WorldWideScience

Sample records for plate agglutination test

  1. Comparison of Rose Bengal Plate Agglutination, Standard tube agglutination and Indirect ELISA tests for detection of Brucella antibodies in Cows and Buffaloes

    Directory of Open Access Journals (Sweden)

    S. N. Ghodasara

    2010-04-01

    Full Text Available A total of 180 serum samples (107 cows, 73 buffaloes from cases of abortion and various reproductive disorders were collected for detection of Brucella antibody by Rose Bengal Plate Agglutination Test (RBPT, Serum Tube Agglutination Test (STAT and indirect- ELISA (i-ELISA. The overall prevalence of brucellosis by RBPT, STAT and i-ELISA were 11.21%, 16.00% and 24.30% in cows 9.59%, 12.33% and 26.03% in buffaloes respectively. Overall seroprevalence of Brucellosis in cases of abortion, R.O.P. by RBPT, STAT and i-ELISA were 11.32%, 16.04% and 32.08% respectively. When three serological tests were compared, seropositivity was found highest by i-ELISA (25%, followed by STAT (14.45% and RBPT (10.56%. The results shows higher prevalence of brucellosis in cases of abortion and R.O.P., while at lower level from various reproductive disorders as detected serologically indicating endemicity of the infection in villages around Anand city, Gujarat. [Vet. World 2010; 3(2.000: 61-64

  2. A comparison of titers of anti-Brucella antibodies of naturally infected and healthy vaccinated cattle by standard tube agglutination test, microtiter plate agglutination test, indirect hemagglutination assay, and indirect enzyme-linked immunosorbent assay

    Directory of Open Access Journals (Sweden)

    Anju Mohan

    2016-07-01

    Full Text Available Aim: We determined the antibody response in cattle naturally infected with brucellosis and normal healthy adult cattle vaccinated during calf hood with strain 19. Materials and Methods: The antibody titers were measured by standard tube agglutination test (STAT, microtiter plate agglutination test (MAT, indirect hemagglutination assay (IHA, and indirect enzyme-linked immunosorbent assay (iELISA as per standard protocols. Results: The mean STAT titers were 1.963±0.345 in infected cattle and 1.200±0.155 in healthy vaccinated cattle. The difference was extremely significant (p<0.0001. The mean MAT titers were 2.244±0.727 in infected cattle and 1.200±0.155 in healthy vaccinated cattle. The difference was very significant (p<0.005. The mean IHA titers in infected cattle were 2.284±0.574, and those in healthy vaccinated cattle were 1.200±0.155. The difference was extremely significant (p=0.0002. However, the difference in mean iELISA titers of infected cattle (1.3678±0.014 and healthy vaccinated cattle (1.367±0.014 was non-significant. The infected animals showed very high titers of agglutinating antibodies compared to the vaccinated animals. However, it cannot be ascertained whether these antibodies are due to vaccine or response to infection. Since the infected animals had been vaccinated earlier, the current infection may suggest that vaccination was unable to induce protective levels of antibody. The heightened antibody response after infection may also indicate a secondary immune response to the antigens common to the vaccine strain and wild Brucella organisms. Conclusion: The brucellosis infected animals showed very high titers of agglutinating antibodies compared to the vaccinated animals.

  3. Application of direct agglutination test (DAT) and fast agglutination screening test (FAST) for sero-diagnosis of visceral leishmaniasis in endemic area of Minas Gerais, Brazil

    NARCIS (Netherlands)

    Silva, Eduardo S.; Schoone, Gerard J.; Gontijo, Celia M. F.; Brazil, Reginaldo P.; Pacheco, Raquel S.; Schallig, Henk D. F. H.

    2005-01-01

    The direct agglutination test (DAT) has proved to be a very important sero-diagnostic tool combining high levels of intrinsic validity and ease of performance. Otherwise, fast agglutination screening test (FAST) utilises only one serum dilution making the test very suitable for the screening of

  4. Seroprevalence of Mycoplasma gallisepticum antibody by ELISA and serum plate agglutination test of laying chicken

    Directory of Open Access Journals (Sweden)

    Md. Zulfekar Ali

    2015-01-01

    Full Text Available Aim: Mycoplasma gallisepticum (MG is important avian pathogen responsible for chronic respiratory disease of chicken and turkeys, which result in large economic loss for the poultry industry. The objectives of this study were determination of seroprevalence of MG antibody of commercial layer chicken at laying period in selected areas of Bangladesh. Materials and Methods: A total of 563 blood samples were collected randomly from selected commercial layer chickens at laying period during the period from July to December, 2013. Indirect enzyme linked immunosorbent assay (iELISA and serum plate agglutination (SPA test were performed to detect the presence of antibodies against MG. Results: Of 563 samples, 64.47% and 56.13% showed an overall prevalence of MG antibodies in iELISA and SPA test respectively. Prevalence of MG was recorded the highest (69.63% at 50-55 weeks of age compared with lowest (53.26% at 56-61 weeks of age (p<0.05. Significant (p<0.05 effect of breed were observed in the seroprevalence of MG infection in layer birds in the present study. The overall, 68.77%, 63.74% and 59.37% prevalence were found respectively in sonali, ISA Brown and White leg horn. The prevalence of MG antibodies was the highest (70.13% in December followed by November (68%, October (65.67%, August (63.46%, September (58.54% and July (51.78% month. The seroprevalence of MG antibodies was higher (69.63% in most of the large flocks and lower (56.82% in small flocks. Conclusion: Therefore, might be suggested that the commercial layer farms should be routinely checked to monitor MG infection and the reactor birds should be culled since MG organism has the potential to transmit vertically. The correlation between MG antibody in month and flock size was not significant (p=0.359 and p=0.868, respectively.

  5. Microbead agglutination based assays

    KAUST Repository

    Kodzius, Rimantas

    2013-01-21

    We report a simple and rapid room temperature assay for point-of-care (POC) testing that is based on specific agglutination. Agglutination tests are based on aggregation of microbeads in the presence of a specific analyte thus enabling the macroscopic observation. Such tests are most often used to explore antibody-antigen reactions. Agglutination has been used for protein assays using a biotin/streptavidin system as well as a hybridization based assay. The agglutination systems are prone to selftermination of the linking analyte, prone to active site saturation and loss of agglomeration at high analyte concentrations. We investigated the molecular target/ligand interaction, explaining the common agglutination problems related to analyte self-termination, linkage of the analyte to the same bead instead of different microbeads. We classified the agglutination process into three kinds of assays: a two- component assay, a three-component assay and a stepped three- component assay. Although we compared these three kinds of assays for recognizing DNA and protein molecules, the assay can be used for virtually any molecule, including ions and metabolites. In total, the optimized assay permits detecting analytes with high sensitivity in a short time, 5 min, at room temperature. Such a system is appropriate for POC testing.

  6. Microbead agglutination based assays

    KAUST Repository

    Kodzius, Rimantas; Castro, David; Foulds, Ian G.; Parameswaran, Ash M.; Sumanpreet, K. Chhina

    2013-01-01

    We report a simple and rapid room temperature assay for point-of-care (POC) testing that is based on specific agglutination. Agglutination tests are based on aggregation of microbeads in the presence of a specific analyte thus enabling

  7. The Classroom-Friendly ABO Blood Types Kit: Blood Agglutination Simulation

    Science.gov (United States)

    Arnold, Savittree Rochanasmita; Kruatong, Tussatrin; Dahsah, Chanyah; Suwanjinda, Duongdearn

    2012-01-01

    The classroom-friendly ABO blood type kit was developed by combining advantages of modelling and a simulation laboratory to teach the topics of ABO blood types and blood transfusion. Teachers can easily simulate the agglutination reaction on a blood type testing plate in the classroom, and show the students how this reaction occurs by using the…

  8. Latex agglutination using the periplasmic proteins antigen of Brucella melitensis is a successful, rapid, and specific serodiagnostic test for ovine brucellosis.

    Science.gov (United States)

    Ismael, Alaa Bassuny; Swelum, Ayman Abdel-Aziz; Mostafa, Salama A-H; Alhumiany, Abdel-Rahman A

    2016-09-01

    Brucellosis, especially caused by Brucella melitensis, is considered the most-widespread zoonosis in the world, particularly in developing countries. This study was planned to develop an accurate test for diagnosis of ovine brucellosis using a specific hot saline extracted soluble Brucella melitensis periplasmic proteins (SBPPs). The efficacy of the latex agglutination test (LAT) using SBPPs compared to the Rose Bengal test (RBT), buffered plate agglutination test (BPAT), serum agglutination test (SAT), and an indirect enzyme-linked immunosorbent assay (i-ELISA) was evaluated in the field diagnosis of ovine brucellosis. The test performance was evaluated by estimating sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), disease prevalence (DP), positive likelihood ratio (PLR), and negative likelihood ratio (NLR) using test agreement and bacteriological culture in 1777 samples. The false-positive result was significantly (P ⩽0.05) lower in LAT than RBT, BPAT, SAT, and i-ELISA. With reference to test agreement, the Se, Sp, PPV, and PLR were highest (P ⩽0.05) in LAT 99.33%, 99.88%, 98.68%, and 827.25%, respectively. With reference to bacteriological culture, the LAT and i-ELISA tests showed a significant difference in Se with SAT. However, no significant difference in specificity was detected. The DP was 8.44% in the five tests. In conclusion, LAT using SBPPs of B. melitensis could be a suitable serodiagnostic field test for ovine brucellosis, with high sensitivity and specificity. © The Author(s) 2016.

  9. Latex agglutination test (LAT) for the diagnosis of typhoid fever.

    Science.gov (United States)

    Sahni, Gopal Shankar

    2013-06-01

    The efficacy of latex agglutination test in the rapid diagnosis of typhoid fever was studied and the result compared with that of blood culture. This study included 80 children suffering from typhoid fever, among which 40 were confirmed by blood culture isolation and 40 had possible typhoid fever based on high Widal's titre (a four-fold rise in the titre of antibody to typhi "O" and "H" antigen was considered as a positive Widal's test result). Eighty children, 40 with febrile illness confirmed to be other than typhoid and 40 normal healthy children were used as negative controls. The various groups were: (i) Study group ie, group I had 40 children confirmed by culture isolation of Salmonella typhi(confirmed typhoid cases). (ii) Control groups ie, (a) group II with 40 febrile controls selected from paediatrics ward where cause other than S typhi has been established, (b) group III with 40 afebrile healthy controls that were siblings of the children admitted in paediatric ward for any reason with no history of fever and TAB vaccination in the last one year, and (c) group IV with 40 children with high Widal's titre in paired sera sample. Widal's test with paired sera with a one week interval between collections were done in all 40 patients. Latex aggtutination test which could detect 900 ng/ml of antigen as observed in checker board titration, was positive in all 40 children from group I who had positive blood culture and in 30 children from group IV who had culture negative and had high Widal's titre positive. Latex agglutination test was positive in 4 children in group II and none in group III. Using blood culture positive cases as true positive and children in groups II and III as true negative, the test had a sensitivity of 100% and specificity of 96%. Latex agglutination test was found to be significantly sensitive (100%) and specific (96%) and could detect 75% more cases in group IV (possible typhoid cases). Thus latex agglutination test can be used for rapid

  10. Comparison of agglutination test, microscopy and nPCR for ...

    African Journals Online (AJOL)

    action (nPCR) for the detection of T. gondii infection in mice (n=399) inoculated with heart .... Direct Agglutination Test (DAT) (Toxo screen DA, Biomerieux®, France) fol- ... 0.3 µl external forward Primer (50 µM), 0.3 µl external reverse Primer.

  11. Development of a fast agglutination screening test (FAST) for the detection of anti-Leishmania antibodies in dogs

    NARCIS (Netherlands)

    Schallig, H. D. F. H.; Schoone, G. J.; Beijer, E. G. M.; Kroon, C. C. M.; Hommers, M.; Ozbel, Y.; Ozensoy, S.; da Silva, E. S.; Cardoso, L. M.; da Silva, E. D.

    2002-01-01

    A fast agglutination screening test (FAST) for the detection of anti-Leishinania antibodies in serum samples from dogs with visceral leishmamosis was developed. The test is based on the direct agglutination test (DAT), but combines a higher parasite concentration with a smaller test volume. In

  12. Serotyping of Actinobacillus pleuropneumoniae serotype 5 strains using a monoclonal-based polystyrene agglutination test

    DEFF Research Database (Denmark)

    Dubreuil, J.D.; Letellier, A.; Stenbæk, Eva

    1996-01-01

    A polystyrene agglutination test has been developed for serotyping Actinobacillus pleuropneumoniae serotype 5a and 5b strains. Protein A-coated polystyrene microparticles were sensitized with a murine monoclonal antibody recognizing an epitope on serotype 5 LPS-O chain as shown by SDS-PAGE and We......A polystyrene agglutination test has been developed for serotyping Actinobacillus pleuropneumoniae serotype 5a and 5b strains. Protein A-coated polystyrene microparticles were sensitized with a murine monoclonal antibody recognizing an epitope on serotype 5 LPS-O chain as shown by SDS...... suspension of bacterial cells grown for 18 h. All A, pleuropneumoniae strains had been previously serotyped using standard procedures, The polystyrene agglutination test was rapid (less than 3 min) and easy to perform. Overall a very good correlation (97.3%) with the standard techniques was found...

  13. [Diagnosis of human brucellosis. Role of pH in the seroagglutination test and influence of pH on the agglutinating activity of IgM, IgG and IgA antibodies].

    Science.gov (United States)

    Rubio Vallejo, Manuel; del Pozo, José L; Del Pozo León, José Luis; Hernández-Molina, Juan Manuel; Dorronsoro Ibero, Inés; Marrodán Ciordia, Teresa; Díaz García, Ramón

    2002-04-01

    To evaluate the role of pH in the seroagglutination test (SAT)and Rose Bengal (RB) test, and to determine the influence of pH on the agglutinating activity of IgM, IgG and IgA antibodies. The SAT was performed at pH 7.2 or pH 5.0 in standard microtiter-type polystyrene plates using Ring Test antigen or the Brucella suspension (BRUCAPT) provided in the Brucellacapt kits. Specific antibodies against native hapten were determined by radial immunodiffusion. Additionally, IgG, IgA and IgM fractions were separated from 8 sera by absorption chromatography and their agglutinating capacity was studied at pH 7.2 and 5.0. We studied 72 sera from patients with clinical brucellosis taken at the time of hospitalization, 16 from persons in contact with infected animals, and 16 from healthy donors. SAT results at pH 5.0 correlated with those obtained with the Rose Bengal test. Four Rose Bengal-positive sera were found to be SAT-negative at pH 7.2 and SAT-positive at pH 5.0. SAT performed at pH 5.0 with BRUCAPT antigen yielded higher titers than tests performed at pH 7.2 or 5.0 with Ring Test antigen (p IgA fractions were SAT-negative at pH 7.2 and SAT-positive at pH 5.0; the other 5 agglutinated at both pH conditions and were DTT-sensitive. All IgA fractions but one were positive by Rose Bengal. Agglutinating activity of the IgM fraction was not affected by pH. The SAT performed with the buffer and antigen suspension included in the Brucellacapt kit (pH 5.0) is highly useful for detecting agglutinating and non-agglutinating antibodies at pH 7.2.

  14. Typhoid fever in a Tertiary Hospital in Nigeria: Another look at the Widal agglutination test as a preferred option for diagnosis.

    Science.gov (United States)

    Enabulele, Osahon; Awunor, Simeon Nyemike

    2016-01-01

    Single Widal agglutination test rather than blood culture, is commonly employed to diagnose typhoid fever in Nigeria. We took another look at the Widal agglutination test as a preferred option for diagnosis of typhoid fever by determining the specificity and sensitivity of Widal agglutination test in febrile adult patients. Two hundred and seventy-one blood samples from consecutive adults (>18 years) with febrile illness attending the General Practice Clinic of the University of Benin Teaching Hospital were tested using the Widal agglutination test, blood culture, and malaria parasite test on each sample to establish the diagnosis of typhoid fever. Of the 271 blood samples 124 (45.76%) were positive following a Widal agglutination test, 60 (22.10%) blood samples grew Salmonella organisms on blood culture while 55 (20.29%) blood samples showed a co-infection of typhoid fever and malaria. A sensitivity of 35%, specificity of 51%, positive predictive value of 17%, and a negative predictive value of 73% were observed for Widal agglutination test as a diagnostic modality for typhoid fever infection. A single Widal agglutination test is not a valid diagnostic option for typhoid fever while co-infection with malaria parasite is the preponderant microbiological finding in typhoid fever infections. The severity of malaria parasitemia is associated with positive titers on Widal test.

  15. DNA & Protein detection based on microbead agglutination

    KAUST Repository

    Kodzius, Rimantas

    2012-06-06

    We report a simple and rapid room temperature assay for point-of-care (POC) testing that is based on specific agglutination. Agglutination tests are based on aggregation of microparticles in the presence of a specific analyte thus enabling the macroscopic observation. Agglutination-based tests are most often used to explore the antibody-antigen reactions. Agglutination has been used for mode protein assays using a biotin/streptavidin two-component system, as well as a hybridization based two-component assay; however, as our work shows, two-component systems are prone to self-termination of the linking analyte and thus have a lower sensitivity. Three component systems have also been used with DNA hybridization, as in our work; however, their assay requires 48 hours for incubation, while our assay is performed in 5 minutes making it a real candidate for POC testing. We demonstrate three assays: a two-component biotin/streptavidin assay, a three-component hybridization assay using single stranded DNA (ssDNA) molecules and a stepped three-component hybridization assay. The comparison of these three assays shows our simple stepped three-component agglutination assay to be rapid at room temperature and more sensitive than the two-component version by an order of magnitude. An agglutination assay was also performed in a PDMS microfluidic chip where agglutinated beads were trapped by filter columns for easy observation. We developed a rapid (5 minute) room temperature assay, which is based on microbead agglutination. Our three-component assay solves the linker self-termination issue allowing an order of magnitude increase in sensitivity over two–component assays. Our stepped version of the three-component assay solves the issue with probe site saturation thus enabling a wider range of detection. Detection of the agglutinated beads with the naked eye by trapping in microfluidic channels has been shown.

  16. Rapid detection of microalbuminuria in diabetic patients by an agglutination inhibition test

    International Nuclear Information System (INIS)

    Giampietro, O.; Miccoli, R.; Di Palma, L.; Bertolotto, A.; Anichini, R.; Navalesi, R.; Clerico, A.

    1986-01-01

    Subclinical elevation of urinary albumin excretion (UAlbE) early in the course of diabetes mellitus has been suggested to predict later clinical proteinuria and mortality. UAlbE is currently measured using radioimmunoassay (RIA) or radial immunodiffusion methods. However, these procedures are expensive and time-consuming and cannot be used as screening methods. Recently, an agglutination test (AT) has been suggested as a routinary method for the screening of microalbuminuria in diabetic patients. In this paper the results obtained are compared with an AT procedure and RIA method in a screening program of microproteinuria in diabetic patients. An immunological test (a latex agglutination assay) for the analysis of albuminura is used, which human albumin was adsorbed to latex beads (about 0.3 μl of a urine sample. Urine samples containing an albumin concentration >40 μg/ml were found to inhibit the agglutination of latex beads with antiserum. The RIA and AT results showed good agreement when urine samples were assayed soon after collection or after a short period of storage (≤3 weeks at -20 grade centigrades). The AT procedure has been adjusted in order to give a positive response (no agglutination) over the range of supranormal concentrations of urinary albumin (>40 μg/ml), which are on the other hand undetectable by Albustix. In addition, it is possible to perform a semiquantitative test using various dilutions of urine samples with albumin concentration > 40 μg/ml, so to estimate approximately the UAlbE. The AT method is simple, fast and specific, and has proved to be useful for the identification of diabetic patients at risk for developing clinical nephropathy. Therefore, it may be used in screening programs for diabetic microproteinuria

  17. Comparative experiments for tube agglutination test of pullorum antiserum with gamma ray Co/sup 60/ irradiated salmonella pullorum

    Energy Technology Data Exchange (ETDEWEB)

    Seo, B K [City Univ. of Seoul, Seoul (Republic of Korea)

    1976-01-01

    An agglutinability between naturally infected positive chicken serum of pullorum disease and hyperimmunized rabbit antiserum was compared. And the following results were obtained and summarized. On the agglutinability, Salmonella pullorum antigen which irradiated gamma-ray was better than another both formalized and heated antigen. Time of judgemented as positive titer in the tube agglutination test to the naturally infected positive chicken serum was it most suitable for 12 hours at 37/sup 0/C. Agglutination titer of positive immune chicken serum against gamma-ray irradiate Salmonella pullorum were as 320 approximately 640x.

  18. THE INVESTIGATION OF BRUCELLA ANTIBODY WITH MILK RING TEST AND AGGLUTINATION TEST IN MILK COLLECTED FROM SAMSUN REGION

    Directory of Open Access Journals (Sweden)

    Goknur TERZI

    2006-06-01

    Full Text Available In this study Brucella antibodies were investigated with agglutination test (Whey-AT and Milk Ring Test (MRT in a total of 100 milk samples as 50 of cow milk and 50 of goat milk collected from center and villages of Samsun. According to MRT Brucella antibodies was positive at 10 samples (20 % of cow milk and 6 samples (12 % of goat milk. In cow milk, 4 (8 % positive, 3 (6 % suspicious and 43 (86 % negative samples; in goat milk 3 (6 % positive, 2 (4 % suspicious and 45 (90 % negative samples were determined according to antibodies titre of serum agglutination test (Whey-AT. [TAF Prev Med Bull 2006; 5(3.000: 196-203

  19. Rapid latex agglutination test for the serodiagnosis of human brucellosis

    NARCIS (Netherlands)

    Abdoel, Theresia H.; Smits, Henk L.

    2007-01-01

    We developed and evaluated a user-friendly latex agglutination assay for the serodiagnosis of human brucellosis. The assay was obtained by coating colored latex beads with Brucella lipopolysaccharides and drying of the activated beads onto white agglutination cards. Individual cards were sealed in a

  20. DNA & Protein detection based on microbead agglutination

    KAUST Repository

    Kodzius, Rimantas; Castro, David; Foulds, Ian G.; Parameswaran, Ash M.; Sumanpreet, K. Chhina

    2012-01-01

    the macroscopic observation. Agglutination-based tests are most often used to explore the antibody-antigen reactions. Agglutination has been used for mode protein assays using a biotin/streptavidin two-component system, as well as a hybridization based two

  1. Microscopic agglutination test on captive rattlesnakes : Data on serovars and titers

    Directory of Open Access Journals (Sweden)

    T.C.S. Rodrigues

    2016-06-01

    Full Text Available The microscopic agglutination test (MAT is considered the “golden standard” leptospirosis serodiagnostic test, but there is little information about it as it pertains to snakes. To fill this information gap, we provide data on serovars and titers of fifty-six Crotalus durissus collilineatus sera samples that tested positive by MAT (10.1016/j.actatropica.2016.02.006 (Rodrigues et al., 2016 [5]. These data are presented in a table, along with a description of the methodology used for sample collection and serologic testing.

  2. [Detection of anti-Leptospira antibodies in sera of patients in the latex agglutination test].

    Science.gov (United States)

    Volina, E G; Sarukhanova, L E; Iashina, N V; Prokopov, N I; Shkarlat, P E; Barysheva, I V

    2001-01-01

    The results of the preliminary evaluation of the sensitivity and specificity of the newly developed diagnostic test based on the determination of genus-specific antibodies to leptospires in the latex agglutination test, are presented. This test makes it possible to detect anti-Leptospira antibodies of any serogroup. The advantages of the developed test have been determined.

  3. A comparison of sperm agglutination and immobilization assays with a quantitative ELISA for anti-sperm antibody in serum.

    Science.gov (United States)

    Lynch, D M; Leali, B A; Howe, S E

    1986-08-01

    An enzyme-linked immunosorbent assay (ELISA) that quantitates antisperm antibody in serum was compared with standard sperm agglutination and immobilization assays with the use of sera from 40 normal and 292 subfertile individuals. Quantitation of the assay was accomplished by standardizing assay parameters, including the incorporation of a standard reference curve, the number of whole target sperm, the optimal dilution of serum, the selection of microtiter plate, and the time and temperatures involved in the adsorption and incubation phases. With this method, the level of antisperm antibody binding to target sperm in 40 normal fertile individuals was found to be 2.3 (+/- 1.1 standard deviation [SD]) fg immunoglobulin (Ig)/sperm. An increased mean level of 7.4 +/- 3.7 fg Ig/sperm was determined in 84 infertile patients with positive agglutination and/or immobilization tests. In 208 individuals with negative agglutination and immobilization tests the mean concentration of antisperm antibody was 2.5 +/- 1.3 fg Ig/sperm. Postvasectomy patients assayed by this method had a mean Ig binding value of 7.1 +/- 2.4 fg Ig/sperm. The infertile group with positive agglutination and/or immobilization tests had a significantly higher mean antisperm antibody level than the normal fertile group, according to the Student's t-test for independent samples (P less than 0.001). This indirect serum-based assay reproducibly quantitates antisperm antibody binding to whole target sperm, suggests the normal and abnormal levels of antisperm antibody, and correlates with standard functional assays.

  4. Good agreement of conventional and gel-based direct agglutination test in immune-mediated haemolytic anaemia

    NARCIS (Netherlands)

    Piek, C.J.; Teske, E.; van Leeuwen, M.W.; Day, M.J.

    2012-01-01

    Abstract Background The aim of this study was to compare a gel-based test with the traditional direct agglutination test (DAT) for the diagnosis of immune-mediated haemolytic anaemia (IMHA). Methods Canine (n = 247) and feline (n = 74) blood samples were submitted for DAT testing to two

  5. Determination of immune status in dogs against CPV-2 by recombinant protein based latex agglutination test.

    Science.gov (United States)

    Thomas, Jobin; Singh, Mithilesh; Goswami, T K; Glora, Philma; Chakravarti, Soumendu; Chander, Vishal; Upmanyu, Vikramaditya; Verma, Suman; Sharma, Chhavi; Mahendran, K

    2017-09-01

    Canine parvoviral enteritis is a highly contagious viral illness caused by canine parvovirus-2 (CPV-2) which affects puppies of mainly 6-20 weeks of age. Vaccination is pivotal in preventing and controlling CPV-2 infection. Determination of antibody status is a critical determinant for successful vaccination. The hemagglutination inhibition (HI) test is 'gold standard' test for quantification of antibodies specific to CPV-2, although the execution of this test is not feasible under field conditions. The present study was undertaken to develop a point of care testing to determine immune status prior to CPV-2 vaccination or to detect seroconversion in immunized dogs by latex agglutination test (LAT) using recombinant antigen. Truncated portion of VP2 protein (tVP2) of CPV-2 was selected on the basis of antigenic indices, overexpressed the recombinant protein in E. coli system and was subsequently used in development of LAT. A total of 59 serum samples obtained from vaccinated (n = 54) and healthy unvaccinated (n = 5) dogs were tested. The positivity was observed in 85% (46/54) of these dogs with varying agglutination pattern. The overall sensitivity and specificity of latex agglutination test in comparison to HI test was recorded as 90% and 88% respectively with an agreement value of 90% (CI = 95%). Copyright © 2017 International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.

  6. Rapid detection of microalbuminuria in diabetic patients by an agglutination inhibition test. Comparison with radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Giampietro, O; Miccoli, R; Di Palma, L; Bertolotto, A; Anichini, R; Navalesi, R; Clerico, A

    1986-01-01

    Subclinical elevation of urinary albumin excretion (UAlbE) early in the course of diabetes mellitus has been suggested to predict later clinical proteinuria and mortality. UAlbE is currently measured using radioimmunoassay (RIA) or radial immunodiffusion methods. However, these procedures are expensive and time-consuming and cannot be used as screening methods. Recently, an agglutination test (AT) has been suggested as a routinary method for the screening of microalbuminuria in diabetic patients. In this paper the results obtained are compared with an AT procedure and RIA method in a screening program of microproteinuria in diabetic patients. An immunological test (a latex agglutination assay) for the analysis of albuminura is used, which human albumin was adsorbed to latex beads (about 0.3 ..mu..l of a urine sample. Urine samples containing an albumin concentration >40 ..mu..g/ml were found to inhibit the agglutination of latex beads with antiserum. The RIA and AT results showed good agreement when urine samples were assayed soon after collection or after a short period of storage (less than or equal to3 weeks at -20 grade centigrades). The AT procedure has been adjusted in order to give a positive response (no agglutination) over the range of supranormal concentrations of urinary albumin (>40 ..mu..g/ml), which are on the other hand undetectable by Albustix. In addition, it is possible to perform a semiquantitative test using various dilutions of urine samples with albumin concentration > 40 ..mu..g/ml, so to estimate approximately the UAlbE. The AT method is simple, fast and specific, and has proved to be useful for the identification of diabetic patients at risk for developing clinical nephropathy. Therefore, it may be used in screening programs for diabetic microproteinuria. 21 refs.

  7. Rapid detection of methicillin resistance in Staphylococcus aureus isolates by the MRSA-screen latex agglutination test

    NARCIS (Netherlands)

    W.B. van Leeuwen (Willem); C. van Pelt (Cindy); A. Luijendijk (Ad); H.A. Verbrugh (Henri); W.H.F. Goessens (Wil)

    1999-01-01

    textabstractThe slide agglutination test MRSA-Screen (Denka Seiken Co., Niigata, Japan) was compared with the mecA PCR ("gold standard") for the detection of methicillin resistance in Staphylococcus aureus. The MRSA-Screen test detected the penicillin-binding protein 2a

  8. Diagnostic value of latex agglutination test in diagnosis of acute bacterial meningitis

    Directory of Open Access Journals (Sweden)

    Syeda Fasiha Mohammadi

    2013-01-01

    Full Text Available Objectives: To know the incidence of bacterial meningitis in children below five years of age. To compare conventional culture and antigen detection methods ( Latex agglutination test. Materials and Methods: 100 CSF samples of clinically suspected meningitis cases in children below 5 years of age were included. The samples were subjected to cell count, Gram stain, culture and LAT. The organisms isolated in the study were characterized according to standard procedures. Results: Of the 100 cases studied, 31 cases were diagnosed as ABM by Gram stain, culture and latex agglutination test as per WHO criteria. The hospital frequency of ABM was 1.7%. 15 (48.38 cases were culture positive. Gram stain was positive in 22(70.96 cases and LAT in 17(54.83 cases. Haemophilus influenzae was the most common causative agent of acute bacterial meningitis followed by S.pneumoniae. Case fatality rate was 45.16%.The sensitivity and specificity of LAT was 66.66% and 87.91% respectively. Conclusion : Bacterial meningitis is a medical emergency and early diagnosis and treatment is life saving and reduces chronic morbidity. LAT was more sensitive compared to conventional Gram stain and Culture technique in identifying the fastidious organisms like H.influenzae, S.pneumoniae and Group B Streptococcus. However, the combination of Gram stain, Culture and LAT proved to be more productive than any of the single tests alone.

  9. Leishmaniasis Direct Agglutination Test: Using Pictorials as Training Materials to Reduce Inter-Reader Variability and Improve Accuracy

    NARCIS (Netherlands)

    Adams, Emily R.; Jacquet, Diane; Schoone, Gerard; Gidwani, Kamlesh; Boelaert, Marleen; Cunningham, Jane

    2012-01-01

    Background: The Direct Agglutination Test (DAT) has a high diagnostic accuracy and remains, in some geographical areas, part of the diagnostic algorithm for Visceral Leishmaniasis (VL). However, subjective interpretation of results introduces potential for inter-reader variation. We report an

  10. The direct agglutination test as an alternative method for the diagnosis of canine and human visceral leishmaniasis

    NARCIS (Netherlands)

    Terán-Angel, Guillermo; Schallig, Henk; Zerpa, Olga; Rodríguez, Vestalia; Ulrich, Marian; Cabrera, Maira

    2007-01-01

    Visceral leishmaniasis is the most severe clinical form of leishmaniasis and is often fatal without proper treatment. Therefore, early and accurate diagnosis is important, but often difficult in endemic areas. The aim was to evaluate a direct agglutination test as a potential visceral leishmaniasis

  11. An influenza A virus agglutination test using antibody-like polymers.

    Science.gov (United States)

    Sukjee, Wannisa; Thitithanyanont, Arunee; Wiboon-Ut, Suwimon; Lieberzeit, Peter A; Paul Gleeson, M; Navakul, Krongkaew; Sangma, Chak

    2017-10-01

    Antibodies are commonly used in diagnostic routines to identify pathogens. The testing protocols are relatively simple, requiring a certain amount of a specific antibody to detect its corresponding pathogen. Antibody functionality can be mimicked by synthesizing molecularly imprinted polymers (MIPs), i.e. polymers that can selectively recognize a given template structure. Thus, MIPs are sometimes termed 'plastic antibody (PA)'. In this study, we have synthesized new granular MIPs using influenza A virus templates by precipitation polymerization. The selective binding of influenza A to the MIP particles was assessed and subsequently contrasted with other viruses. The affinities of influenza A virus towards the MIP was estimated based on an agglutination test by measuring the amount of influenza subtypes absorbed onto the MIPs. The MIPs produced using the H1N1 template showed specific reactivity to H1N1 while those produced using H5N1 and H3N2 templates showed cross-reactivity.

  12. Sero-epidemiological assessment and diagnosis of visceral leishmaniasis in an endemic locality using Fast Agglutination Screening Test (FAST)

    NARCIS (Netherlands)

    Hailu, A.; Kroon, C. C. M.; Schoone, G. J.; Berhe, N.; Schallig, H. D. F. H.; Kager, P. A.

    2002-01-01

    The Fast Agglutination Screening Test (FAST) was employed on sera obtained from an endemic area of visceral leishmaniasis in southwestern Ethiopia, in February 2000. The study involved (i) active case detection among 1575 residents of two villages; and (ii) passive case detection in an outpatient

  13. 9 CFR 147.1 - The standard tube agglutination test. 1

    Science.gov (United States)

    2010-01-01

    ... may be done with a suitable pencil on etched portions of the tube, or by means of fast-gum labels. (3..., high agglutinability, but are not sensitive to negative and nonspecific sera. The stock cultures may be... for at least 20 hours at 37 °C. (h) The results shall be recorded as: N, or − (negative) when the...

  14. Reverse-Transcriptase PCR Detection of Leptospira: Absence of Agreement with Single-Specimen Microscopic Agglutination Testing.

    Science.gov (United States)

    Waggoner, Jesse J; Balassiano, Ilana; Mohamed-Hadley, Alisha; Vital-Brazil, Juliana Magalhães; Sahoo, Malaya K; Pinsky, Benjamin A

    2015-01-01

    Reference diagnostic tests for leptospirosis include nucleic acid amplification tests, bacterial culture, and microscopic agglutination testing (MAT) of acute and convalescent serum. However, clinical laboratories often do not receive paired specimens. In the current study, we tested serum samples using a highly sensitive real-time nucleic acid amplification test for Leptospira and compared results to MAT performed on the same specimens. 478 serum samples from suspected leptospirosis cases in Rio de Janeiro were tested using a real-time RT-PCR for the diagnosis of leptospirosis, malaria and dengue (the Lepto-MD assay). The Lepto-MD assay detects all species of Leptospira (saprophytic, intermediate, and pathogenic), and in the current study, we demonstrate that this assay amplifies both Leptospira RNA and DNA. Dengue virus RNA was identified in 10 patients, and no cases of malaria were detected. A total of 65 samples (13.6%) were positive for Leptospira: 35 samples (7.3%) in the Lepto-MD assay, 33 samples (6.9%) by MAT, and 3 samples tested positive by both (kappa statistic 0.02). Poor agreement between methods was consistent regardless of the titer used to define positive MAT results or the day of disease at sample collection. Leptospira nucleic acids were detected in the Lepto-MD assay as late as day 22, and cycle threshold values did not differ based on the day of disease. When Lepto-MD assay results were added to the MAT results for all patients in 2008 (n=818), the number of detected leptospirosis cases increased by 30.4%, from 102 (12.5%) to 133 (16.3%). This study demonstrates a lack of agreement between nucleic acid detection of Leptospira and single-specimen MAT, which may result from the clearance of bacteremia coinciding with the appearance of agglutinating antibodies. A combined testing strategy for acute leptospirosis, including molecular and serologic testing, appears necessary to maximize case detection.

  15. ELISA Cut-off Point for the Diagnosis of Human Brucellosis; a Comparison with Serum Agglutination Test

    Directory of Open Access Journals (Sweden)

    Anahita Sanaei Dashti

    2012-03-01

    Full Text Available Background: Brucellosis is a world-wide disease, which has a diverse clinical manifestation, and its diagnosis has to be proven by laboratory data. Serum agglutination test (SAT is the most-widely used test for diagnosing brucellosis. The enzyme linked immunosorbent assay (ELISA can also determine specific antibody classes against brucella. It is a sensitive, simple and rapid test, which could be an acceptable alternative to SAT with fewer limitations, however, like any other new test it should be further evaluated and standardized for various populations. This study was planned to determine an optimal cut-off point, for ELISA which would offer maximum sensitivity and specificity for the test when compared to SAT.Methods: Four hundred and seven patients with fever and other compatible symptoms of brucellosis were enrolled in the study. Serum agglutination test, 2-Mercaptoethanol test, and ELISA were performed on their sera. Results: The cut-off point of 53 IU/ml of ELISA-IgG yielded the maximal sensitivity and specificity comparing to the other levels of ELISA-IgG, and was considered the best cut off-point of ELISA-IgG to diagnose acute brucellosis. At this cut-off, the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio were 84.09%, 85.38%, 62.20, 94.90, 5.75, 0.18, respectively.Conclusion: The best cut-off point of ELISA-IgG is 53 IU/ml, which yields the maximal sensitivity and specificity to diagnose acute brucellosis.

  16. Evaluation of efficacy of some serological tests used for diagnosis of ...

    African Journals Online (AJOL)

    These samples were subjected to the different serological tests including Rose Bengal plate antigen test, Tube Agglutination test, Rivanol test, Indirect Enzyme Linked Immunosorbent Assay and Competitive Enzyme Linked Immunosorbent Assay. Statistical analysis of the obtained results in different cattle groups was ...

  17. Making antigen of trypanosoma evansi and its examination by catt (card agglutination test) method

    International Nuclear Information System (INIS)

    Arifin, M; Irtisam; Estikoma Dyah; Yulia Ernawati; Boky, J.T

    1998-01-01

    An experiment was carried out for making antigen (Ag) of T. evansi by using experimental animals rats and guinea pigs for for developing parasites, and in cattle for making immune serum and normal serum. The parasites were irradiated by gamma rays ( 60 Co) at a dose of 300 Gy. The determination of antigen was done by using Card Agglutination Test (CATT) to the field samples serum of cattle. The results obtained showed that antigen was good enough potently and stable at minus 70 0 C storage during five months. (author)

  18. High Fidelity, High Volume Agglutinate Manufacturing Process, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Up to 65% of the lunar soils are comprised of agglutinates. Although the importance of agglutinate in simulants is often debated, the fact is that agglutinates...

  19. Comparison of Brucella immunoglobulin M and G flow assays with serum agglutination and 2-mercaptoethanol tests in the diagnosis of brucellosis

    NARCIS (Netherlands)

    Zeytinoğlu, Ayşin; Turhan, Ajda; Altuğlu, Imre; Bilgiç, Altinay; Abdoel, Theresia H.; Smits, Henk L.

    2006-01-01

    The diagnostic value of Brucella IgM/IgG flow assays was evaluated in comparison with serum agglutination and 2-mercaptoethanol tests by testing a selection of serum samples submitted to the laboratory because of clinical suspicion of brucellosis. All 39 admission and 11 follow-up samples that

  20. Towards a high throughput droplet-based agglutination assay

    KAUST Repository

    Kodzius, Rimantas; Castro, David; Foulds, Ian G.

    2013-01-01

    This work demonstrates the detection method for a high throughput droplet based agglutination assay system. Using simple hydrodynamic forces to mix and aggregate functionalized microbeads we avoid the need to use magnetic assistance or mixing structures. The concentration of our target molecules was estimated by agglutination strength, obtained through optical image analysis. Agglutination in droplets was performed with flow rates of 150 µl/min and occurred in under a minute, with potential to perform high-throughput measurements. The lowest target concentration detected in droplet microfluidics was 0.17 nM, which is three orders of magnitude more sensitive than a conventional card based agglutination assay.

  1. Towards a high throughput droplet-based agglutination assay

    KAUST Repository

    Kodzius, Rimantas

    2013-10-22

    This work demonstrates the detection method for a high throughput droplet based agglutination assay system. Using simple hydrodynamic forces to mix and aggregate functionalized microbeads we avoid the need to use magnetic assistance or mixing structures. The concentration of our target molecules was estimated by agglutination strength, obtained through optical image analysis. Agglutination in droplets was performed with flow rates of 150 µl/min and occurred in under a minute, with potential to perform high-throughput measurements. The lowest target concentration detected in droplet microfluidics was 0.17 nM, which is three orders of magnitude more sensitive than a conventional card based agglutination assay.

  2. Agglutinating antibodies against pathogenic Leptospira in healthy dogs and horses indicate common exposure and regular occurrence of subclinical infections

    NARCIS (Netherlands)

    D.J. Houwers; M.G.A. Goris (Marga); T.H. Abdoel (Theresia); J.A. Kas (Jeroen); S.S. Knobbe (Sandra); A.M. van Dongen (Astrid); F.E. Westerduin (Fenna); W.R. Klein (Wim); R.A. Hartskeerl (Rudy)

    2011-01-01

    textabstractIn order to get insight in the level of exposure to pathogenic Leptospira under the moderate sea climate conditions in the Netherlands, healthy dogs and horses were tested for antibodies using the Microscopic Agglutination Test (MAT). 55% of 198 dogs tested had agglutinating antibodies

  3. A study of the incubation of microbead agglutination assays in a microfluidic system

    KAUST Repository

    Castro, David

    2016-12-19

    This work reports on a quantitative study of the incubation of a microbead-based agglutination assay inside a microfluidic system. In this system, a droplet (1.25µL) consisting of a mixture of functionalized microbeads and analyte is flowed through a 0.51mm internal diameter silicone tube. Hydrodynamic forces alone produce a very efficient mixing of the beads within the droplet. We tested the agglutination at different speeds and show a robust response at the higher range of speeds (150 – 200µL/min), while also reaching a completion in the agglutination process. At these velocities, a length of 180cm is shown to be sufficient to confidently measure the agglutination assay, which takes between 2.5 – 3 minutes. This high throughput quantification method has the potential of accelerating the measurements of various types of biomarkers, which can greatly benefit the fields of biology and medicine.

  4. Good agreement of conventional and gel-based direct agglutination test in immune-mediated haemolytic anaemia

    Directory of Open Access Journals (Sweden)

    Piek Christine J

    2012-02-01

    Full Text Available Abstract Background The aim of this study was to compare a gel-based test with the traditional direct agglutination test (DAT for the diagnosis of immune-mediated haemolytic anaemia (IMHA. Methods Canine (n = 247 and feline (n = 74 blood samples were submitted for DAT testing to two laboratories. A subset of canine samples was categorized as having idiopathic IMHA, secondary IMHA, or no IMHA. Results The kappa values for agreement between the tests were in one laboratory 0.86 for canine and 0.58 for feline samples, and in the other 0.48 for canine samples. The lower agreement in the second laboratory was caused by a high number of positive canine DATs for which the gel test was negative. This group included significantly more dogs with secondary IMHA. Conclusions The gel test might be used as a screening test for idiopathic IMHA and is less often positive in secondary IMHA than the DAT.

  5. Leishmaniasis direct agglutination test: using pictorials as training materials to reduce inter-reader variability and improve accuracy.

    Directory of Open Access Journals (Sweden)

    Emily R Adams

    Full Text Available BACKGROUND: The Direct Agglutination Test (DAT has a high diagnostic accuracy and remains, in some geographical areas, part of the diagnostic algorithm for Visceral Leishmaniasis (VL. However, subjective interpretation of results introduces potential for inter-reader variation. We report an assessment of inter-laboratory agreement and propose a pictorial-based approach to standardize reading of the DAT. METHODOLOGY: In preparation for a comparative evaluation of immunochromatographic diagnostics for VL, a proficiency panel of 15 well-characterized sera, DAT-antigen from a single batch and common protocol was sent to nine laboratories in Latin-America, East-Africa and Asia. Agreement (i.e., equal titre or within 1 titer with the reading by the reference laboratory was computed. Due to significant inter-laboratory disagreement on-site refresher training was provided to all technicians performing DAT. Photos of training plates were made, and end-titres agreed upon by experienced users of DAT within the Visceral-Leishmaniasis Laboratory-Network (VL-LN. RESULTS: Pre-training, concordance in DAT results with reference laboratories was only 50%, although agreement on negative sera was high (94%. After refresher training concordance increased to 84%; agreement on negative controls increased to 98%. Variance in readings significantly decreased after training from 3.3 titres to an average of 1.0 titre (two-sample Wilcoxon rank-sum (Mann-Whitney test (z = -3,624 and p = 0.0003. CONCLUSION: The most probable explanation for disagreement was subjective endpoint reading. Using pictorials as training materials may be a useful tool to reduce disparity in results and promote more standardized reading of DAT, without compromising diagnostic sensitivity.

  6. Red Blood Cell Agglutination for Blood Typing Within Passive Microfluidic Biochips.

    Science.gov (United States)

    Huet, Maxime; Cubizolles, Myriam; Buhot, Arnaud

    2018-04-19

    Pre-transfusion bedside compatibility test is mandatory to check that the donor and the recipient present compatible groups before any transfusion is performed. Although blood typing devices are present on the market, they still suffer from various drawbacks, like results that are based on naked-eye observation or difficulties in blood handling and process automation. In this study, we addressed the development of a red blood cells (RBC) agglutination assay for point-of-care blood typing. An injection molded microfluidic chip that is designed to enhance capillary flow contained anti-A or anti-B dried reagents inside its microchannel. The only blood handling step in the assay protocol consisted in the deposit of a blood drop at the tip of the biochip, and imaging was then achieved. The embedded reagents were able to trigger RBC agglutination in situ, allowing for us to monitor in real time the whole process. An image processing algorithm was developed on diluted bloods to compute real-time agglutination indicator and was further validated on undiluted blood. Through this proof of concept, we achieved efficient, automated, real time, and quantitative measurement of agglutination inside a passive biochip for blood typing which could be further generalized to blood biomarker detection and quantification.

  7. Evaluation of latex agglutination test (KAtex) for early diagnosis of kala-azar.

    Science.gov (United States)

    Ahsan, M M; Islam, M N; Mollah, A H; Hoque, M A; Hossain, M A; Begum, Z; Islam, M T

    2010-07-01

    Kala-azar is one of the major public health problem in Bangladesh. But the diagnosis of the problem often is difficult, unusual and time consuming, a simple, noninvasive, easy to perform, reliable and rapid diagnostic test has been a long-felt need of the clinicians. Therefore, the present study was conducted to see the sensitivity and specificity of Latex Agglutination test (KAtex) to detect leishmanial antigen from urine of kala-azar cases. The study was carried out in the department of Paediatrics, Mymensingh Medical College and Hospital, Bangladesh during July to December, 2008. A total of 100 urine samples were collected of which 50 were confirmed kala-azar cases and 50 were age and sex matched controls. Out of 50 kala-azar cases 47 showed positive result of KAtex. The test was also positive in 01 out of 30 healthy controls. None of the febrile controls was positive by KAtex. The sensitivity, specificity, positive predictive value and negative predictive value of the test using presence of LD bodies in splenic and/or bone marrow aspirate as gold standard were 94%, 98%, 97.91% and 94.23% respectively. KAtex is simple, noninvasive, easy to perform, rapid and reliable test for diagnosing kala-azar in endemic area and useful for small, less equipped laboratories as well as for the laboratories with better facilities.

  8. Two-Phase Microfluidic Systems for High Throughput Quantification of Agglutination Assays

    KAUST Repository

    Castro, David

    2018-04-01

    agglutination assay, and turn it into a quantitative High Sensitivity-CRP test, with a lower detection limit of 0.5 mg/L using light scattering. Agglutination assays are an incredibly versatile tool, capable of detecting an ever-growing catalog of infectious diseases, proteins and metabolites. A system such as that presented in this thesis is a step towards being able to produce high throughput microfluidic solutions with widespread adoption.

  9. Comparison of agglutinating and neutralizing antibodies to serovar hardjo in sows immunized with two commercial whole culture polivalent anti-leptospira bacterins

    Science.gov (United States)

    Soto, Francisco Rafael Martins; Pinheiro, Sônia Regina; Morais, Zenaide Maria; Gonçales, Amane Paldês; de Azevedo, Sérgio Santos; Bernardi, Fernanda; Camargo, Sebastião Rodrigues; Vasconcellos, Silvio Arruda

    2008-01-01

    It was performed the comparison of the intensity and duration of agglutinating and neutralizing antibodies to serovar Hardjo in swines vaccinated with two commercial anti-leptospira bacterins. Sows no reactive to 24 Leptospira sp serovars in the microscopic agglutination test (MAT) were divided in three groups: Group A (n=08): received two vaccine A doses with 30 days interval, Group B (n=08) two vaccine B doses with 30 days interval and Group C (n=08): control no vaccinated against leptospirosis.Blood samples were collected each 30 days during six months following the first vaccination. The sera were tested by MAT and growth inhibition test (GIT) to serovar Hardjo in order to evaluate respectively agglutinating and neutralizing antibodies. It was found that neutralizing antibodies persisted for a longer time than the agglutinating ones and that the absence of agglutinating antibodies does not means in the absence of the neutralizing. The peaks of agglutinating antibodies was obtained at least 30 days earlier than that produced by neutralizing. The duration of both kinds of antibodies measured differed between the two bacterines tested. The period for inducing neutralizing antibodies against serovar Hardjo indicated that gilts must be immunized with two doses of whole culture anti-leptospira bacterines applied 30 days each other at least 90 days before the first mating. For the maintenance of hight levels of neutralizing antibodies the revaccinations must be performed every six months after the first vaccination. PMID:24031250

  10. Rapid detection of methicillin resistance in coagulase-negative staphylococci by a penicillin-binding protein 2a-specific latex agglutination test.

    Science.gov (United States)

    Horstkotte, M A; Knobloch, J K; Rohde, H; Mack, D

    2001-10-01

    The detection of PBP 2a by the MRSA-Screen latex agglutination test with 201 clinical coagulase-negative staphylococci had an initial sensitivity of 98% and a high degree of specificity for Staphylococcus epidermidis strains compared to PCR for mecA. Determination of oxacillin MICs evaluated according to the new breakpoint (0.5 microg/ml) of the National Committee for Clinical Laboratory Standards exhibited an extremely low specificity for this population.

  11. Aglutininas anti-Brucella abortus no soro e em secreção de bursite cervical em eqüinos

    Directory of Open Access Journals (Sweden)

    Ribeiro M.G.

    2003-01-01

    Full Text Available Fistulous wither secretions from three horses were tested by the plate agglutination (PAT, tube agglutination (SAT, buffered plate-Rose Bengal (RBPT and 2-mercaptoethanol (2-ME tests, comparatively with standard agglutination tests. In the modified tests, titers were increased in the PAT, SAT and 2-ME tests and positive reaction was observed in RBPT. Brucella abortus was isolated from the secretion of fistulous withers collected from one animal. These results suggest that the modified tests may be used as alternative tests to diagnose brucellosis in horses with fistulous withers.

  12. Ultrasonic Testing of NIF Amplifier FAU Top Plates

    International Nuclear Information System (INIS)

    Chinn, D.J.; Huber, R.D.; Haskins, J.J.; Rodriguez, J.A.; Souza, P.R.; Le, T.V.

    2002-01-01

    A key component in the National Ignition Facility (NIF) laser optic system is the amplifier frame assembly unit (FAU). The cast aluminum top plate that supports the FAU is required to withstand loads that would occur during an earthquake with a recurrence period of 1000 years. The stringent seismic requirements placed on the FAU top plate induced a study of the cast aluminum material used in the top plate. Ultrasonic testing was used to aid in characterizing the aluminum material used in the plates. This report documents the work performed using contact ultrasonic testing to characterize the FAU top plate material. The ultrasonic work reported here had 3 objectives: (1) inspect the plate material before cyclic testing conducted at the Pacific Earthquake Engineering Research Center (PEER); (2) determine the overall quality of individual plates; and (3) detect large defects in critical areas of individual plates. Section III, ''Pre-cyclic test inspection'', describes work performed in support of Objective 1. Section IV, ''Ultrasonic field measurements'', describes work performed in support of Objectives 2 and 3

  13. Surgical management of vulvovaginal agglutination due to lichen planus.

    Science.gov (United States)

    Fairchild, Pamela S; Haefner, Hope K

    2016-02-01

    Lichen planus is a rare dermatological disorder that is often associated with painful and disfiguring vulvovaginal effects. At the University of Michigan Center for Vulvar Diseases, we see many women with vulvovaginal lichen planus each year, with marked scarring and vulvovaginal agglutination that precludes vaginal intercourse and causes difficulty with urination. Through our experience, we developed a protocol for the operative management and postoperative care for severe vulvovaginal agglutination. Our objective is to share this protocol with a wider audience so that providers who see patients with these devastating effects of lichen planus can benefit from our experience to better serve this patient population. The figure represents a case of erosive lichen planus with early vaginal agglutination. The video reviews the pathophysiology and presentation of lichen planus. We then present a case of scarring and agglutination in a young woman, including our surgical management and postoperative care recommendations. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Comparative determination of the rheumatic factor by means of agglutination, immunofluorescence and radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Jaeger, L.; Storz, H.; Hein, G.; Schlenvoigt, G. (Friedrich-Schiller-Universitaet, Jena (German Democratic Republic). Bereich Medizin)

    1982-01-01

    The rheumatic factor (RF) was determined by means of agglutination, immunofluorescence (IF) test and radioimmunoassay (RIPEGA) in random groups of 56 patients with rheumatoid arthritis (RA), 13 patients with seronegative RA and 39 patients with psoriasis arthropathica. All three methods are of equal value with regard to the number of positive results. Further classification of seronegative patients, i.e. patients with a negative agglutination reaction and the clinical symptoms of RA is possible with the IF method and, above all, by means of RIPEGA. But because of the comprehensive test devices the two methods are only an alternative. Titer differences are attributed to the different indication principles and the immunological heterogeneity of RF. An improvement of the diagnosis of activity was not possible.

  15. Comparative determination of the rheumatic factor by means of agglutination, immunofluorescence and radioimmunoassay

    International Nuclear Information System (INIS)

    Jaeger, L.; Storz, H.; Hein, G.; Schlenvoigt, G.

    1982-01-01

    The rheumatic factor (RF) was determined by means of agglutination, immunofluorescence (IF) test and radioimmunoassay (RIPEGA) in random groups of 56 patients with rheumatoid arthritis (RA), 13 patients with seronegative RA and 39 patients with psoriasis arthropathica. All three methods are of equal value with regard to the number of positive results. Further classification of seronegative patients, i.e. patients with a negative agglutination reaction and the clinical symptoms of RA is possible with the IF method and, above all, by means of RIPEGA. But because of the comprehensive test devices the two methods are only an alternative. Titer differences are attributed to the different indication principles and the immunological heterogeneity of RF. An improvement of the diagnosis of activity was not possible. (author)

  16. Operational test of bonded magnetocaloric plates

    DEFF Research Database (Denmark)

    Bahl, Christian; Navickaité, Kristina; Neves Bez, Henrique

    2017-01-01

    Bonded plates made by hot pressing La0.85Ce0.15Fe11.25Mn0.25Si1.5Hy particles and resin have been tested as active magnetic regenerators in a small scale magnetocaloric device. Firstly the plates were carefully characterised magnetically and thermally. The plates were prepared with 5 wt% resin...

  17. Rapid Detection of Methicillin Resistance in Coagulase-Negative Staphylococci by a Penicillin-Binding Protein 2a-Specific Latex Agglutination Test

    OpenAIRE

    Horstkotte, Matthias A.; Knobloch, Johannes K.-M.; Rohde, Holger; Mack, Dietrich

    2001-01-01

    The detection of PBP 2a by the MRSA-Screen latex agglutination test with 201 clinical coagulase-negative staphylococci had an initial sensitivity of 98% and a high degree of specificity for Staphylococcus epidermidis strains compared to PCR for mecA. Determination of oxacillin MICs evaluated according to the new breakpoint (0.5 μg/ml) of the National Committee for Clinical Laboratory Standards exhibited an extremely low specificity for this population.

  18. 46 CFR 57.06-2 - Production test plate interval of testing.

    Science.gov (United States)

    2010-10-01

    ... WELDING AND BRAZING Production Tests § 57.06-2 Production test plate interval of testing. (a) At least one... 46 Shipping 2 2010-10-01 2010-10-01 false Production test plate interval of testing. 57.06-2... follows: (1) When the extent of welding on a single vessel exceeds 50 lineal feet of either or both...

  19. Reactivity of various leishmanial antigens in a direct agglutination test and their value in differentiating post-kala azar dermal leishmaniasis from leprosy and other skin conditions

    NARCIS (Netherlands)

    El Harith, A.; Chowdhury, S.; Al-Masum, A.; Semião-Santos, S.; Das, P. K.; Akhter, S.; Vetter, J. C.; Haq, I.

    1996-01-01

    A direct agglutination test (DAT) for the detection of post-kala azar dermal leishmaniasis (PKDL) was evaluated in conditions that simulate the disease clinically or immunologically. A reference strain of Leishmania donovani (LEM 1399), and antigen preparations from Leishmania isolates from

  20. Brucella sero-prevalence and modifiable risk factors among ...

    African Journals Online (AJOL)

    resources and Biosecurity, Makerere University, P.O. Box 7062, Kampala, Uganda ... Sera samples were tested using Rapid Plate Agglutination Test, Standard Tube Agglutination Test ... their laboratory identification numbers for purposes of.

  1. Evolution of Shock Melt Compositions in Lunar Agglutinates

    Science.gov (United States)

    Vance, A. M.; Christoffersen, R.; Keller, L. P.

    2015-01-01

    Lunar agglutinates are aggregates of regolith grains fused together in a glassy matrix of shock melt produced during smaller-scale (mostly micrometeorite) impacts. Agglutinate formation is a key space weathering process under which the optically-active component of nanophase metallic Fe (npFe(sup 0)) is added to the lunar regolith. Here we have used energy-dispersive X-ray (EDX) compositional spectrum imaging in the SEM to quantify the chemical homogeneity of agglutinitic glass, correlate its homogeneity to its parent soil maturity, and identify the principle chemical components contributing to the shock melt compositional variations.

  2. Determination of degree of RBC agglutination for blood typing using a small quantity of blood sample in a microfluidic system.

    Science.gov (United States)

    Chang, Yaw-Jen; Ho, Ching-Yuan; Zhou, Xin-Miao; Yen, Hsiu-Rong

    2018-04-15

    Blood typing assay is a critical test to ensure the serological compatibility of a donor and an intended recipient prior to a blood transfusion. This paper presents a microfluidic blood typing system using a small quantity of blood sample to determine the degree of agglutination of red blood cell (RBC). Two measuring methods were proposed: impedimetric measurement and electroanalytical measurement. The charge transfer resistance in the impedimetric measurement and the power parameter in the electroanalytical measurement were used for the analysis of agglutination level. From the experimental results, both measuring methods provide quantitative results, and the parameters are linearly and monotonically related to the degree of RBC agglutination. However, the electroanalytical measurement is more reliable than the impedimetric technique because the impedimetric measurement may suffer from many influencing factors, such as chip conditions. Five levels from non-agglutination (level 0) to strong agglutination (level 4+) can be discriminated in this study, conforming to the clinical requirement to prevent any risks in transfusion. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Calibration and use of filter test facility orifice plates

    Science.gov (United States)

    Fain, D. E.; Selby, T. W.

    1984-07-01

    There are three official DOE filter test facilities. These test facilities are used by the DOE, and others, to test nuclear grade HEPA filters to provide Quality Assurance that the filters meet the required specifications. The filters are tested for both filter efficiency and pressure drop. In the test equipment, standard orifice plates are used to set the specified flow rates for the tests. There has existed a need to calibrate the orifice plates from the three facilities with a common calibration source to assure that the facilities have comparable tests. A project has been undertaken to calibrate these orifice plates. In addition to reporting the results of the calibrations of the orifice plates, the means for using the calibration results will be discussed. A comparison of the orifice discharge coefficients for the orifice plates used at the seven facilities will be given. The pros and cons for the use of mass flow or volume flow rates for testing will be discussed. It is recommended that volume flow rates be used as a more practical and comparable means of testing filters. The rationale for this recommendation will be discussed.

  4. Statistical test for the distribution of galaxies on plates

    International Nuclear Information System (INIS)

    Garcia Lambas, D.

    1985-01-01

    A statistical test for the distribution of galaxies on plates is presented. We apply the test to synthetic astronomical plates obtained by means of numerical simulation (Garcia Lambas and Sersic 1983) with three different models for the 3-dimensional distribution, comparison with an observational plate, suggest the presence of filamentary structure. (author)

  5. Imaging based agglutination measurement of magnetic micro-particles on a lab-on-a-disk platform

    DEFF Research Database (Denmark)

    Wantiya, P.; Burger, Robert; Alstrøm, Tommy Sonne

    2014-01-01

    In this work we present a magnetic micro beads based agglutination assay on a centrifugal microfluidic platform. An imaging based method is used to quantify bead agglutination and measure the concentration of antibodies or C-reactive protein in solution.......In this work we present a magnetic micro beads based agglutination assay on a centrifugal microfluidic platform. An imaging based method is used to quantify bead agglutination and measure the concentration of antibodies or C-reactive protein in solution....

  6. Evaluation of an Immunocapture-Agglutination Test (Brucellacapt) for Serodiagnosis of Human Brucellosis

    Science.gov (United States)

    Orduña, Antonio; Almaraz, Ana; Prado, Ana; Gutierrez, M. Purificación; Garcia-Pascual, Agustina; Dueñas, Ana; Cuervo, Milagros; Abad, Ramon; Hernández, Beatriz; Lorenzo, Belen; Bratos, Miguel A.; Torres, Antonio Rodriguez

    2000-01-01

    We evaluated the validity and the usefulness of a new test for the diagnosis of human brucellosis based on an immunocapture-agglutination technique. A total of 315 sera from 82 patients with a diagnosis of brucellosis, 157 sera from patients in whom brucellosis was suspected but not confirmed, and 412 sera from people living in rural areas with endemic brucellosis were studied. The seroagglutination test (SAT), Coombs anti-Brucella test, and Brucellacapt test were evaluated. All the initial sera from the 82 patients proved to be positive in Brucellacapt and Coombs tests, while only 75 (91.4%) were positive in the SAT. If a ≥1/160 diagnostic threshold titer was defined for the Brucellacapt test, Coombs test, and SAT, the sensitivities were 95.1, 91.5, and 65.8%, respectively. Taking the same diagnostic threshold titer for the 157 sera from the unconfirmed but suspected patients, the specificities of the Brucellacapt, Coombs, and SAT were 81.5, 96.2, and 100%, respectively; for the 412 control sera, the specificities were 99.0, 99.8, and 100%. The diagnostic efficiency (area below the receiver operating characteristic curve) of Brucellacapt was 0.987852 (95% confidence interval [CI], 0.95109 to 0.99286), very similar to the diagnostic efficiency of the Coombs test (0.97611; 95% CI, 0.94781 to 0.99146) and higher than that of SAT (0.91013; 95% CI, 0.86649 to 0.94317). The results of the Brucellacapt test were compared with those of the Coombs test (correlation coefficient, 0.956; P = 0.000) and SAT (correlation coefficient, 0.866; P = 0.000). The study shows very good correlation between the Brucellacapt and Coombs tests, with a high concordance between titers obtained in the two tests. Nevertheless, lower correlation and concordance were found between the Brucellacapt and Coombs tests when the results for titers of ≥1/160 were compared (0.692; P = 0.000). In acute brucellosis, the Brucellacapt and Coombs tests render positive titers of ≥1/160. When the titers

  7. R and G color component competition of RGB image decomposition as a criterion to register RBC agglutinates for blood group typing.

    Science.gov (United States)

    Doubrovski, Valeri A; Ganilova, Yuliya A; Zabenkov, Igor V

    2014-03-01

    A new approach of the criterion assignment for registration of erythrocyte agglutinates to instrumentally determine blood group type is suggested. The criterion is based on comparison of R and G components of RGB decomposition of microscopy digital image taken for the blood-serum mixture sample. For the chosen experimental conditions, the minimal size (area) of RBC agglutinate to be registered by the criterion suggested is estimated theoretically. The proposed method was tested experimentally on the example of monitoring agglutinates in flow. The encouraging experimental results were obtained for improvement of the resolving power of the method; the optimal experimental conditions were revealed for maximum resolution. Though the suggested method was realized for dynamic (flow) blood group determination, it could also be applied for diagnostics in a stationary environment. This approach increases the reliability of RBC agglutinates registration and, hence, blood group typing. The results may be used to develop the apparatus for automated determination of human blood group.

  8. Evaluation of chromogenic medium and direct latex agglutination test for detection of group B streptococcus in vaginal specimens from pregnant women in Lebanon and Kuwait.

    Science.gov (United States)

    Ghaddar, Nahed; Alfouzan, Wadha; Anastasiadis, Elie; Al Jiser, Tamima; Itani, Saad Eddine; Dernaika, Racha; Eid, Toufic; Ghaddar, Ali; Charafeddine, Adib; Dhar, Rita; El Hajj, Hiba

    2014-10-01

    This study was undertaken to evaluate chromogenic medium and a direct latex agglutination test (DLA) for detection of Group B Streptococcus (GBS) in the vaginal specimens of pregnant women, and to ascertain the prevalence of GBS in this population in Kuwait and Lebanon. Vaginal swabs, collected from women at 35-37 weeks of gestation, were cultured on 5 % sheep blood agar (SBA), colistin nalidixic acid agar (CNA), Strept B Select chromogenic agar (SBS) as well as Lim enrichment broth in 168 cases in Lebanon while only SBA was used for 1391 samples in Kuwait. In addition, vaginal samples from 102 GBS-positive and 20 GBS-negative women near the time of delivery were collected in Kuwait for evaluation of the DLA test. During the study period, the prevalence of GBS colonization was determined to be 20.7 % (288/1391) in Kuwait while 18.4 % (31) of 168 pregnant women in Lebanon had vaginal cultures positive for GBS. By direct plating of vaginal swabs on the three media used, the isolation rates of GBS were 51.6, 64.5 and 77.4 % on SBA, CNA and SBS, respectively, which increased to 90.35, 93.1 and 96.8 %, respectively, following subculture in Lim broth after 18 h of incubation. The sensitivity of the DLA test was found to be dependent on the density of GBS colonization, resulting in 100 % sensitivity and 100 % specificity for heavy (>10(2) c.f.u. per swab) and moderately heavy (50-100 c.f.u. per swab) growth of GBS. However, for vaginal specimens yielding women. The DLA test, in particular, could prove to be a useful tool for immediate detection of GBS in women near delivery so that intrapartum antibiotic prophylaxis can be initiated. © 2014 The Authors.

  9. Fuel performance analysis for the HAMP-1 mini plate test

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Byoung Jin; Tahka, Y. W.; Yim, J. S.; Lee, B. H. [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    U-7wt%Mo/Al- 5wt%Si dispersion fuel with 8gU/cm{sup 3} is chosen to achieve more efficiency and higher performance than the conventional U{sub 3}Si{sub 2} fuel. As part of the fuel qualification program for the KiJang research reactor (KJRR), three irradiation tests with mini-plates are on the way at the High-flux Advanced Neutron Application Reactor (HANARO). The first test among three HANARO Mini-Plate Irradiation tests (HAMP-1, 2, 3) has completed. PLATE code has been initially developed to analyze the thermal performance of high density U-Mo/Al dispersion fuel plates during irradiation [1]. We upgraded the PLATE code with the latest irradiation results which were implemented by corrosion, thermal conductivity and swelling model. Fuel performance analysis for HAMP-1 was conducted with updated PLATE. This paper presents results of performance evaluation of the HAMP-1. Maximum fuel temperature was obtained 136 .deg., which is far below the preset limit of 200 .deg. for the irradiation test. The meat swelling and corrosion thickness was also confirmed that the developed fuel would behave as anticipated.

  10. Diagnostic Efficacy of Modified Coagglutination Test in the Diagnosis of Human Brucellosis

    Directory of Open Access Journals (Sweden)

    Mohite S.T

    2013-07-01

    Full Text Available Background: Laboratory help is must for thediagnosis of human brucellosis due to proteanclinical manifestations. As culture is hazardous,time consuming and less sensitive, serologicaltests are preferred for the diagnosis. Aggluti-nation tests like Rose Bengal PlateTest (RBPT, Serum Agglutination tests (SAT,2-Mercaptoethanol test (2-ME that are com-monly employed for the diagnosis either lacksensitivity or specificity. Coombs test andBrucellacapt though are sensitive and specific,workout costly. Therefore, modifiedcoagglutination test was developed and its di-agnostic efficacy was evaluated. Aims and Ob-jectives: To develop modified coagglutinationtest for the diagnosis of human brucellosis andcompare it with Coombs test. Materials andMethods: Serum samples collected from 191brucellosis patients and 100 controls were sub-jected to 2-ME, Coombs test and modifiedcoagglutination test (MCOAG. Blood culturewas performed by Castaneda’s method in all thepatients. Results: Significant difference in thepositivity rate was seen between MCOAG and2-ME. The results of MCOAG were compa-rable with Coombs test. Conclusions: Modi-fied coagglutination test is a better option toCoombs test for the serodiagnosis of brucel-losis in resource constrained countries as it issensitive, specific and cost effective.

  11. Modification of the Rappaport rapid test in large-scale testing for syphilis. Evaluation of the rapid plate and rapid card tests.

    Science.gov (United States)

    Ghinsberg, R; Meir, E; Blumstein, G; Kafeman, R

    1975-11-01

    The Rappaport rapid (RR) plate and card tests were developed as modifications of the RR tube test to permit rapid and inexpensive screening of large numbers of subjects for the diagnosis of syphilis. More than 2,000 sera were examined in parallel by the Venereal Disease Research Laboratory (VDRL) slide test, the rapid plasma reagin (RPR) card test and the RR plate and card tests. There was complete agreement between the RR plate and card tests and the VDRL slide and RPR card tests in 96.6% of sera. In a selected group of 1,530 sera examined, in addition, by the fluorescent treponemal antibody absorption (FTA-ABS) test, there was agreement between the RR plate and card tests and the FTA-ABS test in 74.3% of sera and between the VDRL and RPR tests and the FTA-ABS test in 73.7% of sera. The RR plate test was found to be sufficiently sensitive and specific for the diagnosis of syphilis, although the VDRL slide test is perhaps more sensitive in primary and late latent syphilis. Since the antigen used in the RR tests is colored and stable and the sera do not require inactivation before the test, the tests are easier to perform than the VDRL slide test: the RR plate and card tests could therefore replace the VDRL test as a screening test, with hardly any loss of accuracy.

  12. Are the Major Agglutinative Languages Genetically Related?

    Science.gov (United States)

    Hakola, H. P. A.

    1989-01-01

    Examination of accidental CVC and CV correspondences among languages representing 5 large families of agglutinative languages found that comparison pairs had much more similarity between basic 100-word vocabularies than would have been possible by mere chance, supporting the hypothesis that those 5 language families were mutually related.…

  13. Isolation, in vitro culture, ultrastructure study, and characterization by lectin-agglutination tests of Phytomonas isolated from tomatoes (Lycopersicon esculentum) and cherimoyas (Anona cherimolia) in southeastern Spain.

    Science.gov (United States)

    Sanchez-Moreno, M; Fernandez-Becerra, C; Mascaro, C; Rosales, M J; Dollet, M; Osuna, A

    1995-01-01

    Plants of Lycopersicon esculentum (grown in greenhouses) and Anona cherimolia cultivated in southeastern Spain were examined for the presence of trypanosomatid flagellates. Kinetoplastid protozoa were found in the fruits but not in the phloem or other plant tissues. Parasites were detected from the onset of fruiting. Isolates were detected from the onset of fruiting. Isolates were adapted to in vitro culturing in monophase media. The form and the structural organization was studied by scanning and transmission electron microscopy. The parasites showed an ultrastructural pattern similar to that of other species of the genus Phytomonas. In tomatoes experimentally inoculated with flagellates cultivated in vitro, we observed that the parasites did not lose their infectious capacity. Three strains of trypanosomatids of the genus Phytomonas, isolated from different species of Euphorbia (E. characias and E. hyssopifolia) and from Cocos nucifera, were compared with our isolates by lectin-agglutination tests. Our isolates were different from the two strains isolated from Euphorbia, but with this technique we could not differentiate our isolates from those of the coconut, nor could we differentiate between the isolates, their ultrastructural similarity together with their similar behavior in the lectin-agglutination test suggesting that these isolates have a common origin.

  14. Sero-prevalence of brucellosis among blood donors in Ahvaz, Southwest Iran

    Directory of Open Access Journals (Sweden)

    Abdolhussein Shakurnia

    2014-02-01

    Full Text Available Objective: To identify sero-prevalence of brucellosis among blood donors in Ahvaz city, Southwest Iran. Methods: A total number of 1 450 serum samples from blood donation were collected and were screened for the presence of brucella antibody. Rose Bengal Plate Test, Standard Agglutination Test (SAT, and 2-mercaptoethanol (2ME agglutination were tested in the sample. SAT dilution ≥1/80 and 2ME agglutination ≥1/40 were considered positive. Results: Sero-prevalence of brucellosis among the blood donors was 0.70%, 0.34%, and 0.20% by Rose Bengal Plate Test, SAT, and 2ME respectively. Conclusions: Considering the 1/80 titer of SAT as the criteria of contamination with brucella, routine screening of sero-prevalence of brucella in blood donors is not recommended in this area.

  15. Evaluation of plate type fuel elements by eddy current test method

    International Nuclear Information System (INIS)

    Frade, Rangel Teixeira

    2015-01-01

    Plate type fuel elements are used in MTR research nuclear reactors. The fuel plates are manufactured by assembling a briquette containing the fissile material inserted in a frame, with metal plates in both sides of the set, to act as a cladding. This set is rolled under controlled conditions in order to obtain the fuel plate. In Brazil, this type of fuel is manufactured by IPEN and used in the IEA-R1 reactor. After fabrication of three batches of fuel plates, 24 plates, one of them is taken, in order to verify the thickness of the cladding. For this purpose, the plate is sectioned and the thickness measurements are carried out by using optical microscopy. This procedure implies in damage of the plate, with the consequent cost. Besides, the process of sample preparation for optical microscopy analysis is time consuming, it is necessary an infrastructure for handling radioactive materials and there is a generation of radioactive residues during the process. The objective of this study was verify the applicability of eddy current test method for nondestructive measurement of cladding thickness in plate type nuclear fuels, enabling the inspection of all manufactured fuel plates. For this purpose, reference standards, representative of the cladding of the fuel plates, were manufactured using thermomechanical processing conditions similar to those used for plates manufacturing. Due to no availability of fuel plates for performing the experiments, the presence of the plate’s core was simulated using materials with different electrical conductivities, fixed to the thickness reference standards. Probes of eddy current testing were designed and manufactured. They showed high sensitivity to thickness variations, being able to separate small thickness changes. The sensitivity was higher in tests performed on the reference standards and samples without the presence of the materials simulating the core. For examination of the cladding with influence of materials simulating the

  16. Infecção em cão por Brucella abortus: relato de caso Brucella abortus infection in dog: case report

    Directory of Open Access Journals (Sweden)

    J. Megid

    2007-12-01

    Full Text Available Brucella abortus infection is reported in a dog from a rural area that presented at clinical evaluation left testicular enlargement and right testicular decrease. Serum resulted negative to rapid agglutination test and agar gel immunodifusion with Brucella ovis antigen but positive to buffered plate agglutination test, tube agglutination test and 2- Mercapthoetanol with B. abortus antigen. Brucella isolation was negative in blood, testicular material, semen and urine. Brucella DNA was detected in PCR from urine and blood.

  17. Effect of nickel plating upon tensile tests of uranium--0.75 titanium alloy

    International Nuclear Information System (INIS)

    Hemperly, V.C.

    1975-01-01

    Electrolytic-nickel-plated specimens of uranium-0.75 wt percent titanium alloy were tested in air at 20 and 100 percent relative humidities. Tensile-test ductility values were lowered by a high humidity and also by nickel plating alone. Baking the nickel-plated specimens did not eliminate the ductility degradation. Embrittlement because of nickel plating was also evident in tensile tests at -34 0 C. (U.S.)

  18. General-Purpose Heat Source Safety Verification Test program: Edge-on flyer plate tests

    International Nuclear Information System (INIS)

    George, T.G.

    1987-03-01

    The radioisotope thermoelectric generator (RTG) that will supply power for the Galileo and Ulysses space missions contains 18 General-Purpose Heat Source (GPHS) modules. The GPHS modules provide power by transmitting the heat of 238 Pu α-decay to an array of thermoelectric elements. Each module contains four 238 PuO 2 -fueled clads and generates 250 W(t). Because the possibility of a launch vehicle explosion always exists, and because such an explosion could generate a field of high-energy fragments, the fueled clads within each GPHS module must survive fragment impact. The edge-on flyer plate tests were included in the Safety Verification Test series to provide information on the module/clad response to the impact of high-energy plate fragments. The test results indicate that the edge-on impact of a 3.2-mm-thick, aluminum-alloy (2219-T87) plate traveling at 915 m/s causes the complete release of fuel from capsules contained within a bare GPHS module, and that the threshold velocity sufficient to cause the breach of a bare, simulant-fueled clad impacted by a 3.5-mm-thick, aluminum-alloy (5052-T0) plate is approximately 140 m/s

  19. Characterization and testing of monolithic RERTR fuel plates

    Energy Technology Data Exchange (ETDEWEB)

    Keiser, D.D.; Jue, J.F.; Burkes, D.E. [Idaho National Lab., Idaho Falls, ID (United States)

    2007-07-01

    Monolithic fuel plates are being developed as a LEU (low enrichment uranium) fuel for application in research reactors throughout the world. These fuel plates are comprised of a U-Mo alloy foil encased in aluminum alloy cladding. Three different fabrication techniques have been looked at for producing monolithic fuel plates: hot isostatic pressing (HIP), transient liquid phase bonding (TLPB), and friction stir welding (FSW). Of these three techniques, HIP and FSW are currently being emphasized. As part of the development of these fabrication techniques, fuel plates are characterized and tested to determine properties like hardness and the bond strength at the interface between the fuel and cladding. Testing of HIP-made samples indicates that the foil/cladding interaction behavior depends on the Mo content in the UMo foil, the measured hardness values are quite different for the fuel, cladding, and interaction zone phase and Ti, Zr and Nb are the most effective diffusion barriers. For FSW samples, there is a dependence of the bond strength at the foil/cladding interface on the type of tool that is employed for performing the actual FSW process. (authors)

  20. Document Categorization with Modified Statistical Language Models for Agglutinative Languages

    Directory of Open Access Journals (Sweden)

    Tantug

    2010-11-01

    Full Text Available In this paper, we investigate the document categorization task with statistical language models. Our study mainly focuses on categorization of documents in agglutinative languages. Due to the productive morphology of agglutinative languages, the number of word forms encountered in naturally occurring text is very large. From the language modeling perspective, a large vocabulary results in serious data sparseness problems. In order to cope with this drawback, previous studies in various application areas suggest modified language models based on different morphological units. It is reported that performance improvements can be achieved with these modified language models. In our document categorization experiments, we use standard word form based language models as well as other modified language models based on root words, root words and part-of-speech information, truncated word forms and character sequences. Additionally, to find an optimum parameter set, multiple tests are carried out with different language model orders and smoothing methods. Similar to previous studies on other tasks, our experimental results on categorization of Turkish documents reveal that applying linguistic preprocessing steps for language modeling provides improvements over standard language models to some extent. However, it is also observed that similar level of performance improvements can also be acquired by simpler character level or truncated word form models which are language independent.

  1. Radiation-induced alterations in binding of concanavalin A to cells and in their susceptibility to agglutination

    International Nuclear Information System (INIS)

    Takahashi, Kazuhide; Kaneko, Ichiro

    1986-01-01

    Cell susceptibility to agglutination mediated by a plant lectin, concanavalin A (Con A), and the binding capacity of Con A to cells following γ-irradiation have been examined in mouse myeloid leukaemia cells cultured in suspension. Irradiation caused an immediate decrease in the amount of Con A bound to the cell surface, whereas susceptibility of irradiated cells to agglutination by Con A was unchanged when compared to that of the unirradiated cells. Post-irradiation incubation of cells at 37 0 resulted in a temporary, more than 1.3-fold increase in cell susceptibility to agglutination 60 min after irradiation, whereas binding capacity of cells for Con A gradually-recovered following irradiation, reaching a comparable level to that of unirradiated cells 3 h after irradiation. Cell susceptibility to agglutination by Con A does not depend strongly on its binding capacity. (author)

  2. Comparison of a New and Rapid Method: Brucella Coombs Gel Test With Other Diagnostic Tests.

    Science.gov (United States)

    Kalem, Fatma; Ergün, Ayşe Gül; Durmaz, Süleyman; Doğan, Metin; Ertuğrul, Ömür; Gündem, Seval

    2016-09-01

    The aim of this study was to detect reliability of Brucella Coombs gel test (BCGT) by comparing with with ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination methods in serological diagnosis of brucellosis. Brucella Coombs gel test (BCGT), Brucella ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination tests of 78 patients with presumptive diagnosis of brucellosis which were sent to Microbiology Laboratory of Konya Numune Hospital from various regions of Konya were studied. Of 78 patients with ELISA IgG and IgM, STA, BICA and BCGT; 26, 21, 10, 12 and 12 were positive. When compared with BICA, the sensitivity and specifity of BCGT were 100% and 100%, respectively. According to results BCGT can be used as a diagnostic test in routine laboratories after more comprehensive studies in control groups and patients. © 2016 Wiley Periodicals, Inc.

  3. Irradiation testing of miniature fuel plates for the RERTR program

    Energy Technology Data Exchange (ETDEWEB)

    Senn, R L; Martin, M M [Oak Ridge National Laboratory, Oak Ridge, TN 37830 (United States)

    1983-08-01

    An irradiation test facility, which provides a test bed for irradiating a variety of miniature fuel plates miniplates) for the Reduced Enrichment Research and Test Reactors (RERTR) program, has been placed into operation. The objective of these tests is to screen various candidate fuel materials as to their suitability for replacing the highly enriched uranium fuel materials currently used by the world's test and research reactors with a lower enrichment fuel material, without significantly degrading reactor operating characteristics and power levels. The use of low uranium enrichment of about 20% {sup 235}U in place of highly enriched fuel for these reactors would reduce the potential for {sup 235}U diversion. Fuel materials currently being evaluated in this first phase of these screening tests include aluminum-base dispersion-type fuel plates with fuel cores of 1) high uranium content U{sup 3}){sup 8}-Al being developed by ORNL, 2) high uranium content UAI{sub x}-Al being developed by EG and G Idaho, Inc., and 3) very high uranium content U{sub 3}Si-Al- being developed by ANL. The miniplates are 115-mm long by 50-mm wide with overall plate thicknesses of 1.27 or 1.52 mm. The fuel core dimensions vary according to overall plate thicknesses with a minimal clad thickness requirement of 0.20 mm. Sixty such miniplates (thirty of each thickness) can be irradiated in one test facility. The irradiation test facility, designated as HFED-1 is operating in core position E-7 in the Oak Ridge Research Reactor (ORR), a 30-MW water-moderated reactor. The peak neutron flux measured for this experiment is 1.96 x 10{sup 18} neutrons m{sub -2} s{sub -1}. The various types of miniplates will achieve burnups of up to approximately 2.2x10{sup 27} fissions/m{sup 3} of fuel, which will require approximately eight full power months of irradiation. During reactor shutdown periods, the experiment is removed from the reactor, moved to a special poolside station, disassembled, and inspected

  4. Tensile Test of Welding Joint Parts for a Plate-type Fuel Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, K. H.; Kim, J. Y.; Kim, H. J.; Yim, J. S. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    The tensile tests were performed using an INSTRON 4505 (universal tensile) testing machine. These welding joints are composed of two parts for the soundness of the fuel assembly; one is the side plate with a fixing bar and the other is a side plate with an end fitting. These two joint parts are fabricated by TIG welding method. The tensile tests of the welding joints of a plate-type FA are executed by a tensile test. The fixture configurations for the specimen are very important to obtain the strict test results. The maximum strength has an approximately linear correlation with the unit bonding length of the welding joints. In spite of these results, the maximum strengths of the welding joints are satisfied according to the minimum requirement. These tensile tests of the joint parts for a plate-type fuel assembly (FA) have to be executed to evaluate the structural strength. For the tensile test, the joint parts of a FA used in the test are made of aluminum alloy (Al6061-T6)

  5. Tensile Test of Welding Joint Parts for a Plate-type Fuel Assembly

    International Nuclear Information System (INIS)

    Yoon, K. H.; Kim, J. Y.; Kim, H. J.; Yim, J. S.

    2013-01-01

    The tensile tests were performed using an INSTRON 4505 (universal tensile) testing machine. These welding joints are composed of two parts for the soundness of the fuel assembly; one is the side plate with a fixing bar and the other is a side plate with an end fitting. These two joint parts are fabricated by TIG welding method. The tensile tests of the welding joints of a plate-type FA are executed by a tensile test. The fixture configurations for the specimen are very important to obtain the strict test results. The maximum strength has an approximately linear correlation with the unit bonding length of the welding joints. In spite of these results, the maximum strengths of the welding joints are satisfied according to the minimum requirement. These tensile tests of the joint parts for a plate-type fuel assembly (FA) have to be executed to evaluate the structural strength. For the tensile test, the joint parts of a FA used in the test are made of aluminum alloy (Al6061-T6)

  6. A deep-sea agglutinated foraminifer tube constructed with planktonic foraminifer shells of a single species

    Science.gov (United States)

    Pearson, Paul N.; Expedition 363 Shipboard Scientific Party, IODP

    2018-01-01

    Agglutinated foraminifera are marine protists that show apparently complex behaviour in constructing their shells, involving selecting suitable sedimentary grains from their environment, manipulating them in three dimensions, and cementing them precisely into position. Here we illustrate a striking and previously undescribed example of complex organisation in fragments of a tube-like foraminifer (questionably assigned to Rhabdammina) from 1466 m water depth on the northwest Australian margin. The tube is constructed from well-cemented siliciclastic grains which form a matrix into which hundreds of planktonic foraminifer shells are regularly spaced in apparently helical bands. These shells are of a single species, Turborotalita clarkei, which has been selected to the exclusion of all other bioclasts. The majority of shells are set horizontally in the matrix with the umbilical side upward. This mode of construction, as is the case with other agglutinated tests, seems to require either an extraordinarily selective trial-and-error process at the site of cementation or an active sensory and decision-making system within the cell.

  7. Qualification testing of flat-plate photovoltaic modules

    Science.gov (United States)

    Hoffman, A. R.; Griffith, J. S.; Ross, R. G., Jr.

    1982-01-01

    The placement of photovoltaic modules in various applications, in climates and locations throughout the world, results in different degrees and combinations of environmental and electrical stress. Early detection of module reliability deficiencies via laboratory testing is necessary for achieving long, satisfactory field service. This overview paper describes qualification testing techniques being used in the US Department of Energy's flat-plate terrestrial photovoltaic development program in terms of their significance, rationale for specified levels and durations, and test results.

  8. Legionella species and serogroups in Malaysian water cooling towers: identification by latex agglutination and PCR-DNA sequencing of isolates.

    Science.gov (United States)

    Yong, Stacey Foong Yee; Goh, Fen-Ning; Ngeow, Yun Fong

    2010-03-01

    In this study, we investigated the distribution of Legionella species in water cooling towers located in different parts of Malaysia to obtain information that may inform public health policies for the prevention of legionellosis. A total of 20 water samples were collected from 11 cooling towers located in three different states in east, west and south Malaysia. The samples were concentrated by filtration and treated with an acid buffer before plating on to BCYE agar. Legionella viable counts in these samples ranged from 100 to 2,000 CFU ml(-1); 28 isolates from the 24 samples were examined by latex agglutination as well as 16S rRNA and rpoB PCR-DNA sequencing. These isolates were identified as Legionella pneumophila serogroup 1 (35.7%), L. pneumophila serogroup 2-14 (39%), L. pneumophila non-groupable (10.7%), L. busanensis, L. gormanii, L. anisa and L. gresilensis. L. pneumophila was clearly the predominant species at all sampling sites. Repeat sampling from the same cooling tower and testing different colonies from the same water sample showed concurrent colonization by different serogroups and different species of Legionella in some of the cooling towers.

  9. A simple system for in-droplet incubation and quantification of agglutination assays

    KAUST Repository

    Castro, David

    2013-10-28

    This work reports on a simple system for quantitative sensing of a target analyte based on agglutination in micro-channels. Functionalized microbeads and analyte with no prior incubation are flowed in droplets (~2μL) through a thin silicone tube filled with mineral oil at a flow rate of 150 μL/min. Hydrodynamic forces alone produce a highly efficient mixing of the beads within the droplet, without the need of complex mixing structures or magnetic actuation. The setup allows rapid observation of agglutination (<2 min), which is quantified using image analysis, and has potential application to high-throughput analysis.

  10. A simple system for in-droplet incubation and quantification of agglutination assays

    KAUST Repository

    Castro, David; Kodzius, Rimantas; Foulds, Ian G.

    2013-01-01

    This work reports on a simple system for quantitative sensing of a target analyte based on agglutination in micro-channels. Functionalized microbeads and analyte with no prior incubation are flowed in droplets (~2μL) through a thin silicone tube filled with mineral oil at a flow rate of 150 μL/min. Hydrodynamic forces alone produce a highly efficient mixing of the beads within the droplet, without the need of complex mixing structures or magnetic actuation. The setup allows rapid observation of agglutination (<2 min), which is quantified using image analysis, and has potential application to high-throughput analysis.

  11. Synthesis for Lunar Simulants: Glass, Agglutinate, Plagioclase, Breccia

    Science.gov (United States)

    Weinstein, Michael; Wilson, Stephen A.; Rickman, Douglas L.; Stoeser, Douglas

    2012-01-01

    The video describes a process for making glass for lunar regolith simulants that was developed from a patented glass-producing technology. Glass composition can be matched to simulant design and specification. Production of glass, pseudo agglutinates, plagioclase, and breccias is demonstrated. The system is capable of producing hundreds of kilograms of high quality glass and simulants per day.

  12. Testing flat plate photovoltaic modules for terrestrial environment

    Science.gov (United States)

    Hoffman, A. R.; Arnett, J. C.; Ross, R. G., Jr.

    1979-01-01

    New qualification tests have been developed for flat plate photovoltaic modules. Temperature cycling, cyclic pressure load, and humidity exposure are especially useful for detecting design and fabrication deficiencies. There is positive correlation between many of the observed field effects, such as power loss, and qualification test induced degradation. The status of research efforts for the development of test methodology for field-related problems is reviewed.

  13. Bioactive extracts of red seaweeds Pterocladiella capillacea and Osmundaria obtusiloba (Floridophyceae: Rhodophyta) with antioxidant and bacterial agglutination potential.

    Science.gov (United States)

    de Alencar, Daniel Barroso; de Carvalho, Fátima Cristiane Teles; Rebouças, Rosa Helena; Dos Santos, Daniel Rodrigues; Dos Santos Pires-Cavalcante, Kelma Maria; de Lima, Rebeca Larangeira; Baracho, Bárbara Mendes; Bezerra, Rayssa Mendes; Viana, Francisco Arnaldo; Dos Fernandes Vieira, Regine Helena Silva; Sampaio, Alexandre Holanda; de Sousa, Oscarina Viana; Saker-Sampaio, Silvana

    2016-04-01

    To evaluate the antioxidant, antibacterial and bacterial cell agglutination activities of the hexane (Hex) and 70% ethanol (70% EtOH) extracts of two species of red seaweeds Pterocladiella capillacea (P. capillacea) and Osmundaria obtusiloba. In vitro antioxidant activity was determined by DPPH radical scavenging assay, ferric-reducing antioxidant power assay, ferrous ion chelating assay, β-carotene bleaching assay and total phenolic content quantification. Antimicrobial activity was tested using the method of disc diffusion on Mueller-Hinton medium. The ability of algal extracts to agglutinate bacterial cells was also tested. The 70% EtOH extract of the two algae showed the highest values of total phenolic content compared to the Hex extract. The results of DPPH for both extracts (Hex, 70% EtOH) of Osmundaria obtusiloba (43.46% and 99.47%) were higher than those of P. capillacea (33.04% and 40.81%) at a concentration of 1000 μg/mL. As for the ferrous ion chelating, there was an opposite behavior, extracts of P. capillacea had a higher activity. The extracts showed a low ferric-reducing antioxidant power, with optical density ranging from 0.054 to 0.180. Antioxidant activities of all extracts evaluated for β-carotene bleaching were above 40%. There was no antibacterial activity against bacterial strains tested. However, the extracts of both species were able to agglutinate bacterial Gram positive cells of Staphylococcus aureus and Gram negative cells of Escherichia coli, multidrug-resistant Salmonella and Vibrio harveyi. This is the first report of the interaction between these algal extracts, rich in natural compounds with antioxidant potential, and Gram positive and Gram negative bacterial cells. Copyright © 2016 Hainan Medical College. Production and hosting by Elsevier B.V. All rights reserved.

  14. Containment liner plate anchors and steel embedments test results

    International Nuclear Information System (INIS)

    Chang-Lo, P.L.; Johnson, T.E.; Pfeifer, B.W.

    1977-01-01

    This paper summarizes test data on shear load and deformation capabilities for liner plate line anchors and structural steel embedments in reinforced and prestressed concrete nuclear containments. Reinforced and prestressed nuclear containments designed and constructed in the United States are lined with a minimum of 0.64 cm steel plate. The liner plates are anchored by the use of either studs or structural members (line anchors) which usually run in the vertical direction. This paper will only address line anchors. Static load versus displacement test data is necessary to assure that the design is adequate for the maximum loads. The test program for the liner anchors had the following major objectives: determine load versus displacement data for a variety of anchors considering structural tees and small beams with different weld configurations, from the preceding tests, determine which anchors would lead to an economical and extremely safe design and test these anchors for cyclic loads resulting from thermal fluctuations. Various concrete embeds in the containment and other structures are subjected to loads such as pipe rupture which results in shear. Since many of the loads are transient by nature, it is necessary to know the load-displacement relationship so that the energy absorption can be determined. The test program for the embeds had the following objectives: determine load-displacement relationship for various size anchors from 6.5 cm 2 to 26 cm 2 with maximum capacities of approximately 650 kN; determine the effect of various anchor width-to-thickness ratios for the same shear area

  15. Evaluation of Penicillin Binding Protein 2a Latex Agglutination Assay for Identification of Methicillin-Resistant Staphylococcus aureus Directly from Blood Cultures

    OpenAIRE

    Chapin, Kimberle C.; Musgnug, Michael C.

    2004-01-01

    The penicillin binding protein 2a (PBP2a) latex agglutination test using a blood culture pellet was compared to the oxacillin screen agar method using isolated colonies. For blood cultures positive for Staphylococcus aureus (n = 70), the direct PBP2a test was 18% sensitive and 100% specific. The PBP2a test shows poor sensitivity when used directly with positive blood cultures.

  16. Weigh Station and Grid Plate Testing

    International Nuclear Information System (INIS)

    PAJUNEN, A.L.

    2000-01-01

    The purpose of this test is to verify that the Shortened Fuel Canister Hook with Certified Scale (i.e. Weigh Station) can be used to weigh an empty canister from the Canister Well and the empty Primary Cleaning Machine (PCM) Strainer Basket from the process table. Drawing H-1-84835, ''Canister Handling Hook for Fuel Retrieval System Process Table,'' provides details of the Shortened Fuel Canister Hook. It is also necessary to verify that the grid plate can be lifted and tilted over a canister in the canister well. This testing shall be performed before N Reactor fuel is processed through the FRS in Phase 3. The Phase 3 Test will repeatedly weigh fuel and scrap canisters and the PCM strainer basket containing N Reactor fuel (Pajunen, et. al, 2000). Advance testing of this weigh station will ensure that accurate fuel weight data can be recorded in the Phase 3 Test. This document satisfies the requirements EN-6-031-00, ''Testing Process'' for a test plan, test specification and test procedure

  17. Cause and countermeasure for heat up of HTTR core support plate at power rise tests

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, Nozomu; Takada, Eiji; Nakagawa, Shigeaki; Tachibana, Yukio; Kawasaki, Kozo; Saikusa, Akio; Kojima, Takao; Iyoku, Tatuo [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment

    2002-01-01

    HTTR has carried out many kinds of tests as power rise tests in which reactor power rises step by step after attained the first criticality. In the tests, temperature of a core support plate reached higher than expected at each power level, the temperature was expected to be higher than the maximum working temperature at 100% power level. Therefore, tests under the high temperature test operation mode, in which the core flow rate was different, were carried out to predict the temperature at 100% power precisely, and investigate the cause of the temperature rise. From the investigation, it was clear that the cause was gap flow in the core support structure. Furthermore, it was estimated that the temperature of the core support plate rose locally due to change in gap width between the core support plate and a seal plate due to change in core pressure drop. The maximum working temperature of the core support plate was revised. The integrity of core support plate under the revised maximum working temperature condition was confirmed by stress analyses. (author)

  18. Environmental testing of flat plate solar cell modules

    Science.gov (United States)

    Griffith, J.; Dumas, L.; Hoffman, A.

    1978-01-01

    Commercially available flat-plate solar cell modules have been subjected to a variety of environmental tests designed to simulate service conditions. Among the tests are those simulating heat and rain, wind-driven rains, humidity and freezing, humidity and heat, humidity with a voltage bias, salt fog, hail impact, and fungus infestation. Tests for optical surface soiling and the combined effects of temperature, humidity and UV irradiation are under development. A correlation has been demonstrated between degradation caused by the qualification tests and such observed field effects as power loss.

  19. Summary of HSST wide-plate crack-arrest tests and analyses

    International Nuclear Information System (INIS)

    Naus, D.J.; Bass, B.R.; Keeney-Walker, J.; Fields, R.J.; DeWit, R.; Low, S.R. III

    1988-01-01

    Eleven wide-plate crack-arrest tests have been completed to date, seven utilizing specimens fabricated from A533B class 1 material (WP-1 series), and four fabricated from a low upper-shelf base material (WP-2 series). With the exception of one test in the WP-1 series and two tests in the WP-2 series which utilized 152-mm-thick specimens, each test utilized a single-edge notched (SEN) plate specimen 1 by 1 by 0.1 m that was subjected to a linear thermal gradient along the plane of crack propagation. Test results exhibit an increase in crack-arrest toughness with temperature, with the rate of increase becoming greater as the temperature increases. When the wide-place test results are combined with other large-specimen results (Japanese ESSO, thermal-shock experiments and pressurized-thermal-shock experiments) the data show a consistent trend in which the K Ia data extends above the limit provided in ASME Section XI. (author)

  20. Orion Boiler Plate Airdrop Test System

    Science.gov (United States)

    Machin, Ricardo A.; Evans, Carol T.

    2013-01-01

    On the 29th of February 2012 the Orion Capsule Parachute Assembly System (CPAS) project attempted to perform an airdrop test of a boilerplate test article for the second time. The first attempt (Cluster Development Test 2, July 2008) to deliver a similar boilerplate from a C-17 using the Low Velocity Air Drop (LVAD) technique resulted in the programmer parachute failing to properly inflate, the test article failing to achieve the desired test initiation conditions, and the test article a total loss. This paper will pick up where the CDT-2 failure investigation left off, describing the test technique that was adopted, and outline the modeling that was performed to gain confidence that the second attempt would be successful. The second boiler plate test (Cluster Development Test 3-3) was indeed a complete success and has subsequently been repeated several times, allowing the CPAS project to proceed with the full scale system level development testing required to integrate the hardware to the first Entry Flight Test vehicle as well as go into the Critical Design Review with minimum risk and a mature design.

  1. Two-Phase Microfluidic Systems for High Throughput Quantification of Agglutination Assays

    KAUST Repository

    Castro, David

    2018-01-01

    assay, with a minimum detection limit of 50 ng/mL using optical image analysis. We compare optical image analysis and light scattering as quantification methods, and demonstrate the first light scattering quantification of agglutination assays in a two

  2. Philosophy, design and testing of a uniform applied load flat plate testing machine

    International Nuclear Information System (INIS)

    Quirk, A.; Crook, C.

    1976-08-01

    The presence of a central crack, and its associated plastic zones may significantly affect distribution of the stress applied by a loading machine, to a test plate. As a result the fracture stress may be affected, usually optimistically. Examples of these effects are discussed. The design of a machine in which the load is uniformly applied to the test specimen is described and preliminary test data presented. (author)

  3. Agglutinating and bactericidal properties of fractions of rabbit anti-Vibrio cholerae serum.

    Science.gov (United States)

    Pike, R M; Chandler, C H

    1969-06-01

    The major portion of the agglutinating and bactericidal activity of the sera of rabbits immunized with live Vibrio cholerae or with cholera vaccine was found in the gammaM fractions during the early stages of immunization. After 5 weeks or more, gammaG fractions accounted for more than half of the agglutinating activity. When late antibody was measured as the amount of protein precipitated by somatic antigens, nearly 3 times as much gammaG as gammaM was required for agglutination, and about 30 times as much gammaG as gammaM was required to kill 50% of a standard inoculum in the presence of complement. The ratio of vibriocidal to agglutinin titer of gammaG fractions at different stages of immunization was more variable than that of gammaM fractions. More complement was required for a vibriocidal effect by gammaG than by gammaM. Increasing the amount of complement decreased the amount of both gammaG and gammaM required to kill, but smaller amounts of gammaM required disproportionately larger amounts of complement. Less time was required by gammaM than by gammaG to kill 50% of the inoculum. Removal of the group-reactive antibody from anti-Ogawa serum and serum fractions by absorption with Inaba reduced the vibriocidal titer by more than one-half.

  4. Diagnosis of Trichomonous vaginalis by microscopy, latex agglutination, diamond's media, and PCR in symptomatic women, Khartoum, Sudan.

    Science.gov (United States)

    Saleh, Amir M; Abdalla, Hamid S; Satti, Abdelsalam B; Babiker, Suad M; Gasim, Gasim I; Adam, Ishag

    2014-03-06

    Trichomoniasis is the most common sexually transmitted disease. However, limited data are available on an effective technique for the diagnosis of Trichomonas vaginalis. A cross-sectional study was conducted to evaluate the accuracy of wet mount microscopy, latex agglutination, Diamond's media, and polymerase chain reaction (PCR) for detection of T. vaginalis among symptomatic women who attended the gynecological clinic at Khartoum, Sudan. Of the 297 women studied, 252 (84.8%) were positive for T. vaginalis by wet mount microscopy, 257 (86.5%) by latex agglutination, 253 (85.2%) by Diamond's media, and 253 (85.2%) by PCR. The sensitivity and specificity of wet mount microscopy were 99.2% and 97.7%, respectively, compared with PCR. The sensitivity and specificity of latex agglutination and Diamond's media were 99.6% and 88.6%, and 100.0% and 86.4%, respectively, compared with PCR. In this study, wet mount microscopy, latex agglutination, and Diamond's media were found to be highly sensitive and specific. However, the availability and cost effectiveness might limit the use of Diamond's media and PCR in routine practice. The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/7859723851211496.

  5. Test Method for High β Particle Emission Rate of 63Ni Source Plate

    OpenAIRE

    ZHANG Li-feng

    2015-01-01

    For the problem of measurement difficulties of β particle emission rate of Ni-63 source plate used for Ni-63 betavoltaic battery, a relative test method of scintillation current method was erected according to the measurement principle of scintillation detector.β particle emission rate of homemade Ni-63 source plate was tested by the method, and the test results were analysed and evaluated, it was initially thought that scintillation current method was a feasible way of testing β particle emi...

  6. The history, development and application of a uniformly applied load wide plate testing machine

    International Nuclear Information System (INIS)

    Quirk, A.; Bevitt, E.

    1989-01-01

    The paper describes early attempts to use a rigid end wide plate testing machine to investigate the behaviour of centre cracked flat plates. Confusing and inconsistent results arising from the above tests lead to a detailed investigation of the loading characteristics of rigid end machines in general and the difficulties which can arise in the interpretation of data obtained by the use of such machines. In order to overcome the above difficulties which stem largely from uneven load distribution, a versatile testing machine was designed which by use of cheap and easily obtainable components allows the application of a uniformly distributed applied load to a centre cracked test plate. The machine which was commissioned in its original form in 1975 was initially capable of testing plate of 820 mm width and 25 or 48 mm thickness up to maximum stress levels of 488 or 254 MPa respectively. The ease of adaptability of the machine has since permitted its capacity to be increased to handle plate up to 2032 mm wide and 76 mm thickness and by use of double-banked hydraulic jacks stress levels up to 350 MPa can be achieved on plate of these dimensions. The configuration of the machine allows adequate access for strain gauging, crack tip observation and measurements, and temperature control, tests having been conducted in the temperature range -40 0 C to 290 0 C. Advantages and potential for further development of the machine are given together with details of two of a number of fracture studies which have been conducted since its commissioning. (orig.)

  7. Structural Changes in Stx1 Engineering Monoclonal Antibody Improves Its Functionality as Diagnostic Tool for a Rapid Latex Agglutination Test

    Directory of Open Access Journals (Sweden)

    Daniela Luz

    2018-02-01

    Full Text Available Stx1 toxin is one of the AB5 toxins of Shiga toxin-producing Escherichia coli (STEC responsible for foodborne intoxication during outbreaks. The single-chain variable fragment (scFv is the most common recombinant antibody format; it consists of both variable chains connected by a peptide linker with conserved specificity and affinity for antigen. The drawbacks of scFv production in bacteria are the heterologous expression, conformation and stability of the molecule, which could change the affinity for the antigen. In this work, we obtained a stable and functional scFv-Stx1 in bacteria, starting from IgG produced by hybridoma cells. After structural modifications, i.e., change in protein orientation, vector and linker, its solubility for expression in bacteria was increased as well as the affinity for its antigen, demonstrated by a scFv dissociation constant (KD of 2.26 × 10−7 M. Also, it was able to recognize purified Stx1 and cross-reacted with Stx2 toxin by ELISA (Enzyme-Linked Immunosorbent Assay, and detected 88% of Stx1-producing strains using a rapid latex agglutination test. Thus, the scFv fragment obtained in the present work is a bacteria-produced tool for use in a rapid diagnosis test, providing an alternative for STEC diagnosis.

  8. Evaluation of surveillance case definition in the diagnosis of leptospirosis, using the Microscopic Agglutination Test: a validation study.

    Science.gov (United States)

    Dassanayake, Dinesh L B; Wimalaratna, Harith; Agampodi, Suneth B; Liyanapathirana, Veranja C; Piyarathna, Thibbotumunuwe A C L; Goonapienuwala, Bimba L

    2009-04-22

    Leptospirosis is endemic in both urban and rural areas of Sri Lanka and there had been many out breaks in the recent past. This study was aimed at validating the leptospirosis surveillance case definition, using the Microscopic Agglutination Test (MAT). The study population consisted of patients with undiagnosed acute febrile illness who were admitted to the medical wards of the Teaching Hospital Kandy, from 1st July 2007 to 31st July 2008. The subjects were screened to diagnose leptospirosis according to the leptospirosis case definition. MAT was performed on blood samples taken from each patient on the 7th day of fever. Leptospirosis case definition was evaluated in regard to sensitivity, specificity and predictive values, using a MAT titre >or= 1:800 for confirming leptospirosis. A total of 123 patients were initially recruited of which 73 had clinical features compatible with the surveillance case definition. Out of the 73 only 57 had a positive MAT result (true positives) leaving 16 as false positives. Out of the 50 who didn't have clinical features compatible with the case definition 45 had a negative MAT as well (true negatives), therefore 5 were false negatives. Total number of MAT positives was 62 out of 123. According to these results the test sensitivity was 91.94%, specificity 73.77%, positive predictive value and negative predictive values were 78.08% and 90% respectively. Diagnostic accuracy of the test was 82.93%. This study confirms that the surveillance case definition has a very high sensitivity and negative predictive value with an average specificity in diagnosing leptospirosis, based on a MAT titre of >or= 1: 800.

  9. Color-discrimination threshold determination using pseudoisochromatic test plates

    Directory of Open Access Journals (Sweden)

    Kaiva eJurasevska

    2014-11-01

    Full Text Available We produced a set of pseudoisochromatic plates for determining individual color-difference thresholds to assess test performance and test properties, and analyzed the results. We report a high test validity and classification ability for the deficiency type and severity level (comparable to that of the fourth edition of the Hardy–Rand–Rittler (HRR test. We discuss changes of the acceptable chromatic shifts from the protan and deutan confusion lines along the CIE xy diagram, and the high correlation of individual color-difference thresholds and the red–green discrimination index. Color vision was tested using an Oculus HMC anomaloscope, a Farnsworth D15, and an HRR test on 273 schoolchildren, and 57 other subjects with previously diagnosed red–green color-vision deficiency.

  10. A latex agglutination test for the field determination of abnormal vitellogenin production in male fishes contaminated by estrogen mimics

    International Nuclear Information System (INIS)

    Magalhaes, Ilizabete; Pihan, Jean-Claude; Falla, Jairo

    2004-01-01

    Estrogen mimics are pollutants present in the aquatic environment. These compounds induce abnormalities in the reproductive system of male fishes, which lead to a total or partial male feminization, or to their demasculinization. Ultimately, these alterations could lead to a disappearance of the total contaminated fish population. Moreover, these toxic substances possess the capacity to mimic endogenous estrogens and to induce the abnormal production of vitellogenin (VTG) in male and immature fishes. The purpose of this research was to develop an easy, specific, cheap and fast method for diagnosing the contamination of male fishes by estrogen mimics, using VTG as biomarker. The selected method is based on a reverse latex agglutination test (rLAT), developed with monoclonal antibodies specific of this biomarker. The development of this VTG-rLAT has involved, firstly, the purification of carp VTG to produce monoclonal antibodies, specifics of this protein. One of these antibodies was selected to recover latex particles (diameter: 1 μm). Finally, the immunoreactivity of the VTG-rLAT was verified with different fish plasma samples from males treated with 17β-estradiol and non-treated males or females in vitellogenesis

  11. Mononucleosis spot test

    Science.gov (United States)

    Monospot test; Heterophile antibody test; Heterophile agglutination test; Paul-Bunnell test; Forssman antibody test ... The mononucleosis spot test is done when symptoms of mononucleosis are ... Fatigue Fever Large spleen (possibly) Sore throat Tender ...

  12. Recent advances in seismic non-destructive testing of concrete plate like structures

    International Nuclear Information System (INIS)

    Ryden, N.; Kristensen, A.; Jovall, O.

    2009-01-01

    This paper describes recent advances in seismic/acoustic non-destructive testing of concrete containment walls. The presented technique is focused on the characterization of the mean stiffness (seismic velocities) and thickness of the containment wall. The Impact Echo (IE) method is a well-established technique to measure the thickness of concrete plates or to locate defects in concrete plate like structures. The method relies on a good estimate of the mean velocity through the thickness of the plate and a precisely measured thickness resonant frequency. Recently the underlying theory of the IE method has been redefined and improved based on Lamb waves in a free plate. Based on this theory we have developed a new data processing technique where both propagating and standing Lamb waves are analysed in a combined manner using multichannel data. With this approach the mean velocity through the plate thickness is evaluated by using the fundamental mode Lamb wave dispersion curves. The accuracy and detection ability of the measured resonant frequency is improved by utilizing both amplitude and phase information from the multichannel record. The method has been tested on several nuclear power plants in Sweden and Finland and proved to be more robust compared to conventional IE and surface wave measurements

  13. An Insight into the proteome of Crithidia fasciculata choanomastigotes as a comparative approach to axenic growth, peanut lectin agglutination and differentiation of Leishmania spp. promastigotes.

    Directory of Open Access Journals (Sweden)

    Pedro J Alcolea

    Full Text Available The life cycle of the trypanosomatid Crithidia fasciculata is monogenetic, as the unique hosts of these parasites are different species of culicids. The comparison of these non-pathogenic microorganisms evolutionary close to other species of trypanosomatids that develop digenetic life cycles and cause chronic severe sickness to millions of people worldwide is of outstanding interest. A ground-breaking analysis of differential protein abundance in Crithidia fasciculata is reported herein. The comparison of the outcome with previous gene expression profiling studies developed in the related human pathogens of the genus Leishmania has revealed substantial differences between the motile stages of these closely related organisms in abundance of proteins involved in catabolism, redox homeostasis, intracellular signalling, and gene expression regulation. As L. major and L. infantum agglutinate with peanut lectin and non-agglutinating parasites are more infective, the agglutination properties were evaluated in C. fasciculata. The result is that choanomastigotes are able to agglutinate with peanut lectin and a non-agglutinating subpopulation can be also isolated. As a difference with L. infantum, the non-agglutinating subpopulation over-expresses the whole machinery for maintenance of redox homeostasis and the translation factors eIF5a, EF1α and EF2, what suggests a relationship between the lack of agglutination and a differentiation process.

  14. Evaluations of corrosion resistance of Ni-Cr plated and Zn-plated Fe Substrates Using an Electrolytic Corrosion Test

    International Nuclear Information System (INIS)

    Lee, Jaebong; Kim, Kyungwook; Park, Minwoo; Song, Taejun; Lee, Chaeseung; Lee, Euijong; Kim, Sangyeol

    2013-01-01

    An Eectrolytic Corrosion(EC) test method was evaluated by the comparison with Copper Accelerated Acetic Salt Spray(CASS) and Neutral Salt Spray(SS) tests. Those methods were applied in order to evaluate corrosion resistance of Ni-Cr plated and Zn-plated Fe substrates. The correlations between results obtained by different test methods were investigated. Results showed that the electrochemical method such as the EC test method was superior to the conventional methods such as CASS and SS, in terms of the quantitative accuracy and the test-time span. Furthermore, the EC test method provided the useful means to estimate the initiation of corrosion of each layer by monitoring the rest potentials of the coated layers such as Ni, Cr, and Zn on Fe substrate. With regard to test time spans, the EC test provided the 78 times and 182 times faster results than the CASS test in cases of Fe + 5μm Ni + 0.5 μm Cr and Fe + 20 μm Ni + 0.5 μm Cr respectively, while the EC test was 85 times faster results than the Salt Spray test in the case of Fe + 20 g/m 2 Zn. Therefore, the EC test can be the better method to evaluate the resistance to corrosion of coated layers than the conventional methods such as the SS test and the CASS

  15. Multispectral analysis and cone signal modelling of pseudoisochromatic test plates

    International Nuclear Information System (INIS)

    Luse, K; Ozolinsh, M; Gutmane, A; Fomins, S

    2013-01-01

    The aim of the study is to determine the consistency of the desired colour reproduction of the stimuli using calibrated printing technology available to anyone (EpsonStylus Pro 7800 printer was). 24 colour vision assessment plates created in the University of Latvia were analysed right after their fabrication on august 2012 and after intense use for 7 months (colour vision screening on 700 people). Multispectral imagery results indicate that the alignment of the samples after seven months of use has maintained on the CIExy confusion lines of deutan deficiency type, but the shift towards achromatic area in the diagram indicate decrease in the total colour difference (ΔE* ab ) of test background (achromatic) areas and stimuli (chromatic) areas, thus affecting the testing outcome and deficiency severity level classification ability of the plates

  16. Widal agglutination titre: a rapid serological diagnosis of typhoid fever in developing countries

    International Nuclear Information System (INIS)

    Aftab, R.; Khurshid, R.

    2009-01-01

    To study the reliability of a single Widal test and to find out the diagnostic significance of 'O' and 'H' agglutinin titre in the diagnosis of typhoid fever. Community-based case-control study conducted from Jan 2001 to June 2007. The blood samples were collected from the medical and out door department of Sir Ganga Ram Hospitals, Lahore. The diagnostic value of an acute phase single Widal agglutination test for suspected typhoid fever was evaluated in 733 consecutive patients with fever lasting 6 or more days. In 733 patients with fever 84 (11.45%) were positive for Widal test. A noteworthy rise 1/320 of H and/or O agglutinin titre was observed in 86 (11.3%) of patients with typhoid fever. In the absence of vaccination an elevated level of H and/or O agglutinin titre of 1: 320 is of diagnostic value for typhoid fever especially in our setting where a single sample of serum is relied on for the diagnosis of typhoid fever. (author)

  17. Widal agglutination titre: a rapid serological diagnosis of typhoid fever in developing countries

    Energy Technology Data Exchange (ETDEWEB)

    Aftab, R [Fatima Jinnah Medical College Lahore, Lahore (Pakistan). Dept. of Pathology; Khurshid, R [Fatima Jinnah Medical College Lahore, Lahore (Pakistan). Dept. of Biochemistry

    2009-01-15

    To study the reliability of a single Widal test and to find out the diagnostic significance of 'O' and 'H' agglutinin titre in the diagnosis of typhoid fever. Community-based case-control study conducted from Jan 2001 to June 2007. The blood samples were collected from the medical and out door department of Sir Ganga Ram Hospitals, Lahore. The diagnostic value of an acute phase single Widal agglutination test for suspected typhoid fever was evaluated in 733 consecutive patients with fever lasting 6 or more days. In 733 patients with fever 84 (11.45%) were positive for Widal test. A noteworthy rise 1/320 of H and/or O agglutinin titre was observed in 86 (11.3%) of patients with typhoid fever. In the absence of vaccination an elevated level of H and/or O agglutinin titre of 1: 320 is of diagnostic value for typhoid fever especially in our setting where a single sample of serum is relied on for the diagnosis of typhoid fever. (author)

  18. Characterization of Rubbers from Spherical Punch - Plate Indentation Tests

    Directory of Open Access Journals (Sweden)

    Florina Carmen Ciornei

    2016-12-01

    Full Text Available Rubber plates with different compositions and hardness were tested by continuous indentation, using a spherical punch and hysteretic phenomenon was evidenced. The experimental data interpolation with polynomial functions is accurate and permits estimation of the lost work during loading cycles. The interpolation by power law functions is more convenient by using less parameters and having a form accepted in literature. From the rubbers tested, two were considered to present good damping properties.

  19. Direct detection of methicillin resistance in Staphylococcus aureus in blood culture broth by use of a penicillin binding protein 2a latex agglutination test.

    Science.gov (United States)

    Qian, Qinfang; Venkataraman, Lata; Kirby, James E; Gold, Howard S; Yamazumi, Toshiaki

    2010-04-01

    We studied the utility of performing a penicillin binding protein 2a latex agglutination (PBP-LA) assay directly on Bactec blood culture broth samples containing Staphylococcus aureus to rapidly detect methicillin resistance. The sensitivity, specificity, positive predictive value, and negative predictive value of this method were 94.1%, 97.5%, 98%, and 92.9%, respectively.

  20. Anatomical Thin Titanium Mesh Plate Structural Optimization for Zygomatic-Maxillary Complex Fracture under Fatigue Testing

    Directory of Open Access Journals (Sweden)

    Yu-Tzu Wang

    2018-01-01

    Full Text Available This study performs a structural optimization of anatomical thin titanium mesh (ATTM plate and optimal designed ATTM plate fabricated using additive manufacturing (AM to verify its stabilization under fatigue testing. Finite element (FE analysis was used to simulate the structural bending resistance of a regular ATTM plate. The Taguchi method was employed to identify the significance of each design factor in controlling the deflection and determine an optimal combination of designed factors. The optimal designed ATTM plate with patient-matched facial contour was fabricated using AM and applied to a ZMC comminuted fracture to evaluate the resting maxillary micromotion/strain under fatigue testing. The Taguchi analysis found that the ATTM plate required a designed internal hole distance to be 0.9 mm, internal hole diameter to be 1 mm, plate thickness to be 0.8 mm, and plate height to be 10 mm. The designed plate thickness factor primarily dominated the bending resistance up to 78% importance. The averaged micromotion (displacement and strain of the maxillary bone showed that ZMC fracture fixation using the miniplate was significantly higher than those using the AM optimal designed ATTM plate. This study concluded that the optimal designed ATTM plate with enough strength to resist the bending effect can be obtained by combining FE and Taguchi analyses. The optimal designed ATTM plate with patient-matched facial contour fabricated using AM provides superior stabilization for ZMC comminuted fractured bone segments.

  1. Environmental testing of terrestrial flat plate photovoltaic modules

    Science.gov (United States)

    Hoffman, A.; Griffith, J.

    1979-01-01

    The Low-Cost Solar Array (LSA) Project at the Jet Propulsion Laboratory has as one objective: the development and implementation of environmental tests for flat plate photovoltaic modules as part of the Department of Energy's terrestrial photovoltaic program. Modules procured under this program have been subjected to a variety of laboratory tests intended to simulate service environments, and the results of these tests have been compared to available data from actual field service. This comparison indicates that certain tests (notably temperature cycling, humidity cycling, and cyclic pressure loading) are effective indicators of some forms of field failures. Other tests have yielded results useful in formulating module design guidelines. Not all effects noted in field service have been successfully reproduced in the laboratory, however, and work is continuing in order to improve the value of the test program as a tool for evaluating module design and workmanship. This paper contains a review of these ongoing efforts and an assessment of significant test results to date.

  2. Correlation potential of a test ion near a strongly charged plate.

    Science.gov (United States)

    Lu, Bing-Sui; Xing, Xiangjun

    2014-03-01

    We analytically calculate the correlation potential of a test ion near a strongly charged plate inside a dilute m:-n electrolyte. We do this by calculating the electrostatic Green's function in the presence of a nonlinear background potential, the latter having been obtained using the nonlinear Poisson-Boltzmann theory. We consider the general case where the dielectric constants of the plate and the electrolyte are distinct. The following generic results emerge from our analyses: (1) If the distance to the plate Δz is much larger than a Gouy-Chapman length, the plate surface will behave effectively as an infinitely charged surface, and the dielectric constant of the plate effectively plays no role. (2) If Δz is larger than a Gouy-Chapman length but shorter than a Debye length, the correlation potential can be interpreted in terms of an image charge that is three times larger than the source charge. This behavior is independent of the valences of the ions. (3) The Green's function vanishes inside the plate if the surface charge density is infinitely large; hence the electrostatic potential is constant there. In this respect, a strongly charged plate behaves like a conductor plate. (4) If Δz is smaller than a Gouy-Chapman length, the correlation potential is dominated by the conventional image charge due to the dielectric discontinuity at the interface. (5) If Δz is larger than a Debye length, the leading order behavior of the correlation potential will depend on the valences of the ions in the electrolyte. Furthermore, inside an asymmetric electrolyte, the correlation potential is singly screened, i.e., it undergoes exponential decay with a decay width equal to the Debye length.

  3. Proposed method for agglutinating antibody titer analysis and its use as indicator of acquired immunity in pacu, Piaractus mesopotamicus

    Directory of Open Access Journals (Sweden)

    JD Biller-Takahashi

    Full Text Available Antibody can be assessed by agglutinating antibody titer which is a quantitative measure of circulating antibodies in serum from fish previously immunized. The antibody evaluation has been performed with different fish species, and is considered a reliable method that can be applied to confirm several hypothesis regarding acquired immunity, even in conjunction with precise methods to describe immune mechanisms. In order to provide appropriate analytical methods for future studies on the specific immune system of native fish, the present study standardized on assay to measure the serum agglutinating antibody titer produced after immunization with inactivated A. hydrophila and levamisole administration in pacu. It was possible to determine the agglutinating antibodies titer in a satisfactorily way in pacu immunized with inactive A. hydrophila, and the highest titers were observed on fish fed with levamisole.

  4. Novel platelet-agglutinating protein from a thrombotic thrombocytopenic purpura plasma.

    OpenAIRE

    Siddiqui, F A; Lian, E C

    1985-01-01

    A novel platelet-agglutinating protein (PAP) was purified approximately 2,000-fold from the plasma of a patient with thrombotic thrombocytopenic purpura (TTP) by ammonium sulfate fractionation, DEAE-Sephacel and concanavalin A-Sepharose chromatographies. On sodium dodecyl sulfate-polyacrylamide gel electrophoresis, with and without reduction, this preparation revealed a major protein band with a molecular weight of 37,000, and a minor band with a molecular weight of 32,000-34,000. After eluti...

  5. Prevalence of agglutinating antibodies to Sarcocystis neurona in skunks (Mephitis Mephitis), raccoons (Procyon lotor), and opossums (Didelphis Virginiana) from Connecticut.

    Science.gov (United States)

    Mitchell, Sheila M; Richardson, Dennis J; Cheadle, M Andy; Zajac, Anne M; Lindsay, David S

    2002-10-01

    Equine protozoal myeloencephalitis is the most important protozoan disease of horses in North America and is usually caused by Sarcocystis neurona. Natural cases of encephalitis caused by S. neurona have been reported in skunks (Mephitis mephitis) and raccoons (Procyon lotor). Opossums (Didelphis spp.) are the only known definitive host. Sera from 24 striped skunks, 12 raccoons, and 7 opossums (D. virginiana) from Connecticut were examined for agglutinating antibodies to S. neurona using the S. neurona agglutination test (SAT) employing formalin-fixed merozoites as antigen. The SAT was validated for skunk sera using pre- and postinfection serum samples from 2 experimentally infected skunks. Of the 24 (46%) skunks 11 were positive, and all 12 raccoons were positive for S. neurona antibodies. None of the 7 opossums was positive for antibodies to S. neurona. These results suggest that exposure to sporocysts of S. neurona by intermediate hosts is high in Connecticut. The absence of antibodies in opossums collected from the same areas is most likely because of the absence of systemic infection in the definitive host.

  6. Use of commercial extenders and alternatives to prevent sperm agglutination for cryopreservation of brown bear semen.

    Science.gov (United States)

    Gomes-Alves, S; Alvarez, M; Nicolas, M; Lopez-Urueña, E; Martínez-Rodríguez, C; Borragan, S; de Paz, P; Anel, L

    2014-08-01

    The objective of this study was to evaluate different bovine and canine commercial semen extenders for cryopreservation of brown bear ejaculates and the effect of semen collection directly into extender on sperm agglutination. Semen samples were obtained by electroejaculation from 13 adult males. In experiment 1, eleven ejaculates from eight bears were used to evaluate Bioxcell and Andromed as extenders, whereas in experiment 2, nine ejaculates from six bears were used to evaluate Triladyl canine, CaniPro, and Extender 2 as extenders. An extender specifically developed for brown bears (Test-Tris-fructose-egg yolk-glycerol, TTF-ULE/bear) served as a control extender in both experiments. After thawing, total and progressive sperm motility and sperm viability were greater (P bear and Andromed extenders than for Bioxcell in experiment 1 and greater (P bear extender than for Triladyl Canine, CaniPro, and Extender 2 in experiment 2. In experiment 3, addition of handling extender (TTF-H) to the semen collection tube for eight ejaculates from seven bears resulted in less (P bear is the most suitable extender for brown bear semen cryopreservation, but comparable results can be obtained with the commercial extender Andromed. In addition, collection of ejaculates directly in TTF-H extender decreases sperm agglutination in fresh samples. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Comparison of identification and antimicrobial resistance pattern of ...

    African Journals Online (AJOL)

    The identified isolates were compared with presumptive identities obtained by growth on MSA, tube coagulation and slide agglutination tests. Antimicrobial susceptibility testing of S. aureus isolates was performed by Kirby Bauer technique while MRSA was screened for by growth on chromIDTM MRSA plate and confirmed ...

  8. Experiment and simulation of double-layered RC plates under impact loadings. Part 1: Impact tests for double-layered RC plates

    International Nuclear Information System (INIS)

    Shirai, T.; Ueda, M.; Taniguchi, H.; Kambayashi, A.; Ohno, T.; Ishikawa, N.

    1993-01-01

    At a nuclear power plant facility, it should be of interest and important problem to ensure structures against impact loads induced by projectile impacts or plant-internal accidents. It has been well known that local damage consists of spalling of concrete from the impacted area and scabbing of concrete from the back face of the target together with projectile penetration into the target. There are several techniques for improving the impact resistance of RC slabs, that is, lining with a steel plate on the impacted and/or rear face of the slab, making the slab a double-layered composite slab with an elastic absorber and employing a fiber reinforced concrete or a high-strength concrete as the slab materials. Of the many measures available for withstanding impact loads, the use of a double-layered reinforced concrete (RC) slab with absorber is expected to have the higher resistance in reducing or preventing local damage. This paper presents the results of an experimental investigation on the impact resistance of double-layered RC plates subjected to the impact of projectile. In the experiment, the effects of two parameters; the combination of two RC plates having different thicknesses and the existence of an absorber in the middle layer, are mainly investigated. And, the effects of the concrete thickness (7,9 and 11 cm) and the concrete strength (a normal-:35MPa, a lightweight-:40MPa and a high-strength:57MPa) of target were also examined. RC plates, 0.6m-square, were used for test specimens. The projectile has a mass of 0.43kg, made of steel with a flat nose. An average projectile velocity was about 170m/sec. A rubber plate shaped into a square with the same size of RC plate was used for a double-layered specimen as an absorber which was put between two RC plates. It could be concluded that double-layering and presence of an absorber had a considerable effect on the increase of impact resistance of RC plate. In order to reduce local damage, it is more effective to

  9. Resistive Plate Chambers for hadron calorimetry: Tests with analog readout

    Energy Technology Data Exchange (ETDEWEB)

    Drake, Gary [Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, IL 60439 (United States); Repond, Jose [Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, IL 60439 (United States)]. E-mail: repond@hep.anl.gov; Underwood, David [Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, IL 60439 (United States); Xia, Lei [Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, IL 60439 (United States)

    2007-07-21

    Resistive Plate Chambers (RPCs) are being developed for use in a hadron calorimeter with very fine segmentation of the readout. The design of the chambers and various tests with cosmic rays are described. This paper reports on the measurements with multi-bit (or analog) readout of either a single larger or multiple smaller readout pads.

  10. Elevated-temperature tests of simply-supported beams and circular plates subjected to time-varying loadings

    International Nuclear Information System (INIS)

    Corum, J.M.; Richardson, M.

    1975-01-01

    The measured elastic-plastic and elastic-plastic-creep responses of a number of simply-supported type 304 stainless steel beams and circular plates are presented. Beams and plates exhibit the essential features of inelastic structural behavior; yet they are relatively simple. In beams, the stress fields are largely uniaxial, while multiaxial effects are introduced in plates. The specimens were laterally loaded at the center, and the tests were performed by subjecting the specimens to either a prescribed load or center-deflection history. The specimens were machined from a common, well-characterized heat of material, and all of the tests were performed at a temperature of 1100 F. The elastic-plastic tests consisted of short-time cycling of the center load, or deflection, between fixed limits. In the elastic-plastic-creep tests the center load, or deflection, was held constant for periods of time, but was periodically subjected to a step increase or decrease, including reversals. The test results are presented in terms of the load and center-deflection behaviors, which typify the overall structural behavior. (U.S.)

  11. Two-Dimensional Mapping of the Calculated Fission Power for the Full-Size Fuel Plate Experiment Irradiated in the Advanced Test Reactor

    Science.gov (United States)

    Chang, G. S.; Lillo, M. A.

    2009-08-01

    The National Nuclear Security Administrations (NNSA) Reduced Enrichment for Research and Test Reactors (RERTR) program assigned to the Idaho National Laboratory (INL) the responsibility of developing and demonstrating high uranium density research reactor fuel forms to enable the use of low enriched uranium (LEU) in research and test reactors around the world. A series of full-size fuel plate experiments have been proposed for irradiation testing in the center flux trap (CFT) position of the Advanced Test Reactor (ATR). These full-size fuel plate tests are designated as the AFIP tests. The AFIP nominal fuel zone is rectangular in shape having a designed length of 21.5-in (54.61-cm), width of 1.6-in (4.064-cm), and uniform thickness of 0.014-in (0.03556-cm). This gives a nominal fuel zone volume of 0.482 in3 (7.89 cm3) per fuel plate. The AFIP test assembly has two test positions. Each test position is designed to hold 2 full-size plates, for a total of 4 full-size plates per test assembly. The AFIP test plates will be irradiated at a peak surface heat flux of about 350 W/cm2 and discharged at a peak U-235 burn-up of about 70 at.%. Based on limited irradiation testing of the monolithic (U-10Mo) fuel form, it is desirable to keep the peak fuel temperature below 250°C to achieve this, it will be necessary to keep plate heat fluxes below 500 W/cm2. Due to the heavy U-235 loading and a plate width of 1.6-in (4.064-cm), the neutron self-shielding will increase the local-to-average-ratio (L2AR) fission power near the sides of the fuel plates. To demonstrate that the AFIP experiment will meet the ATR safety requirements, a very detailed 2-dimensional (2D) Y-Z fission power profile was evaluated in order to best predict the fuel plate temperature distribution. The ability to accurately predict fuel plate power and burnup are essential to both the design of the AFIP tests as well as evaluation of the irradiated fuel performance. To support this need, a detailed MCNP Y

  12. Misidentification of Vibrio cholerae O155 isolated from imported shrimp as O serogroup O139 due to cross-agglutination with commercial O139 antisera

    DEFF Research Database (Denmark)

    Dalsgaard, A.; Mazur, J.; Dalsgaard, Inger

    2002-01-01

    . The strain contained two plasmids, in contrast to other O139 strains, which normally do not contain plasmids. The characteristics of the strain led to further agglutination testing with other antisera that are not commercially available, and the strain was found to agglutinate O155 antiserum in repeated...... was isolated from imported raw frozen shrimp. The toxigenicity of the strain was analyzed, and the results of a polymerase chain reaction showed that the V. cholerae strain did not contain the virulence genes ctx, tcp9, and zot, which are normally found in V. cholerae O1 and O139. The strain was resistant...... to colistin and spectinomycin. The high susceptibility of the strain to antimicrobial agents was confirmed by the lack of an SXT element, a self-transmissible, chromosomal genetic element that is normally present in O139 strains and encodes resistance to sulfonamides, trimethoprim, and streptomycin...

  13. Results from low cycle fatigue testing of 316L plate and weld material

    International Nuclear Information System (INIS)

    Kaellstroem, R.; Josefsson, B.; Haag, Y.

    1993-01-01

    Specimens for low cycle fatigue testing from the second heat of the CEC reference 316L plate and from Tungsten Inert Gas (TIG) weld material have been neutron irradiated near room temperature to a displacement dose of approximately 0.3 dpa. The low cycle fatigue testing of both irradiated and unirradiated specimens was performed at 75, 250 and 450 degrees C, and with strain ranges of 0.75, 1.0 and 1.5%. There is no clear effect of the irradiation on low cycle fatigue properties. For the weld material the endurance is shorter than for plate, and the dependences on temperature and strain range are not clear

  14. Impacts of papain and neuraminidase enzyme treatment on electrohydrodynamics and IgG-mediated agglutination of type A red blood cells.

    Science.gov (United States)

    Hyono, Atsushi; Gaboriaud, Fabien; Mazda, Toshio; Takata, Youichi; Ohshima, Hiroyuki; Duval, Jérôme F L

    2009-09-15

    The stability of native and enzyme-treated human red blood cells of type A (Rh D positive) against agglutination is investigated under conditions where it is mediated by immunoglobuline G (IgG) anti-D antibody binding. The propensity of cells to agglutinate is related to their interphasic (electrokinetic) properties. These properties significantly depend on the concentration of proteolytic papain enzyme and protease-free neuraminidase enzyme that the cells are exposed to. The analysis is based on the interpretation of electrophoretic data of cells by means of the numerical theory for the electrokinetics of soft (bio)particles. A significant reduction of the hydrodynamic permeability of the external soft glycoprotein layer of the cells is reported under the action of papain. This reflects a significant decrease in soft surface layer thickness and a loss in cell surface integrity/rigidity, as confirmed by nanomechanical AFM analysis. Neuraminidase action leads to an important decrease in the interphase charge density by removing sialic acids from the cell soft surface layer. This is accompanied by hydrodynamic softness modulations less significant than those observed for papain-treated cells. On the basis of these electrohydrodynamic characteristics, the overall interaction potential profiles between two native cells and two enzyme-treated cells are derived as a function of the soft surface layer thickness in the Debye-Hückel limit that is valid for cell suspensions under physiological conditions (approximately 0.16 M). The thermodynamic computation of cell suspension stability against IgG-mediated agglutination then reveals that a decrease in the cell surface layer thickness is more favorable than a decrease in interphase charge density for inducing agglutination. This is experimentally confirmed by agglutination data collected for papain- and neuraminidase-treated cells.

  15. Prevalence of agglutinating antibodies to Toxoplasma gondii and Sarcocystis neurona in beavers (Castor canadensis) from Massachusetts

    Science.gov (United States)

    Jordan, C.N.; Kaur, T.; Koenen, K.; DeStefano, S.; Zajac, A.M.; Lindsay, D.S.

    2005-01-01

    The present study examined the seroprevalence of Toxoplasma gondii and Sarcocystls neurona in a population of beavers (Castor canadensis) from Massachusetts. Sixty-two blood samples were collected during the field seasons over 3 consecutive years from different animals. Blood was collected onto filter paper and shipped to the Department of Biomedical Sciences, Virginia Tech, Blacksburg, Virginia, for parasite testing. The samples were tested at dilutions of 1:25, 1:50, and 1:100 against each parasite antigen by modified agglutination tests to determine whether antibodies to either parasite were present in the blood. Six of 62 samples (10%) were positive for T. gondii, with 2 samples having titers of 1:25 and 4 having titers of 1:50. Four of 62 samples (6%) were positive for S. neurona, with 2 samples having titers of 1:25 and 2 having titers of 1:50. ?? American Society of Pathologists 2005.

  16. Elevated-temperature benchmark tests of simply supported beams and circular plates subjected to time-varying loadings

    International Nuclear Information System (INIS)

    Corum, J.M.; Richardson, M.; Clinard, J.A.

    1977-01-01

    This report presents the measured elastic-plastic-creep responses of eight simply supported type 304 stainless steel beams and circular plates that were subjected to time-varying loadings at elevated temperature. The tests were performed to provide experimental benchmark problem data suitable for assessing inelastic analysis methods and for validating computer programs. Beams and plates exhibit the essential features of inelastic structural behavior; yet they are relatively simple and the experimental results are generally easy to interpret. The stress fields are largely uniaxial in beams, while multiaxial effects are introduced in plates. The specimens tested were laterally loaded at the center and subjected to either a prescribed load or a center deflection history. The specimens were machined from a common well-characterized heat of material, and all the tests were performed at a temperature of 593 0 C (1100 0 F). Test results are presented in terms of the load and center deflection behaviors, which typify the overall structural behavior. Additional deflection data, as well as strain gage results and mechanical properties data for the beam and plate material, are provided in the appendices

  17. On a grain of sand - a microhabitat for the opportunistic agglutinated foraminifera Hemisphaerammina apta n. sp., from the early Eocene Arctic Ocean

    Science.gov (United States)

    McNeil, David H.; Neville, Lisa A.

    2018-02-01

    Hemisphaerammina apta n. sp. is an attached monothalamous agglutinated foraminifera discovered in shelf sediments of the early Eocene Arctic Ocean. It is a simple yet distinctive component of the endemic agglutinated foraminiferal assemblage that colonized the Arctic Ocean after the microfaunal turnover caused by the Paleocene-Eocene Thermal Maximum. Associated foraminifera are characterized by a high percentage of monothalamous species (up to 60 %) and are entirely agglutinated indicating a brackish (mesohaline) early Eocene Arctic Ocean. Hemisphaerammina apta occurs exclusively as individuals attached to fine detrital grains (0.2 to 1.8 mm) of sediment. It is a small species (0.06 to 0.2 mm in diameter), fine-grained, with a low hemispherical profile, no floor across the attachment area, no substantive marginal flange, no internal structures, and no aperture. Lacking an aperture, it apparently propagated and fed through minute (micrometre-sized) interstitial pores in the test wall. Attachment surfaces vary from concave to convex and rough to smooth. Grains for attachment are diverse in shape and type but are predominantly of quartz and chert. The presence of H. apta in the early Eocene was an opportunistic response to an environment with an active hydrological system (storm events). Attachment to grains of sand would provide a more stable base on a sea floor winnowed by storm-generated currents. Active transport is indicated by the relative abundance of reworked foraminifera mixed with in situ species. Contemporaneous reworking and colonization by H. apta is suggested by its attachment to a reworked specimen of Cretaceous foraminifera.

  18. Sperm Impairment by Sperm Agglutinating Factor Isolated from Escherichia coli: Receptor Specific Interactions

    Directory of Open Access Journals (Sweden)

    Kiranjeet Kaur

    2013-01-01

    Full Text Available In an earlier work done in our laboratory, we have been able to isolate a sperm agglutinating strain of Escherichia coli from the semen sample of a male attending infertility clinic. Further, factor responsible for sperm agglutination (SAF was isolated and purified, and, using SAF as a tool, corresponding SAF binding receptor from human spermatozoa has been purified. Characterization of SAF and SAF binding receptor using MALDI-TOF showed homology to glutamate decarboxylase and MHC class I molecule, respectively. Coincubation of SAF with spermatozoa not only resulted in spermagglutination but could also compromise other sperm parameters, namely, Mg2+ dependent ATPase activity and apoptosis. Intravaginal administration of SAF could lead to infertility in Balb/c mice. SAF induced impairment of sperm parameters, and infertility was observed to be due to interaction of SAF with sperm surface receptor component as, when purified receptor was introduced, receptor completely inhibited all the detrimental effects induced by SAF. From these results, it could be concluded that interaction of SAF with spermatozoa is receptor mediated.

  19. Author Details

    African Journals Online (AJOL)

    Relative performance of buffered Rose Bengal plate test (RBPT) and slow (tube) agglutination test (SAT) for detection of Brucella abortus antibodies in indigenous boran cattle in Tanzania Abstract · Vol 28 (2013): Special Issue - Articles Spatial distribution of non-clinical Rift Valley fever viral activity in domestic and wild ...

  20. Can ultrasound of plantar plate have normal appearance with a positive drawer test?

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Eloy de Avila [Affiliated Professor, Department of Diagnostic Imaging, Escola Paulista de Medicina, Universidade Federal de São Paulo (EPM-Unifesp), São Paulo (Brazil); Mann, Tania Szejnfeld [Medical Assistant of Medicine and Surgery of the Foot and Ankle Group, Department of Orthopedics and Traumatology, EPM-Unifesp, São Paulo (Brazil); Puchnick, Andrea, E-mail: andrea.ddi@epm.br [Professor and Coordinator of Educational and Research Support, Department of Diagnostic Imaging, EPM-Unifesp, São Paulo (Brazil); Tertulino, Franklin de Freitas [Postgraduate Physician, Department of Diagnostic Imaging, EPM-Unifesp, São Paulo (Brazil); Cannato, Camila Testoni [Resident Physician, Department of Surgery, EPM-Unifesp, São Paulo (Brazil); Nery, Caio [Associate Professor, Department of Orthopedics and Traumatology, EPM-Unifesp, São Paulo (Brazil); Fernandes, Artur da Rocha Corrêa [Associate Professor, Department of Diagnostic Imaging, EPM-Unifesp, São Paulo (Brazil)

    2015-03-15

    Highlights: •We evaluate the accuracy of ultrasound to identify and measure the plantar plate. •We correlate ultrasound findings with those of physical examination and MRI. •Ultrasound and MRI measures of plantar plate were positively correlated. •Ultrasound is efficient in identifying and measuring plantar plate. •Ultrasound may complement physical examination. •Young asymptomatic subjects can present a grade I positive drawer test. -- Abstract: Objectives: The aims of this study were (1) to evaluate the reliability of ultrasound (US) examination in the identification and measurement of the metatarsophalangeal plantar plate (MTP-PP) in asymptomatic subjects and (2) to establish the correlation of US findings with those of physical examination and magnetic resonance imaging (MRI), once it is an important tool in the evaluation of the instability syndrome of the second and third rays. Materials and Methods: US examinations of the second and third MTP-PPs were performed in eight asymptomatic volunteers, totaling 32 MTP joints, by three examiners with different levels of experience in musculoskeletal US. Plantar plate dimensions, integrity and echogenicity, the presence of ruptures, and confidence level in terms of structure identification were determined using conventional US. Vascular flow was assessed using power Doppler. US data were correlated with data from physical examination and MRI. Results: MTP-PPs were ultrasonographically identified in 100% of cases, always showing homogeneous hyperechoic features and no detectable vascular flow on power Doppler, with 100% certainty in identification for all examiners. There was excellent US inter-observer agreement for longitudinal measures of second and third toe MTP-PPs and for transverse measures of the second toe MTP-PP. The MTP drawer test was positive for grade 1 MTP instability in 34.4% of joints with normal US results. Transverse MTP-PP measures were significantly higher in individuals with positive

  1. Characterization of holding brake friction pad surface after pin-on-plate wear test

    DEFF Research Database (Denmark)

    Drago, N.; Gonzalez Madruga, D.; De Chiffre, L.

    2018-01-01

    This article concerns the metrological characterization of the surface on a holding brake friction material pin after a pin-on-plate (POP) wear test. The POP test induces the formation of surface plateaus that affect brake performances such as wear, friction, noise and heat. Three different...

  2. Serological response to an indirect and a competitive elisa in heifers vaccinated with Brucella abortus strain 19

    International Nuclear Information System (INIS)

    Carrasco, E.A.; Uzal, F.A.; Echaide, S.

    1998-01-01

    The different serologic techniques for bovine brucellosis diagnosis have different abilities to detect antibodies after vaccination with Brucella abortus strain 19. The humoral response in heifers vaccinated with Brucella abortus strain 19 was evaluated by using several serologic techniques. In the experimental field of INTA, Pilcaniyeu, Rio Negro province, sixteen 5 months old heifers were vaccinated subcutaneously with a standard dose (2ml, containing 20x10 9 to 10x10 9 living organisms) of Brucella abortus strain 19. Sera from all the heifers were obtained on 18 occasions (one 87 days before vaccination, one immediately before vaccination and on 16 occasions after vaccination, during 488 days) and analyzed by buffered plate antigen test, rose bengal test, standard tube agglutination test, 2-mercaptoetanol test, complement fixation test, indirect ELISA, and competitive ELISA. Prior vaccination, 100% of the heifers gave negative results in all the techniques used, while 100% of them gave positive reaction in the first sampling after vaccination to all the techniques, with the exception of standard tube agglutination test that showed agglutinating titters of 1/100 or higher (positive threshold) in only 71.4% of the heifers. The indirect ELISA technique showed a reducing percentage of positive animals up until 316 days after vaccination, after which positive results were obtained. The competitive ELISA gave positive results in a variable number of heifers up to 253 days after vaccination when 100% of the sera were negative to this technique. Buffered plate antigen test was the technique that gave positive results for a longest period, being 100% of the animals negative to this technique at 450 days after vaccination. The other serological techniques assayed gave positive results during variable periods of time, intermediate between standard tube agglutination test and buffered plate antigen test. Although the present results were obtained from a limited number of

  3. Effect of plate shapes in orifice plate type flowmeters

    International Nuclear Information System (INIS)

    Moeller, S.V.

    1984-01-01

    The study of unusual plate shapes in orifice plate type flowmeters is presented, with a view to providing data for the substitution of the plate with one centered circular orifice in those applications where its use is not possible. For this purpose, six pairs of plates with different forms, with and without chamfered edges, were made and tested in a closed water loop. Results show that, generally, the use of chamfers improves the results and, in the case of perforated and slotlike orificed plates, the narrow-ness of the fluid passage tends to make unnecessary its use. (Author) [pt

  4. Electromagnetic Acoustic Test of the Artificial Defects for a Plate-type Nuclear Fuel

    International Nuclear Information System (INIS)

    Jung, Hyun Kyu; Kim, Dong Min; Lee, Yoon Sang; Cheong, Yong Moo

    2011-01-01

    Most research and test reactors use the nuclear fuel plates which are consisted of a fuel meat in aluminum alloy. Last year, KAERI signed a deal with the Jordan Atomic Energy Commission to build the research reactor and have to supply the plate-type nuclear fuels. For the demands of world market, KAERI started the research and development of the plate-type fuel elements and endeavored to achieve a localization of the plate-type fuel fabrication. For the inspection of plate-type fuel elements to be used in Research Reactors, an immersion pulse-echo ultrasonic technique was applied. This inspection was done under immersion condition, so a nuclear fuel was immersed to be prone to corrosion and needed to have time and cost due to an additional process. The sample that will be examined is a non-ferromagnetic material such as aluminum with a good acousto-elastic property, which requires an effective inspection of a bond quality for a nuclear fuel under a manufacturing environment. The purpose of this study is to investigate the feasibility of an Electromagnetic Acoustic Transducer (EMAT) technology for an automated inspection of a nuclear fuel without water

  5. A device for testing the dynamic performance of in situ force plates.

    Science.gov (United States)

    East, Rebecca H; Noble, Jonathan J; Arscott, Richard A; Shortland, Adam P

    2017-09-01

    Force plates are often incorporated into motion capture systems for the calculation of joint kinetic variables and other data. This project aimed to create a system that could be used to check the dynamic performance of force plate in situ. The proposed solution involved the design and development of an eccentrically loaded wheel mounted on a weighted frame. The frame was designed to hold a wheel mounted in two orthogonal positions. The wheel was placed on the force plate and spun. A VICON™ motion analysis system captured the positional data of the markers placed around the rim of the wheel which was used to create a simulated force profile, and the force profile was dependent on spin speed. The root mean square error between the simulated force profile and the force plate measurement was calculated. For nine trials conducted, the root mean square error between the two simultaneous measures of force was calculated. The difference between the force profiles in the x- and y-directions is approximately 2%. The difference in the z-direction was under 0.5%. The eccentrically loaded wheel produced a predictable centripetal force in the plane of the wheel which varied in direction as the wheel was spun and magnitude dependent on the spin speed. There are three important advantages to the eccentrically loaded wheel: (1) it does not rely on force measurements made from other devices, (2) the tests require only 15 min to complete per force plate and (3) the forces exerted on the plate are similar to those of paediatric gait.

  6. Preliminary studies of microchannel plate photomultiplier tube neutron detectors for flight test applications

    International Nuclear Information System (INIS)

    Dolan, K.W.

    1978-10-01

    Electrical, mechanical, thermal, and neutron response data indicate that microchannel plate photomultiplier tubes are viable candidates as miniature, ruggedized neutron detectors for flight test applications in future weapon systems

  7. A crack arrest test using a toughness gradient steel plate

    International Nuclear Information System (INIS)

    Okamura, H.; Yagawa, G.; Urabe, Y.; Satoh, M.; Sano, J.

    1995-01-01

    Pressurized thermal shock (PTS) is a phenomenon that can occur in the reactor pressure vessels (RPVs) with internal pressure and is one of the most severe stress conditions that can be applied to the vessel. Preliminary research has shown that no PTS concern is likely to exist on Japanese RPVs during their design service lives. However, public acceptance of vessel integrity requires analyses and experiment in order to establish an analytical method and a database for life extension of Japanese RPVs. The Japanese PTS integrity study was carried out from FY 1983 to FY 1991 as a national project by Japan Power Engineering and Inspection Corporation (JAPEIC) under contract with Ministry of International Trade and Industry (MITI) in cooperation with LWR utilities and vendors. Here, a crack arrest test was carried out using a toughness gradient steel plate with three layers to study the concept of crack arrest toughness. Four-point bending load with thermal shock was applied to the large flat plate specimen with a surface crack. Five crack initiations and arrests were observed during the test and the propagated crack bifurcated. Finally, cracks were arrested at the boundary of the first and the second layer, except for a small segment of the crack. The first crack initiation took place slightly higher than the lower bound of K Ic data obtained by ITCT specimens. That is, the K IC concept for brittle crack initiation was verified for heavy section steel plates. The first crack arrest took place within the scatter band of K Ia and K Id data for the first layer. That is, the K Ia concept appears applicable for crack arrest of a short crack jump

  8. [Historical Development of the Wool and Colour Plate Tests for Screening for Colour Vision Deficiencies in German Speaking Countries].

    Science.gov (United States)

    Kuchenbecker, J

    2017-07-01

    Colour vision is a complex visual function that can be affected by congenital and/or acquired disorders. The frequency of congenital colour vision deficiencies has been investigated in rail and navy staff since the 1870s. Various test methods have been developed. Wool tests, flor contrast tests and colour plate tests have been used. A published colour plate test, based on Stilling's pseudo-isochromatic plates in combination with a flor contrast test, has been a common screening method for colour vision testing in German-speaking countries. This test is intended to detect congenital and acquired colour vision deficiencies in a simple and safe manner. More modern options, such as Internet and tablet PC have technical limitations, but will increasingly be used for screening for colour vision deficiencies. Georg Thieme Verlag KG Stuttgart · New York.

  9. A sperm-agglutinating lectin from seeds of Jack fruit (Artocarpus heterophyllus).

    Science.gov (United States)

    Namjuntra, P; Muanwongyathi, P; Chulavatnatol, M

    1985-04-30

    A lectin specific for N-acetylgalactosamine was isolated from seed extract of Jack fruit (Artocarpus heterophyllus) by ammonium sulfate precipitation, followed by affinity chromatography on a Affigel-galactosamine-agarose column. The lectin possessed agglutinating activities for human and rat sperm as well as human red blood cells. It was found to have Mr = 62,000 consisting of two dissimilar subunits of Mr = 18,000 and 13,000. It also cross-reacted with an antibody against the lectin of Osage Orange (Maclura pomifera).

  10. Evaluation of the Leptospira species microscopic agglutination test in experimentally vaccinated cats and Leptospira species seropositivity in aged azotemic client-owned cats.

    Science.gov (United States)

    Shropshire, Sarah B; Veir, Julia K; Morris, Arianne K; Lappin, Michael R

    2016-10-01

    The objectives of this study were to validate the microscopic agglutination test (MAT) using feline sera, determine cross-reactivity of Borrelia burgdorferi antibodies in the MAT, and evaluate if there is an association between Leptospira species seropositivity in aged (⩾10 years) client-owned cats with and without azotemia (creatinine >2 g/dl). A four-serovar canine leptospiral vaccine was administered to two specific pathogen-free (SPF) cats on days 0 and 14. The MAT was performed intermittently until day 42 for the serovars Canicola, Grippotyphosa, Hardjo, Icterohaemorrhagiae, Pomona and Bratislava, with a cut-off value of ⩾1:100. Five purpose-bred cats were infested with wild-caught Ixodes scapularis adults with an average B burgdorferi infection rate of 50%, and tested for antibodies against B burgdorferi C6 peptide and DNA in skin biopsies, as well as by MAT. Sera from 66 azotemic and 75 non-azotemic cats ⩾10 years of age were tested for Leptospira species antibodies using the MAT and results were compared by the χ(2) test. Both SPF cats seroconverted by week 3 and formed antibodies against at least one serovar. There was no cross-reactivity in the MAT using samples from cats with antibodies to B burgdorferi. MAT results were positive for 4/66 azotemic cats and 8/75 non-azotemic cats; these results were not statistically different. The MAT can be interpreted using feline serum and does not appear to cross-react in cats with B burgdorferi antibodies. There was no association between Leptospira species MAT results and azotemia in this group of aged client-owned cats but further studies are needed to determine if leptospirosis contributes to feline chronic kidney disease. © The Author(s) 2015.

  11. The Experiment Production And Examination Of The U3Si2-AI Mini plates For Irradiation Test

    International Nuclear Information System (INIS)

    Supardjo; Boybul; Yowono; Susworo; Permana, S.

    1998-01-01

    The fuel plates containing U 3 Si 2 -AI dispersion fuel having respective loading of 3.55; 4.20; and 4.80 g/cm 3 were prepared by dispersing certain amount of U 3 Si 2 powder in the AI powder as matrix. The weight ratio of U 3 Si 2 and AI at different loading was chosen based on the 19.23 cm 3 volume basis fuel core calculation. Each fuel mixture was pressed into a fuel core having dimension of 100.20 x 60.35 x 3.15 +- (0.05) mm, which was then cut into mini fuel core having dimension of 16 x 8 x 3.15 +- (0.05) mm. The mini plates were prepared by picture and frame technique using AIMg2 as cladding material. The mini plates have been tested for blister, homogeneity, white spots, surface defects and their cladding thickness, revealing that out of 74 mini plates, they are ten (10) mini plates that have to be rejected due to blisters and white spots, thus of 64 mini plates can be further fabricated as samples for irradiation test

  12. Improved Thermal-Vacuum Compatible Flat Plate Radiometric Source For System-Level Testing Of Optical Sensors

    Science.gov (United States)

    Schwarz, Mark A.; Kent, Craig J.; Bousquet, Robert; Brown, Steven W.

    2016-01-01

    In this work, we describe an improved thermal-vacuum compatible flat plate radiometric source which has been developed and utilized for the characterization and calibration of remote optical sensors. This source is unique in that it can be used in situ, in both ambient and thermal-vacuum environments, allowing it to follow the sensor throughout its testing cycle. The performance of the original flat plate radiometric source was presented at the 2009 SPIE1. Following the original efforts, design upgrades were incorporated into the source to improve both radiometric throughput and uniformity. The pre-thermal-vacuum (pre-TVAC) testing results of a spacecraft-level optical sensor with the improved flat plate illumination source, both in ambient and vacuum environments, are presented. We also briefly discuss potential FPI configuration changes in order to improve its radiometric performance.

  13. Topics in the Analysis of Shear-Wave Propagation in Oblique-Plate Impact Tests

    National Research Council Canada - National Science Library

    Scheidler, Mike

    2007-01-01

    This report addresses several topics in the theoretical analysis of shock waves, acceleration waves, and centered simple waves, with emphasis on the propagation of shear waves generated in oblique-plate impact tests...

  14. [Web-based analysis of Stilling's color plates].

    Science.gov (United States)

    Kuchenbecker, J

    2014-12-01

    Color vision tests with pseudoisochromatic plates currently represent the most common procedure for the screening of congenital color vision deficiencies. By means of a web-based color vision test, new and old color plates can be tested for diagnostic quality without major effort. A total of 16 digitized Stilling's color plates of the 11th edition from 1907 were included in a web-based color vision test (http://www.farbsehtest.de). The χ(2)-test was used to check whether the Stilling color plates showed similar results to the nine previously evaluated Ishihara color plates. A total of 518 subjects including101 (19.5 %) female subjects with a mean age of 34.6 ± 17 years, took the web-based test with the 25 plates. For all participants the range for the correctly recognized plates was between 5.2 % (n = 27) and 97.7 % (n = 506) for the Stilling color plates and between 64.9 % (n = 336) and 100 % (n = 518) for the Ishihara color plates. For participants with more than 5 errors (n = 247), the range for correctly recognized plates was between 2.0 % (n = 5) and 98.0 % (n = 242) for the Stilling plates and between 42.5 % (n = 105) and 100 % (n = 247) for the Ishihara plates. Taking all color plates and all participants into account there was a significantly higher incidence of erroneous recognition of the Stilling color plates (3038 false and 5250 true answers) compared to the Ishihara color plates (1511 false and 3151 true answers) (p plates could be used for the test edition of the Velhagen/Broschmann/Kuchenbecker color plates from 2014. Overall, the Stilling color plates were recognized with a higher incidence of error by all participants in the web-based test compared to the utilized Ishihara color plates, which in most cases was attributable to ambiguity of some symbols.

  15. Exploring new biological functions of amyloids: bacteria cell agglutination mediated by host protein aggregation.

    Directory of Open Access Journals (Sweden)

    Marc Torrent

    Full Text Available Antimicrobial proteins and peptides (AMPs are important effectors of the innate immune system that play a vital role in the prevention of infections. Recent advances have highlighted the similarity between AMPs and amyloid proteins. Using the Eosinophil Cationic Protein as a model, we have rationalized the structure-activity relationships between amyloid aggregation and antimicrobial activity. Our results show how protein aggregation can induce bacteria agglutination and cell death. Using confocal and total internal reflection fluorescence microscopy we have tracked the formation in situ of protein amyloid-like aggregates at the bacteria surface and on membrane models. In both cases, fibrillar aggregates able to bind to amyloid diagnostic dyes were detected. Additionally, a single point mutation (Ile13 to Ala can suppress the protein amyloid behavior, abolishing the agglutinating activity and impairing the antimicrobial action. The mutant is also defective in triggering both leakage and lipid vesicle aggregation. We conclude that ECP aggregation at the bacterial surface is essential for its cytotoxicity. Hence, we propose here a new prospective biological function for amyloid-like aggregates with potential biological relevance.

  16. Evaluation of two automated chemiluminescence immunoassays, the LIAISON Treponema Screen and the ARCHITECT Syphilis TP, and the Treponema pallidum particle agglutination test for laboratory diagnosis of syphilis.

    Science.gov (United States)

    Wellinghausen, Nele; Dietenberger, Hanna

    2011-08-01

    Automated Treponema pallidum-specific chemi-luminescence immunoassays (CLIA) run on random-access analyzers allow for rapid diagnosis of syphilis infection. We evaluated the LIAISON Treponema Screen (LIA) and the ARCHITECT Syphilis TP (ARCH) in comparison to the Treponema pallidum particle agglutination (TPPA) test, as a screening test for syphilis. We performed a prospective study using 577 sera submitted for diagnosis of syphilis, including 318 samples from pregnant women. In addition, 42 stored sera from 32 patients with clinically and serologically characterized syphilis infection were investigated. In the prospective study, the sensitivity and specificity of LIA, ARCH, and TPPA were 100% (18/18), 100% (17/17), and 100% (18/18), and 100% (558/558), 99.8% (552/553), and 99.6% (556/558), respectively. In pregnant women, the specificity of LIA and ARCH was 100% (317/317) and of TPPA 99.7% (316/317). One sample from a child with assumed exposure to maternal antitreponemal antibodies was omitted from analysis. LIA, ARCH, and TPPA were also positive in all investigated sera from patients with known syphilis. Both automated CLIA demonstrated excellent diagnostic sensitivity and specificity when evaluated as a screening test for syphilis under routine conditions of a diagnostic laboratory. Thus, these may be used independently as an alternative to the manual TPPA screen.

  17. Reliability and Lifetime Prediction of Remote Phosphor Plates in Solid-State Lighting Applications Using Accelerated Degradation Testing

    NARCIS (Netherlands)

    Yazdan Mehr, M.; van Driel, W.D.; Zhang, G.Q.

    2015-01-01

    A methodology, based on accelerated degradation testing, is developed to predict the lifetime of remote phosphor plates used in solid-state lighting (SSL) applications. Both thermal stress and light intensity are used to accelerate degradation reaction in remote phosphor plates. A reliability model,

  18. Basic performance tests on vibration of support structure with flexible plates for ITER tokamak device

    International Nuclear Information System (INIS)

    Takeda, Nobukazu; Kakudate, Satoshi; Shibanuma, Kiyoshi

    2005-01-01

    The vibration experiments of the support structures with flexible plates for the ITER major components such as toroidal field coil (TF coil) and vacuum vessel (VV) were performed using small-sized flexible plates aiming to obtain its basic mechanical characteristics such as dependence of the stiffness on the loading angle. The experimental results obtained by the hammering and frequency sweep tests were agreed each other, so that the experimental method is found to be reliable. In addition, the experimental results were compared with the analytical ones in order to estimate an adequate analytical model for ITER support structure with flexible plates. As a result, the bolt connection of the flexible plates on the base plate strongly affected on the stiffness of the flexible plates. After studies of modeling the bolts, it is found that the analytical results modeling the bolts with finite stiffness only in the axial direction and infinite stiffness in the other directions agree well with the experimental ones. Using this adequate model, the stiffness of the support structure with flexible plates for the ITER major components can be calculated precisely in order to estimate the dynamic behaviors such as eigen modes and amplitude of deformation of the major components of the ITER tokamak device. (author)

  19. Utilization of radiographic and ultrasonic testing for an evaluation of plate type fuel elements during manufacturing stages

    International Nuclear Information System (INIS)

    Brito, Mucio Jose Drummond de; Silva Junior, Silverio Ferreira da; Messias, Jose Marcos; Braga, Daniel Martins; Paula, Joao Bosco de

    2005-01-01

    Structural discontinuities can be introduced in the plate type fuel elements during the manufacturing stages due to mechanical processing conditions. The use of nondestructive testing methods to monitoring the fuel elements during the manufacturing stages presents a significant importance, contributing for manufacturing process improvement and cost reducing. This paper describes a procedure to be used detection and evaluation of structural discontinuities in plate type fuel elements during the manufacturing stages using the ultrasonic testing method and the radiographic testing method. The main results obtained are presented and discussed. (author)

  20. Concrete containment tests: Phase 2, Structural elements with liner plates: Interim report

    International Nuclear Information System (INIS)

    Hanson, N.W.; Roller, J.J.; Schultz, D.M.; Julien, J.T.; Weinmann, T.L.

    1987-08-01

    The tests described in this report are part of Phase 2 of the Electric Power Research Institute (EPRI) program. The overall objective of the EPRI program is to provide a test-verified analytical method of estimating capacities of concrete reactor containment buildings under internal overpressurization from postulated degraded core accidents. The Phase 2 testing included seven large-scale specimens representing structural elements from reinforced and prestressed concrete reactor containment buildings. Six of the seven test specimens were square wall elements. Of these six specimens, four were used for biaxial tension tests to determine strength, deformation, and leak-rate characteristics of full-scale wall elements representing prestressed concrete containment design. The remaining two square wall elements were used for thermal buckling tests to determine whether buckling of the steel liner plate would occur between anchorages when subjected to a sudden extreme temperature differential. The last of the seven test specimens for Phase 2 represented the region where the wall and the basemat intersect in a prestressed concrete containment building. A multi-directional loading scheme was used to produce high bending moments and shear in the wall/basemat junction region. The objective of this test was to determine if there is potential for liner plate tearing in the junction region. Results presented include observed behavior and extensive measurements of deformations and strains as a function of applied load. The data are being used to confirm analytical models for predicting strength and deformation of containment structures in a separate parallel analytical investigation sponsored by EPRI

  1. Latex agglutination test

    Science.gov (United States)

    ... Updated by: Frank A. Greco, MD, PhD, Director, Biophysical Laboratory, Edith Nourse Rogers Memorial Hospital, Bedford, MA. ... any medical emergency or for the diagnosis or treatment of any medical condition. A licensed physician should ...

  2. Cadmium plating replacements

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, M.J.; Groshart, E.C.

    1995-03-01

    The Boeing Company has been searching for replacements to cadmium plate. Two alloy plating systems seem close to meeting the needs of a cadmium replacement. The two alloys, zinc-nickel and tin-zinc are from alloy plating baths; both baths are neutral pH. The alloys meet the requirements for salt fog corrosion resistance, and both alloys excel as a paint base. Currently, tests are being performed on standard fasteners to compare zinc-nickel and tin-zinc on threaded hardware where cadmium is heavily used. The Hydrogen embrittlement propensity of the zinc-nickel bath has been tested, and just beginning for the tin-zinc bath. Another area of interest is the electrical properties on aluminum for tin-zinc and will be discussed. The zinc-nickel alloy plating bath is in production in Boeing Commercial Airplane Group for non-critical low strength steels. The outlook is promising that these two coatings will help The Boeing Company significantly reduce its dependence on cadmium plating.

  3. A reciprocating pin-on-plate test-rig for studying friction materials for holding brakes

    DEFF Research Database (Denmark)

    Poulios, Konstantinos; Drago, Nicola; Klit, Peder

    2014-01-01

    -on-plate test-rig for studying the evolution of wear by monitoring the pin height reduction using Eddy-current proximity sensors is presented. Moreover, a new mechanism for recording the friction force is suggested. Apart from the design of the test-rig, friction force and wear rate measurements for two...

  4. Características físicas de dietas para peixes confeccionadas com diferentes aglutinantes Influence of agglutinants on physical stability of fish diets

    Directory of Open Access Journals (Sweden)

    Margarida Maria Barros

    2002-04-01

    Full Text Available Este experimento teve por objetivo avaliar a eficiência de diferentes aglutinantes, a seco e na água, por meio da estabilidade física do pélete. Foram avaliadas duas técnicas de processamento (com ou sem vapor e seis aglutinantes (carboximetilcelulose, polimetilcarbamida, amido de mandioca, alginato de sódio, polivinilpirrolidona, goma guar, através da análise de variância no esquema fatorial (2x6, além de um controle, ao qual não foi acrescido aglutinante. Concluiu-se que o aglutinante melhora significativamente a resistência física do grânulo, independente da técnica de processamento; que o vapor determina grânulos mais estáveis quando em contato com a água e, que o alginato de sódio proporciona grânulos fisicamente mais estáveis, em ambas as técnicas de processamento, enquanto a goma guar a pior.The aim of this paper was to determine the influence of different dry and water agglutinants, through physical stability of pellets. The agglutinants were sodium alginate, guar gum, polymetylcarbamide, polyvinylpirrolidone, carboxymetilcellulose, and cassava starch. The manufacturing processes were two: with and without steam and extrusion. These treatments were evaluated through the variance analysis technique with the factorial scheme 2 x 6 (two processes and six agglutinants, and one control where no extra agglutinants was added. Results showed that, independently of processing technique, the presence the agglutinants improves the physical resistance of the pellets significantly, giving the whole pellets more stability while in contact with water, and that the sodium alginate gives pellets the highest aggregated characteristic, in both processes, while that guar gum gives the lowest.

  5. Examinations of the irradiation behaviour of U3Si2 test fuel plates with low enrichment

    International Nuclear Information System (INIS)

    Muellauer, J.

    1989-01-01

    Five low-enriched (19.7% 235 U), high-density (4.7 gU/cm/ 3 ) U 3 Si 2 -test fuel plates (miniplates) with different fine grain contents have been qualified under irradiation. During the course of irradiation up to burnup of 63% 235 U depletion, no released fractions of gaseous or solid fission products from the fuel plate to the rig coolant were detected. The measured swelling rate of the fuel zone (meat) is less than 0.45% ΔV/10 20 fissions/cm 3 the blister-threshold temperature of the fuel plates is above 520 0 C. The favourable irradiation behavior of the U 3 Si 2 fuel plates was not influenced by using higher amounts of fine grained particles (40% [de

  6. Ricinus communis agglutinin-mediated agglutination and fusion of glycolipid-containing phospholipid vesicles: effect of carbohydrate head group size, calcium ions, and spermine.

    Science.gov (United States)

    Hoekstra, D; Düzgüneş, N

    1986-03-25

    The glycolipids galactosylcerebroside (GalCer), lactosylceramide (LacCer), and trihexosylceramide (Gb3) were inserted into phospholipid vesicles, consisting of phosphatidylethanolamine and phosphatidic acid. The extent to which their carbohydrate head groups protruded beyond the vesicle surface and their interference with membrane approach were examined by determining vesicle susceptibility toward type I Ricinus communis agglutinin (RCA1) induced agglutination and Ca2+- and spermine-induced aggregation and fusion either in the presence or in the absence of the lectin. The initial agglutination rates increased in the order GalCer much less than LacCer less than Gb3, while a reversed order was obtained for Ca2+- and spermine-induced aggregation and fusion, indicating an enhanced steric interference on close approach of bilayers with increasing head group size. The lectin-mediated agglutination rates for LacCer- and Gb3-containing vesicles increased by an order of magnitude when Ca2+ was also included in the medium, at a concentration that did not induce aggregation per se. Charge neutralization could not account for this observation as the polyvalent cation spermine did not display this synergistic effect with RCA1. Addition of Ca2+ to preagglutinated vesicles substantially reduced the threshold cation concentration for fusion (micromolar vs. millimolar). Quantitatively, this concentration decreased with decreasing carbohydrate head group size, indicating that the head group protrusion determined the interbilayer distance within the vesicle aggregate. The distinct behavior of Ca2+ vs. spermine on RCA1-induced agglutination on the one hand and fusion on the other indicated that Ca2+ regulates the steric orientation of the carbohydrate head group, which appears to be related to its ability to dehydrate the bilayer. As a result, lectin agglutinability becomes enhanced while fusion will be interrupted as the interbilayer distance increases, the threshold head group size

  7. Serological prevalence and associated risk factors of Salmonella ...

    African Journals Online (AJOL)

    ... to identify risk factors associated with Salmonella infections in chickens. The overall sero-prevalence established using serum plate agglutination test was 16.7% (98/588). Using a univariate logistic analysis, factors significantly associated with Salmonella infections at p < 0.05 were presence of other birds in poultry farms ...

  8. Lab-on-a-disc agglutination assay for protein detection by optomagnetic readout and optical imaging using nano- and micro-sized magnetic beads

    DEFF Research Database (Denmark)

    Uddin, Rokon; Burger, Robert; Donolato, Marco

    2016-01-01

    of manual steps involved. The detection of the target protein was achieved in two ways: (1) optomagnetic readout using magnetic nanobeads (MNBs); (2) optical imaging using magnetic microbeads (MMBs). The optomagnetic readout of agglutination is based on optical measurement of the dynamics of MNB aggregates...... whereas the imaging method is based on direct visualization and quantification of the average size of MMB aggregates. By enhancing magnetic particle agglutination via application of strong magnetic field pulses, we obtained identical limits of detection of 25 pM with the same sample-to-answer time (15 min...

  9. Destructive examination of test plates 3 and test piece 4 of the defects detection trials (DDT)

    International Nuclear Information System (INIS)

    Buegers, W.; Crutzen, S.; Pisoni, A.; Violin, F.; Di Piazza, L.; Lock, D.; Sargent, T.

    1984-01-01

    The evaluation of NDT exercises results has been based on destructive examination of the plates or test blocks used during the exercise. The PISC I Programme has shown that in all cases the indications given by the NDT instrumentation were corresponding to some particular defects or structure aspects in the steel or were explained by particular positions of reflectors. Generally the introduction of defects using techniques such as: - implantation of modules, - introduction of non metallic material, - introduction of poison in the weld, do not produce a final ''detective zone or area'' which is strictly corresponding to the intended defect. The DDT exercise management has thus decided to perform a complete destructive examination of the four plates involved in this exercise because of its experience (the PISC I exercise) and independance of commercial interest, the JRC of the CEC, Ispra Establishment, has been asked to do the work in collaboratione with the Risley Nuclear Power development Laboratories (RNL). A collaboration agreement has been signed between RNL and JRC. Operating Agent of the PISC II programme, is interested in having a direct access to data to be added to those furnished by PISC. The present report describes the results of the destructive examination of the DDT plates 3 and 4

  10. Design, construction and testing of a low-cost flat plate solar energy ...

    African Journals Online (AJOL)

    A low-cost flat plate solar energy collector has been designed and constructed with locally available materials such as mild steel and black paint of absorptance 0.94. On testing, an average daily efficiency of 55.6% was obtained. The methods are simple and illustrate the fact that construction of efficient collectors are ...

  11. Low upper-shelf toughness, high transition temperature test insert in HSST [Heavy Section Steel Technology] PTSE-2 [Pressurized Thermal Shock Experiment-2] vessel and wide plate test specimens: Final report

    International Nuclear Information System (INIS)

    Domian, H.A.

    1987-02-01

    A piece of A387, Grade 22 Class 2 (2-1/4 Cr - 1 Mo) steel plate specially heat treated to produce low upper-shelf (LUS) toughness and high transition temperature was installed in the side wall of Heavy Section Steel Technology (HHST) vessel V-8. This vessel is to be tested by the Oak Ridge National Laboratory (ORNL) in the Pressurized Thermal Shock Experiment-2 (PTSE-2) project of the HSST program. Comparable pieces of the plate were made into six wide plate specimens and other samples. These samples underwent tensile tests, Charpy tests, and J-integral tests. The results of these tests are given in this report

  12. Destructive examination of test plates 1 and 2 of the defects detection trials

    International Nuclear Information System (INIS)

    Crutzen, S.; Buergers, W.; Violin, F.; Di Piazza, L.; Cowburn, K.; Sargent, T.

    1983-01-01

    A further phase of the UKAEA defect detection trials (described previously) with PWR pressure vessel steels is reported. The evaluation of NDT exercise results must be based on destructive examination of the plates used during the exercise. Tests are described and results given. (U.K.)

  13. Standard Test Method for Mechanical Hydrogen Embrittlement Evaluation of Plating/Coating Processes and Service Environments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method describes mechanical test methods and defines acceptance criteria for coating and plating processes that can cause hydrogen embrittlement in steels. Subsequent exposure to chemicals encountered in service environments, such as fluids, cleaning treatments or maintenance chemicals that come in contact with the plated/coated or bare surface of the steel, can also be evaluated. 1.2 This test method is not intended to measure the relative susceptibility of different steels. The relative susceptibility of different materials to hydrogen embrittlement may be determined in accordance with Test Method F1459 and Test Method F1624. 1.3 This test method specifies the use of air melted AISI E4340 steel per SAE AMS-S-5000 (formerly MIL-S-5000) heat treated to 260 – 280 ksi (pounds per square inch x 1000) as the baseline. This combination of alloy and heat treat level has been used for many years and a large database has been accumulated in the aerospace industry on its specific response to exposure...

  14. Laterally Loaded Nail-Plates

    DEFF Research Database (Denmark)

    Nielsen, Jacob; Rathkjen, Arne

    Load-displacement curves from about 200 short-term and laterally loaded nail-plate joints are analysed. The nail-plates are from Gang-Nail Systems, type GNA 20 S. The test specimens and the measuring systems are described. The tests are divided into 32 different series. The influence of the number...

  15. Evaluation of the antinociceptive activities of enaminone compounds on the formalin and hot plate tests in mice

    Science.gov (United States)

    Masocha, Willias; Kombian, Samuel B.; Edafiogho, Ivan O.

    2016-02-01

    Recently, we found that methyl 4-(4‧-bromophenyl)aminocyclohex-3-en-6-methyl-2-oxo-1-oate (E139), an anticonvulsant enaminone, has antinociceptive activity in the hot plate test. In this study we evaluated the antinociceptive activity of five anilino enaminones E139, ethyl 4-(4‧-chlorophenyl)amino-6-methyl-2-oxocyclohex-3-en-1-oate (E121), ethyl 4-(4‧-bromophenyl)amino-6-methyl-2-oxocyclohex-3-en-1-oate (E122), methyl 4-(4‧-chlorophenyl)amino-6-methyl-2-oxocyclohex-3-en-1-oate (E138) and ethyl 4-(4‧-fluorophenyl)amino-6-methyl-2-oxocyclohex-3-en-1-oate (BRG 19) using the formalin and hot plate tests. E139 has been reported to exert its effects via enhancement of extracellular GABA levels, thus tiagabine, a GABA transporter inhibitor, was evaluated as a control together with indomethacin. Tiagabine had antinociceptive activity in both phase 1 (neurogenic pain) and phase 2 (inflammatory pain) of the formalin test, whereas indomethacin had activity only in phase 2. E139 and E138 had antinociceptive activity in both phases of the formalin test, whereas E121 had activity only in phase 1 and BRG 19 had activity only in phase 2. E122 had no significant activity in either phase. In the hot plate test only E139 had antinociceptive activity. Administration of either bicuculline, a GABAA receptor antagonist, or CGP 35348, a GABAB receptor antagonist, blocked the antinociceptive activity of E139. In conclusion our results indicate that E139 has antinociceptive activity in the formalin and hot plate tests that are dependent on GABA receptors.

  16. Comparison of the results of wide plate tests with the predictions of several fracture concepts

    International Nuclear Information System (INIS)

    Rosezin, H.J.; Dahl, W.

    1985-01-01

    With the results of wide plate tests on center cracked specimens the concept of the plastic limit load, the Burdekin-Dawes-design-concept, the J-design-curve according to Turner, the estimation proceeding according to Shih and Kumar, the Two-Criteria-Approach and the FAD according to Pellini were examined and the limits of their application exhibited. The maximum loads of wide plate specimens can be estimated by the plastic limit load, if no low-stress-fractures occur. Corresponding to the Pellini-concept no low-stress-fractures occured at test temperatures above NDT, if the NDT-temperature of the region of material was used, in which the crack was located. With the concept according to Shih and Kumar an estimation of the instability loads of wide plate specimens is possible, if the fracture behaviour is fully ductile, but not in all cases conservative predictions were made. A prediction of critical stresses and crack sizes is possible with the other concepts examined, if the evaluations are based on the critical values for the onset of stable or unstable crack growth. (orig.) [de

  17. Ni-based amorphous alloy-coating for bipolar plate of PEM fuel cell by electrochemical plating

    International Nuclear Information System (INIS)

    Yamaura, S; Kim, S C; Inoue, A

    2013-01-01

    In this study, the Ni-Cr-P amorphous alloy-coated bipolar plates were produced by electro-plating on the Cu base plates with a flow field. The power generation tests of a single fuel cell with those Ni-Cr-P bipolar plates were conducted at 353 K. It was found that the single fuel cell with those Ni-Cr-P bipolar plates showed excellent I-V performance as well as that with the carbon graphite bipolar plates. It was also found that the single cell with those Ni-Cr-P bipolar plates showed better I-V performance than that with the Ni-P amorphous alloy-coated bipolar plates. Furthermore, the long-time operation test was conducted for 440 h with those Ni-Cr-P bipolar plates at the constant current density of 200 mA·cm −2 . As a result, it was found that the cell voltage gradually decreased at the beginning of the measurement before 300 h and then the voltage was kept constant after 300 h.

  18. Laboratory evaluation of a simple and rapid latex agglutination assay for the serodiagnosis of typhoid fever

    NARCIS (Netherlands)

    Abdoel, Theresia H.; Pastoor, Rob; Smits, Henk L.; Hatta, Mochammad

    2007-01-01

    A latex agglutination assay for the serodiagnosis of typhoid fever was evaluated on samples collected from patients with clinical suspicion of typhoid fever in South Sulawesi, Indonesia, where the disease is endemic. The latex assay is very easy to use, gives a rapid result and may be used as a

  19. Uncertainty evaluation in the self-alignment test of the upper plate of a press

    International Nuclear Information System (INIS)

    Lourenço, Alexandre S; E Sousa, J Alves

    2015-01-01

    This paper describes a method to evaluate uncertainty of the self-alignment test of the upper plate of a press according to EN 12390-4:2000. The method, the algorithms and the sources of uncertainty are described

  20. Three-beam interferogram analysis method for surface flatness testing of glass plates and wedges

    Science.gov (United States)

    Sunderland, Zofia; Patorski, Krzysztof

    2015-09-01

    When testing transparent plates with high quality flat surfaces and a small angle between them the three-beam interference phenomenon is observed. Since the reference beam and the object beams reflected from both the front and back surface of a sample are detected, the recorded intensity distribution may be regarded as a sum of three fringe patterns. Images of that type cannot be succesfully analyzed with standard interferogram analysis methods. They contain, however, useful information on the tested plate surface flatness and its optical thickness variations. Several methods were elaborated to decode the plate parameters. Our technique represents a competitive solution which allows for retrieval of phase components of the three-beam interferogram. It requires recording two images: a three-beam interferogram and the two-beam one with the reference beam blocked. Mutually subtracting these images leads to the intensity distribution which, under some assumptions, provides access to the two component fringe sets which encode surfaces flatness. At various stages of processing we take advantage of nonlinear operations as well as single-frame interferogram analysis methods. Two-dimensional continuous wavelet transform (2D CWT) is used to separate a particular fringe family from the overall interferogram intensity distribution as well as to estimate the phase distribution from a pattern. We distinguish two processing paths depending on the relative density of fringe sets which is connected with geometry of a sample and optical setup. The proposed method is tested on simulated data.

  1. Resistive Plate Chamber Performance During the CMS Magnet Test Cosmic Challenge

    CERN Document Server

    Trentadue, R

    2008-01-01

    The CMS detector at the CERN Large Hadron Collider (LHC) is equipped with a redundant muon system based on Drift Tubes Chambers (barrel region) and Cathode Strip Chamber (endcap region), and Resistive Plate Chamber (RPC). During the summer and fall 2006 a first integrated test of an entire CMS slice was performed at the SX5 experimental surface hall. The RPC chambers were operated with cosmic rays. The results on the RPC performance are reported.

  2. Feasibility of Electromagnetic Acoustic Evaluation for Quality Test of a Plate-type Nuclear Fuel

    International Nuclear Information System (INIS)

    Jung, Hyun Kyu; Lee, Yoon Sang; Cheong, Yong Moo

    2010-01-01

    Most research and test reactors use the nuclear fuel plates which are consisted of a fuel core in aluminum alloy. Recently KAERI signed a deal with the Jordan Atomic Energy Commission to build the research reactor and have to supply the plate-type nuclear fuels. For the demands of world market, KAERI started the research and development of the plate-type fuel elements and endeavored to achieve a localization of fuel fabrication. For the inspection of plate-type fuel elements to be used in Research Reactors, an immersion pulse-echo ultrasonic technique was applied. This inspection was done with water, so a nuclear fuel was immersed to be prone to corrosion and needed to have time and cost due to an additional process. The sample that will be examined within this paper is a non-ferromagnetic material such as aluminum which has a good acousto-elastic property, for an effective inspection of a bond quality for a nuclear fuel under a manufacturing environment. The purpose of this study is to investigate the feasibility of an EMAT technology for an automated inspection of a nuclear fuel without water

  3. Plate fixation in periprosthetic femur fractures Vancouver type B1-Trochanteric hook plate or subtrochanterical bicortical locking?

    Science.gov (United States)

    Lenz, Mark; Stoffel, Karl; Kielstein, Heike; Mayo, Keith; Hofmann, Gunther O; Gueorguiev, Boyko

    2016-12-01

    Proximal plate fixation in periprosthetic femur fractures can be improved by plate anchorage in the greater trochanter (lateral tension band principle) or bicortical locking screw placement beside the prosthesis stem in an embracement configuration. Both concepts were compared in a biomechanical test using a femoral hook plate (hook) or a locking attachment plate (LAP). After bone mineral density (BMD) measurement in the greater trochanter, six pairs of fresh frozen human femora were assigned to two groups and instrumented with cemented hip endoprostheses. A transverse osteotomy was set distal to the tip of the prosthesis, simulating a Vancouver B1 fracture. Each pair was instrumented using a plate tensioner with either hook or LAP construct. Cyclic testing (2Hz) with physiologic profile and monotonically increasing load was performed until catastrophic failure. Plate stiffness was compared in a four-point-bending-test. Paired student's-t-test was used for statistical evaluation (pTrochanteric fixation is highly BMD dependent and may be restricted to major greater trochanteric involvement requiring stabilization. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Evaluation of the Widal tube agglutination test for the diagnosis of typhoid fever among children admitted to a rural hdospital in Tanzania and a comparison with previous studies

    Directory of Open Access Journals (Sweden)

    Malahiyo Rajabu

    2010-06-01

    Full Text Available Abstract Background The diagnosis of typhoid fever is confirmed by culture of Salmonella enterica serotype Typhi (S. typhi. However, a more rapid, simpler, and cheaper diagnostic method would be very useful especially in developing countries. The Widal test is widely used in Africa but little information exists about its reliability. Methods We assessed the performance of the Widal tube agglutination test among febrile hospitalized Tanzanian children. We calculated the sensitivity, specificity, positive predictive value (PPV, and negative predictive value (NPV of various anti-TH and -TO titers using culture-confirmed typhoid fever cases as the "true positives" and all other febrile children with blood culture negative for S. typhi as the "true negatives." Results We found that 16 (1% of 1,680 children had culture-proven typhoid fever. A single anti-TH titer of 1:80 and higher was the optimal indicator of typhoid fever. This had a sensitivity of 75%, specificity of 98%, NPV of 100%, but PPV was only 26%. We compared our main findings with those from previous studies. Conclusion Among febrile hospitalized Tanzanian children with a low prevalence of typhoid fever, a Widal titer of ≥ 1:80 performed well in terms of sensitivity, specificity, and NPV. However a test with improved PPV that is similarly easy to apply and cost-efficient is desirable.

  5. Locking screw-plate interface stability in carbon-fibre reinforced polyetheretherketone proximal humerus plates.

    Science.gov (United States)

    Hak, David J; Fader, Ryan; Baldini, Todd; Chadayammuri, Vivek B S

    2017-09-01

    Carbon-fibre reinforced polyetheretherketone (CFR-PEEK) plates have recently been introduced for proximal humerus fracture treatment. The purpose of this study was to compare the locking screw-plate interface stability in CFR-PEEK versus stainless steel (SS) proximal humerus plates. Locking screw mechanical stability was evaluated independently in proximal and shaft plate holes. Stiffness and load to failure were tested for three conditions: (1) on-axis locking screw insertion in CFR-PEEK versus SS plates, (2) on-axis locking screw insertion, removal, and reinsertion in CFR-PEEK plates, and (3) 10-degree off-axis locking screw insertion in CFR-PEEK plates. Cantilever bending at a rate of 1 mm/minute was produced by an Instron machine and load-displacement data recorded. Shaft locking screw load to failure was significantly greater in CFR-PEEK plates compared to SS plates (746.4 ± 89.7 N versus 596.5 ± 32.6 N, p PEEK plates (p PEEK plates. The mechanical stability of locking screws in CFR-PEEK plates is comparable or superior to locking screws in SS plates.

  6. Development of a rapid agglutination latex test for diagnosis of enteropathogenic and enterohemorrhagic Escherichia coli infection in developing world: defining the biomarker, antibody and method.

    Directory of Open Access Journals (Sweden)

    Letícia B Rocha

    2014-09-01

    Full Text Available Enteropathogenic and enterohemorrhagic Escherichia coli (EPEC/EHEC are human intestinal pathogens responsible for diarrhea in both developing and industrialized countries. In research laboratories, EPEC and EHEC are defined on the basis of their pathogenic features; nevertheless, their identification in routine laboratories is expensive and laborious. Therefore, the aim of the present work was to develop a rapid and simple assay for EPEC/EHEC detection. Accordingly, the EPEC/EHEC-secreted proteins EspA and EspB were chosen as target antigens.First, we investigated the ideal conditions for EspA/EspB production/secretion by ELISA in a collection of EPEC/EHEC strains after cultivating bacterial isolates in Dulbecco's modified Eagle's medium (DMEM or DMEM containing 1% tryptone or HEp-2 cells-preconditioned DMEM, employing either anti-EspA/anti-EspB polyclonal or monoclonal antibodies developed and characterized herein. Subsequently, a rapid agglutination latex test (RALT was developed and tested with the same collection of bacterial isolates.EspB was defined as a biomarker and its corresponding monoclonal antibody as the tool for EPEC/EHEC diagnosis; the production of EspB was better in DMEM medium. RALT assay has the sensitivity and specificity required for high-impact diagnosis of neglected diseases in the developing world.RALT assay described herein can be considered an alternative assay for diarrhea diagnosis in low-income countries since it achieved 97% sensitivity, 98% specificity and 97% efficiency.

  7. Destructive examination of test plates 1 and 2 of the defects detection trials (DDT)

    International Nuclear Information System (INIS)

    Crutzen, S.; Buegers, W.; Violin, F.; Di Piazza, L.; Cowburn, K.; Sargent, T.

    1984-01-01

    The evaluation of NDT exercises results has been based on destructive examination of the plates or test blocks used during the exercise. The PISC Programme has shown that in all cases the indications given by the NDT instrumentation were corresponding to some particular defects or structure aspects in the steel or were explained by particular positions of reflectors. Generally the introduction of defects do not produce a final ''defective zone or area'' which is strictly corresponding to the intended defect. The DDT exercise management has thus decided to perform a complete destructive examination of the four plates involved in this exercise because of its experience (the PISC I exercise) and independance of commercial interest, the JRC of the CEC Ispra Establishment has been asked to do the work with the Risley Nuclear Power Development Laboratories (RNL). The present report describes the results of the destructive examination of the DDT plates 1 and 2

  8. Fabrication and testing of U–7Mo monolithic plate fuel with Zircaloy cladding

    Energy Technology Data Exchange (ETDEWEB)

    Pasqualini, E.E. [Laboratorio de Nanotecnología Nuclear, Centro Atómico Constituyentes, Comisión Nacional de Energía Atómica, Av. General Paz 1499, B1650KNA, San Martín, Prov. Buenos Aires (Argentina); Robinson, A.B. [Idaho National Laboratory, P. O. Box 1625, Idaho Falls, ID, 83415-6188 (United States); Porter, D.L., E-mail: Douglas.Porter@inl.gov [Idaho National Laboratory, P. O. Box 1625, Idaho Falls, ID, 83415-6188 (United States); Wachs, D.M. [Idaho National Laboratory, P. O. Box 1625, Idaho Falls, ID, 83415-6188 (United States); Finlay, M.R. [Australian Nuclear Science and Technology Organisation, PMB 1, Menai, NSW, 2234 (Australia)

    2016-10-15

    Nuclear fuel designs are being developed to replace highly enriched fuel used in research and test reactors with fuels of low enrichment. In the most challenging cases, U–(7–10 wt%)Mo monolithic plate fuels are proposed. One of the considered designs includes aluminum-alloy cladding, which provides some challenges in fabrication and fuel/cladding interaction during service. Zircaloy cladding, specifically Zry–4, was investigated as an alternative cladding, and development of a fabrication method was performed by researchers with the Comisión Nacionalde Energia Atómica (CNEA) in Argentina, resulting in test fuel plates (Zry–4 clad U–7Mo) which were subsequently tested in the Advanced Test Reactor in Idaho. Because Zry–4 and U–(7–10)Mo have similar high-temperature mechanical properties, fabrication was simplified in that the fuel foil and cladding could be co-rolled and bonded. The challenge was to prevent a thermal-expansion mismatch, which could destroy the fuel/cladding bond before complete bonding was achieved; the solution was to prevent the composites from cooling significantly during or between roll passes. The final product performed very well in-reactor, showing good bonding, very little fuel/cladding interaction—either from fabrication or in-reactor testing—and little swelling, especially no detectable heterogeneous bubble formation at the fuel/cladding interface tested to a fission density of up to 2.7E+21 (average) fissions/cm{sup 3}, 3.8E+21 (peak).

  9. C6 plate puncture testing report.

    Energy Technology Data Exchange (ETDEWEB)

    Vangoethem, Douglas J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Cordova, Theresa Elena [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Reu, Phillip L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2013-04-01

    There are numerous scenarios where critical systems could be subject to penetration by projectiles or fixed objects (e.g., collision, natural disaster, act of terrorism, etc.). It is desired to use computational models to examine these scenarios and make risk-informed decisions; however, modeling of material failure is an active area of research, and new models must be validated with experimental data. The purpose of this report is to document the experimental work performed from FY07 through FY08 on the Campaign Six Plate Puncture project. The goal of this project was to acquire experimental data on the puncture and penetration of metal plates for use in model validation. Of particular interest is the PLH failure model also known as the multilinear line segment model. A significant amount of data that will be useful for the verification and validation of computational models of ductile failure were collected during this project were collected and documented herein; however, much more work remains to be performed, collecting additional experimental data that will further the task of model verification.

  10. Systematic test on fast time resolution parallel plate avalanche counter

    International Nuclear Information System (INIS)

    Chen Yu; Li Guangwu; Gu Xianbao; Chen Yanchao; Zhang Gang; Zhang Wenhui; Yan Guohong

    2011-01-01

    Systematic test on each detect unit of parallel plate avalanche counter (PPAC) used in the fission multi-parameter measurement was performed with a 241 Am α source to get the time resolution and position resolution. The detectors work at 600 Pa flowing isobutane and with-600 V on cathode. The time resolution was got by TOF method and the position resolution was got by delay line method. The time resolution of detect units is better than 400 ps, and the position resolution is 6 mm. The results show that the demand of measurement is fully covered. (authors)

  11. Laboratory evaluation of 3M Petrifilms and University of Minnesota Bi-plates as potential on-farm tests for clinical mastitis.

    Science.gov (United States)

    McCarron, J L; Keefe, G P; McKenna, S L B; Dohoo, I R; Poole, D E

    2009-05-01

    The objective was to determine test characteristics and compare 2 potential on-farm culture systems for clinical mastitis, the Minnesota Easy Culture System II Bi-plate and Petrifilm. The tests were evaluated using clinically positive mastitic milk samples (n = 282) to determine their ability to differentiate appropriate treatment groups; all cases that had gram-positive growth were considered treatment candidates (n = 161), whereas cases that grew gram-negative organisms only or yielded no bacterial growth were classified as no treatment (n = 121). For Petrifilm, both undiluted and 1:10 diluted milk samples were used. To create treatment categories, 2 types of Petrifilms were used, Aerobic Count (AC) and Coliform Count (CC). Both Bi-plates and Petrifilms were read after 24 h of incubation. Analysis was conducted at various colony count thresholds for the Petrifilm test system. The combination of Petrifilms that had the highest sensitivity classified a case as gram-negative if there were > or =20 colonies present on the CC. If there were 5 colonies present on the AC, a case would be classified as gram-positive. The Bi-plate had a sensitivity of 97.9% and a specificity of 68.6%. The Petrifilm test system had a sensitivity of 93.8% and a specificity of 70.1%. There was no significant difference in the sensitivities between the tests. All Bi-plates and Petrifilms were read by a laboratory technician and a group of masked readers with limited microbiology training. Kappa values for the masked readers were 0.75 for Bi-plates and 0.84 and 0.86 for AC and CC Petrifilms, respectively. The Bi-plate and Petrifilm were able to successfully categorize clinical cases of mastitis into 2 treatments based on their ability to detect the presence of a gram-positive organism. Neither method had the ability to determine if a sample was contaminated. The results of this study indicate that both tests were able to appropriately categorize cases, which could potentially result in a

  12. CAD-CAM plates versus conventional fixation plates for primary mandibular reconstruction: A biomechanical in vitro analysis.

    Science.gov (United States)

    Rendenbach, Carsten; Sellenschloh, Kay; Gerbig, Lucca; Morlock, Michael M; Beck-Broichsitter, Benedicta; Smeets, Ralf; Heiland, Max; Huber, Gerd; Hanken, Henning

    2017-11-01

    CAD/CAM reconstruction plates have become a viable option for mandible reconstruction. The aim of this study was to determine whether CAD/CAM plates provide higher fatigue strength compared with conventional fixation systems. 1.0 mm miniplates, 2.0 mm conventional locking plates (DePuy Synthes, Umkirch, Germany), and 2.0 mm CAD/CAM plates (Materialise, Leuven, Belgium/DePuy Synthes) were used to reconstruct a polyurethane mandible model (Synbone, Malans, CH) with cortical and cancellous bone equivalents. Mastication was simulated via cyclic dynamic testing using a universal testing machine (MTS, Bionix, Eden Prairie, MN, USA) until material failure reached a rate of 1 Hz with increasing loads on the left side. No significant difference was found between the groups until a load of 300 N. At higher loads, vertical displacement differed increasingly, with a poorer performance of miniplates (p = 0.04). Plate breakage occurred in miniplates and conventional locking plates. Screw breakage was recorded as the primary failure mechanism in CAD/CAM plates. Stiffness was significantly higher with the CAD/CAM plates (p = 0.04). CAD/CAM plates and reconstruction plates provide higher fatigue strength than miniplates, and stiffness is highest in CAD/CAM systems. All tested fixation methods seem sufficiently stable for mandible reconstruction. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Effects of rest time after Li plating on safety behavior—ARC tests with commercial high-energy 18650 Li-ion cells

    International Nuclear Information System (INIS)

    Waldmann, Thomas; Wohlfahrt-Mehrens, Margret

    2017-01-01

    During charging at low temperatures, metallic Lithium can be deposited on the surface of graphite anodes of Li-ion cells. This Li plating does not only lead to fast capacity fade, it can also impair the safety behavior. The present study observes the effect of rest periods between Li plating and subsequent accelerated rate calorimetry (ARC) tests. As an example, commercial 3.25 Ah 18650-type cells with graphite anodes and NCA cathodes are cycled at 0 °C to provoke Li plating. It is found that the rest period at 25 °C between Li plating and the ARC tests has a significant influence on the onset temperature of exothermic reactions (T SH ), the onset temperature of thermal runaway (T TR ), the maximum temperature, the self-heating rate, and on damage patterns of 18650 cells. The results are discussed in terms of chemical intercalation of Li plating into adjacent graphite particles during the rest period. The exponential increase of capacity recovery and T SH as a function of time suggests a reaction of 1st order for the relaxation process.

  14. Seroepidemiological detection of antibodies against Leptospira spp using microscopic agglutination test in Urmia cows and sheep

    Directory of Open Access Journals (Sweden)

    Ramin Ag

    2013-01-01

    Full Text Available The study was designed to determine the level of incidence, titer and various serovars of leptospira in 203 cows and 166 sheep at Urmia abattoir in 2011. Blood samples were collected during the slaughter of animals and sera were separated to evaluate the serological reaction to Leptospira spp by Microscopic Agglutination Test (MAT using live antigens representing Leptospira interrogans serogroups: pomona, grippotyphosa, canicola, hardjo, icterrohaemoragiae, and ballum. Overall, 36% of cows and 19.3% of sheep including 33.8% of bulls, 40.5% of female cows, 18.3% of rams and 25% of ewes had a positive reaction to at least one of the leptospira serovars. The most prevalent serovars in cows were pomona (22.7%, grippotyphosa (13.8%, and hardjo (8.4%, and in sheep were grippotyphosa (66.7%, pomona (26.2% and canicola (7.1%. Other serovars were not detected in cows and sheep. The most prevalent serological titers of 1:100 and 1:200 in cows was 18.2% and 26.6%, and for sheep were 13.5% and 8%, respectively, and of 1:400 in sheep was 2.3%. Cows with a positive reaction to one, two and three serovars were 28.6%, 5.9%, and 1.5% and sheep positive to one and two serovars were 13.3% and 6%, respectively. Age comparison in seropositive cows and sheep showed a significantly increased infection (p<0.05 from young to adult ruminants, while no differences were seen regarding gender. The main mixed serovars were between grippotyphosa/pomona, grippotyphosa/canicola and canicola/pomona. The gender comparison of the serovars' distribution revealed that the pomona and grippotyphosa were predominant among other leptospiral serovars in cows and sheep, respectively. In conclusion, the rate of leptospirosis in Urmia cows was about 2 fold in sheep. The most current serovars in cows and sheep were pomona and grippotyphosa, respectively. The majority of animals was infected with one serovar, but polyserovars, are also possible. The highest titer (1:200 was observed in cows

  15. Postirradiation examination of high-U-loaded, low-enriched U3O8, UAl2, and U3Si test fuel plates

    International Nuclear Information System (INIS)

    Gomez, J.; Morando, R.; Perez, E.E.; Giorsetti, D.R.; Copeland, G.L.; Hofman, G.L.; Snelgrove, J.L.

    1985-01-01

    The scope of this work is to present an evaluation of the postirradiation examination of the second set of high-U-loaded, low-enriched U 3 O 8 , UAl 2 and U 3 Si miniature plates manufactured by the Comision Nacional de Energia Atomica (CNEA) of Argentina, and irradiated and examined, within the framework of the Reduced Enrichment Research and Test Reactor (RERTR) Program, at Oak Ridge National Laboratory and Argonne National Laboratory. This paper includes fabrication details of the plates, their irradiation history and the results of postirradiation examination which are compared to those of the previous test and to present results from other laboratories participating in the RERTR Program. Postirradiation examination of these plates showed satisfactory performance for the oxides, aluminides and silicides (except for the highest-loaded U 3 Si plate) with the only indication of detrimental behavior being the slight bowing of some plates at about 80% burnup

  16. Postirradiation examination of high-U-loaded, low-enriched U3O8, UAl2, and U3Si test fuel plates

    International Nuclear Information System (INIS)

    Gomez, J.; Morando, R.; Perez, E.E.; Giorsetti, D.R.; Copeland, G.L.; Hofman, G.L.; Snelgrove, J.L.

    1985-01-01

    The scope of this work is to present an evaluation of the postirradiation examination of the second set of high-U-loaded, low-enriched U 3 O 8 , UAl 2 and U 3 Si miniature plates manufactured by the Comision Nacional de Energia Atomica (CNEA) of Argentina, and irradiated and examined, within the framework of the Reduced Enrichment Research and Test Reactor (RERTR) Program, at Oak Ridge National Laboratory and Argonne National Laboratory. This paper includes fabrication details of the plates, their irradiation history and the results of postirradiation examination which are compared to those of the previous test and to present results from other laboratories participating in the REM Program. Postirradiation examination of these plates showed satisfactory performance for the oxides, aluminides and silicides (except for the highest-loaded U 3 Si plate) with the only indication of detrimental behavior being the slight bowing of some plates at about 80% burnup. (author)

  17. Postirradiation examination of high-U-loaded low-enriched U3O8, UAl2, and U3Si test fuel plates

    International Nuclear Information System (INIS)

    Gomez, J.; Morando, R.; Perez, E.E.; Giorsetti, D.R.; Copeland, G.L.; Hofmann, G.; Snelgrove, J.L.

    1984-01-01

    The scope of this work is to present an evaluation of the postirradiation examination of the second set of high-U-loaded low-enriched U 3 O 8 , UAl 2 and U 3 Si miniature plates manufactured by the Comision Nacional de Energia Atomica (CNEA) of Argentina, and irradiated and examinated, within the framework of the Reduced Enrichment Research and Test Reactor (RERTR) Program, at Oak Ridge National Laboratory and Argonne National Laboratory. This paper includes fabrication details of the plates, their irradiation history and the results of postirradiation examination which are compared to those of the previous test and to present results from other laboratories participating in the RERTR Program. Postirradiation examination of these plates showed satisfactory poerformance for the oxides, aluminides and silicides (except for the highest-loaded U 3 Si plate) with the only indication of detrimental behavior during the slight bowing of some plates at about 80% burnup

  18. Evaluation of a New and Rapid Serologic Test for Detecting Brucellosis: Brucella Coombs Gel Test.

    Science.gov (United States)

    Hanci, Hayrunisa; Igan, Hakan; Uyanik, Muhammet Hamidullah

    2017-01-01

    Many serological tests have been used for the diagnosis of human brucellosis. A new serological method is identified as Brucella Coombs gel test based on the principle of centrifugation gel system similar to the gel system used in blood group determination. In this system, if Brucella antibodies were present in the serum, antigen and antibody would remain as a pink complex on the gel. Otherwise, the pink Brucella antigens would precipitate at the bottom of the gel card system. In this study, we aimed to compare the Brucella Coombs gel test, a new, rapid screen and titration method for detection of non-agglutinating IgG with the Brucella Coombs test. For this study, a total of 88 serum samples were obtained from 45 healthy persons and 43 individuals who had clinical signs and symptoms of brucellosis. For each specimen, Rose Bengal test, standard agglutination test, Coombs test and Brucella Coombs gel test were carried out. Sensitivity and specificity of Brucella Coombs gel test were found as 100.0 and 82.2%, respectively. Brucella Coombs gel test can be used as a screening test with high sensitivity. By the help of pink Brucella antigen precipitation, the tests' evaluation is simple and objective. In addition, determination of Brucella antibody by rapid titration offers another important advantage.

  19. Detección de anticuerpos anti-Brucella spp. en cerdos mediante técnicas de aglutinación y ELISA indirecto en las provincias de Buenos Aires y La Pampa: Argentina Detection of anti-Brucella spp. antibodies in swine by agglutination techniques and indirect ELISA in the Buenos Aires and La Pampa provinces: Argentina

    Directory of Open Access Journals (Sweden)

    H.A. Castro

    2006-04-01

    Full Text Available En nuestro país no existe un programa de control sobre brucelosis porcina y su verdadera situación epidemiológica es desconocida. El objetivo de nuestro trabajo fue detectar la presencia de anticuerpos anti-Brucella spp. en porcinos provenientes de criaderos del sudoeste de la provincia de Buenos Aires y del este de la provincia de La Pampa. La toma de muestras de sangre se realizó en el momento del faenado de los animales. La detección de anticuerpos se efectuó mediante las técnicas de aglutinación con antígeno tamponado en placa (BPA, seroaglutinación en tubo (SAT, aglutinación con 2-ME (2-ME y ELISA indirecto, con dos antígenos diferentes: el antígeno CYT (fracción citoplasmática de B. abortus S19 y el antígeno CP (extracto citoplasmático libre de lipopolisacárido. Del total de las muestras analizadas (n=325, el 17,8% fue positivo para BPA, el 13,8% fue positivo para SAT y sólo el 8,0% fue positivo para 2-ME. Mediante ELISA-CYT, este porcentaje se elevó a 21,0%, mientras que a través del ELISA-CP sólo se halló un 10,0% de muestras reactivas. Estos resultados son compatibles con los informados en los escasos reportes previos para todo el país y sugieren la necesidad de extender los estudios a otras zonas, donde sea habitual la cría de cerdos.Porcine brucellosis is one of the most important zoonoses in this country. Currently, there is no control program for porcine brucellosis in Argentina and the epidemiological situation is still unknown. The purpose of our study was to detect anti-Brucella spp. antibodies in swine in the southwest of the Buenos Aires province and the east of the La Pampa province. Blood samples were obtained when animals were slaughtered. The presence of anti-brucella antibodies was studied by the buffered plate agglutination test (BPA, the tube agglutination test (SAT, the 2-mercaptoethanol (2-ME agglutination test and indirect ELISA tests, using the cytosolic fraction from Brucella abortus S19

  20. Light transmission aggregometry using pre-coated microtiter plates and a Victor X5 plate reader

    DEFF Research Database (Denmark)

    Vinholt, Pernille Just; Nybo, Mads; Nielsen, Camilla Brødsgaard

    2017-01-01

    Background Light transmission aggregometry (LTA) can be performed with microtiter plates (96-well LTA). When conducting LTA, an agonist is added to platelet-rich plasma and the sample is shaken for minutes after which absorbance readings are done. Platelet aggregation is detected as decrease...... in absorbance. However, the classical method is cumbersome and therefore microtiter plates can be used for concomitant testing of multiple samples. Furthermore, it would be convenient to prepare the plate in advance of platelet aggregation testing. Aim: The aim of the present study was to establish a simplified...

  1. Foraminiferans as food for Cephalaspideans (Gastropoda: Opisthobranchia), with notes on secondary tests around calcareous foraminiferans

    DEFF Research Database (Denmark)

    Cedhagen, Tomas

    1996-01-01

    species, Ammonia batavus and two agglutinating species, Ammoscalaria pseudospiralis and Ammotium cassis. The test (shell) material of the latter two species was sand grains (quartz). It was inferred that the gastropods avoid agglutinating foraminiferans as food. Many calcareous but not agglutinating......The food of four species of Cephalaspidea (Philine aperta, Philine denticulata, Philine scabra and Cylichna cylindracea) was studied in animals collected on silty clay bottoms at 20-35 m depth on the west coast of Sweden. The specimens were dissected. Only calcareous foraminiferans were found...... foraminiferans surround themselves with a “secondary test”, a cyst or covering of foreign particles around the test. This structure has earlier been called a “reproductive cyst” or “feeding cyst” in some species. “Secondary tests” are primarily connected with feeding, but might also be a preadaptation for other...

  2. Testing of Some Canine Blood Types in Transfusion Compatibility Assessment

    Directory of Open Access Journals (Sweden)

    L Ognean

    2014-01-01

    Full Text Available Blood types were determined using SHIGETA (n=136 and DEA1.1 (n=25 kits, in two groups of dogs, consisting of patients that underwent blood transfusions and healthy donors. The tests were conducted in accordance with the procedures established by the manufacturers, using specific monoclonal antibodies kits, heparinized blood for the tube agglutination (TUBE and slide (SLIDE methods, and EDTA treated blood for the CARD and chromatographic (CHROM methods. The clear expression of tube agglutination reaction in the SHIGETA kit provided a good detection of antigens. Positive reactions with anti-DEA1.1 were clear and evident with the CHROM test. SHIGETA tests revealed a predominance 1.1B (47.05% of blood type, common in Rotweilers (81.81% and Romanian Shepherds (73.68% and group 1(-B (24.26%, frequently found in German Shepherds (54.16%, these also representing an important source of compatible blood. DEA1.1 type test, revealed a high frequency of positive dogs (75%, associated with lower number of potential donors. Extrapolation of SHIGETA groups into the DEA system, confirmed the 1(-B positive dogs as DEA 1.1 negative, and their prevalence in German Shepherds also confirmed their known tendency to be “ideal donors”. The CHROME test showed a good efficiency in auto agglutination control and detecting DEA1.1 positive dogs, including patients with severe forms of anemia.

  3. Sensitivity, specificity and predictive probability values of serum agglutination test titres for the diagnosis of Salmonella Dublin culture-positive bovine abortion and stillbirth.

    Science.gov (United States)

    Sánchez-Miguel, C; Crilly, J; Grant, J; Mee, J F

    2018-06-01

    The objective of this study was to determine the diagnostic value of maternal serology for the diagnosis of Salmonella Dublin bovine abortion and stillbirth. A retrospective, unmatched, case-control study was carried out using twenty year's data (1989-2009) from bovine foetal submissions to an Irish government veterinary laboratory. Cases (n = 214) were defined as submissions with a S. Dublin culture-positive foetus from a S. Dublin unvaccinated dam where results of maternal S. Dublin serology were available. Controls (n = 415) were defined as submissions where an alternative diagnosis other than S. Dublin was made in a foetus from an S. Dublin unvaccinated dam where the results of maternal S. Dublin serology were available. A logistic regression model was fitted to the data: the dichotomous dependent variable was the S. Dublin foetal culture result, and the independent variables were the maternal serum agglutination test (SAT) titre results. Salmonella serology correctly classified 87% of S. Dublin culture-positive foetuses at a predicted probability threshold of 0.44 (cut-off at which sensitivity and specificity are at a maximum, J = 0.67). The sensitivity of the SAT at the same threshold was 73.8% (95% CI: 67.4%-79.5%), and the specificity was 93.2% (95% CI: 90.3%-95.4%). The positive and negative predictive values were 84.9% (95% CI: 79.3%-88.6%) and 87.3% (95% CI: 83.5%-91.3%), respectively. This study illustrates that the use of predicted probability values, rather than the traditional arbitrary breakpoints of negative, inconclusive and positive, increases the diagnostic value of the maternal SAT. Veterinary laboratory diagnosticians and veterinary practitioners can recover from the test results, information previously categorized, particularly from those results declared to be inconclusive. © 2017 Blackwell Verlag GmbH.

  4. Beam test results of a resistive plate chamber made of Chinese bakelites

    CERN Document Server

    Ying, J; Ban, Y; Liu Hong Tao; Zhu, Z M; Zhu, Z Y; Chen, T; Ma Jing Guo; Qian, S J

    2001-01-01

    The detailed beam test results of the first Chinese made avalanche mode resistive plate chamber are reported. The experimental set-ups at CERN GIF area are introduced. The detection efficiency, position resolution and time resolution of the chamber fulfil requirements as muon trigger for the future LHC experiments, while the rate capability is not good enough if the chamber is used at forward region. The applicability and the further possible improvements of the chamber are discussed. (12 refs).

  5. Modeling RERTR experimental fuel plates using the PLATE code

    International Nuclear Information System (INIS)

    Hayes, S.L.; Meyer, M.K.; Hofman, G.L.; Snelgrove, J.L.; Brazener, R.A.

    2003-01-01

    Modeling results using the PLATE dispersion fuel performance code are presented for the U-Mo/Al experimental fuel plates from the RERTR-1, -2, -3 and -5 irradiation tests. Agreement of the calculations with experimental data obtained in post-irradiation examinations of these fuels, where available, is shown to be good. Use of the code to perform a series of parametric evaluations highlights the sensitivity of U-Mo dispersion fuel performance to fabrication variables, especially fuel particle shape and size distributions. (author)

  6. Seafloor spreading on the Southeast Indian Ridge over the last one million years: a test of the Capricorn plate hypothesis

    Science.gov (United States)

    Conder, James A.; Forsyth, Donald W.

    2001-05-01

    Plate motions in the Indian Ocean are inconsistent with a rigid Indo-Australian plate. An equatorial, diffuse boundary dividing the plate into separate Indian and Australian plates significantly improves the fit of kinematic plate models to the spreading rates, transform azimuths, and earthquake slip vectors on the spreading center boundaries. An additional boundary, further dividing the Australian plate into Australian and Capricorn plates has been proposed to account for much of the remaining inconsistency and the pattern of intraplate earthquakes [J.-Y. Royer, R.G. Gordon, Science 277 (1997) 1268-1274]. The proposed boundary is ˜2000 km wide where it intersects the Southeast Indian Ridge. Several recent geophysical cruises to the Southeast Indian Ridge, including a cruise within the proposed boundary, provide many new data for investigating the validity of the Capricorn plate model. These new observations strongly support the hypothesis that the Capricorn plate exists. Statistical tests of the data from the Southeast Indian Ridge alone are not sufficient to confirm it, but motion about the Rodriguez Triple Junction (RTJ) suggests some non-rigidity in the Antarctica-Australia-Somalia circuit. Inferred deformation with enforced closure about the RTJ leads to an estimate of plate motion consistent with the Capricorn plate model. However, the diffuse Capricorn-Australia boundary does not extend south of the St. Paul Fracture Zone, 800 km narrower than the previously proposed boundary.

  7. Sensitivity and specificity of various serologic tests for detection of Toxoplasma gondii infection in naturally infected sows

    DEFF Research Database (Denmark)

    Dubey, J.P.; Thulliez, P.; Weigel, R.M.

    1995-01-01

    antibodies by use of the modified agglutination test (MAT), latex agglutination test (LAT), indirect hemagglutination test (IHAT), and ELISA. Toxoplasma gondii was isolated from 170 hearts of 1,000 sows by bioassays in mice and cats. The percentage of samples diagnosed as positive for each of the serologic......, 29.4 and 98.3% for IHAT, 45.9 and 96.9% for LAT, and 72.9 and 85.9% for ELISA. The dye test was run at 1:20 dilution on only 893 sera because of bacterial contamination and presence of anticomplement substances. Dye test antibodies were found in 17.8% of the sera, and sensitivity and specificity were...

  8. Visual illusions and plate design: the effects of plate rim widths and rim coloring on perceived food portion size.

    Science.gov (United States)

    McClain, A D; van den Bos, W; Matheson, D; Desai, M; McClure, S M; Robinson, T N

    2014-05-01

    The Delboeuf Illusion affects perceptions of the relative sizes of concentric shapes. This study was designed to extend research on the application of the Delboeuf illusion to food on a plate by testing whether a plate's rim width and coloring influence perceptual bias to affect perceived food portion size. Within-subjects experimental design. Experiment 1 tested the effect of rim width on perceived food portion size. Experiment 2 tested the effect of rim coloring on perceived food portion size. In both experiments, participants observed a series of photographic images of paired, side-by-side plates varying in designs and amounts of food. From each pair, participants were asked to select the plate that contained more food. Multilevel logistic regression examined the effects of rim width and coloring on perceived food portion size. Experiment 1: participants overestimated the diameter of food portions by 5% and the visual area of food portions by 10% on plates with wider rims compared with plates with very thin rims (Pfood portion sizes. Experiment 2: participants overestimated the diameter of food portions by 1.5% and the visual area of food portions by 3% on plates with rim coloring compared with plates with no coloring (P=0.01). The effect of rim coloring was greater with smaller food portion sizes. The Delboeuf illusion applies to food on a plate. Participants overestimated food portion size on plates with wider and colored rims. These findings may help design plates to influence perceptions of food portion sizes.

  9. Determination of elastic constants of fuels plates based on uranium by ultrasound testing

    International Nuclear Information System (INIS)

    Moreira Castro, Martin Ignacio

    2015-01-01

    Current nuclear reactors use as U-235 U-enriched compounds enriched with U-235, requiring U-alloys that increase the amount of atoms available for nuclear fission in a convenient way. This study was carried out on fuel plates manufactured in the Chilean Nuclear Energy Commission, whose cores are composed of a dispersed mixture Al-U_3Si_2 and Al-U_7Mo, with different densities of uranium, covered by a coating of Al6061. The objective was to characterize elastically and classify the fuel plates analyzed. Specifically, five Al-U_3Si_2 fuel plates with 1.7 gU/cm"3, eight A-U_3Si_2 with 3.4 gU/cm"3, five of A-l U_3Si_2 with 4.8 gU/cm"3 were successfully studied. The apparent elastic constants (Young and Shear modules, and Poisson coefficient) were determined in the area where the fuel is located (MEAT) by means of an ultrasound sampling technique, thus being able to characterize them and classify them according to their composition. The behavior of the elastic constants generally shows a tendency to decrease as the amount of U_3Si_2 particles dispersed in the MEAT zone of the fuel plates increases. In addition, the non-destructive test method used made it possible to detect several differences between the fuel plates analyzed, such as the amount of reduction in rolling, among others. Additionally, six experimental fuel miniplates were analyzed whose meat were formed by a dispersion of the Al-UMo type, specifically: two of Al-U_7Mo with 6.0 gU/cm"3, two of Al-U_7Mo with 7.0 gU/ cm"3 and two of Al-U_7Mo with 8.0 gU/cm"3. The response of the U-Mo fuel miniplates against this technique was not good, so several ideas were proposed to improve this situation

  10. Evaluation of Four Bedside Test Systems for Card Performance, Handling and Safety.

    Science.gov (United States)

    Giebel, Felix; Picker, Susanne M; Gathof, Birgit S

    2008-01-01

    SUMMARY: OBJECTIVE: Pretransfusion ABO compatibility testing is a simple and required precaution against ABO-incompatible transfusion, which is one of the greatest threats in transfusion medicine. While distinct agglutination is most important for correct test interpretation, protection against infectious diseases and ease of handling are crucial for accurate test performance. Therefore, the aim of this study was to evaluate differences in test card design, handling, and user safety. DESIGN: Four different bedside test cards with pre-applied antibodies were evaluated by 100 medical students using packed red blood cells of different ABO blood groups. Criteria of evaluation were: agglutination, labelling, handling, and safety regarding possible user injuries. Criteria were rated subjectively according to German school notes ranging from 1 = very good to 6 = very bad/insufficient. RESULTS: Overall, all cards received very good/good marks. The ABO blood group was identified correctly in all cases. Three cards (no. 1, no. 3, no. 4) received statistically significant (p labelling (1.5 vs. 2.2-2.4), handling (1.9-2.0 vs. 2.5), and user safety (2.5 vs. 3.4). Analysis of card self-explanation revealed no remarkable differences. CONCLUSION: Despite good performance of all card systems tested, the best results when including all criteria evaluated were obtained with card no. 4 (particularly concerning clear agglutination), followed by cards no. 2, no. 1, and no. 3.

  11. Vibrio cholerae O1 secretes an extracellular matrix in response to antibody-mediated agglutination.

    Directory of Open Access Journals (Sweden)

    Danielle E Baranova

    Full Text Available Vibrio cholerae O1 is one of two serogroups responsible for epidemic cholera, a severe watery diarrhea that occurs after the bacterium colonizes the human small intestine and secretes a potent ADP-ribosylating toxin. Immunity to cholera is associated with intestinal anti-lipopolysaccharide (LPS antibodies, which are known to inhibit V. cholerae motility and promote bacterial cell-cell crosslinking and aggregation. Here we report that V. cholerae O1 classical and El Tor biotypes produce an extracellular matrix (ECM when forcibly immobilized and agglutinated by ZAC-3 IgG, an intestinally-derived monoclonal antibody (MAb against the core/lipid A region of LPS. ECM secretion, as demonstrated by crystal violet staining and scanning electron microscopy, occurred within 30 minutes of antibody exposure and peaked by 3 hours. Non-motile mutants of V. cholerae did not secrete ECM following ZAC-3 IgG exposure, even though they were susceptible to agglutination. The ECM was enriched in O-specific polysaccharide (OSP but not Vibrio polysaccharide (VPS. Finally, we demonstrate that ECM production by V. cholerae in response to ZAC-3 IgG was associated with bacterial resistant to a secondary complement-mediated attack. In summary, we propose that V. cholerae O1, upon encountering anti-LPS antibodies in the intestinal lumen, secretes an ECM (or O-antigen capsule possibly as a strategy to shield itself from additional host immune factors and to exit an otherwise inhospitable host environment.

  12. Results of ITER toroidal field coil cover plate welding test

    International Nuclear Information System (INIS)

    Koizumi, Norikiyo; Matsui, Kunihiro; Shimizu, Tatsuya; Nakajima, Hideo; Iijima, Ami; Makino, Yoshinobu

    2012-01-01

    In ITER Toroidal Field (TF) coils, cover plates (CP) are welded to the teeth of the radial plate (RP) to fix conductors in the grooves of the RP. Though the total length of the welds is approximately 1.5 km and the height and width of the RP are 14 and 9 m, respectively, welding deformation of smaller than 1 mm for local out-of-plane distortion and smaller than several millimeters for in-plane deformation is required. Therefore, laser welding is used for CP welding to reduce welding deformation as much as possible. However, the gap in welding joints is expected to be a maximum of 0.5 mm. Thus, a laser welding technique to enable welding of joints with a gap of 0.5 mm in width has been developed. Applying this technology, a CP welding trial using an RP mock-up was successfully performed. The achieved local flatness, that is, the flatness of the cross-section of the RP mock-up, is 0.6 mm. The analysis using inherent strains, which are derived from the welding test using flat plates, also indicates that better local flatness can be achieved if the initial distortion is zero. In addition, the welding deformation of a full-scale RP is evaluated via analysis using the inherent strain. The analytical results show that in-plane deformation is approximately 5 mm and large out-of-plane deformation, consisting of approximately 5 mm-long wave distortion and a twist of approximately 1.5 mm in the RP cross-section, is generated. It is expected that the required profile can be achieved by determining the original geometry of an RP by simulating deformation during welding. It is also expected that the required local flatness of a DP can be achieved, since out-of-plane deformation can be reduced by increasing the number of RPs turned over during CP welding. A more detailed study is required. (author)

  13. Plating on some difficult-to-plate metals and alloys

    International Nuclear Information System (INIS)

    Dini, J.W.; Johnson, H.R.

    1980-02-01

    Electrodeposition of coatings on metals such as beryllium, beryllium-copper, Kovar, lead, magnesium, thorium, titanium, tungsten, uranium, zirconium, and their alloys can be problematic. This is due in most cases to a natural oxide surface film that readily reforms after being removed. The procedures we recommend for plating on these metals rely on replacing the oxide film with a displacement coating, or etching to allow mechanical keying between the substrate and plated deposit. The effectiveness of the procedures is demonstrated by interface bond strengths found in ring-shear and conical-head tensile tests

  14. Four new species of deep water agglutinated foraminifera from the Oligocene-Miocene of the Congo Fan (offshore Angola)

    OpenAIRE

    Kender, S.; Kaminski, M. A.; Jones, R. W.

    2006-01-01

    Four new species of deep-water agglutinated benthic foraminifera are described from the Oligocene and Miocene of the Congo Fan, offshore Angola. Scherochorella congoensis n.sp., Paratrochamminoides goroyskiformis n.sp., Haplophragmoides nauticus n.sp. and Portatrochammina profunda n.sp. all occur in deep-sea turbiditic shales and sands from the distal section of the Congo Fan.

  15. Molecular identification of Mycoplasma synoviae from seroprevalent commercial breeder farms at Chittagong district, Bangladesh

    Directory of Open Access Journals (Sweden)

    Md. Inkeyas Uddin

    2016-10-01

    Full Text Available Aim: Worldwide, Mycoplasma synoviae (MS is an important pathogen of poultry, especially for chicken and turkey. It causes respiratory tract infection and infectious sinusitis. The study was conducted to determine the seroprevalence of MS infection with associated risk factors and identification of MS organism in unvaccinated flocks of commercial breeder farms of the Chittagong district, Bangladesh. Materials and Methods: A total of 365 serum samples were collected and tested for MS using serum plate agglutination (SPA test for determination of MS seroprevalence. On the other hand, tracheal swabs were collected from each seropositive flocks for polymerase chain reaction (PCR to determine the presence of MS organism. Results: Among the farms, the highest prevalence was found to be 69% and the lowest prevalence was 28% with the average 60%. The seroprevalence of MS infection in breeder farms was highest 70% with the flock size >10,000 birds, whereas it was lowest 57% in the flocks ranging from 4000 to 7000. According to age group, the prevalence was found highest 70% in >60 weeks age group of birds and lowest 42% in 10-19 weeks group. The seroprevalence of MS in winter season was found as highest as 64%, whereas it was found lowest 60% in the summer season. There was a statistically significant difference (p0.05 difference in the winter, summer, and rainy season. To confirm the presence of MS in the samples, PCR test was applied using specific primers to amplify a 214 bp region of the 16S rRNA gene of the organism. In PCR, all seropositive flocks showed a positive result for MS. Conclusion: As the plate agglutination test result showed 100% similar with PCR result, it can be suggested that agglutination test is better than molecular and culture techniques for MS detection and it is also cheaper and less time-consuming method.

  16. Buckling analysis for axially compressed flat plates, structural sections, and stiffened plates reinforced with laminated composites

    Science.gov (United States)

    Viswanathan, A. V.; Soong, T.; Miller, R. E., Jr.

    1971-01-01

    A classical buckling analysis is developed for stiffened, flat plates composed of a series of linked plate and beam elements. Plates are idealized as multilayered orthotropic elements. Structural beads and lips are idealized as beams. The loaded edges of the stiffened plate are simply-supported and the conditions at the unloaded edges can be prescribed arbitrarily. The plate and beam elements are matched along their common junctions for displacement continuity and force equilibrium in an exact manner. Offsets between elements are considered in the analysis. Buckling under uniaxial compressive load for plates, sections, and stiffened plates is investigated. Buckling loads are the lowest of all possible general and local failure modes, and the mode shape is used to determine whether buckling is a local or general instability. Numerical correlations with existing analysis and test data for plates, sections, and stiffened plates including boron-reinforced structures are discussed. In general correlations are reasonably good.

  17. Evaluation of the Sensititre MycoTB plate for susceptibility testing of the Mycobacterium tuberculosis complex against first- and second-line agents.

    Science.gov (United States)

    Hall, Leslie; Jude, Kurt P; Clark, Shirley L; Dionne, Kim; Merson, Ryan; Boyer, Ana; Parrish, Nicole M; Wengenack, Nancy L

    2012-11-01

    The Sensititre MycoTB plate (TREK Diagnostic Systems, Cleveland, OH) uses a microtiter plate MIC format for susceptibility testing of Mycobacterium tuberculosis complex isolates against first- and second-line antituberculosis agents. Categorical agreement versus the agar proportion method for 122 M. tuberculosis complex isolates was 94% to 100%.

  18. Standardized performance tests of collectors of solar thermal energy - A flat-plate copper collector with parallel mylar striping

    Science.gov (United States)

    Johnson, S. M.

    1976-01-01

    Basic test results are reported for a flat plate solar collector whose performance was determined in a solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and one coolant flow rate. Collector efficiency is correlated in terms of inlet temperature and flux level.

  19. Integration of agglutination assay for protein detection in microfluidic disc using Blu-ray optical pickup unit and optical fluid scanning

    DEFF Research Database (Denmark)

    Uddin, Rokon; Burger, Robert; Donolato, Marco

    2015-01-01

    We present a novel strategy for thrombin detection by combining a magnetic bead based agglutination assay and low-cost microfluidic disc. The detection method is based on an optomagnetic readout system implemented using a Blu-ray optical pickup unit (OPU) as main optoelectronic component. The ass...

  20. Evaluation of the base/subgrade soil under repeated loading : phase II, in-box and ALF cyclic plate load tests.

    Science.gov (United States)

    2012-03-01

    This research study aims at evaluating the performance of base and subgrade soil in flexible pavements under repeated loading test conditions. For this purpose, an indoor cyclic plate load testing equipment was developed and used to conduct a series ...

  1. Removal of Lipid from Serum Increases Coherence between Brucellosis Rapid Agglutination Test and Enzyme-linked Immunosorbent Assay in Bears in Alaska, USA.

    Science.gov (United States)

    Godfroid, Jacques; Beckmen, Kimberlee; Helena Nymo, Ingebjørg

    2016-10-01

    In cases of chronic Brucella spp. infection, results of the rose bengal plate test (RBPT) and indirect enzyme-linked immunosorbent assay (ELISA) should be coherent, as reported in controlled conditions in the literature. We compared RBPT and ELISA results in 58 Alaska grizzly bears ( Ursus arctos horribilis), eight Kodiak brown bears ( Ursus arctos middendorffi), and six Alaska Peninsula brown bears ( Ursus arctos gyas). Of the 72 bears tested, 42 (58%) were ELISA positive and 53 (73%) were RBPT positive. However, the coherence between the tests was only fair (K=0.37, SE=0.11), suggesting that either the serologic results were not compatible with Brucella spp. infection or that there was a technical problem with the tests. To address a potential technical problem, we performed a 30-min chloroform/centrifugation cleanup. Following cleanup, the ELISA identified 43 positives (59%) and the RBPT identified 47 (65%), and the coherence between the tests was much improved (K=0.80, SE=0.07). We recommend cleaning wildlife sera with a high lipid content before performing RBPT and performing RBPT and ELISA in parallel to assess coherence. Our results suggest that Alaskan brown bears have been exposed to Brucella spp.

  2. Solid phase radioimmunoassay for quantitation of IgM rheumatoid factor (RF). Comparison with agglutination techniques and radioimmunoprecipitation polyethylene glycol assay (RIPEGA)

    Energy Technology Data Exchange (ETDEWEB)

    Herrmann, D.; Jaeger, L.; Hein, G.; Henzgen, M.; Fiebig, H.; Schlenvoigt, G.; Vogelsang, H. (Friedrich-Schiller-Universitaet, Jena (German Democratic Republic). Bereich Medizin; Karl-Marx-Universitaet, Leipzig (German Democratic Republic). Sektion Biowissenschaften)

    1985-01-01

    A solid-phase radioimmunoassay capable of detecting nanogram quantities of human IgM rheumatoid factor using a monoclonal anti-..mu..-chain antibody is described. Human IgG did not interfere with the detection of IgM RF by this method. The small nonspecific binding of nonRF IgM to the human IgG coated tubes utilized in the assay must be corrected for by assaying samples in parallel bovine serum albumin coated control tubes only in cases of deviation of IgM from normal range. 69 coded and randomly arranged sera from patients with rheumatoid arthritis (RA), nonrheumatic joint diseases and healthy adult control subjects were investigated by this method, agglutination techniques as well as RIPEGA. A good correlation between solid-phase radioimmunoassay and agglutination techniques was found. Patients with seropositive RA had significantly higher concentrations of IgM RF than seronegative RA patients or control subjects.

  3. Ammolagena clavata (Jones and Parker, 1860), an agglutinated benthic foraminiferal species - first report from the Recent sediments, Arabian Sea, Indian Ocean region

    Digital Repository Service at National Institute of Oceanography (India)

    Nigam, R.; Mazumder, A.; Saraswat, R.

    The rare presence of the agglutinated foraminiferal species Ammolagena clavata is presented for the first time from the Recent sediments of the Indian Ocean region. This species has previously been reported in Recent sediments from all other oceans...

  4. Stress analyses of flat plates with attached nozzles. Vol. 2: Experimental stress analyses of a flat plate with one nozzle attached

    International Nuclear Information System (INIS)

    Battiste, R.L.; Peters, W.H.; Ranson, W.F.; Swinson, W.F.

    1975-07-01

    Vol. 1 of this report compares experimental results with theoretical stress distributions for a flat plate with one nozzle configuration and for a flat plate with two closely spaced nozzles attached. This volume contains the complete test results for a flat plate with one nozzle attached that was subjected to 1:1 and 1:2 biaxial planar loadings on the plate, to a thrust loading on the nozzle, and to a moment loading on the nozzle. The plate tested was 36 x 36 x 0.375 in., and the attached nozzle had an outer dia of 2.625 in. and a 0.250-in.-thick wall. The nozzle was located in the center of the plate and was considered to be free of weld distortions and irregularities in the junction area. (U.S.)

  5. Neutron radiography using neutron imaging plate

    International Nuclear Information System (INIS)

    Chankow, Nares; Wonglee, Sarinrat

    2008-01-01

    Full text: The aims of this research are to study properties of neutron imaging plate, to obtain a suitable condition for neutron radiography and to use the neutron imaging plate for testing of materials nondestructively. The experiments were carried out by using a neutron beam from the Thai Research Reactor TRR-1/M1 at a power of 1.2 MW. A BAS-ND 2040 FUJI neutron imaging plate and a MX125 Kodak X-ray film/Gadolinium neutron converter screen combination were tested for comparison. It was found that the photostimulated light (PSL) read out of the imaging plate was directly proportional to the exposure time. It was also found that radiography with neutron using the imaging plate was approximately 40 times faster than the conventional neutron radiography using x-ray film/Gd converter screen combination. The sensitivity of the imaging plate to gamma-rays was investigated by using gamma-rays from an 192 Ir and a 60 Co radiographic sources. The imaging plate was found to be 5-6 times less sensitive to gamma-rays than a FUJI BAS-MS 2040 gamma-ray imaging plate. Finally, some specimens were selected to be radiographed with neutrons using the imaging plate and the x-ray film/Gd converter screen combination in comparison to x-rays. Parts containing light elements could be clearly observed by the two neutron radiographic techniques. It could be concluded that the image quality from the neutron imaging plate was comparable to the conventional x-ray film/Gd converter screen combination but the exposure time could be approximately reduced by a factor of 40

  6. Biomechanical comparison of double-row locking plates versus single- and double-row non-locking plates in a comminuted metacarpal fracture model.

    Science.gov (United States)

    Gajendran, Varun K; Szabo, Robert M; Myo, George K; Curtiss, Shane B

    2009-12-01

    Open or unstable metacarpal fractures frequently require open reduction and internal fixation. Locking plate technology has improved fixation of unstable fractures in certain settings. In this study, we hypothesized that there would be a difference in strength of fixation using double-row locking plates compared with single- and double-row non-locking plates in comminuted metacarpal fractures. We tested our hypothesis in a gap metacarpal fracture model simulating comminution using fourth-generation, biomechanical testing-grade composite sawbones. The metacarpals were divided into 6 groups of 15 bones each. Groups 1 and 4 were plated with a standard 6-hole, 2.3-mm plate in AO fashion. Groups 2 and 5 were plated with a 6-hole double-row 3-dimensional non-locking plate with bicortical screws aimed for convergence. Groups 3 and 6 were plated with a 6-hole double-row 3-dimensional locking plate with unicortical screws. The plated metacarpals were then tested to failure against cantilever apex dorsal bending (groups 1-3) and torsion (groups 4-6). The loads to failure in groups 1 to 3 were 198 +/- 18, 223 +/- 29, and 203 +/- 19 N, respectively. The torques to failure in groups 4 to 6 were 2,033 +/- 155, 3,190 +/- 235, and 3,161 +/- 268 N mm, respectively. Group 2 had the highest load to failure, whereas groups 5 and 6 shared the highest torques to failure (p row plates had equivalent bending and torsional stiffness, significantly higher than observed for the single-row non-locking plate. No other statistical differences were noted between groups. When subjected to the physiologically relevant forces of apex dorsal bending and torsion in a comminuted metacarpal fracture model, double-row 3-dimensional non-locking plates provided superior stability in bending and equivalent stability in torsion compared with double-row 3-dimensional locking plates, whereas single-row non-locking plates provided the least stability.

  7. Post-irradiation studies of test plates for low enriched fuel elements for research reactors

    International Nuclear Information System (INIS)

    Groos, E.; Buecker, H.J.; Derz, H.; Schroeder, R.

    1988-07-01

    In developing new fuels for research reactor elements that allow the use of low enriched uranium (LEU) 3 Si 2 , U 3 Si 1.5 , U 3 Si 1.3 and U 3 Si. Even up to high burnup rates (80% fifa) U 3 Si 2 was proved to be a reliable fuel that according to the test results achieved to date complies with all necessary requirements above all with respect to dimensional stability. U 3 Si showed significant changes of the fuel microstructure associated with considerably higher fuel swelling, that will probably exclude its use in research reactor operation. The irradiation of U 3 Si 1.3 and U 3 Si 1.5 plates had to be terminated untimely. Up to a burnup of 40% fifa these plates behaved quite well. An extrapolation to higher burnup rates, however only seems to be possible with reservations. (orig./HP) [de

  8. ^<90>Sr in mammal teeth taken in the Semipalatinsk Test Site measured by imaging plates

    OpenAIRE

    Toyoda, Shin; Pivovarov, Sergey; Hoshi, Masaharu; Seredavina, Tatyana

    2012-01-01

    The concentrations of 90Sr in mammal teeth taken in north-west part of Semipalatinsk Test Site were measured by using imaging plates. The highest concentration detected in the present study was 13Bq/g, being comparable with the values previously detected in cow teeth from South Ural region. It suggests that, at least locally, the soil in north-west part of the Test Site is possibly highly contaminated. It would be necessary to investigate the source of this high level of contamination, such a...

  9. Discrepancies in Weil-Felix and microimmunofluorescence test results for Rocky Mountain spotted fever.

    Science.gov (United States)

    Hechemy, K E; Stevens, R W; Sasowski, S; Michaelson, E E; Casper, E A; Philip, R N

    1979-01-01

    Only 4.2% of 284 single specimens and 17.6% of 51 pairs of sera reactive in Weil-Felix agglutination tests for Rocky Mountain spotted fever were confirmed by a specific Rickettsia rickettsii microimmunofluorescence test. PMID:107194

  10. Test and Numerical Analysis for Penetration Residual Velocity of Bullet Considering Failure Strain Uncertainty of Composite Plates

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Myungseok; Lee, Minhyung [Sejong Univ., Sejong (Korea, Republic of)

    2016-03-15

    The ballistic performance data of composite materials is distributed due to material inhomogeneity. In this paper, the uncertainty in residual velocity is obtained experimentally, and a method of predicting it is established numerically for the high-speed impact of a bullet into laminated composites. First, the failure strain distribution was obtained by conducting a tensile test using 10 specimens. Next, a ballistic impact test was carried out for the impact of a fragment-simulating projectile (FSP) bullet with 4ply ([0/90]s) and 8ply ([0/90/0/90]s) glass fiber reinforced plastic (GFRP) plates. Eighteen shots were made at the same impact velocity and the residual velocities were obtained. Finally, simulations were conducted to predict the residual velocities by using the failure strain distributions that were obtained from the tensile test. For this simulation, two impact velocities were chosen at 411.7m/s (4ply) and 592.5m/s (8ply). The simulation results show that the predicted residual velocities are in close agreement with test results. Additionally, the modeling of a composite plate with layered solid elements requires less calculation time than modeling with solid elements.

  11. Testing of multigap Resistive Plate Chambers for Electron Ion Collider Detector Development

    Science.gov (United States)

    Hamilton, Hannah; Phenix Collaboration

    2015-10-01

    Despite decades of research on the subject, some details of the spin structure of the nucleon continues to be unknown. To improve our knowledge of the nucleon spin structure, the construction of a new collider is needed. This is one of the primary goals of the proposed Electron Ion Collider (EIC). Planned EIC spectrometers will require good particle identification. This can be provided by time of flight (TOF) detectors with excellent timing resolutions of 10 ps. A potential TOF detector that could meet this requirement is a glass multigap resistive plate chamber (mRPC). These mRPCs can provide excellent timing resolution at a low cost. The current glass mRPC prototypes have a total of twenty 0.1 mm thick gas gaps. In order to test the feasibility of this design, a cosmic test stand was assembled. This stand used the coincidence of scintillators as a trigger, and contains fast electronics. The construction, the method of testing, and the test results of the mRPCs will be presented.

  12. Synthesis of Rh/Macro-Porous Alumina Over Micro-Channel Plate and Its Catalytic Activity Tests for Diesel Reforming.

    Science.gov (United States)

    Seong, Yeon Baek; Kim, Yong Sul; Park, No-Kuk; Lee, Tae Jin

    2015-11-01

    Macro-porous Al2O3 as the catalytic support material was synthesized using colloidal polystyrene spheres over a micro-channel plate. The colloidal polystyrene spheres were used as a template for the production of an ordered macro porous material using an alumina nitrate solution as the precursor for Al2O3. The close-packed colloidal crystal array template method was applied to the formulation of ordered macro-porous Al2O3 used as a catalytic support material over a micro-channel plate. The solvent in the mixture solution, which also contained the colloidal polystyrene solution, aluminum nitrate solution and the precursor of the catalytic active materials (Rh), was evaporated in a vacuum oven at 50 degrees C. The ordered polystyrene spheres and aluminum salt of the solid state were deposited over a micro channel plate, and macro-porous Al2O3 was formed after calcination at 600 degrees C to remove the polystyrene spheres. The catalytic activity of the Rh/macro-porous alumina supported over the micro-channel plate was tested for diesel reforming.

  13. Low-enriched uranium-molybdenum fuel plate development

    International Nuclear Information System (INIS)

    Wiencek, T.C.; Prokofiev, I.G.

    2000-01-01

    To examine the fabricability of low-enriched uranium-molybdenum powders, full-size 450 x 60 x 0.5-mm (17.7 x 2.4 x 0.020-in.) fuel zone test plates loaded to 6 g U/cm 3 were produced. U-10 wt.% Mo powders produced by two methods, centrifugal atomization and grinding, were tested. These powders were supplied at no cost to Argonne National Laboratory by the Korean Atomic Energy Research Institute and Atomic Energy of Canada Limited, respectively. Fuel homogeneity indicated that both of the powders produced acceptable fuel plates. Operator skill during loading of the powder into the compacting die and fuel powder morphology were found to be important when striving to achieve homogeneous fuel distribution. Smaller, 94 x 22 x 0.6-mm (3.7 x 0.87 x 0.025-in.) fuel zone, test plates were fabricated using U-10 wt.% Mo foil disks instead of a conventional powder metallurgy compact. Two fuel plates of this type are currently undergoing irradiation in the RERTR-4 high-density fuel experiment in the Advanced Test Reactor. (author)

  14. Comparison of BR3 Surveillance and Vessel Plates to the Surrogate Plates Representative of the Yankee Rowe PWR Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Fabry, A.; Chaouadi, R.; Puzzolante, J.L.; Van de Velde, J.; Biemiller, E.C.; Rosinski, S.T.; Carter, R.G

    1998-07-01

    The sister pressure vessels at the BR3 and Yankee Rowe PWR plants were operated at lower-than-usual temperature ( 260 degrees Celsius) and their plates were austenitized a higher-than-usual temperature (970 degrees Celsius) - a heat treatment leading to a coarser microstructure than is typical for the fine grain plates considered in development of USNRC Regulatory Guide 1.99. The surveillance programs provided by Westinghouse for the two plants were limited to the same A302-B plate representative of the Rowe vessel upper shell plate; this material displayed outlier behaviour characterized by a 41 J Charpy-V Notch shift significantly larger than predicted by Regulatory Guide 1.99. Because lower irradiation temperature and nickel alloying are generally considered detrimental to irradiation sensitivity, there was a major concern that the nickel-modified lower Rate plate and the nickel-modified BR3 plate may become too embrittled to satisfy the toughness requirements embodied in the PTS screening criterion. This paper compares free complementary studies undertaken to clarify these uncertainties: (1) The accelerated irradiation and test program launched in 1990 by Yankee Atomic Electric Company using typical vessel plate materials containing 0.24% copper at two nickel levels: YA1, 0.63 % (A533-B) and YA9, 0.19 (A302-B). These were heat-treated to produce the coarse and fine grain microstructures representative of the Yankee/BR3 and the Regulatory Guide plates, respectively; (2) The BR3 surveillance and vessel testing program: this vessel was wet-annealed in 1984, relicensed for operation till the plant shutdown in 1987, and was trepanned in early 1995; (3) The accelerated irradiations in the Belgian test reactor BR2 of the Yankee coarse grain plates YA1 and YA9 together with BR3 vessel specimens extracted at nozzle elevation, a location with negligible radiation exposure. It is contended that the PTS screening criterion was never attained by the BR3 and Rowe plates, and

  15. Comparison of BR3 Surveillance and Vessel Plates to the Surrogate Plates Representative of the Yankee Rowe PWR Vessel

    International Nuclear Information System (INIS)

    Fabry, A.; Chaouadi, R.; Puzzolante, J.L.; Van de Velde, J.; Biemiller, E.C.; Rosinski, S.T.; Carter, R.G.

    1998-07-01

    The sister pressure vessels at the BR3 and Yankee Rowe PWR plants were operated at lower-than-usual temperature ( 260 degrees Celsius) and their plates were austenitized a higher-than-usual temperature (970 degrees Celsius) - a heat treatment leading to a coarser microstructure than is typical for the fine grain plates considered in development of USNRC Regulatory Guide 1.99. The surveillance programs provided by Westinghouse for the two plants were limited to the same A302-B plate representative of the Rowe vessel upper shell plate; this material displayed outlier behaviour characterized by a 41 J Charpy-V Notch shift significantly larger than predicted by Regulatory Guide 1.99. Because lower irradiation temperature and nickel alloying are generally considered detrimental to irradiation sensitivity, there was a major concern that the nickel-modified lower Rate plate and the nickel-modified BR3 plate may become too embrittled to satisfy the toughness requirements embodied in the PTS screening criterion. This paper compares free complementary studies undertaken to clarify these uncertainties: (1) The accelerated irradiation and test program launched in 1990 by Yankee Atomic Electric Company using typical vessel plate materials containing 0.24% copper at two nickel levels: YA1, 0.63 % (A533-B) and YA9, 0.19 (A302-B). These were heat-treated to produce the coarse and fine grain microstructures representative of the Yankee/BR3 and the Regulatory Guide plates, respectively; (2) The BR3 surveillance and vessel testing program: this vessel was wet-annealed in 1984, relicensed for operation till the plant shutdown in 1987, and was trepanned in early 1995; (3) The accelerated irradiations in the Belgian test reactor BR2 of the Yankee coarse grain plates YA1 and YA9 together with BR3 vessel specimens extracted at nozzle elevation, a location with negligible radiation exposure. It is contended that the PTS screening criterion was never attained by the BR3 and Rowe plates, and

  16. Comparison of BR3 surveillance and vessel plates to the surrogate plates representative of the Yankee Rowe PWR vessel

    International Nuclear Information System (INIS)

    Fabry, A.; Chaouadi, R.; Puzzolante, J.L.; Van de Velde, J.; Biemiller, E.C.; Rosinski, S.T.; Carter, R.G.

    1999-01-01

    The sister pressure vessels at the BR3 and Yankee Rowe PWR plants were operated at lower-than-usual temperature (∼260 C) and their plates were austenitized at higher-than-usual temperature (∼970 C) -- a heat treatment leading to a coarser microstructure than is typical for the fine grain plates considered in development of USNRC Regulatory Guide 1.99. The surveillance programs provided by Westinghouse for the two plants were limited to the same A302-B plate representative of the Rowe vessel upper shell plate; this material displayed outlier behavior characterized by a 41J. Charpy-V Notch shift significantly larger than predicted by Regulatory Guide 1.99. Because lower irradiation temperature and nickel alloying are generally considered detrimental to irradiation sensitivity, there was a major concern that the nickel-modified lower Rowe plate and the nickel-modified BR3 plate may become too embrittled to satisfy the toughness requirements embodied in the PTS screening criterion. This paper compares three complementary studies undertaken to clarify these uncertainties: (1) The accelerated irradiation and test program launched in 1990 by Yankee Atomic Electric Company using typical vessel plate materials containing 0.24% copper at two nickel levels: YA1, 0.63% (A533-B) and YA9, 0.19% (A302-B). These were heat-treated to produce the coarse and fine grain microstructures representative of the Yankee/BR3 and the Regulatory Guide plates, respectively; (2) The BR3 surveillance and vessel testing program; this vessel was wet-annealed in 1984, relicensed for operation till the plant shutdown in 1987, and was trepanned in early 1995; (3) The accelerated irradiations in the Belgian test reactor BR2 of the Yankee coarse grain plates YA1 and YA9 together with BR3 vessel specimens extracted at nozzle elevation, a location with negligible radiation exposure. It is contended that the PTS screening criterion was never attained by the BR3 and Rowe plates, and that the BR3 vessel

  17. Requirements and testing methods for surfaces of metallic bipolar plates for low-temperature PEM fuel cells

    Science.gov (United States)

    Jendras, P.; Lötsch, K.; von Unwerth, T.

    2017-03-01

    To reduce emissions and to substitute combustion engines automotive manufacturers, legislature and first users aspire hydrogen fuel cell vehicles. Up to now the focus of research was set on ensuring functionality and increasing durability of fuel cell components. Therefore, expensive materials were used. Contemporary research and development try to substitute these substances by more cost-effective material combinations. The bipolar plate is a key component with the greatest influence on volume and mass of a fuel cell stack and they have to meet complex requirements. They support bending sensitive components of stack, spread reactants over active cell area and form the electrical contact to another cell. Furthermore, bipolar plates dissipate heat of reaction and separate one cell gastight from the other. Consequently, they need a low interfacial contact resistance (ICR) to the gas diffusion layer, high flexural strength, good thermal conductivity and a high durability. To reduce costs stainless steel is a favoured material for bipolar plates in automotive applications. Steel is characterized by good electrical and thermal conductivity but the acid environment requires a high chemical durability against corrosion as well. On the one hand formation of a passivating oxide layer increasing ICR should be inhibited. On the other hand pitting corrosion leading to increased permeation rate may not occur. Therefore, a suitable substrate lamination combination is wanted. In this study material testing methods for bipolar plates are considered.

  18. Relative range error evaluation of terrestrial laser scanners using a plate, a sphere, and a novel dual-sphere-plate target.

    Science.gov (United States)

    Muralikrishnan, Bala; Rachakonda, Prem; Lee, Vincent; Shilling, Meghan; Sawyer, Daniel; Cheok, Geraldine; Cournoyer, Luc

    2017-12-01

    Terrestrial laser scanners (TLS) are a class of 3D imaging systems that produce a 3D point cloud by measuring the range and two angles to a point. The fundamental measurement of a TLS is range. Relative range error is one component of the overall range error of TLS and its estimation is therefore an important aspect in establishing metrological traceability of measurements performed using these systems. Target geometry is an important aspect to consider when realizing the relative range tests. The recently published ASTM E2938-15 mandates the use of a plate target for the relative range tests. While a plate target may reasonably be expected to produce distortion free data even at far distances, the target itself needs careful alignment at each of the relative range test positions. In this paper, we discuss relative range experiments performed using a plate target and then address the advantages and limitations of using a sphere target. We then present a novel dual-sphere-plate target that draws from the advantages of the sphere and the plate without the associated limitations. The spheres in the dual-sphere-plate target are used simply as fiducials to identify a point on the surface of the plate that is common to both the scanner and the reference instrument, thus overcoming the need to carefully align the target.

  19. Experimental investigation of thermal limits in parallel plate configuration for the future material testing reactor (JHR)

    International Nuclear Information System (INIS)

    Brigitte Noel

    2005-01-01

    Full text of publication follows: The design of the future material testing reactor, named Jules Horowitz Reactor and dedicated to technological irradiations, will allow very high performances. The JHR will be cooled and moderated by light water. The preliminary core of JHR consists of 46 assemblies, arranged in a triangular lattice inside a rectangular aluminium matrix. It is boarded on two sides by a beryllium reflector. The other two sides are left free in order to introduce mobile irradiation devices. The JHR assembly would be composed of 3 x 6 cylindrical fuel plates maintained by 3 stiffeners. The external diameter of the assembly is close to 8 cm with a 600 mm heated length, coolant channels having a 1.8 mm gap width. The JHR core must be designed to accommodate high power densities using a high coolant mass flux and sub-cooling level at moderate pressure. The JHR core configuration with multi-channels is subject to a potential excursive instability, called flow redistribution, and is distinguished from a true critical heat flux which would occur at a fixed channel flow rate. At thermal-hydraulic conditions applicable to the JHR, the availability of experimental data for both flow redistribution and CHF is very limited. Consequently, a thermal-hydraulic test facility (SULTAN-RJH) was designed and built in CEA-Grenoble to simulate a full-length coolant sub-channel representative of the JHR core, allowing determination of both thermal limits under relevant thermal hydraulics conditions. The SULTAN-RJH test section simulates a single sub-channel in the JHR core with a cross section corresponding to a mean span (∼50 mm) that has a full reactor length (600 mm), the same flow channel gap (1.5 mm) and Inconel plates of 1 mm thickness. The tests with light water flowing vertically upward will investigate a heat flux range of 0-7 MW/m 2 , velocity range of 0.6-18 m/s, exit pressure range of 0.2-1.0 MPa and inlet temperature range of 25-180 deg. C. The test section

  20. Modeling particulate removal in plate-plate and wire-plate electrostatic precipitators

    Directory of Open Access Journals (Sweden)

    S Ramechecandane

    2016-09-01

    Full Text Available The present study is concerned with the modeling of electrically charged particles in a model plate-plate and a single wire-plate electrostatic precipitator (ESP. The particle concentration distributions for both a plate-plate and a wire-plate ESP are calculated using a modified drift flux model. Numerical investigations are performed using the modified drift flux model for particle number concentration, in addition to the RNG k - ε model for the mean turbulent flow field and the Poisson equation for the electric field. The proposed model and the outlined methodology for coupling the flow field, electric field, charging kinetics and particle concentration is applied to two model precipitators that are truly representative of a wide class of commercialized ESPs. The present investigation is quite different from the earlier studies as it does not make assumptions like a homogeneous electric field or an infinite turbulent diffusivity. The electric field calculated is a strong function of position and controls the migration velocity of particles. Hence, the proposed model can be implemented in a flow solver to obtain a full-fledged solution for any kind of ESP with no limitations on the particle number concentration, as encountered in a Lagrangian approach. The effect of turbulent diffusivity on particle number concentration in a plate-plate ESP is investigated in detail and the results obtained are compared with available experimental data. Similarly, the effect of particle size/diameter and applied electric potential on the accumulative collection performance in the case of a wire-plate ESP is studied and the results obtained are compared with available numerical data. The numerical results obtained using the modified drift flux model for both the plate-plate and wire-plate ESP are in close agreement with available experimental and numerical data.

  1. Implementation of the non-destructive ultrasound testing by immersion through the transmission technique, applied to the quality control of nuclear fuel plates

    International Nuclear Information System (INIS)

    Medina Jofre, David Christian

    2014-01-01

    Within the framework of global development, which seeks to reduce the enrichment of U 235 in nuclear fuels for research reactors, the Fuel Elements Plant (PEC) of the Chilean Nuclear Energy Commission (CCHEN) has worked with the Idaho National Laboratory (INL-USA), for the fabrication of high density fuel plates based on the dispersion of Uranium-Molybdenum alloy powders (UMo), which are subjected to inspections and tests to qualify as a compliant product for use in nuclear research reactors. It is in this matter where the Non Destructive Test (NDT) of immersion ultrasound used in both facilities differs in its acceptance criteria, when is used different testing techniques; On the one hand, the PEC uses the pulse-echo technique, while the INL uses the transmission technique. Therefore, the present work is focused on the implementation of the ultrasound by immersion using the transmission technique. During the development of the work, the physical and virtual configuration of the ultrasound equipment was possible and elaborate an operation procedure, which allows to inspect through this technique, a series of fuel plates based on UMo and U 3 Si 2 powders, with different characteristics. The results allow to characterize the signals obtained in fuel plates according to the nuclear fuel material used. There is an inverse relationship between the uranium load per unit volume (uranium density, gU/cm 3 ) used in the fuel plate and the transmittance of the ultrasonic beam through the areas where there is nuclear fuel material (meat); the effect produced by a dispersed combustible material is observed and it is possible to identify discontinuities that may be present in the fuel plate. Finally, an inspection technical instruction for U 3 Si 2 fuel plates is elaborated, where acceptance and rejection criteria are defined

  2. Lead plating of the low beta resonator

    International Nuclear Information System (INIS)

    Brennan, J.M.; Corcoran, D.; Coughlin, R.; Goliak, T.; Hodgkins, D.; James, P.; Seamster, A.G.; Secora, J.H.

    1984-01-01

    Plating operations were performed at the lead plating facility at SUNY, Stony Brook. Initial procedures were based on the previous experience of prototype development by Ben-Zvi and Brennan. Several attempts were made to produce satisfactory results, however the lead surfaces were consistently stained and lacked the bright metallic finish routinely achieved with the split loop resonator at SUNY. The development of a new set of procedures was initiated, aided by reports of plating success from Ben-Zvi. Controlled tests were conducted which suggested several changes in the plating parameters. Based on these results and suggestions from the staff at SUNY a new process was defined which was successful in producing the smooth reflective metallic surface known to be necessary forla optimum resonator performance. Following a successful repair of the the crack, the prototype was plated and chemically polished with the new techniques. The resultant surface was highly reflective and free of stains and particulates. The subsequent prototype cold test was successful

  3. The false sero-negativity of brucella standard agglutination test: Prozone phenomenon

    Directory of Open Access Journals (Sweden)

    İrfan Binici

    2011-12-01

    Full Text Available Objectives: We aimed to assess prozone phenomenon that is quite rare and causes false negativity in serological diagnosisof brucellosis with standard dilution titers.Materials and methods: In this study the tests of four cases that have false negative serological results were evaluated.Blood cultures were obtained from all cases while cerebrospinal fluid cultures were studied in the two cases. Standardagglutination test (SAT and Coombs test were performed to all patients.Results: SAT and Coombs test was negative in titers up to 1/640 in all cases. The SAT and Coombs tests in cerebrospinalfluid (CSF of the two cases with neurobrucellosis diagnosis were negative, as well. Since the clinical and laboratoryfindings suggested the brucellosis, the serums were restudied by diluting up to 1/10240 titer and we saw that the first3 cases became positive at a titer of 1/1280. The fourth case remained negative and therefore, we applied high dilutionCoombs test. This time the test gave a positive result at 1/10240 titer beginning from 1/2560 titer. B.melitensis wasisolated from two cases.Conclusion: SAT and Coombs’ test must be diluted to titers 1/2560 or more in order to exclude false sero-negativity incases with clinical and laboratory findings suggesting brucellosis. J Microbiol Infect Dis 2011; 1(3:110-113

  4. Analysis of the discontinuous Petrov-Galerkin method with optimal test functions for the Reissner-Mindlin plate bending model

    KAUST Repository

    Calo, Victor M.; Collier, Nathan; Niemi, Antti H.

    2014-01-01

    We analyze the discontinuous Petrov-Galerkin (DPG) method with optimal test functions when applied to solve the Reissner-Mindlin model of plate bending. We prove that the hybrid variational formulation underlying the DPG method is well-posed (stable

  5. The use of U3Si2 dispersed in aluminum in plate-type fuel elements for research and test reactors

    International Nuclear Information System (INIS)

    Snelgrove, J.L.; Domagala, R.F.; Hofman, G.L.; Wiencek, T.C.; Copeland, G.L.; Hobbs, R.W.; Senn, R.L.

    1987-10-01

    A high-density fuel based on U 3 Si 2 dispersed in aluminum has been developed and tested for use in converting plate-type research and test reactors from the use of highly enriched uranium to the use of low-enriched uranium. Results of preirradiation testing and the irradiation and postirradiation examination of miniature fuel plates and full-sized fuel elements are summarized. Swelling of the U 3 Si 2 fuel particles is a linear function of the fission density in the particle to well beyond the fission density achievable in low-enriched fuels. U 3 Si 2 particle swelling rate is approximately the same as that of the commonly used UAl/sub x/ fuel particle. The presence of minor amounts of U 3 Si or uranium solid solution in the fuel result in greater, but still acceptable, fuel swelling. Blister threshold temperatures are at least as high as those of currently used fuels. An exothermic reaction occurs near the aluminum melting temperature, but the measured energy releases were low enough not to substantially worsen the consequences of an accident. U 3 Si 2 -aluminum dispersion fuel with uranium densities up to at least 4.8 Mg/m 3 is a suitable LEU fuel for typical plate-type research and test reactors. 42 refs., 28 figs., 7 tabs

  6. Simulation analysis of impact tests of steel plate reinforced concrete and reinforced concrete slabs against aircraft impact and its validation with experimental results

    International Nuclear Information System (INIS)

    Sadiq, Muhammad; Xiu Yun, Zhu; Rong, Pan

    2014-01-01

    Highlights: • Simulation analysis is carried out with two constitutive concrete models. • Winfrith model can better simulate nonlinear response of concrete than CSCM model. • Performance of steel plate concrete is better than reinforced concrete. • Thickness of safety related structures can be reduced by adopting steel plates. • Analysis results, mainly concrete material models should be validated. - Abstract: The steel plate reinforced concrete and reinforced concrete structures are used in nuclear power plants for protection against impact of an aircraft. In order to compare the impact resistance performance of steel plate reinforced concrete and reinforced concrete slabs panels, simulation analysis of 1/7.5 scale model impact tests is carried out by using finite element code ANSYS/LS-DYNA. The damage modes of all finite element models, velocity time history curves of the aircraft engine and damage to aircraft model are compared with the impact test results of steel plate reinforced concrete and reinforced concrete slab panels. The results indicate that finite element simulation results correlate well with the experimental results especially for constitutive winfrith concrete model. Also, the impact resistance performance of steel plate reinforced concrete slab panels is better than reinforced concrete slab panels, particularly the rear face steel plate is very effective in preventing the perforation and scabbing of concrete than conventional reinforced concrete structures. In this way, the thickness of steel plate reinforced concrete structures can be reduced in important structures like nuclear power plants against impact of aircraft. It also demonstrates the methodology to validate the analysis procedure with experimental and analytical studies. It may be effectively employed to predict the precise response of safety related structures against aircraft impact

  7. Create Your Plate

    Medline Plus

    Full Text Available ... Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ... Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart- ...

  8. Create Your Plate

    Medline Plus

    Full Text Available ... Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ... Planning Meals Diabetes Meal Plans and a Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets ...

  9. Test and characterization of multigap resistive plate chambers for the EEE project

    CERN Document Server

    Bossini, E

    2016-01-01

    The Extreme Energy Events project is based on the deployment of cosmic-ray telescopes in Italian high schools with the active contribution of students and teachers. Each telescope is made by three Multigap Resistive Plate Chambers readout by strips. With around 50 telescopes already built and others under construction, specific systems to test and characterize the chambers are needed. In this article I will present a flexible and software-configurable solution to perform chamber efficiency studies with a set of scintillators and hardware to automatically scan detector strips to identify electrical issues. Both systems can provide accurate information but at the same time they can be easily operated by students.

  10. Comparison of conventional reconstruction plate versus direct metal laser sintering plate: an in vitro mechanical characteristics study.

    Science.gov (United States)

    Xie, Pusheng; Ouyang, Hanbin; Deng, Yuping; Yang, Yang; Xu, Jing; Huang, Wenhua

    2017-09-02

    Additive manufacturing (AM) technology has helped to achieve several advances in the medical field, particularly as far as fabrication of implants is concerned. But the application of direct metal laser sintering (DMLS) bone plate is quite limited due to the indeterminate mechanical property. The purposes of this study were to characterize the biomechanical properties of the polished DMLS reconstruction plate and to compare these with the properties of commonly applied implants and to find whether the mechanical performance of DMLS plate meets the requirements for clinical application. In this study, we fabricated two groups of plates by DMLS and computer numerical control (CNC) techniques. After that, we polished all samples and investigated their roughness, components, hardness, static bending, and torsional performance. Moreover, cyclic bending tests and fractographic analysis were conducted. Statistical comparisons of the group by means of monotonic test data were made, and a qualitative comparison was performed to assess failures in fatigue. We found no differences in surface roughness or components after polishing, but the DMLS plate hardness is 7.42% (p direct application of these AM instruments in the operating room requires further validation including animal and clinical experiment.

  11. 115 THE SENSITIVITY OF DIAZO TEST IN THE DIAGNOSIS OF ...

    African Journals Online (AJOL)

    Salmonella typhi was the predominant serotype causing typhoid/paratyphoid fevers, followed by S. paratypi A; S. paratyphi C and S. paratyphi B respectively. Although. Diazo test does not appear to be reliable, it could still be useful alongside with Widal agglutination test in endemic rural or urban areas where electricity and ...

  12. Evaluation of Electroless-Nickel Plated Polypropylene under Thermal Cycling and Mechanical Tests

    Directory of Open Access Journals (Sweden)

    O.O. Ajibola

    2016-09-01

    Full Text Available The electroless-nickel composite (ENC consisting of bright metallic electroless-nickel (EN and dull electroless-nickel-phosphorus (EN-P were deposited on the polypropylene (PP substrate from the sodium hypophosphite baths. The ENC plated specimens were subjected to abrasive wear-adhesion test of 1750, 3500, 7000 and 14000 cycles; thermal cycle-adhesion tests, and tensile strength and creep tests. The deposition of ENC influenced the strength and creep strain properties of the PP. The maximum stress σ of 118 (MPa was obtained from EN-PP specimen at strain  of 0.1 mm/mm as compared with the PP having stress σ of 36 (MPa at strain  of 0.07 mm/mm before failure The surface appearances and microstructures of ENC film on PP substrates were examined under the higher resolution metallurgical microscope with digital camera and microscopic camera. The composition of ENC film was characterized using Scanning Electron Microscopy and Energy Dispersive X-Ray analyses (Jeol JSM-7600F Field Emission SEM/EDX, The micrographs and spectra lines data generated were used to interpret the results.

  13. LEPINOCONUS CHIOCCHINII GEN. N., N. SP., A CONICAL AGGLUTINATED FORAMINIFERA FROM THE UPPER CRETACEOUS OF ITALY

    Directory of Open Access Journals (Sweden)

    ERZIKA CRUZ-ABAD

    2017-04-01

    Full Text Available A new conical agglutinated foraminifer, Lepinoconus chiocchinii gen n., n. sp. from the lower Campanian shallow-water platform deposits of the Lepini Mountains (central Apennines, Italy, is described. It has a pseudo-keriothecal wall structure, uniserial arrangement of the adult chambers and multiple apertures. The exoskeleton is constituted by beams (main and intercalary continuous from one chamber to the next, while the endoskeleton bears pillars. The new taxon is included in the Coskinolinidae family. Lepinoconus chiocchinii gen. n., n. sp. is known from southern Italy, Greece and Albania.

  14. White Light Photorefractive Phase Zone Plates

    International Nuclear Information System (INIS)

    Yuan-Mei, Gao; Si-Min, Liu

    2008-01-01

    Incoherent white light from an incandescent source is employed to fabricate volume phase zone plates in LiNbO 3 : Fe, for the first time to our knowledge, which can guide and modulate the input white light or laser light. The diffractive efficiency of the white light volume phase zone plates fabricated can reach as high as 12%. In addition, we test the volume phase zone plates by a probe beam and find that the volume phase zone plate is present in the direction perpendicular to the c-axis and absent in the direction parallel to the c-axis. This directly proves the existence of photovoltaic photorefractive anisotropy of white light

  15. Base-plate effects on pipe-support stiffness

    International Nuclear Information System (INIS)

    Winkel, B.V.; LaSalle, F.R.

    1981-01-01

    Present nuclear power plant design methods require that pipe support spring rates be considered in the seismic design of piping systems. Base plate flexibility can have a significant effect on the spring rates of these support structures. This paper describes the field inspection, test, and analytical techniques used to identify and correct excessively flexible base plates on the Fast Flux Test Facility pipe support structures

  16. A repA-based ELISA for discriminating cattle vaccinated with Brucella suis 2 from those naturally infected with Brucella abortus and Brucella melitensis.

    Science.gov (United States)

    Wang, Jing-Yu; Wu, Ning; Liu, Wan-Hua; Ren, Juan-Juan; Tang, Pan; Qiu, Yuan-Hao; Wang, Chi-Young; Chang, Ching-Dong; Liu, Hung-Jen

    2014-01-01

    The commonest ways of diagnosing brucellosis in animals include the Rose-Bengal plate agglutination test, the buffered plate agglutination test (BPA), the slide agglutination test, the complement fixation test, and the indirect enzyme linked immunosorbent assay (I-ELISA). However, these methods cannot discriminate the Brucella vaccine strain (Brucella suis strain 2; B. suis S2) from naturally acquired virulent strains. Of the six common Brucella species, Brucella melitensis, Brucella abortus, and B. suis are the commonest species occurring in China. To develop an ELISA assay that can differentiate between cows inoculated with B. suis S2 and naturally infected with B. abortus and B. melitensis, genomic sequences from six Brucella spp. (B. melitensis, B. abortus, B. suis, Brucella canis, Brucella neotomae and Brucella ovis) were compared using Basic Local Alignment Search Tool software. One particular gene, the repA-related gene, was found to be a marker that can differentiate B. suis from B. abortus and B. melitensis. The repA-related gene of B. suis was PCR amplified and subcloned into the pET-32a vector. Expressed repA-related protein was purified and used as an antigen. The repA-based ELISA was optimized and used as specific tests. In the present study, serum from animals inoculated with the B. suis S2 vaccine strain had positive repA-based ELISA results. In contrast, the test-positive reference sera against B. abortus and B. melitensis had negative repA-based ELISA results. The concordance rate between B. abortus antibody-negative (based on the repA-based ELISA) and the Brucella gene-positive (based on the 'Bruce ladder' multiplex PCR) was 100%. Therefore, the findings suggest that the repA-based ELISA is a useful tool for differentiating cows vaccinated with the B. suis S2 and naturally infected with B. abortus and B. melitensis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Standarized performance tests of collectors of solar thermal energy: A steel flat-plate collector with two transparent covers and a proprietary coating

    Science.gov (United States)

    1976-01-01

    Basic test results of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator are given. The collector was tested over ranges of inlet temperature and flux level.

  18. Fatigue test results of flat plate specimens with surface cracks and evaluation of crack growth in structural components

    International Nuclear Information System (INIS)

    Shibata, Katsuyuki; Yokoyama, Norio; Ohba, Toshihiro; Kawamura, Takaichi; Miyazono, Shohachiro

    1982-12-01

    Part-through surface cracks are most frequently observed in the inspection of structural components, and it is one of the important subjects in the assessment of safety to evaluate appropriately the growth of such cracks during the service life of structural components. Due to the complexity of the stress at the front free surface, the crack growth at the surface shows a different behavior from the other part. Besides, an effect of interaction is caused in the growth of multiple surface cracks. These effects should be included in the growth analysis of surface part-through cracks. Authors have carried out a series of fatigue tests on some kinds of pipes with multiple cracks in the inner surface, and subsequently the fatigue test of flat plate specimens, made of Type 304L stainless steel, with a single or double surface cracks was carried out to study the basic characteristics in the growth of multiple surface cracks. Based on the results of the flat plate test. the correction factors for the front free surface (Cs) and interaction (Ci) of surface cracks were derived quantitatively by the following empirical expressions; Cs = 0.824. Ci = (0.227(a/b) 2 (sec(PI X/2) - 1) + 1)sup(1/m). Using these two correction factors, a procedure to predict the growth of surface cracks was developed by applying the crack growth formula to both the thickness and surface directions. Besides, the crack growth predictions based on the procedure of ASME Code Sex. XI, and the above procedure without the correction of the free surface and interactions on the crack growth behaviors were compared with the test results of flat plate specimens. The crack growth behavior predicted by the procedure described in this report showed the best agreement with the test results in respects of the crack growth life and the change in the crack shape. The criteria of the ASME Code did not agree with the test results. (author)

  19. Corrosion Behavior of Nickel-Plated Alloy 600 in High Temperature Water

    International Nuclear Information System (INIS)

    Kim, Ji Hyun; Hwang, Il Soon

    2008-01-01

    In this paper, electrochemical and microstructural characteristics of nickel-plated Alloy 600 wee investigated in order to identify the performance of electroless Ni-plating on Alloy 600 in high-temperature aqueous condition with the comparison of electrolytic nickel-plating. For high temperature corrosion test of nickel-plated Alloy 600, specimens were exposed for 770 hours to typical PWR primary water condition. During the test, open circuit potentials (OCP's) of all specimens were measured using a reference electrode. Also, resistance to flow accelerated corrosion (FAC) test was examined in order to check the durability of plated layers in high-velocity flow environment at high temperature. After exposures to high flow rate aqueous condition, the integrity of surfaces was confirmed by using both scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). For the field application, a remote process for electroless nickel-plating was demonstrated using a plate specimen with narrow gap on a laboratory scale. Finally, a practical seal design was suggested for more convenient application

  20. Hydrodynamics of a flexible plate between pitching rigid plates

    Science.gov (United States)

    Kim, Junyoung; Kim, Daegyoum

    2017-11-01

    The dynamics of a flexible plate have been studied as a model problem in swimming and flying of animals and fluid-structure interaction of plants and flags. Motivated by fish schooling and an array of sea grasses, we investigate the dynamics of a flexible plate closely placed between two pitching rigid plates. In most studies on passive deformation of the flexible plate, the plate is immersed in a uniform flow or a wavy flow. However, in this study, the flexible plate experiences periodic deformation by the oscillatory flow generated by the prescribed pitching motion of the rigid plates. In our model, the pitching axes of the rigid plates and the clamping position of the flexible plate are aligned on the same line. The flexible plate shows various responses depending on length and pitching frequency of rigid plates, thickness of a flexible plate, and free-stream velocity. To find the effect of each variable on the response of the flexible plate, amplitude of a trailing edge and modal contribution of a flapping motion are compared, and flow structure around the flexible plate is examined.

  1. Lectin-induced agglutination method of urinary exosomes isolation followed by mi-RNA analysis: Application for prostate cancer diagnostic.

    Science.gov (United States)

    Samsonov, Roman; Shtam, Tatiana; Burdakov, Vladimir; Glotov, Andrey; Tsyrlina, Evgenia; Berstein, Lev; Nosov, Alexander; Evtushenko, Vladimir; Filatov, Michael; Malek, Anastasia

    2016-01-01

    Prostate cancer is the most common cancer in men. Prostate-specific antigen has, however, insufficient diagnostic specificity. Novel complementary diagnostic approaches are greatly needed. MiRNAs are small regulatory RNAs which play an important role in tumorogenesis and are being investigated as a cancer biomarker. In addition to their intracellular regulatory functions, miRNAs are secreted into the extracellular space and can be found in various body fluids, including urine. The stability of extracellular miRNAs is defined by association with proteins, lipoprotein particles, and membrane vesicles. Among the known forms of miRNA packaging, tumour-derived exosome-enclosed miRNAs is thought to reflect the vital activity of cancer cells. The assessment of the exosomal fraction of urinary miRNA may present a new and highly specific method for prostate cancer diagnostics; however, this is challenged by the absence of reliable and inexpensive methods for isolation of exosomes. Prostate cancer (PC) cell lines and urine samples collected from 35 PC patients and 35 healthy donors were used in the study. Lectins, phytohemagglutinin, and concanavalin A were used to induce agglutination of exosomes. The efficiency of isolation process was evaluated by AFM and DLS assays. The protein content of isolated exosomes was analysed by western blotting. Exosomal RNA was assayed by automated electrophoresis and expression level of selected miRNAs was evaluated by RT-qPCR. The diagnostic potency of the urinary exosomal miRNA assessment was estimated by the ROC method. The formation of multi-vesicular agglutinates in urine can be induced by incubation with lectin at a final concentration of 2 mg/ml. These agglutinates contain urinary exosomes and may be pelleted by centrifugation with a relatively low G-force. The analysis of PC-related miRNA in urinary exosomes revealed significant up-regulation of miR-574-3p, miR-141-5p, and miR-21-5p associated with PC. Lectin-induced aggregation is a

  2. Rapid serum agglutination and agar gel immunodiffusion tests associated to clinical signs in rams experimentally infected with Brucella ovis Teste de soro aglutinação rápida e do teste de imunodifusão em gel de ágar associados aos sinais clínicos em carneiros infectados experimentalmente com Brucella ovis

    Directory of Open Access Journals (Sweden)

    Cristiane Nakada Nozaki

    2011-08-01

    Full Text Available The purpose of this study was to evaluate the agar gel immunodiffusion and the rapid serum agglutination tests associated to clinical signs in rams experimentally infected with Brucella ovis. The serological profile during the 12 months of infection showed a large fluctuation of antibodies that favors the failure in the diagnostic. The evaluation of tests after the experimental infection allowed to suggest that none of the tests were able to detect the infection throughout the period of study. The study reinforces the importance of considering the clinical signs to support the diagnosis of Brucella ovis infection in rams.O objetivo deste estudo foi avaliar o uso do teste de imunodifusão em gel de ágar e o teste sorológico de aglutinação rápida comparados aos sinais clínicos em carneiros infectados experimentalmente com Brucella ovis para o diagnóstico confirmatório da brucelose ovina. O perfil sorológico durante os 12 meses pós-infecção mostrou flutuação da resposta por anticorpos, que favorece a falha no diagnóstico. A avaliação dos testes indicou que nenhum dos testes foi capaz de detectar a infecção durante todo o período de estudo. O estudo ressalta a importância de considerar os sinais clínicos para apoiar o diagnóstico confirmatório da infecção por Brucella ovis em carneiros.

  3. An unusual presentation of brucellosis, involving multiple organ systems, with low agglutinating titers: a case report

    Directory of Open Access Journals (Sweden)

    Khorvash Farzin

    2007-07-01

    Full Text Available Abstract Background Brucellosis is a multi-system disease that may present with a broad spectrum of clinical manifestations. While hepatic involvement in brucellosis is not rare, it may rarely involve the kidney or display with cardiac manifestations. Central nervous system involvement in brucellosis sometimes can cause demyelinating syndromes. Here we present a case of brucella hepatitis, myocarditis, acute disseminated encephalomyelitis, and renal failure. Case presentation A 26-year-old man presented with fever, ataxia, and dysarthria. He was a shepherd and gave a history of low grade fever, chilly sensation, cold sweating, loss of appetite, arthralgia and 10 Kg weight loss during the previous 3 months. He had a body temperature of 39°C at the time of admission. On laboratory tests he had elevated level of liver enzymes, blood urea nitrogen, Creatinine, Creatine phosphokinase (MB, and moderate proteinuria. He also had abnormal echocardiography and brain MRI. Enzyme-linked immunosorbent assay for IgG and IgM was negative. Standard tube agglutination test (STAT and 2-mercaptoethanol (2-ME titers were 1:80 and 1:40 respectively. Finally he was diagnosed with brucellosis by positive blood culture and the polymerase chain reaction for Brucella mellitensis. Conclusion In endemic areas clinicians should consider brucellosis in any unusual presentation involving multiple organ systems, even if serology is inconclusive. In endemic areas low STAT and 2-ME titers should be considered as an indication of brucellosis and in these cases additional testing is recommended to rule out brucellosis.

  4. Optimization of geometrical characteristics of perforated plates

    International Nuclear Information System (INIS)

    Radisavljevic, Igor; Balos, Sebastian; Nikacevic, Milutin; Sidjanin, Leposava

    2013-01-01

    Highlights: ► Perforated plate are tested against 12.7 mm API projectile. ► Perforations similar to the projectile diameter offer more efficient core fracture. ► Larger perforations gave a more efficient core fragmentation. ► SEM microscopy analysis has shown a ductile fracture mode at impact point. - Abstract: In this paper, an attempt was made to design effective non-homogenous armor in form of perforated plate mounted at close distance from basic armor plate. Perforated plate with three perforation diameters: 9, 10 and 11 mm, two ligaments length: 3.5 and 4.5 mm ligaments, set at 0° and 28° angles, were combined to 13 mm basic plate and tested against 12.7 mm API ammunition. It has been shown that larger perforations gave a more efficient core fragmentation, while angled specimens were the only ones that offer full protection against five API shots when the perforated plate was placed at 100 mm from the basic plate. Perforations that are similar in size to the penetrating core diameter offer a more efficient core fracture, leading to a faster fragment separation. This may enable a smaller distance between the add-on perforated and basic plate to be used. Scanning electron microscopy analysis has shown a ductile fracture mode at impact point, with hardness values on plate basic level. On the other hand, a brittle fracture mode with a rise in local hardness measured near impact point is a result of intensive high speed plastic deformation produced by bending stresses. A drop in local hardness measured near impact point, may be the result of intensive cracking that occur due to repeated projectile impact

  5. Failure analysis of stainless steel femur fixation plate.

    Science.gov (United States)

    Hussain, P B; Mohammad, M

    2004-05-01

    Failure analysis was performed to investigate the failure of the femur fixation plate which was previously fixed on the femur of a girl. Radiography, metallography, fractography and mechanical testing were conducted in this study. The results show that the failure was due to the formation of notches on the femur plate. These notches act as stress raisers from where the cracks start to propagate. Finally fracture occurred on the femur plate and subsequently, the plate failed.

  6. Standardized performance tests of collectors of solar thermal energy-a flat-plate collector with a single-tube serpentine flow distribution

    Science.gov (United States)

    Johnson, S.

    1976-01-01

    This preliminary data report gives basic test results of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and coolant flow rates. Collector efficienty is correlated in terms of inlet temperature and flux level.

  7. A Constitutively Mannose-Sensitive Agglutinating Salmonella enterica subsp. enterica Serovar Typhimurium Strain, Carrying a Transposon in the Fimbrial Usher Gene stbC, Exhibits Multidrug Resistance and Flagellated Phenotypes

    Directory of Open Access Journals (Sweden)

    Kuan-Hsun Wu

    2012-01-01

    Full Text Available Static broth culture favors Salmonella enterica subsp. enterica serovar Typhimurium to produce type 1 fimbriae, while solid agar inhibits its expression. A transposon inserted in stbC, which would encode an usher for Stb fimbriae of a non-flagellar Salmonella enterica subsp. enterica serovar Typhimurium LB5010 strain, conferred it to agglutinate yeast cells on both cultures. RT-PCR revealed that the expression of the fimbrial subunit gene fimA, and fimZ, a regulatory gene of fimA, were both increased in the stbC mutant when grown on LB agar; fimW, a repressor gene of fimA, exhibited lower expression. Flagella were observed in the stbC mutant and this phenotype was correlated with the motile phenotype. Microarray data and RT-PCR indicated that the expression of three genes, motA, motB, and cheM, was enhanced in the stbC mutant. The stbC mutant was resistant to several antibiotics, consistent with the finding that expression of yhcQ and ramA was enhanced. A complementation test revealed that transforming a recombinant plasmid possessing the stbC restored the mannose-sensitive agglutination phenotype to the stbC mutant much as that in the parental Salmonella enterica subsp. enterica serovar Typhimurium LB5010 strain, indicating the possibility of an interplay of different fimbrial systems in coordinating their expression.

  8. MTR fuel plate qualification capabilities at SCK-CEN

    International Nuclear Information System (INIS)

    Koonen, E.; Jacquet, P.

    2002-01-01

    In order to enhance the capabilities of BR2 in the field of MTR fuel plate testing, a dedicated irradiation device has been designed. In its basic version this device allows the irradiation of 3 fuel plates. The central fuel plate may be replaced by a dummy plate or a plate carrying dosimeters. A first FUTURE device has been built. A benchmark irradiation has been executed with standard BR2 fuel plates in order to qualify this device. Detailed neutronic calculations were performed and the results compared to the results of the post-irradiation examinations of the plates. These comparisons demonstrate the capability to conduct a fuel plate irradiation program under requested and well-known irradiation conditions. Further improvements are presently being designed in order to extend the ranges of heat flux and surface temperature of the fuel plates that can be handled with the FUTURE device. (author)

  9. Condensation heat transfer in plate heat exchangers

    International Nuclear Information System (INIS)

    Panchal, C.B.

    1985-01-01

    An Alfa-Laval plate heat exchanger, previously tested as an evaporator, was retested as a condenser. Two series of tests with different chevron-angle plates were carried out using ammonia as a working fluid. The overall heat-transfer coefficient and pressure drop were measured, and the effects of operating parameters were determined. The experimental data were compared with theoretical predictions. In the analysis, a gravity-controlled condensation process was modeled theoretically, and the overall performance was calculated. The analysis shows that the overall heat-transfer coefficient can be predicted with an average uncertainty of about 10%. It is, however, important to consider the interfacial shear stress, because the effective friction factor is high for flow in plate heat exchangers

  10. Plate tectonics in the late Paleozoic

    Directory of Open Access Journals (Sweden)

    Mathew Domeier

    2014-05-01

    Full Text Available As the chronicle of plate motions through time, paleogeography is fundamental to our understanding of plate tectonics and its role in shaping the geology of the present-day. To properly appreciate the history of tectonics—and its influence on the deep Earth and climate—it is imperative to seek an accurate and global model of paleogeography. However, owing to the incessant loss of oceanic lithosphere through subduction, the paleogeographic reconstruction of ‘full-plates’ (including oceanic lithosphere becomes increasingly challenging with age. Prior to 150 Ma ∼60% of the lithosphere is missing and reconstructions are developed without explicit regard for oceanic lithosphere or plate tectonic principles; in effect, reflecting the earlier mobilistic paradigm of continental drift. Although these ‘continental’ reconstructions have been immensely useful, the next-generation of mantle models requires global plate kinematic descriptions with full-plate reconstructions. Moreover, in disregarding (or only loosely applying plate tectonic rules, continental reconstructions fail to take advantage of a wealth of additional information in the form of practical constraints. Following a series of new developments, both in geodynamic theory and analytical tools, it is now feasible to construct full-plate models that lend themselves to testing by the wider Earth-science community. Such a model is presented here for the late Paleozoic (410–250 Ma together with a review of the underlying data. Although we expect this model to be particularly useful for numerical mantle modeling, we hope that it will also serve as a general framework for understanding late Paleozoic tectonics, one on which future improvements can be built and further tested.

  11. Research on metal-plated cellulose nitrate flakes and their infrared / millimeter wave characteristics

    Science.gov (United States)

    Ye, Shu-qin; Zhu, Chen-guang; Wang, Li-hong; Ou'yang, De-hua; Pan, Gong-pei

    2016-10-01

    Copper-plated and silver-plated cellulose nitrate flakes, which were prepared by using chemical plating technology, were used to jam infrared detector and millimeter-wave radar. It was tested for the conductivity and infrared jamming performance of plating and also the RCS (Radar Cross Section) performance of millimeter-wave radar. Test results showed that the prepared metal-plated cellulose nitrate flakes have obvious conductivity, and infrared total radiation energy of silver plating and copper plating had approximately increased 32% and 21% respectively. Through determination, the millimeter-wave reflecting property and RCS of silver-plated cellulose nitrate flakes were higher than that of copper-plated cellulose nitrate flakes. Therefore, silver-plated cellulose nitrate flakes can be used as an effective infrared / millimeter wave composite jamming material.

  12. Genetic and mechanistic evaluation for the mixed-field agglutination in B3 blood type with IVS3+5G>A ABO gene mutation.

    Directory of Open Access Journals (Sweden)

    Ding-Ping Chen

    Full Text Available BACKGROUND: The ABO blood type B(3 is the most common B subtype in the Chinese population with a frequency of 1/900. Although IVS3+5G>A (rs55852701 mutation of B gene has been shown to associate with the development of B(3 blood type, genetic and mechanistic evaluation for the unique mixed-field agglutination phenotype has not yet been completely addressed. METHODOLOGY/PRINCIPAL FINDINGS: In this study, we analyzed 16 cases of confirmed B(3 individuals and found that IVS3+5G>A attributes to all cases of B(3. RT-PCR analyses revealed the presence of at least 7 types of aberrant B(3 splicing transcripts with most of the transcripts causing early termination and producing non-functional protein during translation. The splicing transcript without exon 3 that was predicted to generate functional B(3 glycosyltransferase lacking 19 amino acids at the N-terminal segment constituted only 0.9% of the splicing transcripts. Expression of the B(3 cDNA with exon 3 deletion in the K562 erythroleukemia cells revealed that the B(3 glycosyltransferase had only 40% of B(1 activity in converting H antigen to B antigen. Notably, the typical mixed-field agglutination of B(3-RBCs can be mimicked by adding anti-B antibody to the K562-B(3 cells. CONCLUSIONS/SIGNIFICANCE: This study thereby demonstrates that both aberrant splicing of B transcripts and the reduced B(3 glycosyltransferase activity contribute to weak B expression and the mixed-field agglutination of B(3, adding to the complexity for the regulatory mechanisms of ABO gene expression.

  13. Flaw behavior in mechanically loaded clad plates

    International Nuclear Information System (INIS)

    Iskander, S.K.; Robinson, G.C.; Oland, C.B.

    1989-01-01

    A small crack near the inner surface of clad nuclear reactor pressure vessels is an important consideration in the safety assessment of the structural integrity of the vessel. Four-point bend tests on large plate specimens, conforming to ASTM specification for pressure vessel plates, alloy steels, quenched and tempered, Mn-Mo and Mn-Mo-Ni (A533) grade B six clad and two unclad with stainless steels 308, 309 and 312 weld wires, were performed to determine the effect of cladding upon the propagation of small surface cracks subjected to stress states. Results indicated that the tough surface layer composed of cladding and/or heat-affected zone has enhanced the load-bearing capacity of plates under conditions where unclad plates have ruptured. The results are interpreted in terms of fracture mechanics. The behavior of flaws in clad reactor pressure vessels is examined in the light of the test results. 11 refs., 8 figs., 2 tabs

  14. Performance test of the Multi-gap Resistive Plate Chamber (MRPC) with cosmic ray

    Science.gov (United States)

    Ikeda, Michihiko; Akieda, Tomomi; Tomita, Shoko; Ninomiya, Aki

    2014-09-01

    MRPC is a gaseous ionization detector, which a good timing resolution has been used practically in the nuclear and particle physics experiment. A mixed gas of SF6 and Fleon 134a was flowed through the gaps between high resistive plates (500 μm thickness glass). A high electric field of ~2 ×106 [V/m] was applied between the plates. A charged particle passes through the MRPC and causes avalanche amplification. We constructed a relatively small MRPC with a readout pad (20 mm × 50 mm). The development is motivated by feasibility study of the MRPC as a photon tagger at the Research Center for Electron Photon Science (ELPH), Tohoku University. The photon tagger needs a good timing resolution (<100 ps), therefore we studied the small size MRPC, while a large sized MRPCs are widely used in nuclear and particle experiments. The MRPC can operate under the strong magnetic field and thus it can be a good candidate as an electron detector placed in the magnet. We tested the HV dependence of time resolution of the MRPC with cosmic rays. The MRPC will be demonstrated at the open campus of the Tohoku University as an example of nuclear experimental detectors. We will measure the zenith angle and velocity distributions of cosmic ray.

  15. Plating on stainless steel alloys

    International Nuclear Information System (INIS)

    Dini, J.W.; Johnson, H.R.

    1981-01-01

    Quantitative adhesion data are presented for a variety of electroplated stainless steel type alloys. Results show that excellent adhesion can be obtained by using a Wood's nickel strike or a sulfamate nickel strike prior to final plating. Specimens plated after Wood's nickel striking failed in the deposit rather than at the interface between the substrate and the coating. Flyer plate quantitative tests showed that use of anodic treatment in sulfuric acid prior to Wood's nickel striking even further improved adhesion. In contrast activation of stainless steels by immersion or cathodic treatment in hydrochloric acid resulted in very reduced bond strengths with failure always occurring at the interface between the coating and substrate

  16. Apparent Polar Wander of the Pacific Plate Since the Cretaeous and Implications for True Polar Wander and for the Plate Motion Circuit Through Antarctica

    Science.gov (United States)

    Gordon, R. G.; Woodworth, D.

    2017-12-01

    In this presentation we review prior work on Pacific plate apparent polar wander and its implications (1) for true polar wander since ≈125 Ma and (2) for testing the global plate motion circuit through Antarctica. We furthermore update prior analyses using our recently improved and expanded apparent polar wander path for the Pacific plate [Woodworth et al., this meeting]. Three episodes of rapid motion of Pacific hotspots relative to the spin axis have occurred in the past ≈125 Ma: a ≈15° shift near 85 Ma [Gordon, 1983; Sager and Koppers, 2000], an ≈8° shift near the age of the Hawaiian-Emperor Bend [Petronotis et al., 1994; Woodworth et al., this meeting], and a 3°-°4 shift since 12 Ma [Woodworth et al., this meeting]. These shifts are in general agreement with the shifts of Indo-Atlantic hotspots relative to the spin axis. It has long been recognized that paleomagnetic poles from the continents, when rotated into the Pacific plate reference frame through plate motion circuits through Antarctica, are inconsistent with indigenous Pacific plate paleomagnetic poles and paleolatitudes [Suárez and Molnar, 1980; Gordon and Cox, 1980; Acton and Gordon, 1994]. We update such tests using our new and improved Pacific apparent polar wander path and show that the plate motion circuit through Antarctica still fails such paleomagnetic tests of consistency. Implications for global plate reconstructions and the hotspot reference frame will be discussed.

  17. Ex vivo biomechanical evaluation of pigeon (Columba livia) cadaver intact humeri and ostectomized humeri stabilized with caudally applied titanium locking plate or stainless steel nonlocking plate constructs.

    Science.gov (United States)

    Darrow, Brett G; Biskup, Jeffrey J; Weigel, Joseph P; Jones, Michael P; Xie, Xie; Liaw, Peter K; Tharpe, Josh L; Sharma, Aashish; Penumadu, Dayakar

    2017-05-01

    OBJECTIVE To evaluate mechanical properties of pigeon (Columba livia) cadaver intact humeri versus ostectomized humeri stabilized with a locking or nonlocking plate. SAMPLE 30 humeri from pigeon cadavers. PROCEDURES Specimens were allocated into 3 groups and tested in bending and torsion. Results for intact pigeon humeri were compared with results for ostectomized humeri repaired with a titanium 1.6-mm screw locking plate or a stainless steel 1.5-mm dynamic compression plate; the ostectomized humeri mimicked a fracture in a thin cortical bone. Locking plates were secured with locking screws (2 bicortical and 4 monocortical), and nonlocking plates were secured with bicortical nonlocking screws. Constructs were cyclically tested nondestructively in 4-point bending and then tested to failure in bending. A second set of constructs were cyclically tested non-destructively and then to failure in torsion. Stiffness, strength, and strain energy of each construct were compared. RESULTS Intact specimens were stiffer and stronger than the repair groups for all testing methods, except for nonlocking constructs, which were significantly stiffer than intact specimens under cyclic bending. Intact bones had significantly higher strain energies than locking plates in both bending and torsion. Locking and nonlocking plates were of equal strength and strain energy, but not stiffness, in bending and were of equal strength, stiffness, and strain energy in torsion. CONCLUSIONS AND CLINICAL RELEVANCE Results for this study suggested that increased torsional strength may be needed before bone plate repair can be considered as the sole fixation method for avian species.

  18. Interest of retro-anal levator plate myorrhaphy in selected cases of descending perineum syndrome with positive anti-sagging test

    Directory of Open Access Journals (Sweden)

    Beco Jacques

    2008-07-01

    Full Text Available Abstract Background Levator plate sagging (LPS, usually called descending perineum syndrome, is one of the main defects encountered in perineology. This defect is classically associated with colo-proctologic functional troubles (dyschesia and anal incontinence but can also induce perineodynia, gynaecological and lower urinary tract symptoms. Methods A retrospective case series of nine female patients (mean age: 44.3 underwent an isolated retro-anal levator plate myorrhaphy (RLPM to treat symptomatic LPS confirmed by rectal examination and/or Perineocaliper®. An anti-sagging test (support of the posterior perineum must significantly improve the symptoms that were resistant to conservative treatment. The effect of the procedure on the symptoms of the 3 axes of the perineum (urological, colo-proctologic and gynecological and on perineodynia was evaluated during a follow up consultation more than 9 months after surgery. The effect of RLPM on the position of the anal margin and on the levator plate angle was studied using rectal examination, Perineocaliper® and retro-anal ultrasound. Results Before surgery, anti-sagging tests were positive for dyschesia, urinary urgency and pain. After a mean follow-up of 16.1 months, RLPM resolved or improved 2/2 cases of stress urinary incontinence, 3/5 of urinary urgency, 3/4 of dysuria, 3/3 of anal incontinence, 7/8 of dyschesia, 3/4 of cystocele, 4/5 of rectocele, 5/8 of dyspareunia and 6/7 of perineodynia. Rectal examination showed a complete suppression of sagging in 4 patients and an improvement in the 5 others. The mean reduction of perineal descent was 1.08 cm (extremes: 0–1.5. Using retro-anal ultrasound of the levator plate, the mean reduction of sagging was 12.67 degrees (extremes: 1 – 21. Conclusion Anti-sagging tests can be used before surgery to simulate the effect of RLPM. This surgical procedure seems to improve stress urinary incontinence, frequency, nocturia, urgency, dysuria, anal

  19. An investigation of coated aluminium bipolar plates for PEMFC

    International Nuclear Information System (INIS)

    Lin, Chien-Hung; Tsai, Sung-Ying

    2012-01-01

    Highlights: ► Coated aluminium bipolar plates demonstrate the hydrophobic property than the raw material. ► The corrosion behaviour of bipolar plate decreases the PEMFC performance severely. ► These PEMFCs are measured by current–voltage (I–V) curve test. ► The oxide film increases the interfacial contact resistance. -- Abstract: The performance of Al-alloy bipolar plates for the PEMFC (proton exchange membrane fuel cell) system is investigated in this paper. The metallic bipolar plates are modified with a Ni–P coating. The performance of the Al-alloy bipolar plates is evaluated by the coating structure, corrosion resistance, contact angle and single cell performance. The results indicate that the coated aluminium bipolar plates demonstrate hydrophobic and anti-corrosive properties. The hydrophobic property increases the contact angle on the surface from 46.08° to 80.51°. Meanwhile, the corrosion rate of the Ni–P coating can be over 1 order of magnitude lower than that of the substrate. Hence, the substrate with the coating maintains superior performance under the long term test. The present study proves that both the hydrophobicity and corrosion resistance significantly affect the metallic bipolar plate.

  20. Evaluation of korzincalloy prepared by Hohman Plating

    Energy Technology Data Exchange (ETDEWEB)

    Korinko, P. S. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hollingshad, A. N. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-07-17

    A commercial vendor, Hohman Plating performed contract engineering work to determine the feasibility of producing pin hole free KorZincAlloy bronze material used for zinc gettering. Samples were tested for Sn plating thickness, heat treatability, and chemistry prior to being subjected to a standardized zinc exposure. The samples absorbed zinc and were examined using visual and scanning electron microscopy. Hohman Plating successfully produced KZA that met the target composition, was pin hole free, and was an effective zinc getter.

  1. Splitting in Dual-Phase 590 high strength steel plates

    International Nuclear Information System (INIS)

    Yang Min; Chao, Yuh J.; Li Xiaodong; Tan Jinzhu

    2008-01-01

    Charpy V-notch impact tests on 5.5 mm thick, hot-rolled Dual-Phase 590 (DP590) steel plate were evaluated at temperatures ranging from 90 deg. C to -120 deg. C. Similar tests on 2.0 mm thick DP590 HDGI steel plate were also conducted at room temperature. Splitting or secondary cracks was observed on the fractured surfaces. The mechanisms of the splitting were then investigated. Fracture surfaces were analyzed by optical microscope (OM) and scanning electron microscope (SEM). Composition of the steel plates was determined by electron probe microanalysis (EPMA). Micro Vickers hardness of the steel plates was also surveyed. Results show that splitting occurred on the main fractured surfaces of hot-rolled steel specimens at various testing temperatures. At temperatures above the ductile-brittle-transition-temperature (DBTT), -95 deg. C, where the fracture is predominantly ductile, the length and amount of splitting decreased with increasing temperature. At temperatures lower than the DBTT, where the fracture is predominantly brittle, both the length and width of the splitting are insignificant. Splitting in HDGI steel plates only appeared in specimens of T-L direction. The analysis revealed that splitting in hot-rolled plate is caused by silicate and carbide inclusions while splitting in HDGI plate results from strip microstructure due to its high content of manganese and low content of silicon. The micro Vickers hardness of either the inclusions or the strip microstructures is higher than that of the respective base steel

  2. Radiographic testing methods for welds of thin titanium plates and thin wall tubes

    International Nuclear Information System (INIS)

    1984-01-01

    This standard stipulates the testing method by X-ray radiography for the welded parts of titanium plates and titanium tubes with thickness not exceeding 8 mm. The other items than those stipulated here shall be in accordance with JIS Z 3107-1973 ''Testing method by radiography for the welded part of titanium and method of grade classification of radiographs''. As the photographing method of radiographs, the performance of the equipment and materials for testing, the direction of X-ray irradiation, the thickness of parent materials and welds, the use of penetrameters, the arrangement for photographing, the requirement for radiographs and the observation of radiographs are specified. The X-ray apparatuses, photo-sensitive materials and the tools for photographing and observation must be such that the radiographs clearly showing the defects in the welds being tested can be taken or observed. The JIS Z 3107 is insufficient for the test of thin materials like titanium, therefore, this standard was set down. As the thickness of welds, the thickness of parent materials was taken. In this standard, the titanium penetrameters were adopted because they can be made and they conform to practical state. If magnified photographing is carried out with microfocus X-ray apparatuses, precise photographing can be made. (Kako, I.)

  3. Size-Dependent Dynamic Behavior of a Microcantilever Plate

    Directory of Open Access Journals (Sweden)

    Xiaoming Wang

    2012-01-01

    Full Text Available Material length scale considerably affects the mechanical properties of microcantilever components. Recently, cantilever-plate-like structures have been commonly used, whereas the lack of studies on their size effects constrains the design, testing, and application of these structures. We have studied the size-dependent dynamic behavior of a cantilever plate based on a modified couple stress theory and the differential quadrature method in this note. The numerical solutions of microcantilever plate equation involving the size effect have been presented. We have also analyzed the bending and vibration of the microcantilever plates considering the size effect and discussed the dependence of the size effect on their geometric dimensions. The results have shown that (1 the mechanical characteristics of the cantilever plate show obvious size effects; as a result, the bending deflection of a microcantilever plate reduces whereas the natural frequency increases effectively and (2 for the plates with the same material, the size effect becomes more obvious when the plates are thinner.

  4. Critical assessment of precracked specimen configuration and experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate

    Science.gov (United States)

    Domack, M. S.

    1985-01-01

    A research program was conducted to critically assess the effects of precracked specimen configuration, stress intensity solutions, compliance relationships and other experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate. Modified compact and double beam wedge-loaded specimens were tested and analyzed to determine the threshold stress intensity factor and stress corrosion crack growth rate. Stress intensity solutions and experimentally determined compliance relationships were developed and compared with other solutions available in the literature. Crack growth data suggests that more effective crack length measurement techniques are necessary to better characterize stress corrosion crack growth. Final load determined by specimen reloading and by compliance did not correlate well, and was considered a major source of interlaboratory variability. Test duration must be determined systematically, accounting for crack length measurement resolution, time for crack arrest, and experimental interferences. This work was conducted as part of a round robin program sponsored by ASTM committees G1.06 and E24.04 to develop a standard test method for stress corrosion testing using precracked specimens.

  5. New technique for number-plate recognition

    Science.gov (United States)

    Guo, Jie; Shi, Peng-Fei

    2001-09-01

    This paper presents an alternative algorithm for number plate recognition. The algorithm consists of three modules. Respectively, they are number plate location module, character segmentation module and character recognition module. Number plate location module extracts the number plate from the detected car image by analyzing the color and the texture properties. Different from most license plate location methods, the algorithm has fewer limits to the car size, the car position in the image and the image background. Character segmentation module applies connected region algorithm both to eliminate noise points and to segment characters. Touching characters and broken characters can be processed correctly. Character recognition module recognizes characters with HHIC (Hierarchical Hybrid Integrated Classifier). The system has been tested with 100 images obtained from crossroad and parking lot, etc, where the cars have different size, position, background and illumination. Successful recognition rate is about 92%. The average processing time is 1.2 second.

  6. Heavy gauge plates for nuclear application

    International Nuclear Information System (INIS)

    Cheviet, A.; Roux, J.-H.

    1977-01-01

    The production of energy from nuclear sources leads to the building of very large vessels working under pressure at elevated temperatures, requiring very thick steel plate (from 50 mm to 300 mm). The plates necessary for the production of these vessels have to be as large as possible in order to reduce the length of welds on the vessels. Those two requirements lead to the manufacture of heavy products from 10 to 80 tons unit weight. These products are special, because their fabrication requires very big facilities and also extremely high quality of the steel. The main points are: high cleanliness; properties as homogeneous as possible. The tests carried out on industrially produced plates (especially on a plate of 200 mm thick show the level of quality that can be reached [fr

  7. Development of ultrasonic testing technique with the large transducer to inspect the containment vessel plates of nuclear power plant embedded in concrete

    International Nuclear Information System (INIS)

    Ishida, Hitoshi; Kurozumi, Yasuo; Kaneshima, Yoshiari

    2004-01-01

    The containment vessel plates embedded in concrete on Pressurized Water Reactors are inaccessible to inspect directly. Therefore, it is advisable to prepare inspection technology to detect existence and a location of corrosion on the embedded plates indirectly. In order to establish ultrasonic testing technique to be able to inspect the containment vessel plates embedded in concrete widely at the accessible point, experiments to detect artificial hollows simulating corrosion on a surface of a carbon steel plate mock-up covered with concrete simulating the embedded containment vessel plates were carried out with newly made ultrasonic transducers. We made newly low frequency (0.3 MHz and 0.5 MHz) surface shear horizontal (SH) wave transducers combined with three large active elements, which were equivalent to a 120mm width element. As a result of the experiments, the surface SH transducers could detect clearly the echo from the hollows with a depth of 9.5 mm and 19 mm at a distance of 1500mm from the transducers on the surface of the mock-up covered with concrete. Therefore, we evaluate that it is possible to detect the defects such as corrosion on the plates embedded in concrete with the newly made low frequency surface SH transducers with large elements. (author)

  8. High influx of carbon in walls of agglutinated foraminifers during the Permian-Triassic transition in global oceans

    Science.gov (United States)

    Nestell, Galina P.; Nestell, Merlynd K.; Ellwood, Brooks B.; Wardlaw, Bruce R.; Basu, Asish R.; Ghosh, Nilotpal; Phuong Lan, Luu Thi; Rowe, Harry D.; Hunt, Andrew G.; Tomkin, Jonathan H.; Ratcliffe, Kenneth T.

    2015-01-01

    The Permian–Triassic mass extinction is postulated to be related to the rapid volcanism that produced the Siberian flood basalt (Traps). Unrelated volcanic eruptions producing several episodes of ash falls synchronous with the Siberian Traps are found in South China and Australia. Such regional eruptions could have caused wildfires, burning of coal deposits, and the dispersion of coal fly ash. These eruptions introduced a major influx of carbon into the atmosphere and oceans that can be recognized in the wallstructure of foraminiferal tests present in survival populations in the boundary interval strata. Analysis of free specimens of foraminifers recovered from residues of conodont samples taken at aPermian–Triassic boundary section at Lung Cam in northern Vietnam has revealed the presence of a significant amount of elemental carbon, along with oxygen and silica, in their test wall structure, but an absence of calcium carbonate. These foraminifers, identified as Rectocornuspira kalhori, Cornuspira mahajeri, and Earlandia spp. and whose tests previously were considered to be calcareous, are confirmed to be agglutinated, and are now referred to as Ammodiscus kalhori and Hyperammina deformis. Measurement of the 207Pb/204Pb ratios in pyrite clusters attached to the foraminiferal tests confirmed that these tests inherited the Pb in their outer layer from carbon-contaminated seawater. We conclude that the source of the carbon could have been either global coal fly ash or forest fire-dispersed carbon, or a combination of both, that was dispersed into the Palaeo-Tethys Ocean immediately after the end-Permian extinction event.

  9. DESI focal plate mechanical integration and cooling

    Science.gov (United States)

    Lambert, A. R.; Besuner, R. W.; Claybaugh, T. M.; Silber, J. H.

    2016-08-01

    The Dark Energy Spectroscopic Instrument (DESI) is under construction to measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique[1]. The spectra of 40 million galaxies over 14000 sq. deg will be measured during the life of the experiment. A new prime focus corrector for the KPNO Mayall telescope will deliver light to 5000 fiber optic positioners. The fibers in turn feed ten broad-band spectrographs. This paper describes the mechanical integration of the DESI focal plate and the thermal system design. The DESI focal plate is comprised of ten identical petal assemblies. Each petal contains 500 robotic fiber positioners. Each petal is a complete, self-contained unit, independent from the others, with integrated power supply, controllers, fiber routing, and cooling services. The major advantages of this scheme are: (1) supports installation and removal of complete petal assemblies in-situ, without disturbing the others, (2) component production, assembly stations, and test procedures are repeated and parallelizable, (3) a complete, full-scale prototype can be built and tested at an early date, (4) each production petal can be surveyed and tested as a complete unit, prior to integration, from the fiber tip at the focal surface to the fiber slit at the spectrograph. The ten petal assemblies will be installed in a single integration ring, which is mounted to the DESI corrector. The aluminum integration ring attaches to the steel corrector barrel via a flexured steel adapter, isolating the focal plate from differential thermal expansions. The plate scale will be kept stable by conductive cooling of the petal assembly. The guider and wavefront sensors (one per petal) will be convectively cooled by forced flow of air. Heat will be removed from the system at ten liquid-cooled cold plates, one per petal, operating at ambient temperature. The entire focal plate structure is enclosed in an insulating shroud, which serves as a thermal barrier

  10. Biomechanical study: resistance comparison of posterior antiglide plate and lateral plate on synthetic bone models simulating Danis-Weber B malleolar fractures

    Directory of Open Access Journals (Sweden)

    Bruna Buscharino

    2013-06-01

    Full Text Available OBJECTIVE : The purpose of this study was to compare different positions of plates in lateral malleolar Danis-Weber B fractures on synthetic bone: a lateral plate and a posterior antiglide plate. METHODS : Short oblique fractures of distal fibula at the level of the syndesmosys were simulated with a fibular osteotomy in sixteen synthetic fibula bones (Synbone®. Eight fractures were fixed with lateral plating associated with an independent lag screw, and the other eight were fixed with posterior antiglide plating with a lag screw through the plate. A strain gage was installed at the center of each plate at the osteotomy site. Supination and external rotation forces were applied to each of the two groups at the bend. RESULTS : The lateral position plate group suffered more deformity in response to supination forces compared to the group with the posterior antiglide plate, but this result was not statistically significant. In the tests with external rotation forces, the posterior antiglide plating group had significantly higher resistance (p < 0.05. CONCLUSION : When subjected to external rotation forces, osteosynthesis with posterior antiglide plate models simulating type B fractures of the lateral malleolus of the ankle is more resistant than that of the neutralization plate.

  11. Quantitative computed tomography as a test of endurance for evaluation of bony plates

    International Nuclear Information System (INIS)

    Melo Filho, E.V.; Costa, L.A.V.S.; Oliveira, D.C.; Freitas, P.M.C.; Teixeira, M.W.; Costa, F.S.

    2012-01-01

    Quantitative computed tomography was used to determine the radiodensity of bony plates. The CT scans provided information regarding radiodensity of bony plates and allowed to verify the uniformity of bone mineral density in their scope. The proposed methodology should be considered as another tool for determining the resistance of these biomaterials. (author)

  12. Cold plate

    Energy Technology Data Exchange (ETDEWEB)

    Marroquin, Christopher M.; O' Connell, Kevin M.; Schultz, Mark D.; Tian, Shurong

    2018-02-13

    A cold plate, an electronic assembly including a cold plate, and a method for forming a cold plate are provided. The cold plate includes an interface plate and an opposing plate that form a plenum. The cold plate includes a plurality of active areas arranged for alignment over respective heat generating portions of an electronic assembly, and non-active areas between the active areas. A cooling fluid flows through the plenum. The plenum, at the non-active areas, has a reduced width and/or reduced height relative to the plenum at the active areas. The reduced width and/or height of the plenum, and exterior dimensions of cold plate, at the non-active areas allow the non-active areas to flex to accommodate surface variations of the electronics assembly. The reduced width and/or height non-active areas can be specifically shaped to fit between physical features of the electronics assembly.

  13. Testing micro-channel plate detectors for the particle identification upgrade of LHCb

    CERN Document Server

    Castillo Garcia, L

    2012-01-01

    The TORCH, Time of internally Reflected Cherenkov Light, is proposed for the high luminosity upgrade of the LHCb experiment. The detector combines Time-of-Flight and Cherenkov techniques to achieve positive pi/K/p separation on a >= 3 sigma level in the momentum range below 10 GeV/c. The required time resolution is <= 50 ps for single photon signal. In a preliminary R\\&D phase, we have shown that already commercially available micro-channel plate tubes with 8 x 8 channels fulfil the requirements. Timing properties of the tubes have been investigated with a pulsed laser diode in single photon regime. Key results from these laboratory tests are reported. An excellent timing resolution of <40 ps is achieved with an efficiency of similar to 90\\%. (C) 2011 Elsevier B.V. All rights reserved.

  14. A distal femoral supra-condylar plate: biomechanical comparison with condylar plate and first clinical application for treatment of supracondylar fracture.

    Science.gov (United States)

    Liang, Bowei; Ding, Zhenqi; Shen, Junguo; Zhai, Wenliang; Kang, Liangqi; Zhou, Liang; Sha, Mo; Liang, Dongzhu

    2012-08-01

    An anatomical supra-condylar plate is designed and analysed by biomechanical testing. The biomechanical properties of the supra-condylar and condylar plate were compared in six matched pairs of cadaveric femurs. A transverse osteotomy gap was created to simulate an OTA/AO type A3 supracondylar fracture. The left and right specimens were fitted with supra-condylar and condylar plate, respectively. Nondestructive axial compression, three-point bending and torsion tests were performed, and the peak load of the bone-implant construction was measured. The fracture site suitable for supra-condylar plate application and its correlation with femoral length were calculated. The gender influence on it was also discussed. The difference of stiffness between the supra-condylar and condyle groups were not significant (P > 0.05) at 363.4 and 362.5 N/mm for compression, 229.5 and 237.6 N/mm in the sagittal plane and 195.5 and 188.4 N/mm in the coronal plane for three-point bending, and 7.5 and 7.9 Nm/deg for axial torsion, respectively. The peak load was 4438 ± 136.15 N and 5215 ± 174.33 N, respectively, for the two groups. The average extent of the fracture site suitable for the application of the supra-condylar plate was 70.86 ± 4.61 mm. The femoral length and gender showed no influence on it. Despite the limited bone contact area provided by the supra-condylar plate, its construct stiffness is comparable to the condylar plate. The supra-condylar plate can be used to treat carefully-selected extra-articular supracondylar fractures.

  15. Anatomically contoured plates for fixation of rib fractures.

    Science.gov (United States)

    Bottlang, Michael; Helzel, Inga; Long, William B; Madey, Steven

    2010-03-01

    : Intraoperative contouring of long bridging plates for stabilization of flail chest injuries is difficult and time consuming. This study implemented for the first time biometric parameters to derive anatomically contoured rib plates. These plates were tested on a range of cadaveric ribs to quantify plate fit and to extract a best-fit plating configuration. : Three left and three right rib plates were designed, which accounted for anatomic parameters required when conforming a plate to the rib surface. The length lP over which each plate could trace the rib surface was evaluated on 109 cadaveric ribs. For each rib level 3-9, the plate design with the highest lP value was extracted to determine a best-fit plating configuration. Furthermore, the characteristic twist of rib surfaces was measured on 49 ribs to determine the surface congruency of anatomic plates with a constant twist. : The tracing length lP of the best-fit plating configuration ranged from 12.5 cm to 14.7 cm for ribs 3-9. The corresponding range for standard plates was 7.1-13.7 cm. The average twist of ribs over 8-cm, 12-cm, and 16-cm segments was 8.3 degrees, 20.6 degrees, and 32.7 degrees, respectively. The constant twist of anatomic rib plates was not significantly different from the average rib twist. : A small set of anatomic rib plates can minimize the need for intraoperative plate contouring for fixation of ribs 3-9. Anatomic rib plates can therefore reduce the time and complexity of flail chest stabilization and facilitate spanning of flail segments with long plates.

  16. Experimental tests of irradiation-anneal-reirradiation effects on mechanical properties of RPV plate and weld materials

    International Nuclear Information System (INIS)

    Hawthorne, J.R.

    1996-01-01

    The Charpy-V (C V ) notch ductility and tension test properties of three reactor pressure vessel (RPV) steel materials were determined for the 288 degree C (550 degree F) irradiated (I), 288 degree C (550 degree F) irradiated + 454 degree C (850 degree F)-168 h postirradiation annealed (IA), and 288 degree C (550 degree F) reirradiated (IAR) conditions. Total fluences of the I condition and the IAR condition were, respectively, 3.33 x 10 19 n/cm 2 and 4.18 x 10 19 n/cm 2 , E > 1 MeV. The irradiation portion of the IAR condition represents an incremental fluence increase of 1. 05 x 10 19 n/cm 2 , E > 1 MeV, over the I-condition fluence. The materials (specimens) were supplied by the Yankee Atomic Electric Company and represented high and low nickel content plates and a high nickel, high copper content weld deposit prototypical of the Yankee-Rowe reactor vessel. The promise of the IAR method for extending the fluence tolerance of radiation-sensitive steels and welds is clearly shown by the results. The annealing treatment produced full C V upper shelf recovery and full or nearly full recovery in the C V 41 J (30 ft-lb) transition temperature. The C V transition temperature increases produced by the reirradiation exposure were 22% to 43% of the increase produced by the first cycle irradiation exposure. A somewhat greater radiation embrittlement sensitivity and a somewhat greater reirradiation embrittlement sensitivity was exhibited by the low nickel content plate than the high nickel content plate. Its high phosphorus content is believed to be responsible. The IAR-condition properties of the surface vs. interior regions of the low nickel content plate are also compared

  17. Testing of a resistive plate chamber using NINO-ASIC based front end electronics

    International Nuclear Information System (INIS)

    Mondal, M.; Saini, J.; Ahammed, Z.; Chattopadhyay, S.; Ganai, R.; Barai, C.

    2017-01-01

    The Resistive Plate Chamber (RPC) has shown promising results while testing with the NINO FEE board. It has shown ∼ 80% efficiency in detecting cosmic muons with a noise rate of ∼ 40 Hz/cm 2 . The low threshold in the NINO board may be a possible reason for high noise rate. We plan to test the RPC for different gas mixtures to achieve an efficiency above 95%. The calibration of the NINO onboard threshold with input pulse amplitude need to be done. The time resolution of RPC is ∼ 2.66 ns at 12 kV for avalanche mode gas mixture. The minimum time resolution of the RPC has to determined by measuring the time spectra over the full plateau region of voltages. The signal charge has to be measured by time over- threshold for slewing correction. As J7 input of the board was not working properly, efficiency and noise rate data for the particular input has not been measured

  18. Dynamic tests and adaptive control of a bottoming organic Rankine cycle of IC engine using swash-plate expander

    International Nuclear Information System (INIS)

    Torregrosa, A.; Galindo, J.; Dolz, V.; Royo-Pascual, L.; Haller, R.; Melis, J.

    2016-01-01

    Highlights: • An experimental testing of a bottoming Rankine Cycle is presented and applied to a 2 l turbocharged gasoline engine. • Both stationary and transient tests were performed, including the NEDC cycle. • Indicated diagrams of the swash-plate expander during these transients were presented and analyzed. - Abstract: This paper deals with the experimental testing of a bottoming Organic Rankine Cycle (ORC) integrate in a 2 l turbocharged gasoline engine using ethanol as working fluid. The main components of the cycle are a boiler, a condenser, a pump and a swash-plate expander. Both steady and transient tests were performed in three engine operating points to understand the behavior and inertia of the system. Pressure-Volume diagram during these transients were presented and analyzed. Operating parameters of the expander, such as expander speed and boiler power, were shifted. The objective of these tests is to understand the inertia of the system and to have a robust control in all the possible transient tests. New European Driving Cycle was tested with and without the expander because it is supposed to represent the typical usage of a car in Europe. It was used to validate the control of the ORC in realistic dynamic conditions of the engine. The importance of each parameter was analyzed by fixing all the parameters, changing each time one specific value. The main result of this paper is that using a slightly simple and robust control based on adaptive PIDs, the two dynamic effects of an ORC could be taken into account, i.e. high inertia effects (boiler and condenser) and low inertia effects (pump and volumetric expander).

  19. Release of fission products from miniature fuel plates at elevated temperature

    International Nuclear Information System (INIS)

    Posey, J.C.

    1982-01-01

    Three miniature fuel plates were tested at progressively higher temperatures. A U 3 Si plated blistered and released fission gases at 500 0 C. Two U 3 O 8 filled plates blistered and released fission gases at 550 0 C

  20. Flow-induced plastic collapse of stacked fuel plates

    Energy Technology Data Exchange (ETDEWEB)

    Davis, D C; Scarton, H A

    1985-03-01

    Flow-induced plastic collapse of stacked fuel plate assemblies was first noted in experimental reactors such as the ORNL High Flux Reactor Assembly and the Engineering Test Reactor (ETR). The ETR assembly is a stack of 19 thin flat rectangular fuel plates separated by narrow channels through which a coolant flows to remove the heat generated by fission of the fuel within the plates. The uranium alloyed plates have been noted to buckle laterally and plastically collapse at the system design coolant flow rate of 10.7 m/s, thus restricting the coolant flow through adjacent channels. A methodology and criterion are developed for predicting the plastic collapse of ETR fuel plates. The criterion is compared to some experimental results and the Miller critical velocity theory.

  1. Failure of composite plates under static biaxial planar loading

    Science.gov (United States)

    Waas, Anthony M.; Khamseh, Amir R.

    1992-01-01

    The project involved detailed investigations into the failure mechanisms in composite plates as a function of hole size (holes centrally located in the plates) under static loading. There were two phases to the project, the first dealing with uniaxial loads along the fiber direction, and the second dealing with coplanar biaxial loading. Results for the uniaxial tests have been reported and published previously, thus this report will place emphasis on the second phase of the project, namely the biaxial tests. The composite plates used in the biaxial loading experiments, as well as the uniaxial, were composed of a single ply unidirectional graphite/epoxy prepreg sandwiched between two layers of transparent thermoplastic. This setup enabled us to examine the failure initiation and propagation modes nondestructively, during the test. Currently, similar tests and analysis of results are in progress for graphite/epoxy cruciform shaped flat laminates. The results obtained from these tests will be available at a later time.

  2. Determination of mechanical properties of carbon/epoxy plates by tensile stress test

    Science.gov (United States)

    Bere, Paul; Krolczyk, Jolanta B.

    2017-10-01

    The polymeric composite materials used in aerospace, military, medical or racing cars manufacturing end up being used in our daily life Whether we refer to the performing vehicles, subassemblies or parts for aircrafts, wind, telegraph poles, or medical prostheses they all are present in our lives and they are made of composite materials (CM). This paper presents research regarding three different composite materials, plates by carbon fiber, in epoxy matrix. Starting with materials presentation, manufacturing methodology and determination of mechanical properties at carbon fiber/epoxy were done. Vacuum bag technology to obtain the composite structure offer opportunity to get a very compact and homogeny composite structure. For the moment this technology are adequate for high performances pieces. The mechanical characteristics of plates made of composite materials reinforced presented indicates closed value like metal materials. Based on the results, a comparative study between the reinforced materials typically used to manufacture the plates of CM is carried out.

  3. Structure and properties of GMA surfaced armour plates

    OpenAIRE

    A. Klimpel; K. Luksa; M. Burda

    2010-01-01

    Purpose: In the combat vehicles many materials can be used for the armour. Application of the monolithic armour plates in light combat vehicles is limited by the high armour weigh. Introduction of the layered armour plates is a way to limit the vehicle weight. In the paper test results of graded and nanostructural GMA surfaced armour plates are presented.Design/methodology/approach: Metallographic structure, chemical composition and hardness of surfaced layers were investigated in order to ex...

  4. Comparison of the cystine-tryptic digest agar-carbohydrate co-agglutination and BACTEC Neisseria differentiation methods for identification of Neisseria gonorrhoeae in the clinical laboratory

    International Nuclear Information System (INIS)

    Morello, J.A.; Beheshti, S.; Bohnhoff, M.

    1980-01-01

    The author evaluated CTA-carbohydrate, BACTEC and co-agglutination systems to determine their accuracy for identifying N. gonorrhoeae strains and for distinguishing them from other Neisseria species. BACTEC is a radiometric assay based on the measurement of liberated radiolabelled CO 2 from metabolised carbohydrates which have been tagged with 14 C. (Auth.)

  5. [Comparison of novel infrared heating plates and conventional warm water plates for piglets' creep areas in farrowing pens].

    Science.gov (United States)

    Strauch-Sürken, L; Wendt, M

    2015-01-01

    On a conventionally managed piglet-producing farm, novel infrared (IR) heating plates for piglets in the farrowing pens were tested for their suitability and compared with common warm-water (WW) heating plates. In total, 134 litters (summer n = 82, winter n = 52) were investigated, which were housed on IR or WW heating plates, respectively, with or without an extra cover plate (groups 1-4). To determine the influence of the different heat sources, the wound healing after castration and tail docking, the umbilical regression and the weight gain of the piglets were investigated. Additionally, the lying behavior of the piglets and the position of the sows' udder at the time of farrowing were examined with regard to the heating plates. Furthermore, the energy consumption and costs were compared. The piglets housed on IR heating plates displayed better wound healing after castration and tail docking than the piglets housed on WW plates. The best results were obtained in piglets kept on IR heating plates with an extra cover plate. In addition, significant benefits were demonstrated for the usage of IR heating plates regarding umbilical regression. The piglets kept on IR heating plates had a slightly better weight gain in summer, whereas there were no differences between groups during winter. The lying behavior in the creep areas was similar in all groups. In general, with increasing age the percentage of time piglets spent in the lying position on the plates decreased. The percentage of time lying on the plates was higher in winter than in summer. At farrowing, 74.6% of all investigated sows directed their udder towards the heating plates. With the IR heating plates, this behavior occurred significantly more often. The energy consumption (kWh) per litter was significantly lower for the IR heating plates (electric power) both in winter and summer in comparison with the WW plates (gas). The energy costs were comparable in summer, but were higher for the IR heating plates

  6. Energy Analysis of Solar Collector With perforated Absorber Plate

    Directory of Open Access Journals (Sweden)

    Ammar A. Farhan

    2017-09-01

    Full Text Available The thermal performance of three solar collectors with 3, 6 mm and without perforation absorber plate was assessed experimentally. The experimental tests were implemented in Baghdad during the January and February 2017. Five values of airflow rates range between 0.01 – 0.1 m3/s were used through the test with a constant airflow rate during the test day. The variation of the following parameters air temperature difference, useful energy, absorber plate temperature, and collector efficiency was recorded every 15 minutes. The experimental data reports that the increases the number of absorber plate perforations with a small diameter is more efficient rather than increasing the hole diameter of the absorber plate with decreasing the perforation numbers. Maximum air temperature difference throughout the solar collector with 3, 6 mm perforations and without perforations are 17, 15, and 12 oC, respectively. Also, it can be concluded that the energy gained from the solar collector with 3 mm perforation absorber plate is 28.2 % more than the energy gained from solar collector without holes per day for 0.1 m3/s airflow rate. The maximum values of the thermal performance curves are 0.67, 0.64, and 0.56 for the solar collector with 3, 6 mm, and without perforations, respectively.

  7. Release of fission products from miniature fuel plates at elevated temperature

    International Nuclear Information System (INIS)

    Posey, John C.

    1983-01-01

    Three miniature fuel plates were tested at progressively higher temperatures. A U 3 Si filled plate blistered and released fission gases at 500 deg. C. Two U 3 O 8 filled plates blistered and released fission gases at 550 deg. C. (author)

  8. The study on corrosion resistance of decorative satin nickel plating

    Directory of Open Access Journals (Sweden)

    LU Wenya

    2012-10-01

    Full Text Available This study examined the corrosion resistance of satin nickel plating on conductive plastic.The electrochemical tests were to analyze the corrosion behavior of satin nickel plating with different processes in 3.5% NaCl solution.The results show that,because the satin nickel plating has an organic film on its surface due to process characteristics,the film results in different corrosion resistance.By increasing satin additive dosage,the nickel plating chroma decreases,the microsurface of the plating becomes rough,and the corrosion resistance is followed by decrease.

  9. Specifications, Pre-Experimental Predictions, and Test Plate Characterization Information for the Prometheus Critical Experiments

    International Nuclear Information System (INIS)

    ML Zerkle; ME Meyers; SM Tarves; JJ Powers

    2006-01-01

    This report provides specifications, pre-experimental predictions, and test plate characterization information for a series of molybdenum (Mo), niobium (Nb), rhenium (Re), tantalum (Ta), and baseline critical experiments that were developed by the Naval Reactors Prime Contractor Team (NRPCT) for the Prometheus space reactor development project. In March 2004, the Naval Reactors program was assigned the responsibility to develop, design, deliver, and operationally support civilian space nuclear reactors for NASA's Project Prometheus. The NRPCT was formed to perform this work and consisted of engineers and scientists from the Naval Reactors (NR) Program prime contractors: Bettis Atomic Power Laboratory, Knolls Atomic Power Laboratory (KAPL), and Bechtel Plant Machinery Inc (BPMI). The NRPCT developed a series of clean benchmark critical experiments to address fundamental uncertainties in the neutron cross section data for Mo, Nb, Re, and Ta in fast, intermediate, and mixed neutron energy spectra. These experiments were to be performed by Los Alamos National Laboratory (LANL) using the Planet vertical lift critical assembly machine and were designed with a simple, geometrically clean, cylindrical configuration consisting of alternating layers of test, moderator/reflector, and fuel materials. Based on reprioritization of missions and funding within NASA, Naval Reactors and NASA discontinued their collaboration on Project Prometheus in September 2005. One critical experiment and eighteen subcritical handstacking experiments were completed prior to the termination of work in September 2005. Information on the Prometheus critical experiments and the test plates produced for these experiments are expected to be of value to future space reactor development programs and to integral experiments designed to address the fundamental neutron cross section uncertainties for these refractory metals. This information is being provided as an orderly closeout of NRPCT work on Project

  10. Nickel-plating for active metal dissolution resistance in molten fluoride salts

    Energy Technology Data Exchange (ETDEWEB)

    Olson, Luke [Department of Engineering Physics, 1500 Engineering Drive, University of Wisconsin, Madison, WI 53706 (United States); Sridharan, Kumar, E-mail: kumar@engr.wisc.edu [Department of Engineering Physics, 1500 Engineering Drive, University of Wisconsin, Madison, WI 53706 (United States); Anderson, Mark; Allen, Todd [Department of Engineering Physics, 1500 Engineering Drive, University of Wisconsin, Madison, WI 53706 (United States)

    2011-04-15

    Ni electroplating of Incoloy-800H was investigated with the goal of mitigating Cr dissolution from this alloy into molten 46.5%LiF-11.5%NaF-42%KF eutectic salt, commonly referred to as FLiNaK. Tests were conducted in graphite crucibles at a molten salt temperature of 850 deg. C. The crucible material graphite accelerates the corrosion process due to the large activity difference between the graphite and the alloy. For the purposes of providing a baseline for this study, un-plated Incoloy-800H and a nearly pure Ni-alloy, Ni-201 were also tested. Results indicate that Ni-plating has the potential to significantly improve the corrosion resistance of Incoloy-800H in molten fluoride salts. Diffusion of Cr from the alloy through the Ni-plating does occur and if the Ni-plating is thin enough this Cr eventually dissolves into the molten salt. The post-corrosion test microstructure of the Ni-plating, particularly void formation was also observed to depend on the plating thickness. Diffusion anneals in a helium environment of Ni-plated Incoloy-800H and an Fe-Ni-Cr model alloy were also investigated to understand Cr diffusion through the Ni-plating. Further enhancements in the efficacy of the Ni-plating as a protective barrier against Cr dissolution from the alloy into molten fluoride salts can be achieved by thermally forming a Cr{sub 2}O{sub 3} barrier film on the surface of the alloy prior to Ni electroplating.

  11. [EIA-IgG antibody measles prevention level estimated from measles neutralizing, particle agglutination and hemagglutination-inhibition antibody titer].

    Science.gov (United States)

    Takayama, Naohide; Saika, Shizuko; Ichinohe, Sadato

    2009-09-01

    Measles hemagglutination inhibition (HI) antibody titer, widely used in clinical practice to simply and easily determine the measles immunity level has, in recent years, been increasingly replaced by measles IgG-antibody titer determined by enzyme-immunoassay (EIA). HI antibody titer appears to reflect this protective level, because HI measures the antibody against H protein required for the measles virus to adhere to host cells. EIA-IgG antibody titer does not correlate with the protective level, similar to particle agglutination (PA) titer, because EIA measures different antibodies, including those unrelated to measles protection. After determining HI, PA, neutralizing test (NT) results, and EIA-IgG antibody titer for individual specimens, we compared EIA-IgG antibody titer obtained using an EIA-Kit (Denka Seiken) to HI, PA, and NT titer with the following results: (1) Subjects with EIA-IgG titer of > or = 12.0 may be protected against measles: (2) Subjects with EIA-IgG titer of 4.0 to 8.0 appear to be protected insufficiently requiring a booster dose against measles: (3) Subjects with EIA-IgG titer of 8.0 to 12.0 may benefit from booster vaccination.

  12. Direct Detection of Methicillin Resistance in Staphylococcus aureus in Blood Culture Broth by Use of a Penicillin Binding Protein 2a Latex Agglutination Test▿

    OpenAIRE

    Qian, Qinfang; Venkataraman, Lata; Kirby, James E.; Gold, Howard S.; Yamazumi, Toshiaki

    2010-01-01

    We studied the utility of performing a penicillin binding protein 2a latex agglutination (PBP-LA) assay directly on Bactec blood culture broth samples containing Staphylococcus aureus to rapidly detect methicillin resistance. The sensitivity, specificity, positive predictive value, and negative predictive value of this method were 94.1%, 97.5%, 98%, and 92.9%, respectively.

  13. Scour Protection for Monopile by Concrete Plate

    DEFF Research Database (Denmark)

    Gilling, Lasse; Skúlason, Magnús

    A test programme has been performed to determine the scour around a monopile for an offshore wind turbine. The foundation is protected against scour with a concrete plate with various designs. The tests should be regarded as pilot tests previous to a detailed investigation. The tests has been...

  14. The study on corrosion resistance of decorative satin nickel plating

    OpenAIRE

    LU Wenya; CHENG Xianhua

    2012-01-01

    This study examined the corrosion resistance of satin nickel plating on conductive plastic.The electrochemical tests were to analyze the corrosion behavior of satin nickel plating with different processes in 3.5% NaCl solution.The results show that,because the satin nickel plating has an organic film on its surface due to process characteristics,the film results in different corrosion resistance.By increasing satin additive dosage,the nickel plating chroma decreases,the microsurface of the p...

  15. Prevalence of agglutinating antibodies to Toxoplasma gondii in striped skunks (Mephitis mephitis), opossums (Didelphis virginiana), and raccoons (Procyon lotor) from Connecticut

    OpenAIRE

    Mitchell, S. M.; Richardson, D. J.; Lindsay, D. S.

    2006-01-01

    The prevalence of agglutinating antibodies to Toxoplasma gondii was examined in striped skunks (Mephitis mephitis), opossums (Didelphis virginiana), and raccoons (Procyon lotor) from 8 cities in Connecticut. Ten (42%) of the 24 striped skunks, 2 of 7 (29%) opossums, and 12 of 12 (100%) raccoons were positive at dilutions of 1:50 or greater. These results suggest that T. gondii is prevalent in the environment, or prey items, or both, of these omnivores in Connecticut.

  16. Prevalence of agglutinating antibodies to Toxoplasma gondii in striped skunks (Mephitis mephitis), opossums (Didelphis virginiana), and raccoons (Procyon lotor) from Connecticut.

    Science.gov (United States)

    Mitchell, Sheila M; Richardson, Dennis J; Lindsay, David S

    2006-06-01

    The prevalence of agglutinating antibodies to Toxoplasma gondii was examined in striped skunks (Mephitis mephitis), opossums (Didelphis virginiana), and raccoons (Procyon lotor) from 8 cities in Connecticut. Ten (42%) of the 24 striped skunks, 2 of 7 (29%) opossums, and 12 of 12 (100%) raccoons were positive at dilutions of 1:50 or greater. These results suggest that T. gondii is prevalent in the environment, or prey items, or both, of these omnivores in Connecticut.

  17. Field trial of a brucellosis competitive enzyme linked immunoabsorbent assay (ELISA)

    International Nuclear Information System (INIS)

    Samartino, L.E.; Gregoret, R.J.; Sigal, G.

    1998-01-01

    The purpose of this study was to evaluate the performance of a competitive ELISA system for the diagnosis of bovine brucellosis in comparison to conventional aerological tests routinely used in Argentina. A total of 2.500 serum samples, comprising Brucella-free herds, vaccinated cattle and naturally infected animals, was tested by the following tests: buffered plate agglutination, Rose Bengal, 2-mercaptoethanol, complement fixation, and indirect and competitive ELISAs. Specificity and relative sensitivity at each test were determined. The competitive ELISA was considered suitable for detection of vaccinated animals and had higher specificity than the other tests. The results point to the potential use of the test as a complementary assay in the brucellosis control programme in Argentina. (author)

  18. A novel microtiter plate radioimmunoassay of insulin autoantibody

    International Nuclear Information System (INIS)

    Huang Gan; Li Zhangwei; Jin Helai; Wang Xia; Wang Jianping; Zhou Zhiguang

    2009-01-01

    Objective: Insulin autoantibody (IAA) is known to exist in sera of type 1 diabetes mellitus (T1DM) patients and pre-T1DM individuals. The aim of this study was to establish a novel mierotiter plate radioimmunoassay (RIA) for IAA and evaluate its clinical value. Methods: Diluted 125 I-insulin was mixed with 5 μl serum samples in a 96-well microtiter plate and then incubated for 72 h on an orbital plate shaker (4 degree C). The immunocomplexes were transferred to another protein a coated Millipore plate, and then the plate was washed with Tri-Buffered Saline Tween-20 (TBT) buffer. Counts per minute (CPM) was measured with liquid scintillation and luminescence counter. The positive cut-off point of IAA index was defined as ≥0.06 based on the 99-percentile of the distribution in 317 healthy individuals. The specificity and sensitivity of the assay were calculated from the samples provided by the fourth Diabetes Autoantibodies Standardization Program (DASP 2005). The IAA levels were determined in 71 T1DM and 551 newly diagnosed type 2 diabetes (T2DM) patients, and 317 healthy controls. The t test, non-parametric test, χ 2 test and linear correlation analysis were performed on the data using SPSS 11.5 software. The concordance rate was estimated with Kappa value. Results: (1) The optimized testing condition was described as 2 x 10 4 CPM of 125 I-insulin, 5 μl serum sample and slowly horizontal shaking for 72 h. (2) The intra-assay CV was 4.8%-8.9% and inter-assay CV was 6.4%-10.5%. Based on DASP 2005 samples, the specificity and sensitivity of the assay were 97% (97/100) and 50% (25/50), respectively. Ninety-six serum samples with different IAA levels were selected and tested to compare between our new method and a domestic IAA RIA kit. The results showed that the IAA indices from the two methods were positively correlated (r= 0.678, P<0.001). The concordance rate was 72.9% (Kappa value=0.402). There were 25 samples with discordant results, which were positive for

  19. A STUDY ON PROXIMAL HUMERAL FRACTURES STABILISED WITH PHILOS PLATE

    Directory of Open Access Journals (Sweden)

    Praveen Sivakumar K

    2017-02-01

    Full Text Available BACKGROUND Techniques for treating complex proximal humeral fractures vary and include fixations using tension bands, percutaneous pins, bone suture, T-plates, intramedullary nails, double tubular plates, hemiarthroplasty, plant tan humerus fixator plates, Polaris nails and blade plates. Complications of these techniques include cutout or back out of the screws and plates, avascular necrosis, nonunion, malunion, nail migration, rotator cuff impairment and impingement syndromes. Insufficient anchorage from conventional implants may lead to early loosening and failure, especially in osteoporotic bones. In general, nonoperative treatment of displaced three and four-part fractures of the proximal humerus leads to poor outcome due to intraarticular nature of injury and inherent instability of the fragments. Comminuted fractures of the proximal humerus are at risk of fixation failure, screw loosening and fracture displacement. Open reduction and internal fixation with conventional plate and screws has been associated with unacceptably high incidence of screw pull out. PHILOS (the proximal humeral internal locking system plate is an internal fixation system that enables angled stabilisation with multiple interlocking screws for fractures of the proximal humerus. MATERIALS AND METHODS 30 patients with proximal humerus fractures who were admitted in the Department of Orthopaedics, Government General Hospital, Kakinada, during the period November 2014 - November 2016 were taken up for study according to inclusion criteria. All patients were treated with PHILOS plate. These proximal humerus fractures were classified according to Neer’s classification. Patients were followed up at 6 weeks, 12 weeks and 6 months’ interval. Functional outcomes for pain, range of motion and muscle power and function were assessed using the Constant-Murley scoring system. Collected data analysed with independent t-test and ANNOVA test. RESULTS The outcome of the study was 1

  20. Radiation shielding plate

    International Nuclear Information System (INIS)

    Kobayashi, Torakichi; Sugawara, Takeo.

    1983-01-01

    Purpose: To reduce the weight and stabilize the configuration of a radiation shielding plate which is used in close contact with an object to be irradiated with radiation rays. Constitution: The radiation shielding plate comprises a substrate made of lead glass and a metallic lead coating on the surface of the substrate by means of plating, vapor deposition or the like. Apertures for permeating radiation rays are formed to the radiation shielding plate. Since the shielding plate is based on a lead glass plate, a sufficient mechanical strength can be obtained with a thinner structure as compared with the conventional plate made of metallic lead. Accordingly, if the shielding plate is disposed on a soft object to be irradiated with radiation rays, the object and the plate itself less deform to obtain a radiation irradiation pattern with distinct edges. (Moriyama, K.)

  1. Plating on difficult-to-plate metals: what's new

    International Nuclear Information System (INIS)

    Wiesner, H.J.

    1980-01-01

    Some of the changes since 1970 in procedures for plating on such materials as titanium, molybdenum, silicon, aluminum, and gallium arsenide are summarized. While basic procedures for plating some of these materials were developed as many as 30 to 40 years ago, changes in the end uses of the plated products have necessitated new plating processes. In some cases, vacuum techniques - such as ion bombardment, ion implantation, and vacuum metallization - have been introduced to improve the adhesion of electrodeposits. In other cases, these techniques have been used to deposit materials upon which electrodeposits are required

  2. Plating laboratory

    International Nuclear Information System (INIS)

    Seamster, A.G.; Weitkamp, W.G.

    1984-01-01

    The lead plating of the prototype resonator has been conducted entirely in the plating laboratory at SUNY Stony Brook. Because of the considerable cost and inconvenience in transporting personnel and materials to and from Stony Brook, it is clearly impractical to plate all the resonators there. Furthermore, the high-beta resonator cannot be accommodated at Stony Brook without modifying the set up there. Consequently the authors are constructing a plating lab in-house

  3. The Round robin test of the PISC-2 programme: plates and ultrasonic procedures used PISC 2 report N.2. Final issue

    International Nuclear Information System (INIS)

    1986-09-01

    Ultrasonic testing is widely used for detecting, locating and sizing defects in primary circuit elements at various stages of plant life. The successive PISC projects have together made up a most notable sustained international effort to assess the effectiveness of these inspection techniques. The Plate Inspection Steering Committee (PISC-I) programme (1976-1980) was intended to establish the capabilities of manual ultrasonic procedure based on the 1974 ASME Code Section XI Procedure. The Programme for the Inspection of Steel Components (PISC-II, 1981-1986) constitutes a broader based evaluation of the best performance obtainable by modern ultrasonic techniques under optimal conditions. The present paper is the second in a series of reports currently being issued which describe the results of the PISC-II studies. Included are descriptions of the four round robin test plates and of the ultrasonic procedures applied to them by the participating inspection teams. The report also lists the participating organisations and gives the time schedule of the tests and an indication of the costs incurred

  4. Post irradiation examinations on UMo full-sized plates - IRIS2 experiment

    International Nuclear Information System (INIS)

    Huet, F.; Noirot, J.; Marelle, V.; Dubois, S.; Boulcourt, P.; Sacristan, P.; Naury, S.; Lemoine, P.

    2005-01-01

    IRIS2 irradiation was the last irradiation of 4 full sized plates launched by CEA for the French UMo group to test in which operating conditions the coarse porosity forms in the UMo/Al interaction product. IRIS2 consists in four plates with high uranium loading and U-7wt%Mo atomised powder irradiated up to 60 days at OSIRIS reactor in IRIS device at a peak power of 238 W.cm -2 . The results show that in the tested conditions pillowing of the plate started from a fission density over 2.10 21 fission.cm -3 . Moreover, they show that the fission products and impurities have a key-role in the origin of the excessive plate swelling. (author)

  5. Tokamak fusion test reactor FELIX plate experiment

    International Nuclear Information System (INIS)

    Hua, T.O.; Nygren, R.E.; Turner, L.R.

    1986-01-01

    For a conducting material exposed to both a time-varying and a static magnetic field, such as a limiter blade in a tokamak, the induced eddy currents and the deflection arising from those eddy currents can be strongly coupled. The coupling effects reduce the currents and deflections markedly, sometimes an order of magnitude, from the values predicted if coupling is neglected. A series of experiments to study current-deflection coupling were performed using the Fusion Electromagnetic Inductance Experiment (FELIX) facility at Argonne National Laboratory. Magnetic damping and magnetic stiffness resulting from the coupling are discussed, and analytical expressions for induced eddy current and rigid body rotation in the FELIX plate experiment are compared with the experimental results. Predictions for the degree of coupling based on various parameters are made using the analytical model

  6. Mycoplasma gallopavonis in eastern wild turkeys.

    Science.gov (United States)

    Luttrell, M P; Eleazer, T H; Kleven, S H

    1992-04-01

    Serum samples and tracheal cultures were collected from eastern wild turkeys (Meleagris gallopavo sylvestris) trapped for relocation in South Carolina (USA) during 1985 to 1990. Sera were tested for Mycoplasma gallisepticum and M. synoviae by the rapid plate agglutination and hemagglutination inhibition tests and were found to be negative. Tracheal cultures were negative for all pathogenic Mycoplasma spp., including M. gallisepticum, M. synoviae, M. meleagridis, and M. iowae. However, M. gallopavonis was isolated from every group of wild turkeys tested in 1986 to 1990. These data suggest that M. gallopavonis, which is generally considered nonpathogenic, may be a common microorganism in eastern wild turkeys.

  7. Hybrid method for consistent model of the Pacific absolute plate motion and a test for inter-hotspot motion since 70Ma

    Science.gov (United States)

    Harada, Y.; Wessel, P.; Sterling, A.; Kroenke, L.

    2002-12-01

    Inter-hotspot motion within the Pacific plate is one of the most controversial issues in recent geophysical studies. However, it is a fact that many geophysical and geological data including ages and positions of seamount chains in the Pacific plate can largely be explained by a simple model of absolute motion derived from assumptions of rigid plates and fixed hotspots. Therefore we take the stand that if a model of plate motion can explain the ages and positions of Pacific hotspot tracks, inter-hotspot motion would not be justified. On the other hand, if any discrepancies between the model and observations are found, the inter-hotspot motion may then be estimated from these discrepancies. To make an accurate model of the absolute motion of the Pacific plate, we combined two different approaches: the polygonal finite rotation method (PFRM) by Harada and Hamano (2000) and the hot-spotting technique developed by Wessel and Kroenke (1997). The PFRM can determine accurate positions of finite rotation poles for the Pacific plate if the present positions of hotspots are known. On the other hand, the hot-spotting technique can predict present positions of hotspots if the absolute plate motion is given. Therefore we can undertake iterative calculations using the two methods. This hybrid method enables us to determine accurate finite rotation poles for the Pacific plate solely from geometry of Hawaii, Louisville and Easter(Crough)-Line hotspot tracks from around 70 Ma to present. Information of ages can be independently assigned to the model after the poles and rotation angles are determined. We did not detect any inter-hotspot motion from the geometry of these Pacific hotspot tracks using this method. The Ar-Ar ages of Pacific seamounts including new age data of ODP Leg 197 are used to test the newly determined model of the Pacific plate motion. The ages of Hawaii, Louisville, Easter(Crough)-Line, and Cobb hotspot tracks are quite consistent with each other from 70 Ma to

  8. Parallel susceptibility testing of bacteria through culture-quantitative PCR in 96-well plates

    Directory of Open Access Journals (Sweden)

    Jun Luo

    2018-05-01

    Full Text Available Objective: The methods combining culture and quantitative PCR(qPCR offer new solutions for rapid antibiotic susceptibility testing(AST. However, the multiple steps of DNA extraction and cold storage of PCR reagents needed make them unsuitable for rapid high throughput AST. In this study, a parallel culture-qPCR method was developed to overcome above problems. Method: In this method, bacteria culture and DNA extraction automatically and simultaneously completed through using a common PCR instrument as a controllable heating device. A lyophilized 16S rDNA targeted qPCR reagent was also developed, which was stable and could be kept at 4 °C for long time and at 37 °C for about two months. Result: Testing of 36 P. aeruginosa isolates and 28 S. aureus isolates showed that the method had good agreements with the standard broth microdilution method, with an overall agreement of 97.22% (95% CI, 85.83–99.51 for P. aeruginosa and 96.43% (95% CI, 79.76–99.81 for S. aureus. This method could test 12 samples against a panel of up to 7 antibiotics simultaneously in two 96-well PCR plates within 4 h, which greatly improves the testing efficiency of the culture-qPCR method. Conclusion: With rapidness to obtain results and the capabilities for automation and multiple-sample testing, the parallel culture-qPCR method would have great potentials in clinical labs. Keywords: Antibiotic susceptibility testing, Thermo-cold lysis, Lyophilized qPCR reagent, Quantitative PCR, Bacteria

  9. Brucellosis in Patients with Crimean-Congo Hemorrhagic Fever

    Directory of Open Access Journals (Sweden)

    Fazilet Duygu

    2017-12-01

    Full Text Available Background: Crimean-Congo hemorrhagic fever (CCHF is a fatal zoonotic viral disease caused by infection with a tick-borne virus of the genus Nairovirus. In this study, we investigated the incidence of brucellosis in patients diag­nosed with CCHF.Methods: Overall, 169 patients hospitalized with an initial diagnosis of CCHF were included in 2011 in To­kat/ Turkey. Immunoglobulin M (IgM antibodies and/or PCR results were used in the laboratory diagnosis of CCHF, while plate and standard tube agglutination (STA tests were used to diagnose brucellosis.Results: Overall, 120 patients (79% with positive PCR tests were diagnosed with CCHF. Five (4.16% were also diag­nosed with brucellosis based on the positive plate and STA test results. Four patients (2.36% had negative CCHF PCR and positive STA test results.Conclusion: Brucellosis and CCHF can mimic each other and that all patients with CCHF or brucellosis should be screened for both conditions.

  10. Irradiation testing of stainless steel plate material and weldments. Report on ITER Task T14, Part B. Tensile properties after 0.5 and 5 dpa at 350 and 500 K

    International Nuclear Information System (INIS)

    Rensman, J.W.; Boskeljon, J.; Horsten, M.G.; De Vries, M.I.

    1997-10-01

    The tensile properties of unirradiated and neutron irradiated type 316L(N)-SPH stainless steel plate, EB weldments, 16-8 TIG-weldments, and full 16-8 TIG-deposits have been measured. Miniature 4 mm diameter test specimens of the European Reference Heat 1 and 2 (ERH), and 4 mm and some 8 mm diameter specimens of the weldments mentioned above, were irradiated in the High Flux Reactor (HFR) in Petten, The Netherlands, simulating the first wall conditions by a combination of high displacement damage with high amounts of helium. The irradiation conditions were 0.5 and 5 displacements per atom (dpa) at 350K and 0.5 and 5 dpa at 500K. Testing temperatures ranged from 300K to 850K. This work was performed as part of the European Fusion Technology Programme for ITER as 'Irradiation testing of stainless steel' The report contains the experimental conditions and summarises the results. The tensile properties of the unirradiated ERH's 1 and 2 plate materials were found to differ slightly but significantly: ERH2 has a lower UTS, but higher yield strength and ductility than ERH1. The plate materials have lower yield strength in the unirradiated condition than all of the weldments (EB, TIG-weld and TIG-deposit), accompanied by a higher ductility of the plate materials. When irradiated at 350K the differences in strength between the plate and weld materials decrease, but the ductility of the plate remains higher than that of the weldments. A saturation of irradiation damage has taken place already at about 0.5 dpa. When irradiated at 500K the plate material continuously hardens up to 5 dpa, where it has lost all uniform plastic ductility. The weldments show similar but less dramatic hardening and loss of ductility as the plate material for both irradiation conditions. 54 figs., 17 tabs., 21 refs

  11. Electron beam test of an iron/gas calorimeter based on ceramic parallel plate chambers

    International Nuclear Information System (INIS)

    Arefiev, A.; Bencze, Gy.L.; Bizzeti, A.; Choumilov, E.; Civinini, C; Dalla Santa, F.; D'Alessandro, R.; Ferrando, A.; Fouz, M.C.; Herve, A.; Iglesias, A.; Ivochkin, V.; Josa, M.I.; Maggi, F.; Malinin, A.; Meschini, M.; Pojidaev, V.; Radermacher, E.; Salicio, J.M.

    1995-01-01

    The baseline option for the very forward calorimetry in the CMS experiment is an iron/gas calorimeter based on parallel plate chambers. A small prototype module of such a calorimeter, has been tested using electrons of 5 to 100 GeV/c momentum with various high voltages and two gases: CO2 (100%) and CF4/CO2 (80/20), at atmospheric pressure. The collected charge has been measured as a function of the high voltage and of the electron energy. The energy resolution has also been measured. Comparisons have been made with Monte-Carlo predictions. Agreement between data an simulation allows to make and estimation of the expected performance of a full size calorimeter. (Author) 23 refs

  12. Electron beam test of an iron/gas calorimeter based on ceramic parallel plate chambers

    International Nuclear Information System (INIS)

    Arefiev, A.; Bencze, G.L.; Bizzeti, A.; choumilov, E.; Civinini, C.; Dalla Santa, F.; D'Alessandro, R.; Ferrando, A.; Fouz, M.C.; Herve, A.; Iglesias, A.; Ivochkin, V.; Josa, M.I.; Maggi, F.; Malininin, A.; Meschini, M.; Pojidaev, V.; Radermacher, E.; Salicio, J.M.

    1995-12-01

    The baseline option for the very forward calorimetry in the CMS experiment is an iron/gas calorimeter based on parallel plate chambers. A small prototype module of such a calorimeter, has been tested using electrons of 5 to 100 GeV/c momentum with various high voltages and two gases: CO 2 (100%) and CF 4 /CO 2 (80/20), at atmospheric pressure. The collected charge has been measured as a function of the high voltage and of the electron energy. The energy resolution has also been measured. Comparisons have been made with Monte-Carlo predictions. Agreement between data an simulation allows to make and estimation of the expected performance of a full size calorimeter. (Author)

  13. Create Your Plate

    Medline Plus

    Full Text Available ... Plate Share Create Your Plate ! Share: Seven Simple Steps to Create Your Plate It's simple and effective ... foods within each food category. Try these seven steps to get started: Using your dinner plate, put ...

  14. Plate Versus Intramedullary Nail Fixation of Anterior Tibial Stress Fractures: A Biomechanical Study.

    Science.gov (United States)

    Markolf, Keith L; Cheung, Edward; Joshi, Nirav B; Boguszewski, Daniel V; Petrigliano, Frank A; McAllister, David R

    2016-06-01

    Anterior midtibial stress fractures are an important clinical problem for patients engaged in high-intensity military activities or athletic training activities. When nonoperative treatment has failed, intramedullary (IM) nail and plate fixation are 2 surgical options used to arrest the progression of a fatigue fracture and allow bone healing. A plate will be more effective than an IM nail in preventing the opening of a simulated anterior midtibial stress fracture from tibial bending. Controlled laboratory study. Fresh-frozen human tibias were loaded by applying a pure bending moment in the sagittal plane. Thin transverse saw cuts, 50% and 75% of the depth of the anterior tibial cortex, were created at the midtibia to simulate a fatigue fracture. An extensometer spanning the defect was used to measure the fracture opening displacement (FOD) before and after the application of IM nail and plate fixation constructs. IM nails were tested without locking screws, with a proximal screw only, and with proximal and distal screws. Plates were tested with unlocked bicortical screws (standard compression plate) and locked bicortical screws; both plate constructs were tested with the plate edge placed 1 mm from the anterior tibial crest (anterior location) and 5 mm posterior to the crest. For the 75% saw cut depth, the mean FOD values for all IM nail constructs were 13% to 17% less than those for the saw cut alone; the use of locking screws had no significant effect on the FOD. The mean FOD values for all plate constructs were significantly less than those for all IM nail constructs. The mean FOD values for all plates were 28% to 46% less than those for the saw cut alone. Anterior plate placement significantly decreased mean FOD values for both compression and locked plate constructs, but the mean percentage reductions for locked and unlocked plates were not significantly different from each other for either plate placement. The percentage FOD reductions for all plate

  15. Momordica charantia seed lectin: toxicity, bacterial agglutination and antitumor properties.

    Science.gov (United States)

    Kabir, Syed Rashel; Nabi, Md Mahamodun; Nurujjaman, Md; Abu Reza, Md; Alam, A H M Khurshid; Uz Zaman, Rokon; Khalid-Bin-Ferdaus, Khandaker Md; Amin, Ruhul; Khan, Md Masudul Hasan; Hossain, Md Anowar; Uddin, Md Salim; Mahmud, Zahid Hayat

    2015-03-01

    In last three decades, several studies were carried out on the D-galactose-specific lectin of Momordica charantia seeds (MCL). In the present study, in vitro growth inhibition (8-23 %) at different concentrations (6-24 μg/ml) of MCL was observed against Ehrlich ascites carcinoma (EAC) cells by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay. MCL also showed 28, 45, and 75 % growth inhibitions against EAC cells when administered 1.2, 2.0, and 2.8 mg/kg/day (i.p.), respectively for five consequent days in vivo in mice. After lectin treatment, the level of red blood cell and hemoglobin was increased significantly with the decrease of white blood cell and maintained the normal level when compared with EAC-bearing control and normal mice without EAC cells. Although MCL caused cell cycle arrest at G0/G1 phase of EAC cells, any irregular shape or apoptotic morphological alterations in the lectin-treated EAC cells was not observed by an optical and fluorescence microscope. Lectin showed toxicity against brine shrimp nauplii with an LC50 value of 49.7 μg/ml. Four out of seven pathogenic bacteria were agglutinated by MCL in the absence of inhibitory sugar D-lactose/D-galactose. In conclusion, MCL showed strong cytotoxic effect and therefore can be used as a potent anticancer chemotherapeutic agent.

  16. The use of the rapid osmotic fragility test as an additional test to diagnose canine immune-mediated haemolytic anaemia

    DEFF Research Database (Denmark)

    Paes, Geert; Paepe, Dominique; Meyer, Evelyne

    2013-01-01

    Background: Diagnosing canine immune-mediated haemolytic anaemia (IMHA) is often challenging because all currently available tests have their limitations. Dogs with IMHA often have an increased erythrocyte osmotic fragility (OF), a characteristic that is sometimes used in the diagnosis of IMHA...... hyperlipemic dogs (group 3), 10 dogs with lymphoma (group 4), 8 dogs with an infection (group 5) and 13 healthy dogs (group 6) were included. In all dogs, blood smear examination, in-saline auto-agglutination test, Coombs' test, COFT and ROFT were performed. In the COFT, OF5, OF50 and OF90 were defined...

  17. Creep-fatigue evaluation method for weld joint of Mod.9Cr-1Mo steel Part II: Plate bending test and proposal of a simplified evaluation method

    Energy Technology Data Exchange (ETDEWEB)

    Ando, Masanori, E-mail: ando.masanori@jaea.go.jp; Takaya, Shigeru, E-mail: takaya.shigeru@jaea.go.jp

    2016-12-15

    Highlights: • Creep-fatigue evaluation method for weld joint of Mod.9Cr-1Mo steel is proposed. • A simplified evaluation method is also proposed for the codification. • Both proposed evaluation method was validated by the plate bending test. • For codification, the local stress and strain behavior was analyzed. - Abstract: In the present study, to develop an evaluation procedure and design rules for Mod.9Cr-1Mo steel weld joints, a method for evaluating the creep-fatigue life of Mod.9Cr-1Mo steel weld joints was proposed based on finite element analysis (FEA) and a series of cyclic plate bending tests of longitudinal and horizontal seamed plates. The strain concentration and redistribution behaviors were evaluated and the failure cycles were estimated using FEA by considering the test conditions and metallurgical discontinuities in the weld joints. Inelastic FEA models consisting of the base metal, heat-affected zone and weld metal were employed to estimate the elastic follow-up behavior caused by the metallurgical discontinuities. The elastic follow-up factors determined by comparing the elastic and inelastic FEA results were determined to be less than 1.5. Based on the estimated elastic follow-up factors obtained via inelastic FEA, a simplified technique using elastic FEA was proposed for evaluating the creep-fatigue life in Mod.9Cr-1Mo steel weld joints. The creep-fatigue life obtained using the plate bending test was compared to those estimated from the results of inelastic FEA and by a simplified evaluation method.

  18. Creep-fatigue evaluation method for weld joint of Mod.9Cr-1Mo steel Part II: Plate bending test and proposal of a simplified evaluation method

    International Nuclear Information System (INIS)

    Ando, Masanori; Takaya, Shigeru

    2016-01-01

    Highlights: • Creep-fatigue evaluation method for weld joint of Mod.9Cr-1Mo steel is proposed. • A simplified evaluation method is also proposed for the codification. • Both proposed evaluation method was validated by the plate bending test. • For codification, the local stress and strain behavior was analyzed. - Abstract: In the present study, to develop an evaluation procedure and design rules for Mod.9Cr-1Mo steel weld joints, a method for evaluating the creep-fatigue life of Mod.9Cr-1Mo steel weld joints was proposed based on finite element analysis (FEA) and a series of cyclic plate bending tests of longitudinal and horizontal seamed plates. The strain concentration and redistribution behaviors were evaluated and the failure cycles were estimated using FEA by considering the test conditions and metallurgical discontinuities in the weld joints. Inelastic FEA models consisting of the base metal, heat-affected zone and weld metal were employed to estimate the elastic follow-up behavior caused by the metallurgical discontinuities. The elastic follow-up factors determined by comparing the elastic and inelastic FEA results were determined to be less than 1.5. Based on the estimated elastic follow-up factors obtained via inelastic FEA, a simplified technique using elastic FEA was proposed for evaluating the creep-fatigue life in Mod.9Cr-1Mo steel weld joints. The creep-fatigue life obtained using the plate bending test was compared to those estimated from the results of inelastic FEA and by a simplified evaluation method.

  19. Diagnostic Tests in Human Brucellosis

    Directory of Open Access Journals (Sweden)

    Hamid Reza Nouri

    2014-07-01

    Full Text Available Context: Brucellosis represents a zoonotic bacterial disease, caused by a gram negative bacterium called Brucella. Between the diverses pecies of this bacteria, B. melitensis, B. abortus, B. suis and B. canis consist the main causes of the disease in humans.More than half a million new cases of Brucellosis are reported annually. Consequently, brucellosis is a remarkable threat for the health of society. Because of the multiple nonspecific clinical signs of this infection, such as fever (60% of cases, night sweating, insomnia and anorexia, which are similar to other diseases, the detection of brucellosis is time-consuming and needs more scrutiny. Evidence Acquisition: Blood culture is considered the gold standard for the detection of brucellosis and the sensitivity of this test in the acute form is high. However, for the chronic type of disease, it is remarkably low, in addition, in some cases, it needs long reaction times. Nevertheless, today, some kinds of tests like automatic culturing system and serological methods, such as Rose Bengal (RB test, serum agglutination test (SAT, 2-mercaptoethanol (2ME and coombs, which are operated based on agglutination, are useful for the problems mentioned earlier. Conclusion: Although serological methods are common for the diagnosis of brucellosis, false results are observable for several methods, such as the SAT method. Tests like the enzyme-linked immunosorbent assay (ELISA, for the screening of specific traits, although confirmed, have their advantages and defects. The lateral flow assay (LFA shows promising evidence to be effective in the diagnosis of brucellosis. The polymerase chain reaction (PCR is more prevalent than other common tests, according to sensitivity and fast answering potency in case of molecular diagnosis. Also, PCR is proper for patients' follow-up during the period of treatment and crimination of relapse by this method is easier compared to others.

  20. Non-linear finite element analyses of wide plate fracture mechanics experiments

    International Nuclear Information System (INIS)

    Harrop, L.P.; Gibson, S.

    1988-06-01

    A series of centre-cracked, wide plate fracture mechanics tests is being conducted with plates made from 0.36% carbon steel. This report gives an account of post-test finite element analyses performed to compare with the results of one of these tests (designated CSTP4) and a pre-test analysis of the next test which has a slightly different geometry (CSTP5). The plates are relatively thick (75mm) and have a width of 1.62m. The finite element analyses use a two-dimensional plane stress mesh. The work shows good agreement between the post-test analysis results and the overall experimental results for CSTP4. It is not expected that the analysis results will be accurate within the dimensions of the process zone ahead of the crack tip; the mesh is not sufficient for this. A vital ingredient in attaining the good overall agreement is the representation of the actual stress-strain curve of the material. The predicted response of test CSTP5 is markedly different from that of CSTP4 even though the only change is the increase in the height of the plate. In particular the shape and size of the plastic zone ahead of the crack tip is quite different in the two tests at the same nominal remote applied load. (author)

  1. On the lamb wave propagation in anisotropic laminated composite plates

    International Nuclear Information System (INIS)

    Park, Soo Keun; Jeong, Hyun Jo; Kim, Moon Saeng

    1998-01-01

    This paper examines the propagation of Lamb (or plate) waves in anisotropic laminated composite plates. The dispersion relations are explicitly derived using the classical plate theory (CLT), the first-order shear deformation theory (FSDT) and the exact solution (ES), Attention is paid to the lowest antisymmetric (flexural) and lowest symmetric(extensional) modes in the low frequency, long wavelength limit. Different values of shear correction factor were tested in FSDT and comparisons between flexural wave dispersion curves were made with exact results to asses the range of validity of approximate plate theories in the frequency domain.

  2. Selenium plating of aluminium and nickel surfaces

    International Nuclear Information System (INIS)

    Qureshi, N.; Shams, N.; Kamal, A.; Ashraf, A.

    1993-01-01

    Selenium exhibits photovoltaic and photoconductive properties. This makes selenium useful in the production of photocells, exposure meters for photographic use, in solar cells, etc. In commerce, selenium coated surfaces are extensively used as photo receptive drums in the xerography machines for reproducing documents. Laboratory experiments were designed to obtain selenium plating on different materials. Of the various electrodes tested for cathodic deposition, anodized aluminum and nickel plated copper were found to give good results. (author)

  3. Hot-rolled Process of Multilayered Composite Metal Plate

    Directory of Open Access Journals (Sweden)

    YU Wei

    2017-02-01

    Full Text Available For multi-layer plate, it is a difficult problem to increase product yield rate and improve bonding interface quality. A high yield hot-rolled method of multilayered plate was proposed. The raw strips and plate were fixed by argon arc welding. The combined billet was put into a metal box and vacuum pumped, and then heated and rolled by multi passes at the temperature of 1000-1200℃. The 67 layered plate with the thickness of 2.5mm was successfully produced. The interfacial microstructures and diffusion behavior were investigated and analyzed by optical microscopy and scan electronic microscopy. The tensile and shear strength were tested,and the shear fractures were analyzed. The results show that the multilayered plate yield rate is more than 90% by two steps billet combination method and rolling process optimization. The good bonding interface quality is obtained, the shear strength of multilayered plate reaches 241 MPa. Nickel interlayer between 9Cr18 and 1Cr17 can not only prevent the diffusion of carbon, but also improve the microstructure characteristics.

  4. Low cost bare-plate solar air collector

    Science.gov (United States)

    Maag, W. L.; Wenzler, C. J.; Rom, F. E.; Vanarsdale, D. R.

    1980-09-01

    A low cost, bare plate solar collector for preheating ambient air was developed. This type of solar heating system would be applicable for preheating ventilation air for public buildings or other commercial and industrial ventilation requirements. Two prototype collectors were designed, fabricated and installed into an instrumented test system. Tests were conducted for a period of five months. Results of the tests showed consistent operating efficiencies of 60 percent or greater with air preheat temperature uses up to 20 degrees for one of the prototypes. The economic analyses indicated that this type of solar system was economically viable. For the materials of construction and the type of fabrication and installation perceived, costs for the bare plate solar collector are attainable. Applications for preheating ventilation air for schools were evaluated and judged to be economically viable.

  5. The study of fix composite panel and steel plates on testing stand

    Science.gov (United States)

    Wróbel, A.; Płaczek, M.; Wachna, M.

    2016-08-01

    In this paper the practical possibilities of strength verification analysis of composite materials used in the manufacture of selected components of railway wagons are presented. Real laboratory stand for measurements in a scale controlled by PLC controller were made. The study of different types of connections of composite materials with sheet metal is presented. In one of the chapter of this paper principles construction of testing stand with pneumatic cylinder were presented. Mainly checking of displacements and stresses generated on the sheet as a result of pneumatic actuators load for composite boards was carried out. The use of the controller with operating panel allows to easy programming testing cycle. The user can define the force generated by the actuator by change of air pressure in cylinder. Additionally the location of acting cylinders and their jump can be changed by operator. The examination of the volume displacements was done by displacement sensor, and the tensile strain gauge. All parameters are written in CatmanEasy - data acquisition software. This article presents the study of stresses and displacements in the composite plates joined with sheet metal, in summary of this article, the authors compare the obtained results with the computer simulation results in the article: "Simulation of stresses in an innovative combination of composite with sheet".

  6. Biomechanical testing of a hybrid locking plate fixation of equine sesamoid osteotomies.

    Science.gov (United States)

    Almeida da Silveira, E; Levasseur, A; Lacourt, M; Elce, Y; Petit, Y

    2014-01-01

    To compare the biomechanical properties of a hybrid locking compression plate (LCP) construct with the compression screw technique as a treatment for transverse mid-body proximal sesamoid bone fractures. Ten paired forelimbs from abattoir horses were used. The medial proximal sesamoid bone of each limb was osteotomized transversely and randomly assigned, to either repair with a two-hole 3.5 mm LCP or a 4.5 mm cortical screw placed in lag fashion. Each limb was tested biomechanically by axial loading in single cycle until failure. The point of failure was evaluated from the load-displacement curves. Then a gross evaluation and radiographs were performed to identify the mode of failure. The loads to failure of limbs repaired with the hybrid LCP construct (4968 N ± 2167) and the limbs repaired with the screw technique (3009 N ± 1091) were significantly different (p fracture of the apical fragment of the proximal sesamoid bone. The LCP technique has potential to achieve a better fracture stability and healing when applied to mid-body fractures of the proximal sesamoid bone. Further testing, particularly fatigue resistance is required to corroborate its potential as a treatment option for mid-body fractures of the proximal sesamoid bone.

  7. Low velocity impact of 6082-T6 aluminum plates

    Science.gov (United States)

    Mocian, Oana Alexandra; Constantinescu, Dan Mihai; Sandu, Marin; Sorohan, Ştefan

    2018-02-01

    The low velocity domain covers vehicle impacts, ship collisions and even accidentally tool drops. Even though more and more research is needed into these fields, most of the papers concerning impact problems focus on impact at medium and high velocities. Understanding the behavior of structures subjected to low velocity impact is of major importance when referring to impact resistance and damage tolerance. The paper presents an experimental and numerical investigation on the low velocity behavior of 6082-T6 aluminum plates. Impact tests were performed using an Instron Ceast 9340 drop-weight testing machine. In the experimental procedure, square plates were mounted on a circular support, fixed with a pneumatic clamping system and impacted with a hemispherical steel projectile. Specimens were impacted at constant weight and different impact velocities. The effect of different impact energies was investigated. The impact event was then simulated using the nonlinear finite element code LS_DYNA in order to determine the effect of strain rate upon the mechanical behavior of the aluminum plates. Moreover, in order to capture the exact behavior of the material, a special attention has been given to the selection of the correct material model and its parameters, which, in large extent, depend on the observed behavior of the aluminum plate during the test and the actual response of the plate under simulation. The numerical predictions are compared with the experimental observations and the applicability of the numerical model for further researches is analyzed.

  8. and Indigenous Indirect Enzyme-Linked Immunosorbent Assay

    Directory of Open Access Journals (Sweden)

    Annapurna S. Agasthya

    2012-01-01

    Full Text Available Brucellosis is one of the most important reemerging zoonoses in many countries. Brucellosis is caused by Gram-negative coccobacillus belonging to genus Brucella. Human brucellosis often makes the diagnosis difficult. The symptoms and clinical signs most commonly reported are fever, fatigue, malaise, chills, sweats headaches, myalgia, arthralgia, and weight loss. Some cases have been presented with only joint pain, lower backache, and involuntary limb movement, burning feet, or ischemic heart attacks. The focus of this work was to develop a highly sensitive and specific indirect ELISA by using smooth lipopolysaccharide antigen of Brucella abortus 99 to detect anti-Brucella antibodies at Project Directorate on Animal Disease Monitoring and Surveillance. Serum samples collected from 652 individuals in whom fever was not the major symptom but the complaint was of joint pain, headache, lower backache, and so forth, were screened by Rose Bengal plate agglutination test (RBPT and standard tube agglutination test (STAT. Subsequent testing of sera by indigenous indirect ELISA detected 20 samples positive (3.6% seroprevalence, and indirect ELISA was found to be more sensitive than RBPT and STAT. The seroprevalence in South Karnataka was 2.14%, and in North Karnataka it was 0.92%.

  9. Scale-up of Carbon/Carbon Bipolar Plates

    Energy Technology Data Exchange (ETDEWEB)

    David P. Haack

    2009-04-08

    This project was focused upon developing a unique material technology for use in PEM fuel cell bipolar plates. The carbon/carbon composite material developed in this program is uniquely suited for use in fuel cell systems, as it is lightweight, highly conductive and corrosion resistant. The project further focused upon developing the manufacturing methodology to cost-effectively produce this material for use in commercial fuel cell systems. United Technology Fuel Cells Corp., a leading fuel cell developer was a subcontractor to the project was interested in the performance and low-cost potential of the material. The accomplishments of the program included the development and testing of a low-cost, fully molded, net-shape carbon-carbon bipolar plate. The process to cost-effectively manufacture these carbon-carbon bipolar plates was focused on extensively in this program. Key areas for cost-reduction that received attention in this program was net-shape molding of the detailed flow structures according to end-user design. Correlations between feature detail and process parameters were formed so that mold tooling could be accurately designed to meet a variety of flow field dimensions. A cost model was developed that predicted the cost of manufacture for the product in near-term volumes and long-term volumes (10+ million units per year). Because the roduct uses lowcost raw materials in quantities that are less than competitive tech, it was found that the cost of the product in high volume can be less than with other plate echnologies, and can meet the DOE goal of $4/kW for transportation applications. The excellent performance of the all-carbon plate in net shape was verified in fuel cell testing. Performance equivalent to much higher cost, fully machined graphite plates was found.

  10. On the material properties of shell plate formed by line heating

    Directory of Open Access Journals (Sweden)

    Hyung Kyun Lim

    2017-01-01

    Full Text Available This paper is concerned with investigating the plastic material properties of steel plate formed by line heating method, and is aimed at implementing more rational design considering the accidental limit states such as collision or grounding. For the present study, line heating test for marine grade steel plate has been carried out with varying plate thickness and heating speed, and then microscopic examination and tensile test have been carried out. From the microscopic, it is found that the grain refined zones like ferrite and pearlite are formed all around the heat affected zone. From the tensile test results, it is seen that yield strength, tensile strength, fracture strain, hardening exponent and strength coefficient vary with plate thickness and heat input quantity. The formulae relating the material properties and heat input parameter should be, therefore, derived for the design purpose considering the accidental impact loading. This paper ends with describing the extension of the present study.

  11. A locking compression plate versus the gold-standard non-locking plate with lag screw for first metatarsophalangeal fusion: A biomechanical comparison.

    Science.gov (United States)

    Mandell, Daniel; Karbassi, John; Zhou, Hanbing; Burroughs, Brian; Aurigemma, Philip; Patel, Abhay R

    2018-03-01

    The treatment of end-stage first metatarso-phalangeal joint (MTP) arthritis has been arthrodesis. A dorsal non-locking plate with a lag screw has been the standard traditional fixation method. This study compares the biomechanical strength of a locking compression plate (LCP) with and without internal compression versus this known gold standard. In group 1, six matched pairs of cadaver great toes were used to compare the standard non-locking dorsal plate and 3.5mm lag screw to an anatomic locking compression plate in which a lag screw was utilized rather than the internal compression features of the plate. In group 2, another six matched pairs of cadaver great toes were used to compare the gold standard to the locking compression plate, utilizing the plate's internal compression feature instead of a lag screw. A material testing system (MTS) machine applied loads to the MTP joints and measured displacement and stiffness of the constructs. The stiffness of the constructs (Young's modulus) was calculated from the force-displacement curves, and the displacement was measured. The locking compression plate group that used the compression features of the plate, without the lag screw, had less joint displacement and higher stiffness than control (p<0.05). The same plating construct in which a lag screw was used rather than internal compression of the plate was found to be stiffer than the control (p<0.05), but displacement was not statistically significant. The results suggest that a locking compression plate alone provides the stiffest construct for a first MTP joint fusion. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Laser-induced selective copper plating of polypropylene surface

    Science.gov (United States)

    Ratautas, K.; Gedvilas, M.; Stankevičiene, I.; JagminienÄ--, A.; Norkus, E.; Li Pira, N.; Sinopoli, S.; Emanuele, U.; Račiukaitis, G.

    2016-03-01

    Laser writing for selective plating of electro-conductive lines for electronics has several significant advantages, compared to conventional printed circuit board technology. Firstly, this method is faster and cheaper at the prototyping stage. Secondly, material consumption is reduced, because it works selectively. However, the biggest merit of this method is potentiality to produce moulded interconnect device, enabling to create electronics on complex 3D surfaces, thus saving space, materials and cost of production. There are two basic techniques of laser writing for selective plating on plastics: the laser-induced selective activation (LISA) and laser direct structuring (LDS). In the LISA method, pure plastics without any dopant (filler) can be used. In the LDS method, special fillers are mixed in the polymer matrix. These fillers are activated during laser writing process, and, in the next processing step, the laser modified area can be selectively plated with metals. In this work, both methods of the laser writing for the selective plating of polymers were investigated and compared. For LDS approach, new material: polypropylene with carbon-based additives was tested using picosecond and nanosecond laser pulses. Different laser processing parameters (laser pulse energy, scanning speed, the number of scans, pulse durations, wavelength and overlapping of scanned lines) were applied in order to find out the optimal regime of activation. Areal selectivity tests showed a high plating resolution. The narrowest width of a copper-plated line was less than 23 μm. Finally, our material was applied to the prototype of the electronic circuit board on a 2D surface.

  13. Paper microzone plates.

    Science.gov (United States)

    Carrilho, Emanuel; Phillips, Scott T; Vella, Sarah J; Martinez, Andres W; Whitesides, George M

    2009-08-01

    This paper describes 96- and 384-microzone plates fabricated in paper as alternatives to conventional multiwell plates fabricated in molded polymers. Paper-based plates are functionally related to plastic well plates, but they offer new capabilities. For example, paper-microzone plates are thin (approximately 180 microm), require small volumes of sample (5 microL per zone), and can be manufactured from inexpensive materials ($0.05 per plate). The paper-based plates are fabricated by patterning sheets of paper, using photolithography, into hydrophilic zones surrounded by hydrophobic polymeric barriers. This photolithography used an inexpensive formulation photoresist that allows rapid (approximately 15 min) prototyping of paper-based plates. These plates are compatible with conventional microplate readers for quantitative absorbance and fluorescence measurements. The limit of detection per zone loaded for fluorescence was 125 fmol for fluorescein isothiocyanate-labeled bovine serum albumin, and this level corresponds to 0.02 the quantity of analyte per well used to achieve comparable signal-to-noise in a 96-well plastic plate (using a solution of 25 nM labeled protein). The limits of detection for absorbance on paper was approximately 50 pmol per zone for both Coomassie Brilliant Blue and Amaranth dyes; these values were 0.4 that required for the plastic plate. Demonstration of quantitative colorimetric correlations using a scanner or camera to image the zones and to measure the intensity of color, makes it possible to conduct assays without a microplate reader.

  14. Divergent plate motion drives rapid exhumation of (ultra)high pressure rocks

    Science.gov (United States)

    Liao, Jie; Malusà, Marco G.; Zhao, Liang; Baldwin, Suzanne L.; Fitzgerald, Paul G.; Gerya, Taras

    2018-06-01

    Exhumation of (ultra)high pressure [(U)HP] rocks by upper-plate divergent motion above an unbroken slab, first proposed in the Western Alps, has never been tested by numerical methods. We present 2D thermo-mechanical models incorporating subduction of a thinned continental margin beneath either a continental or oceanic upper plate, followed by upper-plate divergent motion away from the lower plate. Results demonstrate how divergent plate motion may trigger rapid exhumation of large volumes of (U)HP rocks directly to the Earth's surface, without the need for significant overburden removal by erosion. Model exhumation paths are fully consistent with natural examples for a wide range of upper-plate divergence rates. Exhumation rates are systematically higher than the divergent rate imposed to the upper plate, and the modeled size of exhumed (U)HP domes is invariant for different rates of upper-plate divergence. Major variations are instead predicted at depth for differing model scenarios, as larger amounts of divergent motion may allow mantle-wedge exhumation to shallow depth under the exhuming domes. The transient temperature increase, due to ascent of mantle-wedge material in the subduction channel, has a limited effect on exhumed continental (U)HP rocks already at the surface. We test two examples, the Cenozoic (U)HP terranes of the Western Alps (continental upper plate) and eastern Papua New Guinea (oceanic upper plate). The good fit between model predictions and the geologic record in these terranes encourages the application of these models globally to pre-Cenozoic (U)HP terranes where the geologic record of exhumation is only partly preserved.

  15. A new discrete Kirchhoff-Mindlin element based on Mindlin-Reissner plate theory and assumed shear strain fields. I - An extended DKT element for thick-plate bending analysis. II - An extended DKQ element for thick-plate bending analysis

    Science.gov (United States)

    Katili, Irwan

    1993-06-01

    A new three-node nine-degree-of-freedom triangular plate bending element is proposed which is valid for the analysis of both thick and thin plates. The element, called the discrete Kirchhoff-Mindlin triangle (DKMT), has a proper rank, passes the patch test for thin and thick plates in an arbitrary mesh, and is free of shear locking. As an extension of the DKMT element, a four-node element with 3 degrees of freedom per node is developed. The element, referred to as DKMQ (discrete Kirchhoff-Mindlin quadrilateral) is found to provide good results for both thin and thick plates without any compatibility problems.

  16. Investigation of heave response of the deepwater octagonal FDPSO using various heave plate configurations

    Science.gov (United States)

    Yu, Chenfang; Hu, Zhiqiang; Wang, Shisheng

    2017-12-01

    Heave plates can be employed to control undesirable heave motion amplitudes of the deepwater octagonal Floating, Drilling, Production, Storage, and Offloading (FDPSO) platform. Numerical simulations and model tests were applied to analyze and investigate the hydrodynamic response and the feasibility of the heave plate configurations. The diameter and the depth below the free surface of a single-layer heave plate, as well as the spacing of two-layer heave plates, were considered as the primary variables when studying the effect of heave plates on FDPSO hydrodynamics. The analysis results indicate that the heave plate diameter significantly affects the heave hydrodynamics, and heave performance could be improved with an increased diameter. In addition, increasing the depth below the free surface of a single-layer heave plate does not effectively suppress the heave motion within the range of draft depths tested. The target FDPSO obtained better heave characteristics with increased spacing between the two-layer heave plates. Furthermore, the global performances of the octagonal FDPSO with these typical heave plate configurations were comparatively analyzed. The results indicate that from a hydrodynamic point of view, the single-layer heave plate configuration has an advantage over the two-layer heave plate configuration.

  17. Low velocity impact on polymer composite plates in contact with water

    Directory of Open Access Journals (Sweden)

    Y Kwon

    2016-09-01

    Full Text Available In this study, composite materials were tested in two different environments to determine the role of Fluid Structure Interaction with composites under a low velocity impact. This was done using a low velocity impact machine and polymer composite plates. The composite is made of laminated symmetrical plain weave E-glass fabrics. The test area of the composite plates is 30.5 cm by 30.5 cm with clamped boundary conditions. The testing was done using a drop weight system to impact the center of the test area. One testing was performed with composite plates in air, called dry impact. The other testing was conducted while composite plates were submerged in water, called wet impact. A Plexiglas box in conjunction with the impact machine was used to keep the top of the composite sample dry while it was submerged in an anechoic water tank, so called water-backed air impact. Output from the tests was recorded using strain gauges and a force impact sensor. The results show that an added mass effect from the water plays a large role in the Fluid Structure Interaction with composites due to the similar densities of water and the composites. The wet impact results in a larger impact force and damage than the dry impact under the same impact condition, i.e., the same impact mass and drop height.

  18. Fuel plate stability experiments and analysis for the Advanced Neutron Source

    International Nuclear Information System (INIS)

    Swinson, W.F.; Battiste, R.L.; Luttrell, C.R.; Yahr, G.T.

    1992-01-01

    The planned Advanced Neutron Source (ANS) and several existing reactors use closely spaced arrays of involute shaped fuel-plates which are cooled by water flowing through the channels between the plates. There is concern that at certain coolant flow velocities adjacent plates may deflect and touch, with resulting failure of the plates. Experiments have been conducted at the Oak Ridge National Laboratory to examine this potential phenomenon. Results of the experiments and comparison with analytical predictions are reported in this paper. The tests were conducted using full scale epoxy plate models of the aluminum/uranium silicide ANS involute shaped fuel plates. Use of epoxy plates and model theory allowed lower flow velocities and pressures to explore the potential failure mechanism. Plate deflections and channel pressures as function of the flow velocity are examined. Comparisons with mathematical models are noted. 12 refs

  19. Fuel plate stability experiments and analysis for the Advanced Neutron Source

    International Nuclear Information System (INIS)

    Swinson, W.F.; Battiste, R.L.; Luttrell, C.R.; Yahr, G.T.

    1993-05-01

    The planned reactor for the Advanced Neutron Source (ANS) will use closely spaced arrays of involute-shaped fuel plates that will be cooled by water flowing through the channels between the plates. There is concern that at certain coolant flow velocities, adjacent plates may deflect and touch, with resulting failure of the plates. Experiments have been conducted at the Oak Ridge National Laboratory to examine this potential phenomenon. Results of the experiments and comparison with analytical predictions are reported. The tests were conducted using full-scale epoxy plate models of the aluminum/uranium silicide ANS involute-shaped fuel plates. Use of epoxy plates and model theory allowed lower flow velocities and pressures to explore the potential failure mechanism. Plate deflections and channel pressures as functions of the flow velocity are examined. Comparisons with mathematical models are noted

  20. Crack-arrest behavior in SEN wide plates of low-upper-shelf base metal tested under nonisothermal conditions: WP-2 series

    International Nuclear Information System (INIS)

    Naus, D.J.; Keeney-Walker, J.; Bass, B.R.; Robinson, G.C. Jr.; Iskander, S.K.; Alexander, D.J.; Fields, R.J.; deWit, R.; Low, S.R.; Schwartz, C.W.

    1990-08-01

    The Heavy-Section Steel Technology (HSST) Program at the Oak Ridge National Laboratory under the sponsorship of the Nuclear Regulatory Commission is conducting analytical and experimental studies aimed at understanding the circumstances that would initiate the growth of an existing crack in a reactor pressure vessel (RPV) and the conditions leading to arrest of a propagating crack. Objectives of these studies are to determine (1) if the material will exhibit crack-arrest behavior when the driving force on a crack exceeds the ASME limit, (2) the relationship between K Ia and temperature, and (3) the interaction of fracture modes (arrest, stable crack growth, unstable crack growth, and tensile instability) when arrest occurs at high temperatures. In meeting these objectives, crack-arrest data are being developed over an expanded temperature range through tests involving large thermally shocked cylinders, pressurized thermally shocked vessels, and wide-plate specimens. The wide-plate specimens provide the opportunity for a significant number of data points to be obtained at relatively affordable costs. These tests are designed to provide fracture-toughness measurements approaching or above the onset of the Charpy upper-shelf regime in a rising toughness region and with an increasing driving force. This document discusses test methodology and results. 23 refs., 92 figs., 25 tabs

  1. Directional bending wave propagation in periodically perforated plates

    DEFF Research Database (Denmark)

    Andreassen, Erik; Manktelow, Kevin; Ruzzene, Massimo

    2015-01-01

    We report on the investigation of wave propagation in a periodically perforated plate. A unit cell with double-C perforations is selected as a test article suitable to investigate two-dimensional dispersion characteristics, group velocities, and internal resonances. A numerical model, formulated...... using Mindlin plate elements, is developed to predict relevant wave characteristics such as dispersion, and group velocity variation as a function of frequency and direction of propagation. Experimental tests are conducted through a scanning laser vibrometer, which provides full wave field information...... for the design of phononic waveguides with directional and internal resonant characteristics....

  2. Development of plate-fin heat exchanger for intermediate heat exchanger of high-temperature gas cooled reactor. Fabrication process, high-temperature strength and creep-fatigue life prediction of plate-fin structure made of Hastelloy X

    International Nuclear Information System (INIS)

    Mizokami, Yorikata; Igari, Toshihide; Nakashima, Keiichi; Kawashima, Fumiko; Sakakibara, Noriyuki; Kishikawa, Ryouji; Tanihira, Masanori

    2010-01-01

    The helium/helium heat exchanger (i.e., intermediate heat exchanger: IHX) of a high-temperature gas-cooled reactor (HTGR) system with nuclear heat applications is installed between a primary system and a secondary system. IHX is operated at the highest temperature of 950degC and has a high capacity of up to 600 MWt. A plate-fin-type heat exchanger is the most suitable for IHX to improve construction cost. The purpose of this study is to develop an ultrafine plate-fin-type heat exchanger with a finer pitch fin than a conventional technology. In the first step, fabrication conditions of the ultrafine plate fin were optimized by press tests. In the second step, a brazing material was selected from several candidates through brazing tests of rods, and brazing conditions were optimized for plate-fin structures. In the third step, tensile strength, creep rupture, fatigue, and creep-fatigue tests were performed as typical strength tests for plate-fin structures. The obtained data were compared with those of the base metal and plate-fin element fabricated from SUS316. Finally, the accuracy of the creep-fatigue life prediction using both the linear cumulative damage rule and the equivalent homogeneous solid method was confirmed through the evaluation of creep-fatigue test results of plate-fin structures. (author)

  3. Evaluation of Petrifilm Lactic Acid Bacteria Plates for Counting Lactic Acid Bacteria in Food.

    Science.gov (United States)

    Kanagawa, Satomi; Ohshima, Chihiro; Takahashi, Hajime; Burenqiqige; Kikuchi, Misato; Sato, Fumina; Nakamura, Ayaka; Mohamed, Shimaa M; Kuda, Takashi; Kimura, Bon

    2018-06-01

    Although lactic acid bacteria (LAB) are used widely as starter cultures in the production of fermented foods, they are also responsible for food decay and deterioration. The undesirable growth of LAB in food causes spoilage, discoloration, and slime formation. Because of these adverse effects, food companies test for the presence of LAB in production areas and processed foods and consistently monitor the behavior of these bacteria. The 3M Petrifilm LAB Count Plates have recently been launched as a time-saving and simple-to-use plate designed for detecting and quantifying LAB. This study compares the abilities of Petrifilm LAB Count Plates and the de Man Rogosa Sharpe (MRS) agar medium to determine the LAB count in a variety of foods and swab samples collected from a food production area. Bacterial strains isolated from Petrifilm LAB Count Plates were identified by 16S rDNA sequence analysis to confirm the specificity of these plates for LAB. The results showed no significant difference in bacterial counts measured by using Petrifilm LAB Count Plates and MRS medium. Furthermore, all colonies growing on Petrifilm LAB Count Plates were confirmed to be LAB, while yeast colonies also formed in MRS medium. Petrifilm LAB Count Plates eliminated the plate preparation and plate inoculation steps, and the cultures could be started as soon as a diluted food sample was available. Food companies are required to establish quality controls and perform tests to check the quality of food products; the use of Petrifilm LAB Count Plates can simplify this testing process for food companies.

  4. Characterization of holding brake friction pad surface after pin-on-plate wear test

    Science.gov (United States)

    Drago, N.; Gonzalez Madruga, D.; De Chiffre, L.

    2018-03-01

    This article concerns the metrological characterization of the surface on a holding brake friction material pin after a pin-on-plate (POP) wear test. The POP test induces the formation of surface plateaus that affect brake performances such as wear, friction, noise and heat. Three different materials’ surfaces have been characterized after wear from data obtained with a focus variation 3D microscope. A new surface characterization approach with plateau identification is proposed, using the number of plateau on the surface, equivalent diameter, length and breadth as measurands. The identification method is based on determining and imposing ISO 27158-2 lower plateau limit (LPL) in material probability curves; and on applying a combined criterion of height segmentation threshold and equivalent diameter threshold. The method determines the criterion thresholds for each material since LPL appears typical by material. The proposed method has allowed quantifying the surface topography at two different levels of wear. An expanded measurement uncertainty of 3.5 µm for plateau dimensions in the range 50–2000 µm and one of 0.15 µm for plateau heights up to 10 µm have been documented.

  5. A method of multi-crack shape identification from eddy current testing signals of steam generator tubes including support plates as noise sources

    International Nuclear Information System (INIS)

    Nagaya, Yoshiaki; Endo, Hisashi; Takagi, Toshiyuki; Uchimoto, Tetsuya

    2005-01-01

    This paper deals with identifying multiple cracks from eddy current testing (ECT) signals obtained in a steam generator tube with a support plate and deposits. Assume two-dimensionally scanned ECT signals to be a picture image, then the signal processing by a multi-frequency technique eliminates noise caused by the support plate and deposits. A template matching with help of genetic algorithms detects number and positions of cracks from the image after the signal processing. Inverse analysis estimates the crack profile based on the predicted position of cracks. The number and positions of the cracks are sufficiently well predicted. Crack shape reconstructions are achieved with a satisfactory degree of accuracy. (author)

  6. A Development of Force Plate for Biomechanics Analysis of Standing and Walking

    Science.gov (United States)

    Wardoyo, S.; Hutajulu, P. T.; Togibasa, O.

    2016-08-01

    Force plates are known as an excellent teaching aid to demonstrate the kinematics and dynamics of motion and commonly used in biomechanics laboratories to measure ground forces involved in the motion of human. It is consist of a metal plate with sensors attached to give an electrical output proportional to the force on the plate. Moreover, force plates are useful for examining the kinetic characteristics of an athlete's movement. They provide information about the external forces involved in movement that can aid a coach or sports scientist to quantitatively evaluate the athlete's skill development. In this study, we develop our prototype of force plate with less than 100,- simply by using flexible force transducer attached inside rubber matt, in the form of square blocks (dimension: 250 mm × 150 mm × 10 mm), with maximum load up to 60 kg. The handmade force plate was tested by applying biomechanics analysis for standing and walking. The testing was done on Experimental Soccer Courses’ students at the Department of Physical Education, Health and Recreation, University of Cenderawasih. The design of the force plate system together with biomechanics analysis will be discussed.

  7. Investigations on the ultimate compressive strength of composite plates with geometrical imperfections

    DEFF Research Database (Denmark)

    Misirlis, K.; Downes, J.; Dow, R.S.

    2009-01-01

    with initial geometric imperfections. This paper presents the validation of finite element models against a series of plate tests that were performed within this framework and parametric studies that were carried out to identify the effects of geometric imperfections on the ultimate compressive strength......A series of studies has been performed within the MARSTRUCT Network of Excellence on Marine Structures in order to investigate the buckling response of glass fibre reinforced polymer plates. These studies include the fabrication, testing and finite element analysis of a large number of plates...

  8. Voltage-current characteristics of a pin-plate system with different plate configurations

    International Nuclear Information System (INIS)

    Feng, Zhuangbo; Long, Zhengwei

    2013-01-01

    In this paper, the voltage-current (V-I) characteristics of a pin-plate system with four types of collection plate configurations are studied experimentally. The collection plates consider a single metal plate, a metal plate with a fly ash cake layer, a metal plate with a clean filter media and a metal plate with a dirty filter media. The results show that the clean filter media has no obvious effect on the V-I characteristics. But the dirty filter media reduces the current density because of its high resistance. The thick fly ash cake layer increase current density because of the anti-corona effect but the increment is not very obvious.

  9. Analysis of a complex shape chain plate using Transmission Photoelasticity

    Directory of Open Access Journals (Sweden)

    Dasari N.

    2010-06-01

    Full Text Available Most chains are an assembly [1] of five parts namely, outer plate, inner plate, bush, pin and roller. Two inner plates are press fitted with two bushes to form an inner block assembly. The outer plates are press fitted with pins after keeping the pins through the assembled bushes of the inner block. Roller is a rotating member and placed over the bush during inner block assembly. Inner block assembly is the load transfer member from sprocket tooth. The outer block assembly helps in holding and also to pull the inner block over the sprocket teeth. If a chain length is in odd number of pitches, it requires an offset plate as shown in Figure 1 to connect two ends of the chain together to make chain endless. When the chain is assembled with an offset plate, the chain fatigue life was observed only 20 to 25% of the total life of a chain, assembled without an offset plate. The holes in the offset plate are of the same size as in the outer and inner plates respectively and it is a complex in shape chain plate. A inbuilt thinning zone at the centre of the chain plate as shown in Figure 1 is unavoidable. The stresses and its distribution in this complex shape chain plate geometry play a critical role in the fatigue life performance of a chain assembly. However, it is difficult identify the stress distribution and stress concentration zones precisely using only the conventional industrial friendly tools such as routine quality control test, breaking load test and numerical computations. In this context the transmission photoelastic technique has made it possible to identify the stress distribution, its concentration and also to quantify the stress and strain [2-3] at any point in the chain plate. This paper explains how transmission photoelastic technique is used to estimate the stress distribution and its concentration zones in a complex chain plate when it isloaded. An epoxy chain plate model was made through the casting method using a Perspex mould [2

  10. Experimental Study of an SWH System with V-Shaped Plate

    Directory of Open Access Journals (Sweden)

    Jalaluddin

    2016-05-01

    Full Text Available Solar energy is known as an environmentally friendly energy source with a wide range of applications. This energy can be utilized in various applications such as domestic and industrial water heating using solar water heating (SWH systems. The thermal performance of an SWH system using a V-shaped absorber plate is presented in this study. Two SWH systems with different absorber plates, i.e. a flat-plate and a V-shaped plate, have been investigated experimentally. First, the absorptivity of the absorber plates was calculated analytically. The optimum V-shaped configuration with angle at β = 21° (V-shaped dimensions t = 4 cm and l = 4 cm was determined from various V-shaped plate absorbers based on their absorptivity and applied in the experimental study. Two SWH systems were installed and tested at a low flowrate of 0.5 L/min and at a high flowrate of 2 L/min. The results showed that the SWH system with V-shaped plate absorber had a 3.6-4.4% better performance compared with that of the system with flat-plate absorber.

  11. Mechanical Behavior of BFRP-Steel Composite Plate under Axial Tension

    Directory of Open Access Journals (Sweden)

    Yunyu Li

    2014-06-01

    Full Text Available Combining the advantages of basalt fiber-reinforced polymer (BFRP material and steel material, a novel BFRP-steel composite plate (BSP is proposed, where a steel plate is sandwiched between two outer BFRP laminates. The main purpose of this research is to investigate the mechanical behavior of the proposed BSP under uniaxial tension and cyclic tension. Four groups of BSP specimens with four different BFRP layers and one control group of steel plate specimens were prepared. A uniaxial tensile test and a cyclic tensile test were conducted to determine the initial elastic modulus, postyield stiffness, yield strength, ultimate bearing capacity and residual deformation. Test results indicated that the stress-strain curve of the BSP specimen was bilinear prior to the fracture of the outer BFRP, and the BSP specimen had stable postyield stiffness and small residual deformation after the yielding of the inner steel plate. The postyield modulus of BSP specimens increased almost linearly with the increasing number of outer BFRP layers, as well as the ultimate bearing capacity. Moreover, the predicted results from the selected models under both monotonic tension and cyclic tension were in good agreement with the experimental data.

  12. Investigation on impact resistance of steel plate reinforced concrete barriers against aircraft impact. Pt.2: Simulation analysis of scale model impact tests

    International Nuclear Information System (INIS)

    Jun Mizuno; Norihide Koshika; Hiroshi Morikawa; Kentaro Wakimoto; Ryusuke Fukuda

    2005-01-01

    Steel plate reinforced concrete (SC) structure is one in which the rebars of conventional reinforced concrete (RC) structures are replaced with external steel plates attached to inner concrete with headed studs. SC structures are considered to be more effective than RC structures against aircraft impact, so their application to outer walls and roofs of risk-sensitive structures such as nuclear-related structures is expected to mitigate damage to critical components. The objective of this study was to investigate the fracture behavior and perforation thickness of SC panels against aircraft impact through impact tests and simulation analyses. Objectives of this paper are to analytically investigate the protection performance of SC panels against aircraft model impact through simulation analyses of 1/7.5 scale aircraft model impact tests presented in Part 1 of this study using a discrete element method (DEM), and to examine the applicability and validity of the DEM. Simulation analyses by a finite element method (FEM) were also performed to evaluate its applicability. The fracture process and damage to the SC test panels as well as the aircraft models are closely simulated by the discrete element analyses. The various impact responses and failure mechanisms, such as deceleration curves of projectile, velocity of debris from rear face and deformation mode of SC panels, are also simulated closely by the DEM analyses. The results of analyses confirm the shock-proof performance of SC panels against aircraft impact, and the applicability and validity of DEM for evaluating the complex phenomena of an aircraft impact against an SC panel. The finite element analysis closely simulates the deformation of the SC test panel and strains of rear steel plate where the global bending deformation mode is dominant. (authors)

  13. Biocompatibility of Bespoke 3D-Printed Titanium Alloy Plates for Treating Acetabular Fractures

    Directory of Open Access Journals (Sweden)

    Xuezhi Lin

    2018-01-01

    Full Text Available Treatment of acetabular fractures is challenging, not only because of its complicated anatomy but also because of the lack of fitting plates. Personalized titanium alloy plates can be fabricated by selective laser melting (SLM but the biocompatibility of these three-dimensional printing (3D-printed plates remains unknown. Plates were manufactured by SLM and their cytocompatibility was assessed by observing the metabolism of L929 fibroblasts incubated with culture medium extracts using a CCK-8 assay and their morphology by light microscopy. Allergenicity was tested using a guinea pig maximization test. In addition, acute systemic toxicity of the 3D-printed plates was determined by injecting extracts from the implants into the tail veins of mice. Finally, the histocompatibility of the plates was investigated by implanting them into the dorsal muscles of rabbits. The in vitro results suggested that cytocompatibility of the 3D-printed plates was similar to that of conventional plates. The in vivo data also demonstrated histocompatibility that was comparable between the two manufacturing techniques. In conclusion, both in vivo and in vitro experiments suggested favorable biocompatibility of 3D-printed titanium alloy plates, indicating that it is a promising option for treatment of acetabular fractures.

  14. Feasibility study on development of plate-type heat exchanger for BWR plants

    International Nuclear Information System (INIS)

    Ohyama, Nobuhiro; Suda, Kenichi; Ogata, Hiroshi; Matsuda, Shinichi; Nagasaka, Kazuhiro; Fujii, Toshi; Nozawa, Toshiya; Ishihama, Kiyoshi; Higuchi, Tomokazu

    2004-01-01

    In order to apply plate-type heat exchanger to RCW, TCW and FPC system in BWR plants, heat test and seismic test of RCW system heat exchanger sample were carried out. The results of these tests showed new design plate-type heat exchanger satisfied the fixed pressure resistance and seismic resistance and keep the function. The evaluation method of seismic design was constructed and confirmed by the results of tests. As anti-adhesion measure of marine organism, an ozone-water circulation method, chemical-feed method and combination of circulation of hot water and air bubbling are useful in place of the chlorine feeding method. Application of the plate-type heat exchanger to BWR plant is confirmed by these investigations. The basic principles, structure, characteristics, application limit and reliability are stated. (S.Y.)

  15. Corrosion properties of pulse-plated zinc-nickel alloy coatings

    Energy Technology Data Exchange (ETDEWEB)

    Alfantazi, A.M. [Univ. of British Columbia, Vancouver, British Columbia (Canada). Dept. of Metals and Materials Engineering; Erb, U. [Queen`s Univ., Kingston, Ontario (Canada)

    1996-11-01

    Corrosion properties of pulse-plated Zn-Ni alloy coating on a steel substrate were investigated using the neutral salt-spray test (ASTM B 117-81) and the potentiodynamic polarization technique (ASTM G 5-82). Performance of these alloy coatings with various Ni contents (up to 62 wt%) was compared to that of laboratory-prepared electrodeposited Zn coatings and commercial galvannealed (GA) steel. Results of the neutral salt-spray test indicated corrosion resistance of pulse-plated Zn-Ni alloy coatings was superior to that of the pure Zn and commercial GA coating. The Zn-20 wt% Ni and Zn-14 wt% Ni alloys gave the best protection of the Zn-Ni coatings tested. Potentiodynamic polarization tests confirmed excellent corrosion performance of the 20 wt% Ni alloy

  16. Development of stress correction formulae for heat formed steel plates

    Directory of Open Access Journals (Sweden)

    Hyung Kyun Lim

    2018-03-01

    Full Text Available The heating process such as line heating, triangular heating and so on is widely used in plate forming of shell plates found in bow and stern area of outer shell in a ship. Local shrinkage during heating process is main physical phenomenon used in plate forming process. As it is well appreciated, the heated plate undergoes the change in material and mechanical properties around heated area due to the harsh thermal process. It is, therefore, important to investigate the changes of physical and mechanical properties due to heating process in order to use them plate the design stage of shell plates. This study is concerned with the development of formula of plastic hardening constitutive equation for steel plate on which line heating is applied. In this study the stress correction formula for the heated plate has been developed based on the numerical simulation of tension test with varying plate thickness and heating speed through the regression analysis of multiple variable case. It has been seen the developed formula shows very good agreement with results of numerical simulation. This paper ends with usefulness of the present formula in examining the structural characteristic of ship's hull. Keywords: Heat input, Heat transfer analysis, Line heating, Shell plate, Stress correction, Thermo-elasto-plastic analysis

  17. Design and operation of AFC ramp plates for track clearance on longwall faces

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, I R

    1975-10-01

    A study of the use of AFC ramp plates carried out in the University of Newcastle upon Tyne is reported. A 1/4-scale ramp plate test rig was designed and the effects of pushing force, ramp plate toe angle, track width and other factors were studied.

  18. Strengthening Performance of PALF-Epoxy Composite Plate on Reinforced Concrete Beams

    Science.gov (United States)

    Chin, Siew C.; Tong, Foo S.; Doh, Shu I.; Gimbun, Jolius; Ong, Huey R.; Serigar, Januar P.

    2018-03-01

    This paper presents the effective strengthening potential of pineapple leaves fiber (PALF)-epoxy composite plate on reinforced concrete (RC) beam. At first the PALF is treated with alkali (NaOH) and its morphology is observed via scanning electron microscope (SEM). The composite plates made of PALF and epoxy with fiber loading ranging from 0.1 to 0.4 v/v was tested for its flexural behaviour. The composite was then used for external RC beam strengthening. The structural properties of RC beams were evaluated and all the beams were tested under four-point bending. It was found that the flexural strength increased as the fiber volume ratio increases. The maximum flexural strength (301.94 MPa) was obtained at the fiber volume ratio of 40%. The beam strengthened with PALF-epoxy composite plate has a 7% higher beam capacity compared to the control beam. Cracks formed at the edge of the plate of PALF-strengthened beams resulted in diagonal cracking. Result from this work shows that the PALF-epoxy composite plate has the potential to be used as external strengthening material for RC beam.

  19. Cooling a solar telescope enclosure: plate coil thermal analysis

    Science.gov (United States)

    Gorman, Michael; Galapon, Chriselle; Montijo, Guillermo; Phelps, LeEllen; Murga, Gaizka

    2016-08-01

    The climate of Haleakalā requires the observatories to actively adapt to changing conditions in order to produce the best possible images. Observatories need to be maintained at a temperature closely matching ambient or the images become blurred and unusable. The Daniel K. Inouye Solar Telescope is a unique telescope as it will be active during the day as opposed to the other night-time stellar observatories. This means that it will not only need to constantly match the ever-changing temperature during the day, but also during the night so as not to sub-cool and affect the view field of other telescopes while they are in use. To accomplish this task, plate coil heat exchanger panels will be installed on the DKIST enclosure that are designed to keep the temperature at ambient temperature +0°C/-4°C. To verify the feasibility of this and to validate the design models, a test rig has been installed at the summit of Haleakalā. The project's purpose is to confirm that the plate coil panels are capable of maintaining this temperature throughout all seasons and involved collecting data sets of various variables including pressures, temperatures, coolant flows, solar radiations and wind velocities during typical operating hours. Using MATLAB, a script was written to observe the plate coil's thermal performance. The plate coil did not perform as expected, achieving a surface temperature that was generally 2ºC above ambient temperature. This isn't to say that the plate coil does not work, but the small chiller used for the experiment was undersized resulting in coolant pumped through the plate coil that was not supplied at a low enough temperature. Calculated heat depositions were about 23% lower than that used as the basis of the design for the hillers to be used on the full system, a reasonable agreement given the fact that many simplifying assumptions were used in the models. These were not carried over into the testing. The test rig performance showing a 23% margin

  20. Migration of mineral oil from party plates of recycled paperboard into foods: 1. Is recycled paperboard fit for the purpose? 2. Adequate testing procedure.

    Science.gov (United States)

    Dima, Giovanna; Verzera, Antonella; Grob, Koni

    2011-11-01

    Party plates made of recycled paperboard with a polyolefin film on the food contact surface (more often polypropylene than polyethylene) were tested for migration of mineral oil into various foods applying reasonable worst case conditions. The worst case was identified as a slice of fried meat placed onto the plate while hot and allowed to cool for 1 h. As it caused the acceptable daily intake (ADI) specified by the Joint FAO/WHO Expert Committee on Food Additives (JECFA) to be exceeded, it is concluded that recycled paperboard is generally acceptable for party plates only when separated from the food by a functional barrier. Migration data obtained with oil as simulant at 70°C was compared to the migration into foods. A contact time of 30 min was found to reasonably cover the worst case determined in food.

  1. Thermal performance of plate-type loop thermosyphon at sub-atmospheric pressures

    International Nuclear Information System (INIS)

    Tsoi, Vadim; Chang, Shyy Woei; Chiang Kuei Feng; Huang, Chuan Chin

    2011-01-01

    This experimental study examines the thermal performance of a newly devised plate-type two-phase loop thermosyphon with cooling applications to electronic boards of telecommunication systems. The evaporation section is configured as the inter-connected multi channels to emulate the bridging boiling mechanism in pulsating thermosyphon. Two thermosyphon plates using water as the coolant with filling ratios (FR) of 0.22 and 0.32 are tested at sub-atmospheric pressures. The vapor-liquid flow images as well as the thermal resistances and effective spreading thermal conductivities are individually measured for each thermosyphon test plate at various heating powers. The high-speed digital images of the vapor-liquid flow structures reveal the characteristic boiling phenomena and the vapor-liquid circulation in the vertical thermosyphon plate, which assist to explore the thermal physics for this type of loop thermosyphon. The bubble agglomeration and pumping action in the inter-connected boiling channels take place at metastable non-equilibrium conditions, leading to the intermittent slug flows with a pulsation character. Such hybrid loop-pulsating thermosyphon permits the vapor-liquid circulation in the horizontal plate. Thermal resistances and spreading thermal conductivities detected from the present thermosyphon plates; the vapor chamber flat plate heat pipe and the copper plate at free and forced convective cooling conditions with both vertical and horizontal orientations are cross-examined. In most telecommunication systems and units, the electrical boards are vertical so that the thermal performance data on the vertical thermosyphon are most relevant to this particular application. - Highlights: → We examine thermal performances of plate-type loop thermosyphon. → Thermal resistances and spreading conductivities are examined. → Bubble agglomeration in inter-connected boiling channels generates intermittent slug flows with pulsations. → Boiling instability

  2. Experimental Study on Temperature Behavior of SSC (Stiffened Steel Plate Concrete) Structures

    International Nuclear Information System (INIS)

    Lee, K. J.; Ham, K. W.; Park, D. S.; Kwon, K. J.

    2008-01-01

    SSC(Stiffened Steel plate Concrete) module method uses steel plate instead of reinforcing bar and mold in existing RC structure. Steel plate modules are fabricated in advance, installed and poured with concrete in construction field, so construction period is remarkably shortened by SC module technique. In case of existence of temperature gap between internal and external structure surface such as containment building, thermal stress is taken place and as a result of it, structural strength is deteriorated. In this study, we designed two test specimens and several tests with temperature heating were conducted to evaluate temperature behavior of SSC structures and RC structure

  3. Corrosion behavior, mechanical properties, and long-term aging of nickel-plated uranium

    International Nuclear Information System (INIS)

    Dini, J.W.; Johnson, H.R.; Schoenfelder, C.W.

    1976-01-01

    The behavior of nickel-plated uranium upon exposure to moist nitrogen was evaluated. Plating thicknesses of 0.051 mm (2 mil) were adequate to prevent corrosion. Specimens with thinner coats showed some corrosion and some reduction in mechanical properties during subsequent testing. Plated samples exposed to dry air at ambient pressure for 10 y showed no corrosion and no degradation of mechanical properties. Surface and bulk hydrogen content, as well as free hydrogen generated during the test, were measured to determine the extent of corrosion. Results support an earlier proposed mechanism for uranium corrosion at low humidities

  4. Improvement of the corrosion resistance on Nd-Fe-B magnet with nickel plating

    International Nuclear Information System (INIS)

    Minowa, T.; Yoshikawa, M.; Honshima, M.

    1989-01-01

    The authors describe the corrosion-resistant test humidity test (80 0 C, 90%R.H.) autoclave test (120 0 C, 2atm, saturated with water vapor), salt spray test (35 0 C, 5% NaCl) performed on the sintered Nd magnet treated with nickel plating. Al ion-plating and without coating were also exposed to the corrosion test. After the specified periods of corrosion test, the permanent flux loss of the re-magnetized sample was measured. The changes in the appearance were also observed

  5. An Experimentally Validated Numerical Modeling Technique for Perforated Plate Heat Exchangers.

    Science.gov (United States)

    White, M J; Nellis, G F; Kelin, S A; Zhu, W; Gianchandani, Y

    2010-11-01

    Cryogenic and high-temperature systems often require compact heat exchangers with a high resistance to axial conduction in order to control the heat transfer induced by axial temperature differences. One attractive design for such applications is a perforated plate heat exchanger that utilizes high conductivity perforated plates to provide the stream-to-stream heat transfer and low conductivity spacers to prevent axial conduction between the perforated plates. This paper presents a numerical model of a perforated plate heat exchanger that accounts for axial conduction, external parasitic heat loads, variable fluid and material properties, and conduction to and from the ends of the heat exchanger. The numerical model is validated by experimentally testing several perforated plate heat exchangers that are fabricated using microelectromechanical systems based manufacturing methods. This type of heat exchanger was investigated for potential use in a cryosurgical probe. One of these heat exchangers included perforated plates with integrated platinum resistance thermometers. These plates provided in situ measurements of the internal temperature distribution in addition to the temperature, pressure, and flow rate measured at the inlet and exit ports of the device. The platinum wires were deposited between the fluid passages on the perforated plate and are used to measure the temperature at the interface between the wall material and the flowing fluid. The experimental testing demonstrates the ability of the numerical model to accurately predict both the overall performance and the internal temperature distribution of perforated plate heat exchangers over a range of geometry and operating conditions. The parameters that were varied include the axial length, temperature range, mass flow rate, and working fluid.

  6. A Possible Differentially Shortened Strike-slip Plate Boundary: the Okhotsk Plate Example.

    Science.gov (United States)

    Hindle, D.; Egorov, V.; Mackey, K. G.; Fujita, K.

    2004-12-01

    The Okhotsk plate has been postulated based on a combination of GPS geodetic inversions (REVEL1), seimsicity, geologic and lineament data. Lying between the North American and Eurasian plates, its northwestern corner would appear to be undergoing compression in a scissors motion between the two bounding plates. Extrusion tectonics along multiple, large strike-slip faults within the Okhotsk plate itself have been suggested to allow the escape of material away from the apex of Eurasia-North America. The plate boundary between Okhotsk and North America has been suggested to be diffuse, based on widely scattered minor seismicity. However, the large, left lateral, Ulakhan fault has also been suggested as a candidate plate boundary. We present field geological and geomorphological evidence of the partitioning of deformation between the Ulakhan fault, and several parallel and oblique, linked faults. The Ulakhan fault strand appears to have a maximum displacement of 24 km based on river valley offsets and closing large pull apart basins. Some of the displacement from the Ulakhan fault appears relayed into the plate margin along oblique trending, thrust/oblique slip faults. Estimated shortening over these faults is equivalent to the amount of shortening relayed into the plate margin from the plate boundary. There may be several thrust/oblique slip faults along the Ulakhan fault, which leads to the interesting situation of a segmented, strike-slip plate boundary being actively shortened in a margin parallel direction. This may be the result of postulated extrusion of the Okhotsk plate due to North America/Eurasia convergence. Such a situation would have important consequences for the interpretation of GPS data in a plate tectonic context.

  7. Manufacturing of a HCLL cooling plate mock up

    International Nuclear Information System (INIS)

    Rigal, E.; Dinechin, G. de; Rampal, G.; Laffont, G.; Cachon, L.

    2007-01-01

    The European DEMO blankets and associated Test Blanket Modules (TBM) are made of a set of components cooled by flowing helium at 80bar pressure. Hot Isostatic Pressing (HIP) is one of the very few processes that allow manufacturing such components exhibiting complex cooling channels. In HIP technology, the parts used to manufacture components with embedded channels are usually machined plates, blocks and tubes. Achievable geometries are limited in shape because it is not always possible to figure the channels by bent tubes. This occurs for example when channels present sharp turns, when the cross section of the channels is rectangular or when the rib between channels is so small that very thin tubes would be required. In these cases, bending is unpractical. The breeder unit cooling plates of the Helium Cooled Lithium Lead (HCLL) blanket have eight 4 x 4.5 mm parallel channels that run following a double U scheme. Turns are sharp and the wall thickness is small (1mm), so the manufacturing process described above cannot be used. An alternative process has been developed which has many advantages. It consists in machining grooves in a base plate, then closing the top of the grooves using thin welded strips, and finally adding a plate by HIP. There is then no need for the use of tubes with associated bending and deformation issues. The final component contains welds, but it must be stressed out that these potentially brittle zones do not connect the channels to the external surface because they are covered by the HIPed plate. Furthermore, the welds are homogenised during the HIP operation and further heat treatments. This paper describes the design of a simplified cooling plate mock up and its fabrication using this so-called weld+HIP process. The thermal fatigue testing of this mock up is presented somewhere else in this conference. (orig.)

  8. Loop-mediated isothermal amplification (LAMP) test for specific and rapid detection of Brucella abortus in cattle.

    Science.gov (United States)

    Karthik, K; Rathore, Rajesh; Thomas, Prasad; Arun, T R; Viswas, K N; Agarwal, R K; Manjunathachar, H V; Dhama, Kuldeep

    2014-01-01

    Brucella abortus, the major causative agent of abortion in cattle and a zoonotic pathogen, needs to be diagnosed at an early stage. Loop-mediated isothermal amplification (LAMP) test is easy to perform and also promising to be adapted at field level. To develop a LAMP assay for specific and rapid detection of B. abortus from clinical samples of cattle. LAMP primers were designed targeting BruAb2_0168 region using specific software tool and LAMP was optimized. The developed LAMP was tested for its specificity with 3 Brucella spp. and 11 other non-Brucella spp. Sensitivity of the developed LAMP was also carried out with known quantity of DNA. Cattle whole blood samples and aborted fetal stomach contents were collected and used for testing with developed LAMP assay and results were compared with polymerase chain reaction (PCR). The developed LAMP assay works at 61 °C for 60 min and the detection limit was observed to be 100-fold more than the conventional PCR that is commonly used for diagnosis of B. abortus. Clinical sensitivity and specificity of the developed LAMP assay was 100% when compared with Rose Bengal plate test and standard tube agglutination test. SYB® green dye I was used to visualize the result with naked eye. The novelty of the developed LAMP assay for specifically detecting B. abortus infection in cattle along with its inherent rapidness and high sensitivity can be employed for detecting this economically important pathogen of cattle at field level as well be exploited for screening of human infections.

  9. Seroprevalence of human brucellosis in and around Jammu, India, using different serological tests

    Directory of Open Access Journals (Sweden)

    H. K. Sharma

    2016-07-01

    Full Text Available Aim: Brucellosis is a disease of zoonotic importance as it affects both human as well as animal’s health, and therefore, directly affects animal productivity and human efficiency. Therefore, a study was conducted to estimate the seroprevalence of brucellosis in humans in Jammu and surrounding areas. Materials and Methods: A total of 121 sera samples from humans occupied with professional related to animals were collected and tested for anti-Brucella antibodies by Rose Bengal plate test (RBPT, modified RBPT (mRBPT, standard tube agglutination test (STAT, and indirect enzyme-linked immunosorbent assay (I-ELISA. Sampling was done keeping in view with the occupation, sex, and age. Results: The overall seroprevalence of brucellosis recorded was 4.96%. The test-wise seroprevalence was 9.91% by RBPT, 9.91% by mRBPT, 9.09% by STAT, and 16.52% by I-ELISA. The prevalence of brucellosis was higher in >35-50 years age group compared to >20-35 years and >50-65 years. Sex-wise seroprevalence was higher in males than females. Taking I-ELISA as standard, the relative sensitivities of mRBPT, RBPT, and I-ELISA were in the order of mRBPT=RBPT>STAT. All the tests revealed high specificity values; however, among different serological tests, I-ELISA detected a maximum number of positive sera samples. Conclusions: The prevalence of brucellosis was found to be approximately 5%. The adult (>35-50 years age male group was most vulnerable. The routine diagnosis of brucellosis involved the conventional serological tests, viz., RBPT and STAT, but each was associated with drawbacks which could give either false-positive or false-negative interpretation. Therefore, it is always recommended to use a battery of tests in the diagnosis of brucellosis.

  10. Designing Flat-Plate Photovoltaic Arrays

    Science.gov (United States)

    Ross, R. G., Jr.

    1984-01-01

    Report presents overview of state of art in design techniques for flat-plate solar photovoltaic modules and arrays. Paper discusses design requirements, design analyses, and test methods identified and developed for this technology over past several years in effort to reduce cost and improve utility and reliability for broad spectrum of terrestrial applications.

  11. Predicting the onset of dynamic instability of a cylindrical plate under axial flow conditions

    Energy Technology Data Exchange (ETDEWEB)

    Marcum, W.R., E-mail: marcumw@engr.orst.edu [Oregon State University, Department of Nuclear Engineering and Radiation Health Physics, 116 Radiation Center, Corvallis, OR 97330 (United States); Woods, B.G. [Oregon State University, Department of Nuclear Engineering and Radiation Health Physics, 116 Radiation Center, Corvallis, OR 97330 (United States)

    2012-09-15

    Highlights: Black-Right-Pointing-Pointer A semi-numerical flow induced vibration model is developed of a cylindrical plate. Black-Right-Pointing-Pointer Test case results are presented and agree well with previous studies data. Black-Right-Pointing-Pointer The model identifies a relationship between forces and the plate natural frequency. - Abstract: The dynamic mechanical stability of a single cylindrical plate under flow conditions is considered herein. Numerous plate-type research reactors such as the Advanced Test Reactor (ATR) located at the Idaho National Laboratory (INL) comprise fuel elements which contain arrays of concentrically aligned cylindrical plates. Several of these reactors are licensed to operate at extreme heat fluxes; as a corollary their hydraulic designs require large flow rates sufficient to remove this heat. These flow rates may reach superficial velocities upwards of 15 m/s through individual flow channels. Given that fuel plates typically found in such research reactors are relatively long ({approx}1.2573 m), wide ({approx}0.1397 m), and extremely thin ({approx}0.00127 m) concern is drawn toward the susceptibility of flow induced vibration (FIV). In an attempt to gain a more comprehensive understanding toward the dynamic mechanical limit of stability of cylindrical plates, a FIV model was developed using semi-numerical methods. The FIV model was developed in two separate modules; a plate stability module, and a flow module. These modules were then coupled together to produce a FIV model. In this study, a set of test cases are presented on the plate stability module under free vibration conditions, comparing well against known available information from previous studies. Results are similarly presented on the flow module and compared against a RELAP5-3D model. Lastly, results of these coupled modules are presented and discussion is given toward the relationship between plate natural frequency, geometry, and plate membrane pressures.

  12. EVALUATION OF U10MO FUEL PLATE IRRADIATION BEHAVIOR VIA NUMERICAL AND EXPERIMENTAL BENCHMARKING

    Energy Technology Data Exchange (ETDEWEB)

    Samuel J. Miller; Hakan Ozaltun

    2012-11-01

    This article analyzes dimensional changes due to irradiation of monolithic plate-type nuclear fuel and compares results with finite element analysis of the plates during fabrication and irradiation. Monolithic fuel plates tested in the Advanced Test Reactor (ATR) at Idaho National Lab (INL) are being used to benchmark proposed fuel performance for several high power research reactors. Post-irradiation metallographic images of plates sectioned at the midpoint were analyzed to determine dimensional changes of the fuel and the cladding response. A constitutive model of the fabrication process and irradiation behavior of the tested plates was developed using the general purpose commercial finite element analysis package, Abaqus. Using calculated burn-up profiles of irradiated plates to model the power distribution and including irradiation behaviors such as swelling and irradiation enhanced creep, model simulations allow analysis of plate parameters that are either impossible or infeasible in an experimental setting. The development and progression of fabrication induced stress concentrations at the plate edges was of primary interest, as these locations have a unique stress profile during irradiation. Additionally, comparison between 2D and 3D models was performed to optimize analysis methodology. In particular, the ability of 2D and 3D models account for out of plane stresses which result in 3-dimensional creep behavior that is a product of these components. Results show that assumptions made in 2D models for the out-of-plane stresses and strains cannot capture the 3-dimensional physics accurately and thus 2D approximations are not computationally accurate. Stress-strain fields are dependent on plate geometry and irradiation conditions, thus, if stress based criteria is used to predict plate behavior (as opposed to material impurities, fine micro-structural defects, or sharp power gradients), unique 3D finite element formulation for each plate is required.

  13. [Development of polyaxial locking plate screw system of sacroiliac joint].

    Science.gov (United States)

    Fan, Weijie; Xie, Xuesong; Zhou, Shuping; Zhang, Yonghu

    2014-09-01

    To develop an instrument for sacroiliac joint fixation with less injury and less complications. Firstly, 18 adult pelvic specimens (8 males and 10 females) were used to measure the anatomical data related to the locking plates and locking screws on the sacrum and ilium, and the polyaxial locking plate screw system of the sacroiliac joint was designed according to the anatomic data. This system was made of medical titanium alloy. Then 4 adult male plevic specimens were harvested and the experiment was divided into 3 groups: group A (normal pelvic), group B (the dislocated sacroiliac joint fixed with sacroiliac screws), and group C (the dislocated sacroiliac joint fixed with polyaxial locking plate screw system). The vertical displacement of sacroiliac joint under the condition of 0-700 N vertical load and the horizontal displacement on angle under the condition of 0-12 N·m torsional load were compared among the 3 groups by using the biological material test system. Finally, the simulated application test was performed on 1 adult male cadaveric specimen to observe soft tissue injury and the position of the locking plate and screw by X-ray films. According to the anatomic data of the sacrum and ilium, the polyaxial locking plate screw system of the sacroiliac joint was designed. The biomechanical results showed that the vertical displacement of the sacroiliac joint under the condition of 0-700 N vertical load in group A was significantly bigger than that in group B and group C (P 0.05). The horizontal displacement on angle under the condition of 0-12 N·m torsional load in group A was significantly less than that in group B and group C (P 0.05). The test of simulating application showed that the specimen suffered less soft tissue injury, and this instrument could be implanted precisely and safely. The polyaxial locking plate screw system of the sacroiliac joint has the advantages of smaller volume and less injury; polyaxial fixation enables flexible adjustment screw

  14. Active structural health monitoring of composite plates and sandwiches

    Directory of Open Access Journals (Sweden)

    Sadílek P.

    2013-12-01

    Full Text Available The aim of presented work is to design, assemble and test a functional system, that is able to reveal damage from impact loading. This is done by monitoring of change of spectral characteristics on a damaged structure that is caused by change of mechanical properties of material or by change of structure’s geometry. Excitation and monitoring of structures was done using piezoelectric patches. Unidirectional composite plate was tested for eigenfrequencies using chirp signal. The eigenfrequencies were compared to results from experiments with an impact hammer and consequently with results from finite element method. Same method of finding eigenfrequencies was used on a different unidirectional composite specimen. Series of impacts were performed. Spectrum of eigenfrequencies was measured on undamaged plate and then after each impact. Measurements of the plate with different level of damage were compared. Following experiments were performed on sandwich materials where more different failures may happen. Set of sandwich beams (cut out from one plate made of two outer composite layers and a foam core was investigated and subjected to several impacts. Several samples were impacted in the same manner to get comparable results. The impacts were performed with growing impact energy.

  15. Buckling analysis for structural sections and stiffened plates reinforced with laminated composites.

    Science.gov (United States)

    Viswanathan, A. V.; Soong, T.-C.; Miller, R. E., Jr.

    1972-01-01

    A classical buckling analysis is developed for stiffened, flat plates composed of a series of linked flat plate and beam elements. Plates are idealized as multilayered orthotropic elements; structural beads and lips are idealized as beams. The loaded edges of the stiffened plate are simply supported and the conditions at the unloaded edges can be prescribed arbitrarily. The plate and beam elements are matched along their common junctions for displacement continuity and force equilibrium in an exact manner. Offsets between elements are considered in the analysis. Buckling under uniaxial compressive load for plates, sections and stiffened plates is investigated. Buckling loads are found as the lowest of all possible general and local failure modes and the mode shape is used to determine whether buckling is a local or general instability. Numerical correlations with existing analysis and test data for plates, sections and stiffened plates including boron-reinforced structures are discussed. In general, correlations are reasonably good.

  16. Analysis of a Fluid-Loaded Thick Plate

    National Research Council Canada - National Science Library

    Hull, Andrew

    2002-01-01

    The physics of a thick plate with fluid loading on both sides provides the theoretical basis for insertion loss and echo reduction tests, both of which are typically used to determine how efficiently...

  17. Electromagnetic on-aircraft antenna radiation in the presence of composite plates

    Science.gov (United States)

    Kan, S. H-T.; Rojas, R. G.

    1994-01-01

    The UTD-based NEWAIR3 code is modified such that it can model modern aircraft by composite plates. One good model of conductor-backed composites is the impedance boundary condition where the composites are replaced by surfaces with complex impedances. This impedance-plate model is then used to model the composite plates in the NEWAIR3 code. In most applications, the aircraft distorts the desired radiation pattern of the antenna. However, test examples conducted in this report have shown that the undesired scattered fields are minimized if the right impedance values are chosen for the surface impedance plates.

  18. Beam test results of the first full-scale prototype of CMS RE 1/2 resistive plate chamber

    International Nuclear Information System (INIS)

    Ying Jun; Ban Yong; Ye Yanlin; Cai Jianxin; Qian Sijin; Wang Quanjin; Liu Hongtao

    2005-01-01

    The authors reported the muon beam test results of the first full-scale prototype of CMS RE 1/2 Resistive Plate Chamber (RPC). The bakelite surface is treated using a special technology without oil to make it smooth enough. The full scale RE 1/2 RPC with honeycomb supporting frame is strong and thin enough to be fitted to the limited space of CMS design for the inner Forward RPC. The muon beam test was performed at CERN Gamma Irradiation Facility (GIF). The detection efficiency of this full scale RPC prototype is >95% even at very high irradiation background. The time resolution (less than 1.2 ns) and spatial resolution are satisfactory for the muon trigger device in future CMS experiments. The noise rate is also calculated and discussed

  19. Comparative evaluation of competitive ELISA test in Colombian cattle

    International Nuclear Information System (INIS)

    Marino, O.; Rueda, E.; Sedano, L.; Zuniga, I.; Calderon, C.; Ortega, A.; Puentes, A.

    1998-01-01

    In order to contribute to the definition of the best ELISA test for screening and differential diagnosis of Brucella abortus to be applied for control programmes, a total of 2971 sera from Colombian cattle were tested for brucellosis. Conventional agglutination tests, Buffered Plate antigen test (BPAT) and Rose Bengal (RB) as well as Complement Fixation test (CFT) (Alton, et al. 1988) were used comparatively. Radial immunodiffusion test (RID) was also performed to all sera. The sera were also tested using four different ELISAs: indirect ELISA from FAO/IAEA and the indirect ELISA modified by Nielsen, et al. 1992 as well as two competitive ELISAs: one competitive ELISA used B. abortus O-polysaccharide antigen and an enzyme conjugated monoclonal to the O-polysaccharide for competition and detection. The second competitive ELISA used lipopolysaccharide (sLPS) antigen, a different monoclonal antibody for competition but also specific for the O-polysaccharide and a commercially available goat anti-mouse IgG enzyme conjugate for detection. The sera were analyzed based on its population status, 987 positive obtained from Brucella abortus infected herds based on clinical and/or bacteriological evidence and a high prevalence of brucellosis, CFT percentage of positive animals in the herd was greater than 5%. Eight hundred sixty six (866) negative sera from non-vaccinated cattle from a brucellosis free area and 1118 negative sera obtained from reglamentary vaccinated areas under a free herd program. Initial cut-off values were derived using negative serum samples. The diagnostic sensitivity and specificity was defined from frequency histograms based on this cut-off values and using 2x2 tables, corresponding confidence limits (95%) were calculated. The data were also analysed using signal detection analysis (ROC). Kappa statistics was determined for all tests and populations, accuracy was used as index of comparison to evaluate different assays. The data support the initial

  20. Impact of bearing plates dimensions on interaction of mine workings support and rock mass

    Directory of Open Access Journals (Sweden)

    Marek Rotkegel

    2015-01-01

    Full Text Available The aim of the research presented in this article is to assess the impact of bearing plates dimensions on the interaction of steel arch support and rock mass. The analysis of the bearing plates was based on laboratory tests and numerical calculations using the FLAC3D program (a finite difference method and the strain-hardening/softening model based on prescribed variations of Mohr–Coulomb properties. The article presents the results of laboratory tests on selected bearing plates and the results of numerical analysis of the interaction between the bearing plates and rock mass with coal, clay stone and sandstone properties.

  1. Effect of Plate Curvature on Blast Response of Structural Steel Plates

    Science.gov (United States)

    Veeredhi, Lakshmi Shireen Banu; Ramana Rao, N. V.; Veeredhi, Vasudeva Rao

    2018-04-01

    In the present work an attempt is made, through simulation studies, to determine the effect of plate curvature on the blast response of a door structure made of ASTM A515 grade 50 steel plates. A door structure with dimensions of 5.142 m × 2.56 m × 10 mm having six different radii of curvatures is analyzed which is subjected to blast load. The radii of curvature investigated are infinity (flat plate), 16.63, 10.81, 8.26, 6.61 and 5.56 m. In the present study, a stand-off distance of 11 m is considered for all the cases. Results showed that the door structure with smallest radius of curvature experienced least plastic deformation and yielding when compared to a door with larger radius of curvature with same projected area. From the present Investigation, it is observed that, as the radius of curvature of the plate increases, the deformation mode gradually shifts from indentation mode to flexural mode. The plates with infinity and 16.63 m radius of curvature have undergone flexural mode of deformation and plates with 6.61 and 5.56 m radius of curvature undergo indentation mode of deformation. Whereas, mixed mode of deformation that consists of both flexural and indentation mode of deformations are seen in the plates with radius of curvature 10.81 and 8.26 m. As the radius of curvature of the plate decreases the ability of the plate to mitigate the effect the blast loads increased. It is observed that the plate with smaller radius of curvature deflects most of the blast energy and results in least indentation mode of deformation. The most significant observation made in the present investigation is that the strain energy absorbed by the steel plate gets reduced to 1/3 rd when the radius of curvature is approximately equal to the stand-off distance which could be the critical radius of curvature.

  2. Thickness Measurement of Surface Attachment on Plate with Lamb Wave

    Science.gov (United States)

    Ma, Xianglong; Zhang, Yinghong; Wen, Lichao; He, Yehu

    2017-12-01

    Aiming at the thickness detection of the plate surface attachment, a nondestructive testing method based on the Lamb wave is presented. This method utilizes Lamb wave propagation characteristics of signals in a bi-layer medium to measure the surface attachment plate thickness. Propagation of Lamb wave in bi-layer elastic is modeled and analyzed. The two-dimensional simulation model of electromagnetic ultrasonic plate - scale is established. The simulation is conducted by software COMSOL for simulation analysis under different boiler scale thickness wave form curve. Through this study, the thickness of the attached material can be judged by analyzing the characteristics of the received signal when the thickness of the surface of the plate is measured.

  3. The Okhotsk Plate and the Eurasia-North America plate boundary zone.

    Science.gov (United States)

    Hindle, David; Mackey, Kevin

    2014-05-01

    The Eurasia-North America plate boundary zone transitions from spreading at rates of ~ 25mm/yr in the North Atlantic, to compression at rates of ~ 5mm/yr in the region of the Okhotsk plate. Because the pole of rotation between Eurasia and North America lies more or less on their mutual boundary, there is a linear change in rate along the boundary, and regions near the euler pole are subject to extremely low deformation rates. The Okhotsk - Eurasia - North America triple junction lies slightly south of the rotation pole, placing the Okhotsk plate entirely in a weakly contractional setting. Regions near the triple junction absorb 1mm/yr contraction. Further south, towards the shoreline of the Okhotsk sea, up to 5 mm/yr contraction may be absorbed within the plate. How shortening is accommodated across the boundary remains an open question. One possibility is wholesale extrusion of the entire Okhotsk plate (or possibly its northwestern corner) along two plate boundary strike slip faults (Eurasia-Okhostk and North America Okhotsk). The problem with this model is that the seismic record does not presently clearly support it, with the largest events distributed both within the plate interior and on its boundaries. This may suggest that instead, the Okhotsk plate, and particularly its north-western end, consists of a series of smaller blocks which shuffle against each other, partially accommodating extrusion, but also permitting some internal deformation and change of shape of the Okhotsk plate itself. We present analyses of the very sparse seismic record from the region, as well as geometric-kinematic, tectonic models of the possible deformation of northwest Okhotsk to try to better understand the different probabilities of how this slowly deforming plate boundary zone is behaving.

  4. Serotyping and analysis of produced pigments kinds by Pseudomonas aeruginosa clinical isolates

    Directory of Open Access Journals (Sweden)

    Stanković-Nedeljković Nataša

    2011-01-01

    Full Text Available Background/Aim. Pseudomonas aeruginosa (P. aeruginosa is devided into 20 serotypes on the base of the International Antigenic Typing Scheme. P. aeruginosa serotyping is important because of few reasons but epidemiological is the most important. The aim of the study was serotyping of P. aeruginosa clinical isolates, analysing of single clinical isolates P. aeruginosa present in the particular samples, and analysing of pyocianin and fluorescin production in different isolates of P. aeruginosa. Methods. A total of 223 isolates of P. aeruginosa, isolated in the microbiological laboratory of the Health Center “Aleksinac”, Aleksinac, were examinated. P. aeruginosa isolates were put on the pseudomonas isolation agar, pseudomonas agar base, acetamid agar, asparagin prolin broth, pseudomonas asparagin broth, Bushnnell-Haas agar, cetrimid agar base, King A and King B plates, plates for pyocianin production, plates for fluorescin production and tripticasa soya agar (Himedia. Polyvalent and monovalent serums were used in the agglutination (Biorad. Pigment production was analysed on the bases of growth on the plates for pyocianin and fluorescin production. Results. Serologically, we identificated the serovars as follows: O1, O3, O4, O5, O6, O7, O8, O10, O11 and O12. O1 (38% was the most often serovar, then O11 (19% and O6 (8.6%. A total of 18.6% (42 isolates did not agglutinate with any serum, whereas 21 isolates agglutinated only with polyvalent serum. The majority of P. aeruginosa isolates produced fluorescin, 129 (58.54%, 53 (22.94% produced pyocianin whereas 49 (21.21% isolates produced both pigments. Conclusion. P. aeruginosa was isolated most of the from urine, sputum and other materials. The majority often serovars were O1, O6 and O11. The most of isolates produced fluorescin (58.54%, while 22.94% producted pyocianin and 21.21% both pigments.

  5. Evaluation on Bending Properties of Biomaterial GUM Metal Meshed Plates for Bone Graft Applications

    Science.gov (United States)

    Suzuki, Hiromichi; He, Jianmei

    2017-11-01

    There are three bone graft methods for bone defects caused by diseases such as cancer and accident injuries: Autogenous bone grafts, Allografts and Artificial bone grafts. In this study, meshed GUM Metal plates with lower elasticity, high strength and high biocompatibility are introduced to solve the over stiffness & weight problems of ready-used metal implants. Basic mesh shapes are designed and applied to GUM Metal plates using 3D CAD modeling tools. Bending properties of prototype meshed GUM Metal plates are evaluated experimentally and analytically. Meshed plate specimens with 180°, 120° and 60° axis-symmetrical types were fabricated for 3-point bending tests. The pseudo bending elastic moduli of meshed plate specimens obtained from 3-point bending test are ranged from 4.22 GPa to 16.07 GPa, within the elasticity range of natural cortical bones from 2.0 GPa to 30.0 GPa. Analytical approach method is validated by comparison with experimental and analytical results for evaluation on bending property of meshed plates.

  6. An improved plating assay for determination of phage titer | Yang ...

    African Journals Online (AJOL)

    In this study, an improved plating assay was developed for detection of the number of recombinant phage Cap-T7 present in a test solution at a certain dilution point by counting the plaque forming units. The data demonstrated that the improved plating assay is fast, useful, and convenient for the determination of the phage ...

  7. Finite element analysis of a solar collector plate using two plate geometries

    Directory of Open Access Journals (Sweden)

    Diego Manuel Medina Carril

    2016-09-01

    Full Text Available The thermal behavior of an absorber plate in a solar collector is investigated using finite element analysis. The thermal behavior and efficiency of two absorber plate geometries are studied, using a typical solar collector with a rectangular profile as reference, and a proposed absorber plate with curved geometry. An analysis of the most important parameters involved in the design of the absorber plate was carried out, indicating that the curved geometry of the absorber plate yields an average efficiency ~25% higher than the conventional rectangular geometry. The results suggest that a curved profile made of materials such as aluminum with thermal conductivity higher than 200W/m°C, plate thickness of the order of 2-3mm and with a large density of tubes per unit area of the collector´s plate greatly benefits the thermal efficiency of the solar collector.

  8. Illumination estimation via thin-plate spline interpolation.

    Science.gov (United States)

    Shi, Lilong; Xiong, Weihua; Funt, Brian

    2011-05-01

    Thin-plate spline interpolation is used to interpolate the chromaticity of the color of the incident scene illumination across a training set of images. Given the image of a scene under unknown illumination, the chromaticity of the scene illumination can be found from the interpolated function. The resulting illumination-estimation method can be used to provide color constancy under changing illumination conditions and automatic white balancing for digital cameras. A thin-plate spline interpolates over a nonuniformly sampled input space, which in this case is a training set of image thumbnails and associated illumination chromaticities. To reduce the size of the training set, incremental k medians are applied. Tests on real images demonstrate that the thin-plate spline method can estimate the color of the incident illumination quite accurately, and the proposed training set pruning significantly decreases the computation.

  9. IFMIF Li target back-plate design integration and thermo-mechanical analysis

    International Nuclear Information System (INIS)

    Riccardi, B.; Roccella, S.; Micciche, G.

    2006-01-01

    The International Fusion Materials Irradiation Facility (IFMIF) is an accelerator-driven intense neutron source where fusion reactor candidate materials will be tested. The neutron flux is produced by means of a deuteron beam (current 250 mA, energy 40 MeV) that strikes a liquid lithium target circulating in a lithium loop. The support on which the liquid lithium flows, i.e. the back-plate, is the most heavily exposed component to neutron flux. A '' bayonet '' concept solution for the back-plate was proposed by ENEA with the objectives of improving the back-plate reliability and simplifying the remote handling procedures. On the base of this concept, a back-plate mock-up was fabricated and validated. Starting from the findings of the mock up design, a back-plate design integration exercise was carried out in order to check if the back-plate geometrical features are compatible with the target assembly and the Vertical Test Assemblies (VTA). The work carried out has demonstrated that even with the changes operated for the design integration (increase of in-plane dimensions and reduction of thickness) the bayonet concept is able to guarantee a tight connection to the target assembly. A thermo-mechanical analysis of the back-plate has been carried out by means of ABAQUS code. The thermal load used as input for the calculations, i.e. the neutron heat generation, has been estimated by means of Monte Carlo Mc-Delicious code. The two boundary constraint cases (full and minimum contact with target assembly) considered for each back-plate geometry option represent the extreme cases of the real operating condition of the plate. The influence of the contact heat exchange coefficient and the back-plate thickness has been also evaluated. For all these reasons, the results of the analysis can be considered as the domain of variability of the real working conditions. The results show that AISI 316L steel is not suitable as black-plate material: the stress induced in the plate, in

  10. Investigation of the timesaver process for de-burring and cleaning the plate for the Atlas Tilecalorimeter

    International Nuclear Information System (INIS)

    Guarino, V.; Kocenko, L.; Wood, K.

    1997-01-01

    The Timesaver belt grinding machine has been selected by the Atlas collaboration for deburring the master and spacer plates after die stamping and laser cutting, respectively. However, the question has been raised as to whether or not the plates are sufficiently clean after going through the Timesaver machine to immediately be glued into a submodule assembly. This would greatly enhance the production of submodules because the task of cleaning individual master and spacer plates is labor intensive and time consuming as well as raises environmental issues with the detergent that is used. In order to investigate the possibility of using the Timesaver process to clean the plates as well as debur them, several plates were run through the machine and their cleanliness inspected before and after. In addition, several glue samples were subjected to the same process, glued, and then pulled apart in an attempt to gauge the cleanliness of the plates. From this series of tests it can be concluded that the wet Timesaver machine can adequately prepare the surface of the master and spacer plates as well as clean the plates for gluing. The machine was able to adequately remove all of the oil and grime from the test plates. Also, from the single test on the dry machine it appears that significant cleaning will be required to adequately clean the plates before gluing in order to remove the remaining grit

  11. Plate removal following orthognathic surgery.

    Science.gov (United States)

    Little, Mhairi; Langford, Richard Julian; Bhanji, Adam; Farr, David

    2015-11-01

    The objectives of this study are to determine the removal rates of orthognathic plates used during orthognathic surgery at James Cook University Hospital and describe the reasons for plate removal. 202 consecutive orthognathic cases were identified between July 2004 and July 2012. Demographics and procedure details were collected for these patients. Patients from this group who returned to theatre for plate removal between July 2004 and November 2012 were identified and their notes were analysed for data including reason for plate removal, age, smoking status, sex and time to plate removal. 3.2% of plates were removed with proportionally more plates removed from the mandible than the maxilla. 10.4% of patients required removal of one or more plate. Most plates were removed within the first post-operative year. The commonest reasons for plate removal were plate exposure and infection. The plate removal rates in our study are comparable to those seen in the literature. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  12. E-Hitz: a word frequency list and a program for deriving psycholinguistic statistics in an agglutinative language (Basque).

    Science.gov (United States)

    Perea, Manuel; Urkia, Miriam; Davis, Colin J; Agirre, Ainhoa; Laseka, Edurne; Carreiras, Manuel

    2006-11-01

    We describe a Windows program that enables users to obtain a broad range of statistics concerning the properties of word and nonword stimuli in an agglutinative language (Basque), including measures of word frequency (at the whole-word and lemma levels), bigram and biphone frequency, orthographic similarity, orthographic and phonological structure, and syllable-based measures. It is designed for use by researchers in psycholinguistics, particularly those concerned with recognition of isolated words and morphology. In addition to providing standard orthographic and phonological neighborhood measures, the program can be used to obtain information about other forms of orthographic similarity, such as transposed-letter similarity and embedded-word similarity. It is available free of charge from www .uv.es/mperea/E-Hitz.zip.

  13. Implant Material, Type of Fixation at the Shaft, and Position of Plate Modify Biomechanics of Distal Femur Plate Osteosynthesis.

    Science.gov (United States)

    Kandemir, Utku; Augat, Peter; Konowalczyk, Stefanie; Wipf, Felix; von Oldenburg, Geert; Schmidt, Ulf

    2017-08-01

    To investigate whether (1) the type of fixation at the shaft (hybrid vs. locking), (2) the position of the plate (offset vs. contact) and (3) the implant material has a significant effect on (a) construct stiffness and (b) fatigue life in a distal femur extraarticular comminuted fracture model using the same design of distal femur periarticular locking plate. An extraarticular severely comminuted distal femoral fracture pattern (OTA/AO 33-A3) was simulated using artificial bone substitutes. Ten-hole distal lateral femur locking plates were used for fixation per the recommended surgical technique. At the distal metaphyseal fragment, all possible locking screws were placed. For the proximal diaphyseal fragment, different types of screws were used to create 4 different fixation constructs: (1) stainless steel hybrid (SSH), (2) stainless steel locked (SSL), (3) titanium locked (TiL), and (4) stainless steel locked with 5-mm offset at the diaphysis (SSLO). Six specimens of each construct configuration were tested. First, each specimen was nondestructively loaded axially to determine the stiffness. Then, each specimen was cyclically loaded with increasing load levels until failure. Construct Stiffness: The fixation construct with a stainless steel plate and hybrid fixation (SSH) had the highest stiffness followed by the construct with a stainless steel plate and locking screws (SSL) and were not statistically different from each other. Offset placement (SSLO) and using a titanium implant (TiL) significantly reduced construct stiffness. Fatigue Failure: The stainless steel with hybrid fixation group (SSH) withstood the most number of cycles to failure and higher loads, followed by the stainless steel plate and locking screw group (SSL), stainless steel plate with locking screws and offset group (SSLO), and the titanium plate and locking screws group (TiL) consecutively. Offset placement (SSLO) as well as using a titanium implant (TiL) reduced cycles to failure. Using the

  14. Interaction between plate make and protein in protein crystallisation screening.

    Directory of Open Access Journals (Sweden)

    Gordon J King

    Full Text Available BACKGROUND: Protein crystallisation screening involves the parallel testing of large numbers of candidate conditions with the aim of identifying conditions suitable as a starting point for the production of diffraction quality crystals. Generally, condition screening is performed in 96-well plates. While previous studies have examined the effects of protein construct, protein purity, or crystallisation condition ingredients on protein crystallisation, few have examined the effect of the crystallisation plate. METHODOLOGY/PRINCIPAL FINDINGS: We performed a statistically rigorous examination of protein crystallisation, and evaluated interactions between crystallisation success and plate row/column, different plates of same make, different plate makes and different proteins. From our analysis of protein crystallisation, we found a significant interaction between plate make and the specific protein being crystallised. CONCLUSIONS/SIGNIFICANCE: Protein crystal structure determination is the principal method for determining protein structure but is limited by the need to produce crystals of the protein under study. Many important proteins are difficult to crystallize, so that identification of factors that assist crystallisation could open up the structure determination of these more challenging targets. Our findings suggest that protein crystallisation success may be improved by matching a protein with its optimal plate make.

  15. Development of an SH Wave Magnetostrictive Transducer Module for Guided Wave Testing of Plate Structures

    International Nuclear Information System (INIS)

    Cho, Seung Hyun; Park, Jae Ha; Kwon Hyu Sang; Ahn, Bong Young; Lee, Seung Seok

    2009-01-01

    Recently much attention has been paid to a guided wave due to its effective applicability to long range and fast inspection of structures. In guided wave based NDE, the appropriate selection of wave modes is one of important factors since the test performance is highly dependent on which mode of guided waves is employed. As far as plate-like structures are concerned, so far, SH guided wave has not been frequently applied compared to Lamb waves, which is mostly caused by the lack of proper and convenient transducers to generate and measure the SH waves. In this investigation, a new small-sized SH guided wave transducer based on magnetostriction is proposed. The present transducer was designed to be modular and be used with shear couplant to avoid the inconvenience of the existing magnetostrictive patch transducers, which comprises the ferromagnetic patch tightly bonded to a structure. The wave transduction mechanism and the detailed configuration of the present transducer are presented. Experimental verification is also conducted on test specimens and the results confirm the good performance of the present transducer module

  16. Development of an SH Wave Magnetostrictive Transducer Module for Guided Wave Testing of Plate Structures

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Seung Hyun; Park, Jae Ha; Kwon Hyu Sang; Ahn, Bong Young; Lee, Seung Seok [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2009-04-15

    Recently much attention has been paid to a guided wave due to its effective applicability to long range and fast inspection of structures. In guided wave based NDE, the appropriate selection of wave modes is one of important factors since the test performance is highly dependent on which mode of guided waves is employed. As far as plate-like structures are concerned, so far, SH guided wave has not been frequently applied compared to Lamb waves, which is mostly caused by the lack of proper and convenient transducers to generate and measure the SH waves. In this investigation, a new small-sized SH guided wave transducer based on magnetostriction is proposed. The present transducer was designed to be modular and be used with shear couplant to avoid the inconvenience of the existing magnetostrictive patch transducers, which comprises the ferromagnetic patch tightly bonded to a structure. The wave transduction mechanism and the detailed configuration of the present transducer are presented. Experimental verification is also conducted on test specimens and the results confirm the good performance of the present transducer module

  17. Experimental investigation of critical velocity in a parallel plate research reactor fuel assembly

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Alfredo J.A.; Scuro, Nikolas L.; Andrade, Delvonei A., E-mail: ajcastro@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNE-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    The fuel elements of a MTR (Material Testing Reactor) type nuclear reactor are mostly composed of aluminum coated fuel plates containing the core of uranium silica (U{sub 3}Si{sub 2}) dispersed in an aluminum matrix. These plates have a thickness of the order of millimeters and are much longer in relation to their thickness. They are arranged in parallel in the assembly of the fuel element to form channels between them a few millimeters in thickness, through which there is a flow of the coolant. This configuration, combined with the need for a flow at high flow rates to ensure the cooling of the fuel element in operation, may create problems of mechanical failure of fuel plate due to the vibration induced by the flow in the channels. In the case of critical velocity excessive permanent deflections of the plates can cause blockage of the flow channel in the reactor core and lead to overheating in the plates. For this study an experimental bench capable of high volume flows and a test section that simulates a plate-like fuel element with three cooling channels were developed. The dimensions of the test section were based on the dimensions of the Fuel Element of the Brazilian Multipurpose Reactor (RMB), whose project is being coordinated by the National Commission of Nuclear Energy (CNEN). The experiments performed attained the objective of reaching Miller's critical velocity condition. The critical velocity was reached with 14.5 m/s leading to the consequent plastic deformation of the flow channel plates. (author)

  18. Embrittlement and annealing of reactor pressure vessel steels: comparison of BR3 surveillance and vessel plates to the surrogate plates representative of the Yankee Rowe vessel

    International Nuclear Information System (INIS)

    Fabry, A.; Chaouadi, T.; Puzzolante, J.L.; Van de Velde, J.; Biemiller, E.C.; Rossinski, S.T.; Carter, R.G.

    1996-07-01

    The sister pressure vessels at the BR3 and Rowe Yankee PWR plants were operated at a lower-than-usual temperature (260 degrees Celsius) and their plates were austenitized at higher-than-usual temperature (970 degrees Celsius). A heat tratemement leading to a coarser microstructure than typical for the fine grain plates that are considered in development of USNRC Regulatory guide 1.99. This material displayed outlier behaviour charackterized by a 41J CVN-shift significantly larger than predicted by Regulatory Guide 1.99. Because lower radiation temperature and nickell alloying are generally considered detrimental to irradiation sensitivity, there was a major concern that the nickel-modified lower Rowe plate and the nickel-modified BR3 plate may become too embrittled to satisfy the toughness requirements enbodied in the PTS screening criterion. This paper compares three complementary studies undertaken to clarify these uncertainties: 1) the accelerated irradiation and test program launched in 1990 by Yankee Atomic Electric Company using typical vessel plate materials containing 0.24% copper at two nickel levels: YA1, 0.63% (A533-B) and YA9, 0.19% (A302-B). These were heat-treated to produce the coarse and fine grain microstructures representative of the Yankee/BR3 and the Regulatory Guide plates, respectively, 2) the BR3 surveillance and vessel testing program: this vessel was wet-annealed in 1984, relicensed for operation till the plant shutdown in 1987, ANCL was trepanned in early 1995, 3) the accelerated irradiations in the Belgian BR2 test reactor of the Yankee coarse grain plates YA1 and YA9 together with BR3 vessel specimens extracted at nozzle elevation, a location with negligible radiation exposure. It is shown that the PTS screening criterion was never attained by the BR3 and Rowe plates, and that the BR3 vessel anneal was neither necessary nor sufficient. Finally, the sensitivity of embrittlement, annealing and post-annealing reembrittlement to irradiation

  19. Embrittlement and annealing of reactor pressure vessel steels: comparison of BR3 surveillance and vessel plates to the surrogate plates representative of the Yankee Rowe vessel

    Energy Technology Data Exchange (ETDEWEB)

    Fabry, A.; Chaouadi, T.; Puzzolante, J.L.; Van de Velde, J. [Centre de l``Etude de l``Energie Nucleaire, Mol (Belgium); Biemiller, E.C. [Yankee Atomic Electric Company, Bolton (United States); Rossinski, S.T.; Carter, R.G. [Electric Power Research Institute, Charlotte (United States)

    1996-07-01

    The sister pressure vessels at the BR3 and Rowe Yankee PWR plants were operated at a lower-than-usual temperature (260 degrees Celsius) and their plates were austenitized at higher-than-usual temperature (970 degrees Celsius). A heat tratemement leading to a coarser microstructure than typical for the fine grain plates that are considered in development of USNRC Regulatory guide 1.99. This material displayed outlier behaviour charackterized by a 41J CVN-shift significantly larger than predicted by Regulatory Guide 1.99. Because lower radiation temperature and nickell alloying are generally considered detrimental to irradiation sensitivity, there was a major concern that the nickel-modified lower Rowe plate and the nickel-modified BR3 plate may become too embrittled to satisfy the toughness requirements enbodied in the PTS screening criterion. This paper compares three complementary studies undertaken to clarify these uncertainties: 1) the accelerated irradiation and test program launched in 1990 by Yankee Atomic Electric Company using typical vessel plate materials containing 0.24% copper at two nickel levels: YA1, 0.63% (A533-B) and YA9, 0.19% (A302-B). These were heat-treated to produce the coarse and fine grain microstructures representative of the Yankee/BR3 and the Regulatory Guide plates, respectively, 2) the BR3 surveillance and vessel testing program: this vessel was wet-annealed in 1984, relicensed for operation till the plant shutdown in 1987, ANCL was trepanned in early 1995, 3) the accelerated irradiations in the Belgian BR2 test reactor of the Yankee coarse grain plates YA1 and YA9 together with BR3 vessel specimens extracted at nozzle elevation, a location with negligible radiation exposure. It is shown that the PTS screening criterion was never attained by the BR3 and Rowe plates, and that the BR3 vessel anneal was neither necessary nor sufficient. Finally, the sensitivity of embrittlement, annealing and post-annealing reembrittlement to irradiation

  20. [Comparative study on the strength of different mechanisms of operation of multidirectionally angle-stable distal radius plates].

    Science.gov (United States)

    Rausch, S; Hoffmeier, K; Gueorguiev, B G; Klos, K; Gras, F; Hofmann, G O; Mückley, T

    2011-12-01

    Polyaxial angle-stable plating is thought to be particularly beneficial in the management of complex intra-articular fractures of the distal radius. The present study was performed to investigate the strength of polyaxial locking interfaces of distal radius plates. We tested the polyaxial interfaces of 3 different distal radius plates (2.4 mm Variable Angle LCP Two-Column Volar Distal Radius Plate, Synthes, Palmar Classic, Königsee Implantate and VariAx Plate Stryker). The strength of 0° and 10° screw locking angle was obtained during static loading. The strength of Palmar Classic with a 0° locking angle is significantly the best of all tested systems. With a 10° locking angle there is no significant difference between Palmar Classic, Two column Plate and VariAx Plate. The strength of polyaxial interfaces differs between the tested systems. A reduction of ultimate strength is due to increases of screw locking angle. The design of polyaxial locking interfaces should be investigated in human bone models. © Georg Thieme Verlag KG Stuttgart · New York.

  1. Bending and stretching of plates

    CERN Document Server

    Mansfield, E H; Hemp, W S

    1964-01-01

    The Bending and Stretching of Plates deals with elastic plate theory, particularly on small- and large-deflexion theory. Small-deflexion theory concerns derivation of basic equations, rectangular plates, plates of various shapes, plates whose boundaries are amenable to conformal transformation, plates with variable rigidity, and approximate methods. Large-deflexion theory includes general equations and some exact solutions, approximate methods in large-deflexion theory, asymptotic large-deflexion theories for very thin plates. Asymptotic theories covers membrane theory, tension field theory, a

  2. Evaluation of the Minnesota Easy Culture System II Bi-Plate and Tri-Plate for identification of common mastitis pathogens in milk.

    Science.gov (United States)

    Royster, E; Godden, S; Goulart, D; Dahlke, A; Rapnicki, P; Timmerman, J

    2014-01-01

    The objective of this study was to validate use of the Minnesota Easy Culture System II Bi-Plate and Tri-Plate (University of Minnesota Laboratory for Udder Health, St. Paul) to identify common mastitis pathogens in milk. A total of 283 quarter and composite milk samples submitted to the University of Minnesota Laboratory for Udder Health during the spring of 2010 were cultured simultaneously using 3 methods: standard laboratory culture (reference method) and the Minnesota Easy Culture System II Bi-Plate and Tri-Plate methods. Bi-Plate and Tri-Plate cultures were incubated for 18 to 24h and interpreted by 2 independent, untrained readers within 5h of each other. An experienced technician completed the standard laboratory culture. For each sample, all 3 study personnel recorded the culture result (yes/no) for each of the following diagnostic categories: no bacterial growth (NG), mixed (2 organisms), contaminated (3 or more organisms), gram-positive (GP), gram-negative (GN), Staphylococcus spp., Streptococcus spp., Streptococcus agalactiae, Streptococcus dysgalactiae, Streptococcus uberis, Enterococcus spp., Staphylococcus aureus, coagulase-negative staphylococci, Escherichia coli, Klebsiella spp., and other. For each category, the prevalence, sensitivity, specificity, accuracy, and predictive values of a positive and negative test were calculated, and the agreement between readers and between each reader and the laboratory was assessed. Specificity, overall accuracy, and negative predictive values were generally high (>80%) for the Bi-Plate and Tri-Plate for each category. Sensitivity and positive predictive values were intermediate (>60%) or high (>80%) for the broad categories of NG, GP, GN, Staphylococcus spp. and Streptococcus spp., and for Staph. aureus, but were generally lower (negative predictive value for Streptococcus spp., and higher interreader agreement for some of the more specific categories. Our conclusion was that Bi-Plate and Tri-Plate results will

  3. Prevalence of Toxoplasma gondii in native donkeys in Mosul

    Directory of Open Access Journals (Sweden)

    Kh. J. Hussain

    2011-01-01

    Full Text Available The aim of the study was to determine the prevalence of Toxoplasma gondii in native donkeys in Mousl, Iraq. Fifty two sera (9 males and 43 females were examined by Latex agglutination test, Modified latex agglutination test with 2- mercaptoethanol test and Indirect ELISA test (Indirect IgG ELISA. The prevalence of Toxoplasma gondii in native donkeys was 46.15 %. Acute cases 8.33% and chronic cases 91.67 % when differentiated by Modified latex agglutination test with 2- mercaptoethanol test. The percentages of female and male infections were 51.16% (22/43 and 22.22% (2/9, respectively by using latex agglutination test, and the titeration of antibodies ranged between 1:20 - 1:1280 and for Indirect IgG ELISA it was 22.72% positive cases.

  4. New practical method for evaluation of a conventional flat plate continuous pistachio dryer

    Energy Technology Data Exchange (ETDEWEB)

    Kouchakzadeh, Ahmad [Agri Machinery Engineering, Ilam University, Ilam (Iran, Islamic Republic of); Tavakoli, Teymur [Agri Machinery Engineering, Tarbyat Modares University, Tehran (Iran, Islamic Republic of)

    2011-07-15

    Highlights: {yields} Evaluation of a conventional flat plate continuous pistachio dryer with a new feasible method. {yields} Using thermophysical properties of air and matter. {yields} This manner could be utilized in similar dryer for other agricultural products. {yields} Method shows the heat loss and power separately. -- Abstract: Testing a dryer is necessary to evaluate its absolute and comparative performance with other dryers. A conventional flat plate continuous pistachio dryer was tested by a new practical method of mass and energy equilibrium. Results showed that the average power consumption and heat loss in three tests are 62.13 and 18.99 kW, respectively. The ratio of heat loss on power consumption showed that the efficiency of practical pistachios flat plate dryer is about 69.4%.

  5. New practical method for evaluation of a conventional flat plate continuous pistachio dryer

    International Nuclear Information System (INIS)

    Kouchakzadeh, Ahmad; Tavakoli, Teymur

    2011-01-01

    Highlights: → Evaluation of a conventional flat plate continuous pistachio dryer with a new feasible method. → Using thermophysical properties of air and matter. → This manner could be utilized in similar dryer for other agricultural products. → Method shows the heat loss and power separately. -- Abstract: Testing a dryer is necessary to evaluate its absolute and comparative performance with other dryers. A conventional flat plate continuous pistachio dryer was tested by a new practical method of mass and energy equilibrium. Results showed that the average power consumption and heat loss in three tests are 62.13 and 18.99 kW, respectively. The ratio of heat loss on power consumption showed that the efficiency of practical pistachios flat plate dryer is about 69.4%.

  6. Evaluation of Thin Plate Hydrodynamic Stability through a Combined Numerical Modeling and Experimental Effort

    Energy Technology Data Exchange (ETDEWEB)

    Tentner, A. [Argonne National Lab. (ANL), Argonne, IL (United States); Bojanowski, C. [Argonne National Lab. (ANL), Argonne, IL (United States); Feldman, E. [Argonne National Lab. (ANL), Argonne, IL (United States); Wilson, E. [Argonne National Lab. (ANL), Argonne, IL (United States); Solbrekken, G [Univ. of Missouri, Columbia, MO (United States); Jesse, C. [Univ. of Missouri, Columbia, MO (United States); Kennedy, J. [Univ. of Missouri, Columbia, MO (United States); Rivers, J. [Univ. of Missouri, Columbia, MO (United States); Schnieders, G. [Univ. of Missouri, Columbia, MO (United States)

    2017-05-01

    An experimental and computational effort was undertaken in order to evaluate the capability of the fluid-structure interaction (FSI) simulation tools to describe the deflection of a Missouri University Research Reactor (MURR) fuel element plate redesigned for conversion to lowenriched uranium (LEU) fuel due to hydrodynamic forces. Experiments involving both flat plates and curved plates were conducted in a water flow test loop located at the University of Missouri (MU), at conditions and geometries that can be related to the MURR LEU fuel element. A wider channel gap on one side of the test plate, and a narrower on the other represent the differences that could be encountered in a MURR element due to allowed fabrication variability. The difference in the channel gaps leads to a pressure differential across the plate, leading to plate deflection. The induced plate deflection the pressure difference induces in the plate was measured at specified locations using a laser measurement technique. High fidelity 3-D simulations of the experiments were performed at MU using the computational fluid dynamics code STAR-CCM+ coupled with the structural mechanics code ABAQUS. Independent simulations of the experiments were performed at Argonne National Laboratory (ANL) using the STAR-CCM+ code and its built-in structural mechanics solver. The simulation results obtained at MU and ANL were compared with the corresponding measured plate deflections.

  7. Fast microchannel plate detector for particles

    International Nuclear Information System (INIS)

    Wurz, P.; Gubler, L.

    1996-01-01

    In this article we report on the timing capabilities of a new microchannel plate detector we designed and built. The detector assembly has an impedance-matched transition line (50 Ω line resistance) from anode to cable connector which is considerably smaller than other, commercially available solutions and at the same time has about four times the active area. The detector was tested with an alpha particle source and excellent time response was achieved. Using 10 μm pore size channel plates, a rise time of 300 ps and a pulse width of 520 ps are obtained. The details of the signal analysis are also given in the article. copyright 1996 American Institute of Physics

  8. Comparative evaluation of 2.3 mm locking plate system vs conventional 2.0 mm non locking plate system for mandibular condyle fracture fixation: a seven year retrospective study.

    Science.gov (United States)

    Zhang, J; Wang, X; Wu, R-H; Zhuang, Q-W; Gu, Q P; Meng, J

    2015-01-01

    This retrospective study evaluated the efficacy of a 2.3 mm locking plate/screw system compared with a 2.0-mm non-locking plate/screw system in fixation of isolated non comminuted mandibular condyle fractures. Surgical records of 101 patients who received either a 2.3 mm locking plate (group A, n = 51) or 2.0 mm non locking plate (group B, n = 50) were analyzed. All patients were followed up to a minimum of 6 months postoperatively and evaluated for hardware related complications, occlusal stability, need for and duration of MMF and mandibular functional results. Four complications occurred in the locking group and eighteen in the non locking group with complication rates equalling 8% and 36% respectively. When comparing the overall results according to plates used, the χ2 test showed a statistically significant difference between the locking and non locking plates (p Mandibular condyle fractures treated with a 2.3 mm locking plate exhibited stable osteosynthesis, were associated with minimal complications and resulted in acceptable mandibular range of motion compared with a 2.0 mm non locking plate.

  9. Development of an innovative plate-type SG for fast breeder reactor. Proposal of the concept and the evaluation of the fabricating method by the test fabrication of the partial model

    International Nuclear Information System (INIS)

    Nishi, Yoshihisa; Kinoshita, Izumi

    2006-01-01

    The concept of an innovative plate type SG for the fast reactor fabricated by using the HIP (Hot Isostatic Pressing) method was proposed. The heat transfer plate, which is assembled with rectangular tubes and is fabricated by HIP method, is surrounded by leakage detection spaces. It is possible to apply it to both the pool-type and the loop-type LMFR. In this report, the fabrication technique was studied about the concept for the loop-type LMFR, and the following results were obtained. Hip tests, tensile tests, and structure observation were performed to clarify the suitable HIP condition for the modified 9Cr-1Mo steel. As a result, the optimum condition of 1150 deg C x 1200 kgf/cm 2 x 3 hr was found. Nickel-type solder (BNi-5) and gold-type solder (BAu-4) were selected as a joining material to laminate the heat transfer tube plates. Through the comparison of tensile tests, BAu-4 that showed a more excellent joining performance was selected on the assumption of the margin of 5 mm from the welding line. After buckling load had been clarified, the BAu-4 brazing of the heat transfer tube plates was performed using a hot pressing method. Problems were not observed in the welding of simulated header, and in the fabricating of the partial model of SG. (author)

  10. BrucellaCapt versus classical tests in the serological diagnosis and management of human brucellosis.

    Science.gov (United States)

    Casanova, Aurora; Ariza, Javier; Rubio, Manuel; Masuet, Cristina; Díaz, Ramón

    2009-06-01

    The BrucellaCapt test is an immunocapture agglutination test suggested as a possible substitute for the Coombs test in the diagnosis of human brucellosis. Here it is compared with classical tests using 321 samples from 48 patients with brucellosis (6.9 +/- 1.7 samples per patient), including 20 patients with focal disease and 8 patients with a total of 9 relapse episodes (mean follow-up, 18 months). The BrucellaCapt test was used according to the manufacturer's instructions, and we also used a variant of the BrucellaCapt test in which the microtiter plates were not coated with antibodies against total human immunoglobulin (BCAPV). The correlation between the BrucellaCapt and BCAPV tests was 0.982 (P < 0.001), with 260 coincident pairs of titers (81%). The areas under the receiver operating characteristic curve for the BrucellaCapt and BCAPV tests with respect to the Coombs test were 0.969 and 0.960, respectively. Upon admission, the BrucellaCapt, BCAPV, and Coombs tests and the microagglutination test (MAT) were positive for all cases: titers were 1/2,560 by the BrucellaCapt test, 1/2,560 by the BCAPV test, 1/1,280 by the Coombs test, and 1/320 by the MAT. The decreases in the BrucellaCapt and BCAPV titers over time were pronounced in comparison with the Coombs titers. Cumulative probabilities of persistence 12 months after therapy were as follows: 80% by the BrucellaCapt test, 80% by the BCAPV test, 87% by the Coombs test, and 35% by the MAT. Serological changes during relapse were detected in seven cases (88%) by the Coombs test, in five cases by the BrucellaCapt and BCAPV tests, and in three cases by the MAT. The BrucellaCapt test is a sensitive, specific, and simple test for routine use in human brucellosis. Similar results were obtained with the BCAPV test. However, in some cases of relapse and chronic forms of the disease, the slight changes observed in low-affinity antibodies alone are better detected by the Coombs test.

  11. Development of structural design procedure of plate-fin heat exchanger for HTGR

    Energy Technology Data Exchange (ETDEWEB)

    Mizokami, Yorikata, E-mail: yorikata_mizokami@mhi.co.jp [Mitsubishi Heavy Industries, Ltd., 1-1, Wadasaki-cho 1-Chome, Hyogo-ku, Kobe 652-8585 (Japan); Igari, Toshihide [Mitsubishi Heavy Industries, Ltd., 5-717-1, Fukahori-machi, Nagasaki 851-0392 (Japan); Kawashima, Fumiko [Kumamoto University, 39-1 Kurokami 2-Chome, Kumamoto 860-8555 (Japan); Sakakibara, Noriyuki [Mitsubishi Heavy Industries, Ltd., 5-717-1, Fukahori-machi, Nagasaki 851-0392 (Japan); Tanihira, Masanori [Mitsubishi Heavy Industries, Ltd., 16-5, Konan 2-Chome, Minato-ku, Tokyo 108-8215 (Japan); Yuhara, Tetsuo [The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Hiroe, Tetsuyuki [Kumamoto University, 39-1 Kurokami 2-Chome, Kumamoto 860-8555 (Japan)

    2013-02-15

    Highlights: ► We propose high temperature structural design procedure for plate-fin heat exchanger ► Allowable stresses for brazed structures will be newly discussed ► Validity of design procedure is confirmed by carrying out partial model tests ► Proposed design procedure is applied to heat exchangers for HTGR. -- Abstract: Highly efficient plate-fin heat exchanger for application to HTGR has been focused on recently. Since this heat exchanger is fabricated by brazing a lot of plates and fins, a new procedure for structural design of brazed structures in the HTGR temperature region up to 950 °C is required. Firstly in this paper influences on material strength due to both thermal aging during brazing process and helium gas environment were experimentally examined, and failure mode and failure limit of brazed side-bar structures were experimentally clarified. Secondly allowable stresses for aging materials and brazed structures were newly determined on the basis of the experimental results. For the purpose of validating the structural design procedure including homogenization FEM modeling, a pressure burst test and a thermal fatigue test of partial model for plate-fin heat exchanger were carried out. Finally, results of reference design of plate-fin heat exchangers of recuperator and intermediate heat exchanger for HTGR plant were evaluated by the proposed design criteria.

  12. Detection of Brucella sp. infection through serological, microbiological, and molecular methods applied to buffaloes in Maranhão State, Brazil.

    Science.gov (United States)

    Dos Santos, Larissa Sarmento; Sá, Joicy Cortez; Dos Santos Ribeiro, Diego Luiz; Chaves, Nancyleni Pinto; da Silva Mol, Juliana Pinto; Santos, Renato Lima; da Paixão, Tatiane Alves; de Carvalho Neta, Alcina Vieira

    2017-04-01

    The aim of the current study is to diagnose Brucella spp. infection using methods such as serology, bacterial isolation, and molecular analysis in buffaloes bred in Maranhão State. In order to do so, 390 samples of buffalo serum were subjected to serological tests, to Rose Bengal Plate Test (RBPT) and to 2-mercaptoethanol (2-ME) combined with slow agglutination test (SAT). Vaginal swabs were collected from seropositive animals and subjected to bacterial isolation and to generic PCR. According to the serological test, 16 animals had a positive reaction to the confirmatory test (2-ME/SAT). As for bacterial isolation, three samples resulted in the isolation of Brucella spp.-characteristic colonies, which were confirmed through PCR. These results confirmed Brucella spp. infection in the buffalo herd from Maranhão State.

  13. Antibody responses measured by various serologic tests in pigs orally inoculated with low numbers of Toxoplasma gondii oocysts

    DEFF Research Database (Denmark)

    Dubey, J. P.; Andrews, C.D.; Lind, Peter

    1996-01-01

    ) infective oocysts, and 6 pigs served as uninoculated controls. Blood (serum) samples were obtained at 1- to 3-week intervals until euthanasia. At necropsy, the brain, heart, and tongue of pigs were bioassayed in mice and cats for isolation of T gondii. Modified agglutination test (MAT), using whole, fixed...

  14. Circular arc fuel plate stability experiments and analyses for the advanced neutron source

    International Nuclear Information System (INIS)

    Swinson, W.F.; Battiste, R.L.; Yahr, G.T.

    1995-08-01

    The thin fuel plates planned for the Advanced Neutron Source are to be cooled by forcing heavy water at high velocity, 25 m/s, through thin cooling channels on each side of each plate. Because the potential for structural failure of the plates is a design concern, considerable effort has been expended in assessing this potential. As part of this effort, experimental flow tests and analyses to evaluate the structural response of circular arc plates have been conducted, and the results are given in this report

  15. Investigations on brucellosis in Egyptian Baladi Does with emphasis on evaluation of diagnostic techniques.

    Science.gov (United States)

    el-Razik, K A Abd; Desouky, H M; Ahmed, W M

    2007-01-15

    Investigations were carried out on caprine brucellosis in a costal area in Egypt. A total number of 577 Baladi Does was examined for Brucella infection using different serological tests. Specimens were taken from seropositive obligatory slaughtered Does (No = 33) for Brucella isolation, histopathological examination, Polymerase Chain Reaction (PCR) assay and determination of serum copper (Cu), zinc(Zn) and iron (Fe) concentrations. Results indicated that the incidence of brucellosis was 3.0-5.0%, by using the different serological tests. Buffered Acidified Plate Antigen Test (BAPAT) is of the highest sensitivity followed by Rose Bengal Plate Test (RBPT), L-ELISA, Complement Fixation Test (CFT), P-ELISA, Rivanol test (RVT) and Tube Agglutination Test (TAT). In seropostive Does, Brucella melitensis biovar 3 was isolated from 78.78% and PCR yielded expected products in 81.81%. Moreover, granulomatous endometritis, lymphocytic mastitis and lymphoid depletion in both lymph nodes and spleen were evident together with significant (p<0.001) decreases in serum Cu, Zn and Fe concentrations. In conclusion, more attention should be paid to goat in brucellosis epidemiology in the application of national program of brucella control and eradication.

  16. Comparison of the Mechanical Characteristics of a Universal Small Biplane Plating Technique Without Compression Screw and Single Anatomic Plate With Compression Screw.

    Science.gov (United States)

    Dayton, Paul; Ferguson, Joe; Hatch, Daniel; Santrock, Robert; Scanlan, Sean; Smith, Bret

    2016-01-01

    To better understand the mechanical characteristics of biplane locked plating in small bone fixation, the present study compared the stability under cyclic cantilever loading of a 2-plate locked biplane (BPP) construct without interfragmentary compression with that of a single-plate locked construct with an additional interfragmentary screw (SPS) using surrogate bone models simulating Lapidus arthrodesis. In static ultimate plantar bending, the BPP construct failed at significantly greater load than did the SPS construct (556.2 ± 37.1 N versus 241.6 ± 6.3 N, p = .007). For cyclic failure testing in plantar bending at a 180-N starting load, the BPP construct failed at a significantly greater number of cycles (158,322 ± 50,609 versus 13,718 ± 10,471 cycles) and failure load (242.5 ± 25.0 N versus 180.0 ± 0.0 N) than the SPS construct (p = .002). For cyclic failure testing in plantar bending at a 120-N starting load, the results were not significantly different between the BPP and SPS constructs for the number of cycles (207,646 ± 45,253 versus 159,334 ± 69,430) or failure load (205.0 ± 22.4 N versus 185.0 ± 33.5 N; p = .300). For cyclic testing with 90° offset loading (i.e., medial to lateral bending) at a 120-N starting load, all 5 BPP constructs (tension side) and 2 of the 5 SPS constructs reached 250,000 cycles without failure. Overall, the present study found the BPP construct to have superior or equivalent stability in multiplanar orientations of force application in both static and fatigue testing. Thus, the concept of biplane locked plating, using 2 low profile plates and unicortical screw insertion, shows promise in small bone fixation, because it provides consistent stability in multiplanar orientations, making it universally adaptable to many clinical situations. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  17. A Study for Brucellosis Seroprevelance in Agri

    Directory of Open Access Journals (Sweden)

    Duran Tok

    2009-12-01

    Full Text Available AIM: We evaluated retrospectively laboratory test results of 520 patient who has brucellosis suspect between 2002-2004 years. METHOD: We use to Rose-Bengal test, Wright agglutination test and the other laboratory results and demographic properties for diagnosis. RESULTS: Rose-Bengal test was positive in 39 patients (11.3 % sera. Wright agglutination test was found positive for 1/160 or higher titers in 18 (3.4% sera. CONCLUSION: Wright agglutination test gave higher positive results in summer and autumn months. [TAF Prev Med Bull 2009; 8(6.000: 485-488

  18. On the relative significance of lithospheric weakening mechanisms for sustained plate tectonics

    Science.gov (United States)

    Araceli Sanchez-Maes, Sophia

    2018-01-01

    Plate tectonics requires the bending of strong plates at subduction zones, which is difficult to achieve without a secondary weakening mechanism. Two classes of weakening mechanisms have been proposed for the generation of ongoing plate tectonics, distinguished by whether or not they require water. Here we show that the energy budget of global subduction zones offers a simple yet decisive test on their relative significance. Theoretical studies of mantle convection suggest bending dissipation to occupy only 10-20 % of total dissipation in the mantle, and our results indicate that the hydrous mechanism in the shallow part of plates is essential to satisfy the requirement. Thus, surface oceans are required for the long-term operation of plate tectonics on terrestrial worlds. Establishing this necessary and observable condition for sustained plate tectonics carries important implications for planetary habitability at large.

  19. Fabrication of mandible fracture plate by indirect additive manufacturing

    Science.gov (United States)

    Aizat, M.; Khan, S. F.

    2017-10-01

    Bone fracture is a serious skeletal injury due to accidents and fragility of the bones at a certain age. In order to accelerate fracture healing process, fracture bone plate is use to hold the fracture segment for more stability. The purpose of this study is to fabricate mandibular fracture plate by using indirect additive manufacturing methods in order to reduce time taken during bending and shaping the fracture fixation plate that conform to the anatomy of the fractured bone site. The design and analysis of the plates are performed using CATIA and ANSYS software. The 3D-CAD data were sent to an additive manufacturing machine (fused filament fabricated) to generate master pattern using PLA and the mould were fabricated using Plaster of Paris. A melt ZAMAK 3 was poured directly into the moulds, and left it until completely harden. 3point bending test was performed on the prototype plate using universal testing machine. Stress-strain curve shows the graph exhibited a linear relationship of stress-strain up to a strain value of 0.001. Specimens give a maximum yielding stress and then break before the conventional deflection. Since the maximum flexural stress and the breaking stress are far apart with a plateau stating at strain value of 0.003mm/mm in most specimens, the specimen’s failure types are considered plastic failure mode. The average thickness and width are 1.65mm and 2.18mm respectively. The flexural modulus and flexural strength are 189.5GPa and 518.1MPa, respectively.

  20. False-positive cryptococcal antigen test associated with use of BBL Port-a-Cul transport vials.

    Science.gov (United States)

    Wilson, Deborah A; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S; Procop, Gary W

    2011-02-01

    A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed.

  1. 100 MW turbine foundation plate concreasting during construction of the Rovno NPP

    International Nuclear Information System (INIS)

    Presman, I.G.

    1984-01-01

    Manufacture technique and the design 1000 MW turbine foundation plate during construction of the Rovno NPP has been described. The plate dimensions are 73.7x26 m, the height is up to 5 m. The plate concrete volume is 5900 m 3 , the mass of reinforcement is 357 t. The main characteristics of concrete are presented. Tests of control samples of concrete with the age 28 and 365 days have shown the strength at compression 3540 and 4580 N/cm 2 , for axial stretch 280 and 426 N/cm 2 respectively. The change of temperature regime of the plate concrete is shown. Control results have shown the corAespondence between the design of the foundation plate and requirements to the working project

  2. History of internal fixation with plates (part 2): new developments after World War II; compressing plates and locked plates.

    Science.gov (United States)

    Hernigou, Philippe; Pariat, Jacques

    2017-07-01

    The first techniques of operative fracture with plates were developed in the 19th century. In fact, at the beginning these methods consisted of an open reduction of the fracture usually followed by a very unstable fixation. As a consequence, the fracture had to be opened with a real risk of (sometimes lethal) infection, and due to unstable fixation, protection with a cast was often necessary. During the period between World Wars I and II, plates for fracture fixation developed with great variety. It became increasingly recognised that, because a fracture of a long bone normally heals with minimal resorption at the bone ends, this may result in slight shortening and collapse, so a very rigid plate might prevent such collapse. However, as a consequence, delayed healing was observed unless the patient was lucky enough to have the plate break. One way of dealing with this was to use a slotted plate in which the screws could move axially, but the really important advance was recognition of the role of compression. After the first description of compression by Danis with a "coapteur", Bagby and Müller with the AO improved the technique of compression. The classic dynamic compression plates from the 1970s were the key to a very rigid fixation, leading to primary bone healing. Nevertheless, the use of strong plates resulted in delayed union and the osteoporosis, cancellous bone, comminution, and/or pathological bone resulted in some failures due to insufficient stability. Finally, new devices represented by locking plates increased the stability, contributing to the principles of a more biological osteosynthesis while giving enough stability to allow immediate full weight bearing in some patients.

  3. Damage initiation and growth in laminated polymer compsosite plates with fluid-structure interaction under impact loading

    Directory of Open Access Journals (Sweden)

    Y Kwon

    2016-09-01

    Full Text Available Damage initiation and growth as well as dynamic response of laminated polymer composite plates were investigated with the effect of Fluid-Structure Interaction (FSI when they were subjected to impact loading. The E-glass composite plates were clamped along the boundaries and impact loading was applied from a specially designed vertical drop-impact testing machine while the plates were surrounded by either water or air. The damage and transient responses such as force- and strain-time history were measured during the progressive impact tests, and the test data collected from either impact in air or under water were compared to determine the effect of FSI. The study showed that FSI was generally detrimental to composite plates because of the hydrodynamic mass effect so that damage occurred at a lower impact force for the composite plate submerged in water. The strain measure also suggested that the FSI effect varied from location to location of the plate surface. Additionally, the FSI effect yielded a significant change in the strain response in terms of both magnitude and shape in time history for the plate in water along with progressive damage. In summary, it is essential to include the FSI effect for design and analysis of composite structures when they are in contact with water.

  4. An experimental study of an explosively driven flat plate launcher

    Science.gov (United States)

    Rae, Philip; Haroz, Erik; Armstrong, Chris; Perry, Lee; M Division Team

    2017-06-01

    For some upcoming experiments it is desired to impact a large explosive assembly with one or more moderate diameter flat metal plates traveling at high velocity (2-3 km s-1). The time of arrival of these plates will need to carefully controlled and delayed (i.e. the time(s) of arrival known to approximately a microsecond). For this reason, producing a flyer plate from more traditional gun assemblies is not possible. Previous researchers have demonstrated the ability to throw reasonably flat metal flyers from the so-called Forest flyer geometry. The defining characteristics of this design are a carefully controlled reduction in explosive area from a larger explosive plane-wave-lens and booster pad to a smaller flyer plate to improve the planarity of the drive available and an air gap between the explosive booster and the plate to reduce the peak tensile stresses generated in the plate to suppress spalling. This experimental series comprised a number of different design variants and plate and explosive drive materials. The aim was to calibrate a predictive computational modeling capability on this kind of system in preparation for later more radical design ideas best tested in a computer before undertaking the expensive business of construction.

  5. Study of the electric field inside microchannel plate multipliers

    International Nuclear Information System (INIS)

    Gatti, E.; Oba, K.; Rehak, P.

    1982-01-01

    Electric field inside high gain microchannel plate multipliers was studied. The calculations were based directly on the solution of the Maxwell equations applied to the microchannel plate (MCP) rather than on the conventional lumped RC model. The results are important to explain the performance of MCP's, (1) under a pulsed bias tension and, (2) at high rate conditions. The results were tested experimentally and a new method of MCP operation free from the positive ion feedback was demonstrated

  6. Development of Trypanosomosis Agglutination Card Test (TACT ...

    African Journals Online (AJOL)

    In a bid to improve field diagnosis of animal trypanosomosis in tsetse-infested African countries, TACT utilizing fixed and stabilized procyclic antigen from culture-derived Trypanosoma brucei gambiense isolate IL2343 was developed and evaluated in Uganda. Its diagnostic sensitivity was evaluated using blood samples ...

  7. Latex agglutination testing in childhood bacterial meningitis ...

    African Journals Online (AJOL)

    Scientific Medical Journal. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 13, No 1 (2001) >. Log in or Register to get access to full text downloads.

  8. The Importance of Lower Mantle Structure to Plate Stresses and Plate Motions

    Science.gov (United States)

    Holt, W. E.; Wang, X.; Ghosh, A.

    2016-12-01

    Plate motions and plate stresses are widely assumed as the surface expression of mantle convection. The generation of plate tectonics from mantle convection has been studied for many years. Lithospheric thickening (or ridge push) and slab pull forces are commonly accepted as the major driving forces for the plate motions. However, the importance of the lower mantle to plate stresses and plate motions remains less clear. Here, we use the joint modeling of lithosphere and mantle dynamics approach of Wang et al. (2015) to compute the tractions originating from deeper mantle convection and follow the method of Ghosh et al. (2013) to calculate gravitational potential energy per unit area (GPE) based on Crust 1.0 (Laske et al., 2013). Absolute values of deviatoric stresses are determined by the body force distributions (GPE gradients and traction magnitudes applied at the base of the lithosphere). We use the same relative viscosity model that Ghosh et al. (2013) used, and we solve for one single adjustable scaling factor that multiplies the entire relative viscosity field to provide absolute values of viscosity throughout the lithosphere. This distribution of absolute values of lithosphere viscosities defines the magnitudes of surface motions. In this procedure, the dynamic model first satisfies the internal constraint of no-net-rotation of motions. The model viscosity field is then scaled by the single factor until we achieve a root mean square (RMS) minimum between computed surface motions and the kinematic no-net-rotation (NNR) model of Kreemer et al. (2006). We compute plate stresses and plate motions from recently published global tomography models (over 70 based on Wang et al., 2015). We find that RMS misfits are significantly reduced when details of lower mantle structure from the latest tomography models are added to models that contain only upper and mid-mantle density distributions. One of the key reasons is that active upwelling from the Large Low Shear

  9. The strength of polyaxial locking interfaces of distal radius plates.

    Science.gov (United States)

    Hoffmeier, Konrad L; Hofmann, Gunther O; Mückley, Thomas

    2009-10-01

    Currently available polyaxial locking plates represent the consequent enhancement of fixed-angle, first-generation locking plates. In contrast to fixed-angle locking plates which are sufficiently investigated, the strength of the new polyaxial locking options has not yet been evaluated biomechanically. This study investigates the mechanical strength of single polyaxial interfaces of different volar radius plates. Single screw-plate interfaces of the implants Palmar 2.7 (Königsee Implantate und Instrumente zur Osteosynthese GmbH, Allendorf, Germany), VariAx (Stryker Leibinger GmbH & Co. KG, Freiburg, Germany) und Viper (Integra LifeSciences Corporation, Plainsboro, NJ, USA) were tested by cantilever bending. The strength of 0 degrees, 10 degrees and 20 degrees screw locking angle was obtained during static and dynamic loading. The Palmar 2.7 interfaces showed greater ultimate strength and fatigue strength than the interfaces of the other implants. The strength of the VariAx interfaces was about 60% of Palmar 2.7 in both, static and dynamic loading. No dynamic testing was applied to the Viper plate because of its low ultimate strength. By static loading, an increase in screw locking angle caused a reduction of strength for the Palmar 2.7 and Viper locking interfaces. No influence was observed for the VariAx locking interfaces. During dynamic loading; angulation had no influence on the locking strength of Palmar 2.7. However, reduction of locking strength with increasing screw angulation was observed for VariAx. The strength of the polyaxial locking interfaces differs remarkably between the examined implants. Depending on the implant an increase of the screw locking angle causes a reduction of ultimate or fatigue strength, but not in all cases a significant impact was observed.

  10. Full size U-10Mo monolithic fuel foil and fuel plate fabrication-technology development

    International Nuclear Information System (INIS)

    Moore, G.A.; Jue, J-F.; Rabin, B.H.; Nilles, M.J.

    2010-01-01

    Full-size U-10Mo foils are being developed for use in high density LEU monolithic fuel plates. The application of a zirconium barrier layer to the foil is performed using a hot co-rolling process. Aluminium clad fuel plates are fabricated using Hot Isostatic Pressing (HIP) or a Friction Bonding (FB) process. An overview is provided of ongoing technology development activities, including: the co-rolling process, foil shearing/slitting and polishing, cladding bonding processes, plate forming, plate-assembly swaging, and fuel plate characterization. Characterization techniques being employed include, Ultrasonic Testing (UT), radiography, and microscopy. (author)

  11. AN INITIAL EVALUATION OF THE BTRACKS BALANCE PLATE AND SPORTS BALANCE SOFTWARE FOR CONCUSSION DIAGNOSIS.

    Science.gov (United States)

    Goble, Daniel J; Manyak, Kristin A; Abdenour, Thomas E; Rauh, Mitchell J; Baweja, Harsimran S

    2016-04-01

    As recently dictated by the American Medical Society, balance testing is an important component in the clinical evaluation of concussion. Despite this, previous research on the efficacy of balance testing for concussion diagnosis suggests low sensitivity (∼30%), based primarily on the popular Balance Error Scoring System (BESS). The Balance Tracking System (BTrackS, Balance Tracking Systems Inc., San Diego, CA, USA) consists of a force plate (BTrackS Balance Plate) and software (BTrackS Sport Balance) which can quickly (balance testing with gold standard accuracy. The present study aimed to determine the sensitivity of the BTrackS Balance Plate and Sports Balance Software for concussion diagnosis. Cross-Sectional Study. Preseason baseline balance testing of 519 healthy Division I college athletes playing sports with a relatively high risk for concussions was performed with the BTrackS Balance Test. Testing was administered by certified athletic training staff using the BTrackS Balance Plate and Sport Balance software. Of the baselined athletes, 25 later experienced a concussion during the ensuing sport season. Post-injury balance testing was performed on these concussed athletes within 48 of injury and the sensitivity of the BTrackS Balance Plate and Sport Balance software was estimated based on the number of athletes showing a balance decline according to the criteria specified in the Sport Balance software. This criteria is based on the minimal detectable change statistic with a 90% confidence level (i.e. 90% specificity). Of 25 athletes who experienced concussions, 16 had balance declines relative to baseline testing results according to the BTrackS Sport Balance software criteria. This corresponds to an estimated concussion sensitivity of 64%, which is twice as great as that reported previously for the BESS. The BTrackS Balance Plate and Sport Balance software has the greatest concussion sensitivity of any balance testing instrument reported to date. Level 2

  12. Catalysts characteristics of Ni/YSZ core-shell according to plating conditions using electroless plating

    Science.gov (United States)

    Park, Hyun-Wook; Jang, Jae-Won; Lee, Young-Jin; Kim, Jin-Ho; Jeon, Dae-Woo; Lee, Jong-Heun; Hwang, Hae-jin; Lee, Mi-Jai

    2017-11-01

    This study aims to develop an anode catalyst for a solid oxide fuel cell (SOFC) using electroless nickel plating. We have proposed a new method for electroless plating of Ni metal on yttria-stabilized zirconia (YSZ) particles. We examine the uniformity of the Ni layer on the plated core-shell powder, in addition to the content of Ni and the reproducibility of the plating. We have also evaluated the carbon deposition rate and characteristics of the SOFC anode catalyst. To synthesize Ni-plated YSZ particles, the plated powder is heat-treated at 1200 °C. The resultant particles, which have an average size of 50 μm, were subsequently used in the experiment. The size of the Ni particles and the Ni content both increase with increasing plating temperature and plating time. The X-ray diffraction pattern reveals the growth of Ni particles. After heat-treatment, Ni is oxidized to NiO, leading to the co-existence of Ni and NiO; Ni3P is also observed due to the presence of phosphorous in the plating solution. Following heat treatment for 1 h at 1200 °C, Ni is mostly oxidized to NiO. The carbon deposition rate of the reference YSZ powder is 135%, while that of the Ni-plated YSZ is 1%-6%.

  13. Simplified design of flexible expansion anchored plates for nuclear structures

    International Nuclear Information System (INIS)

    Mehta, N.K.; Hingorani, N.V.; Longlais, T.G.; Sargent and Lundy, Chicago, IL)

    1984-01-01

    In nuclear power plant construction, expansion anchored plates are used to support pipe, cable tray and HVAC duct hangers, and various structural elements. The expansion anchored plates provide flexibility in the installation of field-routed lines where cast-in-place embedments are not available. General design requirements for expansion anchored plate assemblies are given in ACI 349, Appendix B (1). The manufacturers recommend installation procedures for their products. Recent field testing in response to NRC Bulletin 79-02 (2) indicates that anchors, installed in accordance with manufacturer's recommended procedures, perform satisfactorily under static and dynamic loading conditions. Finite element analysis is a useful tool to correctly analyze the expansion anchored plates subject to axial tension and biaxial moments, but it becomes expensive and time-consuming to apply this tool for a large number of plates. It is, therefore, advantageous to use a simplified method, even though it may be more conservative as compared to the exact method of analysis. This paper presents a design method referred to as the modified rigid plate analysis approach to simplify both the initial design and the review of as-built conditions

  14. Field evaluation of a fast anti-Leishmania antibody detection assay in Ethiopia

    NARCIS (Netherlands)

    Hailu, A.; Schoone, G. J.; Diro, E.; Tesfaye, A.; Techane, Y.; Tefera, T.; Assefa, Y.; Genetu, A.; Kebede, Y.; Kebede, T.; Schallig, H. D. F. H.

    2006-01-01

    A fast agglutination screening test (FAST) for the detection of Leishmania antibodies in human serum samples was evaluated under harsh field conditions in northern Ethiopia. Test performance was compared with a standard serological test, namely the direct agglutination test (DAT), and with

  15. Fuel cell end plate structure

    Science.gov (United States)

    Guthrie, Robin J.; Katz, Murray; Schroll, Craig R.

    1991-04-23

    The end plates (16) of a fuel cell stack (12) are formed of a thin membrane. Pressure plates (20) exert compressive load through insulation layers (22, 26) to the membrane. Electrical contact between the end plates (16) and electrodes (50, 58) is maintained without deleterious making and breaking of electrical contacts during thermal transients. The thin end plate (16) under compressive load will not distort with a temperature difference across its thickness. Pressure plate (20) experiences a low thermal transient because it is insulated from the cell. The impact on the end plate of any slight deflection created in the pressure plate by temperature difference is minimized by the resilient pressure pad, in the form of insulation, therebetween.

  16. Moment Capacity of Timber Reinforced with Punched Metal Plate Fasteners

    DEFF Research Database (Denmark)

    Nielsen, Jacob; Ellegaard, Peter

    When designing timber trusses it is often found that the cross section controlling the dimensions of the top chord is located at a joint with a moment peak. However, the timber volume affected by the moment peak is rather limited and by embedding a punched metal plate in this area a reinforcement...... of the section is obtained, resulting in a more economic truss design. In order to develop design methods for sections with plate reinforcement, bending tests have been made. The timber is Swedish spruce of strength class K-18(S8) and K-24(S10) with a thickness of 45 mm. The punched metal plate is from Gang...

  17. The analysis of the accuracy of the wheel alignment inspection method on the side-slip plate stand

    Science.gov (United States)

    Gajek, A.; Strzępek, P.

    2016-09-01

    The article presents the theoretical basis and the results of the examination of the wheel alignment inspection method on the slide slip plate stand. It is obligatory test during periodic technical inspection of the vehicle. The measurement is executed in the dynamic conditions. The dependence between the lateral displacement of the plate and toe-in of the tested wheels has been shown. If the diameter of the wheel rim is known then the value of the toe-in can be calculated. The comparison of the toe-in measurements on the plate stand and on the four heads device for the wheel alignment inspection has been carried out. The accuracy of the measurements and the influence of the conditions of the tests on the plate stand (the way of passing through the plate) were estimated. The conclusions about the accuracy of this method are presented.

  18. The cell agglutination agent, phytohemagglutinin-L, improves the efficiency of somatic nuclear transfer cloning in cattle (Bos taurus).

    Science.gov (United States)

    Du, Fuliang; Shen, Perng-Chih; Xu, Jie; Sung, Li-Ying; Jeong, B-Seon; Lucky Nedambale, Tshimangadzo; Riesen, John; Cindy Tian, X; Cheng, Winston T K; Lee, Shan-Nan; Yang, Xiangzhong

    2006-02-01

    One of the several factors that contribute to the low efficiency of mammalian somatic cloning is poor fusion between the small somatic donor cell and the large recipient oocyte. This study was designed to test phytohemagglutinin (PHA) agglutination activity on fusion rate, and subsequent developmental potential of cloned bovine embryos. The toxicity of PHA was established by examining its effects on the development of parthenogenetic bovine oocytes treated with different doses (Experiment 1), and for different durations (Experiment 2). The effective dose and duration of PHA treatment (150 microg/mL, 20 min incubation) was selected and used to compare membrane fusion efficiency and embryo development following somatic cell nuclear transfer (Experiment 3). Cloning with somatic donor fibroblasts versus cumulus cells was also compared, both with and without PHA treatment (150 microg/mL, 20 min). Fusion rate of nuclear donor fibroblasts, after phytohemagglutinin treatment, was increased from 33 to 61% (P cell nuclear donors. The nuclear transfer (NT) efficiency per oocyte used was improved following PHA treatment, for both fibroblast (13% versus 22%) as well as cumulus cells (17% versus 34%; P cloned embryos, both with and without PHA treatment, were subjected to vitrification and embryo transfer testing, and resulted in similar survival (approximately 90% hatching) and pregnancy rates (17-25%). Three calves were born following vitrification and embryo transfer of these embryos; two from the PHA-treated group, and one from non-PHA control group. We concluded that PHA treatment significantly improved the fusion efficiency of somatic NT in cattle, and therefore, increased the development of cloned blastocysts. Furthermore, within a determined range of dose and duration, PHA had no detrimental effect on embryo survival post-vitrification, nor on pregnancy or calving rates following embryo transfer.

  19. Multi-objective room acoustic optimization of timber folded plate structure

    DEFF Research Database (Denmark)

    Skov, Rasmus; Parigi, Dario; Damkilde, Lars

    2017-01-01

    This paper investigates the application of multi-objective optimization in the design of timber folded plate structures in the scope of the architectural design process. Considering contrasting objectives of structural displacement, early decay time (EDT), clarity (C50) and sound strength (G......), the methodology applied in two benchmarks tests, encompasses both structural and acoustic performance when determining folding characteristics and directionality of surfaces in a timber folded plate structure....

  20. Heat insulating plates

    Energy Technology Data Exchange (ETDEWEB)

    Allan, J.A.F.

    1976-10-28

    Micro-porous insulation plates are dealt with, for example, how they are used in the insulation of heat storage devices. Since one side of such plates is exposed to a temperature of over 700/sup 0/C, a shrinkage of the glass texture of the covering can occur, which can exceed the shrinkage of the inner micro-porous material, so that cracks and splits in the high temperature side of the covering can come about. The task of the invention is to design the plate in such a way as to prevent this from happening. For this purpose the plate is provided, according to invention specifications, with flutes, waves, ribs, waffle or grid patterns and the covering is set into the recesses originating from this.

  1. Equivalent properties for perforated plates. An analytical approach

    International Nuclear Information System (INIS)

    Cepkauskas, M.M.; Yang Jianfeng

    2005-01-01

    Structures that contain perforated plates have been a subject of interest in the Nuclear Industry. Steam generators, condensers and reactor internals utilize plates containing holes which act as flow holes or separate structures from flow by using a 'tube bank' design. The equivalent plate method has been beneficial in analyzing perforate plates. Details are found in various papers found in the bibliography. In addition the ASME code addresses perforated plates in Appendix A-8000, but is limited to a triangular hole pattern. This early work performed in this field utilized test data and analytical approaches. This paper is an examination of an analytical approach for determining equivalent plate mechanical and thermal properties. First a patch of the real plate is identified that provides a model for the necessary physical behavior of the plate. The average strain of this patch is obtained by first applying simplified one dimensional mechanical load to the patch, determining stress as a function of position, converting the stress to strain and then integrating the strain over the patch length. This average strain is then equated to the average strain of an equivalent fictitious rectangular patch. This results in obtaining equivalent Young's Modulus and Poison's Ratio for the equivalent plate in all three orthogonal directions. The corresponding equivalent shear modulus in all three directions is then determined. An orthotropic material stress strain matrix relationship is provided for the fictitious properties. By equating the real average strain with the fictitious average strain in matrix form, a stress multiplier is found to convert average fictitious stress to average real stress. This same type of process is repeated for heat conduction coefficients and coefficients of thermal expansion. Results are provided for both a square and triangular hole pattern. Reasonable results are obtained when comparing the effective Young's Modulus and Poison's Ratio with ASME

  2. Heat analysis of the magnetic limiter plate for JT-60

    International Nuclear Information System (INIS)

    Nakamura, Hiroo; Ninomiya, Hiromasa; Shimizu, Masatsugu; Ohta, Mitsuru

    1977-03-01

    Heat analysis has been made of the magnetic limiter plate for JT-60. Test materials of the magnetic limiter plate are molybdenum, graphite, pyrolytic graphite and silicon carbide. It is assumed in calculation of the heat analysis that 10MW is deposited on the 2 cm wide surface of the magnetic limiter plate in about 10 sec. The magnetic limiter plate of pyrolytic graphite is a stack of pyrolytic graphite sheets, heat input is in the deposition plane to take advantage of the large heat conductivity along this plane. Pyrolytic graphite is the best in terms of temperature rise. The temperature of molybdenum and graphite rise up to 1800 0 C and 620 0 C, respectively, in an deposition of 10 MWx10sec. Silicon carbide is not suitable for the magnetic limiter plate. Because the plasma of the JT-60 discharges every 10 min, the average heat flux decreases to 17 w/cm 2 during the each interval. When the magnetic limiter plate has the above heat inflow, a maximum of above 1000 0 C occurs at the edge far from the joint to the thick ring of the vacuum vessel. To reduce heat load of the magnetic limiter plate, an alternating current (2 -- 5Hz) is superposed on the magnetic limiter coil current. The intersection of separatrix line and magnetic limiter plate then moves cyclically more than 10 cm. Concerning temperature distribution of the multi-groove magnetic limiter plate, its dimensions are determined by the limitation in vapor pressure to prevent the impurity inflow. (auth.)

  3. Electroless Ni-B plating for electrical contact applications

    Directory of Open Access Journals (Sweden)

    Dervos, C. T.

    2005-12-01

    Full Text Available Electroless Ni-B plating has been tried on steel substrate in an effort to employ low-cost starting materials for electrical contacts or connectors. By selected conditions of heat treatment in a high vacuum environment the plating can acquire Cr-equivalent hardness without the effluents of the hard chromium plating process. The surfaces were characterized under scanning electron microscope and by XRD. The fabricated materials were tested under corrosion conditions by polarization measurements. Semispherical nickel plated steel joints were tested in a computer controlled contact make-break apparatus, under simultaneous application of a mechanical and a low-voltage electrical load for 20,000 cycles. After heat treatment the plating acquires a crystalline structure with very good adhesion to the substrate material. Corrosion decreases and increased hardness is obtained. The surface is also characterized by good electrical properties during aging accelerated tests.

    Se ha investigado la deposición de Ni-B por vía química sobre un substrato de acero, con el fin de poder emplear materiales de bajo coste para los contactos o conectores eléctricos. Mediante condiciones específicas de tratamiento térmico en un ambiente de alto vacío, la deposición puede alcanzar durezas equivalentes al cromo (Cr sin los efluentes del proceso de cromado duro. Las superficies se caracterizaron en el microscopio electrónico de barrido y mediante DRX. Los materiales fabricados se ensayaron bajo condiciones de corrosión utilizando mediciones de polarización. Se ensayaron las juntas semiesféricas de acero niquelado en un equipo de contactos controlado por ordenador bajo la aplicación simultánea de una carga mecánica y de una carga eléctrica de bajo voltaje durante 20.000 ciclos. Después del tratamiento térmico, el recubrimiento adquiere una estructura cristalina con muy buena adherencia al material del substrato. Se consigue una menor corrosión y mayor

  4. Fuel cell cooler-humidifier plate

    Science.gov (United States)

    Vitale, Nicholas G.; Jones, Daniel O.

    2000-01-01

    A cooler-humidifier plate for use in a proton exchange membrane (PEM) fuel cell stack assembly is provided. The cooler-humidifier plate combines functions of cooling and humidification within the fuel cell stack assembly, thereby providing a more compact structure, simpler manifolding, and reduced reject heat from the fuel cell. Coolant on the cooler side of the plate removes heat generated within the fuel cell assembly. Heat is also removed by the humidifier side of the plate for use in evaporating the humidification water. On the humidifier side of the plate, evaporating water humidifies reactant gas flowing over a moistened wick. After exiting the humidifier side of the plate, humidified reactant gas provides needed moisture to the proton exchange membranes used in the fuel cell stack assembly. The invention also provides a fuel cell plate that maximizes structural support within the fuel cell by ensuring that the ribs that form the boundaries of channels on one side of the plate have ends at locations that substantially correspond to the locations of ribs on the opposite side of the plate.

  5. Influence of the wavelet order on proper damage location in plate structures

    Science.gov (United States)

    Pawlak, Zdzisław; Knitter-Piątkowska, Anna

    2018-01-01

    The rectangular thin plates were analyzed in the paper. The static response in plate structure subjected to the uniform load was derived by applying the finite element method. In the dynamic, experimental tests the accelerations were obtained with the use of modal hammer and DEWEsoft® software. Next, the analysis of the signal was carried out with the use of Discrete Wavelet Transform (DWT), provided that damage exists in the considered plate structure. It was assumed, that in the middle of the structure a certain area of the plate is thinner or there is a crack across the entire plate thickness. The aim of this work was to choose the appropriate wavelet order to reveal the localization of defect. The results of selected numerical example proved the efficiency of proposed approach.

  6. Theroretical modelling of the plate-tubes coupling in the hydroelasticity of the perforated plates

    International Nuclear Information System (INIS)

    Dzhupanov, V.A.; Manoach, E.S.

    1983-01-01

    In the previous investigations on the perforated plate hydroelasticity the problem of the plates-tubes-liquid interaction in the process of the general structural vibration is stated. But the interaction of the vibrating plates with the tubes, passing through them, is taken into account considering the tubes only as absolutely rigid supports. This is one of the possible technical realizations. In the present article the case when the tubes are taking part in the plate motion (vibration) is studied. Two circular perforated plates are supported by the absolutely rigid wall of the modelled roundcircular reactor barrel. The distance between the plates is given. They are connected by tubes, passing through, and clamped into the perforation holes. The plates and the tubes are made by any elastic HOOKIAN material. The volume between the two plates and outwardly to the tubes, but intrinsically of the barrel is filled by ideal, compressible and heavy liquid. Evidently the liquid volume is multiconnected one. The free vibration of the whole system is considered with the purposes: i) to give a theoretical model of the plates-tubes-liquid interaction including governing equations and boundary conditions; ii) to trace the solution of the eigen-value problem for the modelled structure; iii) to underline the engineering sides of the modelling process. (orig./GL)

  7. Modeling of parallel-plate regenerators with non-uniform plate distributions

    DEFF Research Database (Denmark)

    Jensen, Jesper Buch; Engelbrecht, Kurt; Bahl, Christian Robert Haffenden

    2010-01-01

    plate spacing distributions are presented in order to understand the impact of spacing non-uniformity. Simulations of more realistic distributions where the plate spacings follow normal distributions are then discussed in order to describe the deviation of the performance of a regenerator relative...

  8. Development plates for stable internal fixation: Study of mechanical resistance in simulated fractures of the mandibular condyle.

    Science.gov (United States)

    Celegatti Filho, Tóride Sebastião; Rodrigues, Danillo Costa; Lauria, Andrezza; Moreira, Roger William Fernandes; Consani, Simonides

    2015-01-01

    To develop Y-shaped plates with different thicknesses to be used in simulated fractures of the mandibular condyle. Ten plates were developed in Y shape, containing eight holes, and 30 synthetic polyurethane mandible replicas were developed for the study. The load test was performed on an Instron Model 4411 universal testing machine, applying load in the mediolateral and anterior-posterior positions on the head of the condyle. Two-way ANOVA with Tukey testing with a 5% significance level was used. It was observed that when the load was applied in the medial-lateral plate of greater thickness (1.5 mm), it gave the highest strength, while in the anteroposterior direction, the plate with the highest resistance was of the lesser thickness (0.6 mm). A plate with a thickness of 1.5 mm was the one with the highest average value for all displacements. In the anteroposterior direction, the highest values of resistance were seen in the displacement of 15 mm. After comparing the values of the biomechanical testing found in the scientific literature, it is suggested that the use of Y plates are suitable for use in subcondylar fractures within the limitations of the study. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  9. Highly conductive composites for fuel cell flow field plates and bipolar plates

    Science.gov (United States)

    Jang, Bor Z; Zhamu, Aruna; Song, Lulu

    2014-10-21

    This invention provides a fuel cell flow field plate or bipolar plate having flow channels on faces of the plate, comprising an electrically conductive polymer composite. The composite is composed of (A) at least 50% by weight of a conductive filler, comprising at least 5% by weight reinforcement fibers, expanded graphite platelets, graphitic nano-fibers, and/or carbon nano-tubes; (B) polymer matrix material at 1 to 49.9% by weight; and (C) a polymer binder at 0.1 to 10% by weight; wherein the sum of the conductive filler weight %, polymer matrix weight % and polymer binder weight % equals 100% and the bulk electrical conductivity of the flow field or bipolar plate is at least 100 S/cm. The invention also provides a continuous process for cost-effective mass production of the conductive composite-based flow field or bipolar plate.

  10. Measurements of Conversion Efficiency for a Flat Plate Thermophotovoltaic System Using a Photonic Cavity Test System

    International Nuclear Information System (INIS)

    Brown, E.J.; Ballinger, C.T.; Burger, S.R.; Charache, G.W.; Danielson, L.R.; DePoy, D.M.; Donovan, T.J.; LoCascio, M.

    2000-01-01

    The performance of a 1 cm 2 thermophotovoltaic (TPV) module was recently measured in a photonic cavity test system. A conversion efficiency of 11.7% was measured at a radiator temperature of 1076 C and a module temperature of 29.9 C. This experiment achieved the highest direct measurement of efficiency for an integrated TPV system. Efficiency was calculated from the ratio of the peak (load matched) electrical power output and the heat absorption rate. Measurements of these two parameters were made simultaneously to assure the validity of the measured efficiency value. This test was conducted in a photonic cavity which mimicked a typical flat-plate TPV system. The radiator was a large, flat graphite surface. The module was affixed to the top of a copper pedestal for heat absorption measurements. The heat absorption rate was proportional to the axial temperature gradient in the pedestal under steady-state conditions. The test was run in a vacuum to eliminate conductive and convective heat transfer mechanisms. The photonic cavity provides the optimal test environment for TPV efficiency measurements because it incorporates all important physical phenomena found in an integrated TPV system: high radiator emissivity and blackbody spectral shape, photon recycling, Lambertian distribution of incident radiation and complex geometric effects. Furthermore, the large aspect ratio between radiating surface area and radiator/module spacing produces a view factor approaching unity with minimal photon leakage

  11. Time reversal focusing of elastic waves in plates for an educational demonstration.

    Science.gov (United States)

    Heaton, Christopher; Anderson, Brian E; Young, Sarah M

    2017-02-01

    The purpose of this research is to develop a visual demonstration of time reversal focusing of vibrations in a thin plate. Various plate materials are tested to provide optimal conditions for time reversal focusing. Specifically, the reverberation time in each plate and the vibration coupling efficiency from a shaker to the plate are quantified to illustrate why a given plate provides the best spatially confined focus as well as the highest focal amplitude possible. A single vibration speaker and a scanning laser Doppler vibrometer (SLDV) are used to provide the time reversal focusing. Table salt is sprinkled onto the plate surface to allow visualization of the high amplitude, spatially localized time reversal focus; the salt is thrown upward only at the focal position. Spatial mapping of the vibration focusing on the plate using the SLDV is correlated to the visual salt jumping demonstration. The time reversal focusing is also used to knock over an object when the object is placed at the focal position; some discussion of optimal objects to use for this demonstration are given.

  12. Residual strains in a stainless steel perforated plate subjected to reverse loading at high temperature

    International Nuclear Information System (INIS)

    Durelli, A.J.; Buitrago, J.

    1974-01-01

    An investigation was made to determine strains in a stainless steel perforated plate subjected to a temperature of 1100 0 F and to a successively applied tensile and compressive in-plane loading sufficiently large to produce creep and plastic strains. The duration of the test was 1000 hours. Square grids of lines (at distance of 0.25 in.) and crossed-gratings (500 lines-per-inch) were engraved on both surfaces of the plate before the test. After the plate was unloaded and brought back to room temperature the grids were analyzed using traveling microscopes, and the gratings using the moire effect. Both Cartesian strains were determined from the moire isothetics along the axes of the plate, along the two lines tangent to the hole and parallel to those axes and along the edges of the plate. Grid measurements were made at specific points. The deformed shapes of the hole and of the plate are also given. It is estimated that strains larger than 0.001 can be determined with the techniques and methods used. (U.S.)

  13. Experimental and numerical study of the wave run-up along a vertical plate

    DEFF Research Database (Denmark)

    Molin, Bernard; Kimmoun, O.; Liu, Y.

    2010-01-01

    Results from experiments on wave interaction with a rigid vertical plate are reported. The 5m long plate is set against the wall of a 30m wide basin, at 100m from the wavemaker. This set-up is equivalent to a 10m plate in the middle of a 60m wide basin. Regular waves are produced, with wavelength...... on extended Boussinesq equations. In most of the experimental tests, despite the large distance from the wavemaker to the plate and the small amplitude of the incident wave, no steady state is attained by the end of the exploitable part of the records....

  14. Fabrication and mechanical test data for the four 6-inch-thick intermediate test vessels made from steel plate for the Heavy Section Steel Program

    International Nuclear Information System (INIS)

    Childress, C.E.

    1976-01-01

    The HSST Program has among its goals the objective of demonstrating the capability to predict safe behavior of thick-walled pressure vessels containing flaws of known dimensions under frangible, transitional, and tough loading regimes. To accomplish these objectives the program is conducting a series of tests involving 6-in.-thick pressure vessels which will serve as test specimens for assisting in the characterization of failure under these loading conditions. Among the vessels a number of parameters, such as weld type, weld location, flaw size and shape, and test temperature and pressure, will be selectively varied to show that a rationale exists for dealing with the varied stress and metallurgical states which normally exist in commercial nuclear reactor vessels. Each vessel will serve as a go, no-go determination of critical flaw size for a specific set of test parameters. Item 4 of the previous issues in this series covers the fabrication details of the first six 6-in.-thick test vessels, which were fabricated from ASTM A-508 Cl 2 forging materials. This report covers the fabrication details of four additional 6-in.-thick intermediate test vessels having shell courses fabricated from ASTM A-533 Gr B Cl 1 plate. The remaining components were made from forgings. Essentially this report is a continuation of ORNL-TM-4351; it describes the manufacturing details of the individual parts and their ultimate assembly into finished vessels. Details concerning chemical composition and mechanical and nondestructive test data are presented

  15. False-Positive Cryptococcal Antigen Test Associated with Use of BBL Port-A-Cul Transport Vials▿

    Science.gov (United States)

    Wilson, Deborah A.; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S.; Procop, Gary W.

    2011-01-01

    A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed. PMID:21159939

  16. Failure Analysis of a Nickel-Plated Electronic Connector Due to Salt-Induced Corrosion (ENGE 2014).

    Science.gov (United States)

    Lee, Na-Ri; Choi, Hyoung-Seuk; Choi, Duck-Kyun

    2015-10-01

    When electronic connectors in mobile devices are miniaturized, the thickness of plating decreases. However, this thin plating is expected to decrease the life of the connector due to problems with corrosion. In this study, salt spray aging tests were performed on miniaturized nickel-plated stainless steel electronic connectors to observe failure mechanisms in realistic environments. The tests were performed three times using a 5% NaCl solution in an atmosphere of 45 °C; each test included several cycles where one cycle was one 24-h period consisting of 8 h of salt spray and 16 h without salt spray. The nickel-plating layers were periodically observed by electron probe X-ray micro-analyzer, wavelength dispersive spectroscopy, and field-emission scanning electron microscopy to analyze and identify the corrosion mechanism. We found that the primary failure mode of the nickel plating is blistering and delamination. The corrosion mechanism is typically a chain reaction of several corrosion mechanisms: pitting corrosion --> stress corrosion cracking --> hydrogen-induced cracking --> blistering and delamination. Finally, we discuss countermeasures to prevent corrosion of the nickel layer based on the corrosion mechanisms identified in this study.

  17. Analytic study of plastic instabilities during tension or compression tests on a metallic plate bi-axially loaded in its plane: symmetric and antisymmetric modes with respect to the median plane

    International Nuclear Information System (INIS)

    Jouve, Dominique

    2012-01-01

    This report is a continuation of the thesis [23], devoted to the onset of necking plastic instabilities during tension tests on metallic plates bi-axially loaded in their plane. We are also interested here in compression tests, and in the development of antisymmetric defects with respect to the median plane of the plate. As in the thesis, we search for the dominant mode, i.e. the most unstable pair of wavelengths (λ1, λ2) in the loading plane. An approximate analytical formulation for the growth rate is proposed, especially for plane-strain tests in the absence of viscous effects, and for static tests in tension in the x1 and x2 loading directions. In that latter case, we retrieve published results [14][15]. For plane-strain tests, we show that infinitely dense networks of shear bands inclined at 45 deg. with respect to the loading direction instantaneously occur when heat softening prevails over work-hardening. (author)

  18. Biomechanical properties of an advanced new carbon/flax/epoxy composite material for bone plate applications.

    Science.gov (United States)

    Bagheri, Zahra S; El Sawi, Ihab; Schemitsch, Emil H; Zdero, Rad; Bougherara, Habiba

    2013-04-01

    This work is part of an ongoing program to develop a new carbon fiber/flax/epoxy (CF/flax/epoxy) hybrid composite material for use as an orthopaedic long bone fracture plate, instead of a metal plate. The purpose of this study was to evaluate the mechanical properties of this new novel composite material. The composite material had a "sandwich structure", in which two thin sheets of CF/epoxy were attached to each outer surface of the flax/epoxy core, which resulted in a unique structure compared to other composite plates for bone plate applications. Mechanical properties were determined using tension, three-point bending, and Rockwell hardness tests. Also, scanning electron microscopy (SEM) was used to characterize the failure mechanism of specimens in tension and three-point bending tests. The results of mechanical tests revealed a considerably high ultimate strength in both tension (399.8MPa) and flexural loading (510.6MPa), with a higher elastic modulus in bending tests (57.4GPa) compared to tension tests (41.7GPa). The composite material experienced brittle catastrophic failure in both tension and bending tests. The SEM images, consistent with brittle failure, showed mostly fiber breakage and fiber pull-out at the fractured surfaces with perfect bonding at carbon fibers and flax plies. Compared to clinically-used orthopaedic metal plates, current CF/flax/epoxy results were closer to human cortical bone, making the material a potential candidate for use in long bone fracture fixation. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal ... Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook ...

  20. Create Your Plate

    Medline Plus

    Full Text Available ... Meals Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with ... Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart-Healthy ...

  1. Create Your Plate

    Medline Plus

    Full Text Available ... of the differences in types of vegetables. When creating your plate at home, remember that half of ... effective for both managing diabetes and losing weight. Creating your plate lets you still choose the foods ...

  2. Create Your Plate

    Medline Plus

    Full Text Available ... Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type 1 Diabetes Get Started Safely Get And ... Plate Create Your Plate is a simple and effective way to manage your blood glucose levels and ...

  3. Create Your Plate

    Medline Plus

    Full Text Available ... foods you want, but changes the portion sizes so you are getting larger portions of non-starchy ... plate. Then on one side, cut it again so you will have three sections on your plate. ...

  4. Elastic stability of thick auxetic plates

    International Nuclear Information System (INIS)

    Lim, Teik-Cheng

    2014-01-01

    Auxetic materials and structures exhibit a negative Poisson’s ratio while thick plates encounter shear deformation, which is not accounted for in classical plate theory. This paper investigates the effect of a negative Poisson’s ratio on thick plates that are subjected to buckling loads, taking into consideration the shear deformation using Mindlin plate theory. Using a highly accurate shear correction factor that allows for the effect of Poisson’s ratio, the elastic stability of circular and square plates are evaluated in terms of dimensionless parameters, namely the Mindlin-to-Kirchhoff critical buckling load ratio and Mindlin critical buckling load factors. Results for thick square plates reveal that both parameters increase as the Poisson’s ratio becomes more negative. In the case of thick circular plates, the Mindlin-to-Kirchhoff critical buckling load ratios and the Mindlin critical buckling load factors increase and decrease, respectively, as the Poisson’s ratio becomes more negative. The results obtained herein show that thick auxetic plates behave as thin conventional plates, and therefore suggest that the classical plate theory can be used to evaluate the elastic stability of thick plates if the Poisson’s ratio of the plate material is sufficiently negative. The results also suggest that materials with highly negative Poisson’s ratios are recommended for square plates, but not circular plates, that are subjected to buckling loads. (paper)

  5. Electron beam hardening type copper plate printing ink

    International Nuclear Information System (INIS)

    Kawamura, Eiji; Inoue, Mitsuo; Kusaki, Satoichiro

    1989-01-01

    Copper plate printing is the printing method of filling ink in the parts of concave printing elements on a type area, and transferring the ink to a base, and it is the feature that the ink in the printing element parts of a print rises. Copper plate prints show profound feeling, in addition, its effect of preventing forgery is high. This method is generally called engraving printing, and is used frequently for printing various bills and artistic prints. The electron beam irradiation apparatus installed in the laboratory of the Printing Bureau, Ministry of Finance, is an experimental machine of area beam type, and is so constructed as to do batch conveyance and web conveyance. As the ink in printing element parts rises, the offset at the delivery part of a printing machine becomes a problem. Electron beam is superior in its transparency, and can dry instantaneously to the inside of opaque ink. At 200 kV of acceleration voltage, the ink of copper plate prints can be hardened by electron beam irradiation. The dilution monomers as the vehicle for ink were tested for their dilution capability and the effect of electron beam hardening. The problem in the utilization of electron beam is the deterioration of papers, and the counter-measures were tested. (K.I.)

  6. Astrometric properties of the Tautenburg Plate Scanner

    Science.gov (United States)

    Brunzendorf, Jens; Meusinger, Helmut

    The Tautenburg Plate Scanner (TPS) is an advanced plate-measuring machine run by the Thüringer Landessternwarte Tautenburg (Karl Schwarzschild Observatory), where the machine is housed. It is capable of digitising photographic plates up to 30 cm × 30 cm in size. In our poster, we reported on tests and preliminary results of its astrometric properties. The essential components of the TPS consist of an x-y table movable between an illumination system and a direct imaging system. A telecentric lens images the light transmitted through the photographic emulsion onto a CCD line of 6000 pixels of 10 µm square size each. All components are mounted on a massive air-bearing table. Scanning is performed in lanes of up to 55 mm width by moving the x-y table in a continuous drift-scan mode perpendicular to the CCD line. The analogue output from the CCD is digitised to 12 bit with a total signal/noise ratio of 1000 : 1, corresponding to a photographic density range of three. The pixel map is produced as a series of optionally overlapping lane scans. The pixel data are stored onto CD-ROM or DAT. A Tautenburg Schmidt plate 24 cm × 24 cm in size is digitised within 2.5 hours resulting in 1.3 GB of data. Subsequent high-level data processing is performed off-line on other computers. During the scanning process, the geometry of the optical components is kept fixed. The optimal focussing of the optics is performed prior to the scan. Due to the telecentric lens refocussing is not required. Therefore, the main source of astrometric errors (beside the emulsion itself) are mechanical imperfections in the drive system, which have to be divided into random and systematic ones. The r.m.s. repeatability over the whole plate as measured by repeated scans of the same plate is about 0.5 µm for each axis. The mean plate-to-plate accuracy of the object positions on two plates with the same epoch and the same plate centre has been determined to be about 1 µm. This accuracy is comparable to

  7. Evaluation of participants' perception and taste thresholds with a zirconia palatal plate.

    Science.gov (United States)

    Wada, Takeshi; Takano, Tomofumi; Tasaka, Akinori; Ueda, Takayuki; Sakurai, Kaoru

    2016-10-01

    Zirconia and cobalt-chromium can withstand a similar degree of loading. Therefore, using a zirconia base for removable dentures could allow the thickness of the palatal area to be reduced similarly to metal base dentures. We hypothesized that zirconia palatal plate for removable dentures provides a high level of participants' perception without influencing taste thresholds. The purpose of this study was to evaluate the participants' perception and taste thresholds of zirconia palatal plate. Palatal plates fabricated using acrylic resin, zirconia, and cobalt-chromium alloy were inserted into healthy individuals. Taste thresholds were investigated using the whole-mouth gustatory test, and participants' perception was evaluated using the 100-mm visual analog scale to assess the ease of pronunciation, ease of swallowing, sensation of temperature, metallic taste, sensation of foreign body, subjective sensory about weight, adhesiveness of chewing gum, and general satisfaction. For the taste thresholds, no significant differences were noted in sweet, salty, sour, bitter, or umami tastes among participants wearing no plate, or the resin, zirconia, and metal plates. Speech was easier and foreign body sensation was lower with the zirconia plate than with the resin plate. Evaluation of the adhesiveness of chewing gum showed that chewing gum does not readily adhere to the zirconia plate in comparison with the metal plate. The comprehensive participants' perception of the zirconia plate was evaluated as being superior to the resin plate. A zirconia palatal plate provides a high level of participants' perception without influencing taste thresholds. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  8. Off state breakdown behavior of AlGaAs / InGaAs field plate pHEMTs

    International Nuclear Information System (INIS)

    Palma, John; Mil'shtein, Samson

    2014-01-01

    Off-state breakdown voltage, V br , is an important parameter determining the maximum power output of microwave Field Effect Transistors (FETs). In recent years, the use of field plates has been widely adopted to significantly increase V br . This important technological development has extended FET technologies into new areas requiring these higher voltages and power levels. Keeping with this goal, field plates were added to an existing AlGaAs / InGaAs pseudomorphic High Electron Mobility Transistor (pHEMT) process with the aim of determining the off-state breakdown mechanism and the dependency of V br on the field plate design. To find the mechanism responsible for breakdown, temperature dependent off-state breakdown measurements were conducted. It was found that at low current levels, the temperature dependence indicates thermionic field emission at the Schottky gate and at higher current levels, impact ionization is indicated. The combined results imply that impact ionization is ultimately the mechanism that is responsible for the breakdown in the tested transistors, but that it is preceded by thermionic field emission from the gate. To test the dependence of V br upon the field plate design, the field plate length and the etch depth through the highly-doped cap layer under the field plate were varied. Also, non-field plate devices were tested along side field plate transistors. It was found that the length of the etched region under the field plate is the dominant factor in determining the off-state breakdown of the more deeply etched devices. For less deeply etched devices, the length of the field plate is more influential. The influence of surface states between the highly doped cap layer and the passivation layer along the recess are believed to have a significant influence in the case of the more deeply etched examples. It is believed that these traps spread the electric field, thus raising the breakdown voltage. Three terminal breakdown voltages

  9. Flow induced deformation and collapse of a thin rectangular plate with application to the Engineering Test Reactor nuclear fuel elements

    International Nuclear Information System (INIS)

    Davis, C.D.

    1981-01-01

    This work examines a single flat fuel plate bounded by two channels and determines static plate deflections, resultant forces and bending stresses due to pressure differential and hydrodynamic loadings. The classical then reactangular plate equations are used to model the fuel plate. These equations contain as an input the hydrodynamic loading function for modeling the fluid-structural interaction. Two models of the channel flow are developed. One assumes the accelerating potential core flow is laminar with developing two-dimensional laminar boundary layers being formed on the channel walls. The Schlichting entry length solution for developing laminar flow is found to be valid the entire length of the channel. The second model assumes the core flow is fully-developed turbulent the entire length of the channel. Hydrodynamic loading functions are developed for both flow models containing parameters for fluid density, fluid velocity, Reynolds number and channel and plate dimensions. Hence the effects of each parameter can be examined independently. A criterion is developed for predicting ETR fuel plate collapse at high channel flow velocities, 1067 cm/s (420 in/sec) (R/sub e/ = 60,000). The criterion predicts that in order to prevent ETR plate collapse the inlet velocities between channels must not differ by more than 2%

  10. Neutron imaging plates

    International Nuclear Information System (INIS)

    Niimura, Nobuo

    1995-01-01

    Imaging plates have been used in the field of medical diagnosis since long ago, but their usefulness was verified as the two-dimensional detector for analyzing the X-ray crystalline structure of high bio molecules like protein, and they have contributed to the remarkable progress in this field. The great contribution is due to the excellent features, such as the detection efficiency of about 100%, the positional resolution smaller than 0.2 mm, the dynamic range of five digits, and the area of several hundreds mm square. The neutron imaging plates have not yet obtained the sufficient results. It was planned to construct the neutron diffractometer for biological matters, and to put imaging plate neutron detectors (IP-ND) to practical use as the detector. The research on the development of IP-NDs was carried out, and the IPp-NDs having the performance comparable with that for X-ray were able to be produced. Imaging plates are the integral type two-dimensional radiation detector using photostimulated luminescence matters, and their principle is explained. As to neutron imaging plates, the converter, neutron detection efficiency and the flight of secondary particles in photo-stimulated luminescence matters are described. As for the present state of development of neutron imaging plates, the IP-NDs made for trial, the dynamic range, the positional resolution, the detection efficiency and the kinds of converters, and the application of IP-NDs are reported. (K.I.)

  11. Preliminary experiments using light-initiated high explosive for driving thin flyer plates

    International Nuclear Information System (INIS)

    Benham, R.A.

    1980-02-01

    Light-initiated high explosive, silver acelytide - silver-nitrate (SASN), has been used to produce simulated x ray blow-off impulse loading on reentry vehicles to study the system structural response. SASN can be used to accelerate thin flyer plates to high terminal velocities which, in turn, can deliver a pressure pulse that can be tailored to the target material. This process is important for impulse tests where both structural and material response is desired. The theories used to calculate the dynamic state of the flyer plate prior to impact are summarized. Data from several experiments are presented which indicate that thin flyer plates can be properly accelerated and that there are predictive techniques available which are adequate to calculate the motion of the flyer plate. Recommendations are made for future study that must be undertaken to make the SASN flyer plate technique usable

  12. Towards stacked zone plates

    International Nuclear Information System (INIS)

    Werner, S; Rehbein, S; Guttman, P; Heim, S; Schneider, G

    2009-01-01

    Fresnel zone plates are the key optical elements for soft and hard x-ray microscopy. For short exposure times and minimum radiation load of the specimen the diffraction efficiency of the zone plate objectives has to be maximized. As the efficiency strongly depends on the height of the diffracting zone structures the achievable aspect ratio of the nanostructures determines these limits. To reach aspect ratios ≥ 20:1 for high efficient optics we propose to superimpose zone plates on top of each other. With this multiplication approach the final aspect ratio is only limited by the number of stacked zone plate layers. For the stack process several nanostructuring process steps have to be developed and/or improved. Our results show for the first time two layers of zone plates stacked on top of each other.

  13. Micro-channel plate photon detector studies for the TORCH detector

    Energy Technology Data Exchange (ETDEWEB)

    Castillo García, L., E-mail: lucia.castillo.garcia@cern.ch [CERN, PH Department, CH-1211, Geneva 23 (Switzerland); Laboratory for High Energy Physics, Ecole Polytechnique Fédérale de Lausanne, CH-1015 Lausanne (Switzerland); Brook, N.; Cowie, E.N.; Cussans, D. [H.H. Wills Physics Laboratory, University of Bristol, Bristol BS8 1TL (United Kingdom); Forty, R.; Frei, C. [CERN, PH Department, CH-1211, Geneva 23 (Switzerland); Gao, R. [Department of Physics, University of Oxford, Oxford OXI 3RH (United Kingdom); Gys, T. [CERN, PH Department, CH-1211, Geneva 23 (Switzerland); Harnew, N. [Department of Physics, University of Oxford, Oxford OXI 3RH (United Kingdom); Piedigrossi, D. [CERN, PH Department, CH-1211, Geneva 23 (Switzerland); Van Dijk, M. [H.H. Wills Physics Laboratory, University of Bristol, Bristol BS8 1TL (United Kingdom)

    2015-07-01

    The Time Of internally Reflected Cherenkov light (TORCH) detector is under development. Charged particle tracks passing through a 1 cm plate of quartz will generate the Cherenkov photons, and their arrival will be timed by an array of micro-channel plate photon detectors. As part of the TORCH R&D studies, commercial and custom-made micro-channel plate detectors are being characterized. The final photon detectors for this application are being produced in a three-phase program in collaboration with industry. Custom-made single-channel devices with extended lifetime have been manufactured and their performance is being systematically investigated in the laboratory. Optical studies for the preparation of beam and laboratory tests of a TORCH prototype are also underway.

  14. Heat transfer studies on spiral plate heat exchanger

    Directory of Open Access Journals (Sweden)

    Rajavel Rangasamy

    2008-01-01

    Full Text Available In this paper, the heat transfer coefficients in a spiral plate heat exchanger are investigated. The test section consists of a plate of width 0.3150 m, thickness 0.001 m and mean hydraulic diameter of 0.01 m. The mass flow rate of hot water (hot fluid is varying from 0.5 to 0.8 kg/s and the mass flow rate of cold water (cold fluid varies from 0.4 to 0.7 kg/s. Experiments have been conducted by varying the mass flow rate, temperature, and pressure of cold fluid, keeping the mass flow rate of hot fluid constant. The effects of relevant parameters on spiral plate heat exchanger are investigated. The data obtained from the experimental study are compared with the theoretical data. Besides, a new correlation for the Nusselt number which can be used for practical applications is proposed.

  15. Ultrasonic diagnosis of spot welding in thin plates

    International Nuclear Information System (INIS)

    Kim, No You; Hong, Min Sung

    2005-01-01

    Spot welding widely used in automotive and aerospace industries has made it possible to produce more precise and smaller electric part by robotization and systemization of welding process. The quality of welding depends upon the size of nugget between the overlapped steel plates. Recently, the thickness of the steel plates becomes much thinner and hence, it introduces the smaller size of nugget. Therefore, it is necessary to develop the criterion to evaluate the quality of weld in order to obtain the optimal welding conditions for the better performance. In this paper, a thin steel plates, 0.1 mm through 0.3 mm thickness, have been spot-welded at different welding conditions and the nugget sizes are examined by defocused scanning microscopy. The relationships between nugget sizes and weldability have been investigated experimentally. The result of ultrasonic technique shows the good agreement with that of the tensile test.

  16. Choosing a proper working length can improve the lifespan of locked plates. A biomechanical study.

    Science.gov (United States)

    Hoffmeier, Konrad L; Hofmann, Gunther O; Mückley, Thomas

    2011-05-01

    It is hypothesized that the working length influences the implants fatigue behavior. However, few studies addressing this issue came to contrary results. Therefore, we tested systematically the influence of working length and implant material on the plate's endurance. We used an artificial model providing the substantial angle and length conditions of a human femur. A fracture gap of 10mm was bridged with identical shaped plate implants made of stainless steel and grade-2 titanium. The fatigue strength was tested for a short, medium and long working length. Aiming at an implant failure within 80,000 loading cycles the upper load threshold was set to 265N for the titanium plates and to 420N for the steel plates. The lower load threshold was -20N for both plates. For the steel plates there was no correlation between fatigue strength and working length. The construct stiffness did not differ at short and medium working length and was reduced by 10% (P=0.047) at long working length. For the titanium plates the fatigue strength tends to increase with the working length but this correlation was not significant (τ=0.417, P=0.051). Further there was a negative correlation between working length and construct stiffness (τ=0.552; P=0.01). The working length has no appreciable effect on the endurance of the steel plates. Compared to the grade 2-titanium plates the stainless steel plates sustain a larger amount of cyclic load. However, for the titanium plates a larger working length tends to improve the endurance. Copyright © 2010 Elsevier Ltd. All rights reserved.

  17. Improving greater trochanteric reattachment with a novel cable plate system.

    Science.gov (United States)

    Baril, Yannick; Bourgeois, Yan; Brailovski, Vladimir; Duke, Kajsa; Laflamme, G Yves; Petit, Yvan

    2013-03-01

    Cable-grip systems are commonly used for greater trochanteric reattachment because they have provided the best fixation performance to date, even though they have a rather high complication rate. A novel reattachment system is proposed with the aim of improving fixation stability. It consists of a Y-shaped fixation plate combined with locking screws and superelastic cables to reduce cable loosening and limit greater trochanter movement. The novel system is compared with a commercially available reattachment system in terms of greater trochanter movement and cable tensions under different greater trochanteric abductor application angles. A factorial design of experiments was used including four independent variables: plate system, cable type, abductor application angle, and femur model. The test procedure included 50 cycles of simultaneous application of an abductor force on the greater trochanter and a hip force on the femoral head. The novel plate reduces the movements of a greater trochanter fragment within a single loading cycle up to 26%. Permanent degradation of the fixation (accumulated movement based on 50-cycle testing) is reduced up to 46%. The use of superelastic cables reduces tension loosening up to 24%. However this last improvement did not result in a significant reduction of the grater trochanter movement. The novel plate and cables present advantages over the commercially available greater trochanter reattachment system. The plate reduces movements generated by the hip abductor. The superelastic cables reduce cable loosening during cycling. Both of these positive effects could decrease the risks related to grater trochanter non-union. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  18. LOWLID FORMATION AND PLATE TECTONICS ON EXOPLANETS

    Science.gov (United States)

    Stamenkovic, V.; Noack, L.; Breuer, D.

    2009-12-01

    The last years of astronomical observation have opened the doors to a universe filled with extrasolar planets. Detection techniques still only offer the possibility to detect mainly Super-Earths above five Earth masses. But detection techniques do steadily improve and are offering the possibility to detect even smaller planets. The observations show that planets seem to exist in many possible sizes just as the planets and moons of our own solar system do. It is only a natural question to ask if planetary mass has an influence on some key habitability factors such as on plate tectonics, allowing us to test which exoplanets might be more likely habitable than others, and allowing us to understand if plate tectonics on Earth is a stable or a critical, instable process that could easily be perturbed. Here we present results derived from 1D parameterized thermal evolution and 2D/3D computer models, showing how planetary mass influences the propensity of plate tectonics for planets with masses ranging from 0.1 to 10 Earth masses. Lately [2, 3] studied the effect of planetary mass on the ability to break plates and hence initiate plate tectonics - but both derived results contradictory to the other. We think that one of the reasons why both studies [2, 3] are not acceptable in their current form is partly due to an oversimplification. Both treated viscosity only temperature-dependent but neglected the effect pressure has on enlarging the viscosity in the deep mantle. More massive planets have therefore a stronger pressure-viscosity-coupling making convection at high pressures sluggish or even impossible. For planets larger than two Earth masses we observe that a conductive lid (termed low-lid) forms above the core-mantle boundary and thus reduces the effective convective part of the mantle when including a pressure-dependent term into the viscosity laws as shown in [1]. Moreover [2, 3] use time independent steady state models neglecting the fact that plate tectonics is a

  19. Anisotropic elastic plates

    CERN Document Server

    Hwu, Chyanbin

    2010-01-01

    As structural elements, anisotropic elastic plates find wide applications in modern technology. The plates here are considered to be subjected to not only in plane load but also transverse load. In other words, both plane and plate bending problems as well as the stretching-bending coupling problems are all explained in this book. In addition to the introduction of the theory of anisotropic elasticity, several important subjects have are discussed in this book such as interfaces, cracks, holes, inclusions, contact problems, piezoelectric materials, thermoelastic problems and boundary element a

  20. Mechanical properties of F82H plates with different thicknesses

    Energy Technology Data Exchange (ETDEWEB)

    Sakasegawa, Hideo, E-mail: sakasegawa.hideo@jaea.go.jp; Tanigawa, Hiroyasu

    2016-11-01

    Highlights: • Mass effect, homogeneity, and anisotropy in mechanical properties were studied. • Thickness dependence of tensile property was not observed. • Thickness dependence of Charpy impact property was observed. • Appropriate mechanical properties were obtained using an electric furnace. - Abstract: Fusion DEMO reactor requires over 11,000 tons of reduced activation ferritic/martensitic steel and it is indispensable to develop the manufacturing technology for producing large-scale components of DEMO blanket with appropriate mechanical properties. This is because mechanical properties are generally degraded with increasing production volume. In this work, we focused mechanical properties of F82H–BA12 heat which was melted in a 20 tons electric arc furnace. Plates with difference thicknesses from 18 to 100 mm{sup t} were made from its ingot through forging and hot-rolling followed by heat treatments. Tensile and Charpy impact tests were then performed on plates focusing on their homogeneity and anisotropy. From the result, their homogeneity and anisotropy were not significant. No obvious differences were observed in tensile properties between the plates with different thicknesses. However, Charpy impact property changed with increasing plate thickness, i.e. the ductile brittle transition temperature of a 100 mm{sup t} thick plate was higher than that of the other thinner plates.