WorldWideScience

Sample records for plate augmentation group

  1. Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures.

    Science.gov (United States)

    Röderer, Götz; Scola, Alexander; Schmölz, Werner; Gebhard, Florian; Windolf, Markus; Hofmann-Fliri, Ladina

    2013-10-01

    Proximal humerus fracture fixation can be difficult because of osteoporosis making it difficult to achieve stable implant anchorage in the weak bone stock even when using locking plates. This may cause implant failure requiring revision surgery. Cement augmentation has, in principle, been shown to improve stability. The aim of this study was to investigate whether augmentation of particular screws of a locking plate aimed at a region of low bone quality is effective in improving stability in a proximal humerus fracture model. Twelve paired human humerus specimens were included. Quantitative computed tomography was performed to determine bone mineral density (BMD). Local bone quality in the direction of the six proximal screws of a standard locking plate (PHILOS, Synthes) was assessed using mechanical means (DensiProbe™). A three-part fracture model with a metaphyseal defect was simulated and fixed with the plate. Within each pair of humeri the two screws aimed at the region of the lowest bone quality according to the DensiProbe™ were augmented in a randomised manner. For augmentation, 0.5 ml of bone cement was injected in a screw with multiple outlets at its tip under fluoroscopic control. A cyclic varus-bending test with increasing upper load magnitude was performed until failure of the screw-bone fixation. The augmented group withstood significantly more load cycles. The correlation of BMD with load cycles until failure and BMD with paired difference in load cycles to failure showed that augmentation could compensate for a low BMD. The results demonstrate that augmentation of screws in locked plating in a proximal humerus fracture model is effective in improving primary stability in a cyclic varus-bending test. The augmentation of two particular screws aimed at a region of low bone quality within the humeral head was almost as effective as four screws with twice the amount of bone cement. Screw augmentation combined with a knowledge of the local bone quality

  2. Effectiveness of plate augmentation for femoral shaft nonunion after nailing

    Directory of Open Access Journals (Sweden)

    Chin-Jung Lin

    2012-08-01

    Conclusion: Plate augmentation with retention of the nail with autologous bone grafting may be an effective and reliable alternative in treating nonunion of the femoral shaft fracture after open reduction and internal fixation with intramedullary nail.

  3. Acromioclavicular joint reconstruction by coracoid process transfer augmented with hook plate.

    Science.gov (United States)

    Wang, Yeming; Zhang, Jianguo

    2014-06-01

    Various techniques have been reported for the treatment of chronic acromioclavicular (AC) joint separation. The purpose of this study was to evaluate the results of surgical construction of coracoclavicular ligament using coracoid process transfer augmented with a hook plate fixation. Twenty-one patients treated with coracoid process transfer augmented with a hook plate fixation for chronic type III and V AC injuries were retrospectively analysed in 2003-2009. The age of the patients ranged from 23 to 58 years with an average age of 41.6 years. The patients were followed up clinically and radiographically, with an average of 33.0 months. Functional status and the ability to return to work were recorded during follow-up. Constant score and visual analogue scale (VAS) for pain were measured. The mean Constant score has increased from 70.9 points preoperatively to 90.7 points at follow-up. The mean VAS score has decreased from 4.7 preoperatively to 1.2 at follow-up. The average abduction was 172°, forward flexion was 170° and external rotation was 56°. There were 10 excellent results, 10 good results and one fair result. All patients had resumed their job or returned to original sport activity at mean 3.7 months postoperatively. No reduction loss was observed after plate removal and the final follow-up. Despite retrospective nature of the study, the outcomes of surgical construction with process transfer augmented with hook plate fixation are promising for chronic type III and V AC injuries. Therapeutic level IV. Retrospective case series, treatment study. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. [Augmentation technique on the proximal humerus].

    Science.gov (United States)

    Scola, A; Gebhard, F; Röderer, G

    2015-09-01

    The treatment of osteoporotic fractures is still a challenge. The advantages of augmentation with respect to primary in vitro stability and the clinical use for the proximal humerus are presented in this article. In this study six paired human humeri were randomized into an augmented and a non-augmented group. Osteosynthesis was performed with a PHILOS plate (Synthes®). In the augmented group the two screws finding purchase in the weakest cancellous bone were augmented. The specimens were tested in a 3-part fracture model in a varus bending test. The augmented PHILOS plates withstood significantly more load cycles until failure. The correlation to bone mineral density (BMD) showed that augmentation could partially compensate for low BMD. The augmentation of the screws in locked plating in a proximal humerus fracture model is effective in improving the primary stability in a cyclic varus bending test. The targeted augmentation of two particular screws in a region of low bone quality within the humeral head was almost as effective as four screws with twice the amount of bone cement. Screw augmentation combined with a knowledge of the local bone quality could be more effective in enhancing the primary stability of a proximal humerus locking plate because the effect of augmentation can be exploited more effectively limiting it to the degree required. The technique of augmentation is simple and can be applied in open and minimally invasive procedures. When the correct procedure is used, complications (cement leakage into the joint) can be avoided.

  5. Age grouping to optimize augmentation success.

    Science.gov (United States)

    Gordon, Robert W

    2010-05-01

    This article has described the different age groups that present for noninvasive injectable lip and perioral augmentation, as well as the breakdown of 3 subgroups that present within the 4 general age groups. With the fundamental understanding of these presenting groups and subgroups, the practicing augmenter will be able to better treatment plan and educate the patient on realistic and optimal aesthetic outcomes.

  6. The treatment of nonisthmal femoral shaft nonunions with im nail exchange versus augmentation plating.

    Science.gov (United States)

    Park, Jin; Kim, Sul Gee; Yoon, Han Kook; Yang, Kyu Hyun

    2010-02-01

    The purpose of this study was to compare the results between exchange nailing (EN) and augmentation plating (AP) with a nail left in situ for nonisthmal femoral shaft nonunion after femoral nailing. : Retrospective data analysis, November 1996-March 2006. A level I trauma center. Eighteen patients with 18 nonisthmal femoral nonunions. Seven patients with 7 fractures treated for nonisthmal femoral shaft nonunions after femoral nailing with EN and 11 patients with 11 fractures treated for nonisthmal femoral shaft nonunions after nailing with AP combined with bone grafting. Union and complications. Five nonunions in the EN group failed to achieve union (72% failure rate), whereas all 11 pseudarthroses in the AP group obtained osseous union. Fisher exact test showed a higher nonunion rate of EN compared with AP for nonisthmal femoral shaft nonunion (odds ratio, 6.5; P = 0.002). AP with autogenous bone grafting may be a better option than EN for nonisthmal femoral nonunions.

  7. Anterior cement augmentation of adjacent levels after vertebral body replacement leads to superior stability of the corpectomy cage under cyclic loading-a biomechanical investigation.

    Science.gov (United States)

    Oberkircher, Ludwig; Krüger, Antonio; Hörth, Dominik; Hack, Juliana; Ruchholtz, Steffen; Fleege, Christoph; Rauschmann, Michael; Arabmotlagh, Mohammad

    2018-03-01

    In the operative treatment of osteoporotic vertebral body fractures, a dorsal stabilization in combination with a corpectomy of the fractured vertebral body might be necessary with respect to the fracture morphology, whereby the osteoporotic bone quality may possibly increase the risk of implant failure. To achieve better stability, it is recommended to use cement-augmented screws for dorsal instrumentation. Besides careful end plate preparation, cement augmentation of the adjacent end plates has also been reported to lead to less reduction loss. The aim of the study was to evaluate biomechanically under cyclic loading whether an additional cement augmentation of the adjacent end plates leads to improved stability of the inserted cage. Methodical cadaver study. Fourteen fresh frozen human thoracic spines with proven osteoporosis were used (T2-T7). After removal of the soft tissues, the spine was embedded in Technovit (Kulzer, Germany). Subsequently, a corpectomy of T5 was performed, leaving the dorsal ligamentary structures intact. After randomization with respect to bone quality, two groups were generated: Dorsal instrumentation (cemented pedicle screws, Medtronic, Minneapolis, MN, USA)+cage implantation (CAPRI Corpectomy Cage, K2M, Leesburg, VA, USA) without additional cementation of the adjacent endplates (Group A) and dorsal instrumentation+cage implantation with additional cement augmentation of the adjacent end plates (Group B). The subsequent axial and cyclic loading was performed at a frequency of 1 Hz, starting at 400 N and increasing the load within 200 N after every 500 cycles up to a maximum of 2,200 N. Load failure was determined when the cages sintered macroscopically into the end plates (implant failure) or when the maximum load was reached. One specimen in Group B could not be clamped appropriately into the test bench for axial loading because of a pronounced scoliotic misalignment and had to be excluded. The mean strength for implant

  8. Motivational Factors in Women Seeking Augmentation Mammoplasty Across Different Age Groups: A Cross-Sectional Survey.

    Science.gov (United States)

    Sherf, Matan; Wiser, Itay; Klein, Dov; Heller, Lior

    2018-02-19

    Augmentation mammoplasty is one of the most common esthetic procedures worldwide. A wide range of motivations leads women to undergo this procedure, among them socioeconomic status and age group. The aim of this study was to identify the motivation spectrum for augmentation mammoplasty through different age groups. We conducted a cross-sectional prospective survey given to Israeli women seeking augmentation mammoplasty consults in a hospital and private clinic settings, using a 17-item Motivation for Augmentation questionnaire. Three motivation domains were examined: appearance, sexuality and social. Study participants were divided into three age groups: 18-29, 30-39 and over 40 years. A total of 101 women participated in the study. Motivations were rated similar among all age groups. Appearance and sexuality domains were rated significantly higher compared with the social domain throughout all age groups (3.28 ± 0.91 and 3.15 ± 1.03 vs. 1.88 ± 1.16, p age. The desire to improve one's appearance and sexuality is more prominent than improving social and work status. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  9. The Effect of Polymethyl Methacrylate Augmentation on the Primary Stability of Cannulated Bone Screws in an Anterolateral Plate in Osteoporotic Vertebrae: A Human Cadaver Study.

    Science.gov (United States)

    Rüger, Matthias; Sellei, Richard M; Stoffel, Marcus; von Rüden, Christian

    2016-02-01

    Study Design Cohort study. Objective Expandable anterolateral plates facilitate the reduction of posttraumatic deformities of thoracolumbar spine injuries and are commonly used in cases of unstable injuries or compromised bone quality. In this in vitro study, the craniocaudal yield load of the osseous fixation of an anterior angular stable plate fixation system and the effect of polymethyl methacrylate (PMMA) screw augmentation on the primary stability of the screw-bone interface during kyphosis reduction was evaluated in 12 osteoporotic human thoracolumbar vertebrae. Methods The anterolateral stabilization device used for this study is comprised of two swiveling flanges and an expandable midsection. It facilitates the controlled reduction of kyphotic deformities in situ with a geared distractor. Single flanges were attached to 12 thoracolumbar vertebrae. Six specimens were augmented with PMMA by means of cannulated bone screws. The constructs were subjected to static, displacement-controlled craniocaudal loading to failure in a servohydraulic testing machine. Results The uncemented screws cut out at a mean 393 ± 66 N, whereas the cemented screws showed significantly higher yield load of 966 ± 166 N (p augmentation is an effective method to increase two- to threefold the primary stability of the screw-bone interface of an anterolateral spine stabilization system in osteoporotic bone. We recommend it in cases of severely compromised bone quality to reduce the risk of screw loosening during initial kyphosis correction and to increase long-term construct stability.

  10. Acromioclavicular joint dislocation: a comparative biomechanical study of the palmaris-longus tendon graft reconstruction with other augmentative methods in cadaveric models

    Directory of Open Access Journals (Sweden)

    Sengupta S

    2007-11-01

    Full Text Available Abstract Background Acromioclavicular injuries are common in sports medicine. Surgical intervention is generally advocated for chronic instability of Rockwood grade III and more severe injuries. Various methods of coracoclavicular ligament reconstruction and augmentation have been described. The objective of this study is to compare the biomechanical properties of a novel palmaris-longus tendon reconstruction with those of the native AC+CC ligaments, the modified Weaver-Dunn reconstruction, the ACJ capsuloligamentous complex repair, screw and clavicle hook plate augmentation. Hypothesis There is no difference, biomechanically, amongst the various reconstruction and augmentative methods. Study Design Controlled laboratory cadaveric study. Methods 54 cadaveric native (acromioclavicular and coracoclavicular ligaments were tested using the Instron machine. Superior loading was performed in the 6 groups: 1 in the intact states, 2 after modified Weaver-Dunn reconstruction (WD, 3 after modified Weaver-Dunn reconstruction with acromioclavicular joint capsuloligamentous repair (WD.ACJ, 4 after modified Weaver-Dunn reconstruction with clavicular hook plate augmentation (WD.CP or 5 after modified Weaver-Dunn reconstruction with coracoclavicular screw augmentation (WD.BS and 6 after modified Weaver-Dunn reconstruction with mersilene tape-palmaris-longus tendon graft reconstruction (WD. PLmt. Posterior-anterior (horizontal loading was similarly performed in all groups, except groups 4 and 5. The respective failure loads, stiffnesses, displacements at failure and modes of failure were recorded. Data analysis was carried out using a one-way ANOVA, with Student's unpaired t-test for unpaired data (S-PLUS statistical package 2005. Results Native ligaments were the strongest and stiffest when compared to other modes of reconstruction and augmentation except coracoclavicular screw, in both posterior-anterior and superior directions (p WD.ACJ provided additional

  11. Tracking Maneuvering Group Target with Extension Predicted and Best Model Augmentation Method Adapted

    Directory of Open Access Journals (Sweden)

    Linhai Gan

    2017-01-01

    Full Text Available The random matrix (RM method is widely applied for group target tracking. The assumption that the group extension keeps invariant in conventional RM method is not yet valid, as the orientation of the group varies rapidly while it is maneuvering; thus, a new approach with group extension predicted is derived here. To match the group maneuvering, a best model augmentation (BMA method is introduced. The existing BMA method uses a fixed basic model set, which may lead to a poor performance when it could not ensure basic coverage of true motion modes. Here, a maneuvering group target tracking algorithm is proposed, where the group extension prediction and the BMA adaption are exploited. The performance of the proposed algorithm will be illustrated by simulation.

  12. Surgical strategies to improve fixation in the osteoporotic spine: the effects of tapping, cement augmentation, and screw trajectory.

    Science.gov (United States)

    Kuhns, Craig A; Reiter, Michael; Pfeiffer, Ferris; Choma, Theodore J

    2014-02-01

    Study Design Biomechanical study of pedicle screw fixation in osteoporotic bone. Objective To investigate whether it is better to tap or not tap osteoporotic bone prior to placing a cement-augmented pedicle screw. Methods Initially, we evaluated load to failure of screws placed in cancellous bone blocks with or without prior tapping as well as after varying the depths of tapping prior to screw insertion. Then we evaluated load to failure of screws placed in bone block models with a straight-ahead screw trajectory as well as with screws having a 23-degree cephalad trajectory (toward the end plate). These techniques were tested with nonaugmented (NA) screws as well as with bioactive cement (BioC) augmentation prior to screw insertion. Results In the NA group, pretapping decreased fixation strength in a dose-dependent fashion. In the BioC group, the tapped screws had significantly greater loads to failure (p tapping prior to cement augmentation will substantially improve fixation when compared with not tapping. Angulating screws more cephalad also seems to enhance aging spine fixation.

  13. Determination of group velocity of propagation of Lamb waves in aluminium plate using piezoelectric transducers

    Directory of Open Access Journals (Sweden)

    Lašová Z.

    2017-06-01

    Full Text Available A prior knowledge of group velocities of Lamb wave modes is a key for analysis of time signals in guidedwave based structural health monitoring. The identification of multiple wave modes may be complicated due to dependency of group velocity on frequency (dispersion. These dependencies for infinite plate of constant thickness can be calculated by a numerical solution of analytic equation. Two alternative approaches to determine group velocities of zero-order Lamb wave modes in aluminum plate were used in this work: Two-dimensional Fast Fourier Transform (2D-FFT and methods of time-frequency processing. 2D-FFT requires a high number of time signals in equidistant points, therefore it was applied on data from finite element analysis of wave propagation in the plate. Group velocities for chosen frequencies were also determined using wavelet transform (WT of signals as differencies of times of arrival measured by a pair of piezoelectric transducers. The results from 2D-FFT and wavelet transform were compared to the analytic solution.

  14. Augmented reality

    Directory of Open Access Journals (Sweden)

    Patrik Pucer

    2011-08-01

    Full Text Available Today we can obtain in a simple and rapid way most of the information that we need. Devices, such as personal computers and mobile phones, enable access to information in different formats (written, pictorial, audio or video whenever and wherever. Daily we use and encounter information that can be seen as virtual objects or objects that are part of the virtual world of computers. Everyone, at least once, wanted to bring these virtual objects from the virtual world of computers into real environments and thus mix virtual and real worlds. In such a mixed reality, real and virtual objects coexist in the same environment. The reality, where users watch and use the real environment upgraded with virtual objects is called augmented reality. In this article we describe the main properties of augmented reality. In addition to the basic properties that define a reality as augmented reality, we present the various building elements (possible hardware and software that provide an insight into such a reality and practical applications of augmented reality. The applications are divided into three groups depending on the information and functions that augmented reality offers, such as help, guide and simulator.

  15. Group analysis for natural convection from a vertical plate

    Science.gov (United States)

    Rashed, A. S.; Kassem, M. M.

    2008-12-01

    The steady laminar natural convection of a fluid having chemical reaction of order n past a semi-infinite vertical plate is considered. The solution of the problem by means of one-parameter group method reduces the number of independent variables by one leading to a system of nonlinear ordinary differential equations. Two different similarity transformations are found. In each case the set of differential equations are solved numerically using Runge-Kutta and the shooting method. For each transformation different Schmidt numbers and chemical reaction orders are tested.

  16. One-stage lingual augmented urethroplasty in repair of distal penile ...

    African Journals Online (AJOL)

    E. Elsayed

    Abstract. Objectives: To evaluate the outcome of augmentation of shallow urethral plate by lingual graft in repair of distal penile hypospadias. Patients and methods: Between June 2008 and May 2011, the procedure was performed on 23 patients with mean age 2.3 years (range 1–3). All patients had distal penile ...

  17. INTEGRATIVE AUGMENTATION OF STANDARDIZED MANAGEMENT SYSTEMS

    Directory of Open Access Journals (Sweden)

    Stanislav Karapetrovic

    2008-03-01

    Full Text Available The development, features and integrating abilities of different international standards related to management systems are discussed. A group of such standards that augment the performance of quality management systems in organizations is specifically focused on. The concept, characteristics and an illustrative example of one augmenting standard, namely ISO 10001, are addressed. Integration of standardized augmenting systems, both by themselves and within the overall management system, is examined. It is argued that, in research and practice alike, integrative augmentation represents the future of standardized quality and other management systems.

  18. Diagnostic standards for dopaminergic augmentation of restless legs syndrome: report from a World Association of Sleep Medicine-International Restless Legs Syndrome Study Group consensus conference at the Max Planck Institute.

    Science.gov (United States)

    García-Borreguero, Diego; Allen, Richard P; Kohnen, Ralf; Högl, Birgit; Trenkwalder, Claudia; Oertel, Wolfgang; Hening, Wayne A; Paulus, Walter; Rye, David; Walters, Arthur; Winkelmann, Juliane; Earley, Christopher J

    2007-08-01

    Augmentation of symptom severity is the main complication of dopaminergic treatment of restless legs syndrome (RLS). The current article reports on the considerations of augmentation that were made during a European Restless Legs Syndrome Study Group (EURLSSG)-sponsored Consensus Conference in April 2006 at the Max Planck Institute (MPI) in Munich, Germany, the conclusions of which were endorsed by the International RLS Study Group (IRLSSG) and the World Association of Sleep Medicine (WASM). The Consensus Conference sought to develop a better understanding of augmentation and generate a better operational definition for its clinical identification. Current concepts of the pathophysiology, clinical features, and therapy of RLS augmentation were evaluated by subgroups who presented a summary of their findings for general consideration and discussion. Recent data indicating sensitivity and specificity of augmentation features for identification of augmentation were also evaluated. The diagnostic criteria of augmentation developed at the National Institutes of Health (NIH) conference in 2002 were reviewed in light of current data and theoretical understanding of augmentation. The diagnostic value and criteria for each of the accepted features of augmentation were considered by the group. A consensus was then developed for a revised statement of the diagnostic criteria for augmentation. Five major diagnostic features of augmentation were identified: usual time of RLS symptom onset each day, number of body parts with RLS symptoms, latency to symptoms at rest, severity of the symptoms when they occur, and effects of dopaminergic medication on symptoms. The quantitative data available relating the time of RLS onset and the presence of other features indicated optimal augmentation criteria of either a 4-h advance in usual starting time for RLS symptoms or a combination of the occurrence of other features. A paradoxical response to changes in medication dose also indicates

  19. Comparison of skeletal stability after sagittal split ramus osteotomy among mono-cortical plate fixation, bi-cortical plate fixation, and hybrid fixation using absorbable plates and screws.

    Science.gov (United States)

    Ueki, Koichiro; Moroi, Akinori; Yoshizawa, Kunio; Hotta, Asami; Tsutsui, Takamitsu; Fukaya, Kenichi; Hiraide, Ryota; Takayama, Akihiro; Tsunoda, Tatsuta; Saito, Yuki

    2017-02-01

    The purpose of this study was to examine skeletal stability and plate breakage after sagittal split ramus osteotomy (SSRO) with the mono-cortical plate fixation, bi-cortical plate fixation, and hybrid fixation techniques using absorbable plates and screws. A total of 76 Japanese patients diagnosed with mandibular prognathism with and without maxillary deformity were divided into 3 groups randomly. A total of 28 patients underwent SSRO with mono-cortical plate fixation, 23 underwent SSRO with bi-cortical plate fixation, and 25 underwent SSRO with hybrid fixation. Skeletal stability and horizontal condylar angle were analyzed by axial, frontal, and lateral cephalograms from before the operation to 1 year postoperatively. Breakage of the plate and screws was observed by 3-dimensional computed tomography (3DCT) immediately after surgery and after 1 year. Although there was a significant difference between the mono-cortical plate fixation group and hybrid fixation group regarding right MeAg in T1 (P = 0.0488) and occlusal plane in T1 (P = 0.0346), there were no significant differences between the groups for the other measurements in each time interval. In 2 cases, namely, 6 sides in the mono-cortical plate fixation group, breakage of the absorbable plate was found by 3DCT. However, there was no breakage in the bi-cortical plate fixation group and hybrid fixation group. This study results suggested that there were no significant differences in the postoperative skeletal stability among the 3 groups, and bi-cortical fixation as well as hybrid fixation was a reliable and useful method to prevent plate breakage even if an absorbable material was used. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  20. Mobile Collaborative Augmented Reality: The Augmented Stroll

    OpenAIRE

    Renevier , Philippe; Nigay , Laurence

    2001-01-01

    International audience; The paper focuses on Augmented Reality systems in which interaction with the real world is augmented by the computer, the task being performed in the real world. We first define what mobile AR systems, collaborative AR systems and finally mobile and collaborative AR systems are. We then present the augmented stroll and its software design as one example of a mobile and collaborative AR system. The augmented stroll is applied to Archaeology in the MAGIC (Mobile Augmente...

  1. Group-invariant solutions of nonlinear elastodynamic problems of plates and shells

    International Nuclear Information System (INIS)

    Dzhupanov, V.A.; Vassilev, V.M.; Dzhondzhorov, P.A.

    1993-01-01

    Plates and shells are basic structural components in nuclear reactors and their equipment. The prediction of the dynamic response of these components to fast transient loadings (e.g., loadings caused by earthquakes, missile impacts, etc.) is a quite important problem in the general context of the design, reliability and safety of nuclear power stations. Due to the extreme loading conditions a more adequate treatment of the foregoing problem should rest on a suitable nonlinear shell model, which would allow large deflections of the structures regarded to be taken into account. Such a model is provided in the nonlinear Donnell-Mushtari-Vlasov (DMV) theory. The governing system of equations of the DMV theory consists of two coupled nonlinear fourth order partial differential equations in three independent and two dependent variables. It is clear, as the case stands, that the obtaining solutions to this system directly, by using any of the general analytical or numerical techniques, would involve considerable difficulties. In the present paper, the invariance of the governing equations of DMV theory for plates and cylindrical shells relative to local Lie groups of local point transformations will be employed to get some advantages in connection with the aforementioned problem. First, the symmetry of a functional, corresponding to the governing equations of DMV theory for plates and cylindrical shells is studied. Next, the densities in the corresponding conservation laws are determined on the basis of Noether theorem. Finally, we study a class of invariant solutions of the governing equations. As is well known, group-invariant solutions are often intermediate asymptotics for a wider class of solutions of the corresponding equations. When such solutions are considered, the number of the independent variables can be reduced. For the class of invariant solutions studied here, the system of governing equations converts into a system of ordinary differential equations

  2. Studying with the cloud: the use of online Web-based resources to augment a traditional study group format.

    Science.gov (United States)

    Chan, Teresa; Sennik, Serena; Zaki, Amna; Trotter, Brendon

    2015-03-01

    Cloud-based applications such as Google Docs, Skype, Dropbox, and SugarSync are revolutionizing the way that we interact with the world. Members of the millennial generation (those born after 1980) are now becoming senior residents and junior attending physicians. We describe a novel technique combining Internet- and cloud-based methods to digitally augment the classic study group used by final-year residents studying for the Royal College of Physicians and Surgeons of Canada examination. This material was developed by residents and improved over the course of 18 months. This is an innovation report about a process for enhanced communication and collaboration as there has been little research to date regarding the augmentation of learner-driven initiatives with virtual resources.

  3. MyPlate Food Guide

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español MyPlate Food Guide KidsHealth / For Teens / MyPlate Food Guide What's ... and other sugary drinks. Avoid large portions . Five Food Groups Different food groups have different nutrients and ...

  4. Outcomes of rotator cuff augmentation surgery with autologous fascia lata.

    Science.gov (United States)

    Rosales-Varo, A P; García-Espona, M A; Roda-Murillo, O

    To evaluate whether augmentation grafts using autologous fascia lata improve functional results for rotator cuff repairs and reduce the retear rate compared to those without augmentation. This is a prospective evaluation comprising 20 patients with a complete symptomatic rotator cuff tear. The operations were carried out from a superior approach performing a total cuff repair, for 10 patients we used a suture augmented with an autologous graft taken from their own fascia lata while unaugmented sutures were used for the other 10 patients. The follow-up period lasted for one year post-intervention. We measured variables for tear type, functionality and pain, both baseline and at 6 and 12-month follow ups. We evaluated retear incidence in each group as well as each group's pain and functionality response. The improved pain levels in the non-graft group evolved gradually over time. Conversely, in the group with the augmentation grafts, average Constant-Murley shoulder outcome scores at six months were already above 10 and were maintained at 12 months. One retear occurred in the graft group and 2 in the group without grafts, thus presenting no significant differences. There were no significant changes in pain and function values at the one year follow up in either group. Our preliminary results regarding rotator cuff augmentation surgery with autologous fascia lata showed a significant improvement in pain levels after 6 months compared to the patients with no augmentation, who required 12 months to reach the same values. After a year of follow up, there were no differences between the mean Constant and pain scores in either intervention group The number of retears in the non-graft group was greater than that in the group with grafts although the difference was not significant. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  5. Electroless metal plating of plastics

    International Nuclear Information System (INIS)

    Krause, L.J.

    1986-01-01

    The product of an electroless plating process is described for plating at least one main group metal directly on a surface of a polymeric substrate comprising the steps of forming a nonaqueous solution containing a metallic salt of an alkali metal in a positive valence state and at least one main group metal in a negative valence state, the main group metal being selected from the group consisting of Ge, Sn, Pb, As, Sb, Bi, Si and Te, selecting an aromatic polymeric substrate reducible by the solublized salt and resistant to degration during the reaction, and carrying out a redox reaction between the salt in solution and the substrate by contacting the solution with the substrate for a sufficient time to oxidize and deposit the main group metal in elemental form to produce a plated substrate. The product is characterized by the plated metal being directly on the surface of the polymeric substrate and the alkali metal being retained in the plated substrate with the substrate being negatively charged with electrons transferred from the main group metal during the redox reaction

  6. Investigation of vertebral ''end plate sclerosis''

    International Nuclear Information System (INIS)

    Lee, S.W.; Mathie, A.G.; Jackson, J.E.; Hughes, S.P.F.

    2001-01-01

    To evaluate the association between vertebral ''end plate sclerosis'' and neck pain. A retrospective study was carried out of lateral cervical spine radiographs with a Picture Archive and Communication System (PACS). Two hundred patients' files were randomly assessed, comprising four equal groups, A to D. The mean ages of the patients were 62±7.4 years, 61±7.5 years, 40±5.6 years and 23±5.6 years respectively. In group A, all patients had symptoms of neck pain and a radiographic diagnosis of ''end plate sclerosis'' of the cervical spine. In groups B to D, asymptomatic patients were recruited and their age groups were 50-69, 30-49 and 10-29 years respectively. Using the PACS, the radiographic density and the sagittal diameter, thickness and area of the end plates at the C5 level were measured. Results and conclusions: No significant differences were found in the radiographic density of the end plates either between the symptomatic and asymptomatic groups (groups A and B), or between different age groups (groups B, C and D). A significant increase in end plate area and thickness was found, however, in both group B (P<0.005) and group C (P<0.01) in comparison with group D. This indicates that the extent of end plate sclerosis increases with age. Our results suggest that the radiographic density of cervical vertebral end plates correlates neither with neck pain nor with increasing age. The radiological sign of ''end plate sclerosis'' may be over-reported, further limiting its value in the assessment of patients with cervical spondylosis. (orig.)

  7. Orthobiologics in the augmentation of osteoporotic fractures.

    Science.gov (United States)

    Watson, J Tracy; Nicolaou, Daemeon A

    2015-02-01

    Many orthobiologic adjuvants are available and widely utilized for general skeletal restoration. Their use for the specific task of osteoporotic fracture augmentation is less well recognized. Common conductive materials are reviewed for their value in this patient population including the large group of allograft adjuvants categorically known as the demineralized bone matrices (DBMs). Another large group of alloplastic materials is also examined-the calcium phosphate and sulfate ceramics. Both of these materials, when used for the proper indications, demonstrate efficacy for these patients. The inductive properties of bone morphogenic proteins (BMPs) and platelet concentrates show no clear advantages for this group of patients. Systemic agents including bisphosphonates, receptor activator of nuclear factor κβ ligand (RANKL) inhibitors, and parathyroid hormone augmentation all demonstrate positive effects with this fracture cohort. Newer modalities, such as trace ion bioceramic augmentation, are also reviewed for their positive effects on osteoporotic fracture healing.

  8. Sigmoid plate dehiscence: Congenital or acquired condition?

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Zhaohui, E-mail: lzhtrhos@163.com [Capital Medical University, Beijing Tongren Hospital, No 1 Dong Jiao Min Street, Dongcheng District, Beijing 100730 (China); Li, Jing, E-mail: lijingxbh@yahoo.com.cn [Capital Medical University, Beijing Tongren Hospital, No 1 Dong Jiao Min Street, Dongcheng District, Beijing 100730 (China); Zhao, Pengfei, E-mail: zhaopengf05@163.com [Capital Medical University, Beijing Friendship Hospital, No 95 Yongan Road, Xicheng District, Beijing 100050 (China); Lv, Han, E-mail: chrislvhan@126.com [Capital Medical University, Beijing Friendship Hospital, No 95 Yongan Road, Xicheng District, Beijing 100050 (China); Dong, Cheng, E-mail: derc007@sina.com [Capital Medical University, Beijing Friendship Hospital, No 95 Yongan Road, Xicheng District, Beijing 100050 (China); Liu, Wenjuan, E-mail: wenjuanliu@163.com [Jining No. 1 People' s Hospital, No. 6 Health Street, Jining 272100 (China); Wang, Zhenchang, E-mail: cjr.wzhch@vip.163.com [Capital Medical University, Beijing Friendship Hospital, No 95 Yongan Road, Xicheng District, Beijing 100050 (China)

    2015-05-15

    Highlights: • CT with multiplanar reformations can accurately display the sigmoid platet dehiscence. • The prevalence of sigmoid plate dehiscence was no significant difference among different age groups. • The size of sigmoid plate bony defects were not statistically different among different age groups. • The sigmoid plate dehiscence is more commonly a congenital than an acquired condition. - Abstract: Background and purpose: The imaging features of sigmoid plate dehiscence-induced pulsatile tinnitus have been presented. The origin of the sigmoid plate dehiscence, however, remains unclear. Our aim was to assess the prevalence and extent of sigmoid plate dehiscence on computed tomography (CT) images in multiple age groups to determine whether this condition is more likely to be congenital or acquired. Materials and methods: We retrospectively reviewed contrast-enhanced CT images of sigmoid plates of temporal bones in 504 patients. Each temporal bone was characterized as normal or dehiscent. Patients were then subcategorized into four age groups, and the prevalence and extent of dehiscent sigmoid plates in each group were calculated and compared. Results: Overall, 80 patients had sigmoid plate dehiscence, nine of whom had it bilaterally. In successively older age groups, the prevalences of sigmoid plate dehiscence were 18.9%, 20.1%, 14.5%, and 12.7%, respectively. Respective average anteroposterior bony defect diameters were 3.7 ± 1.7, 3.0 ± 1.3, 3.1 ± 1.5, and 3.0 ± 1.1 mm. Respective average vertical bony defect diameters were 3.6 ± 2.3, 2.6 ± 1.2, 3.2 ± 1.5, and 3.0 ± 1.7 mm. The prevalence and extent of sigmoid plate dehiscence were not statistically different among the four age groups. Conclusions: The similar radiologic prevalence and extent of dehiscent sigmoid plates among the age groups suggest that the dehiscence is more commonly a congenital than an acquired condition.

  9. Sigmoid plate dehiscence: Congenital or acquired condition?

    International Nuclear Information System (INIS)

    Liu, Zhaohui; Li, Jing; Zhao, Pengfei; Lv, Han; Dong, Cheng; Liu, Wenjuan; Wang, Zhenchang

    2015-01-01

    Highlights: • CT with multiplanar reformations can accurately display the sigmoid platet dehiscence. • The prevalence of sigmoid plate dehiscence was no significant difference among different age groups. • The size of sigmoid plate bony defects were not statistically different among different age groups. • The sigmoid plate dehiscence is more commonly a congenital than an acquired condition. - Abstract: Background and purpose: The imaging features of sigmoid plate dehiscence-induced pulsatile tinnitus have been presented. The origin of the sigmoid plate dehiscence, however, remains unclear. Our aim was to assess the prevalence and extent of sigmoid plate dehiscence on computed tomography (CT) images in multiple age groups to determine whether this condition is more likely to be congenital or acquired. Materials and methods: We retrospectively reviewed contrast-enhanced CT images of sigmoid plates of temporal bones in 504 patients. Each temporal bone was characterized as normal or dehiscent. Patients were then subcategorized into four age groups, and the prevalence and extent of dehiscent sigmoid plates in each group were calculated and compared. Results: Overall, 80 patients had sigmoid plate dehiscence, nine of whom had it bilaterally. In successively older age groups, the prevalences of sigmoid plate dehiscence were 18.9%, 20.1%, 14.5%, and 12.7%, respectively. Respective average anteroposterior bony defect diameters were 3.7 ± 1.7, 3.0 ± 1.3, 3.1 ± 1.5, and 3.0 ± 1.1 mm. Respective average vertical bony defect diameters were 3.6 ± 2.3, 2.6 ± 1.2, 3.2 ± 1.5, and 3.0 ± 1.7 mm. The prevalence and extent of sigmoid plate dehiscence were not statistically different among the four age groups. Conclusions: The similar radiologic prevalence and extent of dehiscent sigmoid plates among the age groups suggest that the dehiscence is more commonly a congenital than an acquired condition

  10. Biomechanical comparison of double-row locking plates versus single- and double-row non-locking plates in a comminuted metacarpal fracture model.

    Science.gov (United States)

    Gajendran, Varun K; Szabo, Robert M; Myo, George K; Curtiss, Shane B

    2009-12-01

    Open or unstable metacarpal fractures frequently require open reduction and internal fixation. Locking plate technology has improved fixation of unstable fractures in certain settings. In this study, we hypothesized that there would be a difference in strength of fixation using double-row locking plates compared with single- and double-row non-locking plates in comminuted metacarpal fractures. We tested our hypothesis in a gap metacarpal fracture model simulating comminution using fourth-generation, biomechanical testing-grade composite sawbones. The metacarpals were divided into 6 groups of 15 bones each. Groups 1 and 4 were plated with a standard 6-hole, 2.3-mm plate in AO fashion. Groups 2 and 5 were plated with a 6-hole double-row 3-dimensional non-locking plate with bicortical screws aimed for convergence. Groups 3 and 6 were plated with a 6-hole double-row 3-dimensional locking plate with unicortical screws. The plated metacarpals were then tested to failure against cantilever apex dorsal bending (groups 1-3) and torsion (groups 4-6). The loads to failure in groups 1 to 3 were 198 +/- 18, 223 +/- 29, and 203 +/- 19 N, respectively. The torques to failure in groups 4 to 6 were 2,033 +/- 155, 3,190 +/- 235, and 3,161 +/- 268 N mm, respectively. Group 2 had the highest load to failure, whereas groups 5 and 6 shared the highest torques to failure (p row plates had equivalent bending and torsional stiffness, significantly higher than observed for the single-row non-locking plate. No other statistical differences were noted between groups. When subjected to the physiologically relevant forces of apex dorsal bending and torsion in a comminuted metacarpal fracture model, double-row 3-dimensional non-locking plates provided superior stability in bending and equivalent stability in torsion compared with double-row 3-dimensional locking plates, whereas single-row non-locking plates provided the least stability.

  11. An investigation of heat transfer augmentation and friction characteristics in solar air heater duct with V-shaped wire as artificial roughness on absorber plate

    Energy Technology Data Exchange (ETDEWEB)

    Madhukeshwara, N. [Department of Mechanical Engineering, B.I.E.T, Davanagere, Karnataka (India); Prakash, E.S. [Department of Studies in Mechanical Engineering, U.B.D.T.C.E, Davanagere, Karnataka (India)

    2013-07-01

    An experimental investigation of heat transfer augmentation and friction characteristics of fully developed turbulent flow in a rectangular duct of solar air heater with absorber plate having V-shaped wire ribs as artificial roughness on its underside is carried out. The investigation covers wide range of different parameters of wire ribbed roughness: relative roughness pitch (p/e) from 10 to 40, relative roughness height (e/Dh) from 0.01 to 0.04 and angle of attack of flow from 20° to 90°. Duct aspect ratio (W/B) is kept 5 and Reynolds number (Re) is varied from 2,500 to 8,500. The heat transfer and friction factor values obtained are compared with those of smooth duct under similar flow conditions. Expressions are developed for Nusselt number and friction factor for the roughness geometry. Enhancement of Nusselt number and friction factor for roughened duct are 1.5 and 2.7 times of smooth duct respectively.

  12. Towards Pervasive Augmented Reality: Context-Awareness in Augmented Reality.

    Science.gov (United States)

    Grubert, Jens; Langlotz, Tobias; Zollmann, Stefanie; Regenbrecht, Holger

    2017-06-01

    Augmented Reality is a technique that enables users to interact with their physical environment through the overlay of digital information. While being researched for decades, more recently, Augmented Reality moved out of the research labs and into the field. While most of the applications are used sporadically and for one particular task only, current and future scenarios will provide a continuous and multi-purpose user experience. Therefore, in this paper, we present the concept of Pervasive Augmented Reality, aiming to provide such an experience by sensing the user's current context and adapting the AR system based on the changing requirements and constraints. We present a taxonomy for Pervasive Augmented Reality and context-aware Augmented Reality, which classifies context sources and context targets relevant for implementing such a context-aware, continuous Augmented Reality experience. We further summarize existing approaches that contribute towards Pervasive Augmented Reality. Based our taxonomy and survey, we identify challenges for future research directions in Pervasive Augmented Reality.

  13. Experimental study on power augmentation of Savonius rotor; Savonius gata fusha no shutsuryoku zokyo ni kansuru jikkenteki kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Sato, S; Kikuchi, K; Ushiyama, I [Ashikaga Institute of Technology, Tochigi (Japan)

    1997-11-25

    Wind power now being used is mostly for power generation, and the power generating rotor is represented by the horizontal propeller type. The vertical type, such as Savonius rotor which uses drag force, may be used for special purposes. The Savonius rotor has been used for water pumping-up and ventilation for its characteristics of low rotational speed and high torque. The authors have proposed, based on the data collected by operating a wind mill of 10W, a method for reducing resistance by deflecting wind flowing onto the return bucket to augment drag force, in an attempt to make the system more functional. The Savonius rotor is equipped with a semi-cylindrical cover, and guide and side plates, to follow their effects. It is found that these plates work to augment power without needing expansion of sweeping area. 4 refs., 12 figs.

  14. ARLearn: augmented reality meets augmented virtuality

    NARCIS (Netherlands)

    Ternier, Stefaan; Klemke, Roland; Kalz, Marco; Van Ulzen, Patricia; Specht, Marcus

    2012-01-01

    Ternier, S., Klemke, R., Kalz, M., Van Ulzen, P., & Specht, M. (2012). ARLearn: augmented reality meets augmented virtuality [Special issue]. Journal of Universal Computer Science - Technology for learning across physical and virtual spaces, 18(15), 2143-2164.

  15. Usefulness of the pterion plate in frontotemporal craniotomy

    International Nuclear Information System (INIS)

    Goto, Akiko; Aoki, Yoshinori; Kano, Toshiyuki

    2008-01-01

    The objective of this study was to evaluate the usefulness of the pterion plate in preventing depression of the lateral side of the orbita after frontotemporal craniotomy. Forty patients who underwent frontotemporal craniotomy at our facility were studied: 20 received pterion plates during surgery (pterion plate group) and 20 did not (non-pterion plate group). In all patients, postoperative bone window CT was used to confirm the presence or absence of a depression (≥5 mm) on the lateral side of the orbita. Patient satisfaction was assessed by a questionnaire. Depression of the lateral side of the orbita on postoperative bone window CT was noted in none of the subjects in the pterion plate group and in 12 (60%) of the subjects in the non-pterion plate group (p<0.01). Patient satisfaction was higher in the pterion plate than in the non-pterion plate group (p<0.01). Findings from bone window CT and the questionnaire indicate that the pterion plate is effective in preventing postoperative depression of the lateral side of the orbita during frontotemporal craniotomy. (author)

  16. Human glans penis augmentation using injectable hyaluronic acid gel.

    Science.gov (United States)

    Kim, J J; Kwak, T I; Jeon, B G; Cheon, J; Moon, D G

    2003-12-01

    Although augmentation phalloplasty is not an established procedure, some patients still need enlargement of their penis. Current penile augmentation is girth enhancement of penile body by dermofat graft. We performed this study to identify the efficacy and the patient's satisfaction of human glans penis augmentation with injectable hyaluronic acid gel. In 100 patients of subjective small penis (Group I) and 87 patients of small glans after dermofat graft (Group II), 2 cm(3) of hyaluronic acid gel was injected into the glans penis, subcutaneously. At 1 y after injection, changes of glandular diameter were measured by tapeline. Patient's visual estimation of glandular size (Gr 0-4) and patient's satisfaction (Grade (Gr) 0-4) were evaluated, respectively. Any adverse reactions were also evaluated. The mean age of patients was 42.2 (30-70) y in Group I and 42.13 (28-61) y in Group II. The maximal glandular circumference was significantly increased compared to basal circumference of 9.13+/-0.64 cm in Group I (Ppenis.

  17. Augmented postcard

    OpenAIRE

    Bernik , Aleš

    2012-01-01

    The aim of this thesis is the examination of augmented reality technology, which allows us mixing real and virtual elements. Augmented reality is a relatively new technology which is becoming more widespread, thanks to a fairly reasonable price of smart phones. Here we presents the types of augmented reality, the necessary technology and their advantages and disadvantages, its current use in applications, and software for building augmented reality applications. The thesis is mainly focuse...

  18. Patch-augmented rotator cuff repair: influence of the patch fixation technique on primary biomechanical stability.

    Science.gov (United States)

    Jung, Christian; Spreiter, Gregor; Audigé, Laurent; Ferguson, Stephen J; Flury, Matthias

    2016-05-01

    There is an ongoing debate about the potential of patch augmentation to improve biomechanical stability and healing associated with rotator cuff repair. The biomechanical properties of three different patch-augmented rotator cuff repair techniques were assessed in vitro and compared with a standard repair. Dermal collagen patch augmentation may increase the primary stability and strength of the repaired tendon in vitro, depending on the technique used for patch application. Forty cadaveric sheep shoulders with dissected infraspinatus tendons were randomized into four groups (n = 10/group) for tendon repair using a knotless double-row suture anchor technique. A xenologous dermal extracellular matrix patch was used for augmentation in the three test groups using an "integrated", "cover", or "hybrid" technique. Tendons were preconditioned, cyclically loaded from 10 to 30 N at 1 Hz, and then loaded monotonically to failure. Biomechanical properties and the mode of failure were evaluated. Patch augmentation significantly increased the maximum load at failure by 61 % in the "cover" technique test group (225.8 N) and 51 % in the "hybrid" technique test group (211.4 N) compared with the non-augmented control group (140.2 N) (P ≤ 0.015). For the test group with "integrated" patch augmentation, the load at failure was 28 % lower (101.6 N) compared with the control group (P = 0.043). There was no significant difference in initial and linear stiffness among the four experimental groups. The most common mode of failure was tendon pullout. No anchor dislocation, patch disruption or knot breakage was observed. Additional patch augmentation with a collagen patch influences the biomechanical properties of a rotator cuff repair in a cadaveric sheep model. Primary repair stability can be significantly improved depending on the augmentation technique.

  19. "Combined Occlusion and Atropine Therapy" Versus "Augmented Part-Time Patching" in Children with Refractory/Residual Amblyopia: A Pilot Study.

    Science.gov (United States)

    Sachdeva, Virender; Mittal, Vaibhev; Gupta, Varun; Gunturu, Rekha; Kekunnaya, Ramesh; Chandrasekharan, Anjali; Chabblani, Preeti Patil; Rao, Harsha L

    2016-01-01

    To compare the efficacy of combined occlusion and atropine therapy (COAT) and augmented part-time patching for the treatment of unilateral refractory/residual amblyopia. This retrospective study evaluated children between 4 and 11 years with refractory/residual amblyopia who were treated with either additional atropine (COAT group) or increased hours of patching (augmented group). Data were collected on improvement in best-corrected visual acuity (BCVA; logarithm of the minimum angle of resolution [logMAR] units) at each follow-up visit. There were 19 children in the COAT group and 17 children in the augmented group. The baseline BCVA of the amblyopic eye was 0.79 ± 0.36 logMAR in the COAT group and 0.72 ± 0.26 logMAR in augmented group. Children were statistically significantly younger in the COAT group (6.4 ± 2.2 years) compared to the augmented group (8.6 ± 3.3 years, P = 0.02). The mean duration of follow-up was statistically significantly longer in the augmented group (20.2 COAT group; 13.9 months augmented group) (P = 0.03). Compliance was similar in both groups. LogMAR BCVA (adjusted for difference in age and baseline BCVA) was statistically significantly better in the COAT group (0.56 ± 0.04) compared to the augmented group (0.80 ± 0.04) at 3 months (P = 0.000); 6 months (COAT group, 0.50 ± 0.04 vs. augmented group, 0.74 ± 0.04; P = 0.04) and at 1 year (COAT group, 0.42 ± 0.04 vs. augmented group, 0.67 ± 0.04, P = 0.000). There was statistically significantly greater improvement in logMAR BCVA at 6 months in COAT group (0.26 ± 0.15) compared to the augmented group (0.02 ± 0.14), (P = 0.0002). Age, gender, pretreatment BCVA, duration of follow-up, or compliance to patching did not affect improvement in BCVA. COAT may result in greater improvement in BCVA than augmented part-time patching in children with unilateral residual/refractory amblyopia.

  20. Wave Augmented Diffuser for Centrifugal Compressor

    Science.gov (United States)

    Skoch, Gary J. (Inventor); Paxson, Daniel E. (Inventor)

    2001-01-01

    A wave augmented diffuser for a centrifugal compressor surrounds the outlet of an impeller that rotates on a drive shaft having an axis of rotation. The impeller brings flow in in an axial direction and imparts kinetic energy to the flow discharging it in radial and tangential directions. The flow is discharged into a plurality of circumferentially disposed wave chambers. The wave chambers are periodically opened and closed by a rotary valve such that the flow through the diffuser is unsteady. The valve includes a plurality of valve openings that are periodically brought into and out of fluid communication with the wave chambers. When the wave chambers are closed, a reflected compression wave moves upstream towards the diffuser bringing the flow into the wave chamber to rest. This action recovers the kinetic energy from the flow and limits any boundary layer growth. The flow is then discharged in an axial direction through an opening in the valve plate when the valve plate is rotated to an open position. The diffuser thus efficiently raises the static pressure of the fluid and discharges an axially directed flow at a radius that is predominantly below the maximum radius of the diffuser.

  1. Proximal humeral fractures: the role of calcium sulphate augmentation and extended deltoid splitting approach in internal fixation using locking plates.

    Science.gov (United States)

    Somasundaram, K; Huber, C P; Babu, V; Zadeh, H

    2013-04-01

    The aim of our study is to analyse the results of our surgical technique for the treatment of proximal humeral fractures and fracture dislocations using locking plates in conjunction with calcium sulphate bone-substitute augmentation and tuberosity repair using high-strength sutures. We used the extended deltoid-splitting approach for fracture patterns involving displacement of both lesser and greater tuberosities and for fracture-dislocations. Optimal surgical management of proximal humeral fractures remains controversial. Locking plates have become a popular method of fixation. However, failure of fixation may occur if they are used as the sole method of fixation in comminuted fractures, especially in osteopenic bone. We retrospectively analysed 22 proximal humeral fractures in 21 patients; 10 were male and 11 female with an average age of 64.6 years (range 37-77). Average follow-up was 24 months. Eleven of these fractures were exposed by the extended deltoid-splitting approach. Fractures were classified according to Neer and Hertel systems. Preoperative radiographs and computed tomography (CT) scans in three- and four-part fractures were done to assess the displacement and medial calcar length for predicting the humeral head vascularity. According to the Neer classification, there were five two-part, six three-part, five four-part fractures and six fracture-dislocations (two anterior and four posterior). Results were assessed clinically with disabilities of the arm, shoulder and hand (DASH) scores, modified Constant and Murley scores and serial postoperative radiographs. The mean DASH score was 16.18 and the modified Constant and Murley score was 64.04 at the last follow-up. Eighteen out of twenty-two cases achieved good clinical outcome. All the fractures united with no evidence of infection, failure of fixation, malunion, tuberosity failure, avascular necrosis or adverse reaction to calcium sulphate bone substitute. There was no evidence of axillary nerve

  2. [Cement augmentation on the spine : Biomechanical considerations].

    Science.gov (United States)

    Kolb, J P; Weiser, L; Kueny, R A; Huber, G; Rueger, J M; Lehmann, W

    2015-09-01

    Vertebral compression fractures are the most common osteoporotic fractures. Since the introduction of vertebroplasty and screw augmentation, the management of osteoporotic fractures has changed significantly. The biomechanical characteristics of the risk of adjacent fractures and novel treatment modalities for osteoporotic vertebral fractures, including pure cement augmentation by vertebroplasty, and cement augmentation of screws for posterior instrumentation, are explored. Eighteen human osteoporotic lumbar spines (L1-5) adjacent to vertebral bodies after vertebroplasty were tested in a servo-hydraulic machine. As augmentation compounds we used standard cement and a modified low-strength cement. Different anchoring pedicle screws were tested with and without cement augmentation in another cohort of human specimens with a simple pull-out test and a fatigue test that better reflects physiological conditions. Cement augmentation in the osteoporotic spine leads to greater biomechanical stability. However, change in vertebral stiffness resulted in alterations with the risk of adjacent fractures. By using a less firm cement compound, the risk of adjacent fractures is significantly reduced. Both screw augmentation techniques resulted in a significant increase in the withdrawal force compared with the group without cement. Augmentation using perforated screws showed the highest stability in the fatigue test. The augmentation of cement leads to a significant change in the biomechanical properties. Differences in the stability of adjacent vertebral bodies increase the risk of adjacent fractures, which could be mitigated by a modified cement compound with reduced strength. Screws that were specifically designed for cement application displayed greatest stability in the fatigue test.

  3. Biomechanical study: resistance comparison of posterior antiglide plate and lateral plate on synthetic bone models simulating Danis-Weber B malleolar fractures

    Directory of Open Access Journals (Sweden)

    Bruna Buscharino

    2013-06-01

    Full Text Available OBJECTIVE : The purpose of this study was to compare different positions of plates in lateral malleolar Danis-Weber B fractures on synthetic bone: a lateral plate and a posterior antiglide plate. METHODS : Short oblique fractures of distal fibula at the level of the syndesmosys were simulated with a fibular osteotomy in sixteen synthetic fibula bones (Synbone®. Eight fractures were fixed with lateral plating associated with an independent lag screw, and the other eight were fixed with posterior antiglide plating with a lag screw through the plate. A strain gage was installed at the center of each plate at the osteotomy site. Supination and external rotation forces were applied to each of the two groups at the bend. RESULTS : The lateral position plate group suffered more deformity in response to supination forces compared to the group with the posterior antiglide plate, but this result was not statistically significant. In the tests with external rotation forces, the posterior antiglide plating group had significantly higher resistance (p < 0.05. CONCLUSION : When subjected to external rotation forces, osteosynthesis with posterior antiglide plate models simulating type B fractures of the lateral malleolus of the ankle is more resistant than that of the neutralization plate.

  4. Patellar Tendon Repair Augmentation With a Knotless Suture Anchor Internal Brace: A Biomechanical Cadaveric Study.

    Science.gov (United States)

    Rothfeld, Alex; Pawlak, Amanda; Liebler, Stephenie A H; Morris, Michael; Paci, James M

    2018-04-01

    Patellar tendon repair with braided polyethylene suture alone is subject to knot slippage and failure. Several techniques to augment the primary repair have been described. Purpose/Hypothesis: The purpose was to evaluate a novel patellar tendon repair technique augmented with a knotless suture anchor internal brace with suture tape (SAIB). The hypothesis was that this technique would be biomechanically superior to a nonaugmented repair and equivalent to a standard augmentation with an 18-gauge steel wire. Controlled laboratory study. Midsubstance patellar tendon tears were created in 32 human cadaveric knees. Two comparison groups were created. Group 1 compared #2 supersuture repair without augmentation to #2 supersuture repair with SAIB augmentation. Group 2 compared #2 supersuture repair with an 18-gauge stainless steel cerclage wire augmentation to #2 supersuture repair with SAIB augmentation. The specimens were potted and biomechanically loaded on a materials testing machine. Yield load, maximum load, mode of failure, plastic displacement, elastic displacement, and total displacement were calculated for each sample. Standard statistical analysis was performed. There was a statistically significant increase in the mean ± SD yield load and maximum load in the SAIB augmentation group compared with supersuture alone (mean yield load: 646 ± 202 N vs 229 ± 60 N; mean maximum load: 868 ± 162 N vs 365 ± 54 N; P augmented repairs (mean yield load: 495 ± 213 N vs 566 ± 172 N; P = .476; mean maximum load: 737 ± 210 N vs 697 ± 130 N; P = .721). Patellar tendon repair augmented with SAIB is biomechanically superior to repair without augmentation and is equivalent to repair with augmentation with an 18-gauge stainless steel cerclage wire. This novel patellar tendon repair augmentation is equivalent to standard 18-gauge wire augmentation at time zero. It does not require a second surgery for removal, and it is biomechanically superior to primary repair alone.

  5. Labor Augmentation with Oxytocin Decreases Glutathione Level

    Directory of Open Access Journals (Sweden)

    Naomi Schneid-Kofman

    2009-01-01

    Full Text Available Objective. To compare oxidative stress following spontaneous vaginal delivery with that induced by Oxytocin augmented delivery. Methods. 98 women recruited prior to labor. 57 delivered spontaneously, while 41 received Oxytocin for augmentation of labor. Complicated deliveries and high-risk pregnancies were excluded. Informed consent was documented. Arterial cord blood gases, levels of Hematocrit, Hemoglobin, and Bilirubin were studied. Glutathione (GSH concentration was measured by a spectroscopic method. Plasma and red blood cell (RBC levels of Malondialdehyde indicated lipid peroxidation. RBC uptake of phenol red denoted cell penetrability. SPSS data analysis was used. Results. Cord blood GSH was significantly lower in the Oxytocin group (2.3±0.55 mM versus 2.55±0.55 mM, =.01. No differences were found in plasma or RBC levels of MDA or in uptake of Phenol red between the groups. Conclusion. Lower GSH levels following Oxytocin augmentation indicate an oxidative stress, though selected measures of oxidative stress demonstrate no cell damage.

  6. Augmented kinematic feedback from haptic virtual reality for dental skill acquisition.

    Science.gov (United States)

    Suebnukarn, Siriwan; Haddawy, Peter; Rhienmora, Phattanapon; Jittimanee, Pannapa; Viratket, Piyanuch

    2010-12-01

    We have developed a haptic virtual reality system for dental skill training. In this study we examined several kinds of kinematic information about the movement provided by the system supplement knowledge of results (KR) in dental skill acquisition. The kinematic variables examined involved force utilization (F) and mirror view (M). This created three experimental conditions that received augmented kinematic feedback (F, M, FM) and one control condition that did not (KR-only). Thirty-two dental students were randomly assigned to four groups. Their task was to perform access opening on the upper first molar with the haptic virtual reality system. An acquisition session consisted of two days of ten trials of practice in which augmented kinematic feedback was provided for the appropriate experimental conditions after each trial. One week after, a retention test consisting of two trials without augmented feedback was completed. The results showed that the augmented kinematic feedback groups had larger mean performance scores than the KR-only group in Day 1 of the acquisition and retention sessions (ANOVA, p0.05). The trends in acquisition and retention sessions suggest that the augmented kinematic feedback can enhance the performance earlier in the skill acquisition and retention sessions.

  7. Sternocleidomastoid flap augmentation of the pharyngeal closure after total laryngectomy.

    Science.gov (United States)

    Ibrahim, Sherif Gabr; Wahba, Basim Metwally; Elbatawi, Ahmed Mahmoud; Eltelety, Ahmad Mohamed

    2017-08-01

    The objective of the study was to evaluate the effect of sternocleidomastoid (SCM) flap augmentation of the pharyngeal closure after total laryngectomy on the incidence of pharyngocutaneous fistula (PCF). Thirty patients with T4a laryngeal carcinoma and none of them receiving primary radiotherapy previously were divided into two equal groups. Group A patients had SCM flap augmentation of the pharyngeal closure after total laryngectomy. Group B patients had the standard pharyngeal closure without augmentation. Both groups were followed up for 30 days postoperatively for the development of PCF. The use of the SCM added about extra 15 min to the surgical procedure in all patients (p laryngectomy. Three patients in each group developed PCF either early (10 days or less postoperatively) or late (more than 10 days but less than 30 days postoperatively). There was no statistically significant difference in the length of hospital stay between the two groups. The use of SCM flap did not reduce the incidence of PCF after total laryngectomy.

  8. Dilemma in pediatric mandible fractures: resorbable or metallic plates?

    Science.gov (United States)

    Taylan Filinte, Gaye; Akan, İsmail Mithat; Ayçiçek Çardak, Gülçin Nujen; Özkaya Mutlu, Özay; Aköz, Tayfun

    2015-12-01

    The aim of this study was to compare the efficiency of resorbable and metallic plates in open reduction and internal fixation of mandible fractures in children. Thirty-one patients (mean age, 8.05 years; range 20 months-14 years) were operated on various fractures of the mandible (26 [60.4%] symphysis- parasymphysis, 12 [27.9%] condylar-subcondylar fractures, 5 [11.6%] angulus and ramus fractures). Twelve patients were treated with resorbable plates and 19 patients with metallic plates. Mean follow-up time was 41 months (11-74 months) in the metallic hardware group and was 22 months (8-35 months) in the resorbable plate group. Both groups were investigated for primary bone healing, complications, number of operations, and mandibular growth. The results were discussed below. Both groups demonstrated primary bone healing. Minor complications were similar in both groups. The metallic group involved secondary operations for plate removal. Mandibular growth was satisfactory in both groups. Resorbable plates cost more than the metallic ones; however, when the secondary operations are included in the total cost, resorbable plates were favourable. As mandibular growth and complication parameters are similar in both groups, resorbable plates are favored due to avoidance of potential odontogenic injury, elimination of long-term foreign body retention and provision of adequate stability for rapid bone healing. However, learning curve and concerns for decreased stability against heavy forces of mastication accompanied with the resorbable plates when compared to the metallic ones should be kept in mind.

  9. Comparison of patients undergoing switching versus augmentation of antipsychotic medications during treatment for schizophrenia

    Directory of Open Access Journals (Sweden)

    Ascher-Svanum H

    2012-03-01

    Full Text Available Haya Ascher-Svanum, Alan JM Brnabic, Anthony H Lawson, Bruce J Kinon, Virginia L Stauffer, Peter D Feldman, Katarina KelinLilly Research Laboratories, Eli Lilly and Company, Lilly Corporate Center, Indianapolis, Indiana, USAAbstract: It is often difficult to determine whether a patient may best benefit by augmenting their current medication or switching them to another. This post-hoc analysis compares patients’ clinical and functional profiles at the time their antipsychotic medications were either switched or augmented. Adult outpatients receiving oral antipsychotic treatment for schizophrenia were assessed during a 12-month international observational study. Clinical and functional measures were assessed at the time of first treatment switch/augmentation (0–14 days prior and compared between Switched and Augmented patient groups. Due to low numbers of patients providing such data, interpretations are based on effect sizes. Data at the time of change were available for 87 patients: 53 Switched and 34 Augmented. Inadequate response was the primary reason for treatment change in both groups, whereas lack of adherence was more prevalent in the Switched group (26.4% vs 8.8%. Changes in clinical severity from study initiation to medication change were similar, as indicated by Clinical Global Impressions–Severity scores. However, physical and mental component scores of the 12-item Short-Form Health Survey improved in the Augmented group, but worsened in the Switched group. These findings suggest that the patient’s worsening or lack of meaningful improvement prompts clinicians to switch antipsychotic medications, whereas when patients show some improvement, clinicians may be more likely to try bolstering the improvements through augmentation. Current findings are consistent with physicians’ stated reasons for switching versus augmenting antipsychotics in the treatment of schizophrenia. Confirmation of these findings requires further research

  10. Mandibular reconstruction using a titanium plate: the impact of radiation therapy on plate preservation

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Janice K; Stern, Robin L; Robinson, Marilyn G; Bowers, Michael K; Kubo, Hideo D; Donald, Paul J; Rosenthal, Seth A; Fu, Karen K

    1995-06-15

    Purpose: To evaluate the soft tissue and bone tolerance of radiation therapy (RT) in patients undergoing radical composite resection and mandibular reconstruction using a bridging titanium plate with myocutaneous flap closure. Methods and Materials: From 1990 to 1994, 47 patients with primary or recurrent oral cavity or oropharyngeal carcinomas were treated with radical composite resection and mandibular reconstruction using a bridging titanium plate with myocutaneous flap closure. Eleven patients received no RT (no RT), 10 patients received RT greater than 10 months from the time of surgery (remote RT), and 26 patients received RT within 12 weeks of surgery (perioperative RT). The radiation dose to the reconstructed mandible ranged from 45 to 75 Gy (median 63 Gy). The effect of the titanium plate on the radiation dose was measured using film dosimetry and soft tissue and bone-equivalent materials. The median follow-up was 17 months (range: 3-50 months). Results: Late complications included four patients with osteomyelitis or necrosis, two plate exposures requiring flap revision, one chronic infection, two cases of chronic pain, two fistulae, and one case of trismus and malocclusion. The crude incidence of late complications by treatment was: (a) no RT: 3 of 11 patients (27%); (b) remote RT: 2 of 10 patients (20%); and (c) perioperative RT: 9 of 26 patients (35%). One patient in the no-RT group lost the plate due to chronic pain. Five patients in the perioperative RT group also had plate loss, four due to osteomyelitis and/or necrosis, and one due to pain related to a recurrent tumor. No patients in the remote RT group had plate loss. The actuarial prosthesis preservation rate at 2 years was 88% for the no RT, 100% for the remote RT, and 57% for the perioperative RT groups (p = 0.05). Phantom dose measurements showed that for parallel opposed 6 MV photon beams, there was no significant increase in the dose proximal or distal to the plate in either a soft tissue- or

  11. Novel Augmentation Strategies in Major Depression

    DEFF Research Database (Denmark)

    Martiny, Klaus

    2017-01-01

    open psychiatric wards. Only a few patients were re-cruited through advertisements (in the PEMF and Chronos studies). Inclusion criteria Inclusion criteria were major depression according to the DSM-IV, including a depressive episode as part of a bipolar disorder. For the PEMF study, treatment...... The results from the Pindolol study showed that pindolol did not augment the effect of venlafaxine for the whole sample. However, for those patients classified as slow metabolizers, based on their O-desmethylvenlafaxine/venlafaxine ratio (ODV/V), pindolol did augment the antidepressant effect. For patients...... classified as fast metabolizers, pindolol worsened the outcome. This interaction between ODV/V ratio and treatment group was statistically significant (p = 0.01). Results from the PEMF study The results from the PEMF Study showed that treatment with active versus sham PEMF augmented the effect of the ongoing...

  12. An Efficiency Analysis of Augmented Reality Marker Recognition Algorithm

    Directory of Open Access Journals (Sweden)

    Kurpytė Dovilė

    2014-05-01

    Full Text Available The article reports on the investigation of augmented reality system which is designed for identification and augmentation of 100 different square markers. Marker recognition efficiency was investigated by rotating markers along x and y axis directions in range from −90° to 90°. Virtual simulations of four environments were developed: a an intense source of light, b an intense source of light falling from the left side, c the non-intensive light source falling from the left side, d equally falling shadows. The graphics were created using the OpenGL graphics computer hardware interface; image processing was programmed in C++ language using OpenCV, while augmented reality was developed in Java programming language using NyARToolKit. The obtained results demonstrate that augmented reality marker recognition algorithm is accurate and reliable in the case of changing lighting conditions and rotational angles - only 4 % markers were unidentified. Assessment of marker recognition efficiency let to propose marker classification strategy in order to use it for grouping various markers into distinct markers’ groups possessing similar recognition properties.

  13. Plate removal following orthognathic surgery.

    Science.gov (United States)

    Little, Mhairi; Langford, Richard Julian; Bhanji, Adam; Farr, David

    2015-11-01

    The objectives of this study are to determine the removal rates of orthognathic plates used during orthognathic surgery at James Cook University Hospital and describe the reasons for plate removal. 202 consecutive orthognathic cases were identified between July 2004 and July 2012. Demographics and procedure details were collected for these patients. Patients from this group who returned to theatre for plate removal between July 2004 and November 2012 were identified and their notes were analysed for data including reason for plate removal, age, smoking status, sex and time to plate removal. 3.2% of plates were removed with proportionally more plates removed from the mandible than the maxilla. 10.4% of patients required removal of one or more plate. Most plates were removed within the first post-operative year. The commonest reasons for plate removal were plate exposure and infection. The plate removal rates in our study are comparable to those seen in the literature. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  14. Secondary Breast Augmentation.

    Science.gov (United States)

    Brown, Mitchell H; Somogyi, Ron B; Aggarwal, Shagun

    2016-07-01

    After studying this article, the participant should be able to: 1. Assess common clinical problems in the secondary breast augmentation patient. 2. Describe a treatment plan to correct the most common complications of breast augmentation. 3. Provide surgical and nonsurgical options for managing complications of breast augmentation. 4. Decrease the incidence of future complications through accurate assessment, preoperative planning, and precise surgical technique. Breast augmentation has been increasing steadily in popularity over the past three decades. Many of these patients present with secondary problems or complications following their primary breast augmentation. Two of the most common complications are capsular contracture and implant malposition. Familiarity and comfort with the assessment and management of these complications is necessary for all plastic surgeons. An up-to-date understanding of current devices and techniques may decrease the need to manage future complications from the current cohort of breast augmentation patients.

  15. Fiia: A Model-Based Approach to Engineering Collaborative Augmented Reality

    Science.gov (United States)

    Wolfe, Christopher; Smith, J. David; Phillips, W. Greg; Graham, T. C. Nicholas

    Augmented reality systems often involve collaboration among groups of people. While there are numerous toolkits that aid the development of such augmented reality groupware systems (e.g., ARToolkit and Groupkit), there remains an enormous gap between the specification of an AR groupware application and its implementation. In this chapter, we present Fiia, a toolkit which simplifies the development of collaborative AR applications. Developers specify the structure of their applications using the Fiia modeling language, which abstracts details of networking and provides high-level support for specifying adapters between the physical and virtual world. The Fiia.Net runtime system then maps this conceptual model to a runtime implementation. We illustrate Fiia via Raptor, an augmented reality application used to help small groups collaboratively prototype video games.

  16. Cadmium plating replacements

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, M.J.; Groshart, E.C.

    1995-03-01

    The Boeing Company has been searching for replacements to cadmium plate. Two alloy plating systems seem close to meeting the needs of a cadmium replacement. The two alloys, zinc-nickel and tin-zinc are from alloy plating baths; both baths are neutral pH. The alloys meet the requirements for salt fog corrosion resistance, and both alloys excel as a paint base. Currently, tests are being performed on standard fasteners to compare zinc-nickel and tin-zinc on threaded hardware where cadmium is heavily used. The Hydrogen embrittlement propensity of the zinc-nickel bath has been tested, and just beginning for the tin-zinc bath. Another area of interest is the electrical properties on aluminum for tin-zinc and will be discussed. The zinc-nickel alloy plating bath is in production in Boeing Commercial Airplane Group for non-critical low strength steels. The outlook is promising that these two coatings will help The Boeing Company significantly reduce its dependence on cadmium plating.

  17. The effects of error augmentation on learning to walk on a narrow balance beam.

    Science.gov (United States)

    Domingo, Antoinette; Ferris, Daniel P

    2010-10-01

    Error augmentation during training has been proposed as a means to facilitate motor learning due to the human nervous system's reliance on performance errors to shape motor commands. We studied the effects of error augmentation on short-term learning of walking on a balance beam to determine whether it had beneficial effects on motor performance. Four groups of able-bodied subjects walked on a treadmill-mounted balance beam (2.5-cm wide) before and after 30 min of training. During training, two groups walked on the beam with a destabilization device that augmented error (Medium and High Destabilization groups). A third group walked on a narrower beam (1.27-cm) to augment error (Narrow). The fourth group practiced walking on the 2.5-cm balance beam (Wide). Subjects in the Wide group had significantly greater improvements after training than the error augmentation groups. The High Destabilization group had significantly less performance gains than the Narrow group in spite of similar failures per minute during training. In a follow-up experiment, a fifth group of subjects (Assisted) practiced with a device that greatly reduced catastrophic errors (i.e., stepping off the beam) but maintained similar pelvic movement variability. Performance gains were significantly greater in the Wide group than the Assisted group, indicating that catastrophic errors were important for short-term learning. We conclude that increasing errors during practice via destabilization and a narrower balance beam did not improve short-term learning of beam walking. In addition, the presence of qualitatively catastrophic errors seems to improve short-term learning of walking balance.

  18. Visual error augmentation enhances learning in three dimensions.

    Science.gov (United States)

    Sharp, Ian; Huang, Felix; Patton, James

    2011-09-02

    Because recent preliminary evidence points to the use of Error augmentation (EA) for motor learning enhancements, we visually enhanced deviations from a straight line path while subjects practiced a sensorimotor reversal task, similar to laparoscopic surgery. Our study asked 10 healthy subjects in two groups to perform targeted reaching in a simulated virtual reality environment, where the transformation of the hand position matrix was a complete reversal--rotated 180 degrees about an arbitrary axis (hence 2 of the 3 coordinates are reversed). Our data showed that after 500 practice trials, error-augmented-trained subjects reached the desired targets more quickly and with lower error (differences of 0.4 seconds and 0.5 cm Maximum Perpendicular Trajectory deviation) when compared to the control group. Furthermore, the manner in which subjects practiced was influenced by the error augmentation, resulting in more continuous motions for this group and smaller errors. Even with the extreme sensory discordance of a reversal, these data further support that distorted reality can promote more complete adaptation/learning when compared to regular training. Lastly, upon removing the flip all subjects quickly returned to baseline rapidly within 6 trials.

  19. Visual error augmentation enhances learning in three dimensions

    Directory of Open Access Journals (Sweden)

    Huang Felix

    2011-09-01

    Full Text Available Abstract Because recent preliminary evidence points to the use of Error augmentation (EA for motor learning enhancements, we visually enhanced deviations from a straight line path while subjects practiced a sensorimotor reversal task, similar to laparoscopic surgery. Our study asked 10 healthy subjects in two groups to perform targeted reaching in a simulated virtual reality environment, where the transformation of the hand position matrix was a complete reversal--rotated 180 degrees about an arbitrary axis (hence 2 of the 3 coordinates are reversed. Our data showed that after 500 practice trials, error-augmented-trained subjects reached the desired targets more quickly and with lower error (differences of 0.4 seconds and 0.5 cm Maximum Perpendicular Trajectory deviation when compared to the control group. Furthermore, the manner in which subjects practiced was influenced by the error augmentation, resulting in more continuous motions for this group and smaller errors. Even with the extreme sensory discordance of a reversal, these data further support that distorted reality can promote more complete adaptation/learning when compared to regular training. Lastly, upon removing the flip all subjects quickly returned to baseline rapidly within 6 trials.

  20. “Combined Occlusion and Atropine Therapy” Versus “Augmented Part-Time Patching” in Children with Refractory/Residual Amblyopia: A Pilot Study

    Science.gov (United States)

    Sachdeva, Virender; Mittal, Vaibhev; Gupta, Varun; Gunturu, Rekha; Kekunnaya, Ramesh; Chandrasekharan, Anjali; Chabblani, Preeti Patil; Rao, Harsha L.

    2016-01-01

    Purpose: To compare the efficacy of combined occlusion and atropine therapy (COAT) and augmented part-time patching for the treatment of unilateral refractory/residual amblyopia. Methodology: This retrospective study evaluated children between 4 and 11 years with refractory/residual amblyopia who were treated with either additional atropine (COAT group) or increased hours of patching (augmented group). Data were collected on improvement in best-corrected visual acuity (BCVA; logarithm of the minimum angle of resolution [logMAR] units) at each follow-up visit. Results: There were 19 children in the COAT group and 17 children in the augmented group. The baseline BCVA of the amblyopic eye was 0.79 ± 0.36 logMAR in the COAT group and 0.72 ± 0.26 logMAR in augmented group. Children were statistically significantly younger in the COAT group (6.4 ± 2.2 years) compared to the augmented group (8.6 ± 3.3 years, P = 0.02). The mean duration of follow-up was statistically significantly longer in the augmented group (20.2 COAT group; 13.9 months augmented group) (P = 0.03). Compliance was similar in both groups. LogMAR BCVA (adjusted for difference in age and baseline BCVA) was statistically significantly better in the COAT group (0.56 ± 0.04) compared to the augmented group (0.80 ± 0.04) at 3 months (P = 0.000); 6 months (COAT group, 0.50 ± 0.04 vs. augmented group, 0.74 ± 0.04; P = 0.04) and at 1 year (COAT group, 0.42 ± 0.04 vs. augmented group, 0.67 ± 0.04, P = 0.000). There was statistically significantly greater improvement in logMAR BCVA at 6 months in COAT group (0.26 ± 0.15) compared to the augmented group (0.02 ± 0.14), (P = 0.0002). Age, gender, pretreatment BCVA, duration of follow-up, or compliance to patching did not affect improvement in BCVA. Conclusions: COAT may result in greater improvement in BCVA than augmented part-time patching in children with unilateral residual/refractory amblyopia. PMID:27162453

  1. [Comparison of novel infrared heating plates and conventional warm water plates for piglets' creep areas in farrowing pens].

    Science.gov (United States)

    Strauch-Sürken, L; Wendt, M

    2015-01-01

    On a conventionally managed piglet-producing farm, novel infrared (IR) heating plates for piglets in the farrowing pens were tested for their suitability and compared with common warm-water (WW) heating plates. In total, 134 litters (summer n = 82, winter n = 52) were investigated, which were housed on IR or WW heating plates, respectively, with or without an extra cover plate (groups 1-4). To determine the influence of the different heat sources, the wound healing after castration and tail docking, the umbilical regression and the weight gain of the piglets were investigated. Additionally, the lying behavior of the piglets and the position of the sows' udder at the time of farrowing were examined with regard to the heating plates. Furthermore, the energy consumption and costs were compared. The piglets housed on IR heating plates displayed better wound healing after castration and tail docking than the piglets housed on WW plates. The best results were obtained in piglets kept on IR heating plates with an extra cover plate. In addition, significant benefits were demonstrated for the usage of IR heating plates regarding umbilical regression. The piglets kept on IR heating plates had a slightly better weight gain in summer, whereas there were no differences between groups during winter. The lying behavior in the creep areas was similar in all groups. In general, with increasing age the percentage of time piglets spent in the lying position on the plates decreased. The percentage of time lying on the plates was higher in winter than in summer. At farrowing, 74.6% of all investigated sows directed their udder towards the heating plates. With the IR heating plates, this behavior occurred significantly more often. The energy consumption (kWh) per litter was significantly lower for the IR heating plates (electric power) both in winter and summer in comparison with the WW plates (gas). The energy costs were comparable in summer, but were higher for the IR heating plates

  2. [Application of the anatomic plate and trapezoid plate in comminuted intertrochanteric fracture combined with trochanteric coronal position fracture: a controlled clinical trial].

    Science.gov (United States)

    Zhen, Ping; Liu, Xing-Yan; Gao, Ming-Xuan; Tian, Qi

    2010-05-01

    To investigate the therapeutic effect and operative characteristic of the anatomic plate and trapezoid plate for treament of the comminuted intertrochanteric fracture combined with trochanteric coronal position fracture. From Jan. 1998 to Mar. 2007, 57 patients suffered from comminuted intertrochanteric fracture combined with trochanteric coronal position fracture were randomly divided into two groups, 21 patients in trapezoid plate group were treated with the trapezoid compression plate, included 11 males and 10 females with an average age of 41.8 years; and 36 patients in anatomic plate group were treated with the anatomic plate, included 17 males and 19 females with an average age of 42.1 years. All of the 57 fractures were A3 type according to AO classification. The functions of hip joints were evaluated according to the Harris hip functional standard score. All 57 patients were followed-up for 5 months to 9 years and 3 months with an average of 4.8 years. The healing time of the fractures was from 8 to 20 weeks with an average of 12.8 weeks. The results of Harris scoring showed the pain scores of the anatomic plate group were higher than that of the trapezoid plate group (P 0.05). In unstable comminuted intertrochanteric fracture combined with trochanteric coronal position fracture, the lateral wall of trochanteric is often destroyed. The anatomic plate and the trapeziod compression plate can provide effective internal fixation, while many othere internal fixation methods were limited in this kind of fracture. As compared with the anatomic plate fixation, the trapezoid compression plate fixation of comminuted intertrochanteric fracture combined with trochanteric coronal position fracture have several advantages, such as fewer complications, faster union of fracture and earlier recovery of joint functions.

  3. The Effects of Augmented Reality-based Otago Exercise on Balance, Gait, and Falls Efficacy of Elderly Women.

    Science.gov (United States)

    Yoo, Ha-Na; Chung, Eunjung; Lee, Byoung-Hee

    2013-07-01

    [Purpose] The purpose of this study was to determine the effects of augmented reality-based Otago exercise on balance, gait, and falls efficacy of elderly women. [Subjects] The subjects were 21 elderly women, who were randomly divided into two groups: an augmented reality-based Otago exercise group of 10 subjects and an Otago exercise group of 11 subjects. [Methods] All subjects were evaluated for balance (Berg Balance Scale, BBS), gait parameters (velocity, cadence, step length, and stride length), and falls efficacy. Within 12 weeks, Otago exercise for muscle strengthening and balance training was conducted three times, for a period of 60 minutes each, and subjects in the experimental group performed augmented reality-based Otago exercise. [Results] Following intervention, the augmented reality-based Otago exercise group showed significant increases in BBS, velocity, cadence, step length (right side), stride length (right side and left side) and falls efficacy. [Conclusion] The results of this study suggest the feasibility and suitability of this augmented reality-based Otago exercise for elderly women.

  4. Using selective chromogenic plates to optimize isolation of group B Streptococcus in pregnant women

    Directory of Open Access Journals (Sweden)

    Romano Mattei

    2014-03-01

    Full Text Available Group B Streptococcus (GBS remains the leading cause of severe bacterial infections (sepsis, meningitis, pneumonia in neonates. We compared the detection of GBS from recto-vaginal swabs on blood agar and two chromogenic media and evaluated their antibiotic susceptibility. A total of 1351 swabs were taken from pregnant women at 35-37 weeks of gestation. Following enrichment in Todd Hewitt broth + nalidixic acid and colistin, the samples were plated on Columbia CNA agar (CNA, chromID Strepto B agar (STRB and Granada Agar (GRAN, respectively. GBS were found in 22.4% of recto-vaginal swabs from pregnant women. Sensitivity, specificity, positive and negative predictive values of GBS detection were 88%, 88%, 81% and 96% for CNA, 99%, 97%, 90% and 99% for STRB and 94%, 99%, 98% e 99% for GRAN; Cohen’s k index concordances for CNA, STREB and GRAN were 0.68, 0.92 and 0.96, respectively. All isolates were susceptible to penicillin, whereas resistances of erythromycin and clindamycin were 40% and 42%, respectively. To conclude, selective broth enrichment combined with chromogenic plates is recommended for GBS screening in pregnant women.

  5. Investigation of vertebral ''end plate sclerosis''

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.W. [Dept. of Rehabilitation Sciences, Hong Kong Polytechnic Univ., Hung Hom (Hong Kong); Mathie, A.G.; Jackson, J.E. [Diagnostic Radiology, Royal Postgraduate Medical School, Hammersmith Hospital, London (United Kingdom); Hughes, S.P.F. [Div. of Surgery, Anaesthetics and Intensive Care, London (United Kingdom)

    2001-08-01

    To evaluate the association between vertebral ''end plate sclerosis'' and neck pain. A retrospective study was carried out of lateral cervical spine radiographs with a Picture Archive and Communication System (PACS). Two hundred patients' files were randomly assessed, comprising four equal groups, A to D. The mean ages of the patients were 62{+-}7.4 years, 61{+-}7.5 years, 40{+-}5.6 years and 23{+-}5.6 years respectively. In group A, all patients had symptoms of neck pain and a radiographic diagnosis of ''end plate sclerosis'' of the cervical spine. In groups B to D, asymptomatic patients were recruited and their age groups were 50-69, 30-49 and 10-29 years respectively. Using the PACS, the radiographic density and the sagittal diameter, thickness and area of the end plates at the C5 level were measured. Results and conclusions: No significant differences were found in the radiographic density of the end plates either between the symptomatic and asymptomatic groups (groups A and B), or between different age groups (groups B, C and D). A significant increase in end plate area and thickness was found, however, in both group B (P<0.005) and group C (P<0.01) in comparison with group D. This indicates that the extent of end plate sclerosis increases with age. Our results suggest that the radiographic density of cervical vertebral end plates correlates neither with neck pain nor with increasing age. The radiological sign of ''end plate sclerosis'' may be over-reported, further limiting its value in the assessment of patients with cervical spondylosis. (orig.)

  6. Effects of Creatine Monohydrate Augmentation on Brain Metabolic and Network Outcome Measures in Women With Major Depressive Disorder.

    Science.gov (United States)

    Yoon, Sujung; Kim, Jieun E; Hwang, Jaeuk; Kim, Tae-Suk; Kang, Hee Jin; Namgung, Eun; Ban, Soonhyun; Oh, Subin; Yang, Jeongwon; Renshaw, Perry F; Lyoo, In Kyoon

    2016-09-15

    Creatine monohydrate (creatine) augmentation has the potential to accelerate the clinical responses to and enhance the overall efficacy of selective serotonin reuptake inhibitor treatment in women with major depressive disorder (MDD). Although it has been suggested that creatine augmentation may involve the restoration of brain energy metabolism, the mechanisms underlying its antidepressant efficacy are unknown. In a randomized, double-blind, placebo-controlled trial, 52 women with MDD were assigned to receive either creatine augmentation or placebo augmentation of escitalopram; 34 subjects participated in multimodal neuroimaging assessments at baseline and week 8. Age-matched healthy women (n = 39) were also assessed twice at the same intervals. Metabolic and network outcomes were measured for changes in prefrontal N-acetylaspartate and changes in rich club hub connections of the structural brain network using proton magnetic resonance spectroscopy and diffusion tensor imaging, respectively. We found MDD-related metabolic and network dysfunction at baseline. Improvement in depressive symptoms was greater in patients receiving creatine augmentation relative to placebo augmentation. After 8 weeks of treatment, prefrontal N-acetylaspartate levels increased significantly in the creatine augmentation group compared with the placebo augmentation group. Increment in rich club hub connections was also greater in the creatine augmentation group than in the placebo augmentation group. N-acetylaspartate levels and rich club connections increased after creatine augmentation of selective serotonin reuptake inhibitor treatment. Effects of creatine administration on brain energy metabolism and network organization may partly underlie its efficacy in treating women with MDD. Copyright © 2016 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  7. Healing of extraction sockets and augmented alveolar defects following 1-year treatment with bisphosphonate.

    Science.gov (United States)

    Khojasteh, Arash; Behnia, Hossein; Morad, Golnaz; Dashti, Seyedeh Ghazaleh; Dehghan, Mohammad Mehdi; Shahab, Shahriyar; Abbas, Fatemeh Mashhadi

    2013-01-01

    To assess the effect of bisphosphonates on healing of extraction sockets and augmented alveolar defects, 12 adult female mongrel dogs were assigned to 2 experimental groups and a control group. The experimental groups received oral alendronate (ALN, 3.5 mg/kg/wk) or IV pamidronate (PAM, 1 mg/kg/wk) for 12 months. Animals were randomly tested for serum C-terminal telopeptide of collagen I (CTx). The right first and second premolars were extracted. After 8 weeks, extraction sites were evaluated for healing. Subsequently, 3-wall defects were created in ridges and filled with human mineralized cortical particulate bone. Two months post-augmentation, animals were sacrificed and mandibles were collected for cone-beam computed tomography (CBCT) and histomorphometric appraisal. The obtained data were compared using 1-way ANOVA test. CTx test results in both experimental groups were comparable (alveolar bone in the PAM group and the upper rim of the alveoli in the ALN group. Histologically, bone sequestra from the PAM group demonstrated empty osteocyte lacunae, while in the ALN group areas of necrotic bone along with evidence of active bone remodeling was distinguished. Eight weeks post-augmentation, the experimental groups showed no evidence of bone formation in the augmented area, while bone formation ratio was measured to be 18.32% in the control group. The mean amount of pixel intensity calculated from the CBCT images of the ALN, PAM, and control group was 113.69 ± 11.04, 124.94 ± 4.72, and 113.69 ± 6.63, respectively. Pixel intensity in PAM-treated group was significantly higher than both other groups. This study demonstrated that 1-year treatment with ALN/PAM was associated with impairment of post-extraction and post-augmentation bone healing in dogs.

  8. ServAR: An augmented reality tool to guide the serving of food.

    Science.gov (United States)

    Rollo, Megan E; Bucher, Tamara; Smith, Shamus P; Collins, Clare E

    2017-05-12

    Accurate estimation of food portion size is a difficult task. Visual cues are important mediators of portion size and therefore technology-based aids may assist consumers when serving and estimating food portions. The current study evaluated the usability and impact on estimation error of standard food servings of a novel augmented reality food serving aid, ServAR. Participants were randomised into one of three groups: 1) no information/aid (control); 2) verbal information on standard serving sizes; or 3) ServAR, an aid which overlayed virtual food servings over a plate using a tablet computer. Participants were asked to estimate the standard serving sizes of nine foods (broccoli, carrots, cauliflower, green beans, kidney beans, potato, pasta, rice, and sweetcorn) using validated food replicas. Wilcoxon signed-rank tests compared median served weights of each food to reference standard serving size weights. Percentage error was used to compare the estimation of serving size accuracy between the three groups. All participants also performed a usability test using the ServAR tool to guide the serving of one randomly selected food. Ninety adults (78.9% female; a mean (95%CI) age 25.8 (24.9-26.7) years; BMI 24.2 (23.2-25.2) kg/m 2 ) completed the study. The median servings were significantly different to the reference portions for five foods in the ServAR group, compared to eight foods in the information only group and seven foods for the control group. The cumulative proportion of total estimations per group within ±10%, ±25% and ±50% of the reference portion was greater for those using ServAR (30.7, 65.2 and 90.7%; respectively), compared to the information only group (19.6, 47.4 and 77.4%) and control group (10.0, 33.7 and 68.9%). Participants generally found the ServAR tool easy to use and agreed that it showed potential to support optimal portion size selection. However, some refinements to the ServAR tool are required to improve the user experience. Use of the

  9. Biocompatibility and Biocorrosion of Hydroxyapatite-Coated Magnesium Plate: Animal Experiment

    Directory of Open Access Journals (Sweden)

    Ho-Kyung Lim

    2017-09-01

    Full Text Available Magnesium (Mg has the advantage of being resorbed in vivo, but its resorption rate is difficult to control. With uncontrolled resorption, Magnesium as a bone fixation material has minimal clinical value. During resorption not only is the strength rapidly weakened, but rapid formation of metabolite also occurs. In order to overcome these disadvantages, hydroxyapatite (HA surface coating of pure magnesium plate was attempted in this study. Magnesium plates were inserted above the frontal bone of Sprague-Dawley rats in both the control group (Bare-Mg group and the experimental group (HA-Mg group. The presence of inflammation, infection, hydrogen gas formation, wound dehiscence, and/or plate exposure was observed, blood tests were performed, and the resorption rate and tensile strength of the retrieved metal plates were measured. The HA-Mg group showed no gas formation or plate exposure until week 12. However, the Bare-Mg group showed consistent gas formation and plate exposure beginning in week 2. WBC (White Blood Cell, BUN (Blood Urea Nitrogen, Creatinine, and serum magnesium concentration levels were within normal range in both groups. AST (Aspartate Aminotransferase and ALT (Alanine Aminotransferase values, however, were above normal range in some animals of both groups. The HA-Mg group showed statistically significant advantage in resistance to degradation compared to the Bare-Mg group in weeks 2, 4, 6, 8, and 12. Degradation of HA-Mg plates proceeded after week 12. Coating magnesium plates with hydroxyapatite may be a viable method to maintain their strength long enough to allow bony healing and to control the resorption rate during the initial period.

  10. Fracture prevention by prophylactic femoroplasty of the proximal femur--metallic compared with cemented augmentation.

    Science.gov (United States)

    Springorum, Hans-Robert; Gebauer, Matthias; Mehrl, Alexander; Stark, Olaf; Craiovan, Benjamin; Püschel, Klaus; Amling, Michael; Grifka, Joachim; Beckmann, Johannes

    2014-07-01

    To compare 2 different femoral neck augmentation techniques at improving the mechanical strength of the femoral neck. Twenty pairs of human cadaveric femora were randomly divided into 2 groups. In 1 group, the femora were augmented with a steel spiral; the other group with the cemented technique. The untreated contralateral side served as an intraindividual control. Fracture strength was evaluated using an established biomechanical testing scenario mimicking a fall on the greater trochanter (Hayes fall). The peak load to failure was significantly higher in the steel spiral group (P = 0.0024) and in the cemented group (P = 0.001) compared with the intraindividual controls. The peak load to failure showed a median of 3167 N (1825-5230 N) in the spiral group and 2485 N (1066-4395 N) in the spiral control group. The peak load to failure in the cemented group was 3698 N (SD ± 1249 N) compared with 2763 N (SD ± 1335 N) in the cement control group. Furthermore, fracture displacement was clearly reduced in the steel spiral group. Femoral augmentations using steel spirals or cement-based femoroplasty are technically feasible procedures. Our results demonstrate that a prophylactic reinforced proximal femur has higher strength when compared with the untreated contralateral limb. Prophylactic augmentation has potential to become an auxiliary treatment option to protect the osteoporotic proximal femur against fracture.

  11. A locking compression plate versus the gold-standard non-locking plate with lag screw for first metatarsophalangeal fusion: A biomechanical comparison.

    Science.gov (United States)

    Mandell, Daniel; Karbassi, John; Zhou, Hanbing; Burroughs, Brian; Aurigemma, Philip; Patel, Abhay R

    2018-03-01

    The treatment of end-stage first metatarso-phalangeal joint (MTP) arthritis has been arthrodesis. A dorsal non-locking plate with a lag screw has been the standard traditional fixation method. This study compares the biomechanical strength of a locking compression plate (LCP) with and without internal compression versus this known gold standard. In group 1, six matched pairs of cadaver great toes were used to compare the standard non-locking dorsal plate and 3.5mm lag screw to an anatomic locking compression plate in which a lag screw was utilized rather than the internal compression features of the plate. In group 2, another six matched pairs of cadaver great toes were used to compare the gold standard to the locking compression plate, utilizing the plate's internal compression feature instead of a lag screw. A material testing system (MTS) machine applied loads to the MTP joints and measured displacement and stiffness of the constructs. The stiffness of the constructs (Young's modulus) was calculated from the force-displacement curves, and the displacement was measured. The locking compression plate group that used the compression features of the plate, without the lag screw, had less joint displacement and higher stiffness than control (p<0.05). The same plating construct in which a lag screw was used rather than internal compression of the plate was found to be stiffer than the control (p<0.05), but displacement was not statistically significant. The results suggest that a locking compression plate alone provides the stiffest construct for a first MTP joint fusion. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. AUGMENTED REALITY

    DEFF Research Database (Denmark)

    Skov, Kirsten; Bahn, Anne Louise

    2017-01-01

    Projektets grundlæggende idé er udvikling af visuel, æstetisk læring med Augmented Reality, hvor intentionen er at bidrage med konkrete undersøgelser og udforskning af begrebet Augmented Reality – herunder koblingen mellem det analoge og digitale i forhold til læring, multimodalitet og it...

  13. Tracking for Outdoor Mobile Augmented Reality: Further development of the Zion Augmented Reality Application

    OpenAIRE

    Strand, Tor Egil Riegels

    2008-01-01

    This report deals with providing tracking to an outdoor mobile augmented reality system and the Zion Augmented Reality Application. ZionARA is meant to display a virtual recreation of a 13th century castle on the site it once stood through an augmented reality Head Mounted Display. Mobile outdoor augmented/mixed reality puts special demands on what kind of equipment is practical. After briefly evaluating the different existing tracking methods, a solution based on GPS and an augmented inertia...

  14. Bibliography on augmentation of convective heat and mass transfer

    International Nuclear Information System (INIS)

    Bergles, A.E.; Webb, R.L.; Junkhan, G.H.; Jensen, M.K.

    1979-05-01

    Heat transfer augmentation has developed into a major specialty area in heat transfer research and development. A bibliography of world literature on augmentation is presented. The literature is classified into passive augmentation techniques, which require no external power, and active techniques, which do require external power. The fourteen techniques are grouped in terms of their application to the various modes of heat transfer. Mass transfer is included for completeness. Key words are included with each citation for technique/mode identification. The total number of publications cited is 1,967, including 75 surveys of various techniques and 42 papers on performance evaluation of passive techniques. Patents are not included as they will be the subject of a future topical report

  15. [Polymethylmethacrylate augmentation of bone cement-injectable cannulated pedicle screws for the treatment of degenerative lumbar diseases with osteoporosis].

    Science.gov (United States)

    Sun, H L; Li, C D; Yang, Z C; Yi, X D; Liu, H; Lu, H L; Li, H; Wang, Y

    2016-12-18

    To describe the application of polymethylmethacrylate augmentation of bone cement-injectable cannulated pedicle screws for the treatment of degenerative lumbar diseases with osteoporosis. Observation group included 14 cases of degenerative lumbar diseases with osteoporosis received polymethylmethacrylate augmentation of bone cement-injectable cannulated pedicle screws from November 2014 to July 2015, control group included 12 cases of degenerative lumbar diseases with osteoporosis received polymethylmethacrylate augmentation with traditional pedicle screws.The operation time, blood loss, number of pedicle screws and number of augmented pedicle screws in the two groups were compared. The bone cement leakage and pulmonary bone cement embolism in the two groups were also compared. The fusion rate and pedicle screws loosening by lumbar X ray and dynamic X ray were evaluated. The clinical results were assessed by visual analog scale (VAS) of pain on lumbar and lower limbers, lumbar Japanese Orthopaedic Association scores (JOA), Prolo functional scores and Oswestry disability (ODI) scores. Differences of operation time and blood loss in the two groups were not statistically significant. The average number of pedicle screws was 9.9±4.7 and the average number of augmented pedicle screws was 5.9±2.6 in observation group while the average number of pedicle screws was 7.1±2.8 and the average number of augmented pedicle screws was 3.0±1.9 in control group. The ratio of augmented pedicle screws was higher in observation group than in control group (0.69±0.30 vs.0.47±0.30,Pdegenerative lumbar diseases with osteoporosis was effective, with simple working processes and lower risk of bone cement leakage. The short-term clinical result was good.

  16. Understanding augmented reality concepts and applications

    CERN Document Server

    Craig, Alan B

    2013-01-01

    Augmented reality is not a technology. Augmented reality is a medium. Likewise, a book on augmented reality that only addresses the technology that is required to support the medium of augmented reality falls far short of providing the background that is needed to produce, or critically consume augmented reality applications. One reads a book. One watches a movie. One experiences augmented reality. Understanding Augmented Reality addresses the elements that are required to create compelling augmented reality experiences. The technology that supports

  17. Implant Material, Type of Fixation at the Shaft, and Position of Plate Modify Biomechanics of Distal Femur Plate Osteosynthesis.

    Science.gov (United States)

    Kandemir, Utku; Augat, Peter; Konowalczyk, Stefanie; Wipf, Felix; von Oldenburg, Geert; Schmidt, Ulf

    2017-08-01

    To investigate whether (1) the type of fixation at the shaft (hybrid vs. locking), (2) the position of the plate (offset vs. contact) and (3) the implant material has a significant effect on (a) construct stiffness and (b) fatigue life in a distal femur extraarticular comminuted fracture model using the same design of distal femur periarticular locking plate. An extraarticular severely comminuted distal femoral fracture pattern (OTA/AO 33-A3) was simulated using artificial bone substitutes. Ten-hole distal lateral femur locking plates were used for fixation per the recommended surgical technique. At the distal metaphyseal fragment, all possible locking screws were placed. For the proximal diaphyseal fragment, different types of screws were used to create 4 different fixation constructs: (1) stainless steel hybrid (SSH), (2) stainless steel locked (SSL), (3) titanium locked (TiL), and (4) stainless steel locked with 5-mm offset at the diaphysis (SSLO). Six specimens of each construct configuration were tested. First, each specimen was nondestructively loaded axially to determine the stiffness. Then, each specimen was cyclically loaded with increasing load levels until failure. Construct Stiffness: The fixation construct with a stainless steel plate and hybrid fixation (SSH) had the highest stiffness followed by the construct with a stainless steel plate and locking screws (SSL) and were not statistically different from each other. Offset placement (SSLO) and using a titanium implant (TiL) significantly reduced construct stiffness. Fatigue Failure: The stainless steel with hybrid fixation group (SSH) withstood the most number of cycles to failure and higher loads, followed by the stainless steel plate and locking screw group (SSL), stainless steel plate with locking screws and offset group (SSLO), and the titanium plate and locking screws group (TiL) consecutively. Offset placement (SSLO) as well as using a titanium implant (TiL) reduced cycles to failure. Using the

  18. Effects of design on cost of flat-plate solar photovoltaic arrays for terrestrial central station power applications

    Science.gov (United States)

    Tsou, P.; Stolte, W.

    1978-01-01

    The paper examines the impact of module and array designs on the balance-of-plant costs for flat-plate terrestrial central station power applications. Consideration is given to the following types of arrays: horizontal, tandem, augmented, tilt adjusted, and E-W tracking. The life-cycle cost of a 20-year plant life serves as the costing criteria for making design and cost tradeoffs. A tailored code of accounts is developed for determining consistent photovoltaic power plant costs and providing credible photovoltaic system cost baselines for flat-plate module and array designs by costing several varying array design approaches.

  19. Jointly Optimize Data Augmentation and Network Training: Adversarial Data Augmentation in Human Pose Estimation

    OpenAIRE

    Peng, Xi; Tang, Zhiqiang; Yang, Fei; Feris, Rogerio; Metaxas, Dimitris

    2018-01-01

    Random data augmentation is a critical technique to avoid overfitting in training deep neural network models. However, data augmentation and network training are usually treated as two isolated processes, limiting the effectiveness of network training. Why not jointly optimize the two? We propose adversarial data augmentation to address this limitation. The main idea is to design an augmentation network (generator) that competes against a target network (discriminator) by generating `hard' au...

  20. Confronting an augmented reality

    Directory of Open Access Journals (Sweden)

    John Hedberg

    2012-08-01

    Full Text Available How can educators make use of augmented reality technologies and practices to enhance learning and why would we want to embrace such technologies anyway? How can an augmented reality help a learner confront, interpret and ultimately comprehend reality itself? In this article, we seek to initiate a discussion that focuses on these questions, and suggest that they be used as drivers for research into effective educational applications of augmented reality. We discuss how multi-modal, sensorial augmentation of reality links to existing theories of education and learning, focusing on ideas of cognitive dissonance and the confrontation of new realities implied by exposure to new and varied perspectives. We also discuss connections with broader debates brought on by the social and cultural changes wrought by the increased digitalisation of our lives, especially the concept of the extended mind. Rather than offer a prescription for augmentation, our intention is to throw open debate and to provoke deep thinking about what interacting with and creating an augmented reality might mean for both teacher and learner.

  1. Comparative evaluation of 2.3 mm locking plate system vs conventional 2.0 mm non locking plate system for mandibular condyle fracture fixation: a seven year retrospective study.

    Science.gov (United States)

    Zhang, J; Wang, X; Wu, R-H; Zhuang, Q-W; Gu, Q P; Meng, J

    2015-01-01

    This retrospective study evaluated the efficacy of a 2.3 mm locking plate/screw system compared with a 2.0-mm non-locking plate/screw system in fixation of isolated non comminuted mandibular condyle fractures. Surgical records of 101 patients who received either a 2.3 mm locking plate (group A, n = 51) or 2.0 mm non locking plate (group B, n = 50) were analyzed. All patients were followed up to a minimum of 6 months postoperatively and evaluated for hardware related complications, occlusal stability, need for and duration of MMF and mandibular functional results. Four complications occurred in the locking group and eighteen in the non locking group with complication rates equalling 8% and 36% respectively. When comparing the overall results according to plates used, the χ2 test showed a statistically significant difference between the locking and non locking plates (p Mandibular condyle fractures treated with a 2.3 mm locking plate exhibited stable osteosynthesis, were associated with minimal complications and resulted in acceptable mandibular range of motion compared with a 2.0 mm non locking plate.

  2. Rotator cuff repair healing influenced by platelet-rich plasma construct augmentation.

    Science.gov (United States)

    Barber, F Alan; Hrnack, Scott A; Snyder, Stephen J; Hapa, Onur

    2011-08-01

    To assess the effect of platelet-rich plasma fibrin matrix (PRPFM) construct augmentation on postoperative tendon healing as determined by magnetic resonance imaging (MRI) and clinical outcome of arthroscopic rotator cuff repair. A comparative series of patients undergoing arthroscopic rotator cuff repair was studied. Two matched groups of patients (20 each) were included: rotator cuff repairs without PRPFM augmentation (group 1) and rotator cuff repairs augmented with 2 sutured platelet-rich plasma (PRP) constructs (group 2). A single-row cuff repair to the normal footprint without tension or marrow vents was performed by a single surgeon. Postoperative rehabilitation was held constant. Postoperative MRI scans were used to evaluate rotator cuff healing. Outcome measures included American Shoulder and Elbow Surgeons, Rowe, Single Assessment Numeric Evaluation, Simple Shoulder Test, and Constant scores. We followed up 40 patients (2 matched groups with 20 patients each) with a mean age of 57 years (range, 44 to 69 years) for a mean of 31 months (range, 24 to 44 months). Postoperative MRI studies showed persistent full-thickness tendon defects in 60% of controls (12 of 20) and 30% of PRPFM-augmented repairs (6 of 20) (P = .03). Of the control group tears measuring less than 3 cm in anteroposterior length, 50% (7 of 14) healed fully, whereas 86% of the PRPFM group tears measuring less than 3 cm in anteroposterior length (12 of 14) healed fully (P rotator cuff tendon repair resulted in lower retear rates identified on MRI than repairs without the constructs. Other than the Rowe scores, there was no postoperative clinical difference by use of standard outcome measures. Level III, case-control study. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  3. Adjacent segment pathology following anterior decompression and fusion using cage and plate for the treatment of degenerative cervical spinal diseases.

    Science.gov (United States)

    Song, Kyung-Jin; Choi, Byung-Wan; Kim, Jong-Kil

    2014-12-01

    Retrospective study. To analyze the incidence and prevalence of clinical adjacent segment pathology (CASP) following anterior decompression and fusion with cage and plate augmentation for degenerative cervical diseases. No long-term data on the use of cage and plate augmentation have been reported. The study population consisted of 231 patients who underwent anterior cervical discectomy and fusion (ACDF) with cage and plate for degenerative cervical spinal disease. The incidence and prevalence of CASP was determined by using the Kaplan-Meier survival analysis. To analyze the factors that influence CASP, data on preoperative and postoperative sagittal alignment, spinal canal diameter, the distance between the plate and adjacent disc, extent of fusion level, and the presence or absence of adjacent segment degenerative changes by imaging studies were evaluated. CASP occurred in 15 of the cases, of which 9 required additional surgery. At 8-year follow-up, the average yearly incidence was 1.1%. The rate of disease-free survival based on Kaplan-Meier survival analysis was 93.6% at 5 years and 90.2% at 8 years. No statistically significant differences in CASP incidence based on radiological analysis were observed. Significantly high incidence of CASP was observed in the presence of increased adjacent segment degenerative changes (pdegenerative cervical disease is associated with a lower incidence in CSAP by 1.1% per year, and the extent of preoperative adjacent segment degenerative changes has been shown as a risk factor for CASP.

  4. Maxillary sinus augmentation

    Directory of Open Access Journals (Sweden)

    A B Tarun Kumar

    2015-01-01

    Full Text Available Placing dental implants in the maxillary posterior region can be both challenging and un-nerving for a regular implant dentist who is not well versed with advanced surgical procedures. It is vital for a general dentist to understand the fundamentals of bone grafting the maxillary sinus if he/she is really committed to providing the best health care for their patients. The dental practice is seeing an increasing group of patients who are living longer, and this group of older baby boomers often has an edentulous posterior maxilla either unilateral or bilateral. When edentulous, the posterior maxilla more likely has diminished bone height, which does not allow for the placement of dental implants without creating additional bone. Through grafting the maxillary sinus, bone of ideal quality can be created (allowing for placement of dental implants, which offer many advantages over other tooth replacement modalities. The sinus graft offers the dental patient a predictable procedure of regenerating lost osseous structure in the posterior maxilla. This offers the patient many advantages for long-term success. If dentists understand these concepts, they can better educate their patients and guide them to have the procedure performed. This article outlines bone grafting of the maxillary sinus for the purpose of placing dental implants. This review will help the readers to understand the intricacies of sinus augmentation. They can relate their patient's condition with the available literature and chalk out the best treatment plan for the patient, especially by using indirect sinus augmentation procedures which are less invasive and highly successful if done using prescribed technique.

  5. Bibliography on augmentation of convective heat and mass transfer-II

    Energy Technology Data Exchange (ETDEWEB)

    Bergles, A.E.; Nirmalan, V.; Junkhan, G.H.; Webb, R.L.

    1983-12-01

    Heat transfer augmentation has developed into a major specialty area in heat transfer research and development. This report presents and updated bibliography of world literature on augmentation. The literature is classified into passive augmentation techniques, which require no external power, and active techniques, which do require external power. The fifteen techniques are grouped in terms of their applications to the various modes of heat transfer. Mass transfer is included for completeness. Key words are included with each citation for technique/mode identification. The total number of publications cited is 3045, including 135 surveys of various techniques and 86 papers on performance evaluation of passive techniques. Patents are not included, as they are the subject of a separate bibliographic report.

  6. Alpha-1-antitrypsin augmentation therapy in deficient individuals enrolled in the Alpha-1 Foundation DNA and Tissue Bank

    Directory of Open Access Journals (Sweden)

    Adriano R Tonelli

    2009-12-01

    Full Text Available Adriano R Tonelli1, Farshid Rouhani1, Ning Li2, Pam Schreck1, Mark L Brantly11Alpha-1 Research Program, Division of Pulmonary, Critical Care and Sleep Medicine, Department of Internal Medicine, 2Department of Epidemiology and Biostatistics, University of Florida, Gainesville, Florida, USAIntroduction: Intravenous augmentation therapy with purified intravenous alpha-1 antitrypsin replaces the deficient protein and is the only currently approved treatment for alpha-1 antitrypsin deficiency (AATD related lung disease. While augmentation therapy has been available for more than 20 years, there are a limited number of studies evaluating the effect of augmentation on lung function.Material and methods: We examined the decline in forced expiratory volume in one second (FEV1 in patients enrolled in the Alpha-1 Foundation DNA and Tissue Bank in relation to the use or not of alpha-1 antitrypsin augmentation therapy. For the purpose of our analysis we included 164 patients with AATD and PI ZZ genotype.Results: Mean age of the patients was 60 years, 52% were females, 94% were white and 78% ex-smokers. The mean FEV1 at baseline was 1.7 L and the mean FEV1 % of predicted was 51.3%. The mean follow-up time was 41.7 months. A total of 124 (76% patients received augmentation therapy (augmented group while 40 patients (24% did not received it (non-augmented group. When adjusted by age at baseline, sex, smoking status, baseline FEV1 % of predicted, the mean overall change in FEV1 was 47.6 mL/year, favoring the augmented group (?FEV1 10.6 ± 21.4 mL/year in comparison with the non-augmented group (?FEV1 −36.96 ± 12.1 mL/year (P = 0.05. Beneficial ?FEV1 were observed in ex-smokers and the group with initial FEV1 % of predicted of <50%. No differences were observed in mortality.Conclusions: In conclusion, augmentation therapy improves lung function in subjects with AATD when adjusted by age, gender, smoking status and baseline FEV1 % of predicted. The beneficial

  7. Augmented reality in bone tumour resection

    Science.gov (United States)

    Park, Y. K.; Gupta, S.; Yoon, C.; Han, I.; Kim, H-S.; Choi, H.; Hong, J.

    2017-01-01

    Objectives We evaluated the accuracy of augmented reality (AR)-based navigation assistance through simulation of bone tumours in a pig femur model. Methods We developed an AR-based navigation system for bone tumour resection, which could be used on a tablet PC. To simulate a bone tumour in the pig femur, a cortical window was made in the diaphysis and bone cement was inserted. A total of 133 pig femurs were used and tumour resection was simulated with AR-assisted resection (164 resection in 82 femurs, half by an orthropaedic oncology expert and half by an orthopaedic resident) and resection with the conventional method (82 resection in 41 femurs). In the conventional group, resection was performed after measuring the distance from the edge of the condyle to the expected resection margin with a ruler as per routine clinical practice. Results The mean error of 164 resections in 82 femurs in the AR group was 1.71 mm (0 to 6). The mean error of 82 resections in 41 femurs in the conventional resection group was 2.64 mm (0 to 11) (p Augmented reality in bone tumour resection: An experimental study. Bone Joint Res 2017;6:137–143. PMID:28258117

  8. Closed External Fixation for Failing or Failed Femoral Shaft Plating in a Developing Country.

    Science.gov (United States)

    Aliakbar, Adil; Witwit, Ibrahim; Al-Algawy, Alaa A Hussein

    2017-08-01

    Femoral shaft fractures are one of the common injuries that is treated by open reduction, with internal fixation by plate and screws or intramedullary nailing, which can achieve a high union rate. To evaluate the outcome of using closed external fixation to augment a failing plate; with signs of screw loosening and increasing bone/plate gap; a failed plate; broken plate; screws completely out of bone with redisplacement of fracture. A retrospective study on 18 patients, aged between 17-42 years, who presented between 6-18 weeks after initial surgical fixation, with pain, difficulty in limb function, deformity and abnormal movement at fracture site, was done. X-Rays showed plating failure with acceptable amount of callus, which unfortunately had refractured. Cases associated with infection and no radiological evidence of callus formation were excluded from this study. Closed reduction was done by manipulation, then fracture fixation by AO external fixator. The patients were encouraged for full weight bearing as early as possible with dynamization later on. Of the 18 patients who underwent external fixation after close reduction, 15 cases showed bone healing in a period between 11-18 weeks (mean of 14.27 weeks) with good alignment (Radiologically). Removal of external fixator was done followed by physical therapy thereafter. Closed external fixation for treatment of failing or failed femoral plating, achieves good success rate and has less complications, is a short time procedure, especially in a hospital with limited resources.

  9. Comparison of conventional reconstruction plate versus direct metal laser sintering plate: an in vitro mechanical characteristics study.

    Science.gov (United States)

    Xie, Pusheng; Ouyang, Hanbin; Deng, Yuping; Yang, Yang; Xu, Jing; Huang, Wenhua

    2017-09-02

    Additive manufacturing (AM) technology has helped to achieve several advances in the medical field, particularly as far as fabrication of implants is concerned. But the application of direct metal laser sintering (DMLS) bone plate is quite limited due to the indeterminate mechanical property. The purposes of this study were to characterize the biomechanical properties of the polished DMLS reconstruction plate and to compare these with the properties of commonly applied implants and to find whether the mechanical performance of DMLS plate meets the requirements for clinical application. In this study, we fabricated two groups of plates by DMLS and computer numerical control (CNC) techniques. After that, we polished all samples and investigated their roughness, components, hardness, static bending, and torsional performance. Moreover, cyclic bending tests and fractographic analysis were conducted. Statistical comparisons of the group by means of monotonic test data were made, and a qualitative comparison was performed to assess failures in fatigue. We found no differences in surface roughness or components after polishing, but the DMLS plate hardness is 7.42% (p direct application of these AM instruments in the operating room requires further validation including animal and clinical experiment.

  10. Can oxytocin augmentation modify the risk of epidural analgesia by maternal age in cesarean sections?

    Science.gov (United States)

    Rossen, Janne; Klungsøyr, Kari; Albrechtsen, Susanne; Løkkegård, Ellen; Rasmussen, Steen; Bergholt, Thomas; Skjeldestad, Finn E

    2018-03-07

    Maternal age is an established risk factor for cesarean section; epidural analgesia and oxytocin augmentation may modify this association. We investigated the effects and interactions of oxytocin augmentation, epidural analgesia and maternal age on the risk of cesarean section. In all, 416 386 nulliparous women with spontaneous onset of labor, ≥37 weeks of gestation and singleton infants with a cephalic presentation during 2000-2011 from Norway and Denmark were included [Ten-group classification system (Robson) group 1]. In this case-control study the main exposure was maternal age; epidural analgesia, oxytocin augmentation, birthweight and time period were explanatory variables. Chi-square test and logistic regression were used to estimate associations and interactions. The cesarean section rate increased consistently with advancing maternal age, both overall and in strata of epidural analgesia and oxytocin augmentation. We observed strong interactions between maternal age, oxytocin augmentation and epidural analgesia for the risk of cesarean section. Women with epidural analgesia generally had a reduced adjusted odds ratio when oxytocin was used compared with when it was not used. In Norway, this applied to all maternal age groups but in Denmark only for women ≥30 years. Among women without epidural, oxytocin augmentation was associated with an increased odds ratio for cesarean section in Denmark, whereas no difference was observed in Norway. Oxytocin augmentation in nulliparous women with epidural analgesia is associated with a reduced risk of cesarean section in labor with spontaneous onset. © 2018 Nordic Federation of Societies of Obstetrics and Gynecology.

  11. Create Your Plate

    Medline Plus

    Full Text Available ... tool is not to scale because of the differences in types of vegetables. When creating your plate ... function (data) { $('#survey-errors').remove(); $('.survey-form .form-group .survey-alert-wrap').remove(); if (data.submitSurveyResponse.success == ' ...

  12. Cement augmentation of implants--no general cure in osteoporotic fracture treatment. A biomechanical study on non-displaced femoral neck fractures.

    Science.gov (United States)

    Hofmann-Fliri, Ladina; Nicolino, Tomas I; Barla, Jorge; Gueorguiev, Boyko; Richards, R Geoff; Blauth, Michael; Windolf, Markus

    2016-02-01

    Femoral neck fractures in the elderly are a common problem in orthopedics. Augmentation of screw fixation with bone cement can provide better stability of implants and lower the risk of secondary displacement. This study aimed to investigate whether cement augmentation of three cannulated screws in non-displaced femoral neck fractures could increase implant fixation. A femoral neck fracture was simulated in six paired human cadaveric femora and stabilized with three 7.3 mm cannulated screws. Pairs were divided into two groups: conventional instrumentation versus additional cement augmentation of screw tips with 2 ml TraumacemV+ each. Biomechanical testing was performed by applying cyclic axial load until failure. Failure cycles, axial head displacement, screw angle changes, telescoping and screw cut-out were evaluated. Failure (15 mm actuator displacement) occurred in the augmented group at 12,500 cycles (± 2,480) compared to 15,625 cycles (± 4,215) in the non-augmented group (p = 0.041). When comparing 3 mm vertical displacement of the head no significant difference (p = 0.72) was detected between the survival curves of the two groups. At 8,500 load-cycles (early onset failure) the augmented group demonstrated a change in screw angle of 2.85° (± 0.84) compared to 1.15° (± 0.93) in the non-augmented group (p = 0.013). The results showed no biomechanical advantage with respect to secondary displacement following augmentation of three cannulated screws in a non-displaced femoral neck fracture. Consequently, the indication for cement augmentation to enhance implant anchorage in osteoporotic bone has to be considered carefully taking into account fracture type, implant selection and biomechanical surrounding. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  13. Dorsal bridge plating or transarticular screws for Lisfranc fracture dislocations.

    Science.gov (United States)

    Kirzner, N; Zotov, P; Goldbloom, D; Curry, H; Bedi, H

    2018-04-01

    Aims The aim of this retrospective study was to compare the functional and radiological outcomes of bridge plating, screw fixation, and a combination of both methods for the treatment of Lisfranc fracture dislocations. Patients and Methods A total of 108 patients were treated for a Lisfranc fracture dislocation over a period of nine years. Of these, 38 underwent transarticular screw fixation, 45 dorsal bridge plating, and 25 a combination technique. Injuries were assessed preoperatively according to the Myerson classification system. The outcome measures included the American Orthopaedic Foot and Ankle Society (AOFAS) score, the validated Manchester Oxford Foot Questionnaire (MOXFQ) functional tool, and the radiological Wilppula classification of anatomical reduction. Results Significantly better functional outcomes were seen in the bridge plate group. These patients had a mean AOFAS score of 82.5 points, compared with 71.0 for the screw group and 63.3 for the combination group (p bridge plate group, 38.1 in the screw group, and 45.5 in the combination group (p bridge plating have better functional and radiological outcomes than those treated with transarticular screws or a combination technique. Cite this article: Bone Joint J 2018;100-B:468-74.

  14. A comparison of breast stimulation and intravenous oxytocin for the augmentation of labor.

    Science.gov (United States)

    Curtis, P; Resnick, J C; Evens, S; Thompson, C J

    1999-06-01

    Breast stimulation to augment labor has been used for centuries in tribal societies and by midwives. In recent years it has been shown to be effective in ripening the cervix, inducing labor, and as an alternative to oxytocin for the contraction stress test. This study compared the effectiveness of breast stimulation with oxytocin infusion in augmenting labor. Women admitted to the labor ward were eligible for the study if they had inadequate labor with premature rupture of the membranes and met inclusion criteria. They were assigned to oxytocin augmentation or breast stimulation (manual or pump), and were switched to oxytocin in the event of method failure. Outcomes included time to delivery, intervention to delivery, proportion of spontaneous deliveries, and Apgar scores. One hundred participants were needed in each arm of the study to demonstrate a 2- to 3-hour difference in delivery time, with a power of 80 percent. Analysis was performed on 79 women, of whom 49 were in the breast stimulation group and 30 in the oxytocin group. Sixty-five percent of the participants failed breast stimulation and were switched to oxytocin infusion. Although augmentation start to delivery was shorter for the oxytocin group (p < 0.001), no differences in total labor time occurred between the groups. Nulliparas receiving breast stimulation had more spontaneous (relative risk 1.7, p = 0.04), and fewer instrumental deliveries than those receiving oxytocin (relative risk 0.2, p = 0.02). No significant differences in adverse fetal outcomes occurred between the study groups. The small number of participants and a variety of problems with the conduct of the study prevented the formulation of reliable conclusions from the results. However, the study provided important insights into the feasibility and problems of developing a high-quality randomized trial of augmentation by breast stimulation.

  15. Long-term psychological sequelae of augmentation mammoplasty ...

    African Journals Online (AJOL)

    A request for elective surgery for augmentation mammoplasty (AM) is often associated with underlying psychopathology and high expectations of a positive psychological outcome. This study was designed to ascertain the long-term psychological sequelae of AM in a group of patients who were reassessed 3 years or more ...

  16. Modeling particulate removal in plate-plate and wire-plate electrostatic precipitators

    Directory of Open Access Journals (Sweden)

    S Ramechecandane

    2016-09-01

    Full Text Available The present study is concerned with the modeling of electrically charged particles in a model plate-plate and a single wire-plate electrostatic precipitator (ESP. The particle concentration distributions for both a plate-plate and a wire-plate ESP are calculated using a modified drift flux model. Numerical investigations are performed using the modified drift flux model for particle number concentration, in addition to the RNG k - ε model for the mean turbulent flow field and the Poisson equation for the electric field. The proposed model and the outlined methodology for coupling the flow field, electric field, charging kinetics and particle concentration is applied to two model precipitators that are truly representative of a wide class of commercialized ESPs. The present investigation is quite different from the earlier studies as it does not make assumptions like a homogeneous electric field or an infinite turbulent diffusivity. The electric field calculated is a strong function of position and controls the migration velocity of particles. Hence, the proposed model can be implemented in a flow solver to obtain a full-fledged solution for any kind of ESP with no limitations on the particle number concentration, as encountered in a Lagrangian approach. The effect of turbulent diffusivity on particle number concentration in a plate-plate ESP is investigated in detail and the results obtained are compared with available experimental data. Similarly, the effect of particle size/diameter and applied electric potential on the accumulative collection performance in the case of a wire-plate ESP is studied and the results obtained are compared with available numerical data. The numerical results obtained using the modified drift flux model for both the plate-plate and wire-plate ESP are in close agreement with available experimental and numerical data.

  17. Psychotherapy augmentation through preconscious priming

    Directory of Open Access Journals (Sweden)

    Francois eBorgeat

    2013-03-01

    Full Text Available Objective: To test the hypothesis that repeated preconscious (masked priming of personalized positive cognitions could augment cognitive change and facilitate achievement of patients’ goals following a therapy.Methods: Twenty social phobic patients (13 women completed a 36 weeks study beginning by 12 weeks of group behavioural therapy. After the therapy, they received 6 weeks of preconscious priming and 6 weeks of a control procedure in a randomized cross-over design. The Priming condition involved listening twice daily with a passive attitude to a recording of individualized formulations of appropriate cognitions and attitudes masked by music. The Control condition involved listening to an indistinguishable recording where the formulations had been replaced by random numbers. Changes in social cognitions were measured by the Social Interaction Self Statements Test (SISST.Results: Patients improved following therapy. The Priming procedure was associated with increased positive cognitions and decreased negative cognitions on the SISST while the Control procedure was not. The Priming procedure induced more cognitive change when applied immediately after the group therapy. Conclusion: An effect of priming was observed on social phobia related cognitions in the expected direction. This self administered addition to a therapy could be seen as an augmentation strategy.

  18. Mobile Augmented Reality Applications

    OpenAIRE

    Prochazka, David; Stencl, Michael; Popelka, Ondrej; Stastny, Jiri

    2011-01-01

    Augmented reality have undergone considerable improvement in past years. Many special techniques and hardware devices were developed, but the crucial breakthrough came with the spread of intelligent mobile phones. This enabled mass spread of augmented reality applications. However mobile devices have limited hardware capabilities, which narrows down the methods usable for scene analysis. In this article we propose an augmented reality application which is using cloud computing to enable using...

  19. Torsional Growth Modulation of Long Bones by Oblique Plating in a Rabbit Model.

    Science.gov (United States)

    Lazarus, David E; Farnsworth, Christine L; Jeffords, Megan E; Marino, Nikolas; Hallare, Jericho; Edmonds, Eric W

    2018-02-01

    There is evidence that oblique tension band plating can affect torsional growth in long bones. This study sought to determine if the torsional growth could be modulated based on the angles of the tension band plating and whether or not oblique plating affected overall longitudinal growth. New Zealand White rabbits (10.5 wk old) had one screw placed on the metaphyseal side and one on the epiphyseal side of both medial and lateral sides of the right knee distal femoral physis. The sham group (n=5) included screw placement only. For the plate group (n=13), unlocked plates, angled from 0 to 76 degrees, connected the screws and spanned the physis. Radiographs were taken at biweekly intervals. After 6 weeks of growth, hindlimbs were harvested and microCT scans performed. Femoral length, distances between screw heads and angle between the plates were measured on radiographs. Femoral length differences were compared between groups. Femoral version was measured from 3D microCT. Plate angle changes were correlated to the difference in femoral version between limbs using Pearson correlation (significance was set to P<0.05 for all comparisons). Femur length difference between the contralateral and the operative side was significantly greater in the plate group compared with the sham group over time (P=0.049). Medial and lateral screw distances changed significantly more in the sham group than the plate group on both sides (P<0.001). A greater initial angle between plates resulted in a greater change in the angle between plates (P<0.001). Significant correlations were found between right-left side femoral version differences and initial plate angle (P=0.003) and plate angle change (P=0.014). The torsional effect of oblique plating seems to correlate with the amount of initial plate angle, with an additional, not negligible, longitudinal growth effect. Placing plates at given angles across open physes may result in predictable changes in bone torsion allowing for a safer and

  20. Augmenting Clozapine With Sertindole

    DEFF Research Database (Denmark)

    Nielsen, Jimmi; Emborg, Charlotte; Gydesen, Susanne

    2012-01-01

    Clozapine augmentation with antipsychotic drugs is widely used despite sparse evidence supporting this strategy. Sertindole is a nonsedating atypical antipsychotic drug with low affinity for cholinergic receptors, which makes it potentially suitable for augmentation of clozapine. The study design...... glucose, lipids, and electrocardiogram. Clozapine augmentation with sertindole was not superior to placebo regarding total score or subscale score of the Positive and Negative Syndrome Scale, Clinical Global Impression, World Health Organization Quality of Life Brief, or Drug Attitude Inventory....... No increased adverse effects compared with placebo were found. Four patients randomized to sertindole experienced a significant worsening of psychosis, and 2 of them required psychiatric admission. Metabolic parameters were unchanged during the study, but augmentation of clozapine with sertindole...

  1. Comparative study of W-shaped angular plate and reconstruction plate in treating posterior wall fractures of the acetabulum.

    Directory of Open Access Journals (Sweden)

    Qi Zhang

    Full Text Available OBJECTIVE: This study aims to assess the medium-term results of the reconstruction of posterior wall fractures using a W-shaped acetabular angular plate (WAAP compared to those fixed using a reconstruction plate. METHODS: Between July 2006 and March 2009, we performed a retrospective study, which collected data for any patient treated for a posterior acetabular wall fracture. At the time of treatment, patients were either treated using a WAAP or a pelvic reconstruction plate. The intraoperative fluoroscopic images for both groups were compared. The quality of reduction and radiological grading were assessed according to the criteria developed by Matta. The clinical assessment was based on a modified Merle d'Aubigne and Postel scoring. RESULTS: 53 patients met the inclusion criteria and were followed up for an average of 38 months. 25 patients were treated with a WAAP (study group, and 28 patients were treated with a pelvic reconstruction plate (control group. The intraoperative fluoroscopic images of the study group confirmed extra-articular screw placement in all cases. In the control group, intra-articular screw placement was observed intraoperatively in 5 patients (17.86%, and the definitive location of the periarticular hardware could not be determined in 4 patients (14.29% during the operation. The differences between the two groups were statistically significant (p = 0.002. In contrast, the quality of fracture reduction, clinical outcomes, and radiological grading in the study group were not significantly different from those of the control group (p>0.05. The radiographic grade was strongly associated with the clinical outcomes in both the study and control groups (p<0.05. CONCLUSION: Reconstruction of posterior wall fractures of the acetabulum using a WAAP can help avoid screw penetration of the hip joint, provide a stable fixation of the posterior wall, and ensure good clinical outcomes.

  2. Augmented reality and ubiquitous computing : The hidden potentialities of augmented reality

    NARCIS (Netherlands)

    Liberati, Nicola

    2016-01-01

    The aim of this paper was to highlight the augmented reality’s potentialities, depicting its main characteristics and focusing attention on what its goal should be in order to have a new technology completely different from those that already exist. From a technological point of view, augmented

  3. MyPlate: Build a Healthy Eating Style

    Science.gov (United States)

    ... help others in their journey to make healthy eating a part of their lives. What Is MyPlate? Food Guide History MyPlate, MyWins Fruits All About the Fruit Group Nutrients and Health Benefits TIPS: Focus on Whole Fruits Food Gallery Take ...

  4. Capillary Refill using Augmented Reality

    OpenAIRE

    Clausen, Christoffer

    2017-01-01

    Master's thesis in Computer science The opportunities within augmented reality is growing. Augmented reality is a combination of the real and the virtual world in real time, and large companies like Microsoft and Google is now investing heavily in the technology. This thesis presents a solution for simulating a medical test called capillary refill, by using augmented reality. The simulation is performed with an augmented reality headset called HoloLens. The HoloLens will recognise a mark...

  5. A prospective randomized study of operative treatment for noncomminuted humeral shaft fractures: conventional open plating versus minimal invasive plate osteosynthesis.

    Science.gov (United States)

    Kim, Ji Wan; Oh, Chang-Wug; Byun, Young-Soo; Kim, Jung Jae; Park, Ki Chul

    2015-04-01

    To compare the clinical and radiologic results of conventional open plating (COP) and minimally invasive plate osteosynthesis (MIPO) in the treatment of noncomminuted humeral shaft fractures. Randomized prospective study. Five level 1 trauma centers. Sixty-eight consecutive patients were randomized into 2 study groups: those treated by COP (COP group; n = 32) and those treated by MIPO (MIPO group; n = 36). Simple humeral shaft fractures (AO/OTA classification types A and B) were reduced by open reduction or closed reduction and fixed with a narrow 4.5/5.0 locking compression plate, metaphyseal locking compression plate, or proximal humeral internal locking system plate to the anterior lateral aspect of the humerus. Fracture healing time, operative time, radiation exposure time, and intraoperative nerve injury. To assess shoulder and elbow function, we used the University of California, Los Angeles (UCLA) scoring system and the Mayo elbow performance index, including the range of motion and pain. Radiographic measurements included fracture alignment, delayed union, and nonunion. Thirty-one fractures (97%) healed in the COP group within 16 weeks, whereas 36 fractures (100%) were healed in the MIPO group by 15 weeks. No significant difference was observed in the operative time or complication rates. In both groups, all fractures achieved union without malunion and with excellent functional outcomes by definition of the Mayo elbow performance index and UCLA scoring system. This study confirmed a high overall rate of union and excellent functional outcomes in both MIPO and COP groups. MIPO is equivalent to COP as a safe and effective method for simple types of humeral shaft fractures when surgery is indicated, and the surgeon is experienced in the technique. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

  6. A novel combined method of osteosynthesis in treatment of tibial fractures: a comparative study on sheep with application of rod-through-plate fixator and bone plating.

    Science.gov (United States)

    Tralman, G; Andrianov, V; Arend, A; Männik, P; Kibur, R T; Nõupuu, K; Uksov, D; Aunapuu, M

    2013-04-01

    The study compares the efficiency of a new bone fixator combining periostal and intramedullary osteosynthesis to bone plating in treatment of tibial fractures in sheep. Experimental osteotomies were performed in the middle third of the left tibia. Animals were divided into two groups: in one group (four animals) combined osteosynthesis (rod-through-plate fixator, RTP fixator) was applied, and in the other group (three animals) bone plating was used. The experiments lasted for 10 weeks during which fracture union was followed by radiography, and the healing process was studied by blood serum markers reflecting bone turnover and by histological and immunohistochemical investigations. In the RTP fixator group, animals started to load body weight on the operated limbs the next day after the surgery, while in the bone plating group, this happened only on the seventh day. In the RTP fixator group, consolidation of fractures was also faster, as demonstrated by radiographical, histological, and immunohistochemical investigations and in part by blood serum markers for bone formation. It can be concluded that application of RTP fixation is more efficient than plate fixation in the treatment of experimental osteotomies of long bones in sheep. © 2012 Blackwell Verlag GmbH.

  7. Augmented Mirror: Interactive Augmented Reality System Based on Kinect

    OpenAIRE

    Vera , Lucía; Gimeno , Jesús; Coma , Inmaculada; Fernández , Marcos

    2011-01-01

    Part 1: Long and Short Papers; International audience; In this paper we present a virtual character controlled by an actor in real time, who talks with an audience through an augmented mirror. The application, which integrates video images, the avatar and other virtual objects within an Augmented Reality system, has been implemented using a mixture of technologies: two kinect systems for motion capture, depth map and real images, a gyroscope to detect head movements, and control algorithms to...

  8. Augmented reality in neurosurgery.

    Science.gov (United States)

    Tagaytayan, Raniel; Kelemen, Arpad; Sik-Lanyi, Cecilia

    2018-04-01

    Neurosurgery is a medical specialty that relies heavily on imaging. The use of computed tomography and magnetic resonance images during preoperative planning and intraoperative surgical navigation is vital to the success of the surgery and positive patient outcome. Augmented reality application in neurosurgery has the potential to revolutionize and change the way neurosurgeons plan and perform surgical procedures in the future. Augmented reality technology is currently commercially available for neurosurgery for simulation and training. However, the use of augmented reality in the clinical setting is still in its infancy. Researchers are now testing augmented reality system prototypes to determine and address the barriers and limitations of the technology before it can be widely accepted and used in the clinical setting.

  9. AR DOC: Augmented reality documentaries

    DEFF Research Database (Denmark)

    Vistisen, Peter

    2014-01-01

    Augmented Reality Documentaries (AR DOC) er et ’lille’ Shareplay projekt (ansøgte midler augmented reality cross media løsninger, til at skabe engagerende publikumsformidling...... indenfor oplevelsesindustrien. Projektet har genereret ny viden omkring, hvordan fysisk og digital formidling kan understøttes via Augmented Reality som formidlingsformat....

  10. Augmented reality games for learning : A literature review

    NARCIS (Netherlands)

    Li, J.; van der Spek, E.D.; Feijs, L.M.G.; Wang, F.; Hu, J.; Streitz, N.; Markopoulos, P.

    2017-01-01

    This study presents a literature review of previous studies of Augmented Reality (AR) games for learning. We classified learner groups, learning subjects, and learning environments mentioned in the literature. From this we conclude that AR games for learning generally have positive effects. We found

  11. PMMA-hydroxyapatite composite material retards fatigue failure of augmented bone compared to augmentation with plain PMMA: in vivo study using a sheep model.

    Science.gov (United States)

    Arabmotlagh, Mohammad; Bachmaier, Samuel; Geiger, Florian; Rauschmann, Michael

    2014-11-01

    Polymethylmethacrylate (PMMA) is the most commonly used void filler for augmentation of osteoporotic vertebral fracture, but the differing mechanical features of PMMA and osteoporotic bone result in overload and failure of adjacent bone. The aim of this study was to compare fatigue failure of bone after augmentation with PMMA-nanocrystalline hydroxyapatite (HA) composite material or with plain PMMA in a sheep model. After characterization of the mechanical properties of a composite material consisting of PMMA and defined amounts (10, 20, and 30% volume fraction) of HA, the composite material with 30% volume fraction HA was implanted in one distal femur of sheep; plain PMMA was implanted in the other femur. Native non-augmented bone served as control. Three and 6 months after implantation, the augmented bone samples were exposed to cyclic loading and the evolution of damage was investigated. The fatigue life was highest for the ovine native bone and lowest for bone-PMMA specimens. Bone-composite specimens showed significantly higher fatigue life than the respective bone-PMMA specimens in both 3- and 6-month follow-up groups. These results suggest that modification of mechanical properties of PMMA by addition of HA to approximate those of cancellous bone retards fatigue failure of the surrounding bone compared to augmented bone with plain PMMA. © 2014 Wiley Periodicals, Inc.

  12. Resorbable versus titanium plates for orthognathic surgery.

    Science.gov (United States)

    Agnihotry, Anirudha; Fedorowicz, Zbys; Nasser, Mona; Gill, Karanjot S

    2017-10-04

    the other titanium with resorbable screws. Both studies were at high risk of bias and provided very limited data for the primary outcomes of this review. All participants in one trial suffered mild to moderate postoperative discomfort with no statistically significant difference between the two plating groups at different follow-up times. Mean scores of patient satisfaction were 7.43 to 8.63 (range 0 to 10) with no statistically significant difference between the two groups throughout follow-up. Adverse effects reported in one study were two plate exposures in each group occurring between the third and ninth months. Plate exposures occurred mainly in the posterior maxillary region, except for one titanium plate exposure in the mandibular premolar region. Known causes of infection were associated with loosened screws and wound dehiscence with no statistically significant difference in the infection rate between titanium (3/196), and resorbable (3/165) plates. We do not have sufficient evidence to determine if titanium plates or resorbable plates are superior for fixation of bones after orthognathic surgery. This review provides insufficient evidence to show any difference in postoperative pain and discomfort, level of patient satisfaction, plate exposure or infection for plate and screw fixation using either titanium or resorbable materials.

  13. Crime Scenes as Augmented Reality

    DEFF Research Database (Denmark)

    Sandvik, Kjetil

    2010-01-01

    Using the concept of augmented reality, this article will investigate how places in various ways have become augmented by means of different mediatization strategies. Augmentation of reality implies an enhancement of the places' emotional character: a certain mood, atmosphere or narrative surplus......, physical damage: they are all readable and interpretable signs. As augmented reality the crime scene carries a narrative which at first is hidden and must be revealed. Due to the process of investigation and the detective's ability to reason and deduce, the crime scene as place is reconstructed as virtual...

  14. The effect of patient age on bone formation using a fully synthetic nanocrystalline bone augmentation material in maxillary sinus grafting.

    Science.gov (United States)

    Wolf, Michael; Wurm, Alexander; Heinemann, Friedhelm; Gerber, Thomas; Reichert, Christoph; Jäger, Andreas; Götz, Werner

    2014-01-01

    Maxillary sinus floor augmentation is a treatment that has been proposed for patients in whom the alveolar bone height is insufficient. This procedure is commonly used in patients aged 40 to 70 years and older. However, little information exists whether the factor of age might influence the outcome of augmentation procedures. The aim of this study was to investigate whether the patient's age has an effect on bone formation and incorporation in maxillary sinus floor augmentation procedures. A fully synthetic nanocrystalline bone augmentation material (NanoBone, Artoss) was used for sinus floor augmentation in patients with a subantral vertical bone height of at least 3 mm and maximum of 7 mm. After 7 months healing time, biopsy specimens were taken and were divided into two groups according to the patient's age. Exclusion criteria were poor general health (eg, severe renal/and or liver disease), history of a radiotherapy in the head region, chemotherapy at the time of surgical procedure, noncompensated diabetes mellitus, symptoms of a maxillary sinus disease, active periodontal or systemic diseases, smoking, and poor oral hygiene. Histologic analyses with hematoxylin-eosin stain were performed. Multinucleated osteoclast-like cells were identified by histochemical staining (tartrate-resistant acid phosphatase [TRAP]). Quantitative and age-dependent assessment of bone formation, residual bone grafting material, and soft tissue formation following sinus augmentation was performed using histomorphometric analysis and the Bonferroni adjustment of the Student t test. Twenty biopsy specimens from 17 patients were taken and divided into two groups according to age (group 1: 41 to 52 years; group 2: 66 to 71 years) containing 10 specimens each, which were analyzed in triplicate resulting in a total of 30 specimens per group. A regeneration process with varying amounts of newly formed bone surrounded by marrow-like tissue was present in all augmented regions. No signs of

  15. Hydrodynamics of a flexible plate between pitching rigid plates

    Science.gov (United States)

    Kim, Junyoung; Kim, Daegyoum

    2017-11-01

    The dynamics of a flexible plate have been studied as a model problem in swimming and flying of animals and fluid-structure interaction of plants and flags. Motivated by fish schooling and an array of sea grasses, we investigate the dynamics of a flexible plate closely placed between two pitching rigid plates. In most studies on passive deformation of the flexible plate, the plate is immersed in a uniform flow or a wavy flow. However, in this study, the flexible plate experiences periodic deformation by the oscillatory flow generated by the prescribed pitching motion of the rigid plates. In our model, the pitching axes of the rigid plates and the clamping position of the flexible plate are aligned on the same line. The flexible plate shows various responses depending on length and pitching frequency of rigid plates, thickness of a flexible plate, and free-stream velocity. To find the effect of each variable on the response of the flexible plate, amplitude of a trailing edge and modal contribution of a flapping motion are compared, and flow structure around the flexible plate is examined.

  16. Evaluation of Bone Atrophy After Treatment of Forearm Fracture Using Nonlinear Finite Element Analysis: A Comparative Study of Locking Plates and Conventional Plates.

    Science.gov (United States)

    Matsuura, Yusuke; Rokkaku, Tomoyuki; Suzuki, Takane; Thoreson, Andrew Ryan; An, Kai-Nan; Kuniyoshi, Kazuki

    2017-08-01

    Forearm diaphysis fractures are usually managed by open reduction internal fixation. Recently, locking plates have been used for treatment. In the long-term period after surgery, some patients present with bone atrophy adjacent to the plate. However, a comparison of locking and conventional plates as a cause of atrophy has not been reported. The aim of this study was to investigate long-term bone atrophy associated with use of locking and conventional plates for forearm fracture treatment. In this study we included 15 patients with forearm fracture managed by either locking or conventional plates and with more than 5 years of follow-up. Computed tomographic imaging of both forearms was performed to assess bone thickness and local bone mineral density and to predict bone strength without plate reinforcement based on finite element analysis. Mean patient age at surgery was 48.0 years. Eight patients underwent reduction with fixed locking plates and were followed up for a mean of 79.5 months; the remaining 7 patients were treated with conventional plates and were followed up for a mean of 105.0 months. Compared with the conventional plate group, the locking plate group had the same fractured limb-contralateral limb ratio of cortex bone thickness, but had significantly lower ratios of mineral density adjacent to the plate and adjusted bone strength. This study demonstrated bone atrophy after locking plate fixation for forearm fractures. Treatment plans for forearm fracture should take into consideration the impact of bone atrophy long after plate fixation. Therapeutic IV. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  17. [Development of polyaxial locking plate screw system of sacroiliac joint].

    Science.gov (United States)

    Fan, Weijie; Xie, Xuesong; Zhou, Shuping; Zhang, Yonghu

    2014-09-01

    To develop an instrument for sacroiliac joint fixation with less injury and less complications. Firstly, 18 adult pelvic specimens (8 males and 10 females) were used to measure the anatomical data related to the locking plates and locking screws on the sacrum and ilium, and the polyaxial locking plate screw system of the sacroiliac joint was designed according to the anatomic data. This system was made of medical titanium alloy. Then 4 adult male plevic specimens were harvested and the experiment was divided into 3 groups: group A (normal pelvic), group B (the dislocated sacroiliac joint fixed with sacroiliac screws), and group C (the dislocated sacroiliac joint fixed with polyaxial locking plate screw system). The vertical displacement of sacroiliac joint under the condition of 0-700 N vertical load and the horizontal displacement on angle under the condition of 0-12 N·m torsional load were compared among the 3 groups by using the biological material test system. Finally, the simulated application test was performed on 1 adult male cadaveric specimen to observe soft tissue injury and the position of the locking plate and screw by X-ray films. According to the anatomic data of the sacrum and ilium, the polyaxial locking plate screw system of the sacroiliac joint was designed. The biomechanical results showed that the vertical displacement of the sacroiliac joint under the condition of 0-700 N vertical load in group A was significantly bigger than that in group B and group C (P 0.05). The horizontal displacement on angle under the condition of 0-12 N·m torsional load in group A was significantly less than that in group B and group C (P 0.05). The test of simulating application showed that the specimen suffered less soft tissue injury, and this instrument could be implanted precisely and safely. The polyaxial locking plate screw system of the sacroiliac joint has the advantages of smaller volume and less injury; polyaxial fixation enables flexible adjustment screw

  18. Influence of cement compressive strength and porosity on augmentation performance in a model of orthopedic screw pull-out.

    Science.gov (United States)

    Pujari-Palmer, Michael; Robo, Celine; Persson, Cecilia; Procter, Philip; Engqvist, Håkan

    2018-01-01

    Disease and injuries that affect the skeletal system may require surgical intervention and internal fixation, i.e. orthopedic plate and screw insertion, to stabilize the injury and facilitate tissue repair. If the surrounding bone quality is poor the screws may migrate, or the bone may fail, resulting in fixation failure. While numerous studies have shown that cement augmentation of the interface between bone and implant can increase screw pull-out force, the physical properties of cement that influence pull-out force have not been investigated. The present study sought to determine how the physical properties of high strength calcium phosphate cements (hsCPCs, specifically dicalcium phosphate) affected the corresponding orthopedic screw pull-out force in urethane foam models of "healthy" and "osteoporotic" synthetic bone (Sawbones). In the simplest model, where only the bond strength between screw thread and cement (without Sawbone) was tested, the correlation between pull-out force and cement compressive strength (R 2 = 0.79) was weaker than correlation with total cement porosity (R 2 = 0.89). In open pore Sawbone that mimics "healthy" cancellous bone density the stronger cements produced higher pull-out force (50-60% increase). High strength, low porosity cements also produced higher pull-out forces (50-190% increase) in "healthy" Sawbones with cortical fixation if the failure strength of the cortical material was similar to, or greater than (a metal shell), actual cortical bone. This result is of particular clinical relevance where fixation with a metal plate implant is indicated, as the nearby metal can simulate a thicker cortical shell, thereby increasing the pull-out force of screws augmented with stronger cements. The improvement in pull-out force was apparent even at low augmentation volumes of 0.5mL (50% increase), which suggest that in clinical situations where augmentation volume is limited the stronger, lower porosity calcium phosphate cement (CPC) may

  19. CAD-CAM plates versus conventional fixation plates for primary mandibular reconstruction: A biomechanical in vitro analysis.

    Science.gov (United States)

    Rendenbach, Carsten; Sellenschloh, Kay; Gerbig, Lucca; Morlock, Michael M; Beck-Broichsitter, Benedicta; Smeets, Ralf; Heiland, Max; Huber, Gerd; Hanken, Henning

    2017-11-01

    CAD/CAM reconstruction plates have become a viable option for mandible reconstruction. The aim of this study was to determine whether CAD/CAM plates provide higher fatigue strength compared with conventional fixation systems. 1.0 mm miniplates, 2.0 mm conventional locking plates (DePuy Synthes, Umkirch, Germany), and 2.0 mm CAD/CAM plates (Materialise, Leuven, Belgium/DePuy Synthes) were used to reconstruct a polyurethane mandible model (Synbone, Malans, CH) with cortical and cancellous bone equivalents. Mastication was simulated via cyclic dynamic testing using a universal testing machine (MTS, Bionix, Eden Prairie, MN, USA) until material failure reached a rate of 1 Hz with increasing loads on the left side. No significant difference was found between the groups until a load of 300 N. At higher loads, vertical displacement differed increasingly, with a poorer performance of miniplates (p = 0.04). Plate breakage occurred in miniplates and conventional locking plates. Screw breakage was recorded as the primary failure mechanism in CAD/CAM plates. Stiffness was significantly higher with the CAD/CAM plates (p = 0.04). CAD/CAM plates and reconstruction plates provide higher fatigue strength than miniplates, and stiffness is highest in CAD/CAM systems. All tested fixation methods seem sufficiently stable for mandible reconstruction. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  20. Augmented reality: a review.

    Science.gov (United States)

    Berryman, Donna R

    2012-01-01

    Augmented reality is a technology that overlays digital information on objects or places in the real world for the purpose of enhancing the user experience. It is not virtual reality, that is, the technology that creates a totally digital or computer created environment. Augmented reality, with its ability to combine reality and digital information, is being studied and implemented in medicine, marketing, museums, fashion, and numerous other areas. This article presents an overview of augmented reality, discussing what it is, how it works, its current implementations, and its potential impact on libraries.

  1. Plate fixation in periprosthetic femur fractures Vancouver type B1-Trochanteric hook plate or subtrochanterical bicortical locking?

    Science.gov (United States)

    Lenz, Mark; Stoffel, Karl; Kielstein, Heike; Mayo, Keith; Hofmann, Gunther O; Gueorguiev, Boyko

    2016-12-01

    Proximal plate fixation in periprosthetic femur fractures can be improved by plate anchorage in the greater trochanter (lateral tension band principle) or bicortical locking screw placement beside the prosthesis stem in an embracement configuration. Both concepts were compared in a biomechanical test using a femoral hook plate (hook) or a locking attachment plate (LAP). After bone mineral density (BMD) measurement in the greater trochanter, six pairs of fresh frozen human femora were assigned to two groups and instrumented with cemented hip endoprostheses. A transverse osteotomy was set distal to the tip of the prosthesis, simulating a Vancouver B1 fracture. Each pair was instrumented using a plate tensioner with either hook or LAP construct. Cyclic testing (2Hz) with physiologic profile and monotonically increasing load was performed until catastrophic failure. Plate stiffness was compared in a four-point-bending-test. Paired student's-t-test was used for statistical evaluation (pTrochanteric fixation is highly BMD dependent and may be restricted to major greater trochanteric involvement requiring stabilization. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Cranial implant design using augmented reality immersive system.

    Science.gov (United States)

    Ai, Zhuming; Evenhouse, Ray; Leigh, Jason; Charbel, Fady; Rasmussen, Mary

    2007-01-01

    Software tools that utilize haptics for sculpting precise fitting cranial implants are utilized in an augmented reality immersive system to create a virtual working environment for the modelers. The virtual environment is designed to mimic the traditional working environment as closely as possible, providing more functionality for the users. The implant design process uses patient CT data of a defective area. This volumetric data is displayed in an implant modeling tele-immersive augmented reality system where the modeler can build a patient specific implant that precisely fits the defect. To mimic the traditional sculpting workspace, the implant modeling augmented reality system includes stereo vision, viewer centered perspective, sense of touch, and collaboration. To achieve optimized performance, this system includes a dual-processor PC, fast volume rendering with three-dimensional texture mapping, the fast haptic rendering algorithm, and a multi-threading architecture. The system replaces the expensive and time consuming traditional sculpting steps such as physical sculpting, mold making, and defect stereolithography. This augmented reality system is part of a comprehensive tele-immersive system that includes a conference-room-sized system for tele-immersive small group consultation and an inexpensive, easily deployable networked desktop virtual reality system for surgical consultation, evaluation and collaboration. This system has been used to design patient-specific cranial implants with precise fit.

  3. Use of Augmented Reality in Education

    OpenAIRE

    Jeřábek, Tomáš

    2014-01-01

    This thesis deals with phenomena of augmented reality in context of didactics. The thesis aims to define augmented reality in conceptual and content area and focuses on augmented reality in the structure of educational tools and identification of its functions and use from the didactical standpoint. The thesis characterizes augmented reality as a specific technological-perceptual concept and establishes a system of perceptual, technological and resulting aspects that reflect important paramet...

  4. Advanced Theory of Mind in Children Using Augmentative and Alternative Communication

    Science.gov (United States)

    Sundqvist, Anett; Ronnberg, Jerker

    2010-01-01

    This study focused on the attainment of Theory of Mind (ToM) in children (aged 6 to 13) with complex communication needs who used augmentative and alternative communication (AAC). The AAC group (n = 14) was matched to a younger group, without disabilities, vis-a-vis nonverbal mental age. A second comparison group consisting of children with mild…

  5. Bayesian Alternation During Tactile Augmentation

    Directory of Open Access Journals (Sweden)

    Caspar Mathias Goeke

    2016-10-01

    Full Text Available A large number of studies suggest that the integration of multisensory signals by humans is well described by Bayesian principles. However, there are very few reports about cue combination between a native and an augmented sense. In particular, we asked the question whether adult participants are able to integrate an augmented sensory cue with existing native sensory information. Hence for the purpose of this study we build a tactile augmentation device. Consequently, we compared different hypotheses of how untrained adult participants combine information from a native and an augmented sense. In a two-interval forced choice (2 IFC task, while subjects were blindfolded and seated on a rotating platform, our sensory augmentation device translated information on whole body yaw rotation to tactile stimulation. Three conditions were realized: tactile stimulation only (augmented condition, rotation only (native condition, and both augmented and native information (bimodal condition. Participants had to choose one out of two consecutive rotations with higher angular rotation. For the analysis, we fitted the participants’ responses with a probit model and calculated the just notable difference (JND. Then we compared several models for predicting bimodal from unimodal responses. An objective Bayesian alternation model yielded a better prediction (χred2 = 1.67 than the Bayesian integration model (χred2= 4.34. Slightly higher accuracy showed a non-Bayesian winner takes all model (χred2= 1.64, which either used only native or only augmented values per subject for prediction. However the performance of the Bayesian alternation model could be substantially improved (χred2= 1.09 utilizing subjective weights obtained by a questionnaire. As a result, the subjective Bayesian alternation model predicted bimodal performance most accurately among all tested models. These results suggest that information from augmented and existing sensory modalities in

  6. Augmented Reality

    DEFF Research Database (Denmark)

    Kjærgaard, Hanne Wacher; Kjeldsen, Lars Peter Bech; Rahn, Annette

    2015-01-01

    This chapter describes the use of iPad-facilitated application of augmented reality in the teaching of highly complex anatomical and physiological subjects in the training of nurses at undergraduate level. The general aim of the project is to investigate the potentials of this application in terms...... of making the complex content and context of these subjects more approachable to the students through the visualization made possible through the use of this technology. A case study is described in this chapter. Issues and factors required for the sustainable use of the mobile-facilitated application...... of augmented reality are discussed....

  7. Affordances in Mobile Augmented Reality Applications

    OpenAIRE

    Gjøsæter, Tor

    2014-01-01

    This paper explores the affordances of augmented reality content in a mobile augmented reality application. A user study was conducted by performing a multi-camera video recording of seven think aloud sessions. The think aloud sessions consisted of individual users performing tasks, exploring and experiencing a mobile augmented reality (MAR) application we developed for the iOS platform named ARad. We discuss the instrumental affordances we observed when users interacted with augmented realit...

  8. Dynamic augmentation restores anterior tibial translation in ACL suture repair: a biomechanical comparison of non-, static and dynamic augmentation techniques.

    Science.gov (United States)

    Hoogeslag, Roy A G; Brouwer, Reinoud W; Huis In 't Veld, Rianne; Stephen, Joanna M; Amis, Andrew A

    2018-02-03

    There is a lack of objective evidence investigating how previous non-augmented ACL suture repair techniques and contemporary augmentation techniques in ACL suture repair restrain anterior tibial translation (ATT) across the arc of flexion, and after cyclic loading of the knee. The purpose of this work was to test the null hypotheses that there would be no statistically significant difference in ATT after non-, static- and dynamic-augmented ACL suture repair, and they will not restore ATT to normal values across the arc of flexion of the knee after cyclic loading. Eleven human cadaveric knees were mounted in a test rig, and knee kinematics from 0° to 90° of flexion were recorded by use of an optical tracking system. Measurements were recorded without load and with 89-N tibial anterior force. The knees were tested in the following states: ACL-intact, ACL-deficient, non-augmented suture repair, static tape augmentation and dynamic augmentation after 10 and 300 loading cycles. Only static tape augmentation and dynamic augmentation restored ATT to values similar to the ACL-intact state directly postoperation, and maintained this after cyclic loading. However, contrary to dynamic augmentation, the ATT after static tape augmentation failed to remain statistically less than for the ACL-deficient state after cyclic loading. Moreover, after cyclic loading, ATT was significantly less with dynamic augmentation when compared to static tape augmentation. In contrast to non-augmented ACL suture repair and static tape augmentation, only dynamic augmentation resulted in restoration of ATT values similar to the ACL-intact knee and decreased ATT values when compared to the ACL-deficient knee immediately post-operation and also after cyclic loading, across the arc of flexion, thus allowing the null hypotheses to be rejected. This may assist healing of the ruptured ACL. Therefore, this study would support further clinical evaluation of dynamic augmentation of ACL repair.

  9. Augment-type two stage accelerator

    International Nuclear Information System (INIS)

    Ogino, Mutsuo; Azuma, Kingo.

    1995-01-01

    When a flying body accelerated by a gas gun at a first stage enters into an augment rail passing through an introduction tube, an ignition capacitor for initial plasmas is turned ON to apply a voltage between the augment rails. Subsequently, the accelerating gas present behind the flying body is formed into plasmas by a laser, to flow electric current from one of the inner augment rails → plasma armature → the other of the inner augment rails, and additionally accelerate the flying body by Lorentz force formed in this case. Since the plasmas are maintained in a state of higher density than the plasmas obtained by using all of the augment rails, the ignition capacitor for initial plasmas in switched to a power source. As a result, it is possible to flow the maximum current before the plasmas expand, and a large accelerating force and a high magnetic flux density are attained, to improve acceleration performance of the flying body. (N.H.)

  10. Plate fixation for proximal chevron osteotomy has greater risk for hallux valgus recurrence than Kirschner wire fixation.

    Science.gov (United States)

    Park, Chul-Hyun; Ahn, Ji-Yong; Kim, Yu-Mi; Lee, Woo-Chun

    2013-06-01

    The purpose of this study was to compare the results of hallux valgus surgery between feet fixed with Kirschner wires and those fixed with a plate and screws. Between December 2008 and November 2009, 53 patients (62 feet) were treated with proximal chevron osteotomy and distal soft tissue procedure for symptomatic moderate to severe hallux valgus deformity. Thirty-four patients (41 feet) were stabilised with Kirschner wires (K-wire group) and 19 patients (21 feet) were stabilised with a locking plate (plate group). Clinical results were assessed using American Orthopaedic Foot and Ankle Society (AOFAS) score. Radiographic parameters were compared between these groups. Recurrence rate at the last follow-up was compared between the K-wire and plate groups. Mean AOFAS score was lower in the plate group, however, the difference between the groups was not statistically significant in AOFAS score at the last follow-up. Hallux valgus angle and intermetatarsal angle were significantly larger in the plate group at the last follow-up. Mean 1-2 metatarsal (MT) distance on immediately postoperative radiographs was significant larger in the plate group. Four (9.8 %) of the 41 feet in the K-wire group and 7 (33.3 %) of the 21 feet in the plate group showed hallux valgus recurrence at the last follow-up. The plate group had a significantly higher risk of recurrence than the K-wire group. Fixation of proximal chevron osteotomy using a plate and screws has a greater risk of hallux valgus recurrence than fixation using Kirschner wires.

  11. 2-Dimensional changes of the soft tissue profile of augmented and non-augmented human extraction sockets: a randomized pilot study.

    Science.gov (United States)

    Flügge, Tabea; Nelson, Katja; Nack, Claudia; Stricker, Andres; Nahles, Susanne

    2015-04-01

    This study identified the soft tissue changes of the alveolar ridge at different time points within 12 weeks after tooth extraction with and without socket augmentation. In 38 patients with single tooth extractions, 40 sockets were augmented and 39 extraction sockets were not augmented. At 2, 4, 6, 8 and 12 weeks impressions were taken and casts digitized with a laser scanner. The horizontal and vertical changes were compared between augmented and non-augmented sites. A p-value sockets were between 0.4 mm (2 weeks) and 0.8 mm (12 weeks). In non-augmented sockets changes of 0.7 mm (2 weeks) and of 1.0 mm (12 weeks) were demonstrated. The mean values differed significantly between the buccal and oral region (p sockets showed less resorption within 4 weeks after extraction compared to non-augmented sockets. Non-augmented sockets showed a continuous dimensional loss with a great variation over 12 weeks whereas augmented sockets had the highest degree of resorption between 4 and 6 weeks. At 12 weeks a comparable resorption in augmented and non-augmented sockets was observed. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Augmented assessment as a means to augmented reality.

    Science.gov (United States)

    Bergeron, Bryan

    2006-01-01

    Rigorous scientific assessment of educational technologies typically lags behind the availability of the technologies by years because of the lack of validated instruments and benchmarks. Even when the appropriate assessment instruments are available, they may not be applied because of time and monetary constraints. Work in augmented reality, instrumented mannequins, serious gaming, and similar promising educational technologies that haven't undergone timely, rigorous evaluation, highlights the need for assessment methodologies that address the limitations of traditional approaches. The most promising augmented assessment solutions incorporate elements of rapid prototyping used in the software industry, simulation-based assessment techniques modeled after methods used in bioinformatics, and object-oriented analysis methods borrowed from object oriented programming.

  13. A distal femoral supra-condylar plate: biomechanical comparison with condylar plate and first clinical application for treatment of supracondylar fracture.

    Science.gov (United States)

    Liang, Bowei; Ding, Zhenqi; Shen, Junguo; Zhai, Wenliang; Kang, Liangqi; Zhou, Liang; Sha, Mo; Liang, Dongzhu

    2012-08-01

    An anatomical supra-condylar plate is designed and analysed by biomechanical testing. The biomechanical properties of the supra-condylar and condylar plate were compared in six matched pairs of cadaveric femurs. A transverse osteotomy gap was created to simulate an OTA/AO type A3 supracondylar fracture. The left and right specimens were fitted with supra-condylar and condylar plate, respectively. Nondestructive axial compression, three-point bending and torsion tests were performed, and the peak load of the bone-implant construction was measured. The fracture site suitable for supra-condylar plate application and its correlation with femoral length were calculated. The gender influence on it was also discussed. The difference of stiffness between the supra-condylar and condyle groups were not significant (P > 0.05) at 363.4 and 362.5 N/mm for compression, 229.5 and 237.6 N/mm in the sagittal plane and 195.5 and 188.4 N/mm in the coronal plane for three-point bending, and 7.5 and 7.9 Nm/deg for axial torsion, respectively. The peak load was 4438 ± 136.15 N and 5215 ± 174.33 N, respectively, for the two groups. The average extent of the fracture site suitable for the application of the supra-condylar plate was 70.86 ± 4.61 mm. The femoral length and gender showed no influence on it. Despite the limited bone contact area provided by the supra-condylar plate, its construct stiffness is comparable to the condylar plate. The supra-condylar plate can be used to treat carefully-selected extra-articular supracondylar fractures.

  14. Augmented Reality Using JavaScript

    OpenAIRE

    Hailemichael, Aida

    2013-01-01

    The project goal was to provide a mobile application, for a venue called Kulturhuset Karelia which is located in Tammisaari Finland. In this paper, the concept of Augmented Reality technology is briefly discussed along with the mobile application for the venue. The utilisation of JavaScript for creating Augmented reality content for mobile Augmented reality browser is also demonstrated. The application was created by using Architecht API which is Jacvascript library based on the Wikitude...

  15. Augmented Reality for Multi-disciplinary Collaboration

    OpenAIRE

    Wang, Xiangyu; Rui,

    2010-01-01

    This chapter presents a framework for multi-disciplinary collaboration. Tangible Augmented Reality has been raised as one of suitable systems for design collaboration. Furthermore, it emphasizes the advantages of Tangible Augmented Reality to illustrate the needs for integrating the Tangible User Interfaces and Augmented Reality Systems.

  16. Pindolol augmentation in treatment-resistant obsessive compulsive disorder: a double-blind placebo controlled trial.

    Science.gov (United States)

    Dannon, P N; Sasson, Y; Hirschmann, S; Iancu, I; Grunhaus, L J; Zohar, J

    2000-05-01

    To evaluate the efficacy of pindolol augmentation in treatment-resistant obsessive compulsive disorder (OCD) patients who were unsuccessfully treated with serotonin reuptake inhibitors. Fourteen treatment-resistant OCD patients were treated with paroxetine for 17.4+/-2.1 weeks up to 60 mg/d after they failed at least two other serotonin reuptake inhibitor trials. The patients, who did not respond to open-label paroxetine treatment, were assigned to a double-blind, placebo-controlled pindolol (2.5 mgx3/d) augmentation. All the subjects were evaluated biweekly for a six-week period with the Yale-Brown Obsessive Compulsive Scale (Y-BOCS), Hamilton Anxiety Scale (HAM-Anx), and Montgomery Asberg Depression Rating Scale (MADRS). Data was analyzed by paired t-test, and ANOVA with repeated measures. Pindolol augmentation to paroxetine (n=8) as compared to placebo augmentation (n=6), was associated with a significant (P<0.01) improvement in Y-BOCS as measured by paired t-test after the fourth week of the treatment and by ANOVA with repeated measures (df: 4.9, f: 3,3, P<0.006). Although no significant differences were found between placebo and pindolol groups on HAM-Anx and MADRS, a trend for improvement in the pindolol group was noted. The results of our study demonstrated that pindolol may augment the therapeutic effect of paroxetine in treatment-resistant OCD patients.

  17. THE NEW STRUCTURE OF A PLATE-PILE FOUNDATION

    Directory of Open Access Journals (Sweden)

    SAMORODOV О. V.

    2016-01-01

    Full Text Available Raising of problem. In the construction of high-rise buildings with significant loads on foundations and bedding at the base of not rocky soils tend to use the most common pile foundation to reduce the deformation and correspond to regulations [1] on the maximum permissible deformation. Monitoring of the stress-strain state (SSS pile foundations constructed buildings shows the existing reserves of bearing capacity on the one hand - soil bases of the second group of limit states, on the other - the foundation of the first group of limit states by regulating the SSS foundation during construction and exploitation. Therefore, are increasingly using more progressive structure of foundations consisting of piles and of plate, as well as methods for their construction [2 - 10], however, in their design there are a number of disadvantages associated with the ambiguity of the application of methods for the calculation of such structures, which allows to do only partial conclusions and recommendations. Purpose. Is proposing the new structure of a plate-pile foundation, which overcomes the drawbacks of the existing design solutions and methods of consruction their, as well as is proposing an engineering method of a determination of basic parameters. Conclusion. Is proposes the new structure of a plate-pile foundation and the method of a determination of basic parameters his in the design of a soil base to the maximum permissible deformation Su buildings. Efficiency of application this type plate-pile foundation obtained by rational distribution resistance between a plate and piles, when under load from the building to the first work fully incorporated plate that allows maximum deformed for plate, and then the piles - due to of the hinge connection with the plate. Thus, depending on the maximum permissible deformation for buildings resistance of plate part of a full load of more than 50%, that significantly reduces the consumption of concrete.

  18. [Curative efficacies of mini-invasive percutaneous osteosynthesis versus supercutaneous plating for distal tibial fractures].

    Science.gov (United States)

    He, Xianfeng; Zhu, Limei; Zhang, Jingwei; Li, Ming; Yu, Yihui

    2014-12-30

    To compare the clinical efficacies of mini-invasive percutaneous osteosynthesis (MIPO) versus supercutaneous plating with closed reduction in the treatment of distal tibial fractures. A total of 48 patients with close distal tibial fractures were treated between January 2010 and January 2012. The MIPO group included 16 males and 8 females with an average age of 36 years. And the types were A (n = 15), B (n = 6) and C (n = 3) according to the classification scheme of Association for the Study of Internal Fixation (AO/ASIF). The supercutaneous plating group also included 16 males and 8 females with an average age of 37 years. And the types were A (n = 15), B (n = 6) and C (n = 3). And the operative duration, hospital stay, union time, postoperative complications and function of ankle were compared between two groups. The mean follow-up period was 18.5 (12-26) months. There was no instance of nonunion, hardware breakdown or deep infection. Patients in supercutaneous plating group had significantly shorter mean operative duration, hospital stay and union time. Three patients and 1 patient in MIPO group presented with superficial infection and delayed union respectively while there was no occurrence in supercutaneous plating group. And the differences were not statistically significant. Fifteen patients (62.5%) complained of implant impingement or discomfort. And stripping occurred at an incidence of 15.6% during the removal time of locking screws in MIPO group. While in supercutaneous plating group, there as no complaint of skin irritation and removal of supercutaneous plate was easily performed without anesthesia. The mean AOFAS score was 90.7 ± 3.8 in supercutaneous plating group versus 88.9 ± 4.1 in MIPO group (P = 0.070). Distal tibia fractures may be treated successfully with MIPO or supercutaneous plating. However, supercutaneous plating offers multiple advantages in terms of mean operative duration, hospital stay, union time, skin irritation and implant

  19. Placebo-Controlled Study of Pimozide Augmentation of Fluoxetine in Body Dysmorphic Disorder

    Science.gov (United States)

    Phillips, Katharine A.

    2006-01-01

    Objective Although body dysmorphic disorder often responds to serotonin reuptake inhibitors (SRIs), most patients do not respond or respond only partially. However, placebo-controlled studies of augmentation of SRIs have not been done. Furthermore, although 40%–50% of patients are delusional, studies of antipsychotic medications have not been done. Method Twenty-eight patients with body dysmorphic disorder or its delusional variant participated in an 8-week, placebo-controlled, double-blind, parallel-group study of pimozide augmentation of fluoxetine. Results Pimozide was not more effective than placebo: two (18.2%) of 11 subjects responded to pimozide and three (17.6%) of 17 subjects responded to placebo. There was no significant effect of baseline delusionality on endpoint severity of body dysmorphic disorder. Delusionality did not decrease significantly more with pimozide than placebo. Conclusions Pimozide augmentation of fluoxetine treatment for body dysmorphic disorder was not more effective than placebo, even in more delusional patients. Further studies of augmentation for SRIs are needed. PMID:15677604

  20. Performance of a self-augmented railgun

    International Nuclear Information System (INIS)

    Burton, R.L.; Witherspoon, F.D.; Goldstein, S.A.

    1991-01-01

    The accelerating force of a railgun 1/2L'I 2 a can be increased by augmenting the self-induced magnetic field created by the armature current. Augmentation fields can be produced by external current coils or, as is done here, by shorting the railgun muzzle, and using the gun rails as the augmentation coil. Experimental results are presented for a 3.6-m railgun operated in this self-augmented mode, and effective inductance gradients are achieved which are as much as 9.3 times that of the unaugmented gun. A circuit model is presented which explains features of the measured shunt current and voltage. It is concluded that self-augmentation is an effective way to reduce ohmic heating in the armature of a railgun

  1. INFORMATION VIA AUGMENTED

    OpenAIRE

    Tetteh, Sampson

    2015-01-01

    The vast majority of mobile technology today has developed over the past dec-ades. The thirst for information and communication has brought about high data transfer speed on modern mobile handset devices. This makes it possible for Augmented Reality to be used on mobile phones. Vaasa University of Applied Science, Technobothnia science resource center and Lumivaara Museum saw the importance of information and decided to embark on a pilot project where Augmented Reality will not be only us...

  2. Comparison of external dacryocystorhinostomy and 5-fluorouracil augmented endonasal laser dacryocystorhinostomy. A Retrospective review

    Directory of Open Access Journals (Sweden)

    Watts Patrick

    2001-01-01

    Full Text Available Purpose: To compare the success rates of external dacryocystorhinostomy (EXT-DCR with 5-fluorouracil (5-FU augmented endonasal laser dacryocystorhinostomy (ENL-DCR and to record the complications associated with 5-FU augmented ENL-DCR Materials and Methods: This was a retrospective non-randomised study. Forty-one patients with primary acquired nasolacrimal duct obstruction underwent an EXT-DCR (19 patients or an ENL-DCR (22 patients over a 3-year period. A Holmium YAG laser (Ho:YAG was used in the latter group of patients. Silicone tubes intubated in all patients were removed at three months. 5-FU was applied intraoperatively at the site of the ostium in the ENL-DCR patients. The median follow-up was 12 months (range 3-24 months for the ENL-DCR group and 22 months (range 6-28 months for the EXT-DCR group. The patency of the lacrimal system and the severity of epiphora were assessed at a final-review. Results: The median age of the EXT-DCR group was 77 years (range 53-87 and that of the ENL-DCR group was 71 years (range 23 to 84. There were 12 female patients in the former group and 19 in the latter. The percentage of success in the EXT-DCR group was 94.7% (95% confidence interval (CI = 75.4-99.1 = , and 63.6% in the ENL-DCR group (95% CI= 43.0-80.3. The confidence interval for the difference of 31.1% was 5.6-52.2. There was a statistically significant difference between the two groups, p=0.024 (Fisher exact test. Conclusions: These data suggest that EXT-DCR provides better results than 5-FU augmented ENL-DCR. However, ENL-DCR is the procedure of choice in certain circumstances such as in elderly, frail or medically unfit patients. Our results of 5-FU augmented ENL-DCR compare favourably with other published series.

  3. Does Augmented Reality Affect High School Students' Learning Outcomes in Chemistry?

    Science.gov (United States)

    Renner, Jonathan Christopher

    Some teens may prefer using a self-directed, constructivist, and technologic approach to learning rather than traditional classroom instruction. If it can be demonstrated, educators may adjust their teaching methodology. The guiding research question for this study focused on how augmented reality affects high school students' learning outcomes in chemistry, as measured by a pretest and posttest methodology when ensuring that the individual outcomes were not the result of group collaboration. This study employed a quantitative, quasi-experimental study design that used a comparison and experimental group. Inferential statistical analysis was employed. The study was conducted at a high school in southwest Colorado. Eighty-nine respondents returned completed and signed consent forms, and 78 participants completed the study. Results demonstrated that augmented reality instruction caused posttest scores to significantly increase, as compared to pretest scores, but it was not as effective as traditional classroom instruction. Scores did improve under both types of instruction; therefore, more research is needed in this area. The present study was the first quantitative experiment controlling for individual learning to validate augmented reality using mobile handheld digital devices that affected individual students' learning outcomes without group collaboration. This topic was important to the field of education as it may help educators understand how students learn and it may also change the way students are taught.

  4. Calcium phosphate barrier for augmentation of bone in noncontained periodontal osseous defects: a novel approach.

    Science.gov (United States)

    Chopra, Aditi; Sivaraman, Karthik; Awataramaney, Tarun K

    2014-11-01

    The aim of this technique is to augment bone in non-contained osseous deformities using a unique self-sustaining calcium phosphate barrier. Bone has the inherent ability to regenerate completely if it is provided with a fracture space or an undisturbed enclosed scaffold. A secluded environment is essential as it provides a secured, sterile and stable wound system that regenerates lost bone by a process of osteopromotion. Reconstructive techniques using bone grafts and barrier membranes utilize this principle for augmentation of deficient bony sites by providing a closed environment that promotes clot stability, graft retention, and facilitates correct cell repopulation. However, in noncontained bone defects like one walled infrabony periodontal defect or sites with horizontal bone loss, regeneration of bone still remains an unrealistic situation since osseous topography at such sites does not favor membrane stability or bone grafts retention. This case report presents a promising technique to augment bone in areas with horizontal loss. Augmentation of bone in the interdental area with horizontal bone loss was accomplished by building a contained defect using a unique self sustaining calcium phosphate cement formulation. The calcium phosphate barrier stimulates the lost cortical plates and promotes graft retention and clot stability. At 6 months, there was a significant bone fill and trabecular formation in the interdental area and reduction in tooth mobility. This promising technique could prove to be a good alternative to the conventional approaches for treating osseous deformities. Calcium phosphate is a promising barrier graft for repair of noncontained periodontal osseous defect. This technique cues both the clinicians and manufacturers to develop moldable tissue engineered constructs for osseous repair.

  5. AUGMENTATION-RELATED BRAIN PLASTICITY

    Directory of Open Access Journals (Sweden)

    Giovanni eDi Pino

    2014-06-01

    Full Text Available Today, the anthropomorphism of the tools and the development of neural interfaces require reconsidering the concept of human-tools interaction in the framework of human augmentation. This review analyzes the plastic process that the brain undergoes when it comes into contact with augmenting artificial sensors and effectors and, on the other hand, the changes that the use of external augmenting devices produces in the brain.Hitherto, few studies investigated the neural correlates of augmentation, but clues on it can be borrowed from logically-related paradigms: sensorimotor training, cognitive enhancement, cross-modal plasticity, sensorimotor functional substitution, use and embodiment of tools.Augmentation modifies function and structure of a number of areas, i.e. primary sensory cortices shape their receptive fields to become sensitive to novel inputs. Motor areas adapt the neuroprosthesis representation firing-rate to refine kinematics. As for normal motor outputs, the learning process recruits motor and premotor cortices and the acquisition of proficiency decreases attentional recruitment, focuses the activity on sensorimotor areas and increases the basal ganglia drive on the cortex. Augmentation deeply relies on the frontoparietal network. In particular, premotor cortex is involved in learning the control of an external effector and owns the tool motor representation, while the intraparietal sulcus extracts its visual features. In these areas, multisensory integration neurons enlarge their receptive fields to embody supernumerary limbs. For operating an anthropomorphic neuroprosthesis, the mirror system is required to understand the meaning of the action, the cerebellum for the formation of its internal model and the insula for its interoception. In conclusion, anthropomorphic sensorized devices can provide the critical sensory afferences to evolve the exploitation of tools through their embodiment, reshaping the body representation and the

  6. Confronting an Augmented Reality

    Science.gov (United States)

    Munnerley, Danny; Bacon, Matt; Wilson, Anna; Steele, James; Hedberg, John; Fitzgerald, Robert

    2012-01-01

    How can educators make use of augmented reality technologies and practices to enhance learning and why would we want to embrace such technologies anyway? How can an augmented reality help a learner confront, interpret and ultimately comprehend reality itself ? In this article, we seek to initiate a discussion that focuses on these questions, and…

  7. Advanced Intellect-Augmentation Techniques.

    Science.gov (United States)

    Engelbart, D. C.

    This progress report covers a two-year project which is part of a program that is exploring the value of computer aids in augmenting human intellectual capability. The background and nature of the program, its resources, and the activities it has undertaken are outlined. User experience in applying augmentation tools and techniques to various…

  8. Cold plate

    Energy Technology Data Exchange (ETDEWEB)

    Marroquin, Christopher M.; O' Connell, Kevin M.; Schultz, Mark D.; Tian, Shurong

    2018-02-13

    A cold plate, an electronic assembly including a cold plate, and a method for forming a cold plate are provided. The cold plate includes an interface plate and an opposing plate that form a plenum. The cold plate includes a plurality of active areas arranged for alignment over respective heat generating portions of an electronic assembly, and non-active areas between the active areas. A cooling fluid flows through the plenum. The plenum, at the non-active areas, has a reduced width and/or reduced height relative to the plenum at the active areas. The reduced width and/or height of the plenum, and exterior dimensions of cold plate, at the non-active areas allow the non-active areas to flex to accommodate surface variations of the electronics assembly. The reduced width and/or height non-active areas can be specifically shaped to fit between physical features of the electronics assembly.

  9. Novel Augmentation Strategies in Major Depression

    DEFF Research Database (Denmark)

    Martiny, Klaus

    2017-01-01

    Hypothesis The hypotheses of all the four included studies share the common idea that it is possible to augment the effect of antidepressant drug treatment by applying different interventions and with each intervention attain a clinically meaningful better effect compared to a control condition...... and randomised to augmentation with either active or placebo matching pindolol tablets. In the PEMF study patients were continued on ongoing medication and randomised to augmentation with active or inactive (sham) 30 minutes daily PEMF treatment on weekdays. In the Chronos study all patients were treated...... The results from the Pindolol study showed that pindolol did not augment the effect of venlafaxine for the whole sample. However, for those patients classified as slow metabolizers, based on their O-desmethylvenlafaxine/venlafaxine ratio (ODV/V), pindolol did augment the antidepressant effect. For patients...

  10. Augmented Reality for Science Education

    DEFF Research Database (Denmark)

    Brandt, Harald; Nielsen, Birgitte Lund; Georgsen, Marianne

    Augmented reality (AR) holds great promise as a learning tool. So far, however, most research has looked at the technology itself – and AR has been used primarily for commercial purposes. As a learning tool, AR supports an inquiry-based approach to science education with a high level of student...... involvement. The AR-sci-project (Augmented Reality for SCIence education) addresses the issue of applying augmented reality in developing innovative science education and enhancing the quality of science teaching and learning....

  11. Physical hypermedia: augmenting physical material with hypermedia structures

    DEFF Research Database (Denmark)

    Grønbæk, Kaj; Ørbæk, Peter; Kristensen, Jannie Friis

    2003-01-01

    This paper introduces the notion of physical hypermedia, addressing the problem of organizing material in mixed digital and physical environments. Based on empirical studies, we propose concepts for collectional actions and meta-data actions, and present prototypes combining principles from...... augmented reality and hypermedia to support organization of mixtures of digital and physical materials. Our prototype of a physical hypermedia system is running on an augmented architect's desk and digital walls utilizing Radio Frequency Identifier (RFID) tags as well as visual tags tracked by cameras....... It allows users to tag physical materials, and have these tracked by readers (antennas) that may become pervasive in our work environments. In the physical hypermedia system, we work with three categories of RFID tags: simple object tags, collectional tags, and tooltags invoking operations such as grouping...

  12. Augmented Reality on Android

    OpenAIRE

    Chunghan Li; Chang-Shyh Peng; Daisy F. Sang

    2013-01-01

    Augmented Reality is an application which combines a live view of real-world environment and computer-generated images. This paper studies and demonstrates an efficient Augmented Reality development in the mobile Android environment with the native Java language and Android SDK. Major components include Barcode Reader, File Loader, Marker Detector, Transform Matrix Generator, and a cloud database.

  13. 3-D subduction dynamics in the western Pacific: Mantle pressure, plate kinematics, and dynamic topography.

    Science.gov (United States)

    Holt, A. F.; Royden, L.; Becker, T. W.; Faccenna, C.

    2017-12-01

    While it is well established that the slab pull of negatively buoyant oceanic plates is the primary driving force of plate tectonics, the dynamic "details" of subduction have proved difficult to pin down. We use the Philippine Sea Plate region of the western Pacific as a site to explore links between kinematic observables (e.g. topography and plate motions) and the dynamics of the subduction system (e.g. mantle flow, mantle pressure). To first order, the Philippine Sea Plate can be considered to be the central plate of a double slab system containing two slabs that dip in the same direction, to the west. This subduction configuration presents the opportunity to explore subduction dynamics in a setting where two closely spaced slabs interact via subduction-induced mantle flow and stresses transmitted through the intervening plate. We use a 3-D numerical approach (e.g. Holt et al., 2017), augmented by semi-analytical models (e.g. Jagoutz et al., 2017), to develop relationships between dynamic processes and kinematic properties, including plate velocities, lithospheric stress state, slab dip angles, and topography. When combined with subduction zone observables, this allows us to isolate the first order dynamic processes that are in operation in the Philippine Sea Plate region. Our results suggest that positive pressure build-up occurs in the asthenosphere between the two slabs (Izu-Bonin-Mariana and Ryukyu-Nankai), and that this is responsible for producing much of the observed kinematic variability in the region, including the steep dip of the Pacific slab at the Izu-Bonin-Mariana trench, as compared to the flat dip of the Pacific slab north of Japan. We then extend our understanding of the role of asthenospheric pressure to examine the forces responsible for the plate kinematics and dynamic topography of the entire Western Pacific subduction margin(s). References:Holt, A. F., Royden, L. H., Becker, T. W., 2017. Geophys. J. Int., 209, 250-265Jagoutz, O., Royden, L

  14. Heat transfer augmentation for high heat flux removal in rib-roughened narrow channels

    International Nuclear Information System (INIS)

    Islam, M.S.; Hino, Ryutaro; Haga, Katsuhiro; Sudo, Yukio; Monde, Masanori.

    1997-03-01

    Heat transfer augmentation in narrow rectangular channels in a target system is a very important method to remove high heat flux up to 12 MW/m 2 generated at target plates of a high-intensity proton accelerator of 1.5 GeV and 1 mA with a proton beam power of 1.5 MW. In this report, heat transfer coefficients and friction factors in narrow rectangular channels with one-sided rib-roughened surface were evaluated for fully developed flows in the range of the Reynolds number from 6,000 to 1,00,000; the rib pitch-to-height ratios (p/k) were 10,20 and 30; the rib height-to-equivalent diameter ratios (k/De) were 0.025, 0.03 and 0.1 by means of previous existing experimental correlations. The rib-roughened surface augmented heat transfer coefficients approximately 4 times higher than the smooth surface at Re=10,000, p/k=10 and k/De=0.1; friction factors increase around 22 times higher. In this case, higher heat flux up to 12 MW/m 2 could be removed from the rib-roughened surface without flow boiling which induces flow instability; but pressure drop reaches about 1.8 MPa. Correlations obtained by air-flow experiments have showed lower heat transfer performance with the water-flow conditions. The experimental apparatus was proposed for further investigation on heat transfer augmentation in very narrow channels under water-flow conditions. This report presents the evaluation results and an outline of the test apparatus. (author)

  15. Comparison among perfect-C®, zero-P®, and plates with a cage in single-level cervical degenerative disc disease.

    Science.gov (United States)

    Noh, Sung Hyun; Zhang, Ho Yeol

    2018-01-25

    We intended to analyze the efficacy of a new integrated cage and plate device called Perfect-C for anterior cervical discectomy and fusion (ACDF) to cure single-level cervical degenerative disc disease. We enrolled 148 patients who were subjected to single-level ACDF with one of the following three surgical devices: a Perfect-C implant (41 patients), a Zero-P implant (36 patients), or a titanium plate with a polyetheretherketone (PEEK) cage (71 patients). We conducted a retrospective study to compare the clinical and radiological results among the three groups. The length of the operation, intraoperative blood loss, and duration of hospitalization were significantly lower in the Perfect-C group than in the Zero-P and plate-with-cage groups (P Zero-P groups but was noted in 21 cases (30%) in the plate-with-cage group. The cephalad and caudal plate-to-disc distance (PDD) and the cephalad and caudal PDD/anterior body height (ABH) were significantly greater in the Perfect-C and Zero-P groups than in the plate-with-cage group (P Zero-P group, and in 15 cases (21%) in the plate-with-cage group. Fusion occurred in 37 cases (90%) in the Perfect-C group, in 31 cases (86%) in the Zero-P group, and in 68 cases (95%) in the plate-with-cage group. The Perfect-C, Zero-P, and plate-with-cage devices are effective for treating single-level cervical degenerative disc disease. However, the Perfect-C implant has many advantages over both the Zero-P implant and conventional plate-cage treatments. The Perfect-C implant was associated with shorter operation times and hospitalization durations, less blood loss, and lower subsidence rates compared with the Zero-P implant or the titanium plate with a PEEK cage.

  16. Augmenting Locomotion in an Anthropomorphic System

    Directory of Open Access Journals (Sweden)

    Derek Wight

    2005-02-01

    Full Text Available A powered orthosis has applications ranging from assisting the elderly to augmenting astronauts. An assistive control scheme is developed that uses the force from a slave actuator to augment the force of a master actuator. This can be used to augment a closed-loop control scheme applied to the master actuator. Initially, actuator augmentation is explored both theoretically and experimentally using a simple mechanical system. The control scheme is then applied to a scale model of human lower limbs on a stationary bicycle to investigate the feasibility of a powered orthosis using pneumatic muscle actuators.

  17. The biomechanical effects of polytetrafluoroethylene suture augmentations in lateral-row rotator cuff repairs in an ovine model.

    Science.gov (United States)

    Beimers, Lijkele; Lam, Patrick H; Murrell, George A C

    2014-10-01

    This study investigated the biomechanical effects of expanded polytetrafluoroethylene (ePTFE) suture augmentation patches in rotator cuff repair constructs. The infraspinatus tendon in 24 cadaveric ovine shoulders was repaired using an inverted horizontal mattress suture with 2 knotless bone anchors (ArthroCare, Austin, TX, USA) in a lateral-row configuration. Four different repair groups (6 per group) were created: (1) standard repair using inverted horizontal mattress sutures, (2) repair with ePTFE suture augmentations on the bursal side of the tendon, (3) repair with ePTFE suture augmentations on the articular side, and, (4) repair with ePTFE suture augmentations on both sides of the tendon. Footprint contact pressure, stiffness, and the load to failure of the repair constructs were measured. Repairs with ePTFE suture augmentations on the bursal side exerted significantly more footprint contact pressure (0.40 ± 0.01 MPa) than those on the articular side (0.34 ± 0.02 MPa, P = .04) and those on both sides (0.33 ± 0.02 MPa, P = .01). At 15 degrees of abduction, ePTFE-augmented repairs on the bursal side had higher footprint contact pressure (0.26 ± 0.03 MPa) compared with standard repairs (0.15 ± 0.02 MPa, P = .01) and with ePTFE-augmented repairs on the articular side (0.18 ± 0.02 MPa, P = .03). The ePTFE-augmented repairs on the bursal side demonstrated significantly higher failure loads (178 ± 18 N) than standard repairs (120 ± 17 N, P = .04). Inverted horizontal mattress sutures augmented with ePTFE patches on the bursal side of the tendon enhanced footprint contact pressures and the ultimate load to failure of lateral-row rotator cuff repairs in an ovine model. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  18. The role of imaging in pediatric bladder augmentation

    Energy Technology Data Exchange (ETDEWEB)

    Breen, Micheal; Chow, Jeanne S. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Phelps, Andrew [UCSF Benioff Children' s Hospital San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Estrada, Carlos [Boston Children' s Hospital, Department of Urology, Boston, MA (United States)

    2015-09-15

    Bladder augmentation (also called augmentation cystoplasty) refers to a number of surgical methods that increase the capacity and compliance of the urinary bladder. Imaging has an important role in the postoperative evaluation of bladder augmentation. The most common augmentation procedures utilize enteric segments to augment the bladder. The various types of bladder augmentation have characteristic appearances on different imaging modalities. Spontaneous bladder perforation is a complication that is seen in both early and late post-operative periods and it is one of the most important complications for radiologists to be aware of as it is life-threatening. We review the indications for bladder augmentation in children, the surgical techniques employed, the normal postoperative appearances on imaging studies and the role of imaging complications of bladder augmentation including delayed spontaneous bladder rupture, which is life-threatening. (orig.)

  19. Repeated vertebral augmentation for new vertebral compression fractures of postvertebral augmentation patients: a nationwide cohort study

    Directory of Open Access Journals (Sweden)

    Liang CL

    2015-03-01

    Full Text Available Cheng-Loong Liang,1 Hao-Kwan Wang,1 Fei-Kai Syu,2 Kuo-Wei Wang,1 Kang Lu,1 Po-Chou Liliang1 1Department of Neurosurgery, E-Da Hospital, I-Shou University, Kaohsiung City, Taiwan; 2Department of Pharmacy, China Medical University Hospital, Taichung City, Taiwan Purpose: Postvertebral augmentation vertebral compression fractures are common; repeated vertebral augmentation is usually performed for prompt pain relief. This study aimed to evaluate the incidence and risk factors of repeat vertebral augmentation.Methods: We performed a retrospective, nationwide, population-based longitudinal observation study, using the National Health Insurance Research Database (NHIRD of Taiwan. All patients who received vertebral augmentation for vertebral compression fractures were evaluated. The collected data included patient characteristics (demographics, comorbidities, and medication exposure and repeat vertebral augmentation. Kaplan–Meier and stratified Cox proportional hazard regressions were performed for analyses.Results: The overall incidence of repeat vertebral augmentation was 11.3% during the follow-up until 2010. Patients with the following characteristics were at greater risk for repeat vertebral augmentation: female sex (AOR=1.24; 95% confidence interval [CI]: 1.10–2.36, advanced age (AOR=1.60; 95% CI: 1.32–2.08, diabetes mellitus (AOR=4.31; 95% CI: 4.05–5.88, cerebrovascular disease (AOR=4.09; 95% CI: 3.44–5.76, dementia (AOR=1.97; 95% CI: 1.69–2.33, blindness or low vision (AOR=3.72; 95% CI: 2.32–3.95, hypertension (AOR=2.58; 95% CI: 2.35–3.47, and hyperlipidemia (AOR=2.09; 95% CI: 1.67–2.22. Patients taking calcium/ vitamin D (AOR=2.98; 95% CI: 1.83–3.93, bisphosphonates (AOR=2.11; 95% CI: 1.26–2.61, or calcitonin (AOR=4.59; 95% CI: 3.40–5.77 were less likely to undergo repeat vertebral augmentation; however, those taking steroids (AOR=7.28; 95% CI: 6.32–8.08, acetaminophen (AOR=3.54; 95% CI: 2.75–4.83, or nonsteroidal

  20. Hybrid-augmented intelligence:collaboration and cognition

    Institute of Scientific and Technical Information of China (English)

    Nan-ning ZHENG; Zi-yi LIU; Peng-ju REN; Yong-qiang MA; Shi-tao CHEN; Si-yu YU; Jian-ru XUE

    2017-01-01

    The long-term goal of artificial intelligence (AI) is to make machines learn and think like human beings. Due to the high levels of uncertainty and vulnerability in human life and the open-ended nature of problems that humans are facing, no matter how intelligent machines are, they are unable to completely replace humans. Therefore, it is necessary to introduce human cognitive capabilities or human-like cognitive models into AI systems to develop a new form of AI, that is, hybrid-augmented intelligence. This form of AI or machine intelligence is a feasible and important developing model. Hybrid-augmented intelligence can be divided into two basic models:one is human-in-the-loop augmented intelligence with human-computer collaboration, and the other is cognitive computing based augmented intelligence, in which a cognitive model is embedded in the machine learning system. This survey describes a basic framework for human-computer collaborative hybrid-augmented intelligence, and the basic elements of hybrid-augmented intelligence based on cognitive computing. These elements include intuitive reasoning, causal models, evolution of memory and knowledge, especially the role and basic principles of intuitive reasoning for complex problem solving, and the cognitive learning framework for visual scene understanding based on memory and reasoning. Several typical applications of hybrid-augmented intelligence in related fields are given.

  1. ARSC: Augmented Reality Student Card--An Augmented Reality Solution for the Education Field

    Science.gov (United States)

    El Sayed, Neven A. M.; Zayed, Hala H.; Sharawy, Mohamed I.

    2011-01-01

    Augmented Reality (AR) is the technology of adding virtual objects to real scenes through enabling the addition of missing information in real life. As the lack of resources is a problem that can be solved through AR, this paper presents and explains the usage of AR technology we introduce Augmented Reality Student Card (ARSC) as an application of…

  2. PENGARUH MEDIA PEMBELAJARAN BERBASIS AUGMENTED REALITY TERHADAP HASIL BELAJAR SISWA KELAS X PADA KONSEP DINAMIKA PARTIKEL

    Directory of Open Access Journals (Sweden)

    Iwan Permana Suwarna

    2016-02-01

    Full Text Available Abstract: This research aims to determine the effect of learning media based on Augmented Reality to learning outcome of students 10th grade on the concept particle dynamics. This research was done in 10th grade science class: 2 and 4 in SMA 67 Jakarta. The research was done in October-November 2013. The research method is a quasi experimental with a noneqiuvalent control group design and the sampling technique is purposive. Instruments of the research are test (multiple choices and non test(questionnaire. Data were analyzed quantitatively using the t test, questionare analyzed qualitatively. The conclution : there is the influence of augmented reality-based instructional media on learning outcome of students grade 10th on the concept particle dynamics. Average learning outcome experiment group is higher than control group. The experimental group superior on cognitive level (C1-C4. Carrying capacity of the media Augmented Reality on the learning process had teacher done is excellent category (83.24 %. DOI: 10.15408/tjems.v1i1.1111

  3. Effects of long-term balance training with vibrotactile sensory augmentation among community-dwelling healthy older adults: a randomized preliminary study.

    Science.gov (United States)

    Bao, Tian; Carender, Wendy J; Kinnaird, Catherine; Barone, Vincent J; Peethambaran, Geeta; Whitney, Susan L; Kabeto, Mohammed; Seidler, Rachael D; Sienko, Kathleen H

    2018-01-18

    Sensory augmentation has been shown to improve postural stability during real-time balance applications. Limited long-term controlled studies have examined retention of balance improvements in healthy older adults after training with sensory augmentation has ceased. This pilot study aimed to assess the efficacy of long-term balance training with and without sensory augmentation among community-dwelling healthy older adults. Twelve participants (four males, eight females; 75.6 ± 4.9 yrs) were randomly assigned to the experimental group (n = 6) or control group (n = 6). Participants trained in their homes for eight weeks, completing three 45-min exercise sessions per week using smart phone balance trainers that provided written, graphic, and video guidance, and monitored trunk sway. During each session, participants performed six repetitions of six exercises selected from five categories (static standing, compliant surface standing, weight shifting, modified center of gravity, and gait). The experimental group received vibrotactile sensory augmentation for four of the six repetitions per exercise via the smart phone balance trainers, while the control group performed exercises without sensory augmentation. The smart phone balance trainers sent exercise performance data to a physical therapist, who recommended exercises on a weekly basis. Balance performance was assessed using a battery of clinical balance tests (Activity Balance Confidence Scale, Sensory Organization Test, Mini Balance Evaluation Systems Test, Five Times Sit to Stand Test, Four Square Step Test, Functional Reach Test, Gait Speed Test, Timed Up and Go, and Timed Up and Go with Cognitive Task) before training, after four weeks of training, and after eight weeks of training. Participants in the experimental group were able to use vibrotactile sensory augmentation independently in their homes. After training, the experimental group had significantly greater improvements in Sensory

  4. Mersiline mesh in premaxillary augmentation.

    Science.gov (United States)

    Foda, Hossam M T

    2005-01-01

    Premaxillary retrusion may distort the aesthetic appearance of the columella, lip, and nasal tip. This defect is characteristically seen in, but not limited to, patients with cleft lip nasal deformity. This study investigated 60 patients presenting with premaxillary deficiencies in which Mersiline mesh was used to augment the premaxilla. All the cases had surgery using the external rhinoplasty technique. Two methods of augmentation with Mersiline mesh were used: the Mersiline roll technique, for the cases with central symmetric deficiencies, and the Mersiline packing technique, for the cases with asymmetric deficiencies. Premaxillary augmentation with Mersiline mesh proved to be simple technically, easy to perform, and not associated with any complications. Periodic follow-up evaluation for a mean period of 32 months (range, 12-98 months) showed that an adequate degree of premaxillary augmentation was maintained with no clinically detectable resorption of the mesh implant.

  5. Augmented Reality-Guided Lumbar Facet Joint Injections.

    Science.gov (United States)

    Agten, Christoph A; Dennler, Cyrill; Rosskopf, Andrea B; Jaberg, Laurenz; Pfirrmann, Christian W A; Farshad, Mazda

    2018-05-08

    The aim of this study was to assess feasibility and accuracy of augmented reality-guided lumbar facet joint injections. A spine phantom completely embedded in hardened opaque agar with 3 ring markers was built. A 3-dimensional model of the phantom was uploaded to an augmented reality headset (Microsoft HoloLens). Two radiologists independently performed 20 augmented reality-guided and 20 computed tomography (CT)-guided facet joint injections each: for each augmented reality-guided injection, the hologram was manually aligned with the phantom container using the ring markers. The radiologists targeted the virtual facet joint and tried to place the needle tip in the holographic joint space. Computed tomography was performed after each needle placement to document final needle tip position. Time needed from grabbing the needle to final needle placement was measured for each simulated injection. An independent radiologist rated images of all needle placements in a randomized order blinded to modality (augmented reality vs CT) and performer as perfect, acceptable, incorrect, or unsafe. Accuracy and time to place needles were compared between augmented reality-guided and CT-guided facet joint injections. In total, 39/40 (97.5%) of augmented reality-guided needle placements were either perfect or acceptable compared with 40/40 (100%) CT-guided needle placements (P = 0.5). One augmented reality-guided injection missed the facet joint space by 2 mm. No unsafe needle placements occurred. Time to final needle placement was substantially faster with augmented reality guidance (mean 14 ± 6 seconds vs 39 ± 15 seconds, P Augmented reality-guided facet joint injections are feasible and accurate without potentially harmful needle placement in an experimental setting.

  6. Nickel Coatings and Electroforming Using Pulse Reversal Plating

    DEFF Research Database (Denmark)

    Tang, Peter Torben; Dylmer, Henrik; Møller, Per

    1995-01-01

    Introducing pulse plating brings new life and possibilities to one the oldest groups of electroplating processes. Nickel coatings and electroforming are used in a great variety of products, from oil valves to optical discs, and for many applications such as corrosion protection and micro-mechanic......Introducing pulse plating brings new life and possibilities to one the oldest groups of electroplating processes. Nickel coatings and electroforming are used in a great variety of products, from oil valves to optical discs, and for many applications such as corrosion protection and micro...

  7. Primary stability of different plate positions and the role of bone substitute in open wedge high tibial osteotomy.

    Science.gov (United States)

    Takeuchi, Ryohei; Woon-Hwa, Jung; Ishikawa, Hiroyuki; Yamaguchi, Yuichiro; Osawa, Katsunari; Akamatsu, Yasushi; Kuroda, Koichi

    2017-12-01

    The purpose of this study was to compare the mechanical fixation strengths of anteromedial and medial plate positions in osteotomy, and clarify the effects of bone substitute placement into the osteotomy site. Twenty-eight sawbone tibia models were used. Four different models were prepared: Group A, the osteotomy site was open and the plate position was anteromedial; Group B, bone substitutes were inserted into the osteotomy site and the plate position was anteromedial; Group C, the osteotomy site was open and the plate position was medial; and Group D, bone substitutes were inserted into the osteotomy site and the plate position was medial. The loading condition ranged from 0 to 800N and one hertz cycles were applied. Changes of the tibial posterior slope angle (TPS), stress on the plate and lateral hinge were measured. The changes in the TPS and the stress on the plate were significantly larger in Group A than in Group C. These were significantly larger in Group A than in Group B, and in Group C than in Group D. There was no significant difference between Group B and Group D, and no significant difference between knee flexion angles of 0° and 10°. Stress on the lateral hinge was significantly smaller when bone substitute was used. A medial plate position was biomechanically superior to an anteromedial position if bone substitute was not used. Bone substitute distributed the stress concentration around the osteotomy gap and prevented an increase in TPS angle regardless of the plate position. Copyright © 2017. Published by Elsevier B.V.

  8. Augmented marked graphs

    CERN Document Server

    Cheung, King Sing

    2014-01-01

    Petri nets are a formal and theoretically rich model for the modelling and analysis of systems. A subclass of Petri nets, augmented marked graphs possess a structure that is especially desirable for the modelling and analysis of systems with concurrent processes and shared resources.This monograph consists of three parts: Part I provides the conceptual background for readers who have no prior knowledge on Petri nets; Part II elaborates the theory of augmented marked graphs; finally, Part III discusses the application to system integration. The book is suitable as a first self-contained volume

  9. Biomechanical comparison of supraacetabular external fixation and anterior pelvic bridge plating.

    Science.gov (United States)

    Çavuşoğlu, Ali Turgay; Erbay, Fatma Kübra; Özsoy, Mehmet Hakan; Demir, Teyfik

    2017-10-01

    Unstable pelvic ring injuries are complex and risky injuries due to high morbidity and mortality. Although anterior pelvic external fixator is a suitable method for rapid stabilization of an injured pelvic ring, due to some disadvantages such as high complication rate, nerve damage, and difficulties of patient's mobility and comfort, there has recently been increased searching for alternative methods for stabilization of the pelvic ring. Pubic symphysis zone freely moves in pelvic models. This study aims to evaluate the biomechanical stability of anterior pelvic bridge plating and compare it with supraacetabular external fixators in an untreated unstable pelvic fracture model. Samples were loaded statically with 2-mm/min loading rate in single leg standing position. Maximum load was 2.3 kN. When loading the samples, photographs were taken continuously. Stiffness values were calculated from the load displacement curves. Some reference parameters were described and were measured from unloaded and 2.3-kN-loaded photographs of the test. The mean stiffness values were 491.14 ± 52.22, 478.55 ± 41.44, and 470.25 ± 44.51 N/mm for anterior pelvic bridge plating group, supraacetabular external fixator group, and Control group, respectively. According to the measured parameters from photographs, the mean displacement at the pubic symphysis was 4.7 ± 0.32, 15.8 ± 2.01, and 18.2 ± 0.47 mm for anterior pelvic bridge plating, supraacetabular external fixator, and Control group, respectively. The highest displacement in the pubic symphysis was found in Control group, and minimum displacement was observed in anterior pelvic bridge plating group. When the perpendicular distance between the right and left lower end of ischium was examined, it was observed that displacement was minimum in anterior pelvic bridge plating group compared to other two groups, regarding to the high stability of pubic symphysis. In conclusion, this study revealed

  10. Minimally invasive plating osteosynthesis for mid-distal third humeral shaft fractures.

    Science.gov (United States)

    Lian, Kejian; Wang, Lei; Lin, Dasheng; Chen, Zhiwen

    2013-08-01

    Mid-distal third humeral shaft fractures can be effectively treated with minimally invasive plating osteosynthesis and intramedullary nailing (IMN). However, these 2 treatments have not been adequately compared. Forty-seven patients (47 fractures) with mid-distal third humeral shaft fractures were randomly allocated to undergo either minimally invasive plating osteosynthesis (n=24) or IMN (n=23). The 2 groups were similar in terms of fracture patterns, fracture location, age, and associated injuries. Intraoperative measurements included blood loss and operative time. Clinical outcome measurements included fracture healing, radial nerve recovery, and elbow and shoulder discomfort. Radiographic measurements included fracture alignment, time to healing, delayed union, and nonunion. Functional outcome was satisfactory in both groups. Mean American Shoulder and Elbow Surgeons score and Mayo score were both better for the minimally invasive plating osteosynthesis group than for the IMN group (98.2 vs 97.6, respectively, and 93.5 vs 94.1, respectively; Pshaft fractures. Minimally invasive plating osteosynthesis is more suitable for complex fractures, especially for radial protection and motion recovery of adjacent joints, compared with IMN for simple fractures. Copyright 2013, SLACK Incorporated.

  11. Electroless metal plating of plastics

    Science.gov (United States)

    Krause, L.J.

    1982-09-20

    Process for plating main group metals on aromatic polymers is carried out by the use of a nonaqueous solution of a salt of an alkali metal in a positive valence state and a main group metal in a negative valence state with contact between the solution and polymer providing a redox reaction causing the deposition of the main group metal and the reduction of the polymer. Products from the process exhibit useful decorative and electrical properties.

  12. Fuel cell plates with skewed process channels for uniform distribution of stack compression load

    Science.gov (United States)

    Granata, Jr., Samuel J.; Woodle, Boyd M.

    1989-01-01

    An electrochemical fuel cell includes an anode electrode, a cathode electrode, an electrolyte matrix sandwiched between electrodes, and a pair of plates above and below the electrodes. The plate above the electrodes has a lower surface with a first group of process gas flow channels formed thereon and the plate below the electrodes has an upper surface with a second group of process gas flow channels formed thereon. The channels of each group extend generally parallel to one another. The improvement comprises the process gas flow channels on the lower surface of the plate above the anode electrode and the process gas flow channels on the upper surface of the plate below the cathode electrode being skewed in opposite directions such that contact areas of the surfaces of the plates through the electrodes are formed in crisscross arrangements. Also, the plates have at least one groove in areas of the surfaces thereof where the channels are absent for holding process gas and increasing electrochemical activity of the fuel cell. The groove in each plate surface intersects with the process channels therein. Also, the opposite surfaces of a bipolar plate for a fuel cell contain first and second arrangements of process gas flow channels in the respective surfaces which are skewed the same amount in opposite directions relative to the longitudinal centerline of the plate.

  13. Irradiation of full size UMo plates

    International Nuclear Information System (INIS)

    Vacelet, H.; Lavastre, Y.; Grasse, M.; Sacristan, P.; Languille, A.

    1999-01-01

    An important development program for a UMo MTR fuel has been launched in France. The goal of the French working group is to develop a high performing and reprocessable fuel before the end of the US return policy. This paper is focussed on the fabrication of full-sized UMo plates with LEU (Low Enriched Enrichment) and their irradiation in OSIRIS reactor which was started on the 22nd of September. The results of the plates inspection are presented here as well as the irradiation conditions. (author)

  14. Is ridge preservation/augmentation at periodontally compromised extraction sockets safe? A retrospective study.

    Science.gov (United States)

    Kim, Jung-Ju; Ben Amara, Heithem; Schwarz, Frank; Kim, Hae-Young; Lee, Jung-Won; Wikesjö, Ulf M E; Koo, Ki-Tae

    2017-10-01

    This study aimed to evaluate the safety of ridge preservation/augmentation procedures when performed at compromised extraction sockets. Patients subject to ridge preservation/augmentation at periodontally compromised sockets at Seoul National University Dental Hospital (SNUDH) were evaluated in a chart review. Tooth extractions due to acute infection were not included in our study as chronically formed lesions are the only lesions that can be detected from radiographic images. If inflammatory symptoms persisted following ridge preservation/augmentation and antimicrobial and anti-inflammatory therapy, the patient was categorized as a re-infection case and implanted biomaterial removed. Of 10,060 patients subject to tooth extractions at SNUDH, 2011 through 2015, 297 cases meeting inclusion criteria were reviewed. The severity and type of lesions were not specific because extracting data was only done by radiographic images and chart records. The review identified eight patients exhibiting inflammatory symptoms that required additional antimicrobial and anti-inflammatory therapy. Within this group, re-infection occurred in two patients requiring biomaterials removal. The final safety rate for the ridge preservation/augmentation was 99.3%. None of the demographic factors, systemic conditions or choice of biomaterial affected the safety of ridge preservation/augmentation. Alveolar ridge preservation/augmentation at periodontally compromised sockets appears safe following thorough removal of infectious source. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Outcome of Large to Massive Rotator Cuff Tears Repaired With and Without Extracellular Matrix Augmentation: A Prospective Comparative Study.

    Science.gov (United States)

    Gilot, Gregory J; Alvarez-Pinzon, Andres M; Barcksdale, Leticia; Westerdahl, David; Krill, Michael; Peck, Evan

    2015-08-01

    To compare the results of arthroscopic repair of large to massive rotator cuff tears (RCTs) with or without augmentation using an extracellular matrix (ECM) graft and to present ECM graft augmentation as a valuable surgical alternative used for biomechanical reinforcement in any RCT repair. We performed a prospective, blinded, single-center, comparative study of patients who underwent arthroscopic repair of a large to massive RCT with or without augmentation with ECM graft. The primary outcome was assessed by the presence or absence of a retear of the previously repaired rotator cuff, as noted on ultrasound examination. The secondary outcomes were patient satisfaction evaluated preoperatively and postoperatively using the 12-item Short Form Health Survey, the American Shoulder and Elbow Surgeons shoulder outcome score, a visual analog scale score, the Western Ontario Rotator Cuff index, and a shoulder activity level survey. We enrolled 35 patients in the study: 20 in the ECM-augmented rotator cuff repair group and 15 in the control group. The follow-up period ranged from 22 to 26 months, with a mean of 24.9 months. There was a significant difference between the groups in terms of the incidence of retears: 26% (4 retears) in the control group and 10% (2 retears) in the ECM graft group (P = .0483). The mean pain level decreased from 6.9 to 4.1 in the control group and from 6.8 to 0.9 in the ECM graft group (P = .024). The American Shoulder and Elbow Surgeons score improved from 62.1 to 72.6 points in the control group and from 63.8 to 88.9 points (P = .02) in the treatment group. The mean Short Form 12 scores improved in the 2 groups, with a statistically significant difference favoring graft augmentation (P = .031), and correspondingly, the Western Ontario Rotator Cuff index scores improved in both arms, favoring the treatment group (P = .0412). The use of ECM for augmentation of arthroscopic repairs of large to massive RCTs reduces the incidence of retears

  16. A 2-year follow-up study of patients participating in our transcranial pulsating electromagnetic fields augmentation in treatment-resistant depression

    DEFF Research Database (Denmark)

    Bech, Per; Lindberg, Lone; Straasø, Birgit

    2015-01-01

    OBJECTIVE: We have made a 2-year follow-up study to evaluate the effect of repeated transcranial pulsating electromagnetic fields (T-PEMF) augmentation in patients who had achieved remission but later on relapsed, as well as to identify factors contributing to treatment-resistant depression......: In group A, comprising 27 patients, 13 had relapsed; they obtained a clear remission after a repeated course of T-PEMF augmentation. In group D, comprising 16 patients, we identified misdiagnostic factors both concerning the event of remission after the previous T-PEMF augmentation and concerning...... with the first series of T-PEMF. Treatment-resistant depression is a condition that has a high degree of multivariate problems. Misuse of alcohol or drugs, severe somatic disorders and other psychosocial problems may need other kinds of treatment before T-PEMF augmentation....

  17. Titanium mesh as a low-profile alternative for tension-band augmentation in patella fracture fixation: A biomechanical study.

    Science.gov (United States)

    Dickens, Aaron J; Salas, Christina; Rise, LeRoy; Murray-Krezan, Cristina; Taha, Mahmoud Reda; DeCoster, Thomas A; Gehlert, Rick J

    2015-01-01

    We performed a simple biomechanical study to compare the fixation strength of titanium mesh with traditional tension-band augmentation, which is a standard treatment for transverse patella fractures. We hypothesised that titanium mesh augmentation is not inferior in fixation strength to the standard treatment. Twenty-four synthetic patellae were tested. Twelve were fixed with stainless steel wire and parallel cannulated screws. Twelve were fixed with parallel cannulated screws, augmented with anterior titanium mesh and four screws. A custom test fixture was developed to simulate a knee flexed to 90°. A uniaxial force was applied to the simulated extensor mechanism at this angle. A non-inferiority study design was used to evaluate ultimate force required for failure of each construct as a measure of fixation strength. Stiffness of the bone/implant construct, fracture gap immediately prior to failure, and modes of failure are also reported. The mean difference in force at failure was -23.0 N (95% CI: -123.6 to 77.6N) between mesh and wire constructs, well within the pre-defined non-inferiority margin of -260 N. Mean stiffness of the mesh and wire constructs were 19.42 N/mm (95% CI: 18.57-20.27 N/mm) and 19.49 N/mm (95% CI: 18.64-20.35 N/mm), respectively. Mean gap distance for the mesh constructs immediately prior to failure was 2.11 mm (95% CI: 1.35-2.88 mm) and 3.87 mm (95% CI: 2.60-5.13 mm) for wire constructs. Titanium mesh augmentation is not inferior to tension-band wire augmentation when comparing ultimate force required for failure in this simplified biomechanical model. Results also indicate that stiffness of the two constructs is similar but that the mesh maintains a smaller fracture gap prior to failure. The results of this study indicate that the use of titanium mesh plating augmentation as a low-profile alternative to tension-band wiring for fixation of transverse patella fractures warrants further investigation. Copyright © 2015 Elsevier Ltd. All

  18. Chin augmentation

    Science.gov (United States)

    ... or bigger compared to the nose. The best candidates for chin augmentation are people with weak or ... www.urac.org). URAC's accreditation program is an independent audit to verify that A.D.A.M. ...

  19. Operative treatment of intra-articular calcaneal fractures with calcaneal plates and its complications

    Directory of Open Access Journals (Sweden)

    Rak Vaclav

    2009-01-01

    Full Text Available Background: In a retrospective study we analysed intra-articular calcaneal fracture treatment by comparing results and complications related to fracture stabilization with nonlocking calcaneal plates and locking compression plates. Materials and Methods: We performed 76 osteosynthesis (67 patients of intra-articular calcaneal fractures using the standard extended lateral approach from February 2004 to October 2007. Forty-two operations using nonlocking calcaneal plates (group A were performed during the first three years, and 34 calcaneal fractures were stabilized using locking compression plates (group B in 2007. In the Sanders type IV fractures, reconstruction of the calcaneal shape was attempted. Depending on the type of late complication, we performed subtalar arthroscopy in six cases, arthroscopically assisted subtalar distraction bone block arthrodesis in six cases, and plate removal with lateral-wall decompression in five cases. The patients were evaluated by the AOFAS Ankle-Hindfoot Scale. Results: Wound healing complications were 7/42 (17% in group A and 1/34 (3% in group B. No patient had deep osseous infection or foot rebound compartment syndrome. Preoperative size of Bφhler´s angle correlated with postoperative clinical results in both groups. There were no late complications necessitating corrective procedure or arthroscopy until December 2008 in Group B. All late complications ccurred in Group A. The overall results according to the AOFAS Ankle Hindfoot Scale were good or excellent in 23/42 (55% in group A and in 30/34 (85% in group B. Conclusion: Open reduction and internal fixation of intra-articular calcaneal fractures has become a standard surgical method. Fewer complications and better results related to treatment with locking compression plates confirmed in comparison to nonlocking ones were noted for all Sanders types of intra-articular calcaneal fractures. Age and Sanders type IV fractures are not considered to be the

  20. Prototyping Augmented Reality

    CERN Document Server

    Mullen, Tony

    2011-01-01

    Learn to create augmented reality apps using Processing open-source programming language Augmented reality (AR) is used all over, and you may not even realize it. Smartphones overlay data onto live camera views to show homes for sale, restaurants, or historical sites. American football broadcasts use AR to show the invisible first-down line on the field to TV viewers. Nike and Budweiser, among others, have used AR in ads. Now, you can learn to create AR prototypes using 3D data, Processing open-source programming language, and other languages. This unique book is an easy-to-follow guide on how

  1. Radiation shielding plate

    International Nuclear Information System (INIS)

    Kobayashi, Torakichi; Sugawara, Takeo.

    1983-01-01

    Purpose: To reduce the weight and stabilize the configuration of a radiation shielding plate which is used in close contact with an object to be irradiated with radiation rays. Constitution: The radiation shielding plate comprises a substrate made of lead glass and a metallic lead coating on the surface of the substrate by means of plating, vapor deposition or the like. Apertures for permeating radiation rays are formed to the radiation shielding plate. Since the shielding plate is based on a lead glass plate, a sufficient mechanical strength can be obtained with a thinner structure as compared with the conventional plate made of metallic lead. Accordingly, if the shielding plate is disposed on a soft object to be irradiated with radiation rays, the object and the plate itself less deform to obtain a radiation irradiation pattern with distinct edges. (Moriyama, K.)

  2. Plating on difficult-to-plate metals: what's new

    International Nuclear Information System (INIS)

    Wiesner, H.J.

    1980-01-01

    Some of the changes since 1970 in procedures for plating on such materials as titanium, molybdenum, silicon, aluminum, and gallium arsenide are summarized. While basic procedures for plating some of these materials were developed as many as 30 to 40 years ago, changes in the end uses of the plated products have necessitated new plating processes. In some cases, vacuum techniques - such as ion bombardment, ion implantation, and vacuum metallization - have been introduced to improve the adhesion of electrodeposits. In other cases, these techniques have been used to deposit materials upon which electrodeposits are required

  3. Augmented reality som wearable technology

    DEFF Research Database (Denmark)

    Rahn, Annette

    “How Augmented reality can facilitate learning in visualizing human anatomy “ At this station I demonstrate how Augmented reality can be used to visualize the human lungs in situ and as a wearable technology which establish connection between body, image and technology in education. I will show...

  4. Psychosocial characteristics and motivational factors in woman seeking cosmetic breast augmentation surgery

    Directory of Open Access Journals (Sweden)

    Nikolić Jelena

    2013-01-01

    Full Text Available Background/Aim. There are various opinions regarding the factors motivating women to undergo breast augmentation. The aim of this study was to estimate motivation for augmentation mammaplasty (AM, self-esteem and body image perception in breast augmentation patients. Methods. This prospective study involved AM patients operated in the Clinical Center of Vojvodina during a 3-year period. A total of 45 patients responded to our package of questionnaires designed to assess motivation for surgery, self-esteem level and body image perception. Those patients were compared to the control group of women who did not want to change their breast size, and who were similar in their age, social status and education level. Our package of questionnaires included a general questionnaire, Photographic Figure Rating Scale (PFRS and Rosenberg’s Self-Esteem Scale. Results. Differences in marital status, educational level, habitation and employment status were statistically insignificant, but there was a significantly lower body mass index (BMI in the operated women. Considering motives for surgery, a few factors were distinguished: desire to feel more feminine (82.2%, confident (75.5% and attractive (73.3%, to feel less shy with men (64.4%, to improve their sex life (46.5%, teasing history (42.2% and easier to find a partner (11.1% and job (2.2%. Both groups demonstrated a high self-esteem level, but in the AM group results were lower than in the control group. The mean current self-rating by the PFRS in the group AM was lower than in the control group (4.28 ± 1.3 vs 5.12 ± 1.23, respectively and this coincided with lower BMI in the AM group. The women in the AM group had chosen significantly smaller body size as maximally attractive, and had chosen a narrower attractive body size range than the women in the control group. Conclusion. Preoperative evaluation of patients’ motives for surgery can help surgeons to exclude woman with unrealistic expectations and

  5. Psychosocial characteristics and motivational factors in woman seeking cosmetic breast augmentation surgery.

    Science.gov (United States)

    Nikolić, Jelena; Janjić, Zlata; Marinković, Marija; Petrović, Jelica; Bozić, Teodora

    2013-10-01

    There are various opinions regarding the factors motivating women to undergo breast augmentation. The aim of this study was to estimate motivation for augmentation mammaplasty (AM), self-esteem and body image perception in breast augmentation patients. This prospective study involved AM patients operated in the Clinical Center of Vojvodina during a 3-year period. A total of 45 patients responded to our package of questionnaires designed to assess motivation for surgery, self-esteem level and body image perception. Those patients were compared to the control group of women who did not want to change their breast size, and who were similar in their age, social status and education level. Our package of questionnaires included a general questionnaire, Photographic Figure Rating Scale (PFRS) and Rosenberg's Self-Esteem Scale. Differences in marital status, educational level, habitation and employment status were statistically insignificant, but there was a significantly lower body mass index (BMI) in the operated women. Considering motives for surgery, a few factors were distinguished: desire to feel more feminine (82.2%), confident (75.5%) and attractive (73.3%), to feel less shy with men (64.4%), to improve their sex life (46.5%), teasing history (42.2%) and easier to find a partner (11.1%) and job (2.2%). Both groups demonstrated a high self-esteem level, but in the the AM group results were lower than in the control group. The mean current self-rating by the PFRS in the group AM was lower than in the control group (4.28 +/- 1.3 vs 5.12 +/- 1.23, respectively) and this coincided with lower BMI in the AM group. The women in the AM group had chosen significantly smaller body size as maximally attractive, and had chosen a narrower attractive body size range than the women in the control group. CONCLUSION. Preoperative evaluation of patients' motives for surgery can help surgeons to exclude woman with unrealistic expectations and different psychological problems.

  6. Effect of plate shapes in orifice plate type flowmeters

    International Nuclear Information System (INIS)

    Moeller, S.V.

    1984-01-01

    The study of unusual plate shapes in orifice plate type flowmeters is presented, with a view to providing data for the substitution of the plate with one centered circular orifice in those applications where its use is not possible. For this purpose, six pairs of plates with different forms, with and without chamfered edges, were made and tested in a closed water loop. Results show that, generally, the use of chamfers improves the results and, in the case of perforated and slotlike orificed plates, the narrow-ness of the fluid passage tends to make unnecessary its use. (Author) [pt

  7. Plating laboratory

    International Nuclear Information System (INIS)

    Seamster, A.G.; Weitkamp, W.G.

    1984-01-01

    The lead plating of the prototype resonator has been conducted entirely in the plating laboratory at SUNY Stony Brook. Because of the considerable cost and inconvenience in transporting personnel and materials to and from Stony Brook, it is clearly impractical to plate all the resonators there. Furthermore, the high-beta resonator cannot be accommodated at Stony Brook without modifying the set up there. Consequently the authors are constructing a plating lab in-house

  8. Augmented reality in bone tumour resection: An experimental study.

    Science.gov (United States)

    Cho, H S; Park, Y K; Gupta, S; Yoon, C; Han, I; Kim, H-S; Choi, H; Hong, J

    2017-03-01

    We evaluated the accuracy of augmented reality (AR)-based navigation assistance through simulation of bone tumours in a pig femur model. We developed an AR-based navigation system for bone tumour resection, which could be used on a tablet PC. To simulate a bone tumour in the pig femur, a cortical window was made in the diaphysis and bone cement was inserted. A total of 133 pig femurs were used and tumour resection was simulated with AR-assisted resection (164 resection in 82 femurs, half by an orthropaedic oncology expert and half by an orthopaedic resident) and resection with the conventional method (82 resection in 41 femurs). In the conventional group, resection was performed after measuring the distance from the edge of the condyle to the expected resection margin with a ruler as per routine clinical practice. The mean error of 164 resections in 82 femurs in the AR group was 1.71 mm (0 to 6). The mean error of 82 resections in 41 femurs in the conventional resection group was 2.64 mm (0 to 11) (p Augmented reality in bone tumour resection: An experimental study. Bone Joint Res 2017;6:137-143. © 2017 Cho et al.

  9. Directional bending wave propagation in periodically perforated plates

    DEFF Research Database (Denmark)

    Andreassen, Erik; Manktelow, Kevin; Ruzzene, Massimo

    2015-01-01

    We report on the investigation of wave propagation in a periodically perforated plate. A unit cell with double-C perforations is selected as a test article suitable to investigate two-dimensional dispersion characteristics, group velocities, and internal resonances. A numerical model, formulated...... using Mindlin plate elements, is developed to predict relevant wave characteristics such as dispersion, and group velocity variation as a function of frequency and direction of propagation. Experimental tests are conducted through a scanning laser vibrometer, which provides full wave field information...... for the design of phononic waveguides with directional and internal resonant characteristics....

  10. [Case control study on the treatment of acromioclavicular dislocation with Endobutton plates combined with an anchor].

    Science.gov (United States)

    Hu, Jin-Tao; Lu, Jian-Wei; Fu, Li-Feng

    2016-09-25

    To compare the clinical effect of Endobutton plates combined with an anchor and clavicle hook plate in the treatment of acromioclavicular dislocation. From January 2012 to August 2014, 83 patients with Rockwood type III acromioclavicular dislocation underwent surgical treatments. Among them, 34 patients were treated with Endobutton plate and anchor repair(Endobutton group), including 23 males and 11 females, and the mean age was(39.0±6.3) years old (26 to 51 years old); the average time from injury to operation was(4.1±1.3) days(3 to 7 days);the injured side:14 left, 20 right; the dislocation in 28 patients dues to fall, 6 patients dues traffic accident. There were 49 patients treated with clavicular hook plate(hook plate group), including 33 males and 16 females;the mean age was(37.9±6.3) years old (27 to 53 years old); the average time from injury to operation was(4.1±1.1) days (2 to 7 days);the injured side: 18 left, 31 right;the dislication in 36 patients dues to fall, 13 patients dues traffic accidents. The indexes such as intraoperative bleeding volume, operation time, incision size, postoperative complication and postoperative coracoclavicular space, shoulder joint function, and life quality were compared between two groups. In the hook plate group with 49 patients, the plates in 43 patients were removed at the secondary operation, and 32 patients had shoulder pain or limited active range. Thirty four patients in the Endobutton group had no pain symptoms and limited active range. All the patients did not suffer acromioclavicular dislocation again. There was no significant difference between the two groups in operation time, and intraoperative bleeding volume( P >0.05). The incision length in the hook plate group was longer than that in Endobutton group( P 0.05). There were no significant differences of Constant score and SF-36 between two groups 2 months after operation( P >0.05). Sixteen months after operation, the Constant score in the injured side of

  11. Usefulness of polyetheretherketone (PEEK) cage with plate augmentation for anterior arthrodesis in traumatic cervical spine injury.

    Science.gov (United States)

    Song, Kyung-Jin; Choi, Byung-Wan; Kim, Gyu-Hyung; Song, Ji-Hun

    2010-01-01

    Even though many clinical reports about cages have been documented in patients with degenerative disorders, reports were scarce for traumatic injury cases, and those cases using metal cages were restricted to only one-level injury. To evaluate the usefulness of polyetheretherketone (PEEK) cage and plate construction in anterior interbody fusions (AIF) for traumatic cervical spine injuries by analyzing radiographic changes and clinical outcomes. Retrospective study. Fifty-eight patients (91 levels) underwent cage and plate construction for treatment of traumatic cervical spine injury. The fusion rate, fusion time, changes of Cobb angle, subsidence rate, and adjacent level changes were assessed as a radiographic outcome. Clinical analysis includes the recovery rate on the American Spinal Injury Association (ASIA) impairment scale and the presence of the complications. We evaluated 58 patients (91 levels) who underwent surgery and had at least 24 months in follow-up study. Radiographic evaluation included the assessment of interbody fusion rate, fusion time, changes of Cobb angle, subsidence rate, and adjacent level changes. Clinical assessment was done by analyzing recovery state of ASIA impairment scale from preoperative period to the last follow-up and by evaluating complications. Fifty-four cases showed bony fusion within 3 months after the surgery. The mean Cobb angle between the vertebral bodies was 2.54 degrees before operation, 9.13 degrees after operation, and 8.39 degrees at the latest follow-up. The mean intervertebral disc height was increased by 3.01 mm after the operation, but the mean height was 2.17 mm shorter at the last follow-up than after postoperation. In terms of clinical results, five Grade A cases and one Grade B case as assessed by the ASIA impairment scale were unchanged until the last follow-up. Twenty-three cases of Grade C, 16 cases of Grade D, and 13 cases of Grade E improved to seven cases, 26 cases, and 19 cases, respectively. Three

  12. Constraints from Seamounts on Pacific Plate or Plume Motion Prior to 80 Ma.

    Science.gov (United States)

    Konter, J. G.; Koppers, A. A. P.; Jackson, M. G.; Finlayson, V.; Konrad, K.

    2015-12-01

    The Hawaii-Emperor and Louisville hotspot tracks have long dominated the data set constraining absolute plate motion models. However, prior to ~80 Ma, multiple shorter, discontinuous hotspot trails and oceanic plateaus have been used to constrain absolute plate motion. Based on this earlier work, a clear Hawaii-Emperor style bend seems apparent around 100 Ma in the West Pacific Seamount Province (WPSP). More importantly, the ongoing debate on a plate versus plume motion origin for the Hawaii-Emperor Bend is applicable here, as the ~100 Ma bend may correspond to a global plate reorganization (Matthews et al., EPSL, 2012). Data for a comparison of bends comes from three groups with similar geographic patterns: 1) Mid-Pacific Mountains, Line Islands; 2) Shatsky Rise, Hess Rise, Musician and Wentworth Seamounts; and 3) Wake Seamounts, Marshall Islands, Magellan Seamounts. Both groups 1 and 2 feature a large igneous province (LIP) at their oldest end: Shatsky Rise and the Mid-Pacific Mountains. According to plate reconstructions these LIPs were constructed near all-ridge triple junctions, thus potential plume-ridge interactions need to be clarified before these LIPs can be used to define an absolute mantle reference frame. In contrast, the volcanoes of the third group (Wake, Marshall, Magellan) did erupt truly intra-plate and we therefore argue that this group provides a constraint on plate motion beyond 80 Ma that is independent of plume-ridge interactions. Since the volcanoes in this group are part of the WPSP, which is densely populated with seamounts, a combination of 40Ar/39Ar ages and Sr-Nd-Pb-Hf isotopes is needed to distinguish different hotspot tracks in this region. Backtracking each volcano through its age to its original eruptive location and using compositional color-coding, reveals groupings and patterns that vary by plate motion model, while the temporal patterns of backtracked locations inform us about potential plume motions.

  13. Interactive Assembly Guide using Augmented Reality

    DEFF Research Database (Denmark)

    Andersen, Martin; Andersen, Rasmus Skovgaard; Larsen, Christian Lindequist

    2009-01-01

    This paper presents an Augmented Reality system for aiding a pump assembling process at Grundfos, one of the leading pump producers. Stable pose estimation of the pump is required in order to augment the graphics correctly. This is achieved by matching image edges with synthesized edges from CAD...... norm. A dynamic visualization of the augmented graphics provides the user with guidance. Usability tests show that the accuracy of the system is sufficient for assembling the pump....

  14. External fixation using locking plate in distal tibial fracture: a finite element analysis.

    Science.gov (United States)

    Zhang, Jingwei; Ebraheim, Nabil; Li, Ming; He, Xianfeng; Schwind, Joshua; Liu, Jiayong; Zhu, Limei

    2015-08-01

    External fixation of tibial fractures using a locking plate has been reported with favorable results in some selected patients. However, the stability of external plate fixation in this fracture pattern has not been previously demonstrated. We investigated the stability of external plate fixation with different plate-bone distances. In this study, the computational processing model of external fixation of a distal tibial metaphyseal fracture utilizing the contralateral femoral less invasive stabilization system plate was analyzed. The plate was placed on the anteromedial aspect of tibia with different plate-bone distances: 1, 10, 20, and 30 mm. Under axial load, the stiffness of construct in all groups was higher than intact tibia. Under axial load with an internal rotational force, the stiffness of construct with 1 and 10 mm plate-bone distances was similar to that of an intact tibia and the stiffness of the construct with 20 and 30 mm distances was lower than that of an intact tibia. Under axial load with an external rotational force, the stiffness of the construct in all groups was lower than that of an intact tibia. The maximum plate stresses were concentrated at the two most distal screws and were highest in the construct with the 10 mm plate-bone distance, and least in the construct with a 1 mm plate-bone distance. To guarantee a stable external plate fixation in distal tibial fracture, the plate-bone distance should be less than 30 mm.

  15. Ligament augmentation for prevention of proximal junctional kyphosis and proximal junctional failure in adult spinal deformity.

    Science.gov (United States)

    Safaee, Michael M; Deviren, Vedat; Dalle Ore, Cecilia; Scheer, Justin K; Lau, Darryl; Osorio, Joseph A; Nicholls, Fred; Ames, Christopher P

    2018-05-01

    OBJECTIVE Proximal junctional kyphosis (PJK) is a well-recognized, yet incompletely defined, complication of adult spinal deformity surgery. There is no standardized definition for PJK, but most studies describe PJK as an increase in the proximal junctional angle (PJA) of greater than 10°-20°. Ligament augmentation is a novel strategy for PJK reduction that provides strength to the upper instrumented vertebra (UIV) and adjacent segments while also reducing junctional stress at those levels. METHODS In this study, ligament augmentation was used in a consecutive series of adult spinal deformity patients at a single institution. Patient demographics, including age; sex; indication for surgery; revision surgery; surgical approach; and use of 3-column osteotomies, vertebroplasty, or hook fixation at the UIV, were collected. The PJA was measured preoperatively and at last follow-up using 36-inch radiographs. Data on change in PJA and need for revision surgery were collected. Univariate and multivariate analyses were performed to identify factors associated with change in PJA and proximal junctional failure (PJF), defined as PJK requiring surgical correction. RESULTS A total of 200 consecutive patients were included: 100 patients before implementation of ligament augmentation and 100 patients after implementation of this technique. The mean age of the ligament augmentation cohort was 66 years, and 67% of patients were women. Over half of these cases (51%) were revision surgeries, with 38% involving a combined anterior or lateral and posterior approach. The mean change in PJA was 6° in the ligament augmentation group compared with 14° in the control group (p historical cohort, ligament augmentation is associated with a significant decrease in PJK and PJF. These data support the implementation of ligament augmentation in surgery for adult spinal deformity, particularly in patients with a high risk of developing PJK and PJF.

  16. Comparison of Absorbable Mesh Plate versus Titanium-Dynamic Mesh Plate in Reconstruction of Blow-Out Fracture: An Analysis of Long-Term Outcomes

    Directory of Open Access Journals (Sweden)

    Woon Il Baek

    2014-07-01

    Full Text Available Background A blow-out fracture is one of the most common facial injuries in midface trauma. Orbital wall reconstruction is extremely important because it can cause various functional and aesthetic sequelae. Although many materials are available, there are no uniformly accepted guidelines regarding material selection for orbital wall reconstruction. Methods From January 2007 to August 2012, a total of 78 patients with blow-out fractures were analyzed. 36 patients received absorbable mesh plates, and 42 patients received titanium-dynamic mesh plates. Both groups were retrospectively evaluated for therapeutic efficacy and safety according to the incidence of three different complications: enophthalmos, extraocular movement impairment, and diplopia. Results For all groups (inferior wall fracture group, medial wall fractrue group, and combined inferomedial wall fracture group, there were improvements in the incidence of each complication regardless of implant types. Moreover, a significant improvement of enophthalmos occurred for both types of implants in group 1 (inferior wall fracture group. However, we found no statistically significant differences of efficacy or complication rate in every groups between both implant types. Conclusions Both types of implants showed good results without significant differences in long-term follow up, even though we expected the higher recurrent enophthalmos rate in patients with absorbable plate. In conclusion, both types seem to be equally effective and safe for orbital wall reconstruction. In particular, both implant types significantly improve the incidence of enophthalmos in cases of inferior orbital wall fractures.

  17. Augmented reality for breast imaging.

    Science.gov (United States)

    Rancati, Alberto; Angrigiani, Claudio; Nava, Maurizio B; Catanuto, Giuseppe; Rocco, Nicola; Ventrice, Fernando; Dorr, Julio

    2018-02-21

    Augmented reality (AR) enables the superimposition of virtual reality reconstructions onto clinical images of a real patient, in real time. This allows visualization of internal structures through overlying tissues, thereby providing a virtual transparency vision of surgical anatomy. AR has been applied to neurosurgery, which utilizes a relatively fixed space, frames, and bony references; the application of AR facilitates the relationship between virtual and real data. Augmented Breast imaging (ABI) is described. Breast MRI studies for breast implant patients with seroma were performed using a Siemens 3T system with a body coil and a four-channel bilateral phased-array breast coil as the transmitter and receiver, respectively. The contrast agent used was (CA) gadolinium (Gd) injection (0.1 mmol/kg at 2 ml/s) by a programmable power injector. Dicom formated images data from 10 MRI cases of breast implant seroma and 10 MRI cases with T1-2 N0 M0 breast cancer, were imported and transformed into Augmented reality images. Augmented breast imaging (ABI) demonstrated stereoscopic depth perception, focal point convergence, 3D cursor use, and joystick fly-through. Augmented breast imaging (ABI) to the breast can improve clinical outcomes, giving an enhanced view of the structures to work on. It should be further studied to determine its utility in clinical practice.

  18. Vertical ridge augmentation using xenogenous bone blocks: a comparison between the flap and tunneling procedures.

    Science.gov (United States)

    Xuan, Feng; Lee, Chun-Ui; Son, Jeong-Seog; Fang, Yiqin; Jeong, Seung-Mi; Choi, Byung-Ho

    2014-09-01

    Previous studies have shown that the subperiosteal tunneling procedure in vertical ridge augmentation accelerates healing after grafting and prevents graft exposure, with minor postoperative complications. It is conceivable that new bone formation would be greater with the tunneling procedure than with the flap procedure, because the former is minimally invasive. This hypothesis was tested in this study by comparing new bone formation between the flap and tunneling procedures after vertical ridge augmentation using xenogenous bone blocks in a canine mandible model. Two Bio-Oss blocks were placed on the edentulous ridge in each side of the mandibles of 6 mongrel dogs. The blocks in each side were randomly assigned to grafting with a flap procedure (flap group) or grafting with a tunneling procedure (tunneling group). The mean percentage of newly formed bone within the block was 15.3 ± 6.6% in the flap group and 46.6 ± 23.4% in the tunneling group. Based on data presented in this study, when a tunneling procedure is used to place xenogenous bone blocks for vertical ridge augmentation, bone formation in the graft sites is significantly greater than when a flap procedure is used. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Aspects of User Experience in Augmented Reality

    DEFF Research Database (Denmark)

    Madsen, Jacob Boesen

    in human factors related to Augmented Reality. This is investigated partly as how Augmented Reality applications are used in unsupervised settings, and partly in specific evaluations related to user performance in supervised settings. The thesis starts by introducing Augmented Reality to the reader......, followed by a presentation of the technical areas related to the field, and different human factor areas. As a contribution to the research area, this thesis presents five separate, but sequential, papers within the area of Augmented Reality.......In Augmented Reality applications, the real environment is annotated or enhanced with computer-generated graphics. This is a topic that has been researched in the recent decades, but for many people this is a brand new and never heard of topic. The main focus of this thesis is investigations...

  20. ESELEM 4: a code for calculating fine neutron spectrum and multi-group cross sections in plate lattice

    International Nuclear Information System (INIS)

    Nakagawa, Masayuki; Katsuragi, Satoru; Narita, Hideo.

    1976-07-01

    The multi-group treatment has been used in the design study of fast reactors and analysis of experiments at fast critical assemblies. The accuracy of the multi-group cross sections therefore affects strongly the results of these analyses. The ESELEM 4 code has been developed to produce multi-group cross sections with an advanced method from the nuclear data libraries used in the JAERI Fast set. ESELEM 4 solves integral transport equation by the collision probability method in plate lattice geometry to obtain the fine neutron spectrum. A typical fine group mesh width is 0.008 in lethargy unit. The multi-group cross sections are calculated by weighting the point data with the fine structure neutron flux. Some devices are applied to reduce computation time and computer core storage required for the calculation. The slowing down sources are calculated with the use of a recurrence formula derived for elastic and inelastic scattering. The broad group treatment is adopted above 2 MeV for dealing with both light any heavy elements. Also the resonance cross sections of heavy elements are represented in a broad group structure, for which we use the values of the JAERI Fast set. The library data are prepared by the PRESM code from ENDF/A type nuclear data files. The cross section data can be compactly stored in the fast computer core memory for saving the core storage and data processing time. The programme uses the variable dimensions to increase its flexibility. The users' guide for ESELEM 4 and PRESM is also presented in this report. (auth.)

  1. An analytical study of the free and forced vibration response of a ribbed plate with free boundary conditions

    Science.gov (United States)

    Lin, Tian Ran; Zhang, Kai

    2018-05-01

    An analytical study to predict the vibration response of a ribbed plate with free boundary conditions is presented. The analytical solution was derived using a double cosine integral transform technique and then utilized to study the free and forced vibration of the ribbed plate, as well as the effect of the rib on the modal response of the uniform plate. It is shown that in addition to the three zero-frequency rigid body modes of the plate, the vibration modes of the uniform plate can be classified into four mode groups according to the symmetric properties of the plate with respect to the two orthogonal middle lines parallel to the plate edges. The four mode groups correspond to a double symmetric group, a double anti-symmetric group and two symmetric/anti-symmetric groups. Whilst the inclusion of the rib to the plate is shown to cause distortion to the distribution of vibration modes, most modes can still be traced back to the original modes of the uniform plate. Both the mass and stiffness of the rib are shown to affect the modal vibration of the uniform plate, whereby a dominant effect from the rib mass leads to a decrease in the modal frequency of the plate, whereas a dominant effect from the rib stiffness leads to an increase in plate modal frequency. When the stiffened rib behaves as an effective boundary to the plate vibration, an original plate mode becomes a pair of degenerate modes, whereby one mode has a higher frequency and the other mode has a lower frequency than that of the original mode.

  2. The HART I augmented electric gun facility

    International Nuclear Information System (INIS)

    Fikse, D.A.; Ciesar, J.A.; Wehrli, H.A.; Rimersma, H.; Docherty, E.F.; Pipich, C.W.

    1991-01-01

    This paper reports on an augmented electric gun system that has been commissioned. This system, called HART I (Hypervelocity Augmented Railgun Test), is built around a double augmented rail arrangement with a 1.27-cm square bore. It is powered by the SUVAC II 5.6-MJ distributed capacitor power supply. This arrangement allows operation in a simple, series augmented, or transaugmented gun system configuration. The objective of this facility is to perform materials research augmentation studies, and armature development in the 10-km/s regime. Armature masses of 2 to 4 g will be accelerated in a 4-m long barrel. Baseline bore materials will begin with conventional G9/GlidCop systems and then move into pyrolytic boron nitride/refractory materials. Hybrids, plasma, and ablation stabilized armature systems are planned. The gun system is instrumented with plasma and rail B probes for inbore velocity measurements. In addition, breech and muzzle voltages, currents, and external velocities are measured. The HART I system is currently performing hypervelocity experiments to verify the augmentation models

  3. Augmented “Ouch!”. : How to create intersubjective augmented objects into which we can bump

    NARCIS (Netherlands)

    Liberati, Nicola

    2015-01-01

    The aim of this work is to provide the elements to design an intersubjective augmented reality in order to make the augmented objects part of our everyday world. This work will analyse intersubjectivity from a phenomenological point of view using the works by Husserl and Schutz. Thanks to these two

  4. Breast Augmentation

    African Journals Online (AJOL)

    1974-04-13

    Apr 13, 1974 ... Complications encountered after breast augmentation are dealt with in .... in Phisohex or other suitable preparation for a few days before surgery ... In all cases, the prosthesis causes a fibrous tissue capsule to form around it.

  5. Create Your Plate

    Medline Plus

    Full Text Available ... Plate Share Create Your Plate ! Share: Seven Simple Steps to Create Your Plate It's simple and effective ... foods within each food category. Try these seven steps to get started: Using your dinner plate, put ...

  6. Marketing and Augmented Reality

    OpenAIRE

    Zelený, Martin

    2010-01-01

    The main goal of this diploma thesis is to identify the usage of augmented reality in contemporary marketing practice and the expectations of marketers for the future use. This will be achieved by conducting a quantitative and qualitative research among existing creative and advertising companies. Secondary goal is introducing the concept of augmented reality from the theoretical point of view and also description of potential utilization based on known examples. The tools for the practical p...

  7. Augmented reality and its practical application

    OpenAIRE

    ZÍTKOVÁ, Helena

    2011-01-01

    This thesis combines topic of augmented reality with tourism. For analyzing the state of the use of augmented reality was composed case studies. It was created product, which is called Guide to mobile phone.

  8. Augmented Fotonovelas: A Visual Methodology for Community Engaged Research

    OpenAIRE

    Hidalgo, LeighAnna Grace

    2014-01-01

    Augmented Fotonovelas draw upon the aesthetic of traditional fotonovelas, but incorporate new technologies--such as video interviews, interactive mapping, smart phone technology, and Augmented Reality (AR). Augmented Fotonovelas also make the most of the classic form, utilizing photographs, text, and bubble captions. Through this methodology, new and old come together to produce Augmented Scholarship. I define Augmented Scholarship as knowledge production bridging the gap between communities ...

  9. New education system for construction of optical holography setup – Tangible learning with Augmented Reality

    International Nuclear Information System (INIS)

    Yamaguchi, Takeshi; Yoshikawa, Hiroshi

    2013-01-01

    In case of teaching optical system construction, it is difficult to prepare the optical components for the attendance student. However the tangible learning is very important to master the optical system construction. It helps learners understand easily to use an inexpensive learning system that provides optical experiments experiences. Therefore, we propose the new education system for construction of optical setup with the augmented reality. To use the augmented reality, the proposed system can simulate the optical system construction by the direct hand control. Also, this system only requires an inexpensive web camera, printed makers and a personal computer. Since this system does not require the darkroom and the expensive optical equipments, the learners can study anytime, anywhere when they want to do. In this paper, we developed the system that can teach the optical system construction of the Denisyuk hologram and 2-step transmission type hologram. For the tangible learning and the easy understanding, the proposed system displays the CG objects of the optical components on the markers which are controlled by the learner's hands. The proposed system does not only display the CG object, but also display the light beam which is controlled by the optical components. To display the light beam that is hard to be seen directly, the learners can confirm about what is happening by the own manipulation. For the construction of optical holography setup, we arrange a laser, mirrors, a PBS (polarizing beam splitter), lenses, a polarizer, half-wave plates, spatial filters, an optical power meter and a recording plate. After the construction, proposed system can check optical setup correctly. In comparison with the learners who only read a book, the learners who use the system can construct the optical holography setup more quickly and correctly.

  10. Augmenting the Web through Open Hypermedia

    DEFF Research Database (Denmark)

    Bouvin, N.O.

    2003-01-01

    Based on an overview of Web augmentation and detailing the three basic approaches to extend the hypermedia functionality of the Web, the author presents a general open hypermedia framework (the Arakne framework) to augment the Web. The aim is to provide users with the ability to link, annotate, a......, and otherwise structure Web pages, as they see fit. The paper further discusses the possibilities of the concept through the description of various experiments performed with an implementation of the framework, the Arakne Environment......Based on an overview of Web augmentation and detailing the three basic approaches to extend the hypermedia functionality of the Web, the author presents a general open hypermedia framework (the Arakne framework) to augment the Web. The aim is to provide users with the ability to link, annotate...

  11. Muzzle shunt augmentation of conventional railguns

    International Nuclear Information System (INIS)

    Parker, J.V.

    1991-01-01

    This paper reports on augmentation which is a technique for reducing the armature current and hence the armature power dissipation in a plasma armature railgun. In spite of the advantages, no large augmented railguns have been built, primarily due to the mechanical and electrical complexity introduced by the extra conductors required. it is possible to achieve some of the benefits of augmentation in a conventional railgun by diverting a fraction φ of the input current through a shunt path at the muzzle of the railgun. In particular, the relation between force and armature current is the same as that obtained in an n-turn, series-connected augmented railgun with n = 1/(1 - φ). The price of this simplification is a reduction in electrical efficiency and some additional complexity in the external electrical system

  12. Distance learning ects and flipped classroom in the anatomy learning: comparative study of the use of augmented reality, video and notes.

    Science.gov (United States)

    Ferrer-Torregrosa, Javier; Jiménez-Rodríguez, Miguel Ángel; Torralba-Estelles, Javier; Garzón-Farinós, Fernanda; Pérez-Bermejo, Marcelo; Fernández-Ehrling, Nadia

    2016-09-01

    The establishment of the ECTS (European Credit Transfer System) is one of the pillars of the European Space of Higher Education. This way of accounting for the time spent in training has two essential parts, classroom teaching (work with the professor) and distance learning (work without the professor, whether in an individual or collective way). Much has been published on the distance learning part, but less on the classroom teaching section. In this work, the authors investigate didactic strategies and associated aids for distance learning work in a concept based on flipped classroom where transmitting information is carried out with aids that the professor prepares, so that the student works in an independent way before the classes, thus being able to dedicate the classroom teaching time to more complex learning and being able to count on the professor's help. Three teaching aids applied to the study of anatomy have been compared: Notes with images, videos, and augmented reality. Four dimensions have been compared: the time spent, the acquired learnings, the metacognitive perception, and the prospects of the use of augmented reality for study. The results show the effectiveness, in all aspects, of augmented reality when compared with the rest of aids. The questionnaire assessed the acquired knowledge through a course exam, where 5.60 points were obtained for the notes group, 6.54 for the video group, and 7.19 for the augmented reality group. That is 0.94 more points for the video group compared with the notes and 1.59 more points for the augmented reality group compared with the notes group. This research demonstrates that, although technology has not been sufficiently developed for education, it is expected that it can be improved in both the autonomous work of the student and the academic training of health science students and that we can teach how to learn. Moreover, one can see how the grades of the students who studied with augmented reality are more

  13. Aplikasi Web Augmented Reality Villa

    Directory of Open Access Journals (Sweden)

    Gede Yudha Prema Pangestu

    2017-07-01

    Full Text Available Bali is one of the highly developed tourist destination in Indonesia. The arrival of tourists having holiday in Bali led to increase residential needs with complete amenities. The occupancy rate of hotel and villa in Bali is increase significantlly during the long vacation. The emergence of new villa and hotel occupancy raises the level of competition in business, so it needs a correct use good marketing communication strategy in marketing the product in order to attract the attention of consumers. Web Application Augmented Reality Villa can help visualize the residential villa in three-dimensional shapes that look more attractive and practical. The use of brochures as written information and the application of augmented reality technology on the Web Application Augmented Reality Villa aims to develop an application that can provide information about the villa to visitors. Web Application uses Augmented Reality Villa designed by FlarToolkit library. Based on the test results show the application can display 3-dimensional objects by scanning marker villa in a brochure which already contain marker.

  14. Casimir energy between two parallel plates and projective representation of the Poincaré group

    Science.gov (United States)

    Akita, Takamaru; Matsunaga, Mamoru

    2016-06-01

    The Casimir effect is a physical manifestation of zero point energy of quantum vacuum. In a relativistic quantum field theory, Poincaré symmetry of the theory seems, at first sight, to imply that nonzero vacuum energy is inconsistent with translational invariance of the vacuum. In the setting of two uniform boundary plates at rest, quantum fields outside the plates have (1 +2 )-dimensional Poincaré symmetry. Taking a massless scalar field as an example, we have examined the consistency between the Poincaré symmetry and the existence of the vacuum energy. We note that, in quantum theory, symmetries are represented projectively in general and show that the Casimir energy is connected to central charges appearing in the algebra of generators in the projective representations.

  15. Augmented Reality Comes to Physics

    Science.gov (United States)

    Buesing, Mark; Cook, Michael

    2013-01-01

    Augmented reality (AR) is a technology used on computing devices where processor-generated graphics are rendered over real objects to enhance the sensory experience in real time. In other words, what you are really seeing is augmented by the computer. Many AR games already exist for systems such as Kinect and Nintendo 3DS and mobile apps, such as…

  16. Immobilization of mesoporous silica particles on stainless steel plates

    International Nuclear Information System (INIS)

    Pasqua, Luigi; Morra, Marco

    2017-01-01

    A preliminary study aimed to the nano-engineering of stainless steel surface is presented. Aminopropyl-functionalized mesoporous silica is covalently and electrostatically anchored on the surface of stainless steel plates. The anchoring is carried out through the use of a nanometric spacer, and two different spacers are proposed (both below 2 nm in size). The first sample is obtained by anchoring to the stainless steel amino functionalized, a glutaryl dichloride spacer. This specie forms an amide linkage with the amino group while the unreacted acyl groups undergo hydrolysis giving a free carboxylic group. The so-obtained functionalized stainless steel plate is used as substrate for anchoring derivatized mesoporous silica particles. The second sample is prepared using 2-bromo-methyl propionic acid as spacer (BMPA). Successively, the carboxylic group of propionic acid is condensed to the aminopropyl derivatization on the external surface of the mesoporous silica particle through covalent bond. In both cases, a continuous deposition (coating thickness is around 10 μm) is obtained, in fact, XPS data do not reveal the metal elements constituting the plate. The nano-engineering of metal surfaces can represent an intriguing opportunity for producing long-term drug release or biomimetic surface.

  17. Immobilization of mesoporous silica particles on stainless steel plates

    Energy Technology Data Exchange (ETDEWEB)

    Pasqua, Luigi, E-mail: luigi.pasqua@unical.it [University of Calabria, Department of Environmental and Chemical Engineering (Italy); Morra, Marco, E-mail: mmorra@nobilbio.com [Via Valcastellana 26 (Italy)

    2017-03-15

    A preliminary study aimed to the nano-engineering of stainless steel surface is presented. Aminopropyl-functionalized mesoporous silica is covalently and electrostatically anchored on the surface of stainless steel plates. The anchoring is carried out through the use of a nanometric spacer, and two different spacers are proposed (both below 2 nm in size). The first sample is obtained by anchoring to the stainless steel amino functionalized, a glutaryl dichloride spacer. This specie forms an amide linkage with the amino group while the unreacted acyl groups undergo hydrolysis giving a free carboxylic group. The so-obtained functionalized stainless steel plate is used as substrate for anchoring derivatized mesoporous silica particles. The second sample is prepared using 2-bromo-methyl propionic acid as spacer (BMPA). Successively, the carboxylic group of propionic acid is condensed to the aminopropyl derivatization on the external surface of the mesoporous silica particle through covalent bond. In both cases, a continuous deposition (coating thickness is around 10 μm) is obtained, in fact, XPS data do not reveal the metal elements constituting the plate. The nano-engineering of metal surfaces can represent an intriguing opportunity for producing long-term drug release or biomimetic surface.

  18. Comparison of Broström technique, suture anchor repair, and tape augmentation for reconstruction of the anterior talofibular ligament.

    Science.gov (United States)

    Schuh, R; Benca, E; Willegger, M; Hirtler, L; Zandieh, S; Holinka, J; Windhager, R

    2016-04-01

    Recently, tape augmentation for Broström repair has been introduced in order to improve the primary stability of the reconstructed anterior talofibular ligament (ATFL). The biomechanical effect of tape augmentation suture anchor (SA) repair is not known yet. The aim of the present study was to compare construct stability of the traditional Broström (TB) repair compared with a stand alone SA repair (SutureTak, Arthrex) and SA repair combined with tape augmentation (InternalBrace, Arthrex) internal brace (IB) of the ATFL. Eighteen fresh-frozen human anatomic lower leg specimens were randomly assigned to three different groups: TB group, SA group, and IB augmentation group. In vivo torsion conditions in ankle sprain were carried out quasi-statically (0.5°/s). Torque (Nm) required to resist as well as the rotary displacement (°) of the load frame was recorded. Intergroup differences for age, bone mineral density (BMD), angle at failure, and torque at failure were analysed using ANOVA. In the TB group, ATFL reconstruction failed at an angle of 24.1°, in the SA group failure occurred at 35.5°, and in the IB group it failed at 46.9° (p = 0.02). Torque at failure reached 5.7 Nm for the TB repair, 8.0 Nm for the SA repair, and 11.2 Nm for the IB group (p = 0.04). There was no correlation between angle at ATFL failure, torque at failure, and BMD for the SA or IB groups. The present biomechanical study reveals statistically superior performance in terms of angle at failure as well as failure torque for the IB group compared to the other reconstruction methods. BMD did not influence the construct stability in the SA repair groups.

  19. Augmented Versus Nonaugmented Repair of Acute Achilles Tendon Rupture: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Zhang, Yi-Jun; Zhang, Chi; Wang, Quan; Lin, Xiang-Jin

    2017-04-01

    Although simple end-to-end repair of the Achilles tendon is common, many augmented repair protocols have been implemented for acute Achilles tendon rupture. However, whether augmented repair is better than nonaugmented repair of an acute Achilles tendon rupture is still unknown. To conduct a meta-analysis to determine whether augmented surgical repair of an acute Achilles tendon rupture improved subjective patient satisfaction without an increase in rerupture rates. Secondary outcomes assessed included infections, ankle range of motion, calf muscle strength, and minor complications. Meta-analysis. A systematic literature search of peer-reviewed articles was conducted to identify all randomized controlled trials (RCTs) comparing augmented repair and nonaugmented repair for acute Achilles tendon rupture from January 1980 to August 2016 in the electronic databases of PubMed, Web of Science (SCI-E/SSCI/A&HCI), and EMBASE. The keywords (Achilles tendon rupture) AND (surg* OR operat* OR repair* OR augment* OR non-augment* OR end-to-end OR sutur*) were combined, and results were limited to human RCTs and controlled clinical trials published in the English language. Four RCTs involving 169 participants were eligible for inclusion; 83 participants were treated with augmented repair and 86 were treated with nonaugmented repair. Augmented repair led to similar responses when compared with nonaugmented repair for acute Achilles tendon rupture (93% vs 90%, respectively; P = .53). The rerupture rates showed no significant difference for augmented versus nonaugmented repair (7.2% vs 9.3%, respectively; P = .69). No differences in superficial and deep infections occurred in augmented (7 infections) and nonaugmented (8 infections) repair groups during postoperative follow-up ( P = .89). The average incisional infection rate was 8.4% with augmented repair and 9.3% with nonaugmented repair. No significant differences in other complications were found between augmented (7.2%) and

  20. Imaging features of ductal plate malformations in adults

    Energy Technology Data Exchange (ETDEWEB)

    Venkatanarasimha, N., E-mail: nandashettykv@yahoo.com [Department of Radiology, Derriford Hospital, Plymouth (United Kingdom); Thomas, R.; Armstrong, E.M.; Shirley, J.F.; Fox, B.M.; Jackson, S.A. [Department of Radiology, Derriford Hospital, Plymouth (United Kingdom)

    2011-11-15

    Ductal plate malformations, also known as fibrocystic liver diseases, are a group of congenital disorders resulting from abnormal embryogenesis of the biliary ductal system. The abnormalities include choledochal cyst, Caroli's disease and Caroli's syndrome, adult autosomal dominant polycystic liver disease, and biliary hamartoma. The hepatic lesions can be associated with renal anomalies such as autosomal recessive polycystic kidney disease (ARPKD), medullary sponge kidney, and nephronophthisis. A clear knowledge of the embryology and pathogenesis of the ductal plate is central to the understanding of the characteristic imaging appearances of these complex disorders. Accurate diagnosis of ductal plate malformations is important to direct appropriate clinical management and prevent misdiagnosis.

  1. Comparison of the Pullout Strength of Different Pedicle Screw Designs and Augmentation Techniques in an Osteoporotic Bone Model.

    Science.gov (United States)

    Kiyak, Gorkem; Balikci, Tevfik; Heydar, Ahmed Majid; Bezer, Murat

    2018-02-01

    Mechanical study. To compare the pullout strength of different screw designs and augmentation techniques in an osteoporotic bone model. Adequate bone screw pullout strength is a common problem among osteoporotic patients. Various screw designs and augmentation techniques have been developed to improve the biomechanical characteristics of the bone-screw interface. Polyurethane blocks were used to mimic human osteoporotic cancellous bone, and six different screw designs were tested. Five standard and expandable screws without augmentation, eight expandable screws with polymethylmethacrylate (PMMA) or calcium phosphate augmentation, and distal cannulated screws with PMMA and calcium phosphate augmentation were tested. Mechanical tests were performed on 10 unused new screws of each group. Screws with or without augmentation were inserted in a block that was held in a fixture frame, and a longitudinal extraction force was applied to the screw head at a loading rate of 5 mm/min. Maximum load was recorded in a load displacement curve. The peak pullout force of all tested screws with or without augmentation was significantly greater than that of the standard pedicle screw. The greatest pullout force was observed with 40-mm expandable pedicle screws with four fins and PMMA augmentation. Augmented distal cannulated screws did not have a greater peak pullout force than nonaugmented expandable screws. PMMA augmentation provided a greater peak pullout force than calcium phosphate augmentation. Expandable pedicle screws had greater peak pullout forces than standard pedicle screws and had the advantage of augmentation with either PMMA or calcium phosphate cement. Although calcium phosphate cement is biodegradable, osteoconductive, and nonexothermic, PMMA provided a significantly greater peak pullout force. PMMA-augmented expandable 40-mm four-fin pedicle screws had the greatest peak pullout force.

  2. Augmented reality implementation methods in mainstream applications

    Directory of Open Access Journals (Sweden)

    David Procházka

    2011-01-01

    Full Text Available Augmented reality has became an useful tool in many areas from space exploration to military applications. Although used theoretical principles are well known for almost a decade, the augmented reality is almost exclusively used in high budget solutions with a special hardware. However, in last few years we could see rising popularity of many projects focused on deployment of the augmented reality on dif­ferent mobile devices. Our article is aimed on developers who consider development of an augmented reality application for the mainstream market. Such developers will be forced to keep the application price, therefore also the development price, at reasonable level. Usage of existing image processing software library could bring a significant cut-down of the development costs. In the theoretical part of the article is presented an overview of the augmented reality application structure. Further, an approach for selection appropriate library as well as the review of the existing software libraries focused in this area is described. The last part of the article out­lines our implementation of key parts of the augmented reality application using the OpenCV library.

  3. Paper microzone plates.

    Science.gov (United States)

    Carrilho, Emanuel; Phillips, Scott T; Vella, Sarah J; Martinez, Andres W; Whitesides, George M

    2009-08-01

    This paper describes 96- and 384-microzone plates fabricated in paper as alternatives to conventional multiwell plates fabricated in molded polymers. Paper-based plates are functionally related to plastic well plates, but they offer new capabilities. For example, paper-microzone plates are thin (approximately 180 microm), require small volumes of sample (5 microL per zone), and can be manufactured from inexpensive materials ($0.05 per plate). The paper-based plates are fabricated by patterning sheets of paper, using photolithography, into hydrophilic zones surrounded by hydrophobic polymeric barriers. This photolithography used an inexpensive formulation photoresist that allows rapid (approximately 15 min) prototyping of paper-based plates. These plates are compatible with conventional microplate readers for quantitative absorbance and fluorescence measurements. The limit of detection per zone loaded for fluorescence was 125 fmol for fluorescein isothiocyanate-labeled bovine serum albumin, and this level corresponds to 0.02 the quantity of analyte per well used to achieve comparable signal-to-noise in a 96-well plastic plate (using a solution of 25 nM labeled protein). The limits of detection for absorbance on paper was approximately 50 pmol per zone for both Coomassie Brilliant Blue and Amaranth dyes; these values were 0.4 that required for the plastic plate. Demonstration of quantitative colorimetric correlations using a scanner or camera to image the zones and to measure the intensity of color, makes it possible to conduct assays without a microplate reader.

  4. First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

    Directory of Open Access Journals (Sweden)

    Leif Claassen

    2017-07-01

    Full Text Available Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis with crossed-screwsor with a nonlocking plate with lag screw. Results: There were four non-unions in crossed-screws patients and one nonunion in non-locked plate group. All the patients in locking plate group achieved union. 90% of the patients were completely or mildly satisfied in locking plate group, whereas this rate was 80% for patients in both crossed screws and non-locking plate groups. Conclusions: Use of dorsal plating for arthrodesis of MTP1 joint either locking or non-locking were associated with high union rate and acceptable and comparable functional outcome. Although nonunion rate was high using two crossed screws but functional outcome was not significantly different compare to dorsal plating. Level of evidence:Ш, retrospective comparative study

  5. Augmentation of Distal Biceps Repair With an Acellular Dermal Graft Restores Native Biomechanical Properties in a Tendon-Deficient Model.

    Science.gov (United States)

    Conroy, Christine; Sethi, Paul; Macken, Craig; Wei, David; Kowalsky, Marc; Mirzayan, Raffy; Pauzenberger, Leo; Dyrna, Felix; Obopilwe, Elifho; Mazzocca, Augustus D

    2017-07-01

    The majority of distal biceps tendon injuries can be repaired in a single procedure. In contrast, complete chronic tears with severe tendon substance deficiency and retraction often require tendon graft augmentation. In cases with extensive partial tears of the distal biceps, a human dermal allograft may be used as an alternative to restore tendon thickness and biomechanical integrity. Dermal graft augmentation will improve load to failure compared with nonaugmented repair in a tendon-deficient model. Controlled laboratory study. Thirty-six matched specimens were organized into 1 of 4 groups: native tendon, native tendon with dermal graft augmentation, tendon with an attritional defect, and tendon with an attritional defect repaired with a graft. To mimic a chronic attritional biceps lesion, a defect was created by a complete tear, leaving 30% of the tendon's width intact. The repair technique in all groups consisted of cortical button and interference screw fixation. All specimens underwent cyclical loading for 3000 cycles and were then tested to failure; gap formation and peak load at failure were documented. The mean (±SD) load to failure (320.9 ± 49.1 N vs 348.8 ± 77.6 N, respectively; P = .38) and gap formation (displacement) (1.8 ± 1.4 mm vs 1.6 ± 1.1 mm, respectively; P = .38) did not differ between the native tendon groups with and without graft augmentation. In the tendon-deficient model, the mean load to failure was significantly improved with graft augmentation compared with no graft augmentation (282.1 ± 83.8 N vs 199.7 ± 45.5 N, respectively; P = .04), while the mean gap formation was significantly reduced (1.2 ± 1.0 mm vs 2.7 ± 1.4 mm, respectively; P = .04). The mean load to failure of the deficient tendon with graft augmentation (282.1 N) compared with the native tendon (348.8 N) was not significantly different ( P = .12). This indicates that the native tendon did not perform differently from the grafted deficient tendon. In a tendon

  6. Augmented reality som wearable

    DEFF Research Database (Denmark)

    Buhl, Mie; Rahn, Annette

    2015-01-01

    Artiklen omhandler design og implementering af Augmented Reality (AR) i form af en wearable i sygeplejerskeuddannelsens anatomiundervisning, mere specifikt undervisning i lungeanatomi og respiration, med fokus på potentialer for visuel læring. Projektet undersøger, hvordan en udviklet AR-applikat......Artiklen omhandler design og implementering af Augmented Reality (AR) i form af en wearable i sygeplejerskeuddannelsens anatomiundervisning, mere specifikt undervisning i lungeanatomi og respiration, med fokus på potentialer for visuel læring. Projektet undersøger, hvordan en udviklet AR...

  7. AUGMENTED REALITY - STATE OF KNOWLEDGE, USE AND EXPERIMENTATION

    Directory of Open Access Journals (Sweden)

    Mihaela Filofteia TUTUNEA

    2013-12-01

    Full Text Available Technologies for augmenting reality have been consolidated during the last decades, extending their applicability to more and more socio-economic areas. The rapid evolution of mobile technologies and virtualization of the digital environment have created auspicious conditions for massive extension and implementation of solutions for augmenting reality at global level. Experience has already shown that augmented reality, alongside virtual reality can offer very important support solutions in modeling the real world with the aim of extending the human capabilities of perception, allowing the opening of a new phase in the world’s socio-economic development. Starting from the evident tendencies that have manifested at global level in the development and implementation of augmented reality technologies, the paper begins with the presentation of the most important aspects related to augmented reality technologies, highlighting their main areas of application, and presents the study realized for identifying the level of knowledge, use and effective experimentation of augmented reality applications by mobile device users. The results of this study could be very useful to the socio-economic environment, starting with the field of research, continuing with developers and providers of augmented reality solutions, manufacturers and providers of hardware infrastructure support for augmented reality solutions and systems, final users of these solutions, both individuals and businesses, and experimenting digital communities.

  8. Advances in bone augmentation to enable dental implant placement: Consensus Report of the Sixth European Workshop on Periodontology.

    Science.gov (United States)

    Tonetti, Maurizio S; Hämmerle, Christoph H F

    2008-09-01

    Bone augmentation procedures to enable dental implant placement are frequently performed in practice. In this session the European Workshop on Periodontology discussed the evidence in support of the procedures and examined both adverse events and implant performance in the augmented bone. While the available evidence improved both in quantity and quality since previous workshops the conclusions that could be drawn were limited by elements of design and/or reporting that are amenable to improvement. With regards to lateral bone augmentation, a sizable body of evidence supports its use to enable dental implant placement. The group recognized the potential for vertical ridge augmentation procedures to allow implant placement in clinical practice but questioned the applicability of these data to a wider array of operators and clinical settings. With regards to sinus floor augmentation, perforation of the sinus membrane, graft infection and graft loss resulting in inability of implant placement were the major reported adverse events. In cases with dental implants placed in pristine sites. The consensus emphasized the research need to answer questions on: (i) long-term performance of dental implants placed in augmented bone; (ii) the clinical performance of dental implants placed in augmented or pristine sites; and (iii) the clinical benefits of bone augmentation with respect to alternative treatments.

  9. Modified T-Plate Interpositional Arthroplasty for Temporomandibular Joint Ankylosis: A New and Versatile Option

    Directory of Open Access Journals (Sweden)

    Imran Ahmad

    2015-11-01

    Full Text Available BackgroundThis study has been conducted with the aim of evaluating modified T-plate interpositional arthroplasty.MethodsA prospective comparative study in patients admitted with temporomandibular joint ankylosis. Ankylotic temporomandibular joint arthroplasty included condylectomy gap arthroplasty in 7, temporalis muscle flap interpositional arthroplasty in 8, and modified T-plate interpositional arthroplasty in 13 cases. The patients were followed for three years. Collected data were tabulated and subjected to Fisher's exact test, chi-square test and probability estimation.ResultsA significant increase in interincisal distance of 32 mm was seen in 12 (92.31% patients in the T-plate interposition group, in 2 (25% cases of the temporalis muscle flap interposition group, and in 1 case (14.28% of the condylectomy group at 12, 24, and 36 months. Re-ankylosis was observed in 1 case (9.69% of the T-plate interposition group, while as it was observed in 4 (50% cases in the temporalis muscle flap interposition group and 4 (57.14% cases in the condylectomy group, and these differences were statistically significant.ConclusionsOur clinical experience with the use of the T-plate over the past 5 years has been encouraging, and our physiotherapy technique is quite simple. Even illiterate parents can assess it easily. Hence, we recommend this easy technique that does not damage the temporalis muscle for the management of temporomandibular joint ankylosis.

  10. Empirical evaluation of augmented prototyping effectiveness

    Directory of Open Access Journals (Sweden)

    Tomáš Koubek

    2012-01-01

    Full Text Available Augmented reality is a scientific field well known for more than twenty years. Although there is a huge number of projects that present promising results, the real usage of augmented reality applications for fulfilling common tasks is almost negligible. We believe that one of the principal reasons is insufficient usability of these applications. The situation is analogous to the desktop, mobile or cloud application development or even to the web pages design. The first phase of a technology adoption is the exploration of its potential. As soon as the technical problems are overcome and the technology is widely accepted, the usability is a principal issue. The usability is utmost important also from the business point of view. The cost of augmented reality implementation into the production process is substantial, therefore, the usability that is directly responsible for the implemented solution effectiveness must be appropriately tested. Consequently, the benefit of the implemented solution can be measured.This article briefly outlines common techniques used for usability evaluation. Discussed techniques were designed especially for evaluation of desktop applications, mobile solutions and web pages. In spite of this drawback, their application on augmented reality products is usually possible. Further, a review of existing augmented reality project evaluations is presented.Based on this review, a usability evaluation method for our augmented prototyping application is proposed. This method must overcome the fact that the design is a creative process. Therefore, it is not possible to take into account common criteria such as time consumption.

  11. Augmented reality in dentistry: a current perspective.

    Science.gov (United States)

    Kwon, Ho-Beom; Park, Young-Seok; Han, Jung-Suk

    2018-02-21

    Augmentation reality technology offers virtual information in addition to that of the real environment and thus opens new possibilities in various fields. The medical applications of augmentation reality are generally concentrated on surgery types, including neurosurgery, laparoscopic surgery and plastic surgery. Augmentation reality technology is also widely used in medical education and training. In dentistry, oral and maxillofacial surgery is the primary area of use, where dental implant placement and orthognathic surgery are the most frequent applications. Recent technological advancements are enabling new applications of restorative dentistry, orthodontics and endodontics. This review briefly summarizes the history, definitions, features, and components of augmented reality technology and discusses its applications and future perspectives in dentistry.

  12. Augmented reality in a tumor resection model.

    Science.gov (United States)

    Chauvet, Pauline; Collins, Toby; Debize, Clement; Novais-Gameiro, Lorraine; Pereira, Bruno; Bartoli, Adrien; Canis, Michel; Bourdel, Nicolas

    2018-03-01

    Augmented Reality (AR) guidance is a technology that allows a surgeon to see sub-surface structures, by overlaying pre-operative imaging data on a live laparoscopic video. Our objectives were to evaluate a state-of-the-art AR guidance system in a tumor surgical resection model, comparing the accuracy of the resection with and without the system. Our system has three phases. Phase 1: using the MRI images, the kidney's and pseudotumor's surfaces are segmented to construct a 3D model. Phase 2: the intra-operative 3D model of the kidney is computed. Phase 3: the pre-operative and intra-operative models are registered, and the laparoscopic view is augmented with the pre-operative data. We performed a prospective experimental study on ex vivo porcine kidneys. Alginate was injected into the parenchyma to create pseudotumors measuring 4-10 mm. The kidneys were then analyzed by MRI. Next, the kidneys were placed into pelvictrainers, and the pseudotumors were laparoscopically resected. The AR guidance system allows the surgeon to see tumors and margins using classical laparoscopic instruments, and a classical screen. The resection margins were measured microscopically to evaluate the accuracy of resection. Ninety tumors were segmented: 28 were used to optimize the AR software, and 62 were used to randomly compare surgical resection: 29 tumors were resected using AR and 33 without AR. The analysis of our pathological results showed 4 failures (tumor with positive margins) (13.8%) in the AR group, and 10 (30.3%) in the Non-AR group. There was no complete miss in the AR group, while there were 4 complete misses in the non-AR group. In total, 14 (42.4%) tumors were completely missed or had a positive margin in the non-AR group. Our AR system enhances the accuracy of surgical resection, particularly for small tumors. Crucial information such as resection margins and vascularization could also be displayed.

  13. Augmented Reality

    DEFF Research Database (Denmark)

    Nielsen, Birgitte Lund; Brandt, Harald; Radmer, Ole

    2017-01-01

    Artiklen præsenterer resultater fra pilotafprøvning i 7.-klasses fysik/kemi og biologi af to Augmented Reality (AR)-apps til naturfagsundervisning. Muligheder og udfordringer ved lærerens stilladsering af elevernes undersøgende samtale og modelleringskompetence er undersøgt med interview...

  14. Augmentation of the Nasal Dorsum Using the Multistrip Autologous Cartilage Technique.

    Science.gov (United States)

    Liu, Liqiang; Bu, Zhaoyun; Fan, Jincai; Tian, Jia; Gan, Cheng; Yang, Zengjie; Jiao, Hu

    2017-12-01

    Nasal augmentation is a popular modern technique requested by many Asian people. There are two kinds of autologous cartilage used to augment the nose at present: carved as a monobloc or diced into pieces. Each approach has its pros and cons. The authors performed their surgical technique on a group of 28 patients. Twenty of these patients had undergone rhinoplasties performed before referral to our hospital; eight of these patients had undergone a primary rhinoplasty. Bilateral conchal, nasal septum, or rib cartilage was harvested; deep temporal fascia or abdominal muscle fascia to be prepared for packing stripped cartilage was also removed at this time. The cartilage was placed on a plastic cutting board and cut into strips with a transverse section of 1 × 1 mm. Then, these strips were packed and covered by fascia to form the grafts. The median follow-up was 23 months (range, 12 to 48 months). Twenty-two patients were satisfied with their augmented noses. Through examinations, biopsies, and magnetic resonance imaging scans, less resorption was observed with the multistrip autologous cartilage technique. Junctional stepoffs, excessive prominence, and slanting grafts occurred in three patients, two of whom had revisions. Using multistrip autologous cartilage grafts is an easier method to perform and could be another alternative technique for augmentative and reconstructive rhinoplasties.

  15. Locking screw-plate interface stability in carbon-fibre reinforced polyetheretherketone proximal humerus plates.

    Science.gov (United States)

    Hak, David J; Fader, Ryan; Baldini, Todd; Chadayammuri, Vivek B S

    2017-09-01

    Carbon-fibre reinforced polyetheretherketone (CFR-PEEK) plates have recently been introduced for proximal humerus fracture treatment. The purpose of this study was to compare the locking screw-plate interface stability in CFR-PEEK versus stainless steel (SS) proximal humerus plates. Locking screw mechanical stability was evaluated independently in proximal and shaft plate holes. Stiffness and load to failure were tested for three conditions: (1) on-axis locking screw insertion in CFR-PEEK versus SS plates, (2) on-axis locking screw insertion, removal, and reinsertion in CFR-PEEK plates, and (3) 10-degree off-axis locking screw insertion in CFR-PEEK plates. Cantilever bending at a rate of 1 mm/minute was produced by an Instron machine and load-displacement data recorded. Shaft locking screw load to failure was significantly greater in CFR-PEEK plates compared to SS plates (746.4 ± 89.7 N versus 596.5 ± 32.6 N, p PEEK plates (p PEEK plates. The mechanical stability of locking screws in CFR-PEEK plates is comparable or superior to locking screws in SS plates.

  16. Voltage-current characteristics of a pin-plate system with different plate configurations

    International Nuclear Information System (INIS)

    Feng, Zhuangbo; Long, Zhengwei

    2013-01-01

    In this paper, the voltage-current (V-I) characteristics of a pin-plate system with four types of collection plate configurations are studied experimentally. The collection plates consider a single metal plate, a metal plate with a fly ash cake layer, a metal plate with a clean filter media and a metal plate with a dirty filter media. The results show that the clean filter media has no obvious effect on the V-I characteristics. But the dirty filter media reduces the current density because of its high resistance. The thick fly ash cake layer increase current density because of the anti-corona effect but the increment is not very obvious.

  17. Augmented Reality Tower Technology Assessment

    Science.gov (United States)

    Reisman, Ronald J.; Brown, David M.

    2009-01-01

    Augmented Reality technology may help improve Air Traffic Control Tower efficiency and safety during low-visibility conditions. This paper presents the assessments of five off-duty controllers who shadow-controlled' with an augmented reality prototype in their own facility. Initial studies indicated unanimous agreement that this technology is potentially beneficial, though the prototype used in the study was not adequate for operational use. Some controllers agreed that augmented reality technology improved situational awareness, had potential to benefit clearance, control, and coordination tasks and duties and could be very useful for acquiring aircraft and weather information, particularly aircraft location, heading, and identification. The strongest objections to the prototype used in this study were directed at aircraft registration errors, unacceptable optical transparency, insufficient display performance in sunlight, inadequate representation of the static environment and insufficient symbology.

  18. Therapeutic options for lip augmentation.

    Science.gov (United States)

    Segall, Lorne; Ellis, David A F

    2007-11-01

    Aesthetic ideals vary with emerging fashion trends and within different cultures. However, over the past few decades, fuller lips have been considered a desirable trait. Many younger patients are presenting for lip augmentation to achieve the sought-after look commonly seen in many fashion magazines. In addition, as individuals age, they lose lip volume, with a thinning of the red lip, some effacement of the vermillion border, and elongation and flattening of the white portion of the lip. Rejuvenation of the lips plays a key role in restoring a more youthful appearance. As a result, lip augmentation appeals to a wide spectrum of patients who present with various different aesthetic goals and expectations. Numerous therapeutic options exist for aesthetic lip augmentation, ranging from temporary and permanent injectable fillers to implants and other surgical techniques.

  19. Augmented Cognitive Behavioral Therapy for Poststroke Depressive Symptoms: A Randomized Controlled Trial.

    Science.gov (United States)

    Kootker, Joyce A; Rasquin, Sascha M C; Lem, Frederik C; van Heugten, Caroline M; Fasotti, Luciano; Geurts, Alexander C H

    2017-04-01

    To evaluate the effectiveness of individually tailored cognitive behavioral therapy (CBT) for reducing depressive symptoms with or without anxiety poststroke. Multicenter, assessor-blinded, randomized controlled trial. Ambulatory rehabilitation setting. Patients who had a Hospital Anxiety and Depression Scale-depression subscale (HADS-D) score >7 at least 3 months poststroke (N=61). Participants were randomly allocated to either augmented CBT or computerized cognitive training (CCT). The CBT intervention was based on the principles of recognizing, registering, and altering negative thoughts and cognitions. CBT was augmented with goal-directed real-life activity training given by an occupational or movement therapist. HADS-D was the primary outcome, and measures of participation and quality of life were secondary outcomes. Outcome measurements were performed at baseline, immediately posttreatment, and at 4- and 8-month follow-up. Analysis was performed with linear mixed models using group (CBT vs CCT) as the between-subjects factor and time (4 assessments) as the within-subjects factor. Mixed model analyses showed a significant and persistent time effect for HADS-D (mean difference, -4.6; 95% confidence interval, -5.7 to -3.6; P<.001) and for participation and quality of life in both groups. There was no significant group × time effect for any of the outcome measures. Our augmented CBT intervention was not superior to CCT for the treatment of mood disorders after stroke. Future studies should determine whether both interventions are better than natural history. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  20. Augmented Reality Interfaces for Additive Manufacturing

    DEFF Research Database (Denmark)

    Eiríksson, Eyþór Rúnar; Pedersen, David Bue; Frisvad, Jeppe Revall

    2017-01-01

    This paper explores potential use cases for using augmented reality (AR) as a tool to operate industrial machines. As a baseline we use an additive manufacturing system, more commonly known as a 3D printer. We implement novel augmented interfaces and controls using readily available open source...

  1. Affordances in Mobile Augmented Reality Applications

    Directory of Open Access Journals (Sweden)

    Tor Gjøsæter

    2014-10-01

    Full Text Available This paper explores the affordances of augmented reality content in a mobile augmented reality application. A user study was conducted by performing a multi-camera video recording of seven think aloud sessions. The think aloud sessions consisted of individual users performing tasks, exploring and experiencing a mobile augmented reality (MAR application we developed for the iOS platform named ARad. We discuss the instrumental affordances we observed when users interacted with augmented reality content, as well as more complex affordances rising from conventions from media content, AR and the traditional WIMP paradigm. We find that remediation of traditional newspaper content through the MAR medium can provide engaging, pleasing and exciting user experiences. However, the some of the content still suffers from being shoveled onto the MAR platform without adapting it properly. Finally, we discuss what content was most successfully mediated to the user and how the content impacts the user experience.

  2. Filler migration and extensive lesions after lip augmentation: Adverse effects of polydimethylsiloxane filler.

    Science.gov (United States)

    Abtahi-Naeini, Bahareh; Faghihi, Gita; Shahmoradi, Zabihollah; Saffaei, Ali

    2018-01-07

    Polydimethylsiloxane (PDMS), also called liquid silicone, belongs to a group of polymeric compounds that are commonly referred to as silicones. These filling agents have been used as injectable filler for soft tissue augmentation. There are limited experiences about management of the severe complications related to filler migration associated with PDMS injection. We present a 35-year-old female with severe erythema, edema over her cheeks and neck, and multiple irregularities following cosmetic lip augmentation with PDMS. Further studies are required for management of this complicated case of PDMS injection. © 2018 Wiley Periodicals, Inc.

  3. Ex vivo biomechanical evaluation of pigeon (Columba livia) cadaver intact humeri and ostectomized humeri stabilized with caudally applied titanium locking plate or stainless steel nonlocking plate constructs.

    Science.gov (United States)

    Darrow, Brett G; Biskup, Jeffrey J; Weigel, Joseph P; Jones, Michael P; Xie, Xie; Liaw, Peter K; Tharpe, Josh L; Sharma, Aashish; Penumadu, Dayakar

    2017-05-01

    OBJECTIVE To evaluate mechanical properties of pigeon (Columba livia) cadaver intact humeri versus ostectomized humeri stabilized with a locking or nonlocking plate. SAMPLE 30 humeri from pigeon cadavers. PROCEDURES Specimens were allocated into 3 groups and tested in bending and torsion. Results for intact pigeon humeri were compared with results for ostectomized humeri repaired with a titanium 1.6-mm screw locking plate or a stainless steel 1.5-mm dynamic compression plate; the ostectomized humeri mimicked a fracture in a thin cortical bone. Locking plates were secured with locking screws (2 bicortical and 4 monocortical), and nonlocking plates were secured with bicortical nonlocking screws. Constructs were cyclically tested nondestructively in 4-point bending and then tested to failure in bending. A second set of constructs were cyclically tested non-destructively and then to failure in torsion. Stiffness, strength, and strain energy of each construct were compared. RESULTS Intact specimens were stiffer and stronger than the repair groups for all testing methods, except for nonlocking constructs, which were significantly stiffer than intact specimens under cyclic bending. Intact bones had significantly higher strain energies than locking plates in both bending and torsion. Locking and nonlocking plates were of equal strength and strain energy, but not stiffness, in bending and were of equal strength, stiffness, and strain energy in torsion. CONCLUSIONS AND CLINICAL RELEVANCE Results for this study suggested that increased torsional strength may be needed before bone plate repair can be considered as the sole fixation method for avian species.

  4. Achilles Tendon Open Surgical Treatment With Platelet-Rich Fibrin Matrix Augmentation: Biomechanical Evaluation.

    Science.gov (United States)

    Alviti, Federica; Gurzì, Michele; Santilli, Valter; Paoloni, Marco; Padua, Roberto; Bernetti, Andrea; Bernardi, Marco; Mangone, Massimiliano

    The relationship between surgical technique and ankle biomechanical properties after surgery for acute rupture of the Achilles tendon (ATR) has not yet been fully investigated. Platelet-rich fibrin (PRF) matrices seem to play a central role in the complex processes of tendon healing. Our aim was to analyze the biomechanical characteristics, stiffness, and mechanical work of the ankle during walking in patients who had undergone surgery after ATR with and without PRF augmentation. We performed a retrospective review of all consecutive patients who had been treated with surgical repair after ATR. Of the 20 male subjects enrolled, 9 (45%) had undergone conventional open repair of the Achilles tendon using the Krackow technique (no-PRF) and 11 (55%) had undergone surgery with PRF augmentation. An additional 8 healthy subjects were included as a control group. A gait analysis evaluation was performed at 6 months after surgery. The percentage of the stance time of the operated leg, double-support time of the healthy leg, and net work of the ankle during the gait cycle showed statistically significant differences between the no-PRF and the healthy group (p < .005). No differences were found between the PRF and healthy groups. Treatment with suture and PRF augmentation could result in significant functional improvements in term of efficiency of motion. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Augmented reality in surgery.

    Science.gov (United States)

    Shuhaiber, Jeffrey H

    2004-02-01

    To evaluate the history and current knowledge of computer-augmented reality in the field of surgery and its potential goals in education, surgeon training, and patient treatment. National Library of Medicine's database and additional library searches. Only articles suited to surgical sciences with a well-defined aim of study, methodology, and precise description of outcome were included. Augmented reality is an effective tool in executing surgical procedures requiring low-performance surgical dexterity; it remains a science determined mainly by stereotactic registration and ergonomics. Strong evidence was found that it is an effective teaching tool for training residents. Weaker evidence was found to suggest a significant influence on surgical outcome, both morbidity and mortality. No evidence of cost-effectiveness was found. Augmented reality is a new approach in executing detailed surgical operations. Although its application is in a preliminary stage, further research is needed to evaluate its long-term clinical impact on patients, surgeons, and hospital administrators. Its widespread use and the universal transfer of such technology remains limited until there is a better understanding of registration and ergonomics.

  6. CIRP Interlaboratory Comparison of Coordinate Measuring Machines using an Optomechanical Hole Plate - Final Report

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Hansen, Hans Nørgaard; Morace, Renata Erica

    2005-01-01

    be expected that the optomechanical hole plates can be calibrated using the DKD procedure with an uncertainty in the range between 0.5 µm and 2 µm. Using the hole plate, it is possible to compare the performance of measurements obtained using optical and mechanical CMMs. Optical CMM measurements can...... be divided in two groups. A group leading to deviations larger than 2 µm, and a group with deviations that are comparable to those using mechanical machines. All but one laboratory could perform reversal measurements. Transfer of traceability was established as follows: 8 using gauge blocks, 2 laser...... interferometers, 1 zerodur hole plate, 2 callipers, and 1 quartz standard. Out of the 23 measurement campaigns, 5 optical and 2 mechanical machines were not provided with establishment of traceability. The optomechanical hole plate is a suitable reference artefact providing traceability of CMMs, in particular...

  7. Can oxytocin augmentation modify the risk of epidural analgesia by maternal age in cesarean sections?

    DEFF Research Database (Denmark)

    Rossen, Janne; Klungsøyr, Kari; Albrechtsen, Susanne

    2018-01-01

    was used compared with when it was not used. In Norway, this applied to all maternal age groups but in Denmark only for women ≥30 years. Among women without epidural, oxytocin augmentation was associated with an increased odds ratio for cesarean section in Denmark, whereas no difference was observed....... MATERIAL AND METHODS: In all, 416 386 nulliparous women with spontaneous onset of labor, ≥37 weeks of gestation and singleton infants with a cephalic presentation during 2000-2011 from Norway and Denmark were included [Ten-group classification system (Robson) group 1]. In this case-control study the main...... exposure was maternal age; epidural analgesia, oxytocin augmentation, birthweight and time period were explanatory variables. Chi-square test and logistic regression were used to estimate associations and interactions. RESULTS: The cesarean section rate increased consistently with advancing maternal age...

  8. Enhancing tourism with augmented and virtual reality

    OpenAIRE

    Jenny, Sandra

    2017-01-01

    Augmented and virtual reality are on the advance. In the last twelve months, several interesting devices have entered the market. Since tourism is one of the fastest growing economic sectors in the world and has become one of the major players in international commerce, the aim of this thesis was to examine how tourism could be enhanced with augmented and virtual reality. The differences and functional principles of augmented and virtual reality were investigated, general uses were described ...

  9. Augmented Reality: Daily Prayers for Preschooler Student

    Directory of Open Access Journals (Sweden)

    Hendra Pradibta

    2018-01-01

    Full Text Available Education is one of the aspects that many synthesized with technology. Yet, this is contrary to the fact that where most of the learning materials are still based on text. This research aims to develop an alternative learning media by implementing Augmented Reality Technology for Preschooler students. Augmented Reality (AR is an application that can combine the virtual object as text, pictures and animation into the real world. Development of Augmented Reality application uses Web Aurasma Based Studio, with learning materials of daily prayer for preschool student. The development of the characters and the animations were using Adobe Illustrator and Adobe After Effects. The results of the study showed that technology Augmented Reality can be used as an alternative learning media especially in the learning process in Preschool Al Furqon. This is because the content Augmented Reality in the form of animation can gives more understanding and attention for preschool student to follow the learning process

  10. Sonographic and MRI evaluation of the plantar plate: a prospective study

    International Nuclear Information System (INIS)

    Gregg, Julie; Silberstein, Morry; Schneider, Timothy; Marks, Paul

    2006-01-01

    The purpose of this study was to establish the accuracy of ultrasound in the examination of the plantar plate by comparing it with MRI, or if available, surgical findings. The lesser metatarsophalangeal joint plantar plates of 40 symptomatic and 40 asymptomatic feet (160 asymptomatic and 160 symptomatic plantar plates) were examined with ultrasound and MRI. Patients treated with surgery were chosen on a clinical basis and provided surgical correlation for the imaging techniques. Symptomatic patients with metatatarsalgia and suspected metatarsophalangeal joint instability were referred by an orthopedic foot specialist; asymptomatic feet were obtained either through examination of the contralateral foot of the symptomatic patients or volunteers. Ultrasound detected 75/160 and 139/160 plantar plates torn in the asymptomatic and symptomatic groups, respectively. MRI detected 56/160 and 142/160 tears in the symptomatic and asymptomatic groups, respectively. The sensitivity of MRI and ultrasound with surgical correlation was calculated to be 87 and 96%, respectively, with poor specificity. Ultrasound correlates moderately with MRI in the evaluation of the plantar plate. Surgical correlations, although limited (n=10), indicate ultrasound is superior to MRI with more accurate detection of tears. (orig.)

  11. Indian red scorpion venom-induced augmentation of cardio-respiratory reflexes and pulmonary edema involve the release of histamine.

    Science.gov (United States)

    Dutta, Abhaya; Deshpande, Shripad B

    2011-02-01

    Pulmonary edema is a consistent feature of Mesobuthus tamulus (MBT) envenomation. Kinins, prostaglandins and other inflammatory mediators are implicated in it. Since, histamine also increases capillary permeability, this study was undertaken to evaluate whether MBT venom utilizes histamine to produce pulmonary edema and augmentation of cardio-respiratory reflexes evoked by phenylbiguanide (PBG). Blood pressure, respiratory excursions and ECG were recorded in urethane anaesthetized adult rats. Injection of PBG (10 μg/kg) produced apnoea, hypotension and bradycardia and the responses were augmented after exposure to venom (100 μg/kg). There was increased pulmonary water content in these animals. Pretreatment with pheniramine maleate (H₁ antagonist, 3 mg/kg) blocked both venom-induced augmentation of PBG response and pulmonary edema. In another series, compound 48/80 (mast cell depletor) was treated for 4 days then the PBG responses were elicited as before. At the end of the experiments, mast cells were counted from the peritoneal fluid. The venom-induced pulmonary edema and the augmentation of PBG reflex were not observed in compound 48/80 treated animals. Further, mast cells in the peritoneal fluid were absent in this group as compared to vehicle treated group (29 ± 7.9 cells/mm³). These observations indicate that venom-induced pulmonary edema and augmentation of PBG reflexe are mediated through mast cells by involving H₁ receptors. Copyright © 2010 Elsevier Ltd. All rights reserved.

  12. From Augmentation Media to Meme Media.

    Science.gov (United States)

    Tanaka, Yuzuru

    Computers as meta media are now evolving from augmentation media vehicles to meme media vehicles. While an augmentation media system provides a seamlessly integrated environment of various tools and documents, meme media system provides further functions to edit and distribute tools and documents. Documents and tools on meme media can easily…

  13. Potential costs of breast augmentation mammaplasty.

    Science.gov (United States)

    Schmitt, William P; Eichhorn, Mitchell G; Ford, Ronald D

    2016-01-01

    Augmentation mammaplasty is one of the most common surgical procedures performed by plastic surgeons. The aim of this study was to estimate the cost of the initial procedure and its subsequent complications, as well as project the cost of Food and Drug Administration (FDA)-recommended surveillance imaging. The potential costs to the individual patient and society were calculated. Local plastic surgeons provided billing data for the initial primary silicone augmentation and reoperative procedures. Complication rates used for the cost analysis were obtained from the Allergen Core study on silicone implants. Imaging surveillance costs were considered in the estimations. The average baseline initial cost of silicone augmentation mammaplasty was calculated at $6335. The average total cost of primary breast augmentation over the first decade for an individual patient, including complications requiring reoperation and other ancillary costs, was calculated at $8226. Each decade thereafter cost an additional $1891. Costs may exceed $15,000 over an averaged lifetime, and the recommended implant surveillance could cost an additional $33,750. The potential cost of a breast augmentation, which includes the costs of complications and imaging, is significantly higher than the initial cost of the procedure. Level III, economic and decision analysis study. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  14. The Augmented REality Sandtable (ARES)

    Science.gov (United States)

    2015-10-01

    Introduction The US Army Research Laboratory (ARL) Human Sciences Campaign calls out the topic of Virtual /Mixed and Augmented Reality as one of the...type of virtual environment. In virtual reality (VR), the totality of the environment is computer generated. In AR, the real world is augmented by...tangible user interfaces; and the effectiveness of virtual sand tables and similar systems. A market survey was also done to discover the state of

  15. Biomechanical evaluation of a new MatrixMandible plating system on cadaver mandibles.

    Science.gov (United States)

    Gateno, Jaime; Cookston, Christopher; Hsu, Sam Sheng-Pin; Stal, Drew N; Durrani, Salim K; Gold, Jonathan; Ismaily, Sabir; Alexander, Jerry W; Noble, Philip C; Xia, James J

    2013-11-01

    Current mandibular plating systems contain a wide range of plates and screws needed for the treatment of mandibular reconstruction and mandibular fractures. The authors' hypothesis was that a single diameter screw could be used in all applications in a plating system. Therefore, the purpose of this study was to test if the 2.0-mm locking screws could replace the 2.4-mm screws to stabilize a 2.5-mm-thick reconstruction plate in the treatment of mandibular discontinuity. Thirty-six fresh human cadaveric mandibles were used: 18 were plated using 2.0-mm locking screws (experimental) and the other 18 were plated using 2.4-mm locking screws (control). Each group was further divided into 3 subgroups based on the site of loading application: the ipsilateral (right) second premolar region, the central incisal region, and the contralateral (left) first molar region. The same ipsilateral (right) mandibular angular discontinuity was created by the same surgeon. The mandible was mounted on a material testing machine. The micromotions between the 2 segments, permanent and elastic displacements, were recorded after incremental ramping loads. The magnitude of screw back-out and the separation between plate and bone were recorded using a laser scanner (resolution, 0.12 mm) before and after the loading applications. The data were processed. Descriptive analyses and a general linear model for repeated measures analysis of variance were performed. There was no statistically significant difference in permanent displacement (mean, 1.16 and 0.82 mm, respectively) between the 2.0-mm and 2.4-mm screw groups. There also was no statistically significant difference in elastic displacement between the 2 groups (mean, 1.48 and 1.21 mm, respectively). Finally, there were no statistically significant differences in screw back-out or separation between plate and bone between the 2 groups. All means for screw back-out and separation between screw and bone for each group were judged within the

  16. Augmented Reality: Daily Prayers for Preschooler Student

    OpenAIRE

    Hendra Pradibta

    2018-01-01

    Education is one of the aspects that many synthesized with technology. Yet, this is contrary to the fact that where most of the learning materials are still based on text. This research aims to develop an alternative learning media by implementing Augmented Reality Technology for Preschooler students. Augmented Reality (AR) is an application that can combine the virtual object as text, pictures and animation into the real world. Development of Augmented Reality application uses Web Aurasma Ba...

  17. Advanced Modelling of Trusses with Punched Metal Plate Fasteners

    DEFF Research Database (Denmark)

    Ellegaard, Peter; Nielsen, Jacob

    Most of the finite element programs for design of timber trusses with punched metal fasteners are based on models using beam and fictitious elements. Different models have been used for different types of joints. Common problems for all the models are how to calculate the forces in the nail groups...... and the plates and furthermore, how big 'the deformations in the joints are. By developing an advanced model that includes all parts of the joint, i.e. plate, nail groups and contact it is possible to give a better description of the joint. An advanced model with these properties is presented. The advanced model...

  18. Applied Augmented Reality for High Precision Maintenance

    Science.gov (United States)

    Dever, Clark

    Augmented Reality had a major consumer breakthrough this year with Pokemon Go. The underlying technologies that made that app a success with gamers can be applied to improve the efficiency and efficacy of workers. This session will explore some of the use cases for augmented reality in an industrial environment. In doing so, the environmental impacts and human factors that must be considered will be explored. Additionally, the sensors, algorithms, and visualization techniques used to realize augmented reality will be discussed. The benefits of augmented reality solutions in industrial environments include automated data recording, improved quality assurance, reduction in training costs and improved mean-time-to-resolution. As technology continues to follow Moore's law, more applications will become feasible as performance-per-dollar increases across all system components.

  19. Augmented Reality in Tourism - Research and Applications Overview

    Directory of Open Access Journals (Sweden)

    Anabel L. Kečkeš

    2017-06-01

    Full Text Available Augmented reality is a complex interdisciplinary field utilizing information technologies in diverse areas such as medicine, education, architecture, industry, tourism and others, augmenting the real-time, real-world view with additional superimposed information in chosen format(s. The aim of this paper is to present an overview of both research and application aspects of using augmented reality technologies in tourism domain. While most research, and especially applications, are dealing with and developing visual-based augmented reality systems, there is a relevant amount of research discussing the utilization of other human senses such as tactioception and audioception, both being discussed within this work. A comprehensive literature analysis within this paper resulted with the identification, compilation and categorization of the key factors having the most relevant impact on the success of utilization of augmented technology in tourism domain.

  20. Integrating photo-stimulable phosphor plates into dental and dental hygiene radiography curricula.

    Science.gov (United States)

    Tax, Cara L; Robb, Christine L; Brillant, Martha G S; Doucette, Heather J

    2013-11-01

    It is not known whether the integration of photo-stimulable phosphor (PSP) plates into dental and dental hygiene curricula creates unique learning challenges for students. The purpose of this two-year study was to determine if dental hygiene students had more and/or different types of errors when using PSP plates compared to film and whether the PSP imaging plates had any particular characteristics that needed to be addressed in the learning process. Fifty-nine first-year dental hygiene students at one Canadian dental school were randomly assigned to two groups (PSP or film) before exposing their initial full mouth series on a teaching manikin using the parallel technique. The principal investigator determined the number and types of errors based on a specific set of performance criteria. The two groups (PSP vs. film) were compared for total number and type of errors made. Results of the study indicated the difference in the total number of errors made using PSP or film was not statistically significant; however, there was a difference in the types of errors made, with the PSP group having more horizontal errors than the film group. In addition, the study identified a number of unique characteristics of the PSP plates that required special consideration for teaching this technology.

  1. Does Subacromial Osteolysis Affect Shoulder Function after Clavicle Hook Plating?

    Directory of Open Access Journals (Sweden)

    Siwei Sun

    2016-01-01

    Full Text Available Purpose. To evaluate whether subacromial osteolysis, one of the major complications of the clavicle hook plate procedure, affects shoulder function. Methods. We had performed a retrospective study of 72 patients diagnosed with a Neer II lateral clavicle fracture or Degree-III acromioclavicular joint dislocation in our hospital from July 2012 to December 2013. All these patients had undergone surgery with clavicle hook plate and were divided into two groups based on the occurrence of subacromial osteolysis. By using the Constant-Murley at the first follow-up visit after plates removal, we evaluated patients’ shoulder function to judge if it has been affected by subacromial osteolysis. Results. We have analyzed clinical data for these 72 patients, which shows that there is no significant difference between group A (39 patients and group B (33 patients in age, gender, injury types or side, and shoulder function (the Constant-Murley scores are 93.38±3.56 versus 94.24±3.60, P>0.05. Conclusion. The occurrence of subacromial osteolysis is not rare, and also it does not significantly affect shoulder function.

  2. A Possible Differentially Shortened Strike-slip Plate Boundary: the Okhotsk Plate Example.

    Science.gov (United States)

    Hindle, D.; Egorov, V.; Mackey, K. G.; Fujita, K.

    2004-12-01

    The Okhotsk plate has been postulated based on a combination of GPS geodetic inversions (REVEL1), seimsicity, geologic and lineament data. Lying between the North American and Eurasian plates, its northwestern corner would appear to be undergoing compression in a scissors motion between the two bounding plates. Extrusion tectonics along multiple, large strike-slip faults within the Okhotsk plate itself have been suggested to allow the escape of material away from the apex of Eurasia-North America. The plate boundary between Okhotsk and North America has been suggested to be diffuse, based on widely scattered minor seismicity. However, the large, left lateral, Ulakhan fault has also been suggested as a candidate plate boundary. We present field geological and geomorphological evidence of the partitioning of deformation between the Ulakhan fault, and several parallel and oblique, linked faults. The Ulakhan fault strand appears to have a maximum displacement of 24 km based on river valley offsets and closing large pull apart basins. Some of the displacement from the Ulakhan fault appears relayed into the plate margin along oblique trending, thrust/oblique slip faults. Estimated shortening over these faults is equivalent to the amount of shortening relayed into the plate margin from the plate boundary. There may be several thrust/oblique slip faults along the Ulakhan fault, which leads to the interesting situation of a segmented, strike-slip plate boundary being actively shortened in a margin parallel direction. This may be the result of postulated extrusion of the Okhotsk plate due to North America/Eurasia convergence. Such a situation would have important consequences for the interpretation of GPS data in a plate tectonic context.

  3. Alternative realities : from augmented reality to mobile mixed reality

    OpenAIRE

    Claydon, Mark

    2015-01-01

    This thesis provides an overview of (mobile) augmented and mixed reality by clarifying the different concepts of reality, briefly covering the technology behind mobile augmented and mixed reality systems, conducting a concise survey of existing and emerging mobile augmented and mixed reality applications and devices. Based on the previous analysis and the survey, this work will next attempt to assess what mobile augmented and mixed reality could make possible, and what related applications an...

  4. Chin augmentation - slideshow

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/presentations/100009.htm Chin augmentation - series—Normal anatomy To use the sharing features ... Bethesda, MD 20894 U.S. Department of Health and Human Services National Institutes of Health Page last updated: ...

  5. Breast augmentation - slideshow

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/presentations/100205.htm Breast augmentation - series—Normal anatomy To use the sharing features ... Bethesda, MD 20894 U.S. Department of Health and Human Services National Institutes of Health Page last updated: ...

  6. Hypothesis-driven methods to augment human cognition by optimizing cortical oscillations

    Directory of Open Access Journals (Sweden)

    Jörn M. Horschig

    2014-06-01

    Full Text Available Cortical oscillations have been shown to represent fundamental functions of a working brain, e.g. communication, stimulus binding, error monitoring, and inhibition, and are directly linked to behavior. Recent studies intervening with these oscillations have demonstrated effective modulation of both the oscillations and behavior. In this review, we collect evidence in favor of how hypothesis-driven methods can be used to augment cognition by optimizing cortical oscillations. We elaborate their potential usefulness for three target groups: healthy elderly, patients with attention deficit/hyperactivity disorder, and healthy young adults. We discuss the relevance of neuronal oscillations in each group and show how each of them can benefit from the manipulation of functionally-related oscillations. Further, we describe methods for manipulation of neuronal oscillations including direct brain stimulation as well as indirect task alterations. We also discuss practical considerations about the proposed techniques. In conclusion, we propose that insights from neuroscience should guide techniques to augment human cognition, which in turn can provide a better understanding of how the human brain works.

  7. Augmented reality-assisted skull base surgery.

    Science.gov (United States)

    Cabrilo, I; Sarrafzadeh, A; Bijlenga, P; Landis, B N; Schaller, K

    2014-12-01

    Neuronavigation is widely considered as a valuable tool during skull base surgery. Advances in neuronavigation technology, with the integration of augmented reality, present advantages over traditional point-based neuronavigation. However, this development has not yet made its way into routine surgical practice, possibly due to a lack of acquaintance with these systems. In this report, we illustrate the usefulness and easy application of augmented reality-based neuronavigation through a case example of a patient with a clivus chordoma. We also demonstrate how augmented reality can help throughout all phases of a skull base procedure, from the verification of neuronavigation accuracy to intraoperative image-guidance. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  8. Enhancing Education through Mobile Augmented Reality

    Science.gov (United States)

    Joan, D. R. Robert

    2015-01-01

    In this article, the author has discussed about the Mobile Augmented Reality and enhancing education through it. The aim of the present study was to give some general information about mobile augmented reality which helps to boost education. Purpose of the current study reveals the mobile networks which are used in the institution campus as well…

  9. Augmented Reality as a Countermeasure for Sleep Deprivation.

    Science.gov (United States)

    Baumeister, James; Dorrlan, Jillian; Banks, Siobhan; Chatburn, Alex; Smith, Ross T; Carskadon, Mary A; Lushington, Kurt; Thomas, Bruce H

    2016-04-01

    Sleep deprivation is known to have serious deleterious effects on executive functioning and job performance. Augmented reality has an ability to place pertinent information at the fore, guiding visual focus and reducing instructional complexity. This paper presents a study to explore how spatial augmented reality instructions impact procedural task performance on sleep deprived users. The user study was conducted to examine performance on a procedural task at six time points over the course of a night of total sleep deprivation. Tasks were provided either by spatial augmented reality-based projections or on an adjacent monitor. The results indicate that participant errors significantly increased with the monitor condition when sleep deprived. The augmented reality condition exhibited a positive influence with participant errors and completion time having no significant increase when sleep deprived. The results of our study show that spatial augmented reality is an effective sleep deprivation countermeasure under laboratory conditions.

  10. Initial Model of Social Acceptability for Human Augmentation Technologies

    NARCIS (Netherlands)

    Eghtebas, Chloe; Pay, Yun Suen; Väänänen, Kaisa; Pfeiffer, Ties; Meyer, Joachim; Lukosch, S.G.

    2017-01-01

    Academia and industry engage in major efforts to develop technologies for augmenting human senses and activities. Many of these technologies, such as augmented reality (AR) and virtual reality (VR) head mounted displays (HMD), haptic augmentation systems, and exoskeletons can be applied in numerous

  11. Media-Augmented Exercise Machines

    Science.gov (United States)

    Krueger, T.

    2002-01-01

    Cardio-vascular exercise has been used to mitigate the muscle and cardiac atrophy associated with adaptation to micro-gravity environments. Several hours per day may be required. In confined spaces and long duration missions this kind of exercise is inevitably repetitive and rapidly becomes uninteresting. At the same time, there are pressures to accomplish as much as possible given the cost- per-hour for humans occupying orbiting or interplanetary. Media augmentation provides a the means to overlap activities in time by supplementing the exercise with social, recreational, training or collaborative activities and thereby reducing time pressures. In addition, the machine functions as an interface to a wide range of digital environments allowing for spatial variety in an otherwise confined environment. We hypothesize that the adoption of media augmented exercise machines will have a positive effect on psycho-social well-being on long duration missions. By organizing and supplementing exercise machines, data acquisition hardware, computers and displays into an interacting system this proposal increases functionality with limited additional mass. This paper reviews preliminary work on a project to augment exercise equipment in a manner that addresses these issues and at the same time opens possibilities for additional benefits. A testbed augmented exercise machine uses a specialty built cycle trainer as both input to a virtual environment and as an output device from it using spatialized sound, and visual displays, vibration transducers and variable resistance. The resulting interactivity increases a sense of engagement in the exercise, provides a rich experience of the digital environments. Activities in the virtual environment and accompanying physiological and psychological indicators may be correlated to track and evaluate the health of the crew.

  12. Epiphyseal plate closure of radio-ulna bone in red Sokoto goat ...

    African Journals Online (AJOL)

    They were classified into different age groups and subgroups, from 1-144 weeks. The radiographs of their forearms were taken and the proximal and distal epiphyseal plate lengths of both radius and ulna bones were measured. The radiographic images of the bones showed that the proximal and distal epiphyseal plates of ...

  13. Fratura distal do rádio em pacientes com mais de 60 anos: placas ortogonais versus placa volar Distal radial fractures in patients over 60 years old: orthogonal plates versus volar plate

    Directory of Open Access Journals (Sweden)

    Edgard Novaes de França Bisneto

    2010-01-01

    Full Text Available OBJETIVO: Comparar os resultados do tratamento cirúrgico entre placa volar com estabilidade angular e placas ortogonais em fraturas instáveis de rádio distal em pacientes com mais de 60 anos. MÉTODOS: Pacientes foram divididos em dois grupos tratados com placa volar ou placas ortogonais. Resultados clínicos e radiográficos foram analisados prospectivamente. RESULTADOS: Os grupos de estudo apresentaram resultados clínicos e radiográficos semelhantes seis meses após a operação. No entanto três meses após a cirurgia, o grupo onde foi utilizada a placa volar obteve resultados superiores. CONCLUSÃO: Ambos os grupos apresentaram bons resultados funcionais. O tratamento cirúrgico facilita a reabilitação precoce. A técnica das placas ortogonais requer uma curva de aprendizado maior e apresentou mais complicações e piores resultados iniciais.OBJECTIVE: To compare the results from surgical treatment between volar plates with angular stability and orthogonal plates of unstable distal radius fractures in patients aged over 60 years. METHODS: Selected patients were randomized in two groups treated with volar plates or orthogonal plates. Clinic al and radiographic results were analyzed prospectively. RESULTS: The study groups presented similar clinical and radiographic results six months after the operation. However three months after surgery the volar plate group obtained superior results considering most of the parameters studied. CONCLUSION: Both the volar plates and the orthogonal plates presented good functional results. Surgical treatment enabled early rehabilitation for these patients. Orthogonal plate technique required a longer learning curve, presented more complications and worst early results.

  14. Phenobarbital Augments Hypothermic Neuroprotection

    Science.gov (United States)

    Barks, John D.; Liu, Yi-Qing; Shangguan, Yu; Silverstein, Faye S.

    2010-01-01

    Seizures are associated with adverse outcome in infants with hypoxic-ischemic encephalopathy. We hypothesized that early administration of the anticonvulsant phenobarbital after cerebral hypoxia-ischemia could enhance the neuroprotective efficacy of delayed-onset hypothermia. We tested this hypothesis in a neonatal rodent model. Seven-day-old rats (n=104) underwent right carotid ligation, followed by 90 min 8%O2 exposure; 15 min later, they received injections of phenobarbital (40 mg/kg) or saline. One or 3h later, all were treated with hypothermia (30°C, 3h). Function and neuropathology were evaluated after 7 days (“early outcomes”) or 1 month (“late outcomes”). Early outcome assessment demonstrated better sensorimotor performance and less cortical damage in phenobarbital-treated groups; there were no differences between groups in which the hypothermia delay was shortened from 3h to 1h. Late outcome assessment confirmed sustained benefits of phenobarbital+hypothermia treatment; sensorimotor performance was better (persistent attenuation of contralateral forepaw placing deficits and absence of contralateral forepaw neglect); neuropathology scores were lower (medians, phenobarbital 2, saline 8.5, pphenobarbital may augment the neuroprotective efficacy of therapeutic hypothermia. PMID:20098339

  15. Effect of Plate Curvature on Blast Response of Structural Steel Plates

    Science.gov (United States)

    Veeredhi, Lakshmi Shireen Banu; Ramana Rao, N. V.; Veeredhi, Vasudeva Rao

    2018-04-01

    In the present work an attempt is made, through simulation studies, to determine the effect of plate curvature on the blast response of a door structure made of ASTM A515 grade 50 steel plates. A door structure with dimensions of 5.142 m × 2.56 m × 10 mm having six different radii of curvatures is analyzed which is subjected to blast load. The radii of curvature investigated are infinity (flat plate), 16.63, 10.81, 8.26, 6.61 and 5.56 m. In the present study, a stand-off distance of 11 m is considered for all the cases. Results showed that the door structure with smallest radius of curvature experienced least plastic deformation and yielding when compared to a door with larger radius of curvature with same projected area. From the present Investigation, it is observed that, as the radius of curvature of the plate increases, the deformation mode gradually shifts from indentation mode to flexural mode. The plates with infinity and 16.63 m radius of curvature have undergone flexural mode of deformation and plates with 6.61 and 5.56 m radius of curvature undergo indentation mode of deformation. Whereas, mixed mode of deformation that consists of both flexural and indentation mode of deformations are seen in the plates with radius of curvature 10.81 and 8.26 m. As the radius of curvature of the plate decreases the ability of the plate to mitigate the effect the blast loads increased. It is observed that the plate with smaller radius of curvature deflects most of the blast energy and results in least indentation mode of deformation. The most significant observation made in the present investigation is that the strain energy absorbed by the steel plate gets reduced to 1/3 rd when the radius of curvature is approximately equal to the stand-off distance which could be the critical radius of curvature.

  16. OUTCOME OF LOCKING PLATES IN DISTAL TIBIA FRACTURES TREATMENT

    Directory of Open Access Journals (Sweden)

    Lokesh

    2016-05-01

    Full Text Available INTRODUCTION Most of these fractures except intra-articular fractures are treated with interlocking nail. 1,2 These nails are a boon for these fractures. But as the fracture nears to the joint stability the fracture fixation will be compromised due to malreduction and alignment, it leads to increased chances of delayed and nonunion. 3 Locking anatomical plates are evaluated for anatomical and relative stability fixation. Since then most intra and near intra-articular fractures are fixed with these plates with minimally invasive percutaneous plate osteosynthesis method, these plates have given excellent result 4 . But again these plates have some disadvantages 5 . This study is done to see the outcome of locking plates in distal tibia fracture. METHODS This study is done in the Department of Orthopaedics, Bangalore Medical College, Bangalore. This study is done from 2013 to 2015. 30 patients who came to outpatient department were treated with locking plates. All patients above 16 years having distal third tibia fracture are included. All open fractures except type 1 and elderly above 60 years and pathological fractures are excluded in our study. All patients were followed up for initial 5 months, thereafter, once in 3 months, for clinical and radiological evaluation of union status, knee range of motion, ankle range of motion and other complications. Assessment of the patient with functional recovery was done with American Orthopaedic Foot and Ankle Surgery(AOFAS 6 minimum 5 months after injury. RESULTS Majority of the patients are from age group 18-29 years (50%. Average age group was 30 years. Majority of the patients were males 80.6% (25. All fractures were closed fractures except 2 cases which are type 1. There were 12 cases of AO type A, 8 patients were AO type B and 10 patients were type C. Majority of the patients had fracture due to road traffic accidents, 74%. All fractures were united by the end of 20 weeks. There was delayed union in

  17. The Okhotsk Plate and the Eurasia-North America plate boundary zone.

    Science.gov (United States)

    Hindle, David; Mackey, Kevin

    2014-05-01

    The Eurasia-North America plate boundary zone transitions from spreading at rates of ~ 25mm/yr in the North Atlantic, to compression at rates of ~ 5mm/yr in the region of the Okhotsk plate. Because the pole of rotation between Eurasia and North America lies more or less on their mutual boundary, there is a linear change in rate along the boundary, and regions near the euler pole are subject to extremely low deformation rates. The Okhotsk - Eurasia - North America triple junction lies slightly south of the rotation pole, placing the Okhotsk plate entirely in a weakly contractional setting. Regions near the triple junction absorb 1mm/yr contraction. Further south, towards the shoreline of the Okhotsk sea, up to 5 mm/yr contraction may be absorbed within the plate. How shortening is accommodated across the boundary remains an open question. One possibility is wholesale extrusion of the entire Okhotsk plate (or possibly its northwestern corner) along two plate boundary strike slip faults (Eurasia-Okhostk and North America Okhotsk). The problem with this model is that the seismic record does not presently clearly support it, with the largest events distributed both within the plate interior and on its boundaries. This may suggest that instead, the Okhotsk plate, and particularly its north-western end, consists of a series of smaller blocks which shuffle against each other, partially accommodating extrusion, but also permitting some internal deformation and change of shape of the Okhotsk plate itself. We present analyses of the very sparse seismic record from the region, as well as geometric-kinematic, tectonic models of the possible deformation of northwest Okhotsk to try to better understand the different probabilities of how this slowly deforming plate boundary zone is behaving.

  18. Augmented reality: dé nieuwe dimensie in de sport?

    NARCIS (Netherlands)

    Slender, Hans

    2010-01-01

    Volgens trendwatcher Justien Marseille de trend van 2010: augmented reality. Augmented reality is een techniek om met de computer gemaakte beelden toe te voegen aan de realiteit. Het Nederlandse Layar (layar.com) presenteerde zich vorig jaar vol trots als een unieke augmented reality browser, met

  19. Assessment of comparative skills between hand-assisted and straight laparoscopic colorectal training on an augmented reality simulator.

    Science.gov (United States)

    Leblanc, F; Delaney, C P; Neary, P C; Rose, J; Augestad, K M; Senagore, A J; Ellis, C N; Champagne, B J

    2010-09-01

    The aim of this study was to compare skills sets during a hand-assisted and straight laparoscopic colectomy on an augmented reality simulator. Twenty-nine surgeons, assigned randomly in 2 groups, performed laparoscopic sigmoid colectomies on a simulator: group A (n = 15) performed hand-assisted then straight procedures; group B (n = 14) performed straight then hand-assisted procedures. Groups were compared according to prior laparoscopic colorectal experience, performance (time, instrument path length, and instrument velocity changes), technical skills, and operative error. Prior laparoscopic colorectal experience was similar in both groups. Both groups had better performances with the hand-assisted approach, although technical skill scores were similar between approaches. The error rate was higher with the hand-assisted approach in group A, but similar between both approaches in group B. These data define the metrics of performance for hand-assisted and straight laparoscopic colectomy on an augmented reality simulator. The improved scores with the hand-assisted approach suggest that with this simulator a hand-assisted model may be technically easier to perform, although it is associated with increased intraoperative errors.

  20. Mechanical Behavior of BFRP-Steel Composite Plate under Axial Tension

    Directory of Open Access Journals (Sweden)

    Yunyu Li

    2014-06-01

    Full Text Available Combining the advantages of basalt fiber-reinforced polymer (BFRP material and steel material, a novel BFRP-steel composite plate (BSP is proposed, where a steel plate is sandwiched between two outer BFRP laminates. The main purpose of this research is to investigate the mechanical behavior of the proposed BSP under uniaxial tension and cyclic tension. Four groups of BSP specimens with four different BFRP layers and one control group of steel plate specimens were prepared. A uniaxial tensile test and a cyclic tensile test were conducted to determine the initial elastic modulus, postyield stiffness, yield strength, ultimate bearing capacity and residual deformation. Test results indicated that the stress-strain curve of the BSP specimen was bilinear prior to the fracture of the outer BFRP, and the BSP specimen had stable postyield stiffness and small residual deformation after the yielding of the inner steel plate. The postyield modulus of BSP specimens increased almost linearly with the increasing number of outer BFRP layers, as well as the ultimate bearing capacity. Moreover, the predicted results from the selected models under both monotonic tension and cyclic tension were in good agreement with the experimental data.

  1. Risk of symptomatic heterotopic ossification following plate osteosynthesis in multiple trauma patients: an analysis in a level-1 trauma centre

    Directory of Open Access Journals (Sweden)

    Pape Hans-Christoph

    2009-10-01

    Full Text Available Abstract Background Symptomatic heterotopic ossification (HO in multiple trauma patients may lead to follow up surgery, furthermore the long-term outcome can be restricted. Knowledge of the effect of surgical treatment on formation of symptomatic heterotopic ossification in polytrauma is sparse. Therefore, we test the effects of surgical treatment (plate osteosynthesis or intramedullary nailing on the formation of heterotopic ossification in the multiple trauma patient. Methods We retrospectively analysed prospectively documented data of blunt multiple trauma patients with long bone fractures which were treated at our level-1 trauma centre between 1997 and 2005. Patients were distributed to 2 groups: Patients treated by intramedullary nails (group IMN or plate osteosynthesis (group PLATE were compared. The expression and extension of symptomatic heterotopic ossifications on 3-6 months follow-up x-rays in antero-posterior (ap and lateral views were classified radiologically and the maximum expansion was measured in millimeter (mm. Additionally, ventilation time, prophylactic medication like indomethacine and incidence and correlation of head injuries were analysed. Results 101 patients were included in our study, 79 men and 22 women. The fractures were treated by intramedullary nails (group IMN n = 50 or plate osteosynthesis (group PLATE n = 51. Significantly higher radiologic ossification classes were detected in group PLATE (2.9 ± 1.3 as compared to IMN (2.2 ± 1.1; p = 0.013. HO size in mm ap and lateral showed a tendency towards larger HOs in the PLATE group. Additionally PLATE group showed a higher rate of articular fractures (63% vs. 28% in IMN while IMN demonstrated a higher rate of diaphyseal fractures (72% vs. 37% in PLATE; p = 0.003. Ventilation time, indomethacine and incidence of head injuries showed no significant difference between groups. Conclusion Fracture care with plate osteosynthesis in polytrauma patients is associated with

  2. Augmented reality services

    Directory of Open Access Journals (Sweden)

    Tomáš Koubek

    2013-01-01

    Full Text Available We assume that one of the key reasons is in the difference between a standalone application and a web service. Both architectures have some advantages and disadvantages. The Standalone application (e.g. Nokia/OVI Maps provides the required functionality. From the user point of view, main asset of this “offline” approach is network connectivity independence. However, this kind of applications must be upgraded manually. Moreover, it is hard to get any data about the application usage because it requires additional actions from the user – data are usually acquired through conventional ways, such as email or web forms.The online service such as Google Maps (including its mobile application can offer the same functionality as the offline application. Nevertheless, a permanent connection to provider servers is necessary. This can be taken as a drawback. On the other hand, usage data collection is easier and can be done without the user intervention. The data collection provides a valuable analysis basis of the user habits and needs. This analysis is necessary for design of a complex “user” based solutions such as Google Now.Augmented reality applications are usually based on the first mentioned approach. In this article, we describe our model of augmented reality as a service and compare its features with standalone solutions. Further, other important key aspects for large emergence of augmented reality services in a mainstream market are discussed.

  3. Recent Development of Augmented Reality in Surgery: A Review

    Science.gov (United States)

    Vávra, P.; Zonča, P.; Ihnát, P.; El-Gendi, A.

    2017-01-01

    Introduction The development augmented reality devices allow physicians to incorporate data visualization into diagnostic and treatment procedures to improve work efficiency, safety, and cost and to enhance surgical training. However, the awareness of possibilities of augmented reality is generally low. This review evaluates whether augmented reality can presently improve the results of surgical procedures. Methods We performed a review of available literature dating from 2010 to November 2016 by searching PubMed and Scopus using the terms “augmented reality” and “surgery.” Results. The initial search yielded 808 studies. After removing duplicates and including only journal articles, a total of 417 studies were identified. By reading of abstracts, 91 relevant studies were chosen to be included. 11 references were gathered by cross-referencing. A total of 102 studies were included in this review. Conclusions The present literature suggest an increasing interest of surgeons regarding employing augmented reality into surgery leading to improved safety and efficacy of surgical procedures. Many studies showed that the performance of newly devised augmented reality systems is comparable to traditional techniques. However, several problems need to be addressed before augmented reality is implemented into the routine practice. PMID:29065604

  4. Recent Development of Augmented Reality in Surgery: A Review

    Directory of Open Access Journals (Sweden)

    P. Vávra

    2017-01-01

    Full Text Available Introduction. The development augmented reality devices allow physicians to incorporate data visualization into diagnostic and treatment procedures to improve work efficiency, safety, and cost and to enhance surgical training. However, the awareness of possibilities of augmented reality is generally low. This review evaluates whether augmented reality can presently improve the results of surgical procedures. Methods. We performed a review of available literature dating from 2010 to November 2016 by searching PubMed and Scopus using the terms “augmented reality” and “surgery.” Results. The initial search yielded 808 studies. After removing duplicates and including only journal articles, a total of 417 studies were identified. By reading of abstracts, 91 relevant studies were chosen to be included. 11 references were gathered by cross-referencing. A total of 102 studies were included in this review. Conclusions. The present literature suggest an increasing interest of surgeons regarding employing augmented reality into surgery leading to improved safety and efficacy of surgical procedures. Many studies showed that the performance of newly devised augmented reality systems is comparable to traditional techniques. However, several problems need to be addressed before augmented reality is implemented into the routine practice.

  5. A process for treatment of mixed waste containing chemical plating wastes

    International Nuclear Information System (INIS)

    Anast, K.R.; Dziewinski, J.; Lussiez, G.

    1995-01-01

    The Waste Treatment and Minimization Group at Los Alamos National Laboratory has designed and will be constructing a transportable treatment system to treat low-level radioactive mixed waste generated during plating operations. The chemical and plating waste treatment system is composed of two modules with six submodules, which can be trucked to user sites to treat a wide variety of aqueous waste solutions. The process is designed to remove the hazardous components from the waste stream, generating chemically benign, disposable liquids and solids with low level radioactivity. The chemical and plating waste treatment system is designed as a multifunctional process capable of treating several different types of wastes. At this time, the unit has been the designated treatment process for these wastes: Destruction of free cyanide and metal-cyanide complexes from spent plating solutions; destruction of ammonia in solution from spent plating solutions; reduction of Cr VI to Cr III from spent plating solutions, precipitation, solids separation, and immobilization; heavy metal precipitation from spent plating solutions, solids separation, and immobilization, and acid or base neutralization from unspecified solutions

  6. Effects of early augmentation of labour with amniotomy and oxytocin in nulliparous women: a meta-analysis.

    Science.gov (United States)

    Fraser, W; Vendittelli, F; Krauss, I; Bréart, G

    1998-02-01

    To estimate the effects among nulliparae of early augmentation with amniotomy and oxytocin on caesarean delivery, and on other indicators of maternal and neonatal morbidity including transfusion. Apgar score manual and computerised searches. Two unpublished studies were identified through direct communication with the investigators. Twelve trials were identified which compared a policy of early labour augmentation including amniotomy followed by oxytocin with a less active form of management. Two methodologically unacceptable studies were excluded. Studies were grouped according to whether they admitted only women with abnormal progress (therapy trials: n = 3) or accepted women with normal labour (prevention trials: n = 7). Unstratified analysis did not provide support for the hypothesis that early augmentation reduces the risk of caesarean section (typical odds ratio [OR] 0.9; 95% CI 0.7-1.1). The typical odds ratio for prevention trials was similar to that obtained in the unstratified analysis (typical OR 0.9, 95% CI 0.7-1.2). Although only a small number of women have been randomised in therapy trials, a trend toward a reduction in the rate of caesarean section with early intervention was seen in this group (typical OR 0.6, 95% CI 0.2-1.4). Early augmentation does not appear to provide benefit over a more conservative form of management in the context of care of nulliparous women with mild delays in the progress of labour. In the context of established delay in labour, an active policy of augmentation may reduce the risk of caesarean section. However, only three small trials have been performed in this context, and they do not have adequate power to allow firm conclusions to be drawn.

  7. Atypical antipsychotics as augmentation therapy in anorexia nervosa.

    Directory of Open Access Journals (Sweden)

    Enrica Marzola

    Full Text Available Anorexia nervosa (AN is a life-threatening and difficult to treat mental illness with the highest mortality rates of any psychiatric disorder. We aimed to garner preliminary data on the real-world use of olanzapine and aripiprazole as augmentation agents of Selective Serotonin Reuptake Inhibitors (SSRIs in adult inpatients affected by AN. We retrospectively evaluated the clinical charts of patients who were hospitalized between 2012 and 2014. Patients were evaluated upon admission and discharge. We investigated eating symptomatology, and both general and eating psychopathology using: Hamilton Rating Scale for Anxiety, Hamilton Rating Scale for Depression, and Yale-Brown-Cornell Eating Disorders Scale. The charts of 75 patients were included in this study. The sample resulted equally distributed among those receiving SSRIs and either aripiprazole or olanzapine in addition to SSRIs. Notwithstanding a few baseline clinical differences, upon discharge all groups were significantly improved on all measures. Interestingly, aripiprazole showed the greatest effectiveness in reducing eating-related preoccupations and rituals with a large effect size. The body of evidence on medication management in AN is in dismal condition. Augmentation therapy is a well-established approach to a variety of mental disorders and it is often used in every-day clinical practice with patients affected by AN as well. Nevertheless, to date very little data is available on this topic. Results from our sample yielded promising results on the effectiveness of aripiprazole augmentation in reducing eating-related obsessions and compulsions. Randomized controlled trials are warranted to confirm these encouraging findings.

  8. Augmented REality Sandtables (ARESs) Impact on Learning

    Science.gov (United States)

    2016-07-01

    ARL-CR-0803 ● JULY 2016 US Army Research Laboratory Augmented REality Sandtable’s (ARES’s) Impact on Learning by Tarah N......The use of augmented reality (AR) to supplement training tools, specifically sand tables, can produce highly effective systems at relatively low

  9. Finite element analysis of a solar collector plate using two plate geometries

    Directory of Open Access Journals (Sweden)

    Diego Manuel Medina Carril

    2016-09-01

    Full Text Available The thermal behavior of an absorber plate in a solar collector is investigated using finite element analysis. The thermal behavior and efficiency of two absorber plate geometries are studied, using a typical solar collector with a rectangular profile as reference, and a proposed absorber plate with curved geometry. An analysis of the most important parameters involved in the design of the absorber plate was carried out, indicating that the curved geometry of the absorber plate yields an average efficiency ~25% higher than the conventional rectangular geometry. The results suggest that a curved profile made of materials such as aluminum with thermal conductivity higher than 200W/m°C, plate thickness of the order of 2-3mm and with a large density of tubes per unit area of the collector´s plate greatly benefits the thermal efficiency of the solar collector.

  10. Virtual and augmented reality for training on maintenance

    International Nuclear Information System (INIS)

    Gonzalez, F.

    2001-01-01

    This paper presents two projects focused to support training on maintenance using new technologies. Both projects aims at specifying. designing, developing, and demonstrating prototypes allowing computer guided maintenance of complex mechanical elements using Virtual Reality (VIRMAN) and Augmented Reality (STARMATE) techniques. VIRMAN project is dedicated to training course development on maintenance using Virtual Reality. It based in the animation of three dimension images for component assembly/de-assembly or equipment movements. STARMATE will rely on Augmented Reality techniques which is a growing area in virtual Reality research. The idea of Augmented Reality is to combine a real scene, viewed by the user, with a virtual scene generated by a computer augmenting the reality with additional information. (Author)

  11. Post irradiation examinations on UMo full-sized plates - IRIS2 experiment

    International Nuclear Information System (INIS)

    Huet, F.; Noirot, J.; Marelle, V.; Dubois, S.; Boulcourt, P.; Sacristan, P.; Naury, S.; Lemoine, P.

    2005-01-01

    IRIS2 irradiation was the last irradiation of 4 full sized plates launched by CEA for the French UMo group to test in which operating conditions the coarse porosity forms in the UMo/Al interaction product. IRIS2 consists in four plates with high uranium loading and U-7wt%Mo atomised powder irradiated up to 60 days at OSIRIS reactor in IRIS device at a peak power of 238 W.cm -2 . The results show that in the tested conditions pillowing of the plate started from a fission density over 2.10 21 fission.cm -3 . Moreover, they show that the fission products and impurities have a key-role in the origin of the excessive plate swelling. (author)

  12. Handbook of solar energy data for south-facing surfaces in the United States. Volume I. An insolation, array shadowing, and reflector augmentation model

    Energy Technology Data Exchange (ETDEWEB)

    Smith, J.H.

    1980-01-15

    This handbook provides estimates of average available solar insolation to fixed, flat-plate, south-facing collector surfaces at various array tilt angles at numerous sites in the US. This first volume contains average daily, total insolation estimates, by month, and annual totals for 235 locations. A model that estimates the direct, diffuse, and reflected components of total insolation on an hourly, daily, and monthly basis is presented. A shadow loss model and a reflector augmentation model providing estimates of the losses and gains associated with various fixed array geometries are also described. These models can be used with the insolation model provided or with other recorded data. A FORTRAN computer program with user's guide is presented. The program can be used to generate additional handbook values or to examine the effects of array shadowing and fixed reflector augmentation effects on a daily, monthly, or annual basis. Array shadowing depends on location, array size, array tilt, array separation, and time. The program can be used to examine trade-offs between array spacing and insolation losses due to shadowing. The reflector augmentation program can be used to examine trade-offs among array size and tilt, separation, and reflector tilt to determine the combination of design values that optimize the economic objectives or technical criteria of the system.

  13. ARVIKA - Augmented Reality in Entwicklung, Produktion und Service: Anbindung eines mobilen Augmented Reality Systems an eine stationäre Infrastruktur. Schlussbericht

    OpenAIRE

    Wichert, R.; Balfanz, D.

    2003-01-01

    ARVIKA uses augmented reality (AR) technologies to research and create a user-oriented and system-driven support of operation procedures. It focuses on the development, production, and service of complex technical products and systems. Augmented-reality technologies improve working environments by merging real objects with computer-generated virtual objects to allow for detailed engineering and processing instructions. Augmented reality is a novel approach to the interaction between human and...

  14. [Locked plating with minimally invasive percutaneous plate osteosynthesis versus intramedullary nailing of distal extra-articular tibial fracture: a retrospective study].

    Science.gov (United States)

    Yao, Qi; Ni, Jie; Peng, Li-bin; Yu, Da-xin; Yuan, Xiao-ming

    2013-12-17

    To compare the efficacies of minimally invasive plate osteosynthesis (MIPPO) and interlocking intramedullary nailing (IMN) in the treatment of extra-articular fractures of distal tibia. Retrospective reviews were conducted for 126 patients with extra-articular distal tibia fractures. Treatment was either MIPPO (n = 61) or IMN (n = 65). The outcomes were assessed by comparing operating duration, time to union, the last follow-up American Orthopedic Foot and Ankle Society (AOFAS) score and complication rate. The average follow-up period was 23.7 (12-53) months. In the minimally invasive plate osteosynthesis group, there were deep infections (n = 2), superficial infections (n = 5), delayed union (n = 2), malunion (n = 2) and knee joint pain (n = 10) were observed. In addition, the average operating duration (85.9 ± 18.9 min), average time to union (17.3 ± 3.8 weeks) and average AOFAS (83.2 ± 11.9) were analyzed. In the interlocking intramedullary nailing group, there were delayed union (n = 3), malunion (n = 12) and knee joint pain (n = 22). And the average operating duration (83.3 ± 15.7 min), average time to union (16.5 ± 3.1 weeks) and average AOFAS (84.9 ± 12.0) were analyzed. No statistical significance existed in operating duration, time to union and the last follow-up AOFAS between two groups (P > 0.05). However, the rates of malformation and knee joint pain were higher in the intramedullary nail group than those in the plate group. And the difference was statistically significant (P = 0.015, P = 0.025). Both MIPPO and IMN are effective for extra-articular fractures of distal tibia. However, the former has the advantage of lowers rate of malformation and knee joint pain. Therefore a surgeon should consider the degree of injury while managing extra-articular fracture of distal tibia.

  15. A New Type of Inscribed Copper Plate from Indus Valley (Harappan Civilisation

    Directory of Open Access Journals (Sweden)

    Vasant Shinde

    2014-10-01

    Full Text Available A group of nine Indus Valley copper plates (c. 2600–2000 BC, discovered from private collections in Pakistan, appear to be of an important type not previously described. The plates are significantly larger and more robust than those comprising the corpus of known copper plates or tablets, and most significantly differ in being inscribed with mirrored characters. One of the plates bears 34 characters, which is the longest known single Indus script inscription. Examination of the plates with x-ray fluorescence (XRF spectrophotometry indicates metal compositions, including arsenical copper, consistent with Indus Valley technology. Microscopy of the metal surface and internal structure reveals detail such as pitting, microcrystalline structure, and corrosion, consistent with ancient cast copper artifacts. Given the relative fineness of the engraving, it is hypothesised that the copper plates were not used as seals, but have characteristics consistent with use in copper plate printing. As such, it is possible that these copper plates are by far the earliest known printing devices, being at least 4000 years old.

  16. Guidelines for user interactions in mobile augmented reality

    OpenAIRE

    Ortman, Erik; Swedlund, Kenneth

    2012-01-01

    Over the last couple of years the field of Augmented Reality has transformed from something mainly seen in academic researchinto several examples of big commercially successful products, and the widespread use of highly capable mobile devices has greatly helped accelerate this trend. The powerful sensors in modern handsets enable designers to bring Augmented Reality implementations to the hands ofthe users.This thesis examines how Augmented Reality can be implemented onmobile platforms, mainl...

  17. An experimental test of alternative population augmentation scenarios.

    Science.gov (United States)

    Kronenberger, John A; Gerberich, Jill C; Fitzpatrick, Sarah W; Broder, E Dale; Angeloni, Lisa M; Funk, W Chris

    2018-01-19

    Human land use is fragmenting habitats worldwide and inhibiting dispersal among previously connected populations of organisms, often leading to inbreeding depression and reduced evolutionary potential in the face of rapid environmental change. To combat this augmentation of isolated populations with immigrants is sometimes used to facilitate demographic and genetic rescue. Augmentation with immigrants that are genetically and adaptively similar to the target population effectively increases population fitness, but if immigrants are very genetically or adaptively divergent, augmentation can lead to outbreeding depression. Despite well-cited guidelines for the best practice selection of immigrant sources, often only highly divergent populations remain, and experimental tests of these riskier augmentation scenarios are essentially nonexistent. We conducted a mesocosm experiment with Trinidadian guppies (Poecilia reticulata) to test the multigenerational demographic and genetic effects of augmenting 2 target populations with 3 types of divergent immigrants. We found no evidence of demographic rescue, but we did observe genetic rescue in one population. Divergent immigrant treatments tended to maintain greater genetic diversity, abundance, and hybrid fitness than controls that received immigrants from the source used to seed the mesocosms. In the second population, divergent immigrants had a slightly negative effect in one treatment, and the benefits of augmentation were less apparent overall, likely because this population started with higher genetic diversity and a lower reproductive rate that limited genetic admixture. Our results add to a growing consensus that gene flow can increase population fitness even when immigrants are more highly divergent and may help reduce uncertainty about the use of augmentation in conservation. © 2018 Society for Conservation Biology.

  18. Augmentation of the hard palate thin masticatory mucosa in the potential connective tissue donor sites using two collagen materials-Clinical and histological comparison.

    Science.gov (United States)

    Bednarz, Wojciech; Kobierzycki, Christopher; Dzięgiel, Piotr; Botzenhart, Ute; Gedrange, Tomasz; Ziętek, Marek

    2016-11-01

    Due to the similarity of keratinized gingival and palatal mucosa the latter can pose as a potential donor site for gingival recession coverage. However, its availability is restricted and a thin transplant bears the risk of being rejected. The aim of the present study was to compare the clinical and histological results of thin palatal mucosa augmentation, using lyophilized Biokol ® xenogenous collagen sponge and a suspension of xenogenous Gel 0 ® pure collagen with non-augmented tissue from the same patients. Ten patients simultaneously underwent bilateral augmentation procedures using Biokol ® and Gel 0 ® collagen material. The donor sites were augmented 8 weeks prior to the harvesting of the connective tissue graft (CTG) for the gingival recession coverage procedures. Prior to the implantation of the collagen material and during the course of harvesting the augmented CTG, tissue specimens were taken for histological examination. Prior to the commencement of the study and after it, the parameters of palatal gingival thickness at 4mm (PGT1), and at 8mm apical to the gingival margin (PGT2) around the teeth neighboring the operating fields were determined. In both groups the palatal mucosa had thickened significantly in both measuring sites. An intergroup comparison revealed greater thickening of the masticatory mucosa in the Biokol ® group at both measuring points. The histological image of the grafts, obtained from sites augmented using both test methods, revealed a typical pattern of mature fibrous connective tissue. No epithelial cells were found. Augmentation of thin masticatory mucosa using Biokol ® or Gel 0 ® collagen materials resulted in a significant thickening of the mucosa, which could be demonstrated to be greater in the first group. Copyright © 2016 Elsevier GmbH. All rights reserved.

  19. Radiographic Comparison of Bovine Bone Substitute Alone versus Bovine Bone Substitute and Simvastatin for Human Maxillary Sinus Augmentation

    Directory of Open Access Journals (Sweden)

    Amir Ali Reza Rasouli Ghahroudi

    2018-01-01

    Full Text Available Objectives: The aim of this study was to compare the efficacy of bovine bone substitute (Compact Bone B. ® alone versus bovine bone substitute and simvastatin for human maxillary sinus augmentation.Materials and Methods: This study was conducted on 16 sinuses in eight patients. Radiographic assessments were done preoperatively (T0, immediately (T1 and at nine months after sinus grafting (T2. Alveolar bone height and density were assessed on cone beam computed tomography (CBCT scans using Planmeca Romexis™ Imaging Software 2.2.Results: The change in alveolar bone height and density between T0, T1 and T2 was significant in both groups. Alveolar bone height (h0, h1, h2 and vertical height of the grafted bone (g1, g2 in three lines (anterior, middle and posterior were not significantly different between groups. The grafted bone height shrinkage (% in the anterior, middle and posterior limits of the augmented area were not significantly different between groups. The existing alveolar and grafted bone density increased significantly in both groups between T1 and T2, except for the existing alveolar bone density in the control group. There were no statistically significant differences between the alveolar bone density values obtained in TI and T2 between groups, except for the existing alveolar bone density at T1.Conclusions: This study did not show any significant positive effect for simvastatin in maxillary sinus augmentation based on radiographic examination.

  20. Augmented reality for industrial robot programmers: Workload analysis for task-based, augmented reality-supported robot control

    OpenAIRE

    Stadler, S.; Kain, K.; Giuliani, M.; Mirnig, N.; Stollnberger, G.; Tscheligi, M. ed

    2016-01-01

    Augmented reality (AR) can serve as a tool to provide helpful information in a direct way to industrial robot programmers throughout the teaching process. It seems obvious that AR support eases the programming process and increases the programmer's productivity and programming accuracy. However, additional information can also potentially increase the programmer's perceived workload. To explore the impact of augmented reality on robot teaching, as a first step we have chosen a Sphero robot co...

  1. Who’s That Girl? Handheld Augmented Reality for Printed Photo Books

    OpenAIRE

    Henze , Niels; Boll , Susanne

    2011-01-01

    Part 1: Long and Short Papers; International audience; Augmented reality on mobile phones has recently made major progress. Lightweight, markerless object recognition and tracking makes handheld Augmented Reality feasible for new application domains. As this field is technology driven the interface design has mostly been neglected. In this paper we investigate visualization techniques for augmenting printed documents using handheld Augmented Reality. We selected the augmentation of printed ph...

  2. Lamb wave band gaps in a double-sided phononic plate

    Science.gov (United States)

    Wang, Peng; Chen, Tian-Ning; Yu, Kun-Peng; Wang, Xiao-Peng

    2013-02-01

    In this paper, we report on the theoretical investigation of the propagation characteristics of Lamb wave in a phononic crystal structure constituted by a square array of cylindrical stubs deposited on both sides of a thin homogeneous plate. The dispersion relations, the power transmission spectra, and the displacement fields of the eigenmodes are studied by using the finite-element method. We investigate the evolution of band gaps in the double-sided phononic plate with stub height on both sides arranged from an asymmetrical distribution to a symmetrical distribution gradually. Numerical results show that as the double stubs in a unit cell arranged more symmetrically on both sides, band width shifts, new band gaps appear, and the bands become flat due to localized resonant modes which couple with plate modes. Specially, more band gaps and flat bands can be found in the symmetrical system as a result of local resonances of the stubs which interact in a stronger way with the plate modes. Moreover, the symmetrical double-sided plate exhibits lower and smaller band gap than that of the asymmetrical plate. These propagation properties of elastic or acoustic waves in the double-sided plate can potentially be utilized to generate filters, slow the group velocity, low-frequency sound insulation, and design acoustic sensors.

  3. Bending and stretching of plates

    CERN Document Server

    Mansfield, E H; Hemp, W S

    1964-01-01

    The Bending and Stretching of Plates deals with elastic plate theory, particularly on small- and large-deflexion theory. Small-deflexion theory concerns derivation of basic equations, rectangular plates, plates of various shapes, plates whose boundaries are amenable to conformal transformation, plates with variable rigidity, and approximate methods. Large-deflexion theory includes general equations and some exact solutions, approximate methods in large-deflexion theory, asymptotic large-deflexion theories for very thin plates. Asymptotic theories covers membrane theory, tension field theory, a

  4. Achieving a predictable 24-hour return to normal activities after breast augmentation: part II. Patient preparation, refined surgical techniques, and instrumentation.

    Science.gov (United States)

    Tebbetts, John B

    2006-12-01

    The goal of this study was to develop practices that would allow patients undergoing subpectoral augmentation to predictably return to full normal activities within 24 hours after the operation, free of postoperative adjuncts. Part I of this study used motion and time study principles to reduce operative times, medication dosages, perioperative morbidity, and recovery times in augmentation mammaplasty. Part II of the study focuses on details of patient education, preoperative planning, instrumentation, and surgical technique modifications that were identified, modified, and implemented to achieve the results reported in part I. Two groups of 16 patients each (groups 1 and 2) were studied retrospectively for comparison to a third group of 627 patients (group 3) studied prospectively. Patients in group 1 had axillary partial retropectoral breast augmentations in 1982-1983, using dissociative anesthesia, blunt instrument implant pocket dissection, and Dow Corning, double-lumen implants containing 20 mg of methylprednisolone and 20 cc of saline in the outer lumen of the implants. Patients in group 2 (1990) had inframammary, retromammary augmentations by using a combination of blunt and electrocautery dissection, Surgitek Replicon polyurethane-covered, silicone gel-filled implants, and general endotracheal anesthesia. Patients in group 3 (1998 to 2001, n = 627) had inframammary partial retropectoral, inframammary retromammary, and axillary partial retropectoral augmentations under general endotracheal anesthesia. Refined practices and surgical techniques from studies of groups 1 and 2 were applied in group 3. Videotapes from operative procedures of groups 1 and 2 were analyzed with macromotion and micromotion study principles, and tables of events were formulated for each move during the operation for all personnel in the operating room. Extensive details of surgical technique were examined and reexamined in 13 different stages by using principles of motion and time

  5. Bone Augmentation in Rabbit Tibia Using Microfixed Cobalt-Chromium Membranes with Whole Blood and Platelet-Rich Plasma

    Directory of Open Access Journals (Sweden)

    Oscar A. Decco

    2015-07-01

    Full Text Available Background: Bone augmentation is a subject of intensive investigation in regenerative bone medicine and constitutes a clinical situation in which autogenous bone grafts or synthetic materials are used to aid new bone formation. Method: Based on a non-critical defect, Co-Cr barrier membranes were placed on six adult Fauve de Bourgogne rabbits, divided into two groups: whole blood and PRP. Three densitometric controls were performed during the experiment. The animals were euthanized at 30, 45, 60, and 110 days. The presence of newly formed bone was observed. Samples for histological studies were taken from the augmentation center. Results: External and internal bone tissue augmentation was observed in almost all cases. Significant differences between PRP- and whole blood–stimulated bone augmentation were not observed. At 60 days, bones with PRP presented higher angiogenesis, which may indicate more proliferation and cellular activity. Conclusion: PRP activates the bone regeneration process under optimized conditions by stimulation of osteoblast proliferation after six weeks, when a significant difference in cellular activity was observed. Membranes could stimulate bone augmentation at the site of placement and in the surrounding areas.

  6. Towards an interactive medical system by augmented reality

    OpenAIRE

    Khawla Ben Abderrahim; Mohamed Kallel; M.S. Bouhlel

    2013-01-01

    Augmented reality is a computer field that progresses rapidly. Its principle is to mix the real world and the virtual world. Many applications already use augmented reality, particularly the medical field. Medical image allows doctors to make diagnosis of the patient. This diagnosis allows him to make the best decision without committing professional mistakes that can cause problems. Hence the idea of integrating augmented reality with medical image analysis to help the doctor to make the bes...

  7. Giardia muris and Giardia duodenalis groups: ultrastructural differences between the trophozoites.

    Science.gov (United States)

    Sogayar, M I; Gregório, E A

    1989-01-01

    Trophozoites of the Giardia muris group from hamsters, domestic rats and mice and of the Giardia duodenalis group from hamsters and domestic rats were examined by transmission electron microscopy. The basic ultrastructure of the trophozoites was similar. Differences were shown in the morphology of the ventrolateral flange of the trophozoites of Giardia muris and Giardia duodenalis groups. Marginal plates are less developed in the species of the Giardia duodenalis group. In this group, the distal extremity of the lateral flange is short and thick and the marginal plate does not penetrate into the distal extremity of the flange. In the Giardia muris group, the ventro-lateral flange is well developed and narrow and the marginal plate penetrates the distal extremity of the flange. The osmiophilic lamella, which accompanies the dorsal surface of the marginal plate is seen only in the Giardia muris group.

  8. Highly porous hydroxyapatite with and without local harvested bone in sinus floor augmentation: a histometric study in pigs.

    Science.gov (United States)

    Möller, Björn; Acil, Yahya; Birkenfeld, Falk; Behrens, Eleonore; Terheyden, Hendrik; Wiltfang, Jörg

    2014-07-01

    Sinus floor augmentation with autologous bone is an accepted treatment option in dental implantology. In this study, an entirely synthetic, nano-structured, hydroxyapatite-based bone substitute material (SBSM, NanoBone(®); Artoss, Rostock, Germany) was supplemented with a mixture of locally harvested bone to enhance osteogenesis. Bilateral sinus augmentation procedures were performed in eight domestic pigs using the lateral window technique. On the right side (control), 2.6 ml of SBSM was used, and on the left side (test), 2.6 ml of SBSM with additional 15% (390 μl) autologous bone was used. At the time of augmentation, a titanium implant (ITI(®)) was inserted from a laterocaudal direction. After 3 months, the sites of augmentation were removed and examined in non-decalcified sections by microradiography and fluorescence microscopy of sequentially labelled specimens and histometry. On both sides, a significant amount of newly formed bone was observed. However, a statistically significant difference in the bone-implant contact was observed in the control group (median, 28.9%) compared with the test side with the additional autologous bone (median, 40.6%) (P = 0.01). Different bone density was achieved from the coronal to apical surfaces (medians, 54.6%, 9.6%, and 27.5%) compared with the test side (medians, 55.2%, 40.6%, and 44.2%). The median of augmentation height was 8.6 mm on the control side and 11.5 mm on the test side (P = 0.01). Bone apposition was observed in both groups after 15 days. The SBSM shows acceptable results in sinus floor augmentation. The additional use of locally harvested autologous bone enhances bone density and osseointegration of the implants. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  9. Segmental Mirroring: Does It Eliminate the Need for Intraoperative Readjustment of the Virtually Pre-Bent Reconstruction Plates and Is It Economically Valuable?

    Science.gov (United States)

    Khalifa, Ghada Amin; Abd El Moniem, Nahed Adly; Elsayed, Shadia Abd-ElHameed; Qadry, Yara

    2016-03-01

    The aim of this study was to compare segmental mirroring with mirroring of the entire unaffected side to determine which method obviates intraoperative readjustment of virtually planned pre-bent plates and to evaluate the effect on costs. Patients eligible for inclusion in this prospective study had unilateral mandibular discontinuity defects. Patients were randomly divided into 2 groups. In group I, models were constructed by mirroring the entire unaffected side of the mandible at the midsagittal plane. In group II, only the resected segments were cut and replaced by the corresponding mirrored healthy segments. The lesions were resected, and their sites were reconstructed using pre-bent reconstruction plates. The need for intraoperative plate readjustment, plate placement time, operation time, and operation costs were reviewed. Fifty patients were enrolled in this study. All but 5 plates in group I required readjustment. In group II, plates were placed without intraoperative handling. Average operating times were 4.20 ± 0.56 hours in group I and 3.186 ± 0.28 hours in group II (P = .00002). Mean times for plate placement were 33.36 ± 8.20 and 21.88 ± 5.73 minutes in groups I and II, respectively. The difference resulted in an average time gain of 11.48 minutes. Average personal costs per minute were US$740.77 for group I and US$560.87 for group II. The difference resulted in an average saving of approximately US$179.90. Segmental mirroring is superior in reflecting the bone anatomy in 3-dimensional models, thus eliminating intraoperative plate readjustment and providing better plate adaptation with better contour. It decreases operating time and costs and thus can be recommended for lesions that do not cross the midline. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  10. [Display technologies for augmented reality in medical applications].

    Science.gov (United States)

    Eck, Ulrich; Winkler, Alexander

    2018-04-01

    One of the main challenges for modern surgery is the effective use of the many available imaging modalities and diagnostic methods. Augmented reality systems can be used in the future to blend patient and planning information into the view of surgeons, which can improve the efficiency and safety of interventions. In this article we present five visualization methods to integrate augmented reality displays into medical procedures and the advantages and disadvantages are explained. Based on an extensive literature review the various existing approaches for integration of augmented reality displays into medical procedures are divided into five categories and the most important research results for each approach are presented. A large number of mixed and augmented reality solutions for medical interventions have been developed as research prototypes; however, only very few systems have been tested on patients. In order to integrate mixed and augmented reality displays into medical practice, highly specialized solutions need to be developed. Such systems must comply with the requirements with respect to accuracy, fidelity, ergonomics and seamless integration into the surgical workflow.

  11. Sentinel lymph node detection after transaxillary augmentation mammoplasty: a prospective controlled study utilizing lymphoscintigraphy in 43 breasts

    International Nuclear Information System (INIS)

    Sado, Heitor Naoki; Yamada, Airton Seiji; Graf, Ruth Maria; Timi, Jorge Rufino Ribas; Matias, Jorge Eduardo Fouto; Urban, Cicero Andrade; Woellner, Luiz Carlos; Ferreira, Eduardo de Castro

    2008-01-01

    Objective: To evaluate the potential influence of transaxillary augmentation mammoplasty on future detection of sentinel lymph node. Materials and methods: Prospective controlled study where 22 patients were selected and divided into two groups (post-mammoplasty and control) corresponding to 43 breasts (22 in the post-mammoplasty group and 21 in the control group) evaluated by lymphoscintigraphy immediately after periareolar 99m Tc-phytate injections. In the statistical analysis, p values < 0.05 were considered as significant. Results: All the breasts in the post-mammoplasty group presented lymphatic drainage to the axillary chain, with no difference as compared with the control group (p 0.488). The average number of hot lymph nodes was 1.27 ± 0.46 in the post-mammoplasty group, and 1.33 ± 0.58 in the control group (p = 0.895). The mean time required to visualize the first lymph node was 3.14 ± 4.42 minutes in the post mammoplasty group, and 5.48 ± 5.06 minutes in the control group (p 0.136). Conclusion: Transaxillary augmentation mammoplasty did not affect the future detection of sentinel lymph node. (author)

  12. Analytical investigation of third grade nanofluidic flow over a riga plate using Cattaneo-Christov model

    Science.gov (United States)

    Naseem, Anum; Shafiq, Anum; Zhao, Lifeng; Farooq, M. U.

    2018-06-01

    This article addresses third grade nanofluidic flow instigated by riga plate and Cattaneo-Christov theory is adopted to investigate thermal and mass diffusions with the incorporation of newly eminent zero nanoparticles mass flux condition. The governing system of equations is nondimensionalized through relevant similarity transformations and significatory findings are attained by using optimal homotopy analysis method. The behaviors of affecting parameters for velocity, temperature and concentration profiles are depicted graphically and also verified through three dimensional patterns for some parameters. Values of skin friction coefficient and Nusselt number with the apposite discussion have been recorded. The current results reveal that temperature and concentration profiles experience decline when thermal and concentration relaxation parameters are augmented respectively.

  13. Virtual study groups and online Observed Structured Clinical Examinations practices - enabling trainees to enable themselves.

    Science.gov (United States)

    Davidson, Dennisa; Evans, Lois

    2018-03-01

    To explore online study groups as augmentation tools in preparing for the Royal Australian and New Zealand College of Psychiatrists Observed Structured Clinical Examinations (OSCE) for fellowship. An online survey of New Zealand trainees was carried out to assess exam preparedness and openness to virtual study groups and results analysed. Relevant material around virtual study groups for fellowship examinations was reviewed and used to inform a pilot virtual study group. Four New Zealand trainees took part in the pilot project, looking at using a virtual platform to augment OSCE preparation. Of the 50 respondents 36% felt adequately prepared for the OSCE. Sixty-four per cent were interested in using a virtual platform to augment their study. Virtual study groups were noted to be especially important for rural trainees, none of whom felt able to form study groups for themselves. The pilot virtual study group was trialled successfully. All four trainees reported the experience as subjectively beneficial to their examination preparation. Virtual platforms hold promise as an augmentation strategy for exam preparation, especially for rural trainees who are more geographically isolated and less likely to have peers preparing for the same examinations.

  14. Percutaneous sacroiliac screw versus anterior plating for sacroiliac joint disruption: A retrospective cohort study.

    Science.gov (United States)

    Zhang, Ruipeng; Yin, Yingchao; Li, Shilun; Hou, Zhiyong; Jin, Lin; Zhang, Yingze

    2018-02-01

    Sacroiliac joint disruption (SJD) is a common cause of pelvic ring instability. Clinically, percutaneous unilateral S1 sacroiliac screw and anterior plating are always applied to manage SJD. The objective of this study is to elaborate their respective therapeutic traits. Patients with SJD fixed with unilateral S1 sacroiliac screw or anterior plating from June 2011 to June 2015 were recruited into this study and were divided into two groups: group A (unilateral sacroiliac screw) and group B (anterior plating). Surgical time, blood loss, frequency of intraoperative fluoroscopy and complications were reviewed. Postoperative radiograph and CT were conducted to assess the reduction quality. Fracture healing was evaluated by radiograph performed at each follow-up. Majeed score was recorded at the final follow-up to assess the functional outcome. Thirty-eight patients were included in group A and thirty-two patients in group B in this study. There was no significant difference in the demographic data of the two groups. A significant difference existed in the results for average operation time (P = .022) and blood loss (P = .000) between group A and group B. The mean frequency of intraoperative fluoroscopy was 15.82 in group A and 3.94 in group B (P = .000). All the fractures healed in this study. The rates of satisfactory reduction quality and functional outcome showed no significant difference between the two groups (P > .05). The complication rate was 15.79% (6/38) in group A and 9.38% (3/32) in group B (P = .660). Compared with anterior plating, percutaneous unilateral S1 sacroiliac screw usage is less invasive; however, more intraoperative X-ray exposure and permanent neurologic damage may accompany this procedure. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  15. Determination of student opinions in augmented reality

    Directory of Open Access Journals (Sweden)

    Huseyin Bicen

    2016-11-01

    Full Text Available The rapid development of the new technology has changed classroom teaching methods and tools in a positive way. This study investigated the classroom learning with augmented reality and the impact of student opinions. 97 volunteer undergraduate students took part in this study. Results included data in the form of frequencies, percentages and descriptive statistics. The results show that, with gamification methods, augmented reality content affected students’ opinions in a positive way. When QR codes are used in the classroom, students feel independent from classroom materials and can access various resources. Moreover, students think that, when augmented reality in the classroom is used, education is more enjoyable.

  16. Normative Data for Interpreting the BREAST-Q: Augmentation

    Science.gov (United States)

    Mundy, Lily R.; Homa, Karen; Klassen, Anne F.; Pusic, Andrea L.; Kerrigan, Carolyn L.

    2016-01-01

    Background The BREAST-Q is a rigorously developed, well-validated, patient-reported outcome (PRO) instrument with a module designed for evaluating breast augmentation outcomes. However, there are no published normative BREAST-Q scores, limiting interpretation. Methods Normative data were generated for the BREAST-Q Augmentation Module via the Army of Women (AOW), an online community of women (with and without breast cancer) engaged in breast-cancer related research. Members were recruited via email, with women 18 years or older without a history of breast cancer or breast surgery invited to participate. Descriptive statistics and a linear multivariate regression were performed. A separate analysis compared normative scores to findings from previously published BREAST-Q augmentation studies. Results The preoperative BREAST-Q Augmentation Module was completed by 1,211 women. Mean age was 54 ±24 years, mean body mass index (BMI) was 27 ±6, and 39% (n=467) had a bra cup size ≥D. Mean scores were Satisfaction with Breasts (54 ±19), Psychosocial Well-being (66 ±20), Sexual Well-being (49 ±20), and Physical Well-being (86 ±15). Women with a BMI of 30 or greater and bra cup size D or greater had lower scores. In comparison to AOW scores, published BREAST-Q augmentation scores were lower before and higher after surgery for all scales except Physical Well-being. Conclusions The AOW normative data represent breast-related satisfaction and well-being in woman not actively seeking breast augmentation. This data may be used as normative comparison values for those seeking and undergoing surgery as we did, demonstrating the value of breast augmentation in this patient population. PMID:28350657

  17. Three-Dimensional Volumetric Changes in Severely Resorbed Alveolar Sockets After Ridge Augmentation with Bovine-Derived Xenograft and Resorbable Barrier: A Preliminary Study on CBCT Imaging.

    Science.gov (United States)

    Manavella, Valeria; Romano, Federica; Corano, Lisa; Bignardi, Cristina; Aimetti, Mario

    The primary aim of the study was to describe a novel technique to evaluate volumetric hard tissue dimensional changes after ridge augmentation procedures. The secondary aim was to apply this newly developed measuring method to compromised alveolar sockets grafted with a slowly resorbing biomaterial covered with a collagen membrane. Eleven patients (6 men and 5 women, mean age 52.7 ± 8.3 years) requiring extraction of one hopeless tooth for severe periodontitis in the maxillary anterior area were consecutively treated with a ridge augmentation procedure. All experimental sockets showed advanced buccal bone plate deficiency and were grafted with deproteinized bovine bone mineral with 10% collagen covered with a collagen membrane. Sockets healed by secondary intention. Three-dimensional volumetric alveolar bone changes were calculated by superimposing cone beam computed tomography scans obtained before and 12 months after the augmentation procedure. After 12 months, the alveolar mineralized tissue filled 91.20% ± 7.96% of the maximum volume for regeneration. The augmentation procedure appeared not only to compensate for bone remodeling in most alveolar regions but also to repair a significant portion of the buccal wall. The most significant ridge width changes occurred 1 mm apical to the bone crest (2.33 ± 1.46 mm, P socket volume. A ridge preservation technique performed with collagenated bovine bone and a collagen membrane was able to improve ridge shape and dimensions in compromised alveolar sockets.

  18. Perceptions of women and men as entrepreneurs: evidence for differential effects of attributional augmenting.

    Science.gov (United States)

    Baron, R A; Markman, G D; Hirsa, A

    2001-10-01

    It was hypothesized that perceptions of women who become entrepreneurs are enhanced by attributional augmenting because they adopt this role despite major obstacles to doing so. In contrast, attributional augmenting was expected to operate to a lesser degree for men who become entrepreneurs because they presumably face weaker obstacles. Three studies offered support for these hypotheses; all of these investigations used between-subjects designs in which women and men shown in standard-format photos were described to different groups of raters as being either entrepreneurs or managers. As predicted, raters assigned significantly higher scores to women, but not to men, when they were described as entrepreneurs.

  19. Immediately loaded zygomatic implants vs conventional dental implants in augmented atrophic maxillae: 4 months post-loading results from a multicentre randomised controlled trial.

    Science.gov (United States)

    Esposito, Marco; Davó, Rubén; Marti-Pages, Carlos; Ferrer-Fuertes, Ada; Barausse, Carlo; Pistilli, Roberto; Ippolito, Daniela Rita; Felice, Pietro

    2018-01-01

    To compare the clinical outcome of immediately loaded cross-arch maxillary prostheses supported by zygomatic implants vs conventional implants placed in augmented bone. A total of 71 edentulous patients with severely atrophic maxillas, who did not have sufficient bone volume to place dental implants or when it was possible to place only two implants in the front area (minimal diameter 3.5 mm and length of 8 mm) and less than 4.0 mm of bone height subantrally, were randomised according to a parallel group design. They (35 patients) received zygomatic implants to be loaded immediately vs grafting with a xenograft, followed, after 6 months of graft consolidation, by the placement of six to eight conventional dental implants, submerged for 4 months (36 patients). To be loaded immediately, zygomatic implants had to be inserted with an insertion torque superior to 40 Ncm. Screw-retained, metal-reinforced, acrylic provisional prostheses were provided to be replaced by definitive Procera Implant Bridge Titanium prostheses (Nobel Biocare, Göteborg, Sweden) with ceramic or acrylic veneer materials 4 months after initial loading. Outcome measures were: prosthesis, implant and augmentation failures, any complications, quality of life (OHIP-14), the number of days that patients experienced total or partial impaired activity, time to function, and number of dental visits, assessed by independent assessors. Patients were followed up to 4 months after loading. No augmentation procedure failed. Three patients dropped out from the augmentation group. Six prostheses could not be delivered or failed in the augmentation group vs one prosthesis in the zygomatic group, the difference being statistically significant (difference in proportions = 15.32%; P = 0.04; 95% CI: 0.23 to 31.7). Eight patients lost 35 implants in the augmentation group vs three implants in one patient from the zygomatic group, the difference being statistically significant (difference in proportions = 21.38%; P = 0

  20. [Association between oxytocin augmentation intervals and the risk of postpartum haemorrhage].

    Science.gov (United States)

    Loscul, C; Chantry, A-A; Caubit, L; Deneux-Tharaux, C; Goffinet, F; Le Ray, C

    2016-09-01

    To study the association between the duration of oxytocin augmentation intervals and the risk of postpartum haemorrhage (PPH) among primiparous women in spontaneous labour. Retrospective cohort including primiparous women in spontaneous labour who received oxytocin during labour (n=454). Oxytocin augmentation intervals were dichotomized in intervalsoxytocin augmentation intervals. The association between oxytocin augmentation intervals and PPH was analyzed using univariate and multivariate analysis. Oxytocin augmentation intervals were shorter than 20minutes for 43.8% of the study population. The rate of PPH was higher (9.1% vs 3.5%; P=0.014), and the use of sulprostone was more frequent (6.5% vs 3.5%; P=0.013) if oxytocin augmentation intervals were shorter than 20minutes in comparison with intervals≥20minutes. The association between oxytocin augmentation intervals and PPH remains significant after adjustment on other PPH risk factors (adjusted OR=3.48, 95% CI [1.45-8.34]). The rate of adverse neonatal issue, defined by arterial pH at birth≤7.10 and/or 5minutes score d'Apgar≤7, was higher if oxytocin augmentation intervals wereoxytocin with augmentation intervals shorter than 20minutes. Copyright © 2016. Published by Elsevier Masson SAS.

  1. Spatial augmented reality merging real and virtual worlds

    CERN Document Server

    Bimber, Oliver

    2005-01-01

    Like virtual reality, augmented reality is becoming an emerging platform in new application areas for museums, edutainment, home entertainment, research, industry, and the art communities using novel approaches which have taken augmented reality beyond traditional eye-worn or hand-held displays. In this book, the authors discuss spatial augmented reality approaches that exploit optical elements, video projectors, holograms, radio frequency tags, and tracking technology, as well as interactive rendering algorithms and calibration techniques in order to embed synthetic supplements into the real

  2. Student Opinions on Mobile Augmented Reality Application and Developed Content in Science Class

    Directory of Open Access Journals (Sweden)

    Damla Karagozlu

    2017-11-01

    Full Text Available As one of the most important branches of science, natural science studies have never lost their currency. The purpose of this study is to examine the development process of Augmented Reality contents which were developed using a design-based research method with the purpose of using it in teaching of natural science topics and to look into student evaluations. In the study which employed design-based research model, developed contents were applied, analysed and re-designed with students constantly. The study group of the research consisted of forty 7th grade students at a private college in 2016-2017 fall semester. Augmented reality contents developed for science teaching were evaluated by teachers and students as effective. According to the teacher and student opinions, it was concluded that augmented reality contents of science teaching developed during design-based research process was nice, easily applicable and useful. It can be said that while developing educative materials for students, applying design-based research model and paying attention to material design principles secures the effectiveness of the developed material.

  3. GNApp - an open source augmentative and alternative communication framework

    CSIR Research Space (South Africa)

    Coetzee, L

    2006-02-01

    Full Text Available them to improve the quality of their lives; • Addresses a critical human need to communicate with others through new and affordable technology; • Aims to generate tangible outputs in the form of technology building blocks and technology demonstrators...; and • Operates in partnership with a representative group of Disabled Persons’ Organisations and the Office on the Status of Disabled Persons (OSDP) in the Presidency. AAC – WHAT IS AUGMENTATIVE AND ALTERNATIVE COMMUNICATION? • AAC is the supplementation and...

  4. Facial skeletal augmentation using hydroxyapatite cement.

    Science.gov (United States)

    Shindo, M L; Costantino, P D; Friedman, C D; Chow, L C

    1993-02-01

    This study investigates the use of a new calcium phosphate cement, which sets to solid, microporous hydroxyapatite, for facial bone augmentation. In six dogs, the supraorbital ridges were augmented bilaterally with this hydroxyapatite cement. On one side, the hydroxyapatite cement was placed directly onto the bone within a subperiosteal pocket. On the opposite side, the cement was contained within a collagen membrane tubule and then inserted into a subperiosteal pocket. The use of collagen tubules facilitated easy, precise placement of the cement. All implants maintained their original augmented height throughout the duration of the study. They were well tolerated without extrusion or migration, and there was no significant sustained inflammatory response. Histologic studies, performed at 3, 6, and 9 months revealed that when the cement was placed directly onto bone, progressive replacement of the implant by bone (osseointegration of the hydroxyapatite with the underlying bone) without a loss of volume was observed. In contrast, when the cement-collagen tubule combination was inserted, primarily a fibrous union was noted. Despite such fibrous union, the hydroxyapatite-collagen implant solidly bonded to the underlying bone, and no implant resorption was observed. Hydroxyapatite cement can be used successfully for the experimental augmentation of the craniofacial skeleton and may be applicable for such uses in humans.

  5. Source location in plates based on the multiple sensors array method and wavelet analysis

    International Nuclear Information System (INIS)

    Yang, Hong Jun; Shin, Tae Jin; Lee, Sang Kwon

    2014-01-01

    A new method for impact source localization in a plate is proposed based on the multiple signal classification (MUSIC) and wavelet analysis. For source localization, the direction of arrival of the wave caused by an impact on a plate and the distance between impact position and sensor should be estimated. The direction of arrival can be estimated accurately using MUSIC method. The distance can be obtained by using the time delay of arrival and the group velocity of the Lamb wave in a plate. Time delay is experimentally estimated using the continuous wavelet transform for the wave. The elasto dynamic theory is used for the group velocity estimation.

  6. Source location in plates based on the multiple sensors array method and wavelet analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Hong Jun; Shin, Tae Jin; Lee, Sang Kwon [Inha University, Incheon (Korea, Republic of)

    2014-01-15

    A new method for impact source localization in a plate is proposed based on the multiple signal classification (MUSIC) and wavelet analysis. For source localization, the direction of arrival of the wave caused by an impact on a plate and the distance between impact position and sensor should be estimated. The direction of arrival can be estimated accurately using MUSIC method. The distance can be obtained by using the time delay of arrival and the group velocity of the Lamb wave in a plate. Time delay is experimentally estimated using the continuous wavelet transform for the wave. The elasto dynamic theory is used for the group velocity estimation.

  7. Topiramate augmentation in clozapine-treated patients with schizophrenia: clinical and metabolic effects.

    Science.gov (United States)

    Hahn, Margaret K; Remington, Gary; Bois, Daniel; Cohn, Tony

    2010-12-01

    Clozapine represents the treatment of choice for refractory psychosis, although a significant number of individuals demonstrate suboptimal response to it as well, leading to clozapine augmentation strategies. A variety of agents have been investigated in this regard, including mood stabilizers, such as anticonvulsants. Within this group of medications, topiramate is unique in that it is associated with weight loss, making it an attractive option because of clozapine's notable risk for associated metabolic disturbance. A 12-week naturalistic, open study was carried out to examine the potential benefits of topiramate in clozapine-treated individuals with schizophrenia demonstrating a suboptimal clinical response. We were specifically interested in clinical symptoms, changes in metabolic parameters, and tolerability. A total of 20 subjects were enrolled, and 16 completed the study, including 5 individuals with type 2 diabetes. Topiramate augmentation led to a 14% improvement in total Brief Psychiatric Rating Scale scores (P = 0.0003), a 2.5% decrease in body weight (P = 0.015), and was generally well tolerated, paraesthesia being the most common side effect. These findings support topiramate as a viable augmentation strategy in clozapine partial responders, with evidence of both clinical and metabolic benefits.

  8. Giardia muris and Giardia duodenalis groups: ultrastructural differences between the trophozoites

    Directory of Open Access Journals (Sweden)

    Maria Inês L. Sogayar

    1989-08-01

    Full Text Available Trophozoites of the Giardia muris group from hamsters, domestic rats and mice and of the Giardia duodenalis group from hamsters and domestic rats were examined by transmission electron microscopy. The basic ultrastructure of the trophozoites was similar. Differences were shown in the morphology of the ventrolateral flange of the trophozoites of Giardia muris and Giardia duodenalis groups. Marginal plates are less developed in the species of the Giardia duodenalis group. In this group, the distal extremity of the lateral flange is short and thick and the marginal plate does not penetrate into the distal extremity of the flange. In the Giardia muris group, the ventro-lateral flange is well developed and narrow and the marginal plate penetrates the distal extremity of the flange. The osmiophilic lamella, which accompanies the dorsal surface of the marginal plate is seen only in the Giardia muris group.

  9. Interactive Anatomy-Augmented Virtual Simulation Training.

    Science.gov (United States)

    Aebersold, Michelle; Voepel-Lewis, Terri; Cherara, Leila; Weber, Monica; Khouri, Christina; Levine, Robert; Tait, Alan R

    2018-02-01

    Traditionally, clinical psychomotor skills are taught through videos and demonstration by faculty which does not allow for the visualization of internal structures and anatomical landmarks that would enhance the learner skill performance. Sophomore and junior nursing students attending a large Midwestern Institution (N=69) participated in this mixed methods study. Students demonstrated their ability to place a nasogastric tube (NGT) after being randomly assigned to usual training (Control group) or an iPad anatomy-augmented virtual simulation training module (AR group). The ability of the participants to demonstrate competence in placing the NGT was assessed using a 17-item competency checklist. After the demonstration, students completed a survey to elicit information about students' level of training, prior experience with NGT placement, satisfaction with the AR technology, and perceptions of AR as a potential teaching tool for clinical skills training. The ability to correctly place the NGT through all the checklist items was statistically significant in the AR group compared with the control group (P = 0.011). Eighty-six percent of participants in the AR group rated AR as superior/far superior to other procedural training programs to which they had been exposed, whereas, only 5.9% of participants in the control group rated the control program as superior/far superior (P < 0.001). Overall the AR module was better received compared with the control group with regards to realism, identifying landmarks, visualization of internal organs, ease of use, usefulness, and promoting learning and understanding.

  10. Design and measured performances of a plane reflector augmented box-type solar-energy cooker

    International Nuclear Information System (INIS)

    Ekechukwu, O.V.

    2001-06-01

    The design philosophy, construction and measured performances of a plane-reflector augmented box-type solar-energy cooker are presented. The experimental solar cooker consists of an aluminum plate absorber painted matt black and a double-glazed lid. The bottom and sides are lagged with fibreglass wool insulator. The reflector consists of a wooden-framed commercially-available specular plane mirror which is sized to form a cover for the box when not in use. Provision is made for four cooking vessels each capable of holding up to 1 kg of water. Results of thermal performance tests show stagnation absorber plate temperatures of 138 deg. C and 119 deg. C for the cooker with and without the plane reflector in place, respectively. Boiling times of 60 minutes (3600 seconds) and 70 minutes (4200 seconds) for 1 kg of water, for the cooker with and without the reflector in place, respectively, were recorded. The solar cooker performance has been rated using the first figure of merit (F 1 ) on the no-load test and the second figure of merit (F 2 ) on the sensible heat tests. Predicted water boiling times using the two figures of merit compared favourable with measured values. The performance of the cooker with the plane reflector in place was improved tremendously compared to that without the reflector in place. (author)

  11. History of internal fixation with plates (part 2): new developments after World War II; compressing plates and locked plates.

    Science.gov (United States)

    Hernigou, Philippe; Pariat, Jacques

    2017-07-01

    The first techniques of operative fracture with plates were developed in the 19th century. In fact, at the beginning these methods consisted of an open reduction of the fracture usually followed by a very unstable fixation. As a consequence, the fracture had to be opened with a real risk of (sometimes lethal) infection, and due to unstable fixation, protection with a cast was often necessary. During the period between World Wars I and II, plates for fracture fixation developed with great variety. It became increasingly recognised that, because a fracture of a long bone normally heals with minimal resorption at the bone ends, this may result in slight shortening and collapse, so a very rigid plate might prevent such collapse. However, as a consequence, delayed healing was observed unless the patient was lucky enough to have the plate break. One way of dealing with this was to use a slotted plate in which the screws could move axially, but the really important advance was recognition of the role of compression. After the first description of compression by Danis with a "coapteur", Bagby and Müller with the AO improved the technique of compression. The classic dynamic compression plates from the 1970s were the key to a very rigid fixation, leading to primary bone healing. Nevertheless, the use of strong plates resulted in delayed union and the osteoporosis, cancellous bone, comminution, and/or pathological bone resulted in some failures due to insufficient stability. Finally, new devices represented by locking plates increased the stability, contributing to the principles of a more biological osteosynthesis while giving enough stability to allow immediate full weight bearing in some patients.

  12. Applying Augmented Reality in practical classes for engineering students

    Science.gov (United States)

    Bazarov, S. E.; Kholodilin, I. Yu; Nesterov, A. S.; Sokhina, A. V.

    2017-10-01

    In this article the Augmented Reality application for teaching engineering students of electrical and technological specialties is introduced. In order to increase the motivation for learning and the independence of students, new practical guidelines on Augmented Reality were developed in the application to practical classes. During the application development, the authors used software such as Unity 3D and Vuforia. The Augmented Reality content consists of 3D-models, images and animations, which are superimposed on real objects, helping students to study specific tasks. A user who has a smartphone, a tablet PC, or Augmented Reality glasses can visualize on-screen virtual objects added to a real environment. Having analyzed the current situation in higher education: the learner’s interest in studying, their satisfaction with the educational process, and the impact of the Augmented Reality application on students, a questionnaire was developed and offered to students; the study involved 24 learners.

  13. Influence of dressing application time after breast augmentation on cutaneous colonization: A randomized clinical trial.

    Science.gov (United States)

    Mendes, D A; Veiga, D F; Veiga-Filho, J; Loyola, A B A T; Paiva, L F; Novo, N F; Sabino-Neto, M; Ferreira, L M

    2018-06-01

    Concepts regarding the best way to treat a surgical wound vary, in literature, ranging from no dressing use to dressing maintenance for 24 to 48 hours or until suture removal. This study aimed to evaluate the influence of the length of dressing maintenance after breast augmentation with implants on cutaneous colonization and surgical site infection. This is a two-arm, parallel group, randomized clinical trial. Eighty patients who were candidates for augmentation mammoplasty with silicone implants were randomly allocated to two groups, in which the dressing was removed on postoperative day 1 (group A, n = 40) or postoperative day 6 (group B, n = 40). Cutaneous colonization was examined by culturing samples collected before and after dressing removal. The criteria defined by the Centers for Disease Control and Prevention were used to assess surgical site infection. No significant difference regarding cutaneous colonization was observed between groups before dressing application. On postoperative day 6, significantly more bacterial growth was observed in group A (p = 0.01). No surgical site infection occurred. We concluded that maintaining the dressing for 6 days led to a lower cutaneous colonization but did not influence surgical site infection rates. Copyright © 2018 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  14. Sensor-augmented pump therapy at 36 months

    DEFF Research Database (Denmark)

    Schmidt, Signe; Nørgaard, Kirsten

    2012-01-01

    This follow-up study investigates the metabolic and psychosocial effects of sensor-augmented pump (SAP) therapy in adults with type 1 diabetes 36 months after therapy start.......This follow-up study investigates the metabolic and psychosocial effects of sensor-augmented pump (SAP) therapy in adults with type 1 diabetes 36 months after therapy start....

  15. Augmented Reality, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Augmented Reality systems come with many benefits derived by co-locating information with a user's environment through the use of one or more output modalities such...

  16. The group environment of Seyfert galaxies. II. Spectrophotometry of galaxies in groups

    International Nuclear Information System (INIS)

    Fricke, K.J.; Kollatschny, W.

    1989-01-01

    Medium-resolution spectrophotometric data of 104 galaxies have been obtained. These galaxies are members of 22 loose groups of < 1 Mpc size. Thirteen of these groups contain Seyfert galaxies. In this paper we present calibrated emission-line data and absolute optical spectra of the individual galaxies as well as plates of each group

  17. Cosmetic tourism for breast augmentation: a systematic review.

    Science.gov (United States)

    Brightman, Louise; Ng, Sze; Ahern, Susannah; Cooter, Rodney; Hopper, Ingrid

    2017-12-03

    The medical tourism industry, and in particular cosmetic tourism for breast augmentation, is becoming an increasingly popular global phenomenon. The objective of this study is to determine the extent of medical literature and the patient risk profiles associated with cosmetic tourism for breast augmentation both locally and abroad. OVID MEDLINE, OVID Embase, Cochrane Central and Proquest electronic databases. The search was conducted through to April 2017. Studies pertaining entirely or partly to cosmetic tourism for breast augmentation were considered for inclusion. Exclusion criteria included non-English articles, studies relating to non-cosmetic or non-implant breast augmentation, and studies that did not separately report on findings associated with breast augmentation abroad. We identified 17 observational studies. Common destinations included Europe, South America and South East Asia. Infectious complications were common. Wound dehiscence and aesthetic dissatisfaction also featured. Catastrophic outcomes such as sepsis, intubation and ventilation, radical bilateral mastectomy, irreversible hypoxic brain injury and death were also reported. There were expectations that home country health systems would treat complications and provide non-medically indicated revision procedures. The burden on home country health systems was evident from a public health perspective. Determining the extent of cosmetic tourism for breast augmentation, including outcomes and complications, will help to inform Australian patients who this seek procedure abroad. Furthermore, it will aid in better understanding the health system implications and may help to guide future research and public health interventions both locally and internationally. © 2017 Royal Australasian College of Surgeons.

  18. Immediate breast reconstruction after skin- or nipple-sparing mastectomy for previously augmented patients: a personal technique.

    Science.gov (United States)

    Salgarello, Marzia; Rochira, Dario; Barone-Adesi, Liliana; Farallo, Eugenio

    2012-04-01

    Breast reconstruction for previously augmented patients differs from breast reconstruction for nonaugmented patients. Many surgeons regard conservation therapy as not feasible for these patients because of implant complications, whether radiotherapy-induced or not. Despite this, most authors agree that mastectomy with immediate breast reconstruction is the most suitable choice, ensuring both a good cosmetic result and a low complication rate. Implant retention or removal remains a controversial topic in addition to the best available surgical technique. This study reviewed the authors' experience with immediate breast reconstruction after skin-sparing mastectomy (SSM) and nipple-sparing mastectomy (NSM) with anatomically definitive implants. The retrospective records of 12 patients were examined (group A). These patients were among 254 patients who underwent SSM or NSM for breast carcinoma. The control group comprised 12 of the 254 patients submitted to SSM or NSM (group B) who best matched the 12 patients in the studied group. All of them underwent immediate breast reconstruction, with an anatomically definitive implant placed in a submuscular-subfascial pocket. The demographic, technical, and oncologic data of the two groups were compared as well as the aesthetic outcomes using the Breast Q score. The proportion of complications, the type of implant, the axillary lymph node procedure, and the histology were compared between the two groups using Fisher's exact test. Student's t test was used to compare the scores for the procedure-specific modules of the breast Q questionnaire in the two groups. A validated patient satisfaction score was obtained using the breast Q questionnaire after breast reconstruction. The demographic, technical, and oncologic characteristics were not significantly different between the two groups. The previously augmented patients reported a significantly higher level of satisfaction with their breast than the control patients. The scores

  19. The Importance of Lower Mantle Structure to Plate Stresses and Plate Motions

    Science.gov (United States)

    Holt, W. E.; Wang, X.; Ghosh, A.

    2016-12-01

    Plate motions and plate stresses are widely assumed as the surface expression of mantle convection. The generation of plate tectonics from mantle convection has been studied for many years. Lithospheric thickening (or ridge push) and slab pull forces are commonly accepted as the major driving forces for the plate motions. However, the importance of the lower mantle to plate stresses and plate motions remains less clear. Here, we use the joint modeling of lithosphere and mantle dynamics approach of Wang et al. (2015) to compute the tractions originating from deeper mantle convection and follow the method of Ghosh et al. (2013) to calculate gravitational potential energy per unit area (GPE) based on Crust 1.0 (Laske et al., 2013). Absolute values of deviatoric stresses are determined by the body force distributions (GPE gradients and traction magnitudes applied at the base of the lithosphere). We use the same relative viscosity model that Ghosh et al. (2013) used, and we solve for one single adjustable scaling factor that multiplies the entire relative viscosity field to provide absolute values of viscosity throughout the lithosphere. This distribution of absolute values of lithosphere viscosities defines the magnitudes of surface motions. In this procedure, the dynamic model first satisfies the internal constraint of no-net-rotation of motions. The model viscosity field is then scaled by the single factor until we achieve a root mean square (RMS) minimum between computed surface motions and the kinematic no-net-rotation (NNR) model of Kreemer et al. (2006). We compute plate stresses and plate motions from recently published global tomography models (over 70 based on Wang et al., 2015). We find that RMS misfits are significantly reduced when details of lower mantle structure from the latest tomography models are added to models that contain only upper and mid-mantle density distributions. One of the key reasons is that active upwelling from the Large Low Shear

  20. Exploration Augmentation Module Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Exploration Augmentation Module (EAM) project goal is to design and deliver a flight module that is to be deployed to Earth-Lunar Distant Retrograde Orbit (DRO)....

  1. Power training using pneumatic machines vs. plate-loaded machines to improve muscle power in older adults.

    Science.gov (United States)

    Balachandran, Anoop T; Gandia, Kristine; Jacobs, Kevin A; Streiner, David L; Eltoukhy, Moataz; Signorile, Joseph F

    2017-11-01

    Power training has been shown to be more effective than conventional resistance training for improving physical function in older adults; however, most trials have used pneumatic machines during training. Considering that the general public typically has access to plate-loaded machines, the effectiveness and safety of power training using plate-loaded machines compared to pneumatic machines is an important consideration. The purpose of this investigation was to compare the effects of high-velocity training using pneumatic machines (Pn) versus standard plate-loaded machines (PL). Independently-living older adults, 60years or older were randomized into two groups: pneumatic machine (Pn, n=19) and plate-loaded machine (PL, n=17). After 12weeks of high-velocity training twice per week, groups were analyzed using an intention-to-treat approach. Primary outcomes were lower body power measured using a linear transducer and upper body power using medicine ball throw. Secondary outcomes included lower and upper body muscle muscle strength, the Physical Performance Battery (PPB), gallon jug test, the timed up-and-go test, and self-reported function using the Patient Reported Outcomes Measurement Information System (PROMIS) and an online video questionnaire. Outcome assessors were blinded to group membership. Lower body power significantly improved in both groups (Pn: 19%, PL: 31%), with no significant difference between the groups (Cohen's d=0.4, 95% CI (-1.1, 0.3)). Upper body power significantly improved only in the PL group, but showed no significant difference between the groups (Pn: 3%, PL: 6%). For balance, there was a significant difference between the groups favoring the Pn group (d=0.7, 95% CI (0.1, 1.4)); however, there were no statistically significant differences between groups for PPB, gallon jug transfer, muscle muscle strength, timed up-and-go or self-reported function. No serious adverse events were reported in either of the groups. Pneumatic and plate

  2. Intravenous alpha-1 antitrypsin augmentation therapy: systematic review

    DEFF Research Database (Denmark)

    Gøtzsche, Peter C; Johansen, Helle Krogh

    2010-01-01

    We reviewed the benefits and harms of augmentation therapy with alpha-1 antitrypsin in patients with alpha-1 antitrypsin deficiency and lung disease. We searched for randomised trials comparing augmentation therapy with placebo or no treatment in PubMed and ClinicalTrials (7 January 2010). Two...... (difference 1.14 g/l; 95% confidence interval 0.14 to 2.14; p = 0.03) over the total course of the trials. Augmentation therapy with alpha-1 antitrypsin cannot be recommended in view of the lack of evidence of clinical benefit and the cost of treatment....

  3. Bone formation in sinus augmentation procedures using autologous bone, porcine bone, and a 50 : 50 mixture: a human clinical and histological evaluation at 2 months.

    Science.gov (United States)

    Cassetta, Michele; Perrotti, Vittoria; Calasso, Sabrina; Piattelli, Adriano; Sinjari, Bruna; Iezzi, Giovanna

    2015-10-01

    The aim of this study was to perform a 2 months clinical and histological comparison of autologous bone, porcine bone, and a 50 : 50 mixture in maxillary sinus augmentation procedures. A total of 10 consecutive patients, undergoing two-stage sinus augmentation procedures using 100% autologous bone (Group A), 100% porcine bone (Group B), and a 50 : 50 mixture of autologous and porcine bone (Group C) were included in this study. After a 2-month healing period, at the time of implant insertion, clinical evaluation was performed and bone core biopsies were harvested and processed for histological analysis. The postoperative healing was uneventful regardless of the materials used for the sinus augmentation procedures. The histomorphometrical analysis revealed comparable percentages of newly formed bone, marrow spaces, and residual grafted material in the three groups. The clinical and histological results of this study indicated that porcine bone alone or in combination with autologous bone are biocompatible and osteoconductive materials and can be successfully used in sinus augmentation procedures. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Finite-Element Modeling of Timber Joints with Punched Metal Plate Fasteners

    DEFF Research Database (Denmark)

    Ellegaard, Peter

    2006-01-01

    The focus of this paper is to describe the idea and the theory behind a finite-element model developed for analysis of timber trusses with punched metal plate fasteners (nail plates). The finite-element model includes the semirigid and nonlinear behavior of the joints (nonlinear nail and plate...... elements) and contact between timber beams, if any (bilinear contact elements). The timber beams have linear-elastic properties. The section forces needed for design of the joints are given directly by the finite-element model, since special elements are used to model the nail groups and the nail plate...... the behavior of the joints very well at lower load levels. At higher load levels the stiffness is overestimated due to development of cracks in the timber and the linear-elastic timber properties in the finite-element model....

  5. LEARNING ANATOMY WITH AUGMENTED REALITY

    DEFF Research Database (Denmark)

    Nørgaard, Cita; Dyhrberg O'Neill, Lotte; Nielsen, Kurt Gammelgaard

    An Augmented Reality (AR) app for Hololens glasses was developed to help students learn the anatomy of the human body mediastinum. In this research project, we wanted to evaluate whether AR: strengthened the students’ self-efficacy and motivation, helped students to improve learning, and provided...... a questionnaire regarding their self-efficacy and motivation, presence in the virtual room, experiences with Hololens teaching, and how they used the quizzes. In addition, students answered a test with the same 20 questions used in the app and three additional transfer questions new to students. Finally, students......’ scores on the mediastinum questions in the exam 2 month later were collected to examine the long-term memory of content. Internal consistency was estimated for all measures. Correlations between measures were examined with a correlation matrix, and group differences were examined with one-way analysis...

  6. Acute high-grade acromioclavicular joint injuries: quality of life comparison between patients managed operatively with a hook plate versus patients managed non-operatively.

    Science.gov (United States)

    Natera Cisneros, Luis Gerardo; Sarasquete Reiriz, Juan

    2017-04-01

    Surgical indication for acromioclavicular joint (ACJ) injuries still represents a reason for shoulder and trauma debate. In high-grade injuries, surgery is advocated because some of the non-operatively managed patients may have persistent shoulder pain that could make them unable to return to their previous activity. It has been shown that many of the patients with high-grade ACJ injuries that are managed non-operatively involve the development of scapular dyskinesis, situation that may result in loss of strength and weakness. On the other side, it has been widely reported that the period while the hook plate is present involves functional limitations and pain. The purpose of this study was to compare the quality of life (QoL) of patients with acute high-grade ACJ injuries (Rockwood grade III-V), managed operatively with a hook plate versus the QoL of patients managed non-operatively, 24 months or more after shoulder injury. Patients with acute high-grade ACJ injuries managed operatively (hook plate) or non-operatively, between 2008 and 2012 were included. The QoL was evaluated by means of the Health Survey questionnaire (SF36), the Visual Analogue Scale (VAS) for pain, the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire, the Constant score and the Global Satisfaction (scale from 0 to 10) assessed at the last follow-up visit. The presence of scapular dyskinesis was assessed. Comparison between groups was made. Thirty-two patients were included: 11 hook plate-group (PLATE group) (5 Rockwood III and 6 V) and 21 conservative-group (CONS group) (4 Rockwood III and 17 V). The mean age was 41 [19-55] years old for the PLATE group and 38 [19-55] for the CONS group (p = 0.513). The mean follow-up was 32.50 ± 11.64 months for the PLATE group and 34.77 ± 21.98 months for the CONS group (p = 0.762). The mean results of the questionnaires assessed at the last follow-up visit were: (1) physical SF36 score (PLATE group 53.70 ± 4.33 and CONS group

  7. Pemanfaatan Augmented Reality Pada Permainan Othello

    Directory of Open Access Journals (Sweden)

    Rendy Layman Aguston

    2016-11-01

    Full Text Available Perkembangan teknologi telah mengubah cara pengerjaan suatu pekerjaan dari cara konvensional menjadi cara yang lebih praktis. Dengan hadirnya teknologi Augmented Reality, cara bermain yang menggunakan pion dan membalikkan pion musuh secara manual menjadi lebih mudah dalam memainkan permainan selain juga dapat berinteraksi langsung. Pembuatan permainan Othello menggunakan program Unity dengan framework Vuforia untuk mewujudkan Augmented Reality pada permainan Othello. Untuk menerapkan Augmented Reality dengan baik, dibutuhkan papan permainan sebagai image target yang sesuai dengan kriteria, jenis kamera yang digunakan, jarak kamera terhadap papan permainan, intensitas cahaya yang ditangkap kamera, serta tingkat sensitivitas tombol virtual. Pada permainan Othello ini tersedia fitur komputer yang menggunakan algoritma Alpha Beta Pruning dengan 3 level kedalaman yang menggunakan perhitungan fungsi evaluasi berupa mobility, potential mobility dan penguasaan corner yang menghasilkan kemenangan mencapai 73,33% dari 15 kali uji coba terhadap aplikasi Othello serupa dan 78,34% dari 37 kali uji coba terhadap user.

  8. An augmented reality system for upper-limb post-stroke motor rehabilitation: a feasibility study.

    Science.gov (United States)

    Assis, Gilda Aparecida de; Corrêa, Ana Grasielle Dionísio; Martins, Maria Bernardete Rodrigues; Pedrozo, Wendel Goes; Lopes, Roseli de Deus

    2016-08-01

    To determine the clinical feasibility of a system based on augmented reality for upper-limb (UL) motor rehabilitation of stroke participants. A physiotherapist instructed the participants to accomplish tasks in augmented reality environment, where they could see themselves and their surroundings, as in a mirror. Two case studies were conducted. Participants were evaluated pre- and post-intervention. The first study evaluated the UL motor function using Fugl-Meyer scale. Data were compared using non-parametric sign tests and effect size. The second study used the gain of motion range of shoulder flexion and abduction assessed by computerized biophotogrammetry. At a significance level of 5%, Fugl-Meyer scores suggested a trend for greater UL motor improvement in the augmented reality group than in the other. Moreover, effect size value 0.86 suggested high practical significance for UL motor rehabilitation using the augmented reality system. System provided promising results for UL motor rehabilitation, since enhancements have been observed in the shoulder range of motion and speed. Implications for Rehabilitation Gain of range of motion of flexion and abduction of the shoulder of post-stroke patients can be achieved through an augmented reality system containing exercises to promote the mental practice. NeuroR system provides a mental practice method combined with visual feedback for motor rehabilitation of chronic stroke patients, giving the illusion of injured upper-limb (UL) movements while the affected UL is resting. Its application is feasible and safe. This system can be used to improve UL rehabilitation, an additional treatment past the traditional period of the stroke patient hospitalization and rehabilitation.

  9. Catalysts characteristics of Ni/YSZ core-shell according to plating conditions using electroless plating

    Science.gov (United States)

    Park, Hyun-Wook; Jang, Jae-Won; Lee, Young-Jin; Kim, Jin-Ho; Jeon, Dae-Woo; Lee, Jong-Heun; Hwang, Hae-jin; Lee, Mi-Jai

    2017-11-01

    This study aims to develop an anode catalyst for a solid oxide fuel cell (SOFC) using electroless nickel plating. We have proposed a new method for electroless plating of Ni metal on yttria-stabilized zirconia (YSZ) particles. We examine the uniformity of the Ni layer on the plated core-shell powder, in addition to the content of Ni and the reproducibility of the plating. We have also evaluated the carbon deposition rate and characteristics of the SOFC anode catalyst. To synthesize Ni-plated YSZ particles, the plated powder is heat-treated at 1200 °C. The resultant particles, which have an average size of 50 μm, were subsequently used in the experiment. The size of the Ni particles and the Ni content both increase with increasing plating temperature and plating time. The X-ray diffraction pattern reveals the growth of Ni particles. After heat-treatment, Ni is oxidized to NiO, leading to the co-existence of Ni and NiO; Ni3P is also observed due to the presence of phosphorous in the plating solution. Following heat treatment for 1 h at 1200 °C, Ni is mostly oxidized to NiO. The carbon deposition rate of the reference YSZ powder is 135%, while that of the Ni-plated YSZ is 1%-6%.

  10. Clinical and optical intraocular performance of rotationally asymmetric multifocal IOL plate-haptic design versus C-loop haptic design.

    Science.gov (United States)

    Alió, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José; Vega-Estrada, Alfredo

    2013-04-01

    To compare the visual and intraocular optical quality outcomes with different designs of the refractive rotationally asymmetric multifocal intraocular lens (MFIOL) (Lentis Mplus; Oculentis GmbH, Berlin, Germany) with or without capsular tension ring (CTR) implantation. One hundred thirty-five consecutive eyes of 78 patients with cataract (ages 36 to 82 years) were divided into three groups: 43 eyes implanted with the C-Loop haptic design without CTR (C-Loop haptic only group); 47 eyes implanted with the C-Loop haptic design with CTR (C-Loop haptic with CTR group); and 45 eyes implanted with the plate-haptic design (plate-haptic group). Visual acuity, contrast sensitivity, defocus curve, and ocular and intraocular optical quality were evaluated at 3 months postoperatively. Significant differences in the postoperative sphere were found (P = .01), with a more myopic postoperative refraction for the C-Loop haptic only group. No significant differences were detected in photopic and scotopic contrast sensitivity among groups (P ⩾ .05). Significantly better visual acuities were present in the C-Loop haptic with CTR group for the defocus levels of -2.0, -1.5, -1.0, and -0.50 D (P ⩽.03). Statistically significant differences among groups were found in total intraocular root mean square (RMS), high-order intraocular RMS, and intraocular coma-like RMS aberrations (P ⩽.04), with lower values from the plate-haptic group. The plate-haptic design and the C-Loop haptic design with CTR implantation both allow good visual rehabilitation. However, better refractive predictability and intraocular optical quality was obtained with the plate-haptic design without CTR implantation. The plate-haptic design seems to be a better design to support rotational asymmetric MFIOL optics. Copyright 2013, SLACK Incorporated.

  11. Fuel cell end plate structure

    Science.gov (United States)

    Guthrie, Robin J.; Katz, Murray; Schroll, Craig R.

    1991-04-23

    The end plates (16) of a fuel cell stack (12) are formed of a thin membrane. Pressure plates (20) exert compressive load through insulation layers (22, 26) to the membrane. Electrical contact between the end plates (16) and electrodes (50, 58) is maintained without deleterious making and breaking of electrical contacts during thermal transients. The thin end plate (16) under compressive load will not distort with a temperature difference across its thickness. Pressure plate (20) experiences a low thermal transient because it is insulated from the cell. The impact on the end plate of any slight deflection created in the pressure plate by temperature difference is minimized by the resilient pressure pad, in the form of insulation, therebetween.

  12. Mobile Augmented Note-taking to Support Operating Physical Devices

    OpenAIRE

    Liu , Can; Diehl , Jonathan; Huot , Stéphane; Borchers , Jan

    2011-01-01

    Mobile Augmented Reality: Design Issues and Opportunities - 1st Workshop on Mobile Augmented Reality, MobileHCI 2011; In this paper we propose an approach to assist operating physical devices with mobile augmented reality techniques. We propose ideas of interaction techniques, which allow users to put self-authored information as notes onto physical objects. We present the design of two example applications aiming at solving problems from different aspects of physical operations.

  13. Clinical applications of cell-based approaches in alveolar bone augmentation: a systematic review.

    Science.gov (United States)

    Shanbhag, Siddharth; Shanbhag, Vivek

    2015-01-01

    Cell-based approaches, utilizing adult mesenchymal stem cells (MSCs), are reported to overcome the limitations of conventional bone augmentation procedures. The study aims to systematically review the available evidence on the characteristics and clinical effectiveness of cell-based ridge augmentation, socket preservation, and sinus-floor augmentation, compared to current evidence-based methods in human adult patients. MEDLINE, EMBASE, and CENTRAL databases were searched for related literature. Both observational and experimental studies reporting outcomes of "tissue engineered" or "cell-based" augmentation in ≥5 adult patients alone, or in comparison with non-cell-based (conventional) augmentation methods, were eligible for inclusion. Primary outcome was histomorphometric analysis of new bone formation. Effectiveness of cell-based augmentation was evaluated based on outcomes of controlled studies. Twenty-seven eligible studies were identified. Of these, 15 included a control group (8 randomized controlled trials [RCTs]), and were judged to be at a moderate-to-high risk of bias. Most studies reported the combined use of cultured autologous MSCs with an osteoconductive bone substitute (BS) scaffold. Iliac bone marrow and mandibular periosteum were frequently reported sources of MSCs. In vitro culture of MSCs took between 12 days and 1.5 months. A range of autogenous, allogeneic, xenogeneic, and alloplastic scaffolds was identified. Bovine bone mineral scaffold was frequently reported with favorable outcomes, while polylactic-polyglycolic acid copolymer (PLGA) scaffold resulted in graft failure in three studies. The combination of MSCs and BS resulted in outcomes similar to autogenous bone (AB) and BS. Three RCTs and one controlled trial reported significantly greater bone formation in cell-based than conventionally grafted sites after 3 to 8 months. Based on limited controlled evidence at a moderate-to-high risk of bias, cell-based approaches are comparable, if

  14. Techniques used by United Kingdom consultant plastic surgeons to select implant size for primary breast augmentation.

    Science.gov (United States)

    Holmes, W J M; Timmons, M J; Kauser, S

    2015-10-01

    Techniques used to estimate implant size for primary breast augmentation have evolved since the 1970s. Currently no consensus exists on the optimal method to select implant size for primary breast augmentation. In 2013 we asked United Kingdom consultant plastic surgeons who were full members of BAPRAS or BAAPS what was their technique for implant size selection for primary aesthetic breast augmentation. We also asked what was the range of implant sizes they commonly used. The answers to question one were grouped into four categories: experience, measurements, pre-operative external sizers and intra-operative sizers. The response rate was 46% (164/358). Overall, 95% (153/159) of all respondents performed some form of pre-operative assessment, the others relied on "experience" only. The most common technique for pre-operative assessment was by external sizers (74%). Measurements were used by 57% of respondents and 3% used intra-operative sizers only. A combination of measurements and sizers was used by 34% of respondents. The most common measurements were breast base (68%), breast tissue compliance (19%), breast height (15%), and chest diameter (9%). The median implant size commonly used in primary breast augmentation was 300cc. Pre-operative external sizers are the most common technique used by UK consultant plastic surgeons to select implant size for primary breast augmentation. We discuss the above findings in relation to the evolution of pre-operative planning techniques for breast augmentation. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  15. Augmented Reality 2.0

    Science.gov (United States)

    Schmalstieg, Dieter; Langlotz, Tobias; Billinghurst, Mark

    Augmented Reality (AR) was first demonstrated in the 1960s, but only recently have technologies emerged that can be used to easily deploy AR applications to many users. Camera-equipped cell phones with significant processing power and graphics abilities provide an inexpensive and versatile platform for AR applications, while the social networking technology of Web 2.0 provides a large-scale infrastructure for collaboratively producing and distributing geo-referenced AR content. This combination of widely used mobile hardware and Web 2.0 software allows the development of a new type of AR platform that can be used on a global scale. In this paper we describe the Augmented Reality 2.0 concept and present existing work on mobile AR and web technologies that could be used to create AR 2.0 applications.

  16. Heat insulating plates

    Energy Technology Data Exchange (ETDEWEB)

    Allan, J.A.F.

    1976-10-28

    Micro-porous insulation plates are dealt with, for example, how they are used in the insulation of heat storage devices. Since one side of such plates is exposed to a temperature of over 700/sup 0/C, a shrinkage of the glass texture of the covering can occur, which can exceed the shrinkage of the inner micro-porous material, so that cracks and splits in the high temperature side of the covering can come about. The task of the invention is to design the plate in such a way as to prevent this from happening. For this purpose the plate is provided, according to invention specifications, with flutes, waves, ribs, waffle or grid patterns and the covering is set into the recesses originating from this.

  17. Personalized augmented reality for anatomy education.

    Science.gov (United States)

    Ma, Meng; Fallavollita, Pascal; Seelbach, Ina; Von Der Heide, Anna Maria; Euler, Ekkehard; Waschke, Jens; Navab, Nassir

    2016-05-01

    Anatomy education is a challenging but vital element in forming future medical professionals. In this work, a personalized and interactive augmented reality system is developed to facilitate education. This system behaves as a "magic mirror" which allows personalized in-situ visualization of anatomy on the user's body. Real-time volume visualization of a CT dataset creates the illusion that the user can look inside their body. The system comprises a RGB-D sensor as a real-time tracking device to detect the user moving in front of a display. In addition, the magic mirror system shows text information, medical images, and 3D models of organs that the user can interact with. Through the participation of 7 clinicians and 72 students, two user studies were designed to respectively assess the precision and acceptability of the magic mirror system for education. The results of the first study demonstrated that the average precision of the augmented reality overlay on the user body was 0.96 cm, while the results of the second study indicate 86.1% approval for the educational value of the magic mirror, and 91.7% approval for the augmented reality capability of displaying organs in three dimensions. The usefulness of this unique type of personalized augmented reality technology has been demonstrated in this paper. © 2015 Wiley Periodicals, Inc.

  18. Fuel cell cooler-humidifier plate

    Science.gov (United States)

    Vitale, Nicholas G.; Jones, Daniel O.

    2000-01-01

    A cooler-humidifier plate for use in a proton exchange membrane (PEM) fuel cell stack assembly is provided. The cooler-humidifier plate combines functions of cooling and humidification within the fuel cell stack assembly, thereby providing a more compact structure, simpler manifolding, and reduced reject heat from the fuel cell. Coolant on the cooler side of the plate removes heat generated within the fuel cell assembly. Heat is also removed by the humidifier side of the plate for use in evaporating the humidification water. On the humidifier side of the plate, evaporating water humidifies reactant gas flowing over a moistened wick. After exiting the humidifier side of the plate, humidified reactant gas provides needed moisture to the proton exchange membranes used in the fuel cell stack assembly. The invention also provides a fuel cell plate that maximizes structural support within the fuel cell by ensuring that the ribs that form the boundaries of channels on one side of the plate have ends at locations that substantially correspond to the locations of ribs on the opposite side of the plate.

  19. The mechanical benefit of medial support screws in locking plating of proximal humerus fractures.

    Directory of Open Access Journals (Sweden)

    Wen Zhang

    Full Text Available BACKGROUND: The purpose of this study was to evaluate the biomechanical advantages of medial support screws (MSSs in the locking proximal humeral plate for treating proximal humerus fractures. METHODS: Thirty synthetic left humeri were randomly divided into 3 subgroups to establish two-part surgical neck fracture models of proximal humerus. All fractures were fixed with a locking proximal humerus plate. Group A was fixed with medial cortical support and no MSSs; Group B was fixed with 3 MSSs but without medial cortical support; Group C was fixed with neither medial cortical support nor MSSs. Axial compression, torsional stiffness, shear stiffness, and failure tests were performed. RESULTS: Constructs with medial support from cortical bone showed statistically higher axial and shear stiffness than other subgroups examined (P<0.0001. When the proximal humerus was not supported by medial cortical bone, locking plating with medial support screws exhibited higher axial and torsional stiffness than locking plating without medial support screws (P ≤ 0.0207. Specimens with medial cortical bone failed primarily by fracture of the humeral shaft or humeral head. Specimens without medial cortical bone support failed primarily by significant plate bending at the fracture site followed by humeral head collapse or humeral head fracture. CONCLUSIONS: Anatomic reduction with medial cortical support was the stiffest construct after a simulated two-part fracture. Significant biomechanical benefits of MSSs in locking plating of proximal humerus fractures were identified. The reconstruction of the medial column support for proximal humerus fractures helps to enhance mechanical stability of the humeral head and prevent implant failure.

  20. Augmented reality based real-time subcutaneous vein imaging system.

    Science.gov (United States)

    Ai, Danni; Yang, Jian; Fan, Jingfan; Zhao, Yitian; Song, Xianzheng; Shen, Jianbing; Shao, Ling; Wang, Yongtian

    2016-07-01

    A novel 3D reconstruction and fast imaging system for subcutaneous veins by augmented reality is presented. The study was performed to reduce the failure rate and time required in intravenous injection by providing augmented vein structures that back-project superimposed veins on the skin surface of the hand. Images of the subcutaneous vein are captured by two industrial cameras with extra reflective near-infrared lights. The veins are then segmented by a multiple-feature clustering method. Vein structures captured by the two cameras are matched and reconstructed based on the epipolar constraint and homographic property. The skin surface is reconstructed by active structured light with spatial encoding values and fusion displayed with the reconstructed vein. The vein and skin surface are both reconstructed in the 3D space. Results show that the structures can be precisely back-projected to the back of the hand for further augmented display and visualization. The overall system performance is evaluated in terms of vein segmentation, accuracy of vein matching, feature points distance error, duration times, accuracy of skin reconstruction, and augmented display. All experiments are validated with sets of real vein data. The imaging and augmented system produces good imaging and augmented reality results with high speed.

  1. Scaling of heat transfer augmentation due to mechanical distortions in hypervelocity boundary layers

    Science.gov (United States)

    Flaherty, W.; Austin, J. M.

    2013-10-01

    We examine the response of hypervelocity boundary layers to global mechanical distortions due to concave surface curvature. Surface heat transfer and visual boundary layer thickness data are obtained for a suite of models with different concave surface geometries. Results are compared to predictions using existing approximate methods. Near the leading edge, good agreement is observed, but at larger pressure gradients, predictions diverge significantly from the experimental data. Up to a factor of five underprediction is reported in regions with greatest distortion. Curve fits to the experimental data are compared with surface equations. We demonstrate that reasonable estimates of the laminar heat flux augmentation may be obtained as a function of the local turning angle for all model geometries, even at the conditions of greatest distortion. This scaling may be explained by the application of Lees similarity. As a means of introducing additional local distortions, vortex generators are used to impose streamwise structures into the boundary layer. The response of the large scale vortices to an adverse pressure gradient is investigated. Surface streak evolution is visualized over the different surface geometries using fast response pressure sensitive paint. For a flat plate baseline case, heat transfer augmentation at similar levels to turbulent flow is measured. For the concave geometries, increases in heat transfer by factors up to 2.6 are measured over the laminar values. The scaling of heat transfer with turning angle that is identified for the laminar boundary layer response is found to be robust even in the presence of the imposed vortex structures.

  2. Theroretical modelling of the plate-tubes coupling in the hydroelasticity of the perforated plates

    International Nuclear Information System (INIS)

    Dzhupanov, V.A.; Manoach, E.S.

    1983-01-01

    In the previous investigations on the perforated plate hydroelasticity the problem of the plates-tubes-liquid interaction in the process of the general structural vibration is stated. But the interaction of the vibrating plates with the tubes, passing through them, is taken into account considering the tubes only as absolutely rigid supports. This is one of the possible technical realizations. In the present article the case when the tubes are taking part in the plate motion (vibration) is studied. Two circular perforated plates are supported by the absolutely rigid wall of the modelled roundcircular reactor barrel. The distance between the plates is given. They are connected by tubes, passing through, and clamped into the perforation holes. The plates and the tubes are made by any elastic HOOKIAN material. The volume between the two plates and outwardly to the tubes, but intrinsically of the barrel is filled by ideal, compressible and heavy liquid. Evidently the liquid volume is multiconnected one. The free vibration of the whole system is considered with the purposes: i) to give a theoretical model of the plates-tubes-liquid interaction including governing equations and boundary conditions; ii) to trace the solution of the eigen-value problem for the modelled structure; iii) to underline the engineering sides of the modelling process. (orig./GL)

  3. Virtual, augmented reality and serious games for healthcare

    CERN Document Server

    Jain, Lakhmi; Anderson, Paul

    2014-01-01

    There is a tremendous interest among researchers for the development of virtual, augmented reality and games technologies due to their widespread applications in medicine and healthcare. To date the major applications of these technologies include medical simulation, telemedicine, medical and healthcare training, pain control, visualisation aid for surgery, rehabilitation in cases such as stroke, phobia, and trauma therapies. Many recent studies have identified the benefits of using Virtual Reality, Augmented Reality, or serious games in a variety of medical applications.   This research volume on Virtual, Augmented Reality and Serious Games for Healthcare 1 offers an insightful introduction to the theories, development and applications of virtual, augmented reality and digital games technologies in medical and clinical settings and healthcare in general. It is divided into six sections: section one presents a selection of applications in medical education and healthcare management; Section two relates to th...

  4. An Integrative Introduction to Human Augmentation Science

    OpenAIRE

    Alicea, Bradly

    2018-01-01

    Human Augmentation (HA) spans several technical fields and methodological approaches, including Experimental Psychology, Human-Computer Interaction, Psychophysiology, and Artificial Intelligence. Augmentation involves various strategies for optimizing and controlling cognitive states, which requires an understanding of biological plasticity, dynamic cognitive processes, and models of adaptive systems. As an instructive lesson, we will explore a few HA-related concepts and outstanding issues. ...

  5. Medical imaging and augmented reality. Proceedings

    International Nuclear Information System (INIS)

    Dohi, Takeyoshi; Sakuma, Ichiro; Liao, Hongen

    2008-01-01

    This book constitutes the refereed proceedings of the 4th International Workshop on Medical Imaging and Augmented Reality, MIAR 2008, held in Tokyo, Japan, in August 2008. The 44 revised full papers presented together with 3 invited papers were carefully reviewed and selected from 90 submissions. The papers are organized in topical sections on surgical planning and simulation, medical image computing, image analysis, shape modeling and morphometry, image-guided robotics, image-guided intervention, interventional imaging, image registration, augmented reality, and image segmentation. (orig.)

  6. Medical imaging and augmented reality. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Dohi, Takeyoshi [Tokyo Univ. (Japan). Dept. of Mechano-Informatics; Sakuma, Ichiro [Tokyo Univ. (Japan). Dept. of Precision Engineering; Liao, Hongen (eds.) [Tokyo Univ. (Japan). Dept. of Bioengineering

    2008-07-01

    This book constitutes the refereed proceedings of the 4th International Workshop on Medical Imaging and Augmented Reality, MIAR 2008, held in Tokyo, Japan, in August 2008. The 44 revised full papers presented together with 3 invited papers were carefully reviewed and selected from 90 submissions. The papers are organized in topical sections on surgical planning and simulation, medical image computing, image analysis, shape modeling and morphometry, image-guided robotics, image-guided intervention, interventional imaging, image registration, augmented reality, and image segmentation. (orig.)

  7. Cognitive Cost of Using Augmented Reality Displays.

    Science.gov (United States)

    Baumeister, James; Ssin, Seung Youb; ElSayed, Neven A M; Dorrian, Jillian; Webb, David P; Walsh, James A; Simon, Timothy M; Irlitti, Andrew; Smith, Ross T; Kohler, Mark; Thomas, Bruce H

    2017-11-01

    This paper presents the results of two cognitive load studies comparing three augmented reality display technologies: spatial augmented reality, the optical see-through Microsoft HoloLens, and the video see-through Samsung Gear VR. In particular, the two experiments focused on isolating the cognitive load cost of receiving instructions for a button-pressing procedural task. The studies employed a self-assessment cognitive load methodology, as well as an additional dual-task cognitive load methodology. The results showed that spatial augmented reality led to increased performance and reduced cognitive load. Additionally, it was discovered that a limited field of view can introduce increased cognitive load requirements. The findings suggest that some of the inherent restrictions of head-mounted displays materialize as increased user cognitive load.

  8. Modeling of parallel-plate regenerators with non-uniform plate distributions

    DEFF Research Database (Denmark)

    Jensen, Jesper Buch; Engelbrecht, Kurt; Bahl, Christian Robert Haffenden

    2010-01-01

    plate spacing distributions are presented in order to understand the impact of spacing non-uniformity. Simulations of more realistic distributions where the plate spacings follow normal distributions are then discussed in order to describe the deviation of the performance of a regenerator relative...

  9. Adaptive multimodal interaction in mobile augmented reality: A conceptual framework

    Science.gov (United States)

    Abidin, Rimaniza Zainal; Arshad, Haslina; Shukri, Saidatul A'isyah Ahmad

    2017-10-01

    Recently, Augmented Reality (AR) is an emerging technology in many mobile applications. Mobile AR was defined as a medium for displaying information merged with the real world environment mapped with augmented reality surrounding in a single view. There are four main types of mobile augmented reality interfaces and one of them are multimodal interfaces. Multimodal interface processes two or more combined user input modes (such as speech, pen, touch, manual gesture, gaze, and head and body movements) in a coordinated manner with multimedia system output. In multimodal interface, many frameworks have been proposed to guide the designer to develop a multimodal applications including in augmented reality environment but there has been little work reviewing the framework of adaptive multimodal interface in mobile augmented reality. The main goal of this study is to propose a conceptual framework to illustrate the adaptive multimodal interface in mobile augmented reality. We reviewed several frameworks that have been proposed in the field of multimodal interfaces, adaptive interface and augmented reality. We analyzed the components in the previous frameworks and measure which can be applied in mobile devices. Our framework can be used as a guide for designers and developer to develop a mobile AR application with an adaptive multimodal interfaces.

  10. Highly conductive composites for fuel cell flow field plates and bipolar plates

    Science.gov (United States)

    Jang, Bor Z; Zhamu, Aruna; Song, Lulu

    2014-10-21

    This invention provides a fuel cell flow field plate or bipolar plate having flow channels on faces of the plate, comprising an electrically conductive polymer composite. The composite is composed of (A) at least 50% by weight of a conductive filler, comprising at least 5% by weight reinforcement fibers, expanded graphite platelets, graphitic nano-fibers, and/or carbon nano-tubes; (B) polymer matrix material at 1 to 49.9% by weight; and (C) a polymer binder at 0.1 to 10% by weight; wherein the sum of the conductive filler weight %, polymer matrix weight % and polymer binder weight % equals 100% and the bulk electrical conductivity of the flow field or bipolar plate is at least 100 S/cm. The invention also provides a continuous process for cost-effective mass production of the conductive composite-based flow field or bipolar plate.

  11. The Mobility and Dispersal of Augmented Gravel in Upland Channels: a Knowledge-limited Practise in Supply-limited Channels

    Science.gov (United States)

    Downs, P. W.; Gilvear, D. J.

    2017-12-01

    Most river restoration research has been directed at rivers in the highly populated alluvial lowlands: significantly less is known about effectively rehabilitating upland channels, in part because the dynamics of sediment transfer are less well understood. Upland gravel augmentation is thus both a somewhat unproven method for rehabilitating degraded aquatic habitats in sediment-poor reaches, but also a natural experiment in better understanding sediment dynamics in steep, hydraulically-complex river channels. Monitoring on the River Avon in SW England since Water Year (WY) 2015 uses seismic impact plates, RFID-tagged particles and detailed channel bed mapping to establish the mobility rates of augmented particles, their dispersal distances and settling locations relative to flows received. Particles are highly, and equally, mobile: in WY2015, 17 sub-bankfull flows moved at least 60% of augmented particles with volumetric movement non-linearly correlated to flow energy but not to particle size. Waning rates of transport over the year suggest supply limitations. This relationship breaks down early in WY2017 where a two-year flow event moved 40% of the particles in just two months - confounding factors may include particle mass differences and particle supplies from upstream. Median particle travel distances correlate well to energy applied and suggest a long-tailed fan of dispersal with supplemental controls including channel curvature, boulder presence and stream power. Locally, particles are deposited preferentially around boulders and in sheltered river margins but also perched in clusters above the low-flow channel. High tracer mobility makes median transport distances highly dependent on the survey length - in WY2017 some particles travelled 300 m in a 3-month period that included the two-year flood event. Further, in WY2017 median transport distance as a function of volumetric transport suggested significant transport beyond the target reach. The observed

  12. Primary DNA damage in chrome-plating workers.

    Science.gov (United States)

    Gambelunghe, A; Piccinini, R; Ambrogi, M; Villarini, M; Moretti, M; Marchetti, C; Abbritti, G; Muzi, G

    2003-06-30

    In order to evaluate the primary DNA damage due to occupational exposure to chromium (VI), DNA strand-breaks and apoptosis in peripheral lymphocytes were measured in a group of 19 chrome-plating workers. DNA strand-breaks was assessed by alkaline (pH>13) single-cell microgel electrophoresis ('comet') assay, while apoptosis was measured by flow-cytometry after propidium iodide staining of the cells. Concentrations of chromium in urine, erythrocytes and lymphocytes were investigated as biological indicators of exposure. A group of 18 hospital workers (control group I) and another 20 university personnel (control group II) without exposure to chromium were also studied as controls. The results of the study show that chrome-plating workers have higher levels of chromium in urine, erythrocytes and lymphocytes than unexposed workers. Comet tail moment values, assumed as index of DNA damage, are increased in chromium-exposed workers and results are significantly correlated to chromium lymphocyte concentrations. No difference emerged in the percentage of apoptotic nuclei in exposed and unexposed workers. The study confirms that measurements of chromium in erythrocytes and lymphocytes may provide useful information about recent and past exposure to hexavalent chromium at the workplace. The increase in DNA strand-breaks measured by comet assay suggests this test is valid for the biological monitoring of workers exposed to genotoxic compounds such as chromium (VI).

  13. A Systematic Review of Pliance, Tracking, and Augmenting

    NARCIS (Netherlands)

    Kissi, Ama; Hughes, Sean; Mertens, Gaëtan; Barnes-Holmes, Dermot; De Houwer, Jan; Crombez, Geert

    Within relational frame theory, a distinction has been made between three types of rule-governed behavior known as pliance, tracking, and augmenting. This review examined whether there is support for the concepts of pliance, tracking, and augmenting in the experimental analysis of behavior; whether

  14. Ni-based amorphous alloy-coating for bipolar plate of PEM fuel cell by electrochemical plating

    International Nuclear Information System (INIS)

    Yamaura, S; Kim, S C; Inoue, A

    2013-01-01

    In this study, the Ni-Cr-P amorphous alloy-coated bipolar plates were produced by electro-plating on the Cu base plates with a flow field. The power generation tests of a single fuel cell with those Ni-Cr-P bipolar plates were conducted at 353 K. It was found that the single fuel cell with those Ni-Cr-P bipolar plates showed excellent I-V performance as well as that with the carbon graphite bipolar plates. It was also found that the single cell with those Ni-Cr-P bipolar plates showed better I-V performance than that with the Ni-P amorphous alloy-coated bipolar plates. Furthermore, the long-time operation test was conducted for 440 h with those Ni-Cr-P bipolar plates at the constant current density of 200 mA·cm −2 . As a result, it was found that the cell voltage gradually decreased at the beginning of the measurement before 300 h and then the voltage was kept constant after 300 h.

  15. Introduction to Mobile Augmented Reality Development in Unity

    Directory of Open Access Journals (Sweden)

    Jacob W. Greene

    2016-07-01

    Full Text Available This lesson serves as an introduction to creating mobile augmented reality applications. Augmented reality (AR can be defined as the overlaying of digital content (images, video, text, sound, etc. onto physical objects or locations, and it is typically experienced by looking through the camera lens of an electronic device such as a smartphone, tablet, or optical head-mounted display (e.g. Microsoft Hololens. Although AR is a cutting-edge, complex technology, there are a number of user-friendly platforms that allow people with no previous coding experience to create compelling augmented reality experiences.

  16. Gunner Goggles: Implementing Augmented Reality into Medical Education.

    Science.gov (United States)

    Wang, Leo L; Wu, Hao-Hua; Bilici, Nadir; Tenney-Soeiro, Rebecca

    2016-01-01

    There is evidence that both smartphone and tablet integration into medical education has been lacking. At the same time, there is a niche for augmented reality (AR) to improve this process through the enhancement of textbook learning. Gunner Goggles is an attempt to enhance textbook learning in shelf exam preparatory review with augmented reality. Here we describe our initial prototype and detail the process by which augmented reality was implemented into our textbook through Layar. We describe the unique functionalities of our textbook pages upon augmented reality implementation, which includes links, videos and 3D figures, and surveyed 24 third year medical students for their impression of the technology. Upon demonstrating an initial prototype textbook chapter, 100% (24/24) of students felt that augmented reality improved the quality of our textbook chapter as a learning tool. Of these students, 92% (22/24) agreed that their shelf exam review was inadequate and 19/24 (79%) felt that a completed Gunner Goggles product would have been a viable alternative to their shelf exam review. Thus, while students report interest in the integration of AR into medical education test prep, future investigation into how the use of AR can improve performance on exams is warranted.

  17. AUGMENTED REALITY AS AN EXCITING ONLINE EXPERIENCE: IS IT REALLY BENEFICIAL FOR BRANDS?

    Directory of Open Access Journals (Sweden)

    Ezgi Eyüboğlu

    2011-01-01

    Full Text Available The present research aims to look at the ways in wh ich Augmented Reality beneficial for brands to create positive brand perc eption, intention of purchase and positive word of mouth. Based on the aims of this r esearch paper and the study of Bluearca and Tamarjan (2010, five measures of perc eived value have been chosen- enhancing convenience, influencing enjoymen t, relevancy of idea, ease of interaction and WOM. Focus group is the method for this study because Augmented Reality application is a very new applica tion in Turkey so there is little prior knowledge and the range of responses l ikely to emerge. Focus groups have the ability to provide us with data not obtain able through paper and pencil self-report measures or observational measures. In areas of study in which little is known, focus groups may be an appropriate place to begin (Byers and Wilcox, 1991: 65. This paper explores the ways how can brands use AR application for their own beneficence. First time exposing this kind of inter active application, consumers’ first impressions, feelings and experiences will be valuable for Turkish brands which might prefer to engage their customers more c losely in future. Banana Flame is the brand chosen for this study because th ere is no Turkish brand using this application properly. Through this study, peop le’s understanding about AR technologies will be able to revealed and those inf ormation will lead Turkish brands developing experiential value and positive a ttitude in minds of their customers. The lack of Turkish brands using this application p roperly caused to choose a foreign brand (Banana Flame which is an Online Fas hion Boutique and first online retailer to integrate Augmented Reality thro ughout entire site in U.S.A. For this reason, it was assumed that Banana Flame has n o brand awareness between young Turkish consumers. Owing to the fact that Ban ana Flame is a women’s fashion brand, focus group included 18-30 years of

  18. Tantalum acetabular augments in one-stage exchange of infected total hip arthroplasty: a case-control study.

    Science.gov (United States)

    Klatte, Till Orla; Kendoff, Daniel; Sabihi, Reza; Kamath, Atul F; Rueger, Johannes M; Gehrke, Thorsten

    2014-07-01

    During the one-stage exchange procedure for periprosthetic joint infection (PJI) after total hip arthroplasty (THA), acetabular defects challenge reconstructive options. Porous tantalum augments are an established tool for addressing acetabular destruction in aseptic cases, but their utility in septic exchange is unknown. This retrospective case-control study presents the initial results of tantalum augmentation during one-stage exchange for PJI. Primary endpoints were rates of re-infection and short-term complications associated with this technique. Study patients had no higher risk of re-infection with equivalent durability at early follow-up with a re-infection rate in both groups of 4%. In conclusion, tantalum augments are a viable option for addressing acetabular defects in one-stage exchange for septic THA. Further study is necessary to assess long-term durability when compared to traditional techniques for acetabular reconstruction. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. [Comparative analysis of one- and two-stage augmentation urethroplasty with dorsal INLAY buccal graft for extended stricturesof spongious urethra].

    Science.gov (United States)

    Kogan, M I; Glukhov, V P; Mitusov, V V; Krasulin, V V; Ilyash, A V

    2018-03-01

    Urethral reconstructive surgery is in constant development. At present, reconstructive urethroplasty with buccal mucosa is increasingly being used. The study aimed to compare the results of a one- and two-stage augmentation urethroplasty with dorsal inlay buccal graft for strictures of the spongious urethra. The study comprised 72 patients aged 19-64 with urethral strictures 3-18 cm long. In 34 (47.2%) patients, the stricture was localized in the penile urethra, in 30 patients (41.6%) in the penile-bulbous urethra and in 8 patients (11%) in the bulbous urethra. All patients underwent augmentation urethroplasty with dorsal inlay buccal graft. The results were evaluated separately in 55 (76.4%, group 1) and 17 (23.6%, group 2) patients who underwent one-stage and two-stage surgery, respectively. The incidence rate of early postoperative complications was higher after one-stage (23.6%) compared two-stage surgery (11.8%) (purethroplasty with dorsal inlay buccal graft was achieved in 88.9% of patients; treatment effectiveness in the group 1 was 89.1%, in the group 2 - 88.2% (p>0.05). The final effectiveness of the operation, achieved with the use of additional surgical interventions, is estimated at 98.6%. The results of augmentation urethroplasty with dorsal inlay buccal graft do not depend on the number of stages, but fewer complications accompany two-stage surgery.

  20. Observation and analysis of a classroom teaching and learning practice based on augmented reality and serious games on mobile platforms

    Directory of Open Access Journals (Sweden)

    Sylvie Barma

    2015-06-01

    Full Text Available This qualitative research is part of a learning effort to better understand how serious games are exploited in a science education context. The research team examined this issue by focusing on augmented reality as a technological innovation imbedded on a tablet. Given the current state of knowledge related to serious games and augmented reality, and given the fact that its use in the context of teaching/learning is not extended, this paper focuses on an initial exploration of how a new teaching practice involving a serious game based on an interactive augmented reality solution would impact on students in a physics class. A Design Based Research methodology was applied in a real‑world context within a college‑level physics class. Two conceptual tests containing ten questions on spatial notions regarding electromagnetic fields were administered to two control groups and two groups using the proposed serious game. The latter groups were administrated a game evaluation questionnaire as well. Thematic interpretation of students written responses to the evaluation questionnaire as well as the lessons and observations we derived from the in-class experimentation are provided and discussed in the paper.

  1. Augmentative biological control of arthropods in Latin America

    NARCIS (Netherlands)

    Lenteren, van J.C.; Bueno, V.H.P.

    2003-01-01

    Augmentative forms of biological control, where natural enemies are periodically introduced, are applied over large areas in various cropping systems in Latin America. About 25% of the world area under augmentative control is situated in this region. Well-known examples are the use of species of the

  2. Track plate enclosures: Box designs affecting attractiveness to riparian mammals

    Science.gov (United States)

    Loukmas, J.J.; Mayack, D.T.; Richmond, M.E.

    2003-01-01

    We examined the efficacy of four track plate enclosure designs for monitoring the abundance of small and medium-sized mammals along 10 streams in New York State. Box size and clarity of view through the box were evaluated as factors affecting visitation. We checked track plate stations weekly from September 1999 to March 2000. Eleven mammalian species or species groups visited the track plate stations. Raccoons (Procyon lotor) (P = 0.020) and feral cats (Felis catus) (P = 0.008) visited large enclosures significantly more than small enclosures. Feral cats visited clear-view enclosures significantly more than obstructed-view enclosures (P = 0.025). Enclosure size and view did not significantly affect visitation by other species; however, a large box with a clear view was the most effective design.

  3. Augmented reality mobile application for overlaying images on textiles

    OpenAIRE

    Brinza, Veronica

    2016-01-01

    Augmented reality is one the relatively new and fast growing branches in modern informatics. It incorporates in simple people lives on a lot of different levels. It can be used everywhere starting from the simple checking of your email and ending up with a complex augmented reality video games or augmented reality learning. From the ancient times actors tried to immerse the spectators in world of the performance using decoration and costumed. In XVIII – XIX centuries pictures w...

  4. Augmented reality tools and learning practice in mobile-learning

    OpenAIRE

    Figueiredo, Mauro; Gomes, José; Gomes, Cristina; Lopes, João

    2014-01-01

    There are many augmented reality (AR) applications available that can be used to create educational contents for these mobile devices. This paper surveys the most popular augmented reality applications and we select AR eco-systems to be used in daily teaching activities which are user friendly, do not require programming skills and are free. Different augmented reality technologies are explored in this paper to create teaching activities with animations, videos and other information to be sho...

  5. Augmented reality aiding collimator exchange at the LHC

    International Nuclear Information System (INIS)

    Martínez, Héctor; Fabry, Thomas; Laukkanen, Seppo; Mattila, Jouni; Tabourot, Laurent

    2014-01-01

    Novel Augmented Reality techniques have the potential to have a large positive impact on the way remote maintenance operations are carried out in hazardous areas, e.g. areas where radiation doses that imply careful planning and optimization of maintenance operations are present. This paper describes an Augmented Reality strategy, system and implementation for aiding the remote collimator exchange in the LHC, currently the world's largest and highest-energy particle accelerator. The proposed system relies on marker detection and multi-modal augmentation in real-time. A database system has been used to ensure flexibility. The system has been tested in a mock-up facility, showing real time performance and great potential for future use in the LHC. The technical-scientific difficulties identified during the development of the system and the proposed solutions described in this paper may help the development of future Augmented Reality systems for remote handling in scientific facilities

  6. Augmented reality aiding collimator exchange at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Martínez, Héctor, E-mail: hector.martinez@sensetrix.com [SenseTrix, PL 20 FI-00101 Helsinki (Finland); Fabry, Thomas [European Organization for Nuclear Research, CERN, CH-1211 Genève 23 (Switzerland); Laukkanen, Seppo [SenseTrix, PL 20 FI-00101 Helsinki (Finland); Mattila, Jouni [Tampere University of Technology, PO Box 527, FI-33101 Tampere (Finland); Tabourot, Laurent [SYMME, Université de Savoie, Polytech Annecy-Chambéry, 5 chemin de Bellevue, 74944 Annecy le Vieux (France)

    2014-11-01

    Novel Augmented Reality techniques have the potential to have a large positive impact on the way remote maintenance operations are carried out in hazardous areas, e.g. areas where radiation doses that imply careful planning and optimization of maintenance operations are present. This paper describes an Augmented Reality strategy, system and implementation for aiding the remote collimator exchange in the LHC, currently the world's largest and highest-energy particle accelerator. The proposed system relies on marker detection and multi-modal augmentation in real-time. A database system has been used to ensure flexibility. The system has been tested in a mock-up facility, showing real time performance and great potential for future use in the LHC. The technical-scientific difficulties identified during the development of the system and the proposed solutions described in this paper may help the development of future Augmented Reality systems for remote handling in scientific facilities.

  7. Transaxillary Endoscopic Breast Augmentation

    Directory of Open Access Journals (Sweden)

    Hyung-Bo Sim

    2014-09-01

    Full Text Available The axillary technique is the most popular approach to breast augmentation among Korean women. Transaxillary breast augmentation is now conducted with sharp electrocautery dissection under direct endoscopic vision throughout the entire process. The aims of this method are clear: both a bloodless pocket and a sharp non-traumatic dissection. Round textured or anatomical cohesive gel implants have been used to make predictable well-defined inframammary creases because textured surface implants demonstrated a better stability attributable to tissue adherence compared with smooth surface implants. The axillary endoscopic technique has greatly evolved, and now the surgical results are comparable to those with the inframammary approach. The author feels that this technique is an excellent choice for young patients with an indistinct or absent inframammary fold, who do not want a scar in the aesthetic unit of their chest.

  8. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal ... Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook ...

  9. Create Your Plate

    Medline Plus

    Full Text Available ... Meals Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with ... Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart-Healthy ...

  10. Create Your Plate

    Medline Plus

    Full Text Available ... of the differences in types of vegetables. When creating your plate at home, remember that half of ... effective for both managing diabetes and losing weight. Creating your plate lets you still choose the foods ...

  11. Create Your Plate

    Medline Plus

    Full Text Available ... Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type 1 Diabetes Get Started Safely Get And ... Plate Create Your Plate is a simple and effective way to manage your blood glucose levels and ...

  12. Create Your Plate

    Medline Plus

    Full Text Available ... foods you want, but changes the portion sizes so you are getting larger portions of non-starchy ... plate. Then on one side, cut it again so you will have three sections on your plate. ...

  13. Parathyroid Hormone (1-34 Might Not Improve Early Bone Healing after Sinus Augmentation in Healthy Rabbits

    Directory of Open Access Journals (Sweden)

    Jisun Huh

    2017-01-01

    Full Text Available Purpose. This study evaluated the effect of administering intermittent parathyroid hormone [PTH (1-34, henceforth PTH] on the early-stage bone healing of maxillary sinus augmentation in healthy rabbits. Materials and Methods. Bovine bone mineral was grafted on the sinuses of 20 female New Zealand white rabbits. The animals were randomly divided into two groups, PTH (n=10 or saline (n=10, in which either PTH or saline was injected subcutaneously 5 days a week for 2 weeks. Half of the animals in each group were killed at 2 weeks postoperatively and the other half were killed at 4 weeks postoperatively. The dosage of PTH was 10 μg/kg/day. Radiographic and histomorphometric analyses were performed. Result. The new bone area (NBA did not differ significantly between the PTH and saline groups. The NBA in the PTH group in the total augmented area and in the demarcated window, center, and Schneiderian membrane regions increased significantly from 2 to 4 weeks. The number of osteoclasts decreased significantly from 2 to 4 weeks in both groups, with no difference between the two groups. Conclusion. Intermittent PTH might not stimulate new bone formation in healthy rabbits during the first 4 weeks of healing.

  14. Elastic stability of thick auxetic plates

    International Nuclear Information System (INIS)

    Lim, Teik-Cheng

    2014-01-01

    Auxetic materials and structures exhibit a negative Poisson’s ratio while thick plates encounter shear deformation, which is not accounted for in classical plate theory. This paper investigates the effect of a negative Poisson’s ratio on thick plates that are subjected to buckling loads, taking into consideration the shear deformation using Mindlin plate theory. Using a highly accurate shear correction factor that allows for the effect of Poisson’s ratio, the elastic stability of circular and square plates are evaluated in terms of dimensionless parameters, namely the Mindlin-to-Kirchhoff critical buckling load ratio and Mindlin critical buckling load factors. Results for thick square plates reveal that both parameters increase as the Poisson’s ratio becomes more negative. In the case of thick circular plates, the Mindlin-to-Kirchhoff critical buckling load ratios and the Mindlin critical buckling load factors increase and decrease, respectively, as the Poisson’s ratio becomes more negative. The results obtained herein show that thick auxetic plates behave as thin conventional plates, and therefore suggest that the classical plate theory can be used to evaluate the elastic stability of thick plates if the Poisson’s ratio of the plate material is sufficiently negative. The results also suggest that materials with highly negative Poisson’s ratios are recommended for square plates, but not circular plates, that are subjected to buckling loads. (paper)

  15. Neutron imaging plates

    International Nuclear Information System (INIS)

    Niimura, Nobuo

    1995-01-01

    Imaging plates have been used in the field of medical diagnosis since long ago, but their usefulness was verified as the two-dimensional detector for analyzing the X-ray crystalline structure of high bio molecules like protein, and they have contributed to the remarkable progress in this field. The great contribution is due to the excellent features, such as the detection efficiency of about 100%, the positional resolution smaller than 0.2 mm, the dynamic range of five digits, and the area of several hundreds mm square. The neutron imaging plates have not yet obtained the sufficient results. It was planned to construct the neutron diffractometer for biological matters, and to put imaging plate neutron detectors (IP-ND) to practical use as the detector. The research on the development of IP-NDs was carried out, and the IPp-NDs having the performance comparable with that for X-ray were able to be produced. Imaging plates are the integral type two-dimensional radiation detector using photostimulated luminescence matters, and their principle is explained. As to neutron imaging plates, the converter, neutron detection efficiency and the flight of secondary particles in photo-stimulated luminescence matters are described. As for the present state of development of neutron imaging plates, the IP-NDs made for trial, the dynamic range, the positional resolution, the detection efficiency and the kinds of converters, and the application of IP-NDs are reported. (K.I.)

  16. Towards stacked zone plates

    International Nuclear Information System (INIS)

    Werner, S; Rehbein, S; Guttman, P; Heim, S; Schneider, G

    2009-01-01

    Fresnel zone plates are the key optical elements for soft and hard x-ray microscopy. For short exposure times and minimum radiation load of the specimen the diffraction efficiency of the zone plate objectives has to be maximized. As the efficiency strongly depends on the height of the diffracting zone structures the achievable aspect ratio of the nanostructures determines these limits. To reach aspect ratios ≥ 20:1 for high efficient optics we propose to superimpose zone plates on top of each other. With this multiplication approach the final aspect ratio is only limited by the number of stacked zone plate layers. For the stack process several nanostructuring process steps have to be developed and/or improved. Our results show for the first time two layers of zone plates stacked on top of each other.

  17. A histologic, histomorphometric, and radiographic comparison between two complexes of CenoBoen/CenoMembrane and Bio-Oss/Bio-Gide in lateral ridge augmentation: A clinical trial.

    Science.gov (United States)

    Amoian, Babak; Moudi, Ehsan; Majidi, Maryam Seyed; Ali Tabatabaei, S M

    2016-09-01

    Several grafting materials have been used for alveolar ridge augmentation. The literature lacks researches to compare CenoBone to other grafting materials. The aim of this study was to compare CenoBone/CenoMembrane complex to Bio-Oss/Bio-Gide complex in lateral alveolar bone augmentation in terms of radiographic, histologic, and histomorphometric parameters. In this randomized controlled trial, ten patients who needed lateral ridge augmentation were selected and augmentations were done using either of CenoBone/CenoMembrane or Bio-Oss/Bio-Gide complexes. In the re-entry surgery in 6 months following augmentation, core biopsies were taken and clinical, radiographic, histologic, and histomorphometric evaluations were performed. No statistically significant difference was seen between groups except for the number of blood vessels and percentage of residual graft materials. CenoBone seems to present a comparable lateral ridge augmentation to Bio-Oss in.

  18. Transforming Polar Research with Google Glass Augmented Reality (Invited)

    Science.gov (United States)

    Ruthkoski, T.

    2013-12-01

    Augmented reality is a new technology with the potential to accelerate the advancement of science, particularly in geophysical research. Augmented reality is defined as a live, direct or indirect, view of a physical, real-world environment whose elements are augmented (or supplemented) by computer-generated sensory input such as sound, video, graphics or GPS data. When paired with advanced computing techniques on cloud resources, augmented reality has the potential to improve data collection techniques, visualizations, as well as in-situ analysis for many areas of research. Google is currently a pioneer of augmented reality technology and has released beta versions of their wearable computing device, Google Glass, to a select number of developers and beta testers. This community of 'Glass Explorers' is the vehicle from which Google shapes the future of their augmented reality device. Example applications of Google Glass in geophysical research range from use as a data gathering interface in harsh climates to an on-site visualization and analysis tool. Early participation in the shaping of the Google Glass device is an opportunity for researchers to tailor this new technology to their specific needs. The purpose of this presentation is to provide geophysical researchers with a hands-on first look at Google Glass and its potential as a scientific tool. Attendees will be given an overview of the technical specifications as well as a live demonstration of the device. Potential applications to geophysical research in polar regions will be the primary focus. The presentation will conclude with an open call to participate, during which attendees may indicate interest in developing projects that integrate Google Glass into their research. Application Mockup: Penguin Counter Google Glass Augmented Reality Device

  19. The Effect of Alendronate on Various Graft Materials Used in Maxillary Sinus Augmentation: A Rabbit Study.

    Science.gov (United States)

    Ayranci, Ferhat; Gungormus, Metin; Omezli, Mehmet Melih; Gundogdu, Betul

    2015-12-01

    Increasing sinus pneumatization and the accompanying alveolar bone resorption complicate dental implant placement. This problem can be overcome today by raising the maxillary sinus floor with graft materials. Bisphosphonates are commonly used to accelerate the recovery of the graft materials and to prevent resorption. The purpose of this study is to investigate whether systemic administration of a bisphosphonate (alendronate) would improve new bone formation and reduce fibrous tissue formation over a 6-week follow-up in rabbits treated with two different grafting materials for maxillary sinus floor augmentation. This experimental animal study was conducted at the Experimental Medical Application and Research Center at Erzurum/ Turkey. Twelve New Zealand rabbits, each weighing between 2.7 and 3.3 kg, were used. Twenty-four maxillary sinus floor elevation operations were performed, two on each animal (n = 24). Each elevation was repaired with either deproteinized bovine bone (xenograft) or autogenous bone graft obtained from the iliac crest. Both groups were divided into 2 subgroups: saline-treated and alendronate-treated. All groups underwent the same surgical procedures and evaluation, and were sacrificed at the 6th postoperative week. Sinuses augmented with deproteinized bovine bone (xenograft) and autogenous bone graft were examined histopathologically and histomorphometrically. At 6 weeks, the bone area was significantly larger in the Xenograft-Alendronate group (33.0% ± 5.0%) than in the Xenograft-Saline group (20.8% ± 4.9%) and the bone area was significantly larger in the Autogenous-Alendronate group (43.3% ± 3.8%) than in the Autogenous-Saline group (37.5% ± 6.6%) (P = 0.001). The histomorphometric and histopathological results consistently showed that alendronate stimulated bone formation and reduced fibrous tissue formation in maxillary sinus augmentation grafts, especially in the deproteinized bovine bone group (xenograft). Alendronate may be

  20. Anisotropic elastic plates

    CERN Document Server

    Hwu, Chyanbin

    2010-01-01

    As structural elements, anisotropic elastic plates find wide applications in modern technology. The plates here are considered to be subjected to not only in plane load but also transverse load. In other words, both plane and plate bending problems as well as the stretching-bending coupling problems are all explained in this book. In addition to the introduction of the theory of anisotropic elasticity, several important subjects have are discussed in this book such as interfaces, cracks, holes, inclusions, contact problems, piezoelectric materials, thermoelastic problems and boundary element a

  1. Does Additional Biceps Augmentation Improve Rotator Cuff Healing and Clinical Outcomes in Anterior L-Shaped Rotator Cuff Tears? Clinical Comparisons With Arthroscopic Partial Repair.

    Science.gov (United States)

    Jeon, Yoon Sang; Lee, Juyeob; Kim, Rag Gyu; Ko, Young-Won; Shin, Sang-Jin

    2017-11-01

    The repair of anterior L-shaped tears is usually difficult because of the lack of anterior rotator cuff tendon to cover the footprint. The biceps tendon is usually exposed from the retracted anterolateral corner of the torn tendon and can be easily used to augment rotator cuff repair. Hypothesis/Purpose: This study compared the clinical outcomes of the biceps augmentation technique with those of partial tendon repair for the arthroscopic treatment of large anterior L-shaped rotator cuff tears to evaluate the role of additional biceps augmentation in tendon healing. We hypothesized that the biceps augmentation technique would lead to a lower rotator cuff tendon retear rate and provide satisfactory functional outcomes. Cohort study; Level of evidence, 3. This study included 64 patients with anterior L-shaped rotator cuff tears who underwent arthroscopic repair. Patients were divided into 2 groups: group A (31 patients) underwent repair of an anterior L-shaped tear combined with biceps augmentation, and group B (33 patients) had a partially repaired tendon whose footprint was exposed after repair without undue tension on the retracted tendon. Clinical evaluations were performed using the American Shoulder and Elbow Surgeons (ASES) score, Constant score, muscle strength, visual analog scale for pain, and patient satisfaction. Magnetic resonance imaging (MRI) was performed for tendon integrity at 6 months postoperatively. The mean period of follow-up was 29.1 ± 3.5 months (range, 24-40 months). The mean ASES and Constant scores significantly improved from 52.8 ± 10.6 and 43.2 ± 9.9 preoperatively to 88.2 ± 6.9 and 86.8 ± 6.2 at final follow-up in group A ( P rotation [ER]: 57.5 ± 9.9 to 86.8 ± 9.3; internal rotation [IR]: 68.1 ± 10.8 to 88.1 ± 8.4; P rotator cuff tendon on postoperative MRI. The retear rate between the 2 groups showed no significant difference ( P = .552). Regarding clinical outcomes, both groups had no significant difference in the ASES score

  2. Maxillary Sinus Floor Augmentation

    DEFF Research Database (Denmark)

    Starch-Jensen, Thomas; Jensen, Janek Dalsgaard

    2017-01-01

    , radiological and histomorphometric outcome as well as complications are presented after maxillary sinus floor augmentation applying the lateral window technique with a graft material, maxillary sinus membrane elevation without a graft material and osteotome-mediated sinus floor elevation with or without...

  3. Buckling analysis for axially compressed flat plates, structural sections, and stiffened plates reinforced with laminated composites

    Science.gov (United States)

    Viswanathan, A. V.; Soong, T.; Miller, R. E., Jr.

    1971-01-01

    A classical buckling analysis is developed for stiffened, flat plates composed of a series of linked plate and beam elements. Plates are idealized as multilayered orthotropic elements. Structural beads and lips are idealized as beams. The loaded edges of the stiffened plate are simply-supported and the conditions at the unloaded edges can be prescribed arbitrarily. The plate and beam elements are matched along their common junctions for displacement continuity and force equilibrium in an exact manner. Offsets between elements are considered in the analysis. Buckling under uniaxial compressive load for plates, sections, and stiffened plates is investigated. Buckling loads are the lowest of all possible general and local failure modes, and the mode shape is used to determine whether buckling is a local or general instability. Numerical correlations with existing analysis and test data for plates, sections, and stiffened plates including boron-reinforced structures are discussed. In general correlations are reasonably good.

  4. Create Your Plate

    Medline Plus

    Full Text Available ... In Memory In Honor Become a Member En Español Type 1 Type 2 About Us Online Community ... Page Text Size: A A A Listen En Español Create Your Plate Create Your Plate is a ...

  5. Create Your Plate

    Medline Plus

    Full Text Available ... Planning Meals Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart- ... Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart-Healthy Foods ...

  6. BAO Plate Archive Project

    Science.gov (United States)

    Mickaelian, A. M.; Gigoyan, K. S.; Gyulzadyan, M. V.; Paronyan, G. M.; Abrahamyan, H. V.; Andreasyan, H. R.; Azatyan, N. M.; Kostandyan, G. R.; Samsonyan, A. L.; Mikayelyan, G. A.; Farmanyan, S. V.; Harutyunyan, V. L.

    2017-12-01

    We present the Byurakan Astrophysical Observatory (BAO) Plate Archive Project that is aimed at digitization, extraction and analysis of archival data and building an electronic database and interactive sky map. BAO Plate Archive consists of 37,500 photographic plates and films, obtained with 2.6m telescope, 1m and 0.5m Schmidt telescopes and other smaller ones during 1947-1991. The famous Markarian Survey (or the First Byurakan Survey, FBS) 2000 plates were digitized in 2002-2005 and the Digitized FBS (DFBS, www.aras.am/Dfbs/dfbs.html) was created. New science projects have been conducted based on this low-dispersion spectroscopic material. Several other smaller digitization projects have been carried out as well, such as part of Second Byurakan Survey (SBS) plates, photographic chain plates in Coma, where the blazar ON 231 is located and 2.6m film spectra of FBS Blue Stellar Objects. However, most of the plates and films are not digitized. In 2015, we have started a project on the whole BAO Plate Archive digitization, creation of electronic database and its scientific usage. Armenian Virtual Observatory (ArVO, www.aras.am/Arvo/arvo.htm) database will accommodate all new data. The project runs in collaboration with the Armenian Institute of Informatics and Automation Problems (IIAP) and will continues during 4 years in 2015-2018. The final result will be an Electronic Database and online Interactive Sky map to be used for further research projects. ArVO will provide all standards and tools for efficient usage of the scientific output and its integration in international databases.

  7. Towards Wearable Gaze Supported Augmented Cognition

    DEFF Research Database (Denmark)

    Toshiaki Kurauchi, Andrew; Hitoshi Morimoto, Carlos; Mardanbeigi, Diako

    Augmented cognition applications must deal with the problem of how to exhibit information in an orderly, understandable, and timely fashion. Though context have been suggested to control the kind, amount, and timing of the information delivered, we argue that gaze can be a fundamental tool...... by the wearable computing community to develop a gaze supported augmented cognition application with three interaction modes. The application provides information of the person being looked at. The continuous mode updates information every time the user looks at a different face. The key activated discrete mode...

  8. Superconducting augmented rail gun (SARG)

    International Nuclear Information System (INIS)

    Homan, C.G.; Cummings, C.E.; Fowler, C.M.

    1986-01-01

    Superconducting augmentation consists of a superconducting coil operating in the persistent mode closely coupled magnetically with a normally conducting rail gun. A theoretical investigation of the effect of this system on a rail gun has shown that two benefits occur. Projectile velocities and launch efficiencies increase significantly depending on the magnetic coupling between the rail and augmentation circuits. Previous work evaluated an idealized system by neglecting energy dissipation effects. In this paper, the authors extend the analysis to include the neglected terms and show improved actual launch efficiencies for the SARG configuration. In this paper, the authors discuss details of projectile design in depth and present preliminary results of rail gun performance

  9. The Local Games Lab ABQ: Homegrown Augmented Reality

    Science.gov (United States)

    Holden, Christopher

    2014-01-01

    Experiments in the use of augmented reality games formerly required extensive material resources and expertise to implement above and beyond what might be possible within the usual educational contexts. Currently, the more common availability of hardware in these contexts and the existence of easy-to-use, general purpose augmented reality design…

  10. Complications 15 years after breast augmentation with polyacrylamide

    Directory of Open Access Journals (Sweden)

    Habib M. Ghasemi

    2015-06-01

    Full Text Available Polyacrylamide hydrogel (PAAG has been used as an injectable, permanent filler for soft-tissue augmentation for more than two decades. Several complications have been reported worldwide. In this case report, we present a woman with long-term complications 15 years after bilateral breast augmentation with PAAG injections.

  11. Pose estimation for mobile devices and augmented reality

    NARCIS (Netherlands)

    Caarls, J.

    2009-01-01

    In this thesis we introduce the reader to the field of Augmented Reality (AR) and describe aspects of an AR system. We show the current uses in treatment of phobias, games, sports and industry. We present the challenges for Optical See-Through Augmented Reality in which the real world is perceived

  12. PENGGUNAAN AUGMENTED REALITY UNTUK MENSIMULASIKAN DEKORASI RUANGAN SECARA REAL TIME

    Directory of Open Access Journals (Sweden)

    Ulva Erida Nur Rochmah

    2016-12-01

    Full Text Available Abstrak Mendekorasi ruangan merupakan kegiatan  yang memakan banyak waktu dan tenaga, terutama jika objek yang digunakan besar dan berat. Akan merepotkan jika seseorang harus menggeser setiap objek untuk menentukan letak yang sesuai. Hal ini dapat dihindari dengan menggunakan aplikasi berbasis Augmented Reality. Augmented Reality merupakan sebuah teknologi untuk menggabungkan dunia nyata dan dunia virtual dengan cara menampilkan objek-objek virtual di dunia nyata secara real time. Tujuan utama dari penelitian ini adalah untuk menciptakan suatu aplikasi Android dengan menggunakan Augmented Reality yang dapat digunakan untuk menggantikan objek nyata dengan objek virtual 3D sehingga memudahkan pengguna dalam mensimulasikan dekorasi ruangan. Aplikasi ini bekerja dengan cara memindai marker yang sudah dicetak pada selembar kertas. Jika marker telah terdeteksi, objek 3D berupa perabot akan ditampilkan di kamera aplikasi. Pengguna dapat memindah lokasi, memutar, dan mengubah ukuran objek untuk mensimulasikan tata letak ruangan. Hasil penelitian ini adalah aplikasi Android berbasis Augmented Reality yang dapat digunakan untuk mensimulasikan dekorasi ruangan secara real time. Kata Kunci: augmented reality, dekorasi, interior, marker Abstract Decorating the room is an activity that takes a lot of time and effort, especially if the object is large and heavy. It would be inconvenient if someone has to drag each object to determine the appropriate location. This problem can be avoided using an Augmented Reality-based application. Augmented reality is a technology that combine the real world and the virtual world by displaying virtual object in real world. The main purpose of this research is to create an Android application using Augmented reality  that can be used to replace the real object with virtual 3D object, making it easier for the user to simulate the decoration of the room. This application works by scanning the marker that has been printed on a

  13. Augmented reality

    OpenAIRE

    Jecha, Jakub

    2011-01-01

    This thesis is focused on a technology called Augmented reality, especially on its use in marketing. The main objective of the thesis is to define why this technology is a suitable tool for marketing and to assess its use in real conditions. This is achieved by defining specific devices and use cases of this technology in practice, whereas evaluation of its use in real enviroment is based on statistics. The contribution of the thesis is objective evaluation of this technology and provision of...

  14. Comparable clinical and radiological outcomes between skipped-level and all-level plating for open-door laminoplasty.

    Science.gov (United States)

    Cheung, Jason Pui Yin; Cheung, Prudence Wing Hang; Cheung, Amy Yim Ling; Lui, Darren; Cheung, Kenneth M C

    2018-06-01

    To compare the clinical and radiological outcomes between skipped-level and all-level plating for cervical laminoplasty. Patients with cervical spondylotic myelopathy (CSM) treated by open-door laminoplasty with minimum 2-year postoperative follow-up were included. All patients had opening from C3-6 or C3-7 and were divided into skipped-level or all-level plating groups. Japanese Orthopaedic Association (JOA) scores and canal measurements were obtained preoperatively, immediate (within 1 week) postoperatively, and at 2, 6 weeks, 3, 6 and 12 months postoperatively. Paired t test was used for comparative analysis. Receiver operating characteristic analysis was used to determine the canal expansion cutoff for spring-back closure. A total of 74 subjects were included with mean age of 66.1 ± 11.3 years at surgery. Of these, 32 underwent skipped-level plating and 42 underwent all-level plating. No significant differences were noted between the two groups at baseline and follow-up. Spring-back closure was observed in up to 50% of the non-plated levels within 3 months postoperatively. The cutoff for developing spring-back closure was 7 mm canal expansion for C3-6. No differences were observed in JOA scores and recovery rates between the two groups. None of the patients with spring-back required reoperation. There were no significant differences between skipped-level and all-level plating in terms of JOA or recovery rate, and canal diameter differences. This has tremendous impact on saving costs in CSM management as up to two plates per patient undergoing a standard C3-6 laminoplasty may be omitted instead of four plates to every level to achieve similar clinical and radiological outcomes. III. These slides can be retrieved under Electronic Supplementary Material.

  15. Create Your Plate

    Medline Plus

    Full Text Available ... Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal Planning ... Planning Meals Diabetes Meal Plans and a Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets ...

  16. Gain stabilized microchannel plates and a treatment method for microchannel plates

    International Nuclear Information System (INIS)

    1979-01-01

    Microchannel plates having increased gain and significantly improved aging characteristics are provided by forming a thin film of a cesium compound on the channel walls. In an exemplary embodiment, a suface film of cesium hydroxide is applied to the interior wall surfaces of an MCP by saturating the plate with a solution of the compound, then allowing the solvent to evaporate. The cesium hydroxide residue on the walls subsequently is converted to cesium oxide by a high temperature bake. Microchannel plates are used in image amplifiers, radiation detectors and such like equipment. (Auth.)

  17. Bottom nozzle for nuclear reactor fuel assembly having an adaptor plate and a coupled filtration plate

    International Nuclear Information System (INIS)

    Verdier, M.; Mortgat, R.

    1992-01-01

    The bottom nozzle includes an adaptor plate with openings to allow the passage of water and a filtration plate with small holes. The openings in the adaptor plate are symmetrical with regard to medians and diagonals. Within each zone, some of the openings are rectangular and some may be circular. The small holes in the filtration plate coincide with the rectangular openings in the adaptor plate

  18. Augmenting a Child's Reality: Using Educational Tablet Technology

    Science.gov (United States)

    Tanner, Patricia; Karas, Carly; Schofield, Damian

    2014-01-01

    This study investigates the classroom integration of an innovative technology, augmented reality. Although the process of adding new technologies into a classroom setting can be daunting, the concept of augmented reality has demonstrated the ability to educate students and to assist with their comprehension of a procedural task. One half of the…

  19. Comparative study of bridge plate associated to the intramedullary pin and the dynamic compression plate on the experimental osteotomy fixation of femoral in rabbits (Oryctolagus cuniculus). Clinical, radiographic, histological and scintigraphy analyses

    International Nuclear Information System (INIS)

    Borges, Natalie Ferreira

    2011-01-01

    The objectives were to benchmark and monitor the fracture healing of femoral osteotomy in rabbits after fixation with dynamic compression plate and bridge plate associated with intramedullary pin. Were used 14 New Zealand rabbits, four months old with mean weight of 3.5 pounds, from the Experimental Farm Professor Helio Barbosa of the Veterinary School of Minas Gerais Federal Univ. (UFMG). The animals were randomly divided into two groups (I and II). All rabbits underwent osteotomy across the middle third of right femur. In the group I was made to fix the osteotomy with the bridge plate (BP) associated with intramedullary pin, introduced the technique of minimal invasion. In group II, we used dynamic compression plate (DCP) via the conventional approach. Both groups were evaluated clinical, radiographic, histologic and scintigraphic findings. Clinical assessments were performed weekly until the 12 th postoperative week and radiographic examinations were performed before, immediately after, at 15, 30, 45, 60 and 90 days. The bone scintigraphy were performed before and at 20, 50 and 90 days after surgery to monitor the bone metabolism qualitatively and quantitatively. Observed perfusion and bone healing process. After 90 days of study, there was histopathologic evaluation of the osteotomized area and the insertion of screws. In the region of the osteotomy was observed predominance of trabecular bone in group I and group II, the predominance of bone osteons, compatible with the original bone. On insertion of the screws did not differ between groups and there was cortical discontinuity, little necrosis and local hemorrhage. The two types of fixation have led to consolidation within the scheduled period, maturing in early fixation with DCP fixation compared with BP. Scintigraphy demonstrated by the indices of activity and image characteristics, the process of bone healing was significantly greater in animals undergoing early fixation with DCP. (author)

  20. Corrosion and erosion monitoring in plates and pipes using constant group velocity Lamb wave inspection.

    Science.gov (United States)

    Nagy, Peter B; Simonetti, Francesco; Instanes, Geir

    2014-09-01

    Recent improvements in tomographic reconstruction techniques generated a renewed interest in short-range ultrasonic guided wave inspection for real-time monitoring of internal corrosion and erosion in pipes and other plate-like structures. Emerging evidence suggests that in most cases the fundamental asymmetric A0 mode holds a distinct advantage over the earlier market leader fundamental symmetric S0 mode. Most existing A0 mode inspections operate at relatively low inspection frequencies where the mode is highly dispersive therefore very sensitive to variations in wall thickness. This paper examines the potential advantages of increasing the inspection frequency to the so-called constant group velocity (CGV) point where the group velocity remains essentially constant over a wide range of wall thickness variation, but the phase velocity is still dispersive enough to allow accurate wall thickness assessment from phase angle measurements. This paper shows that in the CGV region the crucial issue of temperature correction becomes especially simple, which is particularly beneficial when higher-order helical modes are also exploited for tomography. One disadvantage of working at such relatively high inspection frequency is that, as the slower A0 mode becomes faster and less dispersive, the competing faster S0 mode becomes slower and more dispersive. At higher inspection frequencies these modes cannot be separated any longer based on their vibration polarization only, which is mostly tangential for the S0 mode while mostly normal for the A0 at low frequencies, as the two modes become more similar as the frequency increases. Therefore, we propose a novel method for suppressing the unwanted S0 mode based on the Poisson effect of the material by optimizing the angle of inclination of the equivalent transduction force of the Electromagnetic Acoustic Transducers (EMATs) used for generation and detection purposes. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. A retrospective study of predictive factors for effective aripiprazole augmentation of antidepressant therapy in treatment-resistant depression

    Directory of Open Access Journals (Sweden)

    Sugawara H

    2016-05-01

    Full Text Available Hiroko Sugawara,1,2 Kaoru Sakamoto,1 Tsuyoto Harada,3 Satoru Shimizu,4 Jun Ishigooka1 1Department of Psychiatry, Tokyo Women’s Medical University, 2Support Center for Women Health Care Professionals and Researchers, Tokyo Women’s Medical University, Shinjuku-ku, 3Department of Psychiatry, Tokyo Women’s Medical University Medical Center East, Arakawa-ku, 4Department of Research, Medical Research Institute, Tokyo Women’s Medical University, Shinjuku-ku, Tokyo, Japan Background: Several studies have evaluated the efficacy and tolerability of aripiprazole for augmentation of antidepressant therapy for treatment-resistant depression (TRD. Here, we investigated the efficacy of aripiprazole augmentation for TRD including both major depressive disorder and bipolar disorder and the clinical predictors of treatment efficacy in a Japanese population.  Methods: Eighty-five depressed Japanese patients who underwent aripiprazole augmentation therapy after failing to respond satisfactorily to antidepressant monotherapy were included in the study. Treatment responses were evaluated based on Clinical Global Impression Improvement scores assessed 8 weeks after initiation of aripiprazole administration. We compared demographic and diagnostic variables, psychiatric medication variables, and clinical variables between remission and nonremission groups.  Results: The aripiprazole augmentation remission rate was 36.5%. Multiple logistic regression analysis indicated that aripiprazole augmentation was significantly more effective for bipolar depression than for major depressive disorder, and both absence of comorbid anxiety disorders and current episode duration >3 months were significantly associated with the efficacy of aripiprazole augmentation.  Conclusion: Polarity of depression, comorbidity of anxiety disorders, and current episode duration may predict the efficacy of aripiprazole augmentation for TRD including both major depressive disorder and

  2. Systematic Review and Meta-Analysis of Recombinant Human Bone Morphogenetic Protein-2 in Localized Alveolar Ridge and Maxillary Sinus Augmentation.

    Science.gov (United States)

    Kelly, Mick P; Vaughn, Olushola L Akinshemoyin; Anderson, Paul A

    2016-05-01

    Recombinant human bone morphogenetic protein-2 (rhBMP-2) is approved by the Food and Drug Administration as a viable alternative to bone graft in spinal fusion and maxillary sinus lift. The research questions for meta-analysis were: Is rhBMP-2 an effective bone graft substitute in localized alveolar ridge augmentation and maxillary sinus floor augmentation? What are the potential adverse events? A search of MEDLINE from January 1980 to January 2014 using PubMed, the Cochrane Database of Systematic Reviews and Controlled Trials, CINAHL, and EMBASE was performed. Searches were performed from Medical Subject Headings. The quality of each study included was graded by Review Manager software. The primary outcome variable was bone formation measured as change in bone height on computed tomogram. A systematic review of adverse events also was performed. A random-effects model was chosen. Continuous variables were calculated using the standardized mean difference and 95% confidence intervals (CIs) comparing improvement from baseline of the experimental group with that of the control group. Change in bone height was calculated using logarithmic odds ratio. Test of significance used the Z statistic with a P value of .05. Ten studies met the criteria for systematic review; 8 studies were included in the meta-analysis. Five studies assessed localized alveolar ridge augmentation and resulted in an overall standardized mean difference of 0.56 (CI, 0.20-0.92) in favor of BMP; this result was statistically important. Three studies assessed maxillary sinus floor augmentation and resulted in an overall standardized mean difference of -0.50 (CI, -0.93 to -0.09), which was meaningfully different in favor of the control group. Adverse events were inconsistently reported, ranging from no complications to widespread adverse events. For localized alveolar ridge augmentation, this meta-analysis showed that rhBMP-2 substantially increases bone height. However, rhBMP-2 does not perform as

  3. Scintillating plate calorimeter optical design

    International Nuclear Information System (INIS)

    McNeil, R.; Fazely, A.; Gunasingha, R.; Imlay, R.; Lim, J.

    1990-01-01

    A major technical challenge facing the builder of a general purpose detector for the SSC is to achieve an optimum design for the calorimeter. Because of its fast response and good energy resolution, scintillating plate sampling calorimeters should be considered as a possible technology option. The work of the Scintillating Plate Calorimeter Collaboration is focused on compensating plate calorimeters. Based on experimental and simulation studies, it is expected that a sampling calorimeter with alternating layers of high-Z absorber (Pb, W, DU, etc.) and plastic scintillator can be made compensating (e/h = 1.00) by suitable choice of the ratio of absorber/scintillator thickness. Two conceptual designs have been pursued by this subsystem collaboration. One is based on lead as the absorber, with read/out of the scintillator plates via wavelength shifter fibers. The other design is based on depleted uranium as the absorber with wavelength shifter (WLS) plate readout. Progress on designs for the optical readout of a compensating scintillator plate calorimeter are presented. These designs include readout of the scintillator plates via wavelength shifter plates or fiber readout. Results from radiation damage studies of the optical components are presented

  4. A Determinate Model of Thrust-Augmenting Ejectors

    Science.gov (United States)

    Whitley, N.; Krothapalli, A.; van Dommelen, L.

    1996-01-01

    A theoretical analysis of the compressible flow through a constant-area jet-engine ejector in which a primary jet mixes with ambient fluid from a uniform free stream is pursued. The problem is reduced to a determinate mathematical one by prescribing the ratios of stagnation properties between the primary and secondary flows. For some selections of properties and parameters more than one solution is possible and the meaning of these solutions is discussed by means of asymptotic expansions. Our results further show that while under stationary conditions the thrust-augmentation ratio assumes a value of 2 in the large area-ratio limit, for a free-stream Mach number greater than 0.6 very little thrust augmentation is left. Due to the assumptions made, the analysis provides idealized values for the thrust-augmentation ratio and the mass flux entrainment factor.

  5. Can FES-augmented active cycling training improve locomotion in post-acute elderly stroke patients?

    Directory of Open Access Journals (Sweden)

    Elisabetta Peri

    2016-06-01

    Full Text Available Recent studies advocated the use of active cycling coupled with functional electrical stimulation to induce neuroplasticity and enhance functional improvements in stroke adult patients. The aim of this work was to evaluate whether the benefits induced by such a treatment are superior to standard physiotherapy. A single-blinded randomized controlled trial has been performed on post-acute elderly stroke patients. Patients underwent FES-augmented cycling training combined with voluntary pedaling or standard physiotherapy. The intervention consisted of fifteen 30-minutes sessions carried out within 3 weeks. Patients were evaluated before and after training, through functional scales, gait analysis and a voluntary pedaling test. Results were compared with an age-matched healthy group. Sixteen patients completed the training. After treatment, a general improvement of all clinical scales was obtained for both groups. Only the mechanical efficiency highlighted a group effect in favor of the experimental group. Although a group effect was not found for any other cycling or gait parameters, the experimental group showed a higher percentage of change with respect to the control group (e.g. the gait velocity was improved of 35.4% and 25.4% respectively, and its variation over time was higher than minimal clinical difference for the experimental group only. This trend suggests that differences in terms of motor recovery between the two groups may be achieved increasing the training dose. In conclusion, this study, although preliminary, showed that FES-augmented active cycling training seems to be effective in improving cycling and walking ability in post-acute elderly stroke patients. A higher sample size is required to confirm results.

  6. Augmented spaces, a look beyond advertising

    Directory of Open Access Journals (Sweden)

    Oana Andreea Căplescu

    2014-03-01

    Full Text Available From billboards to urban screens and now to media facades, the augmentation of our cities has expanded, changing social behaviours and public space consumption. Smart buildings are being developed and, much like the smartphones, these hybrids are not only in sci-fi movies anymore. One of the main promoters of media facades and media architecture has been the advertising industry. But artists and designers showed the potential of different approaches, experimenting with digitally augmented spaces both indoors and outdoors. Going beyond the commercial aspect of being an advertising and branding tool, these hybrids offer a variety of uses. Questions of how and where we use them and how they can improve our life quality are discussed here emphasizing that we developed a media behaviour, adjusting our relation to the physical and information environments. I examine some of the most notable experiments outside of the advertising sphere, offering a base for future development of augmented spaces and opening the discussion over the language of new media architecture.

  7. Posterior column acetabular fracture fixation using a W-shaped angular plate: A biomechanical analysis.

    Directory of Open Access Journals (Sweden)

    Ke Su

    Full Text Available The purpose of this study was to compare the stability and feasibility of four fixation constructs in a posterior column acetabular fracture: one reconstruction plate, one reconstruction plate and lag screw, two reconstruction plates, and a W-shaped acetabular angular plate.Twenty embalmed cadaveric pelvises with a posterior column acetabular fractures were allocated to one of four groups: 1 a reconstruction plate, 2 a reconstruction plate with a posterior column lag screw, 3 double reconstruction plates, and 4 a W-shaped acetabular angular plate. These constructs were mechanically loaded on a testing machine, and construct stiffness values were measured. Strain gauges were utilized to measure the mechanical behavior in the condition of compressive force.Final stiffness was not different between the two reconstruction plates (445.81±98.30 N/mm and the W-shaped acetabular angular plate (447.43±98.45 N/mm, p = 0.524, both of which were superior to a single reconstruction plate (248.90±61.95 N/mm and a combined plate and lag screw (326.41±94.34 N/mm. Following the fixation of the W-shaped acetabular angular plate, the strain distribution was similar to the intact condition around the acetabulum. The parameters of the W-shaped acetabular angular plate that were observed at the superior region of the acetabulum were less than those of a single reconstruction plate (p<0.05, a single reconstruction plate with lag screw (p<0.05, and two reconstruction plates (p<0.05.The novel W-shaped acetabular angular plate fixation technique was able to provide the biomechanically stiffest construct for stabilization of a posterior column acetabular fracture; it also resulted in a partial restoration of joint loading parameters toward the intact state.

  8. Dermal fillers for facial soft tissue augmentation.

    Science.gov (United States)

    Dastoor, Sarosh F; Misch, Carl E; Wang, Hom-Lay

    2007-01-01

    Nowadays, patients are demanding not only enhancement to their dental (micro) esthetics, but also their overall facial (macro) esthetics. Soft tissue augmentation via dermal filling agents may be used to correct facial defects such as wrinkles caused by age, gravity, and trauma; thin lips; asymmetrical facial appearances; buccal fold depressions; and others. This article will review the pathogenesis of facial wrinkles, history, techniques, materials, complications, and clinical controversies regarding dermal fillers for soft tissue augmentation.

  9. Integrating Hypermedia Techniques with Augmented Reality Environments

    OpenAIRE

    Sinclair, Patrick

    2004-01-01

    Augmented Reality systems, which overlay virtual information over the real world, can benefit greatly from the techniques established by the Open Hypermedia research field. Storing information and links separately from a document can be advantageous for augmented reality applications and can enable the adaption of content to suit users’ preferences. This thesis explores how Open Hypermedia systems might be used as the information systems behind AR environments. This provides benefits to augme...

  10. Study of uranium plating measurement

    International Nuclear Information System (INIS)

    Lin Jufang; Wen Zhongwei; Wang Mei; Wang Dalun; Liu Rong; Jiang Li; Lu Xinxin

    2007-06-01

    In neutron physics experiments, the measurement for plate-thickness of uranium can directly affect uncertainties of experiment results. To measure the plate-thickness of transform target (enriched uranium plating and depleted uranium plating), the back to back ionization chamber, small solid angle device and Au-Si surface barrier semi-conductor, were used in the experiment study. Also, the uncertainties in the experiment were analyzed. Because the inhomo-geneous of uranium lay of plate can quantitively affect the result, the homogeneity of uranium lay is checked, the experiment result reflects the homogeneity of uranium lay is good. (authors)

  11. Adoption of Technology and Augmentation of Resources for Teaching-Learning in Higher Education

    OpenAIRE

    P. M. Suresh Kumar

    2017-01-01

    Learner centred education through appropriate methodologies facilitates effective learning as teaching-learning modalities of higher education are considered to be relevant to the learner group. Curriculum delivery and pedagogy should incorporate multitude of learning experiences and innovative learning methodologies through adoption of technology. Plenty of resources external to the curriculum come into use, which offer valuable learning experiences. Augmentation of resources for teaching...

  12. Comparison of Thermal Performances between Low Porosity Perforate Plate and Flat Plate Solar Air Collector

    Science.gov (United States)

    Chan, Hoy-Yen; Vinson, A. A.; Baljit, S. S. S.; Ruslan, M. H.

    2018-04-01

    Flat plate solar air collector is the most common collector design, which is relatively simpler to fabricate and lower cost. In the present study, perforated plate solar collector was developed to improve the system thermal performance. A glazed perforated plate of 6mm holes diameter with square geometry was designed and installed as the absorber of the collector. The influences of solar radiation intensity and mass flow rate on the thermal performance were investigated. The perforated collector was compared with the flat plate solar collector under the same operating conditions. The highest values of thermal efficiency in this study for the perforated plate (PP) and the flat plate (FP) solar collectors were 59% and 36% respectively, at solar radiation intensity of 846 Wm-2 and mass flow rate of 0.02 kgs-1. Furthermore, PP collector gave better thermal performance compared to FP collector; and compared to previous studies, the present perforated design was compatible with the flat plate with double pass designs.

  13. Analysis of clinical efficacy and complications of titanium mini plate internal fixation and reconstructive surgery for patients with orbital fracture

    Directory of Open Access Journals (Sweden)

    Yang Liu

    2016-07-01

    Full Text Available AIM: To analyze the clinical efficacy and complications of titanium mini plate internal fixation and reconstructive surgery for patients with orbital fracture. METHODS: Fifty-seven cases(60 eyeswith orbital fracture from March 2013 to April 2014 in our hospital were researched. According to the random number table method, the patients were divided into observation group(29 cases with 30 eyesand control group(28 cases with 30 eyes. The control group was treated with hydroxyapatite artificial bone plate for internal fixation, and the observation group with titanium mini plate internal fixation and reconstructive surgery. The diplopia grading, grading of ocular movement disorder before and at 1, 3mo after treatment and postoperative complications(prolapse, dislocation, infectionwere compared between the two groups. RESULTS: In both group, all the 60 eyes were healed without scar formation. The rate of diplopia grading as grade 0 1mo postoperatively of observation group and the control groups were 63% and 40%(PPPCONCLUSION: The clinical curative effect of titanium mini plate internal fixation and reconstructive surgery has a good effect for orbital fractures, which can improve the therapeutic effect and reduce the incidence of adverse reactions.

  14. Ozone-augmented percutaneous discectomy: A novel treatment option for refractory discogenic sciatica

    International Nuclear Information System (INIS)

    Crockett, M.T.; Moynagh, M.; Long, N.; Kilcoyne, A.; Dicker, P.; Synnott, K.; Eustace, S.J.

    2014-01-01

    Aim: To assess the short and medium-term efficacy and safety of a novel, minimally invasive therapeutic option combining automated percutaneous lumbar discectomy, intradiscal ozone injection, and caudal epidural: ozone-augmented percutaneous discectomy (OPLD). Materials and methods: One hundred and forty-seven patients with a clinical and radiological diagnosis of discogenic sciatica who were refractory to initial therapy were included. Fifty patients underwent OPLD whilst 97 underwent a further caudal epidural. Outcomes were evaluated using McNab's score, improvement in visual analogue score (VAS) pain score, and requirement for further intervention. Follow-up occurred at 1 and 6 months, and comparison was made between groups. Results: OPLD achieved successful outcomes in almost three-quarters of patients in the short and medium term. OPLD achieved superior outcomes at 1 and 6 months compared to caudal epidural. There was a reduced requirement for further intervention in the OPLD group. No significant complications occurred in either group. Discussion: OPLD is a safe and effective treatment for patients with refractory discogenic sciatica in the short and medium term. OPLD has the potential to offer an alternative second-line minimally invasive treatment option that could reduce the requirement for surgery in this patient cohort. - Highlights: • Discogenic sciatica is a common condition which causes significant morbidity. • Ozone augmented percutaneous lumbar discectomy (OPLD) is a novel treatment. • Comparison was made to caudal epidural injection. • All outcomes were superior in the OPLD treatment group. • OPLD appears is an effective treatment for refractory discogenic sciatica

  15. Earth's Decelerating Tectonic Plates

    Energy Technology Data Exchange (ETDEWEB)

    Forte, A M; Moucha, R; Rowley, D B; Quere, S; Mitrovica, J X; Simmons, N A; Grand, S P

    2008-08-22

    Space geodetic and oceanic magnetic anomaly constraints on tectonic plate motions are employed to determine a new global map of present-day rates of change of plate velocities. This map shows that Earth's largest plate, the Pacific, is presently decelerating along with several other plates in the Pacific and Indo-Atlantic hemispheres. These plate decelerations contribute to an overall, globally averaged slowdown in tectonic plate speeds. The map of plate decelerations provides new and unique constraints on the dynamics of time-dependent convection in Earth's mantle. We employ a recently developed convection model constrained by seismic, geodynamic and mineral physics data to show that time-dependent changes in mantle buoyancy forces can explain the deceleration of the major plates in the Pacific and Indo-Atlantic hemispheres.

  16. Potential Use of Augmented Reality in LIS Education

    Science.gov (United States)

    Wójcik, Magdalena

    2016-01-01

    The subject of this article is the use of augmented reality technology in library and information science education. The aim is to determine the scope and potential uses of augmented reality in the education of information professionals. In order to determine the scope and forms of potential use of AR technology in LIS education a two-step…

  17. Augmented Reality, the Future of Contextual Mobile Learning

    Science.gov (United States)

    Sungkur, Roopesh Kevin; Panchoo, Akshay; Bhoyroo, Nitisha Kirtee

    2016-01-01

    Purpose: This study aims to show the relevance of augmented reality (AR) in mobile learning for the 21st century. With AR, any real-world environment can be augmented by providing users with accurate digital overlays. AR is a promising technology that has the potential to encourage learners to explore learning materials from a totally new…

  18. Precise positioning of an intraoral distractor using augmented reality in patients with hemifacial microsomia.

    Science.gov (United States)

    Qu, Miao; Hou, Yikang; Xu, Yourong; Shen, Congcong; Zhu, Ming; Xie, Le; Wang, Hao; Zhang, Yan; Chai, Gang

    2015-01-01

    Through three-dimensional real time imaging, augmented reality (AR) can provide an overlay of the anatomical structure, or visual cues for specific landmarks. In this study, an AR Toolkit was used for distraction osteogenesis with hemifacial microsomia to define the mandibular osteotomy line and assist with intraoral distractor placement. 20 patients with hemifacial microsomia were studied and were randomly assigned to experimental and control groups. Pre-operative computed tomography was used in both groups, whereas AR was used in the experimental group. Afterwards, pre- and post-operative computed tomographic scans of both groups were superimposed, and several measurements were made and analysed. Both the conventional method and AR technique achieved proper positioning of the osteotomy planes, although the AR was more accurate. The difference in average vertical distance from the coronoid and condyle process to the pre- and post-operative cutting planes was significant (p 0.05) was observed in the average angle between the two planes. The difference in deviations between the intersection points of the overlaid mandible across two cutting planes was also significant (p Augmented reality tools such as the AR Toolkit may be helpful for precise positioning of intraoral distractors in patients with hemifacial microsomia in craniofacial surgery. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  19. Three-axis optical force plate for studies in small animal locomotor mechanics

    International Nuclear Information System (INIS)

    Hsieh, S. Tonia

    2006-01-01

    The use of force plates to measure whole-body locomotor mechanics is a well-established technique. However, commercially available force plates are not sensitive enough for use on small-bodied vertebrates or invertebrates. The standard design for single- and multiple-axis, high-sensitivity force plates built by individual research groups uses semiconductor foil strain gauges to measure deflections; yet foil strain gauges are highly temperature and position sensitive, resulting in a drifting base line and nonlinear responses. I present here a design for a three-axis optical force plate that was successfully calibrated to measure forces as small as 1.5 mN and is capable of determining the position of center of pressure with a mean error of 0.07 cm along the X axis and 0.13 cm along the Y axis. Using optical sensors instead of foil strain gauges to measure deflection, this force plate is not subject to temperature-related drift and is more robust against slight positioning inaccuracies. This force plate was used to measure forces produced by amphibious fishes weighing less than 2 g as they jumped off the force platform

  20. Composite augmentation phalloplasty: personal experience after 275 patients

    Directory of Open Access Journals (Sweden)

    Juan Monreal

    2015-03-01

    Full Text Available Aim: To report the author's experience in augmentation phalloplasty by studying a retrospective series of patients who underwent fat grafting for girth enhancement or a composite technique based on suspensory ligament release plus fat grafting performed simultaneously. Methods: The author analyzed retrospectively the outcomes of 275 augmentation phalloplasty procedures performed in 259 patients until November 2013. Of these, 127 correspond to girth augmentation with fat grafting and 148 to composite augmentation phalloplasty (girth augmentation with fat grafting and length improvement by suspensory ligament release. In 16 patients girth and length enhancement were performed in two separate procedures. Results: Of this 259 patients, 87 underwent postoperative follow-up for at least 12 months and 160 patients underwent follow-up for at least 6 months. The average increase in circumference at 6 months was 1.7 cm (1.57 cm at 12 months and the average increase in length of 3.2 cm (3.1 cm at 12 months. Twenty-two patients showed minor complications that were treated without sequelae and without influencing the final result. Conclusion: By judicious use of currently available techniques, it is possible to achieve stable increases in penis size. The use of composite techniques provides better final results than the use of individual techniques performed alone due to the increase of the actual volume of the penis. An adequate informed consent is essential in all patients due to the unrealistic expectations expressed by the majority of them.

  1. Breaking the Barriers to True Augmented Reality

    OpenAIRE

    Sandor, Christian; Fuchs, Martin; Cassinelli, Alvaro; Li, Hao; Newcombe, Richard; Yamamoto, Goshiro; Feiner, Steven

    2015-01-01

    In recent years, Augmented Reality (AR) and Virtual Reality (VR) have gained considerable commercial traction, with Facebook acquiring Oculus VR for \\$2 billion, Magic Leap attracting more than \\$500 million of funding, and Microsoft announcing their HoloLens head-worn computer. Where is humanity headed: a brave new dystopia-or a paradise come true? In this article, we present discussions, which started at the symposium "Making Augmented Reality Real", held at Nara Institute of Science and Te...

  2. Thrust augmentation for a small turbojet engine

    OpenAIRE

    Hackaday, Gary L.

    1999-01-01

    Approved for public release; distribution is unlimited A Sophia J450 (nine pounds of thrust) gas turbine engine was used first to examine the thrust augmentation generated using an ejector shroud. Experimental results obtained with and without the ejector were compared with performance predicted using an engine code and a one-dimensional ejector analysis. The engine code was revised to incorporate a radial turbine and the correct compressor map. Thrust augmentation of 3-10% was measured an...

  3. The impact of augmented information on visuo-motor adaptation in younger and older adults.

    Directory of Open Access Journals (Sweden)

    Mathias Hegele

    Full Text Available BACKGROUND: Adjustment to a visuo-motor rotation is known to be affected by ageing. According to previous studies, the age-related differences primarily pertain to the use of strategic corrections and the generation of explicit knowledge on which strategic corrections are based, whereas the acquisition of an (implicit internal model of the novel visuo-motor transformation is unaffected. The present study aimed to assess the impact of augmented information on the age-related variation of visuo-motor adjustments. METHODOLOGY/PRINCIPAL FINDINGS: Participants performed aiming movements controlling a cursor on a computer screen. Visual feedback of direction of cursor motion was rotated 75 degrees relative to the direction of hand motion. Participants had to adjust to this rotation in the presence and absence of an additional hand-movement target that explicitly depicted the input-output relations of the visuo-motor transformation. An extensive set of tests was employed in order to disentangle the contributions of different processes to visuo-motor adjustment. Results show that the augmented information failed to affect the age-related variations of explicit knowledge, adaptive shifts, and aftereffects in a substantial way, whereas it clearly affected initial direction errors during practice and proprioceptive realignment. CONCLUSIONS: Contrary to expectations, older participants apparently made no use of the augmented information, whereas younger participants used the additional movement target to reduce initial direction errors early during practice. However, after a first block of trials errors increased, indicating a neglect of the augmented information, and only slowly declined thereafter. A hypothetical dual-task account of these findings is discussed. The use of the augmented information also led to a selective impairment of proprioceptive realignment in the younger group. The mere finding of proprioceptive realignment in adaptation to a visuo

  4. Handling Occlusions for Robust Augmented Reality Systems

    Directory of Open Access Journals (Sweden)

    Maidi Madjid

    2010-01-01

    Full Text Available Abstract In Augmented Reality applications, the human perception is enhanced with computer-generated graphics. These graphics must be exactly registered to real objects in the scene and this requires an effective Augmented Reality system to track the user's viewpoint. In this paper, a robust tracking algorithm based on coded fiducials is presented. Square targets are identified and pose parameters are computed using a hybrid approach based on a direct method combined with the Kalman filter. An important factor for providing a robust Augmented Reality system is the correct handling of targets occlusions by real scene elements. To overcome tracking failure due to occlusions, we extend our method using an optical flow approach to track visible points and maintain virtual graphics overlaying when targets are not identified. Our proposed real-time algorithm is tested with different camera viewpoints under various image conditions and shows to be accurate and robust.

  5. Experimental Fracture Model versus Osteotomy Model in Metacarpal Bone Plate Fixation

    Directory of Open Access Journals (Sweden)

    S. Ochman

    2011-01-01

    Full Text Available Introduction. Osteotomy or fracture models can be used to evaluate mechanical properties of fixation techniques of the hand skeleton in vitro. Although many studies make use of osteotomy models, fracture models simulate the clinical situation more realistically. This study investigates monocortical and bicortical plate fixation on metacarpal bones considering both aforementioned models to decide which method is best suited to test fixation techniques. Methods. Porcine metacarpal bones (=40 were randomized into 4 groups. In groups I and II bones were fractured with a modified 3-point bending test. The intact bones represented a further control group to which the other groups after fixation were compared. In groups III and IV a standard osteotomy was carried out. Bones were fixated with plates monocortically (group I, III and bicortically (group II, IV and tested for failure. Results. Bones fractured at a mean maximum load of 482.8 N ± 104.8 N with a relative standard deviation (RSD of 21.7%, mean stiffness was 122.3 ± 35 N/mm. In the fracture model, there was a significant difference (=0.01 for maximum load of monocortically and bicortically fixed bones in contrast to the osteotomy model (=0.9. Discussion. In the fracture model, because one can use the same bone for both measurements in the intact state and the bone-plate construct states, the impact of inter-individual differences is reduced. In contrast to the osteotomy model there are differences between monocortical and bicortical fixations in the fracture model. Thus simulation of the in vivo situation is better and seems to be suitable for the evaluation of mechanical properties of fixation techniques on metacarpals.

  6. Augmented Reality Imaging System: 3D Viewing of a Breast Cancer.

    Science.gov (United States)

    Douglas, David B; Boone, John M; Petricoin, Emanuel; Liotta, Lance; Wilson, Eugene

    2016-01-01

    To display images of breast cancer from a dedicated breast CT using Depth 3-Dimensional (D3D) augmented reality. A case of breast cancer imaged using contrast-enhanced breast CT (Computed Tomography) was viewed with the augmented reality imaging, which uses a head display unit (HDU) and joystick control interface. The augmented reality system demonstrated 3D viewing of the breast mass with head position tracking, stereoscopic depth perception, focal point convergence and the use of a 3D cursor and joy-stick enabled fly through with visualization of the spiculations extending from the breast cancer. The augmented reality system provided 3D visualization of the breast cancer with depth perception and visualization of the mass's spiculations. The augmented reality system should be further researched to determine the utility in clinical practice.

  7. Effective augmentation of networked systems and enhancing pinning controllability

    Science.gov (United States)

    Jalili, Mahdi

    2018-06-01

    Controlling dynamics of networked systems to a reference state, known as pinning control, has many applications in science and engineering. In this paper, we introduce a method for effective augmentation of networked systems, while also providing high levels of pinning controllability for the final augmented network. The problem is how to connect a sub-network to an already existing network such that the pinning controllability is maximised. We consider the eigenratio of the augmented Laplacian matrix as a pinning controllability metric, and use graph perturbation theory to approximate the influence of edge addition on the eigenratio. The proposed metric can be effectively used to find the inter-network links connecting the disjoint networks. Also, an efficient link rewiring approach is proposed to further optimise the pinning controllability of the augmented network. We provide numerical simulations on synthetic networks and show that the proposed method is more effective than heuristic ones.

  8. Create Your Plate

    Medline Plus

    Full Text Available ... ready, you can try new foods within each food category. Try these seven steps to get started: Using your dinner plate, put a line down the middle of the plate. Then on one side, cut it ... and starchy foods. See this list of grains and starchy foods . ...

  9. A Preliminary Study of D-Cycloserine Augmentation of Cognitive-Behavioral Therapy in Pediatric Obsessive-Compulsive Disorder

    Science.gov (United States)

    Storch, Eric A.; Murphy, Tanya K.; Goodman, Wayne K.; Geffken, Gary R.; Lewin, Adam B.; Henin, Aude; Micco, Jamie A.; Sprich, Susan; Wilhelm, Sabine; Bengtson, Michael; Geller, Daniel A.

    2010-01-01

    Background Research on the neural circuitry underlying fear extinction has led to the examination of d-cycloserine (DCS), a partial agonist at the NMDA receptor in the amygdala, as a method of enhancing exposure therapy outcome. Preliminary results have supported the use of DCS to augment exposure therapy in adult anxiety disorders; however, no data have been reported in any childhood anxiety disorder. Thus, we sought to preliminarily examine if weight-adjusted DCS doses (25 or 50mg) enhanced the overall efficacy of cognitive-behavioral therapy (CBT) for pediatric obsessive-compulsive disorder (OCD). Method Participants were 30 youth (ages 8–17) with a primary diagnosis of OCD. The study design was a randomized, double-blinded, placebo-controlled augmentation trial examining CBT+DCS versus CBT+Placebo (15 youth per group). All patients received 7 E/RP sessions paired with DCS or placebo taken 1 hour prior to sessions. Results Although not significantly different, compared to the CBT+Placebo group, youth in the CBT+DCS arm showed small-to-moderate treatment effects (d=.31 to .47 on primary outcomes). No adverse events were recorded. Conclusions The present results complement findings in adult OCD and non-OCD anxiety disorders and provide initial support for a more extensive study of DCS augmentation of CBT among youth with OCD. PMID:20817153

  10. Observation on the role of osteoporotic vertebra augmented with calcium sulfate cement in vivo

    International Nuclear Information System (INIS)

    Zhu Xuesong; Shi Qin; Zhang Zhiming; Geng Dechun; Mao Haiqing; Chen Chunmao; Wang Genlin; Yang Huilin

    2010-01-01

    Objective: To observe the biomechanical and histological performance of calcium sulfate cement (CSC) in osteoporotic vertebral bodies. Methods: Bone voids were created in L 2 ∼ L 5 vertebras of twelve female osteoporotic mature sheep. CSC and polymethylmethacrylate (PMMA) were injected into one bone voids randomly, L 1 and L 6 vertebrae served as the normal control. Six sheep were sacrificed at the 2nd week and the 24th week after operation respectively. Overall observation,biomechanical test and undecalcified bone histology analyses were performed. Results: Biomechanical analysis showed that the vertebrae could be augmented by CSC and PMMA. The biomechanical properties of the vertebrae augmented with CSC were weakened more than that in the PMMA and normal group at the 2nd week, increased significantly at the 24th week. Histological observation showed that CSC was mostly absorbed at the 24th week, mature bone trabecula was seen in the defect area. Conclusion: The osteoporotic vertebrae can be augmented instantly by CSC. As time goes on, CSC can promote bone remodeling, and enhance the vertebrae. It is an alternation for vertebroplasty and kyphoplasty. (authors)

  11. Augmenting performance feedback does not affect 4 km cycling time-trials in the heat.

    Science.gov (United States)

    Waldron, Mark; Villerius, Vincent; Murphy, Aron

    2015-01-01

    We compared the effects of (1) accurate and (2) surreptitiously augmented performance feedback on power output and physiological responses to a 4000 m time-trial in the heat. Nine cyclists completed a baseline (BaseL) 4000 m time-trial in ambient temperatures of 30°C, followed by two further 4000 m time-trials at the same temperature, randomly assigning the participants to an accurate (ACC; accurate feedback of baseline) or deceived (DEC; 2% increase above baseline) feedback group. The total power output (PO) and aerobic (Paer) and anaerobic (Pan) contributions were determined at 0.4 km stages during the time-trials, alongside measurements of rectal (Trec) and skin (Tskin) temperatures. There were no differences (P > 0.05) in any of the variables between BaseL, ACC and DEC, despite increases (P 0.05) between feedback condition and time-trial stage. Providing surreptitiously augmented performance feedback to well-trained cyclists did not alter their performance or physiological responses to a 4000 m time-trial in a hot environment. The assumed influence of augmented performance feedback was nullified in the heat, perhaps reflecting a central down-regulation of exercise intensity in response to an increased body temperature.

  12. Comparison of the hydrogeology and water quality of a ground-water augmented lake with two non-augmented lakes in northwest Hillsborough County, Florida

    Science.gov (United States)

    Metz, Patricia A.; Sacks, Laura A.

    2002-01-01

    The hydrologic effects associated with augmenting a lake with ground water from the Upper Floridan aquifer were examined in northwest Hillsborough County, Florida, from June 1996 through May 1999. The hydrogeology, ground-water flow patterns, water budgets, and water-quality characteristics were compared between a lake that has been augmented for more than 30 years (Round Lake) and two nearby nonaugmented lakes (Dosson Lake and Halfmoon Lake). Compared to the other study lakes, Round Lake is in a more leakage-dominated hydrogeologic setting. The intermediate confining unit is thin or highly breached, which increases the potential for vertical ground-water flow. Round Lake has the least amount of soft, organic lake-bottom sediments and the lake bottom has been dredged deeper and more extensively than the other study lakes, which could allow more leakage from the lake bottom. The area around Round Lake has experienced more sinkhole activity than the other study lakes. During this study, three sinkholes developed around the perimeter of the lake, which may have further disrupted the intermediate confining unit.Ground-water flow patterns around Round Lake were considerably different than the nonaugmented lakes. For most of the study, groundwater augmentation artificially raised the level of Round Lake to about 2 to 3 feet higher than the adjacent water table. As a result, lake water recharged the surficial aquifer around the entire lake perimeter, except during very wet periods when ground-water inflow occurred around part of the lake perimeter. The non-augmented lakes typically had areas of ground-water inflow and areas of lake leakage around their perimeter, and during wet periods, ground-water inflow occurred around the entire lake perimeter. Therefore, the area potentially contributing ground water to the non-augmented lakes is much larger than for augmented Round Lake. Vertical head loss within the surficial aquifer was greater at Round Lake than the other study

  13. Implementation of augmented reality in operative dentistry learning.

    Science.gov (United States)

    Llena, C; Folguera, S; Forner, L; Rodríguez-Lozano, F J

    2018-02-01

    To evaluate the efficacy of augmented reality (AR) in the gaining of knowledge and skills amongst dental students in the design of cavity preparations and analyse their degree of satisfaction. AR cavity models were prepared for use with computers and mobile devices. Forty-one students were divided into two groups (traditional teaching methods vs AR). Questionnaires were designed to evaluate knowledge and skills, with the administration of a satisfaction questionnaire for those using AR. The degree of compliance with the standards in cavity design was assessed. The Mann-Whitney U-test was used to compare knowledge and skills between the two groups, and the Wilcoxon test was applied to compare intragroup differences. The chi-square test in turn was used to compare the qualitative parameters of the cavity designs between the groups. Statistical significance was considered for P.05). Although the results corresponding to most of the studied skills parameters were better in the experimental group, significant differences (Pmobile devices (10%). The AR techniques favoured the gaining of knowledge and skills and were regarded as a useful tool by the students. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. PEEK versus titanium locking plates for proximal humerus fracture fixation: a comparative biomechanical study in two- and three-part fractures.

    Science.gov (United States)

    Schliemann, Benedikt; Seifert, Robert; Theisen, Christina; Gehweiler, Dominic; Wähnert, Dirk; Schulze, Martin; Raschke, Michael J; Weimann, Andre

    2017-01-01

    The high rigidity of metal implants may be a cause of failure after fixation of proximal humerus fractures. Carbon fiber-reinforced polyetheretherketone (PEEK) plates with a modulus similar to human cortical bone may help to overcome this problem. The present study assesses the biomechanical behavior of a PEEK plate compared with a titanium locking plate. Unstable two- and three-part fractures were simulated in 12 pairs of cadaveric humeri and were fixed with either a PEEK or a titanium locking plate using a pairwise comparison. With an optical motion capture system, the stiffness, failure load, plate bending, and the relative motion at the bone-implant interface and at the fracture site were evaluated. The mean load to failure for two- and three-part fracture fixations was, respectively, 191 N (range 102-356 N) and 142 N (range 102-169 N) in the PEEK plate group compared with 286 N (range 191-395 N) and 258 N (range 155-366 N) in the titanium locking plate group. The PEEK plate showed significantly more bending in both the two- and three-part fractures (p PEEK plate showed lower fixation strength and increased motion at the bone-implant interface compared with a titanium locking plate.

  15. Effect of nanofluids on the performance of a miniature plate heat exchanger with modulated surface

    International Nuclear Information System (INIS)

    Pantzali, M.N.; Kanaris, A.G.; Antoniadis, K.D.; Mouza, A.A.; Paras, S.V.

    2009-01-01

    In the present work, the effect of the use of a nanofluid in a miniature plate heat exchanger (PHE) with modulated surface has been studied both experimentally and numerically. First, the thermophysical properties (i.e., thermal conductivity, heat capacity, viscosity, density and surface tension) of a typical nanofluid (CuO in water, 4% v/v) were systematically measured. The effect of surface modulation on heat transfer augmentation and friction losses was then investigated by simulating the existing miniature PHE as well as a notional similar PHE with flat plate using a CFD code. Finally, the effect of the nanofluid on the PHE performance was studied and compared to that of a conventional cooling fluid (i.e., water). The results suggest that, for a given heat duty, the nanofluid volumetric flow rate required is lower than that of water causing lower pressure drop. As a result, smaller equipment and less pumping power are required. In conclusion, the use of the nanofluids seems to be a promising solution towards designing efficient heat exchanging systems, especially when the total volume of the equipment is the main issue. The only drawbacks so far are the high price and the possible instability of the nanoparticle suspensions.

  16. Aesthetic occiput augmentation using methylmethacrylate.

    Science.gov (United States)

    Song, Yong Tai

    2015-01-01

    Cranioplasty for only aesthetic reasons has not been commonly performed to date. However, recently there has been a new focus by the public on a more aesthetically pleasing head shape with frequent patient requests for purely aesthetic contouring of the occiput, an important definer of cosmetic head shape. For example, in Asia, where the normal cranial shape is mesocephalic or brachycephalic and often with a planar occiput, requests for its aesthetic correction are increasingly common. Accordingly, the author developed a minimally invasive occiput augmentation using methylmethacrylate. In this study, the indications for aesthetic occiput contouring were planar occiput, left-right asymmetric occiput, and grooved occiput. Under local anesthesia, soft methylmethacrylate is subperiosteally inserted through a small incision (about 5-cm length), manually and precisely contoured in situ through the scalp to the desired occipital shape. All is performed as an outpatient procedure, and a quick recovery is the case. Between March 2007 and October 2013, 959 patients received such aesthetic occiput augmentation. The mean follow-up period was 49 months (range, 3-84 months). Nearly all patients were satisfied with the outcome, and complications were very rare. Only 5 patients (0.5%) needed additional corrective procedures. The author has concluded that aesthetic occiput augmentation using methylmethacrylate yields consistent, predictable, and satisfactory results. Additional long-term follow-up is required for a final conclusion, however.

  17. Indonesian Landforms and Plate Tectonics

    Directory of Open Access Journals (Sweden)

    Herman Th. Verstappen

    2014-06-01

    Full Text Available DOI: 10.17014/ijog.v5i3.103The horizontal configuration and vertical dimension of the landforms occurring in the tectonically unstable parts of Indonesia were resulted in the first place from plate tectonics. Most of them date from the Quaternary and endogenous forces are ongoing. Three major plates – the northward moving Indo-Australian Plate, the south-eastward moving SE-Asian Plate and the westward moving Pacific Plate - meet at a plate triple-junction situated in the south of New Guinea’s Bird’s Head. The narrow North-Moluccan plate is interposed between the Asia and Pacific. It tapers out northward in the Philippine Mobile Belt and is gradually disappearing. The greatest relief amplitudes occur near the plate boundaries: deep ocean trenches are associated with subduction zones and mountain ranges with collision belts. The landforms of the more stable areas of the plates date back to a more remote past and, where emerged, have a more subdued relief that is in the first place related to the resistance of the rocks to humid tropical weathering Rising mountain ranges and emerging island arcs are subjected to rapid humid-tropical river erosions and mass movements. The erosion products accumulate in adjacent sedimentary basins where their increasing weight causes subsidence by gravity and isostatic compensations. Living and raised coral reefs, volcanoes, and fault scarps are important geomorphic indicators of active plate tectonics. Compartmental faults may strongly affect island arcs stretching perpendicular to the plate movement. This is the case on Java. Transcurrent faults and related pull-apart basins are a leading factor where plates meet at an angle, such as on Sumatra. The most complicated situation exists near the triple-junction and in the Moluccas. Modern research methods, such as GPS measurements of plate movements and absolute dating of volcanic outbursts and raised coral reefs are important tools. The mega-landforms resulting

  18. Application of a Brittle Damage Model to Normal Plate-on-Plate Impact

    National Research Council Canada - National Science Library

    Raftenberg, Martin N

    2005-01-01

    A brittle damage model presented by Grinfeld and Wright of the U.S. Army Research Laboratory was implemented in the LS-DYNA finite element code and applied to the simulation of normal plate-on-plate impact...

  19. Augmenting Your Own Reality: Student Authoring of Science-Based Augmented Reality Games

    Science.gov (United States)

    Klopfer, Eric; Sheldon, Josh

    2010-01-01

    Augmented Reality (AR) simulations superimpose a virtual overlay of data and interactions onto a real-world context. The simulation engine at the heart of this technology is built to afford elements of game play that support explorations and learning in students' natural context--their own community and surroundings. In one of the more recent…

  20. [Experimental study on carbon fiber reinforced plastic plate--analysis of stabilizing force required for plate].

    Science.gov (United States)

    Iizuka, H

    1990-11-01

    Plates currently in use for the management of bone fracture made of metal present with various problems. We manufactured carbon fiber reinforced plastic (CFRP) plates from Pyrofil T/530 puriplegs overlaid at cross angles of +/- 10 degrees, +/- 20 degrees, and +/- 30 degrees for trial and carried out an experimental study on rabbit tibiofibular bones using 316L stainless steel plates of comparable shape and size as controls. The results indicate the influence of CFRP plate upon cortical bone was milder than that of stainless steel plate, with an adequate stabilizing force for the repair of fractured rabbit tibiofibular bones. CFRP has the advantages over metals of being virtually free from corrosion and fatigue, reasonably radiolucent and able to meet a wide range of mechanical requirements. This would make CFRP plate quite promising as a new devices of treating fracture of bones.

  1. Glass ionomer application for vocal fold augmentation: Histopathological analysis on rabbit vocal fold.

    Science.gov (United States)

    Demirci, Sule; Tuzuner, Arzu; Callıoglu, Elif Ersoy; Yumusak, Nihat; Arslan, Necmi; Baltacı, Bülent

    2016-04-01

    The aim of this study was to investigate the use of glass ionomer cement (GIC) as an injection material for vocal fold augmentation and to evaluate the biocompatibility of the material. Ten adult New Zealand rabbits were used. Under general anesthesia, 0.1-cc GIC was injected to one vocal fold and the augmentation of vocal fold was observed. No injection was applied to the opposite side, which was accepted as the control group. The animals were sacrificed after 3 months and the laryngeal specimens were histopathologically evaluated. The injected and the noninjected control vocal folds were analyzed. The GIC particles were observed in histological sections on the injected side, and no foreign body giant cells, granulomatous inflammation, necrosis, or marked chronic inflammation were detected around the glass ionomer particles. Mild inflammatory reactions were noticed in only two specimens. The noninjected sides of vocal folds were completely normal. The findings of this study suggest that GIC is biocompatible and may be further investigated as an alternative injection material for augmentation of the vocal fold. Further studies are required to examine the viscoelastic properties of GIC and the long-term effects in experimental studies. NA. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  2. Augmented-pressure colostogram in imperforate anus with fistula

    Energy Technology Data Exchange (ETDEWEB)

    Gross, G.W. (Jefferson Medical Coll., Philadelphia, PA (United States). Dept. of Radiology); Wolfson, P.J. (Jefferson Medical Coll., Philadelphia, PA (United States). Dept. of Surgery); Pena, A. (Schneider Children' s Hospital, Long Island Jewish Medical Center, New York, NY (United States). Dept. of Pediatric Surgery)

    1991-12-01

    Most newborns with imperforate anus, except for those with very low varieties, undergo a diverting colostomy performed in the postnatal period, with definitive surgical repair at a later age. Accurate demonstration of the anatomy of any associated fistula between the rectum and urogenital tract is essential for optimal surgical management. An augmented-pressure distal segment colostogram is recommended prior to definitive repair, both to confirm the level of rectal atresia and to define any associated fistulous communication. We report a case of high imperforate anus with rectourethral fistula in which the fistulous tract was not identified on the conventional contrast colostogram but was readily delineated when an augmented-pressure modification of the technique was utilized. The technical aspects of augmented-pressure colostography are presented. (orig.).

  3. Collaboration in Augmented Reality

    NARCIS (Netherlands)

    Lukosch, S.; Billinghurst, M.; Alem, L.; Kiyokawa, K.

    2015-01-01

    Augmented Reality (AR) is a technology that allows users to view and interact in real time with virtual images seamlessly superimposed over the real world. AR systems can be used to create unique collaborative experiences. For example, co-located users can see shared 3D virtual objects that they

  4. Deterministic Local Sensitivity Analysis of Augmented Systems - I: Theory

    International Nuclear Information System (INIS)

    Cacuci, Dan G.; Ionescu-Bujor, Mihaela

    2005-01-01

    This work provides the theoretical foundation for the modular implementation of the Adjoint Sensitivity Analysis Procedure (ASAP) for large-scale simulation systems. The implementation of the ASAP commences with a selected code module and then proceeds by augmenting the size of the adjoint sensitivity system, module by module, until the entire system is completed. Notably, the adjoint sensitivity system for the augmented system can often be solved by using the same numerical methods used for solving the original, nonaugmented adjoint system, particularly when the matrix representation of the adjoint operator for the augmented system can be inverted by partitioning

  5. Adenoma-carcinoma Sequence in the Bladder After Augmentation Cystoplasty

    Directory of Open Access Journals (Sweden)

    Akihiro Naito

    2014-05-01

    Full Text Available We present a case of a 64-year-old woman showing multistep progression from adenoma to adenocarcinoma in the bladder 46 years after augmentation ileocystoplasty. She underwent augmentation ileocystoplasty for tuberculous contracted bladder at 18 years. After 44 years, tubulovillous adenomas were found and resected at the ileovesical anastomosis site. After 2 more years, bladder tumors recurred and revealed adenocarcinomas. Finally, radical cystectomy was required because of frequent recurrence and tumor extensiveness. To our knowledge, this is the first case demonstrating adenoma-carcinoma sequence histopathologically in the bladder after augmentation cystoplasty, indicating multistep carcinogenesis similar to intestinal carcinogenesis.

  6. Labia Majora Augmentation: A Systematic Review of the Literature.

    Science.gov (United States)

    Jabbour, Samer; Kechichian, Elio; Hersant, Barbara; Levan, Philippe; El Hachem, Lena; Noel, Warren; Nasr, Marwan

    2017-10-16

    Currently, there is no standardized approach for labia majora augmentation and controversies still exist regarding this subject. This systematic review aimed to assess the evidence in the literature regarding labia majora augmentation. On November 20, 2016, we conducted an online search of published articles in the Medline, Embase, and Cochrane databases. All articles describing labia majora augmentation were included in this review. Nine studies were selected for inclusion in the systematic review. Only 2 studies were prospective trials. The most commonly used technique was fat grafting with a total of 4 articles and 183 patients. The mean total injected fat volume ranged from 18 mL to 120 mL per session. Two articles described hyaluronic acid injection techniques. The total injected volume of hyaluronic acid ranged from 2 to 6 mL per session. Three articles used surgical techniques for labia majora augmentation. All included articles did not report any major or life-threatening complications. All techniques demonstrated high satisfaction rates. Labia majora augmentation appears to be a safe, efficient technique with a high satisfaction rate and no reported major complications. However, further randomized controlled trials are warranted. 4. © 2017 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com

  7. Evaluation of Using Triangular Plates as Continuity Plates in Box Column Section in Prequalified Welded Connections under Cyclic Loading

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Kafi

    2017-02-01

    Full Text Available Welding of Continuity plates in box columns are not easily possible, therefore some researches has been done for substitution of external continuity plates.In this study first discussed about effects of continuity plate in I beam to Box column with top and bottom plate (WFP and welded unreinforced flange-welded web connection (WUF-W and reduced beam section connection (RBS. Then, triangular plates use to in connection beam to box column as continuity plates and to consider under cyclic loading. Studies have shown that existence of continuity plates in connections mentioned above have averagely increased loading capacity, rigidity and energy absorption 63, 86 and 75 percent respectively. The results also showed that using of triangular plates as continuity plates of box columns causing plastic strain in column flange in the area that concentration of materials is not much in triangular plates and increased the probability of failure in weld of plates to the column flange. Also using of triangular plates as continuity plates have not affected on plastic hinge location.

  8. Augmented reality in intraventricular neuroendoscopy.

    Science.gov (United States)

    Finger, T; Schaumann, A; Schulz, M; Thomale, Ulrich-W

    2017-06-01

    Individual planning of the entry point and the use of navigation has become more relevant in intraventricular neuroendoscopy. Navigated neuroendoscopic solutions are continuously improving. We describe experimentally measured accuracy and our first experience with augmented reality-enhanced navigated neuroendoscopy for intraventricular pathologies. Augmented reality-enhanced navigated endoscopy was tested for accuracy in an experimental setting. Therefore, a 3D-printed head model with a right parietal lesion was scanned with a thin-sliced computer tomography. Segmentation of the tumor lesion was performed using Scopis NovaPlan navigation software. An optical reference matrix is used to register the neuroendoscope's geometry and its field of view. The pre-planned ROI and trajectory are superimposed in the endoscopic image. The accuracy of the superimposed contour fitting on endoscopically visualized lesion was acquired by measuring the deviation of both midpoints to one another. The technique was subsequently used in 29 cases with CSF circulation pathologies. Navigation planning included defining the entry points, regions of interests and trajectories, superimposed as augmented reality on the endoscopic video screen during intervention. Patients were evaluated for postoperative imaging, reoperations, and possible complications. The experimental setup revealed a deviation of the ROI's midpoint from the real target by 1.2 ± 0.4 mm. The clinical study included 18 cyst fenestrations, ten biopsies, seven endoscopic third ventriculostomies, six stent placements, and two shunt implantations, being eventually combined in some patients. In cases of cyst fenestrations postoperatively, the cyst volume was significantly reduced in all patients by mean of 47%. In biopsies, the diagnostic yield was 100%. Reoperations during a follow-up period of 11.4 ± 10.2 months were necessary in two cases. Complications included one postoperative hygroma and one insufficient

  9. Fundamental processes in ion plating

    International Nuclear Information System (INIS)

    Mattox, D.M.

    1980-01-01

    Ion plating is a generic term applied to film deposition processes in which the substrate surface and/or the depositing film is subjected to a flux of high energy particles sufficient to cause changes in the interfacial region of film properties compared to a nonbombarded deposition. Ion plating is being accepted as an alternative coating technique to sputter deposition, vacuum evaporation and electroplating. In order to intelligently choose between the various deposition techniques, the fundamental mechanisms, relating to ion plating, must be understood. This paper reviews the effects of low energy ion bombardment on surfaces, interface formation and film development as they apply to ion plating and the implementation and applications of the ion plating process

  10. Human-Assisted AI: an Intelligence Augmentation Approach

    OpenAIRE

    Alicea, Bradly

    2018-01-01

    As a flavor of Human-Computer Interaction (HCI), Human-Assisted AI can serve to both augment both human performance and artificial systems. This talk will feature a discussion of Human-assisted AI as an instance of Intelligence Augmentation (IA). We will discuss instances of weak and strong IA, in addition to contemporary examples of and paths forward for such systems. In the variety of models presented, data plays a critical role in the structure of interactions between human and artificial ...

  11. Soft tissue augmentation 2006: filler fantasy.

    Science.gov (United States)

    Klein, Arnold William

    2006-01-01

    As an increasing number of patients seek esthetic improvement through minimally invasive procedures, interest in soft tissue augmentation and filling agents is at an all-time high. One reason for this interest is the availability of botulinum toxin type A, which works superbly in the upper face. The rejuvenation of the upper face has created much interest in injectable filling agents and implant techniques that work equally well in the restoration of the lower face. One of the central tenets of soft tissue augmentation is the concept of the three-dimensional face. The youthful face has a soft, full appearance, as opposed to the flat, pulled, two-dimensional look often achieved by more traditional surgical approaches. Injectable filling agents can augment and even at times, replace pulling. Additionally, with the lip as the focal center of the lower face, subtle lip enhancement is here to stay, and is in fact, the number one indication for injectable fillers. Moreover, minimally invasive soft tissue augmentation offers cosmetic enhancement without the cost and recovery time associated with more invasive procedures. As more and more physicians take interest in minimally invasive surgery, courses in cosmetic surgery techniques are becoming increasingly popular at the medical meetings of many specialties. Today, physicians have a much larger armamentarium of techniques and materials with which to improve facial contours, ameliorate wrinkles, and provide esthetic rejuvenation to the face. For a substance or device to be amenable for soft tissue augmentation in the medical community, it must meet certain criteria. It must have both a high "use" potential, producing cosmetically pleasing results with a minimum undesirable reactions, and have a low abuse potential in that widespread or incorrect or indiscriminate use would not result in significant morbidity. It must be nonteratogenic, noncarcinogenic, and nonmigratory. In addition, the agent must provide predictable

  12. Medical augmentation of labor and the risk of ADHD in offspring

    DEFF Research Database (Denmark)

    Henriksen, Lonny; Wu, Chunsen; Secher, Niels Jørgen

    2015-01-01

    BACKGROUND AND OBJECTIVE: Oxytocin for labor augmentation is widely used in obstetric care in Western countries. Two recent, smaller studies found opposing results regarding the association between prenatal exposure to oxytocin for labor augmentation and attention-deficit/hyperactivity disorder...... (ADHD). In Denmark, oxytocin is the medication used for nearly all medical augmentations of labor, and we examined the association between medical augmentation of labor and ADHD in a large cohort study based on national register data. METHODS: All singletons born after spontaneous onset of labor...... in Denmark between 2000 and 2008 (N = 546 146) were included in the study. Data from the Danish Medical Birth Registry on medical augmentation of labor (yes/no) were used to identify exposed children. ADHD was defined based on the diagnostic codes of International Classification of Diseases, 10th Revision...

  13. Impact of timing on soft tissue augmentation during implant treatment: A systematic review and meta-analysis.

    Science.gov (United States)

    Lin, Cho-Ying; Chen, Zhaozhao; Pan, Whei-Lin; Wang, Hom-Lay

    2018-05-01

    To achieve a predictable esthetic and functional outcome, soft tissue augmentation has become popular in implant treatment. The aim of this systematic review and meta-analysis was to assess the influence of different timing for soft tissue augmentation during implant treatment on soft tissue conditions and its stability. Electronic and manual searches for articles written in English up to September 2017 were performed by two independent reviewers. Human clinical studies with the purpose of evaluating outcomes (at least 3-month follow-up) of autogenous soft tissue graft for augmentation during implant treatment, either simultaneous or after implant placement (staged), were included. Cumulative changes of keratinized tissue width (KTW), soft tissue thickness (STT), and mid-buccal mucosal recession (MR) data were analyzed with a random-effects model to compare the postoperative outcomes. Twenty-nine human studies (eight randomized clinical trials, six cohort studies, and 15 case series) that met the inclusion criteria were included. For the overall data, the weighted mean STT gain (1 year after surgery) was 1.03 mm (95% CI: 0.78-1.29 mm), among which the simultaneous group was 1.12 mm (95% CI: 0.75-1.49 mm) and staged group (3-6 months after implant placement) was 0.95 mm (95% CI: 0.58-1.31 mm). There was no statistically significant difference in KTW and MR between 3 months and more than 3 months after surgery. This review revealed that the stability of soft tissue, in terms of KTW and mid-buccal MR, can be obtained 3 months after surgery. There is no difference between simultaneous and staged soft tissue augmentation during implant treatment, and both procedures significantly enhance KTW and STT. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Heating produced by therapeutic ultrasound in the presence of a metal plate in the femur of canine cadavers

    Directory of Open Access Journals (Sweden)

    A.O. Andrades

    2014-10-01

    Full Text Available The present study aimed to assess the heat generated by a therapeutic ultrasound (TUS in a metal bone plate and adjacent structures after fixation to the femur of canine cadavers. Ten pairs of hind limbs were used, and they were equally distributed between groups that were subjected to 1- and 3-MHz frequencies, with each frequency testing 1- and 2-W/cm² intensities. The right hind limb was defined as the control group (absence of the metal plate, and the left hind limb was the test group (presence of the metal plate. Therefore, the control groups (CG were denominated CGI, using TUS with 1-MHz frequency and 1-W/cm² intensity; CGII, using 1-MHz frequency and 2-W/cm² intensity; CGIII, using 3-MHz frequency and 1-W/cm² intensity; and CGIV, using 3-MHz frequency and 2-W/cm² intensity. For each control group, its respective test group (TG was denominated TGI, TGII, TGIII and TGIV. The TUS was applied to the lateral aspect of the thigh using the continuous mode and a 3.5-cm² transducer in a 6.25-cm² area for 2 minutes. Sensors were coupled to digital thermometers that measured the temperature in different sites before (t0 and after (t1 of the TUS application. The temperatures in t1 were higher in all tested groups. The intramuscular temperature was significantly higher (P<0.05 in the groups used to test the 3-MHz frequency in the presence of the metal plate. The therapeutic ultrasound in the continuous mode using frequencies of 1 and 3 MHz and intensities of 1 and 2 W/cm2 for 2 minutes caused heating of the metal plate and adjacent structures after fixation to the femur of canine cadavers.

  15. Augmented Reality og kulturarv

    DEFF Research Database (Denmark)

    Nielsen, Mikkel Kirkedahl Lysholm

    2013-01-01

    Museerne står overfor at skulle omfavne den digitale kultur i håndteringen af den store mængde viden, institutionerne repræsenterer. Augmented Reality-systemer forbinder ved hjælp af moderne teknologi det virtuelle med det virkelige, og kan derfor synes som en oplagt anvendelsesmulighed i...

  16. Modeling RERTR experimental fuel plates using the PLATE code

    International Nuclear Information System (INIS)

    Hayes, S.L.; Meyer, M.K.; Hofman, G.L.; Snelgrove, J.L.; Brazener, R.A.

    2003-01-01

    Modeling results using the PLATE dispersion fuel performance code are presented for the U-Mo/Al experimental fuel plates from the RERTR-1, -2, -3 and -5 irradiation tests. Agreement of the calculations with experimental data obtained in post-irradiation examinations of these fuels, where available, is shown to be good. Use of the code to perform a series of parametric evaluations highlights the sensitivity of U-Mo dispersion fuel performance to fabrication variables, especially fuel particle shape and size distributions. (author)

  17. METHOD OF MAKING AND PLATE CONNECTION

    Science.gov (United States)

    Patriarca, P.; Shubert, C.E.; Slaughter, G.M.

    1963-02-26

    This invention relates to a method of joining, by welding or brazing, a tube to a plate, particularly where the tube and the plate are of different thickness or have different thermal conductivities and are subject to high temperatures. In this method the tube is inserted in the core of a plate containing an annular groove in its back face concentric with the bore and in communication with the bore. One end of the tube is welded substantially flush with the front end of the plate. Brazing alloy is placed in the groove on the back face of the plate and heat is applied to the plate and tube to melt the brazing alloy to permit the alloy to flow into the bore and bond the tube to the plate. (AEC)

  18. D-cycloserine augmentation in behavioral therapy for obsessive-compulsive disorder: a meta-analysis

    Directory of Open Access Journals (Sweden)

    Xia J

    2015-04-01

    Full Text Available Jing Xia,1 Yanqiu Du,2 Jiyang Han,1 Guo Liu,1 Xumei Wang11Department of Psychiatry, Shengjing Hospital of China Medical University, Heping District Shenyang, Liaoning, People’s Republic of China; 2Department of Medicine, Shenyang Ninth People’s Hospital, Tiexi District, Shenyang, Liaoning, People’s Republic of ChinaObjective: To evaluate the overall effect of D-cycloserine (DCS augmentation on exposure and response prevention (ERP therapy for obsessive-compulsive disorder (OCD.Methods: Clinical studies on the effect of DCS augmentation on ERP therapy for OCD compared to placebo were included for meta analysis. The primary outcome was the Yale-Brown Obsessive-Compulsive Scale (Y-BOCS. Meta-analyses were performed with a random-effect model or a fixed-effect model using the Cochrane Review Manager (RevMan, version 5.2 to calculate the odds ratio and the mean difference, with their corresponding 95% confidence intervals.Results: A total of six studies was included in the current meta-analyses, and their data were extracted. Among them, four were for analyses of DCS and Y-BOCS at midtreatment, six for analysis at posttreatment, and four at 3-month follow-up. Besides, three of the six eligible studies were included in the meta-analysis of the DCS and Clinical Global Impression – Severity Scale at posttreatment, and three in the meta-analysis of DCS and proportions of treatment responders and of subjects attaining clinical remission status criteria at posttreatment. Our meta-analyses do not reveal a significant effect of DCS augmentation in ERP therapy for OCD patients, except when measured at midtreatment. Compared to the placebo group, DCS augmentation did show a trend toward significantly lower/decreased Y-BOCS; when measured at posttreatment and in the subpopulation of DCS taken before some of the ERP sessions, DCS augmentation showed a trend toward significantly lower/decreased Y-BOCS.Conclusion: Our result suggested that with the careful

  19. Heating Augmentation for Short Hypersonic Protuberances

    Science.gov (United States)

    Mazaheri, Ali R.; Wood, William A.

    2008-01-01

    Computational aeroheating analyses of the Space Shuttle Orbiter plug repair models are validated against data collected in the Calspan University of Buffalo Research Center (CUBRC) 48 inch shock tunnel. The comparison shows that the average difference between computed heat transfer results and the data is about 9.5%. Using CFD and Wind Tunnel (WT) data, an empirical correlation for estimating heating augmentation on short hypersonic protuberances (k/delta less than 0.3) is proposed. This proposed correlation is compared with several computed flight simulation cases and good agreement is achieved. Accordingly, this correlation is proposed for further investigation on other short hypersonic protuberances for estimating heating augmentation.

  20. Well-plate freeze-drying

    DEFF Research Database (Denmark)

    Trnka, Hjalte; Rantanen, Jukka; Grohganz, Holger

    2015-01-01

    Abstract Context: Freeze-drying in presence of excipients is a common practice to stabilize biomacromolecular formulations. The composition of this formulation is known to affect the quality of the final product. Objective: The aim of this study was to evaluate freeze-drying in well-plates as a h......Abstract Context: Freeze-drying in presence of excipients is a common practice to stabilize biomacromolecular formulations. The composition of this formulation is known to affect the quality of the final product. Objective: The aim of this study was to evaluate freeze-drying in well......-plates as a high throughput platform for formulation screening of freeze-dried products. Methods: Model formulations consisting of mannitol, sucrose and bovine serum albumin were freeze-dried in brass well plates, plastic well plates and vials. Physical properties investigated were solid form, residual moisture......, cake collapse and reconstitution time. Results: Samples freeze-dried in well-plates had an acceptable visual cake appearance. Solid form analysis by high throughput X-ray powder diffraction indicated comparable polymorphic outcome independent of the container. The expected increase in moisture level...

  1. [Web-based analysis of Stilling's color plates].

    Science.gov (United States)

    Kuchenbecker, J

    2014-12-01

    Color vision tests with pseudoisochromatic plates currently represent the most common procedure for the screening of congenital color vision deficiencies. By means of a web-based color vision test, new and old color plates can be tested for diagnostic quality without major effort. A total of 16 digitized Stilling's color plates of the 11th edition from 1907 were included in a web-based color vision test (http://www.farbsehtest.de). The χ(2)-test was used to check whether the Stilling color plates showed similar results to the nine previously evaluated Ishihara color plates. A total of 518 subjects including101 (19.5 %) female subjects with a mean age of 34.6 ± 17 years, took the web-based test with the 25 plates. For all participants the range for the correctly recognized plates was between 5.2 % (n = 27) and 97.7 % (n = 506) for the Stilling color plates and between 64.9 % (n = 336) and 100 % (n = 518) for the Ishihara color plates. For participants with more than 5 errors (n = 247), the range for correctly recognized plates was between 2.0 % (n = 5) and 98.0 % (n = 242) for the Stilling plates and between 42.5 % (n = 105) and 100 % (n = 247) for the Ishihara plates. Taking all color plates and all participants into account there was a significantly higher incidence of erroneous recognition of the Stilling color plates (3038 false and 5250 true answers) compared to the Ishihara color plates (1511 false and 3151 true answers) (p plates could be used for the test edition of the Velhagen/Broschmann/Kuchenbecker color plates from 2014. Overall, the Stilling color plates were recognized with a higher incidence of error by all participants in the web-based test compared to the utilized Ishihara color plates, which in most cases was attributable to ambiguity of some symbols.

  2. Augmented Reality Video Games: New Possibilities and Implications for Children and Adolescents

    Directory of Open Access Journals (Sweden)

    Prithwijit Das

    2017-04-01

    Full Text Available In recent years, the video game market has embraced augmented reality video games, a class of video games that is set to grow as gaming technologies develop. Given the widespread use of video games among children and adolescents, the health implications of augmented reality technology must be closely examined. Augmented reality technology shows a potential for the promotion of healthy behaviors and social interaction among children. However, the full immersion and physical movement required in augmented reality video games may also put users at risk for physical and mental harm. Our review article and commentary emphasizes both the benefits and dangers of augmented reality video games for children and adolescents.

  3. Error-enhanced augmented proprioceptive feedback in stroke rehabilitation training : a pilot study

    NARCIS (Netherlands)

    Molier, Birgit I.; de Boer, Jacintha; Prange, Gerdienke B.; Jannink, Michiel J.A.

    2009-01-01

    Augmented feedback plays an essential role in stroke rehabilitation therapy. When a force is applied to the arm, an augmented sensory (proprioceptive) cue is provided. The question was to find out if stroke patients can learn reach-and retrieval movements with error-enhanced augmented sensory

  4. The Golosyiv plate archive digitisation

    Science.gov (United States)

    Sergeeva, T. P.; Sergeev, A. V.; Pakuliak, L. K.; Yatsenko, A. I.

    2007-08-01

    The plate archive of the Main Astronomical Observatory of the National Academy of Sciences of Ukraine (Golosyiv, Kyiv) includes about 85 000 plates which have been taken in various observational projects during 1950-2005. Among them are about 25 000 of direct northern sky area plates and more than 600 000 plates containing stellar, planetary and active solar formations spectra. Direct plates have a limiting magnitude of 14.0-16.0 mag. Since 2002 we have been organising the storage, safeguarding, cataloguing and digitization of the plate archive. The very initial task was to create the automated system for detection of astronomical objects and phenomena, search of optical counterparts in the directions of gamma-ray bursts, research of long period, flare and other variable stars, search and rediscovery of asteroids, comets and other Solar System bodies to improve the elements of their orbits, informational support of CCD observations and space projects, etc. To provide higher efficiency of this work we have prepared computer readable catalogues and database for 250 000 direct wide field plates. Now the catalogues have been adapted to Wide Field Plate Database (WFPDB) format and integrated into this world database. The next step will be adaptation of our catalogues, database and images to standards of the IVOA. Some magnitude and positional accuracy estimations for Golosyiv archive plates have been done. The photometric characteristics of the images of NGC 6913 cluster stars on two plates of the Golosyiv's double wide angle astrograph have been determined. Very good conformity of the photometric characteristics obtained with external accuracies of 0.13 and 0.15 mag. has been found. The investigation of positional accuracy have been made with A3± format fixed bed scanner (Microtek ScanMaker 9800XL TMA). It shows that the scanner has non-detectable systematic errors on the X-axis, and errors of ± 15 μm on the Y-axis. The final positional errors are about ± 2 μm (

  5. Caffeine Augments Anesthesia Neurotoxicity in the Fetal Macaque Brain.

    Science.gov (United States)

    Noguchi, Kevin K; Johnson, Stephen A; Manzella, Francesca M; Masuoka, Kobe L; Williams, Sasha L; Martin, Lauren D; Dissen, Gregory A; Ikonomidou, Chrysanthy; Schenning, Katie J; Olney, John W; Brambrink, Ansgar M

    2018-03-28

    Caffeine is the most frequently used medication in premature infants. It is the respiratory stimulant of choice for apnea associated with prematurity and has been called the silver bullet in neonatology because of many proven benefits and few known risks. Research has revealed that sedative/anesthetic drugs trigger apoptotic death of neurons and oligodendrocytes in developing mammalian brains. Here we evaluated the influence of caffeine on the neurotoxicity of anesthesia in developing nonhuman primate brains. Fetal macaques (n = 7-8/group), at a neurodevelopmental age comparable to premature human infants, were exposed in utero for 5 hours to no drug (control), isoflurane, or isoflurane + caffeine and examined for evidence of apoptosis. Isoflurane exposure increased apoptosis 3.3 fold for neurons and 3.4 fold for oligodendrocytes compared to control brains. Isoflurane + caffeine caused neuronal apoptosis to increase 8.0 fold compared to control levels but did not augment oligoapoptosis. Neuronal death was particularly pronounced in the basal ganglia and cerebellum. Higher blood levels of caffeine within the range considered therapeutic and safe for human infants correlated with increased neuroapoptosis. Caffeine markedly augments neurotoxicity of isoflurane in the fetal macaque brain and challenges the assumption that caffeine is safe for premature infants.

  6. Augmented Reality for Maintenance and Repair (ARMAR)

    Science.gov (United States)

    2007-08-01

    implementations by leveraging more robust vision algorithms or by using fiducials. 57 Fi gu re 2 3. A ug m en te d co nt ro ls st at e di ag ra m 58...34 Proceedings of the IEEE Conference on Virtual Reality (VR 󈧇), Washington, DC, 2003, p. 199. [18] W. Friedrich , "ARVIKA-Augmented Reality for...and ACM International Symposium on Mixed and Augmented Reality (ISMAR 󈧊), Santa Barbara , CA, 2006, pp. 105-108. [33] S. G. Rao, S. J. Schmugge

  7. Crimes Scenes as Augmented Reality, off-screen, online and offline

    DEFF Research Database (Denmark)

    Sandvik, Kjetil; Waade, Anne-Marit

    Our field of investigation is site specific realism in crime fiction and spatial production as media specific features. We analyze the (re)production of crime scenes in respectively crime series, computer games and tourist practice, and relate this to the ideas of augmented reality. Using...... a distinction between places as locations situated in the physical world and spaces as imagined or virtual locations as our point of departure, this paper investigates how places in various ways have become augmented by means of mediatization. Augmented reality represents processes of mediatization that broaden...... and enhance spatial experiences. These processes are characterized by the activation of users and the creation of artificial operational environments embedded in various physical or virtual locations. The idea of augmented spatial practice is related to the ideas of site specific aesthetic...

  8. Crimes Scenes as Augmented Reality, off-screen, online and offline

    DEFF Research Database (Denmark)

    Sandvik, Kjetil; Waade, Anne Marit

    2008-01-01

    Our field of investigation is site specific realism in crime fiction and spatial production as media specific features. We analyze the (re)production of crime scenes in respectively crime series, computer games and tourist practice, and relate this to the ideas of augmented reality. Using...... a distinction between places as locations situated in the physical world and spaces as imagined or virtual locations as our point of departure, this paper investigates how places in various ways have become augmented by means of mediatization. Augmented reality represents processes of mediatization that broaden...... and enhance spatial experiences. These processes are characterized by the activation of users and the creation of artificial operational environments embedded in various physical or virtual locations. The idea of augmented spatial practice is related to the ideas of site specific aesthetic...

  9. Augmented reality as a design tool for mobile interfaces

    DEFF Research Database (Denmark)

    Bertelsen, Olav Wedege; Nielsen, Christina

    2000-01-01

    applications derived from the classification of augmented reality interfaces. The focus on physical interaction with objects of work and with the mobile device provides us with a range of interaction styles, based on e.g. gestures and manipulation of objects. Furthermore, issues of transparency and directness......This paper challenges user interface paradigms for mobile devices, by using the technical classification of augmented reality interfaces as a thinking tool to develop ideas for interaction with mobile devices. The paper presents future work scenarios from a wastewater treatment plant embodying PDA...... are addressed. The future scenarios indicate that the concepts of augmented reality support solving context problems in mobile design....

  10. Global navigation satellite systems performance analysis and augmentation strategies in aviation

    Science.gov (United States)

    Sabatini, Roberto; Moore, Terry; Ramasamy, Subramanian

    2017-11-01

    In an era of significant air traffic expansion characterized by a rising congestion of the radiofrequency spectrum and a widespread introduction of Unmanned Aircraft Systems (UAS), Global Navigation Satellite Systems (GNSS) are being exposed to a variety of threats including signal interferences, adverse propagation effects and challenging platform-satellite relative dynamics. Thus, there is a need to characterize GNSS signal degradations and assess the effects of interfering sources on the performance of avionics GNSS receivers and augmentation systems used for an increasing number of mission-essential and safety-critical aviation tasks (e.g., experimental flight testing, flight inspection/certification of ground-based radio navigation aids, wide area navigation and precision approach). GNSS signal deteriorations typically occur due to antenna obscuration caused by natural and man-made obstructions present in the environment (e.g., elevated terrain and tall buildings when flying at low altitude) or by the aircraft itself during manoeuvring (e.g., aircraft wings and empennage masking the on-board GNSS antenna), ionospheric scintillation, Doppler shift, multipath, jamming and spurious satellite transmissions. Anyone of these phenomena can result in partial to total loss of tracking and possible tracking errors, depending on the severity of the effect and the receiver characteristics. After designing GNSS performance threats, the various augmentation strategies adopted in the Communication, Navigation, Surveillance/Air Traffic Management and Avionics (CNS + A) context are addressed in detail. GNSS augmentation can take many forms but all strategies share the same fundamental principle of providing supplementary information whose objective is improving the performance and/or trustworthiness of the system. Hence it is of paramount importance to consider the synergies offered by different augmentation strategies including Space Based Augmentation System (SBAS), Ground

  11. Educating Urban Designers using Augmented Reality and Mobile Learning Technologies

    Directory of Open Access Journals (Sweden)

    Ernest Redondo

    2017-03-01

    Full Text Available This paper describes an educational experience using augmented reality (AR on mobile devices as a  tool for learning urban design concepts and specifically for architecture degree students. In a real project-based exercise, the participants had to design a sculpture to be placed in a public space, checking the suitability of the object as for example the form, scale, location, materials, etc., and taking into account the surroundings. The project is controlled on-site using AR on mobile platforms, encouraging collaborative learning by sharing the 3D models of their proposals, and acting both as producers and consumers of AR content in the process. To assess both the usability of technology, as well as the learning improvement, the class was divided into two groups with equivalent pre-course grades: a control group, who followed the conventional course in the laboratory, and a test group, who used AR technology. At the end of the course, the AR-using group showed a significant increase in academic performance, higher motivation and satisfaction compared to the control group.

  12. Molecular phylogenetic trees - On the validity of the Goodman-Moore augmentation algorithm

    Science.gov (United States)

    Holmquist, R.

    1979-01-01

    A response is made to the reply of Nei and Tateno (1979) to the letter of Holmquist (1978) supporting the validity of the augmentation algorithm of Moore (1977) in reconstructions of nucleotide substitutions by means of the maximum parsimony principle. It is argued that the overestimation of the augmented numbers of nucleotide substitutions (augmented distances) found by Tateno and Nei (1978) is due to an unrepresentative data sample and that it is only necessary that evolution be stochastically uniform in different regions of the phylogenetic network for the augmentation method to be useful. The importance of the average value of the true distance over all links is explained, and the relative variances of the true and augmented distances are calculated to be almost identical. The effects of topological changes in the phylogenetic tree on the augmented distance and the question of the correctness of ancestral sequences inferred by the method of parsimony are also clarified.

  13. Research on Design of MUH Attitude Stability Augmentation Control System

    Science.gov (United States)

    Fan, Shigang

    2017-09-01

    Attitude stability augmentation control system with a lower cost need to be designed so that MUH (Mini Unmanned Helicopter) can adapt to different types of geographic environment and fly steadily although the weather may be bad. Attitude feedback was calculated mainly by filtering estimation within attitude acquisition module in this system. Stability augmentation can be improved mainly by PI. This paper will depict running principle and designing process of MUH attitude stability augmentation control system and algorithm that is considered as an important part in this system.

  14. Effectiveness of Aerobic Exercise as an Augmentation Therapy for Inpatients with Major Depressive Disorder: A Preliminary Randomized Controlled Trial.

    Science.gov (United States)

    Shachar-Malach, Tal; Cooper Kazaz, Rena; Constantini, Naama; Lifschytz, Tzuri; Lerer, Bernard

    2015-01-01

    Physical exercise has been shown to reduce depressive symptoms when used in combination with antidepressant medication. We report a randomized controlled trial of aerobic exercise compared to stretching as an augmentation strategy for hospitalized patients with major depression. Male or female patients, 18-80 years, diagnosed with a Major Depressive Episode, were randomly assigned to three weeks of augmentation therapy with aerobic (n=6) or stretching exercise (n=6). Depression was rated, at several time points using the 21-item Hamilton Depression Scale (HAM-D), Beck Depression Inventory (BDI) and other scales. According to the HAM-D, there were four (out of six) responders in the aerobic group, two of whom achieved remission, and none in the stretching group. According to the BDI, there were two responders in the aerobic group who were also remitters and none in the stretching group. The results of this small study suggest that aerobic exercise significantly improves treatment outcome when added to antidepressant medication. However, due to the small sample size the results must be regarded as preliminary and further studies are needed to confirm the findings.

  15. Il telerilevamento a supporto dell’Augmented Reality

    Directory of Open Access Journals (Sweden)

    Filippo Gemma

    2011-04-01

    Full Text Available Fondere insieme realtà e oggetti virtuali per muoversi al meglio con efficacia ed efficienza è quanto si propone, tramite la  Realtà Aumentata, la AGI, Analytical Graphics Inc. di Exton (USA, distribuita in esclusiva in Italia da GMSPAZIO che offre il sistema STK, storicamente conosciuto come Satellite ToolKit che offre più di quarantamila utenti nel mondo un esteso set di funzionalità capaci di soddisfare ogni tipo di esigenza.Remote  Sensing  and  Augmented RealityAugmented reality has been used for years  in  the  broadcast  industry.  You see it every time the National Football League paints a yellow first-down line on the playing field. While it is com-monplace and easy to execute in con-trolled environments with fixed cam-era  positions,  predetermined  angles and known terrain, the opposite is true in uncontrolled environments, such as battlefields in Kandahar. Nonetheless, augmented reality is essential for the warfighter, and the global intelligence community (IC is faced with the chal-lenge  of  efficiently  creating  and  dis-seminating intelligence products from increasing  amounts  of  video  data. AGI’s  Insight3D  development  library is helping to overcome many hurdles of ISR-focused augmented reality.

  16. Il telerilevamento a supporto dell’Augmented Reality

    Directory of Open Access Journals (Sweden)

    Filippo Gemma

    2011-04-01

    Full Text Available Fondere insieme realtà e oggetti virtuali per muoversi al meglio con efficacia ed efficienza è quanto si propone, tramite la  Realtà Aumentata, la AGI, Analytical Graphics Inc. di Exton (USA, distribuita in esclusiva in Italia da GMSPAZIO che offre il sistema STK, storicamente conosciuto come Satellite ToolKit che offre più di quarantamila utenti nel mondo un esteso set di funzionalità capaci di soddisfare ogni tipo di esigenza. Remote  Sensing  and  Augmented Reality Augmented reality has been used for years  in  the  broadcast  industry.  You see it every time the National Football League paints a yellow first-down line on the playing field. While it is com-monplace and easy to execute in con-trolled environments with fixed cam-era  positions,  predetermined  angles and known terrain, the opposite is true in uncontrolled environments, such as battlefields in Kandahar. Nonetheless, augmented reality is essential for the warfighter, and the global intelligence community (IC is faced with the chal-lenge  of  efficiently  creating  and  dis-seminating intelligence products from increasing  amounts  of  video  data. AGI’s  Insight3D  development  library is helping to overcome many hurdles of ISR-focused augmented reality.

  17. Evaluation of plate type fuel options for small power reactors

    International Nuclear Information System (INIS)

    Andrzejewski, Claudio de Sa

    2005-01-01

    Plate type fuels are generally used in research reactor. The utilization of this kind of configuration improves significantly the overall performance fuel. The conception of new fuels for small power reactors based in plate-type configuration needs a complete review of the safety criteria originally used to conduce power and research reactor projects. In this work, a group of safety criteria is established for the utilization of plate-type fuels in small power reactors taking into consideration the characteristics of power and research reactors. The performance characteristics of fuel elements are strongly supported by its materials properties and the adopted configuration for its fissile particles. The present work makes an orientated bibliographic investigation searching the best material properties (structural materials and fuel compounds) related to the performance fuel. Looking for good parafermionic characteristics and manufacturing exequibility associated to existing facilities in national research centres, this work proposes several alternatives of plate type fuels, considering its utilization in small power reactors: dispersions of UO 2 in stainless steel, of UO 2 in zircaloy, and of U-Mo alloy in zircaloy, and monolithic plates of U-Mo cladded with zircaloy. Given the strong dependency of radiation damage with temperature increase, the safety criteria related to heat transfer were verified for all the alternatives, namely the DNBR; coolant temperature lower than saturation temperature; peak meat temperature to avoid swelling; peak fuel temperature to avoid meat-matrix reaction. It was found that all alternatives meet the safety criteria including the 0.5 mm monolithic U-Mo plate cladded with zircaloy. (author)

  18. Facial sculpting and tissue augmentation.

    Science.gov (United States)

    Carruthers, Jean D A; Carruthers, Alastair

    2005-11-01

    Until recently, deep facial sculpting was exclusively the domain of surgical interventions. Recent advances in the available array of dermal and subdermal fillers combined with an esthetic appreciation by both surgeons and nonsurgeons alike of the positive effect of filling the volume-depleted face have led to an expansion in the indications for the use of soft tissue augmenting agents. Subdermal support of the lateral two-thirds of the brow, the nasojugal fold, the malar and buccal fat pads, the lateral lip commissures, and the perioral region, including the pre-jowl sulcus, all restore youthful facial contour and harmony. An important advance in technique is the subdermal rather than the intradermal injection plane. "Instant" facial sculpting giving a brow-lift, cheek-lift, lip expansion, and perioral augmentation is possible using modern soft tissue augmenting agents. The softer, more relaxed appearance contrasts to the somewhat "pulled" appearance of subjects who have had surgical overcorrections. Treatments can be combined with botulinum toxin and other procedures if required. Newer advances in the use of fillers include the use of fillers injected in the subdermal plane for "lunchtime" facial sculpting. Using the modern esthetic filler compounds, which are biodegradable but longer lasting, subjects can have a "rehearsal" treatment or make it ongoing. Some individuals, such as those with human immunodeficiency virus (HIV)-related lipoatrophy or those who desire to obtain a longer-lasting effect, may elect to use a nonbiodegradable filling agent.

  19. New Augmented Reality Taxonomy: Technologies and Features of Augmented Environment.

    OpenAIRE

    Hugues , Olivier; Fuchs , Philippe; Nannipieri , Olivier

    2011-01-01

    978-1-4614-0063-9; This article has a dual aim: firstly to define augmented reality (AR) en- vironments and secondly, based on our definition, a new taxonomy enabling these environments to be classified. After briefly reviewing existing classifica- tions, we define AR by its purpose, ie. to enable someone to create sensory- motor and cognitive activities in a new space combining the real environment and a virtual environment. Below we present our functional taxonomy of AR environments. We div...

  20. Leap Motion controller application in augmented reality technology

    OpenAIRE

    Artemčiukas, Edgaras; Sakalauskas, Leonidas

    2014-01-01

    In this work the analysis of interaction techniques, devices and its’ possibilities were accomplished. It was determined that the problem, which many researchers tries to solve – more natural interaction between users and computers. Interaction system in augmented reality environment using Leap Motion controller was developed. To achieve this goal augmented reality NyARToolkit and Leap Motion controller libraries were used. Solution ensures extensive information about hand, finger...