1β), key mediators of periodontal inflammation. We also demonstrated that the upregulated chemokine expression was dependent on the NF-κΒ pathway. In summary, we identify higher levels of CRP, eotaxin and MCP-1 in serum of periodontitis patients. This, together with our finding that both CRP and MCP-1 correlates with BMI points towards an increased systemic inflammatory load in patients with periodontitis and high BMI. Targeting eotaxin and MCP-1 in periodontitis may result in reduced leukocyte infiltration and inflammation in

  3. 经皮接骨板固定技术结合锁定钢板治疗胫腓骨干骨折疗效观察%Clinical Observation of Using Minimally Invasive Percutaneous Plate Osteosynthesis Technology Combined with Locking Compression Plate in Treating Tibia and Fibula Fracture

    Institute of Scientific and Technical Information of China (English)

    付建; 顾华; 张波涛

    2012-01-01

    Objective To evaluate the clinical efficacy of using minimally invasive percutaneous plate osteosynthesis (MIPPO) technology and locking compression plate (LCP) fixation in treating tibia and fibula fracture. Methods From November 2009 to January 2012, MIPPO technology combined with LCP fixation was used to treat tibia and fibula fractures in 62 patients. There were 42 males and 20 females. Their age ranged from 16 to 85 years old with an average of 45 years. According to AO classification, there were 10 cases of type A1, 3 of type A2, 3 of type A3, 18 of type B1, 8 of type B2, 4 of type B3, 10 of type Cl, 5 of type C2, and 1 of type C3. Among the patients, there were 47 cases of closed fractures and 15 of open fractures. According to Gustilo-Anderson classification, there were 8 cases of type I , 6 of type II , and 1 of type III , open fractures. Internal fixation operation was completed in 3 hours to 10 days after the injuries and the average time was 6 days. Results Among the open fracture patients, 3 got secondary curing, 1 had necrosis on the wound skin edge, 1 got cured after dressing and debridement of the exposed plate, 1 was cured after flap transfer onto the exposed bone, and all other patients got primary healing. All the 62 patients were followed up for 6 to 16 months, and the mean time was 9 months. No infection, nerve injury, or compartment syndrome occurred and all fractures were healed 2 to 4 months after operation. According to Johner-Wruhs clinical evaluation system, the condition was excellent in 48 patients, and good in 14. Among the 15 open fracture patients, the condition was excellent in 10, and good in 5. Conclusion MIPPO technology combined with LCP fixation for tibia and fibula fractures is an effective treatment with the advantages of fewer traumas, fast fracture healing and so on.%目的 探讨应用经皮接骨板固定技术(MIPPO)结合锁定钢板(LCP)固定治疗胫腓骨骨折的疗效.方法 2009年11月-2012年1月应用MIPPO技

  4. Origami - Folded Plate Structures

    OpenAIRE

    Buri, Hans Ulrich

    2010-01-01

    This research investigates new methods of designing folded plate structures that can be built with cross-laminated timber panels. Folded plate structures are attractive to both architects and engineers for their structural, spatial, and plastic qualities. Thin surfaces can be stiffened by a series of folds, and thus not only cover space, but also act as load bearing elements. The variation of light and shadow along the folded faces emphasizes the plas...

  5. Fractal multifiber microchannel plates

    Science.gov (United States)

    Cook, Lee M.; Feller, W. B.; Kenter, Almus T.; Chappell, Jon H.

    1992-01-01

    The construction and performance of microchannel plates (MCPs) made using fractal tiling mehtods are reviewed. MCPs with 40 mm active areas having near-perfect channel ordering were produced. These plates demonstrated electrical performance characteristics equivalent to conventionally constructed MCPs. These apparently are the first MCPs which have a sufficiently high degree of order to permit single channel addressability. Potential applications for these devices and the prospects for further development are discussed.

  6. Tests of Microchannel Plate (MCP) Detector Response to MeV Electrons in Support of Juno, JUICE, and Europa Mission UVS Instrument Investigations

    Science.gov (United States)

    Retherford, K. D.; Davis, M. W.; Greathouse, T. K.; Monreal, R. M.; Blase, R. C.; Raut, U.; Steffl, A. J.; Cooke, C. M.; Siegmun, O.; Gladstone, G. R.

    2016-10-01

    We report our efforts to optimize our UV Spectrograph (UVS) instruments for operating in the intense radiation environment of Jupiter for studying the ocean worlds of Europa and Ganymede in order to share our lessons learned.

  7. 1- MCP 处理对鸡蛋果常温贮藏效果的影响%Effects of 1 - MCP Treatment on Qualities of Passion Fruit at Ambient Temperature

    Institute of Scientific and Technical Information of China (English)

    姜翠翠; 李颖; 邱松山; 刘杰凤

    2016-01-01

    为延长鸡蛋果常温贮藏期品质,维持其较好的营养价值,分别采用0.50μL/L 和1.0μL/L 的1-甲基环丙烯(1-MCP)结合 PE 袋对鸡蛋果进行了保鲜处理,分析了鸡蛋果货架期间失重率,感官品质,可溶性固形物、维生素 C 的质量分数,质构特性等指标,并研究了其常温贮藏条件下的果实保鲜效果。结果表明:采用1.0μL/L 的1-MCP 结合 PE 袋处理过的果实在货架末期的失重率为0.39%,感官品质明显优于对照组,样品可溶性固形物质量分数维持在7.00%,维生素 C 的质量分数为28 mg/100 g ,硬度及黏度分别为800 g 和90 g/s ,均显著高于对照组果实。综合比较,1.0μL/L 1-MCP 结合 PE 袋处理能有效延缓果实的后熟衰老,确保货架期鸡蛋果果实品质。%In this paper we explore the effects of 1 - methylcyclopropene (1 -MCP) together with PE film treatment on passion fruit at room temperature ,and analyze the changes of weight loss rate ,soluble solids ,the content of vitamin C and its texture characteristic changes of samples during shelf life .Results show that after the treatment of 1 .0 μL/L 1 -MCP combined with PE film ,the weightlessness rate of sam-ple is 0 .39% ,soluble solids content is 7 .00 % ,the content of Vc is 28 mg/100 g ,the hardness and viscosity are respectively 800 g and 90 g/s ,and the quality of fruits in the end of shelf life is significantly higher than that of control group .Therefore 1 .0 μL/L 1 -MCP together with PE film treatment can effectively inhibit fruit metabolism ,regulate these physiological changes related to the aging process ,and play a better role in preservation .

  8. Vibration and Buckling of Web Plate of the Plate Girder

    OpenAIRE

    高橋, 和雄; 呉, 明強; 中澤, 聡志; 筑紫, 宏之

    1998-01-01

    The vibration and buckling of the web of the plate girder are studied in this paper. The small deflection theory of the thin plate is used. The finite strip method is employed to solve vibration and buckling of the plate girder. Natural frequenies of buckling properties are shown for various plate girder bridges.

  9. EFECTO DEL EMPAQUE Y DEL 1-MCP SOBRE CARACTERÍSTICAS FÍSICAS, QUÍMICAS Y FISIOLÓGICAS DE PITAHAYA AMARILLA EFEITO DA EMBALAGEM E DO 1-MCP SOB AS PROPRIEDADES QUÍMICAS, FÍSICAS E FISIOLÓGICAS DA PITAHAYA AMARELA EFFECT OF PACKAGING AND 1-MCP ON PHYSICAL, CHEMICAL AND PHYSIOLOGICAL CHARACTERISTICS OF PITAHAYA YELLOW

    Directory of Open Access Journals (Sweden)

    LILIANA SERNA C

    2011-12-01

    Full Text Available En pitahaya amarilla entera con grado de madurez 3, se evaluó el efecto del empaque (canastillas plásticas y cajas de cartón tipo exportación y la aplicación de soluciones acuosas de 1-Metilciclopropeno (200 y 400 µgL-1, sobre la pérdida de peso, firmeza, color, sólidos solubles, acidez titulable, tasa respiratoria y tiempo de vida comercial. Se encontró que en los dos empaques, la aplicación de soluciones acuosas de 200 y 400 µgL-1 de 1-Metilciclopropeno (1-MCP disminuyó los cambios en acidez, tasa respiratoria y color, sin embargo, aumentó la pérdida de peso durante el almacenamiento. El tipo de empaque afectó significativamente la pérdida de peso, los sólidos solubles y el color. La aplicación de 200 µgL-1 de 1-MCP generó menor variación en la luminosidad y en la coloración verde-amarilla en la fruta. Concentraciones de 200 y 400 µgL-1 de 1-MCP y el empaque en canastillas plásticas para mercado local permitieron prolongar el tiempo de vida comercial de la pitahaya amarilla 3 días. Los resultados de este estudio confirman además que la pitahaya amarilla es una fruta climatérica.Na pitahaya amarela inteira com grau tres de madures, foi avallado os efeitos da embalagem (cestos de plástico e caixas de papelão tipo exportação e a aplicação de soluções aquosas de 1-metilciclopropeno (200 e 400 µgL-1 sobre a perda de peso, firmeza, cor, teor de sólidos solúveis totais, acidez, taxa de respiração e tempo de vida comercial. Foi observado que nas duas embalagens, a aplicação de soluções aquosas de 200 e 400 µgL-1 de 1-Metilciclopropeno (1-MCP reduziu as variações na acidez, taxa de respiração e cor, no entanto, aumentou a perda de peso durante o armazenamento. 0 tipo da embalagem afetou significativamente a perda de peso, o teor de sólidos solúveis totais, e acor. A aplicação de 200 µgL-1 de 1-MCP gerou menor variação na luminosidade e na cor verde-amarela no fruto. Concentrações de 200 e 400

  10. Muscle glycogen depletion following 75-km of cycling is not linked to increased muscle IL-6, IL-8, and MCP-1 mRNA expression and protein content

    Directory of Open Access Journals (Sweden)

    David Christopher Nieman

    2016-09-01

    Full Text Available The cytokine response to heavy exertion varies widely for unknown reasons, and this study evaluated the relative importance of glycogen depletion, muscle damage, and stress hormone changes on blood and muscle cytokine measures. Cyclists (N=20 participated in a 75-km cycling time trial (168±26.0 min, with blood and vastus lateralis muscle samples collected before and after. Muscle glycogen decreased 77.2±17.4%, muscle IL-6, IL-8, and MCP-1 mRNA increased 18.5±2.8-, 45.3±7.8-, and 8.25±1.75-fold, and muscle IL-6, IL-8, and MCP-1 protein increased 70.5±14.1%, 347±68.1%, and 148±21.3%, respectively (all, P<0.001. Serum myoglobin and cortisol increased 32.1±3.3 to 242±48.3 mg/mL, and 295±27.6 to 784±63.5 nmol/L, respectively (both P<0.001. Plasma IL-6, IL-8, and MCP-1 increased 0.42±0.07 to 18.5±3.8, 4.07±0.37 to 17.0±1.8, and 96.5±3.7 to 240±21.6 pg/mL, respectively (all P<0.001. Increases in muscle IL-6, IL-8, and MCP-1 mRNA were unrelated to any of the outcome measures. Muscle glycogen depletion was related to change in plasma IL-6 (r=0.462, P=0.040, with change in myoglobin related to plasma IL-8 (r=0.582, P=0.007 and plasma MCP-1 (r=0.457, P=0.043, and muscle MCP-1 protein (r=0.588, P=0.017; cortisol was related to plasma IL-8 (r=0.613, P=0.004, muscle IL-8 protein (r=0.681, P=0.004, and plasma MCP-1 (r=0.442, P=0.050. In summary, this study showed that muscle IL-6, IL-8, and MCP-1 mRNA expression after 75-km cycling was unrelated to glycogen depletion and muscle damage, with change in muscle glycogen related to plasma IL-6, and changes in serum myoglobin and cortisol related to the chemotactic cytokines IL-8 and MCP-1.

  11. Tissue factor pathway inhibitor gene transfer prevents vascular smooth muscle cell proliferation by interfering with the MCP-3/CCR2 pathway.

    Science.gov (United States)

    Fu, Yu; Ma, Dandan; Liu, Yue; Li, Hui; Chi, Jinyu; Liu, Wenxiu; Lin, Fang; Hu, Jing; Zhang, Xiaohui; Zhu, Minling; Zhao, Yong; Yin, Xinhua

    2015-11-01

    Increased vascular smooth muscle cell (VSMC) proliferation substantially contributes to the pathogenesis of atherosclerosis and intimal hyperplasia after vascular injury. The importance of inflammation in VSMC proliferation is now being recognized. Preventing the inflammatory response is one therapeutic strategy that can be used to inhibit atherosclerosis in the clinic. The present study, using RNA interference and gene transfer techniques, was conducted to investigate the effect of monocyte chemotactic protein-3 (MCP-3) on VSMC proliferation that is a result of TNF-α stimulation, and whether overexpression of the tissue factor pathway inhibitor (TFPI) gene could prevent VSMC proliferation by blocking the MCP-3/CC chemokine receptor 2 (CCR2) pathway. Mouse VSMCs were infected in vitro with recombinant adenoviruses containing either mouse MCP-3-shRNA (Ad-MCP-3-shRNA), the TFPI gene (Ad-TFPI), or the negative control, which was shRNA encoding the sequence for EGFP (Ad-EGFP) or DMEM only. The cells were then stimulated with TNF-α for different time periods on the third day after gene transfer. The data show that VSMC proliferation in the Ad-MCP-3-shRNA and Ad-TFPI groups was markedly decreased using BrdU ELISA and MTT assays; MCP-3-shRNA and TFPI inhibited the expression of MCP-3 and CCR2 after long-term stimulation and inhibited the phosphorylation of ERK1/2 and AKT after short-term stimulation, as shown by ELISA and western blot analysis. This study provides convincing evidence that clarifies the effect of the proinflammatory factor MCP-3 in promoting VSMC proliferation. Our data also show, for the first time, that TFPI has an anti-proliferative role in TNF-α stimulated-VSMCs at least partly by interfering with the MCP-3/CCR2 pathway and then via suppression of the ERK1/2 and PI3K/AKT signaling pathways. We conclude that TFPI gene transfer may be a safe and effective therapeutic tool for treating atherosclerosis and intimal hyperplasia.

  12. PC-based car license plate reader

    Science.gov (United States)

    Hwang, Chung-Mu; Shu, Shyh-Yeong; Chen, Wen-Yu; Chen, Yie-Wern; Wen, Kuang-Pu

    1992-11-01

    A car license plate reader (CLPR) using fuzzy inference and neural network algorithm has been developed in Industrial Technology Research Institute (ITRI) and installed in highway toll stations to identify stolen cars. It takes an average of 0.7 seconds to recognize a car license plate by using a PC with 80486-50 CPU. The recognition rate of the system is about 97%. The techniques of CLPR include vehicle sensing, image grab control, optic pre- processing, lighting, and optic character recognition (OCR). The CLPR can be used in vehicle flow statistics, the checking of stolen vehicles, automatic charging systems in parking lots or garage management, and so on.

  13. Prokaryotic expression and in vitro functional analysis of IL-1β and MCP-1 from guinea pig.

    Science.gov (United States)

    Dirisala, Vijaya R; Jeevan, Amminikutty; Ly, Lan H; McMurray, David N

    2013-06-01

    The Guinea pig (Cavia porcellus) is an excellent animal model for studying human tuberculosis (TB) and also for a number of other infectious and non-infectious diseases. One of the major roadblocks in effective utilization of this animal model is the lack of readily available immunological reagents. In order to address this issue, guinea pig interleukin 1 beta (IL-1β) and monocyte chemoattractant protein-1 (MCP-1) were efficiently cloned and expressed in a prokaryotic expression vector, and the expressed proteins in soluble form from both the genes were confirmed by N-terminal sequencing. The biological activity of recombinant guinea pig IL-1β was demonstrated by its ability to drive proliferation in thymocytes, and the recombinant guinea pig MCP-1 exhibited chemotactic activity for guinea pig resident peritoneal macrophages. These biologically active recombinant guinea pig proteins will facilitate an in-depth understanding of the role they play in the immune responses of the guinea pig to TB and other diseases.

  14. PEG-albumin plasma expansion increases expression of MCP-1 evidencing increased circulatory wall shear stress: an experimental study.

    Directory of Open Access Journals (Sweden)

    C Makena Hightower

    Full Text Available Treatment of blood loss with plasma expanders lowers blood viscosity, increasing cardiac output. However, increased flow velocity by conventional plasma expanders does not compensate for decreased viscosity in maintaining vessel wall shear stress (WSS, decreasing endothelial nitric oxide (NO production. A new type of plasma expander using polyethylene glycol conjugate albumin (PEG-Alb causes supra-perfusion when used in extreme hemodilution and is effective in treating hemorrhagic shock, although it is minimally viscogenic. An acute 40% hemodilution/exchange-transfusion protocol was used to compare 4% PEG-Alb to Ringer's lactate, Dextran 70 kDa and 6% Hetastarch (670 kDa in unanesthetized CD-1 mice. Serum cytokine analysis showed that PEG-Alb elevates monocyte chemotactic protein-1 (MCP-1, a member of a small inducible gene family, as well as expression of MIP-1α, and MIP-2. MCP-1 is specific to increased WSS. Given the direct link between increased WSS and production of NO, the beneficial resuscitation effects due to PEG-Alb plasma expansion appear to be due to increased WSS through increased perfusion and blood flow rather than blood viscosity.

  15. The inhibitory effect of Gynostemma pentaphyllum on MCP-1 and type I procollagen expression in rat hepatic stellate cells.

    Science.gov (United States)

    Chen, Ming-Ho; Wang, Qwa-Fun; Chen, Lih-Geeng; Shee, Jia-Jen; Chen, Jung-Chou; Chen, Ke-Yu; Chen, Shu-Hsin; Su, Jyan-Gwo J; Liu, Yi-Wen

    2009-10-29

    Gynostemma pentaphyllum is a popular folk medicine that has been used for treatment of hepatitis in Asia. Our previous study demonstrates that Gynostemma pentaphyllum n-butanol extract inhibits the onset and improves the recovery of CCl(4)-induced liver fibrogenesis in rats and inhibits PDGF-induced rat hepatic stellate cells (HSCs) proliferation. In this study, the effect of Gynostemma pentaphyllum extract on cytokines and type I procollagen expression was analyzed. Rat HSCs were treated with PDGF, Gynostemma pentaphyllum n-butanol extract, RP-18-Gyp fraction, rapamycin or vehicle. Rat cytokine antibody array chip or ELISA kit was used for cytokines detection. Intracellular protein expression was detected by Western blotting, mRNA expression was analyzed by RT-PCR. RP-18-Gyp fraction is the more purified gypenosides fraction from Gynostemma pentaphyllum n-butanol extract. In cell proliferation, the inhibitory effect of 200 microg/ml RP-18-Gyp fraction is similar to 500 microg/ml Gynostemma pentaphyllum n-butanol extract. Furthermore, both of them have the ability of decreasing monocyte chemoattractant protein-1 (MCP-1) mRNA expression and protein release and inhibiting type I procollagen protein expression. Both of Gynostemma pentaphyllum n-butanol extract and its more purified RP-18-Gyp fraction have the biological activities in the inhibition of cell proliferation, MCP-1 release and type I procollagen expression in rat HSCs. These data could provide the evidence to support for the traditional use of Gynostemma pentaphyllum in hepatitis.

  16. The Problems and Solutions of Electroless Plating Nickel Gold in PCB Technology%化学镀镍金技术在PCB应用中的问题及解决办法

    Institute of Scientific and Technical Information of China (English)

    薛杉; 黄兆丰; 薛贝

    2011-01-01

    简单介绍了化学镀镍金工艺过程中容易出现的镀层问题,渗镀,漏镀问题及镀后印制电路板的处理等问题,根据本公司在生产过程中的经验,提出了一些可供参考的解决方案。%The problem of seepage plating,plating leakage and treatment of PCB after plating in the electroless nickel gold process was introduced.Several reference solutions according to the company's experience in the production process were proposed.

  17. Profiling of differentially expressed chemotactic-related genes in MCP-1 treated macrophage cell line using human cDNA arrays

    Institute of Scientific and Technical Information of China (English)

    Guang-Xing Bian; Hong Miao; Lei Qiu; Dong-Mei Cao; Bao-Yu Guo

    2005-01-01

    AIM: To study the global gene expression of chemotactic genes in macrophage line U937 treated with human monocyte chemoattractant protein-1 (MCP-1) through the use of ExpreeChipTMHO2 cDNA array.METHODS: Total RNA was extracted from MCP-1 treated macrophage line U937 and normal U937 cells, reversely transcribed to cDNA, and then screened in parallel with HO2 human cDNA array chip. The scanned result was additionally validated using RT-PCR.RESULTS: The result of cDNA array showed that one chemotactic-related gene was up-regulated more than two-fold (RANTES) and seven chemotactic-related genes were down-regulated more than two-fold (CCR1, CCR5,ccl16, GROβ, GROγ, IL-8 and granulocyte chemotactic protein 2) in MCP-1 treated U937 cells at mRNA level.RT-PCR analysis of four of these differentially expressed genes gave results consistent with cDNA array findings.CONCLUSION: MCP-1 could influence some chemokine and receptor expressions in macrophages in vitro. MCP-1mainly down-regulates the expression of chemotactic genes influencing neutrophilic granulocyte expression (GROβ, GROγ, IL-8 and granulocyte chemotactic protein 2), and the mRNA level of CCR5, which plays a critical role in many disorders and illnesses.

  18. Pyrrolidine dithiocarbamate (PDTC) inhibits the overexpression of MCP-1 and attenuates microglial activation in the hippocampus of a pilocarpine-induced status epilepticus rat model.

    Science.gov (United States)

    Lv, Rilang; Xu, Xiaoyun; Luo, Zheng; Shen, Nan; Wang, Feng; Zhao, Yongbo

    2014-01-01

    The aim of this study was to investigate the effects of pyrrolidine dithiocarbamate (PDTC) on MCP-1 expression and microglial activation in the hippocampus of a rat model of pilocarpine (PILO)-induced status epilepticus (SE). Moreover, seizure susceptibility, frequency and severity as well as brain damage were analyzed and changes in behavior were recorded. Chemokine MCP-1 expression and microglial activation were detected by immunohistochemistry (IHC). Fluoro-Jade C (FJC) and NeuN staining were used for the evaluation of tissue damage. Our results showed that although SE resulted in the upregulation of MCP-1 and microglial activation in the rat hippocampus 24 h after seizure onset, pretreatment with PDTC significantly inhibited the MCP-1 overexpression and attenuated the microglial activation. These effects were accompanied by neurodegenerative amelioration. To the best of our knowledge, these findings indicated for the first time that the activation of the nuclear factor-κB (NF-κB) pathway may contribute to MCP-1 upregulation and microglial activation in the context of epilepsy. PDTC was also shown to exert anticonvulsant activity and to have a neuroprotective effect on the hippocampal CA1 and CA3 regions, potentially through attenuating microglial activation.

  19. Effect of PKC-β Signaling Pathway on Expression of MCP-1 and VCAM-1 in Different Cell Models in Response to Advanced Glycation End Products (AGEs

    Directory of Open Access Journals (Sweden)

    Lisienny C. T. Rempel

    2015-05-01

    Full Text Available Advanced glycation end products (AGEs are compounds classified as uremic toxins in patients with chronic kidney disease that have several pro-inflammatory effects and are implicated in the development of cardiovascular diseases. To explore the mechanisms of AGEs–endothelium interactions through the receptor for AGEs (RAGE in the PKC-β pathway, we evaluated the production of MCP-1 and VCAM-1 in human endothelial cells (HUVECs, monocytes, and a coculture of both. AGEs were prepared by albumin glycation and characterized by absorbance and electrophoresis. The effect of AGEs on cell viability was assessed with an MTT assay. The cells were also treated with AGEs with and without a PKC-β inhibitor. MCP-1 and VCAM-1 in the cell supernatants were estimated by ELISA, and RAGE was evaluated by immunocytochemistry. AGEs exposure did not affect cell viability, but AGEs induced RAGE, MCP-1, and VCAM-1 expression in HUVECs. When HUVECs or monocytes were incubated with AGEs and a PKC-β inhibitor, MCP-1 and VCAM-1 expression significantly decreased. However, in the coculture, exposure to AGEs and a PKC-β inhibitor produced no significant effect. This study demonstrates, in vitro, the regulatory mechanisms involved in MCP-1 production in three cellular models and VCAM-1 production in HUVECs, and thus mimics the endothelial dysfunction caused by AGEs in early atherosclerosis. Such mechanisms could serve as therapeutic targets to reduce the harmful effects of AGEs in patients with chronic kidney disease.

  20. Effect of PKC-β Signaling Pathway on Expression of MCP-1 and VCAM-1 in Different Cell Models in Response to Advanced Glycation End Products (AGEs).

    Science.gov (United States)

    Rempel, Lisienny C T; Finco, Alessandra B; Maciel, Rayana A P; Bosquetti, Bruna; Alvarenga, Larissa M; Souza, Wesley M; Pecoits-Filho, Roberto; Stinghen, Andréa E M

    2015-05-14

    Advanced glycation end products (AGEs) are compounds classified as uremic toxins in patients with chronic kidney disease that have several pro-inflammatory effects and are implicated in the development of cardiovascular diseases. To explore the mechanisms of AGEs-endothelium interactions through the receptor for AGEs (RAGE) in the PKC-β pathway, we evaluated the production of MCP-1 and VCAM-1 in human endothelial cells (HUVECs), monocytes, and a coculture of both. AGEs were prepared by albumin glycation and characterized by absorbance and electrophoresis. The effect of AGEs on cell viability was assessed with an MTT assay. The cells were also treated with AGEs with and without a PKC-β inhibitor. MCP-1 and VCAM-1 in the cell supernatants were estimated by ELISA, and RAGE was evaluated by immunocytochemistry. AGEs exposure did not affect cell viability, but AGEs induced RAGE, MCP-1, and VCAM-1 expression in HUVECs. When HUVECs or monocytes were incubated with AGEs and a PKC-β inhibitor, MCP-1 and VCAM-1 expression significantly decreased. However, in the coculture, exposure to AGEs and a PKC-β inhibitor produced no significant effect. This study demonstrates, in vitro, the regulatory mechanisms involved in MCP-1 production in three cellular models and VCAM-1 production in HUVECs, and thus mimics the endothelial dysfunction caused by AGEs in early atherosclerosis. Such mechanisms could serve as therapeutic targets to reduce the harmful effects of AGEs in patients with chronic kidney disease.

  1. Human monocyte-derived dendritic cells expressing both chemotactic cytokines IL-8, MCP-1, RANTES and their receptors,and their selective migration to these chemokines

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Objective To characterize the mRNA expression of CXC chemokine IL-8, CC chemokine monocyte chemothractant protein-1 (MCP-1) and regulated on activation,normal T cell expressed and secreted (RANTES), and a newly defined DC chemokine DC- CK1 as well as the expression of IL-8 receptor, MCP-1 receptor and RANTES receptor in human monocyte derived dendritic cells (MoDCs).The migratory responsiveness of MoDC to IL-8, MCP-1 and RANTES was alsso studied. Methods In vitro generated MoDCs were obtained by differentiating monocytes in the presence of GM-CSF and IL-4 for 5 days. The time course of RNA expression was analyzed by RT-PCR and migratoly ability was assessed by a micromultiwell chemotaxis chamber assay. Results IL-8, MCP-1, RANTES and their corres ponding receptors were consistently expressed in MoDCs. DC-CK-1 expression was detectable efter 48 hours of differentiation. MoDC selectively migrated in response to MCP-1 and RANTES but not to IL-8 though transcripts of IL-8 receptor were present. Conclusion Because the capacity of dendritic cells to initiate immune responses depends on their specialized migratory and tissue homing properties, the expression of chemokines and their receptors along with the migratory responsiveness to chemokines of MoDC in our study suggests a potential role of chemokines in the interaction between dendritic cells and T cells and the induction of immune responses.

  2. CD8 T cells are involved in skeletal muscle regeneration through facilitating MCP-1 secretion and Gr1(high) macrophage infiltration.

    Science.gov (United States)

    Zhang, Jing; Xiao, Zhicheng; Qu, Chao; Cui, Wei; Wang, Xiaonan; Du, Jie

    2014-11-15

    Inflammatory microenvironments play a key role in skeletal muscle regeneration. The infiltration of CD8 T cells into injured muscle has been reported. However, the role of CD8 T cells during skeletal muscle regeneration remains unclear. In this study, we used cardiotoxin-induced mouse skeletal muscle injury/regeneration model to investigate the role of CD8 T cells. Muscle regeneration was impaired and matrix deposit was increased in CD8α-deficient mice compared with wild-type (WT) mice whose CD8 T cells were infiltrated into damaged muscle after cardiotoxin injection. Adoptive transfer of CD8 T cells to CD8α-deficient mice improved muscle regeneration and inhibited matrix remodeling. Compared with WT mice, CD8α deficiency limited the recruitment of Gr1(high) macrophages (MPs) into muscle, resulting in the reduction of satellite cell number. The expression of MCP-1 (MCP-1/CCL2), which regulates the migration of Gr1(high) MPs, was reduced in CD8α-deficient mice compared with WT mice. Coculture CD8 T cells with MPs promoted MCP-1 secretion. The i.m. injection of MCP-1 markedly promoted the recruitment of Gr1(high) MPs and improved muscle regeneration in CD8α-deficient mice. We conclude that CD8 T cells are involved in skeletal muscle regeneration by regulating the secretion of MCP-1 to recruit Gr1(high) MPs, which facilitate myoblast proliferation.

  3. Association of MCP-1-2518A/G polymorphism with uveitis susceptibility: a Meta-analysis%MCP-1基因-2518A/G多态性与葡萄膜炎易感性的Meta分析

    Institute of Scientific and Technical Information of China (English)

    张小玲; 冀垒兵; 高晓唯; 肖云; 章玮; 张燕

    2015-01-01

    Background Monocyte chemoattractant protein-1 (MCP-1) polymorphisms are demonstrated to be significantly associated with the susceptibility to uveitis in recent years,while a consistent conclusion for the association of MCP-1-2518A/G polymorphism and uveitis risk is not reached yet.Objective This study was to comprehensively investigate the correlation between MCP-1-2518A/G polymorphism and uveitis susceptibility.Methods General searches of electronic database including PubMed,Embase,Web of Science,CNKI,VIP,Wanfang database and China biomedical literature database (CBD) were performed to retrieve published case-control studies regarding the association between MCP-1-2518A/G polymorphism and uveitis risk.The data were screened according to the inclusion and exclusion criteria and extracted,and the quality of included studies was evaluated.The pooled odds ratios (OR) with 95% confidence intervals (CI) were calculated.Publication bias and sensitivity analysis were also assessed.All statistical analyses were conducted with RevMan 5.2 and Stata 12.0 software.Results A total of 8 eligible case-control studies involving 1 197 cases and 1 570 controls were included in the Meta-analysis.The results showed no significant association of MCP-1-2518A/G polymorphism with uveitis susceptibility in the G vs.A,GG vs.AA and GG vs.AG+AA models (all at P>0.05).MCP-1-2518A/G polymorphism was found to be significantly associated with uveitis risk in the GG+AG vs.AA model (P =0.01,OR =1.25,95% CI:1.06-1.48),while no significant association was found by the sensitive analysis (GG + AG vs.AA:P =0.19,OR =1.16,95% CI:0.93-1.45).The subgroup analysis by uveitis types revealed that the individuals carrying allele-G or GG genotype harbored a significantly increased risk for anterior uveitis (G vs.A:P=0.01,OR=1.49,95% CI:1.16-1.90;GG vs.AA:P=0.01,OR=2.09,95% CI:1.21-3.61;GG+AG vs.AA:P=0.01,OR=1.58,95% CI:1.12-2.23;GG vs.AG+AA:P=0.01,OR=1.78,95% CI:1.12-2.83).The individuals with

  4. 全数字化无版印刷--印刷工业颠覆性技术%Full Digital Non-plate Printing ---Subversive Technology in Printing Industry

    Institute of Scientific and Technical Information of China (English)

    李合成; 蒋丽艳

    2016-01-01

    日益加重的大气污染和雾霾已经成为国内外大众关注的焦点,传统印刷过程中普通印刷油墨的VOCs排放,使得传统印刷工业的污染不断受到公众的质疑和诟病。网络出版和其他媒体传播方式的不断发展,使得传统印刷长版印刷活件变得越来越少;商品包装,尤其是药品、食品包装的安全和可追溯要求,使得原有包装印刷、标签印刷品上必须带有可变数据信息。这些需求和变化是传统印刷无法满足和逾越的,而数字化无版印刷技术,则因为其无需制版、全过程数字化处理、可实现单张可变数据和节能减排,从而可以替代传统有版印刷。可以预测,全数字无版印刷将成为未来印刷工业的颠覆性技术。%Air pollution and smog has become increasingly severe ,which has been gotten more and more attention from home and aboard .In addition , the VOCs of general printing ink in the traditional printing process has also made the industrial pollution questioned and criticized ceaselessly. The continuous development of network publishing and other ways of media communication have brought about that the traditional printing and the long-run printing have become less and less. The requirements of safety and traceability of packaging, especially drugs and food packaging ,have made the ordinary packaging printing and label printing be necessarily with the variable Data ,which leads that the traditional printing can not meet or exceed the changes .The digital printing technology which is full-digital and without plate-making can realize the variable data printing of the single-page、energy conservation and emission reduction, and can replace the traditional printing. It can be predicted that the full-digital printing will be the subversive technology in the future of the printing industry.

  5. Research on metal-plated cellulose nitrate flakes and their infrared / millimeter wave characteristics

    Science.gov (United States)

    Ye, Shu-qin; Zhu, Chen-guang; Wang, Li-hong; Ou'yang, De-hua; Pan, Gong-pei

    2016-10-01

    Copper-plated and silver-plated cellulose nitrate flakes, which were prepared by using chemical plating technology, were used to jam infrared detector and millimeter-wave radar. It was tested for the conductivity and infrared jamming performance of plating and also the RCS (Radar Cross Section) performance of millimeter-wave radar. Test results showed that the prepared metal-plated cellulose nitrate flakes have obvious conductivity, and infrared total radiation energy of silver plating and copper plating had approximately increased 32% and 21% respectively. Through determination, the millimeter-wave reflecting property and RCS of silver-plated cellulose nitrate flakes were higher than that of copper-plated cellulose nitrate flakes. Therefore, silver-plated cellulose nitrate flakes can be used as an effective infrared / millimeter wave composite jamming material.

  6. High resolution, two-dimensional imaging, microchannel plate detector for use on a sounding rocket experiment

    Science.gov (United States)

    Bush, Brett C.; Cotton, Daniel M.; Siegmund, Oswald H.; Chakrabarti, Supriya; Harris, Walter; Clarke, John

    1991-01-01

    We discuss a high resolution microchannel plate (MCP) imaging detector to be used in measurements of Doppler-shifted hydrogen Lyman-alpha line emission from Jupiter and the interplanetary medium. The detector is housed in a vacuum-tight stainless steel cylinder (to provide shielding from magnetic fields) with a MgF2 window. Operating at nominal voltage, the four plate configuration provides a gain of 1.2 x 10 exp 7 electrons per incident photon. The wedge-and-strip anode has two-dimensional imaging capabilities, with a resolution of 40 microns FWHM over a one centimeter diameter area. The detector has a high quantum efficiency while retaining a low background rate. A KBr photocathode is used to enhance the quantum efficiency of the bare MCPs to a value of 35 percent at Lyman-alpha.

  7. Bending and stretching of plates

    CERN Document Server

    Mansfield, E H; Hemp, W S

    1964-01-01

    The Bending and Stretching of Plates deals with elastic plate theory, particularly on small- and large-deflexion theory. Small-deflexion theory concerns derivation of basic equations, rectangular plates, plates of various shapes, plates whose boundaries are amenable to conformal transformation, plates with variable rigidity, and approximate methods. Large-deflexion theory includes general equations and some exact solutions, approximate methods in large-deflexion theory, asymptotic large-deflexion theories for very thin plates. Asymptotic theories covers membrane theory, tension field theory, a

  8. A plating method for metal coating of fiber Bragg grating

    Institute of Scientific and Technical Information of China (English)

    Yulong Li; Hua Zhang; Yan Feng; Gang Peng

    2009-01-01

    We present a method for metal coating optical fiber and in-fiber Bragg grating. The technology process which is based on electroless plating and electroplating method is described in detail. The fiber is firstly coated with a thin copper or nickel plate with electroless plating method. Then, a thicker nickel plate is coated on the surface of the conductive layer. Under the optimum conditions, the surfaces of chemical plating and electroplating coatings are all smooth and compact. There is no visible defect found in the cross-section. Using this two-step metallization method, the in-fiber Bragg grating can be well protected and its thermal sensitivity can be enhanced. After the metallization process, the fiber sensor is successfully embedded in the 42CrMo steel by brazing method. Thus a smart metal structure is achieved. The embedding results show that the plating method for metallization protection of in-fiber Bragg grating is effective.

  9. Height Adjustment Technology for Induction Plate of Linear Motor in Line%直线电机线路感应板高度调整技术探讨

    Institute of Scientific and Technical Information of China (English)

    席雷

    2012-01-01

    感应板是直线电机线路中的重要设备,文章对感应板高度调整工作的特点进行了介绍,并进一步分析了感应板高度变化的原因,在此基础上提出了感应板高度调整工作的若干建议。%The induction plate is an important component of linear motor, the paper describes characteristics of the induction plate height adjustment work, and further analyzes the reasons of induction plate height changes. Based on it, recommendations are made on the induction plate height adjustment work.

  10. Development of Electroless Copper and Gold Plating on Wood

    Institute of Scientific and Technical Information of China (English)

    ZHOUGao; ZHAOGuangjie

    2004-01-01

    The use of more and more electron products requires interior wood products to have the performance of electromagnetic shielding. One of the ways to realize it is to introduce the chemical plating which has already been developed in electron industry into wood processing. The paper clarifies the mechanism of electroless copper and gold plating and its application to wood. It emphasizes the development and technology of electroless copper and gold plating on wood. Meanwhile, it points out that it is highly feasible to take this technology into effect.

  11. The relationship of urinary MCP1、 fetuin-A expression and urinary MDA in patients with nephrolithiasis%肾结石患者尿液MCP-1、胎球蛋白-A表达与MDA的关系

    Institute of Scientific and Technical Information of China (English)

    孙春

    2015-01-01

    目的:探讨肾结石患者尿液炎症细胞因子变化以及氧化应激在结石形成中的作用.方法:选择75例草酸钙结石住院患者,随机挑选25例健康人作正常对照组.收集两组人的晨尿,分别运用ELLISA法和TBA法检测尿液中单核细胞趋化蛋白(MCP-1)、胎球蛋白-A (Fetuin-A)及丙二醛(MDA)的含量.结果:MCP-1在结石组含量为212.45 (59.24,673.50)pg/mg cr,在对照组为74.36(22.45,203.57)pg/mg cr,结石组高于对照组(P<0.05);胎球蛋白-A在结石组为320.80(42.28,1819.85)ng/mg cr,在对照组为787.94(187.03,3269.17)ng/mg cr,结石组低于对照组(P<0.05);MDA在结石组高于正常对照组(P<0.05).相关性分析:结石组尿液MCP-1和MDA不相关,r=0.045,P> 0.05;胎球蛋白-A和MDA不相关,r=-0.016,P> 0.05.结论:尿液炎症细胞因子变化和氧化应激损伤可能在肾结石形成中起作用,但是氧化应激损伤可能未参与尿液炎症细胞因子的调节.

  12. Anterior cervical plating

    Directory of Open Access Journals (Sweden)

    Gonugunta V

    2005-01-01

    Full Text Available Although anterior cervical instrumentation was initially used in cervical trauma, because of obvious benefits, indications for its use have been expanded over time to degenerative cases as well as tumor and infection of the cervical spine. Along with a threefold increase in incidence of cervical fusion surgery, implant designs have evolved over the last three decades. Observation of graft subsidence and phenomenon of stress shielding led to the development of the new generation dynamic anterior cervical plating systems. Anterior cervical plating does not conclusively improve clinical outcome of the patients, but certainly enhances the efficacy of autograft and allograft fusion and lessens the rate of pseudoarthrosis and kyphosis after multilevel discectomy and fusions. A review of biomechanics, surgical technique, indications, complications and results of various anterior cervical plating systems is presented here to enable clinicians to select the appropriate construct design.

  13. Storage of strawberries (Fragaria ananassa L. cv. ‘Oso Grande’, subjected to 1-MCP - doi: 10.4025/actascitechnol.v34i3.8790

    Directory of Open Access Journals (Sweden)

    Polyanna Alves Silva

    2012-05-01

    Full Text Available This study aimed to investigate the influence of 1 - methylcyclopropene (1-MCP on the substances involved in the softening of strawberry, cultivar Oso Grande, stored at room temperature, from the municipality of Itutinga, State of Minas Gerais. The parameters evaluated were: firmness, total pectin, percentage of solubilization, activities of the enzymes pectinmethylesterase (PME (EC 3.1.1.11 and polygalacturonase (PG (EC 3.2.1.15. It was concluded that 1-MCP delayed the softening of the fruits, since the fruits that were treated with 1-MCP after storage, have shown greater firmness, lower activities of PG and PME, and lower contents of total pectin, soluble pectin and percentage of solubilization. 

  14. License plate detection algorithm

    Science.gov (United States)

    Broitman, Michael; Klopovsky, Yuri; Silinskis, Normunds

    2013-12-01

    A novel algorithm for vehicle license plates localization is proposed. The algorithm is based on pixel intensity transition gradient analysis. Near to 2500 natural-scene gray-level vehicle images of different backgrounds and ambient illumination was tested. The best set of algorithm's parameters produces detection rate up to 0.94. Taking into account abnormal camera location during our tests and therefore geometrical distortion and troubles from trees this result could be considered as passable. Correlation between source data, such as license Plate dimensions and texture, cameras location and others, and parameters of algorithm were also defined.

  15. Involvement of M3 Cholinergic Receptor Signal Transduction Pathway in Regulation of the Expression of Chemokine MOB-1, MCP-1 Genes in Pancreatic Acinar Cells

    Institute of Scientific and Technical Information of China (English)

    郑海; 陈道达; 张景輝; 田原

    2004-01-01

    Whether M3 cholinergic receptor signal transduction pathway is involved in regulation of the activation of NF-κB and the expression of chemokine MOB-1, MCP-1genes in pancreatic acinar cells was investigated. Rat pancreatic acinar cells were isolated, cultured and treated with carbachol, atropine and PDTC in vitro. The MOB-1 and MCP-1 mRNA expression was detected by using RT-PCR. The activation of NF-κB was monitored by using electrophoretic mobility shift assay.The results showed that as compared with control group, M3 cholinergic receptor agonist (103mol/L, 104-4ol/L carbachol) could induce a concentration-dependent and time-dependent increase in the expression of MOB-1, MCP-1 mRNA in pancreatic acinar cells. After treatment with 10 -3mol/L carbachol for 2 h, the expression of MOB-1, MCP-1 mRNA was strongest. The activity of NF-κB in pancreatic acinar cells was significantly increased (P<0.01) after treated with M3 cholinergic receptor agonist (10-3 mol/L carbachol) in vitro for 30 min. Either M3 cholinergic receptor antagonist (10-5 mol/L atropine) or NF-κB inhibitor (10-2 mol/L PDTC) could obviously inhibit the activation of NF-κB and the chemokine MOB-1, MCP-1 mRNA expression induced by carbachol (P <0.05). This inhibitory effect was significantly increased by atropine plus PDTC (P<0.01). The results of these studies indicated that M3 cholinergic receptor signal transduction pathway was likely involved in regulation of the expression of chemokine MOB-1 and MCP-1genes in pancreatic acinar cells in vitro through the activation of NF-κB.

  16. Casimir force between metal plate and dielectric plate

    Institute of Scientific and Technical Information of China (English)

    刘中柱; 邵成刚; 罗俊

    1999-01-01

    The Casimir effect between metal plate and dielectric plate is discussed with 1+1-dimensional potential model without using cut-off method. Calculation shows that the Casimir force between metal plate and dielectric plate is determined not only by the potential V0, the dielectric thickness and the distance α between the metal plate and dielectric plate, but also by the dimension of the vessel. When α is far less than the dimension of the vessel, the Casimir force Fc∝α(-1); conversely Fc∝α-2. This result is significant for Casimir force experiment.

  17. Nuclear NF-κB p65 in peripheral blood mononuclear cells correlates with urinary MCP-1, RANTES and the severity of type 2 diabetic nephropathy.

    Directory of Open Access Journals (Sweden)

    Bin Yi

    Full Text Available AIMS: To investigate if nuclear NF-κB p65 expression in ex vivo isolated peripheral blood mononuclear cells correlates with urinary MCP-1 or RANTES and the severity of type 2 diabetic nephropathy. METHODS: According to their urinary albumin-to-creatinine ratio (uACR, 107 patients with type 2 diabetes (eGFR >60 ml/min were divided into normal albuminuria group (DN0 group, 38 cases, microalbuminuria group (DN1 group, 38 cases, and macroalbuminuria group (DN2 group, 31 cases, compared with matched healthy normal control group (NC group, 30 cases. Nuclear NF-κB p65 protein expression levels in peripheral blood mononuclear cells were detected by western blotting. Real-time quantitative polymerase chain reaction was used to detect NF-κB p65 mRNA expression and ELISA assay was used to detect the levels of urinary MCP-1 and RANTES. RESULTS: Nuclear NF-κB p65 protein and NF-κB p65 mRNA expression levels in peripheral blood mononuclear cells, urinary MCP-1/Cr and RANTES/Cr were all significantly higher in all diabetes groups as compared with NC group. In particular, the increase of nuclear NF-κB p65 protein and NF-κB p65 mRNA expressions, urinary MCP-1/Cr and RANTES/Cr all correlated with the severity of type 2 diabetic nephropathy as indicated by the increase in uACR. Pearson correlation analysis indicated that both urinary MCP-1/Cr and RANTES/Cr were positively correlated with nuclear NF-κB p65 protein or NF-κB p65 mRNA levels. Stepwise multiple regression analysis showed that nuclear NF-κB p65 protein or NF-κB p65 mRNA was an independent variable for urinary MCP-1/Cr, and MCP-1/Cr and RANTES/Cr were two independent variables for uACR. CONCLUSION: Our research demonstrates that nuclear NF-κB p65 protein and mRNA expressions in ex vivo isolated peripheral blood mononuclear cells well correlate with urinary MCP-1/Cr, RANTES/Cr and the severity of type 2 diabetic nephropathy.

  18. Association of monocyte chemoattractant protein-1 (MCP-1)-2518A>G polymorphism with susceptibility to coronary artery disease: a meta-analysis.

    Science.gov (United States)

    Bai, Xiao-Yan; Li, Shujing; Wang, Miao; Qu, Xinjian; Hu, Gaolei; Xu, Zhaowei; Chen, Min; He, Guo-Wei; Wu, Huijian

    2015-05-01

    We attempted to systematically elucidate the association between monocyte chemoattractant protein-1 (MCP-1) -2518A>G polymorphism and risk of coronary artery disease (CAD). Eligible studies were identified through PubMed, EBSCO, and Web of Science Databases. The magnitude of MCP-1 polymorphism effect and its possible mode of action on CAD were estimated. The odds ratio (OR) with 95% confidence intervals (CI) were pooled in a specific genetic model to assess the association. A total of 21 studies were involved. There was significant gene effect on CAD risk in the overall population (likelihood ratio test: p G polymorphism may be associated with susceptibility to CAD, especially in Caucasians.

  19. Qualidade de caqui 'Rama forte' após armazenamento refrigerado, influenciada pelos tratamentos 1-MCP e/ou CO2

    Directory of Open Access Journals (Sweden)

    João Peterson Pereira Gardin

    2012-12-01

    Full Text Available Avaliaram-se os efeitos dos tratamentos com CO2 e 1-MCP (1-metilciclopropeno sobre a adstringência (índice de tanino, firmeza da polpa e distúrbios da epiderme em caqui 'Rama Forte'. Frutos foram tratados com 1-MCP por 24 h, logo após a colheita e/ou com alto CO2 (70% por 24 ou 48 h, um dia após a colheita ou após o armazenamento refrigerado (AR. Os caquis foram armazenados sob atmosfera modificada a 0 ºC, por 45 dias, e a seguir mantidos a 23 ºC, por 9 dias. Frutos-controle (não tratados com 1-MCP nem com CO2 amoleceram em três dias e perderam aproximadamente 50% da adstringência em 6 dias após o AR. A exposição ao CO2 acelerou a redução da adstringência. Esse efeito do CO2 foi menor em frutos tratados com 1-MCP, especialmente quando o CO2 foi aplicado após o AR, por apenas 24 h. O tratamento com 1-MCP inibiu o amolecimento e a redução da adstringência, especialmente nos frutos não tratados com CO2. O amolecimento de frutos tratados com 1-MCP foi maior quando a exposição ao CO2 ocorreu antes do AR. A combinação dos tratamentos com 1-MCP e alto CO2 reduziu a incidência de podridões e manchas translúcidas, mas não alterou o desenvolvimento de pintas pretas ('estrias'. Os resultados indicam que é possível induzir perda da adstringência sem excessiva perda da firmeza da polpa de caquis 'Rama Forte' após o AR pela associação dos tratamentos com 1-MCP logo após a colheita e alto CO2 após o AR.

  20. Application Research of MCP23016 in Intelligent Multiplex Control System%MCP23016在智能化多路控制系统中的应用研究

    Institute of Scientific and Technical Information of China (English)

    包敬海; 吕丽珊; 彭丽英

    2016-01-01

    随着物联网的快速发展,智能化系统的应用日益广泛。但是,微控制器的IO端口有限,难以应对日益繁多的外部设备的控制需求。针对此难题,应利用IIC扩展芯片实现多路控制进行解决。以超低功耗MSP430G2253为主控芯片,通过16位IIC芯片MCP23016进行扩展,配合Web Server,使用户能够通过手机随时随地的对1024条线路的通断进行远程控制。实践表明,该系统具有扩展能力强、稳定可靠、响应快速、成本低廉等优点。%With the rapid development of internet of things, the application of intelligent system has become increasingly pop-ular. However, the IO ports of micro-controller is limited and can not cope with the control demand of increasing external equip-ment. Targeting at this problem, this paper proposed to use the IIC chip to realize the intelligent multiplex control, which took the ultra-low power consumption MSP430G2553 as the control core, extended the IO port by MCP23016, coordinated with the Web Server, and finally realized the user’ s remote control 1024 lines on-off whenever and wherever by mobile phone. Practice showed that the system had the advantages of strong extension, great stability and reliability, fast response and low cost.

  1. Nuclear reactor alignment plate configuration

    Energy Technology Data Exchange (ETDEWEB)

    Altman, David A; Forsyth, David R; Smith, Richard E; Singleton, Norman R

    2014-01-28

    An alignment plate that is attached to a core barrel of a pressurized water reactor and fits within slots within a top plate of a lower core shroud and upper core plate to maintain lateral alignment of the reactor internals. The alignment plate is connected to the core barrel through two vertically-spaced dowel pins that extend from the outside surface of the core barrel through a reinforcement pad and into corresponding holes in the alignment plate. Additionally, threaded fasteners are inserted around the perimeter of the reinforcement pad and into the alignment plate to further secure the alignment plate to the core barrel. A fillet weld also is deposited around the perimeter of the reinforcement pad. To accomodate thermal growth between the alignment plate and the core barrel, a gap is left above, below and at both sides of one of the dowel pins in the alignment plate holes through with the dowel pins pass.

  2. Create Your Plate

    Medline Plus

    Full Text Available ... 1 Type 2 About Us Online Community Meal Planning Sign In Search: Search More Sites Search ≡ Are ... Fitness Home Food MyFoodAdvisor Recipes Association Cookbook Recipes Planning Meals Diabetes Meal Plans Create Your Plate Gluten ...

  3. Create Your Plate

    Medline Plus

    Full Text Available ... Create Your Plate is a simple and effective way to manage your blood glucose levels and lose weight. With ... year of delicious meals to help prevent and manage diabetes. Healthy Recipes: ... to your day with this guide. Ways to Give: Wear Your Cause on Your Sleeve - ...

  4. The Plate Tectonics Project

    Science.gov (United States)

    Hein, Annamae J.

    2011-01-01

    The Plate Tectonics Project is a multiday, inquiry-based unit that facilitates students as self-motivated learners. Reliable Web sites are offered to assist with lessons, and a summative rubric is used to facilitate the holistic nature of the project. After each topic (parts of the Earth, continental drift, etc.) is covered, the students will…

  5. Create Your Plate

    Medline Plus

    Full Text Available ... tax-deductible gift today can fund critical diabetes research and support vital diabetes education services that improve the ... way to manage your blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ...

  6. Create Your Plate

    Medline Plus

    Full Text Available ... 1 Type 2 About Us Online Community Meal Planning Sign In Search: Search More Sites Search ≡ Are ... Fitness Home Food MyFoodAdvisor Recipes Association Cookbook Recipes Planning Meals Diabetes Meal Plans Create Your Plate Gluten ...

  7. Create Your Plate

    Medline Plus

    Full Text Available ... tax-deductible gift today can fund critical diabetes research and support vital diabetes education services that improve the ... way to manage your blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ...

  8. Create Your Plate

    Medline Plus

    Full Text Available ... unsweetened tea or coffee. Featured Product Precise Portions® Go Healthy Travel Pack (4/Box) Taking the guesswork ... you are. Now, our best-selling, sectioned to-go plate with easy-sealing lid is offered in ...

  9. Create Your Plate

    Medline Plus

    Full Text Available ... manage portion control wherever you are. Now, our best-selling, sectioned to-go plate with easy-sealing lid is offered in a 4-pack. Whether ... Research & Practice We Are Research Leaders We Support Your Doctor ...

  10. INL HIP Plate Fabrication

    Energy Technology Data Exchange (ETDEWEB)

    B. H. Park; C. R. Clark; J. F. Jue

    2010-02-01

    This document outlines the process used to bond monolithic fuel plates by Hot Isostatic Pressing (HIP). This method was developed at Idaho National Laboratory (INL) for the Reduced Enrichment for Research and Test Reactors (RERTR) program. These foils have been used in a number of irradiation experiments in support of the United States Global Threat Reduction Initiative (GTRI) program.

  11. The Plate Tectonics Project

    Science.gov (United States)

    Hein, Annamae J.

    2011-01-01

    The Plate Tectonics Project is a multiday, inquiry-based unit that facilitates students as self-motivated learners. Reliable Web sites are offered to assist with lessons, and a summative rubric is used to facilitate the holistic nature of the project. After each topic (parts of the Earth, continental drift, etc.) is covered, the students will…

  12. Create Your Plate

    Medline Plus

    Full Text Available ... Planning Meals > Create Your Plate Share: Print Page Text Size: A A A Listen En Español Create ... somewhere in between, you have an easy portion control solution that works. Last Reviewed: October 8, 2015 Last Edited: ... Cost of Diabetes Advocate Toolkit Call to Congress Research & ...

  13. Dosimetric properties of TL foils based on LiF:Mg,Cu,P (MCP-N) phosphors for clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Kisielewicz, K., E-mail: z5kisiel@cyf-kr.edu.p [Centre of Oncology, Maria Sklodowska - Curie Memorial Institute, Krakow Branch, ul. Garncarska 11, 31-115 Krakow (Poland); Swiebocka, J. [Faculty of Physics and Applied Computer Science, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Krakow (Poland); Czopyk, L.; Klosowski, M. [Institute of Nuclear Physics, Polish Academy of Sciences, ul. Radzikowskiego 152, 31-342 Krakow (Poland); Lesiak, J.; Byrski, E.; Kabat, D.; Wawrzak, M.; Sladowska, A.; Dziecichowicz, A. [Centre of Oncology, Maria Sklodowska - Curie Memorial Institute, Krakow Branch, ul. Garncarska 11, 31-115 Krakow (Poland); Olko, P. [Institute of Nuclear Physics, Polish Academy of Sciences, ul. Radzikowskiego 152, 31-342 Krakow (Poland); Waligorski, M.P.R. [Centre of Oncology, Maria Sklodowska - Curie Memorial Institute, Krakow Branch, ul. Garncarska 11, 31-115 Krakow (Poland); Institute of Nuclear Physics, Polish Academy of Sciences, ul. Radzikowskiego 152, 31-342 Krakow (Poland)

    2010-03-15

    Two prototype 2-D thermoluminescence (TL) readers: a laboratory reader equipped with a sensitive 640 x 480 pixel CCD camera and a heater planchet of 7.2 cm diameter, and a clinical reader with a 14-bit CCD PCO camera of 1024 x 1024 pixel resolution and a 20 x 20 cm{sup 2} heater, were developed at the Institute of Nuclear Physics (IFJ PAN) in Krakow, Poland. These readers are able to produce digital images of 2-D dose distributions from exposed TL foils of sizes up to 20 x 20 cm{sup 2}, composed of ETFE (ethylene tetrafluoroethylene) and LiF:Mg,Cu,P (MCP-N) powder, also developed and manufactured at IFJ PAN in Krakow. The clinical 2-D TL system is being developed specifically for clinical measurements of 2-D dose distributions in external photon or electron radiotherapy beams and around small sources applied in brachytherapy. We report results of our tests of basic dosimetric properties (repeatability, linearity vs. absorbed dose, signal-to-noise ratio and energy dependence) of the 2-D TL foil-reader systems using MCP-N based foils and megavolt X-ray radiotherapy beams, over a range of dose relevant to clinical radiotherapy. We conclude that the clinical 2-D TL system may be useful in clinical dosimetry of external radiotherapy beams and photon-emitting brachytherapy sources. As examples of such applications, we show verification of computer therapy planning system calculations of fields produced by multileaf collimators or stereotactic radiosurgery systems, performed as part of the quality assurance procedure in radiotherapy.

  14. Genetic polymorphisms of RANTES, IL1-A, MCP-1 and TNF-A genes in patients with prostate cancer

    Directory of Open Access Journals (Sweden)

    Tallada Miguel

    2008-12-01

    Full Text Available Abstract Background Inflammation has been implicated as an etiological factor in several human cancers, including prostate cancer. Allelic variants of the genes involved in inflammatory pathways are logical candidates as genetic determinants of prostate cancer risk. The purpose of this study was to investigate whether single nucleotide polymorphisms of genes that lead to increased levels of pro-inflammatory cytokines and chemokines are associated with an increased prostate cancer risk. Methods A case-control study design was used to test the association between prostate cancer risk and the polymorphisms TNF-A-308 A/G (rs 1800629, RANTES-403 G/A (rs 2107538, IL1-A-889 C/T (rs 1800587 and MCP-1 2518 G/A (rs 1024611 in 296 patients diagnosed with prostate cancer and in 311 healthy controls from the same area. Results Diagnosis of prostate cancer was significantly associated with TNF-A GA + AA genotype (OR, 1.61; 95% CI, 1.09–2.64 and RANTES GA + AA genotype (OR, 1.44; 95% CI, 1.09–2.38. A alleles in TNF-A and RANTES influenced prostate cancer susceptibility and acted independently of each other in these subjects. No epistatic effect was found for the combination of different polymorphisms studied. Finally, no overall association was found between prostate cancer risk and IL1-A or MCP-1 polymorphisms. Conclusion Our results and previously published findings on genes associated with innate immunity support the hypothesis that polymorphisms in proinflammatory genes may be important in prostate cancer development.

  15. Genetic polymorphisms of RANTES, IL1-A, MCP-1 and TNF-A genes in patients with prostate cancer

    Science.gov (United States)

    Sáenz-López, Pablo; Carretero, Rafael; Cózar, José Manuel; Romero, José Maria; Canton, Julia; Vilchez, José Ramón; Tallada, Miguel; Garrido, Federico; Ruiz-Cabello, Francisco

    2008-01-01

    Background Inflammation has been implicated as an etiological factor in several human cancers, including prostate cancer. Allelic variants of the genes involved in inflammatory pathways are logical candidates as genetic determinants of prostate cancer risk. The purpose of this study was to investigate whether single nucleotide polymorphisms of genes that lead to increased levels of pro-inflammatory cytokines and chemokines are associated with an increased prostate cancer risk. Methods A case-control study design was used to test the association between prostate cancer risk and the polymorphisms TNF-A-308 A/G (rs 1800629), RANTES-403 G/A (rs 2107538), IL1-A-889 C/T (rs 1800587) and MCP-1 2518 G/A (rs 1024611) in 296 patients diagnosed with prostate cancer and in 311 healthy controls from the same area. Results Diagnosis of prostate cancer was significantly associated with TNF-A GA + AA genotype (OR, 1.61; 95% CI, 1.09–2.64) and RANTES GA + AA genotype (OR, 1.44; 95% CI, 1.09–2.38). A alleles in TNF-A and RANTES influenced prostate cancer susceptibility and acted independently of each other in these subjects. No epistatic effect was found for the combination of different polymorphisms studied. Finally, no overall association was found between prostate cancer risk and IL1-A or MCP-1 polymorphisms. Conclusion Our results and previously published findings on genes associated with innate immunity support the hypothesis that polymorphisms in proinflammatory genes may be important in prostate cancer development. PMID:19099590

  16. Tailoring the Electromagnetic Near Field with Patterned Surfaces: Near-Field Plates

    Science.gov (United States)

    2014-12-10

    near-field plates possible. A linear near-field plate is shown in Fig. 1, which can create a subwavelength line (1D) focus when excited by an...concentric annular slots on a circular grounded dielectric slab. The plate is excited through a coaxial cable and its rim is short circuited. The slots are...standard printed circuit board technology. The plates consist of concentric annular slots on a circular grounded dielectric slab excited through a coaxial

  17. Study of Static Microchannel Plate Saturation Effects for the Fast Plasma Investigation Dual Electron Spectrometers on NASA's Magnetospheric MultiScale Mission

    Science.gov (United States)

    Avanov, L. A.; Gliese, U.; Pollock, C. J.; Moore, T. E.; Chornay, D. J.; Barrie, A. C.; Kujawski, J. T.; Gershman, D. J.; Tucker, C. J.; Mariano, A.; Smith, D. L.; Jacques, A. D.

    2015-01-01

    Imaging detecting systems based on microchannel plates (MCPs) are the most common for low energy plasma measurements for both space borne and ground applications. One of the key parameters of these detection systems is the dynamic range of the MCP's response to the input fluxes of charged particles. For most applications the dynamic range of the linear response should be as wide as possible. This is especially true for the Dual Electron Spectrometers (DESs) of the Fast Plasma Investigation (FPI) on NASA's Magnetospheric MultiScale (MMS) mission because a wide range of input fluxes are expected. To make use of the full available dynamic range, it is important to understand the MCP response behavior beyond the linear regime where the MCPs start to saturate. We have performed extensive studies of this during the characterization and calibration of the DES instruments and have identified several saturation effects of the detection system. The MCP itself exhibits saturation when the channels lack the ability to replenish charge sufficiently rapidly. It is found and will be shown that the ground system can significantly impact the correct measurement of this effect. As the MCP starts to saturate, the resulting pulse height distribution (PHD) changes shape and location (with less pulse height values), which leads to truncation of the PHD by the threshold set on the detection system discriminator. Finally, the detection system pulse amplifier exhibits saturation as the input flux drives pulse rates greater than its linear response speed. All of these effects effectively change the dead time of the overall detection system and as a result can affect the quality and interpretation of the flight data. We present results of detection system saturation effects and their interaction with special emphasis on the MCP related effects.

  18. Low Cost PEM Fuel Cell Metal Bipolar Plates

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Conghua [TreadStone Technologies, Inc.

    2013-05-30

    Bipolar plate is an important component in fuel cell stacks and accounts for more than 75% of stack weight and volume. The technology development of metal bipolar plates can effectively reduce the fuel cells stack weight and volume over 50%. The challenge is the metal plate corrosion protection at low cost for the broad commercial applications. This project is aimed to develop innovative technological solutions to overcome the corrosion barrier of low cost metal plates. The feasibility of has been demonstrated and patented (US Patent 7,309,540). The plan is to further reduce the cost, and scale up the technology. The project is built on three pillars: 1) robust experimental evidence demonstrating the feasibility of our technology, 2) a team that consists of industrial leaders in fuel cell stack application, design, and manufactures; 3) a low-risk, significant-milestone driven program that proves the feasibility of meeting program objectives The implementation of this project will reduce the fuel cell stack metal bipolar separator plate cost which accounts 15-21% of the overall stack cost. It will contribute to the market adoption of fuel cell technologies. In addition, this corrosion protection technology can be used similar energy devices, such as batteries and electrolyzers. Therefore, the success of the project will be benefit in broad markets.

  19. Test beam results of micro channel plates in 'ionisation mode' for the detection of single charged particle and electromagnetic showers

    Energy Technology Data Exchange (ETDEWEB)

    Barnyakov, A.; Barnyakov, M. [Budker Institute of Nuclear Physics, pr. Akademika Lavrentieva, 11, Novosibirsk, (Russian Federation); Novosibirsk State University, str. Pirogova 2, Novosibirsk, (Russian Federation); Brianza, L.; Ghezzi, A.; Gotti, C.; Govoni, P.; Martelli, A.; Marzocchi, B.; Pigazzini, S.; Tabarelli de Fatis, T.; Trevisani, N. [Universita di Milano Bicocca and INFN, Sezione di Milano-Bicocca,, Piazza della Scienza 3, I-20126, Milano, (Italy); Cavallari, F.; Del Re, D.; Gelli, S.; Jorda Lope, C.; Meridiani, P.; Organtini, G.; Paramatti, R.; Pernie, L.; Rahatlou, S.; Rovelli, C.; Santanastasio, F. [Universita di Roma ' La Sapienza' and INFN, Sezione di Roma1, P.le A. Moro 1, I-00044 Rome, (Italy)

    2015-07-01

    IMCP is an R and D project aimed at the exploitation of secondary emission of electrons from the surface of microchannel plates (MCP) for fast timing of showers in high rate environments. The usage of MCPs in 'ionisation' mode has long been proposed and is used extensively in ion time-of-flight mass spectrometers. What has not been investigated in depth is their use to detect the ionizing component of showers. The fast time resolution of MCPs exceeds anything that has been previously used in calorimeters, and, if exploited effectively, could aid in the event reconstruction at high luminosities. Results from tests with electrons with energies up to 150 GeV of MCP devices with different characteristics will be presented, in particular detection efficiency and time resolution. (authors)

  20. MyPlate Food Guide

    Science.gov (United States)

    ... Choosing the Right Sport for You Shyness MyPlate Food Guide KidsHealth > For Teens > MyPlate Food Guide Print ... other sugary drinks. Avoid oversized portions. continue Five Food Groups Different food groups meet different nutrition needs. ...

  1. What Are Growth Plate Injuries?

    Science.gov (United States)

    ... plate injuries are:  Falling down  Competitive sports (like football)  Recreational activities. Other reasons for growth plate injuries are:  Child abuse  Injury from extreme cold (for ...

  2. Concentrações de IL-6, TNF-α e MCP-1 em crianças com excesso de massa corporal

    Directory of Open Access Journals (Sweden)

    Juliano Magalhães Guedes

    2015-08-01

    Full Text Available O objetivo desta revisão sistemática foi verificar a relação das concentrações de IL-6, TNF-α e MCP-1 em crianças com excesso de massa corporal. As bases de dados investigadas PUBMED, SciELO, LILACS e Periódico Capes foram consultadas retrospectivamente para os últimos seis anos (2009 a 2014 utilizando combinações de palavras chaves como inflamação, IL-6, TNF-α, MCP-1 combinadas com crianças e escolares. Foram analisados 21 artigos. Foi encontrado associação entre sobrepeso/obesidade com IL-6, TNF-α e MCP-1 em 73,3% (11/15, 80% (12/15 e 60% (3/5 dos estudos que analisaram tais marcadores, respectivamente. Crianças com excesso de massa corporal possuem concentrações elevadas de IL-6, TNF-α e MCP-1 resultando em inflamação sistêmica crônica e aumentando o risco de desenvolvimento de outras doenças cardiovasculares. 

  3. Effect of Ethylene and 1-Methylcyclopropene (1-MCP) on color and Firmness of Red and Breaker Stage Tomato Stored at Different Temperatures

    NARCIS (Netherlands)

    Tadesse, T.N.; Farneti, B.; Woltering, E.J.

    2012-01-01

    The red color of the tomato fruit during ripening is due to the presence lycopene, a compound known for its antioxidant property. This compound is influenced by temperature, ethylene and 1-Methylcyclopropene (1-MCP) treatment. It was believed that ethylene application at chilling temperature could h

  4. 1-methylcyclopropene (1-MCP)-induced alteration in leaf photosynthetic rate, chlorophyll fluorescence, respiration and membrane damage in rice (Oryza sativa L.) under high night temperature

    Science.gov (United States)

    High night temperature (HNT) can induce ethylene-triggered reactive oxygen species production, which can cause premature leaf senescence and membrane damage, thereby affecting production, consumption and transfer of photosynthates, and yield. The 1-methylcyclopropene (1-MCP) can competitively bind w...

  5. Chemokine MCP1/CCL2 and RANTES/CCL5 gene polymorphisms influence Henoch–Schönlein purpura susceptibility and severity

    Directory of Open Access Journals (Sweden)

    Hsin-Hui Yu

    2015-04-01

    Conclusion: Our results support the fact that chemokines play important roles in the pathogenesis of HSP. MCP1/CCL2 gene polymorphisms were associated with susceptibility for HSP. RANTES/CCL5 gene polymorphisms may be related to disease severity and HSP nephritis.

  6. Effect of Ethylene and 1-Methylcyclopropene (1-MCP) on color and Firmness of Red and Breaker Stage Tomato Stored at Different Temperatures

    NARCIS (Netherlands)

    Tadesse, T.N.; Farneti, B.; Woltering, E.J.

    2012-01-01

    The red color of the tomato fruit during ripening is due to the presence lycopene, a compound known for its antioxidant property. This compound is influenced by temperature, ethylene and 1-Methylcyclopropene (1-MCP) treatment. It was believed that ethylene application at chilling temperature could

  7. Pilot Production of Large Area Microchannel Plates and Picosecond Photodetectors

    Science.gov (United States)

    Minot, M.; Adams, B.; Abiles, M.; Bond, J.; Craven, C.; Cremer, T.; Foley, M.; Lyashenko, A.; Popecki, M.; Stochaj, M.; Worstell, W.; Elam, J.; Mane, A.; Siegmund, O.; Ertley, C.

    2016-09-01

    Pilot production performance is reported for large area atomic layer deposition (ALD) coated microchannel plates (ALD-GCA-MCPs) and for Large Area Picosecond Photodetectors (LAPPD™) which incorporate them. "Hollowcore" glass capillary array (GCA) substrates are coated with ALD resistive and emissive layers to form the ALDGCA- MCPs, an approach that facilitates independent selection of glass substrates that are mechanically stronger and that have lower levels of radioactive alkali elements compared to conventional MCP lead glass, reducing background noise[1,2,3,4]. ALD-GCA-MCPs have competitive gain ( 104 each or 107 for a chevron pair ), enhanced lifetime and gain stability (7 C cm-2 of charge extraction), reduced background levels (0.028 events cm-2 sec-1) and low gamma-ray detection efficiency. They can be fabricated in large area (20cm X 20 cm) planar and curved formats suitable for use in high radiation environment applications, including astronomy, space instrumentation, and remote night time sensing. The LAPPD™ photodetector incorporates these ALD-GCA-MCPs in an all-glass hermetic package with top and bottom plates and sidewalls made of borosilicate float glass. Signals are generated by a bi-alkali Na2KSb photocathode, amplified with a stacked chevron pair of ALD-GCA-MCPs. Signals are collected on RF strip-line anodes integrated into to the bottom plates which exit the detector via pin-free hermetic seals under the side walls [5]. Tests show that LAPPDTMs have electron gains greater than 107, submillimeter spatial resolution for large (multiphoton) pulses and several mm for single photons, time resolution less than 50 picoseconds for single photons, predicted resolution less than 5 picoseconds for large pulses, high stability versus charge extraction[6], and good uniformity for applications including astrophysics, neutron detection, high energy physics Cherenkov light detection, and quantum-optical photon-correlation experiments.

  8. Controlling Laminate Plate Elastic Behavior

    OpenAIRE

    Mareš, T.

    2004-01-01

    This paper aims to express the relation of a measure of laminate plate stiffness with respect to the fiber orientation of its plies. The inverse of the scalar product of the lateral displacement of the central plane and lateral loading of the plate is the measure of laminate plate stiffness. In the case of a simply supported rectangular laminate plate this measure of stiffness is maximized, and the optimum orientation of its plies is searched.

  9. Microchannel plate streak camera

    Science.gov (United States)

    Wang, Ching L.

    1989-01-01

    An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras. The improved streak camera is far more sensitive to photons (UV to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1000 KeV x-rays.

  10. Electronic Equipment Cold Plates

    Science.gov (United States)

    1976-04-01

    equations for such a flow regiae. For laainar flow and Moderate teaperature differwwe« between the well «nd coolant, a aodifled Sieder -Tate...con- figuration. The heat-transfer coefficients, therefore, were determined by using both the Sieder -Tate and McAdams equations and the coaputed...values used In the analytical predictions. As with th* previous cold Plates, the Sieder -Tate equation gave too low of values for the heat- transfer

  11. Elastic plate spallation

    Science.gov (United States)

    Oline, L.; Medaglia, J.

    1972-01-01

    The dynamic finite element method was used to investigate elastic stress waves in a plate. Strain displacement and stress strain relations are discussed along with the stiffness and mass matrix. The results of studying point load, and distributed load over small, intermediate, and large radii are reported. The derivation of finite element matrices, and the derivation of lumped and consistent matrices for one dimensional problems with Laplace transfer solutions are included. The computer program JMMSPALL is also included.

  12. Plate Tearing by a Cone

    DEFF Research Database (Denmark)

    Simonsen, Bo Cerup

    1997-01-01

    The present paper is concerned with steady-state plate tearing by a cone. This is a scenario where a cone is forced through a ductile metal plate with a constant lateral tip penetration in a motion in the plane of the plate. The considered process could be an idealisaton of the damage, which...

  13. Plate Tearing by a Cone

    DEFF Research Database (Denmark)

    Simonsen, Bo Cerup

    1998-01-01

    The present paper is concerned with steady-state plate tearing by a cone. This is a scenario where a cone is forced through a ductile metal plate with a constant lateral tip penetration in a motion in the plane of the plate. The considered process could be an idealisation of the damage, which...

  14. Co-Treatment of EFF and 1-MCP for Enhancing the Shelf-Life and Aroma Volatile Compounds of Oriental Sweet Melons (Cucumis melo var. makuwa Makino)

    Institute of Scientific and Technical Information of China (English)

    BAI Xiao-hang; TENG Lu-hua; LÜ De-qing; QI Hong-yan

    2014-01-01

    Compared to other melon types, oriental sweet melon (Cucumis melo var. makuwa Makino) is quite a different species with a shorter shelf-life due to its typical climacteric behavior and thin pericarp. The purpose of this experiment is to explore the effects of co-treatment of enhanced freshness formulation (EFF) and 1-methylcyclopropene (1-MCP) on physiological changes and the content of aroma volatile compounds introduced by them of two oriental sweet melon cultivars (Yumeiren and Tianbao) during storage. The melons were stored in incubators with temperature of 15°C and a relative humidity of 85%for 24 d during which fruit quality and related physiological index were measured. Compared to the control, both treatments delayed fruit weight loss rate and kept the fruit ifrmness, water content and soluble solids content. Ascorbate peroxidase (APX) and phenylalanine ammonia lyase (PAL) activities showed lfuctuations in treated melons, while lipoxygenase (LOX) activity (P<0.01) and malondialdehyde (MDA) content (P<0.05) decreased compared to control. During the early stage of storage, alcohols and aldehydes were the main volatile compounds, and esters gradually increased during storage. Of all the esters, acetic esters were the main components, followed by oxalic acid esters and other esters. The total content of aroma volatile compounds, esters, alcohols and aldehydes of co-treated melons were all higher than those of 1-MCP treated and control melons. In addition, the aroma volatile peak of co-treated melons occurred later than that of 1-MCP treated and control melons. In summary, co-treatment of EFF and 1-MCP was more beneifcial than 1-MCP treatment to delay ripening and senescence, maintain fruit quality, enhance shelf-life and improve levels of aroma volatile compounds.

  15. Allelic frequency of the MCP-1 promoter -2518 polymorphism in the Turkish population and in Turkish patients with juvenile rheumatoid arthritis.

    Science.gov (United States)

    Ozyürek, A Ruhi; Gürses, Dolunay; Ulger, Zülal; Levent, Ertürk; Bakiler, A Rahmi; Berdeli, Afig

    2007-04-01

    Although genetic and environmental factors contribute to the pathogenesis of juvenile rheumathoid arthritis (JRA), the etiology and pathogenesis remain controversial. The objective of this study was to investigate genotypic and allelic frequencies of monocyte chemoattractant protein-1 (MCP-1) gene -2518 (G/A) polymorphism in the healthy Turkish population and patients with JRA. Genomic DNA was collected from 66 JRA patients and 150 healthy individuals. To evaluate the association of the -2518 (G/A) MCP-1 gene polymorphism with the outcome of JRA, we analyzed the types of JRA and the score on the childhood health assessment questionnaire (C-HAQ score). In the healthy Turkish population, the frequencies of A and G alleles were 71 and 29%, respectively. No significant difference was observed between the JRA patients and healthy subjects in the distribution allelic and genotypic frequencies of the -2518 (G/A) MCP-1 gene polymorphism (p>0.05). However, the AG genotype was found to be higher and the AA genotype was found to be lower in the patients with systemic type JRA compared to those with the other types of JRA (p=0.019). When the JRA patients were evaluated according to the C-HAQ score, we found that the -2518 (G/A) MCP-1 gene polymorphism did not relate the prognosis (p>0.05). AG genotype was found to be higher in the systemic type of JRA. The results indicate that MCP-1 gene polymorphism might slightly associate with patients with systemic JRA. Further studies are needed to elucidate the role of this polymorphism in the pathogenesis of JRA in various populations because this polymorphism has a functional significance and an ethnic difference.

  16. Leflunomide对实验性IgA肾病大鼠肾脏TGF -β1、MCP-1表达的影响%Effects of leflunomide on TGF-β1, MCP-1 expression in renal tissue in a rat experimental IgA nephropathy model

    Institute of Scientific and Technical Information of China (English)

    汤颖; 娄探奇; 成彩联; 游宇平; 冯智英

    2007-01-01

    目的:分别从基因和蛋白水平研究leflunomide对实验性IgA肾病(IgAN)大鼠肾组织转化生长因子(TGF-β1)、单核细胞趋化因子(MCP-1)水平的影响,了解其作用机制.方法:建立IgAN大鼠模型,随机分成leflunomide组、强的松组、模型对照组,并同时设立正常对照组.用免疫组化、RT-PCR的方法分别检测和比较各组肾组织TGF-β1、MCP-1蛋白和基因的表达水平.结果:Leflunomide组TGF-β1、MCP-1表达均明显低于模型对照组(P<0.05);leflunomide组与激素组相比,TGF-β1、MCP-1表达无明显差异.结论:Leflunomide可通过下调TGF-β1、MCP-1在肾脏的表达,减少局部炎症反应,延缓肾脏纤维化的进程,从而保护肾脏.

  17. Control of Titanium Alloy Thin Plate Welding Distortion by Trailing Peening

    Institute of Scientific and Technical Information of China (English)

    Xuesong LIU; Hongyuan FANG; Shude JI; Zhibo DONG

    2003-01-01

    The technology of trailing peening is a kind of promisingly bran-new technology which can be used to control weldingstress and distortion of Ti alloy thin plate. Control of TC4 Ti alloy thn plate welding stress and distortion underthe condition of convent

  18. Virtual instrument for monitoring process of brush plating

    Institute of Scientific and Technical Information of China (English)

    JING Xue-dong; XU Bin-shi; WANG Cheng-tao; ZHU Sheng; DONG Shi-yun

    2004-01-01

    A virtual instrument(Ⅵ) was developed to monitor the technological parameters in the process of brush plating, including coating thickness, brush-plating current, current density, deposition rate, and brush plating voltage. Meanwhile two approaches were presented to improve the measurement accuracy of coating thickness. One of them aims at eliminating the random interferences by moving average filtering; while the other manages to calculate the quantity of electricity consumed accurately with rectangular integration. With these two approaches, the coating thickness can be measured in real time with higher accuracy than the voltage-frequency conversion method. During the process of plating all the technological parameters are displayed visually on the front panel of the Ⅵ. Once brush current or current density overruns the limited values, or when the coating thickness reaches the objective value, the virtual will alarm. With this Ⅵ, the solution consumption can be decreased and the operating efficiency is improved.

  19. Development of high efficiency collector plates. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Santala, T.; Sabol, R.

    1976-02-01

    Composite metal technology was used to manufacture intermetallic compound (IC) absorption surfaces and to combine them integrally with composite metal tube-in-sheet collector plates. Five material systems in which Al was one component metal and Fe, Cr, or Ni and their alloy was the other pair, were evaluated. All intermetallic compounds had high solar absorptance ..cap alpha.. approx. = 0.9. The AlNi was most promising and ..cap alpha.. > or = 0.95 and epsilon approx. = 0.3 were obtained over a broad range of compounding conditions. After eight months exposure in a flat plate collector enclosure the characteristic properties of AlNi surfaces remained virtually unchanged. Only LCS/Cu composite metal tube-in-sheet collector plates could be manufactured successfully. The technical difficulties associated with integrating the intermetallic compound and tube-in-sheet technologies make the manufacturing of composite metal collector plates at the time being economically unfeasible.

  20. Plate tectonics conserves angular momentum

    Directory of Open Access Journals (Sweden)

    C. Bowin

    2009-03-01

    Full Text Available A new combined understanding of plate tectonics, Earth internal structure, and the role of impulse in deformation of the Earth's crust is presented. Plate accelerations and decelerations have been revealed by iterative filtering of the quaternion history for the Euler poles that define absolute plate motion history for the past 68 million years, and provide an unprecedented precision for plate angular rotation variations with time at 2-million year intervals. Stage poles represent the angular rotation of a plate's motion between adjacent Euler poles, and from which the maximum velocity vector for a plate can be determined. The consistent maximum velocity variations, in turn, yield consistent estimates of plate accelerations and decelerations. The fact that the Pacific plate was shown to accelerate and decelerate, implied that conservation of plate tectonic angular momentum must be globally conserved, and that is confirmed by the results shown here (total angular momentum ~1.4 E+27 kgm2s−1. Accordingly, if a plate decelerates, other plates must increase their angular momentums to compensate. In addition, the azimuth of the maximum velocity vectors yields clues as to why the "bend" in the Emperor-Hawaiian seamount trend occurred near 46 Myr. This report summarizes processing results for 12 of the 14 major tectonic plates of the Earth (except for the Juan de Fuca and Philippine plates. Plate accelerations support the contention that plate tectonics is a product of torques that most likely are sustained by the sinking of positive density anomalies due to phase changes in subducted gabbroic lithosphere at depth in the upper lower mantle (above 1200 km depth. The tectonic plates are pulled along by the sinking of these positive mass anomalies, rather than moving at near constant velocity on the crests of convection cells driven by rising heat. These results imply that spreading centers are primarily passive reactive

  1. Vehicle License Plate Recognition Syst

    Directory of Open Access Journals (Sweden)

    Meenakshi,R. B. Dubey

    2012-12-01

    Full Text Available The vehicle license plate recognition system has greater efficiency for vehicle monitoring in automatic zone access control. This Plate recognition system will avoid special tags, since all vehicles possess a unique registration number plate. A number of techniques have been used for car plate characters recognition. This system uses neural network character recognition and pattern matching of characters as two character recognition techniques. In this approach multilayer feed-forward back-propagation algorithm is used. The performance of the proposed algorithm has been tested on several car plates and provides very satisfactory results.

  2. Using plate mapping to examine portion size and plate composition for large and small divided plates.

    Science.gov (United States)

    Sharp, David E; Sobal, Jeffery; Wansink, Brian

    2014-12-01

    Does the size of a plate influence the serving of all items equally, or does it influence the serving of some foods - such as meat versus vegetables - differently? To examine this question, we used the new method of plate mapping, where people drew a meal on a paper plate to examine sensitivity to small versus large three-compartment divided plates in portion size and meal composition in a sample of 109 university students. The total drawn meal area was 37% bigger on large plates than small plates, which showed that the portion of plate coverage did not differ by plate size. Men and women drew bigger vegetable portions and men drew bigger meat portions on large plates when compared to small plates. These results suggest that men and women are differentially sensitive to plate size for overall meal size and for meal composition. Implications for decreasing portion size and improving meal balance are that plate size may influence portion size and change the proportions of foods served.

  3. 基于高光谱技术的培养基上细菌菌落分类方法研究%Classification of Bacterial Colonies on Agar Plates Using Hyperspectral Imaging Technology

    Institute of Scientific and Technical Information of China (English)

    余伟; 彭宽宽; 陈伟; 穆渴心; 谭臣; 王湘如; 冯耀泽

    2016-01-01

    利用高光谱技术对培养基上细菌(大肠杆菌、李斯特菌和金黄色葡萄球菌)菌落进行快速识别和分类。采集琼脂培养基上细菌菌落的高光谱反射图像(390~1040 nm),在对波段差图像进行大津阈值分割的基础上自动提取细菌菌落光谱,并建立细菌分类检测的全波长和简化偏最小二乘判别( PLS-DA)模型。全波长模型对预测集样本的分类准确率和置信预测分类准确率分别为100%和95.9%。此外,利用竞争性自适应重加权算法( CARS)、遗传算法( GA)和最小角回归算法( LARS-Lasso)进行波长优选并建立对应简化模型。其中,CARS简化模型在精度、稳定性及分类准确率方面均优于GA和LARS-Lasso简化模型,其对预测集样本的分类准确率和置信预测分类准确率分别达到了100%和98.0%。研究表明,高光谱是一种细菌菌落高精度、快速、无损识别检测的有效方法。简化模型中优选的波长可以为开发低成本检测仪器提供理论依据。%Rapid detection and classification of bacteria colonies ( Escherichia coli, Listeria monocytogens and Staphylococcus aureus) were investigated by using hyperspectral imaging. The hyperspectral reflectance images (390-1040 nm ) of bacterial colonies on agar plates were collected. Bacterial spectra were extracted automatically based on the masks produced by segmenting a band difference image using the OTSU method. Full wavelength and simplified PLS-DA models were established for classification of bacterial colonies. For the full wavelength model, the overall correct classification rate ( OCCR) and confident OCCR for the prediction set were 100% and 95. 9%, respectively. Besides, competitive adaptive reweighted sampling ( CARS), genetic algorithm ( GA ) and least angle regression-least absolute shrinkage and selection operator ( LARS-Lasso) were used to select feature wavelengths for the development of simplified models. Among them, the CARS

  4. Development of microtitre plates for electrokinetic assays

    Science.gov (United States)

    Burt, J. P. H.; Goater, A. D.; Menachery, A.; Pethig, R.; Rizvi, N. H.

    2007-02-01

    Electrokinetic processes have wide ranging applications in microsystems technology. Their optimum performance at micro and nano dimensions allows their use both as characterization and diagnostic tools and as a means of general particle manipulation. Within analytical studies, measurement of the electrokinesis of biological cells has the sensitivity and selectivity to distinguish subtle differences between cell types and cells undergoing changes and is gaining acceptance as a diagnostic tool in high throughput screening for drug discovery applications. In this work the development and manufacture of an electrokinetic-based microtitre plate is described. The plate is intended to be compatible with automated sample loading and handling systems. Manufacturing of the microtitre plate, which employs indium tin oxide microelectrodes, has been entirely undertaken using excimer and ultra-fast pulsed laser micromachining due to its flexibility in materials processing and accuracy in microstructuring. Laser micromachining has the ability to rapidly realize iterations in device prototype design while also having the capability to be scaled up for large scale manufacture. Device verification is achieved by the measurement of the electrorotation and dielectrophoretic properties of yeast cells while the flexibility of the developed microtitre plate is demonstrated by the selective separation of live yeast from polystyrene microbeads.

  5. Slab Tracking and Controlling on Hot Plate Rolling Line

    Institute of Scientific and Technical Information of China (English)

    姚小兰; 邓波; 梁启宏; 李保奎

    2004-01-01

    By studying the slab moving in detail in the plate rolling process, the problem of slab tracking and controlling was solved by using the distributed control system. The problems of rhythm control for the big-complex system, the exchange of manual and automatic operations, the data exchange between the levelⅠ, TCS (technology control system) and levelⅡ, PCS (process control system), are solved. By this way, the automatic level of the plate production line is improved.

  6. Temperature field of steel plate cooling process after plate rolling

    Directory of Open Access Journals (Sweden)

    Huijun Feng, Lingen Chen, Fengrui Sun

    2015-01-01

    Full Text Available Based on numerical calculation with Matlab, the study on cooling process after plate rolling is carried out, and the temperature field distribution of the plate varying with the time is obtained. The effects of the plate thickness, final rolling temperature, cooling water temperature, average flow rate of the cooling water, carbon content of the plate and cooling method on the plate surface and central temperatures as well as final cooling temperature are discussed. For the same cooling time, the plate surface and central temperatures as well as their temperature difference increase; with the decrease in rolling temperature and the increase in average flow rate of the cooling water, the plate surface and central temperatures decrease. Compared with the single water cooling process, the temperature difference between the plate centre and surface based on intermittent cooling is lower. In this case, the temperature uniformity of the plate is better, and the corresponding thermal stress is lower. The fitting equation of the final cooling temperature with respect to plate thickness, final rolling temperature, cooling water temperature and average flow rate of the cooling water is obtained.

  7. 山茱萸新苷对EAE中枢神经系统MCP-1表达及CD68阳性细胞浸润的影响%The Impact of Cornuside on the Expression of MCP-1 and the Infiltration of CD68 Positive Cells in the Central Nervous System in EAE

    Institute of Scientific and Technical Information of China (English)

    张荣博; 徐彬; 朱敏姿; 周未莹; 吴忧; 梁顺利; 章水晶; 李铮; 袁强

    2016-01-01

    [目的]研究山茱萸新苷对实验性自身免疫性脑脊髓炎( experimental autoimmune encephalomyelitis, EAE)大鼠中枢神经系统单核细胞趋化蛋白-1( monocyte chemoattractant protein-1,MCP-1)表达及CD68阳性细胞浸润的影响。[方法]制备豚鼠全脊髓匀浆免疫抗原,皮下注射至 Lewis大鼠,建立EAE模型。设正常对照组、EAE组、山茱萸新苷组、波尼松组,每天神经功能评分,待症状达到高峰处死实验动物,用RT-PCR、Western Blot法比较各组实验动物中枢神经系统MCP-1 mRNA及蛋白的表达,免疫组织化学染色法比较各组实验动物中枢神经系统 CD68阳性细胞浸润情况。[结果]正常对照组、EAE组、山茱萸新苷组、波尼松组大鼠MCP-1 mRNA的相对表达量分别为(11.265±2.928)、(401.373±55.398)、(124.987±20.244)、(75.465±7.766),MCP-1蛋白相对表达量分别为(7.458±2.570)、(24.155±1.420)、(19.568±0.863)、(17.458±1.630),CD68阳性指数分别为0%、(41.93±12.25)%、(16.08±8.70)%、(5.38±2.88)%。使用单因素方差分析法,MCP-1 mRNA的相对表达量、MCP-1蛋白相对表达量、CD68阳性指数组间差异显著,均有统计学意义( F=199.734、66.081、35.565,均P=0.000)。山茱萸新苷组与EAE组在神经功能评分、MCP-1 mRNA的相对表达量、MCP-1蛋白相对表达量、CD68阳性指数表达差异均有统计学意义( P=0.002、0.000、0.003、0.013)。[结论]山茱萸新苷可改善 EAE大鼠神经功能,抑制EAE大鼠中枢神经系统MCP-1表达及CD68阳性细胞浸润。%Objective] To explore the impact of cornuside on the expression of MCP-1 and the infiltration of CD68 positive cells in the central nervous system in EAE. [Methods] An EAE model was established by injecting the guinea pig spinal cord homogenate antigen in subcutaneous tissue of Lewis rats. The rats were randomly divided into normal control group, EAE

  8. Real Plates and Dubious Microplates

    Science.gov (United States)

    Kogan, M. G.; Steblov, G. M.

    2008-12-01

    From the onset of plate tectonics, the existence of most of the plates was never put in doubt, although the boundaries of some plates, like Africa, were later revised. There are however, two microplates in northeast Asia, the Amurian and Okhotsk, whose existence and the sense of rotation was revised several times. The rms value of plate-residual GPS velocities is 0.5-0.9 mm/a for sets of stations representing the motion of the following plates: Antarctic, Australian, Eurasian, North American, Nubian, Pacific, and South American. This value can be regarded as an upper bound on deviation of real plates from infinite stiffness. The rms value of plate-residual GPS velocities is 1.2-1.8 mm/a for the Indian, Nazca, and Somalian plates. Higher rms values for India and Nazca are attributed to the noisier data. The higher rms value for Somalia appears to arise from the distributed deformation to the east of the East African Rift; whether this statement is true can only be decided from observations of denser network in the future. From the analysis of plate-residual GPS velocities, the Canadian Arctic and northeastern Siberia belong to the North American plate. The detailed GPS survey on Sakhalin Island shows that the Sea of Okhotsk region also belongs to the North American plate while the region to the west of it belongs to the Eurasian plate. These results provide a constraint on the geometry of the North American plate and put in doubt the existence of smaller plates in northeast Asia.

  9. Parenteral iron formulations differentially affect MCP-1, HO-1, and NGAL gene expression and renal responses to injury.

    Science.gov (United States)

    Johnson, Ali C M; Becker, Kirsten; Zager, Richard A

    2010-08-01

    Despite their prooxidant effects, ferric iron compounds are routinely administered to patients with renal disease to correct Fe deficiency. This study assessed relative degrees to which three clinically employed Fe formulations [Fe sucrose (FeS); Fe gluconate (FeG); ferumoxytol (FMX)] impact renal redox- sensitive signaling, cytotoxicity, and responses to superimposed stress [endotoxin; glycerol-induced acute renal failure (ARF)]. Cultured human proximal tubule (HK-2) cells, isolated proximal tubule segments (PTS), or mice were exposed to variable, but equal, amounts of FeS, FeG, or FMX. Oxidant-stimulated signaling was assessed by heme oxygenase-1 (HO-1) or monocyte chemoattractant protein (MCP)-1 mRNA induction. Cell injury was gauged by MTT assay (HK-2 cells), %LDH release (PTS), or renal cortical neutrophil gelatinase-associated lipoprotein (NGAL) protein/mRNA levels. Endotoxin sensitivity and ARF severity were assessed by TNF-alpha and blood urea nitrogen concentrations, respectively. FeS and FeG induced lethal cell injury (in HK-2 cells, PTS), increased HO-1 and MCP-1 mRNAs (HK-2 cells; in vivo), and markedly raised plasma ( approximately 10 times), and renal cortical ( approximately 3 times) NGAL protein levels. Both renal and extrarenal (e.g., hepatic) NGAL production likely contributed to these results, based on assessments of tissue and HK-2 cell NGAL mRNA. FeS pretreatment exacerbated endotoxemia. However, it conferred marked protection against the glycerol model of ARF (halving azotemia). FMX appeared to be "bioneutral," as it exerted none of the above noted FeS/FeG effects. We conclude that 1) parenteral iron formulations that stimulate redox signaling can evoke cyto/nephrotoxicity; 2) secondary adaptive responses to this injury (e.g., HO-1/NGAL induction) can initiate a renal tubular cytoresistant state; this suggests a potential new clinical application for intravenous Fe therapy; and 3) FMX is bioneutral regarding these responses. The clinical

  10. Meta-analysis on the association between MCP-1/CCR2 genes polymorphisms and coronary artery disease%MCP-1/CCR2基因多态性与冠状动脉疾病关联性的Meta分析

    Institute of Scientific and Technical Information of China (English)

    朱军; 蒯正平; 严建军; 王泽穆; 唐建金; 杨志健; 王连生

    2011-01-01

    目的:采用Meta分析探讨单核细胞趋化蛋白-1(monocyte chemotactic protein-1,MCP-1)基因的G2518A位点及趋化因子受体2(CC chemokine receptor 2,CCR2)基因的G190A位点多态性与冠状动脉疾病(coronary artery disease,CAD)的关联性.方法:通过PubMed,EMbase,CNKI及CBM等数据库搜索关于MCP-1/CCR2基因多态性与CAD关联性的文章.结果:符合纳入标准的共有21篇文献,MCP-1基因的G2518A位点和CCR2基因的G190A位点分别有6 835例CAD患者、11 142例正常对照受试者,以及2 801例CAD患者、5 789例正常对照受试者入选.综合数据表明MCP-1基因的G2518A位点和CCR2基因G190A位点多态性与CAD的发生存在关联[G2518A(P=0.04),G190A(P=0.005)].根据分层分析观察到MCP-1基因的G2518A位点在非亚洲人群中与CAD存在关联性(P=0.04),而在亚洲人群中与CAD不具有统计学意义(P>0.05).结论:MCP-1基因的G2518A位点及CCR2基因的G190A位点多态性与CAD的发生具有统计学意义.%Objective;To assess the association of monocyte chemotactic protein-1 (MCP-l)gene G2518A and CC chemokine receptor 2(CCR2) gene G190A polymorphisms with coronary artery disea9e(CAD). Methods:Databases, including PubMed, Embase, CNKI and CBM, were searched to get the association studies on MCP-1/CCR2,RANTES/CCR5 genes polymorphisms and CAD. Results: A total of 21 case-control studies were identified. The Meta-analysis included 6 835(MCP-1-G2518A) CAD case and 11 142 controls,2 801 CAD cases and 5 789 controls(CCR2-G190A),respectively. MCP-1 gene G2518A polymorphism was significantly associated with CAD(P = 0.04). The CCR2 gene G190A polymorphism was also significantly associated with the presence of CAD(P = 0.005). In stratified analysis by race, the MCP-1 gene G2518A polymorphism was significantly associated with the presence of CAD in non-Asian (P = 0.04), while not in Asian (P>0.05). Conclusion:Our results showed that the MCP-1 gene G2518A and CCR2 gene G190A polymorphisms were

  11. Correlation study on MCP-1, MMP-1 gene polymorphism and the incidence of tuberculosis in BCG-vaccinated individuals%卡介苗接种者MCP-1、MMP-1基因多态性与肺结核发病率的相关性研究

    Institute of Scientific and Technical Information of China (English)

    夏小学; 陈江; 张美禄; 沈志成; 余文菁; 卢火佺

    2013-01-01

    目的:探讨我国汉族人群单核细胞趋化蛋白-1(MCP-1)基因-2518位点、基质金属蛋白酶-1(MMP-1)基因-1607位点多态性与肺结核发病的相关性.方法:选择有卡介苗接种史的肺结核患者188例(TB组)与结核菌素皮试阳性的健康者194例(PPD+组).分析两组人群MCP-1-2518 A/G位点、MMP-1-1607 1G/2G位点基因型、等位基因频率及与肺结核发病的关系.结果:两组人群MCP-1-2518A/G位点、MMP-1-1607 1G/2G位点基因型、等位基因频率分布符合Hardy-Weinberg平衡定律.MCP-1-2518 G、MMP-1-1607 2G等位基因的频率分布与肺结核的发病有显著相关性(P<0.01),MCP-1-2518G/G、MMP-1-1607 2G/2G表型易患肺结核(P<0.05).结论:我国汉族人群MCP-1-2518 G/G表型、MMP-1-1607 2G/2G表型与肺结核的发生有显著相关性.%Objective:To investigate the correlation between monocyte chemoattractant protein-1 (MCP-1)gene-2518 loci,matrix metalloproteinase-1 (MMP-1) gene-1607 loci polymorphism and the incidence of tuberculosis in the Chinese Han population.Methods:One hundred and eighty-eight cases of tuberculosis patients (TB group) and 194 healthy volunteers with positive tuberculin skin test (PPD group) were selected as BCG-vaccinated individuals.The genotype and allele frequencies of MCP-1-2518 A/G locus,MMP-1-1607 1G/2G locus,and the relationship with the incidence of TB were analyzed.Results:The MCP-1-2518 A/G locus,MMP -1-1607 1G/2G locus,allele freauency distribution of the two groups conformed to Hardy-Weinberg equilibrium.The significant correlation was found MCP-1-2518 G,MMP-1-1607 2G allele frequency distribution and the incidence of TB (P <0.01),and MCP-1-2518 G/G,MMP-1-1607 2G/2G phenotype were susceptible to tuberculosis (P < 0.05).Conclusion:The MCP-1-2518 G/G,MMP-1-1607 2G/2G phenotype might be associated with susceptibility to tuberculosis in Chinese Han population.

  12. Plate Full of Color

    Centers for Disease Control (CDC) Podcasts

    2008-08-04

    The Eagle Books are a series of four books that are brought to life by wise animal characters - Mr. Eagle, Miss Rabbit, and Coyote - who engage Rain That Dances and his young friends in the joy of physical activity, eating healthy foods, and learning from their elders about health and diabetes prevention. Plate Full of Color teaches the value of eating a variety of colorful and healthy foods.  Created: 8/4/2008 by National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP).   Date Released: 8/5/2008.

  13. Dynamics of Tectonic Plates

    CERN Document Server

    Pechersky, E; Sadowski, G; Yambartsev, A

    2014-01-01

    We suggest a model that describes a mutual dynamic of tectonic plates. The dynamic is a sort of stick-slip one which is modeled by a Markov random process. The process defines a microlevel of the dynamic. A macrolevel is obtained by a scaling limit which leads to a system of integro-differential equations which determines a kind of mean field systems. Conditions when Gutenberg-Richter empirical law are presented on the mean field level. These conditions are rather universal and do not depend on features of resistant forces.

  14. Dynamics of Tectonic Plates

    OpenAIRE

    2014-01-01

    We suggest a model that describes a mutual dynamic of tectonic plates. The dynamic is a sort of stick-slip one which is modeled by a Markov random process. The process defines a microlevel of the dynamic. A macrolevel is obtained by a scaling limit which leads to a system of integro-differential equations which determines a kind of mean field systems. Conditions when Gutenberg-Richter empirical law are presented on the mean field level. These conditions are rather universal and do not depend ...

  15. The ACTS Flight System - Cost-Effective Advanced Communications Technology. [Advanced Communication Technology Satellite

    Science.gov (United States)

    Holmes, W. M., Jr.; Beck, G. A.

    1984-01-01

    The multibeam communications package (MCP) for the Advanced Communications Technology Satellite (ACTS) to be STS-launched by NASA in 1988 for experimental demonstration of satellite-switched TDMA (at 220 Mbit/sec) and baseband-processor signal routing (at 110 or 27.5 Mbit/sec) is characterized. The developmental history of the ACTS, the program definition, and the spacecraft-bus and MCP parameters are reviewed and illustrated with drawings, block diagrams, and maps of the coverage plan. Advanced features of the MPC include 4.5-dB-noise-figure 30-GHz FET amplifiers and 20-GHz TWTA transmitters which provide either 40-W or 8-W RF output, depending on rain conditions. The technologies being tested in ACTS can give frequency-reuse factors as high as 20, thus greatly expanding the orbit/spectrum resources available for U.S. communications use.

  16. Construction technology of soft foundation reinforcement with plastic drainage plates for Minjiang River flood dike%闽江防洪堤软土地基塑料排水板加固施工技术

    Institute of Scientific and Technical Information of China (English)

    周婉真

    2015-01-01

    The author discussed the engineering geological conditions of Fuzhou section(1st-stage)of Minjiang River Flood Protection Project and the working principle of soft foundation treatment with plastic drainage plates. An introduction was made on the material of plastic drainage plate, the construction machine, technical program, monitoring method and construction quality control measures.%论述了闽江防洪工程福州段(一期)工程的工程地质情况及塑料排水板处理软土地基的工作原理。介绍了塑料排水板的材料、施工机械、工艺流程、监测方法和施工质量控制措施。

  17. Research Progress on the Role of MCP-1/CCR2 Signaling Axis in the Development of Gastrointestinal Tumors%MCP-1/CCR2信号轴在消化系统肿瘤发生发展中的研究进展

    Institute of Scientific and Technical Information of China (English)

    刘天宇; 曹海龙; 王邦茂

    2016-01-01

    单核细胞趋化蛋白1(MCP-1)/CC 趋化因子受体2(CCR2)信号轴是指由趋化因子 MCP-1与其特异性受体 CCR2相互作用构成的一个与细胞间信息传递和细胞迁移有密切关系的耦联分子对,在肿瘤细胞以及肿瘤微环境中的多种细胞中表达,对肿瘤的发生发展起重要作用。在消化系统肿瘤发生发展过程中, MCP-1/CCR2信号轴的作用越来越受到国内外的关注,相关分子机制研究涉及肿瘤相关巨噬细胞的募集和极化,新生血管生成及异常免疫反应等,可为消化系统肿瘤防治提供新的思路。本文就近年来对 MCP-1/CCR2信号轴与消化系统肿瘤发生发展的研究进展进行综述。%Monocyte chemoattractant protein-1 (MCP-1) / CC chemokine receptor 2 (CCR2) signaling axis is defined as a coupled molecule that was made up by the interaction between chemokine MCP-1 and its specific receptor CCR2 and closely related to the intercellular information transmission and cell migration. MCP-1/CCR2 signal axis is expressed in tu-mor cells and a variety of cells in tumor microenvironment. It plays an important role in the development of tumor. Its role in the development of digestive system neoplasm received increasing attention from researchers in the world. The mechanisms involved the recruitment and polarization of tumor-associated macrophages, angiogenesis and abnormal immune response, etc. It would provide new ideas for the prevention and treatment of gastrointestinal tumors. The present article summarized the recent advances in the role of MCP-1/CCR2 signaling axis in the development of gastrointestinal tumors, and outlined the future prospect.

  18. A case-control association study between Obsessive-Compulsive Disorder (OCD and the MCP-1 -2518G/A polymorphism in a Chinese sample Estudo de associação de casos-controle entre Transtorno Obsessivo-Compulsivo (TOC e polimorfismo MCP-1 -2518G/A em uma coorte chinesa

    Directory of Open Access Journals (Sweden)

    Xinhua Zhang

    2012-12-01

    Full Text Available OBJECTIVE: To investigate the association between Obsessive-Compulsive Disorder (OCD and a functional polymorphism of MCP-1 in the Chinese Han population. METHOD: We genotyped and performed a case-control association analysis of the MCP-1 -2518G/A polymorphism in 200 OCD patients and 294 healthy control subjects. RESULTS: There was no significant difference in MCP-1 -2518G/A genotypic and allelic frequencies between OCD cases and controls (x² = 1.123, df = 2, P = 0.57 by genotype; x² = 0.802, df = 1, P = 0.37 by allele. CONCLUSIONS: Our results indicated that MCP-1 -2518G/A may not play a major role in the genetic predisposition of the Chinese Han population to OCD. However, further studies using a larger number of subjects are required to obtain a clear conclusion.OBJETIVO: Investigar a relação entre Transtorno Obsessivo-Compusilvo (TOC e um polimorfismo funcional de MCP-1 na população chinesa de etnia Han. MÉTODOS: Determinamos os genótipos e realizamos uma análise de associações de casos-controle de polimorfismo MCP-1 -2518G/A em 200 indivíduos com TOC e 294 indivíduos saudáveis (controle. RESULTADOS: Não houve diferença significativa no genótipo MCP-1 -2518G/A e nas frequências alélicas entre casos de TOC e controles (x² = 1,123, df = 2, P = 0,57 por genotipo; x² = 0,802, df = 1, P = 0,37 por alelo. CONCLUSÕES: Nossos resultados indicaram que MCP-1 -2518G/A pode não ter grande participação na predisposição genética da etnia Han no que diz respeito ao TOC. Contudo, novos estudos com um maior número de indivíduos são necessários para uma conclusão mais clara.

  19. Cigarette smoke-related hydroquinone dysregulates MCP-1, VEGF and PEDF expression in retinal pigment epithelium in vitro and in vivo.

    Directory of Open Access Journals (Sweden)

    Marianne Pons

    Full Text Available BACKGROUND: Age-related macular degeneration (AMD is the leading cause of legal blindness in the elderly population. Debris (termed drusen below the retinal pigment epithelium (RPE have been recognized as a risk factor for dry AMD and its progression to wet AMD, which is characterized by choroidal neovascularization (CNV. The underlying mechanism of how drusen might elicit CNV remains undefined. Cigarette smoking, oxidative damage to the RPE and inflammation are postulated to be involved in the pathophysiology of the disease. To better understand the cellular mechanism(s linking oxidative stress and inflammation to AMD, we examined the expression of pro-inflammatory monocyte chemoattractant protein-1 (MCP-1, pro-angiogenic vascular endothelial growth factor (VEGF and anti-angiogenic pigment epithelial derived factor (PEDF in RPE from smoker patients with AMD. We also evaluated the effects of hydroquinone (HQ, a major pro-oxidant in cigarette smoke on MCP-1, VEGF and PEDF expression in cultured ARPE-19 cells and RPE/choroids from C57BL/6 mice. PRINCIPAL FINDINGS: MCP-1, VEGF and PEDF expression was examined by real-time PCR, Western blot, and ELISA. Low levels of MCP-1 protein were detected in RPE from AMD smoker patients relative to controls. Both MCP-1 mRNA and protein were downregulated in ARPE-19 cells and RPE/choroids from C57BL/6 mice after 5 days and 3 weeks of exposure to HQ-induced oxidative injury. VEGF protein expression was increased and PEDF protein expression was decreased in RPE from smoker patients with AMD versus controls resulting in increased VEGF/PEDF ratio. Treatment with HQ for 5 days and 3 weeks increased the VEGF/PEDF ratio in vitro and in vivo. CONCLUSION: We propose that impaired RPE-derived MCP-1-mediated scavenging macrophages recruitment and phagocytosis might lead to incomplete clearance of proinflammatory debris and infiltration of proangiogenic macrophages which along with increased VEGF/PEDF ratio favoring

  20. Development of Catalytic Cooking Plates

    Energy Technology Data Exchange (ETDEWEB)

    Hjelm, Anna-Karin; Silversand, Fredrik [CATATOR AB, Lund (Sweden); Tena, Emmanuel; Berger, Marc [Gaz de France (France)

    2004-04-01

    Gas catalytic combustion for gas stoves or cooking plates (closed catalytic burner system with ceramic plates) is a very promising technique in terms of ease of cleaning, power modulation and emissions. Previous investigations show that wire mesh catalysts, prepared and supplied by Catator AB (CAT), seem to be very well suited for such applications. Beside significantly reducing the NOx-emissions, these catalysts offer important advantages such as good design flexibility, low pressure drop and high heat transfer capacity, where the latter leads to a quick thermal response. Prior to this project, Gaz de France (GdF) made a series of measurements with CAT's wire mesh catalysts in their gas cooking plates and compared the measured performance with similar results obtained with theirs cordierite monolith catalysts. Compared to the monolith catalyst, the wire mesh catalyst was found to enable very promising results with respect to both emission levels (<10 mg NO{sub x} /kWh, <5 mg CO/kWh) and life-time (>8000 h vs. 700 h at 200 kW/m{sup 2}). It was however established that the radiation and hence, the thermal efficiency of the cooking plate, was significantly less than is usually measured in combination with the monolith (15 % vs. 32 %). It was believed that the latter could be improved by developing new burner designs based on CAT's wire mesh concept. As a consequence, a collaboration project between GdF, CAT and the Swedish Gas Technology AB was created. This study reports on the design, the construction and the evaluation of new catalytic burners, based on CAT's wire mesh catalysts, used for the combustion of natural gas in gas cooking stoves. The evaluation of the burners was performed with respect to key factors such as thermal efficiency, emission quality and pressure drop, etc, by the use of theoretical simulations and experimental tests. Impacts of parameters such as the the wire mesh number, the wire mesh structure (planar or folded), the

  1. CMS Resistive plate Champers

    CERN Document Server

    Zainab, Karam

    2013-01-01

    There are many types of gas detectors which are used in CERN in LHC project, There is a main parts for the gas detectors which must be in all gas detectors types like Multiwire proportional chambers, such as the micromesh gaseous structure chamber (the MicroMegas), Gas-electron multiplier (GEM) detector, Resistive Plate Champers... Compact Muon Solenoid (CMS) experiment detecting muons which are powerful tool for recognizing signatures of interesting physics processes. The CMS detector uses: drift tube (DT), cathode strip chamber (CSC) and resistive plate chamber (RPC). Building RPC’s was my project in summer student program (hardware). RPC’s have advantages which are triggering detector and Excellent time resolution which reinforce the measurement of the correct beam crossing time. RPC’s Organized in stations :  RPC barrel (RB) there are 4 stations, namely RB1, RB2, RB3, and RB4  While in the RPC endcap (RE) the 3 stations are RE1, RE2, and RE3. In the endcaps a new starion will be added and this...

  2. Improved lifetime of microchannel-plate PMTs

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, A., E-mail: lehmann@physik.uni-erlangen.de [Physikalisches Institut IV, Friedrich Alexander-University of Erlangen-Nuremberg, Erlangen (Germany); Britting, A.; Eyrich, W.; Uhlig, F. [Physikalisches Institut IV, Friedrich Alexander-University of Erlangen-Nuremberg, Erlangen (Germany); Dzhygadlo, R.; Gerhardt, A.; Götzen, K.; Höhler, R.; Kalicy, G.; Kumawat, H.; Lehmann, D.; Lewandowski, B.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwarz, C.; Schwiening, J.; Traxler, M.; Zühlsdorf, M. [GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt (Germany); and others

    2014-12-01

    The charged particle identification at the PANDA experiment will be mainly performed with DIRC detectors. Because of their advantageous properties the preferred photon sensors are MCP-PMTs. However, until recently these devices showed serious aging problems which resulted in a diminishing quantum efficiency (QE) of the photo cathode. By applying innovative countermeasures against the aging causes, the manufacturers recently succeeded in drastically improving the lifetime of MCP-PMTs. Especially the application of an ALD coating technique to seal the material of the micro-channels proves very powerful and results in a lifetime of ≈6C/cm{sup 2} integrated anode charge without a substantial QE degradation for the latest PHOTONIS XP85112. This paper will present a comparative measurement of the lifetime of several older and recent MCP-PMTs demonstrating this progress.

  3. Improved lifetime of microchannel-plate PMTs

    Science.gov (United States)

    Lehmann, A.; Britting, A.; Eyrich, W.; Uhlig, F.; Dzhygadlo, R.; Gerhardt, A.; Götzen, K.; Höhler, R.; Kalicy, G.; Kumawat, H.; Lehmann, D.; Lewandowski, B.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwarz, C.; Schwiening, J.; Traxler, M.; Zühlsdorf, M.; Dodokhov, V. Kh.; Düren, M.; Föhl, K.; Hayrapetyan, A.; Kröck, B.; Merle, O.; Rieke, J.; Cowie, E.; Keri, T.; Montgomery, R.; Rosner, G.; Achenbach, P.; Cardinali, M.; Hoek, M.; Lauth, W.; Sfienti, C.; Thiel, M.; Bühler, P.; Gruber, L.; Marton, J.; Suzuki, K.

    2014-12-01

    The charged particle identification at the PANDA experiment will be mainly performed with DIRC detectors. Because of their advantageous properties the preferred photon sensors are MCP-PMTs. However, until recently these devices showed serious aging problems which resulted in a diminishing quantum efficiency (QE) of the photo cathode. By applying innovative countermeasures against the aging causes, the manufacturers recently succeeded in drastically improving the lifetime of MCP-PMTs. Especially the application of an ALD coating technique to seal the material of the micro-channels proves very powerful and results in a lifetime of ≈ 6 C /cm2 integrated anode charge without a substantial QE degradation for the latest PHOTONIS XP85112. This paper will present a comparative measurement of the lifetime of several older and recent MCP-PMTs demonstrating this progress.

  4. A corrosion resistant cerium oxide based coating on aluminum alloy 2024 prepared by brush plating

    Energy Technology Data Exchange (ETDEWEB)

    Tang Junlei; Han Zhongzhi [School of Materials Science and Engineering, Beijing University of Chemical Technology, Beijing 100029 (China); Zuo Yu, E-mail: zuoy@mail.buct.edu.cn [School of Materials Science and Engineering, Beijing University of Chemical Technology, Beijing 100029 (China); Tang Yuming [School of Materials Science and Engineering, Beijing University of Chemical Technology, Beijing 100029 (China)

    2011-01-15

    Cerium oxide based coatings were prepared on AA2024 Al alloy by brush plating. The characteristic of this technology is that hydrogen peroxide, which usually causes the plating solution to be unstable, is not necessary in the plating electrolyte. The coating showed laminated structures and good adhesive strength with the substrate. X-ray diffraction and X-ray photoelectron spectroscopy analysis showed that the coatings were composed of Ce(III) and Ce(IV) oxides. The brush plated coatings on Al alloys improved corrosion resistance. The influence of plating parameters on structure and corrosion resistance of the cerium oxide based coating was studied.

  5. Localised Plate Motion on Venus

    Science.gov (United States)

    Ghail, R. C.

    1996-03-01

    The volcanic and tectonic features observed in Dali Vinculum, Parga Vinculum and Imdr Regio are concentrated at long, narrow, curvilinear zones, with relatively minor volcanism and tectonism between these zones. These zones, whilst more diffuse than terrestrial plate boundaries, nevertheless define the margins of tectonic plates. In contrast to Earth, however, it appears that venusian plates are neither created nor destroyed by lateral motion. Rather, plates are thinned and intruded at vincula plate boundaries, vertically accreted by small-scale intra-plate (planitia) volcanism and perhaps destroyed by delamination of thickened crust in tesserae and montane regions such as Thetis Regio and Ishtar Terra. The diversity in age both between and within these three areas together with the evidence for infrequent, small scale resurfacing in the planitiae are difficult to reconcile with a non-uniformitarian geological process.

  6. Tectonics of the Easter plate

    Science.gov (United States)

    Engeln, J. F.; Stein, S.

    1984-01-01

    A new model for the Easter plate is presented in which rift propagation has resulted in the formation of a rigid plate between the propagating and dying ridges. The distribution of earthquakes, eleven new focal mechanisms, and existing bathymetric and magnetic data are used to describe the tectonics of this area. Both the Easter-Nazca and Easter-Pacific Euler poles are sufficiently close to the Easter plate to cause rapid changes in rates and directions of motion along the boundaries. The east and west boundaries are propagating and dying ridges; the southwest boundary is a slow-spreading ridge and the northern boundary is a complex zone of convergent and transform motion. The Easter plate may reflect the tectonics of rift propagation on a large scale, where rigid plate tectonics requires boundary reorientation. Simple schematic models to illustrate the general features and processes which occur at plates resulting from large-scale rift propagation are used.

  7. Tectonics of the Easter plate

    Science.gov (United States)

    Engeln, J. F.; Stein, S.

    1984-01-01

    A new model for the Easter plate is presented in which rift propagation has resulted in the formation of a rigid plate between the propagating and dying ridges. The distribution of earthquakes, eleven new focal mechanisms, and existing bathymetric and magnetic data are used to describe the tectonics of this area. Both the Easter-Nazca and Easter-Pacific Euler poles are sufficiently close to the Easter plate to cause rapid changes in rates and directions of motion along the boundaries. The east and west boundaries are propagating and dying ridges; the southwest boundary is a slow-spreading ridge and the northern boundary is a complex zone of convergent and transform motion. The Easter plate may reflect the tectonics of rift propagation on a large scale, where rigid plate tectonics requires boundary reorientation. Simple schematic models to illustrate the general features and processes which occur at plates resulting from large-scale rift propagation are used.

  8. Atomic layer deposition of alternative glass microchannel plates

    Energy Technology Data Exchange (ETDEWEB)

    O' Mahony, Aileen, E-mail: aom@incomusa.com; Craven, Christopher A.; Minot, Michael J.; Popecki, Mark A.; Renaud, Joseph M.; Bennis, Daniel C.; Bond, Justin L.; Stochaj, Michael E.; Foley, Michael R.; Adams, Bernhard W. [Incom, Inc., 294 Southbridge Road, Charlton, Massachusetts 01507 (United States); Mane, Anil U.; Elam, Jeffrey W. [Argonne National Laboratory, 9700 S. Cass Ave., Argonne, Illinois 60439 (United States); Ertley, Camden; Siegmund, Oswald H. W. [Space Sciences Laboratory, University of California, 7 Gauss Way, Berkeley, California 94720 (United States)

    2016-01-15

    The technique of atomic layer deposition (ALD) has enabled the development of alternative glass microchannel plates (MCPs) with independently tunable resistive and emissive layers, resulting in excellent thickness uniformity across the large area (20 × 20 cm), high aspect ratio (60:1 L/d) glass substrates. Furthermore, the use of ALD to deposit functional layers allows the optimal substrate material to be selected, such as borosilicate glass, which has many benefits compared to the lead-oxide glass used in conventional MCPs, including increased stability and lifetime, low background noise, mechanical robustness, and larger area (at present up to 400 cm{sup 2}). Resistively stable, high gain MCPs are demonstrated due to the deposition of uniform ALD resistive and emissive layers on alternative glass microcapillary substrates. The MCP performance characteristics reported include increased stability and lifetime, low background noise (0.04 events cm{sup −2} s{sup −1}), and low gain variation (±5%)

  9. Two-dimensional visualization of cluster beams by microchannel plates

    CERN Document Server

    Khoukaz, Alfons; Grieser, Silke; Hergemöller, Ann-Katrin; Köhler, Esperanza; Täschner, Alexander

    2013-01-01

    An advanced technique for a two-dimensional real time visualization of cluster beams in vacuum as well as of the overlap volume of cluster beams with particle accelerator beams is presented. The detection system consists of an array of microchannel plates (MCP) in combination with a phosphor screen which is read out by a CCD camera. This setup together with the ionization of a cluster beam by an electron or ion beam allows for spatial resolved investigations of the cluster beam position, size, and intensity. Moreover, since electrically uncharged clusters remain undetected, the operation in an internal beam experiment opens the way to monitor the overlap region and thus the position and size of an accelerator beam crossing an originally electrically neutral cluster jet. The observed intensity distribution of the recorded image is directly proportional to the convolution of the spatial ion beam and cluster beam intensities and is by this a direct measure of the two-dimensional luminosity distribution. This inf...

  10. Aluminum Manganese Molten Salt Plating

    Science.gov (United States)

    2006-06-01

    Dry fixture thoroughly with the air gun. Be especially careful to dry water out of crevices. Note: water is a contaminant to the plating process...easily destroyed if blown with the air. Be especially careful to dry water out of crevices. Note: water is a contaminant to the plating process and...especially careful to dry water out of crevices. 13. Carefully remove part from fixture. If residual plating solution is present at attachments points

  11. Induction of mitochondrial uncoupling enhances VEGF₁₂₀ but reduces MCP-1 release in mature 3T3-L1 adipocytes: possible regulatory mechanism through endogenous ER stress and AMPK-related pathways.

    Science.gov (United States)

    Miyokawa-Gorin, Kaoru; Takahashi, Kazuto; Handa, Keiko; Kitahara, Atsuko; Sumitani, Yoshikazu; Katsuta, Hidenori; Tanaka, Toshiaki; Nishida, Susumu; Yoshimoto, Katsuhiko; Ohno, Hideki; Ishida, Hitoshi

    2012-03-01

    Although white adipocytes contain a larger number of mitochondria per cytoplasmic volume, adipocyte mitochondrial uncoupling to reduce the efficiency of ATP production on cellular function including secretory regulation of bioactive molecules such as VEGF and MCP-1 remains to be elucidated. Here we induce mitochondrial uncoupling under hypoxia-independent conditions in mature 3T3-L1 adipocytes using a metabolic uncoupler, dinitrophenol (DNP). MCP-1 release was significantly decreased by 26% (poxidative stress was observed. Treatment with thapsigargin, which can induce exogenous endoplasmic reticulum (ER) stress, clearly attenuated MCP-1 release (pmetabolic syndrome and type 2 diabetes.

  12. Glass-bead peen plating

    Science.gov (United States)

    Graves, J. R.

    1974-01-01

    Peen plating of aluminum, copper, and nickel powders was investigated. Only aluminum was plated successfully within the range of peen plating conditions studied. Optimum plating conditions for aluminum were found to be: (1) bead/powder mixture containing 25 to 35% powder by weight, (2) peening intensity of 0.007A as measured by Almen strip, and (3) glass impact bead diameter of at least 297 microns (0.0117 inches) for depositing-100 mesh aluminum powder. No extensive cleaning or substrate preparation is required beyond removing loose dirt or heavy oil.

  13. Intermittent plate tectonics?

    Science.gov (United States)

    Silver, Paul G; Behn, Mark D

    2008-01-04

    Although it is commonly assumed that subduction has operated continuously on Earth without interruption, subduction zones are routinely terminated by ocean closure and supercontinent assembly. Under certain circumstances, this could lead to a dramatic loss of subduction, globally. Closure of a Pacific-type basin, for example, would eliminate most subduction, unless this loss were compensated for by comparable subduction initiation elsewhere. Given the evidence for Pacific-type closure in Earth's past, the absence of a direct mechanism for termination/initiation compensation, and recent data supporting a minimum in subduction flux in the Mesoproterozoic, we hypothesize that dramatic reductions or temporary cessations of subduction have occurred in Earth's history. Such deviations in the continuity of plate tectonics have important consequences for Earth's thermal and continental evolution.

  14. VISAS AND GREEN PLATES

    CERN Multimedia

    2000-01-01

    From 3 April 2000, all questions relating to visa requests for Switzerland, France, or Russia for a member of the personnel must be addressed to Ms. Agnita Querrou (telephone 72838, office 5-2-019, e-mail Agnita.Querrou@cern.ch).The Users' Office continues to deal with requests for letters of invitation and questions concerning visas for users in EP Division.Questions relating to removals, requests for green plates, to privileges of members of the personnel and to the importation of vehicles are still dealt with by Ms Zuzana Miller (telephone 79257, office 33-1-017, e-mail Zuzana.Muller@cern.ch) and Ms Joëlle Belleman (telephone 73962, office 33-1-019, e-mail Joelle.Belleman@cern.ch).

  15. The host response to the probiotic Escherichia coli strain Nissle 1917: Specific up-regulation of the proinflammatory chemokine MCP-1

    Directory of Open Access Journals (Sweden)

    Ukena Sya N

    2005-12-01

    Full Text Available Abstract Background The use of live microorganisms to influence positively the course of intestinal disorders such as infectious diarrhea or chronic inflammatory conditions has recently gained increasing interest as a therapeutic alternative. In vitro and in vivo investigations have demonstrated that probiotic-host eukaryotic cell interactions evoke a large number of responses potentially responsible for the effects of probiotics. The aim of this study was to improve our understanding of the E. coli Nissle 1917-host interaction by analyzing the gene expression pattern initiated by this probiotic in human intestinal epithelial cells. Methods Gene expression profiles of Caco-2 cells treated with E. coli Nissle 1917 were analyzed with microarrays. A second human intestinal cell line and also pieces of small intestine from BALB/c mice were used to confirm regulatory data of selected genes by real-time RT-PCR and cytometric bead array (CBA to detect secretion of corresponding proteins. Results Whole genome expression analysis revealed 126 genes specifically regulated after treatment of confluent Caco-2 cells with E. coli Nissle 1917. Among others, expression of genes encoding the proinflammatory molecules monocyte chemoattractant protein-1 ligand 2 (MCP-1, macrophage inflammatory protein-2 alpha (MIP-2α and macrophage inflammatory protein-2 beta (MIP-2β was increased up to 10 fold. Caco-2 cells cocultured with E. coli Nissle 1917 also secreted high amounts of MCP-1 protein. Elevated levels of MCP-1 and MIP-2α mRNA could be confirmed with Lovo cells. MCP-1 gene expression was also up-regulated in mouse intestinal tissue. Conclusion Thus, probiotic E. coli Nissle 1917 specifically upregulates expression of proinflammatory genes and proteins in human and mouse intestinal epithelial cells.

  16. PPAR agonist-induced reduction of Mcp1 in atherosclerotic plaques of obese, insulin-resistant mice depends on adiponectin-induced Irak3 expression.

    Directory of Open Access Journals (Sweden)

    Maarten Hulsmans

    Full Text Available Synthetic peroxisome proliferator-activated receptor (PPAR agonists are used to treat dyslipidemia and insulin resistance. In this study, we examined molecular mechanisms that explain differential effects of a PPARα agonist (fenofibrate and a PPARγ agonist (rosiglitazone on macrophages during obesity-induced atherogenesis. Twelve-week-old mice with combined leptin and LDL-receptor deficiency (DKO were treated with fenofibrate, rosiglitazone or placebo for 12 weeks. Only rosiglitazone improved adipocyte function, restored insulin sensitivity, and inhibited atherosclerosis by decreasing lipid-loaded macrophages. In addition, it increased interleukin-1 receptor-associated kinase-3 (Irak3 and decreased monocyte chemoattractant protein-1 (Mcp1 expressions, indicative of a switch from M1 to M2 macrophages. The differences between fenofibrate and rosiglitazone were independent of Pparγ expression. In bone marrow-derived macrophages (BMDM, we identified the rosiglitazone-associated increase in adiponectin as cause of the increase in Irak3. Interestingly, the deletion of Irak3 in BMDM (IRAK3(-/- BMDM resulted in activation of the canonical NFκB signaling pathway and increased Mcp1 protein secretion. Rosiglitazone could not decrease the elevated Mcp1 secretion in IRAK3(-/- BMDM directly and fenofibrate even increased the secretion, possibly due to increased mitochondrial reactive oxygen species production. Furthermore, aortic extracts of high-fat insulin-resistant LDL-receptor deficient mice, with lower adiponectin and Irak3 and higher Mcp1, showed accelerated atherosclerosis. In aggregate, our results emphasize an interaction between PPAR agonist-mediated increase in adiponectin and macrophage-associated Irak3 in the protection against atherosclerosis by PPAR agonists.

  17. Modulation of MCP-1, TGF-β1, and α-SMA Expressions in Granulation Tissue of Cutaneous Wounds Treated with Local Vitamin B Complex: An Experimental Study

    Directory of Open Access Journals (Sweden)

    Carla P. Martinelli-Kläy

    2014-11-01

    Full Text Available Vitamin B complex can modulate the inflammatory response and activate wound healing. However, the action mechanisms involved in this process are still unclear. The aim of this study was to evaluate the effects of vitamin B complex on the modulation of monocyte chemotactic protein (MCP-1, transforming growth factor (TGF-β1, and α-smooth muscle actin (α-SMA in granulation tissue growth. Cutaneous ulcers on Wistar rats were topically treated with vitamin B complex. MCP-1, TGF-β1, and α-SMA expressions were evaluated 24, 72, and 168 h after the treatment. Inflammatory cells were counted and collagen fibril staining was performed. After 24 h, more mononuclear cells (p ≤ 0.01 and a higher MCP-1 (p ≤ 0.05 and TGF-β1 (p ≤ 0.01 expression were observed. After 72 h, the number of fibroblasts and mononuclear cells (p ≤ 0.05 was elevated. After 168 h, an increased number of fibroblasts, myofibroblasts, and blood vessels (p ≤ 0.01 as well as a strong intensity of collagen fibril staining were seen. At that point, the cells presented a higher TGF-β1 expression (p ≤ 0.05, and the size of the ulcer area was decreased (p ≤ 0.01. We can conclude that vitamin B complex may stimulate a positive modulation of MCP-1, TGF-β1, and α-SMA expressions in granulation tissue of cutaneous ulcers. © 2014 S. Karger AG, Basel

  18. PPAR Agonist-Induced Reduction of Mcp1 in Atherosclerotic Plaques of Obese, Insulin-Resistant Mice Depends on Adiponectin-Induced Irak3 Expression

    Science.gov (United States)

    Arnould, Thierry; Tsatsanis, Christos; Holvoet, Paul

    2013-01-01

    Synthetic peroxisome proliferator-activated receptor (PPAR) agonists are used to treat dyslipidemia and insulin resistance. In this study, we examined molecular mechanisms that explain differential effects of a PPARα agonist (fenofibrate) and a PPARγ agonist (rosiglitazone) on macrophages during obesity-induced atherogenesis. Twelve-week-old mice with combined leptin and LDL-receptor deficiency (DKO) were treated with fenofibrate, rosiglitazone or placebo for 12 weeks. Only rosiglitazone improved adipocyte function, restored insulin sensitivity, and inhibited atherosclerosis by decreasing lipid-loaded macrophages. In addition, it increased interleukin-1 receptor-associated kinase-3 (Irak3) and decreased monocyte chemoattractant protein-1 (Mcp1) expressions, indicative of a switch from M1 to M2 macrophages. The differences between fenofibrate and rosiglitazone were independent of Pparγ expression. In bone marrow-derived macrophages (BMDM), we identified the rosiglitazone-associated increase in adiponectin as cause of the increase in Irak3. Interestingly, the deletion of Irak3 in BMDM (IRAK3−/− BMDM) resulted in activation of the canonical NFκB signaling pathway and increased Mcp1 protein secretion. Rosiglitazone could not decrease the elevated Mcp1 secretion in IRAK3−/− BMDM directly and fenofibrate even increased the secretion, possibly due to increased mitochondrial reactive oxygen species production. Furthermore, aortic extracts of high-fat insulin-resistant LDL-receptor deficient mice, with lower adiponectin and Irak3 and higher Mcp1, showed accelerated atherosclerosis. In aggregate, our results emphasize an interaction between PPAR agonist-mediated increase in adiponectin and macrophage-associated Irak3 in the protection against atherosclerosis by PPAR agonists. PMID:23620818

  19. Experimental Report for Thermal Hydraulic Behavior During Startup, Power Change and MCP Transient Operation by using the High Temperature/High Pressure Test Facility(VISTA)

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ki Yong; Park, Hyun Sik; Cho, Seok; Lee, Sung Jae; Choi, Nam Hyun; Min, Kyong Ho; Song, Chul Hwa; Park, Chun Kyong; Chung, Moon Ki

    2005-07-15

    The VISTA (Experimental Verification by Integral Simulation of Transients and Accidents) is an experimental facility to verify the performance and safety issues of the SMART-P (Pilot plant of the System-integrated Modular Advanced Reactor). The basic design of the SMART-P has been completed by KAERI. The present report describes experimental test results for performance test items, including heatup, power change, MCP transient, and natural circulation operations by using the VISTA facility.

  20. Effect of ARB on Expression of CD68 and MCP-1 in Adipose Tissue of Rats on Long-term High Fat Diet

    Institute of Scientific and Technical Information of China (English)

    Caihong GUO; Li YUAN; Xiaoling LIU; Aimin DU; Yan HUANG; Lili ZHANG

    2008-01-01

    In adipose tissue of rats on long-term high fat diet, the inflammatory changes the roles of angiotensin receptor blocker (ARB) in pimelitis and insulin resistance (IR) were observed. IR rat model was established by feeding high calorie and high fat diet. The change in insulin sensitivity was detected by euglycemic-hyperinsulinemic clamp technique 8 weeks after intervention by valsartan. The expression levels of CD68 and MCP-1 mRNA and proteins in adipose tissue were examined by RT-PCR and immunohistochemistry respectively. The parameters of blood glucose, insulin and blood lipid were analyzed. The results showed that in high fat diet group intra-abdominal obesity developed, the content of visceral fat and the number of inflammatory cells in local adipose tissue were significantly increased (p<0.01), the levels of serum triglyceride, free fatty acids and fasting serum insulin were markedly increased, the insulin sensitivity was significantly lowered (p<0.01), and the expression of CD68 and MCP-1 was significantly increased as compared with control group (P<0.01). In ARB interventional group, the content of visceral fat, the number of inflammatory cells and the expression of CD68 and MCP-1 in local adipose tissue were significantly reduced (all P<0.01), but the insulin sensitivity was significantly enhanced (P<0.01) as compared with high fat diet group. There were pimelitis and IR in rats with obesity induced by long-term high calorie and high fat diet. The ARB can significantly inhibit the infiltration of macrophages and the expression of MCP-1 in adipose tissue, thereby attenuating the inflammation and improving IR in rats.