WorldWideScience

Sample records for plate collector heat

  1. Annual measured and simulated thermal performance analysis of a hybrid solar district heating plant with flat plate collectors and parabolic trough collectors in series

    DEFF Research Database (Denmark)

    Tian, Zhiyong; Perers, Bengt; Furbo, Simon

    2017-01-01

    in large solar heating plants for a district heating network, a hybrid solar collector field with 5960 m2 flat plate collectors and 4039 m2 parabolic trough collectors in series was constructed in Taars, Denmark. The design principle is that the flat plate collectors preheat the return water from...... for this type of hybrid solar district heating plants with flat plate collectors and parabolic trough collectors in the Nordic region, but also introduce a novel design concept of solar district heating plants to other high solar radiation areas.......Flat plate collectors have relatively low efficiency at the typical supply temperatures of district heating networks (70–95 °C). Parabolic trough collectors retain their high efficiency at these temperatures. To maximize the advantages of flat plate collectors and parabolic trough collectors...

  2. A diagram for defined flat plate solar collector area for solar floor heating

    Energy Technology Data Exchange (ETDEWEB)

    Altuntop, N.; Tekin, Y. [Erciyes University, Dept. of Mechanical Engineering (Turkey); Cengel, Y.A. [Nevada Reno University, Dept. of Mechanical Engineering, NV (United States)

    2000-07-01

    In winters, one of the best ways to heat living areas by using the low- temperature - water obtained from flat-plate solar collectors is the floor heating. In floor heating, low temperature-water (30 + 60 deg C) can be used and heat can be stored in water when solar radiation is not possible. In this study, it is aimed to define collector surface needed to supply heat for floor heating. It is also aimed to define and explain the diagram developed for every heating months. The calculations about the sun geometry are used to define the amount of radiation coming in to the collectors. Formulations are made about the definition of solar radiation absorbed by the collectors, the total heat loss coefficient, and the collector plate surface temperature. These formulations are transformed in to the diagram. In addition, the studies, heat transfer calculations and design parameters about the floor of the heating areas are used. A combined collector floor heating diagram is obtained. This diagram is used to define collector surface area necessary to supply heat for floor heated places. In this diagram, the collector surface area is obtained by giving the heat capacity of the place area, floor surface temperature, approximate modulation distance of the floor, the elevation of city, collector slope angle, wind speed, sun shine lime and the amount of the solar radiation obtained from the solar radiation diagram. (authors)

  3. Theoretical investigation on thermal performance of heat pipe flat plate solar collector with cross flow heat exchanger

    Science.gov (United States)

    Xiao, Lan; Wu, Shuang-Ying; Zhang, Qiao-Ling; Li, You-Rong

    2012-07-01

    Based on the heat transfer characteristics of absorber plate and the heat transfer effectiveness-number of heat transfer unit method of heat exchanger, a new theoretical method of analyzing the thermal performance of heat pipe flat plate solar collector with cross flow heat exchanger has been put forward and validated by comparisons with the experimental and numerical results in pre-existing literature. The proposed theoretical method can be used to analyze and discuss the influence of relevant parameters on the thermal performance of heat pipe flat plate solar collector.

  4. Design, construction and testing of a liquid-heating flat-plate solar collector

    Energy Technology Data Exchange (ETDEWEB)

    Tuttle, R E

    1980-02-01

    The purpose of this study was to design, construct, and test a liquid-heating flat-plate solar collector. From the literature search, information was gathered concerning the basic components of the collector, the different processes and materials that can be used in the construction of these components, and their advantages and disadvantages. The literature search also revealed a method used to measure the performance of the collector in terms of efficiency and heat output. Design considerations were then listed for each of the major components as well as the collector as a single unit. Then, each component was designed, taking into consideration the final assembly of the completed unit. Detailed designs were required for the absorber plate and the box and frame assembly because of their complexity in construction and assembly. Once the components were designed, the construction details were arranged in a logical sequence, again considering the final assembly of the unit. The collector was then carefully constructed and assembled following the design details. After the solar collector was assembled completely, tests were made, data were obtained and recorded, and a collector performance curve was developed.

  5. Heat transfer and energy analysis of a solar air collector with smooth plate

    Science.gov (United States)

    Chabane, Foued; Moummi, Noureddine

    2014-04-01

    The heat transfer and thermal performance of a single pass solar air heater a smooth plate was investigated experimentally. In the present paper, energy and heat transfer analysis of a solar air collector with smooth plate, this technique is used to determine the optimal thermal performance of flat plate solar air heater by considering the different system and operating parameters to obtain maximum thermal performance. Thermal performance is obtained for different mass flow rate varying in the array 0.0108-0.0202 kg/s with five values, solar intensity; tilt angle and ambient temperature. We discuss the thermal behavior of this type of collector with new design and with my proper construction. An experimental study was carried out on a prototype installed on the experimental tests platform within the University of Biskra in the Algeria. The effects of air mass flow rate, emissivity of channel plates and wind heat transfer coefficient on the accuracy of the criterion are also investigated.

  6. Operational demonstration of a field of high performance flat plate collectors with isothermal heat transport

    Science.gov (United States)

    Merges, V.; Klippel, E.

    1983-12-01

    A solar plant with 21 sq m of highly efficient flat plate collectors and which requires no electricity is described. Heat transport is provided by saturated steam that condenses in a four cubic meter storage tank. The operation temperature is set by the buffer gas pressure between 100 and 140 C, and an absorption chiller is simulated as a heat consumer. The solar collectors were observed to exhibit high performance. Heat transport and temperature control offered high reliability and the thermal stratification in the tank was satisfactory. The positive result permits the design and construction of larger solar plants following the same technical principles.

  7. Heat transfer in a low latitude flat-plate solar collector

    Directory of Open Access Journals (Sweden)

    Oko C.O.C.

    2012-01-01

    Full Text Available Study of rate of heat transfer in a flat-plate solar collector is the main subject of this paper. Measurements of collector and working fluid temperatures were carried out for one year covering the harmattan and rainy seasons in Port Harcourt, Nigeria, which is situated at the latitude of 4.858oN and longitude of 8.372oE. Energy balance equations for heat exchanger were employed to develop a mathematical model which relates the working fluid temperature with the vital collector geometric and physical design parameters. The exit fluid temperature was used to compute the rate of heat transfer to the working fluid and the efficiency of the transfer. The optimum fluid temperatures obtained for the harmattan, rainy and yearly (or combined seasons were: 317.4, 314.9 and 316.2 [K], respectively. The corresponding insolation utilized were: 83.23, 76.61 and 79.92 [W/m2], respectively, with the corresponding mean collector efficiency of 0.190, 0.205 and 0.197 [-], respectively. The working fluid flowrate, the collector length and the range of time that gave rise to maximum results were: 0.0093 [kg/s], 2.0 [m] and 12PM - 13.00PM, respectively. There was good agreement between the computed and the measured working fluid temperatures. The results obtained are useful for the optimal design of the solar collector and its operations.

  8. A dynamic performance simulation model of flat-plate solar collectors for a heat pump system

    Energy Technology Data Exchange (ETDEWEB)

    Arinze, E.A.; Schoenau, G.J.; Sokhansanj, S. (Saskatchewan Univ., Saskatoon, SK (Canada). College of Engineering); Adefila, S.S.; Mumah, S.M. (Ahmadu Bello Univ., Zaria (Nigeria). Dept. of Chemical Engineering)

    1993-01-01

    Flat-plate collectors are inherently exposed to time-varying meteorological and system parameters. Thus, dynamic modeling, rather than the commonly used steady-state models, is a more accurate approach for the design and performance evaluation of flat-plate solar collectors. The dynamic model presented in this study describes the fluid, plate and cover temperatures of the collector by three different differential equations. Taylor series expansion and the Runge-Kutta method are used in the solution of the differential equations. The accuracy of the dynamic model was tested by comparing the results predicted by the model with experimental performance data obtained for a liquid-cooled flat-plate solar collector with a corrugated transparent fiberglass cover. The predicted results by the dynamic model agreed favorably with the measured experimental data for the flat-plate solar collector. Experimentally determined collector temperatures varied by a maximum of [+-]3[sup o]C from values predicted by the model. (Author)

  9. Numerical 3-D heat flux simulations on flat plate solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Villar, N. Molero; Lopez, J.M. Cejudo; Munoz, F. Dominguez; Garcia, E. Rodriguez; Andres, A. Carrillo [Grupo de Energetica, Escuela Tecnica Superior de Ingenieros Industriales, UMA, Plaza El Ejido s/n, 29013 Malaga (Spain)

    2009-07-15

    A transient 3-D mathematical model for solar flat plate collectors has been developed. The model is based on setting mass and energy balances on finite volumes. The model allows the comparison of different configurations: parallel tubes collectors (PTC), serpentine tube collectors (STC), two parallel plate collectors (TPPC), and other non-usual possibilities like the use of absorbent fluids with semitransparent or transparent plates. Transparent honeycomb insulation between plate and cover can also be modelled. The effect of temperature on the thermal properties of the materials has also been considered. The model has been validated experimentally with a commercial PTC. The model is a useful tool to improve the design of plate solar collectors and to compare different configurations. In order to show the capabilities of the model, the performance of a PTC collector with non-uniformity flow is analysed and compared with experimental data from literature with good agreement. (author)

  10. Investigation of one-dimensional heat flow in a solarflat plate collector with sun tracing system

    Directory of Open Access Journals (Sweden)

    H Samimi Akhijahani

    2016-09-01

    Full Text Available Introduction Drying is one of the most common methods for storing food and agricultural products. During drying process, free water that causes the growth of microorganisms and spoilage of products is removed from the product. There are several methods for drying of agricultural products. one of the most important methods of investment is drying by using sunlight. Iran is situated at 25- 43oE longitude and mean solar radiation is about 4.9 kwh.m-2.d-1. Because of the proper solar radiations in 95% of the agricultural areas in Iran, solar drying is widely used for drying of fruits and vegetables. The use of solar dryer causes saving in energy consumption and processing costs for drying of products in farms and gardens. Several researchers investigated heat transfer and heat flow in dryers. Selection of appropriate method was carried out for drying of agricultural products using heat pump. Experiments were done and mathematical relationships were estimated to obtain correlation parameters between Reynolds number and Nusselt number for the three cases of solar dryer (cabinet, indirect and combination.The best working conditions were determined for three types of solar collectors (flat, finned and corrugated. In this study, the process of heat transfer and heat transfer coefficient of a solar dryer with and without rotation of absorber plate was compared. Materials and Methods The experiments were conducted in Azarshahr, East Azarbayjan province, Iran in September 2014. Newton's law of thermodynamic was used to analyze the working condition of solar absorber. For this purpose the absorber plate was divided into four equal parts. According to the thermal equations and related boundary conditions as well as the relationship between heat transfer coefficient and the temperature gradient, equation 1 for the Nusselet number obtained: 1 Beside the relationship between Nusselt number and heat transfer coefficient is defined as equation 2: 2 Finally

  11. Heat Transfer Analysis of a Flat-plate Solar Collector Running a Solid Adsorption Refrigerator

    Directory of Open Access Journals (Sweden)

    S. Thiao

    2014-05-01

    Full Text Available Adsorption solar cooling appears to have prospect in the tropical countries. The present study is a theoretical investigation of the performance of a solar adsorption refrigerator using a flat-plate solar collector. The values of glass cover and absorber plate temperatures obtained from numerical solutions of heat balance equations are used to predict the solar coefficient of performance of the solar refrigerator. The simulation technique takes into account the variations of ambient temperature and solar radiation along the day. The effects of optical parameters of the glass cover such as absorption and transmission coefficients on glass cover and absorber plate temperatures and consequently on the coefficient of performance are analyzed. As a result, it is found that the absorber plate temperature is less to the absorption coefficient than the cover glass temperature. Also the thermal radiation exchange has more effect on the cover glass temperature. The higher values of COP are obtained between 11 and 13 h during the morning when the temperatures of the absorber plate and the ambient temperatures increase. Moreover the COP increases with the coefficient of transmission of the glass cover but the main parameter acting on the variations of the COP remains the temperature of the evaporator.

  12. Heat transfer performance of silver/water nanofluid in a solar flat-plate collector

    OpenAIRE

    Lazarus, Godson; Roy, Siddharth; Kunhappan, Deepak; Cephas, Enoch; Wongwises, Somchai

    2015-01-01

    An experimental study is carried out to investigate the heat transfer characteristics of silver/water nanofluid in a solar flatplate collector. The solar radiation heat flux varies between 800 W/m2and 1000W/m2, and the particle concentration varies between 0.01%, 0.03%, and 0.04%. The fluid Reynolds number varies from 5000 to 25000. The influence of radiation heat flux, mass flow rate of nanofluid, inlet temperature into the solar collector, and volume concentration of the particle on the con...

  13. Analysis of the Thermal Performance of a Solar Water Heating System with Flat Plate Collectors in a Temperate Climate

    OpenAIRE

    Ayompe, Lacour; DUFFY Aidan

    2013-01-01

    The thermal performance of a solar water heating system with 4 m2 flat plate collectors in Dublin, Ireland is presented in this paper. The experimental setup consisted of a commercially available forced circulation domestic scale system fitted with an automated sub‐system that controlled hot water draw‐offs and the operation of an auxiliary immersion heater. The system was tested over a year and the maximum recorded collector outlet fluid temperature was 70.4 oC while the maximum water temper...

  14. The sizes of Flat Plate and Evacuated Tube Collectors with Heat Pipe area as a function of the share of solar system in the heat demand

    Directory of Open Access Journals (Sweden)

    Olek Małgorzata

    2016-01-01

    Full Text Available The popularity of solar collectors in Poland is still increasing. The correct location of the collectors and a relatively high density of solar radiation allow delivering heat even in spite of relatively low ambient temperature. Moreover, solar systems used for heating domestic heat water (DHW in summer allow nearly complete elimination of conventional energy sources (e.g. gas, coal. That is why more and more house owners in Poland decide to install solar system installations. In Poland the most common types of solar collectors are flat plate collectors (FPC and evacuated tube collectors with heat pipe (ETCHP; both were selected for the analysis. The heat demand related to the preparation of hot water, connected with the size of solar collectors’ area, has been determined. The analysis includes FPC and ETCHP and heat demand of less than 10 000 kWh/year. Simulations were performed with the Matlab software and using data from a typical meteorological year (TMY. In addition, a 126–year period of measurements of insolation for Krakow has been taken into account. The HDKR model (Hay, Davis, Klucher, Reindl was used for the calculation of solar radiation on the absorber surface. The monthly medium temperature of the absorber depends on the amount of solar system heat and on the heat demand. All the previously mentioned data were used to determine solar efficiency. Due to the fact that solar efficiency and solar system heat are connected, the calculations were made with the use of an iterative method. Additionally, the upper limit for monthly useful solar system heat is resulted from the heat demand and thus the authors prepared a model of statistical solar system heat deviations based on the Monte Carlo method. It has been found that an increase in the useful solar system heat in reference to the heat demand is associated with more than proportional increase in the sizes of the analyzed surfaces of solar collector types.

  15. High performance flat plate solar collector

    Science.gov (United States)

    Lansing, F. L.; Reynolds, R.

    1976-01-01

    The potential use of porous construction is presented to achieve efficient heat removal from a power producing solid and is applied to solar air heaters. Analytical solutions are given for the temperature distribution within a gas-cooled porous flat plate having its surface exposed to the sun's energy. The extracted thermal energy is calculated for two different types of plate transparency. Results show the great improvement in performance obtained with porous flat plate collectors as compared with analogous nonporous types.

  16. Flat plate collectors as facade elements for domestic hot water and heat insulation. Flachkollektoren als Fassadenelemente zur Brauchwassererwaermung und Waermedaemmung

    Energy Technology Data Exchange (ETDEWEB)

    Flamm, H.; Lochau, R.; Maeiss, M.; Schiele, J.

    1984-07-01

    In a newly constructed south-west-facade 200 m/sup 2/ of flat plate collectors were integrated as construction elements to heat domestic water. The building needs 5-10 m/sup 3/ of hot water per day, i.e. 250-500 kWh/d. The solar circuit runs with a water-glycol-mixture with a specific volume flow rate of 20-40 l/m/sup 2/h. The storage capacity is 8 m/sup 3/, i.e. 40 l/m/sup 2/ collector area. The heating system is bivalent. The total cost was DM 220.000, excepting the cost of facade construction. The observation period was 2 years. The heat flow balance was measured daily using a microprocessor. As far as the construction was concerned, there were no defects during the observation period. The rooms behind solar collectors showed no additional thermal load. The most favourable season for running solar systems is from April to September. In this period the average efficiencies were 15 to 20%, the net energy yield was 76 kWh/m/sup 2/.

  17. Heat loss coefficients and effective tau-alpha products for flat-plate collectors with diathermanous covers

    Science.gov (United States)

    Hollands, K. G. T.; Wright, J. L.

    1983-01-01

    This paper presents an efficient algorithm for solving the set of nonlinear equations governing the total heat transfer across an arbitrary number of parallel flat plate solar collector covers, each of which can be partly transparent to longwave thermal radiation. The governing equations are sufficiently general to permit each cover to have asymmetric radiative properties and to account for absorption of solar energy on the individual covers. This theory is shown to be in good agreement with the approximate equations of Whillier (provided certain interpretations are placed on his quantities) and with experiments using a plastic inner cover and bounding plates of various emissivities. Using this theory, it is demonstrated that if the absorber plate has a selective surface, an inner cover transparent to long wave radiation is to be preferred over one which is opaque.

  18. Efficiencies of flat plate solar collectors at different flow rates

    DEFF Research Database (Denmark)

    Chen, Ziqian; Furbo, Simon; Perers, Bengt;

    2012-01-01

    Two flat plate solar collectors for solar heating plants from Arcon Solvarme A/S are tested in a laboratory test facility for solar collectors at Technical University of Denmark (DTU). The collectors are designed in the same way. However, one collector is equipped with an ETFE foil between...... the absorber and the cover glass and the other is without ETFE foil. The efficiencies for the collectors are tested at different flow rates. On the basis of the measured efficiencies, the efficiencies for the collectors as functions of flow rate are obtained. The calculated efficiencies are in good agreement...

  19. Increasing thermal efficiency of solar flat plate collectors

    Science.gov (United States)

    Pona, J.

    A study of methods to increase the efficiency of heat transfer in flat plate solar collectors is presented. In order to increase the heat transfer from the absorber plate to the working fluid inside the tubes, turbulent flow was induced by installing baffles within the tubes. The installation of the baffles resulted in a 7 to 12% increase in collector efficiency. Experiments were run on both 1 sq ft and 2 sq ft collectors each fitted with either slotted baffles or tubular baffles. A computer program was run comparing the baffled collector to the standard collector. The results obtained from the computer show that the baffled collectors have a 2.7% increase in life cycle cost (LCC) savings and a 3.6% increase in net cash flow for use in domestic hot water systems, and even greater increases when used in solar heating systems.

  20. Numerical analysis of flow and heat transfer behavior in fin-tube flat-plate solar collector

    Institute of Scientific and Technical Information of China (English)

    Namory Camara; LU Hui-lin

    2007-01-01

    Temperature distribution over the absorber plate of a parallel flow flat-plate solar collector is numerically analyzed. The governing differential equations with boundary conditions are solved numerically using fluent software. Effects of the inlet mass flux, inlet temperature and tube spacing on velocity and temperature distributions are discussed. Numerical results show that the distributions of velocity and temperature of fluid is unsymmetrical inside pipe.

  1. REVIEW OF PERFORMANCE AND ANALYSIS ISI FLAT PLATE COLLECTOR WITH MODIFIED FLAT PLATE COLLECTOR

    Directory of Open Access Journals (Sweden)

    MR.Y.Y.NANDURKAR

    2012-03-01

    Full Text Available The market of solar water heater of natural circulation type (thermo-siphon is fast growing in India. Initial cost of the solar water heater system at present is high because of store type design. It is necessary to make the product more popular by reducing the cost. This is possible by reducing area of liquid flat plate collector by increasing tube diameter and reducing riser length. Hence it is essential to make solar water heater in affordable range of the general public class. Present work is based on review of comparative performance and analysis of ISI flat plate collector with modified flat plat collector. The paper will be helpful for those who are working in the area of solar water heating system and their use in domestic areas.

  2. Experimental investigation on a flat plate solar collector using Al2O3 Nanofluid as a heat transfer agent

    Directory of Open Access Journals (Sweden)

    Abbas Sahi Shareef, Mohammed Hassan Abbod, Sura Qahtan Kadhim

    2015-01-01

    Full Text Available This work introduces experimental results of an Al2O3 -water based nanofluid as the working fluid for flat tube in plate type solar collector. Experimental test setup comprises a solar collector, closed working fluid system and measurement devices (flow meter, thermocouples, temperature meter and digital solar power meter. The Base case was experimented with di-ionized water with a flow rate of 1 lpm. In second case, Al2O3 nanoparticles are mixed in di-ionized water to get nanofluid of 0.5% volume fraction concentration. The maximum difference between outlet and inlet temperatures of the solar collector was 14.4 ̊ C with the solar irradiance of about 788 W/m2 while in case of water the maximum temperatures difference was 10.7 ̊ C with a solar irradiance of about 781 W/m2.

  3. Recommendations for European solar collector test methods (Liquid heating collectors)

    Science.gov (United States)

    Derrick, A.; Gillett, W. B.

    Standardized testing formats, equipment, conditions, and tests defined as part of the solar flat plate collector testing program performed by the Commission of the European Communities are detailed. The work is a product of efforts at 20 laboratories, and alternative methods have been characterized for tailoring tests to particular locations and climatic conditions. The testing methods are intended for collectors using a liquid as the heat transfer medium. Procedures have been defined for examining steady state and transient performance, heat loss, thermal capacity, pressure drop, and anemometry. Instrumentation types and accuracies have been defined, and a standardized format for presentation of results has been developed. The tests are tailored for determining the durability of the flat plate systems under simulated solar radiation conditions.

  4. Solar Heating Systems with Evacuated Tubular Solar Collector

    DEFF Research Database (Denmark)

    Qin, Lin; Furbo, Simon

    1998-01-01

    , as well as with normal flat-plate collectors was calculated under Danish weather conditions. It is found that, for small SDHW systems with a combi tank design, an increase of 25% -55% net utilized solar energy can be achieved by using these evacuated tubular collectors instead of normal flat......-plate collectors. For solar heating plants, the yearly energy output from these evacuated tubular collectors is about 40%-90% higher than the output from typical flat-plate collectors at an operation temperature of about 50°C.......Recently different designed evacuated tubular solar collectors were introduced on the market by different Chinese companies. In the present study, investigations on the performance of four different Chinese evacuated tubular collectors and of solar heating systems using these collectors were...

  5. A 2-dimensional heat transfer analysis of a sheet-and-tube flat plate PV/thermal collector

    Energy Technology Data Exchange (ETDEWEB)

    Carriere, J.; Harrison, S. [Queen' s Univ., Kingston, ON (Canada). Dept. of Mechanical and Materials Engineering Solar Calorimetry Lab

    2008-08-15

    Temperature gradients in photovoltaic/thermal (PV/T) systems can have a significant impact on the reliability and life-span of system components. However, many simple PV/T models do not consider temperature gradients. In this study, a detailed heat transfer model was used to quantify temperature gradients within a PV/T panel in order to predict thermal and electrical performance as a function of fluid and atmospheric temperatures. The PV/T system consisted of a PV laminate bonded to a thermal collector. A glass cover was used as a secondary glazing system. The effect of increasing the thermal resistance between the various layers in the construction was evaluated in order to measure the temperature gradient through the absorber thickness. A 2-D finite difference model of heat flow in the collector was conducted in order to study the magnitude of the temperature gradient. Steady-state heat flow was calculated along the width of the system as well as between the layers. Heat flux was calculated to the centre of each element. Total absorptivity in each layer was determined by adding the absorption of each portion of the spectrum. Heat losses through the top of the collector were estimated using a 1-D analysis. The study showed that current methods of calculating fin efficiency are not valid when temperature gradients are not considered. Future studies will examine the effect of thermal expansion and shear stresses. 9 refs., 8 figs.

  6. A high performance porous flat-plate solar collector

    Science.gov (United States)

    Lansing, F. L.; Clarke, V.; Reynolds, R.

    1979-01-01

    A solar collector employing a porous matrix as a solar absorber and heat exchanger is presented and its application in solar air heaters is discussed. The collector is composed of a metallic matrix with a porous surface which acts as a large set of cavity radiators; cold air flows through the matrix plate and exchanges heat with the thermally stratified layers of the matrix. A steady-state thermal analysis of the collector is used to determine collector temperature distributions for the cases of an opaque surface matrix with total absorption of solar energy at the surface, and a diathermanous matrix with successive solar energy absorption at each depth. The theoretical performance of the porous flat plate collector is shown to exceed greatly that of a solid flat plate collector using air as the working medium for any given set of operational conditions. An experimental collector constructed using commercially available, low cost steel wool as the matrix has been found to have thermal efficiencies from 73 to 86%.

  7. 混合工质太阳能平板热管集热器的传热性能%Heat Transfer Performance ofthe Flat Plate Heat Pipe Solar Collector with Mixture Working Fluid

    Institute of Scientific and Technical Information of China (English)

    杜胜华; 苏海鹏

    2014-01-01

    介绍了平板热管的基本结构与原理,在分析乙二醇及其混合工质的热物理学特性的基础上,建立平板热管的物理与数学模型。采用数值计算模拟方法,分析了混合工质平板热管集热器的传热性能,研究了集热器的效率、温升和启动性能随工作时间的变化规律。研究表明,乙二醇水混合工质平板热管集热器适宜于低温寒冷地区,具有较高的集热性能。%The basic structure and principle of flat plate heat pipe were introduced based on thermal physics characteristics analysis of ethylene glycol and mixtures , physical and mathematical models of flat plate heat pipe were established.By the numerical simulation method , the heat transfer performance of the flat heat pipe heat collector with mixture working fluid was analyzed , and the efficiency , temperature collector up and starting performance by time were studied.It showed that flat heat pipe heat collector with ethylene glycol water mixture was suitable for cold area , and the heat collecting performance was high.

  8. Validation of CFD simulation for flat plate solar energy collector

    Energy Technology Data Exchange (ETDEWEB)

    Selmi, Mohamed; Al-Khawaja, Mohammed J.; Marafia, Abdulhamid [Department of Mechanical Engineering, University of Qatar, P.O. Box 2713, Doha, State of Qatar (Qatar)

    2008-03-15

    The problem of flat plate solar energy collector with water flow is simulated and analyzed using computational fluid dynamics (CFD) software. The considered case includes the CFD modeling of solar irradiation and the modes of mixed convection and radiation heat transfer between tube surface, glass cover, side walls, and insulating base of the collector as well as the mixed convective heat transfer in the circulating water inside the tube and conduction between the base and tube material. The collector performance, after obtaining 3-D temperature distribution over the volume of the body of the collector, was studied with and without circulating water flow. An experimental model was built and experiments were performed to validate the CFD model. The outlet temperature of water is compared with experimental results and there is a good agreement. (author)

  9. Electrostatic particle collector with improved features for installing and/or removing its collector plates

    Energy Technology Data Exchange (ETDEWEB)

    Siegfried, Matthew J.; Radford, Daniel R.; Huffman, Russell K.

    2017-04-04

    An electrostatic particle collector may generally include a housing having sidewalls extending lengthwise between a first end and a second end. The housing may define a plate slot that extends heightwise within the housing between a top end and a bottom end. The housing may further include a plate access window that provides access to the bottom end of the plate slot. The collector may also include a collector plate configured to be installed within the plate slot that extends heightwise between a top edge and a bottom edge. Additionally, when the collector plate is installed within the plate slot, the bottom edge of the collector plate may be accessible from an exterior of the housing via the plate access window so as to allow the bottom edge of the collector plate to be moved relative to the housing to facilitate removal of the collector plate from the housing.

  10. Application of the Heat Pipe in Flat-Plate Solar Collectors%热管在平板式太阳能集热器中的应用研究

    Institute of Scientific and Technical Information of China (English)

    黄婷婷; 杜娜; 卿湛媛; 陈新; 牛宝联

    2014-01-01

    从集热器结构、传热效率、工艺、优缺点等方面详细介绍了3种常见的热管平板式太阳能集热器,它们包括蜂窝热管平板式、真空玻璃盖板热管平板式、CPC热管平板式太阳能集热器。与普通热管平板式集热器相比,3种改良方式均可降低集热器热损失,有效提高集热效率。通过对不同种类热管平板式太阳能集热器的热管种类、工作温度、结构参数等分析,发现随着温度升高,集热器集热效率下降,以及热管蒸发段长度普遍大于冷凝段长度等现象。%Three common heat pipe flat-plate solar collectors are introduced in details from the con-figuration of the collector such as heat transfer efficiency, crafts, merits, and so on, including the flat plate solar collector of honeycomb and heat pipe(HHCHP), flat plate solar collector of vacuum glass-cover board and heat pipe(HVGHP) and a compound parabolic concentrator heat pipe type solar collector(CPC). Com-pared with common heat pipe flat-plate solar collectors, these three improved programs can reduce heat loss, and effectively improve efficiency of the collector. From the analysis of different heat pipe types, oper-ating temperature, structure parameters, a phenomenon is discovered that whatever which type of heat pipe flat-plate solar collector is, as temperature goes up, the efficiency of the collectors drops and the length of evaporation is longer than the length of condensation.

  11. High temperature flat plate solar collector

    Energy Technology Data Exchange (ETDEWEB)

    Hozumi, S.; Aso, S.; Ebisu, K.; Uchino, H.

    1981-04-01

    Improvements in the efficiency of collectors are of great importance for extending the utilization of solar energy for heating and cooling in homes. A highly efficient collector makes the system size small and decreases the system cost effectively. From the view of the amount of energy collected, the efficient collector has a multiple effect, not only because of the high increase in instantaneous efficiency, but also because of the large usable intensity range of the insolation. On the basis of a functional analysis for a flat collector, the materials and parameters were selected and optimized, and a new high temperature flat collector was designed. The collector has 2 panes. The first pane is low iron glass and the second pane is a thin film of fluorinated ethylene-propylene copolymer. The overall solar transmittance for the two panes is 0.89. The collecting panel and its water paths were formed by means of welding and hydraulic expansion. The selective absorbing surface consists of colored stainless steel whose absorption characteristic is 0.89 and emission characteristic is 0.16. The thermal insulator preventing backward heatloss consists of double layers of urethane foam and glass wool. Furthermore, the sustained method for the second pane is contrived so as to prevent water condensation on the panes and excessive elevation of the absorber temperature during no load heating.

  12. EFFICIENCY AND LIFETIME OF SOLAR COLLECTORS FOR SOLAR HEATING PLANTS

    OpenAIRE

    Fan, Jianhua; Chen, Ziqian; Furbo, Simon; Perers, Bengt; Karlsson, Björn

    2009-01-01

    The 12.5 m² flat plate solar collector HT, today marketed by Arcon Solvarme A/S, has been used in solar heating plants in Scandinavia since 1983. The collector is designed to operate in a temperature interval between 40°C and 90°C. The efficiency of the collector has been strongly improved since it was introduced on the market. The paper will present the increase of the efficiency of the collector due to technical improvements since 1983. Further, measurements from the spring of 2009 of the e...

  13. Enhancing the Heat Transfer of Flat-plate Solar Collector%平板太阳能集热器强化传热应用研究进展∗

    Institute of Scientific and Technical Information of China (English)

    吉佳文; 王文志; 李金凯; 段广彬; 刘宗明

    2016-01-01

    As the key part of the flat-plate solar water heater,the heat transfer performance of the collector is determined by the heat collector efficiency.The flat-plate solar collector with typical structure and heat transfer mode are described.Meanwhile the present technologies for enhancing heat transfer of flat-plate solar collector and the fu-ture development trend are reviewed and discussed.%集热器作为平板太阳能热水器的关键部分,其传热性能决定着热水器集热效率的高低。介绍了平板太阳能集热器的典型结构以及传热方式,综述了平板太阳能集热器目前所采用的强化传热方式及今后强化传热技术的发展趋势。

  14. COMPARATIVE FIELD EXPERIMENTAL INVESTIGATIONS OF DIFFERENT FLAT PLATE SOLAR COLLECTORS

    Directory of Open Access Journals (Sweden)

    Guangming Chen

    2015-12-01

    Full Text Available Full-scale traditional metal solar collectors and solar collector specimens fabricated from polymeric materials were investigated in the present study. A polymeric collector is 67.8% lighter than a traditional metal solar collector, and a metal solar collector with transparent plastic covering is 40.3% lighter than a traditional metal solar collector. Honeycomb multichannel plates made from polycarbonate were chosen to create a polymeric solar collector. A test rig for the natural circulation of the working fluid in a solar collector was built for a comparative experimental investigation of various solar collectors operating at ambient conditions. It was shown experimentally that the efficiency of a polymeric collector is 8–15% lower than the efficiency of a traditional collector.

  15. Experimental and numerical investigation of a flat-plate solar collector

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez, A. [Departamento de Construcciones Navales, E.U. Politecnica, Universidade da Coruna, 15405 Ferrol (Spain); Cabeza, O. [Departamento de Fisica, Universidade da Coruna, 15072 A Coruna (Spain); Muniz, M.C. [Departamento de Matematica Aplicada, Universidade de Santiago de Compostela, 15782 Santiago de Compostela (Spain); Varela, L.M. [Departamento de Fisica de la Materia Condensada, Universidade de Santiago de Compostela, 15782 Santiago de Compostela (Spain)

    2010-09-15

    In the present paper we present an experimental analysis and a thermal and hydrodynamic modelling of a newly designed flat-plate solar collector characterized by its corrugated channel and by the high surface area directly in contact with the heat transport fluid. The thermal and hydrodynamic modelling of the collector has been performed by means of the Finite Element Method (FEM), validated with analytical results for a well-known fin-and-tube type solar collector. The thermodynamic efficiency of the collector is analyzed by means of its experimental heating curves. The yield of the new collector has been compared to a previously existing commercial collector of related geometry but with less area in direct contact with the heat transport fluid. The experimental results are seen to adequately fit the simulation predictions, and a methodology to use in order to compute the parameters characterizing the thermal behavior of the collector is introduced. (author)

  16. Performance Study of a Double-Pass Thermoelectric Solar Air Collector with Flat-Plate Reflectors

    Science.gov (United States)

    Lertsatitthanakorn, C.; Rungsiyopas, M.; Therdyothin, A.; Soponronnarit, S.

    2012-06-01

    In this paper the results of the influence of flat-plate reflectors made of aluminum foil on the performance of a double-pass thermoelectric (TE) solar air collector are presented. The proposed TE solar collector with reflectors was composed of transparent glass, an air gap, an absorber plate, TE modules, a rectangular fin heat sink, and two flat-plate reflectors. The flat-plate reflectors were placed on two sides of the TE solar collector (east and west directions). The TE solar collector was installed on a one-axis sun-tracking system to obtain high solar radiation. Direct and reflected incident solar radiation heats up the absorber plate so that a temperature difference is created across the TE modules to generate a direct current. Only a small part of the absorbed solar radiation is converted to electricity, while the rest increases the temperature of the absorber plate. Ambient air flows through the heat sink located in the lower channel to gain heat. The heated air then flows to the upper channel, where it receives additional heating from the absorber plate. Improvements to the thermal energy and electrical power outputs of the system can be achieved by the use of the double-pass collector system with reflectors and TE technology. It was found that the optimum position of the reflectors is 60°, which gave significantly higher thermal energy and electrical power outputs compared with the TE solar collector without reflectors.

  17. Therminol VP-1导热油平板太阳能集热器的热工性能测试实验%Therminol VP-1 Heat Transfer Fluid Plate Solar Collector Thermal Performance Test

    Institute of Scientific and Technical Information of China (English)

    唐千喻; 王华; 王辉涛; 卿山

    2011-01-01

    Due to the advantages and disadvantages ofstructure of solar collectors, developed a new type of heat transfer fluid plate solar collectors, and test its performance. Measured results, it can achieve the thermal efficiency of 0.45, higher than the conventional flat solar collector Shows that the heat transfer fluid superior performance, have a good prospect.%针对市场上的平板太阳能集热器结构的优缺点,研制了新型的导热油平板太阳能集热器,并测试其性能.实测结果为,热效率能达到0.45,比普通平板集热器高.表明该导热油平板太阳能集热器性能优越,有很好的应用前景.

  18. A Didactic Experiment and Model of a Flat-Plate Solar Collector

    Science.gov (United States)

    Gallitto, Aurelio Agliolo; Fiordilino, Emilio

    2011-01-01

    We report on an experiment performed with a home-made flat-plate solar collector, carried out together with high-school students. To explain the experimental results, we propose a model that describes the heating process of the solar collector. The model accounts quantitatively for the experimental data. We suggest that solar-energy topics should…

  19. Effect of openings collectors and solar irradiance on the thermal efficiency of flat plate-finned collector for indirect-type passive solar dryer

    Science.gov (United States)

    Batubara, Fatimah; Dina, Sari Farah; Klaudia Kathryn Y., M.; Turmuzi, M.; Siregar, Fitri; Panjaitan, Nora

    2017-06-01

    Research on the effect of openings solar collector and solar irradiance to thermal efficiency has been done. Solar collector by flat plate-finned type consists of 3 ply insulator namely wood, Styrofoam and Rockwool with thickness respectively are 10 mm, 25 mm and 50 mm. Absorber plate made of aluminum sheet with thickness of 0.30 mm, painted by black-doff. Installation of 19 units fins (length x height x thickness: 1000x20x10 mm) on the collector will increase surface area of absorber so it can receive much more solar energy. The solar collector cover is made of glass (thickness of 5 mm). During the research, the solar irradiance and temperature of collector are measured and recorded every five minutes. Temperature measurement performed on the surface of the absorber plate, inside of collector, surface cover and the outer side insulator (plywood). This data is used to calculate the heat loss due to conduction, convection and radiation on the collector. Openings of collectors vary as follows: 100%, 75%, 15% and 0% (total enclosed). The data collecting was conducted from 09.00 am to 17.00 pm and triplicates. The collector thermal efficiency calculated based on the ratio of the amount of heat received to the solar irradiance absorbed. The results show that each of openings solar collector has different solar irradiance (because it was done on a different day) which is in units of W/m2: 390 (100% open), 376 (75% open), 429 (15% open), and 359 (totally enclosed). The highest thermal efficiency is in openings variation of 15% opened. These results indicate that the efficiency of the collector is influenced by the solar irradiance received by the collector and the temperature on the collector plate. The highest thermal efficiency is in variation of openings 15%. These indicate that the efficiency of the collector was influenced by solar irradiance received by the collector and openings of the collector plate.

  20. A Dynamic Multinode Model for Component-Oriented Thermal Analysis of Flat-Plate Solar Collectors

    OpenAIRE

    Reiter, Christoph N.; Christoph Trinkl; Wilfried Zörner; Hanby, Vic I.

    2015-01-01

    A mathematical model of a flat-plate solar collector was developed on the basis of the physical principles of optics and heat transfer in order to determine collector’s component temperatures as well as collector efficiency. In contrast to many available models, the targeted use of this dynamic model is the detailed, theoretical investigation of the thermal behaviour of newly developed or adjusted collector designs on component level, for example, absorber, casing, or transparent cover. The d...

  1. A dynamic simulation of a flat-plate collector system

    Science.gov (United States)

    Annino, A.

    1983-04-01

    A numerical model for the performance of a flat plate solar collector array is presented, with account taken of thermal transients and calculation on a microcomputer. The system modeled consists of a flat plate array, the heat transfer fluid, an insulated storage tank, an exchange loop for heating a secondary fluid, and a load maintained by a pump. The one-dimensional analysis includes equations for the energy balances, with consideration given to heat losses to the outside. A function is defined for the total incident solar radiation, and behavior is simulated over the entire 24-hr day, weighted by the highest and lowest recorded temperatures. Good agreement has been found with experimental data.

  2. A diagram for defined solar radiation absorbed per unit area of flat plate solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Tekin, Y.; Altuntop, N. [Erciyes University, Dept. of Mechanical Engineering (Turkey); Cengel, Y.A. [Nevada Reno University, Dept. of Mechanical Engineering, NV (United States); Cengel, Y.A. [Nevada University, Dept. Mechanical Engineering, Reno, NV (United States)

    2000-07-01

    In Erciyes University, the Solar House (28.75 m{sup 2}) is heated from the floor by using flat plate liquid solar collectors. Required solar radiation for heating and heat losses are calculated. In this work, the required calculations for Erciyes Solar House were generalized and required calculation were done to evaluate absorbed solar radiation per unit surface of the flat plate liquid collector. At the end, three generalized diagrams for nine different months are obtained using obtained numerical values. The goal of preparing diagrams is to determine absorbed solar radiation per unit surface area of flat plate liquid collector at any instant at any latitude, In this work, the diagram is explained by means of sample calculations for November. This diagram was prepared to find out absorbed solar radiation per unit area of black surface collector by means obtained equations. With this diagram, all instant solar radiation can be evaluated in 19 steps. (authors)

  3. A graphical approach to the efficiency of flat-plate collectors

    Science.gov (United States)

    Selcuk, M. K.

    1978-01-01

    A nomogram is described which can be used to determine the thermal performance of flat plate solar collectors, resulting in two performance factors: the net absorptance and the net heat loss coefficient. The nomogram takes into account angle of incidence, collector slope, absorber plate design, insulating materials, thicknesses, optical properties of absorbing surfaces and glazing materials, and flow factors. A case example is given to illustrate the use of the nomogram.

  4. EFFICIENCY AND LIFETIME OF SOLAR COLLECTORS FOR SOLAR HEATING PLANTS

    DEFF Research Database (Denmark)

    Fan, Jianhua; Chen, Ziqian; Furbo, Simon

    2009-01-01

    The 12.5 m² flat plate solar collector HT, today marketed by Arcon Solvarme A/S, has been used in solar heating plants in Scandinavia since 1983. The collector is designed to operate in a temperature interval between 40°C and 90°C. The efficiency of the collector has been strongly improved since...... it was introduced on the market. The paper will present the increase of the efficiency of the collector due to technical improvements since 1983. Further, measurements from the spring of 2009 of the efficiency of two HT collectors, which have been in operation in the solar heating plant Ottrupgaard, Skørping......, Denmark since 1994 with a constant high flow rate and in the solar heating plant Marstal, Denmark since 1996 with a variable flow rate, will be presented. The efficiencies will be compared to the efficiencies of the collectors when they were first installed in the solar heating plants. The measurements...

  5. EFFICIENCY AND LIFETIME OF SOLAR COLLECTORS FOR SOLAR HEATING PLANTS

    DEFF Research Database (Denmark)

    The 12.5 m² flat plate solar collector HT, today marketed by Arcon Solvarme A/S, has been used in solar heating plants in Scandinavia since 1983. The collector is designed to operate in a temperature interval between 40°C and 90°C. The efficiency of the collector has been strongly improved since...... it was introduced on the market. The paper will present the increase of the efficiency of the collector due to technical improvements since 1983. Further, measurements from the spring of 2009 of the efficiency of two HT collectors, which have been in operation in the solar heating plant Ottrupgaard, Skørping......, Denmark since 1994 with a constant high flow rate and in the solar heating plant Marstal, Denmark since 1996 with a variable flow rate, will be presented. The efficiencies will be compared to the efficiencies of the collectors when they were first installed in the solar heating plants. The measurements...

  6. REVIEW ON POROUS AND NON-POROUS FLAT PLATE AIR COLLECTOR WITH MIRROR ENCLOSURE

    Directory of Open Access Journals (Sweden)

    M. PRADHAPRAJ,

    2010-09-01

    Full Text Available In solar air heater, flat plat collectors are the best heat transferring devices. But the effectiveness of these collectorsis very low because of lack of technology. Solar assisted heated air is successfully used for drying applications and space heating under controlled conditions. From the solar flat plate air heater the hot air is transferred to a conventional dryer or to the combined heater and drying chamber directly. Hence, solar assisted air heaters arecheaper and reliable. The important factors affecting these systems are the solar radiation, mechanical loading, temperature and leakage. The air heater efficiency depends on the design of the system as well as the construction materials and the assembly. The solar air heating systems has acceptable life span of 15 to 20 years. The addition ofside mirror enclosures is to increase the amount of solar radiation absorption at the collector plate so that the collector increases the yield and operate in a higher temperature range. Therefore with the addition of side mirrors one can able to maximize the output of fixed flat plate collectors. A flat plate air collector will be more efficient if it is made up of porous medium when comparing it with the non porous collectors according to the study. In this paper, the performances of porous and non-porous absorber plates are discussed. Also the possible methods of finding out air leakages and the methodology adopted for the performance and efficiency calculations are also discussed.

  7. Natural convection characteristics of flat plate collectors. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Randall, K.R.; Wl-Wakil, M.M.; Mitchell, J.W.

    1977-09-01

    The results of an experimental investigation into the convective heat losses in large aspect ratio flat-plate solar collectors are described. An experimental study has been undertaken on a specially designed test cell using a 3 inch Mach-Zehnder interferometer. Air at atmospheric pressure was used as the heat-transfer fluid. The experimental results include interferograms which show the thermal boundary layer formations and the temperature profiles. Local temperature profiles have been analyzed through the use of an optical comparator to determine local Nusselt number profiles, which have, in turn, been integrated to give average heat-transfer results. Angles of inclination from the horizontal of 45, 60, 75 and 90 degrees have been investigated. Aspect ratios from 9 to 36 were examined over a Rayleigh number range of 4,000 to 310,000. Finally, heat-transfer correlations have been developed for the prediction of local Nusselt numbers in the starting and departure corners and for the average heat-transfer results as a function of collector tilt angle.

  8. Development of 12.5 m² Solar Collector Panel for Solar Heating Plants

    DEFF Research Database (Denmark)

    Vejen, Niels Kristian; Furbo, Simon; Shah, Louise Jivan

    2004-01-01

    Theoretical and experimental investigations have elucidated how different changes in the design of the 12.5 m(2) HT flat-plate solar collector from the Danish company ARCON Solvarme A/S influence the solar collector efficiency and the yearly thermal performance. The collector is designed for medium...... and large solar heating systems. Based on the theoretical findings a prototype of an improved HT solar collector was built and tested side-by-side with the original HT solar collector. The improved HT collector makes use of a changed insulation material, an absorber with improved absorptance and emittance...

  9. EVALUATION OF EVACUATED TUBULAR SOLAR COLLECTORS FOR LARGE SDHW SYSTEMS AND COMBINED SPACE HEATING SYSTEMS

    DEFF Research Database (Denmark)

    Qin, Lin; Furbo, Simon

    1999-01-01

    . Based on thesemodels, the thermal performance of large solar domestic hot water (DHW) systems and combined domestichot water and space heating systems with the four evacuated tubular collectors was determined. To make acomparison with traditional flat-plate collectors, similar simulations were also...... carried out for systems with atypical flat-plate collector. The results show that the thermal advantage of evacuated tubular collectors variesgreatly from system to system, and increases with the solar fraction. Furthermore, the higher the operationtemperature of the collector in the system is......In the present study, detailed investigations on evacuated tubular solar collectors for large solarheating systems have been carried out. Four types of evacuated tubular solar collectors were used in theinvestigation. Based on laboratory tests, simulation models for the collectors were determined...

  10. Water heating solar system using collector with polycarbonate absorber surface

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Luiz Guilherme Meira de; Sodre, Dilton; Cavalcanti, Eduardo Jose Cidade; Souza, Luiz Guilherme Vieira Meira de; Mendes, Jose Ubiragi de Lima [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil)], e-mails: lguilherme@dem.ufrn.br, diltonsodre@ifba.edu.br, ubiragi@ct.ufrn.br

    2010-07-01

    It is presented s solar collector to be used in a heating water for bath system, whose main characteristics are low cost and easy fabrication and assembly processes. The collector absorber surface consists of a polycarbonate plate with an area of 1.5 m{sup 2}. The water inlet and outlet are made of PVC 50mm, and were coupled to a 6mm thick polycarbonate plate using fiberglass resin. A 200 liters thermal reservoir will be used. This reservoir is also alternative. The absorber heating system works under thermo-siphon regimen. Thermal parameters will be evaluated to prove the feasibility of the studied solar heating system to obtain bath water for a four people family. (author)

  11. Influences of the Twisted Strips Insertion on the Performance of Flat Plate Water Solar Collector

    Directory of Open Access Journals (Sweden)

    Jafar M. Hassan

    2015-09-01

    Full Text Available In order to enhance the efficiency of flat plate solar water collectors without changing in its original shape and with low additional cost, twisted strips are inserted inside its riser pipes. Three flat plate collectors are used for test. Family of twisted strips are inserted inside each collector risers with different twisted ratios (TR=3,4,5. The collectors are connected in parallel mode (Z-Configuration and are exposed to the same conditions (solar radiation and ambient temperature .The experimental results show that, the highest heat transfer rate occurs at twisted ratio (3 .Consequently, for the same twisted ratio the daily efficiencies for the solar collector at different flow rate used (60,100 and 150 ℓ /hr. were 49 %, 57% and 63% respectively.

  12. Flat-plate solar-collector performance data base and user's manual

    Science.gov (United States)

    Kirkpatrick, D. L.; Kolar, W. A.

    1983-07-01

    The reader is provided with a thorough understanding on the type of collector thermal performance information which is required in active system design and analysis. Thermal performance test data on 109 commercially available solar collectors which were evaluated in a single, uniform test program, the Interim Solar Collector Test (ISCT) Program are given. In addition to recounting the ISCT program and its results, the an introduction is given on the engineering and physics of a flat-plate solar collector operation. A step-by-step analysis of heat gains and losses is provided to help the reader understand both the source and applicability of the parameters used to describe collector thermal performance. A brief description of the engineering basis for the ASHRAE Standard 93-77 test procedure and the method are included. To demonstrate the sensitivity to variations of collector performance parameters of the annual output of representative solar heating systems, three sets of F-Chart (4.0) system performance predictions are given. Finally, a sensitivity analysis study is presented which considers the heat loss and optical gain parameters of flat-plate collectors, in terms of how they affect the overall solar heating system solar fraction.

  13. Development of high efficiency collector plates. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Santala, T.; Sabol, R.

    1976-02-01

    Composite metal technology was used to manufacture intermetallic compound (IC) absorption surfaces and to combine them integrally with composite metal tube-in-sheet collector plates. Five material systems in which Al was one component metal and Fe, Cr, or Ni and their alloy was the other pair, were evaluated. All intermetallic compounds had high solar absorptance ..cap alpha.. approx. = 0.9. The AlNi was most promising and ..cap alpha.. > or = 0.95 and epsilon approx. = 0.3 were obtained over a broad range of compounding conditions. After eight months exposure in a flat plate collector enclosure the characteristic properties of AlNi surfaces remained virtually unchanged. Only LCS/Cu composite metal tube-in-sheet collector plates could be manufactured successfully. The technical difficulties associated with integrating the intermetallic compound and tube-in-sheet technologies make the manufacturing of composite metal collector plates at the time being economically unfeasible.

  14. High Performance Flat Plate Solar Thermal Collector Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Rockenbaugh, Caleb [National Renewable Energy Lab. (NREL), Golden, CO (United States); Dean, Jesse [National Renewable Energy Lab. (NREL), Golden, CO (United States); Lovullo, David [National Renewable Energy Lab. (NREL), Golden, CO (United States); Lisell, Lars [National Renewable Energy Lab. (NREL), Golden, CO (United States); Barker, Greg [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hanckock, Ed [National Renewable Energy Lab. (NREL), Golden, CO (United States); Norton, Paul [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-09-01

    This report was prepared for the General Services Administration by the National Renewable Energy Laboratory. The Honeycomb Solar Thermal Collector (HSTC) is a flat plate solar thermal collector that shows promising high efficiencies over a wide range of climate zones. The technical objectives of this study are to: 1) verify collector performance, 2) compare that performance to other market-available collectors, 3) verify overheat protection, and 4) analyze the economic performance of the HSTC both at the demonstration sites and across a matrix of climate zones and utility markets.

  15. Improvement of flat plate collectors for solar energy conversion

    Science.gov (United States)

    Boeck, H.; Hallermayer, R.; Schoelkopf, W.; Sizman, R.

    1984-03-01

    Selective absorption for thermal conversion of radiative energy was investigated. Improvement and operation of various measuring devices for absorption and emission are presented. Selective coatings were produced by vapor deposition and galvanic treatment. Calculations of the transmittance of turbular collector fields are presented. Operational Characteristics of Collector were examined. A collector test field with simultaneous recording of data from 24 collectors or uncovered absorbers was built and connected to a high performance microprocessor system. The transient behavior of collectors by variation of the irradiation and the collector inlet temperature were investigated. A mechanism for stratification of hot water of fluctuating inlet temperature in a storage tank was studied. The operating conditions of a heat pump installed in the collector test plant are investigated. A large domestic hot water system is equipped with temperature sensors and flowmeters for computer recording.

  16. Detailed Modeling of Flat Plate Solar Collector with Vacuum Glazing

    Directory of Open Access Journals (Sweden)

    Viacheslav Shemelin

    2017-01-01

    Full Text Available A theoretical analysis of flat plate solar collectors with a vacuum glazing is presented. Different configurations of the collector have been investigated by a detailed theoretical model based on a combined external and internal energy balance of the absorber. Performance characteristics for vacuum flat plate collector alternatives have been derived. Subsequently, annual energy gains have been evaluated for a selected variant and compared with state-of-the-art vacuum tube collectors. The results of modeling indicate that, in the case of using advanced vacuum glazing with optimized low-emissivity coating (emissivity 0.20, solar transmittance 0.85, it is possible to achieve efficiency parameters similar to or even better than vacuum tube collectors. The design presented in this paper can be considered promising for the extension of the applicability range of FPC and could be used in applications, which require low-to-medium temperature level.

  17. Studies on solar flat plate collector evaporation systems for tannery effluent (soak liquor)

    Institute of Scientific and Technical Information of China (English)

    SRITHAR K.; MANIA.

    2006-01-01

    Heat and mass transfer analysis of an incompressible, laminar boundary layer over solar flat plate collector evaporation systems for tannery effluent (soak liquor) is investigated. The goveming equations are solved for various liquid to air velocity ratios. Profiles of velocity, temperature and concentration as well as their gradients are presented. The heat transfer and mass transfer coefficients thus obtained are used to evaluate mass of water evaporated for an inclined fibre-reinforced plastic (FRP)solar flat plate collector (FPC) with and without cover. Comparison of these results with the experimental performance shows encouraging trend of good agreement between them.

  18. Evaluation of heat transfer enhancement in air-heating collectors

    Energy Technology Data Exchange (ETDEWEB)

    Mattox, D. L.

    1979-06-01

    The present research effort was initiated for the purpose of increasing the thermal efficiency of air heating solar collectors through identification and development of optimum design and operation criteria for solar absorber-to-air heat exchangers. Initially this effort took the form of a solar collector systems analysis to evaluate the impact of various techniques for enhancing the heat transfer between the absorber and air stream on overall thermal performance of the entire solar collector. This systems analysis resulted in the selection of solar collector designs providing ducted cooling air on the absorber shaded side as a base line. A transient heat transfer analysis of a complete solar air heating collector was used to demonstrate that an optimum absorber-to-air heat exchanger design could be provided with several interrupted fin configurations. Additional analyses were performed to establish that the maximum solar collector thermal performance to required pumping power was realized for a Reynolds number range of 1000 to 2000. This Reynolds number range was used to establish a theoretical design limit curve for maximum thermal performance versus required pumping power for all interrupted fin designs as published in the open literature. Heat and momentum transfer empirical relationships were defined for scaling the state-of-the-art high conductance fin designs identified from a compact configuration to the less compact designs needed for solar collectors.

  19. 平板式热管太阳能空气集热器热性能研究%Experimental Investigation on Thermal Performance of Flat Plate Heat Pipe Solar Air Collector

    Institute of Scientific and Technical Information of China (English)

    李世平; 向开根; 李雯; 罗会龙; 王霜

    2015-01-01

    Heat pipe has many advantages, such as higher heat transfer coefficient, lower transfer temperature-difference and a one-way heat transfer. A new flat plate heat pipe solar air collector was designed and built based on a reasonable construction. The test results indicated that the instantaneous efficiency of collector is 15.3%~74.5% under the climatic conditions of daily solar radiation being about 14.4 to19.8MJ/m2·day. Its daily average thermal efficiency is about 32.6%~53.5%with heat loss coefficient being 3.6~8.4W/(m2·K). The maximum outlet air temperature can reach 79.1℃. Compared with conventional air collectors, the new flat plate heat pipe solar air collector has higher thermal efficiency and outlet air.%热管具有传热系数高、传热温差小及单向传热等诸多优良特性。以热管为集热部件,试制了一种平板式热管太阳能空气集热器。测试结果表明,在日总太阳辐射为14.4MJ/m2~19.8MJ/m2的气候条件下,平板式热管太阳能空气集热器的瞬时集热效率在15.3%~74.5%之间,集热器出口空气温度可达79.1℃,其日平均集热效率约为32.6%~53.5%,其热损失系数约为3.6~8.4W/(m2·K)。与常规的太阳能空气集热器相比,平板式热管太阳能空气集热器具有较高的集热效率和较低的热损失系数,并且供热温度较高。

  20. 微热管阵列平板太阳能集热器中空保温层厚度优化%Optimization of hollow insulation layer for flat plate solar collector based on micro heat pipe array

    Institute of Scientific and Technical Information of China (English)

    邓月超; 赵耀华; 全贞花; 刘中良

    2015-01-01

    In this paper, a three-dimensional CFD numerical model of heat transfer and fluid flow was developed to simulate the thermal performance of the novel flat plate solar collector based on a micro heat pipe array to provide a theoretical basis for the structure improvement and optimization of the collector. The simulation of the novel collector with water flow included the CFD modeling of solar irradiation and the modes of mixed convection and radiation heat transfer between the absorber plate and glass cover, as well as the heat transfer in the circulating water inside the heat exchanger and conduction of the insulation. The fluid flow and heat transfer in the computational domain satisfied the continuity equation, the momentum equation, and the energy equation. The standardk-ε two-equation turbulence model was used in this paper. In order to predict the direct illumination energy source that results from incident solar radiation and the radiation field inside the collector, the discrete ordinate radiation model with a solar ray-tracing model was used. A commercial computational fluid dynamics program (Fluent 6.3 CFD software) was used to solve the coupled fluid flow, heat transfer, and the radiation equation. The solver used is the segregated solver. Body Force Weighted was selected as the discretization method for pressure, and the SIMPLE algorithm was used to resolve the coupling between pressure and velocity. The discretization methods for the solving of momentum, energy, radiation, and turbulence were second order upwind. The thermal performance could be achieved by simulation results under different conditions. Then, the experimental and numerical results were compared to validate the prediction of the CFD model. The results showed that the numerical results of the thermal efficiency of the novel collector were in reasonable agreement with the experimental data. The validated CFD model was used to analyze the properties of the insulation layer. First, the

  1. A reference heat source for solar collector thermal testing

    Science.gov (United States)

    Harrison, S. J.; Bernier, M. A.

    1984-12-01

    A direct-comparison reference heat source (RHS), used for testing liquid-based solar collectors, is described. A major advantage of the RHS is its capability to measure the product of mass flow and specific heat directly in the test loop. Calibration tests are performed on two reference heat sources over a range of flowrates and inlet temperatures normally encountered in flat-plate solar collector testing (10 C to 95 C). It is shown that at low flowrates (less than or equal to 0.008 kg/s), localized boiling may introduce errors if the heater power density is not reduced as well, whereas operation at flowrates greater than 0.05 kg/s reduces the temperature rise across the RHS, increasing temperature measurement uncertainty. To achieve satisfactory results with an RHS, a stable inlet temperature, good flowrate control, and regulation of the power supplied to the heater are required.

  2. Effect of Glass Thickness on Performance of Flat Plate Solar Collectors for Fruits Drying

    Directory of Open Access Journals (Sweden)

    Ramadhani Bakari

    2014-01-01

    Full Text Available This study aimed at investigating the effect of thickness of glazing material on the performance of flat plate solar collectors. Performance of solar collector is affected by glaze transmittance, absorptance, and reflectance which results into major heat losses in the system. Four solar collector models with different glass thicknesses were designed, constructed, and experimentally tested for their performances. Collectors were both oriented to northsouth direction and tilted to an angle of 10° with the ground toward north direction. The area of each collector model was 0.72 m2 with a depth of 0.15 m. Low iron (extra clear glass of thicknesses 3 mm, 4 mm, 5 mm, and 6 mm was used as glazing materials. As a control, all collector performances were analysed and compared using a glass of 5 mm thickness and then with glass of different thickness. The results showed that change in glass thickness results into variation in collector efficiency. Collector with 4 mm glass thick gave the best efficiency of 35.4% compared to 27.8% for 6 mm glass thick. However, the use of glass of 4 mm thick needs precautions in handling and during placement to the collector to avoid extra costs due to breakage.

  3. Efficiency of liquid flat-plate solar energy collector with solar tracking system

    Directory of Open Access Journals (Sweden)

    Chekerovska Marija

    2015-01-01

    Full Text Available An extensive testing programme is performed on a solar collector experimental set-up, installed on a location in Shtip (Republic of Macedonia, latitude 41º 45’ and longitude 22º 12’, in order to investigate the effect of the sun tracking system implementation on the collector efficiency. The set-up consists of two flat plate solar collectors, one with a fixed surface tilted at 30о towards the South, and the other one equipped with dual-axis rotation system. The study includes development of a 3-D mathematical model of the collectors system and a numerical simulation programme, based on the computational fluid dynamics (CFD approach. The main aim of the mathematical modelling is to provide information on conduction, convection and radiation heat transfer, so as to simulate the heat transfer performances and the energy capture capabilities of the fixed and moving collectors in various operating modes. The feasibility of the proposed method was confirmed by experimental verification, showing significant increase of the daily energy capture by the moving collector, compared to the immobile collector unit. The comparative analysis demonstrates a good agreement between the experimental and numerically predicted results at different running conditions, which is a proof that the presented CFD modelling approach can be used for further investigations of different solar collectors configurations and flow schemes.

  4. Standardized solar simulator tests of flat plate solar collectors. 1: Soltex collector with two transparent covers

    Science.gov (United States)

    Simon, F.

    1975-01-01

    A Soltex flat plate solar collector was tested with a solar simulator for inlet temperatures of 77 to 201 F, flux levels of 240 and 350 Btu/hr-sq ft, a collant flow rate of 10.5 lb/hr sq ft, and incident angles of 0 deg, 41.5 deg, and 65.2 deg. Collector performance is correlated in terms of inlet temperature, flux level, and incident angle.

  5. Low cost bare-plate solar air collector

    Energy Technology Data Exchange (ETDEWEB)

    Maag, W.L.; Wenzler, C.J.; Rom, F.E.; VanArsdale, D.R.

    1980-09-01

    The purpose of this project was to develop a low cost, bare-plate collector, determine its performance for a variety of climatic conditions, analyze the economics of this type of solar collector and evaluate specific applications. Two prototype collectors were designed, fabricated and installed into an instrumented test system. Tests were conducted for a period of five months. Results of the tests showed consistent operating efficiencies of 60% or greater with air preheat temperature uses up to 20/sup 0/F for one of the prototypes. The economic analyses indicated that an installed cost of between $5 and $10 per square foot would make this type of solar system economically viable. For the materials of construction and the type of fabrication and installation perceived, these costs for the bare-plate solar collector are believed to be attainable. Specific applications for preheating ventilation air for schools were evaluated and judged to be economically viable.

  6. Calculating the Solar Energy of a Flat Plate Collector

    Directory of Open Access Journals (Sweden)

    Ariane Rosario

    2014-09-01

    Full Text Available The amount of solar energy that could be obtained by a flat plate solar collector of one square meter dimension is calculated in three different locations: Tampa FL, Fairbanks AL, and Pontianak Indonesia, considering the varying sunset time for each day of the year. The results show that if the collectors are placed near the equator, more total energy could be obtained. In fact, by placing a solar collector in Pontianak, Indonesia 12.42% more solar energy can be obtained than by placing it in Tampa and 96.9% more solar energy than Alaska.

  7. An analytical investigation of the performance of solar collectors as nighttime heat radiators in airconditioning cycles

    Science.gov (United States)

    Jones, C. B.; Smetana, F. O.

    1979-01-01

    It was found that if the upper and lower ends of a collector were opened, large free convention currents may be set up between the collector surface and the cover glass(es) which can result in appreciable heat rejection. If the collector is so designed that both plates surfaces are exposed to convection currents when the upper and lower ends of the collector enclosure are opened, the heat rejection rate is 300 watts sq m when the plate is 13 C above ambient. This is sufficient to permit a collector array designed to provide 100 percent of the heating needs of a home to reject the accumulated daily air conditioning load during the course of a summer night. This also permits the overall energy requirements for cooling to be reduced by at least 15 percent and shift the load on the utility entirely to the nighttime hours.

  8. Flat plate solar collector design and performance. (Latest citations from the NTIS bibliographic database). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    The bibliography contains citations concerning the design and thermal efficiency of air and liquid type flat plate solar collectors. Topics include convection characteristics, methods to reduce heat loss, optical coatings, and corrosion prevention. Emphasis is on research and modeling. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  9. Flat plate solar collector design and performance. (Latest citations from the NTIS bibliographic database). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-05-01

    The bibliography contains citations concerning the design and thermal efficiency of air and liquid type flat plate solar collectors. Topics include convection characteristics, methods to reduce heat loss, optical coatings, and corrosion prevention. Emphasis is on research and modeling. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  10. Flat plate solar collector design and performance. Citations from the NTIS data base

    Science.gov (United States)

    Hundemann, A. S.

    1980-09-01

    Federally funded research on the design and thermal efficiency of air and liquid type flat plate collectors is discussed. Topic areas cover convection characteristics, methods to reduce heat loss, optical coatings, and corrosion control. Emphasis of the bibliography is on basic research studies. This updated bibliography contains 196 citations, 36 of which are new entries to the previous edition.

  11. Method of forming oxide coatings. [for solar collector heating panels

    Science.gov (United States)

    Mcdonald, G. E. (Inventor)

    1983-01-01

    This invention is concerned with an improved plating process for covering a substrate with a black metal oxide film. The invention is particularly directed to making a heating panel for a solar collector. A compound is electrodeposited from an aqueous solution containing cobalt metal salts onto a metal substrate. This compound is converted during plating into a black, highly absorbing oxide coating which contains hydrated oxides. This is achieved by the inclusion of an oxidizing agent in the plating bath. The inclusion of an oxidizing agent in the plating bath is contrary to standard electroplating practice. The hydrated oxides are converted to oxides by treatment in a hot bath, such as boiling water. An oxidizing agent may be added to the hot liquid treating bath.

  12. Standardized performance tests of collectors of solar thermal energy - A flat-plate copper collector with parallel mylar striping

    Science.gov (United States)

    Johnson, S. M.

    1976-01-01

    Basic test results are reported for a flat plate solar collector whose performance was determined in a solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and one coolant flow rate. Collector efficiency is correlated in terms of inlet temperature and flux level.

  13. Certification and verification for calmac flat plate solar collector

    Energy Technology Data Exchange (ETDEWEB)

    1978-01-27

    This document contains information used in the certification and verification of the Calmac Flat Plate Collector. Contained are such items as test procedures and results, information on materials used, Installation, Operation, and Maintenance Manuals, and other information pertaining to the verification and certification.

  14. KARAKTERISTIK PENGERINGAN CHIPS MANGGA MENGGUNAKAN KOLEKTOR SURYA KACA GANDA [Characteristics of Mango Chips Drying Using a Double Plated Solar Collector

    Directory of Open Access Journals (Sweden)

    Safrani

    2012-12-01

    Full Text Available The objectives of this research were to study the characteristics of mango chips drying using a double plated solar collector. The materials used were sliced mangoes with the thickness of 3, 6, and 8 mm. The equipments used for this research were double plated solar collector, thermocouple, digital balance, thermometer, vacuum oven, and desiccators. The research parameters included the rate of heat energy absorbed by the double plated solar collector, the heat energy losses, the efficiency of the double plated solar collector and the moisture content of the chips. The results of this study suggested that the use of double plated solar collector could increase the temperature and the amount of heat energy, thus speed up the drying process of the mango chips. The energy needed to evaporate the moisture content in mango decreased in proportion to the increase in drying time. The difference in mango chips’ thickness resulted in different decrease rate in water content until it reached a constant state. The efficiency of the double plated solar collector was 77.82%.

  15. Advances in design of air-heating collectors

    CSIR Research Space (South Africa)

    Johannsen, A

    1982-11-01

    Full Text Available Principles of the operation of air-heating collectors are discussed. The fundamental differences between the design principles of air-heating as opposed to water-heating collectors are highlighted. The main requirement is the transfer of heat from...

  16. Irreversibility analysis of non isothermal flat plate solar collectors for air heating with a dimensionless model; Analisis de las irreversibilidades en colectores solares de placas planas no isotermicos para calentamiento de aire utilizando un modelo adimensional

    Energy Technology Data Exchange (ETDEWEB)

    Bracamonte-Baran, Johane Hans; Baritto-Loreto, Miguel Leonardo [Universidad Central de Venezuela (Venezuela)]. E-mails: johanehb@gmail.com; johane.bracamonte@ucv.ve; miguel.baritto@ucv.ve

    2013-04-15

    The dimensionless model developed and validated by Baritto and Bracamonte (2012) for the thermal behavior of flat plate solar collector without glass cover is improved by adding the entropy balance equation in a dimensionless form. The model is solved for a wide range of aspect ratios and mass flow numbers. A parametric study is developed and the distribution of internal irreversibilities along the collector is analyzed. The influence of the design parameters on the entropy generation by fluid friction and heat transfer is analyzed and it is found that for certain combinations of these parameters optimal thermodynamic operation can be achieved. [Spanish] En el presente trabajo, el modelo adimensional desarrollado y validado por Baritto y Bracamonte (2012) para describir el comportamiento termico de colectores solares de placas planas sin cubierta transparente, se complementa con la ecuacion adimensional de balance de entropia para un elemento diferencial de colector solar. El modelo se resuelve para un amplio rango de valores de relaciones de aspecto y numero de flujo de masa. A partir de los resultados del modelo se desarrolla un analisis detallado de la influencia de estos parametros sobre la distribucion de irreversibilidades internas a lo largo del colector. Adicionalmente se estudia la influencia de estos parametros sobre los numeros de generacion de entropia por friccion viscosa, por transferencia de calor y total. Se encuentra que existen combinaciones de los parametros antes mencionados, para los cuales, la operacion del colector es termodinamicamente optima para numeros de flujo de masa elevados.

  17. A Dynamic Multinode Model for Component-Oriented Thermal Analysis of Flat-Plate Solar Collectors

    Directory of Open Access Journals (Sweden)

    Christoph N. Reiter

    2015-01-01

    Full Text Available A mathematical model of a flat-plate solar collector was developed on the basis of the physical principles of optics and heat transfer in order to determine collector’s component temperatures as well as collector efficiency. In contrast to many available models, the targeted use of this dynamic model is the detailed, theoretical investigation of the thermal behaviour of newly developed or adjusted collector designs on component level, for example, absorber, casing, or transparent cover. The defined model is based on a multinode network (absorber, fluid, glazing, and backside insulation containing the relevant physical equations to transfer the energy. The heat transfer network covers heat conduction, convection, and radiation. Furthermore, the collector optics is defined for the plane glazing and the absorber surface and also considers interactions between them. The model enables the variation of physical properties considering the geometric parameters and materials. Finally, the model was validated using measurement data and existing efficiency curve models. Both comparisons proved high accuracy of the developed model with deviation of up to 3% in collector efficiency and 1 K in component temperatures.

  18. DRYING WITH SOLAR COLLECTOR BY HEAT PIPE

    Directory of Open Access Journals (Sweden)

    Hikmet DOĞAN

    1999-01-01

    Full Text Available In this research, heating pipe was used in the solar collector in order to take better advantage of the solar energy. The energy obtained from the sun was transferred to the drying air by means of heating pipes and this hot air was blown on the material to be dried. The water on the material to be dried vaporised with the effect of the hot air and drying took place. Because drying took place in the shade, distant from the direct radiation effects of the sun, some of the disadvantages seen in drying outside, under the sun were eliminated. Additionally, it was observed that it took less time to dry in this method than it takes to dry under the open sun.

  19. Studies of flat-plate solar air collectors with absorber plates made of amorphous silicon photovoltaic modules; Amorphous taiyo denchi module wo shunetsuban to shita heibangata kukishiki shunetsuki no kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Sato, K.; Ito, S.; Miura, N. [Kanagawa Institute of Technology, Kanagawa (Japan)

    1996-10-27

    A light/heat hybrid air type heat collector has been developed in which heat is collected by solar cell panels. In Type 1 heat collector provided with a glass cover, two modules are connected in series and placed under a glass cover to serve as a heat collecting plate, each module built of a steel plate and two thin-film amorphous solar cells bonded to the steel plate. Air runs under the heat collecting plate. Type 2 heat collector is a Type 1 heat collector minus the glass cover. Air is taken in by a fan, runs in a vinyl chloride tube, and then through the heat collector where it is heated by the sun, and goes out at the exit. Heat collecting performance was subjected to theoretical analysis. This heat collector approximated in point of heat collection a model using a board painted black, which means that the new type functions effectively as an air-type heat collector. Operating as a photovoltaic power generator, the covered type generated approximately 20% less than the uncovered type under 800W/m{sup 2} insolation conditions. Type 1 has been in service for five months, and Type 2 for 2 months. At present, both are free of troubles such as deformation and the amorphous solar cell modules have deteriorated but a little. 4 refs., 9 figs.

  20. Status of the NASA-Lewis flat-plate collector tests with a solar simulator

    Science.gov (United States)

    Simon, F. F.

    1974-01-01

    Simulator test results of 15 collector types are reported. Collectors are given performance ratings according to their use for pool heating, hot water, absorption A/C or heating and solar Rankine machines. Collectors found to be good performers in the above categories, except for pool heating, were a black nickel coated, 2 glass collector, and a black paint 2 glass collector containing a mylar honeycomb. For pool heating, a black paint, one glass collector was found to be the best performer. Collector performance parameters of 5 collector types were determined to aid in explaining the factors that govern performance. The two factors that had the greatest effect on collector performance were the collector heat loss and the coating absorptivity.

  1. Solar Collectors

    Science.gov (United States)

    1980-01-01

    Solar Energy's solar panels are collectors for a solar energy system which provides heating for a drive-in bank in Akron, OH. Collectors were designed and manufactured by Solar Energy Products, a firm established by three former NASA employees. Company President, Frank Rom, an example of a personnel-type technology transfer, was a Research Director at Lewis Research Center, which conducts extensive solar heating and cooling research, including development and testing of high-efficiency flat-plate collectors. Rom acquired solar energy expertise which helped the company develop two types of collectors, one for use in domestic/commercial heating systems and the other for drying grain.

  2. Fixed flat plate collector with a reversible vee-trough concentrator

    Science.gov (United States)

    Selcuk, M. K.

    1976-01-01

    An asymmetrical-reversible vee-trough concentrator for use both with nonevacuated and evacuated receivers is proposed in order to improve the performance of a fixed flat plate collector. The device is capable of maintaining a year-round concentration factor of about 2 while eliminating the complications of the tilt adjustments of the collector box assembly. Efficiency improvements and cost reductions for temperatures of about 100 and 200 C are offered for the nonvacuum and vacuum tube versions, respectively. A major advantage of the vee-trough is the enhancement of the incident flux, thus extending the collection period. The vacuum collector is suitable for supplying heat to solar Rankine systems, while the nonvacuum version can be used for air conditioning purposes via an absorption air conditioner.

  3. A Process Heat Application Using Parabolic Trough Collector

    Science.gov (United States)

    Yılmaz, İbrahim Halil; Söylemez, Mehmet Sait; Hayta, Hakan; Yumrutaş, Recep

    A pilot study has been performed based on a heat process application that is designed, installed and tested at Gaziantep University to establish the technical and economic feasibility of high temperature solar-assisted cooking process. The system has been designed to be satisfying the process conditions integrated with parabolic trough solar collector (PTSC). It is primarily consists of the PTSC array, auxiliary heater, plate type heat exchanger, cooking system and water heating tanks. In the operation of the process heat application, the energy required to cook wheat (used as cooking material) has been supplied from solar energy which is transferred to heat transfer fluid (HTF) by heat exchanging units and finally discharged to water in order to produce bulgur. The performance parameters of the sub-systems and the process compatibility have been accomplished depending on the system operation. In addition that the system performance of the high temperature solar heat process has been presented and the recommendations on its improvement have been evaluated by performing an experimental study. As a result that the use of solar energy in process heat application has been projected and its contribution to economics view with respect to conventional cooking systems has been conducted.

  4. Heat Loss Calculation of Compound Honeycomb Solar Collector

    Institute of Scientific and Technical Information of China (English)

    X.S.Ge; Y.Z.Zhang; 等

    1993-01-01

    A simplified technique is described for calculating the heat loss coefficient from the absorber of the solar flat-plate collector with a combined honeycomb.The problem is treated in two ways:the coupled mode and the decoupled mode.In the analysis,the cell wall and glass cover are assumed to be specularly reflecting and diffusely emitting surfaces,while the absorber is a diffusely reflecting and emitting surface.The influences of emissivities of the absorber and the cell wall as wall as well as the aspect ratio on the heat loss coefficient are predicted.The theoretical results are compared with experimental data reported in the literature,and the agreement is good.

  5. A solar air collector with integrated latent heat thermal storage

    Science.gov (United States)

    Charvat, Pavel; Ostry, Milan; Mauder, Tomas; Klimes, Lubomir

    2012-04-01

    Simulations of the behaviour of a solar air collector with integrated latent heat thermal storage were performed. The model of the collector was created with the use of coupling between TRNSYS 17 and MATLAB. Latent heat storage (Phase Change Material - PCM) was integrated with the solar absorber. The model of the latent heat storage absorber was created in MATLAB and the model of the solar air collector itself was created in TRNSYS with the use of TYPE 56. The model of the latent heat storage absorber allows specification of the PCM properties as well as other parameters. The simulated air collector was the front and back pass collector with the absorber in the middle of the air cavity. Two variants were considered for comparison; the light-weight absorber made of sheet metal and the heat-storage absorber with the PCM. Simulations were performed for the climatic conditions of the Czech Republic (using TMY weather data).

  6. A solar air collector with integrated latent heat thermal storage

    Directory of Open Access Journals (Sweden)

    Klimes Lubomir

    2012-04-01

    Full Text Available Simulations of the behaviour of a solar air collector with integrated latent heat thermal storage were performed. The model of the collector was created with the use of coupling between TRNSYS 17 and MATLAB. Latent heat storage (Phase Change Material - PCM was integrated with the solar absorber. The model of the latent heat storage absorber was created in MATLAB and the model of the solar air collector itself was created in TRNSYS with the use of TYPE 56. The model of the latent heat storage absorber allows specification of the PCM properties as well as other parameters. The simulated air collector was the front and back pass collector with the absorber in the middle of the air cavity. Two variants were considered for comparison; the light-weight absorber made of sheet metal and the heat-storage absorber with the PCM. Simulations were performed for the climatic conditions of the Czech Republic (using TMY weather data.

  7. Influence of wire-coil inserts on the thermo-hydraulic performance of a flat-plate solar collector

    Science.gov (United States)

    Herrero Martín, R.; García, A.; Pérez-García, J.

    2012-11-01

    Enhancement techniques can be applied to flat-plate liquid solar collectors towards more compact and efficient designs. For the typical operating mass flow rates in flat-plate solar collectors, the most suitable technique is inserted devices. Based on previous studies from the authors, wire coils were selected for enhancing heat transfer. This type of inserted device provides better results in laminar, transitional and low turbulence fluid flow regimes. To test the enhanced solar collector and compare with a standard one, an experimental side-by-side solar collector test bed was designed and constructed. The testing set up was fully designed following the requirements of EN12975-2 and allow us to accomplish performance tests under the same operating conditions (mass flow rate, inlet fluid temperature and weather conditions). This work presents the thermal efficiency curves of a commercial and an enhanced solar collector, for the standardized mass flow rate per unit of absorber area of 0.02 kg/sm2 (in useful engineering units 144 kg/h for water as working fluid and 2 m2 flat-plate solar collector of absorber area). The enhanced collector was modified inserting spiral wire coils of dimensionless pitch p/D = 1 and wire-diameter e/D = 0.0717. The friction factor per tube has been computed from the overall pressure drop tests across the solar collectors. The thermal efficiency curves of both solar collectors, a standard and an enhanced collector, are presented. The enhanced solar collector increases the thermal efficiency by 15%. To account for the overall enhancement a modified performance evaluation criterion (R3m) is proposed. The maximum value encountered reaches 1.105 which represents an increase in useful power of 10.5% for the same pumping power consumption.

  8. Theoretical analysis of solar thermal collector and flat plate bottom reflector with a gap between them

    OpenAIRE

    Hiroshi Tanaka

    2015-01-01

    Augmentation of solar radiation absorbed on a flat plate solar thermal collector by a flat plate bottom reflector was numerically determined when there was a gap between the collector and reflector. The inclination of both the collector and reflector was assumed to be adjustable according to the season. A mirror-symmetric plane of the collector to the reflector was introduced, and a graphical model was proposed to calculate the amount of solar radiation reflected by the reflector and then abs...

  9. A solar air collector with integrated latent heat thermal storage

    OpenAIRE

    Klimes Lubomir; Mauder Tomas; Ostry Milan; Charvat Pavel

    2012-01-01

    Simulations of the behaviour of a solar air collector with integrated latent heat thermal storage were performed. The model of the collector was created with the use of coupling between TRNSYS 17 and MATLAB. Latent heat storage (Phase Change Material - PCM) was integrated with the solar absorber. The model of the latent heat storage absorber was created in MATLAB and the model of the solar air collector itself was created in TRNSYS with the use of TYPE 56. The model of the latent heat storage...

  10. Flat plate collector with external reflectors (RefleC). Experiences withthe development; Flachkollektor mit externen Reflektoren (RefleC). Entwicklungserfahrungen

    Energy Technology Data Exchange (ETDEWEB)

    Hess, S.; Oliva, A.; Di Lauro, P.; Klemke, M.; Hermann, M.; Stryi-Hipp, G. [Fraunhofer-Institut fuer Solare Energiesysteme ISE, Freiburg (Germany); Kallwellis, V.; Kramp, G.; Eisenmann, W. [Wagner und Co. Solartechnik GmbH, Coelbe (Germany); Hanby, V. [DMU Leicester (United Kingdom). Inst. of Energy and Sustainable Development

    2010-07-01

    In cooperation with the Fraunhofer Institute for Solar Energy Systems (Freiburg, Federal Republic of Germany), the company Wagner and Co. Solar Technology (Coelbe, Federal Republic of Germany) developed a stationary concentrated, double-covered flat plate collector with an external reflector for generating process heat up to a temperature of 150 C. This prototype has a half-CPC reflector which is approximated by three flat segments. The reflectors use the distance between the collectors and serves simultaneously as a supporting structure. The collector is designed so that the aperture is not shaded. The authors of the contribution under consideration present the WKI curves and the IAM curves as a test pattern as well as a simulation of the annual energy yield. According to the simulation, the Reflec-collector has an annual energy yield which is greater by 64 % than that of the double-covered base-collector.

  11. Investigation of Thermal Performance of Flat Plate and Evacuated Tubular Solar Collectors According to a New Dynamic Test Method

    DEFF Research Database (Denmark)

    Kong, Weiqiang; Wang, Zhifeng; Fan, Jianhua;

    2012-01-01

    obtain fluid thermal capacitance in data processing. Then theoretical analysis and experimental verification are carried out to investigate influencing factors of obtaining accurate and stable second order term. A flat plate and ETC solar collector are compared using both the new dynamic method......A new dynamic test method is introduced. This so called improved transfer function method features on two new collector parameters. One is time term which can indicate solar collector's inner heat transfer ability and the other is a second order term of collector mean fluid temperature which can...... and a standard method. The results show that the improved function method can accurately and robustly estimate these two kinds of solar collectors....

  12. An analytical investigation of the performance of solar collectors as nighttime heat radiators in airconditioning cycles. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Jones, C.B.; Smetana, F.O.

    1979-03-01

    It was found that if the upper and lower ends of a collector were opened, large free convention currents may be set up between the collector surface and the cover glass(es) which can result in appreciable heat rejection. If the collector is so designed that both plates surfaces are exposed to convection currents when the upper and lower ends of the collector enclosure are opened, the heat rejection rate is 300 watts sq m when the plate is 13 C above ambient. This is sufficient to permit a collector array designed to provide 100 percent of the heating needs of a home to reject the accumulated daily air conditioning load during the course of a summer night. This also permits the overall energy requirements for cooling to be reduced by at least 15 percent and shift the load on the utility entirely to the nighttime hours.

  13. Investigation of methods to transfer heat from solar liquid-heating collectors to heat storage tanks

    Energy Technology Data Exchange (ETDEWEB)

    de Winter, F.

    1976-01-01

    A number of possible solutions to the problems of corrosion and freezing in flat-plate collectors are listed and discussed briefly. Specific considerations involved in the choice and definition of these solutions are discussed in greater detail. (MHR)

  14. The Effect of the Configuration of the Absorber on the Performance of Flat Plate Thermal Collector

    OpenAIRE

    Yan, Moyu; Qu, Ming; Peng, Steve

    2016-01-01

    In this study, a numerical thermal analysis for a new designed flat plate thermal collector was conducted through modeling. The new flat plate thermal collector has ellipse shaped tubes inside a wavy shaped absorber, which is made of stainless steel. For the comparison, the conventional flat plate thermal collector with circular copper tubes served as a base case was also modeled. Hottel-Whillier equations were utilized to formulate thermal networks for both models developed in Engineering Eq...

  15. Experimental investigation of forced-convection in a finned rhombic tube of the flat-plate solar collectors

    DEFF Research Database (Denmark)

    Taherian, Hessam; Yazdanshenas, Eshagh

    2006-01-01

    Due to scarcity of literature on forced-convection heat transfer in a solar collector with rhombic cross-section absorbing tubes, a series of experiments was arranged and conducted to determine heat transfer coefficient. In this study, a typical rhombic cross-section finned tube of flat......-plate collectors used as the test section. Two correlations were proposed for the Nusselt number as a function of the Reynolds number and the Prandtl number based on hydraulic diameter for various heat fluxes. The temperature distribution along the finned tube for the fluid and the wall were also illustrated....

  16. Standarized performance tests of collectors of solar thermal energy: A steel flat-plate collector with two transparent covers and a proprietary coating

    Science.gov (United States)

    1976-01-01

    Basic test results of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator are given. The collector was tested over ranges of inlet temperature and flux level.

  17. Performance of a Solar Heating System with Photovoltaic Thermal Hybrid Collectors and Heat Pump

    DEFF Research Database (Denmark)

    Dannemand, Mark; Furbo, Simon; Perers, Bengt

    2017-01-01

    . When the solar collectors are unable to supply the heat demand an auxiliary heat source is used. Heat pumps can generate this heat. Liquid/water heat pumps have better performance than air/water heat pumps in cold climates but requires installation of a tubing system for the cold side of the heat pump....... The tubes are typically placed in the ground, requires a significant land area and increase the installation cost. A new system design of a solar heating system with two storage tanks and a liquid/water heat pump is presented. The system consists of PVT collectors that generate both heat and electricity....... Heat from the collectors is transferred to a domestic hot water storage tank or to a cold storage tank, which is used as the source for the heat pump. When the heat pump charges the warm storage tank, heat is extracted from the cold storage tank, which then can be reheated by the PVT collectors...

  18. Theoretical analysis of solar thermal collector and flat plate bottom reflector with a gap between them

    Directory of Open Access Journals (Sweden)

    Hiroshi Tanaka

    2015-11-01

    Full Text Available Augmentation of solar radiation absorbed on a flat plate solar thermal collector by a flat plate bottom reflector was numerically determined when there was a gap between the collector and reflector. The inclination of both the collector and reflector was assumed to be adjustable according to the season. A mirror-symmetric plane of the collector to the reflector was introduced, and a graphical model was proposed to calculate the amount of solar radiation reflected by the reflector and then absorbed on the collector. The performance was analyzed for three typical days at a latitude of 30°N. Solar radiation absorbed on the collector can be increased by the bottom reflector even if there is a gap between the collector and reflector. The optimum inclinations of both the collector and reflector are almost the same while the gap length is less than the lengths of the collector and reflector. However, the range of inclination of the reflector that can increase the solar radiation absorbed on the collector decreases with an increase in gap length, and the solar radiation absorbed on the collector rapidly decreased with an increase in the gap length when the reflector and/or collector were not set at a proper angle.

  19. Comparative performance of twenty-three types of flat plate solar energy collectors

    Science.gov (United States)

    Simon, F. F.

    1975-01-01

    Report compares efficiencies of 23 solar collectors for four different purposes: operating a Rankine-cycle engine, heating or absorption air conditioning, heating hot water, and heating a swimming pool.

  20. High performance collectors

    Science.gov (United States)

    Ogawa, H.; Hozumi, S.; Mitsumata, T.; Yoshino, K.; Aso, S.; Ebisu, K.

    1983-04-01

    Materials and structures used for flat plate solar collectors and evacuated tubular collectors were examined relative to their overall performance to project effectiveness for building heating and cooling and the feasibility of use for generating industrial process heat. Thermal efficiencies were calculated for black paint single glazed, selective surface single glazed, and selective surface double glazed flat plate collectors. The efficiencies of a single tube and central tube accompanied by two side tube collectors were also studied. Techniques for extending the lifetimes of the collectors were defined. The selective surface collectors proved to have a performance superior to other collectors in terms of the average annual energy delivered. Addition of a black chrome-coated fin system to the evacuated collectors produced significant collection efficiency increases.

  1. Standardized performance tests of collectors of solar thermal energy-a flat-plate collector with a single-tube serpentine flow distribution

    Science.gov (United States)

    Johnson, S.

    1976-01-01

    This preliminary data report gives basic test results of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and coolant flow rates. Collector efficienty is correlated in terms of inlet temperature and flux level.

  2. Solar assisted heat pump on air collectors: A simulation tool

    Energy Technology Data Exchange (ETDEWEB)

    Karagiorgas, Michalis; Galatis, Kostas; Tsagouri, Manolis [Department of Mechanical Engineering Educators, ASPETE, N. Iraklio, GR 14121 (Greece); Tsoutsos, Theocharis [Environmental Engineering Dept., Technical University of Crete, Technical University Campus, GR 73100, Chania (Greece); Botzios-Valaskakis, Aristotelis [Centre for Renewable Energy Sources (CRES), 19th km Marathon Ave., GR 19001, Pikermi (Greece)

    2010-01-15

    The heating system of the bioclimatic building of the Greek National Centre for Renewable Energy Sources (CRES) comprises two heating plants: the first one includes an air source heat pump, Solar Air Collectors (SACs) and a heat distribution system (comprising a fan coil unit network); the second one is, mainly, a geothermal heat pump unit to cover the ground floor thermal needs. The SAC configuration as well as the fraction of the building heating load covered by the heating plant are assessed in two operation modes; the direct (hot air from the collectors is supplied directly to the heated space) and the indirect mode (warm air from the SAC or its mixture with ambient air is not supplied directly to the heated space but indirectly into the evaporator of the air source heat pump). The technique of the indirect mode of heating aims at maximizing the efficiency of the SAC, saving electrical power consumed by the compressor of the heat pump, and therefore, at optimizing the coefficient of performance (COP) of the heat pump due to the increased intake of ambient thermal energy by means of the SAC. Results are given for three research objectives: assessment of the heat pump efficiency whether in direct or indirect heating mode; Assessment of the overall heating plant efficiency on a daily or hourly basis; Assessment of the credibility of the suggested simulation model TSAGAIR by comparing its results with the TRNSYS ones. (author)

  3. Design and Development of ZigBee Based Instantaneous Flat-plate Collector Efficiency Measurement System

    Science.gov (United States)

    Vairamani, K.; Venkatesh, K. Arun; Mathivanan, N.

    2011-01-01

    Computing the efficiency of flat-plate collector is vital in solar thermal system testing. This paper presents the design of ZigBee enabled data acquisition system for instantaneous flat-plate collector efficiency calculation. It involves measurement of parameters like inlet and outlet fluid temperatures, ambient temperature and solar radiation intensity. The designed system has a base station and a sensor node. ZigBee wireless communication protocol is used for communication between the base station and the sensor node for wireless data acquisition. The wireless sensor node which is mounted over the collector plate includes the necessary sensors and associated signal-conditioners. An application program has been developed on LabVIEW platform for data acquisition, processing and analysis and is executed in base station PC. Instantaneous flat-plate collector efficiency is computed and reported.

  4. Comparison of the effects of Al2O3 and CuO nanoparticles on the performance of a solar flat-plate collector

    Science.gov (United States)

    Munuswamy, Dinesh Babu; Madhavan, Venkata Ramanan; Mohan, Mukunthan

    2015-12-01

    To improve the efficiency of solar flat-plate collectors further, a study had been carried out wherein the conventional working fluid was replaced by nanofluids. A 25-L/day solar flat-plate water heater with collector area of 0.5 {m}^2 has been designed and fabricated. The thermosyphon system of the solar water heater was monitored at 15 locations using T-type thermocouples. Alumina and CuO nanoparticles were synthesized and characterized using Brunauer-Emmett-Teller and X-ray diffraction techniques and dispersed using ultrasonic mechanism. To stabilize the system at an optimum level, the collector is operated with volume fractions of 0.2% and 0.4% of synthesized Al2O3 and CuO nanoparticles mixed with distilled water and used in the solar flat-plate collector. The temperature profile was compared with different volume fractions of the nanoparticles in the flowing medium. Enhanced heat transfer was observed in the solar flat-plate collector using nanoparticles, and hence, it is inferred that addition of nanoparticles improves the efficiency of the solar water heaters. This paper details the temperature profile observed in the collectors, variation of insolation over the day, and change in efficiency both on the primary side (collector) and on the secondary side (storage tank) of the solar water heater.

  5. Heat transfer characteristics in the channel of a finned absorber solar collector; Caracteristicas da transferencia de calor no canal de um coletor solar de absorvedor aletado

    Energy Technology Data Exchange (ETDEWEB)

    Saboya, Sergio Mourao [Centro Tecnico Aeroespacial, Sao Jose dos Campos, SP (Brazil). Inst. Tecnologico de Aeronautica; Saboya, Francisco Eduardo Mourao [Universidade Federal Fluminense, Niteroi, RJ (Brazil)]. E-mails: saboya@mec.ita.cta.br; fsaboya@mec.uff.br

    2000-07-01

    Finned absorber solar collectors are devices in which plates (fins) are fixed perpendicularly to the absorber plate. The purpose of these fins is to cause the so called 'cavity effect', lowering the collector losses. This paper studies the heat transfer that occurs in the collector channel. This analysis is done using the efficiency of the collector, which is calculated solving the system of equations that govern the collector thermal behavior, and the computation of the convection heat transfer between the fluid flowing in the channel and the absorber plate. This analysis allows the calculation of design parameters such as mass flow rate and exit bulk temperature of the fluid. (author)

  6. A Numerical Study on the Performance of an Open-type Flat-plate Solar Collector

    OpenAIRE

    Song, Baoyin; Inaba, Hideo; Horibe, Akihiko

    1999-01-01

    A set mathematical models was developed for predicting the performance of an open-type flat-plate solar collector, and solved numerically through an implicit difference method. The effects of various parameters on the absorption of solar energy for the collector were investigated. The results showed that the solar energy absorptance of the open-type flat-plate collector was relatively high especially for the region where the weather was humid and hot, and there were an optimum length and an o...

  7. Design and Development of Prototype Cylindrical Parabolic Solar Collector for Water Heating Application

    Directory of Open Access Journals (Sweden)

    Hrushikesh Bhujangrao Kulkarni

    2016-02-01

    Full Text Available Concentrating collectors absorbs solar energy and convert it into heat for generating hot water, steam at required temperature, which can be further used for solar thermal applications. The developing countries like India where solar energy is abundantly available; there is need to develop technology for harnessing solar energy for power production, but the main problem associated with concentrating solar power technology is the high cost of installation and low output efficiency. To solve this problem, a prototype cylindrical parabolic solar collector having aperture area of 1.89 m2 is designed and developed using low cost highly reflecting and absorbing material to reduce initial cost of project and improve thermal efficiency. ASHRAE Standard 93, 1986 was used to evaluate the thermal performance and it was observed that this system can generate hot water at an average temperature of 500C per day with an average efficiency of 49% which is considerable higher than flat plate solar collectors. Hot water produced by this system can be useful for domestic, agricultural, industrial process heat applications.Article History: Received Sept 19, 2015; Received in revised form Dec 23, 2015; Accepted February 2, 2016; Available online How to Cite This Article: Bhujangrao, K.H. (2016. Design and Development of Prototype Cylindrical Parabolic Solar Collector for Water Heating Application. International Journal of Renewable Energy Development, 5(1, 49-55 http://dx.doi.org/10.14710/ijred.5.1.49-55 

  8. Multiple-effect diffusion solar still coupled with a vacuum-tube collector and heat pipe

    KAUST Repository

    Chong, Tze-Ling

    2014-08-01

    The present study develops a multiple-effect diffusion solar still (MEDS) with a bended-plate design in multiple-effect diffusion unit (MDU) to solve the peel-off problem of wick material. The MDU is coupled with a vacuum-tube solar collector to produce a high temperature gradient for high productivity. A heat pipe is used to transfer the solar heat to the MDU. A prototype MEDS-1L was built and tested outdoors. Four performance indexes are proposed for the performance evaluation of MEDS, including daily pure water production per unit area of glass cover, solar absorber, and evaporating surface (Mcov, Msol, Mevp, respectively), and solar distillation efficiency Rcov. The outdoor test results of MEDS-1L show that the solar collector supply temperature Th reaches 100°C at solar radiation 800Wm-2. The highest Mcov is 23.9kgm-2d-1 which is about 29% higher than the basin-type MEDS [11]. The highest value is 25.9kgm-2d-1 for Msol and 2.79kgm-2d-1 for Mevp. The measured Rcov is 1.5-2.44, higher than the basin-type MEDS (1.45-1.88). The Mcov, Msol, Mevp and Rcov of MEDS-1L are all higher than the theoretical calculation of a MEDS with a flat-plate solar collector coupled with a heat pipe (MEDS-FHP) [17].© 2014 Elsevier B.V.

  9. Exergy efficiency analysis of a flat plate solar collector using graphene based nanofluid

    Science.gov (United States)

    Said, Z.; Alim, M. A.; Janajreh, Isam

    2015-10-01

    The thermal efficiency of a flat plate solar thermal collector is largely affected by the thermal conductivity of the fluid used. In this paper, we theoretically analyzed the heat transfer performance, the entropy generation rate, and the exergy efficiency of the two different graphene based nanofluids (graphene/Acetone and graphene/water). From the analyses, it is revealed that by inserting a small amount of graphene nanoparticles in water, exergy efficiency could be enhanced by 21%, comparing to conventional fluids and entropy generation is decreased by 4%. However, the graphene/water nanofluid shows a lower entropy generation. This characteristic suggests that graphene/water nanofluid is a better candidate for flat solar thermal application.

  10. Solar thermal collectors

    Science.gov (United States)

    Aranovitch, E.

    Thermal processes in solar flat plate collectors are described and evaluated analytically, and numerical models are presented for evaluating the performance of various designs. A flat plate collector consists of a black absorber plate which transfers absorbed heat to a fluid, a cover which limits thermal losses, and insulation to prevent backlosses. Calculated efficiencies for the collectors depend on the radiation absorbed, as well as IR losses due to natural convection, conduction, and radiation out of the collector. Formulations for the global emittance and heat transfer, as well as losses and their dependence on the Nusselt number and Grashof number are defined. Consideration is given to radiation transmission through transparent covers and Fresnel reflections at interfaces in the cover material. Finally, the performance coefficients for double-glazed and selective surface flat plate collectors are examined.

  11. Thermal performance of evacuated tube heat pipe solar collector

    Science.gov (United States)

    Putra, Nandy; Kristian, M. R.; David, R.; Haliansyah, K.; Ariantara, Bambang

    2016-06-01

    The high fossil energy consumption not only causes the scarcity of energy but also raises problems of global warming. Increasing needs of fossil fuel could be reduced through the utilization of solar energy by using solar collectors. Indonesia has the abundant potential for solar energy, but non-renewable energy sources still dominate energy consumption. With heat pipe as passive heat transfer device, evacuated tube solar collector is expected to heat up water for industrial and home usage without external power supply needed to circulate water inside the solar collector. This research was conducted to determine the performance of heat pipe-based evacuated tube solar collector as solar water heater experimentally. The experiments were carried out using stainless steel screen mesh as a wick material, and water and Al2O3-water 0.1% nanofluid as working fluid, and applying inclination angles of 0°, 15°, 30°, and 45°. To analyze the heat absorbed and transferred by the prototype, water at 30°C was circulated through the condenser. A 150 Watt halogen lamp was used as sun simulator, and the prototype was covered by an insulation box to obtain a steady state condition with a minimum affection of ambient changes. Experimental results show that the usage of Al2O3-water 0.1% nanofluid at 30° inclination angle provides the highest thermal performance, which gives efficiency as high as 0.196 and thermal resistance as low as 5.32 °C/W. The use of nanofluid as working fluid enhances thermal performance due to high thermal conductivity of the working fluid. The increase of the inclination angle plays a role in the drainage of the condensate to the evaporator that leads to higher thermal performance until the optimal inclination angle is reached.

  12. Comparison under a simulated sun of two black-nickel-coated flat-plate solar collectors with a nonselective black-paint-coated collector

    Science.gov (United States)

    Simon, F. F.

    1975-01-01

    A performance evaluation was made of two, black nickel coated, flat plate solar collectors. Collector performance was determined under a simulated sun for a wide range of inlet temperatures, including the temperature required for solar powered absorption air conditioning. For a basis of comparison a performance test was made on a traditional, two glass, nonselective, black paint coated, flat plate collector. Performance curves and performance parameters are presented to point out the importance of the design variables which determine an efficient collector. A black nickel coated collector was found to be a good performer at the conditions expected for solar powered absorption air conditioning. This collector attained a thermal efficiency of 50 percent at an inlet temperature of 366 K (200 F) and an incident flux of 946 watts/sq m (300 Btu/hr-sq ft).

  13. VALIDATION OF SIMULATION MODELS FOR DIFFERENTLY DESIGNED HEAT-PIPE EVACUATED TUBULAR COLLECTORS

    DEFF Research Database (Denmark)

    Fan, Jianhua; Dragsted, Janne; Furbo, Simon

    2007-01-01

    Differently designed heat-pipe evacuated tubular collectors have been investigated theoretically and experimentally. The theoretical work has included development of two TRNSYS [1] simulation models for heat-pipe evacuated tubular collectors utilizing solar radiation from all directions. One model...... coating on both sides. The input to the models is thus not a simple collector efficiency expression but the actual collector geometry. In this study, the TRNSYS models are validated with measurements for four differently designed heat-pipe evacuated tubular collectors. The collectors are produced...... cases, a good degree of similarity between measured and calculated results is found. With these validated models detailed parameter analyses and collector design optimization are now possible. Key words: Evacuated tubular collector, Heat pipe, Thermal performance, TRNSYS simulation....

  14. Craft-Joule Project: Stagnation proof transparently insulated flat plate solar collector (static)

    Energy Technology Data Exchange (ETDEWEB)

    Oliva, A; Cadafalch, J; Perez-Segarra, C.D. [Universitat Politecnica de Catalunya, Barcelona (Spain)] (and others)

    2000-07-01

    The STATIC (STAgnation proof Transparently Insulated flat plate Solar Collector) project is a Craft-Joule Project within the framework of the Non Nuclear Energy Programme Joule III coordinated by the Centre Technologic de Transferencia de Calor (CTTC). The core group of SMEs involved in the project has its main economical activity in the field of solar thermal systems at low temperature level (domestic hot water, solar heating, etc.). Beyond this, a large application potential exists for solar heating at medium temperature level (from 80 to 160 Celsius degrees) : industrial process heat, solar cooling and air conditioning, solar drying , distillation and desalination. Three of the four SME proposers are located in Southern Europe and in the Caribean, where a continuos increase of the demand for air conditioning and cooling has been demonstrated in the last years. The recent development of flat plate solar collectors with honeycomb-type transparent insulation cover has shown that this type of collectors can become a low cost alternative to evacuated tube and high concentrating CPC collectors in the medium temperature range from 80 to 160 Celsius degrees. With the expected reduction of collector cost, that forms 30%-50% of total system cost, a decisive break-through of solar thermal systems using heat in the medium temperature range can be achieved. The feasibility and good performance of these solar collectors has been proved in several prototypes. Nevertheless, up to now no commercial products are available. In order to reach this, the following developments of new concepts are necessary and are being carried out within this project: solution of the problem of overheating: development of collector versions for different working temperatures: optimization of the design with the support of high level numerical simulation. Several prototypes of the new solar collectors are being tested. System tests will also be carried or for two test arrays of optimized collector

  15. Application of Induction Heating for Brazing Parts of Solar Collectors

    Directory of Open Access Journals (Sweden)

    Kristína Demianová

    2012-01-01

    Full Text Available This paper reports on the application of induction heating for brazing parts of solar collectors made of Al alloys. The tube-flange joint is a part of the collecting pipe of a solar collector. The main task was to design an induction coil for this type of joint, and to select the optimum brazing parameters. Brazing was performed with AlSi12 brazing alloy, and corrosive and non-corrosive flux types were also applied. The optimum brazing parameters were determined on the basis of testing the fabricated brazed joints by visual inspection, by leakage tests, and by macro- and micro-analysis of the joint boundary. The following conditions can be considered to be the best for brazing Al materials: power 2.69 kW,brazing time 24 s, flux BrazeTec F32/80.

  16. Experimental study on flat plate air solar collector using a thin sand layer

    Science.gov (United States)

    Lati, Moukhtar; Boughali, Slimane; Bouguettaia, Hamza; Mennouche, Djamel; Bechki, Djamel

    2016-07-01

    A flat plate air solar collector was constructed in the laboratory of New and Renewable Energy in Arid Zones LENREZA, Ouargla University-South East Algeria. The absorber of the flat plate air solar collector was laminated with a thin layer of local sand. This acted as a thermal storage system (packed bed) with a collecting area of 2.15 m2 (0.86 m × 2.5 m). It was noticed that the solar heater integrated with the thermal storage material delivered comparatively higher temperatures; thus, giving a better efficiency than the air heater without the thermal storage system.

  17. Experimental Study on Performance of a Box Solar Cooker with Flat Plate Collector to Boil Water

    Science.gov (United States)

    Sitepu, T.; Gunawan, S.; Nasution, D. M.; Ambarita, H.; Siregar, R. E. T.; Ronowikarto, A. D.

    2017-03-01

    In this study, a flat plate type solar cooker is tested by exposing in solar irradiation. The objective is to examine the performance of solar cooker in boiling water. The solar cooker is a box type with collector area and height are 100 × 100 cm and 40 cm, respectively. Vessel for water is made of aluminum plate with diameter and height of 22 cm and 15 cm. The experiments are performed by varying mass of the water. It is 2 kg and 4 kg, respectively. Every experiment starts from 10:00 AM until the boiling temperature is reached. The parameters measured are radiance intensity, ambient and solar box cooker temperatures, and wind speed. The results show that the duration of water heating up to 100°C with water mass 2 kg within 2 hours 45 minutes and water mass 4 kg within 3 hours 17 minutes. The maximum temperatur of solar box cooker is 117°C at 12:56 PM and maximum efficiency is 46.30%. The main conclusion can be drawn here is that a simple solar box cooker can be used to boil water.

  18. Potential of size reduction of flat-plate solar collectors when applying MWCNT nanofluid

    Science.gov (United States)

    Faizal, M.; Saidur, R.; Mekhilef, S.

    2013-06-01

    Flat-plate solar collector is the most popular type of collector for hot water system to replace gas or electric heater. Solar thermal energy source is clean and infinite to replace fossil fuel source that is declining and harmful to the environment. However, current solar technology is still expensive, low in efficiency and takes up a lot of space. One effective way to increase the efficiency is by applying high conductivity fluid as nanofluid. This paper analyzes the potential of size reduction of solar collector when MWCNT nanofluid is used as absorbing medium. The analysis is based on different mass flow rate, nanoparticles mass fraction, and presence of surfactant in the fluid. For the same output temperature, it can be observed that the collector's size can be reduced up to 37% of its original size when applying MWCNT nanofluid as the working fluid and thus can reduce the overall cost of the system.

  19. A simulation modeling for optimization of flat plate collector design in Riyadh, Saudi Arabia

    Energy Technology Data Exchange (ETDEWEB)

    Al Ajlan, S.A.; Al Faris, H.; Khonkar, H. [King Abdulaziz City for Science and Technology, Riyadh (Saudi Arabia). Energy Research Inst.

    2003-07-01

    A simulation of forced convection solar heated water system is presented. A computer program is developed consisting of independent subroutines, capable of handling the variation of the collector tube diameter, tube spacing, ambient conditions, material thermal properties, collector and system design optimization. The meteorological data of Riyadh were used as the input in the program to simulate the performance of the collector system. The output of the program is analyzed to optimize the system design in the Riyadh region. The results of the simulations are compared with experimental data. There is a good agreement between the predicted and measured values.(author)

  20. Performance of double -pass solar collector with CPC and fins for heat transfer enhancement

    Science.gov (United States)

    Alfegi, Ebrahim M. A.; Abosbaia, Alhadi A. S.; Mezughi, Khaled M. A.; Sopian, Kamaruzzaman

    2013-06-01

    The temperature of photovoltaic modules increases when it absorbs solar radiation, causing a decrease in efficiency. This undesirable effect can be partially avoided by applying a heat recovery unit with fluid circulation (air or water) with the photovoltaic module. Such unit is called photovoltaic / thermal collector (pv/t) or hybrid (pv/t). In this unit, photovoltaic cells were pasted directly on the flat plate absorber. An experimental study of a solar air heater with photovoltaic cell located at the absorber with fins and compound parabolic collector for heat transfer enhancement and increasing the number of reflection on the cells have been conducted. The performance of the photovoltaic, thermal, and combined pv/t collector over range of operating conditions and the results was discussed. Results at solar irradiance of 500 W/m2 show that the combined pv/t efficiency is increasing from 37.28 % to 81.41 % at mass flow rates various from 0.029 to 0.436 kg/s.

  1. Hot-air flat-plate solar collector-design package

    Science.gov (United States)

    1979-01-01

    Report contains design data, performance specifications, and drawings for hot-air flat-plate solar-energy collector. Evaluation consists of tests on thermal performance time constance, and incidence angle modifier test. Results are presented in table and graph form and are analyzed in detail.

  2. Hot-air flat-plate solar collector-design package

    Science.gov (United States)

    1979-01-01

    Report contains design data, performance specifications, and drawings for hot-air flat-plate solar-energy collector. Evaluation consists of tests on thermal performance time constance, and incidence angle modifier test. Results are presented in table and graph form and are analyzed in detail.

  3. Evaluation of All-Day-Efficiency for selected flat plate and evacuated tube collectors

    Science.gov (United States)

    1981-01-01

    An evaluation of all day efficiency for selected flat plate and evacuated tube collectors is presented. Computations are based on a modified version of the NBSIR 78-1305A procedure for all day efficiency. The ASHMET and NOAA data bases for solar insolation are discussed. Details of the algorithm used to convert total (global) horizontal radiation to the collector tilt plane of the selected sites are given along with tables and graphs which show the results of the tests performed during this evaluation.

  4. Building Space Heating with a Solar-Assisted Heat Pump Using Roof-Integrated Solar Collectors

    Directory of Open Access Journals (Sweden)

    Zhiyong Yang

    2011-03-01

    Full Text Available A solar assisted heat pump (SAHP system was designed by using a roof-integrated solar collector as the evaporator, and then it was demonstrated to provide space heating for a villa in Tianjin, China. A building energy simulation tool was used to predict the space heating load and a three dimensional theoretical model was established to analyze the heat collection performance of the solar roof collector. A floor radiant heating unit was used to decrease the energy demand. The measurement results during the winter test period show that the system can provide a comfortable living space in winter, when the room temperature averaged 18.9 °C. The average COP of the heat pump system is 2.97 and with a maximum around 4.16.

  5. Solar tests of aperture plate materials for solar thermal dish collectors

    Science.gov (United States)

    Jaffe, L. D.

    1984-11-01

    If a malfunction occurs in a solar thermal point-focus distributed receiver power plant while a concentrator is pointed at the sun, motion of the concentrator may stop. As the sun moves relative to the earth, the spot of concentrated sunlight then slowly walks off the receiver aperture, across the receiver face plate, and perhaps across adjacent portions of the concentrator. Intense local heating by the concentrated sunlight may damage or destroy these parts. The behavior of various materials under conditions simulating walk-off of a parabolic dish solar collector were evaluated. Each test consisted of exposure to concentrated sunlight at a peak flux density of about 7000 kW/square meter for 15 minutes. Types of materials tested included graphite, silicon carbide, silica, various silicates, alumina, zirconia, aluminum, copper, steel, and polytetrafluroethylene. The only material that neither cracked nor melted was grade G-90 graphite. Grade CS graphite, a lower cost commercial grade, cracked half-way across, but did not fail apart. Both of these grades are medium-grain extruded graphites. A graphite cloth (graphitized polyacrylonitrile) showed fair performance when tested as a single thin ply; it might be useful as a multi-ply assembly. High purity slipcast silica showed some promise also.

  6. Solar tests of aperture plate materials for solar thermal dish collectors

    Science.gov (United States)

    Jaffe, L. D.

    1984-01-01

    If a malfunction occurs in a solar thermal point-focus distributed receiver power plant while a concentrator is pointed at the sun, motion of the concentrator may stop. As the sun moves relative to the earth, the spot of concentrated sunlight then slowly walks off the receiver aperture, across the receiver face plate, and perhaps across adjacent portions of the concentrator. Intense local heating by the concentrated sunlight may damage or destroy these parts. The behavior of various materials under conditions simulating walk-off of a parabolic dish solar collector were evaluated. Each test consisted of exposure to concentrated sunlight at a peak flux density of about 7000 kW/square meter for 15 minutes. Types of materials tested included graphite, silicon carbide, silica, various silicates, alumina, zirconia, aluminum, copper, steel, and polytetrafluroethylene. The only material that neither cracked nor melted was grade G-90 graphite. Grade CS graphite, a lower cost commercial grade, cracked half-way across, but did not fail apart. Both of these grades are medium-grain extruded graphites. A graphite cloth (graphitized polyacrylonitrile) showed fair performance when tested as a single thin ply; it might be useful as a multi-ply assembly. High purity slipcast silica showed some promise also.

  7. VALIDATION OF SIMULATION MODELS FOR DIFFERENTLY DESIGNED HEAT-PIPE EVACUATED TUBULAR COLLECTORS

    DEFF Research Database (Denmark)

    Fan, Jianhua; Dragsted, Janne; Furbo, Simon

    2007-01-01

    Differently designed heat-pipe evacuated tubular collectors have been investigated theoretically and experimentally. The theoretical work has included development of two TRNSYS [1] simulation models for heat-pipe evacuated tubular collectors utilizing solar radiation from all directions. One model...

  8. Thermal analysis of a solar collector consisting of V cavities for water heating; Analise termica de um coletor solar composto de cavidades V para aquecimento de agua

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Michel Fabio de Souza

    2009-03-15

    The solar water heating is carried through, in Brazil, by means of solar heaters compound for collectors flat plate of the type plate-and-pipes, devices that operate in stationary position and they do not require tracking of the sun. A compound collector for some formed V-trough concentrators can be an alternative to the conventional solar collectors flat plate. This compound collector for V-trough is considered, each one, for side-walls which are specularly reflecting surfaces associates in V (equivalent to a triangular gutter). Next to the vertex to each V-trough concentrators an absorber tube is fixed, for flow of the fluid to be heated. Interconnection of the absorbers tubes forms a similar tubular network existing in solar collectors of the type the plate and pipe. V-trough concentrators with the absorbers tubes are made use in series in the interior a prismatic box, which have one of its faces consisting by a glass covering and directed toward incidence of the solar radiation. An analysis of thermal performance of these devices operating stationary and without tracking of the sun is researched. A mathematical model for the computational simulation of the optical and thermal performance of these concentrative devices is elaborated, whose implementation was carried through software EES (Engineering Equation Solver). The efficiency optics of V-trough concentrators with cylindrical absorbers is calculated from the adaptation of the methodology used for Fraidenraich (1994), proposal for Hollands (1971) for V-trough cavities with plain absorbers. The thermal analysis of the considered collector was based on the applied methodology the CPC for Hsieh (1981) and Leao (1989). Relative results to the thermal performance of V-trough concentrators suggest that these configurations are not competitive, technique and economically, with the conventional plain collectors. Although some geometric configurations presented next thermal efficiencies to the conventional plain

  9. Analysis of PV/T flat plate water collectors connected in series

    Energy Technology Data Exchange (ETDEWEB)

    Dubey, Swapnil; Tiwari, G.N. [Centre for Energy Studies, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016 (India)

    2009-09-15

    Photovoltaic-thermal (PV/T) technology refers to the integration of a PV and a conventional solar thermal collector in a single piece of equipment. In this paper we evaluate the performance of partially covered flat plate water collectors connected in series using theoretical modeling. PV is used to run the DC motor, which circulates the water in a forced mode. Analytical expressions for N collectors connected in series are derived by using basic energy balance equations and computer based thermal models. This paper shows the detailed analysis of thermal energy, exergy and electrical energy yield by varying the number of collectors by considering four weather conditions (a, b, c and d type) for five different cities (New Delhi, Bangalore, Mumbai, Srinagar, and Jodhpur) of India. Annual thermal and electrical energy yield is also evaluated for four different series and parallel combination of collectors for comparison purpose considering New Delhi conditions. This paper also gives the total carbon credit earned by the hybrid PV/T water heater investigated as per norms of Kyoto Protocol for New Delhi climatic conditions. Cost analysis has also been carried out. It is observed that the collectors partially covered by PV module combines the production of hot water and electricity generation and it is beneficial for the users whose primary requirement is hot water production and collectors fully covered by PV is beneficial for the users whose primary requirement is electricity generation. We have also found that if this type of system is installed only in 10% of the total residential houses in Delhi then the total carbon credit earned by PV/T water heaters in terms of thermal energy is USD $144.5 millions per annum and in terms of exergy is USD $14.3 millions per annum, respectively. (author)

  10. Lifetime of solar collectors in solar heating plants; Levetid for solfangere i solvarmecentraler

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Z.; Fan, J.; Perers, B.; Furbo, S.

    2009-10-15

    Two HT solar collectors, which have been in operation at high temperature levels in Ottrupgaard solar heating plant for 15 years and in Marstal solar heating plant for 13 years, were in the spring of 2009 tested with regard to efficiency. The collectors were also inspected with the aim to evaluate the life time of the collectors. An old version of the HT solar collector, which has been in operation in a Swedish test facility since 1982, was tested with regard to the thermal performance. The measurements showed that the efficiencies of the solar collectors from the two Danish solar heating plants have been decreased since the installation. The reductions of the yearly thermal performance of the solar collectors are at a temperature level of 40 centigrade Celsius, 1% and 4%, respectively, for the Marstal collector and the Ottrupgaard collector. At a temperature level of 60 centigrade Celsius the reduction of the yearly thermal performance is 10% and 11%, respectively, for the Marstal collector and the Ottrupgaard collector. At a temperature level of 80 centigrade Celsius the reduction is 27% and 23%, respectively, for the Marstal collector and the Ottrupgaard collector. Based on the inspection, it is estimated that the reason for the reduction of thermal performance is the condition of the Teflon foil and the installation of the Teflon foil. The Teflon foil is wrinkled and folded and expanded in such a way that the distance between the absorber and the Teflon foil is far too small. Further, cracks in the Teflon foil have been observed. The thermal performance of the Swedish solar collector in the test facility is after 26 years of operation reduced compared to the thermal performance of the collector when it was first installed. For this collector the reduction in thermal performance is only 2-5%. The collectors from Ottrupgaard solar heating plant and from Marstal solar heating plant were in a very good condition with exception of the above mentioned problems with

  11. Tårs 10000 m2 CSP + Flat Plate Solar Collector Plant - Cost-Performance Optimization of the Design

    DEFF Research Database (Denmark)

    Perers, Bengt; Furbo, Simon; Tian, Zhiyong

    2016-01-01

    , was established. The optimization showed that there was a synergy in combining CSP and FP collectors. Even though the present cost per m² of the CSP collectors is high, the total energy cost is minimized by installing a combination of collectors in such solar heating plant. It was also found that the CSP...... collectors could raise flexibility in the control strategy of the plant. The TRNSYS-Genopt model is based on individually validated component models and collector parameters from experiments. Optimization of the cost performance of the plant has been conducted in this paper. The simulation model remains...... to be validated with annual measured data from the plant....

  12. The program for calculation of heat productivity of solar converters with flat collectors

    Energy Technology Data Exchange (ETDEWEB)

    Kazarian, E.; Vrtanessyan, K.; Kazarian, G. [State Engineering University of Armenia, Yerevan (Armenia)

    1997-12-31

    The program for calculation of heat productivity of Solar Converters with flat collectors allows to calculate the parameters of heliosystem taking into account the input data and monthly meteorological data of regions. For solar heat study and predesigning process it is expedient to use a program for flat collectors productivity calculation. That program allows to calculate the collector`s parameters and characteristics proceeding from meteorological input data. Depending on the season of the year that program takes into account the whole absorbed solar energy and determines the coefficient for additional energy for the provision of necessary temperature

  13. Solar-collector studies for solar-heating and -cooling applications. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Liers, H. S.; Yenamandra, N.; Brittle, P. N.; Raymond, M.; Edelman, D. G.

    1979-01-01

    Mirror and lens solar concentrator collectors suitable for space heating, cooling, and hot water applications were surveyed. The scope of the survey includes identification, analysis and comparison for all concentrating collector types for which prototypes and/or market models are or have been built for less than 10X concentration. The survey includes greater than 10X concentration ratios for manufacturers marketing such collectors for space heating and/or cooling applications. Collectors in the conceptual stage are noted and their attributes and disadvantages identified.

  14. Evaluation of high performance evacuated tubular collectors in a residential heating and cooling system: Colorado State University Solar House I. Report for October 1, 1976--September 30, 1977

    Energy Technology Data Exchange (ETDEWEB)

    Duff, W.S.; Conway, T.M.; Loef, G.O.G.; Meredith, D.B.; Pratt, R.B.

    1978-03-01

    CSU Solar House I is configured with a prototype Corning evacuated tubular collector and a new Arkla lithium bromide water chiller designed for solar operation. Data have been collected for this configuration since January 1977. Prior to that time and since mid-1974, Solar House I has operated with a flat-plate collector and a previous Arkla LiBr air conditioner modified to operate in the lower solar temperature ranges. Project objectives were to develop an operating and control system for the new configuration and to compare the performance of the new residential solar heating, cooling, and hot water system with performance of the previous system. Many problems were encountered in the evolution of the operating and control systems due to the different operating characteristics of evacuated tubular collectors, such as their rapid thermal response and the possibility of much higher temperatures as compared to a flat-plate collector.

  15. Modeling Heat Flow In a Calorimeter Equipped With a Textured Solar Collector

    Science.gov (United States)

    Jaworske, Donald A.; Allen, Bradley J.

    2001-01-01

    Heat engines are being considered for generating electric power for minisatellite applications, particularly for those missions in high radiation threat orbits. To achieve this objective, solar energy must be collected and transported to the hot side of the heat engine. A solar collector is needed having the combined properties of high solar absorptance, low infrared emittance, and high thermal conductivity. To test candidate solar collector concepts, a simple calorimeter was designed, manufactured, and installed in a bench top vacuum chamber to measure heat flow. In addition, a finite element analysis model of the collector/calorimeter combination was made to model this heat flow. The model was tuned based on observations from the as-manufactured collector/calorimeter combination. In addition, the model was exercised to examine other collector concepts, properties, and scale up issues.

  16. Solar combisystems. A comparison between vacuum tube- and flat plate collectors using measurements and simulations; Solvaermda kombisystem. En jaemfoerelse mellan vakuumroer och plan solfaangare genom maetning och simulering

    Energy Technology Data Exchange (ETDEWEB)

    Kovacs, Peter; Pettersson, Ulrik

    2002-10-01

    Two solar combisystems were mounted side by side in an outdoor test facility and continuously operated during one year. The whole year, all relevant temperatures, flow rates and environment variables were thoroughly measured. The systems were identical apart from the collectors which were a 9 m{sup 2} vacuum tube and a 12.2 m{sup 2} selective flat plate collector. A simulated space heating and tap water load of approx. 25 MWh/a was applied to each system and auxiliary heat was charged to the stores from emulated pellet boilers. Additionally, the two collectors and the store was tested separately and the systems simulated according to the CTSS principle described in ENV 12977. The aim of the project was to determine solar fractions in a solar combisystem from real measurements and to compare the two different collector types from different points of view. On the basis of the validated simulation model, the results from the long term measurements could be generalized and eight different loads were simulated. The results showed that the vacuum tubes performed 45-60% better than the flat plate per m{sup 2} depending on the load applied. The solar fractions (assuming no losses from the boiler) varied from 11% for the measured systems to approx. 30 % in a house with 25 % of the original space heating load. During the heating season, the vacuum tubes occasionally performed much worse than the flat plate due to the fact that snow and frost melted away much quicker from the flat plate. For the use of vacuum tubes in snowy regions, vertical mounting should therefore be strongly recommended.

  17. Indoor thermal performance evaluation of Daystar solar collector

    Science.gov (United States)

    Shih, K., Sr.

    1977-01-01

    The test procedures used and results obtained from a test program to obtain thermal performance data on a Daystar Model 21B, S/N 02210, Unit 2, liquid solar collector under simulated conditions are described. The test article is a flat plate solar collector using liquid as a heat transfer medium. The absorber plate is copper and coated with black paint. Between the tempered low iron glass and absorber plate is a polycarbonate trap used to suppress convective heat loss. The collector incorporates a convector heat dump panel to limit temperature excursions during stagnation. The following tests were conducted: (1) collector thermal efficiency; (2) collector time constant; (3) collector incident angle modifier; (4) collector heat loss coefficient; and (5) collector stagnation.

  18. Flat-plate solar-collector performance evaluation with a solar simulator as a basis for collector selection and performance prediction

    Science.gov (United States)

    Simon, F. F.

    1975-01-01

    This paper reports the measured thermal efficiency and evaluation of 23 collectors which differ according to absorber material (copper, aluminum, steel), absorber coating (nonselective black paint, selective copper oxide, selective black nickel, selective black chrome), type of glazing material (glass, Tedlar, Lexan, anti-reflection glass), the use of honeycomb material and the use of vacuum to prevent thermal convection losses. The collectors are given performance rankings based on noon-hour solar conditions and all-day solar conditions. The determination with the simulator of an all-day collector performance is made possible by tests at different incident angles. The solar performance rankings are made based on whether the collector is to be used for pool heating, hot water, absorption air conditioning, heating, or for a solar Rankine machine.

  19. Numerical analysis of the EHD driven flow with heat transfer in a smooth channel using multiple collectors

    Science.gov (United States)

    Taghavi Fadaki, S. S.; Amanifard, N.; Deylami, H. M.; Dolati, F.

    2017-02-01

    In the present study, a new design of collecting electrodes is studied for performing a higher performance in EHD phenomena in a smooth channel. The effect of the electric field on the heat transfer enhancement and swirling flow patterns for a new design of multiple collectors in a smooth channel is numerically investigated with 2-D approach. In this regard, the corona device configuration comprises a single fixed emitting wire situated at the centerline of the channel and different grounded electrode arrangements which are in two types of wire and plate. The results indicate that the multi-collector arrangements cause significant changes in the flow pattern, heat transfer coefficient and friction factor. Furthermore, it is found that the thermal enhancement factor has remarkable growth, and EHD efficiency for two types of wire and plate collectors is notable. Besides, as an outstanding result, the electrohydrodynamic phenomenon has a negative effect on the heat transfer enhancement depending upon the values of Reynolds number and applied electric potential.

  20. The Experimental Study of Plastic Plate Solar Collector%塑料太阳能平板集热器试验研究

    Institute of Scientific and Technical Information of China (English)

    李久锋; 陈观生; 张国庆

    2015-01-01

    According to the undemanding heating rate of heat-storage solar water heater, a new type of plastic plate solar collector was designed.Under the condition of intermittent forced circulation, test on the performance of this collector was carried out and instantaneous efficiency curves were obtained.As a result, the average daily collector efficiency is 51%~55% and the temperature of tank is 45.8~50.2 ℃, which serve as a reference for the application of plastic plate solar collector.%针对蓄热型太阳能热水器对升温速率要求不高的特点,提出并研制了一种新型塑料太阳能平板集热器.在间歇性强制循环条件下,对该集热器进行性能测试,获得了瞬时效率曲线.在试验条件下,该集热器的日平均效率为51%~55%,水箱温度为45.8~50.2℃,可以为塑料平板集热器的实际应用提供依据.

  1. MATHEMATICAL MODELLING AND PERFORMANCE ANALYSIS OF DIFFERENT SOLAR AIR COLLECTORS

    Directory of Open Access Journals (Sweden)

    M. A. Karim

    2015-11-01

    Full Text Available The purpose of using solar air collectors is to raise the atmospheric air temperature to a temperature which can be used for various low and medium temperature applications. Collector, absorber and airflow arrangement are the most important components in the solar air collector. The performance of the collector depends on its heat loss and the absorber area that is in contact with the airflow. This study involves the theoretical simulation of the effect of mass flow rate on the performance, for flat plate and v-groove collectors that are in single and double pass configurations. Results show that the v-groove double pass air collector has the highest efficiency value of 56% at . The performance is greater than flat plate double pass collector, which has an efficiency of 54% under the same operating conditions. KEYWORDS: solar air collector; flat plate collector (fpc; v-groove collector; efficiency; single pass; double pass

  2. Design optimization of sinusoidal glass honeycomb for flat plate solar collectors

    Science.gov (United States)

    Mcmurrin, J. C.; Buchberg, H.

    1980-01-01

    The design of honeycomb made of sinusoidally corrugated glass strips was optimized for use in water-cooled, single-glazed flat plate solar collectors with non-selective black absorbers. Cell diameter (d), cell height (L), and pitch/diameter ratio (P/d) maximizing solar collector performance and cost effectiveness for given cell wall thickness (t sub w) and optical properties of glass were determined from radiative and convective honeycomb characteristics and collector performance all calculated with experimentally validated algorithms. Relative lifetime values were estimated from present materials costs and postulated production methods for corrugated glass honeycomb cover assemblies. A honeycomb with P/d = 1.05, d = 17.4 mm, L = 146 mm and t sub w = 0.15 mm would provide near-optimal performance over the range delta T sub C greater than or equal to 0 C and less than or equal to 80 C and be superior in performance and cost effectiveness to a non-honeycomb collector with a 0.92/0.12 selective black absorber.

  3. Standard performance tests of collectors of solar thermal energy: A selectively coated, flat-plate copper collector with one transparent cover and a tube-to-tube spacing of 3-7/8 inches

    Science.gov (United States)

    1976-01-01

    Basic test results are given of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes, and coolant flow rates. Collector efficiency is correlated in terms of inlet temperature and flux level.

  4. Standardized performance tests of collectors of solar thermal energy: A selectively coated, flat-plate copper collector with one transparent cover and a tube-to-tube spacing of 5 5/8 inches

    Science.gov (United States)

    1976-01-01

    This preliminary data report gives basic test results of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and coolant flow rates. Collector efficiency is correlated in terms of inlet temperature and flux level.

  5. Energy and exergy efficiency of heat pipe evacuated tube solar collectors

    Directory of Open Access Journals (Sweden)

    Jafarkazemi Farzad

    2016-01-01

    Full Text Available In this paper, a heat pipe evacuated tube solar collector has been investigated both theoretically and experimentally. A detailed theoretical method for energy and exergy analysis of the collector is provided. The method is also evaluated by experiments. The results showed a good agreement between the experiment and theory. Using the theoretical model, the effect of different parameters on the collector’s energy and exergy efficiency has been investigated. It is concluded that inlet water temperature, inlet water mass flow rate, the transmittance of tubes and absorptance of the absorber surface have a direct effect on the energy and exergy efficiency of the heat pipe evacuated tube solar collector. Increasing water inlet temperature in heat pipe evacuated solar collectors leads to a decrease in heat transfer rate between the heat pipe’s condenser and water.

  6. The Effect of the Angle of Inclination on the Efficiency in a Medium-Temperature Flat Plate Solar Collector

    Directory of Open Access Journals (Sweden)

    Orlando Montoya-Marquez

    2017-01-01

    Full Text Available In this experimental work, the effects of the inclination angle β and the (Ti − Ta/G on the efficiency and the UL-value were investigated on a medium-temperature flat plate solar collector. The experiments were based on steady-state energy balance, by heat flow calorimetry at indoor conditions and considering the standard American National Standard Institute/American Society of Heating Refrigerating and Air Conditioning Engineers (ANSI/ASHRAE 93-2010. The solar radiation was emulated by the Joule effect using a proportional integral derivative (PID control considering two conditions of the absorber temperature, Case 1: (To − Ti > 0, and Case 2: (To − Ti = 0. The inclination angles were 0°–90° and the (Ti − Ta/G were 0.044–0.083 m2·°C/W and 0.124–0.235 for Case 1 and Case 2, respectively. The variations of β and (Ti − Ta/G cause efficiency changes up to 0.37–0.45 (21.6% and 0.31–0.45 (45.0%, respectively, for Case 1. Also, the UL(β reached changes up to 10.1–12.0 W/m2·°C (19.2% and 8.4–12.0 W/m2·°C (41.7%, respectively, for Case 1. The most significant changes of UL(β/UL(90° vs. β were 8.0% at the horizontal position for Case 1, while for Case 2, the maximum change was 1.8% only. Therefore, the changes of the inclination angle cause significant variations of the convective flow patterns within the collector, which leads to considerable variation of the collector efficiency and its UL value.

  7. Heat pump applications and water heating by means of solar collectors. Waermepumpenanwendungen und Wasserwaermung mit Sonnenkollektoren

    Energy Technology Data Exchange (ETDEWEB)

    Szokody, G.

    1990-01-15

    About 25 to 30% of all newly constructed single-family houses in Switzerland are equipped with heat pump systems. This increasing attractivity is partly due to new techniques, e.g. microprocessor control, as well as to higher component efficiencies, a more efficient heat exchange technology, and to the compactness of systems. Active solar energy conversion, i.e. by means of solar collectors, is another technique which is predominantly applied for water heating in single-family buildings. Public investments in this field are scarce. (BWI).

  8. Multi-objective genetic algorithm for the optimization of a flat-plate solar thermal collector.

    Science.gov (United States)

    Mayer, Alexandre; Gaouyat, Lucie; Nicolay, Delphine; Carletti, Timoteo; Deparis, Olivier

    2014-10-20

    We present a multi-objective genetic algorithm we developed for the optimization of a flat-plate solar thermal collector. This collector consists of a waffle-shaped Al substrate with NiCrOx cermet and SnO(2) anti-reflection conformal coatings. Optimal geometrical parameters are determined in order to (i) maximize the solar absorptance α and (ii) minimize the thermal emittance ε. The multi-objective genetic algorithm eventually provides a whole set of Pareto-optimal solutions for the optimization of α and ε, which turn out to be competitive with record values found in the literature. In particular, a solution that enables α = 97.8% and ε = 4.8% was found.

  9. Conclusions and recommendations for the testing of flat-plate solar collector thermal performance and durability

    Science.gov (United States)

    Waksman, D.; Thomas, W. C.

    1984-12-01

    The results of studies, by the National Bureau of Standards, of the reliability and durability of eight different types of flat plate solar collectors representative of equipment available in 1977 are reported. The installations were made in four sites believed to typify various U.S. climates. The stability of the thermal performance and material properties was tracked, and measured again after moving the units inside for exposure to artificial sunlight. The stagnation measurement techniques employed to evaluate the collectors were judged adequate, provided the tests are made on-site and out of doors. It is noted that the instrumentation used to gather sufficient data for valid analyses may experience performance decrements due to the necessarily long monitoring intervals, i.e., several years.

  10. Testing of PCM Heat Storage Modules with Solar Collectors as Heat Source

    DEFF Research Database (Denmark)

    Englmair, Gerald; Dannemand, Mark; Johansen, Jakob Berg;

    2016-01-01

    . In long periods with high level of irradiance several modules were charged in parallel due to the limited heat exchange capacity of the integrated heat exchanger of the modules. After the modules were heated to more than 80° C they were set to passively cool down. Modules reached 30 °C in a period......A latent heat storage based on the phase change material Sodium Acetate Trihydrate (SAT) has been tested as part of a demonstration system. The full heat storage consisted of 4 individual modules each containing about 200 kg of sodium acetate trihydrate with different additives. The aim...... was to actively utilize the ability of the material to supercool to obtain long storage periods. The modules were charged with solar heat supplied by 22.4 m2 evacuated tubular collectors. The investigation showed that it was possible to fully charge one module within a period of 270 minutes with clear skies...

  11. An Experimental Study on Evacuated Tube Solar Collector using Therminol D-12 as Heat Transfer Fluid Coupled with Parabolic Trough

    Directory of Open Access Journals (Sweden)

    P.Selvakumar

    2014-03-01

    Full Text Available An evacuated tube solar collector using therminol D-12 as heat transfer fluid coupled with parabolic trough is studied in this paper. An experimental set-up was constructed to study the performance of evacuated tube collector with therminol D-12 as heat transfer fluid. The parabolic trough is coupled with evacuated tube collector for better performance. In the traditional solar collectors water is used as heat transfer fluid. The problems in using water as heat transfer fluid are addressed in detail in this paper. The temperature characteristics of heat transfer fluid and water in the storage tank and the heating efficiency are determined under various conditions. The efficiency of therminol based evacuated tube collector coupled with parabolic trough is 40% more than that of water based evacuated tube collector coupled with parabolic trough. This study projects the potential of therminol based evacuated tube solar collector coupled with parabolic trough in the instant hot water generation.

  12. Examination of processes of heat exchange in collector thermosyphons of switching boards high degree of integration.

    Directory of Open Access Journals (Sweden)

    Nikolaenko Yu. Е.

    2007-12-01

    Full Text Available The article presents the research of heat exchange and hydrodynamics of the heat transfer medium in the channels of the collector thermosyphon built into the heat load switching board. The most rational geometry of evaporation channels is chosen. Experimentally obtained dependences of the temperature of switching boards surface on the power of supplied heat flow are given. It is shown that the insertion of collector thermosiphons based on slot channels into the switching board can halve the temperature of the heat-supply zone.

  13. An Experimental and Analytical Study of a Radiative Cooling System with Unglazed Flat Plate Collectors

    DEFF Research Database (Denmark)

    Hosseinzadeh, Elham; Taherian, Hessam

    2012-01-01

    On an average about 40% of world energy is used in residential buildings and the largest energy consumption is allocated to the cooling and air-conditioning systems. So every attempt to economize energy consumption is very valuable. In this research a nocturnal radiative cooling system with flat...... as a guideline to derive the governing equations of a night sky radiator. Then, a cooling loop, including a storage tank, pump, connecting pipes, and a radiator has been studied experimentally. The water is circulated through the unglazed flat-plate radiator having 4 m2 of collector area at night to be cooled...

  14. A Flat Solar Collector Built from Galvanized Steel Plate, Working by Thermosyphonic Flow, Optimized for Mexican Conditions

    Directory of Open Access Journals (Sweden)

    Á. Marroquín de Jesús

    2009-07-01

    Full Text Available Design, construction, and testing of the thermal performance of a flat solar collector for domestic water heating are described. The absorbing plate is built from readily available materials: two sheets of galvanized steel, one of the channelled type, the other one flat, which are joined by electric welding. The absorber is connected to a 198–L thermotank, insulated with polyurethane foam. In terms of receiving surface, the prototype tested here has an area of 1.35 m2, about 20% smaller than comparable copper–tube–based collectors offered in the market. Temperature measurements conducted over a 30–day period gave values which were a few degrees lower than the theoretically calculated water temperatures. Momentary thermal efficiency values between 35% and 77% were observed. The water temperature achieved in the tank at the end of the day aver ages 65°C in winter weather conditions in the central Mexican highland. This design of solar water heater is well suited to Mexican conditions, as it makes use of the high local intensity of the solar radiation, and as the channel shape of the ducts minimizes bursting during the rare occurrences of freezing temperatures in the region; it also has the advantage of being manufacturable at low cost from simple materials.

  15. The Optimum Plate to Plate Spacing for Maximum Heat Transfer Rate from a Flat Plate Type Heat Exchanger

    Science.gov (United States)

    Ambarita, Himsar; Kishinami, Koki; Daimaruya, Mashashi; Tokura, Ikuo; Kawai, Hideki; Suzuki, Jun; Kobiyama, Mashayosi; Ginting, Armansyah

    The present paper is a study on the optimum plate to plate spacing for maximum heat transfer rate from a flat plate type heat exchanger. The heat exchanger consists of a number of parallel flat plates. The working fluids are flowed at the same operational conditions, either fixed pressure head or fixed fan power input. Parallel and counter flow directions of the working fluids were considered. While the volume of the heat exchanger is kept constant, plate number was varied. Hence, the spacing between plates as well as heat transfer rate will vary and there exists a maximum heat transfer rate. The objective of this paper is to seek the optimum plate to plate spacing for maximum heat transfer rate. In order to solve the problem, analytical and numerical solutions have been carried out. In the analytical solution, the correlations of the optimum plate to plate spacing as a function of the non-dimensional parameters were developed. Furthermore, the numerical simulation is carried out to evaluate the correlations. The results show that the optimum plate to plate spacing for a counter flow heat exchanger is smaller than parallel flow ones. On the other hand, the maximum heat transfer rate for a counter flow heat exchanger is bigger than parallel flow ones.

  16. Hybrid utilization of solar energy. Part 2. Performance analyses of heating system with air hybrid collector; Taiyo energy no hybrid riyo ni kansuru kenkyu. 2. Kuki shunetsu hybrid collector wo mochiita danbo system no seino hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Yoshinaga, M.; Okumiya, M. [Nagoya University, Nagoya (Japan)

    1996-10-27

    For the effective utilization of solar energy at houses, a heating system using an air hybrid collector (capable of simultaneously performing heat collection and photovoltaic power generation). As the specimen house, a wooden house of a total floor area of 120m{sup 2} was simulated. Collected air is fanned into a crushed stone heat accumulator (capable of storing one day`s collection) or into a living room. The output of solar cell arrays is put into a heat pump (capable of handling a maximum hourly load of 36,327kJ/h) via an inverter so as to drive the fan (corresponding to average insolation on the heat collecting plate of 10.7MJ/hm{sup 2} and heat collecting efficiency of 40%), and shortage in power if any is supplied from the system interconnection. A hybrid collector, as compared with the conventional air collector, is lower in thermal efficiency but the merit that it exhibits with respect to power generation is far greater than what is needed to counterbalance the demerit. When the hybrid system is in heating operation, there is an ideal heat cycle of collection, accumulation, and radiation when the load is light, but the balance between accumulation and radiation is disturbed when the load is heavy. 4 refs., 8 figs., 3 tabs.

  17. Solar energy dryer kinetics using flat-plate finned collector and forced convection for potato drying

    Science.gov (United States)

    Batubara, Fatimah; Misran, Erni; Dina, Sari Farah; Heppy

    2017-06-01

    Research on potato drying using the indirect solar dryer with flat-plate finned collector and forced convection has been done. The research was conducted at the outdoor field of Laboratory of Institute for Research and Standardization of Industry on June 14th-23rd, 2016 from 9:00 am to 4:00 pm. This research aims to obtain the drying kinetics model of potato (Solanumtuberosum L.) using an indirect solar dryer's (ISD) with flat plate-finned collector and forced convection. The result will be compared to the open sun drying (OSD) method. Weather conditions during the drying process took place as follows; surrounding air temperature was in the range 27 to 34.7 °C, relative humidity (RH) 29.5 to 61.0% and the intensity of solar radiation 105.6 to 863.1 Watt/m2. The dried potato thicknesses were 1.0 cm, 1.5 cm and 2.0 cm, with the average initial water content of 76.46%. The average temperature in the collector chamber ranged from 42.2 to 57.4 °C and the drying chamber was at 46.2 °C. The best drying result was obtained from a sample size of 1 cm thickness using the IDS method with an average drying rate of 0.018 kg H2O per kg dry-weight.hour and the water content was constant at 5.02% in 21 hours of drying time. The most suitable kinetics model is Page model, equation MR = exp (-0.049 t1,336) for 1.0 cm thickness, exp (-0.066 t1,222) for 1.5 cm thickness and exp (-0.049 t1,221) for 2.0 cm thickness. The quality of potato drying using ISD method is better than using OSD which can be seen from the color produced.

  18. The effect of contact spacing on the efficiency of flat plate solar collector plates

    Science.gov (United States)

    Schneider, G. E.; Crha, S.

    1984-01-01

    Rather than use a continuous weld or solder for thermal contact in the attachment of an extended surface to an energy removal tube, attention is given to the use of discontinuous attachment through the uniform distribution of finite regions of contact. This scheme is applied to a solar energy collection system in which it was thought capable of yielding fabrication and reliability improvements. A nondimensional formulation and numerical solution of FEM modeling yields the sensitivity of collector thermal performance to weld-solder joint dimensions. The discontinuous weld is found to significantly degrade system performance in proportion to the fin surface Biot modulus, with the controlling parameter (with respect to weld dimensions) being the perimeter length at the weld location of contact.

  19. Development and investigation of solar collectors for conversion of solar radiation into heat and/or electricity

    Directory of Open Access Journals (Sweden)

    Stefanović Velimir P.

    2006-01-01

    Full Text Available This article describes work on two projects of the National Energy Efficiency Program NEEP 709300036 and NPEE 271003 titled "The model of solar collector for middle temperature conversion of solar radiation in heat" and "Development and investigation on hybrid solar collector for heat and electricity generation", respectively. This first project deals with solar collector that transfers solar radiation in heat in area of middle temperature conversion (at temperatures above 100 ºC. During entire year it can realize significant saving of electric energy used for preparation of warm water and in central and district heating. During work on the second project, two hybrid solar collectors, their installation, mathematical model, software, and experimental set-up were designed and realized. The first collector had the photovoltaic panel located above the absorber and the second collector had the panel located on the absorber. For both collectors, the results show that efficiency of fossil fuel replacement is 85%. .

  20. An effective simulation model to predict and optimize the performance of single and double glaze flat-plate solar collector designs

    OpenAIRE

    Kaplanis, S.; Kaplani, E.

    2012-01-01

    This paper outlines and formulates a compact and effective simulation model, which predicts the performance of single and double glaze flat-plate collector. The model uses an elaborated iterative simulation algorithm and provides the collector top losses, the glass covers temperatures, the collector absorber temperature, the collector fluid outlet temperature, the system efficiency, and the thermal gain for any operational and environmental conditions. It is a numerical approach based on simu...

  1. Linear concentrating Fresnel collector for process heat applications; Linear konzentrierender Fresnel-Kollektor fuer Prozesswaermeanwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Haeberle, A.; Berger, M.; Luginsland, F.; Zahler, C. [PSE GmbH, Solar Info Center, Freiburg (Germany); Rommel, M.; Baitsch, M.; Henning, H.M. [Fraunhofer ISE, Freiburg (Germany)

    2006-07-01

    A prototype of a small Fresnel process heat collector was built in Freiburg in late 2005 for thermal performance measurements. The collector is designed for applications bigger than 50 kW{sub th} and a driving temperature of around 200 C. The first application will be a solar cooling system with a NH{sub 3}/H{sub 2}O absorption chiller, which will be installed in June 2006. (orig.)

  2. Ion plating with an induction heating source

    Science.gov (United States)

    Spalvins, T.; Brainard, W. A.

    1976-01-01

    Induction heating is introduced as an evaporation heat source in ion plating. A bare induction coil without shielding can be directly used in the glow discharge region with no arcing. The only requirement is to utilize an rf inductive generator with low operating frequency of 75 kHz. Mechanical simplicity of the ion plating apparatus and ease of operation is a great asset for industrial applications; practically any metal such as nickel, iron, and the high temperature refractories can be evaporated and ion plated.

  3. A Comparison of the Thermodynamic Efficiency of Vacuum Tube and Flat Plate Solar Collector Systems

    Directory of Open Access Journals (Sweden)

    Juozas Bielskus

    2013-12-01

    Full Text Available The article presents simulation based exergy analysis used for comparing solar thermal systems applied for preparing domestic hot water. The simulation of flat and vacuum tube solar collector systems was performed in TRNSYS simulation environment. A period of one year under Lithuanian climate conditions was chosen. Simulation was performed on 6 min time step resolution by calculating energy and exergy flows and creating balance calculation. Assessment results at system and element levels have been presented as monthly variation in efficiency. The conducted analysis has revealed that the systems designed to cover equal heat energy demand operates in different exergetic efficiencies.Article in Lithuanian

  4. A Semi-Instantaneous Heat Exchanger for Mobile Solar Collectors Test System

    Directory of Open Access Journals (Sweden)

    Haifeng Cao

    2013-07-01

    Full Text Available A semi-instantaneous heat exchanger which can solve low efficiency and space shortage of mobil test system for thermal performance of solar collectors is proposed in this paper, In this paper, the structure parameters of heat exchanger and the power of heat resistance are designed based on the method of mean temperature difference. The experiment results show the performance of test system has been optimized. The efficiency of collectors test can be increased 50% and the total weight of the primary heater and working medium is reduced to 13.8%.The load of the test vehicle and occupancy volume have been decreased.

  5. Review of state-of-the-art of solar collector corrosion processes. Task 1 of solar collector studies for solar heating and cooling applications. Final technical progress report

    Energy Technology Data Exchange (ETDEWEB)

    Clifford, J E; Diegle, R B

    1980-04-11

    The state-of-the-art of solar collector corrosion processes is reviewed, and Task 1 of a current research program on use of aqueous heat transfer fluids for solar heating and cooling is summarized. The review of available published literature has indicated that lack of quantitative information exists relative to collector corrosion at the present time, particularly for the higher temperature applications of solar heating and cooling compared to domestic water heating. Solar collector systems are reviewed from the corrosion/service life viewpoint, with emphasis on various applications, collector design, heat transfer fluids, and freeze protection methods. Available information (mostly qualitative) on collector corrosion technology is reviewed to indicate potential corrosion problem areas and corrosion prevention practices. Sources of limited quantitative data that are reviewed are current solar applications, research programs on collector corrosion, and pertinent experience in related applications of automotive cooling and non-solar heating and cooling. A data bank was developed to catalog corrosion information. Appendix A of this report is a bibliography of the data bank, with abstracts reproduced from presently available literature accessions (about 220). This report is presented as a descriptive summary of information that is contained in the data bank.

  6. Monitoring of a flat plate solar thermal field supplying process heat

    Directory of Open Access Journals (Sweden)

    Cozzini Marco

    2016-01-01

    Full Text Available The article reports the performance data of a flat plate collector field installed in Austria and supplying process heat to a meat factory, up to a temperature of about 95 °C. The presented data span an entire year, thereby including seasonal effects and allowing for a full characterization of the system performances. Sensor uncertainty is also discussed in detail. Finally, a bin method analysis of the field efficiency is provided. To this purpose, different operating conditions are concisely represented by the so-called reduced temperature, typically used in solar collector applications.

  7. A Review on Heat Transfer Improvent of Plate Heat Exchanger

    Directory of Open Access Journals (Sweden)

    Abhishek Nandan

    2015-03-01

    Full Text Available Plate heat exchanger has found a wide range of application in various industries like food industries, chemical industries, power plants etc. It reduces the wastage of energy and improves the overall efficiency of the system. Hence, it must be designed to obtain the maximum heat transfer possible. This paper is presented in order to study the various theories and results given over the improvement of heat transfer performance in a plate heat exchanger. However, there is still a lack in data and generalized equations for the calculation of different parameters in the heat exchanger. It requires more attention to find out various possible correlations and generalized solutions for the performance improvement of plate heat exchanger.

  8. Standard Test Method for Water Penetration of Flat Plate Solar Collectors by Uniform Static Air Pressure Difference

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1986-01-01

    1.1 This test method covers the determination of the resistance of flat plate solar collectors to water penetration when water is applied to their outer surfaces with a static air pressure at the outer surface higher than the pressure at the interior of the collector. 1.2 This test method is applicable to any flat plate solar collector. 1.3 The proper use of this test method requires a knowledge of the principles of pressure and deflection measurement. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary information is contained in Section 6.

  9. Simulating Single-Effect Absorption Cooling Lithium Bromide A Solar System With Flat Plate Collector And Contribute To An Office Building

    OpenAIRE

    MIRI, Mohadaseh

    2015-01-01

    Use solar energy to provide hot water consumption, space heating and cooling in recent decades is considered. In this article a model varies with time, a solar adsorption cooling system consists of a single effect lithium bromide absorption system, a flat plate collector and a storage tank or linear or parabolic simulated separately. The system for cooling an office building for hours of operation from 7 am to 18 pm is considered.About 7 kW peak cooling load occurs in July. Results obtained s...

  10. Air bubble-induced detachment of polystyrene particles with different sizes from collector surfaces in a parallel plate flow chamber

    NARCIS (Netherlands)

    Gomez-Suarez, C; van der Mei, HC; Busscher, HJ

    2001-01-01

    Particle size was found to be an important factor in air bubble-induced detachment of colloidal particles from collector surfaces in a parallel plate flow chamber and generally polystyrene particles with a diameter of 806 nm detached less than particles with a diameter of 1400 nm. Particle

  11. Evaluation of flat-plate collector efficiency under controlled conditions in a solar simulator

    Science.gov (United States)

    Johnson, S. M.; Simon, F. F.

    1976-01-01

    The measured thermal efficiencies of 35 collectors tested with a solar simulator, along with the correlation equations used to generalize the data, are presented in this report. The single correlation used is shown to apply to all the different types of collectors tested, including one with black paint and one cover, one with a selective surface coating and two covers, and an evacuated-tube collector. The test and correlation technique is also modified by using a shield so that collectors larger than the simulator test area can also be tested. This technique was verified experimentally for a shielded collector for which the collector shielded area was 31% of the solar simulator radiation area. A table lists all the collectors tested, the collector areas, and the experimental constants used to correlate the data for each collector.

  12. Temperature Uniformity of Heated Mold Plate by Oscillating Heat Pipe

    Directory of Open Access Journals (Sweden)

    Kamonpet Patrapon

    2015-01-01

    Full Text Available Uniformity of the temperature in the mold plate is of paramount important since it will affect the dimensional stability of the part produced. To provide uniform temperature to the metal plate, many factors need to be considered such as choice of heating technology, uniformity of a heat source, a type of control, etc. This paper aims to study the temperature uniformity of metal plate using closed-loop oscillating heat pipe (CLOHP as a heat transfer device. The metal plates which were P-20 with the size of 306 x 130 mm2 were used. Metal plate was gouged to a depth of 3 mm for installing the CLOHP. Distances from the heating device to the metal plate surface were 5 and 10 mm. The surface temperatures of the metal plate were controlled at 80, 90, 100, 110, 120, and 130°C. Sixteen pointa of temperature were recorded. The results were then compared to those using the heat source as the cartridge heater arranged in the similar way with the same heating capacity. Once the system entered the steady state, it was found that the temperature distribution of metal plate using the CLOHP has a deviation in the range of ± 1.00°C and ± 0.94°C at the CLOHP depth of 5 mm. and 10 mm., respectively. While those of using cartridge heater deviated in the range of ± 1.35°C and ± 1.16°C. Compare to the recommended value from the ASTM Standard that the mold surface temperature need to be in the range of ± 2.0°C, the CLOHP shows the very promising results.

  13. Investigation of methods to transfer heat from solar liquid-heating collectors to heat storage tanks. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Horel, J. D.; de Winter, F.

    1978-04-20

    A study was made of the methods available to transfer heat from the collector to the water storage tank in water heating systems. In counterflow heat exchangers used in double loop water heating systems, it was found to be more important to use a high water flowrate than a high heat transfer fluid flowrate. It was earlier thought to be best to have matched WC/sub p/ (mass flowrate-specific heat) products in the loops. It was shown in this study that the water WC/sub p/ product should be about twice as large as that of the heat transfer fluid. It was found that neither the heat exchanger type nor the size was very critical, so that very simple criteria were adequate in determining optimum heat exchanger size. It was found that there is a definite system size below which one should use a traced tank or a coil in a tank. Equations and optimization criteria were developed for traced tanks or tanks with coils. At present, there is no quantitative understanding of liquid to liquid (direct contact) heat exchangers, though they are clearly quite effective. Draindown systems are discussed, and several appendices are included on heat transfer and other characteristics of fluid and of equipment.

  14. The Air Solar Collectors: Introduction of Chicanes to Favour the Heat Transfer and Temperature in the Air Stream Dynamics

    Directory of Open Access Journals (Sweden)

    Mahfoud Omar

    2015-01-01

    Full Text Available The thermal performance of a single pass solar air heater with chicanes attached was investigated numerically using a 2D model of solar air stream dynamics collectors where the turbulence standard (k-ε model has been implemented. The chicane is formed with two parts: the first is perpendicular to the air flow and the second part is titled (α, they are mounted in successive rows, oriented perpendicular to the air flow and soldered to the back plate. The predicted results are validated by comparing with the literatures semi-empirical and experimental data and shown a reasonable agreement. Effects of relevant parameters as the (Reynolds number, chicanes upper parts tilts angles and air mass flow rates on the heat transfer coefficient and temperature development are discussed. It is apparent that the turbulence created by the chicanes resulting in greater increase in heat transfer inside the air stream dynamics.

  15. Thermal Efficiency of Power Module “Boiler with Solar Collectors as Additional Heat Source” For Combined Heat Supply System

    Directory of Open Access Journals (Sweden)

    Denysova A.E.

    2015-04-01

    Full Text Available The purpose of work is to increase the efficiency of the combined heat supply system with solar collectors as additional thermal generators. In order to optimize the parameters of combined heat supply system the mathematical modeling of thermal processes in multi module solar collectors as additional thermal generators for preheating of the water for boiler have been done. The method of calculation of multi-module solar collectors working with forced circulation for various configurations of hydraulic connection of solar collector modules as the new result of our work have been proposed. The results of numerical simulation of thermal efficiency of solar heat source for boiler of combined heat supply system with the account of design features of the circuit; regime parameters of thermal generators that allow establishing rational conditions of its functioning have been worked out. The conditions of functioning that provide required temperature of heat carrier incoming to boiler and value of flow rate at which the slippage of heat carrier is not possible for different hydraulic circuits of solar modules have been established.

  16. Study on a Flat Plate Solar Air Collector with Baffles%扰流板型太阳能平板空气集热器集热性能

    Institute of Scientific and Technical Information of China (English)

    夏佰林; 赵东亮; 代彦军; 李勇

    2011-01-01

    对一种扰流板型太阳能平板空气集热器的集热性能进行了研究,并对各种影响集热器热性能的因素进行了分析,揭示了总热损失系数、扰流板肋片效率、流道内空气流速和扰流板的间距对效率因子和热迁移因子的影响机理.获得了扰流板型太阳能平板空气集热器的集热效率理论表达式,为此类太阳能空气集热器的设计及应用提供了参考.%A flat plate solar air collector with baffles was studied. Several factors that have influence on the thermal performance of the solar collectors were analyzed. The paper investigated the relations between the efficiency factor, the heat-removal factor of the solar air collector and the total heat loss coefficient, baffles fin efficiency, air velocity inside the flow channel, the space between baffles, and the height of baffles. Also, the time constant of the collectors was studied. The theoretical formula of the collector's thermal efficiency was obtained, which can be used for design and application of such kind of collectors.

  17. Simulation model of a solar collector with a heat capacitance on TRNSYS; TRNSYS wo mochiita netsuyoryo wo motsu heibangata shunetsuki no model ka

    Energy Technology Data Exchange (ETDEWEB)

    Yoshinaga, M. [Nagoya City University, Nagoya (Japan); Okumiya, M. [Nagoya University, Nagoya (Japan)

    1997-11-25

    A flat plate type heat collector considering a heat capacitance was structured; assembled into a solar system simulation program, TRNSYS; correction was made on this model for permeation and absorption rates as a result of incident angles onto the heat collecting surface on which sunlight reaches directly; and effectiveness of the proposed model was verified from comparing the heat collection amount with that of conventional systems and measured values. The heat collection amount decreased when incident angles of insolation are taken into consideration, and the amount approached the measured value in the case of the system with a heat capacitance. Variation in temperature at the heat collector exit decreased when the heat capacitance was taken into account. With the case of having no heat capacitance, heat collecting amount greater than the actually collected amount was calculated for days with great insolation, and less amount was calculate for smaller insolation. However, the value as a whole has become close to the measured value, though slightly greater. A value still closer to the measurements was obtained when the incident angle is considered. As seen in a seven-day average, a model having no heat capacitance and not considering the incident angle had an error from the measured value of 38.6%, while a model having a heat capacitance and considering the incident angle had an error of 9.9%. 5 refs., 7 figs.

  18. Study of the collector/heat pipe cooled externally configured thermionic diode

    Science.gov (United States)

    1973-01-01

    A collector/heat pipe cooled, externally configured (heated) thermionic diode module was designed for use in a laboratory test to demonstrate the applicability of this concept as the fuel element/converter module of an in-core thermionic electric power source. During the course of the program, this module evolved from a simple experimental mock-up into an advanced unit which was more reactor prototypical. Detailed analysis of all diode components led to their engineering design, fabrication, and assembly, with the exception of the collector/heat pipe. While several designs of high power annular wicked heat pipes were fabricated and tested, each exhibited unexpected performance difficulties. It was concluded that the basic cause of these problems was the formation of crud which interfered with the liquid flow in the annular passage of the evaporator region.

  19. Metal glass vacuum tube solar collectors are approaching lower-medium temperature heat application.

    Science.gov (United States)

    Jiang, Xinian

    2010-04-26

    Solar thermal collectors are widely used worldwide mainly for hot water preparation at a low temperature (less than 80 degrees C). Applications including many industrial processes and central air conditioning with absorption chillers, instead require lower-medium temperature heat (between 90 degrees C and 150 degrees C) to be driven when using solar thermal energy. The metal absorber glass vacuum tube collectors (MGVT) are developed for this type of applications. Current state-of-art and possible future technology development of MGVT are presented.

  20. Heat Lump in Different Pavement Layer Using Ethylene Glycol as A Solar Heat Collector

    Directory of Open Access Journals (Sweden)

    Talib Siti Hidayah Abu

    2017-01-01

    Full Text Available Due to the hot weather in Malaysia, several studies being carried out regarding solar energy harvesting and use as a noble renewable energy. Therefore, researchers start developing various methods to utilize sun’s heat as a renewable source of energy. Solar energy has been always concern researchers to develop most effective, durable and cheap methods and materials to be used as solar energy collectors in road pavements. Therefore, this study was conducted to determine the maximum heat area using ethylene glycol. The study was involved the field monitoring of the six samples of asphalt slab with stainless steel pipe with ethylene glycol and empty pipe act as the controlled sample. The pipe was arranged in three different depths of 50mm, 100mm and 150mm and keeping controlled the pipe diameter and the size of slab of 20mm and 300mm x 300mm respectively. These results show that the maximum heat extraction by the ethylene glycol was at a depth 150mm which was 51.2°C. The average percentage increments of the pipe with ethylene glycol for three days for pipe depth 50mm was 71%, while for pipe at depth 100mm and 150mm were 78% and 62% respectively. The ethylene glycol effect was more noticeable compare to the pipe without ethylene glycol and can store more heat. For the strength of pipe, the highest maximum load bearing capacity that can be supported by the stainless steel pipe was at depth 50mm and the second highest was at a depth 100mm while the third highest was at depth 150mm. So, the suitable depth to install the pipe with the consideration of both cases which was maximum heat gain and the maximum load that can be supported was at depth 50mm.

  1. Comparing between predicted output temperature of flat-plate solar collector and experimental results: computational fluid dynamics and artificial neural network

    Directory of Open Access Journals (Sweden)

    F Nadi

    2017-05-01

    Full Text Available Introduction The significant of solar energy as a renewable energy source, clean and without damage to the environment, for the production of electricity and heat is of great importance. Furthermore, due to the oil crisis as well as reducing the cost of home heating by 70%, solar energy in the past two decades has been a favorite of many researchers. Solar collectors are devices for collecting solar radiant energy through which this energy is converted into heat and then heat is transferred to a fluid (usually air or water. Therefore, a key component in performance improvement of solar heating system is a solar collector optimization under different testing conditions. However, estimation of output parameters under different testing conditions is costly, time consuming and mostly impossible. As a result, smart use of neural networks as well as CFD (computational fluid dynamics to predict the properties with which desired output would have been acquired is valuable. To the best of our knowledge, there are no any studies that compare experimental results with CFD and ANN. Materials and Methods A corrugated galvanized iron sheet of 2 m length, 1 m wide and 0.5 mm in thickness was used as an absorber plate for absorbing the incident solar radiation (Fig. 1 and 2. Corrugations in absorber were caused turbulent air and improved heat transfer coefficient. Computational fluid dynamics K-ε turbulence model was used for simulation. The following assumptions are made in the analysis. (1 Air is a continuous medium and incompressible. (2 The flow is steady and possesses have turbulent flow characteristics, due to the high velocity of flow. (3 The thermal-physical properties of the absorber sheet and the absorber tube are constant with respect to the operating temperature. (4 The bottom side of the absorber tube and the absorber plate are assumed to be adiabatic. Artificial neural network In this research a one-hidden-layer feed-forward network based on the

  2. Design of convex hull plate forming by pure line heating

    Institute of Scientific and Technical Information of China (English)

    ZHANG Xue-biao; JI Zhuo-shang; LIU Yu-jun

    2004-01-01

    This paper presents a ship-hull plate forming way by pure line heating. The heating lines forming the required bending angle is determined by curvature analysis method. Heating along the calculated heating lines results in bland plate with initial transverse curvature. Then, the plate with desired convex shape can be obtained by heating in the longitudinal edge. This is the whole forming process by pure line heating. This paper presents a method of plane development for ship-hull plate with B-spline surface representation, and provides the shrinkage heating lines in the forming process. This forming way would facilitate temperature control and make plate forming automatically easy.

  3. The Potential of Heat Collection from Solar Radiation in Asphalt Solar Collectors in Malaysia

    Science.gov (United States)

    Beddu, Salmia; Talib, Siti Hidayah Abdul; Itam, Zarina

    2016-03-01

    The implementation of asphalt solar collectors as a means of an energy source is being widely studied in recent years. Asphalt pavements are exposed to daily solar radiation, and are capable of reaching up to 70°C in temperature. The potential of harvesting energy from solar pavements as an alternative energy source in replace of non-renewable energy sources prone to depletion such as fuel is promising. In Malaysia, the sun intensity is quite high and for this reason, absorbing the heat from sun radiation, and then utilizing it in many other applications such as generating electricity could definitely be impressive. Previous researches on the different methods of studying the effect of heat absorption caused by solar radiation prove to be quite old and inaffective. More recent findings, on the otherhand, prove to be more informative. This paper focuses on determining the potential of heat collection from solar radiation in asphalt solar collectors using steel piping. The asphalt solar collector model constructed for this research was prepared in the civil engineering laboratory. The hot mixed asphalt (HMA) contains 10% bitumen mixed with 90% aggregates of the total size of asphalt. Three stainless steel pipes were embedded into the interior region of the model according to the design criteria, and then put to test. Results show that harvesting energy from asphalt solar collectors proves highly potential in Malaysia due its the hot climate.

  4. Performance of solar collectors under low temperature conditions

    DEFF Research Database (Denmark)

    Bunea, Mircea; Eicher, Sara; Hildbrand, Catherine

    The performance of four solar thermal collectors (flat plate, evacuated tube, unglazed with rear insulation and unglazed without rear insulation) was experimentally measured and simulated for temperatures below ambient. The influence of several parameters (e.g. collector inlet temperature, air...... temperature, condensation) is investigated under different operating conditions (day and night). Under some conditions condensation might occur and heat gains could represent up to 55% of the total unglazed collector energy by night. Two TRNSYS collector models including condensation heat gains are also...... to be around 2%, frost heat gains were measured to be up to 40% per day, under specific conditions. Overall, results have shown that unglazed collectors are more efficient than flat plate or evacuated tube collectors at low operation temperatures or for night conditions, making them more suitable for heat pump...

  5. Desiccant cooling using unglazed transpired solar collectors

    Science.gov (United States)

    Pesaran, A. A.; Wipke, K.

    1992-05-01

    The use of unglazed solar collectors for desiccant regeneration in a solid desiccant cooling cycle was investigated because these collectors are lower in cost than conventional glazed flat-plate collectors. Using computer models, the performance of a desiccant cooling ventilation cycle integrated with either unglazed transpired collectors or conventional glazed flat-plate collectors was obtained. We found that the thermal performance of the unglazed system was lower than the thermal performance of the glazed system because the unglazed system could not take advantage of the heat of adsorption released during the dehumidification process. For a 3-ton cooling system, although the area required for the unglazed collector was 69 percent more than that required for the glazed collector, the cost of the unglazed collector array was 44 percent less than the cost of the glazed collector array. The simple payback period of the unglazed system was half of the payback period of the glazed collector when compared to an equivalent gas-fired system. Although the use of unglazed transpired collectors makes economic sense, some practical considerations may limit their use in desiccant regeneration.

  6. General solution of collector performance with axial conduction and end effects

    Science.gov (United States)

    Shouman, A. R.; Tag, I. A.

    The Phillips solution of the flat-plate solar collector is extended and utilized to examine the influence of the end losses on collector performance. The results of this study show that the influence of the end temperatures of the absorber plate is more significant than the losses due to the axial conductivity of an insulated end collector plate. It will be shown that for an insulated end collector, the loss in the heat removal factor due to axial conductivity is negligible in the region of interest for flat-plate collectors. However, the end temperatures of the collector plate have more significant influence on the same factor, showing losses in some regions and improvements in other regions. This study emphasizes the necessity of measuring the temperature of the absorber plate at both the fluid inlet and exit locations in order to determine accurately the collector performance parameters.

  7. Use of mirrors with plate collectors; Uso de espejos con colectores planos

    Energy Technology Data Exchange (ETDEWEB)

    Follari, J. A.; Odicino, L. a.; Perello, A. D.; Fasulo, A. J.

    2004-07-01

    We analyze the solar radiative contribution that a fixed flat mirror cam perform on a collector, also fixed in its position , if that mirror is put above the collector. Various angles, be they for the mirror or for the collector are investigated, in order to determine their practical usefulness as a function of the real effective contribution they provide. First the theoretical contribution is calculated using approximative formulae, then the effective contribution to a solar collector connected to a thermal reservoir mow forming a solar heater, is measured. The field of applicability of this device is analyzed considering the cost of collector and the mirror, the usefulness depending on the angle between the collector and the horizontal plain. (Author)

  8. 太阳能集热器强化传热特性研究%Research on Enhancing Heat Transfer Characteristics of Solar Energy Collector

    Institute of Scientific and Technical Information of China (English)

    刘春慧; 沈啸; 李松; 李锦生

    2015-01-01

    在自然对流的情况下,在理论分析的基础上,对太阳能集热器的典型结构进行优化。在对吸热板进行改良后,采用对比试验的方法,研究太阳能集热器的强化传热特性。分析热性能效率曲线可知:吸热板添加筛网和墨绿色涂层的集热器集热效果较优,可达到强化传热的目的。%The article is to optimize typical structure of solar energy collector on the basis of theoretical analysis and under the condition of natural convection flow. After the improvement of absorber plate, it took contrast tests to study heat transfer characteristics of solar energy collector. By analyzing thermal performance efficiency curve, we can know that the heat collecting effect of solar energy collector whose absorber plate added screen mesh and blackish green coating is optimal, it can achieve the purpose of strengthening heat transfer.

  9. Optimization of Thin-Film Transparent Plastic Honeycomb Covered Flat-Plate Solar Collectors. Phase 2.

    Science.gov (United States)

    2007-11-02

    the former preferred for high-temperature collectors since it is opaque in the longer wavelength region and hence improves the efficiency by reducing re...different temperature regions . The analyses show that collectors equipped with Lexan honeycomb are more cost ef- fective than comparable nonhoneycomb...Contract E(04-3)- 1081. " REFERENCES 1. Francia , G., "A New Collector of Solar Energy -- Theory and Experimental Verification -- Calculation of the

  10. NUMERICAL SIMULATION OF THE AIR FLOW AROUND THE ARRAYS OF SOLAR COLLECTORS

    Directory of Open Access Journals (Sweden)

    Vukman V Bakić

    2011-01-01

    Full Text Available This paper deals with the numerical simulation of air around the arrays of flat plate collectors and determination of the flow field, which should provide a basis for estimating a convective heat losses, a parameter which influences their working characteristics. Heat losses are the result of the reflection on the glass, conductive losses at the collector's absorber plate, radiation of the absorber plate and convective losses on the glass. Wind velocity in the vicinity of the absorber plate depends on its position in the arrays of collectors. Results obtained in the numerical simulation of flow around collectors were used as boundary conditions in modeling of thermal-hydraulic processes inside the solar collector. A method for coupling thermal-hydraulic processes inside the collector with heat transfer from plate to tube bundle was developed, in order to find out the distribution of the temperature of the absorber plate and the efficiency of the flat plate collectors. Analyses of flow around arrays of collectors are preformed with RNG k - ε model. Three values for free-stream velocity were analysed, i.e. 1 m/s, 5 m/s and 10 m/s, as well as two values for the angle between the ground and the collector (20° and 40°. Heat transfer coefficient was determined from the theory of boundary layer. Heat transfer inside the plate cavity was analyzed assuming constant intensity of radiation.

  11. Experimental investigations of the performance of a solar air collector with latent heat thermal storage integrated with the solar absorber

    Directory of Open Access Journals (Sweden)

    Hejcik J.

    2013-04-01

    Full Text Available The paper deals with experimental investigations of the performance of a solar air collector with latent heat thermal storage integrated with the solarabsorber. The main purpose of heat storage in solar thermal systems is to store heat when the supply of solar heat exceeds demand and release it when otherwise. A number of heat storage materials can be used for this purpose; the phase change materials among them. Short-term latent heat thermal storage integrated with the solar absorber can stabilize the air temperature at the outlet of the collector on cloudy days when solar radiation intensity incident on a solar collector fluctuates significantly. Two experimental front-and-back pass solar air collectors of the same dimensions have been built for the experimental investigations. One collector had a “conventional” solar absorber made of a metal sheet while the solar absorber of the other collector consisted of containers filled with organic phase change material. The experimental collectors were positioned side by side during the investigations to ensure the same operating conditions (incident solar radiation, outdoor temperature.

  12. Aid To Solar Collector Development

    Science.gov (United States)

    1979-01-01

    Solar heating and cooling systems employ coatings to increase efficiency. Designers want a coating which absorbs solar heat to the maximum extent possible with minimal emittance of infrared radiation, which occurs when the collector plate gets hot. The coating is important because too much coating causes energy loss by emittance, too little reduces the collector's ability to absorb heat. NASA's Lewis Research Center, which conducts solar energy research, saw a need for a simple means of testing coating samples for emittance. Such equipment is available to research laboratories, but it is complex and expensive

  13. Air-liquid solar collector for solar heating, combined heating and cooling, and hot water subsystems

    Science.gov (United States)

    1978-01-01

    A collection of quarterly reports consisting of the installation and layout design of the air collector system for commercial applications, completion of the preliminary design review, detailed design efforts, and preparation of the verification test plan are given. Performance specifications and performance testing of a prototype model of a two manifold, 144 tube air collector array is presented.

  14. Models of the heat dynamics of solar collectors for performance testing

    DEFF Research Database (Denmark)

    Bacher, Peder; Madsen, Henrik; Perers, Bengt

    2011-01-01

    accurate estimates of parameters in physical models. The applied method is described by Kristensen et al. (2004) and implemented in the software CTSM1. Examples of successful applications of the method includes modelling the of the heat dynamics of integrated photo-voltaic modules (Friling et al., 2009...... rig is described in Fan et al. (2009). The modelling technique provides uncertainty estimates such as confidence intervals for the parameters, and furthermore enables statistical validation of the results. Such tests can also facilitate procedures for selecting the best model to use, which is a very......The need for fast and accurate performance testing of solar collectors is increasing. This paper describes a new technique for performance testing which is based on non-linear continuous time models of the heat dynamics of the collector. It is shown that all important performance parameters can...

  15. A self-tractable solar collector

    Science.gov (United States)

    Abdulhadi, M.; Ghorayeb, F.

    2006-06-01

    An analytical experimental investigation into the thermal performance of a tubeless hemispherical (a spherical cap) solar collector for use in heating and cooling purposes is presented. The receiver plate surface temperature was estimated at the prevailing steady-state conditions from the energy balance equation on the absorber plate. From the experimental analytical investigation, the present collector was found to be much more efficient than a flat-plate collector. Fluid outlet temperatures over 95°C could be provided on mid clear shining sunny days. Remembering the easiness of building a complex of such a collector, it follows that plenty of residential and industrial implementations, mostly in heating and cooling refrigeration absorption cycles, could be undertaken.

  16. Coaxial extrusion conversion concept for polymeric flat plate solar collectors. Final technical report, September 30, 1978-December 31, 1979

    Energy Technology Data Exchange (ETDEWEB)

    Rhodes, R.O.; Chapman, N.J.; Chao, K.C.; Sorenson, K.F.

    1980-01-01

    This study investigated materials and processes for fundamental improvements in flat-plate solar collector cost and performance. The goal was to develop a process for direct conversion of inexpensive raw materials into a completed solar collector unit, without labor intensive assembly operations. It was thought that materials carefully matched to the process and end-use environment would substantially reduce collector costs, as compared to conventional industry practice. The project studied the feasibility of a cost-effective, glazed solar collector, with low labor input, utilizing a coaxial extrusion of compatible polymeric materials. This study evaluated all considered materials for the desired application. In addition, there was a trial extrusion of the leading candidate glazing and absorber materials, which resulted in successfully performing a coaxial extrusion of one cell. At the time the study was conducted, there were no materials available that met the necessary requirements for the specified utilization. It was recommended that, if potentially compatible materials become available, further investigation into the suitability of those materials be researched. Then, if a suitable material was found, proceeding into Phase II would be recommended.

  17. SIMULATION OF SOLAR LITHIUM BROMIDE–WATER ABSORPTION COOLING SYSTEM WITH DOUBLE GLAZED FLAT PLATE COLLECTOR FOR ADRAR

    Directory of Open Access Journals (Sweden)

    ML CHOUGUI

    2014-12-01

    Full Text Available Adrar is a city in the Sahara desert, in southern Algeria known for its hot and dry climate, where a huge amount of energy is used for air conditioning. The aim of this research is to simulate a single effect lithium bromide–water absorption chiller coupled to a double-glazed flat plate collector to supply the cooling loads for a house of 200m2 in Adrar. The thermal energy is stored in an insulated thermal storage tank. The system was designed to cover a cooling load of 10.39KW for design day of July. Thermodynamic model was established to simulate the absorption cycle. The results have shown that the collector mass flow rate has a negligible effect on the minimum required collector area, but it has a significant effect on the optimum capacity of the storage tank. The minimum required collector area was about 65.3 m2, which could supply the cooling loads for the sunshine hours of the design day for July. The operation of the system has also been considered after sunset by saving solar energy.

  18. Numerical Simulation Study on Flat Plate Solar Collectors in Series - connected System%直流式系统中平板型太阳能集热器数值模拟研究

    Institute of Scientific and Technical Information of China (English)

    倪贝; 丁昀; 杨庆

    2011-01-01

    As it is difficult to solve the problem of unsteady - state heat transfer in theory, study of flat plate solar collectors in series -connected system with intermittent output is conducted by numerical simulation.Under the unsteady - state heat transfer condition, the impact of the diameter and center distance of solar collectors on the instantaneous collector efficiency and water production rate per square meter are discussed respectively.The results show that flat cartridge collector performed high effeciency.And under the same conditions, the larger the diameter of collector is, the higher efficiency will be.These can be used for optimizing design parameters of flat plate solar collectors.%由于非稳态传热问题通过理论计算得到解析解较困难,本文运用数值模拟方法研究定温放水型直流式系统中平板型太阳能集热器的工作状况,讨论了集热器的管径和管中心距在非稳态传热条件下对集热器的效率和每平方米产水量的影响.可得到结论扁盒式集热器具有较高效率;相同条件下,管径越大集热器效率越高.该结果有利于优化直流式平板集热器的设计参数.

  19. Unglazed photovoltaic-thermal solar collector in heat pump systems; Unverglaste photovoltaisch-thermische Kollektoren in Waermepumpensystemen

    Energy Technology Data Exchange (ETDEWEB)

    Bertram, E.; Stegmann, M.; Scheuren, J. [Institut fuer Solarenergieforschung GmbH Hameln/Emmerthal (ISFH), Emmerthal (Germany); Rosinski, C.; Kundmueller, K. [GEFGA mbH und Co. KG, Limburg (Germany)

    2010-07-01

    Photovoltaic-thermal solar collectors simultaneously produce electricity and heat. The desired temperature levels for the electric and thermal utilization commonly are contrary to each other. In combination with heat pump systems, unglazed photovoltaic-thermal solar collectors offer a promising application due to their low temperature level. Under this aspect, unglazed photovoltaic-thermal solar collectors are investigated in simulation and experiment within a research project at the Institute for Solar Energy Research (Hameln/Emmerthal, Federal Republic of Germany). The authors of the contribution under consideration report on results from the ongoing first year of operation of a pilot plant, measurements of performance on photovoltaic-thermal solar collectors and the developed model for an unglazed photovoltaic-thermal solar collector.

  20. Demonstration of Solar Heating and Cooling System using Sorption Integrated Solar Thermal Collectors

    OpenAIRE

    Blackman, Corey; Bales, Chris; Hallström, Olof

    2014-01-01

    Producing cost-competitive small and medium-sized solar cooling systems is currently a significant challenge. Due to system complexity, extensive engineering, design and equipment costs; the installation costs of solar thermal cooling systems are prohibitively high. In efforts to overcome these limitations, a novel sorption heat pump module has been developed and directly integrated into a solar thermal collector. The module comprises a fully encapsulated sorption tube containing hygroscopic ...

  1. Performance Comparison and Analysis of Heating and Ventilation of Two Kinds of Roof Solar Collectors

    Institute of Scientific and Technical Information of China (English)

    翟晓强; 王如竹; 代彦军

    2004-01-01

    Two roof solar collectors (RSCs), conventional single pass RSC and new double pass RSC, were compared. The new roof solar collector, which is formed by integrating a double pass solar air collector with the roof of the building, can be operated more efficiently for space heating in winter, and for natural ventilation in other seasons. To evaluate the performances of the two RSCs for both space heating and natural ventilation, a single traditional Chinese style house, on which the two RSCs will be mounted, was developed. The efficiency of solar energy conversion for the new RSC is higher than that of the single pass one by 10% on average, and the ventilation rate contributed by natural ventilation for the new RSC can be improved to a great extent for most cases, indicating that the new RSC is superior to the single pass one from the viewpoint of both space heating and natural ventilation. The new RSC is more potential for improving indoor thermal environment and energy saving of buildings.

  2. Steady-state heat transfer in transversely heated porous media with application to focused solar energy collectors

    Science.gov (United States)

    Nichols, L. D.

    1976-01-01

    A fluid flowing in a porous medium heated transversely to the fluid flow is considered. This configuration is applicable to a focused solar energy collector for use in an electric power generating system. A fluidized bed can be regarded as a porous medium with special properties. The solutions presented are valid for describing the effectiveness of such a fluidized bed for collecting concentrated solar energy to heat the working fluid of a heat engine. Results indicate the advantage of high thermal conductivity in the transverse direction and high operating temperature of the porous medium.

  3. Solar Air Collectors for Space Heating and Ventilation Applications—Performance and Case Studies under Romanian Climatic Conditions

    OpenAIRE

    Sanda Budea

    2014-01-01

    Solar air collectors have various applications: on the one hand, they can be used for air heating in cold seasons; on the other hand they can be used in summer to evacuate the warm and polluted air from residential, offices, industrial, and commercial buildings. The paper presents experimental results of a solar collector air, under the climatic conditions of the Southeastern Europe. The relationships between the direct solar irradiation, the resulting heat flow, the air velocity at the outle...

  4. Unglazed photovoltaic-thermal collectors in combination with heat pumps and geothermal heat probes; Unverglaste photovoltaisch-thermische Kollektoren in Kombination mit Waermepumpen und Erdsonden

    Energy Technology Data Exchange (ETDEWEB)

    Bertram, E.; Stegmann, M.; Scheuren, J. [Institut fuer Solarenergieforschung GmbH Hameln/Emmerthal (ISFH), Emmerthal (Germany); Rosinski, C.; Kundmueller, K. [GEFGA mbH und Co. KG, Limburg (Germany)

    2010-07-01

    Unglazed Photovoltaic Thermal (PVT) collectors provide very high efficiency for heat and electricity generation at low temperatures. Therefore they are particularly suitable to support the heat source of heat pump systems, where low temperature heat is required. In this combination the PVT collector improves efficiency in two ways - of the heat pump by additional low temperature heat and of the photovoltaic by cooling. Between April and November 2009 an increase of 5% of photovoltaic electricity production and a high collector yield of 380 kWh/(m{sup 2} a) was measured on a pilot system. Of course, the improvement of the PV and heat pump efficiency depends strongly on the thermal PVT collector performance. In this context the performances of four different unglazed PVT collectors were measured and significant differences revealed. The conversion factor without electricity production varies from 0.33 to 0.73. Further, a model for unglazed PVT-collectors was developed. It is based on performance data of En 12975 and IEC 60904 only and considers thermal collector capacity and condensation effects. (orig.)

  5. The multiple layer solar collector

    Science.gov (United States)

    Kenna, J. P.

    1983-01-01

    An analytical model is developed for obtaining numerical solutions for differential equations describing the performance of separate layers in a multiple layer solar collector. The configurations comprises heat transfer fluid entering at the top of the collector and travelling down through several layers. A black absorber plate prevents reemission of thermal radiation. The overall performance is shown to depend on the number of layers, the heat transfer coefficient across each layer, and the absorption properties of the working fluid. It is found that the multiple layer system has a performance inferior to that of flat plate selective surface collectors. Air gaps insulating adjacent layers do not raise the efficiency enough to overcome the relative deficiency.

  6. Effect of solar irradiation on forced convective heat transfer through a nanofluid based direct absorption solar collector

    Science.gov (United States)

    Parvin, Salma; Ahmed, Sajid; Chowdhury, Raju

    2017-06-01

    The present work investigates numerically the convective and radiative heat transfer performance and entropy generation of forced convection through a direct absorption solar collector (DASC). Four different fluids; Cu-water nanofluid, Al2O3-waternanofluid, TiO2-water nanofluid and pure water are used as the working fluid. Entropy production has been taken into account in addition to the collector efficiency and heat transfer enhancement. Penalty finite element method with Galerkin's weighted residual technique is used to solve the governing non-linear partial differential equations. Numerical simulations are performed for the variation of solar irradiation (I). The outcomes are presented in the form of isotherms, average output temperature, the average Nusselt number, collector efficiency, average entropy generation and Bejan number. The results present that the rate of heat transfer and collector efficiency enhance significantly for raising the values of I upto a certain range.

  7. Study on heat collector of the solar system utilizing outdoor air. Experimental results in cases of cold and warm regions; Gaiki donyushiki solar system no shunetsubu ni kansuru kenkyu. Kanreichi to ondanchi ni okeru shunetsu jikken to kosatsu

    Energy Technology Data Exchange (ETDEWEB)

    Komano, S.; Ebara, Y. [OM Solar Association, Shizuoka (Japan); Wada, H. [Wada Building Constructors Co. Ltd., Hokkaido (Japan)

    1996-10-27

    An experiment on heat collection was made in the heat collector of a solar system utilizing outdoor air in cold and warm regions. In this system, outdoor air is heated by the air circulation layer on the roof exposed to solar radiation. The heated air is supplied to the object space for heating and ventilation. In the experiment in a cold region, the heat collection characteristics can be adjusted by putting a baffle plate in the air duct according to the experiment of a glass heat collector. The heat collecting air layer on only the iron roof may leak or freeze in the region subject to coldness or heavy snowfall. Therefore, preheat forms the space of a garret, and the preheat temperature comparatively becomes low. The data in which the heat collection characteristics can be adjusted using only a glass heat collector is required corresponding to the regional situation. In the experiment in a warm region, an experiment was made inclusive of the preheat for which outdoor air is absorbed at the eaves. As a result, the heat collection characteristics of preheat were improved. Moreover, a heat collection temperature of about 60{degree}C was obtained on the heat collection surface including the preheat. 1 ref., 12 figs., 3 tabs.

  8. Performance Evaluation of a Solar Dryer with Finny, Perforated Absorber Plate Collector Equipped with an Air Temperature Control System for Dill Drying

    Directory of Open Access Journals (Sweden)

    M Razmipour

    2015-03-01

    Full Text Available Dill is one of the most important plants in the world because of its medicinal properties and it is widely used as a vegetable in the most parts of Iran. In the present study a new solar dryer with finny, perforated absorber plate collector was utilized to dry fresh dill. The dryer was comprised of a solar collector, a product container, a fan and a drying air temperature controller. The temperature controller was used as a control system to regulate the drying air temperature. Thermal performance of the dryer with finny, perforated solar collector was compared with that of a simple flat plate solar collector at different airflow rates. The effect of drying air temperature at three levels (45, 55 and 65 °C, the product size at three lengths (3, 5 and 7 cm and two different modes of drying (mixed and indirect on the dryer performance was investigated. The results showed that the finny, perforated absorber plate solar collector could improve the thermal efficiency about 11% in comparison with the flat plate collector and the highest thermal efficiency was achieved at the maximum airflow rate. Meanwhile, increasing the air temperature and decreasing the product size caused a significant reduction in energy consumption. Solar fraction reduced by increasing the air temperature. Finally a maximum dryer efficiency of 70% was observed at air temperature of 65 oC, product size of 3 cm with mixed mode drying.

  9. A Structural Design of Insulated and Heat Conduction Ceramic Plate Used in Two Stage Depressed Collectors%一种应用于两级降压收集极的绝缘导热瓷件的结构设计

    Institute of Scientific and Technical Information of China (English)

    骆岷; 杨定义; 周明干

    2012-01-01

    A structural design of insulated and heat conduction ceramic plate,which think about material choice, insulated space and so on. And the design results used in practice.%介绍了一种绝缘导热瓷件的结构设计,从材料的选择、绝缘距离的考虑等方面进行了考虑,给出了设计结果及实际应用情况.

  10. Wind effects on convective heat loss from a cavity receiver for a parabolic concentrating solar collector

    Energy Technology Data Exchange (ETDEWEB)

    Ma, R.Y. [California State Polytechnic Univ., Pomoma, CA (United States). Dept. of Mechanical Engineering

    1993-09-01

    Tests were performed to determine the convective heat loss characteristics of a cavity receiver for a parabolid dish concentrating solar collector for various tilt angles and wind speeds of 0-24 mph. Natural (no wind) convective heat loss from the receiver is the highest for a horizontal receiver orientation and negligible with the reveler facing straight down. Convection from the receiver is substantially increased by the presence of side-on wind for all receiver tilt angles. For head-on wind, convective heat loss with the receiver facing straight down is approximately the same as that for side-on wind. Overall it was found that for wind speeds of 20--24 mph, convective heat loss from the receiver can be as much as three times that occurring without wind.

  11. Optimization of Serial Combined System of Ground-Coupled Heat Pump and Solar Collector

    Institute of Scientific and Technical Information of China (English)

    ZHAO Jun; CHEN Yan; LU Suzhen; CUI Junkui

    2009-01-01

    A mathematical optimization model was set up for a ground-solar combined system based on in-situ experimental results,in which the solar collector was combined serially with a ground-coupled heat pump(GCHP).The universal optimal equations were solved by the constrained variable metric method considering both the performance and economics.Then the model was applied to a specific case concerning an actual solar assisted GCHP system for space heating.The results indicated a system coefficient of performance(COP)of 3.9 for the optimal method under the seriaI heating mode,and 3.2 for the conventional one.In addition,the optimum solution also showed advantages in energy and cost saving.1eading to a 16.7%improvement in the heat pump performance at 17.2%less energy consumption and 11.8%lower annual cost,respectively.

  12. Simulation, construction and testing of a two-cylinder solar Stirling engine powered by a flat-plate solar collector without regenerator

    Energy Technology Data Exchange (ETDEWEB)

    Tavakolpour, Ali Reza; Zomorodian, Ali [Department of Mechanics of Farm Machinery Engineering, Shiraz University, Shiraz (Iran); Akbar Golneshan, Ali [Department of Mechanical Engineering, Shiraz University, Shiraz (Iran)

    2008-01-15

    In this research, a gamma-type, low-temperature differential (LTD) solar Stirling engine with two cylinders was modeled, constructed and primarily tested. A flat-plate solar collector was employed as an in-built heat source, thus the system design was based on a temperature difference of 80{sup o}C. The principles of thermodynamics as well as Schmidt theory were adapted to use for modeling the engine. To simulate the system some computer programs were written to analyze the models and the optimized parameters of the engine design were determined. The optimized compression ratio was computed to be 12.5 for solar application according to the mean collector temperature of 100{sup o}C and sink temperature of 20{sup o}C. The corresponding theoretical efficiency of the engine for the mentioned designed parameters was calculated to be 0.012 for zero regenerator efficiency. Proposed engine dimensions are as follows: power piston stroke 0.044 m, power piston diameter 0.13 m, displacer stroke 0.055 m and the displacer diameter 0.41 m. Finally, the engine was tested. The results indicated that at mean collector temperature of 110{sup o}C and sink temperature of 25{sup o}C, the engine produced a maximum brake power of 0.27 W at 14 rpm. The mean engine speed was about 30 rpm at solar radiation intensity of 900 W/m{sup 2} and without load. The indicated power was computed to be 1.2 W at 30 rpm. (author)

  13. Experimental Analysis of Serpentine-flow Flat-plate Solar Collector%蛇形管平板式太阳能集热器的试验研究

    Institute of Scientific and Technical Information of China (English)

    李俊贤; 王辉涛; 王华; 包桂蓉

    2011-01-01

    A serpentine-flow flat-plate solar collector of small volume and large temperature difference is designed and developed in order to explore the fiat-plate solar collector used in high temperature situation. And experiment of stagnation and instantaneous efficiency is carried out. The results shown that stagnation temperature can reach 170.2 ℃ and heat loss coefficient is 5. 239 W/( m2 · ℃ ). Efficiency of solar collector between 52% —55% when inlet temperature of working fluid is 70 ℃. By comparison the temperature trend of various parts of the collector the corrective measure is proposed to improve performance of serpentine-flow fiat-plate solar collector in high temperature conditions.%为了探寻一种在中高温场合使用的平板式太阳能集热器,设计和开发了小流量、大温差的蛇形管平板式太阳能集热器,并进行了空晒试验和瞬时效率试验.试验结果表明:集热器的空晒温度可达170.2℃,热损系数为5.239 W/(m2·℃),载热工质进口温度70℃时效率52%-55%.通过对集热器各部分温度变化趋势的比较,提出改进措施,以提高蛇形管平板式集热器在中高温工况下的集热性能.

  14. Performance Evaluation of a Nanofluid-Based Direct Absorption Solar Collector with Parabolic Trough Concentrator

    OpenAIRE

    Xu, Guoying; Chen, Wei; Deng, Shiming; Zhang, Xiaosong; Zhao, Sainan

    2015-01-01

    Application of solar collectors for hot water supply, space heating, and cooling plays a significant role in reducing building energy consumption. For conventional solar collectors, solar radiation is absorbed by spectral selective coating on the collectors’ tube/plate wall. The poor durability of the coating can lead to an increased manufacturing cost and unreliability for a solar collector operated at a higher temperature. Therefore, a novel nanofluid-based direct absorption solar collector...

  15. Experimental investigation of heat transfer and effectiveness in corrugated plate heat exchangers having different chevron angles

    Science.gov (United States)

    Kılıç, Bayram; İpek, Osman

    2017-02-01

    In this study, heat transfer rate and effectiveness of corrugated plate heat exchangers having different chevron angles were investigated experimentally. Chevron angles of plate heat exchangers are β = 30° and β = 60°. For this purpose, experimentally heating system used plate heat exchanger was designed and constructed. Thermodynamic analysis of corrugated plate heat exchangers having different chevron angles were carried out. The heat transfer rate and effectiveness values are calculated. The experimental results are shown that heat transfer rate and effectiveness values for β = 60° is higher than that of the other. Obtained experimental results were graphically presented.

  16. Buoyancy effects on thermal behavior of a flat-plate solar collector

    DEFF Research Database (Denmark)

    Fan, Jianhua; Furbo, Simon

    2008-01-01

    Theoretical and experimental investigations of the flow and temperature distribution in a 12.53 m(2) solar collector panel with an absorber consisting of two vertical manifolds interconnected by 16 parallel horizontal fins have been carried out. The investigations are focused on overheating and b...

  17. Design approaches for solar industrial process-heat systems: nontracking and line-focus collector technologies

    Energy Technology Data Exchange (ETDEWEB)

    Kutscher, C.F.; Davenport, R.L.; Dougherty, D.A.; Gee, R.C.; Masterson, P.M.; May, E.K.

    1982-08-01

    The design methodology for solar industrial process heat systems is described, and an overview is given of the use of solar energy in industry. A way to determine whether solar energy makes sense for a particular application is described. The basic system configurations used to supply hot water or steam are discussed, and computer-generated graphs are supplied that allow the user to select a collector type. Detailed energy calculations are provided, including the effects of thermal losses and storage. The selection of subsystem components is described, and control systems, installation and start-up details, economics, and safety and environmental issues are explained. (LEW)

  18. Ceramic Plate Solar Collector and Column Pile Structure Ceramic Solar Roof%陶瓷太阳板与锚桩结构陶瓷太阳能房顶的应用

    Institute of Scientific and Technical Information of China (English)

    孙启正; 许建华

    2012-01-01

    陶瓷太阳板以普通瓷土、工业废弃物为原料,具有制造工艺简单、生产耗能少、成本低、寿命长、效率高的优点;锚桩陶瓷太阳能房顶与原房顶共用结构层、保温层、防水层,结构简单、与建筑一体化、与建筑同寿命,为建筑物提供热水、取暖、空调的功能。%Ceramic plate solar collector, manufactured by common porcelain clay and industrial waste,has a lot of advantages such as simple process,low energy consumption,low cost,long life, high efficiency etc. Ceramic plate solar collector roof share the structure layer,insulation layer and waterproof layer with the origin roof. The roof has a simple structure, integration and same life with the building. Ceramic plate solar collector roof can supply hot water, heating and air condition to the building.

  19. Performance Investigation of Plate Type Heat Exchanger (A Case Study

    Directory of Open Access Journals (Sweden)

    Simarpreet Singh

    2014-04-01

    Full Text Available Heat exchanger is a thermodynamic system which is most commonly used in the process industry for exchanging heat energy between the fluids. flowing in the same or opposite direction. It is desired that effectiveness of heat exchanger should remain as large as possible. Heat exchanger's performance may be improved by the addition of fins or corrugations. These investigations include design of plate type heat exchanger, heat transfer enhancement, flow phenomenon and cleanliness factor. In process plants, this type of heat exchange is generally used for recovering heat content of exhaust steam. However, with the flow of fluid for a long period, fouling occurs on the plate surface. Therefore, it is required to investigate the effect of fouling, wherever the heat exchanger is installed. An extensive experimental investigation has been carried out under clean and dirty condition of the said plate type heat exchanger. Heat transfer and flow data were collected in experiment. From collected data heat transfer rate, overall heat transfer coefficient, fouling factor and cleanliness factor were evaluated. Based upon the cleanliness factor data, next date of cleanliness for plate type heat exchanger was predicted. It is felt that the outcome of the present research work may be quite useful for efficient operation of plate type heat exchanger installed in Process plants.

  20. Experiment and simulation for convective heat transfer in all-glass evacuated tube solar collectors%全玻璃真空管太阳能集热器对流换热试验与模拟

    Institute of Scientific and Technical Information of China (English)

    张涛; 韩吉田; 田瑞; 于泽庭

    2016-01-01

    以可再生能源总能系统为研究背景,通过搭建太阳能辅助燃料电池试验平台,逐步完成不同涂层材料、内置导流板太阳能集热器自然对流试验研究;在试验验证基础上,分别建立太阳能集热器自然对流和强迫对流三维数学模型,应用场协同和火积理论分析流动和传热数据。自然对流研究表明,吸收率在0.95~1.0、发射率在0.06~0.16时,随吸收率升高,发射率降低,热效率升高1.71%,火积增量逐渐增大;加装导流板后,真空管内部混流消失,底部流动得到强化,实验热效率提高2.17%;确定全玻璃真空管热水器导流板合理板厚为2 mm,合理板长为距离真空管底部60~100 mm,合理位置为中心线以上16~20 mm;强迫对流研究表明,横双排集热器雷诺和努赛尔数、火积增量均高于竖单排集热器,火积耗散低于竖单排集热器。确定太阳能辅助燃料电池集热场在中低温条件下,自然对流采用内置导流板集热器,强迫对流采用横双排集热器。%The experimental study of natural convection for solar collectors with different coating materials and being equipped with guide plate is carried out step by step through the experimental platform of solar-assisted fuel cells under the research background of renewable total energy systems, which mainly include solar energy comprehensive utilization, solid oxide fuel cells, gas turbine and Kalina refrigeration cycle. The three-dimensional mathematical model on natural convection and forced convection of solar collectors is established to study the flow and heat transfer data with the field synergy and entransy principle on the basis of experimental verification. The natural convection results show that the thermal efficiency and the entransy increment rise gradually with the absorption rate increasing from 0.95 to 1.0 and the emission rate decreasing from 0.06 to 0.16, and the thermal

  1. DEVELOPMENT OF A MATHEMATICAL MODEL OF INSTALLATION OF SELF-CONTAINED HEATING BASED ON SOLAR THERMAL COLLECTOR

    OpenAIRE

    Kartashev, Alexander; Safonov, Evgeniy; Kartasheva, Marina

    2011-01-01

    The mathematical model describing the operation of the installation of selfcontained heating and hot water supply based on solar thermal collector with the system of accumulation of heat energy, monitoring and control of thermal conditions of building is developed. Modeling of operation of the installation in different conditions is realized.

  2. Optimization of systems with the combination of ground-source heat pump and solar collectors in dwellings

    DEFF Research Database (Denmark)

    Kjellsson, Elisabeth; Hellström, Göran; Perers, Bengt

    2010-01-01

    The use of ground-source heat pumps for heating and domestic hot water in dwellings is common in Sweden. The combination with solar collectors has been introduced to reduce the electricity demand in the system. In order to analyze different systems with combinations of solar collectors and ground......-source heat pumps, computer simulations have been carried out with the simulation program TRNSYS. Large differences were found between the system alternatives. The optimal design is when solar heat produces domestic hot water during summertime and recharges the borehole during wintertime. The advantage...... is related to the rate of heat extraction from the borehole as well as the overall design of the system. The demand of electricity may increase with solar recharging, because of the increased operating time of the circulation pumps. Another advantage with solar heat in combination with heat pumps is when...

  3. Evacuated tubular collector utilizing a heat pipe. Progress report, May 1 1975--August 31, 1975

    Energy Technology Data Exchange (ETDEWEB)

    Ortabasi, U.; Fehlner, F.P.

    1975-01-01

    Research and development activities performed by the Corning Glass Works solar group during the period from May 1, 1975 to August 31, 1975 are reported. The analytical studies encompassed optical modeling of a modified cusp reflector, fresnel losses from tubular enclosures as a function of orientation, preliminary work on a digital Monte-Carlo Ray Tracing Computer Code and the determination of U/sub L/ losses as a function of vacuum level and temperature of the absorber. Compatible enclosure materials, wicks and working fluids were selected to assemble heat pipes for use as solar collector absorbers. Cusp reflectors with good accuracy were fabricated from various commercial bright aluminum sheet and their optical properties determined. Evacuation techniques were developed and special bake-out procedures were worked out to assemble the evacuated tubular collectors. The work on selective coatings narrowed down the field of potential absorber films to ''black chrome'' which has good stability in vacuum and the necessary ..cap alpha../epsilon value. Six different heat pipes and one flow-through absorber were fabricated and were partially characterized for thermal performance. Indoor and outdoor test facilities were completed and calibrated within proposed NBS standards. They are now available for parametric as well as true-life experiments with solar radiation.

  4. Solar Air Collectors for Space Heating and Ventilation Applications—Performance and Case Studies under Romanian Climatic Conditions

    Directory of Open Access Journals (Sweden)

    Sanda Budea

    2014-06-01

    Full Text Available Solar air collectors have various applications: on the one hand, they can be used for air heating in cold seasons; on the other hand they can be used in summer to evacuate the warm and polluted air from residential, offices, industrial, and commercial buildings. The paper presents experimental results of a solar collector air, under the climatic conditions of the Southeastern Europe. The relationships between the direct solar irradiation, the resulting heat flow, the air velocity at the outlet, the air flow rate, the nominal regime of the collector and the efficiency of conversion of solar energy into thermal energy are all highlighted. Thus, it was shown that after a maximum 50 min, solar air collectors, with baffles and double air passage can reach over 50% efficiency for solar irradiation of 900–1000 W/m2. The article also presents a mathematical model and the results of a computational program that allows sizing solar collectors for the transfer of air, with the purpose of improving the natural ventilation of buildings. The article is completed with case studies, sizing the area to be covered with solar collectors, to ensure ventilation of a house with two floors or for an office building. In addition, the ACH (air change per hour coefficient was calculated and compared.

  5. Development of flat-plate solar thermal collectors equipped with aerogel sandwiched absorber

    Energy Technology Data Exchange (ETDEWEB)

    Goto, Yusuke; Izumi, Hiroaki; Aizawa, Mamoru [Dynax Corp. (Japan); Yugami, Hiroo [Graduate School of Engineering, Tohoku Univ. (Japan)

    2004-07-01

    It is important to utilize the solar energy efficiently. However, conventional solar thermal collectors have some drawbacks of high cost, heavy weight and low temperature output. These drawbacks prevent from spreading of the market of solar thermal collectors, especially in Japan. To find a solution to the problems, we propose an absorber / aerogel one-piece structure for high temperature solar thermal collectors. TiOxNy and silica aerogel were employed as a selectively solar-absorbing coating of absorber and as an optically transparent thermal insulator, respectively. Selectively solar-absorbing coatings must show lower reflectance and lower emittance. We have developed selectively solar-absorbing coatings of which optical property was {alpha} = 98.5, {epsilon} = 3 %. Wet coating of newly designed TiOxNy precursor enabled fabricating selectively solar-absorbing coatings, easily. Shrinkage of silica aerogel had to be minimized to produce an absorber / aerogel one-piece structure. Selectively solar-absorbing coatings and silica aerogel were prepared via sol-gel processing. (orig.)

  6. Plates of the dinosaur stegosaurus: forced convection heat loss fins?

    Science.gov (United States)

    Farlow, J O; Thompson, C V; Rosner, D E

    1976-06-11

    It is suggested that the plates along the arched back and tail of Stegosaurus served an important thermoregulatory function as forced convection "fins." Wind tunnel experiments on finned models, internal heat conduction calculations, and direct observations of the morphology and internal structure of stegosaur plates support this hypothesis, demonstrating the comparative effectiveness of the plates as heat dissipaters, controllable through input blood flow rate, temperature, and body orientation (with respect to wind).

  7. Effects of Key Parameters on Thermal Performance of Solar Flat-Plate Collector%太阳能平板集热器关键参数对其热性能的影响

    Institute of Scientific and Technical Information of China (English)

    车永毅; 厚彩琴

    2016-01-01

    为了提升太阳能在建筑能源供给体系中的比重,形式多样的太阳能集热设备及其系统在建筑领域得到了广泛应用。基于机理分析法,建立了具有单层玻璃盖板的管板式太阳能平板集热器的稳态传热模型。并且针对集热管间距、集热管内径、工质入口温度和工质质量流量等关键参数对集热器集热效率的影响特性进行了数值模拟与分析。结果表明,建立的该稳态传热模型是可行的;此外,在其余参数值保持不变的情况下,减小集热管间距或增加集热管内径均可使集热器瞬时效率增大;增大工质入口温度会导致集热器瞬时效率下降;而增大工质质量流量会提升集热器瞬时效率。这些结论对于太阳能平板集热器在太阳能建筑一体化的实际应用中,具有一定的参考作用。%In order to improve the proportion of solar energy in building energy supply system, various forms of solar heat collection equipment and systems in the construction field has been widely used. Based on the mechanism analysis method, one steady-state heat transfer model of the single glass cover flat-plate collector is built. The numerical simulation and analysis of the effect of the key parameters including col-lector tube spacing, collector tube diameter, and inlet temperature and inlet mass flow rate of the working fluid on heat collection efficiency of the collector is carried out. The results show that the steady-state heat transfer model is feasible;and in the case of the same parameters, either reducing the collector tube spacing or increasing the collector tube diameter can increase the instantaneous efficiency of the collector; the instantaneous efficiency of the collector decline with the increase of inlet temperature of the working fluid. However, increasing the mass flow rate at the entrance can improve the instantaneous efficiency of the collector. These conclusions have a certain

  8. Development and validation of a detailed TRNSYS-Matlab model for large solar collector fields for district heating applications

    DEFF Research Database (Denmark)

    Bava, Federico; Furbo, Simon

    2017-01-01

    This study describes the development of a detailed TRNSYS-Matlab model to simulate the behavior of a large solar collector field for district heating application. The model includes and investigates aspects which are not always considered by simpler models, such as flow distribution in the differ......This study describes the development of a detailed TRNSYS-Matlab model to simulate the behavior of a large solar collector field for district heating application. The model includes and investigates aspects which are not always considered by simpler models, such as flow distribution...

  9. Diseño de un colector solar de placa plana; Design of a Solar Flat Plate Collector

    Directory of Open Access Journals (Sweden)

    Jeovany Rafael Rodríguez Mejía

    2015-12-01

    Full Text Available En el presente artículo se integra el uso de un software de diseño mecánico y un algoritmo de simulación de la operación de un colector solar de placa plana, con el objetivo de simplificar el proceso de diseño y manufactura de este último. Se exponen los resultados de la simulación de la operación del colector solar considerando diferentes combinaciones en los parámetros de los materiales utilizados, tales como sus propiedades y características físico químicas, además de la variación de las dimensiones del sistema adiseñar. Finalmente en el artículo se evalúa la operación de un colector solar para las condiciones climatológicas típicas de la irradiancia, velocidad de viento y temperatura ambiente a partir de una serie de curvas sinusoidales, típicas de Cuba, validándose la viabilidad del algoritmo como apoyo en la etapa de diseño y selección de materiales.In this article the use of mechanical design software and an algorithm for simulating the operation of a flat plate solar collector, with the objective of simplifying the process of design and manufacture of the latter isintegrated. The simulation results of the operation of the solar collector considering different combinations in the parameters of the materials used, such as its physicochemical properties and features in addition to thevariation of the dimensions of the system design are set. The article finally evaluates the operation of a solar collector for typical climatic conditions of irradiance, wind speed and ambient temperature from a series ofsinusoidal, typical Cuba curves is evaluated, validating the feasibility of the algorithm as support in step design and material selection.

  10. Nitrite/nitrate detection in serum based on dual-plate generator-collector currents in a microtrench.

    Science.gov (United States)

    Gross, Andrew J; Holmes, Stephanie; Dale, Sara E C; Smallwood, Miranda J; Green, Stephen J; Winlove, C Peter; Benjamin, Nigel; Winyard, Paul G; Marken, Frank

    2015-01-01

    A dual-electrode sensor is developed for rapid detection of nitrite/nitrate at micromolar levels in phosphate buffer media and in dilute horse serum without additional sample pre-treatment. A generator-collector configuration is employed so that on one electrode nitrate is reduced to nitrite and on the second electrode nitrite is oxidised back to nitrate. The resulting redox cycle gives rise to a specific and enhanced current signal which is exploited for sensitive and reliable measurement of nitrite/nitrate in the presence of oxygen. The electrode design is based on a dual-plate microtrench (approximately 15 µm inter-electrode gap) fabricated from gold-coated glass and with a nano-silver catalyst for the reduction of nitrate. Fine tuning of the phosphate buffer pH is crucial for maximising collector current signals whilst minimising unwanted gold surface oxidation. A limit of detection of 24 μM nitrate and a linear concentration range of 200-1400 μM is reported for the microtrench sensor in phosphate buffer and dilute horse serum. Relative standard deviations for repeat measurements were in the range 1.8-6.9% (n=3) indicating good repeatability in both aqueous and biological media. Preliminary method validation against the standard chemiluminescence method used in medical laboratories is reported for nitrate analysis in serum.

  11. Laminar Natural Convective Heat Transfer in the Enclosed Evacuated Collector Tube with East—West Symmetric Heat Input

    Institute of Scientific and Technical Information of China (English)

    ZhangHeng-Yun; GeXin-Shi

    1997-01-01

    Heat transfer in the evacuated collector tube is a three-dimensional laminar natural convection problem driven by buoyancy.Because of its complexity,no effective theoretical model is available despite of limited experimental work which is confined to one aspect.The present work aims to depict the convective heat transfer inside a two-ended inclined tube with East-West symmetric heat input using numerical methods,Based on reasonable assumptions,governing equations of the inside fluid are established.The corresponding discretizated equations are solved by emplogying numerical metholds.The calculated results are displayed for velocity and temperature profiles on different cross-sectional plasnes.which present the flow pattern characterized by upflow and downflow along the axial direction and adherent flow along the peripheral direction,and the heat transfer rpocess from the wall to the center,Furthermore,the transient Nusselt number and average temperature level are shown and discussed.Finally,the parametric effects of the tube radius and the heat input on the flow and heat transfer are also given.

  12. Nongray-radiative and convective-conductive thermal coupling in Teflon-glazed, selective-black, flat-plate solar collectors

    Science.gov (United States)

    Edwards, D. K.; Rhee, S. J.

    1984-05-01

    An analysis is presented comparing Teflon film with glass for the inner glazing of a double-glazed selective-black, flat-plate solar collector. The effect of spacing between glazings and between the inner glazing and absorber plate is examined. It is shown that a 12.5-micron Teflon film is superior to glass for the inner glazing of a selective-black collector, because the advantage of its high solar transparency overwhelms the disadvantage of its infrared transparency. A too-small spacing between a selective-black absorber and its inner cover short-circuits the desirable thermal radiation resistance offered by a selective-black absorber plate. Account is taken of spectral variations in the radiation properties of glass, Teflon, and the absorber plate. Allowance is made for the fact that critical Rayleigh number is lower for a plastic film inner glazing than for a glass one.

  13. Modelling of Split Condenser Heat Pump with Limited Set of Plate Heat Exchanger Dimensions

    DEFF Research Database (Denmark)

    Christensen, Stefan Wuust; Elmegaard, Brian; Markussen, Wiebke Brix

    2017-01-01

    This paper presents a numerical study of optimal plate dimensions in a split condenser heat pump (SCHP), using ammonia as refrigerant. The SCHP setup differs from a traditional heat pump (THP) setup in the way that two separate water streams on the secondary side of the condenser are heated...... in parallel to different temperature levels, whereas only one stream is heated in a THP. The length/width ratio of the plate heat exchangers on the high pressure side of a SCHP was investigated to find the optimal plate dimensions with respect to minimum area of the heat exchangers. The total heat exchanger...... area was found to decrease with an increasing length/width ratio of the plates. The marginal change in heat exchanger area was shown to be less significant for heat exchangers with high length/width ratios. In practice only a limited number of plate dimensions are available and feasible...

  14. Thermal performance of solar district heating plants in Denmark

    DEFF Research Database (Denmark)

    Furbo, Simon; Perers, Bengt; Bava, Federico

    2014-01-01

    The market for solar heating plants connected to district heating systems is expanding rapidly in Denmark. It is expected that by the end of 2014 the 10 largest solar heating plants in Europe will be located in Denmark. Measurements from 23 Danish solar heating plants, all based on flat plate solar...... collectors mounted on the ground, shows measured yearly thermal performances of the solar heating plants placed in the interval from 313 kWh/m² collector to 493 kWh/m² collector with averages for all plants of 411 kWh/m² collector for 2012 and 450 kWh/m² collector for 2013. Theoretical calculations show...... of the cost/performance ratio for solar collector fields, both with flat plate collectors and with concentrating tracking solar collectors. It is recommended to continue monitoring and analysis of all large solar heating plants to document the reliability of the solar heating plants. It is also recommended...

  15. Numerical Methods for Plate Forming by Line Heating

    DEFF Research Database (Denmark)

    Clausen, Henrik Bisgaard

    2000-01-01

    Line heating is the process of forming originally flat plates into a desired shape by means of heat treatment. Parameter studies are carried out on a finite element model to provide knowledge of how the process behaves with varying heating conditions. For verification purposes, experiments are ca...... are carried out; one set of experiments investigates the actual heat flux distribution from a gas torch and another verifies the validty of the FE calculations. Finally, a method to predict the heating pattern is described....

  16. Investigation of Brazed Plate Heat Exchangers With Variable Chevron Angles

    Directory of Open Access Journals (Sweden)

    S. Muthuraman

    2013-08-01

    Full Text Available - Experiments to measure the condensation heat transfer coefficient and the pressure drop in brazed plate heat exchangers (BPHEs were performed with the refrigerants R410A and R22. Brazed plate heat exchangers with different chevron angles of 45°, 35°, and 20° were used. Varying the mass flux, the condensation temperature, and the vapor quality of the refrigerant, we measured the condensation heat transfer coefficient and the pressure drops. Both the heat transfer coefficient and the pressure drop increased proportionally with the mass flux and the vapor quality and inversely with the condensation temperature and the chevron angle.

  17. Air bubble-induced detachment of positively and negatively charged polystyrene particles from collector surfaces in a parallel-plate flow chamber

    NARCIS (Netherlands)

    Gomez-Suarez, C; Van der Mei, HC; Busscher, HJ

    2000-01-01

    Electrostatic interactions between colloidal particles and collector surfaces were found tcr be important in particle detachment as induced by the passage of air bubbles in a parallel-plate Row chamber. Electrostatic interactions between adhering particles and passing air bubbles, however, a-ere

  18. Detachment of colloidal particles from collector surfaces with different electrostatic charge and hydrophobicity by attachment to air bubbles in a parallel plate flow chamber

    NARCIS (Netherlands)

    Suarez, CG; van der Mei, HC; Busscher, HJ

    1999-01-01

    The detachment of polystyrene particles adhering to collector surfaces with different electrostatic charge and hydrophobicity by attachment to a passing air bubble has been studied in a parallel plate flow chamber. Particle detachment decreased linearly with increasing air bubble velocity and

  19. Air bubble-induced detachment of positively and negatively charged polystyrene particles from collector surfaces in a parallel-plate flow chamber

    NARCIS (Netherlands)

    Gomez-Suarez, C; Van der Mei, HC; Busscher, HJ

    2000-01-01

    Electrostatic interactions between colloidal particles and collector surfaces were found tcr be important in particle detachment as induced by the passage of air bubbles in a parallel-plate Row chamber. Electrostatic interactions between adhering particles and passing air bubbles, however, a-ere fou

  20. Detachment of colloidal particles from collector surfaces with different electrostatic charge and hydrophobicity by attachment to air bubbles in a parallel plate flow chamber

    NARCIS (Netherlands)

    Suarez, CG; van der Mei, HC; Busscher, HJ

    1999-01-01

    The detachment of polystyrene particles adhering to collector surfaces with different electrostatic charge and hydrophobicity by attachment to a passing air bubble has been studied in a parallel plate flow chamber. Particle detachment decreased linearly with increasing air bubble velocity and decrea

  1. Line Heat-Source Guarded Hot Plate

    Data.gov (United States)

    Federal Laboratory Consortium — Description: The 1-meter guarded hot-plate apparatus measures thermal conductivity of building insulation. This facility provides for absolute measurement of thermal...

  2. Line Heat-Source Guarded Hot Plate

    Data.gov (United States)

    Federal Laboratory Consortium — Description:The 1-meter guarded hot-plate apparatus measures thermal conductivity of building insulation. This facility provides for absolute measurement of thermal...

  3. Use of buried collector heat pumps in space heating and cooling; Utilisation en chauffage et en refraichissement des thermopompes a capteurs enterres

    Energy Technology Data Exchange (ETDEWEB)

    Bernier, J. [Societe SYREC, 22 - Dinan (France)

    1997-12-31

    This paper presents a comparative evaluation of the seasonal thermal performances of the different types of heat pumps with buried collectors: ground/ground type, water-glycol water type, and ground/water type. The different systems are also compared with respect to their adaptation to reversibility. A heat pump system for sanitary hot water production is also presented. (J.S.)

  4. Output feedback control of heat transport mechanisms in parabolic distributed solar collectors

    KAUST Repository

    Elmetennani, Shahrazed

    2016-08-05

    This paper presents an output feedback control for distributed parabolic solar collectors. The controller aims at forcing the outlet temperature to track a desired reference in order to manage the produced heat despite the external disturbances. The proposed control strategy is derived using the distributed physical model of the system to avoid the loss of information due to model approximation schemes. The system dynamics are driven to follow reference dynamics defined by a transport equation with a constant velocity, which allows to control the transient behavior and the response time of the closed loop. The designed controller depends only on the accessible measured variables which makes it easy for real time implementation and useful for industrial plants. Simulation results show the efficiency of the reference tracking closed loop under different working conditions.

  5. An Alternative Algorithm for Optimal Design of Plate Heat Exchangers

    Directory of Open Access Journals (Sweden)

    Seyyed Morteza Javid

    2015-02-01

    Full Text Available Due to the complex geometry of plate heat exchangers and thus a large number of variables affecting the performance of the exchangers, the design of these types of exchangers is quiet difficult. However, unlike the shell and tube heat exchangers which contain available data of design procedures, the design of plate heat exchanger is a monopoly of some certain manufacturing companies that make the problem even worse. In this paper, the objective is to minimize the number of plates in plate heat exchanger; in order to achieve that, a simple and yet efficient mathematical model is introduced for determination of the pressure drop and heat capacity of a plate heat exchanger in single- and multipass state and also a program was defined for determination of optimal solution based on this simple mathematical model for given operational constraints and plate type. In the end, the optimal solution will be compared to the answer of CAS200 commercial software and also it is shown that the effect of the start and end plates and transverse distribution in optimal solution is considerable.

  6. Transpired Solar Collector at NREL's Waste Handling Facility Uses Solar Energy to Heat Ventilation Air (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2010-09-01

    The transpired solar collector was installed on NREL's Waste handling Facility (WHF) in 1990 to preheat ventilation air. The electrically heated WHF was an ideal candidate for the this technology - requiring a ventilation rate of 3,000 cubic feet per meter to maintain safe indoor conditions.

  7. Modeling natural convection heat transfer from perforated plates

    Institute of Scientific and Technical Information of China (English)

    Zan WU; Wei LI; Zhi-jian SUN; Rong-hua HONG

    2012-01-01

    Staggered pattern perforations are introduced to isolated isothermal plates,vertical parallel isothermal plates,and vertical rectangular isothermal fins under natural convection conditions.The performance of perforations was evaluated theoretically based on existing correlations by considering effects of ratios of open area,inclined angles,and other geometric parameters.It was found that staggered pattern perforations can increase the total heat transfer rate for isolated isothermal plates and vertical parallel plates,with low ratios of plate height to wall-to-wall spacing (H/s),by a factor of 1.07 to 1.21,while only by a factor of 1.03 to 1.07 for vertical rectangular isothermal fins,and the magnitude of enhancement is proportional to the ratio of open area.However,staggered pattern perforations are detrimental to heat transfer enhancement of vertical parallel plates with large H/s ratios.

  8. Performance evaluation of a liquid solar collector

    Science.gov (United States)

    1979-01-01

    Report describes thermal performance and structural-load tests on commercial single glazed flat-plate solar collector with gross area of 63.5 sq ft that uses water as heat-transfer medium. Report documents test instrumentation and procedures and presents data as tables and graphs. Results are analyzed by standard data-reduction methods.

  9. Simulation Studies on A Cross Flow Plate Fin Heat Exchanger

    Directory of Open Access Journals (Sweden)

    M. Thirumarimurugan

    2008-01-01

    Full Text Available Compact heat exchangers which were initially developed for the aerospace industries in the1940s have been considerably improved in the past few years. The main reasons for the goodperformance of compact heat exchangers are their special design which includes turbulent which inturn use high heat transfer coefficient and resists fouling, and maximum temperature driving forcebetween the hot and cold fluids. Numerous types use special enhancement techniques to achieve therequired heat transfer in smaller plot areas and, in many cases, less initial investment. One such type ofcompact heat exchanger is the Plate-fin heat exchanger. The complexity of compact heat exchangerdesign equations results from the exchangers unique ability to transfer heat between multiple processstreams and a wide array of possible flow configurations. This paper presents the performanceevaluation of cross flow plate fin heat exchanger with several different Gas-Liquid systems.Experimental results such as exchanger effectiveness, overall heat transfer coefficients were calculatedfor the flow systems of Cross flow Heat Exchangers. A steady state model for the outlet temperature ofboth the cold and hot fluid and overall heat transfer coefficient of a plate-fin cross flow heat exchangerwas developed and simulated using MATLAB, which was verified with the experiments conducted.

  10. Theoretical and experimental investigations of Chinese evacuated tubular solar collectors

    DEFF Research Database (Denmark)

    Qin, Lin; Furbo, Simon

    1999-01-01

    Four different marketed Chinese evacuated tubular solar collectors have been investigated both theoretically and experimentally. The advantages of the investigated solar collectors compared to normal flat plate collectors were elucidated.......Four different marketed Chinese evacuated tubular solar collectors have been investigated both theoretically and experimentally. The advantages of the investigated solar collectors compared to normal flat plate collectors were elucidated....

  11. Spiral multiple-effect diffusion solar still coupled with vacuum-tube collector and heat pipe

    KAUST Repository

    Huang, Bin-Juine

    2015-04-01

    © 2015 Elsevier B.V. A novel solar still with spiral-shape multiple-effect diffusion unit is developed in the present study. The test results of a 14-effect unit coupled with vacuum-tube solar collector (absorber area 1.08m2) show that the highest daily pure water production is 40.6kgd-1. The measured highest productivity based on the area of glass cover, solar absorber, and evaporating surface is 34.7, 40.6, and 7.96kgm-2d-1, respectively, which are much higher than the published results. The measured solar distillation efficiency is 2.0-3.5. The performance enhancement results mainly from the lateral diffusion process in the spiraled still cell. The vapor flow generated by heat input can flow freely and laterally through the spiral channel down to the end when solar heat input is high. Besides, the larger evaporating and condensing area at the outer cell may increase heat and mass transfer at the outer cell.

  12. Exergetic and Thermoeconomic Analyses of Solar Air Heating Processes Using a Parabolic Trough Collector

    Directory of Open Access Journals (Sweden)

    Miguel Ángel Hernández-Román

    2014-08-01

    Full Text Available This paper presents a theoretical and practical analysis of the application of the thermoeconomic method. A furnace for heating air is evaluated using the methodology. The furnace works with solar energy, received from a parabolic trough collector and with electricity supplied by an electric power utility. The methodology evaluates the process by the first and second law of thermodynamics as the first step then the cost analysis is applied for getting the thermoeconomic cost. For this study, the climatic conditions of the city of Queretaro (Mexico are considered. Two periods were taken into account: from July 2006 to June 2007 and on 6 January 2011. The prototype, located at CICATA-IPN, Qro, was analyzed in two different scenarios i.e., with 100% of electricity and 100% of solar energy. The results showed that thermoeconomic costs for the heating process with electricity, inside the chamber, are less than those using solar heating. This may be ascribed to the high cost of the materials, fittings, and manufacturing of the solar equipment. Also, the influence of the mass flow, aperture area, length and diameter of the receiver of the solar prototype is a parameter for increasing the efficiency of the prototype in addition to the price of manufacturing. The optimum design parameters are: length is 3 to 5 m, mass flow rate is 0.03 kg/s, diameter of the receiver is around 10 to 30 mm and aperture area is 3 m2.

  13. A concept of PWR using plate and shell heat exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Freire, Luciano Ondir; Andrade, Delvonei Alves de, E-mail: luciano.ondir@gmail.com, E-mail: delvonei@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    In previous work it was verified the physical possibility of using plate and shell heat exchangers for steam generation in a PWR for merchant ships. This work studies the possibility of using GESMEX commercial of the shelf plate and shell heat exchanger of series XPS. It was found it is feasible for this type of heat exchanger to meet operational and accidental requirements for steam generation in PWR. Additionally, it is proposed an arrangement of such heat exchangers inside the reactor pressure vessel. Such arrangement may avoid ANSI/ANS51.1 nuclear class I requirements on those heat exchangers because they are contained in the reactor coolant pressure barrier and play no role in accidental scenarios. Additionally, those plates work under compression, preventing the risk of rupture. Being considered non-nuclear safety, having a modular architecture and working under compression may turn such architectural choice a must to meet safety objectives with improved economics. (author)

  14. Diseño de un colector solar de placa plana; Design of a solar fl at plate collector

    Directory of Open Access Journals (Sweden)

    Jeovany Rafael Rodríguez Mejía

    2016-02-01

    Full Text Available En el presente artículo se integra el uso de un software de dis eño mecánico y un algoritmo de simulación de la operación de un colector solar de placa plana, con el objeti vo de simplificar el proceso de diseño y manufactura de este último. Se exponen los resultados de la sim ulación de la operación del colector solar considerando diferentes combinaciones en los parámetros de los materiales utilizados, tales como sus propiedades y características físico químicas, además de la var iación de las dimensiones del sistema a diseñar. Finalmente en el artículo se evalúa la operación de un colector solar para las condiciones climatológicas típicas de la irradiancia, velocidad de viento y temperatura ambiente a partir de una serie de curvas sinusoidales, típicas de Cuba, validándose la viabilidad del algoritmo como apoyo en la etapa de diseño y selección de materiales. In this article the use of mechanical design software and an al gorithm for simulating the operation of a flat plate solar collector, with the objective of simplifying the pr ocess of design and manufacture of the latter is integrated. The simulation results of the operation of the sola r collector considering different combinations in the parameters of the materials used, such as its physicochemic al properties and features in addition to the variation of the dimensions of the system design are set. The a rticle finally evaluates the operation of a solar collector for typical climatic conditions of irradiance, wind s peed and ambient temperature from a series of sinusoidal, typical Cuba curves is evaluated, validating the fe asibility of the algorithm as support in step design and material selection.

  15. Yearly average performance of the principal solar collector types

    Energy Technology Data Exchange (ETDEWEB)

    Rabl, A.

    1981-01-01

    The results of hour-by-hour simulations for 26 meteorological stations are used to derive universal correlations for the yearly total energy that can be delivered by the principal solar collector types: flat plate, evacuated tubes, CPC, single- and dual-axis tracking collectors, and central receiver. The correlations are first- and second-order polynomials in yearly average insolation, latitude, and threshold (= heat loss/optical efficiency). With these correlations, the yearly collectible energy can be found by multiplying the coordinates of a single graph by the collector parameters, which reproduces the results of hour-by-hour simulations with an accuracy (rms error) of 2% for flat plates and 2% to 4% for concentrators. This method can be applied to collectors that operate year-around in such a way that no collected energy is discarded, including photovoltaic systems, solar-augmented industrial process heat systems, and solar thermal power systems. The method is also recommended for rating collectors of different type or manufacturer by yearly average performance, evaluating the effects of collector degradation, the benefits of collector cleaning, and the gains from collector improvements (due to enhanced optical efficiency or decreased heat loss per absorber surface). For most of these applications, the method is accurate enough to replace a system simulation.

  16. Development and life cycle analysis of double slope active solar still with flat plate collector

    Directory of Open Access Journals (Sweden)

    A.K. Sethi

    2014-02-01

    Full Text Available Potable water is an essential ingredient of socio-economic development and economic growth. Often water sources are brackish (i.e. contain dissolved salts and/or contain harmful bacteria and therefore cannot be used for drinking. In addition, there are many coastal locations where seawater is abundant but potable water is not available. This study is focused on a development of solar still with flat plat collector for water desalination considered for small scale applications at remote locations where only saline water is available. In this paper the cost of distilled water per kg has been calculated by using the concept of life cycle cost analysis. The pay back periods for different conditions of the distribution of distilled water, namely at the cost it is produced and at the selling price on market rate have been evaluated. The cost of water per kg is minimum Rs. 0.59, when the interest rate and the lifetime of solar still are taken as 4% and 50 years respectively. The lowest payback time 1.23 years is obtained when the selling price of water Rs. 10 per kg.

  17. Selecting the form of plate corrugations of heat exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Pavlenko, V.F.; Nagornyi, V.E.; Dolinskii, V.M.; Kolokolova, T.G.; Chekhov, O.S.

    1987-03-01

    The authors, in the interest of enhancing the thermal efficiency of plate-type heat exchangers, seek to optimize the pattern and size of the corrugations and surface area of these plates as well as their thickness by assessing the corrosion and scale protection afforded by thermoplastic coatings applied to the carbon steels used in the plates. They test the coatings for the effects of pressure, temperature, and various corrosive media, and demonstrate a parametric technique for optimizing pressure and temperature distribution over the corrugated area, for reducing the potential for deformation, and for prolonging plate durability.

  18. Heat transfer in flow past a continuously moving porous flat plate with heat flux

    Digital Repository Service at National Institute of Oceanography (India)

    Murty, T.V.R.; Sarma, Y.V.B.

    The analysis of the heat transfer in flow past a continuously moving semi-infinite plate in the presence of suction/ injection with heat flux has been presented. Similarity solutions have been derived and the resulting equations are integrated...

  19. Financial viability study using a heat pump as an alternative to support solar collector for water heating in Southeastern Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Reis, Roberts Vinicius de Melo; Oliveira, Raphael Nunes; Machado, Luiz; Koury, Ricardo Nassau N. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. of Mechanical Engineering], E-mails: robertsreis@ufmg.br, luizm@demec.ufmg.br, koury@ufmg.br

    2010-07-01

    Along with related greenhouse effect environmental issues, constant problems changes in oil prices,make the use of solar energy an important renewable energy source. Brazil is a country which is privilege, considering the high rates of solar irradiation present throughout most of the entire national territory. Nevertheless, during certain times of the year, a solar energy deficit, leads solar systems to require electrical resistance support. The use of electrical resistance represents 23.5% of electric energy consumption and it presents a low residential energy efficiency. The purpose of this work is conducting a study of Brazilian States in the Southeastern region regarding the financial viability of replacing a resistive system combined with the use of solar collector and a heat pump. One such heat pump has been designed, constructed and tested experimentally. The average performance coefficient is equal to 2.10, a low value due to the use of a hermetic reciprocating compressor. Despite this low-moderate price coefficient of acquisition and installation of a heat pump, a return on investment in from 2.1 to 2.7 years can be expected. Whereas the equipment has a useful life of about 20 years, this period of return on investment is interesting. (author)

  20. Oil Circulation Effects on Evaporation Heat Transfer in Brazed Plate Heat Exchanger using R134A

    OpenAIRE

    Jang, Jaekyoo; Chang, Youngsoo; Kang, Byungha

    2012-01-01

    Experimental study was performed for oil circulation effects on evaporation heat transfer in the brazed type plate heat exchangers using R134A. In this study, distribution device was installed to ensure uniform flow distribution in the refrigerant flow passage, which enhances heat transfer performance of plate type heat exchanger. Tests were conducted for three evaporation temperature; 33℃, 37℃, and 41℃ and several oil circulation conditions. The nominal conditions of refrigerant are as follo...

  1. Enhanced radiative heat transfer between nanostructured gold plates

    CERN Document Server

    Guérout, R; Rosa, F S S; Hugonin, J -P; Dalvit, D A R; Greffet, J -J; Lambrecht, A; Reynaud, S

    2012-01-01

    We compute the radiative heat transfer between nanostructured gold plates in the framework of the scattering theory. We predict an enhancement of the heat transfer as we increase the depth of the corrugations while keeping the distance of closest approach fixed. We interpret this effect in terms of the evolution of plasmonic and guided modes as a function of the grating's geometry.

  2. Solar district heating with evacuated collectors: First year experience of the Knivsta plant

    Science.gov (United States)

    Kjellson, E.; Perers, B.; Zinko, H.; Astrand, L.

    The experience gained during the summer enable some practical demands to be placed on solar collectors, namely: it must be possible to easily replace a solar collector without emptying the system; it must be easy to bleed the system; solar collectors must be able to withstand overheating due to boiling; and obvious leakage risks must be eliminated. There is no doubt that not all types of evacuated solar collectors fulfill these requirements and that further development is essential before large-scale installations with rational operation can be considered.

  3. Comparison of Electrical and Thermal Performances of Glazed and Unglazed PVT Collectors

    Directory of Open Access Journals (Sweden)

    Jin-Hee Kim

    2012-01-01

    Full Text Available Photovoltaic-thermal (PVT collectors combine photovoltaic modules and solar thermal collectors, forming a single device that receives solar radiation and produces electricity and heat simultaneously. PVT collectors can produce more energy per unit surface area than side-by-side PV modules and solar thermal collectors. There are two types of liquid-type flat-plate PVT collectors, depending on the existence of glass cover over PV module: glass-covered (glazed PVT collectors, which produce relatively more thermal energy but have lower electrical yield, and uncovered (unglazed PVT collectors, which have relatively lower thermal energy with somewhat higher electrical performance. In this paper, the experimental performance of two types of liquid-type PVT collectors, glazed and unglazed, was analyzed. The electrical and thermal performances of the PVT collectors were measured in outdoor conditions, and the results were compared. The results show that the thermal efficiency of the glazed PVT collector is higher than that of the unglazed PVT collector, but the unglazed collector had higher electrical efficiency than the glazed collector. The overall energy performance of the collectors was compared by combining the values of the average thermal and electrical efficiency.

  4. Control of Hyperbolic Heat Transfer Mechanisms Application to the Distributed Concentrated Solar Collectors

    KAUST Repository

    Elmetennani, Shahrazed

    2017-04-01

    This dissertation addresses the flow control problem in hyperbolic heat transfer mechanisms. It raises in concentrated distributed solar collectors to enhance their production efficiency under the unpredictable variations of the solar energy and the external disturbances. These factors which are either locally measured (the solar irradiance) or inaccessible for measurement (the collectors’ cleanliness) affect the source term of the distributed model and represent a major difficulty for the control design. Moreover, the temperature in the collector can only be measured at the boundaries. In this dissertation, we propose new adaptive control approaches to provide the adequate level of heat while coping with the unpredictable varying disturbances. First, we design model based control strategies for a better efficiency, in terms of accuracy and response time, with a relatively reduced complexity. Second, we enhance the controllers with on-line adaptation laws to continuously update the efficient value of the external conditions. In this study, we approach the control problem using both, the infinite dimensional model (late lumping) and a finite dimensional approximate representation (early lumping). For the early lumping approach, we introduce a new reduced order bilinear approximate model for system analysis and control design. This approximate state representation is then used to derive a nonlinear state feedback resorting to Lyapunov stability theory. To compensate for the external disturbances and the approximation uncertainties, an adaptive controller is developed based on a phenomenological representation of the system dynamics. For the late lumping approach, we propose two PDE based controllers by stabilization of the reference tracking error distributed profile. The control laws are explicitly defined as functions of the available measurement. The first one is obtained using a direct approach for error stabilization while the second one is derived through a

  5. A one-dimensional heat transfer model for parallel-plate thermoacoustic heat exchangers

    NARCIS (Netherlands)

    de Jong, Anne; Wijnant, Ysbrand H.; de Boer, Andries

    2014-01-01

    A one-dimensional (1D) laminar oscillating flow heat transfer model is derived and applied to parallel-plate thermoacoustic heat exchangers. The model can be used to estimate the heat transfer from the solid wall to the acoustic medium, which is required for the heat input/output of thermoacoustic

  6. Parametric studies of an active solar water heating system with various types of PVT collectors

    Indian Academy of Sciences (India)

    Roonak Daghigh; Mohd Hafidz Ruslan; Kamaruzzaman Sopian

    2015-10-01

    This study simulated active photovoltaic thermal solar collectors (PV/T) for hot water production using TRNSYS. The PV/T collectors consist of the amorphous, monocrystalline and polycrystalline. The long-term performances for the glazed and unglazed PV/T collectors were also evaluated. In this simulation, the design parameters used were collector area of 4 m2, collector slope angle of 15 degree and mass flow rate to the collector area ratio of 8–20 kg/hm2. In addition the tank height between 0.9 m to 1.1 m for unglazed PV/T collectors and 0.9 m to 1 m for glazed collectors, as well as the storage tank volume between 200 and 300 L has been used. The climate parameters used were solar radiation levels range of 4–4.9 kWh/m2, the mean ambient temperature in the range of 25–28°C. The results of the simulation indicated that there was an increase in solar fraction and electrical power output of the active PV/T hot water system.

  7. In - line determination of heat transfer coefficients in a plate heat exchanger

    Science.gov (United States)

    Sotelo, S. Silva; Domínguez, R. J. Romero

    This paper shows an in - line determination of heat transfer coefficients in a plate heat exchanger. Water and aqueous working solution of lithium bromide + ethylene glycol are considered. Heat transfer coefficients are calculated for both fluids. "Type T" thermocouples were used for monitoring the wall temperature in a plate heat exchanger, which is one of the main components in an absorption system. Commercial software Agilent HP Vee Pro 7.5 was used for monitoring the temperatures and for the determination of the heat transfer coefficients. There are not previous works for heat transfer coefficients for the working solution used in this work.

  8. Heat Pipe Embedded AlSiC Plates for High Conductivity - Low CTE Heat Spreaders

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Matthew (DOE/NNSA Kansas City Plant (United States)); Weyant, J.; Garner, S. (Advanced Cooling Technologies, Inc. (Lancaster, PA (United States)); Occhionero, M. (CPS Technologies Corporation, Norton, MA (United States))

    2010-01-07

    Heat pipe embedded aluminum silicon carbide (AlSiC) plates are innovative heat spreaders that provide high thermal conductivity and low coefficient of thermal expansion (CTE). Since heat pipes are two phase devices, they demonstrate effective thermal conductivities ranging between 50,000 and 200,000 W/m-K, depending on the heat pipe length. Installing heat pipes into an AlSiC plate dramatically increases the plate’s effective thermal conductivity. AlSiC plates alone have a thermal conductivity of roughly 200 W/m-K and a CTE ranging from 7-12 ppm/ deg C, similar to that of silicon. An equivalent sized heat pipe embedded AlSiC plate has effective thermal conductivity ranging from 400 to 500 W/m-K and retains the CTE of AlSiC.

  9. Heat and electricity from the Sun using parabolic dish collector systems

    Science.gov (United States)

    Truscello, V. C.; Williams, A. N.

    1980-01-01

    Point focus distributed receiver solar thermal technology for the production of electric power and of industrial process heat is addressed. The thermal power systems project which emphasizes the development of cost effective systems which will accelerate the commercialization and industrialization of plants up to 10 MWe, using parabolic dish collectors is described. The projected size of the isolated load market in the 1990-2000 time period is 300 to 1000 MW/year. Although this market is small in comparison to the grid connected utility market, it is indicated that by assuming only a 20 percent market penetration, up to 10,000 power modules per year would be required to meet this need. At a production rate of 25,000 units/year and assuming no energy storage, levelized bus bar energy costs of 75 mills/kWeh are projected. These numbers are based on what is believed to be a conservative estimate regarding engine-generator conversion efficiency (40 percent) for the 1990 time period. With a more optimistic estimate of efficiency (i.e., 45 percent), the bus bar cost decreases to about 67 mills/kWeh. At very large production rates (400,000 modules/years), the costs decrease to 58 mills/kWeh. Finally, the present status of the technology development effort is discussed.

  10. New terrestrial heat flow measurements on the Nazca Plate

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, R.N. (Columbia Univ., Palisades, NY); Langseth, M.G.; Vacquier, V.; Francheteau, J.

    1976-03-01

    Sixty-seven new heat flow measurements on the Nazca Plate are reported, and the thermal regimes of three specific areas on the plate are examined. The Nazca Ridge is an aseismic ridge which may have been generated as an ''island trail'' from the Easter Island ''hot spot'' and/or may be a fossil transform fault. The Nazca Ridge has lower heat flow than the surrounding sea floor implying that the ridge might have low ''effective'' thermal conductivity causing heat to preferentially flow or refract to surrounding ocean crust which has higher conductivity, or, the low heat flow values may be caused by hydrothermal circulation on the ridge. The Carnegie Plateau is an elevated region south of the Carnegie Ridge on the northeastern Nazca Plate with high heat flow and shallow topography consistent with an age of less than 20 m.y. B.P. The central Nazca Plate is an area of highly variable heat flow which is possibly related to thin sediment and to rough regional topography.

  11. Lateral heat transfer in conducting and mutually irradiating plates

    Energy Technology Data Exchange (ETDEWEB)

    Krishnaprakas, C.K.; Badari Narayana, K. [Thermal Systems Group, ISRO Satellite Centre, Bangalore 560 017 (India)

    2004-05-01

    Lateral heat transfer effect in conducting and mutually irradiating parallel plates has been investigated. The effect of reflection in the diffuse-specular regime has been included. The governing equation of this problem is a complicated integro-differential equation, and this has been solved using the accurate Gauss-Jacobi orthogonal collocation method. The effective thermal conductivity along the lateral direction increases with decreasing conduction-radiation number, increasing emittance of the plates and increasing spacing. Specular reflection effects are insignificant. (orig.)

  12. Experimental studies of a matrix-tubular solar air collector

    Energy Technology Data Exchange (ETDEWEB)

    Plesca, M.; Varlan, P. [Moldova Technical Univ., Chisinau (Moldova, Republic of). Dept. of Heat and Gas Supply and Ventilation

    2009-06-15

    The most common types of solar air collectors (SAC) are contact-type and matrix-type collectors, with the latter being more efficient. This paper described the design and testing of a matrix-tubular flat solar air collector in the city of Chisinau, Moldova, where the outdoor climatic radiation, heat, and humidity characteristics are favorable for the efficient use of solar energy for building heating and drying applications. The amount of solar energy absorbed by a solar energy air collector depends on the level of insulation and orientation of the solar collector; the absorbance of the absorber surface; and the transmittance of the cover material. This study examined the heat transfer, efficiency, and pressure drop using copper tubes inserted perpendicular to the plane of the absorber plate. The SAC consists of a glazed insulated case, an absorber, and ducting for cold air delivery and hot air discharge. Copper tubes are inserted perpendicular to the plane of the absorber. The absorber is installed in the body of the SAC in such a way that it divides it into an upper channel and lower channel. The channel bottom is lined with aluminium foil that reflects solar radiation coming through the tubes and decreases heat loss in the solar collector. Copper tubes increase the heat exchange surface, create air turbulence and intensify heat transfer. This increases the efficiency of the solar collector. The pressure drop of the matrix-tubular solar air collector is 40 per cent lower than that of the matrix-plate collectors. 11 refs., 2 tabs., 6 figs.

  13. Application of sintered plate dust collector in gold mines%烧结板除尘器在黄金矿山的应用

    Institute of Scientific and Technical Information of China (English)

    郑民; 轩慎英; 刘刚

    2016-01-01

    It is always difficult for gold mine to collect dust .Inner Mongolia Pacific Mining Corporation Limited first applies sintered plate dust collectors in the crashing stage during the second phase of expansion project .The sin-tered plate dust collector occupies less space and is reliable with good dust collection effect and lower vent gas concen -tration.The paper based on technical characteristics of dust collection process and performance test results focused on the technical and economical analysis of the application of sintered plate dust collector ,expecting to provide reference of the dust collection process for gold mines .%黄金生产中的除尘问题一直受到黄金矿山企业的关注.内蒙古太平矿业有限公司二期扩建项目首次在选矿厂破碎工段采用了烧结板除尘器,其设备占地面积小、运行可靠、除尘效果好、尾气质量浓度低于排放标准.该文结合除尘工艺技术特点以及设备性能测试结果,重点对烧结板除尘器的应用进行了技术与经济分析,以期为类似黄金矿山企业除尘工艺提供参考.

  14. Numerical Investigation of Nanofluid-based Solar Collectors

    Science.gov (United States)

    Karami, M.; Raisee, M.; Delfani, S.

    2014-08-01

    Solar thermal collectors are applicable in the water heating or space conditioning systems. Due to the low efficiency of the conventional collectors, some suggestions have been presented for improvement in the collector efficiency. Adding nanoparticles to the working fluid in direct absorption solar collector, which has been recently proposed, leads to improvement in the working fluid thermal and optical properties such as thermal conductivity and absorption coefficient. This results certainly in collector efficiency enhancement. In this paper, the radiative transfer and energy equations are numerically solved. Due to laminar and fully developed flow in the collector, the velocity profile is assumed to be parabolic. As can be observed from the results, outlet temperature of collector is lower than that obtained using uniform velocity profile. Furthermore, a suspension of carbon nanohorns in the water is used as the working fluid in the model and its effect on the collector efficiency is investigated. It was found that the presence of carbon nanohorns increases the collector efficiency by about 17% compared to a conventional flat-plate collector. In comparison with the mixture of water and aluminium nanoparticles, a quite similar efficiency is obtained using very lower concentration of carbon nanohorns in the water.

  15. Air/liquid collectors

    DEFF Research Database (Denmark)

    Jensen, Søren Østergaard; Olesen, Ole; Kristiansen, Finn Harken

    1997-01-01

    This report determine efficiency equations for combined air/liquid solar collectors by measurements on to different air/liquid collectors. Equations which contain all relevant informations on the solar collectors. A simulation program (Kviksol) has been modified in order to be able to handle...... this kind of collectors. The modified simulation program has been used for the determination of the surplus in performance which solar heating systems with this type of solar collectors for combined preheating of ventilation air and domestic hot water will have. The simulation program and the efficiency...

  16. A simplified model of heat transfer in heat exchangers and stack plates of thermoacoustic refrigerators

    Science.gov (United States)

    Herman, Cila; Chen, Yuwen

    2006-08-01

    A simplified model of heat transfer was developed to investigate the thermal behavior of heat exchangers and stack plates of thermoacoustic devices. The model took advantage of previous results describing the thermal behavior of the thermoacoustic core and heat transfer in oscillating flow to study the performance of heat exchangers attached to the core. The configuration considered is a flat tube (with a working fluid flowing in the tube) of the thickness of the stack plate attached to both ends of the stack plate. Geometrical and operational parameters as well as thermophysical properties of the heat exchangers, transport fluids in the heat exchangers, stack plate and the thermoacoustic working fluid were organized into dimensionless groups that allowed accounting for their impact on the performance of the heat exchangers. Two types of thermal boundary conditions were considered: constant temperature and constant heat flux along the heat exchanger tubes. Numerical simulations were carried out with the model introduced in the paper. The temperature distributions and heat fluxes near the edge of the stack plate were found to be nonlinear. The influence of system parameters on the thermal performance of the heat exchangers was analyzed.

  17. Thermal performance evaluation of Solar Energy Products Company (SEPCO) 'Soloron' collector tested outdoors

    Science.gov (United States)

    Chiou, J., Sr.

    1977-01-01

    The test article, Model EF-212, Serial Nr. 002, is a single glazed collector with a nonselective absorber plate, using flowing air as the heat transfer medium. The absorber plate and box frame are aluminum and the insulation is one inch isocyanurate foam board with thermal conductivity of 0.11 (BTU/sq ft Hr0/ft.) The tests included the following. (1) time constant test, (2) collector efficiency test, (3) collector stagnation test, (4) incident angle modifier test, (5) load test, (6) weathering test, and (7) absorber plate optical properties test. The results of these tests are tabulated, graphed, or otherwise recorded.

  18. Indoor test for thermal performance evaluation of Sunworks (liquid) solar collector

    Science.gov (United States)

    Shih, K.

    1977-01-01

    Test procedures used and test results obtained from an evaluation test program conducted on a single covered liquid solar collector under simulated conditions are presented. The test article was a flat plate solar collector using water as the heat transfer medium. The absorber plate was copper with copper tubes bonded by soft solder. The plate was coated with Enthone selective black with an absorptivity factor of .87 approximately .92 and an emissivity factor of .10 approximately .20. A time constant test and incident angle modifier test were conducted to determine the transient effect and the incident angle effect on the collector.

  19. Decosol Project : development of solar plate collectors of high efficiency and low cost for medium temperature application; Proyecto Decosol: Desarrollo de colectores solares planos de alta eficiencia ybajo coste para aplicaciones a mediana temperatura

    Energy Technology Data Exchange (ETDEWEB)

    Cadafalch, J.; Oliva, A.; Lavandeira, J. C.; Maestre, F.; Martinez, J. C.; Martin, J. R.; Hermo, R.

    2004-07-01

    Work that is currently being carried out by the authors in the framework of the project DECOSOL (Development of high efficiency and low cost flat plate collectors for medium temperature applications) is described in this paper. The goal of DECOSOL is to consolidate the results of previous R AND D projects conducted by the authors on the development of stagnation proof transparently insulated flat plate solar collectors prototypes, in order to end up with commercial products. (Author)

  20. Experimental validation of dynamic simulation of the flat plate collector in a closed thermosyphon solar water heater

    DEFF Research Database (Denmark)

    Taherian, H.; Kolaei, Alireza Rezania; Sadeghi, S.;

    2011-01-01

    This work studies the dynamic simulation of thermosyphon solar water heater collector considering the weather conditions of a city in north of Iran. The simulation was done for clear and partly cloudy days. The useful energy, the efficiency diagrams, the inlet and the outlet of collector, center...

  1. Investigation of effect of oblique ridges on heat transfer in plate heat exchangers

    Science.gov (United States)

    Novosád, Jan; Dvořák, Václav

    2014-03-01

    This article deals with numerical investigation of flow in plate heat exchangers. These are counterflow heat exchangers formed by plates. These plates are shaped by the ridges to intensify heat transfer. The objective of the work is the investigation of effect of straight oblique triangular ridges for increasing of heat transfer and pressure losses. The ridges on adjacent plates intersect and thus form a channel of complex shape. The research includes various types of ridges with different fillets and ridges spacing.The work also investigates the number of ridges that is necessary for optimization calculations. Obtained data are analysed and the heat transfer coefficient and pressure loss are evaluated. Conclusion describes the effect of fillets, ridges pitch and number of ridges.

  2. Performance Simulation of Microchannel Collector/Evaporator for Solar Heat Pump Water Heater%太阳能热泵热水系统微细通道集热板/蒸发器性能模拟

    Institute of Scientific and Technical Information of China (English)

    周伟; 张小松

    2016-01-01

    本文提出了一种采用微细通道的平板式集热板/蒸发器,它可以从太阳和环境空气二方面获取热量。其主要特点是采用树形分支模型,由两块铝板冷轧吹胀而成,减小了接触热阻,提高了集热板的换热系数。本文建立了该集热板/蒸发器的数学模型并进行了热性能分析,深入研究了不同环境工况条件下该热泵热水系统的性能,包括系统性能系数(COP)、集热板集热效率、加热时间等运行参数的变化特性。结果显示,将150 L水从15 oC加热到50 oC时,系统全年各月的平均COP为4.76,平均加热时间为314 min,环境温度的升高和太阳辐射强度的降低会使集热效率显著增加。%In this paper a new flat-plate collector/evaporator was presented by using microchannel to gain heat from both solar radiation and ambient air. Its main characteristic was using the model of tree branch. The collector/evaporator was made of two pieces of aluminium plates by using the method of cold-rolled huff, which could reduce the contact thermal resistance and improve the heat transfer efficiency of the collector. A simulation model of the collector/evaporator was developed and its thermal performance was analyzed. The performances of heat pump hot water system were evaluated experimentally under different ambients, including heat pump coefficient of performance (COP), heat collecting efficiency and heating time of hot water, etc. The results showed that heating 150 L water with the heat pump from 15 oC to 50 oC, the COP of the whole year was 4.76, and the heating time was 314 min all year around. Meanwhile the heat collecting efficiency increased evidently with the ambient temperature increasing and solar radiation intensity decreasing.

  3. Watergy. A moist air solar collector system with an integrated brine circuit for te heating of buildings; Watergy. Ein Feuchtluft-Solarkollektorsystem mit integriertem Solekreislauf zur Gebaeudeheizung

    Energy Technology Data Exchange (ETDEWEB)

    Buchholz, Martin; Buchholz, Reiner; Geyer, Philipp; Schmidt, Marco [Technische Univ. Berlin (Germany). Fachgebiet Gebaeudetechnik und Entwerfen

    2010-07-01

    Due to the Renewable Energy Law 2009, the proportion of renewable energies in the overall energy consumption of the European Union increased to 20 %. Currently, the proportion of the total heat energy consumption in Germany amounts nearly 40 %. Previous concepts for the storage of heat in the summer for use in winter are not convincing. The improvement of the efficiency of solar collectors and an increase in the collector surface result in increased investment costs and costs for heat supply. Thus, solar collector systems should be optimized for the operation of heaters. This is done for example by reducing the mean collector temperature using a combination of solar collectors with a heat pump. However, heat pumps are operated by means of electrical energy. Electrical energy can not be saved in the summer in order to be used in the winter. Under this aspect, the authors of the contribution under consideration report on the Watergy concept - a moist air solar collector system with an integrated brine circuit for heating of buildings.

  4. Solar collector studies for solar heating and cooling applications. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, J. H.; Jensen, S. O.; Kovacic, J. E.

    1980-01-01

    A summary of the literature, especially patent teachings pertaining to black fluid solar collectors is given. Laboratory tests to determine the suspension stability of various carbon types in water/Propylene glycol are reported. The suspensions were aged at 160/sup 0/F for 3600 hours and at -15/sup 0/F for 1100 hours. It is suggested that the suspending agent interacts with electrical charges on the carbon particles to prevent agglomeration. The liquid was tested for its operating characteristics with several collector design variables using glass tubes as the containment system. The collectors were installed in a house previously operated on a black liquid system, and observed for a six month period with the weather ranging from -12/sup 0/F to 94/sup 0/F with no major problems occurring with either the liquid or the collectors.

  5. ANALYSIS AND MODELING OF SOLAR EVAPORATOR-COLLECTOR

    Directory of Open Access Journals (Sweden)

    Zakaria Mohd. Amin

    2015-11-01

    Full Text Available Solar energy is considered a sustainable resource that poses little to no harmful effects on the environment. The performance of a solar system depends to a great extent on the collector used for the conversion of solar radiant energy to thermal energy. A solar evaporator-collector (SEC is basically an unglazed flat plate collector where refrigerants, such as R134a is used as the working fluid. As the operating temperature of the SEC is very low, it utilizes both solar irradiation and ambient energy leading to a much higher efficiency than the conventional collectors. This capability of SECs to utilize ambient energy also enables the system to operate at night. This type of collector can be locally made and is relatively much cheaper than the conventional collector.   At the National University of Singapore, the evaporator-collector was integrated to a heat pump and the performance was investigated for several thermal applications: (i water heating, (ii drying and (iii desalination. A 2-dimensional transient mathematical model of this system was developed and validated by experimental data. The present study provides a comprehensive study of performance. KEYWORDS: heat pump; evaporator-collector.

  6. EXPERIMENTAL RESEARCH ON A HIGH EFFICIENT FLAT PLATE SOLAR COLLECTOR%一种高效平板太阳能集热器试验研究

    Institute of Scientific and Technical Information of China (English)

    李戬洪; 江晴

    2001-01-01

    性能良好的太阳能集热器是太阳能空调的关键设备之一。广东省江门市太阳能空调系统采用了一种高效的平板集热器,其主要技术特征是增加了一块聚碳酸脂(PC)透明隔热板。本研究通过对比试验,确定了一种高效平板太阳能集热器的技术方案,并测定了瞬时效率曲线,其热损系数仅为2.90W/(m2*℃)。%Good performance of the solar collectors is one of the important elements for solar air-conditioning system.A novel type of high efficient flat plate solar collector was applied to the solar air-condition system in Jiangmen,Guangdong Province.Tests show that adding a transparent polycarbonate sheet in gap between glazing and absorber of the collector. The coefficient of the thermal loss is reduced to 2.90W/(m2℃) and the performance of the collector is improved.

  7. Brazed aluminum, Plate-fin heat exchangers for OTEC

    Energy Technology Data Exchange (ETDEWEB)

    Foust, H.D.

    1980-12-01

    Brazed aluminum plate-fin heat exchangers have been available for special applications for over thirty years. The performance, compactness, versatility, and low cost of these heat exchangers has been unequaled by other heat exchanger configuration. The application of brazed aluminum has been highly limited because of necessary restrictions for clean non-corrosive atmospheres. Air and gas separation have provided ideal conditions for accepting brazed aluminum and in turn have benefited by the salient features of these plate-fin heat exchangers. In fact, brazed aluminum and cryogenic gas and air separation have become nearly synonymous. Brazed aluminum in its historic form could not be considered for a seawater atmosphere. However, technology presents a new look of significant importance to OTEC in terms of compactness and cost. The significant technological variation made was to include one-piece hollow extensions for the seawater passages. Crevice corrosion sites are thereby entirely eliminated and pitting corrosion attack will be controlled by an integral and sacrificial layer of a zinc-aluminum alloy. This paper on brazed aluminum plate-fin heat exchangers for OTEC will aquaint the reader with the state-of-art and variations suggested to qualify this form of aluminum for seawater use. In order to verify the desirable cost potential for OTEC, Trane teamed with Westinghouse to perform an OTEC system analysis with this heat exchanger. These results are very promising and reported in detail elsewhere.

  8. Linear concentrating collector as an air heater in the heating system of building in Polish climatic conditions

    Directory of Open Access Journals (Sweden)

    Nemś Magdalena

    2016-01-01

    Full Text Available The article presents the analysis of the performance of a concentrating collector in the heating system of a residential building. Air was used as the working fluid. The heating requirements of the building were determined for each day of the year. The amount of direct irradiation reaching the absorber’s surface on all the days of the year was determined with the use of hourly meteorological data for Wroclaw, shared by the Ministry of Infrastructure and Growth. It was assumed that the collector is equipped with a tracking system working in one axis. Calculations and comparisons were made for the amount of solar irradiation for three values of the receiver’s inclination angle: β1=60°, β2=90° and β3=30°. Statistical method was used in order to determine the optimum inclination of the mirror and the amount of flowing air. This method involves creating a plan of experiment with three levels of changeability for two input factors. In the last stage, the amount of heat obtained from the installation during all the days of the year was analysed. The gains were juxtaposed on the diagram with the building’s heat demand. The analysis has shown that the heat requirements can be met only partially.

  9. Heat transport in the Hadean mantle: From heat pipes to plates

    Science.gov (United States)

    Kankanamge, Duminda G. J.; Moore, William B.

    2016-04-01

    Plate tectonics is a unique feature of Earth, and it plays a dominant role in transporting Earth's internally generated heat. It also governs the nature, shape, and the motion of the surface of Earth. The initiation of plate tectonics on Earth has been difficult to establish observationally, and modeling of the plate breaking process has not consistently accounted for the nature of the preplate tectonic Earth. We have performed numerical simulations of heat transport in the preplate tectonic Earth to understand the transition to plate tectonic behavior. This period of time is dominated by volcanic heat transport called the heat pipe mode of planetary cooling. These simulations of Earth's mantle include heat transport by melting and melt segregation (volcanism), Newtonian temperature-dependent viscosity, and internal heating. We show that when heat pipes are active, the lithosphere thickens and lithospheric isotherms are kept flat by the solidus. Both of these effects act to suppress plate tectonics. As volcanism wanes, conduction begins to control lithospheric thickness, and large slopes arise at the base of the lithosphere. This produces large lithospheric stress and focuses it on the thinner regions of the lithosphere resulting in plate breaking events.

  10. Analysis of slip flow heat transfer between two unsymmetrically heated parallel plates with viscous dissipation

    Indian Academy of Sciences (India)

    HARI MOHAN KUSHWAHA; SANTOSH K SAHU

    2016-06-01

    This paper presents an analytical investigation to study the heat transfer and fluid flow characteristics in the slip flow region for hydrodynamically and thermally fully developed flow between parallel plates.Both upper and lower plates are subjected to asymmetric heat flux boundary conditions. The effect of first ordervelocity slip, temperature jump, asymmetric heat flux ratio and viscous dissipation on the heat transfer performance is analyzed. Closed form expressions are obtained for the temperature distribution and Nusselt number. Present predictions are verified for the cases that neglect the viscous heating and microscale effects. The effect of asymmetric heat flux ratio with and without viscous dissipation on Nusselt number for both macroscale and microscale is highlighted. The heat transfer characteristics are found to depend on various modeling parameters, namely, modified Brinkman number, Knudsen number and heat flux ratio

  11. Connectable solar air collectors

    Energy Technology Data Exchange (ETDEWEB)

    Oestergaard Jensen, S.; Bosanac, M.

    2002-02-01

    The project has proved that it is possible to manufacture solar air collector panels, which in an easy way can be connected into large collector arrays with integrated ducting without loss of efficiency. The developed connectable solar air collectors are based on the use of matrix absorbers in the form of perforated metal sheets. Three interconnected solar air collectors of the above type - each with an transparent area of approx. 3 m{sup 2} - was tested and compared with parallel tests on two single solar air collectors also with a transparent area of approx. 3 m{sup 2} One of the single solar air collectors has an identical absorber as the connectable solar air collectors while the absorber of the other single solar air collector was a fibre cloth. The efficiency of the three solar air collectors proved to be almost identical in the investigated range of mass flow rates and temperature differences. The solar air collectors further proved to be very efficient - as efficient as the second most efficient solar air collectors tested in the IEA task 19 project Solar Air Systems. Some problems remain although to be solved: the pressure drop across especially the connectable solar air collectors is too high - mainly across the inlets of the solar air collectors. It should, however, be possible to considerably reduce the pressure losses with a more aerodynamic design of the inlet and outlet of the solar air collectors; The connectable solar air collectors are easy connectable but the air tightness of the connections in the present form is not good enough. As leakage leads to lower efficiencies focus should be put on making the connections more air tight without loosing the easiness in connecting the solar air collectors. As a spin off of the project a simple and easy way to determine the efficiency of solar, air collectors for pre-heating of fresh air has been validated. The simple method of determining the efficiency has with success been compared with an advance method

  12. Vibrations and instabilities of thin rectangular plates separated by fluid medium with applications to the plate type heat exchanger

    Energy Technology Data Exchange (ETDEWEB)

    Gi-Man, Kim [Kum-Oh National Univ., Taegu (Korea, Republic of)

    1994-12-31

    Due to the prohibition law for using preon gas, many items in engineering field, specially heat exchanger, should be redesigned. The newly designed heat exchanger such a plate type heat exchanger is known to have a good efficiency in exchanging heat. From view of structures of a plate type heat exchanger, thin tube are used instead of circular pipe and the path of the fluid is developed for the high efficiency of the heat exchange by varying the array of tubes. The principal problem in the design of the plate heat exchanger is the potentiality of structural instabilities due to the fluid loading effect during operations. Excessive plate deflections would eventually result in permanent deformation or collapse which would cause an obstruction of the fluid flow in the narrow channels. In this study, a fluid-structural interaction model was developed to investigate analytically the static and dynamic instabilities that have been observed in flat plate heat exchanger. The model consist of two flat plates separated by water. The effects of the internal fluid in the channel was studied. As results, the natural frequency coefficients were investigated for the plate aspect ratios, channel heights, and boundary conditions. For the design criteria in plate type heat exchanger, the critical flow velocities which cause the responses of a plate were defined for divergence, resonance and flutter phenomena. (author). 25 refs. 2 tabs. 48 figs.

  13. Closed loop oscillating heat pipe as heating device for copper plate

    Science.gov (United States)

    Kamonpet, Patrapon; Sangpen, Waranphop

    2017-04-01

    In manufacturing parts by molding method, temperature uniformity of the mold holds a very crucial aspect for the quality of the parts. Studies have been carried out in searching for effective method in controlling the mold temperature. Using of heat pipe is one of the many effective ways to control the temperature of the molding area to the right uniform level. Recently, there has been the development of oscillating heat pipe and its application is very promising. The semi-empirical correlation for closed-loop oscillating heat pipe (CLOHP) with the STD of ±30% was used in design of CLOHP in this study. By placing CLOHP in the copper plate at some distance from the plate surface and allow CLOHP to heat the plate up to the set surface temperature, the temperature of the plate was recorded. It is found that CLOHP can be effectively used as a heat source to transfer heat to copper plate with excellent temperature distribution. The STDs of heat rate of all experiments are well in the range of ±30% of the correlation used.

  14. Numerical evaluation of plate heat exchanger performance in geothermal district heating systems

    Energy Technology Data Exchange (ETDEWEB)

    Karlsson, T. [Iceland Univ., Reykjavik (Iceland)

    1996-12-31

    This paper describes the performance of plate heat exchangers in residential water radiator heating systems receiving their heat from geothermal resources. Radiator theory is reviewed and determination of annual hot water requirements for space heating is discussed. Performance evaluation is made of plate heat exchangers and results obtained by means of two equations commonly used for this purpose, the Sieder-Tate and the Dittus-Boelter equations, compared to results obtained with a simplified equation where heat transfer in the heat exchanger is assumed to depend only on the fluid mass flow on both sides. It is found that for prevailing temperature ranges in Icelandic geothermal systems the mass pow approximation gives results very close to those determined by the more complicated conventional equations. (UK)

  15. 平板式太阳能空气集热器流道改进的试验研究和数值模拟%Experimental investigation and numerical simulation on improvement of flat-plate solar air collector flow channels

    Institute of Scientific and Technical Information of China (English)

    丁刚; 左然; 张旭鹏; 王坤

    2011-01-01

    对传统平板式太阳能空气集热器的流道进行了改进,把对角型进出口流道改为多进出口式流道.对改进的集热器的性能进行了试验测试.新的进出口流道消除了吸热板和空气换热不均的现象,出口温度提升明显.在相同条件下,集热器的瞬时效率增加约20%.用CFD方法对集热器内部的流场结构和传热进行的数值模拟对比表明,传统集热器内部存在流动死区,中心截面温度分布不均匀,吸热板上有局部的高温区域,改进后的集热器流场和温度场分布得较均匀.%The flow channels of traditional flat-plate solar air collector were changed from diagonal inlet/outlet to multi-inlet/outlet. Experimental investigation on characteristics of solar air collectors after the improvement of flow channels was reported. The inlet and outlet channels of the conventional air collector were improved. The new flow channel eliminates the ununiformity of heat transfer between air and absorber plate, so there is a distinct temperature increasing at the outlet. The instantaneous efficiency is improved by about 20% at the same condition. An analysis of flow characteristics and heat transfer in the collectors had been carried out by using Computation Fluid Dynamic (CFD). There is the dead zone in flow field of traditional collector. The temperature distribution of center section is different and there is local high-temperature region on the heat-absorbing plate in the traditional collector, while the flow field and temperature distribution are uniform in the improved collector.

  16. Thermal performance of integration of solar collectors and building envelopes

    Institute of Scientific and Technical Information of China (English)

    于国清; 龚小辉; 曹双华

    2009-01-01

    The integration of building with solar collector was studied. The theoretical model of integration of building envelopes and flat plate solar collectors was set up and the thermal performance of integration was studied in winter and summer,and compared to envelopes without solar collectors. The results show that the solar collection efficiency is raised in the integration of building envelopes and solar collectors with the air layer doors closed. This is true whether in winter or summer. The increment is higher as the inlet water temperature increases or the ambient temperature is low. In winter,the heat loss is significantly reduced through integration of the building envelopes and solar collectors with the closed air layer doors. The integration with the open air layer door is worse than that without collectors. In summer,the heat gains of the integration of envelopes and solar collectors are more obviously reduced than envelopes without collectors,the integration with the open air layer door is a little better than the closed one,but the difference is very small.

  17. Boiling heat transfer of refrigerant R-21 in upward flow in plate-fin heat exchanger

    Science.gov (United States)

    Kuznetsov, V. V.; Shamirzaev, A. S.

    2015-11-01

    The article presents the results of experimental investigation of boiling heat transfer of refrigerant R-21 in upward flow in a vertical plate-fin heat exchanger with transverse size of the channels that is smaller than the capillary constant. The heat transfer coefficients obtained in ranges of small mass velocities and low heat fluxes, which are typical of the industry, have been poorly studied yet. The characteristic patterns of the upward liquid-vapor flow in the heat exchanger channels and the regions of their existence are detected. The obtained data show a weak dependence of heat transfer coefficient on equilibrium vapor quality, mass flow rate, and heat flux density and do not correspond to calculations by the known heat transfer models. A possible reason for this behavior is a decisive influence of evaporation of thin liquid films on the heat transfer at low heat flux.

  18. Design of Shell Plates Minimizing the Heat Input

    DEFF Research Database (Denmark)

    Randrup, Thomas; Basu, Nemai

    1998-01-01

    It is the purpose of this paper to present a current research project at Odense Steel Shipyard Ltd., Denmark. The objective of the research is to find new mathematical methods for the design of shell plates and apply these methods at the shipyard. The focus is on double-curved plates...... image of a given surface, we determine a projection plane. In the orthogonal projection of the surface onto this plane, a reference curve is determined by use of methods for thinning of binary images. The cylinder surface then can be derived with its directrix in the projected area and rulings...... perpendicular to the projection plane.Application of the results will be used to analyse the plate layout for production and suggest better alternatives, and thereby minimize the heat input....

  19. DETERMINATION OF HEAT LOSS FACTOR OF SOLAR ENERGY COLLECTOR WITH THE ABSORBER MADE FROM POLYMERIC PIPES

    Directory of Open Access Journals (Sweden)

    Ermuratskii V.

    2009-12-01

    Full Text Available It is studied thermal loss factor of solar energy collector, which absorber represents the register made from polymeric pipes. Input data are results of tests in non-stationary thermal regime at the zero water flow rate and the minimum sunlight.

  20. A facile route for controlled alignment of carbon nanotube-reinforced, electrospun nanofibers using slotted collector plates

    Directory of Open Access Journals (Sweden)

    G. R. Rakesh

    2015-02-01

    Full Text Available A facile route for controlled alignment of electrospun multiwalled carbon nanotube (MWCNT-reinforced Polyvinyl Alcohol (PVA nanofibers using slotted collector geometries has been realized. The process is based on analytical predictions using electrostatic field analysis for envisaging the extent of alignment of the electrospun fibers on varied collector geometries. Both the experimental and theoretical studies clearly indicate that the introduction of an insulating region into a conductive collector significantly influences the electrostatic forces acting on a charged fiber. Among various collector geometries, rectangular slotted collectors with circular ends showed good fiber alignment over a large collecting area. The electrospun fibers produced by this process were characterized by Atomic Force Microscopy (AFM, High Resolution Transmission Electron Microscopy (HRTEM, Scanning Electron Microscopy (SEM and Optical Microscopy. Effects of electrospinning time and slot widths on the fiber alignment have been analyzed. PVA-MWCNT nanofibers were found to be conducting in nature owing to the presence of reinforced MWCNTs in PVA matrix. The method can enable the direct integration of aligned nanofibers with controllable configurations, and significantly simplify the production of nanofibersbased devices.

  1. Effect of Corrugation Angle on Heat Transfer Studies of Viscous Fluids in Corrugated Plate Heat Exchangers

    Directory of Open Access Journals (Sweden)

    B Sreedhara Rao

    2015-04-01

    Full Text Available In the present investigation heat transfer studies are conducted in corrugated plate heat exchangers (PHEs having three different corrugation angles of 300, 400 and 500. The plate heat exchangers have a length of 30 cm and a width of 10 cm with a spacing of 5 mm. Water and 20% glycerol solution are taken as test fluids and hot fluid is considered as heating medium. The wall temperatures are measured along the length of exchanger at seven different locations by means of thermocouples. The inlet and outlet temperatures of test fluid and hot fluid are measured by means of four more thermocouples. The experiments are conducted at a flowrate ranging from 0.5 lpm to 6 lpm with the test fluid. Film heat transfer coefficient and Nusselt number are determined from the experimental data. These values are compared with different corrugation angles. The effects of corrugation angles on heat transfer rates are discussed.

  2. Forced Convective Heat Transfer in a Porous Plate Channel

    Institute of Scientific and Technical Information of China (English)

    PeixueJiang; ZhanWang; 等

    1997-01-01

    Fored convective heat transfer in a plate channel filled with metallic spherical particales was investigated experimentally and numerically.The test section ,58mm×80mm×50mm in size,was heated by a 0.4mm thick plate electrical heater,The coolant water flow rate ranged from 0.015 to 0.833 kg/s.The local wall temperature distribution was measured along with the inlet and outlet fliud temperatures and pressures.The results illustrate the heat transfer augmentation and increased pressure drop caused by the porous medium.The heat transfer coefficient was increased 5-12 times by the porous media although the hydraulic resistance was increased even more.The Nusselt number and the heat transfer coefficient increased with decreasing particle diameter,while the pressure drop decreased as the particle diameter increased.It was found that,for the conditions studied(metallic packed bed),the effect of thermal dispersion did not need to be considered in the physical model,as opposed to a non-metallic packed bed,where thermal dispersion is important.

  3. The effect and contribution of wind generated rotation on outlet temperature and heat gain of LS-2 parabolic trough solar collector

    Directory of Open Access Journals (Sweden)

    Sadaghiyani Omid Karimi

    2013-01-01

    Full Text Available The Monte Carlo ray tracing method is applied and coupled with finite volume numerical methods to study effect of rotation on outlet temperature and heat gain of LS-2 parabolic trough concentrator (PTC. Based on effect of sunshape, curve of mirror and use of MCRT, heat flux distribution around of inner wall of evacuated tube is calculated. After calculation of heat flux, the geometry of LS-2 Luz collector is created and finite volume method is applied to simulate. The obtained results are compared with Dudley et al test results for irrotational cases to validate these numerical solving models. Consider that, for rotational models ,the solving method separately with K.S. Ball's results. In this work, according to the structure of mentioned collector, we use plug as a flow restriction. In the rotational case studies, the inner wall rotates with different angular speeds. We compare results of rotational collector with irrotational. Also for these two main states, the location of plug changed then outlet temperature and heat gain of collector are studied. The results show that rotation have positive role on heat transfer processing and the rotational plug in bottom half of tube have better effectual than upper half of tube. Also the contribution of rotation is calculated in the all of case studies. Working fluid of these study is one of the oil derivatives namely Syltherm-800. The power of wind can be used to rotate tube of collector.

  4. 空气-水复合平板型太阳能集热器%Experiment test of hybrid air-water solar flat plate collector

    Institute of Scientific and Technical Information of China (English)

    赵东亮; 代彦军; 李勇

    2011-01-01

    This paper focuses on a new type of solar collector that has the potential for using in solar heating systems. It can use both air and water as the circulation mediums. Experiment results show that the collector efficiency is between 55%~65% when air is used as the circulation medium, while the efficiency is between 32%~34% for using water as the circulation medium, and it can meet the requirement of solar heating systems. Moreover, this collector is fairly cheap, therefore, especially suitable for the rural areas in north China.%提出了一种适用于太阳能供热采暖工程的新型太阳能空气-水复合平板集热器.该集热器可以单独使用空气、水或同时以空气和水作为集热工质.测试显示,该集热器空气循环集热效率为55%~65%,水循环集热效率为32%~34%,能够满足太阳能供热采暖工程的要求.该集热器成本不高,适用于在我国北方广大农村地区推广使用.

  5. Indoor test for thermal performance evaluation of Lenox-Honeywell solar collector. [conducted using Marshall Space Flight Center Solar Simulator

    Science.gov (United States)

    Shih, K.

    1977-01-01

    The test procedures used and the test results obtained from an evaluation test program conducted on a double-covered liquid solar collector under simulated conditions are presented. The test article was a flat plate solar collector using liquid as the heat transfer medium. The absorber plate was steel with the copper tubes bonded on the upper surface. The plate was coated with black chrome with an absorptivity factor of .95 and emissivity factor of .12. A time constant test and incident angle modifier test were conducted to determine the transient effect and the incident angle effect on the collector.

  6. A one-dimensional heat transfer model for parallel-plate thermoacoustic heat exchangers.

    Science.gov (United States)

    de Jong, J A; Wijnant, Y H; de Boer, A

    2014-03-01

    A one-dimensional (1D) laminar oscillating flow heat transfer model is derived and applied to parallel-plate thermoacoustic heat exchangers. The model can be used to estimate the heat transfer from the solid wall to the acoustic medium, which is required for the heat input/output of thermoacoustic systems. The model is implementable in existing (quasi-)1D thermoacoustic codes, such as DeltaEC. Examples of generated results show good agreement with literature results. The model allows for arbitrary wave phasing; however, it is shown that the wave phasing does not significantly influence the heat transfer.

  7. Numerical and Experimental Study on Energy Performance of Photovoltaic-Heat Pipe Solar Collector in Northern China

    Directory of Open Access Journals (Sweden)

    Hongbing Chen

    2015-01-01

    Full Text Available Several studies have found that the decrease of photovoltaic (PV cell temperature would increase the solar-to-electricity conversion efficiency. Water type PV/thermal (PV/T system was a good choice but it could become freezing in cold areas of Northern China. This paper proposed a simple combination of common-used PV panel and heat pipe, called PV-heat pipe (PV-HP solar collector, for both electrical and thermal energy generation. A simplified one-dimensional steady state model was developed to study the electrical and thermal performance of the PV-HP solar collector under different solar radiations, water flow rates, and water temperatures at the inlet of manifold. A testing rig was conducted to verify the model and the testing data matched very well with the simulation values. The results indicated that the thermal efficiency could be minus in the afternoon. The thermal and electrical efficiencies decreased linearly as the inlet water temperature and water flow rate increased. The thermal efficiency increased while the electrical efficiency decreased linearly as the solar radiation increased.

  8. Inverse heat transfer problem in digital temperature control in plate fin and tube heat exchangers

    Science.gov (United States)

    Taler, Dawid; Sury, Adam

    2011-12-01

    The aim of the paper is a steady-state inverse heat transfer problem for plate-fin and tube heat exchangers. The objective of the process control is to adjust the number of fan revolutions per minute so that the water temperature at the heat exchanger outlet is equal to a preset value. Two control techniques were developed. The first is based on the presented mathematical model of the heat exchanger while the second is a digital proportional-integral-derivative (PID) control. The first procedure is very stable. The digital PID controller becomes unstable if the water volumetric flow rate changes significantly. The developed techniques were implemented in digital control system of the water exit temperature in a plate fin and tube heat exchanger. The measured exit temperature of the water was very close to the set value of the temperature if the first method was used. The experiments showed that the PID controller works also well but becomes frequently unstable.

  9. Heat transfer in plate heat exchanger channels: Experimental validation of selected correlation equations

    Directory of Open Access Journals (Sweden)

    Cieśliński Janusz T.

    2016-09-01

    Full Text Available This study is focused on experimental investigation of selected type of brazed plate heat exchanger (PHEx. The Wilson plot approach was applied in order to estimate heat transfer coefficients for the PHEx passages. The main aim of the paper was to experimentally check ability of several correlations published in the literature to predict heat transfer coefficients by comparison experimentally obtained data with appropriate predictions. The results obtained revealed that Hausen and Dittus-Boelter correlations underestimated heat transfer coefficient for the tested PHEx by an order of magnitude. The Aspen Plate code overestimated heat transfer coefficient by about 50%, while Muley-Manglik correlation overestimated it from 1% to 25%, dependent on the value of Reynolds number and hot or cold liquid side.

  10. Assessment of Real Heat Transfer Coefficients through Shell and Tube and Plate Heat Exchangers

    Directory of Open Access Journals (Sweden)

    Dan CONSTANTINESCU

    2011-07-01

    Full Text Available The purpose of this paper is to present a procedure used in the assessment of the real heat transfer characteristic of shell and tube and plate heat exchangers. The theoretical fundamentals of the procedure are introduced as well as the measured data collection and processing. The theoretical analysis is focused on the adoption of criterial equations which, subjected to certain verification criteria presented in the paper, provide the most credible value of the convection heat transfer coefficients inside the circular and flat tubes. In the end two case studies are presented, one concerning a shell and tube heat exchanger operational at INCERC Thermal Substation and the other concerning a plate heat exchanger tested on the Laboratory Stand of the Department of Building Services and Efficient Use of Energy in Buildings of INCERC Bucharest.

  11. Heat transfer in plate heat exchanger channels: Experimental validation of selected correlation equations

    Science.gov (United States)

    Cieśliński, Janusz T.; Fiuk, Artur; Typiński, Krzysztof; Siemieńczuk, Bartłomiej

    2016-09-01

    This study is focused on experimental investigation of selected type of brazed plate heat exchanger (PHEx). The Wilson plot approach was applied in order to estimate heat transfer coefficients for the PHEx passages. The main aim of the paper was to experimentally check ability of several correlations published in the literature to predict heat transfer coefficients by comparison experimentally obtained data with appropriate predictions. The results obtained revealed that Hausen and Dittus-Boelter correlations underestimated heat transfer coefficient for the tested PHEx by an order of magnitude. The Aspen Plate code overestimated heat transfer coefficient by about 50%, while Muley-Manglik correlation overestimated it from 1% to 25%, dependent on the value of Reynolds number and hot or cold liquid side.

  12. Generation of a Parabolic Trough Collector Efficiency Curve from Separate Measurements of Outdoor Optical Efficiency and Indoor Receiver Heat Loss: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Kutscher, C.; Burkholder, F.; Stynes, K.

    2010-10-01

    The overall efficiency of a parabolic trough collector is a function of both the fraction of direct normal radiation absorbed by the receiver (the optical efficiency) and the heat lost to the environment when the receiver is at operating temperature. The overall efficiency can be determined by testing the collector under actual operating conditions or by separately measuring these two components. This paper describes how outdoor measurement of the optical efficiency is combined with laboratory measurements of receiver heat loss to obtain an overall efficiency curve. Further, it presents a new way to plot efficiency that is more robust over a range of receiver operating temperatures.

  13. Heat transfer and pressure drop characteristics of nanofluids in a plate heat exchanger.

    Science.gov (United States)

    Kwon, Y H; Kim, D; Li, C G; Lee, J K; Hong, D S; Lee, J G; Lee, S H; Cho, Y H; Kim, S H

    2011-07-01

    In this paper, the heat transfer characteristics and pressure drop of the ZnO and Al2O3 nanofluids in a plate heat exchanger were studied. The experimental conditions were 100-500 Reynolds number and the respective volumetric flow rates. The working temperature of the heat exchanger was within 20-40 degrees C. The measured thermophysical properties, such as thermal conductivity and kinematic viscosity, were applied to the calculation of the convective heat transfer coefficient of the plate heat exchanger employing the ZnO and Al2O3 nanofluids made through a two-step method. According to the Reynolds number, the overall heat transfer coefficient for 6 vol% Al2O3 increased to 30% because at the given viscosity and density of the nanofluids, they did not have the same flow rates. At a given volumetric flow rate, however, the performance did not improve. After the nanofluids were placed in the plate heat exchanger, the experimental results pertaining to nanofluid efficiency seemed inauspicious.

  14. Effect of nozzle-to-plate spacing on the development of a plane jet impinging on a heated plate

    Science.gov (United States)

    Rim, Ben Kalifa; Saïd, Nejla Mahjoub; Bournot, Hervé; Le Palec, Georges

    2016-09-01

    An experimental investigation was carried out to study the behavior of a turbulent air jet impinging on a heated plate. The study of the flow field was performed using a particle image velocimetry. A three-dimensional numerical model with Reynolds stress model has been conducted to examine the global flow. Numerical results agree well with experimental data. The main properties of the fluid occurring between the nozzle and the flat plate are presented. In addition, the effect of the distance between the nozzle exit and the plate (h/e = 14 and 28) were investigated and detailed analysis of the dynamic, turbulent distribution and temperature fields were performed. The wall shear stress and the pressure fields near the heated plate are then explored. Results showed that the mean velocity and the heat transfer characteristics of small nozzle-to-plate spacing are significantly different from those of large nozzle-to-plate spacing.

  15. Hot air from the sun. Domestic heating with air-filled solar collectors; Warme Luft von der Sonne. Luftkollektoren heizen Wohnhaeuser

    Energy Technology Data Exchange (ETDEWEB)

    Brake, M. [Redaktion Sonnenenergie (Germany)

    2006-09-15

    Air-filled solar collectors have been used successfully in industrial and office buildings for many years. With the spread of low-energy buildings, they are also becoming an interesting technology for domestic heating. They have the advantage of direct integration in the architectural concept of a building and direct solar heating of room air. Synergy effects are achieved by combining them with PV systems, ventilation systems, or service water heating systems. (orig.)

  16. Chaotic advection induced heat transfer enhancement in a chevron-type plate heat exchanger

    Science.gov (United States)

    Tohidi, A.; Hosseinalipour, S. M.; Taheri, P.; Nouri, N. M.; Mujumdar, A. S.

    2013-11-01

    The present work examines the role of chaotic mixing as a means of heat transfer enhancement in plate heat exchangers. In order to demonstrate the chaotic behavior, sensitivity to initial conditions and horseshoe maps are visualized. The Nusselt number and the friction factor were computed in the range of reynolds number, 1 < Re < 10. The Nusselt number increases considerably in chaotic models whereas the friction factor increases only marginally.

  17. Development of a Mathematical Lumped Parameters Model for the Heat Transfer Performance of a Solar Collector

    Directory of Open Access Journals (Sweden)

    G. Iordanou

    2011-10-01

    Full Text Available This work describes the developed of a lumped parameter model and demonstrates its practical application. The lumped parameter mathematical model is a useful instrument to be used for rapid determination of design dimensions and operational performance of solar collectors at the designing stage. Such model which incorporates data from relevant Computational Fluid Dynamics design and experimental investigations can provide an acceptable accuracy in predictions and can be used as an effective design tool. A computer algorithm validates the lumped parameter model via a window environment program.

  18. Biological sample collector

    Science.gov (United States)

    Murphy, Gloria A.

    2010-09-07

    A biological sample collector is adapted to a collect several biological samples in a plurality of filter wells. A biological sample collector may comprise a manifold plate for mounting a filter plate thereon, the filter plate having a plurality of filter wells therein; a hollow slider for engaging and positioning a tube that slides therethrough; and a slide case within which the hollow slider travels to allow the tube to be aligned with a selected filter well of the plurality of filter wells, wherein when the tube is aligned with the selected filter well, the tube is pushed through the hollow slider and into the selected filter well to sealingly engage the selected filter well and to allow the tube to deposit a biological sample onto a filter in the bottom of the selected filter well. The biological sample collector may be portable.

  19. Experimental and theoretical analysis of the local condensation heat transfer in a plate heat exchanger

    Science.gov (United States)

    Grabenstein, V.; Kabelac, S.

    2012-11-01

    Plate heat exchanger (PHE) are today widely used in industrial heat transfer applications due to their good thermal performance, modest space requirement, easy accessibility to all areas and their lower capital and operating costs as compared to shell-and-tube heat exchangers. Although authoritative models for the design of PHE used as condensers are missing, the number of applications where a PHE is operating as a condenser increases. On the way to a reliable model based on physical approaches for the prediction of heat transfer and pressure drop during the condensation process inside a PHE, the flow and heat interactions as well as their dependence on the geometrical parameters of the corrugated plates and the operating conditions must be studied in detail. In this work the stepwise procedure for the fundamental construction of such a model is described. An experimental setup was built to analyze the characteristics of the two-phase-flow in PHE. A single gap, consisting of two transparent corrugated plates, was tested with a two-phase flow of air/water and also with boiling refrigerant R365mfc. Flow pattern maps were constructed for plates with corrugation angles of 27 and 63 degrees relative to the direction of flow. Investigations of the local heat transfer coefficients and the pressure drop were done with the same plates. The measurement of the local heat transfer coefficients was carried out by the use of the "Temperature Oscillation InfraRed Thermography" (TOIRT) method. Based on these results three main flow patterns are defined: film flow, bubbly flow and slug flow. For each of the three flow patterns an own model for the heat transfer and pressure drop mechanism are developed and the heat transfer coefficient and the friction factor is calculated with different equations depending on the actual steam quality, mass flow and geometrical parameters by means of a flow pattern map. The theory of the flow pattern based prediction models is proved with own

  20. Investigation of a wire plate micro heat pipe array

    Energy Technology Data Exchange (ETDEWEB)

    Launay, Stephane; Sartre, Valerie; Lallemand, Monique [CETHIL, UMR CNRS 5008, INSA, 20, av. A. Einstein, 69621 Cedex, Villeurbanne (France); Mantelli, Marcia B.H.; Paiva, Kleber Vieira de [Mechanical Engineering Department, Federal University of Santa Catarina UFSC, P.O. Box 476, 88040-900, SC, Florianopolis (Brazil)

    2004-05-01

    In the present work, experimental and theoretical investigations have been conducted on a copper/water wire plate micro heat pipe (MHP). The experimental results show that its effective thermal conductivity is improved by a factor 1.3 as compared to the empty MHP array. A numerical model is used to predict the fluid distribution along the MHP axis, the temperature field and the maximum heat flux corresponding to the MHP capillary limit. The 1D, steady-state hydrodynamic model is based on the conservation equations for the liquid and vapour phases. The wall temperatures are calculated from the thermal resistance network of the wall and the liquid film. A good agreement between the theoretical and experimental data is achieved. The effect of various parameters - contact angle, fluid type, corner angle, fill charge - is theoretically investigated. (authors)

  1. Experimental study and analysis of a novel multi-media plate heat exchanger

    Institute of Scientific and Technical Information of China (English)

    SONG JiWei; WANG Fei; CHENG Lin

    2012-01-01

    The experimental study and analysis of a novel multi-media plate heat exchanger were performed in this paper.This novel multi-media plate heat exchanger was self-developed during the process of the investigation and design of the alpha magnetic spectrometer (AMS) thermal system.The plate of this kind of novel plate heat exchanger is formed by discontinuous structure wave consisting of convex sphere and concave sphere,its heat transfer performance is better than that of the BRI chevron plate heat exchanger,and its resistance characteristics are superior to those of the nornally used 60-degree plate heat exchanger.Furthermore,the mechanism analysis of heat transfer enhancement shows that the spherical wave structure can reduce the local field synergy angle,so as to improve the field synergy degree of velocity vector and temperature gradient vector.

  2. Flat plate solar air heater with latent heat storage

    Science.gov (United States)

    Touati, B.; Kerroumi, N.; Virgone, J.

    2017-02-01

    Our work contains two parts, first is an experimental study of the solar air heater with a simple flow and forced convection, we can use thatlaste oneit in many engineering's sectors as solardrying, space heating in particular. The second part is a numerical study with ansys fluent 15 of the storage of part of this solar thermal energy produced,using latent heat by using phase change materials (PCM). In the experimental parts, we realize and tested our solar air heater in URER.MS ADRAR, locate in southwest Algeria. Where we measured the solarradiation, ambient temperature, air flow, thetemperature of the absorber, glasses and the outlet temperature of the solar air heater from the Sunrise to the sunset. In the second part, we added a PCM at outlet part of the solar air heater. This PCM store a part of the energy produced in the day to be used in peak period at evening by using the latent heat where the PCMs present a grateful storagesystem.A numerical study of the fusion or also named the charging of the PCM using ANSYS Fluent 15, this code use the method of enthalpies to solve the fusion and solidification formulations. Furthermore, to improve the conjugate heat transfer between the heat transfer fluid (Air heated in solar plate air heater) and the PCM, we simulate the effect of adding fins to our geometry. Also, four user define are write in C code to describe the thermophysicalpropriety of the PCM, and the inlet temperature of our geometry which is the temperature at the outflow of the solar heater.

  3. FLOW RESISTANCE AND HEAT TRANSFER CHARACTERISTICS OF A NEW-TYPE PLATE HEAT EXCHANGER

    Institute of Scientific and Technical Information of China (English)

    LUAN Zhi-jian; ZHANG Guan-min; TIAN Mao-cheng; FAN Ming-xiu

    2008-01-01

    A new-type corrugation Plate Heat Exchanger (PHE) was designed. Results from both numerical simulations and experiments showed that the flow resistance of the working fluid in this new corrugation PHE, compared with the traditional chevron-type one, was decreased by more than 50%, and corresponding heat transfer performance was decreased by about 25%. The flow field of the working fluid in the corrugation PHE was transformed and hence performance difference in both flow resistance and heat transfer was generated. Such a novel plate, consisting of longitudinal and transverse corrugations, can effectively avoid the problem of flow path blockage, which will help to extend the application of PHEs to the situation with unclean working fluids.

  4. Experimental and Theoretical Study for Performance Enhancement of Air Solar Collectors by Using Different Absorbers

    Directory of Open Access Journals (Sweden)

    Ahmed A. Mohammad Saleh

    2016-09-01

    Full Text Available An experimental and theoretical study has been done to investigate the thermal performance of different types of air solar collectors, In this work air solar collector with a dimensions of (120 cm x90 cm x12 cm , was tested under climate condition of Baghdad city with a (43° tilt angel by using the absorber plate (1.45 mm thickness, 115 cm height x 84 cm width, which was manufactured from iron painted with a black matt. The experimental test deals with five types of absorber:- Conventional smooth flat plate absorber , Finned absorber , Corrugated absorber plate, Iron wire mesh on absorber And matrix of porous media on absorber . The hourly and average efficiency of the collectors were investigated for three values of mass flow rates (0.016 kg/s to 0.027 kg/s for each type of collector and then the porosity for the last collector type was tested by changing the porosity of porous media. A typical air solar collector has been studied Theoretically to build a standard software for testing any type of air solar collectors with local weather data . From the experimental study it can be seen by using some obstacle material to the air flow (fins, corrugated absorber plate, iron wire mesh porous media on the absorber could be enhanced the efficiencies not less than 4 % for finned type and 8 % for corrugated and 25 % for mesh and 30 % for porous media comparing with flat plate (smooth collector . Theoretically, the results showed that the collector with high convention heat transfer coefficient porous media has high hourly efficiency about (η = 56 % and iron wire mesh on absorber ( η = 52 % , on the other side the minimum performance occurred in the flat plate absorber (η = 28 %. Comparison of results reveals that the theoretical predictions agree reasonably well with experimental results. And the difference between the theoretical and experimental efficiency in general was between (1─ 15 %.

  5. Irreversibility Analysis of Non Isothermal Flat Plate Solar Collectors for Air Heating with a Dimensionless Model

    Directory of Open Access Journals (Sweden)

    Baritto-Loreto Miguel Leonardo

    2013-04-01

    Full Text Available En el presente trabajo, el modelo adimensional desarrollado y validado por Baritto y Bracamonte (2012 para describir el comportamiento térmico de colectores solares de placas planas sin cubierta transparente, se complementa con la ecuación adimensional de balance de entropía para un elemento diferencial de colector solar. El modelo se resuelve para un amplio rango de valores de relaciones de aspecto y número de flujo de masa. A partir de los resultados del modelo se desarrolla un análisis detallado de la influencia de estos parámetros sobre la distribución de irreversibilidades internas a lo largo del colector. Adicionalmente se estudia la influencia de estos parámetros sobre los números de generación de entropía por fricción viscosa, por transferencia de calor y total. Se encuentra que existen combinaciones de los parámetros antes mencionados, para los cuales, la operación del colector es termodinámicamente óptima para números de flujo de masa elevados.

  6. Irreversibility Analysis of Non Isothermal Flat Plate Solar Collectors for Air Heating with a Dimensionless Model

    Directory of Open Access Journals (Sweden)

    Acosta-Flores José Jesús

    2013-04-01

    Full Text Available En ingeniería nos enfrentamos con problemas tan diversos como la elección del sitio donde debe construirse una carretera, una presa, un puente o un aeropuerto. Las consecuencias de tomar decisiones equivocadas son tan grandes que es conveniente contar con un método eficiente para enfrentar dichas situaciones, ya que siempre existe incertidumbre sobre lo que puede acontecer. En este artículo se presenta dicho método a través de un ejemplo sobre un sistema de protección de huracanes en el que dos actores serán fundamentales: el decisor y el analista. Se ha elegido este ejemplo porque permitiría tomar decisiones que disminuyan los daños que ocasionan los huracanes en nuestro país.

  7. Step tracking program for concentrator solar collectors

    Science.gov (United States)

    Ciobanu, D.; Jaliu, C.

    2016-08-01

    The increasing living standards in developed countries lead to increased energy consumption. The fossil fuel consumption and greenhouse gas effect that accompany the energy production can be reduced by using renewable energy. For instance, the solar thermal systems can be used in temperate climates to provide heating during the transient period or cooling during the warmer months. Most used solar thermal systems contain flat plate solar collectors. In order to provide the necessary energy for the house cooling system, the cooling machine uses a working fluid with a high temperature, which can be supplied by dish concentrator collectors. These collectors are continuously rotated towards sun by biaxial tracking systems, process that increases the consumed power. An algorithm for a step tracking program to be used in the orientation of parabolic dish concentrator collectors is proposed in the paper to reduce the consumed power due to actuation. The algorithm is exemplified on a case study: a dish concentrator collector to be implemented in Brasov, Romania, a location with the turbidity factor TR equal to 3. The size of the system is imposed by the environment, the diameter of the dish reflector being of 3 meters. By applying the proposed algorithm, 60 sub-programs are obtained for the step orientation of the parabolic dish collector over the year. Based on the results of the numerical simulations for the step orientation, the efficiency of the direct solar radiation capture on the receptor is up to 99%, while the energy consumption is reduced by almost 80% compared to the continuous actuation of the concentrator solar collector.

  8. Open fibre reinforced plastic (FRP) flat plate collector (FPC) and spray network systems for augmenting the evaporation rate of tannery effluent (soak liquor)

    Energy Technology Data Exchange (ETDEWEB)

    Srithar, K. [Department of Mechanical Engineering, Thiagarajar College of Engineering, Madurai 625 015 (India); Mani, A. [Department of Mechanical Engineering, Indian Institute of Technology, Madras, Chennai 600 036 (India)

    2007-12-15

    Presently, tanneries in Tamilnadu, India are required to segregate the effluent of soaking and pickling sections from other wastewater streams and send it to shallow solar pans for evaporation to avoid land pollution. A large area of solar pans is required for evaporating the water in the effluent at salt concentration in the range of 4-5%. An experimental study has been made by using fibre reinforced plastic flat plate collector (FRP-FPC) and spray system in a pilot plant with a capacity to handle 5000 l per day, which increases the evaporation rate. After increasing the salt concentration level to near saturation limit, the concentrated liquid was sent to conventional solar pans for its continued evaporation and recovery of salt. In this improved system, the rate of evaporation was found to be 30-40% more than that in the conventional solar pans. The performance is compared with the theoretically simulated performance. (author)

  9. Ferrocene-Boronic Acid-Fructose Binding Based on Dual-Plate Generator-Collector Voltammetry and Square-Wave Voltammetry.

    Science.gov (United States)

    Li, Meng; Xu, Su-Ying; Gross, Andrew J; Hammond, Jules L; Estrela, Pedro; Weber, James; Lacina, Karel; James, Tony D; Marken, Frank

    2015-06-10

    The interaction of ferrocene-boronic acid with fructose is investigated in aqueous 0.1 m phosphate buffer at pH 7, 8 and 9. Two voltammetric methods, based on 1) a dual-plate generator-collector micro-trench electrode (steady state) and 2) a square-wave voltammetry (transient) method, are applied and compared in terms of mechanistic resolution. A combination of experimental data is employed to obtain new insights into the binding rates and the cumulative binding constants for both the reduced ferrocene-boronic acid (pH dependent and weakly binding) and for the oxidised ferrocene-boronic acid (pH independent and strongly binding).

  10. Short-Term Solar Collector Power Forecasting

    DEFF Research Database (Denmark)

    Bacher, Peder; Madsen, Henrik; Perers, Bengt

    2011-01-01

    This paper describes a new approach to online forecasting of power output from solar thermal collectors. The method is suited for online forecasting in many applications and in this paper it is applied to predict hourly values of power from a standard single glazed large area flat plate collector....... The method is applied for horizons of up to 42 hours. Solar heating systems naturally come with a hot water tank, which can be utilized for energy storage also for other energy sources. Thereby such systems can become an important part of energy systems with a large share of uncontrollable energy sources......, such as wind power. In such a scenario online forecasting is a vital tool for optimal control and utilization of solar heating systems. The method is a two-step scheme, where first a non-linear model is applied to transform the solar power into a stationary process, which then is forecasted with robust time...

  11. Fin-tube solar collectors

    Science.gov (United States)

    1980-01-01

    Report presents test procedures and results of thermal-performance evaluation of seven commercial fin tube (liquid) solar collector-absorber plates. Tests were conducted indoors at Marshall Space Flight Center Solar simulator. Results are graphically shown along with supporting test data and summary, indicating efficiency as function of collector inlet temperature.

  12. Development of optimization method for plate heat exchanger with undulation

    Directory of Open Access Journals (Sweden)

    Dvořák Václav

    2016-01-01

    Full Text Available The article deals with optimization of undulated heat transfer surface of plate heat exchanger. The goal of optimization is not only to increase effectiveness of heat transfer but also to reduce the pressure drop. A combined pattern of undulation which combines herringbone pattern and wavy pattern was optimized and best values of four parameters were found; angle of herringbone pattern, number, phase and amplitude of longitudinal waves of wavy pattern. The optimization procedure looked for maximum of objective function which was a linear combination of effectiveness and pressure drop. We used simple Monte Carlo method and the optimum was searched for four values of reference pressure drop. Four different optimization were run and we investigated the effect of various definition of objective function and parameters of undulation. It was found that during optimization of combined pattern, the herringbone pattern is more favoured than wavy pattern. It is caused by the fact that herringbone pattern was described by the only one free parameter, which was the angle of undulation, and therefore it is more likely to be found by a stochastic method. This assumption was confirmed when simple wavy pattern was optimized and higher values of objective function and effectiveness were found.

  13. Performance of plate type heat exchanger as ammonia condenser

    Science.gov (United States)

    Rivera, Andrew

    In this study, I experimentally analyzed the performance of a commercial semi-welded plate type heat exchanger (PHE) for use with ammonia systems. I determined performance parameters such as overall heat transfer coefficient, capacity, and pressure drop of the semi-welded PHE. This was analyzed by varying different parameters which demonstrated changes in overall heat transfer coefficient, capacity, and pressure drop. Both water and ammonia flow rates to the semi-welded PHE were varied independently, and analyzed in order to understand how changes in flow rates affected performance. Inlet water temperature was also varied, in order to understand how raising condenser water inlet temperature would affect performance. Finally, pressure drop was monitored to better understand the performance limitations of the semi-welded PHE. Testing of the semi-welded will give insight as to the performance of the semi-welded PHE in a potential ocean thermal energy conversion system, and whether the semi-welded PHE is a viable choice for use as an ammonia condenser.

  14. Heat transfer to immiscible liquid mixtures in a spiral plate heat exchanger

    Directory of Open Access Journals (Sweden)

    S. Sathiyan

    2013-06-01

    Full Text Available This work presents new predictive correlations for heat transfer to immiscible liquid-liquid mixtures in a spiral plate heat exchanger. Liquid-liquid heat transfer studies were carried out in spiral plate heat exchangers for the water-octane, water-kerosene, and water-dodecane systems. For each composition of the mixture, the mass flow rate of the cold fluid was varied, keeping that of the hot fluid and the fluid inlet temperatures constant. Two-phase cold flow rates were in the laminar range, while the hot fluid flow was turbulent. Calculations of the LMTD (log mean temperature difference correction factor showed that the flow was countercurrent. Heat transfer coefficients of the two-phase liquids were found to be strongly dependent on the composition of the liquid mixture and exhibited abrupt transitions as a function of the compositions. Given the absence of predictive correlations in the literature that sufficiently capture this compositiondependence, new empirical correlations were developed using part of the experimental data, with the composition of the cold fluid as an explicit variable. Statistical analysis of the regression yielded satisfactory results. The correlations were tested against the rest of the experimental data and were found to predict heat transfer coefficients within ± 15%. These preliminary studies should be useful in designing compact exchangers for handling two-phase water-organics mixtures.

  15. High-performance solar collector

    Science.gov (United States)

    Beekley, D. C.; Mather, G. R., Jr.

    1979-01-01

    Evacuated all-glass concentric tube collector using air or liquid transfer mediums is very efficient at high temperatures. Collector can directly drive existing heating systems that are presently driven by fossil fuel with relative ease of conversion and less expense than installation of complete solar heating systems.

  16. Effect of Localized Heating on Three-Dimensional Flat-Plate Oscillating Heat Pipe

    Directory of Open Access Journals (Sweden)

    S. M. Thompson

    2010-01-01

    Full Text Available An experimental investigation was conducted, both thermally and visually, on a three-dimensional flat-plate oscillating heat pipe (3D FP-OHP to characterize its performance under localized heat fluxes while operating in the bottom heating mode and charged with acetone at a filling ratio of 0.73. The cooling area was held constant and three heating areas of 20.16 cm2, 11.29 cm2, and 1.00 cm2 were investigated, respectively. It was found that as the heating area was reduced and higher heat fluxes were imposed, the thermal resistance increased and the amplitude of thermal oscillations in the evaporator increased and became more chaotic. Using neutron radiography, it was observed that fluid oscillations did not occur in outer channels located away from the region of local heating. Although the thermal resistance increased during localized heating, a maximum heat flux of 180 W/cm2 was achieved with the average evaporator temperature not exceeding 90∘C.

  17. Estimation of pressure drop in gasket plate heat exchangers

    Directory of Open Access Journals (Sweden)

    Neagu Anisoara Arleziana

    2016-06-01

    Full Text Available In this paper, we present comparatively different methods of pressure drop calculation in the gasket plate heat exchangers (PHEs, using correlations recommended in literature on industrial data collected from a vegetable oil refinery. The goal of this study was to compare the results obtained with these correlations, in order to choose one or two for practical purpose of pumping power calculations. We concluded that pressure drop values calculated with Mulley relationship and Buonopane & Troupe correlation were close and also Bond’s equation gave results pretty close to these but the pressure drop is slightly underestimated. Kumar correlation gave results far from all the others and its application will lead to oversize. In conclusion, for further calculations we will chose either the Mulley relationship or the Buonopane & Troupe correlation.

  18. 槽式DSG太阳能集热系统模拟分析%Simulation of Heat Transfer for Parabolic Trough DSG Solar Collectors

    Institute of Scientific and Technical Information of China (English)

    韦彪; 朱天宇; 刘德有

    2012-01-01

    以采用真空集热管的一次通过式槽式DSG太阳能集热器为研究对象。基于集热器管内水工质的流型与传热特性,建立了集热器稳态传热模型,并验证了模型及计算方法的合理性。分析了当出口为400℃过热蒸汽时,集热器传热受太阳辐射强度、管径、水工质入口参数等的影响规律。结果表明集热器的传热效果取决于周围环境的边界条件以及集热器结构参数和水工质运行参数的选取,本文结论为DSG集热器的设计及运行提供了理论参考依据。%Once-through trough DSG collectors were researched in the paper.Heat transfer models of once-through parabolic trough DSG solar collectors under steady-state were established based on the flow patterns and heat transfer characteristics of water in absorber tubes.Through theoretical analysis,numerical models are proved correct.For dry steam exit at 400℃,heat transfer characteristics of collectors influenced by solar radiation,tube diameter,inlet temperature,inlet pressure and mass flow rate were analyzed by this model.The results of calculation and analysis, which indicate that the heat transfer effects of once- through parabolic trough DSG solar collectors depend on boundary conditions and the choices of parameters,provide a theoretical foundation for the design and operation of parabolic trough DSG solar collectors.

  19. Heat transfer studies in a spiral plate heat exchanger for water: palm oil two phase system

    Directory of Open Access Journals (Sweden)

    S. Ramachandran

    2008-09-01

    Full Text Available Experimental studies were conducted in a spiral plate heat exchanger with hot water as the service fluid and the two-phase system of water – palm oil in different mass fractions and flow rates as the cold process fluid. The two phase heat transfer coefficients were correlated with Reynolds numbers (Re in the form h = a Re m, adopting an approach available in literature for two phase fluid flow. The heat transfer coefficients were also related to the mass fraction of palm oil for identical Reynolds numbers. The two-phase multiplier (ratio of the heat transfer coefficient of the two phase fluid and that of the single phase fluid was correlated with the Lockhart Martinelli parameter in a polynomial form. This enables prediction of the two-phase coefficients using single-phase data. The predicted coefficients showed a spread of ± 10 % in the laminar range.

  20. A Novel Heat Pipe Plate for Passive Thermal Control of Fuel Cells Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR project aims to develop a lightweight, highly thermally and electrically conductive heat pipe plate for passive removal of the heat from the individual...

  1. Technical evaluation of a solar heating system having conventional hydronic solar collectors and a radiant panel slab. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Starr, R.J.

    1984-04-01

    A simple innovative solar heating design (Solar Option One) using conventional hydronic solar collectors and a radiant panel slab was constructed. An objective of hybrid solar design is to combine the relative advantages of active and passive design approaches while minimizing their respective disadvantages. A test house using the Solar Option One heating system was experimentally monitored to determine its energy based performance during the 1982-83 heating season. The test residence is located in Lyndonville, Vermont, an area which has a characteristically cold and cloudy climate. The two story residence has a floor area of about 1400 square feet and is constructed on a 720 square foot 5.5 inch thick floor slab. A 24 inch packed gravel bed is located beneath the slab and the slab-gravel bed is insulated by two inches of polystyrene insulation. The test building is of frame construction and uses insulation levels which have become commonplace throughout the country. The structure would not fall into the superinsulated category but was tightly constructed so as to have a low infiltration level. The building is sun-tempered in that windows were concentrated somewhat on the South side and all but avoided on the North. A solar greenhouse on the South side of the building was closed off from the structure permanently throughout the testing so as to better observe the solar heating invention without confounding variables. The monitoring equipment generated an internal gain of about 17,000 BTUs per day, roughly the equivalent of occupancy by two persons. A full description of the experimental testing program is given. System efficiency and performance are reported.

  2. Solar collector parameter identification from unsteady data by a discrete-gradient optimization algorithm

    Science.gov (United States)

    Hotchkiss, G. B.; Burmeister, L. C.; Bishop, K. A.

    1980-01-01

    A discrete-gradient optimization algorithm is used to identify the parameters in a one-node and a two-node capacitance model of a flat-plate collector. Collector parameters are first obtained by a linear-least-squares fit to steady state data. These parameters, together with the collector heat capacitances, are then determined from unsteady data by use of the discrete-gradient optimization algorithm with less than 10 percent deviation from the steady state determination. All data were obtained in the indoor solar simulator at the NASA Lewis Research Center.

  3. Heat Conduction in a Functionally Graded Plate Subjected to Finite Cooling/Heating Rates: An Asymptotic Solution

    Directory of Open Access Journals (Sweden)

    Zhihe Jin

    2011-12-01

    Full Text Available This work investigates transient heat conduction in a functionally graded plate (FGM plate subjected to gradual cooling/heating at its boundaries. The thermal properties of the FGM are assumed to be continuous and piecewise differentiable functions of the coordinate in the plate thickness direction. A linear ramp function describes the cooling/heating rates at the plate boundaries. A multi-layered material model and Laplace transform are employed to obtain the transformed temperatures at the interfaces between the layers. An asymptotic analysis and an integration technique are then used to obtain a closed form asymptotic solution of the temperature field in the FGM plate for short times. The thermal stress intensity factor (TSIF for an edge crack in the FGM plate calculated based on the asymptotic temperature solution shows that the asymptotic solution can capture the peak TSIFs under the finite cooling rate conditions.

  4. Study of natural and forced heat transfer coefficients on a vertical heated plate

    Directory of Open Access Journals (Sweden)

    Stefan-Mugur SIMIONESCU

    2015-12-01

    Full Text Available Infrared thermography measurement technique is a methodology which detects infrared energy emitted from an object, converts it to temperature, and displays images of temperature distribution. It is a powerful non-invasive methodology for the analysis of surface temperature measurements. The infrared camera represents a truly two-dimensional transducer, allowing for considerably high accurate measurements of surface temperature maps even in the presence of relatively high spatial gradients. The infrared thermography measurement technique is used in this experimental study to estimate the heat transfer coefficient over a flat plate. The main objective of this study was to get insights about the heat transfer in solids and on solid surfaces and its quantitative measurement. An infrared camera was used to calculate the temperature distribution for the evaluation of the heat transfer coefficient. Two study cases were taken into account: a first case without any fluid jet is calculated, where natural convection over the plate emerges due to the buoyancy effect, and a second case where a circular air jet is impinged on the surface - in this case the forced convection heat transfer coefficient has been evaluated.

  5. THERMAL PERFORMANCE INVESTIGATION OF EVACUATED TUBE HEAT PIPE SOLAR COLLECTOR WITH NANOFLUID

    OpenAIRE

    N. H. Mujawar*, S. M. Shaikh

    2016-01-01

    Solar energy, being abundant and widespread in its availability, makes it one of the most attractive sources of energies. Tapping this energy will not only help in bridging the gap between demand and supply of electricity but shall also save money in the long run. A Solar Water Heating System (SWHS) is a device that makes available the thermal energy of the incident solar radiation for use in various applications by heating the water. Solar energy is one of the cleaner forms of renewable ener...

  6. Study on the automatic process of line heating for pillow shape plate

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    This paper focuses on the process for pillow shape plate by line heating technique, which is widely applied in the production of ship hull. Based on the analysis of primary parameters and experimental data in line heating process, the amount of local contraction generated by line heating has been illustrated. Then, combining with the computational result of local deformation determined by shell plate development, an optimization method for line heating parameters has been studied. This prediction system may provide rational arrangements of heating lines and technical parameters of process. By integrating the prediction system into the line heating robot for pillow shape plate, the automatic process of line heating for pillow shape plate can be achieved.

  7. Liquid cooled plate heat exchanger for battery cooling of an electric vehicle (EV)

    Science.gov (United States)

    Rahman, M. M.; Rahman, H. Y.; Mahlia, T. M. I.; Sheng, J. L. Y.

    2016-03-01

    A liquid cooled plate heat exchanger was designed to improve the battery life of an electric vehicle which suffers from premature aging or degradation due to the heat generation during discharging and charging period. Computational fluid dynamics (CFD) was used as a tool to analyse the temperature distribution when a constant surface heat flux was set at the bottom surface of the battery. Several initial and boundary conditions were set based on the past studies on the plate heat exchanger in the simulation software. The design of the plate heat exchanger was based on the Nissan Leaf battery pack to analyse the temperature patterns. Water at different mass flow rates was used as heat transfer fluid. The analysis revealed the designed plate heat exchanger could maintain the surface temperature within the range of 20 to 40°C which is within the safe operating temperature of the battery.

  8. Comparative study of Nusselt number for a single phase fluid flow using plate heat exchanger

    Directory of Open Access Journals (Sweden)

    Shanmugam Rajasekaran

    2016-01-01

    Full Text Available In this study, the plate heat exchangers are used for various applications in the industries for heat exchange process such as heating, cooling and condensation. The performance of plate heat exchanger depends on many factors such as flow arrangements, plate design, chevron angle, enlargement factor, type of fluid used, etc. The various Nusselt number correlations are developed by considering that the water as a working fluid. The main objective of the present work is to design the experimental set-up for a single phase fluid flow using plate heat exchanger and studied the heat transfer performance. The experiments are carried out for various Reynolds number between 500 and 2200, the heat transfer coefficients are estimated. Based on the experimental results the new correlation is developed for Nusselt number and compared with an existing correlation.

  9. NUMERICAL STUDY ON FLOW DISTRIBUTION IN PLATE-FIN HEAT EXCHANGERS

    Institute of Scientific and Technical Information of China (English)

    张哲; 厉彦忠

    2003-01-01

    Objective To investigate the flow distribution in plate-fin heat exchangers and optimize the design of header configuration for plate-fin heat exchangers. Methods A mathematical model of header was proposed. The effects of the header configuration on the flow distribution in plate-fin heat exchangers were investigated by CFD. The second header configuration with a two-stage-distributing structure was brought forward to improve the performance of flow distribution. Results It is found that the flow maldistribution is very serious in the direction of header length for the conventional header used in industry. The numerical predictions indicate that the improved header configurations can effectively improve the performance of flow distribution in plate-fin heat exchangers. Conclusion The numerical simulation confirms that CFD should be a suitable tool for predicting the flow distribution. The method has a wide variety of applications in the design of plate-fin heat exchangers.

  10. Cysteine-cystine redox cycling in a gold-gold dual-plate generator-collector microtrench sensor.

    Science.gov (United States)

    Hammond, Jules L; Gross, Andrew J; Estrela, Pedro; Iniesta, Jesus; Green, Stephen J; Winlove, C Peter; Winyard, Paul G; Benjamin, Nigel; Marken, Frank

    2014-07-15

    Thiols and disulfides are ubiquitous and important analytical targets. However, their redox properties, in particular on gold sensor electrodes, are complex and obscured by strong adsorption. Here, a gold-gold dual-plate microtrench dual-electrode sensor with feedback signal amplification is demonstrated to give well-defined (but kinetically limited) steady-state voltammetric current responses for the cysteine-cystine redox cycle in nondegassed aqueous buffer media at pH 7 down to micromolar concentration levels.

  11. Experimental anaerobic digestion generator coupled at a plan plates solar collector; Biodigestor experimental acoplado a coletor solar de placas planas

    Energy Technology Data Exchange (ETDEWEB)

    Kaneshiro, Tsuneharu [Brasilia Univ., DF (Brazil); Venanzi, D. [Sao Paulo Univ., Sao Carlos, SP (Brazil). Escola de Engenharia; Medeiros, J.T.N. de [Rio Grande do Norte Univ., Natal, RN (Brazil)

    1987-12-31

    Analysis of results of research in course in solar energy used as heat source to anaerobic degradation in organic matter are presented; water is circulated around the generator to rise and maintain a constant process. (author). 16 refs., 2 figs

  12. To the Problem of Designing Water Heating Solar Systems with Flat Collectors for Individual Dwellings

    Directory of Open Access Journals (Sweden)

    B. M. Khroustalev

    2011-01-01

    Full Text Available The variant of efficient combination of two renewable energy sources as a biogas system and a water heating solar system has been considered for power supply of individual dwellings. Criteria dependence has been suggested for determination of solar system power efficiency. Its legitimacy has been proved by an experiment. Power efficient solar system has been proposed with peculiar features of its designing and due account of energy flow distribution in technology of biogas production.

  13. Simple procedure for predicting long-term average performance of nonconcentration and of concentrating solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Collares-Pereira, M.; Rabl, A.

    1978-06-01

    The Liu and Jordan method of calculating long term average energy collection of flat plate collectors is simplified (by about a factor of 4), and generalized to all collectors, concentration and nonconcentrating. The only meteorological input needed are the long term average daily total hemispherical insolation H/sub h/ on a horizontal surface and, for thermal collectors the average ambient temperature. The collector is characterized by optical efficiency, heat loss (or U-value), heat extraction efficiency, concentration ratio and tracking mode. An average operating temperature is assumed. Interaction with storage can be included by combining the present model with the f-chart method of Beckman, Klein and Duffie. Formulas and examples are presented for five collector types: flat plate, compound parabolic concentrator, concentrator with E.-W. tracking axis, concentrator with polar tracking axis, and concentrator with two axis tracking. The examples show that even for relatively low temperature applications and cloudy climates (50/sup 0/C in New York in February), concentrating collectors can outperform the flat plate. The method has been validated against hourly weather data (with measurements of hemispherical and beam insolation), and has been found to have an average accuracy better than 3% for the long term average radiation available to solar collectors. The suitability of this method for comparison studies is illustrated by comparing in a location independent manner the radiation availability for several collector types or operating conditions: two axis tracking versus one axis tracking; polar tracking axis versus east-west tracking axis; fixed versus tracking flat plate; effect of ground reflectance; and acceptance for diffuse radiation as function of concentration ratio.

  14. An Experimentally Validated Numerical Modeling Technique for Perforated Plate Heat Exchangers.

    Science.gov (United States)

    White, M J; Nellis, G F; Kelin, S A; Zhu, W; Gianchandani, Y

    2010-11-01

    Cryogenic and high-temperature systems often require compact heat exchangers with a high resistance to axial conduction in order to control the heat transfer induced by axial temperature differences. One attractive design for such applications is a perforated plate heat exchanger that utilizes high conductivity perforated plates to provide the stream-to-stream heat transfer and low conductivity spacers to prevent axial conduction between the perforated plates. This paper presents a numerical model of a perforated plate heat exchanger that accounts for axial conduction, external parasitic heat loads, variable fluid and material properties, and conduction to and from the ends of the heat exchanger. The numerical model is validated by experimentally testing several perforated plate heat exchangers that are fabricated using microelectromechanical systems based manufacturing methods. This type of heat exchanger was investigated for potential use in a cryosurgical probe. One of these heat exchangers included perforated plates with integrated platinum resistance thermometers. These plates provided in situ measurements of the internal temperature distribution in addition to the temperature, pressure, and flow rate measured at the inlet and exit ports of the device. The platinum wires were deposited between the fluid passages on the perforated plate and are used to measure the temperature at the interface between the wall material and the flowing fluid. The experimental testing demonstrates the ability of the numerical model to accurately predict both the overall performance and the internal temperature distribution of perforated plate heat exchangers over a range of geometry and operating conditions. The parameters that were varied include the axial length, temperature range, mass flow rate, and working fluid.

  15. Analysis of Heat Transfer Behaviour of the Conduction Cold Plate System

    Institute of Scientific and Technical Information of China (English)

    YangChun-xin; DangChao-Bin

    1995-01-01

    The heat-transfer behaviour of the conduction cold plate system used for avionics is investigated in this paper.The steady-state temperature profile for the cold plate is derived and the relationship between the coolant mass flowrate,the heat load and the highest cold plate temperature is established.A model is proposed to describe the transient thermal rosponse of the cold plate under thermal shock condition.The analytic solution of the transient heat transfer within the cold plate is provided.The results of this paper agree with those of the finite element method and can be used for the structural design and performance evaluation of cold plate system.

  16. Heat transfer in flow past a continuously moving semi-infinite flat plate in transverse magnetic field with heat flux

    Digital Repository Service at National Institute of Oceanography (India)

    Murty, T.V.R.

    Thermal boundary layer on a continuously moving semi-infinite flat plate in the presence of transverse magnetic field with heat flux has been examined. Similarity solutions have been derived and the resulting equations are integrated numerically...

  17. A solar energy collector

    Energy Technology Data Exchange (ETDEWEB)

    Vasil' yev, L.L.; Avakyan, Yu.V.; Bogdanov, V.M.; Gagiyan, L.A.; Grakovich, L.P.; Karapetyan, G.S.; Morgun, V.A.

    1984-01-01

    A collector whose primary component is a heating pipe is proposed. The evaporation zone located in the lower half of the heating pipe has an external absorption coating. Chambers that open upward and contain the evaporating fluid are mounted within this region along the top. In order to improve operational reliability of the collector, these chambers are mounted on one coated wall; the area of projection of each of the chambers onto the horizontal plane is greater than the area of the projection of each of the chambers placed above it. The coating may be in the form of photocells; a filter is mounted on the chamber side inside the evaporation zone. The evaporation zone may take the form of a cylinder with a segmented base; the photocells are mounted on a flat section of the lateral surface. The collector may be used to cool the photocells.

  18. Heat Transfer Modeling of Phase Change Materials in Multiple Plates Heat Exchanger

    Directory of Open Access Journals (Sweden)

    M. Alipanah

    2013-12-01

    Full Text Available Nowadays, given the increasing importance of energy sources, the possibility of energy storage in the heat exchangers through the Phase Change Materials (PCM and releasing it when needed have been extremely essential. This study seeks to model the domestic water heat system in which the paraffin is as the phase change material and it stores the solar energy. The behavior of a PCM plate was studied by writing the governing equations and solving them as the one-dimensional, implicit method and through numerical calculation of the method equations. Given the confirmed accuracy of performed modeling by the results of similar studies for the complete melting and solidification of PCM, the application of this system seems appropriate for the solar domestic water heaters.

  19. Indoor test for thermal performance evaluation of Libbey-Owens-Ford solar collector. [using a solar simulator

    Science.gov (United States)

    Shih, K.

    1977-01-01

    The thermal performance of a flat plate solar collector that uses liquid as the heat transfer medium was investigated under simulated conditions. The test conditions and thermal performance data obtained during the tests are presented in tabular form, as well as in graphs. Data obtained from a time constant test and incident angle modifier test, conducted to determine transient effect and the incident angle effect on the collector, are included.

  20. Results of IEA SHC Task 45: Large Scale Solar Heating and Cooling Systems. Subtask A: “Collectors and Collector Loop”

    DEFF Research Database (Denmark)

    Bava, Federico; Nielsen, Jan Erik; Knabl, Samuel;

    2016-01-01

    The IEA SHC Task 45 Large Scale Solar Heating and Cooling Systems, carried out between January 2011 and December 2014, had the main objective to assist in the development of a strong and sustainable market of large solar heating systems by focusing on high performance and reliability of systems. ...

  1. Plate Fin Heat Exchanger Model with Axial Conduction and Variable Properties

    CERN Document Server

    Hansen, B J; Klebaner, A; 10.1063/1.4706971

    2012-01-01

    Future superconducting radio frequency (SRF) cavities, as part of Project X at Fermilab, will be cooled to superfluid helium temperatures by a cryogenic distribution system supplying cold supercritical helium. To reduce vapor fraction during the final Joule-Thomson (J-T) expansion into the superfluid helium cooling bath, counter-flow, plate-fin heat exchangers will be utilized. Due to their compact size and ease of fabrication, plate-fin heat exchangers are an effective option. However, the design of compact and high-effectiveness cryogenic heat exchangers operating at liquid helium temperatures requires consideration of axial heat conduction along the direction of flow, in addition to variable fluid properties. Here we present a numerical model that includes the effects of axial conduction and variable properties for a plate fin heat exchanger. The model is used to guide design decisions on heat exchanger material choice and geometry. In addition, the J-T expansion process is modeled with the heat exchanger ...

  2. Mathematical Modeling of Quasi Static Thermoelastic Transient behavior of thick circular plate with Internal Heat Generation

    Directory of Open Access Journals (Sweden)

    C. M. Bhongade

    2014-09-01

    Full Text Available The present paper deals with the determination of displacement and thermal transient stresses in a thick circular plate with internal heat generation. External arbitrary heat supply is applied at the upper surface of a thick circular plate, whereas the lower surface of a thick circular plate is insulated and heat is dissipated due to convection in surrounding through lateral surface. Here we compute the effects of internal heat generation of a thick circular plate in terms of stresses along radial direction. The governing heat conduction equation has been solved by using integral transform method. The results are obtained in series form in terms of Bessel’s functions and the results for temperature change and stresses have been computed numerically and illustrated graphically.

  3. Three-Dimensional Heat Transfer Modeling of a Moving Plate in Forming Process Applications

    Science.gov (United States)

    Lavella, Mario; Maizza, Giovanni; Borgna, Massimo; Firrao, Donato

    2004-06-01

    A three-dimensional heat transfer model of glass plates heating and cooling has been developed to study their thermal tempering. The furnace being modeled is of a tunnel type, in which the glass plate alternates translational motions with back and forth mouvements with a specified law. An appropriate implementation of a moving (transient) convection/radiation boundary condition has been proposed to describe the heat transfer exchanged between the glass surfaces and the furnace environment. The model results have been experimentally validated by a scanning pyrometer which detects the pointwise temperature of the upper surface of the plate at the exit of the furnace.

  4. Evaluation of Test Method for Solar Collector Efficiency

    OpenAIRE

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    2006-01-01

    The test method of the standard EN12975-2 (European Committee for Standardization, 2004) is used by European test laboratories to determine the efficiency of solar collectors. In the test methods the mean solar collector fluid temperature in the solar collector, Tm is determined by the approximated equation where Tin is the inlet temperature to the collector and Tout is the outlet temperature from the collector. The specific heat of the solar collector fluid is in the test method as an approx...

  5. Quality and efficiency of solar collectors in Sweden

    Science.gov (United States)

    Wennerholm, H.

    Transparent or translucent insulation materials (TIM's) represent a new class of materials with a high potential for increasing the efficiency of solar thermal conversion systems. A large number of materials have been subjected to theoretical and experimental investigation. If materials that suppress heat losses are transparent to solar radiation, vacuum, certain gases, convection barriers, etc., then they can be regarded as TIM's. Exploratory field and laboratory studies of degraded FEP-film convection barriers in flat plate thermal solar collectors are described. The study related to collectors that had been operating in Sweden for periods of one year to ten years. Both physical, functional (thermal) and chemical aspects of degradation were considered. The report identifies the mistakes made so that they need not be repeated by the solar collector manufacturers in the future.

  6. Analysis of Flat-Plate Solar Array and Solar Lantern

    Directory of Open Access Journals (Sweden)

    P. L. N. V. Aashrith

    2014-05-01

    Full Text Available A very detailed theortical analysis of a solar array has been carried out based on established values of solar radiation data to predict the performance of solar lamp . The analysis is based on established theory about flat-plate collectors. Top heat loss coefficient (Ut, Bottom heat loss coefficient (Ub, Overall heat loss coefficient (Ul, Useful energy (Qu, efficiency (hp of the flat-plate solar array and efficiency (hl of the solar lantern has been calculated.

  7. Modeling of the heat transfer performance of plate-type dispersion nuclear fuel elements

    Science.gov (United States)

    Ding, Shurong; Huo, Yongzhong; Yan, XiaoQing

    2009-08-01

    Considering the mutual actions between fuel particles and the metal matrix, the three-dimensional finite element models are developed to simulate the heat transfer behaviors of dispersion nuclear fuel plates. The research results indicate that the temperatures of the fuel plate might rise more distinctly with considering the particle swelling and the degraded surface heat transfer coefficients with increasing burnup; the local heating phenomenon within the particles appears when their thermal conductivities are too low. With rise of the surface heat transfer coefficients, the temperatures within the fuel plate decrease; the temperatures of the fuel plate are sensitive to the variations of the heat transfer coefficients whose values are lower, but their effects are weakened and slight when the heat transfer coefficients increase and reach a certain extent. Increasing the heat generation rate leads to elevating the internal temperatures. The temperatures and the maximum temperature differences within the plate increase along with the particle volume fractions. The surface thermal flux goes up along with particle volume fractions and heat generation rates, but the effects of surface heat transfer coefficients are not evident.

  8. Energy and exergy analysis of PV/T air collectors connected in series

    Energy Technology Data Exchange (ETDEWEB)

    Dubey, Swapnil; Solanki, S.C. [Centre for Energy Studies, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016 (India); Tiwari, Arvind [Department of Design, Production and Management, University of Twente (Netherlands)

    2009-08-15

    In this paper an attempt has been made to derive the analytical expressions for N hybrid photovoltaic/thermal (PV/T) air collectors connected in series. The performance of collectors is evaluated by considering the two different cases, namely, Case I (air collector is fully covered by PV module (glass to glass) and air flows above the absorber plate) and Case II (air collector is fully covered by PV module (glass to glass) and air flows below the absorber plate). This paper shows the detailed analysis of energy, exergy and electrical energy by varying the number of collectors and air velocity considering four weather conditions (a, b, c and d type) and five different cities (New Delhi, Bangalore, Mumbai, Srinagar, and Jodhpur) of India. It is found that the collectors fully covered by PV module and air flows below the absorber plate gives better results in terms of thermal energy, electrical energy and exergy gain. Physical implementation of BIPV system has also been evaluated. If this type of system is installed on roof of building or integrated with building envelope will simultaneously fulfill the electricity generation for lighting purpose and hot air can be used for space heating or drying. (author)

  9. A flat solar collector built from galvanized steel plate, working by thermosyphonic flow, optimized for Mexican conditions; Un colector solar plano construido de lamina de acero galvanizada, operando por flujo termosifonico, optimizado para las condiciones mexicanas

    Energy Technology Data Exchange (ETDEWEB)

    Marroquin de Jesus, A; Olivares Ramirez, J.M.; Ramos Lopez, G.A.; Pless, R.C. [Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Instituto Politecnico Nacional, Unidad Queretaro (Mexico)]. E-mail: amarroquind@utsjr.edu.mx

    2009-07-15

    Design, construction, and testing of the thermal performance of a flat solar collector for domestic water heating are described. The absorbing plate is built from readily available materials: two sheets of galvanized steel, one of the channelled types, the other one flat, which are joined by electric welding. The absorber is connected to a 198-L thermotank, insulated with polyurethane foam. In terms of receiving surface, the prototype tested here has an area of 1.35 m{sup 2}, about 20% smaller than comparable copper-tube-based collectors offered in the market. Temperature measurements conducted over a 30-day period gave values which were a few degrees lower than the theoretically calculated water temperatures. Momentary thermal efficiency values between 35% and 77% were observed. The water temperature achieved the tank at the end of the day averages 65 degrees Celsius in winter weather conditions in the central Mexican highland. This design of solar water heater is well suited to Mexican conditions, as it makes use of the high local intensity of the solar radiation, and as the channel shape of the ducts minimizes bursting during the rare occurrences of freezing temperatures in the region; it also has the advantage of being manufacturable at low cost from simple materials. [Spanish] Se describe el diseno, construccion y pruebas del desempeno termico de un colector solar plano para calentamiento de agua para uso domestico. La placa absorbedora se construyo de materiales facilmente asequibles: dos placas de acero galvanizado, una del tipo acanalado y la otra plana, unidas mediante soldadura de acero electrico. La placa absorbedora esta conectada a un termotanque con capacidad de 198 L, aislado con espuma de poliuretano. La superficie receptora de este prototipo es de 1.35 m{sup 2}, aproximadamente 20% mas pequena comparado con los colectores, basados en tubos de cobre, ofertados en el mercado. Mediciones de temperatura por un periodo de 30 dias, arrojaron valores

  10. HEAT TRANSFER PERFORMANCE OF AN OIL JET IMPINGING ON A DOWNWARD-FACING STAINLESS STEEL PLATE

    Directory of Open Access Journals (Sweden)

    Roy J Issa

    2011-01-01

    Full Text Available An experimental study is carried out for the quenching of a stainless steel plate using a single oil jet impinging on the bottom surface of the plate. The objective of this study is to investigate the effect of the oil jet flow operating conditions onto the heat transfer effectiveness when the plate is heated to temperatures ranging from around 115 to 630 oC, and the oil is heated to temperatures ranging from 60 to 75 oC. Tests are conducted on the oil at various temperatures to determine its viscosity. Experiments are conducted for nozzle exit flow rates ranging from 113 to 381 ml/min, oil jet pressures from 3.1 to 12 psi, and nozzle-to-plate surface distances of 0.6 and 1 cm. The variation of the oil heat flux and heat transfer coefficient with the surface temperature for the different quenching parameters is calculated from the acquired temperature data. Tests results show the oil heat transfer effectiveness keeps increasing for increasing plate temperature. Oil jet pressure is shown to have a considerable effect on the oil heat transfer, while the nozzle-to-plate surface distance is shown to have a lesser effect. The results of this study shall lead to a better understanding of the parameters that play an important role in oil quenching for applications that are of interest to the metal process industry.

  11. Role of plate-driven mantle flow in distribution of the global heat flow

    Institute of Scientific and Technical Information of China (English)

    叶正仁; 安镇文

    1999-01-01

    Heat flow in the Earth, from its hot interior to its relatively cool exterior, is the primary energy flow responsible for the dynamic nature of our planet. The motion of the plates excites a forced convective motion in the mantle, and this plate-driven mantle flow will strongly modulate the temperature field in the mantle because of the relatively high Peeler number of the mantle dynamic system. Here the role of the plate-driven mantle flow in the observed global heat flow is examined. The result reveals that the main feature of the distribution of the observed heat flow at the surface of the Earth matches well with the prediction and nearly one half of the average heat flow can be attributed to the thermal effect of the plate-driven mantle flow.

  12. Viscous dissipation effects on heat transfer in flow past a continuous moving plate

    Digital Repository Service at National Institute of Oceanography (India)

    Soundalgekar, V.M.; Murty, T.V.R.

    The study of thermal boundary layer on taking into account the viscous dissipative heat, on a continuously moving semi-infinite flat plate is presented here.Similarity solutions are derived and the resulting equations are integrated numerically...

  13. Long-term weathering effects on the thermal performance of the Libbey-Owens-Ford (liquid) solar collector

    Science.gov (United States)

    1979-01-01

    Thermal performance tests were conducted on the Libbey-Owens-Ford liquid collector, following long term exposure to natural weathering conditions. Visual inspection of the collector, prior to the retest, indicated noticeable clouding of the inner cover glass, probably resulting from outgassing of the insulation. The absorber plate also showed some discoloration. The test results indicated that performance degradation had occurred at inlet temperatures significantly above ambient. The change in the slope of the efficiency curve, from the original data, is a direct indicator of an increase in the collector heat loss coefficient.

  14. Hybrid Photovoltaic Thermal (PV/T Air and Water Based Solar Collectors Suitable for Building Integrated Applications

    Directory of Open Access Journals (Sweden)

    Adnan Ibrahim

    2009-01-01

    Full Text Available Problem statement: Experiments have been conducted to investigate the effect of mass flow rates on the electrical, thermal and combined of photovoltaic thermal efficiencies of the hybrid collectors. Approach: Two photovoltaic thermal solar collectors were designed and fabricated. The first collector, known as spiral flow absorber collector, designed to generate hot water and electricity. The second collector, known as single pass rectangular tunnel absorber collector designed to generate hot air and electricity. Both absorber collectors were fixed underneath the flat plate single glazing sheet of polycrystalline silicon PV module. Water was used as a heat transfer medium in spiral flow absorber collector and air for the Single pass rectangular tunnel absorber collector respectively. Results: The experiment results showed that the single flow absorber collector generates combined PV/T efficiency of 64%, electrical efficiency of 11% and power maximum achieved at 25.35 W. Moreover, Single pass rectangular tunnel absorber collector generated combined PV/T efficiency of 55%, electrical efficiency of 10% and maximum power of 22.45 W. Conclusion/Recommendations: The best mass flow rate achieved for spiral flow absorber collector is 0.011 kg sec-1 at surface temperature of 55% and 0.0754 kg sec-1 at surface temperature of 39°C for single pass rectangular collector absorber. It was recommended for PV/T system to further improve its efficiency by optimizing the contact surfaces between the solar panel (photovoltaic module and the tubes underneath and also recommended to use other type of photovoltaic cell such as amorphous silicon cell that posses the black mat surfaces property that will improve it thermal absorption.

  15. Performance Evaluation of a Nanofluid-Based Direct Absorption Solar Collector with Parabolic Trough Concentrator.

    Science.gov (United States)

    Xu, Guoying; Chen, Wei; Deng, Shiming; Zhang, Xiaosong; Zhao, Sainan

    2015-12-04

    Application of solar collectors for hot water supply, space heating, and cooling plays a significant role in reducing building energy consumption. For conventional solar collectors, solar radiation is absorbed by spectral selective coating on the collectors' tube/plate wall. The poor durability of the coating can lead to an increased manufacturing cost and unreliability for a solar collector operated at a higher temperature. Therefore, a novel nanofluid-based direct absorption solar collector (NDASC) employing uncoated collector tubes has been proposed, and its operating characteristics for medium-temperature solar collection were theoretically and experimentally studied in this paper. CuO/oil nanofluid was prepared and used as working fluid of the NDASC. The heat-transfer mechanism of the NDASC with parabolic trough concentrator was theoretically evaluated and compared with a conventional indirect absorption solar collector (IASC). The theoretical analysis results suggested that the fluid's temperature distribution in the NDASC was much more uniform than that in the IASC, and an enhanced collection efficiency could be achieved for the NDASC operated within a preferred working temperature range. To demonstrate the feasibility of the proposed NDASC, experimental performances of an NDASC and an IASC with the same parabolic trough concentrator were furthermore evaluated and comparatively discussed.

  16. Simulation Studies on A Cross Flow Plate Fin Heat Exchanger

    OpenAIRE

    Thirumarimurugan, M.; Kannadasan, T.; E. Ramasamy

    2008-01-01

    Compact heat exchangers which were initially developed for the aerospace industries in the1940s have been considerably improved in the past few years. The main reasons for the goodperformance of compact heat exchangers are their special design which includes turbulent which inturn use high heat transfer coefficient and resists fouling, and maximum temperature driving forcebetween the hot and cold fluids. Numerous types use special enhancement techniques to achieve therequired heat transfer in...

  17. Performing multiobjective optimization on perforated plate matrix heat exchanger surfaces using genetic algorithm

    Directory of Open Access Journals (Sweden)

    John Anish K.

    2017-01-01

    Full Text Available Matrix Heat Exchanger is having wide spread applications in cryogenics and aerospace, where high effectiveness and compactness is essential. This can be achieved by providing high thermal conductive plates and low thermal conductive spacers alternately. These perforated plate matrix heat exchangers have near to 100% efficiency due to low longitudinal heat transfer. The heat transfer and flow friction characteristics of a perforated plate matrix heat exchanger can be represented using Colburn factor and friction factor. In this paper, dimensionless parameters like Reynolds number (Re, porosity (p, perforation perimeter factor (P f, plate thickness to pore diameter ratio (l/d and spacer thickness to plate thickness ratio (s/l have been optimized for maximum Colburn factor and minimum friction factor using genetic algorithm. Two algorithms, one for single objective and the other for multi-objective problems, which are believed to be more efficient, are described. The algorithms coded with MATLAB, is used to perform multi-objective optimization on perforated plate matrix heat exchanger surfaces. The results show promising results.

  18. Simulation and Experimental Investigation of Thermal Performance of a Miniature Flat Plate Heat Pipe

    Directory of Open Access Journals (Sweden)

    R. Boukhanouf

    2013-01-01

    Full Text Available This paper presents the results of a CFD analysis and experimental tests of two identical miniature flat plate heat pipes (FPHP using sintered and screen mesh wicks and a comparative analysis and measurement of two solid copper base plates 1 mm and 3 mm thick. It was shown that the design of the miniature FPHP with sintered wick would achieve the specific temperature gradients threshold for heat dissipation rates of up to 80 W. The experimental results also revealed that for localised heat sources of up to 40 W, a solid copper base plate 3 mm thick would have comparable heat transfer performances to that of the sintered wick FPHP. In addition, a marginal effect on the thermal performance of the sintered wick FPHP was recorded when its orientation was held at 0°, 90°, and 180° and for heat dissipation rates ranging from 0 to 100 W.

  19. Radiative and free-convective heat transfer from a finite horizontal plate inside an enclosure

    Science.gov (United States)

    Hrycak, Peter; Sandman, D. J.

    1986-01-01

    An experimental and analytical investigation of heat transfer from a horizontal, thin, square plate inside of an enclosure was carried out. Experimental results were obtained from both the upward-facing and the downward-facing sides of the heated plate. Starting with the integrated momentum and energy equations, approximate solutions were obtained for heat transfer in the laminar and the turbulent regime that correlate well with experimental data. Radiative heat transfer correction was given special attention. Effects of the enclosure-related recirculation of the test fluid, as well as effects of simultaneous heat transfer on both sides of the plate, caused an early transition, and indicated a high level of internal turbulence.

  20. CFD SIMULATION OF THE HEAT TRANSFER PROCESS IN A CHEVRON PLATE HEAT EXCHANGER USING THE SST TURBULENCE MODEL

    Directory of Open Access Journals (Sweden)

    Jan Skočilas

    2015-08-01

    Full Text Available This paper deals with a computational fluid dynamics (CFD simulation of the heat transfer process during turbulent hot water flow between two chevron plates in a plate heat exchanger. A three-dimensional model with the simplified geometry of two cross-corrugated channels provided by chevron plates, taking into account the inlet and outlet ports, has been designed for the numerical study. The numerical model was based on the shear-stress transport (SST k-! model. The basic characteristics of the heat exchanger, as values of heat transfer coefficient and pressure drop, have been investigated. A comparative analysis of analytical calculation results, based on experimental data obtained from literature, and of the results obtained by numerical simulation, has been carried out. The coefficients and the exponents in the design equations for the considered plates have been arranged by using simulation results. The influence on the main flow parameters of the corrugation inclination angle relative to the flow direction has been taken into account. An analysis of the temperature distribution across the plates has been carried out, and it has shown the presence of zones with higher heat losses and low fluid flow intensity.

  1. Second law analysis of a plate heat exchanger with an axial dispersive wave

    Science.gov (United States)

    Kumar Das, Sarit; Roetzel, Wilfried

    A second law analysis is presented for thermally dispersive flow through a plate heat exchanger. It is well known that in plate or plate fin type heat exchangers the backmixing and other deviations from plug flow contribute significantly to the inefficiency of the heat exchanger, which is of importance to heat exchangers working in the cryogenic regime. The conventional axial heat dispersion model which is used so far is found to be better than `plug flow' model but still unsatisfactory where the timescale related to heat transfer is comparable with the thermal relaxation time for the propagation of dispersion. The present work therefore considers dispersion as a wave phenomenon propagating with a finite velocity. The study discusses the nature of variation of different contributions to total exergy loss in the heat exchanger with respect to dispersion parameters of the Peclet number and propagation velocity of the dispersive wave. The practical example of the single-pass plate heat exchanger demonstrates how a second law optimization can be carried out for heat transfer equipment under such conditions.

  2. Thermal Stresses in an Anisotropic Thin Plate Subjected to Moving Plane Heat Sources

    Directory of Open Access Journals (Sweden)

    Malak Naji

    2014-04-01

    Full Text Available The aim of this study is to numerically simulate the plane moving heat source through anisotropic mild steal thin plate. Heat conduction problems in anisotropic material, where the thermal conductivity varies with direction and involving a moving heat source have several industrial applications, such like metal cutting, flame or laser hardening of metals, welding and others. The parabolic heat conduction model is used for the prediction of the temperature history. The temperature distribution inside the plate is determined from the solution of heat equation. Thus, the heat equation is solved numerically using finite deference method and the temperature distributions are determined. The thermal stresses in this case are, also, investigated and computed numerically. It is found that the thermal conductivity ratio affect in both temperature and thermal stresses distributions, in additional to the speed and heat source intensity.

  3. Characteristic of Local Boiling Heat Transfer of Ammonia / Water Binary Mixture on the Plate Type Evaporator

    Science.gov (United States)

    Okamoto, Akio; Arima, Hirofumi; Kim, Jeong-Hun; Akiyama, Hirokuni; Ikegami, Yasuyuki; Monde, Masanori

    Ocean thermal energy conversion (OTEC) and discharged thermal energy conversion (DTEC) are expected to be the next generation energy production systems. Both systems use a plate type evaporator, and ammonia or ammonia/water mixture as a working fluid. It is important to clarify heat transfer characteristic for designing efficient power generation systems. Measurements of local boiling heat transfer coefficients and visualization were performed for ammonia /water mixture (z = 0.9) on a vertical flat plate heat exchanger in a range of mass flux (7.5 - 15 kg/m2s), heat flux (15 - 23 kW/m2), and pressure (0.7 - 0.9 MPa). The result shows that in the case of ammonia /water mixture, the local heat transfer coefficients increase with an increase of vapor quality and mass flux, and decrease with an increase of heat flux, and the influence of the flow pattern on the local heat transfer coefficient is observed.

  4. New Configurations of Micro Plate-Fin Heat Sink to Reduce Coolant Pumping Power

    DEFF Research Database (Denmark)

    Kolaei, Alireza Rezania; Rosendahl, Lasse

    2012-01-01

    The thermal resistance of heat exchangers has a strong influence on the electric power produced by a thermoelectric generator (TEG). In this work, a real TEG device is applied to three configurations of micro plate-fin heat sink. The distance between certain microchannels is varied to find...... the optimum heat sink configuration. The particular focus of this study is to reduce the coolant mass flow rate by considering the thermal resistances of the heat sinks and, thereby, to reduce the coolant pumping power in the system. The threedimensional governing equations for the fluid flow and the heat...... heat sink configurations reduces the coolant pumping power in the system....

  5. Solar heating system at Security State Bank, Starkville, Mississippi

    Science.gov (United States)

    1980-01-01

    The 312 square feet of Solaron flat plate air collectors provide for 788 square feet of space heating, an estimated 55 percent of the heating load. Solar heated air is distributed to the 96 cubic foot steel cylinder, which contains two inch diameter rocks. An air handler unit moves the air over the collector and into the steel cylinder. Four motorized dampers and two gravity dampers are also part of the system. A Solaron controller which has sensors located at the collectors, rock storage, and at the return air, automatically controls the system. Auxiliary heating energy is provided by electric resistance duct heaters.

  6. Natural Convection Heat Transfer From a Hot Rectangular and a Square Corrugated Plate to a Cold Flat Plate

    Institute of Scientific and Technical Information of China (English)

    M.A.R.Akhanda

    2000-01-01

    Experimental study of natural convection heat transfer across air layers bounded by a lower hot rectangular and a square corrugated plates to an upper cold flat plate has been carried out.The surroundings of this space are adiabatic.The effect of the angle of inclination,the aspect ratio,the temperature potential and the Rayleigh number on average heat transfer coefficients are investigated within a range of 0°≤θ≤75°,2.33≤A≤6.33,10°≤ΔT≤35°,and 3.29×104≤RaL≤2.29×106,The developed correlation predicts well the experimental data within an error of ±15%.

  7. Atomistic-Continuum Hybrid Simulation of Heat Transfer between Argon Flow and Copper Plates

    CERN Document Server

    Mao, Yijin; Chen, C L

    2016-01-01

    A simulation work aiming to study heat transfer coefficient between argon fluid flow and copper plate is carried out based on atomistic-continuum hybrid method. Navier-Stokes equations for continuum domain are solved through the Pressure Implicit with Splitting of Operators (PISO) algorithm, and the atom evolution in molecular domain is solved through the Verlet algorithm. The solver is validated by solving Couette flow and heat conduction problems. With both momentum and energy coupling method applied, simulations on convection of argon flows between two parallel plates are performed. The top plate is kept as a constant velocity and has higher temperature, while the lower one, which is modeled with FCC copper lattices, is also fixed but has lower temperature. It is found that, heat transfer between argon fluid flow and copper plate in this situation is much higher than that at macroscopic when the flow is fully developed.

  8. A dynamic model of an innovative high-temperature solar heating and cooling system

    OpenAIRE

    Buonomano Annamaria; Calise Francesco; Vicidomini Maria

    2016-01-01

    In this paper a new simulation model of a novel solar heating and cooling system based on innovative high temperature flat plate evacuated solar thermal collector is presented. The system configuration includes: flat-plate evacuated solar collectors, a double-stage LiBr-H2O absorption chiller, gas-fired auxiliary heater, a closed loop cooling tower, pumps, heat exchangers, storage tanks, valves, mixers and controllers. The novelty of this study lies in the ...

  9. Investigations on efficiencies of HT solar collectors for different flow rates and collector tilts

    DEFF Research Database (Denmark)

    Chen, Ziqian; Perers, Bengt; Furbo, Simon;

    2013-01-01

    Two HT solar collectors for solar heating plants from Arcon Solvarme A/S are tested in a laboratory test facility for solar collectors at Technical University of Denmark (DTU). The collectors are designed in the same way. However, one solar collector is equipped with an ETFE foil between...... the absorber and the cover glass and the other is without ETFE foil. The efficiencies for the collectors are tested at different flow rates and tilt. On the basis of the measured efficiencies, the efficiencies for the collectors as functions of flow rates are obtained. The calculated efficiencies are in good...... agreement with the measured efficiencies....

  10. Experimental results for hydrocarbon refrigerant vaporization inside brazed plate heat exchangers at high pressure

    DEFF Research Database (Denmark)

    Desideri, Adriano; Ommen, Torben Schmidt; Wronski, Jorrit;

    2016-01-01

    In recent years the interest in small capacity organic Rankine cycle (ORC) power systems for harvesting low qualitywaste thermal energy from industrial processes has been steadily growing. Micro ORC systems are normally equippedwith brazed plate heat exchangers which allows for efficient heat tra...

  11. The effect of blowing or suction on laminar free convective heat transfer on flat horizontal plates

    NARCIS (Netherlands)

    Brouwers, Jos

    1993-01-01

    In the present paper laminar free convective heat transfer on flat permeable horizontal plates is investigated. To assess the effect of surface suction or injection on heat transfer a correction factor, provided by the film model (or ldquofilm theoryrdquo), is applied. Comparing the film model predi

  12. Internal (Annular) and Compressible External (Flat Plate) Turbulent Flow Heat Transfer Correlations.

    Energy Technology Data Exchange (ETDEWEB)

    Dechant, Lawrence [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Smith, Justin [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-01-01

    Here we provide a discussion regarding the applicability of a family of traditional heat transfer correlation based models for several (unit level) heat transfer problems associated with flight heat transfer estimates and internal flow heat transfer associated with an experimental simulation design (Dobranich 2014). Variability between semi-empirical free-flight models suggests relative differences for heat transfer coefficients on the order of 10%, while the internal annular flow behavior is larger with differences on the order of 20%. We emphasize that these expressions are strictly valid only for the geometries they have been derived for e.g. the fully developed annular flow or simple external flow problems. Though, the application of flat plate skin friction estimate to cylindrical bodies is a traditional procedure to estimate skin friction and heat transfer, an over-prediction bias is often observed using these approximations for missile type bodies. As a correction for this over-estimate trend, we discuss a simple scaling reduction factor for flat plate turbulent skin friction and heat transfer solutions (correlations) applied to blunt bodies of revolution at zero angle of attack. The method estimates the ratio between axisymmetric and 2-d stagnation point heat transfer skin friction and Stanton number solution expressions for sub-turbulent Reynolds numbers %3C1x10 4 . This factor is assumed to also directly influence the flat plate results applied to the cylindrical portion of the flow and the flat plate correlations are modified by

  13. Displacement analysis of a bend plate test with mechanical loading and laser heating

    Energy Technology Data Exchange (ETDEWEB)

    Lam, P.S.

    1997-09-01

    The surface displacment of a steel plate caused by a permanent deformation as a result of local yielding was modeled by a finite element analysis. The local yielding occurs when a small area of the plate is heated by a laser beam. The calculated displacments are in good agreement with the preliminary experimental data obtained using a bend specimen with laser heating at the University of Alabama at Huntsville. It has been shown computuationally and optically that the relative displacments are less than 1mm near the laser heated area of the specimen. The results demonstrate that the experimental approach is a feasible technique for determining the residual stress under multiaxial stress field.

  14. Numerical Methods for Plate Forming by Line Heating

    DEFF Research Database (Denmark)

    Clausen, Henrik Bisgaard

    2000-01-01

    Few researchers have addressed so far the topic Line Heating in the search for better control of the process. Various methods to help understanding the mechanics have been used, including beam analysis approximation, equivalent force calculation and three-dimensional finite element analysis. I...... consider here finite element methods to model the behaviour and to predict the heating paths....

  15. Forced convection heat transfer of Couette-Poiseuille flow of nonlinear viscoelastic fluids between parallel plates

    Energy Technology Data Exchange (ETDEWEB)

    Hashemabadi, S.H. [Iran Univ. of Science and Technology, Dept. of Chemical Engineering, Tehran (Iran); Etemad, S.Gh. [Isfahan Univ. of Technology, Dept. of Chemical Engineering, Isfahan (Israel); Thibault, J. [Ottawa Univ., Dept. of Chemical Engineering, Ottawa, ON (Canada)

    2004-08-01

    Heat transfer to viscoelastic fluids is frequently encountered in various industrial processing. In this investigation an analytical solution was obtained to predict the fully developed, steady and laminar heat transfer of viscoelastic fluids between parallel plates. One of the plates was stationary and was subjected to a constant heat flux. The other plate moved with constant velocity and was insulated. The simplified Phan-Thien-Tanner (SPTT) model, believed to be a more realistic model for viscoelastic fluids, was used to represent the rheological behavior of the fluid. The energy equation was solved for a wide range of Brinkman number, dimensionless viscoelastic group, and dimensionless pressure drop. Results highlight the strong effects of these parameters on the heat transfer rate. (Author)

  16. Thermal Stresses in an Anisotropic Thin Plate Subjected to Moving Line Heat Sources

    Directory of Open Access Journals (Sweden)

    Malak Naji

    2014-02-01

    Full Text Available The aim of this present study is to investigate thermal stresses inside a thin anisotropic mild steal plate during moving line heat source. The parabolic heat conduction model is used for the prediction of the temperature history. The temperature distributions are determined numerically using finite difference method. Thermal stresses are computed numerically. It is found that the thermal conductivity ratio affect in both temperature and thermal stresses distributions, in additional to the speed and heat source intensity.

  17. Combined radiative and natural or forced convective heat transfer between parallel vertical plates with two-dimensional discrete heat sources

    Energy Technology Data Exchange (ETDEWEB)

    Nickell, T.W.

    1988-01-01

    This study numerically analyzes combined radiative and natural or forced convective heat transfer between vertical parallel plates with two-dimensional discrete heat sources. The numerical method was verified by comparing its results with other published experimental data and the agreement was excellent. It is shown that radiative heat transfer is a significant and useful mode of heat transfer in combination with both natural and forced convection in this situation and cannot be neglected. Radiative heat transfer accounted for 50-60% or more of the total heat transfer in some cases, and usually approximately 30-35% on the top of a discrete heat source. This fact can be used to advantage in the thermal design of electronic circuit boards.

  18. Parametric Influence on Thermal Performance of Flat Plate Closed Loop Pulsating Heat Pipes

    Institute of Scientific and Technical Information of China (English)

    YANG Hong-hai; KHANDEKAR Sameer; GROLL Manfred

    2006-01-01

    This paper presents an experimental study on a flat plate closed loop pulsating heat pipes. It consisted of total 40 channels with square cross section (2 × 2 mm2, 165 mm long) machined directly on an aluminum plate(180× 120×3mm3 ), which was covered by a transparent plate. The working fluid employed was ethanol. As the results, the influence parameters of thermal performance were investigated, such as filling ratio, heat load and operational orientations etc. Filling ratio was found to be a critical parameter, and its effect was rather complicated. According to its values the PHP plate could have four distinct working zones with different operational characteristics and heat transfer performance. The effect of heat load on thermal performance was found to be positive, and in general,increasing the heat load would improve heat transfer performance. In order to analyze the effect of gravity on thermal performance, three different heat modes and total seven tilt angles were tested and compared. Successful operation at all orientations with respect to gravity was also achieved.

  19. Effect of Liquid/Vapour Maldistribution on the Performance of Plate Heat Exchanger Evaporators

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Kærn, Martin Ryhl; Ommen, Torben Schmidt

    2015-01-01

    correlations for heat transfer and pressure drop. The flow distribution on both the refrigerant and secondary side is determined based on equal pressure drop while the liquid/vapour distribution is imposed to the model. Results show that maldistribution may cause up to a 25 % reduction of the overall heat...... transfer coefficient, compared to a lumped model with uniform distribution.......Plate heat exchangers are often applied as evaporators in industrial refrigeration and heat pump systems. In the design and modelling of such heat exchangers the flow and liquid/vapour distribution is often assumed to be ideal. However, maldistribution may occur and will cause each channel...

  20. Investigating the collector efficiency of silver nanofluids based direct absorption solar collectors

    OpenAIRE

    Chen, M.; He, Y.; J. Zhu; Wen, D

    2016-01-01

    A one-dimensional transient heat transfer analysis was carried out to analyze the effects of the Nanoparticle (NP) volume fraction, collector height, irradiation time, solar flux, and NP material on the collector efficiency. The numerical results were compared with the experimental results obtained by silver nanofluids to validate the model, and good agreement was obtained. The numerical results show that the collector efficiency increases as the collector height and NP volume fraction increa...

  1. Weathering of a liquid solar collector

    Science.gov (United States)

    1980-01-01

    Commercially available flate plate hot water solar collector is characterized in report that presents 10 month weathering study of system. Collector efficiency was calculated and plotted from measurements of fluid temperature and flow rate, ambient temperature and solar flux. Windspeed and wind direction were also measured during tests.

  2. Computer fluid dynamics (CFD) study of a plate heat exchanger working with nanofluids

    Science.gov (United States)

    Stan, Liviu-Constantin; Cǎlimǎnescu, Ioan

    2016-12-01

    The industry fosters many types of heat exchangers such double pipe or plate heat exchangers (HX), but lately the plate HX are gaining the high ground in many applications. Such a plate HX is made out of serial plate modules packed together allowing the warm and cold fluids to pass through and exchange the heat. The paper is demonstrating the functioning of a medium sized plate HX functioning with 10% Al2O3 and water nanofluids flowing in both cold and warm sides of the HX. The influence of the nanofluid properties will be investigated as impact upon the outlet temperature of the fluid leaving the HX. Using the RSM methodology. The main conclusion of this study is that there is a balance between the nanofluids increased conductivity and their increased viscosity. The nanofluids are working well for those applications where the flow is not impeded by narrow fluid passages where the bigger influence of the viscosity is actually worsening the heat transfer conditions instead of increasing it, since the influence of viscosity in that kind of applications is three time bigger. A nanofluid conductivity threshold was also detected over which the nanofluids say with 15$ or 20% alumina content is useless for the overall heat transfer conditions.

  3. Modelling of Microclimate in collectors

    DEFF Research Database (Denmark)

    Holck, Ole

    1996-01-01

    Abstract It is important to avoid condensation in solar collectors, most of all because wetness of the absorber can damage the selective surface and cause corrosion on the absorber plate. During night time the cover of collectors will cool below ambient temperature due to thermal radiation...... to the cold sky. In climates where the air during night time becomes saturated with humidity (the relative humidity is 100%), condensation will form on the outside and inside of the collector glazing. If too much condensation takes place on the inside of the glazing, it will start to fall off...... on to the absorber surface. It is important to characterize microclimatic conditions in the collector, and at the Department of Buildings and Energy work is carried out with the improvement of a computer model. As a tool the computer model will be useful in developing guidelines to achieve the most favourable...

  4. 主烟道内置式余热锅炉在邯钢加热炉上的应用%Application of waste heat boiler built-in flue collector in heating furnace of Han steel

    Institute of Scientific and Technical Information of China (English)

    武绍井; 吴斌; 李会朝

    2013-01-01

    The situation of application of waste heat boiler built -in flue collector in heating furnace of Han Iron and Steel was introduced .Actual running condition indicate that waste heat boiler installed in flue collector of hot rolling heating furnace can help reducing exhaust gas temperature and recovering waste heat, economic and social benefit is remarkable .It wills not effects regular production of the heating furnace depend on certain safety precautions .%介绍了主烟道内置式余热锅炉在邯宝钢铁有限公司热轧厂加热炉上的应用情况。实际运行情况表明,在轧钢加热炉主烟道内设置余热锅炉,可降低排烟温度,回收烟气余热,经济效益和社会效益显著。在采取一定安全措施后,不会对加热炉正常生产造成影响。

  5. 一种新型渗透式太阳能空气集热器的热性能研究%An Investigation on Heat Performance of a Novel Transpired Solar Air Collector

    Institute of Scientific and Technical Information of China (English)

    张欢; 高煜; 由世俊; 李宪莉

    2012-01-01

    设计制作了一种新型平板型、渗透式太阳能空气集热器,介绍了该集热器的结构、尺寸及工作原理,并以该集热器为研究对象,建立了数学模型,进行了实验测试.结果表明,在辐射水平较高且稳定、风速较小的测试条件下,该集热器的性能稳定,集热效率和出风温度较高,具有一定的推广与应用潜力;同时,所建数学模型准确可靠,可用来对集热器进行模拟分析.%A novel flat-plate and transpired solar air collector was designed and constructed, and the structure, size and working mechanism of the collector were introduced. Taking the collector as an object, the mathematical model was developed, and the experiment was carried out. Under the condition of high solar radiation intensity and low wind velocity, results show that the performance of the novel solar air collector is stable, and the output temperature and thermal efficiency are high enough to make the collector have a good prospect of popularization and application, and the mathematical model is accurate enough to analyze the novel solar air collector.

  6. Development of a Solar Assisted Drying System Using Double-Pass Solar Collector with Finned Absorber

    Science.gov (United States)

    Azmi, M. S. M.; Othman, M. Y.; Sopian, K.; Ruslan, M. H.; Majid, Z. A. A.; Fudholi, A.; Yasin, J. M.

    2012-09-01

    The Solar Energy Research Group, Universiti Kebangsaan Malaysia, International Islamic University Malaysia and Yayasan FELDA has designed and constructed a solar assisted drying system at OPF FELDA Factory, Felda Bukit Sagu 2, Kuantan, Pahang. The drying system has a total of six double-pass solar collectors. Each collector has a length of 480 cm and a width of 120 cm. The first channel depth is 3.5 cm and the second channel depth is 7 cm. Longitudinal fins made of angle aluminium, 0.8 mm thickness were attached to the bottom surface of the absorber plate. The solar collectors are arranged as two banks of three collectors each in series. Internal manifold are used to connect the collectors. Air enters through the first channel and then through the second channel of the collector. An auxiliary heater source is installed to supply heat under unfavourable solar radiation condition. An on/off controller is used to control the startup and shutdown of the auxiliary heater. An outlet temperature of 70-75 °C can be achieved at solar radiation range of 800-900 W/m2 and flow rate of 0.12 kg/s. The average thermal efficiency of a solar collector is approximately 37%.

  7. A solar energy collector

    Energy Technology Data Exchange (ETDEWEB)

    Vasilyev, L.L.; Avakyan, Yu V.; Dabagyan, T.N.; Grakovich, L.P.; Khustalev, D.K.; Morgun, V.A.; Vartanyan, A.V.

    1984-01-01

    During collector operation, solar emission is absorbed by the evaporator section of the heating tube; the degree of blackness of the forward wall of the section is increased significantly by the use of corrugations in this section. Boiling of the working fluid in the longitudinal slotted channels is accompanied by outbursts of the steam fluid mixture in the direction of the forward wall, resulting in wetting of the longitudinal corrugation on this wall. In this solar collector, there is a continuous flow of the working fluid onto the internal surface of the leading wall of the evaporation section of the heat tube; the working fluid evaporation process is accelerated by the spraying resulting from the popping of vapor bubbles.

  8. Investigations for effect of Al2O3–H2O nanofluid flow rate on the efficiency of direct absorption solar collector

    OpenAIRE

    Hemant Kumar Gupta; Ghanshyam Das Agrawal; Jyotirmay Mathur

    2015-01-01

    The efficiency of conventional tube‐ in plate type solar collectors is limited due to higher heat losses for surface based solar energy absorption and indirect transfer of heat from hot absorber surface to working fluid having poor heat transfer properties flowing through tubes. In this paper, a prototype direct absorption solar collector having gross area 1.4 m2 working on volumetric absorption principle is developed to investigate the effect of using Al2O3–H2O nanofluid as heat transfer flu...

  9. Numerical analysis of thermal deformation in laser beam heating of a steel plate

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Chao; Kim, Yong-Rae; Kim, Jae-Woong [Yeungnam University, Kyongsan (Korea, Republic of)

    2017-05-15

    Line heating is a widely used process for plate forming or thermal straightening. Flame heating and induction heating are the traditional heating processes used by industry for line heating. However, these two heating processes are ineffective when used on small steel plates. Thus, the laser beam heating with various power profiles were carried out in this study. A comparison of numerical simulation results and experimental results found a significant difference in the thermal deformation when apply a different power profile of laser beam heating. The one-sinusoid power profile produced largest thermal deformation in this study. The laser beam heating process was simulated by established a combined heat source model, and simulated results were compared with experimental results to confirm the model’s accuracy. The mechanism of thermal deformation was investigated and the effects of model parameters were studied intensively with the finite element method. Thermal deformation was found to have a significant relationship with the amount of central zone plastic deformation. Scientists and engineers could use this study’s verified model to select appropriate parameters in laser beam heating process. Moreover, by using the developed laser beam model, the analysis of welding residual stress or hardness could also be investigated from a power profile point of view.

  10. 基于微热管阵列的平板太阳能热水器的性能试验%Performance experiments for flat plate solar water heater based on micro heat pipe array

    Institute of Scientific and Technical Information of China (English)

    邓月超; 全贞花; 赵耀华; 王林成; 叶三宝

    2013-01-01

      为了检验一种新型平板太阳能热水器的性能,该文对其核心部件—基于微热管阵列的集热器及其组成的热水器进行了热性能试验.集热器热性能测试结果表明,微热管阵列平板太阳能集热器瞬时效率的斜率为4.7,截距为0.80,分别优于国家标准要求值11.0%和22.3%.在满足测试要求的天气情况下,对微热管阵列平板太阳能热水器进行的多次热性能测试结果表明,热水器的日有效得热量均高于国家标准要求值,日平均集热效率均高于60%.同时,该热水器具有承压能力强、无炸裂、轻巧、成本低、无需焊接、抗冻性能好、易于建筑一体化等优势.基于微热管阵列的平板太阳能热水器由于性能优异,并能克服现有太阳能热水器的缺点,具有广阔的应用前景.%A novel flat plate solar water heater based on the micro heat pipe array (MHPA) was invented, and the experiments were carried out on the MHPA heat collector and water heater to test their thermal performance. Owing to its distinctive structure, the MHPA has good heat transfer ability, high reliability, high compressive strength and low cost. The structure and character of the novel collector with MHPA as the high-efficiency heat transfer element are as follows. First, the contact surface between the absorber and the MHPA is so large that the heat resistance is smaller than the traditional one, thus its thermal transfer capability is greatly improved. Second, the condenser section of the MHPA is connected closely to the heat exchanger with dry type. The heat pipes do not contact with water, which precludes scaling and leakage in the collector. Third, the MHPA uses low freezing points of the refrigerants, which makes the collector more suitable for extremely cold areas. Fourth, the MHPA is made of aluminum instead of copper, which could reduce the fabrication cost significantly. Fifth, the unique heat exchanger could exclude water easily

  11. Derivation of guidelines for the design of plate evaporators in heat pumps using zeotropic mixtures

    DEFF Research Database (Denmark)

    Elmegaard, Brian; Mancini, Roberta; Zühlsdorf, Benjamin

    2017-01-01

    integration in a spray drying facility. A numerical model of the evaporator is combined with cycle calculations, for estimating the impact of heat transfer area and pressure drop on the coefficient of performance and costs. Common trends are obtained as optimal configurations for the four considered fluids...... minimization of area and pressure drop is found by assessing the relative impact on costs of the heat exchanger area and pressure losses of both working fluid and heat source. The result shows that it is not always convenient to minimize the heat transfer area, since the mixture pressure drop negatively......The present work derives design recommendations for plate heat exchangers used for evaporation of zeotropic mixtures in heat pumps. A parametric study is conducted on the geometry of the heat exchanger, and the analysis is carried out for four working fluids, based on a case study of heat pump...

  12. Technical and Economical Comparison of Plate, Shell and Tube and Miniature Pipe Type Heat Exchangers

    Directory of Open Access Journals (Sweden)

    Ahmet Serhan CANBOLAT

    2016-10-01

    Full Text Available Heat exchangers are devices which facilitate the exchange of heat between two fluids that are different temperatures in engineering applications. Heat exchangers are commonly used in practice in a wide range of applications such as space heating and air conditioning, power production, waste heat recovery and chemical processing engineering. In this study, plate, shell and tube and multiple mini-tube type heat exchangers for the same heat capacity, with the same hot and cold water inlet and outlet temperatures and the same hot and cold water mass flow rates are compared with the technical and economical point of view respectively. When the evaluation criteria is cost; multiple mini tube type heat exchanger is the most economic choise in comparison the other exchangers in long term. However, due to the different usage areas, different choices may be done.

  13. Concept for support and heating of plate-like samples in the ultra-high vacuum

    Science.gov (United States)

    Tröger, L.; Pieper, H. H.; Reichling, M.

    2013-01-01

    We present the concept for a sample holder designed for mounting and heating of plate-like samples that is based on a clamping mechanism for easy handling. The clamping mechanism consists of a U-shaped bracket encompassing the sample support plate from the rear. Two spring wires are fixed in the walls of the bracket spanning the sample to secure it with only two point contacts. This enables the sample to freely expand or contract during heating and cooling. To accommodate for a large variety in sample size, shape, and quality, we introduce two designs differing in the generation of the clamping force: One pressing the sample against the spring wires, the other one pulling the spring wires onto the sample. Both designs yield an automatically even alignment of the sample during the mounting process to achieve an even load distribution and reliable fixation specifically for brittle samples. For high temperature treatment, the sample holders are enhanced by a resistive heating plate. As only the sample and a small fraction of the sample holder are heated, temperatures of 1300 °C are reached with only 8 W heating power. The sample support and heating components are mounted on a 11 mm × 13 mm base plate with a handle that can be transferred between the sample entry stage, the preparation stage, and surface science experiments in the ultra-high vacuum system.

  14. Experimental Simulation of Natural Heat Convection from Finned Vertical Plate with Different Inclinations

    Directory of Open Access Journals (Sweden)

    Saad Najeeb Shehab

    2016-09-01

    Full Text Available In this work an experimental simulation is made to predict the performance of steady-state natural heat convection along heated finned vertical base plate to ambient air with different inclination angles and configurations of fin array. Two types of fin arrays namely vertical fins array and V-fins array on heated vertical base plate are used with different heights and spaces. The influence of inclination angle of the plate , configuration of fins array and fin geometrical parameters such as fin height and fin spacing on the temperature distribution, base convection heat transfer coefficient and average Nusselt number have been plotted and discussed. The experimental data are correlated to a formula between average Nusselt number versus Rayleigh number for vertical plate and vertical fins array. The results indicate that the configuration of V-fins array gave best natural-convection heat transfer performance as base heat transfer coefficient about 20% greater compared with vertical fins array. Experimental simulation data and correlations of the present work are compared with a previous works shows good agreement

  15. Neutral beam heating of the TFTR vacuum vessel protective plates

    Energy Technology Data Exchange (ETDEWEB)

    Sink, D.A.

    1976-04-01

    The transmission of neutral beams through plasmas expected in the Tokamak Fusion Test Reactor (TFTR) has been investigated. An analytical expression for the transmission coefficient of a 120 keV deuterium beam through a tritium plasma was used and a model for the flux profile of the TFTR Neutral Beam System designed by LBL/LLL was developed and incorporated. The plasma is assumed to have a parabolic profile and is characterized by a major radius of 310 cm, a minor radius of 57 cm, and a central plasma density of greater than or equal to 0.4 x 10/sup 14/ cm-/sup 3/. To protect the stainless steel vacuum vessel walls of the TFTR device, tungsten plates are located inside the vessel. The loading of the tungsten protective plates during normal operation is well below the neutral beam fluxes which would melt the tungsten. The TFTR Neutral Beam System will inject a total of 20 MW of 120 keV deuterium atoms from twelve sources, as well as approximately 12 MW of 60 keV deuterium atoms. The fluxes anticipated on the tungsten plates due to an unattenuated beam which would be incident at an angle of 45/sup 0/ are less than or equal to 6.5 kW/cm/sup 2/. The fluxes due to an attenuated beam are calculated to be less than or equal to 0.35 kW/cm/sup 2/. For the maximum injection time of 0.5 second, a fault condition in which the plasma was not formed at the time of injection could induce a surface temperature very near the melting point of tungsten. For the standard 0.1 second injection time anticipated for TFTR, a similar fault condition would not cause the temperature to rise to more than 2000 K which is well below the melting point (3640 K) of tungsten.

  16. Numerical Model on Frost Height of Round Plate Fin Used for Outdoor Heat Exchanger of Mobile Electric Heat Pumps

    Directory of Open Access Journals (Sweden)

    Moo-Yeon Lee

    2012-01-01

    Full Text Available The objective of this study is to provide the numerical model for prediction of the frost growth of the round plate fin for the purpose of using it as a round plate fin-tube heat exchanger (evaporator under frosting conditions. In this study, numerical model was considering the frost density change with time, and it showed better agreement with experimental data of Sahin (1994 than that of the Kim model (2004 and the Jonse and Parker model (1975. This is because the prediction on the frost height with time was improved by using the frost thermal conductivity reflecting the void fraction and density of ice crystal with frost growth. Therefore, the developed numerical model could be used for frosting performance prediction of the round plate fin-tube heat exchanger.

  17. Conjugate heat transfer study of a turbulent slot jet impinging on a moving plate

    Science.gov (United States)

    Achari, A. Madhusudana; Das, Manab Kumar

    2017-03-01

    Numerical simulation of the flow field and conjugate heat transfer in an impinging jet with moving impingement plate is one of the important problems as it mimics closely with practical applications in industries. The Yang-Shih version of low Reynolds number k-ɛ model has been used to resolve the flow field and the temperature field in a two-dimensional, steady, incompressible, confined, turbulent slot jet impinging normally on a moving flat plate of finite thickness. The turbulence intensity and the Reynolds number considered at the inlet are 2 % and 15,000, respectively. The bottom face of the impingement plate has been maintained at a constant temperature higher than the nozzle exit temperature. The confinement plate has been considered to be adiabatic. The nozzle-to-surface spacing for the above study has been taken to be 6 and the surface-to-jet velocity ratios have been taken over a range of 0.25-1. The effects of impingement plate motion on the flow field and temperature field have been discussed elaborately with reference to stationary impingement plate. The dependence of flow field and fluid temperature field on impingement plate motion has been analyzed by plotting streamlines, isotherms for different plate speeds. A thorough study of flow characteristics for different surface-to-jet velocity ratios has been carried out by plotting profiles of mean vertical and horizontal components of velocity, pressure distribution, local shear stress distribution. The isotherms in the impingement plate of finite thickness, the distributions of solid-fluid interface temperature, the local Nusselt number, and the local heat flux for different surface-to-jet velocity ratios added to the understanding of conjugate heat transfer phenomenon.

  18. Development of a micro-heat exchanger with stacked plates using LTCC technology

    Directory of Open Access Journals (Sweden)

    E. Vásquez-Alvarez

    2010-09-01

    Full Text Available A green ceramic tape micro-heat exchanger was developed using Low Temperature Co-fired Ceramics technology (LTCC. The device was designed by using Computational Aided Design software and simulations were made using a Computational Fluid Dynamics package (COMSOL Multiphysics to evaluate the homogeneity of fluid distribution in the microchannels. Four geometries were proposed and simulated in two and three dimensions to show that geometric details directly affect the distribution of velocity in the micro-heat exchanger channels. The simulation results were quite useful for the design of the microfluidic device. The micro-heat exchanger was then constructed using the LTCC technology and is composed of five thermal exchange plates in cross-flow arrangement and two connecting plates, with all plates stacked to form a device with external dimensions of 26 x 26 x 6 mm³.

  19. 平板太阳能集热器热性能数学建模及模拟%Mathematical Modeling and Simulation of Thermal Properties of Flat-Plate Solar Collector

    Institute of Scientific and Technical Information of China (English)

    卢郁; 于洪文; 丁海成; 张艳丽; 刘宗明

    2013-01-01

    以平板太阳能集热器作为研究对象,通过对平板太阳能集热器热性能进行理论推导,引入效率因子,构建更为准确、便捷的平板集热器的数学模型,进行计算机程序模拟.根据模拟数据得出吸热体板芯几何结构、板芯用材对平板太阳能集热器性能的影响.在不降低集热器效率因子的情况下,使翅片的单位面积质量降低45.8%;在材料消耗相同的情况下,集热器效率因子提高了0.03.%Taking a flat-plate solar collector as research object and introducing an efficiency factor, we establish a mathematical model for the collector after theoretically deriving out the thermal properties of it, and numerically simulate it according to this model. Simulation results show that the mass per unit area of the collector drops 45. 8% with the same efficiency factor and the efficiency factor increasesby 0.03 with the same material consumption.

  20. Performance Evaluation of a Nanofluid-Based Direct Absorption Solar Collector with Parabolic Trough Concentrator

    Directory of Open Access Journals (Sweden)

    Guoying Xu

    2015-12-01

    Full Text Available Application of solar collectors for hot water supply, space heating, and cooling plays a significant role in reducing building energy consumption. For conventional solar collectors, solar radiation is absorbed by spectral selective coating on the collectors’ tube/plate wall. The poor durability of the coating can lead to an increased manufacturing cost and unreliability for a solar collector operated at a higher temperature. Therefore, a novel nanofluid-based direct absorption solar collector (NDASC employing uncoated collector tubes has been proposed, and its operating characteristics for medium-temperature solar collection were theoretically and experimentally studied in this paper. CuO/oil nanofluid was prepared and used as working fluid of the NDASC. The heat-transfer mechanism of the NDASC with parabolic trough concentrator was theoretically evaluated and compared with a conventional indirect absorption solar collector (IASC. The theoretical analysis results suggested that the fluid’s temperature distribution in the NDASC was much more uniform than that in the IASC, and an enhanced collection efficiency could be achieved for the NDASC operated within a preferred working temperature range. To demonstrate the feasibility of the proposed NDASC, experimental performances of an NDASC and an IASC with the same parabolic trough concentrator were furthermore evaluated and comparatively discussed.

  1. Performance Evaluation of a Nanofluid-Based Direct Absorption Solar Collector with Parabolic Trough Concentrator

    Science.gov (United States)

    Xu, Guoying; Chen, Wei; Deng, Shiming; Zhang, Xiaosong; Zhao, Sainan

    2015-01-01

    Application of solar collectors for hot water supply, space heating, and cooling plays a significant role in reducing building energy consumption. For conventional solar collectors, solar radiation is absorbed by spectral selective coating on the collectors’ tube/plate wall. The poor durability of the coating can lead to an increased manufacturing cost and unreliability for a solar collector operated at a higher temperature. Therefore, a novel nanofluid-based direct absorption solar collector (NDASC) employing uncoated collector tubes has been proposed, and its operating characteristics for medium-temperature solar collection were theoretically and experimentally studied in this paper. CuO/oil nanofluid was prepared and used as working fluid of the NDASC. The heat-transfer mechanism of the NDASC with parabolic trough concentrator was theoretically evaluated and compared with a conventional indirect absorption solar collector (IASC). The theoretical analysis results suggested that the fluid’s temperature distribution in the NDASC was much more uniform than that in the IASC, and an enhanced collection efficiency could be achieved for the NDASC operated within a preferred working temperature range. To demonstrate the feasibility of the proposed NDASC, experimental performances of an NDASC and an IASC with the same parabolic trough concentrator were furthermore evaluated and comparatively discussed. PMID:28347112

  2. Investigation of CaCO3 fouling in plate heat exchangers

    Science.gov (United States)

    Li, Wei; Zhou, Kan; Manglik, Raj M.; Li, Guan-Qiu; Bergles, Arthur E.

    2016-11-01

    An experimental investigation, coupled with theoretical modeling of CaCO3 fouling in plate-and-frame type heat exchangers (PHEs) have been conducted. Four different plates, made of SS-304, are used in two different surface patterns (chevron and zig-zag) of varying corrugation severity (waviness depth and pitch) and area enhancement. They were further characterized in clean, non-fouled convection by their measured heat transfer coefficients and friction factors in the Reynolds number range of 600-6000. The flow-fouling experiments delineate the effects of temperature and plate-surface geometry on growth rates and stabilization of fouling resistance, along with the anti-fouling behavior of plates coated with a hydrophobic PTFE (Teflon) film. Moreover, the microscopic structure of fouling deposits is mapped in a scanning-electron microscope. Corrugated plates with the largest height-to-pitch ratio and hydraulic diameter are found to have the lowest fouling growth rate and resistance; Teflon-film coating of plate surface is also found to mitigate fouling relative to the performance of bare stainless steel plates. Finally, a semi-empirical fouling model, based on the Prandtl-Taylor analogy, has been devised to describe the experimental data and provide a predictive tool.

  3. Intermittent duty solar refrigerator assisted by heat pipes

    Energy Technology Data Exchange (ETDEWEB)

    Al-Hindi, R.R.; Khalifa, A.M.A.; Akyurt, M.

    1988-01-01

    The design of a solar operated intermittent-duty aqua-ammonia type of absorption refrigerator is described. The generator is heated by an integral acetone heat pipe, the evaporator of which is in the form of a low-thermal-mass flat plate collector. The condenser is air cooled. The absorber is likewise cooled via a second R22 heat-pipe system by convection/radiation panels. Initial test results for the collector-generator loop are reported for a single-glazed collector. A discussion of overall performance is presented.

  4. Solar Thermal Radiant Heating at Pohakuloa Training Area

    Science.gov (United States)

    2010-06-01

    Solar collector panels. • Sizing the array: Using thermal storage of 256,000 BTU/day and 4’ x 10’ flat panel collectors with output of...be arranged side-by-side on the south- facing pitch of roof. – Racked at 30 angle to maximize winter sun. Flat plate solar collectors E2S2– June 2010...radiant heat flooring project will combine solar thermal hot water system with in-floor radiant heating. – Flooring heat only; no domestic water. – Flat

  5. Solar thermal collectors using planar reflector

    Science.gov (United States)

    Espy, P. N.

    1978-01-01

    Specular reflectors have been used successfully with flat-plate collectors to achieve exceptionally high operating temperatures and high delivered energy per unit collector area. Optimal orientation of collectors and reflectors can result in even higher performance with an improved relationship between energy demand and supply. This paper reports on a study providing first order optimization of collector-reflector arrays in which single- and multiple-faceted reflectors in fixed or singly adjustable configurations provide delivered energy maxima in either summer or winter.

  6. Experimental investigations and validation of two dimensional model for multistream plate fin heat exchangers

    Science.gov (United States)

    Goyal, Mukesh; Chakravarty, Anindya; Atrey, M. D.

    2017-03-01

    Experimental investigations are carried out using a specially developed three-layer plate fin heat exchanger (PFHE), with helium as the working fluid cooled to cryogenic temperatures using liquid nitrogen (LN2) as a coolant. These results are used for validation of an already proposed and reported numerical model based on finite volume analysis for multistream (MS) plate fin heat exchangers (PFHE) for cryogenic applications (Goyal et al., 2014). The results from the experiments are presented and a reasonable agreement is observed with the already reported numerical model.

  7. Heat transfer from impinging jets to a flat plate with conical and ring protuberances

    Science.gov (United States)

    Hrycak, P.

    1984-01-01

    An experimental investigation of heat transfer from round jets, impinging normally on a flat plate with exchangeable, heat transfer enhancing protuberances, has been carried out, and the pertinent literature surveyed, for Reynolds numbers ranging from 14,000 to 67,000, and nozzle diameters from 3.18 to 9.52 mm. The experimental data at the stagnation point indicated laminar flow, and a significant enhancement of heat transfer there, due to the introduction of the spike protuberance; the ring protuberance reduced the local heat flux somewhat. Data have also been correlated by means of dimensional analysis and compared with the conical flow theory.

  8. Using the heat flow plate method for determining thermal conductivity of building materials

    Science.gov (United States)

    Flori, M.; Puţan, V.; Vîlceanu, L.

    2017-01-01

    The heat flow plate method is used to determine thermal conductivity of a building material sample made of Rohacell (insulating foam). Experimental technique consists in placing the sample with a reference material on top (polystyrene sample) in a calorimetric chamber and heating from underside. Considering that the heat flux which passes through the two layers is constant and knowing thermal conductivity of the reference material, the sample thermal conductivity is determined. The temperature difference between the two opposite sample’s sides is recorded only when the steady state is achieved (constant heat flux).

  9. MINICHANNEL-TUBE SOLAR THERMAL COLLECTORS FOR LOW TO MEDIUM TEMPERATURE APPLICATIONS

    OpenAIRE

    Duong, Thuc

    2015-01-01

    Novel minichannel-tube solar thermal collectors for low to medium temperature applications are introduced. Two types of minichannel solar thermal collectors are analyzed experimentally: aluminum minichannel solar collector for low temperature applications, and copper minichannel solar collector for low to medium temperature applications.The aluminum minichannel solar collector has been tested for over a year alongside a conventional copper flat-plate solar collector of similar dimensions as t...

  10. Development of a Resistive Plate Chamber with heat strengthened glass

    Science.gov (United States)

    Majumder, G.; Datar, V. M.; Kalmani, S. D.; Mondal, N. K.; Mondal, S.; Satyanarayana, B.; Shinde, R. R.

    2016-09-01

    The INO-ICAL is a proposed neutrino physics experiment, in which RPCs will be used as active detectors. The Iron Calorimeter (ICAL) detector will be made of 50 kTon of low carbon magnetized steel layers, tiled with 4 m × 2 m × 56 mm thick plates, alternating with layers of RPCs. The total number of 2 × 2 m2 RPCs required will be about 29000. However, during the assembly of RPCs, handling the 2 × 2 m2 normal float glass of thickness 3 mm is both difficult and risky. This prompted us to make RPCs with toughened glass and to characterize them. Toughened and tempered glass have higher mechanical strength compared to normal float glass and their processing involves controlled thermal or chemical treatment during the industrial production. This paper presents a comparison of the characteristics, such as noise rate, dark current, particle detection efficiency and time resolution, of normal and hardened glass RPCs.

  11. Standardized performance tests of collectors of solar thermal energy: A selectively coated, steel collector with one transparent cover

    Science.gov (United States)

    1976-01-01

    Basic test results are presented of a flat-plate solar collector whose performance was determined in solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and coolant flow rates. Collector efficiency was correlated in terms of inlet temperature and flux level.

  12. Standardized performance tests of collectors of solar thermal energy: An evacuated flatplate copper collector with a serpentine flow distribution

    Science.gov (United States)

    Johnson, S. M.

    1976-01-01

    Basic test results are given for a flat plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and one coolant flow rate. Collector efficiency is correlated in terms of inlet temperature and flux level.

  13. CFD analysis of the plate heat exchanger - Mathematical modelling of mass and heat transfer in serial connection with tubular heat exchanger

    Science.gov (United States)

    Bojko, Marian; Kocich, Radim

    2016-06-01

    Application of numerical simulations based on the CFD calculation when the mass and heat transfer between the fluid flows is essential component of thermal calculation. In this article the mathematical model of the heat exchanger is defined, which is subsequently applied to the plate heat exchanger, which is connected in series with the other heat exchanger (tubular heat exchanger). The present contribution deals with the possibility to use the waste heat of the flue gas produced by small micro turbine. Inlet boundary conditions to the mathematical model of the plate heat exchanger are obtained from the results of numerical simulation of the tubular heat exchanger. Required parameters such for example inlet temperature was evaluated from temperature field, which was subsequently imported to the inlet boundary condition to the simulation of plate heat exchanger. From the results of 3D numerical simulations are evaluated basic flow variables including the evaluation of dimensionless parameters such as Colburn j-factor and friction ft factor. Numerical simulation is realized by software ANSYS Fluent15.0.

  14. Performance Evaluation of Plate-Fin-And Tube Heat Exchanger with Wavy Fins- A Review

    Directory of Open Access Journals (Sweden)

    Sandip S. Kale

    2014-09-01

    Full Text Available The plate fin-and-tube heat exchangers are widely used in variety of industrial applications, particularly in the heating, air-conditioning and refrigeration, HVAC industries. In most cases the working fluid is liquid on the tube side exchanging heat with a gas, usually air. It is seen that the performance of heat exchangers can be greatly increased with the use of unconventionally shaped flow passages such as plain, perforated offset strip, louvered, wavy, vortex generator and pin. The current study is focused on wavy-fin. The wavy surface can lengthen the path of airflow and cause better airflow mixing. In order to design better heat exchangers and come up with efficient designs, a thorough understanding of the flow of air in these channels is required. Hence this study focuses on the heat transfer and friction characteristics of the air side for wavy fin and tube heat exchanger.

  15. The use of collector efficiency test results in long term performance calculations. Revisions and clarifications in view of proper collector characterization and inter comparison

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Maria Joao; Horta, Pedro; Mendes, Joao Farinha [INETI - Inst. Nacional de Engenharia Tecnologia e Inovacao, IP, Lisboa (Portugal); Collares Pereira, Manuel; Carbajal, Wildor Maldonado [AO SOL, Energias Renovaveis, S.A., Samora Correia (Portugal)

    2008-07-01

    There are a growing number of solar thermal collector types: flat plates, evacuated tubes with and without backing reflectors and different tubular spacing, low concentration collectors, using different types of concentrating optics. These different concepts and designs all compete to be more efficient or simply cheaper, easier to operate, etc. at ever higher temperatures, and even to extend the use of solar thermal energy in other applications beyond the most common water heating for domestic purposes. This means that there is a growing need for the existing and future simulation tools to be as accurate as possible in the treatment of these different collector types, to allow for the proper dimensioning of solar thermal systems as well as the proper comparison of different collector technologies for a given application. This paper develops a systematic approach to the problem of the proper handling of solar radiation available to each collector type. The proposed methodology subdivides radiation in its different components, folding that with the information available from efficiency curve tests (steady state) for each collector type and the way the optics of each particular case transforms and uses the incident solar radiation. The suggestions made will hopefully be taken at the level of the testing standards themselves, rendering them more complete and general. (orig.)

  16. Winter performance of a domestic solar-heating system--Duffield, Virginia

    Science.gov (United States)

    1981-01-01

    Sunlight supplies 39 percent of heat load, saving 9 barrels of fuel oil in one heating season. Report describes system installation in two-story, single-family residence. Energy is collected with roof-mounted air flat-plate collectors, stored in rock bin, and transferred to water preheat tank whenever system is storing energy; heat pump supplies heat to house.

  17. The influence of flow maldistribution on the performance of inhomogeneous parallel plate heat exhangers

    DEFF Research Database (Denmark)

    Nielsen, Kaspar Kirstein; Engelbrecht, Kurt; Bahl, Christian R.H.

    2013-01-01

    The heat transfer performance of inhomogeneous parallel plate heat exchangers in transient operation is investigated using an established model. A performance parameter, denoted the Nusselt-scaling factor, is used as benchmark and calculated using a well-established single blow technique. A sample...... of 50 random stacks having equal average channel thicknesses with 20 channels each are used to provide a statistical base. The standard deviation of the stacks is varied as are the flow rate (Reynolds number) and the thermal conductivity of the solid heat exchanger material. It is found that the heat...... transfer performance of inhomogeneous stacks of parallel plates may be reduced significantly due to the maldistribution of the fluid flow compared to the ideal homogeneous case. The individual channels experience different flow velocities and this further induces an inter-channel thermal cross talk....

  18. On the pressure drop in Plate Heat Exchangers used as desorbers in absorption chillers

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Hernando, N.; de Vega, M. [Energy System Engineering (ISE), Departamento de Ingenieria Termica y de Fluidos, Universidad Carlos III de Madrid, Avda. Universidad, 30, 28911 Leganes, Madrid (Spain); Almendros-Ibanez, J.A. [Escuela de Ingenieros Industriales de Albacete, Departamento de Mecanica Aplicada e Ingenieria de Proyectos, Universidad de Castilla La Mancha, Campus Universitario s/n, 02071 Albacete (Spain); Renewable Energy Research Institute, c/de la Investigacion s/n, 02071 Albacete (Spain); Ruiz, G. [Energy Efficiency and Renewables Department, Tecnicas Reunidas S.A., C/Arapiles No. 13, 10a, 28015 Madrid (Spain)

    2011-02-15

    The influence of the pressure drop in Plate Heat Exchangers (PHE) in the boiling temperature of LiBr-H{sub 2}O and NH{sub 3}-H{sub 2}O solutions is studied. For the NH{sub 3}-H{sub 2}O solution, the pressure drop-temperature saturation relationship estates that high pressure drops can be allowed in the solution with negligible changes in the saturation temperature, and in the PHE performance. Besides, in the case of the LiBr-H{sub 2}O solution, as the working pressure is usually very low, the analysis of the pressure drop must be taken as a main limiting parameter for the use of Plate Heat Exchangers as vapour generators. In this case, the pressure drop may considerably change the boiling temperature of the solution entering the heat exchanger and therefore a higher heating fluid temperature may be required. A guideline to design these systems is proposed. (author)

  19. Flat plate heat transfer for laminar transition and turbulent boundary layers using a shock tube

    Science.gov (United States)

    Brostmeyer, J. D.; Nagamatsu, H. T.

    1984-01-01

    Heat transfer results are presented for laminar, transition, and turbulent boundary layers for a Mach number of 0.12 with gas temperatures of 425 K and 1000 K over a flat plate at room temperature. The measurements were made in air for a Reynolds number range of 600 to 6 million. The heat transfer measurements were conducted in a 70-ft long, 4 in. diameter shock tube. Reflecting wedges were used to reflect the incident shock wave to produce a flow Mach number of 0.12 behind the reflected shock wave. Thin film platinum heat gages were mounted on the plate surface to measure the local heat flux. The laminar results for gas temperatures of 425 K to 1000 K agree well with theory. The turbulent results are also close to incompressible theory, with the 1000 K flow case being slightly higher. The transition results lie between the laminar and turbulent predictions.

  20. Experimental testing of various heat transfer structures in a flat plate thermal energy storage unit

    Science.gov (United States)

    Johnson, Maike; Fiß, Michael; Klemm, Torsten

    2016-05-01

    For solar process heat applications with steam as the working fluid and varying application parameters, a novel latent heat storage concept has been developed using an adaptation of a flat plate heat exchanger as the storage concept. Since the pressure level in these applications usually does not exceed 30 bar, an adaptation with storage material chambers arranged between heat transfer medium chambers is possible. Phase change materials are used as the storage medium, so that the isothermal evaporation of steam during discharging of the storage is paired with the isothermal solidification of the storage material. Heat transfer structures can be inserted into the chambers to adjust the power level for a given application. By combining the required number of flat plate heat exchanger compartments and inserting the appropriate heat transfer structure, the design can easily be adjusted for the required power level and capacity for a specific application. Within this work, the technical feasibility of this concept is proven. The dependence of the operating characteristics on the geometry of the heat exchanger is identified. A focus is on varying the power density by integrating conductive heat structures in the PCM.

  1. Validation of a simple dynamic thermal performance characterization model based on the piston flow concept for flat-plate solar collectors

    DEFF Research Database (Denmark)

    Deng, Jie; Yang, Ming; Ma, Rongjiang

    2016-01-01

    dynamic model based on the first-order difference method is compared to that of the numerical solution of the collector ordinary differential equation (ODE) model using the fourth-order Runge-Kutta method. The improved thermal inertia model (TIM) on the basis of closed-form solution presented by Deng et...

  2. Homotopy perturbation method for heat transfer flow of a third grade fluid between parallel plates

    Energy Technology Data Exchange (ETDEWEB)

    Siddiqui, A.M. [Pennsylvania State University, York Campus, York, PA 17403 (United States); Zeb, A. [COMSATS Institute of Information Technology, 30 H-8/1, Islamabad (Pakistan)], E-mail: amtaz56@yahoo.co.uk; Ghori, Q.K. [COMSATS Institute of Information Technology, 30 H-8/1, Islamabad (Pakistan); Benharbit, A.M. [Pennsylvania State University, York Campus, York, PA 17403 (United States)

    2008-04-15

    The present paper studies the heat transfer flow of a third grade fluid between two heated parallel plates for the constant viscosity model. Three flow problems, namely plane Couette flow, plane Poiseuille flow and plane Couette-Poiseuille flow have been considered. In each case the non-linear momentum equation and the energy equation have been solved using the homotopy perturbation method. Explicit analytical expressions for the velocity field and the temperature distribution have been derived.

  3. Skin friction and heat transfer of liquid jet over a continuous moving horizontal hot plate

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The skin friction and heat transfer occurring in the laminarboundary layer which caused by a vertical liquid jet impinging on a continuously moving horizontal plate were studied. Similarity solutionsfor shear stress and heat distribution were obtained by using the shooting technique. The results shows that the skin friction decreases with an increase of velocity parameter, the evolving of thermal boundarydecrease with increasing in Prandtl number, but increase with increasing of velocity parameter.

  4. Numerical Evaluation of Flow and Heat Transfer in Plate-Pin Fin Heat Sinks with Various Pin Cross-Sections

    OpenAIRE

    Zhou, Feng; Catton, Ivan

    2011-01-01

    A numerical investigation of the thermal and hydraulic performance of twenty different plate-pin fin heat sinks with various shapes of pin cross-section (square, circular, elliptic, NACA profile and dropform) and different ratios of pin widths to plate fin spacing (0.3, 0.4, 0.5 and 0.6) was performed. Finite Volume Method based CFD software, Ansys CFX, was used as the 3-D Reynolds-averaged Navier-Stokes Solver. A k-ω based Shear-Stress-Transport model was used to predict the turbulent flow a...

  5. Plate Fin Heat Exchanger Model with Axial Conduction and Variable Properties

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, B.J.; White, M.J.; Klebaner, A.; /Fermilab

    2011-06-10

    Future superconducting radio frequency (SRF) cavities, as part of Project X at Fermilab, will be cooled to superfluid helium temperatures by a cryogenic distribution system supplying cold supercritical helium. To reduce vapor fraction during the final Joule-Thomson (J-T) expansion into the superfluid helium cooling bath, counter-flow, plate-fin heat exchangers will be utilized. Due to their compact size and ease of fabrication, plate-fin heat exchangers are an effective option. However, the design of compact and high-effectiveness cryogenic heat exchangers operating at liquid helium temperatures requires consideration of axial heat conduction along the direction of flow, in addition to variable fluid properties. Here we present a numerical model that includes the effects of axial conduction and variable properties for a plate fin heat exchanger. The model is used to guide design decisions on heat exchanger material choice and geometry. In addition, the J-T expansion process is modeled with the heat exchanger to analyze the effect of heat load and cryogenic supply parameters. A numerical model that includes the effects of axial conduction and variable properties for a plate fin heat exchanger was developed and the effect of various design parameters on overall heat exchanger size was investigated. It was found that highly conductive metals should be avoided in the design of compact JT heat exchangers. For the geometry considered, the optimal conductivity is around 3.5 W/m-K and can range from 0.3-10 W/m-K without a large loss in performance. The model was implemented with an isenthalpic expansion process. Increasing the cold side inlet temperature from 2K to 2.2 K decreased the liquid fraction from 0.856 to 0.839 which corresponds to a 0.12 g/s increase in supercritical helium supply needed to maintain liquid level in the cooling bath. Lastly, it was found that the effectiveness increased when the heat load was below the design value. Therefore, the heat exchanger

  6. Study On the Performance of Solar Air Collectors with Cross V-Shaped Absorbing Plate and V-Shaped Bottom Plate%交叉V形吸热板V形底板空气集热器性能特性研究

    Institute of Scientific and Technical Information of China (English)

    闫崇强; 李明; 季旭; 罗熙

    2013-01-01

    以两种不同的交叉V形吸热板V形底板空气集热器(垂直型集热器:V形吸热板的方向与流道方向垂直,V形底板的方向与流道方向平行;平行型集热器:V形吸热板的方向与流道方向平行,V形底板的方向与流道方向垂直)为研究对象,对不同倾角、不同空气流速下两种空气集热器的性能进行了比较实验研究,同时对正向和反向通气时垂直型空气集热器的性能进行了测试分析.结果表明:垂直型空气集热器的性能优于平行型空气集热器,45°倾角时两台集热器的温升最高;垂直型和平行型空气集热器的最大效率分别为71%,68%;垂直型空气集热器反向流动时比正向流动时性能更好.%Two different types of solar air collectors with cross V-shaped absorbing plate and V-shaped bottom plate (for the vertical type collector,the direction of the V-shaped bottom plate is parallel to the flow direction while the direction of the V-shaped absorbing plate is perpendicular to it; for the parallel type collector,the direction of the V-shaped absorbing plate is parallel to the flow direction while the direction of the V-shaped bottom plate is perpendicular to it) are used as the research object in this paper,and their performances are studied and compared under different dip angle and different air flow velocity; meanwhile,the performance of the vertical type air collector is tested and analysed under forward and reverse entilation.The results show that the performance of the vertical type air collector is better than that of the parallel type air collector,and the rise of temperature of both collectors is the highest with an angle of 45°.The maximum efficiency of the vertical and the parallel type is 71% and 68%,respectively.With a reverse flow,the performance of the vertical type air collector is better than with a forward flow.

  7. The role of the heating mode of the mantle in intermittent reorganization of the plate velocity field

    Science.gov (United States)

    Lowman, Julian P.; King, Scott D.; Gable, Carl W.

    2003-02-01

    The geological record indicates that stages of relatively steady plate motion have been punctuated by comparatively brief periods in which plate velocities have reorganized. The distribution of buoyancy sources in the mantle has generally been regarded as evolving too slowly to explain these rapid transitions in plate velocity. We investigate the feedback between mantle convection and plate velocity using 2-D and 3-D mantle convection models that incorporate mobile dynamic plates. We focus on the influence of internal heating in the mantle and consider the effect of mantle viscosity stratification and different plate geometries on the plate velocity time dependence. As either the Rayleigh number or the internal heating rate is increased to magnitudes approaching mantle values, the record of the plate motion from our calculations becomes characterized by intermittent changes in direction. This behaviour is a result of the influence of plates on heat loss from the inherently unsteady, internally heated convecting system. Plate motion instills a pattern of organization on the underlying convection that reflects the plate geometry and results in the formation of sheet-like downwelling structures at convergent plate boundaries in both 2-D and 3-D calculations (in contrast, upwellings in 3-D models are not sheet-like). The role of the sheet-like downwellings is critical in the observed episodic reorganization of the plate velocities. Warm material below the plates is entrained by plate motion into regions enveloping the downwelling sheets. During periods of fairly steady plate motion, buoyancy associated with the build-up of heat around the downwelling sheets leads to the creation of an unstable convection pattern. This build-up of heat is dramatic in calculations with mantle-like internal heating rates and resists continued long-term plate motion towards mature downwellings. When there are limitations on the degree of freedom of the direction of plate movement, such as

  8. A Long Term Test of Differently Designed Evacuated Tubular Collectors

    DEFF Research Database (Denmark)

    Fan, Jianhua; Dragsted, Janne; Furbo, Simon

    2008-01-01

    carried out with different mean solar collector fluid temperatures and in different seasons of the year. The results of the measurements are presented in this paper. The influence of the mean solar collector fluid temperature on the thermal performance of the different collector designs will be discussed......During three years seven differently designed evacuated tubular collectors (ETCs) utilizing solar radiation from all directions have been investigated experimentally. The evacuated tubular solar collectors investigated include one SLL all-glass ETC from Tshinghua Solar Co. Ltd, four heat pipe ETCs...... of the inlet fluid to the collectors have been the same for all collectors. The volume flow rate through each of the collectors is adjusted so that the mean solar collector fluid temperature has been the same for all collectors. Thus a direct performance comparison is possible. The side-by-side tests were...

  9. Evaluation of Test Method for Solar Collector Efficiency

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    /S. The solar collector panel investigated has 16 parallel connected horizontal absorber fins. CFD (Computational Fluid Dynamics) simulations, calculations with a solar collector simulation program SOLEFF (Rasmussen and Svendsen, 1996) and thermal experiments are carried out in the investigation......The test method of the standard EN12975-2 (European Committee for Standardization, 2004) is used by European test laboratories to determine the efficiency of solar collectors. In the test methods the mean solar collector fluid temperature in the solar collector, Tm is determined by the approximated...... equation where Tin is the inlet temperature to the collector and Tout is the outlet temperature from the collector. The specific heat of the solar collector fluid is in the test method as an approximation determined as a constant equal to the specific heat of the solar collector fluid at the temperature Tm...

  10. MHD Stagnation Flow of a Newtonian Fluid towards a Uniformly Heated and Moving Vertical Plate

    Directory of Open Access Journals (Sweden)

    Mehmet Şirin Demir

    2016-01-01

    Full Text Available Stagnation flow of an electrically conducting incompressible viscous fluid towards a moving vertical plate in the presence of a constant magnetic field is investigated. By using the appropriate transformations for the velocity components and temperature, the partial differential equations governing flow and heat transfer are reduced to a set of nonlinear ordinary differential equations. These equations are solved approximately using a numerical technique for the following two problems: (i two-dimensional stagnation-point flow on a moving vertical plate, (ii axisymmetric stagnation-point flow on a moving vertical plate. The effects of non-dimensional parameters on the velocity components, wall shear stresses, temperature and heat transfer are examined carefully.

  11. Performance measurement of plate fin heat exchanger by exploration: ANN, ANFIS, GA, and SA

    Directory of Open Access Journals (Sweden)

    A.K. Gupta

    2017-01-01

    Full Text Available An experimental work is conducted on counter flow plate fin compact heat exchanger using offset strip fin under different mass flow rates. The training, testing, and validation set of data has been collected by conducting experiments. Next, artificial neural network merged with Genetic Algorithm (GA utilized to measure the performance of plate-fin compact heat exchanger. The main aim of present research is to measure the performance of plate-fin compact heat exchanger and to provide full explanations. An artificial neural network predicted simulated data, which verified with experimental data under 10–20% error. Then, the authors examined two well-known global search techniques, simulated annealing and the genetic algorithm. The proposed genetic algorithm and Simulated Annealing (SA results have been summarized. The parameters are impartially important for good results. With the emergence of a new data-driven modeling technique, Neuro-fuzzy based systems are established in academic and practical applications. The neuro-fuzzy interference system (ANFIS has also been examined to undertake the problem related to plate-fin heat exchanger performance measurement under various parameters. Moreover, Parallel with ANFIS model and Artificial Neural Network (ANN model has been created with emphasizing the accuracy of the different techniques. A wide range of statistical indicators used to assess the performance of the models. Based on the comparison, it was revealed that technical ANFIS improve the accuracy of estimates in the small pool and tropical ANN.

  12. Thermal deformation in a thin circular plate due to a partially distributed heat supply

    Indian Academy of Sciences (India)

    N L Khobragade; K C Deshmukh

    2005-08-01

    In this paper, we develop an integral transform to determine temperature distribution in a thin circular plate, subjected to a partially distributed and axisymmetric heat supply on the curved surface, and study the thermal deformation. The results, obtained in series form in terms of Bessel’s functions, are illustrated numerically.

  13. MHD Boundary Layer Slip Flow and Heat Transfer over a Flat Plate

    Institute of Scientific and Technical Information of China (English)

    Krishnendu Bhattacharyya; Swati Mukhopadhyay; G.C.Layek

    2011-01-01

    An analysis of magnetohydrodynamic (MHD) boundary layer flow and heat transfer over a flat plate with slip condition at the boundary is presented. A complete self-similar set of equations are obtained from the governing equations using similarity transformations and are solved by a shooting method. In the boundary slip condition no local similarity occurs. Velocity and temperature distributions within the boundary layer are presented. Our analysis reveals that the increase of magnetic and slip parameters reduce the boundary layer thickness and also enhance the heat transfer from the plate.%@@ An analysis of magnetohydrodynamic (MHD) boundary layer flow and heat transfer over a flat plate with slip condition at the boundary is presented.A complete self-similar set of equations are obtained from the governing equations using similarity transformations and are solved by a shooting method.In the boundary slip condition no local similarity occurs.Velocity and temperature distributions within the boundary layer are presented.Our analysis reveals that the increase of magnetic and slip parameters reduce the boundary layer thickness and also enhance the heat transfer from the plate.

  14. Experimental study on condensation heat transfer of steam on vertical titanium plates with different surface energies

    Energy Technology Data Exchange (ETDEWEB)

    Baojin, Qi; Li, Zhang; Hong, Xu; Yan, Sun [State-Key Laboratory of Chemical Engineering, School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai 200237 (China)

    2011-01-15

    Visual experiments were employed to investigate heat transfer characteristics of steam on vertical titanium plates with/without surface modifications for different surface energies. Stable dropwise condensation and filmwise condensation were achieved on two surface modification titanium plates, respectively. Dropwise and rivulet filmwise co-existing condensation form of steam was observed on unmodified titanium surfaces. With increase in the surface subcooling, the ratio of area ({eta}) covered by drops decreased and departure diameter of droplets increased, resulting in a decrease in condensation heat transfer coefficient. Condensation heat transfer coefficient decreased sharply with the values of {eta} decreasing when the fraction of the surface area covered by drops was greater than that covered by rivulets. Otherwise, the value of {eta} had little effect on the heat transfer performance. Based on the experimental phenomena observed, the heat flux through the surface was proposed to express as the sum of the heat flux through the dropwise region and rivulet filmwise region. The heat flux through the whole surface was the weighted mean value of the two regions mentioned above. The model presented explains the gradual change of heat transfer coefficient for transition condensation with the ratio of area covered by drops. The simulation results agreed well with the present experimental data when the subcooling temperature is lower than 10 C. (author)

  15. Analytical Thermal and Cost Optimization of Micro-Structured Plate-Fin Heat Sink

    DEFF Research Database (Denmark)

    Rezaniakolaei, Alireza; Rosendahl, Lasse

    Microchannel heat sinks have been widely used in the field of thermo-fluids due to the rapid growth in technological applications which require high rates of heat transfer in relatively small spaces and volumes. In this work, a micro plate-fin heat sink is optimized parametrically, to minimize...... the thermal resistance and to maximize the cost performance of the heat sink. The width and the height of the microchannels, and the fin thickness are analytically optimized at a wide range of pumping power. Using an effective numeric test, the generated equations also discuss the optimum parameters at three...... sizes of the substrate plat of the heat sink. Results show that, at any pumping power there are specific values of the channel width and fin thickness which produce minimum thermal resistance in the heat sink. The results also illustrate that, a larger channel width and a smaller fin thickness lead...

  16. Non-newtonian flow and pressure drop of pineapple juice in a plate heat exchanger

    Directory of Open Access Journals (Sweden)

    R. A. F. Cabral

    2010-12-01

    Full Text Available The study of non-Newtonian flow in plate heat exchangers (PHEs is of great importance for the food industry. The objective of this work was to study the pressure drop of pineapple juice in a PHE with 50º chevron plates. Density and flow properties of pineapple juice were determined and correlated with temperature (17.4 < T < 85.8ºC and soluble solids content (11.0 < Xs < 52.4 ºBrix. The Ostwald-de Waele (power law model described well the rheological behavior. The friction factor for non-isothermal flow of pineapple juice in the PHE was obtained for diagonal and parallel/side flow. Experimental results were well correlated with the generalized Reynolds number (20 < Re g < 1230 and were compared with predictions from equations from the literature. The mean absolute error for pressure drop prediction was 4% for the diagonal plate and 10% for the parallel plate.

  17. Simulation model for assessing the efficiency of a combined power installation based on a geothermal heat pump and a vacuum solar collector

    Science.gov (United States)

    Vaysman, Ya I.; Surkov, AA; Surkova, Yu I.; Kychkin, AV

    2017-06-01

    The article is devoted to the use of renewable energy sources and the assessment of the feasibility of their use in the climatic conditions of the Western Urals. A simulation model that calculates the efficiency of a combined power installations (CPI) was (RES) developed. The CPI consists of the geothermal heat pump (GHP) and the vacuum solar collector (VCS) and is based on the research model. This model allows solving a wide range of problems in the field of energy and resource efficiency, and can be applied to other objects using RES. Based on the research recommendations for optimizing the management and the application of CPI were given. The optimization system will give a positive effect in the energy and resource consumption of low-rise residential buildings projects.

  18. The thermal state of the Arabian plate derived from heat flow measurements in Oman and Yemen

    Science.gov (United States)

    Rolandone, Frederique; Lucazeau, Francis; Leroy, Sylvie; Mareschal, Jean-Claude; Jorand, Rachel; Goutorbe, Bruno; Bouquerel, Hélène

    2013-04-01

    The dynamics of the Afar plume and the rifting of the Red Sea and the Gulf of Aden affect the present-day thermal regime of the Arabian plate. However, the Arabian plate is a Precambrian shield covered on its eastern part by a Phanerozoic platform and its thermal regime, before the plume and rifting activities, should be similar to that of other Precambrian shields with a thick and stable lithosphere. The first heat flow measurements in the shield, in Saudi Arabia, yielded low values (35-44 mW/m2), similar to the typical shields values. Recent heat flow measurements in Jordan indicate higher values (56-66 mW/m2). As part of the YOCMAL project (YOung Conjugate MArgins Laboratory), we have conducted heat flow measurements in southern and northern Oman to obtain 10 new heat flux values in the eastern Arabian plate. We also derived 20 heat flux values in Yemen and Oman by processing thermal data from oil exploration wells. The surface heat flux in these different locations is uniformly low (45 mW/m2). The heat production in samples from the Dhofar and Socotra Precambrian basement is also low (0.7 µW/m3). Differences in heat flow between the eastern (60 mW/m2) and the western (45 mW/m2) parts of Arabia reflect differences in crustal heat production as well as a higher mantle heat flux in the west. We have calculated a steady state geotherm for the Arabian platform that intersects the isentropic temperature profile at a depth of about 150 km, consistent with the seismic observations. Seismic tomography studies of the mantle beneath Arabia also show this east-west contrast. Seismic studies have shown that the lithosphere is rather thin, 100 km or less below the shield and 150 km below the platform. The lithospheric thickness for the Arabian plate is 150 km, and the progressive thinning near the Red Sea, caused by the thermal erosion of the plume material, is too recent to be detected at the surface. The Afar plume mostly affects the base of the Arabian lithosphere along

  19. Studi Eksperimen Analisa Performa Compact Heat Exchanger Circular Tubes Continuous Plate Fin Untuk Pemanfaatan Waste Energy

    Directory of Open Access Journals (Sweden)

    Rachmadi Gewa Saputra

    2014-03-01

    Full Text Available Harga minyak dunia cenderung mengalami peningkatan dalam beberapa tahun terakhir sehingga manusia berfikir untuk memanfaatkan setiap penggunaan minyak bumi. Dengan berkembangnya teknologi saat ini waste energy yang berupa gas hasil pembakaran pada engine dapat dimanfaatkan menjadi bentuk energi lain menggunakan heat recovery system. Pada tugas akhir ini dilakukan desain sebuah heat exchanger tipe circular tubes continuous plate fin dengan susunan tube aligned yang digunakan untuk menyerap waste energy yang berupa exhaust gas. Untuk mendapatkan dimensi desain yang sesuai digunakan metode ΔTLMTD. Metode ini digunakan untuk menentukan nilai dari overall heat transfer  desain dari heat exchanger, kemudian dilakukan perhitungan untuk nilai overall heat transfer hitung. Setelah didapatkan nilai dari overall heat transfer secara desain dan hitung maka dilakukan iterasi untuk mendapatkan dimensi heat exchanger yang memiliki nilai error paling kecil antara nilai overall heat transfer desain dan hitung. Untuk pengujian performa dari heat exchanger yang telah didesain maka dilakukan variasi kacepatan exhaust gas yang melewati heat exchanger, yaitu 0.4 m/s, 0.3 m/s, dan 0.2 m/s. Exhaust gas yang digunakan memiliki temperatur 280oC. Pada tugas akhir ini didapatkan desain compact heat exchanger dengan dimensi panjang 0.38 m, lebar 0.45 m, dan tebal 0.04m. Setelah dilakukan pengujian dengan memvariasikan kecepatan dari exhaust gas yang melewati heat exchanger maka didapatkan bahwa nilai dari qaktual dari heat exchanger mengalami kenaikan dengan bertambahnya reynolds number akibat bertambahnya kecepatan exhaust gas, kemudian nilai dari effectiveness akan mengalami penurunan untuk setiap kenaikan dari reynold number exhaust gas. Selain itu nilai dari NTU heat exchanger juga mengalami penurunan dengan bertambahnya reynold number exhaust gas. Untuk nilai overall heat transfer dari heat exchanger yang didesain akan mengalami kenaikan akibat bertambahnya nilai

  20. Mean heat transfer coefficients during the evaporation of 1,1,1,2-tetrafluoroethane (R-134a) in a plate heat exchanger

    OpenAIRE

    EMILA DJORDJEVIC; STEPHAN KABELAC; SLOBODAN SERBANOVIC

    2007-01-01

    In this study the transfer coefficient of evaporation heat of the refrigerant 1,1,1,2-tetrafluoroethane (R-134a) in a vertical plate heat exchanger was experimentally investigated. The results are presented as the dependancy of the mean heat transfer coefficient for the whole heat exchanger on the mean vapor quality. The influences of mass flux, heat flux and flow configuration on the heat transfer coefficient were also taken into account and a comparison with previously published experimenta...

  1. Eddy current heating of irregularly shaped plates by slow ramped fields

    Energy Technology Data Exchange (ETDEWEB)

    Dresner, L.

    1979-09-01

    Eddy current heating of thin conducting plates of various shapes by a perpendicular field is studied, assuming that the magnetic field created by the eddy currents is negligible in comparison with the external field. The method is to introduce the stream function of the eddy currents, which is shown to satisfy Poisson's equation, and then employ a pair of complementary variational principles (i.e., a minimum principle and a maximum principle), the extrema of which equal the eddy current heating. Two such complementary principles give not only an estimate of the eddy current heating, but a bound on the error of the estimate as well.

  2. Study of Dynamic Buckling of FG Plate Due to Heat Flux Pulse

    Directory of Open Access Journals (Sweden)

    Czechowski L.

    2015-02-01

    Full Text Available The paper deals with a FEM analysis of dynamic buckling of functionally graded clamped plates under heat flux loading with huge power. The materials of structures as well as their properties are varying in each layer across the plate thickness formulated by the power law distribution. The heat flux was applied evenly to the whole ceramic surface. The analysis was developed in the ANSYS 14.5 software. The duration of the heat flux loading equal to a period of natural fundamental flexural vibrations of given structures was taken into consideration. To implement large deflections of structures, the Green-Lagrange nonlinear-displacement equations and the incremental Newton-Raphson algorithm were applied. An evaluation of the dynamic response of structures was carried out on basis of the Budiansky-Hutchinson criterion. The studies were conducted for different volume fraction distributions and different shapes of the heat flux loading. The computation results of the heat flux versus maximal plate deflection are shown and discussed.

  3. Natural COnvective Heat and Mass Transfer on a Vertical Heated Plate for Water Flow Containing Metal Corrosion Particles

    Institute of Scientific and Technical Information of China (English)

    Pei-xueJiang; Ze-peiRen; 等

    1992-01-01

    Corrosion products of structural materials when contained in water usually are in two states:soluble state and colloidal particles with dimeter about 10-3-10-1um,Deposits of such corrosion products on tube surfaces under high pressure will jeopardize the operating economy of power plant equipment and even esult in accidents.A numerical study is reported in this paper of the natural convective heat and mass transfer on a vertical heated plate subject to the flrst or mixed kind of boundary conditions for high-pressure water(P=17MPa) containing metal corrosion products with consideration of varialbe thermophysical properties.

  4. Unsteady Hydromagnetic Flow of Radiating Fluid Past a Convectively Heated Vertical Plate with the Navier Slip

    Directory of Open Access Journals (Sweden)

    O. D. Makinde

    2014-01-01

    Full Text Available This paper investigates the unsteady hydromagnetic-free convection of an incompressible electrical conducting Boussinesq’s radiating fluid past a moving vertical plate in an optically thin environment with the Navier slip, viscous dissipation, and Ohmic and Newtonian heating. The nonlinear partial differential equations governing the transient problem are obtained and tackled numerically using a semidiscretization finite difference method coupled with Runge-Kutta Fehlberg integration technique. Numerical data for the local skin friction coefficient and the Nusselt number have been tabulated for various values of parametric conditions. Graphical results for the fluid velocity, temperature, skin friction, and the Nusselt number are presented and discussed. The results indicate that the skin friction coefficient decreases while the heat transfer rate at the plate surface increases as the slip parameter and Newtonian heating increase.

  5. Three-dimensional structural analysis of the plate-fin heat exchanger

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, T.; Sou, T.

    1984-06-01

    The Brazed aluminum plate-fin heat exchanger is a complex structure consisting of a core, headers and nozzles. The core is built of many layers of flat parting sheets and corrugated fins, and is sealed by side bars. Stress patterns in this type of heat exchanger have so far not been accurately analyzed, due to the complexity of the structure. A three dimensional structural analysis of such a core-header-nozzle structure subject to internal pressure is performed herein, using the finite element method, in order to investigate the mechanical characteristics of the structure. In the analysis, the corrugated fin is modeled by an equivalent anisotropic continuum element, to save on the computational cost. The adequacy of the analysis is then verified by performing a strain measurement test on the actual plate-fin heat exchanger. On the basis of the analytical results, it becomes clear that some critical parts need special attention when designing such structures.

  6. HYSYS Automation and Its Application on Evaluation of Plate Heat Exchanger

    Institute of Scientific and Technical Information of China (English)

    Dai Yuqiang; Liu Wenwei; Wang Shaomin; Hu Dapeng

    2008-01-01

    When simulating or designing plate heat exchangers for multicomponent mixtures, most de-signers are often perplexed with the question on how to choose or estimate the physical property param-eters and hope to have a reliable database that could be adopted. The commercial codes HYSYS supply the physical property package on over 1500 pure substances and over 16 000 binary coefficients for them.This work has briefly presented an efficient communication interface based on the Microsoft Component Object Model (COM) between inner plate heat exchanger simulation codes and the HYSYS package. The application of a custom-made HYSYS-COM interface has shown high efficiency, such as significant re-duction of time needed for evaluating each process stream's properties. This automation method can be conveniently extended to further optimization study for any specific operation device such as heat transfers,columns, and other facilities.

  7. Mathematical model of a plate fin heat exchanger operating under solid oxide fuel cell working conditions

    Science.gov (United States)

    Kaniowski, Robert; Poniewski, Mieczysław

    2013-12-01

    Heat exchangers of different types find application in power systems based on solid oxide fuel cells (SOFC). Compact plate fin heat exchangers are typically found to perfectly fit systems with power output under 5 kWel. Micro-combined heat and power (micro-CHP) units with solid oxide fuel cells can exhibit high electrical and overall efficiencies, exceeding 85%, respectively. These values can be achieved only when high thermal integration of a system is assured. Selection and sizing of heat exchangers play a crucial role and should be done with caution. Moreover, performance of heat exchangers under variable operating conditions can strongly influence efficiency of the complete system. For that reason, it becomes important to develop high fidelity mathematical models allowing evaluation of heat exchangers under modified operating conditions, in high temperature regimes. Prediction of pressure and temperatures drops at the exit of cold and hot sides are important for system-level studies. Paper presents dedicated mathematical model used for evaluation of a plate fin heat exchanger, operating as a part of micro-CHP unit with solid oxide fuel cells.

  8. Synthetic fiber air collectors for agricultural uses

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, H.

    Details are given on an innovative air collector system made of porous black synthetic fibers to take in air and absorb solar radiation to heat it. Synthetic fiber collectors are unexpensive, they are characterized by their efficient heat transfers, good working properties, and wind resistance. Excessive heating, condensates, and dusts are avoided using them. Schematic sketches facilitate access to the fibrous structure, uses, design and construction of solar air collectors made of Nicolon fibers. Temperature and collector capacity measuring results are shown in a diagram. Details are given on a small-scale solar drier drying herbs (solar collector system with a 36 m/sup 2/ fibrous absorber surface) as well as on experiences gained in the operation of more than 20 solar driers of the kind described. (HWJ).

  9. Impact of the filling level on the global heat transfer coefficient of a plate cross section for sorption heat pumps

    Science.gov (United States)

    Giraud, Florine; Hamitouche, Yacine; Vallon, Pierrick; Tremeac, Brice

    2017-02-01

    Compact evaporator like plate heat exchangers can play a significant role in reducing the investment cost of low cooling power sorption systems. However, when water is used as refrigerant, the working pressure is very low and vaporization phenomena are really different than vaporization phenomena occurring at higher pressures. Few studies focus on this subject and there is a lack of knowledge about vaporization (boiling or evaporation) phenomena occurring in compact evaporators at low pressure. The design of such evaporators remain manly empirical. There is thus a need of better characterization of the influence of the driving parameters in order to optimize the evaporator design. The objective of this article is thus to go further in the understanding of phenomena occurring in compact plate-type evaporators. In that goal, an experimental campaign was conducted to study continuously the performance of a smooth plate type evaporator as a function of the filling levels. The influence of the saturation pressure and the secondary fluid temperature on an overall heat transfer coefficient is studied. It is show that there is a dependence of the maximal overall heat transfer coefficient to these parameters. It is also shown that there seems to be a strong dependence between phenomena observed and phenomena that happens before. Thus, dynamic and inertia effects must be taken into account and model developed in absorption configuration cannot be applied for this study.

  10. Developments in convective heat transfer models featuring seamless and selected detail surfaces, employing electroless plating

    Science.gov (United States)

    Stalmach, C. J., Jr.

    1975-01-01

    Several model/instrument concepts employing electroless metallic skin were considered for improvement of surface condition, accuracy, and cost of contoured-geometry convective heat transfer models. A plated semi-infinite slab approach was chosen for development and evaluation in a hypersonic wind tunnel. The plated slab model consists of an epoxy casting containing fine constantan wires accurately placed at specified surface locations. An electroless alloy was deposited on the plastic surface that provides a hard, uniformly thick, seamless skin. The chosen alloy forms a high-output thermocouple junction with each exposed constantan wire, providing means of determining heat transfer during tunnel testing of the model. A selective electroless plating procedure was used to deposit scaled heatshield tiles on the lower surface of a 0.0175-scale shuttle orbiter model. Twenty-five percent of the tiles were randomly selected and plated to a height of 0.001-inch. The purpose was to assess the heating effects of surface roughness simulating misalignment of tiles that may occur during manufacture of the spacecraft.

  11. Enhanced microwave absorbing properties and heat resistance of carbonyl iron by electroless plating Co

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hongyu, E-mail: wanghongyu07010310@163.com; Zhu, Dongmei; Zhou, Wancheng; Luo, Fa

    2015-11-01

    Co coated carbonyl iron particles (Co (CI)) are fabricated through electroless plating method, and the electromagnetic microwave absorbing properties are investigated in the frequencies during 8.2–12.4 GHz. The complex permittivity of CI particles after electroless plating Co is higher than that of raw CI particles due to improvment of the polarization process. Furthermore, according to the XRD and TG results, the Co layer can enhance the heat resistance of CI particles. The bandwidth below −10 dB can reach 3.9 GHz for the Co(CI) absorbent. The results indicate that the electroless plating Co not only enhances the absorbing properties but also improves the heat resistance of CI. - Highlights: • The Co-coated carbonyl iron Co(CI) particles were prepared by electroless plating. • The electromagnetic wave absorbing properties of Co(CI) particles were studied. • The heat treatment on the absorbing property of Co(CI) particles was studied. • The Co(CI) particles have good absorbing property when compared with CI.

  12. Preparation of zeolite a coatings on copper plates by using the substrate heating method

    Directory of Open Access Journals (Sweden)

    S. Teber

    2010-12-01

    Full Text Available The substrate heating method was used to grow zeolite 4A coatings on copper plates. The reaction mixture was kept at 25º C, while the plate was heated to a higher temperature. In some of the synthesis experiments performed, the reaction mixture was circulated in the system. The coatings prepared were characterized by X-ray diffraction and scanning electron microscopy. It was demonstrated that crystalline and pure zeolite 4A coatings could be formed on copper by using the substrate heating method from a highly alkaline solution, in which dissolution and oxidation of the copper plates took place. A coating with about 310 µm mass equivalent thickness could be grown on copper after 72 h of synthesis. The thickness decreased when circulation was applied. Compared to coatings previously prepared on stainless steel plates under similar experimental conditions, thicker coatings were grown on copper. It is possible that the roughened surface of copper in the highly alkaline reaction mixture provided a higher number of nucleation sites.

  13. Forced Convection Heat Transfer in Plate Channels Filled with Packed Beds or Sintered Porous Media

    Institute of Scientific and Technical Information of China (English)

    姜培学; 李勐; 任泽霈

    2002-01-01

    In the present work, forced convection heat transfer in plate channels filled with metallic or non-metallic particles (packed beds) or sintered porous media is simulated numerically using a thermal non-equilibrium model. The numerical simulation results are compared with experimental data. The difference between convection heat transfer in packed beds and in sintered porous media and the effects of the boundary condition assumptions are investigated. The results show that the numerical simulation of convection heat transfer of air or water in packed beds using the local thermal non-equilibrium model and the variable porosity model agrees well with the experimental data. The convection heat transfer coefficient in sintered porous media is much higher than that in packed beds. In the numerical simulation of convection heat transfer in sintered porous media, the boundary conditions on the wall should be that the particle temperatures are equal to the fluid temperature.

  14. Couette and Poiseuille flows in a low viscosity asthenosphere: Effects of internal heating rate, Rayleigh number, and plate representation

    Science.gov (United States)

    Shiels, C.; Butler, S. L.

    2015-09-01

    Mantle convection models with a low viscosity asthenosphere and high viscosity surface plates have been shown to produce very large aspect ratio convection cells like those inferred to exist in Earth's mantle and to exhibit two asthenospheric flow regimes. When the surface plate is highly mobile, the plate velocity exceeds the flow velocities in the asthenosphere and the plate drives a Couette-type flow in the asthenospheric channel. For sluggish plates, the flow velocities in the asthenosphere exceed the plate velocity and the asthenospheric flow is more Poiseuille-like. It has been shown that under certain circumstances, flows become increasingly Couette-like as the aspect ratio of the plate is increased in numerical simulations. These models also show an increase in the average surface heat flux with aspect ratio which is counterintuitive, as one would expect that large aspect ratio models would result in older and colder oceanic lithosphere. Previous investigations have used single internal heating rates and Rayleigh numbers and a plate formulation that did not preclude significant deformation within the plate. In this paper, we investigate the conditions necessary for Couette and Poiseuille asthenospheric flows and for surface heat flux to increase with plate aspect ratio by varying the internal heating rate, the Rayleigh number and the representation of surface plates in 2D mantle convection models Plates are represented as a high viscosity layer with (1) a free-slip top surface boundary condition and (2) a force-balance boundary condition that imposes a constant surface velocity within the plate. We find that for models with a free-slip surface boundary condition, the internal heating rate and Rayleigh number do not strongly affect the dominance of Couette or Poiseuille flows in the asthenosphere but the increase in surface heat flux with model aspect ratio in the Poiseuille asthenospheric flow regime increases with internal heating rate. For models using

  15. Experimental determination of correlations for mean heat transfer coefficients in plate fin and tube heat exchangers

    Science.gov (United States)

    Taler, Dawid

    2012-09-01

    This paper presents a numerical method for determining heat transfer coefficients in cross-flow heat exchangers with extended heat exchange surfaces. Coefficients in the correlations defining heat transfer on the liquid- and air-side were determined using a nonlinear regression method. Correlation coefficients were determined from the condition that the sum of squared liquid and air temperature differences at the heat exchanger outlet, obtained by measurements and those calculated, achieved minimum. Minimum of the sum of the squares was found using the Levenberg-Marquardt method. The uncertainty in estimated parameters was determined using the error propagation rule by Gauss. The outlet temperature of the liquid and air leaving the heat exchanger was calculated using the analytical model of the heat exchanger.

  16. Study of Cylindrical Honeycomb Solar Collector

    Directory of Open Access Journals (Sweden)

    Atish Mozumder

    2014-01-01

    Full Text Available We present the results of our investigation on cylindrical honeycomb solar collector. The honeycomb has been fabricated with transparent cellulose triacetate polymer sheets. Insulation characteristics of the honeycomb were studied by varying the separation between the honeycomb and the absorber plate. The optimal value of the separation was found to be 3.3 mm for which the heat transfer coefficient is 3.06 W m−2 K−1. This supports result of previous similar experiments. Further we test the honeycomb through a field experiment conducted in Delhi (28.6°N, 77°E and found that when the incident angle of the solar radiation is within 20° then the performance of the system with the honeycomb is better than the one without the honeycomb.

  17. Natural convective magneto-nanofluid flow and radiative heat transfer past a moving vertical plate

    Directory of Open Access Journals (Sweden)

    S. Das

    2015-03-01

    Full Text Available An investigation of the hydromagnetic boundary layer flow past a moving vertical plate in nanofluids in the presence of a uniform transverse magnetic field and thermal radiation has been carried out. Three different types of water-based nanofluids containing copper, aluminum oxide and titanium dioxide are taken into consideration. The governing equations are solved using Laplace transform technique and the solutions are presented in closed form. The numerical values of nanofluid temperature, velocity, the rate of heat transfer and the shear stress at the plate are presented graphically for several values of the pertinent parameters. The present study finds applications in engineering devices.

  18. Non-newtonian flow and pressure drop of pineapple juice in a plate heat exchanger

    OpenAIRE

    CABRAL, R. A. F.; GUT, J. A. W.; V. R. N. Telis; Telis-Romero, J. [UNESP

    2010-01-01

    The study of non-Newtonian flow in plate heat exchangers (PHEs) is of great importance for the food industry. The objective of this work was to study the pressure drop of pineapple juice in a PHE with 50º chevron plates. Density and flow properties of pineapple juice were determined and correlated with temperature (17.4 < T < 85.8ºC) and soluble solids content (11.0 < Xs < 52.4 ºBrix). The Ostwald-de Waele (power law) model described well the rheological behavior. The friction factor for non-...

  19. Combined photovoltaic and thermal hybrid collector systems

    Energy Technology Data Exchange (ETDEWEB)

    Kern, E.C. Jr.; Russell, M.C.

    1978-01-01

    Solar energy collectors that produce both electric and thermal energy are an attractive alternative to individual thermal and photovoltaic collectors for certain applications and climates. Economic results from a system analysis indicate that hybrid collector systems are attractive in small buildings that have substantial heating loads. Passively cooled photovoltaic panels are best suited for structures located in regions where year-round air conditioning and small, low-grade, thermal energy demands predominate. Hybrid collectors are to be tested according to ASHRAE standards and a full-system experiment incorporating a photovoltaic array installed at the Solar Energy Research Facility of the University of Texas will be conducted by Lincoln Laboratory.

  20. Optimized concentrating/passive tracking solar collector. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Sterne, K E; Johnson, A L; Grotheer, R H

    1979-01-01

    A concentrating solar collector having about half the material cost of other collectors with similar performance is described. The selected design is a Compound Parabolic Concentrator (CPC) which concentrates solar energy throughout the year without requiring realignment. Output is a fluid heated to 100/sup 0/C with good efficiency. The optical design of the reflector surface was optimized, yielding a 2.0:1 concentration ratio with a 60/sup 0/C acceptance angle and a low profile. Double glazing was chosen consisting of a polyester film outer glazing and an inner glazing of glass tubes around the absorbers. The selectively coated steel absorber tubes are connected in series with flexible plastic tubing. Much development effort went into the materials for the reflector subassembly. A laminate of metalized plastic film over plaster was chosen for the reflective surface. The reflector is rigidized by attaching filled epoxy header plates at each end. Aluminum side rails and an insulating back complete the structure. The finished design resulted in a material cost of $21.40 per square meter in production quantities. Performance testing of a prototype produced a 50% initial efficiency rating. This is somewhat lower than expected, and is due to materials and processes used in the prototype for the outer glazing, reflective surface and absorber coating. However, the efficiency curve drops only slightly with increasing temperature differential, showing the inherent advantage of the concentrator over flat plate collectors.

  1. The Development of Welded Plate Heat Exchanger with Tube Plates%焊接式板式换热器带管板片的研制

    Institute of Scientific and Technical Information of China (English)

    杨国庆; 王頠; 杨刚

    2016-01-01

    In order to analyse the heat transfer effect of welded plate heat exchangers more intuitively,and to improve the heat transfer efficiency,this article tends to developed a welded plate heat exchanger with a tube plate. After the application of the tube plate,it can help to measure the temperature distribution between the plates in the flow channel and the related data of the medium in the heat transfer process. Through the analysis of measured data,it is aim to optimize the combination form of the product flow process,and to give a guidance in heat transfer scheme with reasonable selections.%为更加直观的分析焊接式板式换热器的换热效果并提高其换热效率,研制了一种焊接式板式换热器带管板片。带管板片在焊接式板式换热器中应用后,可协助测量换热器在换热过程中板间流道的温度分布情况和介质的相关数据,通过对测量数据的分析,以期达到优化产品流程组合形式,为合理选择换热方案起指导作用。

  2. On applicability of plate and shell heat exchangers for steam generation in naval PWR

    Energy Technology Data Exchange (ETDEWEB)

    Freire, Luciano Ondir, E-mail: luciano.ondir@gmail.com; Andrade, Delvonei Alves de, E-mail: delvonei@ipen.br

    2014-12-15

    Highlights: • Given emissions restrictions, nuclear propulsion may be an alternative. • Plate and shell heat exchangers (PSHE) are a mature technology on market. • PSHE are compact and could be used as steam generators. • Preliminary calculations to obtain a PWR for a large container ship are performed. • Results suggest PSHE improve overall compactness and cost. - Abstract: The pressure on reduction of gas emissions is going to raise the price of fossil fuels and an alternative to fossil fuels is nuclear energy. Naval reactors have some differences from stationary PWR because they have limitations on volume and weight, requiring compact solutions. On the other hand, a source of problems in naval reactors across history is the steam generation function. In order to reduce nuclear containment footprint, it is desirable to employ integral designs, which, however, poses complications and design constraints for recirculation type steam generators, being interesting to employ once through steam generators, whose historic at Babcock and Wilcox is better than recirculation steam generators. Plate and shell heat exchangers are a mature technology made available by many suppliers which allows heat exchange at high temperature and pressure. This work investigates the feasibility of the use of an array of welded plate heat exchangers of a material approved by ASME for pressure barrier (Ti-3Al-2.5V) in a hypothetical naval reactor. It was found it is feasible from thermal-hydraulic point of view and presents advantages over other steam generator designs.

  3. Natural convection heat transfer of nanofluids along a vertical plate embedded in porous medium.

    Science.gov (United States)

    Uddin, Ziya; Harmand, Souad

    2013-02-07

    The unsteady natural convection heat transfer of nanofluid along a vertical plate embedded in porous medium is investigated. The Darcy-Forchheimer model is used to formulate the problem. Thermal conductivity and viscosity models based on a wide range of experimental data of nanofluids and incorporating the velocity-slip effect of the nanoparticle with respect to the base fluid, i.e., Brownian diffusion is used. The effective thermal conductivity of nanofluid in porous media is calculated using copper powder as porous media. The nonlinear governing equations are solved using an unconditionally stable implicit finite difference scheme. In this study, six different types of nanofluids have been compared with respect to the heat transfer enhancement, and the effects of particle concentration, particle size, temperature of the plate, and porosity of the medium on the heat transfer enhancement and skin friction coefficient have been studied in detail. It is found that heat transfer rate increases with the increase in particle concentration up to an optimal level, but on the further increase in particle concentration, the heat transfer rate decreases. For a particular value of particle concentration, small-sized particles enhance the heat transfer rates. On the other hand, skin friction coefficients always increase with the increase in particle concentration and decrease in nanoparticle size.

  4. Experimental Study on Frost Height of Round Plate Fin-Tube Heat Exchangers for Mobile Heat Pumps

    Directory of Open Access Journals (Sweden)

    Dong-Yeon Lee

    2012-09-01

    Full Text Available The objective of this study was to provide experimental data that could be used to predict frost growth and frost performance of a round plate fin-tube heat exchanger for low temperature heat pumps used in zero emission vehicles under cold weather conditions. In this study, round plate fin-tube heat exchangers were tested with variation of the fin space, air flow rate, relative humidity, and inlet air temperature. Frost height was measured and considered with the boundary layer interruption between fins. Frost height for 8.0 mm of fin space was increased by approximately 91.9% with an increase of relative humidity from 50.0% to 80.0%. The growth rate of frost height at 1.2 m3/min was observed to be 13.0% greater than that at 0.8 m3/min. Finally, the variation of the blockage ratio with fin space would be an important reference for designing advanced heat exchangers that operate under cold weather conditions.

  5. Estimation of spatially varying heat transfer coefficient from a flat plate with flush mounted heat sources using Bayesian inference

    Science.gov (United States)

    Jakkareddy, Pradeep S.; Balaji, C.

    2016-09-01

    This paper employs the Bayesian based Metropolis Hasting - Markov Chain Monte Carlo algorithm to solve inverse heat transfer problem of determining the spatially varying heat transfer coefficient from a flat plate with flush mounted discrete heat sources with measured temperatures at the bottom of the plate. The Nusselt number is assumed to be of the form Nu = aReb(x/l)c . To input reasonable values of ’a’ and ‘b’ into the inverse problem, first limited two dimensional conjugate convection simulations were done with Comsol. Based on the guidance from this different values of ‘a’ and ‘b’ are input to a computationally less complex problem of conjugate conduction in the flat plate (15mm thickness) and temperature distributions at the bottom of the plate which is a more convenient location for measuring the temperatures without disturbing the flow were obtained. Since the goal of this work is to demonstrate the eficiacy of the Bayesian approach to accurately retrieve ‘a’ and ‘b’, numerically generated temperatures with known values of ‘a’ and ‘b’ are treated as ‘surrogate’ experimental data. The inverse problem is then solved by repeatedly using the forward solutions together with the MH-MCMC aprroach. To speed up the estimation, the forward model is replaced by an artificial neural network. The mean, maximum-a-posteriori and standard deviation of the estimated parameters ‘a’ and ‘b’ are reported. The robustness of the proposed method is examined, by synthetically adding noise to the temperatures.

  6. 北京地区太阳能供暖系统集热器最佳倾角模拟分析%Simulation Analysis of the Best Angle for Solar Collector Heating System in Beijing Area

    Institute of Scientific and Technical Information of China (English)

    崔俊奎; 陈文婷

    2015-01-01

    According to the theory analysis of solar collector, using Polysun software, solar energy heat utilization dynamic simulation software, the paper analyzed and summarized the best angle and az-imuth angle for the collectors in Beijing area. A year-round best angle and azimuth angle is achieved for the flat solar collector.%对太阳能集热器进行理论分析,运用动态模拟软件Polysun对太阳能热利用进行仿真模拟,分析了北京地区集热器最佳倾角及其最佳方位角,计算得到全年使用时平板型太阳能集热器的最佳倾角及其最佳方位角。

  7. Determination Global Heat Transfer Coefficient in Shell and Tube Type and Plates Heat Exchangers

    OpenAIRE

    Duarte, José Arnaldo

    2012-01-01

    The literature on heat exchangers is very wide because of numerous existing configurations, several types of fluids used, as well as the variety of applications. On the other hand, when we need to calculate a heat exchanger, a similar procedure is hardly found. Therefore, we propose this educational work in order to facilitate the calculation procedures, when the student or the professional in the area needs a script for its design. The heat exchanger is installed in the Laboratory of Thermal...

  8. Time variability in Cenozoic reconstructions of mantle heat flow: plate tectonic cycles and implications for Earth's thermal evolution.

    Science.gov (United States)

    Loyd, S J; Becker, T W; Conrad, C P; Lithgow-Bertelloni, C; Corsetti, F A

    2007-09-04

    The thermal evolution of Earth is governed by the rate of secular cooling and the amount of radiogenic heating. If mantle heat sources are known, surface heat flow at different times may be used to deduce the efficiency of convective cooling and ultimately the temporal character of plate tectonics. We estimate global heat flow from 65 Ma to the present using seafloor age reconstructions and a modified half-space cooling model, and we find that heat flow has decreased by approximately 0.15% every million years during the Cenozoic. By examining geometric trends in plate reconstructions since 120 Ma, we show that the reduction in heat flow is due to a decrease in the area of ridge-proximal oceanic crust. Even accounting for uncertainties in plate reconstructions, the rate of heat flow decrease is an order of magnitude faster than estimates based on smooth, parameterized cooling models. This implies that heat flow experiences short-term fluctuations associated with plate tectonic cyclicity. Continental separation does not appear to directly control convective wavelengths, but rather indirectly affects how oceanic plate systems adjust to accommodate global heat transport. Given that today's heat flow may be unusually low, secular cooling rates estimated from present-day values will tend to underestimate the average cooling rate. Thus, a mechanism that causes less efficient tectonic heat transport at higher temperatures may be required to prevent an unreasonably hot mantle in the recent past.

  9. Study of corrosion in multimetallic systems. Task 2 of solar collector studies for solar heating and cooling applications. Final technical progress report

    Energy Technology Data Exchange (ETDEWEB)

    Diegle, R B

    1980-04-11

    Corrosion measurements were made on candidate alloys of construction for non-concentrating solar collectors under simulated conditions of collector operation. Materials evaluated were aluminum alloys 1100, 3003, and 6061, copper alloy 122, Type 444 stainless steel, and 1018 plain carbon steel. The solutions used were equivolume mixtures of ethylene glycol and water, and propylene glycol and water. They were used without corrosion inhibitors but with addition of chloride, sulfate, and bicarbonate ions. The influences of dissolved oxygen, solution flow velocity, and heat transfer were evaluated. Corrosion morphologies investigated were general attack, pitting, crevice corrosion, and galvanic corrosion. Experimental results indicated that aluminum alloys can experience severe pitting and crevice corrosion at chloride concentrations approaching 50 ppM. The corrosion rate of copper exceeded about 100 ..mu..m/yr in ethylene glycol solutions and about 80 ..mu..m/yr in propylene glycol solutions. Crevice corrosion was not observed for copper, but severe galvanic corrosion occurred when it was coupled to T444 stainless steel. T444 steel corroded at rates of less than 1 ..mu..m/yr under all exposure conditions. During circulation at 100 C in the presence of air, ethylene glycol solutions acidified because of degradation of the glycol. The initial pH of propylene glycol solutions was already low, about 4.5. The inherent corrosivity of propylene glycol was somewhat less than that of ethylene glycol, although this difference was usually less than a factor of two in measured corrosion rates. It was concluded that he corrosion rates of aluminum alloys and copper were prohibitively high in uninhibited glycol solutions, and that corrosion inhibitors are definitely necessary in operating systems.

  10. Unsteady boundary layer flow and heat transfer of a Casson fluid past an oscillating vertical plate with Newtonian heating.

    Science.gov (United States)

    Hussanan, Abid; Zuki Salleh, Mohd; Tahar, Razman Mat; Khan, Ilyas

    2014-01-01

    In this paper, the heat transfer effect on the unsteady boundary layer flow of a Casson fluid past an infinite oscillating vertical plate with Newtonian heating is investigated. The governing equations are transformed to a systems of linear partial differential equations using appropriate non-dimensional variables. The resulting equations are solved analytically by using the Laplace transform method and the expressions for velocity and temperature are obtained. They satisfy all imposed initial and boundary conditions and reduce to some well-known solutions for Newtonian fluids. Numerical results for velocity, temperature, skin friction and Nusselt number are shown in various graphs and discussed for embedded flow parameters. It is found that velocity decreases as Casson parameters increases and thermal boundary layer thickness increases with increasing Newtonian heating parameter.

  11. Local heat transfer coefficients during the evaporation of 1,1,1,2-tetrafluoroethane (R-134a in a plate heat exchanger

    Directory of Open Access Journals (Sweden)

    EMILA ŽIVKOVIĆ

    2009-04-01

    Full Text Available The evaporation heat transfer coefficient of the refrigerant R-134a in a vertical plate heat exchanger was investigated experimentally. The area of the plate was divided into several segments along the vertical axis. For each of the segments, the local value of the heat transfer coefficient was calculated and presented as a function of the mean vapor quality in the segment. Owing to the thermocouples installed along the plate surface, it was possible to determine the temperature distribution and vapor quality profile inside the plate. The influences of the mass flux, heat flux, pressure of system and the flow configuration on the heat transfer coefficient were also taken into account and a comparison with literature data was performed.

  12. Natural Convection Heat and Mass Transfer Flow with Hall Current, Rotation, Radiation and Heat Absorption Past an Accelerated Moving Vertical Plate with Ramped Temperature

    Directory of Open Access Journals (Sweden)

    Gauri Shanker Seth

    2015-01-01

    Full Text Available An investigation of unsteady hydromagnetic natural convection heat and mass trans fer flow with Hall current of a viscous, incompressible, electrically conducting, heat absorbing and optically thin radiating fluid past an accelerated moving vertical plate through fluid saturated porous medium in a rotating environment is carried out when temperature of the plate has a temporarily ramped profile. The exact solutions of momentum, energy and concentration equations are obtained in closed form by Laplace transform technique. The expressions of skin friction, Nusselt number and Sherwood number are also derived. For both ramped temperature and isothermal plates, Hall current tends to accelerate primary and secondary fluid velocities whereas heat absorption and radiation have reverse effect on it. Rotation tends to retard primary fluid velocity whereas it has a reverse effect on secondary fluid velocity. Heat absorption and radiation have tendency to enhance rate of heat transfer at the plate.

  13. UNSTEADY FREE CONVECTIVE FLOW PAST A MOVING VERTICAL POROUS PLATE WITH NEWTONIAN HEATING

    Directory of Open Access Journals (Sweden)

    SANKAR KUMAR GUCHHAIT

    2012-07-01

    Full Text Available The unsteady free convective flow past a vertical porous plate with Newtonian heating has been studied. The governing equations have been solved numerically by Crank-Nicolson implicit finite-difference scheme. The variations of velocity and fluid temperature are presented graphically. It is found that the fluid velocity decreases with an increase in Prandtl number. Both the fluid velocity and the fluid temperature increase with an increase in suction parameter. An increase in Grashof number leads to rise in the fluid velocity. Further, it is observed that the shear stress and the rate of heat transfer at the plate increase with an increase in either Prandtlnumber or suction parameter or time.

  14. Slip effects on MHD flow and heat transfer of ferrofluids over a moving flat plate

    Science.gov (United States)

    Ramli, Norshafira; Ahmad, Syakila; Pop, Ioan

    2017-08-01

    In this study, the problem of MHD flow and heat transfer of ferrofluids over a moving flat plate with slip effect and uniform heat flux is considered. The governing ordinary differential equations are solved via shooting method. The effect of slip parameter on the dimensionless velocity, temperature, skin friction and Nusselt numbers are numerically studied for the three selected ferroparticles; magnetite (Fe3O4), cobalt ferrite (CoFe2O4) and Mn-Zn ferrite (Mn-ZnFe2O4) with water-based fluid. The results indicate that dual solutions exist for a plate moving towards the origin. It is found that the slip process delays the boundary layer separation. Moreover, the velocity and thermal boundary-layer thicknesses decrease in the first solution while increase with the increase of the value of slip parameters in second solution.

  15. Testing the Corrosion Behaviour of Plated Aluminum Strips for Heat Exchangers Operating in the Automotive Industry

    Science.gov (United States)

    Nowak, Marek; Opyrchał, Mieczysław; Kłyszewski, Andrzej; Żelechowski, Janusz

    The automotive industry uses heat exchangers made of aluminum alloys. The radiators for an engine cooling system comprise elements (tubes) in which the coolant flows. These elements are made of AlMn alloys (e.g. AlMn or AlMnCu), while ribs are made from the sheet metal plated with AlSi alloys. While in service, the heat exchangers are exposed to harsh weather conditions, hence the need to ensure that the individual elements of the design are adequately protected from corrosion. One of the ways to obtain this protection is by modification of the chemical composition of aluminum alloys used in the manufacture of radiators. In this study, corrosion tests were carried out to characterise the investigated materials in terms of their corrosive behavior. The experiments included measurements of corrosion potential, testing of corrosion resistance in neutral salt spray, and electrochemical studies of selected plated AlMn alloy strips with different chemical composition.

  16. Magnetohydrodynamic mixed convective slip flow over an inclined porous plate with viscous dissipation and Joule heating

    Directory of Open Access Journals (Sweden)

    S. Das

    2015-06-01

    Full Text Available The combined effects of viscous dissipation and Joule heating on the momentum and thermal transport for the magnetohydrodynamic flow past an inclined plate in both aiding and opposing buoyancy situations have been carried out. The governing non-linear partial differential equations are transformed into a system of coupled non-linear ordinary differential equations using similarity transformations and then solved numerically using the Runge–Kutta fourth order method with shooting technique. Numerical results are obtained for the fluid velocity, temperature as well as the shear stress and the rate of heat transfer at the plate. The results show that there are significant effects of pertinent parameters on the flow fields.

  17. Rotating ferro-nanofluid over stretching plate under the effect of hall current and joule heating

    Science.gov (United States)

    Abdel-Wahed, Mohamed S.

    2017-05-01

    The behavior of boundary layer over a stretching plate filled with ferromagnetic Fe3O4 nanoparticles and subjected to magnetic field with hall current, joule heating and nonlinear thermal radiation has been investigated. The modeling based on nonlinear partial differential equations due to continuity, momentum and heat equations, these equations transformed to a system of nonlinear ordinary differential equations using similarity transformation technique then solved numerically. The effect of hall current, joule heating and thermal radiation on the physical quantities such as surface shear stress and heat flux have been investigated and discussed. Moreover, the velocities and temperature profiles of the boundary layer under the influence of the presented external forces plotted and discussed.

  18. Exact microscopic theory of electromagnetic heat transfer between a dielectric sphere and plate

    CERN Document Server

    Otey, Clayton

    2011-01-01

    Near-field electromagnetic heat transfer holds great potential for the advancement of nanotechnology. Whereas far-field electromagnetic heat transfer is constrained by Planck's blackbody limit, the increased density of states in the near-field enhances heat transfer rates by orders of magnitude relative to the conventional limit. Such enhancement opens new possibilities in numerous applications, including thermal-photo-voltaics, nano-patterning, and imaging. The advancement in this area, however, has been hampered by the lack of rigorous theoretical treatment, especially for geometries that are of direct experimental relevance. Here we introduce an efficient computational strategy, and present the first rigorous calculation of electromagnetic heat transfer in a sphere-plate geometry, the only geometry where transfer rate beyond blackbody limit has been quantitatively probed at room temperature. Our approach results in a definitive picture unifying various approximations previously used to treat this problem, ...

  19. Superconducting aluminum heat switch and plated press-contacts for use at ultralow temperatures.

    Science.gov (United States)

    Mueller, R M; Buchal, C; Oversluizen, T; Pobell, F

    1978-04-01

    We have measured the thermal conductivity of a 0.1-mm-thick Al foil in the normal and superconducting state down to 58 mK. At this temperature, our data give a ratio for the conductivities of k(n)/k(s)=1600 T(-2). They show that Al is a better material for a heat switch than the usually used superconductors because of its large k(n) and large Debye temperature (reducing the lattice conductivity k(s)). In addition, we describe the design of a heat switch and an excellent performing demountable press-contact between Al and Cu, both gold plated, as joint to the switch.

  20. Marangoni effect of cracked liquid film of an aqueous electrolyte flowing over a vertical heated plate

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    An experimental investigation was performed on Marangoni effect of cracked liquid film of aqueous Na2SO4 flowing over a vertical heated plate by using a sensitive infrared imaging technique. The results show that the thermal and solutal Marangoni effects, which result from the non-uniform distributions of surface temperature and concentration of the film, respectively, occur in the streamwise and transverse directions of the film, generating different influences on the film heat transfer. Taking account of the Marangoni number (Ma) and the solution concentration (c0), a correlation of the Nusselt number (Nu) for the cracked liquid film is proposed.