  1. A remote reactor monitoring with plastic scintillation detector

    CERN Document Server

    Georgadze, A Sh; Ponkratenko, O A; Litvinov, D A

    2016-01-01

    Conceiving the possibility of using plastic scintillator bars as robust detectors for antineutrino detection for the remote reactor monitoring and nuclear safeguard application we study expected basic performance by Monte Carlo simulation. We present preliminary results for a 1 m3 highly segmented detector made of 100 rectangular scintillation bars forming an array which is sandwiched at both sides by the continuous light guides enabling light sharing between all photo detectors. Light detection efficiency is calculated for several light collection configurations, considering different scintillation block geometries and number of photo-detectors. The photo-detectors signals are forming the specific hit pattern, which is characterizing the impinging particle. The statistical analysis of hit patterns allows effectively select antineutrino events and rejects backgrounds. To evaluate detector sensitivity to fuel isotopic composition evolution during fuel burning cycle we have calculated antineutrino spectra. The ...

  2. Dosimetry in clinical static magnetic fields using plastic scintillation detectors

    DEFF Research Database (Denmark)

    Stefanowicz, S.; Latzel, H.; Lindvold, Lars René

    2013-01-01

    , however, not clear yet how dosimetry will be conducted as standard methods and might not be easily transferred to systems with clinical magnetic fields. For dosimetry in MRI accelerators, we have tested plastic scintillation detectors (PSD) coupled to optical fibers. They are suitable for real-time and in......-vivo dosimetry in radiation treatments and diagnostics and could be, being all-optical, promising candidates for this application. To study the basic feasibility of using PSDs with organic scintillators in magnetic fields, we measured the response of these dosimeters in presence of magnetic fields up to 1 T...

  3. Fast-Neutron Survey With Compact Plastic Scintillation Detectors.

    Science.gov (United States)

    Preston, Rhys M; Tickner, James R

    2017-07-01

    With the rise of the Silicon Photomultiplier (SiPM), it is now practical to build compact scintillation detectors well suited to portable use. A prototype survey meter for fast-neutrons and gamma-rays, based around an EJ-299-34 plastic scintillator with SiPM readout, has been developed and tested. A custom digital pulse processor was used to perform pulse shape discrimination on-the-fly. Ambient dose equivalent H*(10) was calculated by means of two energy-dependent 'G-functions'. The sensitivity was calculated to be between 0.10 and 0.22 cps/(µSv/hr) for fast-neutrons with energies above 2.5 MeV. The prototype was used to survey various laboratory radiation fields, with the readings compared with commercial survey meters. The high sensitivity and lightweight nature of this detector makes it promising for rapid survey of the mixed neutron/gamma-ray fields encountered in industry and homeland security. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Scintillation Particle Detectors Based on Plastic Optical Fibres and Microfluidics

    CERN Document Server

    Mapelli, Alessandro; Renaud, Philippe

    2011-01-01

    This thesis presents the design, development, and experimental validation of two types of scintillation particle detectors with high spatial resolution. The first one is based on the well established scintillating fibre technology. It will complement the ATLAS (A Toroidal Large ApparatuS) detector at the CERN Large Hadron Collider (LHC). The second detector consists in a microfabricated device used to demonstrate the principle of operation of a novel type of scintillation detector based on microfluidics. The first part of the thesis presents the work performed on a scintillating fibre tracking system for the ATLAS experiment. It will measure the trajectory of protons elastically scattered at very small angles to determine the absolute luminosity of the CERN LHC collider at the ATLAS interaction point. The luminosity of an accelerator characterizes its performance. It is a process-independent parameter that is completely determined by the properties of the colliding beams and it relates the cross section of a ...

  5. A mathematical formalism for hyperspectral, multipoint plastic scintillation detectors.

    Science.gov (United States)

    Archambault, Louis; Therriault-Proulx, François; Beddar, Sam; Beaulieu, Luc

    2012-11-07

    The aim of this paper is to generalize and extend the mathematical formalism used with plastic scintillation detectors (PSDs). By doing so, we show the feasibility of multi-point PSD. The new formalism is based on the sole hypothesis that a PSD optical signal is a linear superposition of spectra. Two calibration scenarios were developed. Both involve solving a linear equation of the form Y = XB, but the process and input data depend on the information available on the detector system. Simulations were carried out to validate both scenarios and demonstrate the advantages of the new formalism. In this paper, we prove the following results. (1) Multi-point PSDs are feasible. Simulations have shown that six different spectra could be resolved accurately even in the presence of up to 10% Gaussian noise. (2) The new formalism leads to more precise PSD measurements. (3) By using the condition number of the measurement matrix, the ideal sets of calibration measurements can be identified. (4) By using principal component analysis it was possible to identify the best set of wavelength filters. We have shown through numerical simulations that multi-point detectors are feasible. This has potential for applications such as in vivo dose verification. Furthermore, our new formalism can be used to improve the robustness and ease of use of PSDs.

  6. The plastic scintillator detector calibration circuit for DAMPE

    Science.gov (United States)

    Yang, Haibo; Kong, Jie; Zhao, Hongyun; Su, Hong

    2016-07-01

    The Dark Matter Particle Explorer (DAMPE) is being constructed as a scientific satellite to observe high energy cosmic rays in space. Plastic scintillator detector array (PSD), developed by Institute of Modern Physics, Chinese Academy of Sciences (IMPCAS), is one of the most important parts in the payload of DAMPE which is mainly used for the study of dark matter. As an anti-coincidence detector, and a charged-particle identification detector, the PSD has a total of 360 electronic readout channels, which are distributed at four sides of PSD using four identical front end electronics (FEE). Each FEE reads out 90 charge signals output by the detector. A special calibration circuit is designed in FEE. FPGA is used for on-line control, enabling the calibration circuit to generate the pulse signal with known charge. The generated signal is then sent to the FEE for calibration and self-test. This circuit mainly consists of DAC, operation amplifier, analog switch, capacitance and resistance. By using controllable step pulse, the charge can be coupled to the charge measuring chip using the small capacitance. In order to fulfill the system's objective of large dynamic range, the FEE is required to have good linearity. Thus, the charge-controllable signal is needed to do sweep test on all channels in order to obtain the non-linear parameters for off-line correction. On the other hand, the FEE will run on the satellite for three years. The changes of the operational environment and the aging of devices will lead to parameter variation of the FEE, highlighting the need for regular calibration. The calibration signal generation circuit also has a compact structure and the ability to work normally, with the PSD system's voltage resolution being higher than 0.6%.

  7. Development of Plastic Scintillator Detector Array Based on SPMT

    Institute of Scientific and Technical Information of China (English)

    SU; Dan; ZHANG; Guo-guang; ZHAO; Xiao; FENG; Shu-qiang; ZHANG; Shuai

    2015-01-01

    Silicon photoelectric multiplier tuber(SPMT)is made of silicon chip,which can collect weak optical signal(Fig.1).When visible light irradiates SPMT,SPMT can change optical signal to electrical signal.The electrical signal size can be obtained through detecting optical signal size.When putting plastic scintillator before

  8. Radiation hardness of plastic scintillators for the Tile Calorimeter of the ATLAS detector

    CERN Document Server

    Jivan, Harshna; The ATLAS collaboration

    2014-01-01

    The Tile Calorimeter of the ATLAS detector, is a hadronic calorimeter responsible for detecting hadrons as well as accommodating for the missing transverse energy that result from the p-p collisions within the LHC. Plastic scintillators form an integral component of this calorimeter due to their ability to undergo prompt fluorescence when exposed to ionising particles. The scintillators employed are specifically chosen for their properties of high optical transmission and fast rise and decay time which enables efficient data capture since fast signal pulses can be generated. The main draw-back of plastic scintillators however is their susceptibility to radiation damage. The damage caused by radiation exposure reduces the scintillation light yield and introduces an error into the time-of flight data acquired. During Run 1 of the LHC data taking period, plastic scintillators employed within the GAP region between the Tile Calorimeter’s central and extended barrels sustained a significant amount of damage. Wit...

  9. Measurements of the electron dose distribution near inhomogeneities using a plastic scintillation detector

    Energy Technology Data Exchange (ETDEWEB)

    Wells, C.M.M.; Mackie, T.R.; Podgorsak, M.B.; Holmes, M.A.; Papanikolaou, N.; Reckwerdt, P.J. [Univ. of Wisconsin, Madison, WI (United States); Cygler, J. [Ottawa Regional Cancer Center, Ontario (Canada); Rogers, D.W.O.; Bielajew, A.F. [National Research Council of Canada, Ottawa, Ontario (Canada); Schmidt, D.G. [Radiation Measurements, Inc., Middleton, WI (United States)] [and others

    1994-07-30

    Accurate measurement of the electron dose distribution near an inhomogeneity is difficult with traditional dosimeters which themselves perturb the electron field. The authors tested the performance of a new high resolution, water-equivalent plastic scintillation detector which has ideal properties for this application. A plastic scintillation detector with a 1 mm diameter, 3 mm long cylindrical sensitive volume was used to measure the dose distributions behind standard benchmark inhomogeneities in water phantoms. The plastic scintillator material is more water equivalent than polystyrene in terms of its mass collision stopping power and mass scattering power. Measurements were performed for beams of electrons having initial energies of 6 and 18 MeV at depths from 0.2-4.2 cm behind the inhomogeneities. The detector reveals hot and cold spots behind heterogeneities at resolutions equivalent to typical film digitizer spot sizes. Plots of the dose distributions behind air, aluminum, lead, and formulations for cortical and inner bone-equivalent materials are presented. The plastic scintillation detector is suited for measuring the electron dose distribution near an inhomogeneity. 14 refs., 9 figs.

  10. A systematic characterization of the low-energy photon response of plastic scintillation detectors.

    Science.gov (United States)

    Boivin, Jonathan; Beddar, Sam; Bonde, Chris; Schmidt, Daniel; Culberson, Wesley; Guillemette, Maxime; Beaulieu, Luc

    2016-08-01

    To characterize the low energy behavior of scintillating materials used in plastic scintillation detectors (PSDs), 3 PSDs were developed using polystyrene-based scintillating materials emitting in different wavelengths. These detectors were exposed to National Institute of Standards and Technology (NIST)-matched low-energy beams ranging from 20 kVp to 250 kVp, and to (137)Cs and (60)Co beams. The dose in polystyrene was compared to the dose in air measured by NIST-calibrated ionization chambers at the same location. Analysis of every beam quality spectrum was used to extract the beam parameters and the effective mass energy-absorption coefficient. Monte Carlo simulations were also performed to calculate the energy absorbed in the scintillators' volume. The scintillators' expected response was then compared to the experimental measurements and an energy-dependent correction factor was identified to account for low-energy quenching in the scintillators. The empirical Birks model was then compared to these values to verify its validity for low-energy electrons. The clear optical fiber response was below 0.2% of the scintillator's light for x-ray beams, indicating that a negligible amount of fluorescence contamination was produced. However, for higher-energy beams ((137)Cs and (60)Co), the scintillators' response was corrected for the Cerenkov stem effect. The scintillators' response increased by a factor of approximately 4 from a 20 kVp to a (60)Co beam. The decrease in sensitivity from ionization quenching reached a local minimum of about [Formula: see text] between 40 keV and 60 keV x-ray beam mean energy, but dropped by 20% for very low-energy (13 keV) beams. The Birks model may be used to fit the experimental data, but it must take into account the energy dependence of the kB quenching parameter. A detailed comprehension of intrinsic scintillator response is essential for proper calibration of PSD dosimeters for radiology.

  11. Image quality evaluation of linear plastic scintillating fiber array detector for X-ray imaging

    Institute of Scientific and Technical Information of China (English)

    Mohammad Mehdi NASSERI; MA Qing-Li; YIN Ze-Jie

    2004-01-01

    It is important to assess image quality, in order to ensure that the imaging system is performing optimally and also identify the weak points in an imaging system. Three parameters mostly leading to image degradation are contrast, spatial resolution and noise. There is always a trade-off between spatial resolution and signal to noise ratio,but in scintillating fiber array detectors spatial resolution is not as important as signal to noise ratio, so we paid more attention to contrast and SNR of the system. By using GEANT4 Monte Carlo detector simulation toolkit, some effective parameters of the linear plastic scintillating fiber (PSF) array as an imaging detector were investigated. Finally we show that it is possible to use this kind of detector to take CT and DR (Digital Radiography) image under certain conditions.

  12. Dosimetry in clinical static magnetic fields using plastic scintillation detectors

    DEFF Research Database (Denmark)

    Stefanowicz, S.; Latzel, H.; Lindvold, Lars René

    2013-01-01

    . In conclusion, we found some deviations up to 7% of the supposed signal. Although the scintillators are of much denser material, we measured the same behavior in signal as in (Meijsing et al., 2009) for a Farmer ionization chamber or as in (Raaijmakers et al., 2007) for films described which indicates radiation...

  13. Coincidence system for standardization of radionuclides using a 4pi plastic scintillator detector.

    Science.gov (United States)

    Baccarelli, Aída M; Dias, Mauro S; Koskinas, Marina F

    2003-02-01

    A coincidence system using a plastic scintillator detector in 4pi geometry has been developed and applied for the standardization of radionuclides. The scintillator shape and dimensions have been optimized for maximum charge particle detection efficiency, while keeping background low and a nearly constant gamma-ray efficiency for different points from the radioactive source. The gamma-ray events were measured with a NaI(Tl) scintillation counter. The electronic system for processing pulses consisted of logic gates and delay modules feeding a time-to-amplitude converter with output to a multichannel analyzer. The alpha detection efficiency measured with 241Am was around 95% and the beta detection efficiency for 60Co was around 67%. Activity measurements of 241Am and 60Co were performed and the results showed good agreement when compared with a conventional coincidence system employing a 4pi proportional counter.

  14. Coincidence system for standardization of radionuclides using a 4 pi plastic scintillator detector

    CERN Document Server

    Baccarelli, A M; Koskinas, M F

    2003-01-01

    A coincidence system using a plastic scintillator detector in 4 pi geometry has been developed and applied for the standardization of radionuclides. The scintillator shape and dimensions have been optimized for maximum charge particle detection efficiency, while keeping background low and a nearly constant gamma-ray efficiency for different points from the radioactive source. The gamma-ray events were measured with a NaI(Tl) scintillation counter. The electronic system for processing pulses consisted of logic gates and delay modules feeding a time-to-amplitude converter with output to a multichannel analyzer. The alpha detection efficiency measured with sup 2 sup 4 sup 1 Am was around 95% and the beta detection efficiency for sup 6 sup 0 Co was around 67%. Activity measurements of sup 2 sup 4 sup 1 Am and sup 6 sup 0 Co were performed and the results showed good agreement when compared with a conventional coincidence system employing a 4 pi proportional counter.

  15. A large dynamic range readout design for the plastic scintillator detector of DAMPE

    Science.gov (United States)

    Zhou, Yong; Sun, Zhiyu; Yu, Yuhong; Zhang, Yongjie; Fang, Fang; Chen, Junling; Hu, Bitao

    2016-08-01

    A large dynamic range is required by the Plastic Scintillator Detector (PSD) of DArk Matter Particle Explorer (DAMPE) to detect particles from electron to heavy ions with Z ≤ 20. To expand the dynamic range, the readout design based on the double-dynodes signal extraction from the photomultiplier tube has been proposed and adopted by PSD. To verify this design, a prototype detector module has been constructed and tested with cosmic ray and relativistic ion beam. The results match with the estimation and the readout unit could easily cover the required dynamic range of about 4 orders of magnitude.

  16. Plastic scintillation detectors for precision time-of-flight measurements of relativistic heavy ions

    CERN Document Server

    Lin, Wen-Jian; Sun, Bao-Hua; He, Liu-Chun; Lin, Wei-Ping; Liu, Chuan-Ye; Tanihata, Isao; Terashima, Satoru; Tian, Yi; Wang, Feng; Wang, Meng; Zhang, Guang-Xin; Zhang, Xue-Heng; Zhu, Li-Hua; Duan, Li-Min; Hu, Rong-Jiang; Liu, Zhong; Lu, Chen-Gui; Ren, Pei-Pei; Sheng, Li-Na; Sun, Zhi-Yu; Wang, Shi-Tao; Wang, Tao-Feng; Xu, Zhi-Guo; Yan, Duo; Yue, Ke; Zheng, Yong

    2016-01-01

    Plastic scintillation detectors for Time-of-Flight (TOF) measurements are almost essential for event-by-event identification of relativistic rare isotopes. In this work, a pair of plastic scintillation detectors of 50 $\\times$ 50 $\\times$ 3$^{t}$ mm$^3$ and 80 $\\times$ 100 $\\times$ 3$^{t}$ mm$^3$ have been set up at the external target facility (ETF), Institute of Modern Physics. Their time, energy and position responses are measured with $^{18}$O primary beam at 400 MeV/nucleon. After the off-line walk-effect and position corrections, the time resolution of the two detectors are determined to be 27 ps ($\\sigma$) and 36 ps ($\\sigma$), respectively. Both detectors have nearly the same energy resolution of 3$\\%$ ($\\sigma$) and position resolution of 2 mm ($\\sigma$). The detectors have been used successfully in nuclear reaction cross section measurements, and will be be employed for upgrading RIBLL2 beam line at IMP as well as for the high energy branch at HIAF.

  17. Extensive studies of MRS APDs for plastic scintillator muon veto detectors of cryogenic experiments

    Energy Technology Data Exchange (ETDEWEB)

    Falkenstein, R., E-mail: falkenst@pit.physik.uni-tuebingen.de [Kepler Center for Astro and Particle Physics, University of Tuebingen, Auf der Morgenstelle 14, 72076 Tuebingen (Germany); Bezrukov, L.B. [Institute for Nuclear Research of RAS, Moscow (Russian Federation); Freund, K. [Kepler Center for Astro and Particle Physics, University of Tuebingen, Auf der Morgenstelle 14, 72076 Tuebingen (Germany); Golovin, A.V.; Golovin, V.M. [Centre for Perspective Technology and Apparatus, Moscow (Russian Federation); Grabmayr, P.; Jochum, J. [Kepler Center for Astro and Particle Physics, University of Tuebingen, Auf der Morgenstelle 14, 72076 Tuebingen (Germany); Lubsandorzhiev, B.K. [Kepler Center for Astro and Particle Physics, University of Tuebingen, Auf der Morgenstelle 14, 72076 Tuebingen (Germany); Institute for Nuclear Research of RAS, Moscow (Russian Federation); Lubsandorzhiev, N.B.; Poleshuk, R.V. [Institute for Nuclear Research of RAS, Moscow (Russian Federation); Polyansky, I.N. [Centre for Perspective Technology and Apparatus, Moscow (Russian Federation); Ritter, F.; Sailer, C. [Kepler Center for Astro and Particle Physics, University of Tuebingen, Auf der Morgenstelle 14, 72076 Tuebingen (Germany); Shaibonov, B.A.M. [Institute for Nuclear Research of RAS, Moscow (Russian Federation)

    2012-12-11

    Low background experiments need active muon veto detectors to shield them from cosmic muons. Plastic scintillator panels with WLS fiber and multi-pixel Geiger-mode avalanche photodiodes readout are widely used in such experiments due to their compactness and robustness. In this paper, results from the study of the basic MRS APD parameters, such as breakdown voltages, quenching resistors, internal gain and dark count rates are presented, as well as temperature dependencies of some of these parameters. In a small fraction of the MRS APDs, some strange dips in the I-V curves just preceding the breakdown voltage point have been observed.

  18. Extensive studies of MRS APDs for plastic scintillator muon veto detectors of cryogenic experiments

    Science.gov (United States)

    Falkenstein, R.; Bezrukov, L. B.; Freund, K.; Golovin, A. V.; Golovin, V. M.; Grabmayr, P.; Jochum, J.; Lubsandorzhiev, B. K.; Lubsandorzhiev, N. B.; Poleshuk, R. V.; Polyansky, I. N.; Ritter, F.; Sailer, C.; Shaibonov, B. A. M.

    2012-12-01

    Low background experiments need active muon veto detectors to shield them from cosmic muons. Plastic scintillator panels with WLS fiber and multi-pixel Geiger-mode avalanche photodiodes readout are widely used in such experiments due to their compactness and robustness. In this paper, results from the study of the basic MRS APD parameters, such as breakdown voltages, quenching resistors, internal gain and dark count rates are presented, as well as temperature dependencies of some of these parameters. In a small fraction of the MRS APDs, some strange dips in the I-V curves just preceding the breakdown voltage point have been observed.

  19. MeV X-ray imaging using plastic scintillating fiber area detectors: a simulation study.

    Science.gov (United States)

    Tang, Shi-Biao; Ma, Qingli; Yin, Zejie; Zhu, Daming

    2008-02-01

    Due to their low cost, flexibility, and convenience for long distance data transfer, plastic scintillating fibers (PSFs) have been increasingly used in building detectors or sensors for detecting various radiations and imaging. In this work, the possibility of using PSF coupled with charge-coupled devices (CCD) to build area detectors for X-ray imaging is studied using a Monte Carlo simulation. The focus is on X-ray imaging with energy from a few 100 keV to about 20 MeV. It is found that the efficiency of PSF in detecting X-ray in this energy range is low. The performance can be improved by coating a PSF with X-ray absorption layers and the MTF of the system is presented. It seems possible to build such area detectors with PSFs for imaging hard X-rays under certain environment.

  20. High-pressure plastic scintillation detector for measuring radiogenic gases in flow systems

    CERN Document Server

    Schell, W R; Yoon, S R; Tobin, M J

    1999-01-01

    Radioactive gases are emitted into the atmosphere from nuclear electric power and nuclear fuel reprocessing plants, from hospitals discarding xenon used in diagnostic medicine, as well as from nuclear weapons tests. A high-pressure plastic scintillation detector was constructed to measure atmospheric levels of such radioactive gases by detecting the beta and internal conversion (IC) electron decays. Operational tests and calibrations were made that permit integration of the flow detectors into a portable Gas Analysis, Separation and Purification system (GASP). The equipment developed can be used for measuring fission gases released from nuclear reactor sources and/or as part of monitoring equipment for enforcing the Comprehensive Test Ban Treaty. The detector is being used routinely for in-line gas separation efficiency measurements, at the elevated operational pressures used for the high-pressure swing analysis system (2070 kPa) and at flow rates of 5-15 l/min . This paper presents the design features, opera...

  1. Development of a fast plastic scintillation detector with time resolution of less than 10 ps

    CERN Document Server

    Zhao, J W; Tanihata, I; Terashima, S; Zhu, L H; Enomoto, A; Nagae, D; Nishimura, T; Omika, S; Ozawa, A; Takeuchi, Y; Yamaguchi, T

    2016-01-01

    Timing-pick up detectors with excellent timing resolutions are essential in many modern nuclear physics experiments. Aiming to develop a Time-Of-Flight system with precision down to about 10 ps, we have made a systematic study of the timing characteristic of TOF detectors, which consist of several combinations of plastic scintillators and photomultiplier tubes. With the conventional electronics, the best timing resolution of about 5.1 ps ({\\sigma}) has been achieved for detectors with an area size of 3x1 cm2. It is found that for data digitalization a combination of TAC and ADC can achieve a better time resolution than currently available TDC. Simultaneously measurements of both time and pulse height are very valuable for correction of time-walk effect.

  2. Reaching time resolution of less than 10 ps with plastic scintillation detectors

    Science.gov (United States)

    Zhao, J. W.; Sun, B. H.; Tanihata, I.; Terashima, S.; Zhu, L. H.; Enomoto, A.; Nagae, D.; Nishimura, T.; Omika, S.; Ozawa, A.; Takeuchi, Y.; Yamaguchi, T.

    2016-07-01

    Timing-pick up detectors with excellent timing resolutions are essential in many modern nuclear physics experiments. Aiming to develop a Time-Of-Flight system with precision down to about 10 ps, we have made a systematic study of the timing characteristic of TOF detectors, which consist of several combinations of plastic scintillators and photomultiplier tubes. With the conventional electronics, the best timing resolution of about 5.1 ps (σ) has been achieved for detectors with an area size of 3 × 1cm2 . It is found that for data digitalization a combination of TAC and ADC can achieve a better time resolution than the currently available TDC. Simultaneous measurements of both time and pulse height are very valuable for the correction of time-walk effect.

  3. The customized groud test platforms for the plastic scintillator detector of DAMPE

    Science.gov (United States)

    Zhou, Yong; Sun, Zhiyu; Yu, Yuhong; Fang, Fang; Chen, Junling; Zhang, Yongjie

    2016-07-01

    The DArk Matter Particle Explorer (DAMPE) is a high-precision satellite-borne spectrometer aiming for dark matter search, understanding of the origin and propagation of cosmic rays and gamma-ray astronomy. The Plastic Scintillator Detector (PSD) is a key sub-detector of DAMPE, which provides the function of e/γ discrimination and charge measurement from proton to calcium. It consists of 82 plastic scintillator bars with the dimension of 884mm×28mm×10mm, each readout by two photomultiplier tubes (PMT) at both ends. To ensure the quality and achieve the best performance, various ground tests have been carried out during the construction phase of PSD both on the module and system scale. Customized test platforms are designed and constructed to facilitate these works which includes a test bench for batch PMT characterization and qualification with the capacity of 25 tubes, a test bench for batch scintillator bar characterization with the capacity of 24 bars, and an integrated platform which emulates the vacuum condition in space and provides accurate tracking of the incident cosmic ray particle for precise calibration of the PSD detector as a whole. A dedicated analysis software based on ROOT library has also been developed for PSD ground test, which can process both the engineering and science data, and combines decoding, analysis and data visualization into a single framework. These facilities constitute a complete test suite for PSD development and are applied successfully in the construction of both the Engineering Qualified Model and the Flight Model of PSD.

  4. Performance assessment of a 2D array of plastic scintillation detectors for IMRT quality assurance

    Science.gov (United States)

    Guillot, Mathieu; Gingras, Luc; Archambault, Louis; Beddar, Sam; Beaulieu, Luc

    2013-07-01

    The purposes of this work are to assess the performance of a 2D plastic scintillation detectors array prototype for quality assurance in intensity-modulated radiation therapy (IMRT) and to determine its sensitivity and specificity to positioning errors of one multileaf collimator (MLC) leaf and one MLC leaf bank by applying the principles of signal detection theory. Ten treatment plans (step-and-shoot delivery) and one volumetric modulated arc therapy plan were measured and compared to calculations from two treatment-planning systems (TPSs) and to radiochromic films. The averages gamma passing rates per beam found for the step-and-shoot plans were 95.8% for the criteria (3%, 2 mm), 97.8% for the criteria (4%, 2 mm), and 98.1% for the criteria (3%, 3 mm) when measurements were compared to TPS calculations. The receiver operating characteristic curves for the one leaf errors and one leaf bank errors were determined from simulations (theoretical upper limits) and measurements. This work concludes that arrays of plastic scintillation detectors could be used for IMRT quality assurance in clinics. The use of signal detection theory could improve the quality of dosimetric verifications in radiation therapy by providing optimal discrimination criteria for the detection of different classes of errors.

  5. Study of a detector system for high-energy astrophysical objects using a combination of plastic scintillator and MPPC

    Energy Technology Data Exchange (ETDEWEB)

    Nakaoka, Tatsuya; Mizuno, Tsunefumi; Takahashi, Hiromitsu; Fukazawa, Yasushi

    2016-09-21

    We have investigated a hard X-ray detector system using a combination of a plastic scintillator and multi-pixel photon counters (MPPC). Photomultiplier tubes (PMTs) have typically been adopted to read scintillators because of their high gain and large photoelectric surface, and studies on PMT and scintillator systems are well advanced. However, PMTs have limitations; for example, they are relatively large in size, require high voltage to operate, and cannot be used in strong magnetic fields. On the other hand, MPPCs do not have such limitations and instead possess high quantum efficiency and a large compact size. Therefore, we have studied a detector system that combines an MPPC with a plastic scintillator. The system is primarily intended to be used for polarization measurements of high-energy astrophysical objects. We achieved an energy threshold of as low as ~5 keV while operating the detector at low temperature (−10 °C), reading the signal with short integration time (50 ns), and using a low-noise MPPC. We also confirmed that the light yield of our MPPC+plastic scintillator system is comparable to that obtained using a conventional PMT to read the scintillator signal. Herein, we report test results and future prospects.

  6. Extruded plastic scintillator for MINERvA

    Energy Technology Data Exchange (ETDEWEB)

    Pla-Dalmau, Anna; Bross, Alan D.; /Fermilab; Rykalin, Victor V.; Wood, Brian M.; /NICADD, DeKalb

    2005-11-01

    An extrusion line has recently been installed at Fermilab in collaboration with NICADD (Northern Illinois Center for Accelerator and Detector Development). This new facility will serve to further develop and improve extruded plastic scintillator. Since polystyrene is widely used in the consumer industry, the logical path was to investigate the extrusion of commercial-grade polystyrene pellets with dopants to yield high quality plastic scintillator. The D0 and MINOS experiments are already using extruded scintillator strips in their detectors. A new experiment at Fermilab is pursuing the use of extruded plastic scintillator. A new plastic scintillator strip is being tested and its properties characterized. The initial results are presented here.

  7. A systematic characterization of the low-energy photon response of plastic scintillation detectors

    Science.gov (United States)

    Boivin, Jonathan; Beddar, Sam; Bonde, Chris; Schmidt, Daniel; Culberson, Wesley; Guillemette, Maxime; Beaulieu, Luc

    2016-08-01

    To characterize the low energy behavior of scintillating materials used in plastic scintillation detectors (PSDs), 3 PSDs were developed using polystyrene-based scintillating materials emitting in different wavelengths. These detectors were exposed to National Institute of Standards and Technology (NIST)-matched low-energy beams ranging from 20 kVp to 250 kVp, and to 137Cs and 60Co beams. The dose in polystyrene was compared to the dose in air measured by NIST-calibrated ionization chambers at the same location. Analysis of every beam quality spectrum was used to extract the beam parameters and the effective mass energy-absorption coefficient. Monte Carlo simulations were also performed to calculate the energy absorbed in the scintillators’ volume. The scintillators’ expected response was then compared to the experimental measurements and an energy-dependent correction factor was identified to account for low-energy quenching in the scintillators. The empirical Birks model was then compared to these values to verify its validity for low-energy electrons. The clear optical fiber response was below 0.2% of the scintillator’s light for x-ray beams, indicating that a negligible amount of fluorescence contamination was produced. However, for higher-energy beams (137Cs and 60Co), the scintillators’ response was corrected for the Cerenkov stem effect. The scintillators’ response increased by a factor of approximately 4 from a 20 kVp to a 60Co beam. The decrease in sensitivity from ionization quenching reached a local minimum of about 11%+/- 1% between 40 keV and 60 keV x-ray beam mean energy, but dropped by 20% for very low-energy (13 keV) beams. The Birks model may be used to fit the experimental data, but it must take into account the energy dependence of the kB quenching parameter. A detailed comprehension of intrinsic scintillator response is essential for proper calibration of PSD dosimeters for radiology.

  8. Investigations of surface coatings to reduce memory effect in plastic scintillator detectors used for radioxenon detection

    Science.gov (United States)

    Bläckberg, L.; Fay, A.; Jõgi, I.; Biegalski, S.; Boman, M.; Elmgren, K.; Fritioff, T.; Johansson, A.; Mårtensson, L.; Nielsen, F.; Ringbom, A.; Rooth, M.; Sjöstrand, H.; Klintenberg, M.

    2011-11-01

    In this work Al2O3 and SiO2 coatings are tested as Xe diffusion barriers on plastic scintillator substrates. The motivation is improved beta-gamma coincidence detection systems, used to measure atmospheric radioxenon within the verification regime of the Comprehensive Nuclear-Test-Ban Treaty. One major drawback with the current setup of these systems is that the radioxenon tends to diffuse into the plastic scintillator material responsible for the beta detection, resulting in an unwanted memory effect. Here, coatings with thicknesses between 20 and 900 nm have been deposited onto plastic scintillators, and investigated using two different experimental techniques. The results show that all tested coatings reduce the Xe diffusion into the plastic. The reduction is observed to increase with coating thickness for both coating materials. The 425 nm Al2O3 coating is the most successful one, presenting a diffusion reduction of a factor 100, compared to uncoated plastic. In terms of memory effect reduction this coating is thus a viable solution to the problem in question.

  9. Investigations of surface coatings to reduce memory effect in plastic scintillator detectors used for radioxenon detection

    Energy Technology Data Exchange (ETDEWEB)

    Blaeckberg, L., E-mail: lisa.blackberg@physics.uu.se [Department of Physics and Astronomy, Uppsala University, Box 516, SE-75120 Uppsala (Sweden); Fay, A. [University of Texas at Austin, Nuclear Engineering Teaching Lab, J.J. Pickle Research Campus, R-9000 Austin, TX (United States); Jogi, I. [Department of Materials Chemistry, Uppsala University, Box 538, SE-75121 Uppsala (Sweden); Biegalski, S. [University of Texas at Austin, Nuclear Engineering Teaching Lab, J.J. Pickle Research Campus, R-9000 Austin, TX (United States); Boman, M. [Department of Materials Chemistry, Uppsala University, Box 538, SE-75121 Uppsala (Sweden); Elmgren, K.; Fritioff, T. [Division of Defence and Security Systems, Swedish Defence Research Agency (FOI), SE-17290 Stockholm (Sweden); Johansson, A. [Nanexa AB, Virdings Alle 32B, SE-75450 Uppsala (Sweden); Martensson, L.; Nielsen, F.; Ringbom, A. [Division of Defence and Security Systems, Swedish Defence Research Agency (FOI), SE-17290 Stockholm (Sweden); Rooth, M. [Nanexa AB, Virdings Alle 32B, SE-75450 Uppsala (Sweden); Sjoestrand, H.; Klintenberg, M. [Department of Physics and Astronomy, Uppsala University, Box 516, SE-75120 Uppsala (Sweden)

    2011-11-11

    In this work Al{sub 2}O{sub 3} and SiO{sub 2} coatings are tested as Xe diffusion barriers on plastic scintillator substrates. The motivation is improved beta-gamma coincidence detection systems, used to measure atmospheric radioxenon within the verification regime of the Comprehensive Nuclear-Test-Ban Treaty. One major drawback with the current setup of these systems is that the radioxenon tends to diffuse into the plastic scintillator material responsible for the beta detection, resulting in an unwanted memory effect. Here, coatings with thicknesses between 20 and 900 nm have been deposited onto plastic scintillators, and investigated using two different experimental techniques. The results show that all tested coatings reduce the Xe diffusion into the plastic. The reduction is observed to increase with coating thickness for both coating materials. The 425 nm Al{sub 2}O{sub 3} coating is the most successful one, presenting a diffusion reduction of a factor 100, compared to uncoated plastic. In terms of memory effect reduction this coating is thus a viable solution to the problem in question.

  10. Dosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Gagnon, Jean-Christophe; Theriault, Dany; Guillot, Mathieu; Archambault, Louis; Beddar, Sam; Gingras, Luc; Beaulieu, Luc [Departement de Physique, de Genie Physique et d' Optique, Universite Laval, Quebec, Quebec G1K 7P4 (Canada) and Departement de Radio-Oncologie, Hotel-Dieu de Quebec, Centre Hospitalier Universitaire de Quebec, Quebec G1R 2J6 (Canada); Departement de Radio-Oncologie, Hotel-Dieu de Quebec, Centre Hospitalier Universitaire de Quebec, Quebec G1R 2J6 (Canada); Departement de Physique, de Genie Physique et d' Optique, Universite Laval, Quebec, Quebec G1K 7P4 (Canada) and Departement de Radio-Oncologie, Hotel-Dieu de Quebec, Centre Hospitalier Universitaire de Quebec, Quebec G1R 2J6 (Canada); Department of Radiation Physics, Unit 94, University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 (United States); Departement de Physique, de Genie Physique et d' Optique, Universite Laval, Quebec, Quebec G1K 7P4 (Canada) and Departement de Radio-Oncologie, Hotel-Dieu de Quebec, Centre Hospitalier Universitaire de Quebec, Quebec G1R 2J6 (Canada)

    2012-01-15

    Purpose: To compare the performance of plastic scintillation detectors (PSD) for quality assurance (QA) in stereotactic radiosurgery conditions to a microion-chamber (IC), Gafchromic EBT2 films, 60 008 shielded photon diode (SD) and unshielded diodes (UD), and assess a new 2D crosshair array prototype adapted to small field dosimetry. Methods: The PSD consists of a 1 mm diameter by 1 mm long scintillating fiber (BCF-60, Saint-Gobain, Inc.) coupled to a polymethyl-methacrylate optical fiber (Eska premier, Mitsubishi Rayon Co., Ltd., Tokyo, Japan). Output factors (S{sub c,p}) for apertures used in radiosurgery ranging from 4 to 40 mm in diameter have been measured. The PSD crosshair array (PSDCA) is a water equivalent device made up of 49 PSDs contained in a 1.63 cm radius area. Dose profiles measurements were taken for radiosurgery fields using the PSDCA and were compared to other dosimeters. Moreover, a typical stereotactic radiosurgery treatment using four noncoplanar arcs was delivered on a spherical phantom in which UD, IC, or PSD was placed. Using the Xknife planning system (Integra Radionics Burlington, MA), 15 Gy was prescribed at the isocenter, where each detector was positioned. Results: Output Factors measured by the PSD have a mean difference of 1.3% with Gafchromic EBT2 when normalized to a 10 x 10 cm{sup 2} field, and 1.0% when compared with UD measurements normalized to the 35 mm diameter cone. Dose profiles taken with the PSD crosshair array agreed with other single detectors dose profiles in spite of the presence of the 49 PSDs. Gamma values comparing 1D dose profiles obtained with PSD crosshair array with Gafchromic EBT2 and UD measured profiles shows 98.3% and 100.0%, respectively, of detector passing the gamma acceptance criteria of 0.3 mm and 2%. The dose measured by the PSD for a complete stereotactic radiosurgery treatment is comparable to the planned dose corrected for its SD-based S{sub c,p} within 1.4% and 0.7% for 5 and 35 mm diameter cone

  11. Multi-layer plastic scintillation detector for intermediate- and high-energy neutrons with n- γ discrimination capability

    Science.gov (United States)

    Yu, L.; Terashima, S.; Ong, H. J.; Chan, P. Y.; Tanihata, I.; Iwamoto, C.; Tran, D. T.; Tamii, A.; Aoi, N.; Fujioka, H.; Gey, G.; Sakaguchi, H.; Sakaue, A.; Sun, B. H.; Tang, T. L.; Wang, T. F.; Watanabe, Y. N.; Zhang, G. X.

    2017-09-01

    A new type of neutron detector, named Stack Structure Solid organic Scintillator (S4), consisting of multi-layer plastic scintillators with capability to suppress low-energy γ rays under high-counting rate has been constructed and tested. To achieve n- γ discrimination, we exploit the difference in the ranges of the secondary charged particles produced by the interactions of neutrons and γ rays in the scintillator material. The thickness of a plastic scintillator layer was determined based on the results of Monte Carlo simulations using the Geant4 toolkit. With layer thicknesses of 5 mm, we have achieved a good separation between neutrons and γ rays at 5 MeVee threshold setting. We have also determined the detection efficiencies using monoenergetic neutrons at two energies produced by the d + d → n+3He reaction. The results agree well with the Geant4 simulations implementing the Li e ̀ge Intranuclear Cascade hadronic model (INCL++) and the high-precision model of low-energy neutron interactions (NeutronHP).

  12. Subnanosecond Scintillation Detector

    Science.gov (United States)

    Hoenk, Michael (Inventor); Hennessy, John (Inventor); Hitlin, David (Inventor)

    2017-01-01

    A scintillation detector, including a scintillator that emits scintillation; a semiconductor photodetector having a surface area for receiving the scintillation, wherein the surface area has a passivation layer configured to provide a peak quantum efficiency greater than 40% for a first component of the scintillation, and the semiconductor photodetector has built in gain through avalanche multiplication; a coating on the surface area, wherein the coating acts as a bandpass filter that transmits light within a range of wavelengths corresponding to the first component of the scintillation and suppresses transmission of light with wavelengths outside said range of wavelengths; and wherein the surface area, the passivation layer, and the coating are controlled to increase the temporal resolution of the semiconductor photodetector.

  13. Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range

    Energy Technology Data Exchange (ETDEWEB)

    Lessard, Francois; Archambault, Louis; Plamondon, Mathieu [Departement de physique, de genie physique et d' optique, Universite Laval, Quebec, Quebec G1K 7P4, Canada and Departement de radio-oncologie, Hotel-Dieu de Quebec, Centre hospitalier universitaire de Quebec, Quebec G1R 2J6 (Canada); Departement de physique, de genie physique et d' optique, Universite Laval, Quebec, Quebec G1K 7P4 (Canada); Departement de radio-oncologie, Hotel-Dieu de Quebec, Centre hospitalier universitaire de Quebec, Quebec G1R 2J6 (Canada) and Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States); Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States); Departement de physique, de genie physique et d' optique, Universite Laval, Quebec, Quebec G1K 7P4, Canada and Departement de radio-oncologie, Hotel-Dieu de Quebec, Centre hospitalier universitaire de Quebec, Quebec G1R 2J6 (Canada); and others

    2012-09-15

    Purpose: Photon dosimetry in the kilovolt (kV) energy range represents a major challenge for diagnostic and interventional radiology and superficial therapy. Plastic scintillation detectors (PSDs) are potentially good candidates for this task. This study proposes a simple way to obtain accurate correction factors to compensate for the response of PSDs to photon energies between 80 and 150 kVp. The performance of PSDs is also investigated to determine their potential usefulness in the diagnostic energy range. Methods: A 1-mm-diameter, 10-mm-long PSD was irradiated by a Therapax SXT 150 unit using five different beam qualities made of tube potentials ranging from 80 to 150 kVp and filtration thickness ranging from 0.8 to 0.2 mmAl + 1.0 mmCu. The light emitted by the detector was collected using an 8-m-long optical fiber and a polychromatic photodiode, which converted the scintillation photons to an electrical current. The PSD response was compared with the reference free air dose rate measured with a calibrated Farmer NE2571 ionization chamber. PSD measurements were corrected using spectra-weighted corrections, accounting for mass energy-absorption coefficient differences between the sensitive volumes of the ionization chamber and the PSD, as suggested by large cavity theory (LCT). Beam spectra were obtained from x-ray simulation software and validated experimentally using a CdTe spectrometer. Correction factors were also obtained using Monte Carlo (MC) simulations. Percent depth dose (PDD) measurements were compensated for beam hardening using the LCT correction method. These PDD measurements were compared with uncorrected PSD data, PDD measurements obtained using Gafchromic films, Monte Carlo simulations, and previous data. Results: For each beam quality used, the authors observed an increase of the energy response with effective energy when no correction was applied to the PSD response. Using the LCT correction, the PSD response was almost energy independent, with

  14. Neutron detection and multiplicity counting using a boron-loaded plastic scintillator/bismuth germanate phoswich detector array

    Energy Technology Data Exchange (ETDEWEB)

    Miller, M.C.

    1998-03-01

    Neutron detection and multiplicity counting has been investigated using a boron-loaded plastic scintillator/bismuth germanate phoswich detector array. Boron-loaded plastic combines neutron moderation (H) and detection ({sup 10}B) at the molecular level, thereby physically coupling increasing detection efficiency and decreasing die-away time with detector volume. Both of these characteristics address a fundamental limitation of thermal-neutron multiplicity counters, where {sup 3}He proportional counters are embedded in a polyethylene matrix. Separation of the phoswich response into its plastic scintillator and bismuth germanate components was accomplished on a pulse-by-pulse basis using custom integrator and timing circuits. In addition, a custom time-tag module was used to provide a time for each detector event. Analysis of the combined energy and time event stream was performed by calibrating each detector`s response and filtering based on the presence of a simultaneous energy deposition corresponding to the {sup 10}B(n,alpha) reaction products in the plastic scintillator (93 keV{sub ee}) and the accompanying neutron-capture gamma ray in the bismuth germanate (478 keV). Time-correlation analysis was subsequently performed on the filtered event stream to obtain shift-register-type singles and doubles count rates. Proof-of-principle measurements were conducted with a variety of gamma-ray and neutron sources including {sup 137}Cs, {sup 54}Mn, AmLi, and {sup 252}Cf. Results of this study indicate that a neutron-capture probability of {approximately}10% and a die-away time of {approximately}10 {micro}s are possible with a 4-detector array with a detector volume of 1600 cm{sup 3}. Simulations were performed that indicate neutron-capture probabilities on the order of 50% and die-away times of less than 4 {micro}s are realistically achievable. While further study will be required for practical application of such a detection system, the results obtained in this

  15. A high-granularity plastic scintillator tile hadronic calorimeter with APD readout for a linear collider detector

    Energy Technology Data Exchange (ETDEWEB)

    Andreev, V. [Lebedev Physics Institute, Moscow (Russian Federation); Cvach, J. [Institute of Physics, Academy of Sciences of the Czech Republic, Prague (Czech Republic); Danilov, M. [Institute of Theoretical and Experimental Physics, Moscow (Russian Federation); Devitsin, E. [Lebedev Physics Institute, Moscow (Russian Federation); Dodonov, V. [DESY, Hamburg (Germany); Eigen, G. [DESY, Hamburg (Germany)]. E-mail: gerald.eigen@ift.uib.no; Garutti, E. [DESY, Hamburg (Germany); Gilitzky, Yu. [Institute of Theoretical and Experimental Physics, Moscow (Russian Federation); Groll, M. [University of Hamburg (Germany); Heuer, R.-D. [University of Hamburg (Germany); Janata, M. [Institute of Physics, Academy of Sciences of the Czech Republic, Prague (Czech Republic); Kacl, I. [Institute of Physics, Academy of Sciences of the Czech Republic, Prague (Czech Republic); Korbel, V. [DESY, Hamburg (Germany); Kozlov, V. [Lebedev Physics Institute, Moscow (Russian Federation); Meyer, H. [University of Hamburg (Germany); Morgunov, V. [Institute of Theoretical and Experimental Physics, Moscow (Russian Federation); Nemecek, S. [Institute of Physics, Academy of Sciences of the Czech Republic, Prague (Czech Republic); Poeschl, R. [DESY, Hamburg (Germany); Polak, I. [Institute of Physics, Academy of Sciences of the Czech Republic, Prague (Czech Republic); Raspereza, A. [DESY, Hamburg (Germany); Reiche, S. [University of Hamburg (Germany); Rusinov, V. [Institute of Theoretical and Experimental Physics, Moscow (Russian Federation); Sefkow, F. [DESY, Hamburg (Germany); Smirnov, P. [Lebedev Physics Institute, Moscow (Russian Federation); Terkulov, A. [Lebedev Physics Institute, Moscow (Russian Federation); Valkar, S. [Faculty of Mathematics and Physics, Charles University, Prague (Czech Republic); Weichert, J.; Zalesak, J. [Institute of Physics, Academy of Sciences of the Czech Republic, Prague (Czech Republic)

    2006-08-01

    We report upon the performance of an analog hadron calorimeter prototype, where plastic scintillator tiles are read out with wavelength-shifting fibers coupled to avalanche photodiodes. This prototype configuration has been tested using a positron beam at DESY with energies between 1 and 6 GeV. We present different detector calibration methods, show measurements for noise, linearity, and energy resolution and discuss gain monitoring with an LED system. The results are in good agreement with our simulation studies and previous measurements using silicon photomultiplier readout.

  16. Microfluidic Scintillation Detectors

    CERN Multimedia

    Microfluidic scintillation detectors are devices of recent introduction for the detection of high energy particles, developed within the EP-DT group at CERN. Most of the interest for such technology comes from the use of liquid scintillators, which entails the possibility of changing the active material in the detector, leading to an increased radiation resistance. This feature, together with the high spatial resolution and low thickness deriving from the microfabrication techniques used to manufacture such devices, is desirable not only in instrumentation for high energy physics experiments but also in medical detectors such as beam monitors for hadron therapy.

  17. SHIELDING AND DETECTOR RESPONSE CALCULATIONS PERTAINING TO CATEGORY 1 QUANTITIES OF PLUTONIUM AND HAND-HELD PLASTIC SCINTILLATORS

    Energy Technology Data Exchange (ETDEWEB)

    Couture, A.

    2013-06-07

    Nuclear facilities sometimes use hand-held plastic scintillator detectors to detect attempts to divert special nuclear material in situations where portal monitors are impractical. MCNP calculations have been performed to determine the neutron and gamma radiation field arising from a Category I quantity of weapons-grade plutonium in various shielding configurations. The shields considered were composed of combinations of lead and high-density polyethylene such that the mass of the plutonium plus shield was 22.7 kilograms. Monte-Carlo techniques were also used to determine the detector response to each of the shielding configurations. The detector response calculations were verified using field measurements of high-, medium-, and low- energy gamma-ray sources as well as a Cf-252 neutron source.

  18. Neutron induced radiation damage of plastic scintillators for the upgrade of the Tile Calorimeter of the ATLAS detector.

    Science.gov (United States)

    Mdhluli, J. E.; Jivan, H.; Erasmus, R.; Davydov, Yu I.; Baranov, V.; Mthembu, S.; Mellado, B.; Sideras-Haddad, E.; Solovyanov, O.; Sandrock, C.; Peter, G.; Tlou, S.; Khanye, N.; Tjale, B.

    2017-07-01

    With the prediction that the plastic scintillators in the gap region of the Tile Calorimeter will sustain a significantly large amount of radiation damage during the HL-LHC run time, the current plastic scintillators will need to be replaced during the phase 2 upgrade in 2018. The scintillators in the gap region were exposed to a radiation environment of up to 10 kGy/year during the first run of data taking and with the luminosity being increased by a factor of 10, the radiation environment will be extremely harsh. We report on the radiation damage to the optical properties of plastic scintillators following irradiation using a neutron beam of the IBR-2 pulsed reactor in Joint Institute for Nuclear Research (JINR), Dubna. A comparison is drawn between polyvinyl toluene based commercial scintillators EJ200, EJ208 and EJ260 as well as polystyrene based scintillator from Kharkov. The samples were subjected to irradiation with high energy neutrons and a flux density range of 1 × 106-7.7 × 106. Light transmission, Raman spectroscopy, fluorescence spectroscopy and light yield testing was performed to characterize the damage induced in the samples. Preliminary results from the tests done indicate a minute change in the optical properties of the scintillators with further studies underway to gain a better understanding of the interaction between neutrons with plastic scintillators.

  19. Fluorescent compounds for plastic scintillation applications

    Energy Technology Data Exchange (ETDEWEB)

    Pla-Dalmau, A.; Bross, A.D.

    1994-04-01

    Several 2-(2{prime}-hydroxyphenyl)benzothiazole, -benzoxazole, and -benzimidazole derivatives have been prepared. Transmittance, fluorescence, light yield, and decay time characteristics of these compounds have been studied in a polystyrene matrix and evaluated for use in plastic scintillation detectors. Radiation damage studies utilizing a {sup 60}C source have also been performed.

  20. Scintillating fiber detector

    CERN Document Server

    Vozak, Matous

    2016-01-01

    NA61 is one of the physics experiments at CERN dedicated to study hadron states coming from interactions of SPS beams with various targets. To determine the position of a secondary beam, three proportional chambers are placed along the beamline. However, these chambers tend to have slow response. In order to obtain more precise time information, use of another detector is being considered. Fast response and compact size is making scintillation fiber (SciFi) with silicon photomultiplier (Si-PM) read out a good candidate. This report is focused on analysing data from SciFi collected in a test beam at the beginning of July 2016.

  1. Combined scintillation detector for gamma dose rate measurement

    Energy Technology Data Exchange (ETDEWEB)

    Viererbl, L.; Novakova, O.; Jursova, L. (Tesla, Premysleni (Czechoslovakia). Vyzkumny Ustav Pristroju Jaderne Techniky)

    1990-01-01

    The specifications are described of a newly developed scintillation detector, essentially consisting of a plastic scintillator completed with inorganic scintillators ZnS(Ag) and NaI(Tl). The gamma dose rate is derived from the photomultiplier anode current. The composition and sizes of the scintillators and the capsule are selected so as to minimise the energy dependence errors and directional dependence errors of the detector response over a wide range of energies and/or angles. (author).

  2. PLASTIC SCINTILLATOR FOR RADIATION DOSIMETRY.

    Science.gov (United States)

    Kim, Yewon; Yoo, Hyunjun; Kim, Chankyu; Lim, Kyung Taek; Moon, Myungkook; Kim, Jongyul; Cho, Gyuseong

    2016-09-01

    Inorganic scintillators, composed of high-atomic-number materials such as the CsI(Tl) scintillator, are commonly used in commercially available a silicon diode and a scintillator embedded indirect-type electronic personal dosimeters because the light yield of the inorganic scintillator is higher than that of an organic scintillator. However, when it comes to tissue-equivalent dose measurements, a plastic scintillator such as polyvinyl toluene (PVT) is a more appropriate material than an inorganic scintillator because of the mass energy absorption coefficient. To verify the difference in the absorbed doses for each scintillator, absorbed doses from the energy spectrum and the calculated absorbed dose were compared. From the results, the absorbed dose of the plastic scintillator was almost the same as that of the tissue for the overall photon energy. However, in the case of CsI, it was similar to that of the tissue only for a photon energy from 500 to 4000 keV. Thus, the values and tendency of the mass energy absorption coefficient of the PVT are much more similar to those of human tissue than those of the CsI. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Characterization of a new plastic scintillation material and comparison with liquid BC-501A scintillator

    OpenAIRE

    Poleshchuk, Oleksii

    2015-01-01

    In this work the capability of various scintillation materials to discriminate gamma rays and neutrons were studied. Also such basic properties of scintillators as light emission spectrum and light output were determined. The studied materials were BC-501A liquid scintillator and a plastic scintillator provided by CEA. An experimental setup consisting of detector shielding, analog and digital electronics and data acquisition system was built to study the neutron-gamma discrimination propertie...

  4. Scintillation detectors of Alborz-I experiment

    Energy Technology Data Exchange (ETDEWEB)

    Pezeshkian, Yousef [Department of Physics, Sharif University of Technology, P.O.Box 11155-9161, Tehran (Iran, Islamic Republic of); Alborz Observatory, Sharif University of Technology, P.O.Box 11155-9161, Tehran (Iran, Islamic Republic of); Bahmanabadi, Mahmud, E-mail: bahmanabadi@sharif.edu [Department of Physics, Sharif University of Technology, P.O.Box 11155-9161, Tehran (Iran, Islamic Republic of); Alborz Observatory, Sharif University of Technology, P.O.Box 11155-9161, Tehran (Iran, Islamic Republic of); Abbasian Motlagh, Mehdi; Rezaie, Masume [Alborz Observatory, Sharif University of Technology, P.O.Box 11155-9161, Tehran (Iran, Islamic Republic of)

    2015-02-11

    A new air shower experiment of the Alborz Observatory, Alborz-I, located at the Sharif University of Technology, Iran, will be constructed in near future. An area of about 30×40 m{sup 2} will be covered by 20 plastic scintillation detectors (each with an area of 50×50 cm{sup 2}). A series of experiments have been performed to optimize the height of light enclosures of the detectors for this array and the results have been compared to an extended code simulation of these detectors. Operational parameters of the detector obtained by this code are cross checked by the Geant4 simulation. There is a good agreement between the extended-code and Geant4 simulations. We also present further discussions on the detector characteristics, which can be applicable for all scintillation detectors with a similar configuration.

  5. Scintillation detectors of Alborz-I experiment

    CERN Document Server

    Pezeshkian, Yousef; Motlagh, Mehdi Abbasian; Rezaie, Masoume

    2014-01-01

    A new air shower experiment of the Alborz Observatory, Alborz-I, located at the Sharif University of Technology, Iran, will be constructed in near future. An area of about 30$\\times$40 m$^{2}$ will be covered by 20 plastic scintillation detectors (each with an area of 50$\\times$50 cm$^{2}$). A series of experiments have been performed to optimize the height of light enclosures of the detectors for this array and the results have been compared to an extended code simulation of these detectors. Operational parameters of the detector obtained by this code are cross checked by Geant4 simulation. There is a good agreement between extended-code and Geant4 simulations. We also present further discussions on the detector characteristics, which can be applicable for all scintillation detectors with a similar configuration.

  6. Ultra-fast timing with plastic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Hoischen, Robert [Department of Physics, Lund University, S-22100 Lund (Sweden); Helmholtzzentrum fuer Schwerionenforschung GmbH, D-64291 Darmstadt (Germany); Pietri, Stephane; Prokopowicz, Wawrzyniec; Schaffner, Henning; Gerl, Juergen; Wollersheim, Hans Juergen; Kurz, Nikolaus [Helmholtzzentrum fuer Schwerionenforschung GmbH, D-64291 Darmstadt (Germany); Rudolph, Dirk [Department of Physics, Lund University, S-22100 Lund (Sweden)

    2009-07-01

    Fast timing detectors for time-of-flight measurements are essential identification tools for isotopes studied at fragment separators at major heavy-ion research facilities. While today's standard technique of utilizing a plastic scintillator read out by few photomultiplier tubes proofs to be efficient, it does not provide the required time resolution for future key experiments at, for example, the Super-FRS at FAIR. A common present-day approach is to use diamond detectors instead. While they do provide a better time resolution compared to scintillators, they are more difficult to use and far more expensive. Results from tests using a new design approach with standard materials will be presented. This leads to a much improved performance, but remains both cost-efficient, compact, and reliable. The design goals and how to accomplish them will be exemplified by the LYCCA (Lund-York-Cologne CAlorimeter) detector aiming for fast-beam experiments at HISPEC within NUSTAR.

  7. A new scintillating-fiber-array neutron detector

    CERN Document Server

    Zhang Qi; Xie Zhong Shen; Cao Jin Yun; Niu Shen Gli; Ouyang Xia Opin

    2002-01-01

    A new scintillating-fiber-array neutron detector has been developed. The detector consists of a bee-hive-shaped lead absorber, a scintillating fiber array, a light guide, a filter and a photomultiplier tube. The experimental results show that the new detector's neuron-to-gamma sensitivity ratio is improved about six times compared to traditional plastic scintillation detectors to 2.5 MeV neutrons and 1.25 MeV gamma rays. Hence, the detector should be very useful in the measurements of pulsed neutrons from fission reactions in a neutron-gamma mixed field.

  8. Characterization of liquid scintillation detectors

    CERN Document Server

    Schmidt, D; Böttger, R; Klein, H; Lebreton, L; Neumann, S; Nolte, R; Pichenot, G

    2002-01-01

    Five scintillation detectors of different scintillator size and type were characterized. The pulse height scale was calibrated in terms of electron light output units using photon sources. The response functions for time-of-flight (TOF)-selected monoenergetic neutrons were experimentally determined and also simulated with the NRESP code over a wide energy range. A comparison of the measured and calculated response functions allows individual characteristics of the detectors to be determined and the response matrix to be reliably derived. Various applications are discussed.

  9. Scintillation properties of acrylate based plastic scintillator by photoploymerization method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Hwan [Dept. of Radiological Science, Cheongju University, Cheongju (Korea, Republic of); Lee, Joo Il [Dept. of of Radiology, Daegu Health College, Daegu (Korea, Republic of)

    2016-12-15

    In this study, we prepared and characterized a acrylate based UV-curable plastic scintillator. It was used co-polymers TMPTA, DHPA and Ultima GoldTM LLT organic scintillator. The emission spectrum of the plastic scintillator was located in the range of 380⁓520 nm, peaking at 423 nm. And the scintillator is more than 50% transparent in the range of 400⁓ 800 nm. The emission spectrum is well match to the quantum efficiency of photo-multiplier tube and the fast decay time of the scintillation is 12 ns, approximately. This scintillation material provides the possibility of combining 3D printing technology, and then the applications of the plastic scintillator may be expected in human dosimetry etc.

  10. Light transport in long, plastic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Gierlik, M. [Soltan Institute for Nuclear Studies, PL 05-400 Swierk-Otwock (Poland)], E-mail: m.gierlik@ipj.gov.pl; Batsch, T.; Marcinkowski, R.; Moszynski, M.; Sworobowicz, T. [Soltan Institute for Nuclear Studies, PL 05-400 Swierk-Otwock (Poland)

    2008-08-11

    As a form of the input into the collaboration the group from the Andrzej Soltan Institute for Nuclear Studies undertook a task of investigating the validity of the design of a compact detector for Gamma Ray Bursts photon polarization measurements, known as POLAR. The authors focused at the scintillation and light transport properties of (200x6x6)mm{sup 3} BC400 plastic bars as well as of other samples of BC408 plastic in the attempt to determine whether the assembled instrument is going to achieve the performance criteria bestowed upon it by the project. The investigation revealed a strong dependence between the amplitude of a signal and distance between the precursor interaction in a scintillator and the photodetector. Accordingly to this finding an attempt has been made to determine the influence of the surface polishing quality on the overall scintillator performance. The authors consider that proper machining of scintillator pieces, adequate choice of their packaging, and proper software analysis may overcome the revealed disadvantages.

  11. Characterization of the scintillation anisotropy in crystalline stilbene scintillator detectors

    CERN Document Server

    Schuster, Patricia

    2016-01-01

    This paper reports a series of measurements that characterize the directional dependence of the scintillation response of crystalline melt-grown and solution-grown stilbene to incident DT and DD neutrons. These measurements give the amplitude and pulse shape dependence on the proton recoil direction over one hemisphere of the crystal, confirming and extending previous results in the literature for melt-grown stilbene and providing the first measurements for solution-grown stilbene. In similar measurements of liquid and plastic detectors, no directional dependence was observed, confirming the hypothesis that the anisotropy in stilbene and other organic crystal scintillators is a result of internal effects due to the molecular or crystal structure and not an external effect on the measurement system.

  12. Neutron spectroscopy with scintillation detectors using wavelets

    Science.gov (United States)

    Hartman, Jessica

    The purpose of this research was to study neutron spectroscopy using the EJ-299-33A plastic scintillator. This scintillator material provided a novel means of detection for fast neutrons, without the disadvantages of traditional liquid scintillation materials. EJ-299-33A provided a more durable option to these materials, making it less likely to be damaged during handling. Unlike liquid scintillators, this plastic scintillator was manufactured from a non-toxic material, making it safer to use, as well as easier to design detectors. The material was also manufactured with inherent pulse shape discrimination abilities, making it suitable for use in neutron detection. The neutron spectral unfolding technique was developed in two stages. Initial detector response function modeling was carried out through the use of the MCNPX Monte Carlo code. The response functions were developed for a monoenergetic neutron flux. Wavelets were then applied to smooth the response function. The spectral unfolding technique was applied through polynomial fitting and optimization techniques in MATLAB. Verification of the unfolding technique was carried out through the use of experimentally determined response functions. These were measured on the neutron source based on the Van de Graff accelerator at the University of Kentucky. This machine provided a range of monoenergetic neutron beams between 0.1 MeV and 24 MeV, making it possible to measure the set of response functions of the EJ-299-33A plastic scintillator detector to neutrons of specific energies. The response of a plutonium-beryllium (PuBe) source was measured using the source available at the University of Nevada, Las Vegas. The neutron spectrum reconstruction was carried out using the experimentally measured response functions. Experimental data was collected in the list mode of the waveform digitizer. Post processing of this data focused on the pulse shape discrimination analysis of the recorded response functions to remove the

  13. Performance comparison of scintillators for alpha particle detectors

    Science.gov (United States)

    Morishita, Yuki; Yamamoto, Seiichi; Izaki, Kenji; Kaneko, Junichi H.; Toui, Kohei; Tsubota, Youichi; Higuchi, Mikio

    2014-11-01

    Scintillation detectors for alpha particles are often used in nuclear fuel facilities. Alpha particle detectors have also become important in the research field of radionuclide therapy using alpha emitters. ZnS(Ag) is the most often used scintillator for alpha particle detectors because its light output is high. However, the energy resolution of ZnS(Ag)-based scintillation detectors is poor because they are not transparent. A new ceramic sample, namely the cerium doped Gd2Si2O7 (GPS) scintillator, has been tested as alpha particle detector and its performances have been compared to that one of three different scintillating materials: ZnS(Ag), GAGG and a standard plastic scintillator. The different scintillating materials have been coupled to two different photodetectors, namely a photomultiplier tube (PMT) and a Silicon Photo-multiplier (Si-PM): the performances of each detection system have been compared. Promising results as far as the energy resolution performances (10% with PMT and 14% with Si-PM) have been obtained in the case of GPS and GAGG samples. Considering the quantum efficiencies of the photodetectors under test and their relation to the emission wavelength of the different scintillators, the best results were achieved coupling the GPS with the PMT and the GAGG with the Si-PM

  14. Energy resolution of scintillation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Moszyński, M., E-mail: M.Moszynski@ncbj.gov.pl; Syntfeld-Każuch, A.; Swiderski, L.; Grodzicka, M.; Iwanowska, J.; Sibczyński, P.; Szczęśniak, T.

    2016-01-01

    According to current knowledge, the non-proportionality of the light yield of scintillators appears to be a fundamental limitation of energy resolution. A good energy resolution is of great importance for most applications of scintillation detectors. Thus, its limitations are discussed below; which arise from the non-proportional response of scintillators to gamma rays and electrons, being of crucial importance to the intrinsic energy resolution of crystals. The important influence of Landau fluctuations and the scattering of secondary electrons (δ-rays) on intrinsic resolution is pointed out here. The study on undoped NaI and CsI at liquid nitrogen temperature with a light readout by avalanche photodiodes strongly suggests that the non-proportionality of many crystals is not their intrinsic property and may be improved by selective co-doping. Finally, several observations that have been collected in the last 15 years on the influence of the slow components of light pulses on energy resolution suggest that more complex processes are taking place in the scintillators. This was observed with CsI(Tl), CsI(Na), ZnSe(Te), and undoped NaI at liquid nitrogen temperature and, finally, for NaI(Tl) at temperatures reduced below 0 °C. A common conclusion of these observations is that the highest energy resolution, and particularly intrinsic resolution measured with the scintillators, characterized by two or more components of the light pulse decay, is obtainable when the spectrometry equipment integrates the whole light of the components. In contrast, the slow components observed in many other crystals degrade the intrinsic resolution. In the limiting case, afterglow could also be considered as a very slow component that spoils the energy resolution. The aim of this work is to summarize all of the above observations by looking for their origin.

  15. A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Guillot, Mathieu; Beaulieu, Luc; Archambault, Louis; Beddar, Sam; Gingras, Luc [Departement de Physique, de Genie Physique et d' Optique, Universite Laval, Quebec, Quebec G1K 7P4 (Canada) and Departement de Radio-Oncologie, Hotel-Dieu de Quebec, Centre Hospitalier Universitaire de Quebec, Quebec, Quebec G1R 2J6 (Canada); Department of Radiation Physics, Unit 94, University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 (United States); Departement de Physique, de Genie Physique et d' Optique, Universite Laval, Quebec, Quebec G1K 7P4 (Canada) and Departement de Radio-Oncologie, Hotel-Dieu de Quebec, Centre Hospitalier Universitaire de Quebec, Quebec, Quebec G1R 2J6 (Canada)

    2011-12-15

    Purpose: The objective of this work is to present a new 2D plastic scintillation detectors array (2D-PSDA) designed for the dosimetry of megavoltage (MV) energy photon beams in radiation therapy and to characterize its basic performance. Methods: We developed a 2D detector array consisting of 781 plastic scintillation detectors (PSDs) inserted into a plane of a water-equivalent phantom. The PSDs were distributed on a 26 x 26 cm{sup 2} grid, with an interdetector spacing of 10 mm, except for two perpendicular lines centered on the detection plane, where the spacing was 5 mm. Each PSD was made of a 1 mm diameter by 3 mm long cylindrical polystyrene scintillating fiber coupled to a clear nonscintillating plastic optical fiber. All of the light signals emitted by the PSDs were read simultaneously with an optical system at a rate of one measurement per second. We characterized the performance of the optical system, the angular dependency of the device, and the perturbation of dose distributions caused by the hundreds of PSDs inserted into the phantom. We also evaluated the capacity of the system to monitor complex multileaf collimator (MLC) sequences such as those encountered in step-and-shoot intensity modulated radiation therapy (IMRT) plans. We compared our results with calculations performed by a treatment planning system and with measurements taken with a 2D ionization chamber array and with a radiochromic film. Results: The detector array that we developed allowed us to measure doses with an average precision of better than 1% for cumulated doses equal to or greater than 6.3 cGy. Our results showed that the dose distributions produced by the 6-MV photon beam are not perturbed (within {+-}1.1%) by the presence of the hundreds of PSDs located into the phantom. The results also showed that the variations in the beam incidences have little effect on the dose response of the device. For all incidences tested, the passing rates of the gamma tests between the 2D-PSDA and

  16. Gadolinium loaded plastic scintillators for high efficiency neutron detection

    Science.gov (United States)

    Ovechkina, Lena; Riley, Kent; Miller, Stuart; Bell, Zane; Nagarkar, Vivek

    2009-08-01

    Gadolinium has the highest thermal neutron absorption cross section of any naturally occurring element, and emits conversion electrons as well as atomic X-rays in over 50% of its neutron captures, which makes it a useful dopant in scintillators for detecting thermal neutrons. Gadolinium isopropoxide was studied as a possible dopant for styrene-based plastic scintillators as a convenient and inexpensive method to produce high-efficiency thermal neutron detectors. Plastic scintillators with gadolinium weight concentrations of up to 3% were transparent, uniform and defect-free and were characterized with spectral measurements performed under x-ray and neutron irradiation. The new material has the same characteristic emission of styrene with a maximum at approximately 425 nm, and a light output of 76% relative to the undoped plastic. A 13 mm thick sample containing 0.5% gadolinium by weight detected 46% of incident thermal neutrons, which makes this an attractive material for a variety of applications.

  17. Light output of EJ228 scintillation neutron detectors

    Energy Technology Data Exchange (ETDEWEB)

    Stevanato, L., E-mail: luca.stevanato@pd.infn.i [Dipartimento di Fisica dell' Universita di Padova, Via Marzolo 8, I-35131 Padova (Italy); Fabris, D. [INFN Sezione di Padova, Via Marzolo 8, I-35131 Padova (Italy); Hao, Xin [Dipartimento di Fisica dell' Universita di Padova, Via Marzolo 8, I-35131 Padova (Italy); Lunardon, M.; Moretto, S. [Dipartimento di Fisica dell' Universita di Padova, Via Marzolo 8, I-35131 Padova (Italy); INFN Sezione di Padova, Via Marzolo 8, I-35131 Padova (Italy); Nebbia, G.; Pesente, S. [INFN Sezione di Padova, Via Marzolo 8, I-35131 Padova (Italy); Sajo-Bohus, L. [Universidad Simon-Bolivar, Laboratorio Fisica Nuclear, Apartado 8900, 1080 A. Caracas (Venezuela, Bolivarian Republic of); Viesti, G. [Dipartimento di Fisica dell' Universita di Padova, Via Marzolo 8, I-35131 Padova (Italy); INFN Sezione di Padova, Via Marzolo 8, I-35131 Padova (Italy)

    2011-02-15

    The light output of neutron detectors based on the plastic scintillator EJ228 is studied as a function of neutron energy using a time tagged {sup 252}Cf source. Calibration of the light output scale is performed by fitting the experimental distribution of Compton scattering events of photons from a {sup 22}Na source with a response function obtained by Gaussian smearing of the predicted line-shape. The light output curve as well as the pulse height resolution for the EJ228 scintillators is very close (within 5%) to those recently reported for NE213 type organic liquid scintillators.

  18. Scintillation Detectors for Charged Particles and Photons

    CERN Document Server

    Lecoq, P

    2011-01-01

    Scintillation Detectors for Charged Particles and Photons in 'Charged Particle Detectors - Particle Detectors and Detector Systems', part of 'Landolt-Börnstein - Group I Elementary Particles, Nuclei and Atoms: Numerical Data and Functional Relationships in Science and Technology, Volume 21B1: Detectors for Particles and Radiation. Part 1: Principles and Methods'. This document is part of Part 1 'Principles and Methods' of Subvolume B 'Detectors for Particles and Radiation' of Volume 21 'Elementary Particles' of Landolt-Börnstein - Group I 'Elementary Particles, Nuclei and Atoms'. It contains the Subsection '3.1.1 Scintillation Detectors for Charged Particles and Photons' of Section '3.1 Charged Particle Detectors' of Chapter '3 Particle Detectors and Detector Systems' with the content: 3.1.1 Scintillation Detectors for Charged Particles and Photons 3.1.1.1 Basic detector principles and scintillator requirements 3.1.1.1.1 Interaction of ionizing radiation with scintillator material 3.1.1.1.2 Important scint...

  19. Advanced Large Area Plastic Scintillator Project (ALPS): Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, David V.; Reeder, Paul L.; Todd, Lindsay C.; Warren, Glen A.; McCormick, Kathleen R.; Stephens, Daniel L.; Geelhood, Bruce D.; Alzheimer, James M.; Crowell, Shannon L.; Sliger, William A.

    2008-02-05

    The advanced Large-Area Plastic Scintillator (ALPS) Project at Pacific Northwest National Laboratory investigated possible technological avenues for substantially advancing the state-of-the-art in gamma-ray detection via large-area plastic scintillators. The three predominant themes of these investigations comprised the following: * Maximizing light collection efficiency from a single large-area sheet of plastic scintillator, and optimizing hardware event trigger definition to retain detection efficiency while exploiting the power of coincidence to suppress single-PMT "dark current" background; * Utilizing anti-Compton vetoing and supplementary spectral information from a co-located secondary, or "Back" detector, to both (1) minimize Compton background in the low-energy portion of the "Front" scintillator's pulse-height spectrum, and (2) sharpen the statistical accuracy of the front detector's low-energy response prediction as impelmented in suitable energy-windowing algorithms; and * Investigating alternative materials to enhance the intrinsic gamma-ray detection efficiency of plastic-based sensors.

  20. Response of plastic scintillators to low-energy photons.

    Science.gov (United States)

    Peralta, Luis; Rêgo, Florbela

    2014-08-21

    Diagnostic radiology typically uses x-ray beams between 25 and 150 kVp. Plastic scintillation detectors (PSDs) are potentially successful candidates as field dosimeters but careful selection of the scintillator is crucial. It has been demonstrated that they can suffer from energy dependence in the low-energy region, an undesirable dosimeter characteristic. This dependence is partially due to the nonlinear light yield of the scintillator to the low-energy electrons set in motion by the photon beam. In this work, PSDs made of PMMA, PVT or polystyrene were studied for the x-ray beam range 25 to 100 kVp. For each kVp data has been acquired for additional aluminium filtrations of 0.5, 1.0, 2.0 and 4.0 mm. Absolute dose in the point of measurement was obtained with an ionization chamber calibrated to dose in water. From the collected data, detector sensitivities were obtained as function of the beam kVp and additional filtration. Using Monte Carlo simulations relative scintillator sensitivities were computed. For some of the scintillators these sensitivities show strong energy-dependence for beam average energy below 35 keV for each additional filtration but fair constancy above. One of the scintillators (BC-404) has smaller energy-dependence at low photon average energy and could be considered a candidate for applications (like mammography) where beam energy has small span.

  1. POSSuMUS: a position sensitive scintillating muon SiPM detector

    CERN Document Server

    Ruschke, Alexander

    The development of a modular designed large scale scintillation detector with a two-dimensional position sensitivity is presented in this thesis. This novel POsition Sensitive Scintillating MUon SiPM Detector is named POSSuMUS. The POSSuMUS detector is capable to determine the particle’s position in two space dimensions with a fast trigger capability. Each module is constructed from two trapezoidal shaped plastic scintillators to form one rectangular shaped detector module. Both trapezoids are optically insulated against each other. In both trapezoids the scintillation light is collected by plastic fibers and guided towards silicon photomultipliers (SiPMs). SiPMs are light sensors which are capable to detect even smallest amounts of light. By combining several detector modules, position sensitive areas from 100 cm2 to few m2 are achievable with few readout channels. Therefore, POSSuMUS provides a cost effective detector concept. The position sensitivity along the trapezoidal geometry of one detector module ...

  2. The investigation of timing large area scintillation detectors with SiPM light sensors properties

    Science.gov (United States)

    Runtso, M. F.; Naumov, P. Yu; Naumov, P. P.; Maklyaev, E. F.; Kaplin, V. A.; Fomin, V. S.; Razzhivin, I. S.; Melikyan, Yu A.

    2017-01-01

    The timing large area plastic scintillation detectors with silicon photomultipliers as photosensors properties were investigated using a cosmic radiation at the ground level. Different techniques of the amplitude spectra and efficiency measurements were implemented. The measurements results are presented.

  3. Decay Time Measurement for Different Energy Depositions of Plastic Scintillator Fabricated by High Temperature Polymerization Reaction

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Cheol Ho; Son, Jaebum; Lee, Sangmin; Kim, Tae Hoon; Kim, Yong-Kyun [Hanyang University, Seoul (Korea, Republic of)

    2016-10-15

    Plastic scintillators are based on organic fluorite. They have many advantages such as fast rise and decay time, high optical transmission, ease of manufacturing, low cost, and large available size. For these reasons they are widely used for particle identification. Also, protection of people against a variety of threats (such as nuclear, radiological, and explosive) represents a true challenge along with the continuing development of science and technology. The plastic scintillator is widely used in various devise, which serves for nuclear, photonics, quantum, and high-energy physics. The plastic scintillator is probably the most widely used organic detector, and polystyrene is one of the most widely used materials in the making of the plastic scintillator detector. Thus, a styrene monomer as a solvent was used to fabricate the plastic scintillator by using high temperature polymerization reaction, and then the emission wavelength and the decay times for different energy depositions were measured by using the fabricated plastic scintillator. A plastic scintillator was fabricated to measure decay time for different energy depositions using the high temperature polymerization. Emission wavelength was measured of 426.05 nm to confirm a scintillator property using the spectrophotometer. Four gamma-ray sources (Cs-137, Co-60, Na-22, and Ba-133) were used to evaluate effect for decay time of different energy depositions. The average decay time of the fabricated plastic scintillator was measured to approximately 4.72 ns slightly higher more than commercial plastic scintillator. In future, light output and linearity will be measured to evaluate other property compared with the commercial scintillator.

  4. Microfluidic Scintillation Detectors for High Energy Physics

    CERN Document Server

    Maoddi, Pietro; Mapelli, Alessandro

    This thesis deals with the development and study of microfluidic scintillation detectors, a technology of recent introduction for the detection of high energy particles. Most of the interest for such devices comes from the use of a liquid scintillator, which entails the possibility of changing the active material in the detector, leading to increased radiation resistance. A first part of the thesis focuses on the work performed in terms of design and modelling studies of novel prototype devices, hinting to new possibilities and applications. In this framework, the simulations performed to validate selected designs and the main technological choices made in view of their fabrication are addressed. The second part of this thesis deals with the microfabrication of several prototype devices. Two different materials were studied for the manufacturing of microfluidic scintillation detectors, namely the SU-8 photosensitive epoxy and monocrystalline silicon. For what concerns the former, an original fabrication appro...

  5. Scintillation detectors in computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Gilar, O.; Pavlicek, Z.; Jursova, L. (Tesla, Premysleni (Czechoslovakia). Vyzkumny Ustav Pristroju Jaderne Techniky)

    1984-07-01

    A new scintillator, Bi/sub 4/Ge/sub 3/O/sub 12/ (BGO), was tested for use in the detection part of computerized tomographs. In comparison with the NaI(Tl) scintillator it has a three-fold mass stopping power and allows the detection of medium and high energy gamma radiation with a higher detection efficiency, i.e., for the same detection efficiency its size is much smaller. Some other mechanical, physical and optical parameters of the BGO scintillator are given. BGO is prospective for use in high energy spectrometry and may replace NaI(Tl) wherever the following parameters are significant: crystal size, detection efficiency for gamma radiation, and good spatial resolution.

  6. Plastic scintillators modifications for a selective radiation detection

    Energy Technology Data Exchange (ETDEWEB)

    Hamel, Matthieu; Bertrand, Guillaume H.V.; Carrel, Frederick; Coulon, Romain; Dumazert, Jonathan; Montbarbon, Eva; Sguerra, Fabien [CEA, LIST, Laboratoire Capteurs and Architectures electroniques, 91191 Gif-sur-Yvette cedex (France)

    2015-07-01

    Recent developments of plastic scintillators are reviewed, from January 2000 to June 2015. All examples are distributed into the main application, i.e. how the plastic scintillator was modified to enhance the detection towards a given radiation particle. The main characteristics of these newly created scintillators and their detection properties are given. (authors)

  7. New Scintillation Detectors for PET

    NARCIS (Netherlands)

    Shah, K.S.

    2010-01-01

    The focus of this thesis is on new detection technologies that can be used in advancing nuclear medicine modalities, particularly positron emission tomography (PET). Several detection technologies are covered in this thesis. First, new Ce3+ doped rare earth trihalide scintillators that can be used

  8. New Scintillation Detectors for PET

    NARCIS (Netherlands)

    Shah, K.S.

    2010-01-01

    The focus of this thesis is on new detection technologies that can be used in advancing nuclear medicine modalities, particularly positron emission tomography (PET). Several detection technologies are covered in this thesis. First, new Ce3+ doped rare earth trihalide scintillators that can be used i

  9. Study Performance of Liquid Scintillation Fiber Detector

    CERN Document Server

    Zhang, Yongpeng; Lu, Haoqi; Zhang, Peng; Zhang, Chengcai; Yang, Changgen

    2016-01-01

    Liquid scintillator (LS) with optical fiber detector (LSOF detector) is a new type of detector, which has been applied in large-scale particle physics experiments in recent years. We were proposing LSOF detector as one option of top veto detector in Jiangmen Underground Neutrino Observatory (JUNO) experiment. The prototype detector was located in laboratory of the institute of high energy physics (IHEP). From prototype study, we found that the detector have a good performance and can satisfy JUNO requirement. The detection efficiency of cosmic ray muon is greater than 98% and can collect 58 photon electrons (p.e.) when muon is going through the detector. Further more, the relationship between p.e., material reflectivity and LS depth are studied. We also compared the data with Monte Carlo simulation, and they have a good agreement with each other.

  10. A simple technique for gamma ray and cosmic ray spectroscopy using plastic scintillator

    CERN Document Server

    Nandan, Akhilesh P; Neog, Himangshu; Bhuyan, M R; Biswas, S; Mahapatra, S; Mohanty, B; Mohanty, Rudranarayan; Rout, Subasha; Sahu, P K; Sahu, S; Sakthivel, V A; Samal, P K

    2014-01-01

    A new and simple technique has been developed using plastic scintillator detectors for gamma ray and cosmic ray spectroscopy without single channel analyzer (SCA) or multichannel analyzer (MCA). In these experiments only a leading edge discriminator (LED) and NIM scalers have been used. Energy calibration of gamma spectra in plastic scintillators has been done using Co60 and Cs137 sources. The details experimental technique, analysis procedure and experimental results has been presented in this article.

  11. Application of WLS strips for position determination in Strip PET tomograph based on plastic scintillators

    CERN Document Server

    Smyrski, J; Bednarski, T; Białas, P; Czerwiński, E; Kapłon, Ł; Kochanowski, A; Korcyl, G; Kowal, J; Kowalski, P; Kozik, T; Krzemień, W; Molenda, M; Niedźwiecki, Sz; Pałka, M; Pawlik, M; Raczyński, L; Rudy, Z; Salabura, P; Sharma, N G; Silarski, M; Słomski, A; Strzelecki, A; Wiślicki, W; Zieliński, M; Zoń, N

    2013-01-01

    A method of determination of a gamma quantum absorption point in a plastic scintillator block using a matrix of wavelength-shifting (WLS) strips is proposed. Application of this method for improvement of position resolution in newly proposed PET detectors based on plastic scintillators is presented. The method enables to reduce parallax errors in reconstruction of images which occurs in the presently used Positron Emission Tomography scanners.

  12. Semiconductor High-Energy Radiation Scintillation Detector

    CERN Document Server

    Kastalsky, A; Spivak, B

    2006-01-01

    We propose a new scintillation-type detector in which high-energy radiation produces electron-hole pairs in a direct-gap semiconductor material that subsequently recombine producing infrared light to be registered by a photo-detector. The key issue is how to make the semiconductor essentially transparent to its own infrared light, so that photons generated deep inside the semiconductor could reach its surface without tangible attenuation. We discuss two ways to accomplish this, one based on doping the semiconductor with shallow impurities of one polarity type, preferably donors, the other by heterostructure bandgap engineering. The proposed semiconductor scintillator combines the best properties of currently existing radiation detectors and can be used for both simple radiation monitoring, like a Geiger counter, and for high-resolution spectrography of the high-energy radiation. The most important advantage of the proposed detector is its fast response time, about 1 ns, essentially limited only by the recombi...

  13. The design of the TASD (totally active scintillator detector) prototype

    Energy Technology Data Exchange (ETDEWEB)

    Mefodiev, A. V., E-mail: Mefodiev@inr.ru; Kudenko, Yu. G. [Moscow Institute of Physics and Technology (State University) (Russian Federation)

    2015-12-15

    Totally active and magnetic segmented scintillation neutrino detectors are developed for the nextgeneration accelerator neutrino experiments. Such detectors will incorporate scintillation modules with scintillation counters that form X and Y planes. A single counter is a 7 × 10 × 90 mm{sup 3} scintillation bar with gluedin wavelength-shifting fibers and micropixel avalanche photodiodes. The results of measurements of the parameters of these detectors are presented.

  14. Plastic fiber scintillator response to fast neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Danly, C. R.; Sjue, S.; Wilde, C. H.; Merrill, F. E.; Haight, R. C. [Los Alamos National Laboratory, Los Alamos, New Mexico 87544 (United States)

    2014-11-15

    The Neutron Imaging System at NIF uses an array of plastic scintillator fibers in conjunction with a time-gated imaging system to form an image of the neutron emission from the imploded capsule. By gating on neutrons that have scattered from the 14.1 MeV DT energy to lower energy ranges, an image of the dense, cold fuel around the hotspot is also obtained. An unmoderated spallation neutron beamline at the Weapons Neutron Research facility at Los Alamos was used in conjunction with a time-gated imaging system to measure the yield of a scintillating fiber array over several energy bands ranging from 1 to 15 MeV. The results and comparison to simulation are presented.

  15. Comparing the response of PSD-capable plastic scintillator to standard liquid scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Woolf, Richard S., E-mail: richard.woolf@nrl.navy.mil [High Energy Space Environment Branch, Space Science Division, U. S. Naval Research Laboratory, 4555 Overlook Ave., SW, Washington, DC 20375 (United States); Hutcheson, Anthony L., E-mail: anthony.hutcheson@nrl.navy.mil [High Energy Space Environment Branch, Space Science Division, U. S. Naval Research Laboratory, 4555 Overlook Ave., SW, Washington, DC 20375 (United States); Gwon, Chul, E-mail: chul.gwon@nrl.navy.mil [High Energy Space Environment Branch, Space Science Division, U. S. Naval Research Laboratory, 4555 Overlook Ave., SW, Washington, DC 20375 (United States); Phlips, Bernard F., E-mail: bernard.phlips@nrl.navy.mil [High Energy Space Environment Branch, Space Science Division, U. S. Naval Research Laboratory, 4555 Overlook Ave., SW, Washington, DC 20375 (United States); Wulf, Eric A., E-mail: eric.wulf@nrl.navy.mil [High Energy Space Environment Branch, Space Science Division, U. S. Naval Research Laboratory, 4555 Overlook Ave., SW, Washington, DC 20375 (United States)

    2015-06-01

    This work discusses a test campaign to characterize the response of the recently developed plastic scintillator with pulse shape discrimination (PSD) capabilities (EJ-299-33). PSD is a property exhibited by certain types of scintillating material in which incident stimuli (fast neutrons or γ rays) can be separated by exploiting differences in the scintillation light pulse tail. Detector geometries used were: a 10 cm×10 cm×10 cm cube and a 10-cm diameter×10-cm long cylinder. EJ-301 and EJ-309 liquid scintillators with well-known responses were also tested. The work was conducted at the University of Massachusetts Lowell Van De Graaff accelerator. The facility accelerated protons on a thin Li target to yield quasi-monoenergetic neutrons from the {sup 7}Li(p,n){sup 7}Be reaction (Q-value: –1.644 MeV). Collimated fast neutrons were obtained by placing detectors behind a neutron spectrometer. Rotating the spectrometer, and thus changing the neutron energy, allowed us to achieve 0.5–3.2 MeV neutrons in 200–300 keV steps. Data were acquired through a flash analog-to-digital converter (ADC) capable of performing digital PSD measurements. By using the PSD technique to separate the neutron events from unwanted γ background, we constructed a pulse height spectrum at each energy. Obtaining a relationship of the relative light output versus energy allowed us to construct the response function for the EJ-299-33 and liquid scintillator. The EJ-299-33 response in terms of electron equivalent energy (E{sub e.e.}) vs. proton equivalent energy (E{sub p.e.}), how it compared with the standard xylene-based EJ-301 (or, NE-213/BC-501 A equivalent) and EJ-309 liquid scintillator response, and how the EJ-301 and EJ-309 compared, are presented. We find that the EJ-299-33 demonstrated a lower light output by up to 40% for <1.0 MeV neutrons; and ranging between a 5–35% reduction for 2.5–3.0 MeV neutrons compared to the EJ-301/309, depending on the scintillator and geometry

  16. Current trends in scintillator detectors and materials

    CERN Document Server

    Moses, W W

    2002-01-01

    The last decade has seen a renaissance in inorganic scintillator development for gamma ray detection. Lead tungstate (PbWO sub 4) has been developed for high-energy physics experiments, and possesses exceptionally high density and radiation hardness, albeit with low luminous efficiency. Lutetium orthosilicate or LSO (Lu sub 2 SiO sub 5 :Ce) possesses a unique combination of high luminous efficiency, high density, and reasonably short decay time, and is now incorporated in commercial positron emission tomography cameras. There have been advances in understanding the fundamental mechanisms that limit energy resolution, and several recently discovered materials (such as LaBr sub 3 :Ce) possess energy resolution that approaches that of direct solid state detectors. Finally, there are indications that a neglected class of scintillator materials that exhibit near band-edge fluorescence could provide scintillators with sub-nanosecond decay times and high luminescent efficiency.

  17. Study of timing characteristics of a 3 m long plastic scintillator counter using waveform digitizers

    CERN Document Server

    Blondel, A.; Dubreuil, A.; Khotyantsev, A.; Korzenev, A.; Maalmi, J.; Mefodev, A.; Mermod, P.; Noah, E.

    2016-01-01

    A plastic scintillator bar with dimensions 3 m x 2.5 cm x 11 cm was exposed to a focused muon beam to study its light yield and timing characteristics as a function of position and angle of incidence. The scintillating light was read out at both ends by photomultiplier tubes whose pulse shapes were recorded by waveform digitizers. Results obtained with the WAVECATCHER and SAMPIC digitizers are analyzed and compared. A comprehensive discussion of the various factors affecting the timing resolution is presented. Prospects for applications of plastic scintillator technology in large-scale particle physics detectors with timing resolution around 100 ps are provided in light of the results.

  18. Systematic evaluation of photodetector performance for plastic scintillation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Boivin, Jonathan, E-mail: jonathan.boivin.1@ulaval.ca; Beaulieu, Luc [Département de Physique, de Génie physique et d’Optique, et Centre de recherche sur le cancer, Université Laval, Québec, Québec G1V 0A6, Canada and Département de Radio-Oncologie et Axe oncologie du Centre de recherche du CHU de Québec, CHU de Québec, Québec, Québec G1R 2J6 (Canada); Beddar, Sam [Department of Radiation Physics, University of Texas, MD Anderson Cancer Center, Houston, Texas 77030 (United States); Guillemette, Maxime [Département de Physique, de Génie physique et d’Optique, Université Laval, Québec, Québec G1V 0A6, Canada and Institut Universitaire de Cardiologie et de Pneumologie de Québec, Québec, Québec G1V 4G5 (Canada)

    2015-11-15

    Purpose: The authors’ objective was to systematically assess the performance of seven photodetectors used in plastic scintillation dosimetry. The authors also propose some guidelines for selecting an appropriate detector for a specific application. Methods: The plastic scintillation detector (PSD) consisted of a 1-mm diameter, 10-mm long plastic scintillation fiber (BCF-60), which was optically coupled to a clear 10-m long optical fiber of the same diameter. A light-tight plastic sheath covered both fibers and the scintillator end was sealed. The clear fiber end was connected to one of the following photodetectors: two polychromatic cameras (one with an optical lens and one with a fiber optic taper replacing the lens), a monochromatic camera with an optical lens, a PIN photodiode, an avalanche photodiode (APD), or a photomultiplier tube (PMT). A commercially available W1 PSD was also included in the study, but it relied on its own fiber and scintillator. Each PSD was exposed to both low-energy beams (120, 180, and 220 kVp) from an orthovoltage unit and high-energy beams (6 and 23 MV) from a linear accelerator. Various dose rates were tested to identify the operating range and accuracy of each photodetector. Results: For all photodetectors, the relative uncertainty was less than 5% for dose rates higher than 3 mGy/s. The cameras allowed multiple probes to be used simultaneously, but they are less sensitive to low-light signals. The PIN, APD, and PMT had higher sensitivity, making them more suitable for low dose rate and out-of-field dose monitoring. The relative uncertainty of the PMT was less than 1% at the lowest dose rate achieved (0.10 mGy/s), suggesting that it was optimal for use in live dosimetry. Conclusions: For dose rates higher than 3 mGy/s, the PIN diode is the most effective photodetector in terms of performance/cost ratio. For lower dose rates, such as those seen in interventional radiology or high-gradient radiotherapy, PMTs are the optimal choice.

  19. Comparing the response of PSD-capable plastic scintillator to standard liquid scintillator

    Science.gov (United States)

    Woolf, Richard S.; Hutcheson, Anthony L.; Gwon, Chul; Phlips, Bernard F.; Wulf, Eric A.

    2015-06-01

    This work discusses a test campaign to characterize the response of the recently developed plastic scintillator with pulse shape discrimination (PSD) capabilities (EJ-299-33). PSD is a property exhibited by certain types of scintillating material in which incident stimuli (fast neutrons or γ rays) can be separated by exploiting differences in the scintillation light pulse tail. Detector geometries used were: a 10 cm×10 cm×10 cm cube and a 10-cm diameter×10-cm long cylinder. EJ-301 and EJ-309 liquid scintillators with well-known responses were also tested. The work was conducted at the University of Massachusetts Lowell Van De Graaff accelerator. The facility accelerated protons on a thin Li target to yield quasi-monoenergetic neutrons from the 7Li(p,n)7Be reaction (Q-value: -1.644 MeV). Collimated fast neutrons were obtained by placing detectors behind a neutron spectrometer. Rotating the spectrometer, and thus changing the neutron energy, allowed us to achieve 0.5-3.2 MeV neutrons in 200-300 keV steps. Data were acquired through a flash analog-to-digital converter (ADC) capable of performing digital PSD measurements. By using the PSD technique to separate the neutron events from unwanted γ background, we constructed a pulse height spectrum at each energy. Obtaining a relationship of the relative light output versus energy allowed us to construct the response function for the EJ-299-33 and liquid scintillator. The EJ-299-33 response in terms of electron equivalent energy (Ee.e.) vs. proton equivalent energy (Ep.e.), how it compared with the standard xylene-based EJ-301 (or, NE-213/BC-501 A equivalent) and EJ-309 liquid scintillator response, and how the EJ-301 and EJ-309 compared, are presented. We find that the EJ-299-33 demonstrated a lower light output by up to 40% for <1.0 MeV neutrons; and ranging between a 5-35% reduction for 2.5-3.0 MeV neutrons compared to the EJ-301/309, depending on the scintillator and geometry. Monte Carlo modeling techniques were

  20. A novel segmented-scintillator antineutrino detector

    Science.gov (United States)

    Abreu, Y.; Amhis, Y.; Arnold, L.; Ban, G.; Beaumont, W.; Bongrand, M.; Boursette, D.; Buhour, J. M.; Castle, B. C.; Clark, K.; Coupé, B.; Cucoanes, A. S.; Cussans, D.; De Roeck, A.; D'Hondt, J.; Durand, D.; Fallot, M.; Fresneau, S.; Ghys, L.; Giot, L.; Guillon, B.; Guilloux, G.; Ihantola, S.; Janssen, X.; Kalcheva, S.; Kalousis, L. N.; Koonen, E.; Labare, M.; Lehaut, G.; Mermans, J.; Michiels, I.; Moortgat, C.; Newbold, D.; Park, J.; Petridis, K.; Piñera, I.; Pommery, G.; Popescu, L.; Pronost, G.; Rademacker, J.; Reynolds, A.; Ryckbosch, D.; Ryder, N.; Saunders, D.; Shitov, Yu. A.; Schune, M.-H.; Scovell, P. R.; Simard, L.; Vacheret, A.; Van Dyck, S.; Van Mulders, P.; van Remortel, N.; Vercaemer, S.; Waldron, A.; Weber, A.; Yermia, F.

    2017-04-01

    The next generation of very-short-baseline reactor experiments will require compact detectors operating at surface level and close to a nuclear reactor. This paper presents a new detector concept based on a composite solid scintillator technology. The detector target uses cubes of polyvinyltoluene interleaved with 6LiF:ZnS(Ag) phosphor screens to detect the products of the inverse beta decay reaction. A multi-tonne detector system built from these individual cells can provide precise localisation of scintillation signals, making efficient use of the detector volume. Monte Carlo simulations indicate that a neutron capture efficiency of over 70 % is achievable with a sufficient number of 6LiF:ZnS(Ag) screens per cube and that an appropriate segmentation enables a measurement of the positron energy which is not limited by γ-ray leakage. First measurements of a single cell indicate that a very good neutron-gamma discrimination and high neutron detection efficiency can be obtained with adequate triggering techniques. The light yield from positron signals has been measured, showing that an energy resolution of 14%/√E(MeV) is achievable with high uniformity. A preliminary neutrino signal analysis has been developed, using selection criteria for pulse shape, energy, time structure and energy spatial distribution and showing that an antineutrino efficiency of 40% can be achieved. It also shows that the fine segmentation of the detector can be used to significantly decrease both correlated and accidental backgrounds.

  1. Scintillation Detectors in Experiments on Plasma Accelerators

    CERN Document Server

    Bystritsky, V M; Gerasimov, V V; Kublikov, R V; Nechaev, B A; Padalko, V M; Parzhitski, S S; Smirnov, V S; Wozniak, J

    2005-01-01

    The gating circuits for photomultipliers of scintillation detectors operating in powerful pulsed electromagnetic and nuclear radiation fields are investigated. PMTs with the jalousie-type dynode system and with the linear dynode system are considered. The basic gating circuits of the photomultipliers involving active and resistor high-voltage dividers are given. The results of the investigations are important for experiments in which it is necessary to discriminate in time the preceding background radiation and the process of interest.

  2. Fast timing with plastic scintillators for in-beam heavy-ion spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Hoischen, R., E-mail: robert.hoischen@nuclear.lu.se [Department of Physics, Lund University, SE-22100 Lund (Sweden); GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, D-64291 Darmstadt (Germany); Pietri, S. [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, D-64291 Darmstadt (Germany); Rudolph, D. [Department of Physics, Lund University, SE-22100 Lund (Sweden); Prokopowicz, W.; Schaffner, H. [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, D-64291 Darmstadt (Germany); Emde, S. [Lehrstuhl fuer Operations Management, Friedrich-Schiller-Universitaet Jena, D-07743 Jena (Germany); Golubev, P. [Department of Physics, Lund University, SE-22100 Lund (Sweden); Wendt, A. [Institut fuer Kernphysik, Universitaet zu Koeln, D-50937 Koeln (Germany); Kurz, N.; Wollersheim, H.J.; Gerl, J. [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, D-64291 Darmstadt (Germany)

    2011-10-21

    The design, R and D, and testing of a new plastic-scintillator detector for Time-of-Flight measurements with relativistic heavy-ion beams are presented. A design approach using 32 independent precise timing measurements of the same physical event is followed. This is different from the conventional scheme, which aims at two or four high-precision measurements. A circular, 27 cm in diameter, BC-420 plastic-scintillator sheet is read-out by 32 photomultiplier tubes in order to achieve an intrinsic detector resolution on the order of 10 ps root mean square.

  3. Buried plastic scintillator muon telescope (BATATA)

    Energy Technology Data Exchange (ETDEWEB)

    Alfaro, R. [Inst. de Fisica, Universidad Nacional Autonoma de Mexico, Mexico, D.F., C.P. 04510 (Mexico); De Donato, C.; D' Olivo, J.C.; Guzman, A.; Medina-Tanco, G. [Inst. de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Mexico, D.F., C.P. 04510 (Mexico); Moreno Barbosa, E. [Fac. de Ciencias Fisico Matematicas, Benemerita Universidad Autonoma de Puebla, Puebla (Mexico); Paic, G.; Patino Salazar, E. [Inst. de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Mexico, D.F., C.P. 04510 (Mexico); Salazar Ibarguen, H. [Fac. de Ciencias Fisico Matematicas, Benemerita Universidad Autonoma de Puebla, Puebla (Mexico); Sanchez, F.A., E-mail: federico.sanchez@nucleares.unam.m [Inst. de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Mexico, D.F., C.P. 04510 (Mexico); Supanitsky, A.D. [Inst. de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Mexico, D.F., C.P. 04510 (Mexico); Valdes-Galicia, J.F. [Inst. de Geofisica, Universidad Nacional Autonoma de Mexico, Mexico, D.F., C.P. 04510 (Mexico); Vargas Trevino, A.D.; Vergara Limon, S. [Fac. de Ciencias de la Electronica, Benemerita Universidad Autonoma de Puebla, Puebla (Mexico); Villasenor, L.M. [Inst. de Fisica y Matematicas, Universidad Michoacana de San Nicolas Hidalgo Morelia (Mexico); Observatorio Pierre Auger, Av. San Martin Norte 304 (5613) Malarguee, Prov. Mendoza (Argentina)

    2010-05-21

    Muon telescopes have multiple applications in the area of cosmic ray research. We are currently building such a detector with the objective of comparing the ground penetration of muon vs. electron-gamma signals originated in cosmic ray showers. The detector is composed by a set of three parallel dual-layer scintillator planes, buried at fixed depths ranging from 120 to 600g/cm{sup 2}. Each layer is 4m{sup 2} and is composed by 49 rectangular strips of 4cmx2m, oriented at a 90{sup 0} angle with respect to its companion layer, which gives an xy-coincidence pixel of 4x4cm{sup 2}. The scintillators are MINOS extruded polystyrene strips, with an embedded Bicron BC92 wavelength shifting (WLS) fibers, of 1.5 mm in diameter. Light is collected by Hamamatsu H7546B multi-anode PMTs of 64 pixels. The front-end (FE) electronics works in counting mode and signals are transmitted to the surface DAQ stage using low-voltage differential signaling (LVDS). Any strip signal above threshold opens a GPS-tagged 2{mu}s data collection window. Data, including signal and background, are acquired by a system of FPGA (Spartan 2E) boards and a single-board computer (TS7800).

  4. Buried plastic scintillator muon telescope (BATATA)

    Science.gov (United States)

    Alfaro, R.; de Donato, C.; D'Olivo, J. C.; Guzmán, A.; Medina-Tanco, G.; Moreno Barbosa, E.; Paic, G.; Patiño Salazar, E.; Salazar Ibarguen, H.; Sánchez, F. A.; Supanitsky, A. D.; Valdés-Galicia, J. F.; Vargas Treviño, A. D.; Vergara Limón, S.; Villaseñor, L. M.; Auger Collaboration

    2010-05-01

    Muon telescopes have multiple applications in the area of cosmic ray research. We are currently building such a detector with the objective of comparing the ground penetration of muon vs. electron-gamma signals originated in cosmic ray showers. The detector is composed by a set of three parallel dual-layer scintillator planes, buried at fixed depths ranging from 120 to 600g/cm2. Each layer is 4m2 and is composed by 49 rectangular strips of 4cm×2m, oriented at a 90∘ angle with respect to its companion layer, which gives an xy-coincidence pixel of 4×4cm2. The scintillators are MINOS extruded polystyrene strips, with an embedded Bicron BC92 wavelength shifting (WLS) fibers, of 1.5 mm in diameter. Light is collected by Hamamatsu H7546B multi-anode PMTs of 64 pixels. The front-end (FE) electronics works in counting mode and signals are transmitted to the surface DAQ stage using low-voltage differential signaling (LVDS). Any strip signal above threshold opens a GPS-tagged 2μs data collection window. Data, including signal and background, are acquired by a system of FPGA (Spartan 2E) boards and a single-board computer (TS7800).

  5. Central Tracking Detector Based on Scintillating Fibres

    CERN Multimedia

    2002-01-01

    Scintillating fibres form a reasonable compromise for central tracking detectors in terms of price, resolution, response time, occupancy and heat production. \\\\ \\\\ New fluorescents with large Stokes shifts have been produced, capable of working without wavelength shifters. Coherent multibundles have been developed to achieve high packing fractions. Small segments of tracker shell have been assembled and beam tests have confirmed expectations on spatial resolution. An opto-electronic delay line has been designed to delay the track patterns and enable coincidences with a first level trigger. Replacement of the conventional phosphor screen anode with a Si pixel chip is achieved. This tube is called ISPA-tube and has already been operated in beam tests with a scintillating fibres tracker. \\\\ \\\\ The aim of the proposal is to improve hit densities for small diameter fibres by increasing the fraction of trapped light, by reducing absorption and reflection losses, by reflecting light at the free fibre end, and by inc...

  6. Liquid scintillator composition optimization for use in ultra-high energy cosmic ray detector systems

    Science.gov (United States)

    Beznosko, Dmitriy; Batyrkhanov, Ayan; Iakovlev, Alexander; Yelshibekov, Khalykbek

    2017-06-01

    The Horizon-T (HT) detector system and the currently under R&D HT-KZ detector system are designed for the detection of Extensive Air Showers (EAS) with energies above ˜1016 eV (˜1017 eV for HT-KZ). The main challenges in both detector systems are the fast time resolutions needed for studying the temporary structure of EAS, and the extremely wide dynamic range needed to study the spatial distribution of charged particles in EAS disks. In order to detect the low-density of charged particles far from the EAS axis, a large-area detector is needed. Liquid scintillator with low cost would be a possible solution for such a detector, including the recently developed safe and low-cost water-based liquid scintillators. Liquid organic scintillators give a fast and high light yield (LY) for charged particle detection. It is similar to plastic scintillator in properties but is cost effective for large volumes. With liquid scintillator, one can create detection volumes that are symmetric and yet retain high LY detection. Different wavelength shifters affect the scintillation light by changing the output spectrum into the best detection region. Results of the latest studies of the components optimization in the liquid scintillator formulae are presented.

  7. Nonproportionality of Scintillator Detectors: Theory and Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Payne, Stephen; Cherepy, Nerine; Hull, Giulia; Valentine, John; Moses, William; Choong, Woon-Seng

    2009-08-17

    On the basis of nonproportionality data obtained for several scintillators, we have developed a theory to describe the carrier dynamics to fit the light yield versus electron energy. The theory of Onsager was adapted to explain how the carriers form excitons or sequentially arrive at the activators to promote the ion to an excited state, and the theory of Birks was employed to allow for exciton-exciton annihilation. We then developed a second theory to deduce the degradation in resolution that results from nonproportionality by evoking Landau fluctuations, which are essentially variations in the deposited energy density that occur as the high energy electron travels along its trajectory. In general there is good agreement with the data, in terms of fitting the nonproportionality curves and reproducing the literature values of nonproportionality's contribution to the scintillator resolution. With the resurgence of interest in developing scintillator detectors that have good energy resolution, an improved understanding of nonproportionality has become a crucial matter since it presents the fundamental limit to the achievable resolution. In order to hasten an improved understanding of scintillator nonproportionality, we have constructed an instrument referred to as SLYNCI (Scintillator Light Yield Nonproportionality Compton Instrument). This is a second-generation instrument to the original device developed by Valentine and coworkers, wherein several new principles of operation have served to increase the data rate by an order of magnitude as discussed in detail in References. In the present article, the focus is on a theory to describe the measured electron response, which is the light yield as a function of the electron energy. To do this, we account for transport of carriers and excitons, in terms of how they transfer their energy to the activators with competition from nonradiative decay pathways. This work builds on the original work of Murray and coworkers

  8. Reactor antineutrino monitoring with a plastic scintillator array as a new safeguards method

    CERN Document Server

    Oguri, S; Kato, Y; Nakata, R; Inoue, Y; Ito, C; Minowa, M

    2014-01-01

    We developed a segmented reactor-antineutrino detector made of plastic scintillators for application as a tool in nuclear safeguards inspection and performed mostly unmanned field operations at a commercial power plant reactor. At a position outside the reactor building, we measured the difference in reactor antineutrino flux above the ground when the reactor was active and inactive.

  9. Large-scale liquid scintillation detectors for solar neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Benziger, Jay B.; Calaprice, Frank P. [Princeton University Princeton, Princeton, NJ (United States)

    2016-04-15

    Large-scale liquid scintillation detectors are capable of providing spectral yields of the low energy solar neutrinos. These detectors require > 100 tons of liquid scintillator with high optical and radiopurity. In this paper requirements for low-energy neutrino detection by liquid scintillation are specified and the procedures to achieve low backgrounds in large-scale liquid scintillation detectors for solar neutrinos are reviewed. The designs, operations and achievements of Borexino, KamLAND and SNO+ in measuring the low-energy solar neutrino fluxes are reviewed. (orig.)

  10. Characteristics of plastic scintillators fabricated by a polymerization reaction

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Cheol Ho; Son, Jaebum; Kim, Tae Hoon; Kim, Yong Kyun [Dept. of Nuclear Engineering, Hanyang University, Seoul (Korea, Republic of)

    2017-04-15

    Three plastic scintillators of 4.5 cm diameter and 2.5-cm length were fabricated for comparison with commercial plastic scintillators using polymerization of the styrene monomer 2.5-diphenyloxazole (PPO) and 1,4-bis benzene (POPOP). Their maximum emission wavelengths were determined at 426.06 nm, 426.06 nm, and 425.00 nm with a standard error of 0.2% using a Varian spectrophotometer (Agilent, Santa Clara, CA, USA). Compton edge spectra were measured using three gamma ray sources [i.e., cesium 137 ({sup 137}Cs), sodium 22 ({sup 22}Na), and cobalt 60 ({sup 60}Co)]. Energy was calibrated by analyzing the Compton edge spectra. The fabricated scintillators possessed more than 99.7% energy linearity. Light output was comparable to that of the BC-408 scintillator (Saint-Gobain, Paris, France). The fabricated scintillators showed a light output of approximately 59–64% of that of the BC-408 scintillator.

  11. Optimization of plastic scintillator thicknesses for online beta/gamma detection

    Directory of Open Access Journals (Sweden)

    Pourtangestani K.

    2012-04-01

    Full Text Available For efficient beta detection in a mixed beta gamma field, Monte Carlo simulation models have been built to optimize the thickness of a plastic scintillator, used in a whole body monitor. The simulation has been performed using the MCNP/X code for different thicknesses of plastic scintillator from 150 μm to 600 μm. The relationship between the thickness of the scintillator and the efficiency of the detector has been analyzed. For 150 μm thickness, an experimental investigation has been conducted with different beta sources at different positions on the scintillator and the counting efficiency of the unit has been measured. Evaluated data along with experimental ones have been discussed. A thickness of 300 μm to 500 μm has been found to be the optimum thickness for high efficiency beta detection in the presence of low energy gamma-rays.

  12. Study on Signal Processing Circuit Based on Scintillation Detector

    Institute of Scientific and Technical Information of China (English)

    YAO; Yong-gang; DENG; Chang-ming; LI; Jian-wei; XIAO; Cai-jin; ZHANG; Gui-ying; WANG; Ping-sheng; WANG; Xing-hua; JIN; Xiang-chun; HUA; Long; YUAN; Guo-jun; NI; Bang-fa

    2013-01-01

    Compared with silicon semiconductor detector,higher energy resolution and together with the high detection efficiency,big sensitive volume,good adaptability to environment and high sensitivityespecially in nature background environment are the characteristics of scintillation detector.The most widely applied scintillator includes inorganic crystals,of which sodium iodide is the favorite and

  13. TOF-PET detector concept based on organic scintillators

    CERN Document Server

    Moskal, P; Białas, P; Ciszewska, M; Czerwiński, E; Heczko, A; Kajetanowicz, M; Kapłon, Ł; Kochanowski, A; Konopka-Cupiał, G; Korcyl, G; Krzemień, W; Łojek, K; Majewski, J; Migdał, W; Molenda, M; Niedźwiecki, Sz; Pałka, M; Rudy, Z; Salabura, P; Silarski, M; Słomski, A; Smyrski, J; Zdebik, J; Zieliński, M

    2013-01-01

    In this contribution we present a new concept of the large acceptance detector systems based on organic scintillators which may allow for simultaneous diagnostic of large fraction of the human body. Novelty of the concept lies in employing large blocks of polymer scintillators instead of crystals as detectors of annihilation quanta, and in using predominantly the timing of signals instead of their amplitudes.

  14. X-ray imaging and detection using plastic scintillating fibers

    CERN Document Server

    Ikhlef, A; Beddar, A S

    2000-01-01

    This paper discusses the application of plastic scintillating fiber array in X-ray imaging with low-energy radiation. This array is coupled to a multichannel intensified photocathode and then to a CCD detector via a fiber optics taper. The length of the fiber array is experimentally optimized for the radiation used. We found here that the length of the fibers (interaction medium) does not contribute too much in the degradation of the spatial resolution under 10 keV irradiation along the axis of the fiber array. Modulation Transfer Function (MTF) measurements of the PSF array are compared to the optics MTF of the imaging system (without the sample) and that cross-talk in the fiber array is found to be negligible for a fiber array thickness of 20 mm.

  15. Mixture quantification using PLS in plastic scintillation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Bagan, H.; Tarancon, A.; Rauret, G. [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 647, E-08028 Barcelona (Spain); Garcia, J.F., E-mail: jfgarcia@ub.ed [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 647, E-08028 Barcelona (Spain)

    2011-06-15

    This article reports the capability of plastic scintillation (PS) combined with multivariate calibration (Partial least squares; PLS) to detect and quantify alpha and beta emitters in mixtures. While several attempts have been made with this purpose in mind using liquid scintillation (LS), no attempt was done using PS that has the great advantage of not producing mixed waste after the measurements are performed. Following this objective, ternary mixtures of alpha and beta emitters ({sup 241}Am, {sup 137}Cs and {sup 90}Sr/{sup 90}Y) have been quantified. Procedure optimisation has evaluated the use of the net spectra or the sample spectra, the inclusion of different spectra obtained at different values of the Pulse Shape Analysis parameter and the application of the PLS1 or PLS2 algorithms. The conclusions show that the use of PS+PLS2 applied to the sample spectra, without the use of any pulse shape discrimination, allows quantification of the activities with relative errors less than 10% in most of the cases. This procedure not only allows quantification of mixtures but also reduces measurement time (no blanks are required) and the application of this procedure does not require detectors that include the pulse shape analysis parameter.

  16. Fundamental Limits of Scintillation Detector Timing Precision

    Science.gov (United States)

    Derenzo, Stephen E.; Choong, Woon-Seng; Moses, William W.

    2014-01-01

    In this paper we review the primary factors that affect the timing precision of a scintillation detector. Monte Carlo calculations were performed to explore the dependence of the timing precision on the number of photoelectrons, the scintillator decay and rise times, the depth of interaction uncertainty, the time dispersion of the optical photons (modeled as an exponential decay), the photodetector rise time and transit time jitter, the leading-edge trigger level, and electronic noise. The Monte Carlo code was used to estimate the practical limits on the timing precision for an energy deposition of 511 keV in 3 mm × 3 mm × 30 mm Lu2SiO5:Ce and LaBr3:Ce crystals. The calculated timing precisions are consistent with the best experimental literature values. We then calculated the timing precision for 820 cases that sampled scintillator rise times from 0 to 1.0 ns, photon dispersion times from 0 to 0.2 ns, photodetector time jitters from 0 to 0.5 ns fwhm, and A from 10 to 10,000 photoelectrons per ns decay time. Since the timing precision R was found to depend on A−1/2 more than any other factor, we tabulated the parameter B, where R = BA−1/2. An empirical analytical formula was found that fit the tabulated values of B with an rms deviation of 2.2% of the value of B. The theoretical lower bound of the timing precision was calculated for the example of 0.5 ns rise time, 0.1 ns photon dispersion, and 0.2 ns fwhm photodetector time jitter. The lower bound was at most 15% lower than leading-edge timing discrimination for A from 10 to 10,000 photoelectrons/ns. A timing precision of 8 ps fwhm should be possible for an energy deposition of 511 keV using currently available photodetectors if a theoretically possible scintillator were developed that could produce 10,000 photoelectrons/ns. PMID:24874216

  17. B-Loaded Plastic Scintillator on the Base of Polystyrene

    CERN Document Server

    Brudanin, V B; Nemchenok, I B; Smolnikov, A A

    2000-01-01

    A method to produce polystyrene-based plastic scintillators with boron concentration from 0.38 to 5.0% of boron have been developed. o-Carborane was used as B-containing additive. The results of investigations of the optical, spectral and scintillation characteristics are presented and discussed. It is shown that 5% B-loaded scintillator has a light output as much as 70% relative to the unloaded one. High efficiency for thermal neutron registration achieved for produced samples makes it possible to use such scintillators in complex neutron high sensitive spectrometers. Measured level of radioactive contamination in this scintillation materials is good enough for using the B-loaded scintillators in the proposed large scale neutrino experiments.

  18. Transparent plastic scintillators for neutron detection based on lithium salicylate

    Energy Technology Data Exchange (ETDEWEB)

    Mabe, Andrew N., E-mail: mabe2@llnl.gov; Glenn, Andrew M.; Carman, M. Leslie; Zaitseva, Natalia P.; Payne, Stephen A.

    2016-01-11

    Transparent plastic scintillators with pulse shape discrimination containing {sup 6}Li salicylate have been synthesized by bulk polymerization with a maximum {sup 6}Li loading of 0.40 wt%. Photoluminescence and scintillation responses to gamma-rays and neutrons are reported herein. Plastics containing {sup 6}Li salicylate exhibit higher light yields and permit a higher loading of {sup 6}Li as compared to previously reported plastics based on lithium 3-phenylsalicylate. However, pulse shape discrimination performance is reduced in lithium salicylate plastics due to the requirement of adding more nonaromatic monomers to the polymer matrix as compared to those based on lithium 3-phenylsalicylate. Reduction in light yield and pulse shape discrimination performance in lithium-loaded plastics as compared to pulse shape discrimination plastics without lithium is interpreted in terms of energy transfer interference by the aromatic lithium salts. - Highlights: • Plastic scintillator with 0.4% {sup 6}Li loading is reported using lithium salicylate. • Influence of lithium salts on the scintillation mechanism is explored. • New lithium-loaded scintillator provides improved light yield and reduced cost.

  19. Comparison of Lithium Gadolinium Borate Crystal Shards in Scintillating and Nonscintillating Plastic Matrices

    CERN Document Server

    Kazkaz, Kareem; Pedretti, Marisa

    2011-01-01

    We present a method for detecting neutrons using scintillating lithium gadolinium borate crystal shards in a plastic matrix while maintaining high gamma rejection. We have procured two cylindrical detectors, 5"\\times5", containing 1% crystal by mass. Crystal shards have a typical dimension of 1 mm. One detector was made with scintillating plastic, and one with nonscintillating plastic. Pulse shape analysis was used to reject gamma ray backgrounds. The scintillating detector was measured to have an intrinsic fast fission neutron efficiency of 0.4% and a gamma sensitivity of less than 2.3 \\times 10-9, while the nonscintillating detector had a neutron efficiency of 0.7% and gamma sensitivity of (4.75\\pm3.94)\\times10-9. We determine that increasing the neutron detection efficiency by a factor of 2 will make the detector competitive with moderated 3He tubes, and we discuss several simple and straightforward methods for obtaining or surpassing such an improvement. We end with a discussion of possible applications, ...

  20. Scintillation characteristics of phosphich-detector for detection of beta- and gamma-radiations

    CERN Document Server

    Ananenko, A A; Gavrilyuk, V

    2002-01-01

    The results of the study on the influence of individual peculiarities of the compound scintillation detector structure on the value and stability of the light yield by the gamma- and beta-radiation combined registration are presented. The phosphich detector is manufactured from the sodium iodide monocrystal, activated by thallium, and the scintillation plastic on the polystyrol basis. The comparison of the experimental results with the mathematical modeling data revealed certain regularities of the process of forming the phosphich detector light signal. The recommendations are worked out by means whereof the following characteristics of the scintillation unit: the light yield and its stability, amplitude resolution and the peak-to-valley ratio by the gamma- and beta-radiation registration were improved

  1. Transparent plastic scintillators for neutron detection based on lithium salicylate

    Energy Technology Data Exchange (ETDEWEB)

    Mabe, Andrew N.; Glenn, Andrew M.; Carman, M. Leslie; Zaitseva, Natalia P.; Payne, Stephen A.

    2016-01-01

    Transparent plastic scintillators with pulse shape discrimination containing 6Li salicylate have been synthesized by bulk polymerization with a maximum 6Li loading of 0.40 wt%. Photoluminescence and scintillation responses to gamma-rays and neutrons are reported herein. Plastics containing 6Li salicylate exhibit higher light yields and permit a higher loading of 6Li as compared to previously reported plastics based on lithium 3-phenylsalicylate. However, pulse shape discrimination performance is reduced in lithium salicylate plastics due to the requirement of adding more nonaromatic monomers to the polymer matrix as compared to those based on lithium 3-phenylsalicylate. Reduction in light yield and pulse shape discrimination performance in lithium-loaded plastics as compared to pulse shape discrimination plastics without lithium is interpreted in terms of energy transfer interference by the aromatic lithium salts.

  2. Production of the Large-area Plastic Scintillator for Beta-ray Detection using Epoxy Resin

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Jong Soo; Choi, Yong Seok; Hong, Sang Bum; Seo, Bum Kyung; Moon, Jei Kwon; Choi, Jong Won [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    In this study, we prepared a plastic scintillator whose manufacturing process is simple and can be freely shaped. A thin plate of the plastic scintillator was manufactured using epoxy resin as a polymer. The plastic scintillator was made by mixing epoxy resin and organic scintillators under various conditions. The optimal mixture ratio to prepare the plastic scintillator was derived from the above results. Using the derived results, we made the large-area plastic scintillator which can quickly measure the contamination site and evaluated characteristics of the large-area plastic scintillator in the laboratory. A thin plate of a plastic scintillator with a simple preparation process can be freely shaped using epoxy resin and organic scintillators such as PPO and POPOP. PPO emits scintillation of light in the ultraviolet range, and POPOP is a wave shifter for moving the wavelength responsible for the PMT. The mixture ratio of PPO and POPOP was determined using their emission spectra. The optimal weight percentage of PPO and POPOP in an organic scintillator was determined to be 0.2 wt%:0.01 wt%. Based on the above results, the large-area plastic scintillator of the window size of a typical pancake-type αβ surface contamination counter was prepared. We want to evaluate the characteristics of the large-area plastic scintillator. However, there were the difficulties in evaluating characteristics of the large-area plastic scintillator. The cross-sectional area of the large-area plastic scintillator is significantly different to PMT.

  3. Improved Scintillator Materials For Compact Electron Antineutrino Detectors

    NARCIS (Netherlands)

    Dijkstra, Peter; Wortche, Heinrich J.; Browne, Wesley R.

    2012-01-01

    Recent developments provide new components holding the potential to improve the performance of liquid scintillation electron antineutrino detectors used as nuclear reactors monitors. Current systems raise issues regarding size, quantum efficiency, stability, and spatial resolution of the vertex dete

  4. Reactor Neutrino Experiments with a Large Liquid Scintillator Detector

    CERN Document Server

    Kopp, J F; Merle, A; Rolinec, M

    2007-01-01

    We discuss several new ideas for reactor neutrino oscillation experiments with a Large Liquid Scintillator Detector. We consider two different scenarios for a measurement of the small mixing angle $\\theta_{13}$ with a mobile $\\bar{\

  5. Final LDRD report : advanced plastic scintillators for neutron detection.

    Energy Technology Data Exchange (ETDEWEB)

    Vance, Andrew L.; Mascarenhas, Nicholas; O' Bryan, Greg; Mrowka, Stanley

    2010-09-01

    This report summarizes the results of a one-year, feasibility-scale LDRD project that was conducted with the goal of developing new plastic scintillators capable of pulse shape discrimination (PSD) for neutron detection. Copolymers composed of matrix materials such as poly(methyl methacrylate) (PMMA) and blocks containing trans-stilbene (tSB) as the scintillator component were prepared and tested for gamma/neutron response. Block copolymer synthesis utilizing tSBMA proved unsuccessful so random copolymers containing up to 30% tSB were prepared. These copolymers were found to function as scintillators upon exposure to gamma radiation; however, they did not exhibit PSD when exposed to a neutron source. This project, while falling short of its ultimate goal, demonstrated the possible utility of single-component, undoped plastics as scintillators for applications that do not require PSD.

  6. Luminosity measurement at ATLAS-Development, construction and test of scintillating fibre prototype detectors

    Energy Technology Data Exchange (ETDEWEB)

    Ask, S. [CERN, PH Department, Geneva (Switzerland); Barrillon, P. [Laboratoire d' Accelerateur Lineaire, Orsay (France); Braem, A. [CERN, PH Department, Geneva (Switzerland); Cheiklali, C. [Laboratoire d' Accelerateur Lineaire, Orsay (France); Efthymiopoulos, I. [CERN, PH Department, Geneva (Switzerland); Fournier, D. [Laboratoire d' Accelerateur Lineaire, Orsay (France); Taille, C. de la [Laboratoire d' Accelerateur Lineaire, Orsay (France); Di Girolamo, B. [CERN, PH Department, Geneva (Switzerland); Grafstrom, P. [CERN, PH Department, Geneva (Switzerland); Joram, C. [CERN, PH Department, Geneva (Switzerland)]. E-mail: christian.joram@cern.ch; Haguenauer, M. [Ecole Polytechnique, Palaiseau (France); Hedberg, V. [University of Lund (Sweden); Lavigne, B. [Laboratoire d' Accelerateur Lineaire, Orsay (France); Maio, A. [LIP - Laboratorio de Instrumentacao e Fisica Experimental de Particulas and CFNUL - Centro de Fisica Nuclear da Universidade de Lisboa, Lisbon (Portugal); Mapelli, A. [CERN, PH Department, Geneva (Switzerland); Mjoernmark, U. [University of Lund (Sweden); Puzo, P. [Laboratoire d' Accelerateur Lineaire, Orsay (France); Rijssenbeek, M. [Stony Brook University, New York (United States); Santos, J. [LIP - Laboratorio de Instrumentacao e Fisica Experimental de Particulas and CFNUL - Centro de Fisica Nuclear da Universidade de Lisboa, Lisbon (Portugal); Saraiva, J.G. [LIP - Laboratorio de Instrumentacao e Fisica Experimental de Particulas and CFNUL - Centro de Fisica Nuclear da Universidade de Lisboa, Lisbon (Portugal); Stenzel, H. [II. Physikalisches Institut, Justus-Liebig-Universitaet, Giessen (Germany); Thioye, M. [Stony Brook University, New York (United States); Valladolid, E. [CERN, PH Department, Geneva (Switzerland); Vorobel, V. [Faculty of Mathematics and Physics, Charles University in Prague (Czech Republic)

    2006-12-01

    We are reporting about a scintillating fibre tracking detector which is proposed for the precise determination of the absolute luminosity of the CERN LHC at interaction point 1 where the ATLAS experiment is located. The detector needs to track protons elastically scattered under {mu}rad angles in direct vicinity to the LHC beam. It is based on square shaped scintillating plastic fibres read out by multi-anode photomultiplier tubes and is housed in Roman Pots. We describe the design and construction of prototype detectors and the results of a beam test experiment at DESY. The excellent detector performance established in this test validates the detector design and supports the feasibility of the proposed challenging method of luminosity measurement.

  7. Luminosity Measurement at ATLAS Development, Construction and Test of Scintillating Fibre Prototype Detectors

    CERN Document Server

    Ask, S; Braem, André; Cheiklali, C; Efthymiopoulos, I; Fournier, D; de La Taille, C; Di Girolamo, B; Grafström, P; Joram, C; Haguenauer, Maurice; Hedberg, V; Lavigne, B; Maio, A; Mapelli, A; Mjörnmark, U; Puzo, P; Rijssenbeek, M; Santos, J; Saraiva, J G; Stenzel, H; Thioye, M; Valladolid, E; Vorobel, V

    2006-01-01

    We are reporting about a scintillating fibre tracking detector which is proposed for the precise determination of the absolute luminosity of the CERN LHC at interaction point 1 where the ATLAS experiment is located. The detector needs to track protons elastically scattered under $\\mu$rad angles in direct vicinity to the LHC beam. It is based on square shaped scintillating plastic fibres read out by multi-anode photomultiplier tubes and is housed in Roman Pots. We describe the design and construction of prototype detectors and the results of a beam test experiment at DESY. The excellent detector performance established in this test validates the detector design and supports the feasibility of the proposed challenging method of luminosity measurement.

  8. Spatial response characterization of He-4 scintillation detectors

    Science.gov (United States)

    Kelley, Ryan P.; Steinberg, Noah; Murer, David; Ray, Heather; Jordan, Kelly A.

    2015-09-01

    The spatial response of pressurized helium-4 fast neutron scintillation detectors is characterized using collimated neutron source measurements and MCNPX-PoliMi simulations. A method for localizing the position of each detected event is also demonstrated using the two-sided photomultiplier readout. Results show that the position of particle interaction along the axis of the active volume has a measurable effect on the scintillation light response of the detector. An algorithm is presented that uses the probability distribution of relative interaction positions to perform source localization, further demonstrating the applicability of these detectors as tools for the detector of hidden shielded nuclear material.

  9. Monte-Carlo simulation for determining SNR and DQE of linear array plastic scintillating fiber

    Institute of Scientific and Technical Information of China (English)

    Mohammad Mehdi NASSERI; MA Qing-Li; YIN Ze-Jie; WU Xiao-Yi

    2004-01-01

    Fundamental characteristics of the plastic-scintillating fiber (PSF) for wide energy range of electromagnetic radiation (X & γ) have been studied to evaluate possibility of using the PSF as an imaging detector for industrial purposes. Monte-Carlo simulation program (GEANT4.5.1, 2003) was used to generate the data. In order to evaluate image quality of the detector, fiber array was irradiated under various energy and fluxes. Signal to noise ratio (SNR)as well as detector quantum efficiency (DQE) were obtained.

  10. Determination of spatial resolution of plastic scintillation fiber array with a simple method

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The spatial resolution of a position sensitive gamma-ray detector configuration based on plastic scintillation fiber array was measured using a Monte Carlo simulation method. Both point spread function and modulation transfer function (MTF) were presented. The factors that influence the spatial resolution were also discussed. The results of the simulation showed that the intrinsic spatial resolution was consistent with the size of the physical pixels and a few centimeters spatial resolution could be obtained under certain circumstances.

  11. Characteristics of Plastic Scintillators Fabricated by a Polymerization Reaction

    Directory of Open Access Journals (Sweden)

    Cheol Ho Lee

    2017-04-01

    Full Text Available Three plastic scintillators of 4.5 cm diameter and 2.5-cm length were fabricated for comparison with commercial plastic scintillators using polymerization of the styrene monomer 2.5-diphenyloxazole (PPO and 1,4-bis benzene (POPOP. Their maximum emission wavelengths were determined at 426.06 nm, 426.06 nm, and 425.00 nm with a standard error of 0.2% using a Varian spectrophotometer (Agilent, Santa Clara, CA, USA. Compton edge spectra were measured using three gamma ray sources [i.e., cesium 137 (137Cs, sodium 22 (22Na, and cobalt 60 (60Co]. Energy was calibrated by analyzing the Compton edge spectra. The fabricated scintillators possessed more than 99.7% energy linearity. Light output was comparable to that of the BC-408 scintillator (Saint-Gobain, Paris, France. The fabricated scintillators showed a light output of approximately 59–64% of that of the BC-408 scintillator.

  12. Active Well Counting Using New PSD Plastic Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Hausladen, Paul [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Newby, Jason [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); McElroy, Robert Dennis [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-11-01

    This report presents results and analysis from a series of proof-of-concept measurements to assess the suitability of segmented detectors constructed from Eljen EJ-299-34 PSD-plastic scintillator with pulse-shape discrimination capability for the purposes of quantifying uranium via active neutron coincidence counting. Present quantification of bulk uranium materials for international safeguards and domestic materials control and accounting relies on active neutron coincidence counting systems, such as the Active Well Coincidence Counter (AWCC) and the Uranium Neutron Coincidence Collar (UNCL), that use moderated He-3 proportional counters along with necessarily low-intensity 241Am(Li) neutron sources. Scintillation-based fast-neutron detectors are a potentially superior technology to the existing AWCC and UNCL designs due to their spectroscopic capability and their inherently short neutron coincidence times that largely eliminate random coincidences and enable interrogation by stronger sources. One of the past impediments to the investigation and adoption of scintillation counters for the purpose of quantifying bulk uranium was the commercial availability of scintillators having the necessary neutron-gamma pulse-shape discrimination properties only as flammable liquids. Recently, Eljen EJ-299-34 PSD-plastic scintillator became commercially available. The present work is the first assessment of an array of PSD-plastic detectors for the purposes of quantifying bulk uranium. The detector panel used in the present work was originally built as the focal plane for a fast-neutron imager, but it was repurposed for the present investigation by construction of a stand to support the inner well of an AWCC immediately in front of the detector panel. The detector panel and data acquisition of this system are particularly well suited for performing active-well fast-neutron counting of LEU and HEU samples because the active detector volume is solid, the 241Am(Li) interrogating

  13. Plastic scintillators for positron emission tomography obtained by the bulk polymerization method

    CERN Document Server

    Kapłon, Łukasz; Molenda, Marcin; Moskal, Paweł; Wieczorek, Anna; Bednarski, Tomasz; Białas, Piotr; Czerwiński, Eryk; Korcyl, Grzegorz; Kowal, Jakub; Kowalski, Paweł; Kozik, Tomasz; Krzemień, Wojciech; Niedźwiecki, Szymon; Pałka, Marek; Pawlik, Monika; Raczyński, Lech; Rudy, Zbigniew; Salabura, Piotr; Gupta-Sharma, Neha; Silarski, Michał; Słomski, Artur; Smyrski, Jerzy; Strzelecki, Adam; Wiślicki, Wojciech; Zieliński, Marcin; Zoń, Natalia

    2015-01-01

    This paper describes three methods regarding the production of plastic scintillators. One method appears to be suitable for the manufacturing of plastic scintillator, revealing properties which fulfill the requirements of novel positron emission tomography scanners based on plastic scintillators. The key parameters of the manufacturing process are determined and discussed.

  14. Time-based position estimation in monolithic scintillator detectors

    NARCIS (Netherlands)

    Tabacchini, V.; Borghi, G.; Schaart, D.R.

    2015-01-01

    Gamma-ray detectors based on bright monolithic scintillation crystals coupled to pixelated photodetectors are currently being considered for several applications in the medical imaging field. In a typical monolithic detector, both the light intensity and the time of arrival of the earliest

  15. Time-based position estimation in monolithic scintillator detectors

    NARCIS (Netherlands)

    Tabacchini, V.; Borghi, G.; Schaart, D.R.

    2015-01-01

    Gamma-ray detectors based on bright monolithic scintillation crystals coupled to pixelated photodetectors are currently being considered for several applications in the medical imaging field. In a typical monolithic detector, both the light intensity and the time of arrival of the earliest scintilla

  16. Time-based position estimation in monolithic scintillator detectors

    NARCIS (Netherlands)

    Tabacchini, V.; Borghi, G.; Schaart, D.R.

    2015-01-01

    Gamma-ray detectors based on bright monolithic scintillation crystals coupled to pixelated photodetectors are currently being considered for several applications in the medical imaging field. In a typical monolithic detector, both the light intensity and the time of arrival of the earliest scintilla

  17. Plastic neutron detectors.

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Tiffany M.S; King, Michael J.; Doty, F. Patrick

    2008-12-01

    This work demonstrated the feasibility and limitations of semiconducting {pi}-conjugated organic polymers for fast neutron detection via n-p elastic scattering. Charge collection in conjugated polymers in the family of substituted poly(p-phenylene vinylene)s (PPV) was evaluated using band-edge laser and proton beam ionization. These semiconducting materials can have high H/C ratio, wide bandgap, high resistivity and high dielectric strength, allowing high field operation with low leakage current and capacitance noise. The materials can also be solution cast, allowing possible low-cost radiation detector fabrication and scale-up. However, improvements in charge collection efficiency are necessary in order to achieve single particle detection with a reasonable sensitivity. The work examined processing variables, additives and environmental effects. Proton beam exposure was used to verify particle sensitivity and radiation hardness to a total exposure of approximately 1 MRAD. Conductivity exhibited sensitivity to temperature and humidity. The effects of molecular ordering were investigated in stretched films, and FTIR was used to quantify the order in films using the Hermans orientation function. The photoconductive response approximately doubled for stretch-aligned films with the stretch direction parallel to the electric field direction, when compared to as-cast films. The response was decreased when the stretch direction was orthogonal to the electric field. Stretch-aligned films also exhibited a significant sensitivity to the polarization of the laser excitation, whereas drop-cast films showed none, indicating improved mobility along the backbone, but poor {pi}-overlap in the orthogonal direction. Drop-cast composites of PPV with substituted fullerenes showed approximately a two order of magnitude increase in photoresponse, nearly independent of nanoparticle concentration. Interestingly, stretch-aligned composite films showed a substantial decrease in

  18. Preparation and characterization of a novel UV-curable plastic scintillator

    Science.gov (United States)

    Zhu, Jun; Ding, Yunyu; Zhu, Jiayi; Qi, Di; Su, Ming; Xu, Yewei; Bi, Yutie; Lin, Runxiong; Zhang, Lin

    2016-05-01

    A novel UV-curable plastic scintillator was first prepared by using the technology of photosensitivity rapid prototyping. It used the copolymer of 621A-80, TPGDA and styrene as the matrix doped with PPO and POPOP. Its fluorescence spectra displayed a maximum emission wavelength at 428 nm. The light yield of the plastic scintillator was approximately 7.1% of anthracene on the basis of a comparison with the commercially available scintillator (ST-401). The as-prepared plastic scintillator also displayed a fast scintillation decay. Its decay time is 2.6 ns approximately. Importantly, through the technology of photosensitivity rapid prototyping, the plastic scintillator could be prepared in a short period of time at low temperature. What's more, this preparation method provides the possibility of combining the plastic scintillator with 3D printing technology, and then the applications of the plastic scintillator may be expanded greatly.

  19. Preparation and characterization of a novel UV-curable plastic scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Jun [Engineering Research Center of High Performance Polymer and Molding Technology, Ministry of Education, Qingdao University of Science and Technology, Qingdao 266042 (China); Joint Laboratory for Extreme Conditions Matter Properties, Southwest University of Science and Technology and Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621010 (China); Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Ding, Yunyu [Engineering Research Center of High Performance Polymer and Molding Technology, Ministry of Education, Qingdao University of Science and Technology, Qingdao 266042 (China); Zhu, Jiayi [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Qi, Di [Engineering Research Center of High Performance Polymer and Molding Technology, Ministry of Education, Qingdao University of Science and Technology, Qingdao 266042 (China); Su, Ming [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Xu, Yewei; Bi, Yutie [Joint Laboratory for Extreme Conditions Matter Properties, Southwest University of Science and Technology and Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621010 (China); Lin, Runxiong, E-mail: qdlrx@qust.edu.cn [Engineering Research Center of High Performance Polymer and Molding Technology, Ministry of Education, Qingdao University of Science and Technology, Qingdao 266042 (China); Zhang, Lin, E-mail: zhlmy@sina.com [Joint Laboratory for Extreme Conditions Matter Properties, Southwest University of Science and Technology and Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621010 (China); Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China)

    2016-05-01

    A novel UV-curable plastic scintillator was first prepared by using the technology of photosensitivity rapid prototyping. It used the copolymer of 621A-80, TPGDA and styrene as the matrix doped with PPO and POPOP. Its fluorescence spectra displayed a maximum emission wavelength at 428 nm. The light yield of the plastic scintillator was approximately 7.1% of anthracene on the basis of a comparison with the commercially available scintillator (ST-401). The as-prepared plastic scintillator also displayed a fast scintillation decay. Its decay time is 2.6 ns approximately. Importantly, through the technology of photosensitivity rapid prototyping, the plastic scintillator could be prepared in a short period of time at low temperature. What's more, this preparation method provides the possibility of combining the plastic scintillator with 3D printing technology, and then the applications of the plastic scintillator may be expanded greatly.

  20. Monte Carlo calculation of radiation energy absorbed in plastic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Mainardi, R.T.; Bonzi, E.V. [Universidad Nacional de Cordoba (Argentina). Facultad de Matematica, Astronomia y Fisica

    1995-05-01

    Monte Carlo calculations of the rate of absorbed energy from a photon beam were carried out to compare the response of commercial plastic scintillators with that of air in the energy region below 1 MeV. We have found that for photon energies above 100 keV, the response of different kinds of plastics is proportional to that of air, while below this value of energy, we have obtained differences between the responses of plastics and air. In a literature search, we have also found discrepancies with other authors as well as among them. In this paper, we investigate the possibilities of eliminating these differences and explaining discrepancies. We found that doping a plastic scintillator with silicon makes the composite materials behave like air from 2 keV up to 600 keV, making the ratio of absorbed energy constant. This energy region is of interest in radiology and surface radiotherapy and we conclude that a plastic scintillator with truly air-equivalent behavior is of importance to carry out more precise dosimetry. Other elements such as fluorine and magnesium were also considered, but silicon was found to be more appropriate due to its greater atomic number and its interchangeability with carbon in hydrocarbon molecules. (author).

  1. Optimization of a coincidence system using plastic scintillators in 4pi geometry.

    Science.gov (United States)

    Dias, M S; Piuvezam-Filho, H; Koskinas, M F

    2008-01-01

    Improvements recently developed at the Nuclear Metrology Laboratory of IPEN-CNEN/SP in São Paulo were performed in order to increase the detector efficiency of a 4pibeta-gamma coincidence primary system using plastic scintillators in 4pi geometry. Measurements were undertaken and compared to the original system and Monte Carlo simulations of the extrapolation curves were calculated for this new system and compared to experimental results. For this purpose, the code Penelope was applied for calculating response functions for each detector and the code Esquema, developed at LMN, was used for simulating the decay scheme processes.

  2. First approach to radionuclide mixtures quantification by using plastic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Tarancon, A. [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 647, E-08028 Barcelona (Spain); Garcia, J.F. [Departament de Pintura, Universitat de Barcelona, Pau Gargallo 4, E-08028 Barcelona (Spain)]. E-mail: jfgarcia@ub.edu; Rauret, G. [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 647, E-08028 Barcelona (Spain)

    2007-05-08

    Recent studies have evaluated the capability of plastic scintillation (PS) as an alternative to liquid scintillation (LS) in radionuclide activity determination without mixed waste production. In order to complete the comparison, we now assess the extent to which PS can be used to quantify mixtures of radionuclides and the influence of the diameter of the plastic scintillation beads in detection efficiency. The results show that the detection efficiency decreases and the spectrum shrink to lower energies when the size of the plastic scintillation beads increases, and that the lower the energy of the beta particle, the greater the variation takes place. Similar behaviour has been observed for beta-gamma and alpha emitters. Two scenarios for the quantification of mixtures are considered, one including two radionuclides ({sup 14}C and {sup 60}Co) whose spectra do not overlap significantly, and the other including two radionuclides ({sup 137}Cs and {sup 90}Sr/{sup 90}Y), where the spectra of one the isotopes is totally overlapped by the other The calculation has been performed by using the conventional window selection procedure and a new approach in which the selected windows correspond to those with lower quantification errors. Relative errors obtained using the proposed approach (less than 10%) are lower than those of the conventional procedure, even when a radionuclide is completely overlapped, except for those samples with extreme activity ratios that were not included in the window optimization process.

  3. Novel Scintillation Detectors for Prompt Fission γ-Ray Measurements

    Science.gov (United States)

    Billnert, R.; Andreotti, E.; Hambsch, F.-J.; Hult, M.; Karlsson, J.; Marissens, G.; Oberstedt, A.; Oberstedt, S.

    In this work we present first results from measurements of prompt fission γ-rays from the spontaneous fission in 252Cf. New and accurate data on corresponding γ-rays from the reactions 235U(nth,f) and 239Pu(nth,f) are highly demanded for the modeling of new Generation-IV nuclear reactor systems. For these experiments we employed scintillation detectors made out of new materials (LaBr3, LaCl3 and CeBr3), whose properties were necessary to know in order to obtain reliable results. Hence, we have characterized these detectors. In all the important properties these detectors outshine sodium-iodine detectors that where used in the 1970s, when the existing data had been acquired. Our finding is that the new generation of scintillation detectors is indeed promising, as far as an improved precision of the demanded data is concerned.

  4. Time-resolved plastic scintillator dosimetry in a dynamic thorax phantom

    DEFF Research Database (Denmark)

    Sibolt, Patrik; Andersen, Claus E.; Ottosson, Wiviann

    2017-01-01

    Motion managed and dynamic radiotherapy of lung cancer patients is increasingly complex and subject to challenges related to respiratory motion and heterogeneous tissue densities. This puts high demands on methods for quality assurance and especially time-resolved dose verification of the treatment...... in a lung. The phantom motion was controlled by a script in-house developed using LabVIEW (National Instruments) and synchronized with the in-house developed ME40 scintillator dosimetry system (DTU Nutech). The dose in the center of the tumor was measured, using a BCF-60 plastic scintillator detector (Saint......-Gobain Ceramics & Plastics Inc.), during dynamic 6 MV half-arc treatments on a TrueBeam linear accelerator (Varian Medical Systems). Deviations of ∼2% from the corresponding dose calculated by the treatment planning system (TPS) were detected. The results emphasize the shortcomings of commercial TPSs to handle...

  5. Brightness and uniformity measurements of plastic scintillator tiles at the CERN H2 test beam arXiv

    CERN Document Server

    Chatrchyan, S.; Tumasyan, A.; Litomin, A.; Mossolov, V.; Shumeiko, N.; Van De Klundert, M.; Van Haevermaet, H.; Van Mechelen, P.; Van Spilbeeck, A.; Alves, G.A.; Aldá Júnior, W.L.; Hensel, C.; Carvalho, W.; Chinellato, J.; De Oliveira Martins, C.; Matos Figueiredo, D.; Mora Herrera, C.; Nogima, H.; Prado Da Silva, W.L.; Tonelli Manganote, E.J.; Vilela Pereira, A.; Finger, M.; , M.Finger Jr.; Kveton, A.; Tomsa, J.; Adamov, G.; Tsamalaidze, Z.; Behrens, U.; Borras, K.; Campbell, A.; Costanza, F.; Gunnellini, P.; Lobanov, A.; Melzer-Pellmann, I.-A.; Muhl, C.; Roland, B.; Sahin, M.; Saxena, P.; Hegde, V.; Kothekar, K.; Pandey, S.; Sharma, S.; Beri, S.B.; Bhawandeep, B.; Chawla, R.; Kalsi, A.; Kaur, A.; Kaur, M.; Walia, G.; Bhattacharya, S.; Ghosh, S.; Nandan, S.; Purohit, A.; Sharan, M.; Banerjee, S.; Bhattacharya, S.; Chatterjee, S.; Das, P.; Guchait, M.; Jain, S.; Kumar, S.; Maity, M.; Majumder, G.; Mazumdar, K.; Patil, M.; Sarkar, T.; Juodagalvis, A.; Afanasiev, S.; Bunin, P.; Ershov, Y.; Golutvin, I.; Malakhov, A.; Moisenz, P.; Smirnov, V.; Zarubin, A.; Chadeeva, M.; Chistov, R.; Danilov, M.; Popova, E.; Rusinov, V.; Andreev, Yu.; Dermenev, A.; Karneyeu, A.; Krasnikov, N.; Tlisov, D.; Toropin, A.; Epshteyn, V.; Gavrilov, V.; Lychkovskaya, N.; Popov, V.; Pozdnyakov, I.; Safronov, G.; Toms, M.; Zhokin, A.; Baskakov, A.; Belyaev, A.; Boos, E.; Dubinin, M.; Dudko, L.; Ershov, A.; Gribushin, A.; Kaminskiy, A.; Klyukhin, V.; Kodolova, O.; Lokhtin, I.; Miagkov, I.; Obraztsov, S.; Petrushanko, S.; Savrin, V.; Snigirev, A.; Andreev, V.; Azarkin, M.; Dremin, I.; Kirakosyan, M.; Leonidov, A.; Terkulov, A.; Bitioukov, S.; Elumakhov, D.; Kalinin, A.; Krychkine, V.; Mandrik, P.; Petrov, V.; Ryutin, R.; Sobol, A.; Troshin, S.; Volkov, A.; Sekmen, S.; Medvedeva, T.; Rumerio, P.; Adiguzel, A.; Bakirci, N.; Cerci, S.; Damarseckin, S.; Demiroglu, Z.S.; Dölek, F.; Dozen, C.; Dumanoglu, I.; Eskut, E.; Girgis, S.; Gokbulut, G.; Guler, Y.; Hos, I.; Kangal, E.E.; Kara, O.; Kayis Topaksu, A.; Işik, C.; Kiminsu, U.; Oglakci, M.; Onengut, G.; Ozdemir, K.; Ozturk, S.; Polatoz, A.; Sunar Cerci, D.; Tali, B.; Topakli, H.; Turkcapar, S.; Zorbakir, I.S.; Zorbilmez, C.; Bilin, B.; Isildak, B.; Karapinar, G.; Murat Guler, A.; Ocalan, K.; Yalvac, M.; Zeyrek, M.; Atakisi, I.O.; Gülmez, E.; Kaya, M.; Kaya, O.; Koseyan, O.K.; Ozcelik, O.; Ozkorucuklu, S.; Tekten, S.; Yetkin, E.A.; Yetkin, T.; Cankocak, K.; Sen, S.; Boyarintsev, A.; Grynyov, B.; Levchuk, L.; Popov, V.; Sorokin, P.; Flacher, H.; Borzou, A.; Call, K.; Dittmann, J.; Hatakeyama, K.; Liu, H.; Pastika, N.; Buccilli, A.; Cooper, S.I.; Henderson, C.; West, C.; Arcaro, D.; Gastler, D.; Hazen, E.; Rohlf, J.; Sulak, L.; Wu, S.; Zou, D.; Hakala, J.; Heintz, U.; Kwok, K.H.M.; Laird, E.; Landsberg, G.; Mao, Z.; Yu, D.R.; Gary, J.W.; Ghiasi Shirazi, S.M.; Lacroix, F.; Long, O.R.; Wei, H.; Bhandari, R.; Heller, R.; Stuart, D.; Yoo, J.H.; Chen, Y.; Duarte, J.; Lawhorn, J.M.; Nguyen, T.; Spiropulu, M.; Winn, D.; Abdullin, S.; Apresyan, A.; Apyan, A.; Banerjee, S.; Chlebana, F.; Freeman, J.; Green, D.; Hare, D.; Hirschauer, J.; Joshi, U.; Lincoln, D.; Los, S.; Pedro, K.; Spalding, W.J.; Strobbe, N.; Tkaczyk, S.; Whitbeck, A.; Linn, S.; Markowitz, P.; Martinez, G.; Bertoldi, M.; Hagopian, S.; Hagopian, V.; Kolberg, T.; Baarmand, M.M.; Noonan, D.; Roy, T.; Yumiceva, F.; Bilki, B.; Clarida, W.; Debbins, P.; Dilsiz, K.; Durgut, S.; Gandrajula, R.P.; Haytmyradov, M.; Khristenko, V.; Merlo, J.-P.; Mermerkaya, H.; Mestvirishvili, A.; Miller, M.; Moeller, A.; Nachtman, J.; Ogul, H.; Onel, Y.; Ozok, F.; Penzo, A.; Schmidt, I.; Snyder, C.; Southwick, D.; Tiras, E.; Yi, K.; Al-bataineh, A.; Bowen, J.; Castle, J.; McBrayer, W.; Murray, M.; Wang, Q.; Kaadze, K.; Maravin, Y.; Mohammadi, A.; Saini, L.K.; Baden, A.; Belloni, A.; Calderon, J.D.; Eno, S.C.; Feng, Y.B.; Ferraioli, C.; Grassi, T.; N.J.Hadley, G-Y Jeng; Kellogg, R.G.; Kunkle, J.; Mignerey, A.; Ricci-Tam, F.; Shin, Y.H.; Skuja, A.; Yang, Z.S.; Yao, Y.; Brandt, S.; D'Alfonso, M.; Hu, M.; Klute, M.; Niu, X.; Chatterjee, R.M.; Evans, A.; Frahm, E.; Kubota, Y.; Lesko, Z.; Mans, J.; Ruckstuhl, N.; Heering, A.; Karmgard, D.J.; Musienko, Y.; Ruchti, R.; Wayne, M.; Benaglia, A.D.; Mei, K.; Tully, C.; Bodek, A.; de Barbaro, P.; Galanti, M.; Garcia-Bellido, A.; Khukhunaishvili, A.; Lo, K.H.; Vishnevskiy, D.; Zielinski, M.; Agapitos, A.; Amouzegar, M.; Chou, J.P.; Hughes, E.; Saka, H.; Sheffield, D.; Akchurin, N.; Damgov, J.; De Guio, F.; Dudero, P.R.; Faulkner, J.; Gurpinar, E.; Kunori, S.; Lamichhane, K.; Lee, S.W.; Libeiro, T.; Mengke, T.; Muthumuni, S.; Undleeb, S.; Volobouev, I.; Wang, Z.; Goadhouse, S.; Hirosky, R.; Wang, Y.

    We study the light output, light collection efficiency and signal timing of a variety of organic scintillators that are being considered for the upgrade of the hadronic calorimeter of the CMS detector. The experimental data are collected at the H2 test-beam area at CERN, using a 150 GeV muon beam. In particular, we investigate the usage of over-doped and green-emitting plastic scintillator, two solutions that have not been extensively considered. We present a study of the energy distribution in plastic-scintillator tiles, the hit efficiency as a function of the hit position, and a study of the signal timing for blue and green scintillators.

  6. A new anti-neutrino detection technique based on positronium tagging with plastic scintillators

    CERN Document Server

    Consolati, G; Jollet, C; Meregaglia, A; Minotti, A; Perasso, S; Tonazzo, A

    2015-01-01

    The main signature for anti-neutrino detection in reactor and geo-neutrino experiments based on scintillators is provided by the space-time coincidence of positron and neutron produced in the Inverse Beta Decay reaction. Such a signature strongly suppresses backgrounds and allows for measurements performed underground with a relatively high signal-to-background ratio. In an aboveground environment, however, the twofold coincidence technique is not sufficient to efficiently reject the high background rate induced by cosmogenic events. Enhancing the positron-neutron twofold coincidence efficiency has the potential to pave the way future aboveground detectors for reactor monitoring. We propose a new detection scheme based on a threefold coincidence, between the positron ionization, the ortho-positronium (o-Ps) decay, and the neutron capture, in a sandwich detector with alternated layers of plastic scintillator and aerogel powder. We present the results of a set of dedicated measurements on the achievable light y...

  7. A GEANT4 study on the time resolution of a fast plastic scintillator read out by a G-APD

    Energy Technology Data Exchange (ETDEWEB)

    Sedlak, K., E-mail: kamil.sedlak@psi.ch [Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Stoykov, A.; Scheuermann, R. [Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland)

    2012-12-22

    The time resolution of a fast scintillation counter, consisting of a plastic scintillator read out by a Geiger-mode Avalanche Photodiode, is studied over a wide range of the number of detected photons (primary photoelectrons) using the GEANT4 simulation toolkit. Different timing definitions such as first photon detection, leading edge and constant fraction discrimination are considered. In the latter case the predictions are compared with the existing experimental data. We also show that due to the finite scintillation rise time, finite scintillator dimensions and also due to the finite single photon time resolution in G-APD cells, the time resolution for the first detected photon in real detectors substantially deviates from the {sigma}{approx}1/N{sub phe} dependence, theoretically predicted for a scintillator with zero rise time.

  8. A GEANT4 study on the time resolution of a fast plastic scintillator read out by a G-APD

    Science.gov (United States)

    Sedlak, K.; Stoykov, A.; Scheuermann, R.

    2012-12-01

    The time resolution of a fast scintillation counter, consisting of a plastic scintillator read out by a Geiger-mode Avalanche Photodiode, is studied over a wide range of the number of detected photons (primary photoelectrons) using the GEANT4 simulation toolkit. Different timing definitions such as first photon detection, leading edge and constant fraction discrimination are considered. In the latter case the predictions are compared with the existing experimental data. We also show that due to the finite scintillation rise time, finite scintillator dimensions and also due to the finite single photon time resolution in G-APD cells, the time resolution for the first detected photon in real detectors substantially deviates from the σ˜1/Nphe dependence, theoretically predicted for a scintillator with zero rise time.

  9. Optimization of the wavelength shifter ratio in a polystyrene based plastic scintillator through energy spectrum analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ye Won; Kim, Myung Soo; Yoo, Hyun Jun; Lee, Dae Hee; Cho, Gyu Seong [Dept. of Nuclear and Quantum Engineering, KAIST, Daejeon (Korea, Republic of); Moon, Myung Kook [Neutron Instrumentation Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2017-02-15

    The scintillation efficiency of the polystyrene based plastic scintillator depends on the ratio of the wavelength shifters, organic fluors (PPO and POPOP). Thus, 24 samples of the plastic scintillator were fabricated in order to find out the optimum ratio of the wavelength shifters in the plastic scintillator. The fabricated plastic scintillators were trimmed through a cutting and polishing process. They were used in gamma energy spectrum measurement with the {sup 137}Cs emitting monoenergy photon with 662 keV for the comparison of the scintillation efficiency. As a result, it was found out that the scintillator sample with 1.00 g of PPO (2,5-Diphenyloxazole) and 0.50 g of POPOP (1,4-Bis(5-phnyl-2oxidazolyl)benzene) dissolved in 100 g of styrene solution has the optimum ratio in terms of the light yield of the polystyrene based plastic scintillator.

  10. Plastic scintillators utilization in position sensitive detection systems; Uitilizacao de cintiladores plasticos em sistemas de deteccao sensiveis a posicao

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, Marcelo Bernardes; Soares, Adalberto Jose; Baptista Filho, Benedito Dias [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    2002-07-01

    This paper shows the viability of using a plastic scintillator detector to determine the one dimension position of a radioactive source. The experiments were performed using collimated {sup 99m} Tc sources of several activities supplied by the Centro de Radiofarmacia (from IPEN), and a 15 cm long plastic scintillator with diameter 5,08 cm, produced by the Centro de Tecnologia das Radiacoes (also from IPEN). The spectrum was obtained using the Genie 2000 software, and the results processed using a neural network specially developed for the proposed application. The final results demonstrate the viability of the proposed application. (author)

  11. Inorganic Scintillators for Detector Systems Physical Principles and Crystal Engineering

    CERN Document Server

    AUTHOR|(CDS)2068219; Gektin, Alexander; Korzhik, Mikhail; Pédrini, Christian

    2006-01-01

    The development of new scintillators as components of modern detector systems is increasingly defined by the end user's needs. This book provides an introduction to this emerging topic at the interface of physics and materials sciences, with emphasis on bulk inorganic scintillators. After surveying the end user's needs in a vast range of applications, ranging from astrophysics to industrial R & D, the authors move on to review scintillating mechanisms and the properties of the most important materials used. A chapter on crystal engineering and examples of recent developments in the field of high-energy physics and medical imaging introduce the reader to the practical aspects. This book will benefit researchers and scientists working in academic and industrial R & D related to the development of scintillators.

  12. Inorganic scintillators for detector systems physical principles and crystal engineering

    CERN Document Server

    Lecoq, Paul; Korzhik, Mikhail

    2017-01-01

    This second edition features new chapters highlighting advances in our understanding of the behavior and properties of scintillators, and the discovery of new families of materials with light yield and excellent energy resolution very close to the theoretical limit. The book focuses on the discovery of next-generation scintillation materials and on a deeper understanding of fundamental processes. Such novel materials with high light yield as well as significant advances in crystal engineering offer exciting new perspectives. Most promising is the application of scintillators for precise time tagging of events, at the level of 100 ps or higher, heralding a new era in medical applications and particle physics. Since the discovery of the Higgs Boson with a clear signature in the lead tungstate scintillating blocks of the CMS Electromagnetic Calorimeter detector, the current trend in particle physics is toward very high luminosity colliders, in which timing performance will ultimately be essential to mitigating...

  13. High-density scintillating glasses for a proton imaging detector

    Science.gov (United States)

    Tillman, I. J.; Dettmann, M. A.; Herrig, V.; Thune, Z. L.; Zieser, A. J.; Michalek, S. F.; Been, M. O.; Martinez-Szewczyk, M. M.; Koster, H. J.; Wilkinson, C. J.; Kielty, M. W.; Jacobsohn, L. G.; Akgun, U.

    2017-06-01

    High-density scintillating glasses are proposed for a novel proton-imaging device that can improve the accuracy of the hadron therapy. High-density scintillating glasses are needed to build a cost effective, compact calorimeter that can be attached to a gantry. This report summarizes the study on Europium, Terbium, and Cerium-doped scintillating glasses that were developed containing heavy elements such as Lanthanum, Gadolinium, and Tungsten. The density of the samples reach up to 5.9 g/cm3, and their 300-600 nm emission overlaps perfectly with the peak cathode sensitivity of the commercial photo detectors. The developed glasses do not require any special quenching and can be poured easily, which makes them a good candidate for production in various geometries. Here, the glass making conditions, preliminary tests on optical and physical properties of these scintillating, high-density, oxide glasses developed for a novel medical imaging application are reported.

  14. Development of a Scintillating Fibre Detector for HERA-B

    CERN Document Server

    Dreis, H B; Hildebrandt, M; Schmidt, B; Sponsel, A; Ziegler, M

    1998-01-01

    A fibre detector with multianode PM readout for high rate applications was developed for the HERA-B spectometer to cover the area near the beampipe. Such a detector has to operate at particle rates up to 2*10**4 mm**(-2) s**(-1) and has to tolerate a radiation dosis up to 1 Mrad/y. The light output of test detectors with different scintillating fibres was measured as well as the light transport through clear fibres to the PM as a function of radiation dosis and different conditions of irradiation. The geometry of the detector is described and results for a full size prototype are presented.

  15. Explore nuclearites in a large liquid scintillator neutrino detector

    CERN Document Server

    Guo, Wan-Lei; Lin, Tao; Wang, Zhi-Min

    2016-01-01

    We take the JUNO experiment as an example to explore nuclearites in the future large liquid scintillator detector. Comparing to the previous calculations, the visible energy of nuclearites across the liquid scintillator will be reestimated for the liquid scintillator based detector. Then the JUNO sensitivities to the nuclearite flux are presented. It is found that the JUNO projected sensitivities can be better than $7.7 \\times 10^{-17} {\\rm cm^{-2} s^{-1} sr^{-1}}$ for the nuclearite mass $10^{15} \\; {\\rm GeV} \\leq M \\leq 10^{24}$ GeV and initial velocity $10^{-4} \\leq \\beta_0 \\leq 10^{-1}$ with a 20 year running. Note that the JUNO will give the most stringent limits for downgoing nuclearites with $1.6 \\times 10^{13} \\; {\\rm GeV} \\leq M \\leq 4.0 \\times 10^{15}$ GeV and a typical galactic velocity $\\beta_0 = 10^{-3}$.

  16. Compensated bismuth-loaded plastic scintillators for neutron detection using low-energy pseudo-spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Dumazert, Jonathan, E-mail: jonathan.dumazert@cea.fr [CEA, LIST, Laboratoire Capteurs Architectures Electroniques, 91191 Gif-sur-Yvette (France); Coulon, Romain; Bertrand, Guillaume H.V.; Normand, Stéphane [CEA, LIST, Laboratoire Capteurs Architectures Electroniques, 91191 Gif-sur-Yvette (France); Méchin, Laurence [CNRS, UCBN, Groupe de Recherche en Informatique, Image, Automatique et Instrumentation de Caen, 14050 Caen (France); Hamel, Matthieu [CEA, LIST, Laboratoire Capteurs Architectures Electroniques, 91191 Gif-sur-Yvette (France)

    2016-05-21

    Gadolinium-covered modified plastic scintillators show a high potential for the deployment of cost-effective neutron detectors. Taking advantage of the low-energy photon and electron signature of thermal neutron captures in gadolinium-155 and gadolinium-157 however requires a background correction. In order to display a trustable rate, dual compensation schemes appear as an alternative to Pulse Shape Discrimination. This paper presents the application of such a compensation scheme to a two-bismuth loaded plastic scintillator system. A detection scintillator interacts with incident photon and fast neutron radiations and is covered with a gadolinium converter to become thermal neutron-sensitive as well. In the meantime, an identical compensation scintillator, covered with terbium, solely interacts with the photon and fast neutron part of incident radiations. After the acquisition and the treatment of the counting signals from both sensors, a hypothesis test determines whether the resulting count rate after subtraction falls into statistical fluctuations or provides a robust image of neutron activity. A laboratory prototype is tested under both photon and neutron radiations, allowing us to investigate the performance of the overall compensation system. The study reveals satisfactory results in terms of robustness to a cesium-137 background and in terms of sensitivity in presence of a californium-252 source.

  17. Compensated bismuth-loaded plastic scintillators for neutron detection using low-energy pseudo-spectroscopy

    Science.gov (United States)

    Dumazert, Jonathan; Coulon, Romain; Bertrand, Guillaume H. V.; Normand, Stéphane; Méchin, Laurence; Hamel, Matthieu

    2016-05-01

    Gadolinium-covered modified plastic scintillators show a high potential for the deployment of cost-effective neutron detectors. Taking advantage of the low-energy photon and electron signature of thermal neutron captures in gadolinium-155 and gadolinium-157 however requires a background correction. In order to display a trustable rate, dual compensation schemes appear as an alternative to Pulse Shape Discrimination. This paper presents the application of such a compensation scheme to a two-bismuth loaded plastic scintillator system. A detection scintillator interacts with incident photon and fast neutron radiations and is covered with a gadolinium converter to become thermal neutron-sensitive as well. In the meantime, an identical compensation scintillator, covered with terbium, solely interacts with the photon and fast neutron part of incident radiations. After the acquisition and the treatment of the counting signals from both sensors, a hypothesis test determines whether the resulting count rate after subtraction falls into statistical fluctuations or provides a robust image of neutron activity. A laboratory prototype is tested under both photon and neutron radiations, allowing us to investigate the performance of the overall compensation system. The study reveals satisfactory results in terms of robustness to a cesium-137 background and in terms of sensitivity in presence of a californium-252 source.

  18. Experimental verification of gamma-efficiency calculations for scintillation detectors in ANGLE 4 software

    National Research Council Canada - National Science Library

    Thabet Abouzeid A; Dlabac Aleksandar D; Jovanovic Slobodan I; Badawi Mohamed S; Mihaljevic Nikola N; El-Khatib Ahmed M; Gouda Mona M; Abbas Mahmoud I

    2015-01-01

    ANGLE software for semiconductor detector efficiency calculations - long existing and widely accepted tool in quantitative gamma spectrometry - has been recently extended to scintillation NaI detectors...

  19. Fast scintillation detectors for high-energy X-ray region

    Science.gov (United States)

    Kishimoto, Shunji; Nishikido, Fumihiko; Haruki, Rie; Shibuya, Kengo; Koshimizu, Masanori

    2012-03-01

    We have developed fast scintillation detectors for nuclear resonant scattering experiments using synchrotron radiation and a nuclear excited level existing in >30 keV. A fast x-ray detector using an organic-inorganic perovskite scintillator of phenethylamine lead bromide (PhE-PbBr4) had a dominant light emission with a fast decay time of 9.9 ns. An x-ray detector equipped with a 0.9-mm-thick PhE-PbBr4 crystal (size: ˜8 × 7 mm2) was used to detect nuclear resonant scattering in 61Ni (the first excited level: 67.41 keV; half-life: 5.3 ns). We could successfully record the decaying gamma rays emitted from 61Ni with a relatively high detection efficiency of 24%. A lead-doped plastic scintillator (NE142, Pb ˜5 wt% doped) had been known to have a faster decay time of 1.7 ns. Following a test of a single NE142 detector, a four-channel NE142 detector was fabricated and successfully applied to the synchrotron-radiation based Mössbauer spectroscopy experiment on 61Ni.

  20. Proton beam dosimetry: a comparison between a plastic scintillator, ionization chamber and Faraday cup.

    Science.gov (United States)

    Ghergherehchi, Mitra; Afarideh, Hossein; Ghannadi, Mohammad; Mohammadzadeh, Ahmad; Aslani, Golam Reza; Boghrati, Behzad

    2010-01-01

    In this study, a comparison was made between a plastic scintillator (BC400), a Faraday Cup (FC) and an ionization chamber (IC) used for routine proton dosimetry. Thin scintillators can be applied to proton dosimetry and consequently to proton therapy as relative dosimeters because of their water-equivalent nature, high energy-light conversion efficiency, low dimensions and good proportionality to the absorbed dose at low stopping powers. To employ such scintillators as relative dosimeters in proton therapy, the corrective factors must be applied to correct the quenching luminescence at the Bragg peak. A fine linear proportionality between the luminescence light yield Y and the proton flux in a thin (0.5 mm) scintillator for the 20 and 30 MeV proton beams were observed. The experimental peak/plateau ratios of Bragg Curve for 2, 1 and 0.5 mm scintillators with an accuracy of 0.5% were obtained to be 1.87, 1.91 and 2.30, respectively. With combination of the Markus chamber and the CR-39 detector, the peak/plateau ratio was improved to 3.26. The obtained data of the luminescence yield as a function of the specific energy loss is in agreement with the Craun-Birk's theory. Results show that the FC and Markus ionization chamber are in agreement within 4%, while the FC gives a lower dose evaluation. For a defined beam, the data for the fluence measurements are reproducible within a good accuracy.

  1. A capture-gated neutron calorimeter using plastic scintillators and 3He drift tubes

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zhehui [Los Alamos National Laboratory; Morris, Christopher L [Los Alamos National Laboratory; Spaulding, Randy J [Los Alamos National Laboratory; Bacon, Jeffrey D [Los Alamos National Laboratory; Borozdin, Konstantin N [Los Alamos National Laboratory; Chung, Kiwhan [Los Alamos National Laboratory; Clark, Deborah J [Los Alamos National Laboratory; Green, Jesse A [Los Alamos National Laboratory; Greene, Steven J [Los Alamos National Laboratory; Hogan, Gary E [Los Alamos National Laboratory; Jason, Andrew [Los Alamos National Laboratory; Lisowski, Paul W [Los Alamos National Laboratory; Makela, Mark F [Los Alamos National Laboratory; Mariam, Fessaha G [Los Alamos National Laboratory; Miyadera, Haruo [Los Alamos National Laboratory; Murray, Matthew M [Los Alamos National Laboratory; Saunders, Alexander [Los Alamos National Laboratory; Wysocki, Frederick J [Los Alamos National Laboratory; Gray, Frederick E [REGIS UNIV.

    2010-01-01

    A segmented neutron calorimeter using nine 4-inch x 4-inch x 48-inch plastic scintillators and sixteen 2-inch-diameter 48-inch-long 200-mbar-{sup 3}He drift tubes is described. The correlated scintillator and neutron-capture events provide a means for n/{gamma} discrimination, critical to the neutron calorimetry when the {gamma} background is substantial and the {gamma} signals are comparable in amplitude to the neutron signals. A single-cell prototype was constructed and tested. It can distinguish between a {sup 17}N source and a {sup 252}Cf source when the {gamma} and the thermal neutron background are sufficiently small. The design and construction of the nine-cell segmented detector assembly follow the same principle. By recording the signals from individual scintillators, additional {gamma}-subtraction schemes, such as through the time-of-flight between two scintillators, may also be used. The variations of the light outputs from different parts of a scintillator bar are less than 10%.

  2. A scintillator purification system for the Borexino solar neutrino detector

    Science.gov (United States)

    Benziger, J.; Cadonati, L.; Calaprice, F.; Chen, M.; Corsi, A.; Dalnoki-Veress, F.; Fernholz, R.; Ford, R.; Galbiati, C.; Goretti, A.; Harding, E.; Ianni, Aldo; Ianni, Andrea; Kidner, S.; Leung, M.; Loeser, F.; McCarty, K.; McKinsey, D.; Nelson, A.; Pocar, A.; Salvo, C.; Schimizzi, D.; Shutt, T.; Sonnenschein, A.

    2008-03-01

    Purification of the 278 tons of liquid scintillator and 889 tons of buffer shielding for the Borexino solar neutrino detector is performed with a system that combines distillation, water extraction, gas stripping, and filtration. This paper describes the principles of operation, design, and construction of that purification system, and reviews the requirements and methods to achieve system cleanliness and leak-tightness.

  3. Position Reconstruction in a Dual Phase Xenon Scintillation Detector

    CERN Document Server

    Solovov, V N; Akimov, D Yu; Araújo, H M; Barnes, E J; Burenkov, A A; Chepel, V; Currie, A; DeViveiros, L; Edwards, B; Ghag, C; Hollingsworth, A; Horn, M; Kalmus, G E; Kobyakin, A S; Kovalenko, A G; Lebedenko, V N; Lindote, A; Lopes, M I; Lüscher, R; Majewski, P; Murphy, A St J; Neves, F; Paling, S M; da Cunha, J Pinto; Preece, R; Quenby, J J; Reichhart, L; Scovell, P R; Silva, C; Smith, N J T; Smith, P F; Stekhanov, V N; Sumner, T J; Thorne, C; Walker, R J

    2011-01-01

    We studied the application of statistical reconstruction algorithms, namely maximum likelihood and least squares methods, to the problem of event reconstruction in a dual phase liquid xenon detector. An iterative method was developed for in-situ reconstruction of the PMT light response functions from calibration data taken with an uncollimated gamma-ray source. Using the techniques described, the performance of the ZEPLIN-III dark matter detector was studied for 122 keV gamma-rays. For the inner part of the detector (R<100 mm), spatial resolutions of 13 mm and 1.6 mm FWHM were measured in the horizontal plane for primary and secondary scintillation, respectively. An energy resolution of 8.1% FWHM was achieved at that energy. The possibility of using this technique for improving performance and reducing cost of scintillation cameras for medical applications is currently under study.

  4. Organic Scintillator Detector Response Simulations with DRiFT

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, Madison Theresa [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Bates, Cameron Russell [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mckigney, Edward Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rising, Michael Evan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pinilla, Maria Isabel [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Solomon, Jr., Clell Jeffrey [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Sood, Avneet [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-12-19

    Accurate detector modeling is a requirement to design systems in many non-proliferation scenarios; by determining a Detector’s Response Function (DRF) to incident radiation, it is possible characterize measurements of unknown sources. DRiFT is intended to post-process MCNP® output and create realistic detector spectra. Capabilities currently under development include the simulation of semiconductor, gas, and (as is discussed in this work) scintillator detector physics. Energy spectra and pulse shape discrimination (PSD) trends for incident photon and neutron radiation have been reproduced by DRiFT.

  5. Memory effect, resolution, and efficiency measurements of an Al2O3 coated plastic scintillator used for radioxenon detection

    Science.gov (United States)

    Bläckberg, L.; Fritioff, T.; Mårtensson, L.; Nielsen, F.; Ringbom, A.; Sjöstrand, H.; Klintenberg, M.

    2013-06-01

    A cylindrical plastic scintillator cell, used for radioxenon monitoring within the verification regime of the Comprehensive Nuclear-Test-Ban Treaty, has been coated with 425 nm Al2O3 using low temperature Atomic Layer Deposition, and its performance has been evaluated. The motivation is to reduce the memory effect caused by radioxenon diffusing into the plastic scintillator material during measurements, resulting in an elevated detection limit. Measurements with the coated detector show both energy resolution and efficiency comparable to uncoated detectors, and a memory effect reduction of a factor of 1000. Provided that the quality of the detector is maintained for a longer period of time, Al2O3 coatings are believed to be a viable solution to the memory effect problem in question.

  6. Plutonium metal vs. oxide determination with the pulse-shape-discrimination-capable plastic scintillator EJ-299-33

    Energy Technology Data Exchange (ETDEWEB)

    Pozzi, S.A., E-mail: pozzisa@umich.edu [Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109 (United States); Bourne, M.M.; Dolan, J.L.; Polack, K.; Lawrence, C.; Flaska, M.; Clarke, S.D. [Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109 (United States); Tomanin, A.; Peerani, P. [European Commission Joint Research Centre, Institute for the Protection and Security of the Citizen Via Enrico Fermi, 2749 21027 Ispra VA (Italy)

    2014-12-11

    Neutron measurements can be used to distinguish plutonium in metal or oxide form, a capability that is of great interest in nuclear nonproliferation, treaty verification, and other applications. This paper describes measurements performed on well-characterized samples of plutonium oxide and plutonium metal using the pulse-shape-discrimination-capable plastic scintillator EJ-299-33. Results are compared to those obtained with a same-sized detector cell using the liquid scintillator EJ-309. The same optimized, digital pulse shape discrimination technique is applied to both detectors and the neutron pulse height distributions are compared. Results show that the EJ-299-33 plastics can be successfully used for plutonium measurements, where the gamma ray to neutron detection ratio is much higher than for typical radioactive sources. Results also show that EJ-299-33 detectors can be used to characterize plutonium samples, specifically to discriminate between plutonium metal and oxide.

  7. High-Z Nanoparticle/Polymer Nanocomposites for Gamma-Ray Scintillation Detectors

    Science.gov (United States)

    Liu, Chao

    An affordable and reliable solution for spectroscopic gamma-ray detection has long been sought after due to the needs from research, defense, and medical applications. Scintillators resolve gamma energy by proportionally converting a single high-energy photon into a number of photomultiplier-tube-detectable low-energy photons, which is considered a more affordable solution for general purposes compared to the delicate semiconductor detectors. An ideal scintillator should simultaneously exhibit the following characteristics: 1) high atomic number (Z) for high gamma stopping power and photoelectron production; 2) high light yield since the energy resolution is inversely proportional to the square root of light yield; 3) short emission decay lifetime; and 4) low cost and scalable production. However, commercial scintillators made from either inorganic single crystals or plastics fail to satisfy all requirements due to their intrinsic material properties and fabrication limitations. The concept of adding high-Z constituents into plastic scintillators to harness high Z, low cost, and fast emission in the resulting nanocomposite scintillators is not new in and of itself. Attempts have been made by adding organometallics, quantum dots, and scintillation nanocrystals into the plastic matrix. High-Z organometallics have long been used to improve the Z of plastic scintillators; however, their strong spin-orbit coupling effect entails careful triplet energy matching using expensive triplet emitters to avoid severe quenching of the light yield. On the other hand, reported quantum dot- and nanocrystal-polymer nanocomposites suffer from moderate Z and high optical loss due to aggregation and self-absorption at loadings higher than 10 wt%, limiting their potential for practical application. This dissertation strives to improve the performance of nanoparticle-based nanocomposite scintillators. One focus is to synthesize transparent nanocomposites with higher loadings of high

  8. Two-dimensional X-ray imaging using plastic scintillating fiber array

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Due to its low cost,flexibility and convenience for long distance dala transfer,plastic scintillation fiber (PSF)have been increasingly used in building detectors or sensors for detecting various radiations and imaging.In this work,the performance of using PSF coupled with charge-coupled devices(CCD)to build are adetectors for 2D X-ray imaging is studied.We describe the experimental setup and show the obtained images from CCD.Modulation Transfer Function(MTF)of the PSF array is also presented and compared to earlier reports.

  9. Dose verification of radiotherapy for lung cancer by using plastic scintillator dosimetry and a heterogeneous phantom

    DEFF Research Database (Denmark)

    Ottosson, Wiviann; Behrens, C. F.; Andersen, Claus E.

    2015-01-01

    Bone, air passages, cavities, and lung are elements present in patients, but challenging to properly correct for in treatment planning dose calculations. Plastic scintillator detectors (PSDs) have proven to be well suited for dosimetry in non-reference conditions such as small fields. The objective...... of this study was to investigate the performance of a commercial treatment planning system (TPS) using a PSD and a specially designed thorax phantom with lung tumor inserts. 10 treatment plans of different complexity and phantom configurations were evaluated. Although the TPS agreed well with the measurements...

  10. Time correlated measurements using plastic scintillators with neutron-photon pulse shape discrimination

    Science.gov (United States)

    Richardson, Norman E., IV

    nuclear and radiological material. Moreover, the production of 3He isotope as a byproduct of security programs was drastically decreased. This isotope shortage coupled with the disadvantages of relying on a detector that requires neutron moderation before the detection of fission neutrons, poses a significant challenge in supporting the existing detection systems and the development of future technologies. To address this problem, a reliable and accurate alternative technology to detect neutrons emitted in fissions must be developed. One such alternative technology that shows promise in this application is the use of scintillators based on solid state materials (plastics) which are sensitive to fast neutrons. However, plastic scintillators are also sensitive to photons. Hence, it is necessary to separate the neutron signals from the photon signals, using the pulse shape discrimination (PSD) analysis. The PSD is based on the comparison of the pulse shapes of digitized signal waveforms. This approach allows for the measurement of fast neutrons without the necessity of their moderation. Because the fission spectrum neutrons are mainly fast, methods employing fast neutron detection are applicable for the assay of fissile materials. In addition, the average time of scintillation of the plastic medium is much shorter than those of the gaseous counters, thus allowing scintillation detectors to be used in high count rate environments. Furthermore, the temporal information of the fast neutron detection using multiple sensors enables the time correlation analysis of the fission neutron multiplicity. The study of time correlation measurements of fast neutrons using the array of plastic scintillators is the basis of this work. The array of four plastic scintillator detectors equipped with the digital data acquisition and analysis system was developed. The digital PSD analysis of detector signals "on-the-fly" was implemented for the array. The time coincidence measurement technique

  11. Application of a free parameter model to plastic scintillation samples

    Energy Technology Data Exchange (ETDEWEB)

    Tarancon Sanz, Alex, E-mail: alex.tarancon@ub.edu [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 647, E-08028 Barcelona (Spain); Kossert, Karsten, E-mail: Karsten.Kossert@ptb.de [Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig (Germany)

    2011-08-21

    In liquid scintillation (LS) counting, the CIEMAT/NIST efficiency tracing method and the triple-to-double coincidence ratio (TDCR) method have proved their worth for reliable activity measurements of a number of radionuclides. In this paper, an extended approach to apply a free-parameter model to samples containing a mixture of solid plastic scintillation microspheres and radioactive aqueous solutions is presented. Several beta-emitting radionuclides were measured in a TDCR system at PTB. For the application of the free parameter model, the energy loss in the aqueous phase must be taken into account, since this portion of the particle energy does not contribute to the creation of scintillation light. The energy deposit in the aqueous phase is determined by means of Monte Carlo calculations applying the PENELOPE software package. To this end, great efforts were made to model the geometry of the samples. Finally, a new geometry parameter was defined, which was determined by means of a tracer radionuclide with known activity. This makes the analysis of experimental TDCR data of other radionuclides possible. The deviations between the determined activity concentrations and reference values were found to be lower than 3%. The outcome of this research work is also important for a better understanding of liquid scintillation counting. In particular the influence of (inverse) micelles, i.e. the aqueous spaces embedded in the organic scintillation cocktail, can be investigated. The new approach makes clear that it is important to take the energy loss in the aqueous phase into account. In particular for radionuclides emitting low-energy electrons (e.g. M-Auger electrons from {sup 125}I), this effect can be very important.

  12. New scintillating media based on liquid crystals for particle detectors

    CERN Document Server

    Barnik, M I; Vasilchenko, V G; Golovkin, S V; Medvedkov, A M; Soloviev, A S

    2000-01-01

    The study results of optical, photoluminiscent and scintillation properties of a liquid crystal 4-pentyl-4'-cyanobiphenyl are presented. The scintillation light output of this liquid crystal is about 35% of crystal anthracene, its main decay time constants are 4 and 14 ns, and the maximum of light emission spectrum is about 400 nm. The light output of a dissolution of green emitting light scintillation dopant R6 in the liquid crystal is about 120% of crystal anthracene. The light output of the frozen dissolution measured at -112 deg. C is about 2.5 times higher as observed at +20 deg. C. In the uniaxially oriented liquid crystal, the predominant intensity direction of emitted light is pointed perpendicular to the liquid crystal director and an appreciable part of the emitted light is elliptically polarized. The possibility to use scintillation properties of liquid crystals is considered both for the improvement of existing particle detector characteristics and for the creation of new gated particle detectors.

  13. Sensitive and transportable gadolinium-core plastic scintillator sphere for neutron detection and counting

    Energy Technology Data Exchange (ETDEWEB)

    Dumazert, Jonathan; Coulon, Romain; Carrel, Frédérick; Corre, Gwenolé; Normand, Stéphane [CEA, LIST, Laboratoire Capteurs Architectures Electroniques, 91191 Gif-sur-Yvette (France); Méchin, Laurence [CNRS, UCBN, Groupe de Recherche en Informatique, Image, Automatique et Instrumentation de Caen, 14050 Caen (France); Hamel, Matthieu [CEA, LIST, Laboratoire Capteurs Architectures Electroniques, 91191 Gif-sur-Yvette (France)

    2016-08-21

    Neutron detection forms a critical branch of nuclear-related issues, currently driven by the search for competitive alternative technologies to neutron counters based on the helium-3 isotope. The deployment of plastic scintillators shows a high potential for efficient detectors, safer and more reliable than liquids, more easily scalable and cost-effective than inorganic. In the meantime, natural gadolinium, through its 155 and mostly 157 isotopes, presents an exceptionally high interaction probability with thermal neutrons. This paper introduces a dual system including a metal gadolinium core inserted at the center of a high-scale plastic scintillator sphere. Incident fast neutrons are thermalized by the scintillator shell and then may be captured with a significant probability by gadolinium 155 and 157 nuclei in the core. The deposition of a sufficient fraction of the capture high-energy prompt gamma signature inside the scintillator shell will then allow discrimination from background radiations by energy threshold, and therefore neutron detection. The scaling of the system with the Monte Carlo MCNPX2.7 code was carried out according to a tradeoff between the moderation of incident fast neutrons and the probability of slow neutron capture by a moderate-cost metal gadolinium core. Based on the parameters extracted from simulation, a first laboratory prototype for the assessment of the detection method principle has been synthetized. The robustness and sensitivity of the neutron detection principle are then assessed by counting measurement experiments. Experimental results confirm the potential for a stable, highly sensitive, transportable and cost-efficient neutron detector and orientate future investigation toward promising axes.

  14. Sensitive and transportable gadolinium-core plastic scintillator sphere for neutron detection and counting

    Science.gov (United States)

    Dumazert, Jonathan; Coulon, Romain; Carrel, Frédérick; Corre, Gwenolé; Normand, Stéphane; Méchin, Laurence; Hamel, Matthieu

    2016-08-01

    Neutron detection forms a critical branch of nuclear-related issues, currently driven by the search for competitive alternative technologies to neutron counters based on the helium-3 isotope. The deployment of plastic scintillators shows a high potential for efficient detectors, safer and more reliable than liquids, more easily scalable and cost-effective than inorganic. In the meantime, natural gadolinium, through its 155 and mostly 157 isotopes, presents an exceptionally high interaction probability with thermal neutrons. This paper introduces a dual system including a metal gadolinium core inserted at the center of a high-scale plastic scintillator sphere. Incident fast neutrons are thermalized by the scintillator shell and then may be captured with a significant probability by gadolinium 155 and 157 nuclei in the core. The deposition of a sufficient fraction of the capture high-energy prompt gamma signature inside the scintillator shell will then allow discrimination from background radiations by energy threshold, and therefore neutron detection. The scaling of the system with the Monte Carlo MCNPX2.7 code was carried out according to a tradeoff between the moderation of incident fast neutrons and the probability of slow neutron capture by a moderate-cost metal gadolinium core. Based on the parameters extracted from simulation, a first laboratory prototype for the assessment of the detection method principle has been synthetized. The robustness and sensitivity of the neutron detection principle are then assessed by counting measurement experiments. Experimental results confirm the potential for a stable, highly sensitive, transportable and cost-efficient neutron detector and orientate future investigation toward promising axes.

  15. Development of TOF-PET using Compton scattering by plastic scintillators

    Science.gov (United States)

    Kuramoto, M.; Nakamori, T.; Kimura, S.; Gunji, S.; Takakura, M.; Kataoka, J.

    2017-02-01

    We propose a time-of-flight (TOF) technique using plastic scintillators which have fast decay time of a few ns for positron emission tomography (PET). While the photoelectric absorption probability of the plastic for 511 keV gamma rays are extremely low due to its small density and effective atomic number, the cross section of Compton scattering is comparable to that of absorption by conventional inorganic scintillators. We thus propose TOF-PET using Compton scattering with plastic scintillators (Compton-PET), and performed fundamental experiments towards exploration of the Compton-PET capability. We demonstrated that the plastic scintillators achieved the better time resolution in comparison to LYSO(Ce) and GAGG(Ce) scintillators. In addition we evaluated the depth-of-interaction resolving capability with the plastic scintillators.

  16. Compensated gadolinium-loaded plastic scintillators for thermal neutron detection (and counting)

    Energy Technology Data Exchange (ETDEWEB)

    Dumazert, Jonathan; Coulon, Romain; Bertrand, Guillaume H. V.; Hamel, Matthieu; Sguerra, Fabien; Dehe-Pittance, Chrystele; Normand, Stephane [CEA, LIST, Laboratoire Capteurs Architectures Electroniques, 99 Gif-sur-Yvette, (France); Mechin, Laurence [CNRS, UCBN, Groupe de Recherche en Informatique, Image, Automatique et Instrumentation de Caen, 4050 Caen, (France)

    2015-07-01

    Plastic scintillator loading with gadolinium-rich organometallic complexes shows a high potential for the deployment of efficient and cost-effective neutron detectors. Due to the low-energy photon and electron signature of thermal neutron capture by gadolinium-155 and gadolinium-157, alternative treatment to Pulse Shape Discrimination has to be proposed in order to display a trustable count rate. This paper discloses the principle of a compensation method applied to a two-scintillator system: a detection scintillator interacts with photon radiation and is loaded with gadolinium organometallic compound to become a thermal neutron absorber, while a non-gadolinium loaded compensation scintillator solely interacts with the photon part of the incident radiation. Posterior to the nonlinear smoothing of the counting signals, a hypothesis test determines whether the resulting count rate after photon response compensation falls into statistical fluctuations or provides a robust image of a neutron activity. A laboratory prototype is tested under both photon and neutron irradiations, allowing us to investigate the performance of the overall compensation system in terms of neutron detection, especially with regards to a commercial helium-3 counter. The study reveals satisfactory results in terms of sensitivity and orientates future investigation toward promising axes. (authors)

  17. A large acceptance scintillator detector with wavelength shifting fibre readout for search of η-nucleus bound states

    Science.gov (United States)

    Betigeri, M. G.; Biswas, P. K.; Budzanowski, A.; Chatterjee, A.; Jahn, R.; Guha, S.; Hawranek, P.; Jain, B. K.; Jawale, S. B.; Jha, V.; Kilian, K.; Kliczewski, S.; Kirillov, Da.; Kirillov, Di.; Kolev, D.; Kravcikova, M.; Kutsarova, T.; Lesiak, M.; Lieb, J.; Machner, H.; Magiera, A.; Maier, R.; Martinska, G.; Nedev, S.; Piskunov, N.; Prasuhn, D.; Protić, D.; Ritman, J.; von Rossen, P.; Roy, B. J.; Shukla, P.; Sitnik, I.; Siudak, R.; Tsenov, R.; Ulicny, M.; Urban, J.; Vankova, G.; GEM Collaboration

    2007-07-01

    A large acceptance scintillator detector with wavelength shifting optical fibre readout has been designed and built to detect the decay particles of η-nucleus bound system (the so-called η-mesic nuclei), namely, protons and pions. The detector, named as ENSTAR detector, consists of 122 pieces of plastic scintillator of various shapes and sizes, which are arranged in a cylindrical geometry to provide particle identification, energy loss and coarse position information for these particles. A solid angle coverage of ˜95% of total 4 π is obtained in the present design of the detector. Monte Carlo phase space calculations performed to simulate the formation and decay of η-mesic nuclei suggest that its decay particles, the protons and pions are emitted with an opening angle of 150±20∘, and with energies in the range of 25-300 and 225-450 MeV, respectively. The detailed GEANT simulations show that ˜80 % of the decay particles (protons and pions) can be detected within ENSTAR. Several test measurements using alpha source, cosmic-ray muons, etc. have been carried out to study the response of ENSTAR scintillator pieces. The in-beam tests of fully assembled detector with proton beam of momentum 870 MeV/c from the Cooler synchrotron COSY have been performed. The test results show that the scintillator fibre design chosen for the detector has performed satisfactorily well. The present article describes the detector design, simulation studies, construction details and test results.

  18. A large acceptance scintillator detector with wavelength shifting fibre readout for search of {eta}-nucleus bound states

    Energy Technology Data Exchange (ETDEWEB)

    Betigeri, M.G.; Chatterjee, A.; Roy, B.J.; Shukla, P. [Nuclear Physics Div., BARC, Mumbai 400 085 (India); Biswas, P.K.; Guha, S.; Jawale, S.B. [Centre for Design and Manufacture, BARC, Mumbai 400 085 (India); Budzanowski, A. [Inst. of Nuclear Physics, Polish Academy of Sciences, Krakow (Poland); Jahn, R. [Helmholtz-Inst. fuer Strahlen- und Kernphysik der Univ. Bonn, Bonn (Germany); Hawranek, P. [Inst. of Physics, Jagellonian Univ., Krakow (Poland); Jain, B.K. [Physics Dept., Mumbai Univ., Vidyanagari, Mumbai (India); Jha, V. [Nuclear Physics Div., BARC, Mumbai 400 085 (India)]. E-mail: vjha@barc.gov.in; Kilian, K.; Kirillov, Da.; Lesiak, M.; Maier, R.; Prasuhn, D.; Protic, D.; Ritman, J.; von Rossen, P. [Inst. fuer Kernphysik, Forschungszentrum Juelich, Juelich (Germany); Kliczewski, S. [Inst. of Nuclear Physics, Polish Academy of Sciences, Krakow (Poland); Kirillov, Di.; Piskunov, N.; Sitnik, I. [Lab. for High Energies, JINR Dubna (Russian Federation); Kolev, D. [Physics Faculty, Univ. of Sofia, Sofia (Bulgaria); Kravcikova, M. [Technical Univ. Kosice, Kosice (Slovakia); Kutsarova, T. [Inst. of Nuclear Physics and Nuclear Energy, Sofia (Bulgaria); Lieb, J. [Physics Dept., George Mason Univ., Fairfax, VA (United States); Machner, H. [Inst. fuer Kernphysik, Forschungszentrum Juelich, Juelich (Germany)]|[Fachbereich Physik, Univ. Duisburg-Essen, Duisburg (Germany); Magiera, A. [Inst. of Physics, Jagellonian Univ., Krakow (Poland); Martinska, G.; Ulicny, M.; Urban, J. [P. J. Safarik Univ., Kosice, (Slovakia); Nedev, S. [Univ. of Chemical Technology and Metallurgy, Sofia (Bulgaria); Siudak, R. [Inst. of Nuclear Physics, Polish Academy of Sciences, Krakow (Poland)]|[Inst. fuer Kernphysik, Forschungszentrum Juelich, Juelich (Germany); Tsenov, R. [Physics Faculty, Univ. of Sofia, Sofia (Bulgaria); Vankova, G. [Inst. fuer Kernphysik, Forschungszentrum Juelich, Juelich (Germany)]|[Physics Faculty, Univ. of Sofia, Sofia (Bulgaria)

    2007-07-21

    A large acceptance scintillator detector with wavelength shifting optical fibre readout has been designed and built to detect the decay particles of {eta}-nucleus bound system (the so-called {eta}-mesic nuclei), namely, protons and pions. The detector, named as ENSTAR detector, consists of 122 pieces of plastic scintillator of various shapes and sizes, which are arranged in a cylindrical geometry to provide particle identification, energy loss and coarse position information for these particles. A solid angle coverage of {approx}95% of total 4{pi} is obtained in the present design of the detector. Monte Carlo phase space calculations performed to simulate the formation and decay of {eta}-mesic nuclei suggest that its decay particles, the protons and pions are emitted with an opening angle of 150+/-20{sup a}t, and with energies in the range of 25-300 and 225-450MeV, respectively. The detailed GEANT simulations show that {approx}80 % of the decay particles (protons and pions) can be detected within ENSTAR. Several test measurements using alpha source, cosmic-ray muons, etc. have been carried out to study the response of ENSTAR scintillator pieces. The in-beam tests of fully assembled detector with proton beam of momentum 870MeV/c from the Cooler synchrotron COSY have been performed. The test results show that the scintillator fibre design chosen for the detector has performed satisfactorily well. The present article describes the detector design, simulation studies, construction details and test results.

  19. Multilayer Scintillation Detector for Nuclear Physics Monitoring of Space Weather

    Science.gov (United States)

    Aleksandrin, Sergey; Mayorov, Andrey; Koldashov, Sergey; Batischev, Alexey; Lapushkin, Sergey; Gurov, Yury

    The physical characteristics of the multilayer scintillation spectrometer for identification and energy measurement of cosmic electrons, positrons and nuclei are considered in this presentation. The nuclei energy measurement range is 3-100 MeV/nucleon. This spectrometer is planning for space weather monitoring and investigation of solar-magnetospheric and geophysics effects on satellite. These characteristics were estimated by means of computer simulation. The ionization loss fluctuations, ion charge exchange during pass through detector and, especially, scintillation quenching effect (Bircs effect) were taken into account in calculations. The main results are: 1.) Ions mass identification is possible for hydrogen and helium isotopes 2.) Ions charge identification without mass identification is possible for nuclei from lithium to oxygen The preliminary estimation indicate, that including to spectrometer of thin semiconductor detector (SCD) as first layer makes possible charge identification for Z>8. This may be done by means of comparison of ion range in spectrometer with its energy loss in SCD.

  20. Investigation of scintillation detectors for relativistic heavy ion calorimetry

    CERN Document Server

    Lozeva, R; Balabanski, D L; Gerl, J; Górska, M; Kojouharov, I; Kopatch, Y; Mandal, S; Schaffner, H; Wollersheim, H J

    2003-01-01

    The new DELTA E/E detection system, calorimeter telescope (CATE), for charge and mass determination of heavy ions at high energies (>=100 MeV/n) has been designed. CATE, a calorimeter telescope will consist of position sensitive Si detectors for DELTA E determination and scintillators, readout by either PIN diode or PMT, for total-E determination. Different scintillation detectors were tested with sup 1 sup 3 sup 0 Sn, sup 1 sup 8 sup 6 Pb, sup 1 sup 9 sup 7 Au and sup 2 sup 3 sup 8 U beams of (100-300) MeV/n ion energy. By properly selecting the beam species from the FRS and applying position corrections, an energy resolution of approx =0.5% FWHM was observed. The corresponding mass resolution of 1/200 is adequate for employment of CATE in the Fast Beam RISING campaign at GSI.

  1. The Research Progress of the Liquid Scintillation Detectors on Neutron Measurement

    Institute of Scientific and Technical Information of China (English)

    CHENG; Yi-mei; XU; Xiao-ming; ZHU; Li-qun; BAI; Lei; XU; Zhen; HE; Li-xia; YIN; Hong-he

    2012-01-01

    <正>The research for liquid scintillation detectors on neutron measurement is one of the study objects of technique research on neutron measurement. According to the task requirements, we accomplished the purchase of some detectors and related performance testing. The purchased liquid scintillation detectors BC-501A is produced by Saint-Gobain Company. According to the formulated performance testing outlines for liquid scintillation detectors, we conducted

  2. A Directional Gamma-Ray Detector Based on Scintillator Plates

    CERN Document Server

    Hanna, D; Boyle, P; MacLeod, A M L

    2015-01-01

    A simple device for determining the azimuthal location of a source of gamma radiation, using ideas from astrophysical gamma-ray burst detection, is described. A compact and robust detector built from eight identical modules, each comprising a plate of CsI(Tl) scintillator coupled to a photomultiplier tube, can locate a point source of gamma rays with degree-scale precision by comparing the count rates in the different modules. Sensitivity to uniform environmental background is minimal.

  3. Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomograph

    CERN Document Server

    Moskal, P; Alfs, D; Bednarski, T; Białas, P; Czerwiński, E; Gajos, A; Giergiel, K; Gorgol, M; Jasińska, B; Kamińska, D; Kapłon, Ł; Korcyl, G; Kowalski, P; Kozik, T; Krzemień, W; Kubicz, E; Niedźwiecki, Sz; Pałka, M; Raczyński, L; Rudy, Z; Sharma, N G; Słomski, A; Silarski, M; Strzelecki, A; Wieczorek, A; Wiślicki, W; Witkowski, P; Zieliński, M; Zoń, N

    2016-01-01

    Recent tests of a single module of the Jagiellonian Positron Emission Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips have proven its applicability for the detection of annihilation quanta (0.511 MeV) with a coincidence resolving time (CRT) of 0.266 ns. The achieved resolution is almost by a factor of two better with respect to the current TOF-PET detectors and it can still be improved since, as it is shown in this article, the intrinsic limit of time resolution for the determination of time of the interaction of 0.511 MeV gamma quanta in plastic scintillators is much lower. As the major point of the article, a method allowing to record timestamps of several photons, at two ends of the scintillator strip, by means of matrix of silicon photomultipliers (SiPM) is introduced. As a result of simulations, conducted with the number of SiPM varying from 4 to 42, it is shown that the improvement of timing resolution saturates with the growing number of photomultipliers, and that the 2 x...

  4. Neutron irradiation and damage assessment of plastic scintillators of the Tile Calorimeter

    Science.gov (United States)

    Mdhluli, J. E.; Mellado, B.; Sideras-Haddad, E.

    2017-01-01

    Following the comparative study of proton induced radiation damage on various plastic scintillator samples from the ATLAS-CERN detector, a study on neutron irradiation and damage assessment on the same type of samples will be conducted. The samples will be irradiated with different dose rates of neutrons produced in favourable nuclear reactions using a radiofrequency linear particle accelerator as well as from the SAFARI nuclear reactor at NECSA. The MCNP 5 code will be utilized in simulating the neutron transport for determining the dose rate. Light transmission and light yield tests will be performed in order to assess the radiation damage on the scintillators. In addition, Raman spectroscopy and Electron Paramagnetic Resonance (EPR) analysis will be used to characterize the samples after irradiation. The project aims to extent these studies to include radiation assessment damage of any component that processes the scintillating light and deteriorates the quantum efficiency of the Tilecal detector, namely, photomultiplier tubes, wavelength shifting optical fibres and the readout electronics. They will also be exposed to neutron irradiation and the damage assessed in the same manner.

  5. Ion radiation damage in plastic detectors

    Energy Technology Data Exchange (ETDEWEB)

    Balcazar, M

    2006-07-01

    Plastic detectors are widely used for particle identification, micro pore and nano pore technology, neutron, gamma, radon and electron dosimeters. For some applications, plastic detectors have unique advantages among electronic detectors as 4 solid angles for ion identification in nuclear and cosmic ray physics; low-cost for massive use in indoors radon and neutron dosimeters; wide dose-range response for gamma and electron dosimetry; easy to use detectors in active geological faults in prospecting geothermal energy etc. There is a grate diversity of plastic detectors, which further improves their use in a particular application. However, the comparison test between different kinds of plastics can be time consuming, being therefore necessary to have methods for rapidly assessing plastic detectors properties. This invited talk deals in the first part with overview applications in Mexico of plastic detectors mentioned in the first paragraph. In the second part presents a general experimental relationship between the diameter-grow of positive ions tracks in several plastics for light ions, that allow to compare their energy resolution and to predict the track diameter of isotopes beams, as well as to predict the uniformity of micro pores. The formation of Nano pores produced by {sup 238} U ions is also discussed. (Author)

  6. Measurement of gamma quantum interaction point in plastic scintillator with WLS strips

    Science.gov (United States)

    Smyrski, J.; Alfs, D.; Bednarski, T.; Białas, P.; Czerwiński, E.; Dulski, K.; Gajos, A.; Głowacz, B.; Gupta-Sharma, N.; Gorgol, M.; Jasińska, B.; Kajetanowicz, M.; Kamińska, D.; Korcyl, G.; Kowalski, P.; Krzemień, W.; Krawczyk, N.; Kubicz, E.; Mohammed, M.; Niedźwiecki, Sz.; Pawlik-Niedźwiecka, M.; Raczyński, L.; Rudy, Z.; Salabura, P.; Silarski, M.; Strzelecki, A.; Wieczorek, A.; Wiślicki, W.; Wojnarska, J.; Zgardzińska, B.; Zieliński, M.; Moskal, P.

    2017-04-01

    The feasibility of measuring the aśxial coordinate of a gamma quantum interaction point in a plastic scintillator bar via the detection of scintillation photons escaping from the scintillator with an array of wavelength-shifting (WLS) strips is demonstrated. Using a test set-up comprising a BC-420 scintillator bar and an array of sixteen BC-482A WLS strips we achieved a spatial resolution of 5 mm (σ) for annihilation photons from a 22Na isotope. The studied method can be used to improve the spatial resolution of a plastic-scintillator-based PET scanner which is being developed by the J-PET collaboration.

  7. Review of plastic and liquid scintillation dosimetry for photon, electron, and proton therapy

    Science.gov (United States)

    Beaulieu, Luc; Beddar, Sam

    2016-10-01

    While scintillation dosimetry has been around for decades, the need for a dosimeter tailored to the reality of modern radiation therapy—in particular a real-time, water-equivalent, energy-independent dosimeter with high spatial resolution—has generated renewed interest in scintillators over the last 10 years. With the advent of at least one commercial plastic scintillation dosimeter and the ever-growing scientific literature on this subject, this topical review is intended to provide the medical physics community with a wide overview of scintillation physics, related optical concepts, and applications of plastic scintillation dosimetry.

  8. Neutron-gamma discrimination in elpasolite scintillator detector

    Science.gov (United States)

    Morgan, Brittany

    Existing nuclear stockpiles and weapons-making capabilities imperil the global community. Current nonproliferation efforts involve the research and development of newer, more efficient detection systems that can be deployed for the interdiction and monitoring of special nuclear materials (SNM). Spontaneous and induced fission events in SNM produce neutrons and gamma rays, which can be detected and analyzed, in particular, using scintillator detectors. Various electronic data acquisition systems and data analysis methods have been employed to record and characterize neutron and photon signatures. The goal of this thesis is to develop a new method of discrimination between neutrons and photons in the CLYC elpasolite scintillator detector. Because neutrons and photons interact uniquely with scintillator materials, they generate scintillation light decay signals of different time profiles. Several conventional and digital pulse shape discrimination (PSD) methods exist to exploit the different features of detector signal waveforms caused by the different time profiles of the scintillation decay. They can be categorized on the basis of their implementation: time domain only or time and frequency domain. In this study, wavelet analysis is implemented in the time domain. When the discrete wavelet transform is applied to each pulse, the Haar wavelet is sampled over the signal to generate a set of coefficients, which are then further analyzed using numerical integration. The wavelet-based signal analysis code was written in Matlab. The code processes a single detector waveform at a time. It first applies the discrete wavelet transform to smooth the waveform, and then calculates the power of this signal. After performing partial integrations on different parts of the coefficients' curve, it calculates the radiation identification (RID) value that serves as a threshold for neutron-gamma discrimination. Beyond the identifying threshold, the signal is categorized as a neutron

  9. Differentiation method for localization of Compton edge in organic scintillation detectors

    CERN Document Server

    Safari, M J; Afarideh, H

    2016-01-01

    This paper, presents a simple method for accurate calibration of organic scintillation detectors. The method is based on the fact that differentiating the response function leads to accurate estimation of the Compton edge. The differentiation method in addition to the location of the Compton edge, gives insights into the parameters of the folded Gaussian function which is useful for determination of the energy resolution. Moreover, it is observed that the uncorrelated noise in the measurement of the response function does not impose significant uncertainties in the evaluations. By simulation of the bounded electrons and considering the Doppler effects, we are able to calculate a first estimation for the intrinsic Doppler resolution of a plastic scintillator, benefiting from the capability of the differentiation method.

  10. Antineutrino Geophysics with Liquid Scintillator Detectors

    CERN Document Server

    Rothschild, C G; Calaprice, F P; Rothschild, Casey G.; Chen, Mark C.; Calaprice, Frank P.

    1997-01-01

    Detecting the antineutrinos emitted by the decay of radioactive elements in the mantle and crust could provide a direct measurement of the total abundance of uranium and thorium in the Earth. In calculating the antineutrino flux at specific sites, the local geology of the crust and the background from the world's nuclear power reactors are important considerations. Employing a global crustal map, with type and thickness data, and using recent estimates of the uranium and thorium distribution in the Earth, we calculate the antineutrino event rate for two new neutrino detectors. We show that spectral features allow terrestrial antineutrino events to be identified above reactor antineutrino backgrounds and that the uranium and thorium contributions can be separately determined.

  11. Quenching Factor for Low Energy Nuclear Recoils in a Plastic Scintillator

    OpenAIRE

    Reichhart, L.; Akimov, D. Yu.; Araujo, H. M.; Barnes, E. J.; Belov, V. A.; Burenkov, A. A.; Chepel, V.; Currie, A; DeViveiros, L.; Edwards, B.; Francis, V.; Ghag, C.; Hollingsworth, A.; Horn, M.; Kalmus, G.E.

    2011-01-01

    Plastic scintillators are widely used in industry, medicine and scientific research, including nuclear and particle physics. Although one of their most common applications is in neutron detection, experimental data on their response to low-energy nuclear recoils are scarce. Here, the relative scintillation efficiency for neutron-induced nuclear recoils in a polystyrene-based plastic scintillator (UPS-923A) is presented, exploring recoil energies between 125 keV and 850 keV. Monte Carlo simula...

  12. Organic liquid scintillation detector shape and volume impact on radiation portal monitors

    Science.gov (United States)

    Paff, Marc G.; Clarke, Shaun D.; Pozzi, Sara A.

    2016-07-01

    We have developed and tested a radiation portal monitor using organic liquid scintillation detectors. In order to optimize our system designs, neutron measurements were carried out with three organic liquid scintillation detectors of different shapes and sizes, along with a 3He radiation portal monitor (RPM) as a reference. The three liquids tested were a 7.62 cm diameter by 7.62 cm length cylindrical active volume organic liquid scintillation detector, a 12.7 cm diameter by 12.7 cm length cylindrical active volume organic liquid scintillation detector, and a 25 cm by 25 cm by 10 cm "paddle" shaped organic liquid scintillation detector. Background and Cf-252 neutron measurements were recorded to allow for a comparison of neutron intrinsic efficiencies as well as receiver operating characteristics (ROC) curves between detectors. The 12.7 cm diameter cylindrical active volume organic liquid scintillation detector exhibited the highest intrinsic neutron efficiency (54%) of all three liquid scintillators. An ROC curve analysis for a heavily moderated Cf-252 measurement showed that using the 12.7 cm diameter by 12.7 cm length cylindrical active volume Eljen EJ309 organic liquid scintillation detector would result in the fewest needed detector units in order to achieve a near 100% positive neutron alarm rate while maintaining a better than 1 in 10,000 false alarm rate on natural neutron background. A small number of organic liquid scintillation detectors could therefore be a valid alternative to 3He in some RPM applications.

  13. Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomograph

    Science.gov (United States)

    Moskal, P.; Rundel, O.; Alfs, D.; Bednarski, T.; Białas, P.; Czerwiński, E.; Gajos, A.; Giergiel, K.; Gorgol, M.; Jasińska, B.; Kamińska, D.; Kapłon, Ł.; Korcyl, G.; Kowalski, P.; Kozik, T.; Krzemień, W.; Kubicz, E.; Niedźwiecki, Sz; Pałka, M.; Raczyński, L.; Rudy, Z.; Sharma, N. G.; Słomski, A.; Silarski, M.; Strzelecki, A.; Wieczorek, A.; Wiślicki, W.; Witkowski, P.; Zieliński, M.; Zoń, N.

    2016-03-01

    Recent tests of a single module of the Jagiellonian Positron Emission Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips have proven its applicability for the detection of annihilation quanta (0.511 MeV) with a coincidence resolving time (CRT) of 0.266 ns. The achieved resolution is almost by a factor of two better with respect to the current TOF-PET detectors and it can still be improved since, as it is shown in this article, the intrinsic limit of time resolution for the determination of time of the interaction of 0.511 MeV gamma quanta in plastic scintillators is much lower. As the major point of the article, a method allowing to record timestamps of several photons, at two ends of the scintillator strip, by means of matrix of silicon photomultipliers (SiPM) is introduced. As a result of simulations, conducted with the number of SiPM varying from 4 to 42, it is shown that the improvement of timing resolution saturates with the growing number of photomultipliers, and that the 2× 5 configuration at two ends allowing to read twenty timestamps, constitutes an optimal solution. The conducted simulations accounted for the emission time distribution, photon transport and absorption inside the scintillator, as well as quantum efficiency and transit time spread of photosensors, and were checked based on the experimental results. Application of the 2× 5 matrix of SiPM allows for achieving the coincidence resolving time in positron emission tomography of ≈ 0.170 ns for 15 cm axial field-of-view (AFOV) and ≈ 0.365 ns for 100 cm AFOV. The results open perspectives for construction of a cost-effective TOF-PET scanner with significantly better TOF resolution and larger AFOV with respect to the current TOF-PET modalities.

  14. A new anti-neutrino detection technique based on positronium tagging with plastic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Consolati, G. [Department of Aerospace Science and Technology, Politecnico di Milano, via La Masa 34, 20156 Milano (Italy); Franco, D., E-mail: dfranco@in2p3.fr [APC, Univ. Paris Diderot, CNRS/IN2P3, CEA/Irfu, Obs. de Paris, Sorbonne Paris Cité, 75205 Paris (France); Jollet, C. [IPHC, Université de Strasbourg, CNRS/IN2P3, 67037 Strasbourg (France); Meregaglia, A., E-mail: amerega@in2p3.fr [IPHC, Université de Strasbourg, CNRS/IN2P3, 67037 Strasbourg (France); Minotti, A. [IPHC, Université de Strasbourg, CNRS/IN2P3, 67037 Strasbourg (France); Perasso, S.; Tonazzo, A. [APC, Univ. Paris Diderot, CNRS/IN2P3, CEA/Irfu, Obs. de Paris, Sorbonne Paris Cité, 75205 Paris (France)

    2015-09-21

    The main signature for anti-neutrino detection in reactor and geo-neutrino experiments based on scintillators is provided by the space–time coincidence of positron and neutron produced in the Inverse Beta Decay reaction. Such a signature strongly suppresses backgrounds and allows for measurements performed underground with a relatively high signal-to-background ratio. In an aboveground environment, however, the twofold coincidence technique is not sufficient to efficiently reject the high background rate induced by cosmogenic events. Enhancing the positron–neutron twofold coincidence efficiency may pave the way to future aboveground detectors for reactor monitoring. We propose a new detection scheme based on a threefold coincidence, among the positron ionization, the ortho-positronium (o-Ps) decay, and the neutron capture, in a sandwich detector with alternated layers of plastic scintillator and aerogel powder. We present the results of a set of dedicated measurements on the achievable light yield and on the o-Ps formation and lifetime. The efficiencies for signal detection and background rejection of a preliminary detector design are also discussed.

  15. Development of SiPM-based scintillator tile detectors for a multi-layer fast neutron tracker

    Directory of Open Access Journals (Sweden)

    Jakubek J.

    2012-10-01

    Full Text Available We are developing thin tile scintillator detectors with silicon photomultiplier (SiPM readout for use in a multi-layer fast-neutron tracker. The tracker is based on interleaved Timepix and plastic scintillator layers. The thin 15 × 15 × 2 mm plastic scintillators require suitable optical readout in order to detect and measure the energy lost by energetic protons that have been recoiled by fast neutrons. Our first prototype used dual SiPMs, coupled to opposite edges of the scintillator tile using light-guides. An alternative readout geometry was designed in an effort to increase the fraction of scintillation light detected by the SiPMs. The new prototype uses a larger SiPM array to cover the entire top face of the tile. This paper details the comparative performance of the two prototype designs. A deuterium-tritium (DT fast-neutron source was used to compare the relative light collection efficiency of the two designs. A collimated UV light source was scanned across the detector face to map the uniformity. The new prototype was found to have 9.5 times better light collection efficiency over the original design. Both prototypes exhibit spatial non-uniformity in their response. Methods of correcting this non-uniformity are discussed.

  16. Emulation workbench for position sensitive gaseous scintillation detectors

    CERN Document Server

    Pereira, L; Morozov, A; Solovov, V; Fraga, F A F

    2015-01-01

    Position sensitive detectors based on gaseous scintillation proportional counters with Anger-type readout are being used in several research areas such as neutron detection, search for dark matter and neutrinoless double beta decay. Design and optimization of such detectors are complex and time consuming tasks. Simulations, while being a powerful tool, strongly depend on the light transport models and demand accurate knowledge of many parameters, which are often not available. Here we describe an alternative approach based on the experimental evaluation of a detector using an isotropic point-like light source with precisely controllable light emission properties, installed on a 3D positioning system. The results obtained with the developed setup at validation conditions, when the scattered light is strongly suppressed, show good agreement with simulations.

  17. Emulation workbench for position sensitive gaseous scintillation detectors

    Science.gov (United States)

    Pereira, L.; Margato, L. M. S.; Morozov, A.; Solovov, V.; Fraga, F. A. F.

    2015-12-01

    Position sensitive detectors based on gaseous scintillation proportional counters with Anger-type readout are being used in several research areas such as neutron detection, search for dark matter and neutrinoless double beta decay. Design and optimization of such detectors are complex and time consuming tasks. Simulations, while being a powerful tool, strongly depend on the light transfer models and demand accurate knowledge of many parameters, which are often not available. Here we describe an alternative approach based on the experimental evaluation of a detector using an isotropic point-like light source with precisely controllable light emission properties, installed on a 3D positioning system. The results obtained with the developed setup at validation conditions, when the scattered light is strongly suppressed show good agreement with simulations.

  18. Neutron response function characterization of {sup 4}He scintillation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Kelley, Ryan P.; Rolison, Lucas M.; Lewis, Jason M. [University of Florida, Nuclear Engineering Program, Gainesville, FL 32611-6400 (United States); Murer, David [Arktis Radiation Detectors Ltd., Räffelstrasse 11, 8045 Zürich (Switzerland); Massey, Thomas N. [Ohio University, Institute of Nuclear and Particle Physics, Athens, OH 45701 (United States); Enqvist, Andreas; Jordan, Kelly A. [University of Florida, Nuclear Engineering Program, Gainesville, FL 32611-6400 (United States)

    2015-09-01

    Time-of-flight measurements were conducted to characterize the neutron energy response of pressurized {sup 4}He fast neutron scintillation detectors for the first time, using the Van de Graaff generator at Ohio University. The time-of-flight spectra and pulse height distributions were measured. This data was used to determine the light output response function, which was found to be linear at energies below 3.5 MeV. The intrinsic efficiency of the detector as a function of incident energy was also calculated: the average efficiency up to 10 MeV was 3.1%, with a maximum efficiency of 6.6% at 1.05 MeV. These results will enable development of neutron spectrum unfolding algorithms for neutron spectroscopy applications with these detectors.

  19. TH-C-19A-10: Systematic Evaluation of Photodetectors Performances for Plastic Scintillation Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Boivin, J; Beaulieu, L [University Laval, Quebec, QC (Canada); Centre Hospitalier University de Quebec, Quebec, QC (Canada); Beddar, S [University of Texas MD Anderson Cancer Center, Houston, TX (United States); Guillemette, M [Institut Universitaire de Cardiologie et de Pneumologie de Quebec, Quebec, QC (Canada)

    2014-06-15

    Purpose: To assess and compare the performance of different photodetectors likely to be used in a plastic scintillation detector (PSD). Methods: The PSD consists of a 1 mm diameter, 10 mm long plastic scintillation fiber (BCF-60) which is optically coupled to a clear 10 m long optical fiber of the same diameter. A light-tight plastic sheath covers both fibers and the scintillator end is sealed. The clear fiber end is connected to one of the following six studied photodetectors: two polychromatic cameras (one with an optical lens and one with a fiber optic taper replacing the lens); a monochromatic camera with the same optical lens; a PIN photodiode; an avalanche photodiode (APD); and a photomultiplier tube (PMT). Each PSD is exposed to both low energy beams (120, 180, and 220 kVp) from an orthovoltage unit, and high energy beams (6 MV and 23 MV) from a linear accelerator. Various dose rates are explored to identify the photodetectors operating ranges and accuracy. Results: For all photodetectors, the relative uncertainty remains under 5 % for dose rates over 3 mGy/s. The taper camera collects four times more signal than the optical lens camera, although its standard deviation is higher since it could not be cooled. The PIN, APD and PMT have higher sensitivity, suitable for low dose rate and out-of-field dose monitoring. PMT's relative uncertainty remains under 1 % at the lowest dose rate achievable (50 μGy/s), suggesting optimal use for live dosimetry. Conclusion: A set of 6 photodetectors have been studied over a broad dose rate range at various energies. For dose rate above 3 mGy/s, the PIN diode is the most effective photodetector in term of performance/cost ratio. For lower dose rate, such as those seen in interventional radiology, PMTs are the optimal choice. FQRNT Doctoral Research Scholarship.

  20. Polycrystalline scintillators for large area detectors in HEP experiments

    Science.gov (United States)

    Dosovitskiy, G.; Fedorov, A.; Karpyuk, P.; Kuznetsova, D.; Mikhlin, A.; Kozlov, D.; Dosovitskiy, A.; Korjik, M.

    2017-06-01

    After significant increase of the accelerator luminosity throughout the High Luminosity phase of LHC, charged hadrons and neutrons with fluences higher than 1014 p/cm2 per year in the largest pseudo-rapidity regions of the detectors will cause increased radiation damage of materials. Increasing activation of the experimental equipment will make periodical maintenance and replacement of detector components difficult. Therefore, the selected materials for new detectors should be tolerant to radiation damage. Y3Al5O12:Ce (YAG:Ce) crystal was found to be one of the most radiation hard scintillation materials. However, production of YAG:Ce in a single crystalline form is costly, because crystal growth is performed at temperature near 1900°C with a very low rate of transformation of a raw material into a crystal. We propose translucent YAG:Ce ceramics as an alternative cheaper solution. Ceramic samples were sintered up to density ~98% of the theoretical value and were translucent. The samples have demonstrated light yield of 2200 phot./MeV under 662 keV γ-quanta, which gives the expected response to minimum ionizing particle around 3000 phot. for 2 mm thick plate. Scintillation light yield, registered under surface layer excitation with α-particles, was 50-70% higher than for the reference single crystal YAG:Ce.

  1. Optimizing ZnS/6LiF scintillators for wavelength-shifting-fiber neutron detectors

    Energy Technology Data Exchange (ETDEWEB)

    Crow, Lowell [ORNL; Funk, Loren L [ORNL; Hannan, Bruce W [ORNL; Hodges, Jason P [ORNL; Riedel, Richard A [ORNL; Wang, Cai-Lin [ORNL

    2016-01-01

    In this paper we compare the performance of grooved and flat ZnS/6LiF scintillators in a wavelength shifting-fiber (WLSF) detector. Flat ZnS/6LiF scintillators with the thickness L=0.2-0.8 mm were characterized using photon counting and pulse-height analysis and compared to a grooved scintillator of approximately 0.8 mm thick. While a grooved scintillator considerably increases the apparent thickness of the scintillator to neutrons for a given coating thickness, we find that the flat scintillators perform better than the grooved scintillators in terms of both light yield and neutron detection efficiency. The flat 0.8-mm-thick scintillator has the highest light output, and it is 52% higher compared with a grooved scintillator of same thickness. The lower light output of the grooved scintillator as compared to the flat scintillator is consistent with the greater scintillator-WLSF separation and the much larger average emission angle of the grooved scintillator. We also find that the average light cone width, or photon travel-length as measured using time-of-flight powder diffraction of diamond and vanadium, decreases with increasing L in the range of L=0.6-0.8 mm. This result contrasts with the traditional Swank diffusion model for micro-composite scintillators, and could be explained by a decrease in photon diffusion-coefficient or an increase in micro-particle content in the flat scintillator matrix for the thicker scintillators.

  2. {sup 6}Li foil scintillation sandwich thermal neutron detector

    Energy Technology Data Exchange (ETDEWEB)

    Ianakiev, K.D., E-mail: ianakiev@lanl.gov [Los Alamos National Laboratory, MS E540, Los Alamos, NM 87545 (United States); Swinhoe, M.T.; Favalli, A.; Chung, K.; MacArthur, D.W. [Los Alamos National Laboratory, MS E540, Los Alamos, NM 87545 (United States)

    2011-10-01

    Increasing needs for neutron detection and limited supply of {sup 3}He have led to the need for replacement neutron detection technology. This paper presents the design and initial results for a neutron detector ({sup 6}Li foil scintillator sandwich) that uses lithium metal foil to detect thermal neutrons. The reaction products, primarily triton, deposit most of their energy in thin scintillator films and create light pulses. Gamma rays can deposit only a small amount of energy in the thin films and so produce only very small light pulses. Lithium is preferable to boron in this application because triton escapes from lithium more easily than does the alpha particle from boron, allowing the use of thicker films and hence greater efficiency. In addition, triton has a higher light output in the scintillator than the boron alpha particle. Lithium metal is preferable to a lithium compound, such as lithium fluoride, because the number of tritons that escape from the metal is greater for the same amount of lithium. Monte Carlo simulations show that good efficiency values can be achieved with reasonably sized detectors, values that are greater than that of comparable {sup 3}He systems for portal monitors. In addition, simulations of a neutron coincidence counting concept show high counting efficiency and short die-away time (16 {mu}s), which imply better performance than that of the high-level neutron coincidence counter (HLNCC)-II. Initial experimental measurements on a prototype detector using alpha particles (having similar light output to the expected tritons) show good light collection and transport properties.

  3. Characterization of scintillating plastic fibers and silicon photomultipliers for their usage in a particle telescope

    Energy Technology Data Exchange (ETDEWEB)

    Pruefer, Lea; Losekamm, Martin; Poeschl, Thomas; Greenwald, Daniel; Paul, Stephan [Technische Universitaet Muenchen, 85748 Garching (Germany)

    2016-07-01

    The Multi-purpose Active-target Particle Telescope (MAPT) is a newly developed compact charged-particle detector. It can be used for space applications, such as radiation monitoring on spacecraft or for stratospheric research balloons. Its core consists of scintillating plastic fibers coupled to silicon photomultiplier (SiPMs). The energy reconstruction of the incoming particles is based on an extended Bragg curve spectroscopy technique, requiring a good measurement of the energy deposition. Therefore, non-linearities of the measured light output -such as quenching effects of the scintillating material or saturation of the SiPMs at high light yields- have to be known quantitatively. To investigate these effects, two scaled-down prototypes were built, consisting of 128 and 16 channels. The first one was tested at a stationary proton beam at Paul Scherrer Institute. We determine Birk's coefficient describing the ionization quenching of the scintillator and calculate the characteristic photon detection efficiency of the SiPMs. We explain the results of the first prototype tests and the characterization of the SiPMs.

  4. Atmospheric Neutron Measurements using a Small Scintillator Based Detector

    Science.gov (United States)

    Kole, Merlin; Pearce, Mark; Fukazawa, Yasushi; Fukuda, Kentaro; Ishizu, Sumito; Jackson, Miranda; Kamae, Tune; Kawaguchi, Noriaki; Kawano, Takafumi; Kiss, Mozsi; Moretti, Elena; Yanagida, Takayuki; Chauvin, Maxime; Mikhalev, Victor; Rydstrom, Stefan; Takahashi, Hiromitsu

    PoGOLino is a standalone scintillator-based neutron detector designed for balloon-borne missions. Its main purpose is to provide data of the neutron flux in 2 different energy ranges in the high altitude / high latitude region where the highest neutron flux in the atmosphere is found. Furthermore the influence of the Solar activity upon the neutron environment in this region is relatively strong. As a result both short and long term time fluctuations are strongest in this region. At high altitudes neutrons can form a source of background for balloon-borne scientific measurements. They can furthermore form a major source for single event upsets in electronics. A good understanding of the high altitude / high latitude neutron environment is therefore important. Measurements of the neutron environment in this region are however lacking. PoGOLino contains two 5 mm thick Lithium Calcium Aluminium Fluoride (LiCAF) scintillators used for neutron detection. The LiCAF crystals are sandwiched between 2 Bismuth Germanium Oxide (BGO) scintillating crystals, which serve to veto signals produced by gamma-rays and charged particles. The veto system makes measurements of the neutron flux possible even in high radiation environments. One LiCAF detector is shielded with polyethylene while the second remains unshielded, making the detectors sensitive in different energy ranges. The choice of a scintillator crystals as the detection material ensures a high detection efficiency while keeping the instrument small, robust and light weight. The full standalone cylindrical instrument has a radius of 120 mm, a height of 670 mm and a total mass of 13 kg, making it suitable as a piggy back mission. PoGOLino was successfully launched on March 20th 2013 from the Esrange Space Center in Northern Sweden to an altitude of 30.9 km. A detailed description of the detector design is presented, along with results of of the flight. The neutron flux measured during flight is compared to predictions based

  5. A liquid scintillator detector with wavelength-shifting fibre readout

    CERN Document Server

    Doucet, M; Grégoire, G; Panman, J; Zucchelli, P

    2000-01-01

    A technique based on liquid scintillator with wavelength-shiftingfibre readout is interesting for large-mass neutrino detectors.In this paper we present the first results obtained with a laboratoryprototype assembled at CERN. In the configuration tested, a large light yield has been observed and attenuation lengths of the order of 3.2~m have been measured. As a comparison, we also measured the attenuation length of the fibres in air using the same setup. No significant difference in attenuation length between the fibres in air and in liquid was measured.

  6. The Seeding tracking algorithm for a scintillating detector at LHCb

    CERN Document Server

    Amhis, Y; De Cian, M; Nikodem, T; Polci, F

    2014-01-01

    The project of the LHCb upgraded detector foreseens the presence of a Scintillating Fiber Tracker (SciFi). This note describes the algorithm used for reconstructing standalone tracks in the SciFi, called $Seeding$. This algorithm is crucial for reconstructing tracks generated by long lived particles such as $K^0_s$. The main performances on simulated samples for running conditions expected in future data taking after the upgrade, namely a luminosity larger than $\\mathcal{L} = 2 \\times 10^{33} cm^{-2}s^{1}$, are also discussed.

  7. Triton burnup study using scintillating fiber detector on JT-60U

    Energy Technology Data Exchange (ETDEWEB)

    Harano, Hideki [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment

    1997-09-01

    The DT fusion reactor cannot be realized without knowing how the fusion-produced 3.5 MeV {alpha} particles behave. The {alpha} particles` behavior can be simulated using the 1 MeV triton. To investigate the 1 MeV triton`s behavior, a new type of directional 14 MeV neutron detector, scintillating fiber (Sci-Fi) detector has been developed and installed on JT-60U in the cooperation with LANL as part of a US-Japan collaboration. The most remarkable feature of the Sci-Fi detector is that the plastic scintillating fibers are employed for the neutron sensor head. The Sci-Fi detector measures and extracts the DT neutrons from the fusion radiation field in high time resolution (10 ms) and wide dynamic range (3 decades). Triton burnup analysis code TBURN has been made in order to analyze the time evolution of DT neutron emission rate obtained by the Sci-Fi detector. The TBURN calculations reproduced the measurements fairly well, and the validity of the calculation model that the slowing down of the 1 MeV triton was classical was confirmed. The Sci-Fi detector`s directionality indicated the tendency that the DT neutron emission profile became more and more peaked with the time progress. In this study, in order to examine the effect of the toroidal field ripple on the triton burnup, R{sub p}-scan and n{sub e}-scan experiments have been performed. The R{sub p}-scan experiment indicates that the triton`s transport was increased as the ripple amplitude over the triton became larger. In the n{sub e}-scan experiment, the DT neutron emission showed the characteristic changes after the gas puffing injection. It was theoretically confirmed that the gas puffing was effective for the collisionality scan. (J.P.N.) 127 refs.

  8. Ruby-based inorganic scintillation detectors for 192Ir brachytherapy

    Science.gov (United States)

    Kertzscher, Gustavo; Beddar, Sam

    2016-11-01

    We tested the potential of ruby inorganic scintillation detectors (ISDs) for use in brachytherapy and investigated various unwanted luminescence properties that may compromise their accuracy. The ISDs were composed of a ruby crystal coupled to a poly(methyl methacrylate) fiber-optic cable and a charge-coupled device camera. The ISD also included a long-pass filter that was sandwiched between the ruby crystal and the fiber-optic cable. The long-pass filter prevented the Cerenkov and fluorescence background light (stem signal) induced in the fiber-optic cable from striking the ruby crystal, which generates unwanted photoluminescence rather than the desired radioluminescence. The relative contributions of the radioluminescence signal and the stem signal were quantified by exposing the ruby detectors to a high-dose-rate brachytherapy source. The photoluminescence signal was quantified by irradiating the fiber-optic cable with the detector volume shielded. Other experiments addressed time-dependent luminescence properties and compared the ISDs to commonly used organic scintillator detectors (BCF-12, BCF-60). When the brachytherapy source dwelled 0.5 cm away from the fiber-optic cable, the unwanted photoluminescence was reduced from  >5% to  5% within 10 s from the onset of irradiation and after the source had retracted. The ruby-based ISDs generated signals of up to 20 times that of BCF-12-based detectors. The study presents solutions to unwanted luminescence properties of ruby-based ISDs for high-dose-rate brachytherapy. An optic filter should be sandwiched between the ruby crystal and the fiber-optic cable to suppress the photoluminescence. Furthermore, we recommend avoiding ruby crystals that exhibit significant time-dependent luminescence.

  9. Scanners for the quality contol of scintillating plastic fibres

    CERN Document Server

    Rodigues, Ana Barbara; Garnier, Francois; Giudici, Pierre-Ange; Greim, Roman; Hebler, Philip; Joram, Christian; Kirn, Thomas; Pierschel, Gerhard; Schateikis, Tobias; Stevens, Holger; Bachlechner, Andreas; Deckenhoff, Mirco; Karpinski, Waclaw; Kruse, Florian; Schultz Von Dratzig, Arndt; Schwering, Georg; Swientek, Krzysztof Piotr; Wlochal, Michael

    2015-01-01

    The use of scintillating plastic fibres in the SciFi tracker requires rigorous quality control. The fibre diameter and in particular local variations in form of bumps and necks have an impact on the regularity of the winding pattern and hence the spatial resolution. Defects in the fibre cladding lead to light losses and inter-fibre cross talk. Machines have been developed which allow scanning at high throughput of the fibre diameter and the integrity of the cladding. We describe the design principles and implementations of these machines and illustrate their performance. While these machines allow to identify and quantify performance issues of the prototype fibres, they will also play a major role during the series production of the SciFi tracker. If needed, the capacity of the machines allows scanning of the full production volume.

  10. X-Ray Detector-on-Plastic with High Sensitivity Using Low Cost, Solution-Processed Organic Photodiodes

    NARCIS (Netherlands)

    Gelinck, G.H.; Kumar, A.; Moet, D.; Steen, J.L.P.J. van der; Breemen, A.J.J.M. van; Shanmugam, S.; Langen, A.; Gilot, J.; Groen, W.A.; Andriessen, H.A.J.M.; Simon, M.; Ruetten, W.; Douglas, A.U.; Raaijmakers, R.; Malinowski, P.E.; Myny, K.

    2016-01-01

    We made and characterized an X-ray detector on a 25-ìm-thick plastic substrate that is capable of medicalgrade performance. As an indirect conversion flat panel detector, it combined a standard scintillator with an organic photodetector (OPD) layer and oxide thin-film transistor backplane. Using sol

  11. X-Ray Detector-on-Plastic with High Sensitivity Using Low Cost, Solution-Processed Organic Photodiodes

    NARCIS (Netherlands)

    Gelinck, G.H.; Kumar, A.; Moet, D.; Steen, J.L.P.J. van der; Breemen, A.J.J.M. van; Shanmugam, S.; Langen, A.; Gilot, J.; Groen, W.A.; Andriessen, H.A.J.M.; Simon, M.; Ruetten, W.; Douglas, A.U.; Raaijmakers, R.; Malinowski, P.E.; Myny, K.

    2016-01-01

    We made and characterized an X-ray detector on a 25-ìm-thick plastic substrate that is capable of medicalgrade performance. As an indirect conversion flat panel detector, it combined a standard scintillator with an organic photodetector (OPD) layer and oxide thin-film transistor backplane. Using sol

  12. Modular design of long narrow scintillating cells for ILC detector

    Energy Technology Data Exchange (ETDEWEB)

    Beznosko, D.; Blazey, G.; Dyshkant, A.; Maloney, J.; Rykalin, V.; /Northern Illinois U.; Schellpfeffer, J.; /Fermilab

    2005-09-01

    The experimental results for the narrow scintillating elements with effective area about 20 cm{sup 2} are reported. The elements were formed from the single piece of scintillator and were read out via wavelength shifting fibers with the MRS (Metal/Resistor/Semiconductor) photodiodes on both ends of each fiber. The formation of the cells from the piece of scintillator by using grooves is discussed. The cell performance was tested using the radioactive source by measuring the PMT current and a single rate after amplifier and discrimination with threshold at about three photo electrons in each channel and quad coincidences (double coincidences between sensors on each fiber and double coincidences between two neighboring fibers). This result is of high importance for large multi-channel systems, i.e. module may be used as an active element for calorimeter or muon system for the design of the future electron-positron linear collider detector because cell effective area can be smoothly enlarged or reduced (to 4 cm{sup 2} definitely).

  13. Spatial distributions of photons in plastic scintillator detected by multi-anode photomultiplier for heavy-ion position determination

    Energy Technology Data Exchange (ETDEWEB)

    Omika, S. [Department of Physics, Saitama University, Saitama 338-8570 (Japan); Yamaguchi, T., E-mail: yamaguti@phy.saitama-u.ac.jp [Department of Physics, Saitama University, Saitama 338-8570 (Japan); Fukuda, M. [Department of Physics, Osaka University, Toyonaka, Osaka 560-0043 (Japan); Kitagawa, A. [National Institute of Radiological Sciences, Chiba 263-8555 (Japan); Matsunaga, S. [Department of Physics, Saitama University, Saitama 338-8570 (Japan); Nagae, D. [Institute of Physics, University of Tsukuba, Ibaraki 305-8571 (Japan); Nishimura, D. [Department of Physics, Tokyo University of Science, Noda 278-8510 (Japan); Nishimura, T. [Department of Physics, Saitama University, Saitama 338-8570 (Japan); Ozawa, A. [Institute of Physics, University of Tsukuba, Ibaraki 305-8571 (Japan); Sato, S. [National Institute of Radiological Sciences, Chiba 263-8555 (Japan); Sawahata, K. [Institute of Physics, University of Tsukuba, Ibaraki 305-8571 (Japan); Suzuki, T.; Takeuchi, Y. [Department of Physics, Saitama University, Saitama 338-8570 (Japan)

    2015-10-11

    The spatial distributions of scintillation photons in a plastic scintillation detector were measured using a multi-anode photomultiplier H7546A coupled with 1-mm-diameter optical fibers. A row of several tens of fibers connected to the scintillator generates one-dimensional spatial distributions of photons induced by the swift passage of heavy ions. The pulse heights from each channel change depending on the beam position. This can be utilized to determine the positions of the heavy ions. To test the performance of the proposed detection method, an experiment using a {sup 84}Kr beam with intermediate energies ranging from 40 to 85 MeV/nucleon was performed at the heavy-ion medical accelerator in Chiba (HIMAC). The photon spatial distributions were successfully observed. By optimizing the photomultiplier bias voltage and threshold in the pulse height analyses, a detection efficiency of 98% and a position resolution of 1.1 mm in σ were achieved simultaneously.

  14. A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Kaminska, D.; Gajos, A.; Czerwinski, E.; Alfs, D.; Bednarski, T.; Bialas, P.; Dulski, K.; Glowacz, B.; Gupta-Sharma, N.; Korcyl, G.; Krawczyk, N.; Kubicz, E.; Mohammed, M.; Niedzwiecki, Sz.; Pawlik-Niedzwiecka, M.; Rudy, Z.; Wieczorek, A.; Zielinski, M.; Moskal, P. [Jagiellonian University, Faculty of Physics, Astronomy and Applied Computer Science, Krakow (Poland); Curceanu, C.; Silarski, M. [INFN, Laboratori Nazionali di Frascati, CP 13, Frascati (Italy); Gorgol, M.; Jasinska, B.; Zgardzinska, B. [Maria Curie-Sklodowska University, Department of Nuclear Methods, Institute of Physics, Lublin (Poland); Hiesmayr, B.C. [University of Vienna, Faculty of Physics, Vienna (Austria); Kowalski, P.; Raczynski, L.; Wislicki, W. [Swierk Computing Centre, National Centre for Nuclear Research, Otwock-Swierk (Poland); Krzemien, W. [National Centre for Nuclear Research, High Energy Department, Otwock-Swierk (Poland)

    2016-08-15

    We present a study of the application of the Jagiellonian positron emission tomograph (J-PET) for the registration of gamma quanta from decays of ortho-positronium (o-Ps). The J-PET is the first positron emission tomography scanner based on organic scintillators in contrast to all current PET scanners based on inorganic crystals. Monte Carlo simulations show that the J-PET as an axially symmetric and high acceptance scanner can be used as a multi-purpose detector well suited to pursue research including e.g. tests of discrete symmetries in decays of ortho-positronium in addition to the medical imaging. The gamma quanta originating from o-Ps decay interact in the plastic scintillators predominantly via the Compton effect, making the direct measurement of their energy impossible. Nevertheless, it is shown in this paper that the J-PET scanner will enable studies of the o-Ps → 3γ decays with angular and energy resolution equal to σ(θ) ∼ 0.4 {sup circle} and σ(E) ∼ 4.1 keV, respectively. An order of magnitude shorter decay time of signals from plastic scintillators with respect to the inorganic crystals results not only in better timing properties crucial for the reduction of physical and instrumental background, but also suppresses significantly the pile-ups, thus enabling compensation of the lower efficiency of the plastic scintillators by performing measurements with higher positron source activities. (orig.)

  15. A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators

    Science.gov (United States)

    Kamińska, D.; Gajos, A.; Czerwiński, E.; Alfs, D.; Bednarski, T.; Białas, P.; Curceanu, C.; Dulski, K.; Głowacz, B.; Gupta-Sharma, N.; Gorgol, M.; Hiesmayr, B. C.; Jasińska, B.; Korcyl, G.; Kowalski, P.; Krzemień, W.; Krawczyk, N.; Kubicz, E.; Mohammed, M.; Niedźwiecki, Sz.; Pawlik-Niedźwiecka, M.; Raczyński, L.; Rudy, Z.; Silarski, M.; Wieczorek, A.; Wiślicki, W.; Zgardzińska, B.; Zieliński, M.; Moskal, P.

    2016-08-01

    We present a study of the application of the Jagiellonian positron emission tomograph (J-PET) for the registration of gamma quanta from decays of ortho-positronium (o-Ps). The J-PET is the first positron emission tomography scanner based on organic scintillators in contrast to all current PET scanners based on inorganic crystals. Monte Carlo simulations show that the J-PET as an axially symmetric and high acceptance scanner can be used as a multi-purpose detector well suited to pursue research including e.g. tests of discrete symmetries in decays of ortho-positronium in addition to the medical imaging. The gamma quanta originating from o-Ps decay interact in the plastic scintillators predominantly via the Compton effect, making the direct measurement of their energy impossible. Nevertheless, it is shown in this paper that the J-PET scanner will enable studies of the { o-Ps }→ 3γ decays with angular and energy resolution equal to σ (θ ) ≈ {0.4°} and σ (E) ≈ 4.1 {keV}, respectively. An order of magnitude shorter decay time of signals from plastic scintillators with respect to the inorganic crystals results not only in better timing properties crucial for the reduction of physical and instrumental background, but also suppresses significantly the pile-ups, thus enabling compensation of the lower efficiency of the plastic scintillators by performing measurements with higher positron source activities.

  16. A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators.

    Science.gov (United States)

    Kamińska, D; Gajos, A; Czerwiński, E; Alfs, D; Bednarski, T; Białas, P; Curceanu, C; Dulski, K; Głowacz, B; Gupta-Sharma, N; Gorgol, M; Hiesmayr, B C; Jasińska, B; Korcyl, G; Kowalski, P; Krzemień, W; Krawczyk, N; Kubicz, E; Mohammed, M; Niedźwiecki, Sz; Pawlik-Niedźwiecka, M; Raczyński, L; Rudy, Z; Silarski, M; Wieczorek, A; Wiślicki, W; Zgardzińska, B; Zieliński, M; Moskal, P

    We present a study of the application of the Jagiellonian positron emission tomograph (J-PET) for the registration of gamma quanta from decays of ortho-positronium (o-Ps). The J-PET is the first positron emission tomography scanner based on organic scintillators in contrast to all current PET scanners based on inorganic crystals. Monte Carlo simulations show that the J-PET as an axially symmetric and high acceptance scanner can be used as a multi-purpose detector well suited to pursue research including e.g. tests of discrete symmetries in decays of ortho-positronium in addition to the medical imaging. The gamma quanta originating from o-Ps decay interact in the plastic scintillators predominantly via the Compton effect, making the direct measurement of their energy impossible. Nevertheless, it is shown in this paper that the J-PET scanner will enable studies of the [Formula: see text] decays with angular and energy resolution equal to [Formula: see text] and [Formula: see text], respectively. An order of magnitude shorter decay time of signals from plastic scintillators with respect to the inorganic crystals results not only in better timing properties crucial for the reduction of physical and instrumental background, but also suppresses significantly the pile-ups, thus enabling compensation of the lower efficiency of the plastic scintillators by performing measurements with higher positron source activities.

  17. Pulse shape discrimination using EJ-299-33 plastic scintillator coupled with a Silicon Photomultiplier array

    Science.gov (United States)

    Liao, Can; Yang, Haori

    2015-07-01

    Recent developments in organic plastic scintillators capable of pulse shape discrimination (PSD) have gained much interest. Novel photon detectors, such as Silicon Photomultipliers (SiPMs), offer numerous advantages and can be used as an alternative to conventional photo multiplier tubes (PMTs) in many applications. In this work, we evaluate the PSD performance of the EJ-299-33 plastic scintillator coupled with a SiPM array. 2D PSD plots as well as the Figure of Merit (FOM) parameters are presented to demonstrate the PSD capability of EJ-299-33 using a SiPM as the light sensor. The best FOM of 0.76 was observed with a 1.0 MeVee (MeV-electron-equivalent) energy threshold, despite the high noise level of the SiPM array. A high-speed digital oscilloscope was used to acquire data, which was then processed offline in MATLAB. A performance comparison between two different PSD algorithms was carried out. The dependence of PSD quality on the sampling rate was also evaluated, stimulated by the interest to implement this setup for handheld applications where power consumption is crucial.

  18. Properties of the Ukrainian Polystyrene-Based Plastic Scintillator UPS 923A

    CERN Document Server

    Artikov, A M; Chirikov-Zorin, I E; Chokheli, D; Lyablin, M; Bellettini, G; Menzione, A; Tokar, S; Giokaris, N; Manousakis-Katsikakis, A

    2005-01-01

    The polystyrene-based scintillator UPS 923A was chosen for upgrading of the muon system for the CDF detector at the Fermilab Tevatron. Properties of this scintillator such as light output, light attenuation, long-term stability and also timing characteristics of scintillator and wavelength shifting fibers were investigated. The method for the Bulk Attenuation Length measurements of the scintillator to its own light emitted was proposed. Comparative measurements of the characteristics of the UPS 923A and the polyvinyltoluene-based scintillator NE 114 were performed. It was found that natural aging of the NE 114 was two times faster than that of the UPS 923A.

  19. LHCb : A Scintillating Fibre Trackind Detector for the LHCb Upgrade

    CERN Multimedia

    Lindner, Rolf

    2014-01-01

    LHCb is preparing the upgrade which is scheduled to be installed in 2018/19. The Scintillating Fibre (SciFi) Tracker will be designed to replace the current tracking system downstream of the magnet, required to run at an increased luminosity of 1 - 2 10$^{33}$ cm$^{-2}$s$^{-1}$ and to collect a total of 50fb$^{-1}$ of data. The readout of the detector will be at 40MHz, applying a full software based trigger for every single bunch crossing. The SciFi Tracker consists of 12 planes covering a total surface of 350 m2. Modules are based on 2.5 m long multilayer ribbons made of 250 um diameter scintillating fibres as the active medium and signal transport. Silicon photomultiplier (SiPM) arrays with 128 channels at a width of 250 um are used for the readout. The signals from the SiPMS are digitized on an ASIC chip before reconstructing the track hit position within an FPGA on the front-end board. Several challenges facing this detector and the significant progress over the last year will be presented regarding the p...

  20. The impact of fluorescent dyes on the performances of polystyrene-based plastic scintillators

    Science.gov (United States)

    Zhu, Jun; Deng, Cheng; Jiang, Huimin; Zheng, Zhanlong; Gong, Rui; Bi, Yutie; Zhang, Lin; Lin, Runxiong

    2016-11-01

    To investigate the influence of both the first luminescent additive and the wavelength-shifter on the performance of plastic scintillator, a series of polystyrene-based scintillator had been prepared by thermal polymerization. Three first luminescent additives (PPO, p-TP and b-PBD) and four wavelength-shifters (POPOP, Bis-MSB, Me-MSB and DPA) were added to the scintillators respectively. The comparison results showed that PPO and POPOP were the most adequate fluorescent dyes for the polystyrene-based plastic scintillator. Moreover, with the increase of the concentration of PPO and POPOP, the fluorescence intensity and light yield were increased firstly and then decreased. The plastic scintillator containing 2% PPO and 0.02% POPOP had the highest fluorescence intensity and light yield.

  1. Simulation and optimisation of a position sensitive scintillation detector with wavelength shifting fibers for thermal neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Herzkamp, Matthias; Engels, Ralf; Kemmerling, Guenter [ZEA-2, Forschungszentrum Juelich (Germany); Brueckel, Thomas [JCNS, Forschungszentrum Juelich (Germany); Stahl, Achim [III. Physikalisches Institut B, RWTH Aachen (Germany); Waasen, Stefan van [ZEA-2, Forschungszentrum Juelich (Germany); Faculty of Engineering, University of Duisburg-Essen (Germany)

    2015-07-01

    In neutron scattering experiments it is important to have position sensitive large scale detectors for thermal neutrons. A detector based on a neutron scintillator with wave length shifting fibers is a new kind of such a detector. We present the simulation of the detector based on the microscopic structure of the scintillation material of the mentioned detector. It consists of a converter and a scintillation powder bound in a matrix. The converter in our case is lithium fluoride with enriched lithium 6, to convert thermal neutrons into high energetic alpha and triton particles. The scintillation material is silver doped zinc sulfide. We show that pulse height spectra obtained by these scintillators can be be explained by the simple model of randomly distributed spheres of zinc sulfide and lithium fluoride. With this model, it is possible to optimise the mass ratio of zinc sulfide to lithium fluoride with respect to detection efficiency and/or energy deposition in zinc sulfide.

  2. Long-distance transmission of light in a scintillator-based radiation detector

    Energy Technology Data Exchange (ETDEWEB)

    Dowell, Jonathan L.; Talbott, Dale V.; Hehlen, Markus P.

    2017-07-11

    Scintillator-based radiation detectors capable of transmitting light indicating the presence of radiation for long distances are disclosed herein. A radiation detector can include a scintillator layer and a light-guide layer. The scintillator layer is configured to produce light upon receiving incident radiation. The light-guide layer is configured to receive light produced by the scintillator layer and either propagate the received light through the radiation detector or absorb the received light and emit light, through fluorescence, that is propagated through the radiation detector. A radiation detector can also include an outer layer partially surrounding the scintillator layer and light-guide layer. The index of refraction of the light-guide layer can be greater than the index of refraction of adjacent layers.

  3. Development and Studies of Novel Microfabricated Radiation Hard Scintillation Detectors With High Spatial Resolution

    CERN Document Server

    Mapelli, A; Haguenauer, M; Jiguet, S; Renaud, P; Vico Triviño, N

    2011-01-01

    A new type of scintillation detector is being developed with standard microfabrication techniques. It consists of a dense array of scintillating waveguides obtained by coupling microfluidic channels filled with a liquid scintillator to photodetectors. Easy manipulation of liquid scintillators inside microfluidic devices allow their flushing, renewal, and exchange making the active medium intrinsically radiation hard. Prototype detectors have been fabricated by photostructuration of a radiation hard epoxy resin (SU-8) deposited on silicon wafers and coupled to a multi-anode photomultiplier tube (MAPMT) to read-out the scintillation light. They have been characterized by exciting the liquid scintillator in the 200 micrometers thick microchannels with electrons from a 90Sr yielding approximately 1 photoelectron per impinging Minimum Ionizing Particle (MIP). These promising results demonstrate the concept of microfluidic scintillating detection and are very encouraging for future developments.

  4. Compressive Sensing of Signals Generated in Plastic Scintillators in a Novel J-PET Instrument

    CERN Document Server

    Raczynski, L; Kowalski, P; Wislicki, W; Bednarski, T; Bialas, P; Czerwinski, E; Gajos, A; Kaplon, L; Kochanowski, A; Korcyl, G; Kowal, J; Kozik, T; Krzemien, W; Kubicz, E; Niedzwiecki, Sz; Palka, M; Rudy, Z; Rundel, O; Salabura, P; Sharma, N G; Silarski, M; lomski, A S; Smyrski, J; Strzelecki, A; Wieczorek, A; Zielinski, M; Zon, N

    2015-01-01

    The J-PET scanner, which allows for single bed imaging of the whole human body, is currently under development at the Jagiellonian University. The dis- cussed detector offers improvement of the Time of Flight (TOF) resolution due to the use of fast plastic scintillators and dedicated electronics allowing for sam- pling in the voltage domain of signals with durations of few nanoseconds. In this paper we show that recovery of the whole signal, based on only a few samples, is possible. In order to do that, we incorporate the training signals into the Tikhonov regularization framework and we perform the Principal Component Analysis decomposition, which is well known for its compaction properties. The method yields a simple closed form analytical solution that does not require iter- ative processing. Moreover, from the Bayes theory the properties of regularized solution, especially its covariance matrix, may be easily derived. This is the key to introduce and prove the formula for calculations of the signal recove...

  5. Utilization of wavelength-shifting fibers coupled to ZnS(Ag) and plastic scintillator for simultaneous detection of alpha/beta particles

    Energy Technology Data Exchange (ETDEWEB)

    Ifergan, Y., E-mail: Yairifergan@gmail.com [Electronics & Control Laboratories, Nuclear Research Center Negev, PO Box 9001, Beer Sheva (Israel); Dadon, S. [Electronics & Control Laboratories, Nuclear Research Center Negev, PO Box 9001, Beer Sheva (Israel); Israelashvili, I. [Physics Department, Nuclear Research Center of the Negev, PO Box 9001, Beer Sheva (Israel); Osovizky, A. [Radiation Detection Department, Rotem Industries Ltd, Beer Sheva (Israel); Gonen, E.; Yehuda-Zada, Y.; Smadja, D. [Electronics & Control Laboratories, Nuclear Research Center Negev, PO Box 9001, Beer Sheva (Israel); Knafo, Y.; Ginzburg, D. [Radiation Detection Department, Rotem Industries Ltd, Beer Sheva (Israel); Kadmon, Y.; Cohen, Y.; Mazor, T. [Electronics & Control Laboratories, Nuclear Research Center Negev, PO Box 9001, Beer Sheva (Israel)

    2015-06-01

    Low level radioactive surface contamination measurements require lightweight, large area and high efficiency detector. In most existing scintillation detectors there is a tradeoff between effective area and scintillation light collection. By using wavelength shifting (WLS) fibers the scintillation light may be collected efficiently also in a large area detector. In this study, WLS fibers were coupled to a beta sensitive plastic scintillator layer and to a alpha sensitive silver-activated zinc sulfide ZnS(Ag) layer for detecting both alpha and beta particles. The WLS fibers collect the scintillation light from the whole detector and transfer it to a single PMT. This first prototype unique configuration enables monitoring radioactive contaminated surfaces by both sides of the detector and provides high gamma rejection. In this paper, the detector structure, as well as the detector’s measured linear response, will be described. The measured detection efficiency of {sup 238}Pu alpha particles (5.5 MeV) is ~63%. The measured detection efficiency for beta particles is ~89% for {sup 90}Sr–{sup 90}Y (average energy of 195.8 keV, 934.8 keV), ~50% for {sup 36}Cl (average energy of 251.3 keV), and 35% for {sup 137}Cs (average energy of 156.8 keV)

  6. Study on calibration of neutron efficiency and relative photo-yield of plastic scintillator

    CERN Document Server

    Peng Tai Ping; Li Ru Rong; Zhang Jian Hua; Luo Xiao Bing; Xia Yi Jun; Yang Zhi Hu

    2002-01-01

    A method used for the calibration of neutron efficiency and the relative photo yield of plastic scintillator is studied. T(p, n) and D(d, n) reactions are used as neutron resources. The neutron efficiencies and the relative photo yields of plastic scintillators 1421 (40 mm in diameter and 5 mm in thickness) and determined in the neutron energy range of 0.655-5 MeV

  7. Surface coatings as xenon diffusion barriers on plastic scintillators : Improving Nuclear-Test-Ban Treaty verification

    OpenAIRE

    Bläckberg, Lisa

    2011-01-01

    This thesis investigates the ability of transparent surface coatings to reduce xenon diffusion into plastic scintillators. The motivation for the work is improved radioxenon monitoring equipment, used with in the framework of the verification regime of the Comprehensive Nuclear-Test-Ban Treaty. A large part of the equipment used in this context incorporates plastic scintillators which are in direct contact with the radioactive gas to be detected. One problem with such setup is that radioxenon...

  8. Advanced Scintillator Detectors for Neutron Imaging in Inertial Confinement Fusion

    Science.gov (United States)

    Geppert-Kleinrath, Verena; Danly, Christopher; Merrill, Frank; Simpson, Raspberry; Volegov, Petr; Wilde, Carl

    2016-10-01

    The neutron imaging team at Los Alamos National Laboratory (LANL) has been providing two-dimensional neutron imaging of the inertial confinement fusion process at the National Ignition Facility (NIF) for over five years. Neutron imaging is a powerful tool in which position-sensitive detectors register neutrons emitted in the fusion reactions, producing a picture of the burning fuel. Recent images have revealed possible multi-dimensional asymmetries, calling for additional views to facilitate three-dimensional imaging. These will be along shorter lines of sight to stay within the existing facility at NIF. In order to field imaging capabilities equivalent to the existing system several technological challenges have to be met: high spatial resolution, high light output, and fast scintillator response to capture lower-energy neutrons, which have scattered from non-burning regions of fuel. Deuterated scintillators are a promising candidate to achieve the timing and resolution required; a systematic study of deuterated and non-deuterated polystyrene and liquid samples is currently ongoing. A test stand has been implemented to measure the response function, and preliminary data on resolution and light output have been obtained at the LANL Weapons Neutrons Research facility.

  9. Discovery potential for supernova relic neutrinos with slow liquid scintillator detectors

    Science.gov (United States)

    Wei, Hanyu; Wang, Zhe; Chen, Shaomin

    2017-06-01

    Detection of supernova relic neutrinos could provide key support for our current understanding of stellar and cosmological evolution, and precise measurements of these neutrinos could yield novel insights into the universe. In this paper, we studied the detection potential of supernova relic neutrinos using linear alkyl benzene (LAB) as a slow liquid scintillator. The linear alkyl benzene features good separation of Cherenkov and scintillation lights, thereby providing a new route for particle identification. We further addressed key issues in current experiments, including (1) the charged current background of atmospheric neutrinos in water Cherenkov detectors and (2) the neutral current background of atmospheric neutrinos in typical liquid scintillator detectors. A kiloton-scale LAB detector at Jinping with O(10) years of data could discover supernova relic neutrinos with a sensitivity comparable to that of large-volume water Cherenkov detectors, typical liquid scintillator detectors, and liquid argon detectors.

  10. Influence of Depth of Interaction upon the Performance of Scintillator Detectors

    CERN Document Server

    Brown, Mark S.; Taylor, Alaric; Tummeltshammer, Clemens; Auffray, Etiennette; Lecoq, Paul; Papakonstantinou, Ioannis

    2014-01-01

    The uncertainty in time of particle detection within a scintillator detector, characterised by the coincidence time resolution (CTR), is explored with respect to the interaction position within the scintillator crystal itself. Electronic collimation between two scintillator detectors is utilised to determine the CTR with depth of interaction (DOI) for different materials, geometries and wrappings. Significantly, no relationship between the CTR and DOI is observed within experimental error. Confinement of the interaction position is seen to degrade the CTR in long scintillator crystals by 10%.

  11. Scintillating fibre detector for the Mu3e experiment

    Science.gov (United States)

    Bravar, S.; Corrodi, S.; Damyanova, A.; Grab, C.; Gredig, R.; Papa, A.; Rutar, G.

    2017-07-01

    Mu3e is a dedicated experiment to search for the rare lepton flavour violating decay μ+ → e+e-e+. Its ultimate goal is to find or exclude this process with a sensitivity of one in 1016 muon decays. This constitutes four orders of magnitude improvement with respect to the current state-of-the art. A thin multi-layer scintillating fibre detector consisting of 250μm fibres read out on both sides with silicon photomultiplier arrays provides an excellent time measurement with σ<500ps in order to reject combinatorial background at a muon stopping rate around 108 muon/s, concurrently minimizing the material budget to X/X0<0.3%. The design, performance and readout concept, including the dedicated readout chip MuTRiG, is presented.

  12. Developing Detectors for Scintillation Light in Liquid Argon for DUNE

    Energy Technology Data Exchange (ETDEWEB)

    Howard, Bruce [Fermilab

    2016-12-22

    The Deep Underground Neutrino experiment will conduct a broad program of physics research by studying a beam of neutrinos from Fermilab, atmospheric neutrinos, neutrinos from potential supernovae, and potential nucleon decay events. In pursuit of these studies, the experiment will deploy four 10kt fiducial mass liquid argon time projection chambers underground in Lead, South Dakota. Liquid argon time projection chambers allow high-resolution tracking and energy measurements. A precise timing signal is needed to provide the necessary time stamp to localize events in the drift direction. As liquid argon is a natural scintillator, a photon detection system will be deployed to provide such a signal, especially for non-beam events. In the baseline design for the single-phase time projection chamber, the detectors are contained within the anode plane assemblies. The design of two prototypes utilizing wavelength shifters and light guides are presented, and aspects of the research and development program are discussed.

  13. Organic liquid scintillation detector shape and volume impact on radiation portal monitors

    Energy Technology Data Exchange (ETDEWEB)

    Paff, Marc G.; Clarke, Shaun D.; Pozzi, Sara A.

    2016-07-21

    We have developed and tested a radiation portal monitor using organic liquid scintillation detectors. In order to optimize our system designs, neutron measurements were carried out with three organic liquid scintillation detectors of different shapes and sizes, along with a {sup 3}He radiation portal monitor (RPM) as a reference. The three liquids tested were a 7.62 cm diameter by 7.62 cm length cylindrical active volume organic liquid scintillation detector, a 12.7 cm diameter by 12.7 cm length cylindrical active volume organic liquid scintillation detector, and a 25 cm by 25 cm by 10 cm “paddle” shaped organic liquid scintillation detector. Background and Cf-252 neutron measurements were recorded to allow for a comparison of neutron intrinsic efficiencies as well as receiver operating characteristics (ROC) curves between detectors. The 12.7 cm diameter cylindrical active volume organic liquid scintillation detector exhibited the highest intrinsic neutron efficiency (54%) of all three liquid scintillators. An ROC curve analysis for a heavily moderated Cf-252 measurement showed that using the 12.7 cm diameter by 12.7 cm length cylindrical active volume Eljen EJ309 organic liquid scintillation detector would result in the fewest needed detector units in order to achieve a near 100% positive neutron alarm rate while maintaining a better than 1 in 10,000 false alarm rate on natural neutron background. A small number of organic liquid scintillation detectors could therefore be a valid alternative to {sup 3}He in some RPM applications.

  14. Monte Carlo calculations of efficiencies for photon interactions in plastic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Bonzi, E.V.; Mainardi, R.T. (Facultad de Matematica, Astronomia y Fisica, Univ. Nacional de Cordoba (Argentina))

    1992-12-01

    Energy absorption and total peak efficiencies for plastic scintillators have been calculated by means of the Monte Carlo method. These results are of interest for potential uses of plastic scintillators as dosimetric or spectrometric devices. The calculations were carried out for photon energies from 2 keV up to 1 MeV. We considered all of the physical effects involved in each range of energy, photoelectric, Compton and Rayleigh. As a consistency test the same code was used to calculate efficiencies for NaI scintillators. The agreement with results published previously by other authors, within calculated errors, is very satisfactory. (orig.).

  15. Three dimensional photograph of electron tracks through a plastic scintillator

    CERN Document Server

    Filipenko, Mykhaylo; Hufschmidt, Patrick; Anton, Gisela; Campbell, Michael; Gleixner, Thomas; Leuchs, Gerd; Tick, Timo; Vallerga, John; Wagenpfeil, Michael; Michel, Thilo

    2014-01-01

    The reconstruction of particle trajectories makes it possible to distinguish between different types of charged particles. In the era of particle colliders and high luminosities, this was one of the key aspects for the discovery of many new particles, lately the Higgs-boson. In high-energy physics, where trajectories are rather long. large size trackers muste be used to achieve sufficient position resolution. This is not the case in low-energy particle physics experiments, where particle trajectories are very short. With current position-sensitive detection technologies it is difficult to obtain sufficient position resolution for particle identification in large sensitive volumes since all these detectors are based on the read-out of the ionization signal. This limitation is due to the diffusion of the drifting electrons. In this paper we demonstrate a "proof-of-principle" experiment for a new method for the tracking of charged particles. It takes advantage of the scintillation signal which is not affected by...

  16. Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography

    CERN Document Server

    Raczynski, L; Kowalski, P; Wislicki, W; Bednarski, T; Bialas, P; Czerwinski, E; Kaplon, L; Kochanowski, A; Korcyl, G; Kowal, J; Kozik, T; Krzemien, W; Kubicz, E; Molenda, M; Moskal, I; Niedzwiecki, Sz; Palka, M; Pawlik-Niedzwiecka, M; Rudy, Z; Salabura, P; Sharma, N G; Silarski, M; Slomski, A; Smyrski, J; Strzelecki, A; Wieczorek, A; Zielinski, M; Zon, N

    2014-01-01

    Currently inorganic scintillator detectors are used in all commercial Time of Flight Positron Emission Tomograph (TOF-PET) devices. The J-PET collaboration investigates a possibility of construction of a PET scanner from plastic scintillators which would allow for single bed imaging of the whole human body. This paper describes a novel method of hit-position reconstruction based on sampled signals and an example of an application of the method for a single module with a 30 cm long plastic strip, read out on both ends by Hamamatsu R4998 photomultipliers. The sampling scheme to generate a vector with samples of a PET event waveform with respect to four user-defined amplitudes is introduced. The experimental setup provides irradiation of a chosen position in the plastic scintillator strip with an annihilation gamma quanta of energy 511~keV. The statistical test for a multivariate normal (MVN) distribution of measured vectors at a given position is developed, and it is shown that signals sampled at four threshold...

  17. Monte Carlo simulation of a very high resolution thermal neutron detector composed of glass scintillator microfibers

    CERN Document Server

    Yushou, Song; Zhang, Xiaodong; Hayward, Jason P

    2016-01-01

    In order to develop a high spatial resolution (micron level) thermal neutron detector, a detector assembly composed of cerium doped lithium glass microfibers, each with a diameter of 1\\,$\\mu$m, is proposed, where the neutron absorption location is reconstructed from the observed charged particle products that result from neutron absorption. To suppress the cross talk of the scintillation light, each scintillating fiber is surrounded by air-filled glass capillaries with the same diameter as the fiber. This pattern is repeated to form a bulk microfiber detector. On one end, the surface of the detector is painted with a thin optical reflector to increase the light collection efficiency at the other end. Then the scintillation light emitted by any neutron interaction is transmitted to one end, magnified, and recorded by an intensified CCD camera. A simulation based on the Geant4 toolkit was developed to model this detector. All the relevant physics processes including neutron interaction, scintillation, and optic...

  18. Study of the characteristics of SiPMs matrix as a photosensor for the scintillation detectors

    CERN Document Server

    Dzaparova, I M; Gavrilyuk, Yu M; Petkov, V B; Sergeev, A V; Volchenko, V I; Yakimenko, S P; Yanin, A F

    2015-01-01

    The matrices formed of silicon photomultipliers (SiPMs) are very promising photosensors for the scintillation detectors. The use of SiPM matrices with appropriate optical collector gives, in principle, a possibility to do a snapshot of glowing track of charged particle traversing a scintillator. The prototype of such scintillation detector is under development now in INR RAS. The preliminary results of characterization study of the matrix ArrayC-60035-64P-PCB (SensL company) for the prototype of such detector are presented.

  19. An analytic technique for the estimation of the light yield of a scintillation detector

    CERN Document Server

    Segreto, Ettore

    2011-01-01

    A simple model for the estimation of the light yield of a scintillation detector starting from the knowledge of its optical parameters and under general assumptions is developed. It is also shown how to take into account the effects related to Rayleigh scattering and absorption of the photons. The predictions of the model are benchmarked with the outcomes of a Monte Carlo simulation of a specific scintillation detector. The case of a real scintillation detector with internal surface covered by wavelength-shifter is explicitly treated and the model prediction is compared with the measured light yield.

  20. Reconstruction of scintillations coordinates in cylindrical large detector with radial arrangement of photomultipliers

    CERN Document Server

    Alekseev, V M; Verbitskij, V S; Verbitskij, S S; Lapik, M A; Tselebrovskij, A N; Lapik, A M; Rusakov, A V; Savopulo, M L; Smirnov, V V; Chubarov, M N

    2002-01-01

    Paper describes algorithm to calculate scintillation coordinates elaborated for a coordinate-sensitive large detector based on liquid scintillator with radial arrangement of nine FEU-174 photomultipliers. Paper contains the simulation results of coordinate resolution dependence in detector centre on energy of gamma-quanta within 0.2-8 MeV range. Using this algorithm one processed the experimental data obtained with application of sup 6 sup 0 Co gamma-radiation source and the results of determination of scintillation coordinates for gamma-quanta beam. The accuracy of coordinate determination in detector centre when applying the descried algorithm constitutes approx 10 mm

  1. Development of a scintillation detector with a photosensor based on matrices of silicon photomultipliers

    Science.gov (United States)

    Yanin, A. F.; Dzaparova, I. M.; Gorbacheva, E. A.; Kurenya, A. N.; Kochkarov, M. M.; Petkov, V. B.; Sergeev, A. V.

    2017-01-01

    Scintillation detector with matrices of silicon photomultipliers (SiPM) as multi-channel photosensors is under development. The use of SiPM matrices gives a possibility to do a snapshot of glowing track of charged particle traversing a scintillator. The snapshots of the events inside the scintillator were taken for the two SiPM matrices arrangements. The comparison characteristics of snapshots for these arrangements are presented.

  2. Performance of Large Neutron Detectors Containing Lithium-Gadolinium-Borate Scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Slaughter, David M.; Stuart, Cory R.; Klaass, R. Fred; Merrill, David B. [MSI/Photogenics Division, Orem, Utah (United States)

    2015-07-01

    This paper describes the development and testing of a neutron counter, spectrometer, and dosimeter that is compact, efficient, and accurate. A self-contained neutron detection instrument has wide applications in health physics, scientific research, and programs to detect, monitor, and control strategic nuclear materials (SNM). The 1.3 liter detector head for this instrument is a composite detector with an organic scintillator containing uniformly distributed {sup 6}Li{sub 6}{sup nat}Gd{sup 10}B{sub 3}O{sub 9}:Ce (LGB:Ce) microcrystals. The plastic scintillator acts to slow impinging neutrons and emits light proportional to the energy lost by the neutrons as they moderate in the detector body. Moderating neutrons that have slowed sufficiently capture in one of the Lithium-6, Boron-10, or Gadolinium-157 atoms in the LGB:Ce scintillator, which then releases the capture energy in a characteristic cerium emission pulse. The measured captured pulses indicate the presence of neutrons. When a scintillating fluor is present in the plastic, the light pulse resulting from the neutron moderating in the plastic is paired with the LGB:Ce capture pulse to identify the energy of the neutron. About 2% of the impinging neutrons lose all of their energy in a single collision with the detector. There is a linear relationship between the pulse areas of this group of neutrons and energy. The other 98% of neutrons have a wide range of collision histories within the detector body. When these neutrons are 'binned' into energy groups, each group contains a distribution of pulse areas. This data was used to assist in the unfolding of the neutron spectra. The unfolded spectra were then validated with known spectra, at both neutron emitting isotopes and fission/accelerator facilities. Having validated spectra, the dose equivalent and dose rate are determined by applying standard, regulatory damage coefficients to the measured neutron counts for each energy bin of the spectra. Testing

  3. Memory effect, resolution, and efficiency measurements of an Al{sub 2}O{sub 3} coated plastic scintillator used for radioxenon detection

    Energy Technology Data Exchange (ETDEWEB)

    Bläckberg, L., E-mail: lisa.blackberg@physics.uu.se [Department of Physics and Astronomy, Uppsala University, Box 516, SE-75120 Uppsala (Sweden); Fritioff, T.; Mårtensson, L.; Nielsen, F.; Ringbom, A. [Division of Defence and Security Systems, Swedish Defence Research Agency (FOI), SE-17290 Stockholm (Sweden); Sjöstrand, H.; Klintenberg, M. [Department of Physics and Astronomy, Uppsala University, Box 516, SE-75120 Uppsala (Sweden)

    2013-06-21

    A cylindrical plastic scintillator cell, used for radioxenon monitoring within the verification regime of the Comprehensive Nuclear-Test-Ban Treaty, has been coated with 425 nm Al{sub 2}O{sub 3} using low temperature Atomic Layer Deposition, and its performance has been evaluated. The motivation is to reduce the memory effect caused by radioxenon diffusing into the plastic scintillator material during measurements, resulting in an elevated detection limit. Measurements with the coated detector show both energy resolution and efficiency comparable to uncoated detectors, and a memory effect reduction of a factor of 1000. Provided that the quality of the detector is maintained for a longer period of time, Al{sub 2}O{sub 3} coatings are believed to be a viable solution to the memory effect problem in question.

  4. Testing a new NIF neutron time-of-flight detector with a bibenzyl scintillator on OMEGA.

    Science.gov (United States)

    Glebov, V Yu; Forrest, C; Knauer, J P; Pruyne, A; Romanofsky, M; Sangster, T C; Shoup, M J; Stoeckl, C; Caggiano, J A; Carman, M L; Clancy, T J; Hatarik, R; McNaney, J; Zaitseva, N P

    2012-10-01

    A new neutron time-of-flight (nTOF) detector with a bibenzyl crystal as a scintillator has been designed and manufactured for the National Ignition Facility (NIF). This detector will replace a nTOF20-Spec detector with an oxygenated xylene scintillator currently operational on the NIF to improve the areal-density measurements. In addition to areal density, the bibenzyl detector will measure the D-D and D-T neutron yield and the ion temperature of indirect- and direct-drive-implosion experiments. The design of the bibenzyl detector and results of tests on the OMEGA Laser System are presented.

  5. Testing a new NIF neutron time-of-flight detector with a bibenzyl scintillator on OMEGA

    Energy Technology Data Exchange (ETDEWEB)

    Glebov, V. Yu.; Forrest, C.; Knauer, J. P.; Pruyne, A.; Romanofsky, M.; Sangster, T. C.; Shoup, M. J. III; Stoeckl, C. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623-1299 (United States); Caggiano, J. A.; Carman, M. L.; Clancy, T. J.; Hatarik, R.; McNaney, J.; Zaitseva, N. P. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2012-10-15

    A new neutron time-of-flight (nTOF) detector with a bibenzyl crystal as a scintillator has been designed and manufactured for the National Ignition Facility (NIF). This detector will replace a nTOF20-Spec detector with an oxygenated xylene scintillator currently operational on the NIF to improve the areal-density measurements. In addition to areal density, the bibenzyl detector will measure the D-D and D-T neutron yield and the ion temperature of indirect- and direct-drive-implosion experiments. The design of the bibenzyl detector and results of tests on the OMEGA Laser System are presented.

  6. Light yield measurements in a liquid scintillator detector with wavelength-shifting fibre readout

    CERN Document Server

    Doucet, M; Grégoire, G; Panman, J; Zucchelli, P

    2001-01-01

    A technique based on liquid scintillator with wavelength-shiftingfibre readout is interesting for large-mass neutrino detectors. In this paper, we present results obtained with a laboratoryprototype assembled at CERN. Mixtures made of economical chemicalcomponents were compared to commercial liquid scintillators. Thelight yield was also studied as a function of fibre diameter, fibreposition, and surface quality of the container.

  7. Dose rate effects in the radiation damage of the plastic scintillators of the CMS Hadron Endcap Calorimeter

    CERN Document Server

    Khachatryan, V.

    2016-01-01

    We present measurements of the reduction of light output by plastic scintillators irradiated in the CMS detector during the 8 TeV run of the Large Hadron Collider and show that they indicate a strong dose rate effect. The damage for a given dose is larger for lower dose rate exposures. The results agree with previous measurements of dose rate effects, but are stronger due to the very low dose rates probed. We show that the scaling with dose rate is consistent with that expected from diffusion effects.

  8. DETEC, a Subprogram for Simulation of the Fast-Neutron Detection Process in a Hydro-Carbonous Plastic Scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Gustafsson, B.; Aspelund, O.

    1966-07-15

    A description is given of the subprogram DETEC, which for energies below 5 MeV simulates the detection process of a fast-neutron within a large cylindrical plastic scintillator. DETEC has been coded in FORTRAN IV, and consists of a subroutine and a BLOCK-DATA subprogram. The latter is in its present form adapted to the dimensions 5 cm diam. x 8 cm of the scintillating materials NE102 and NE102A. The character of DETEC as a subprogram is manifest through the requirement of a main routine for generation of the following input parameters: 1. fast-neutron position; 2. direction; 3. energy; 4. entrance time; 5. input weight (all referred to the detector surface), and 6. the discriminator threshold. When these are provided, the virtues of DETEC are recording of the detected weight and the time elapsed prior to the detection event. The merits of DETEC are finally demonstrated in two typical applications.

  9. Neutron/gamma discrimination properties of composite scintillation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Iwanowska, J; Swiderski, L; Moszynski, M; Szczesniak, T; Sibczynski, P [The Soltan Institute for Nuclear Studies, Otwock-Swierk, PL-05-400 Poland (Poland); Galunov, N Z; Karavaeva, N L, E-mail: j.iwanowska@ipj.gov.pl [The Institute for Scintillation Materials of National Academy of Sciences of Ukraine, 60 Lenin Ave., 61001, Kharkov (Ukraine)

    2011-07-15

    A composite scintillator is a solid solution, which contains the grains of organic molecular single crystal introduced into a polymer matrix and placed inside the housing. Hereunder, we present n/{gamma} discrimination properties of four composite scintillators; two of the them are based on p-terphenyl and two others-on stilbene. The results obtained with a stilbene single crystal and a liquid scintillator BC501A are shown as a comparison. Initial conclusion, which is drawn from the paper, is that composite scintillators could be an alternative substitution for commonly used liquid scintillators.

  10. Detection of Extensive Cosmic Air Showers by Small Scintillation Detectors with Wavelength-Shifting Fibres

    Science.gov (United States)

    Aiola, Salvatore; La Rocca, Paola; Riggi, Francesco; Riggi, Simone

    2012-01-01

    A set of three small scintillation detectors was employed to measure correlated events due to the passage of cosmic muons originating from extensive air showers. The coincidence rate between (any) two detectors was extracted as a function of their relative distance. The difference between the arrival times in three non-aligned detectors was used…

  11. Scintillation Detector for the Measurement of Ultra-Heavy Cosmic Rays on the Super-TIGER Experiment

    Science.gov (United States)

    Link, Jason

    2011-01-01

    We discuss the design and construction of the scintillation detectors for the Super-TIGER experiment. Super-TIGER is a large-area (5.4sq m) balloon-borne experiment designed to measure the abundances of cosmic-ray nuclei between Z= 10 and Z=56. It is based on the successful TIGER experiment that flew in Antarctica in 2001 and 2003. Super-TIGER has three layers of scintillation detectors, two Cherenkov detectors and a scintillating fiber hodoscope. The scintillation detector employs four wavelength shifter bars surrounding the edges of the scintillator to collect the light from particles traversing the detector. PMTs are optically coupled at both ends of the bars for light collection. We report on laboratory performance of the scintillation counters using muons. In addition we discuss the design challenges and detector response over this broad charge range including the effect of scintilator saturation.

  12. Air core detectors for Cerenkov-free scintillation dosimetry of brachytherapy β-sources.

    Science.gov (United States)

    Eichmann, Marion; Thomann, Benedikt

    2017-09-01

    Plastic scintillation detectors are used for dosimetry in small radiation fields with high dose gradients, e.g., provided by β-emitting sources like (106) Ru/(106) Rh eye plaques. A drawback is a background signal caused by Cerenkov radiation generated by electrons passing the optical fibers (light guides) of this dosimetry system. Common approaches to correct for the Cerenkov signal are influenced by uncertainties resulting from detector positioning and calibration procedures. A different approach to avoid any correction procedure is to suppress the Cerenkov signal by replacing the solid core optical fiber with an air core light guide, previously shown for external beam therapy. In this study, the air core concept is modified and applied to the requirements of dosimetry in brachytherapy, proving its usability for measuring water energy doses in small radiation fields. Three air core detectors with different air core lengths are constructed and their performance in dosimetry for brachytherapy β-sources is compared with a standard two-fiber system, which uses a second fiber for Cerenkov correction. The detector systems are calibrated with a (90) Sr/(90) Y secondary standard and tested for their angular dependence as well as their performance in depth dose measurements of (106) Ru/(106) Rh sources. The signal loss relative to the standard detector increases with increasing air core length to a maximum value of 58.3%. At the same time, however, the percentage amount of Cerenkov light in the total signal is reduced from at least 12.1% to a value below 1.1%. There is a linear correlation between induced dose and measured signal current. The air core detectors determine the dose rates for (106) Ru/(106) Rh sources without any form of correction for the Cerenkov signal. The air core detectors show advantages over the standard two-fiber system especially when measuring in radiation fields with high dose gradients. They can be used as simple one-fiber systems and allow

  13. Monte Carlo simulation of the standardization of {sup 22}Na using scintillation detector arrays

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Y., E-mail: yss.sato@aist.go.j [National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Quantum Radiation Division, Radioactivity and Neutron Section, Tsukuba Central 2, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan); Murayama, H. [National Institute of Radiological Sciences, 4-9-1, Anagawa, Inage, Chiba 263-8555 (Japan); Yamada, T. [Japan Radioisotope Association, 2-28-45, Hon-komagome, Bunkyo, Tokyo 113-8941 (Japan); National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Quantum Radiation Division, Radioactivity and Neutron Section, Tsukuba Central 2, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan); Tohoku University, 6-6, Aoba, Aramaki, Aoba, Sendai 980-8579 (Japan); Hasegawa, T. [Kitasato University, 1-15-1, Kitasato, Sagamihara, Kanagawa 228-8555 (Japan); Oda, K. [Tokyo Metropolitan Institute of Gerontology, 1-1 Nakacho, Itabashi-ku, Tokyo 173-0022 (Japan); Unno, Y.; Yunoki, A. [National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Quantum Radiation Division, Radioactivity and Neutron Section, Tsukuba Central 2, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan)

    2010-07-15

    In order to calibrate PET devices by a sealed point source, we contrived an absolute activity measurement method for the sealed point source using scintillation detector arrays. This new method was verified by EGS5 Monte Carlo simulation.

  14. First performance test of newly developed plastic scintillator for radiation detection

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, M., E-mail: minori@hep.sc.niigata-u.ac.jp [Graduate School of Science and Technology, Niigata University, Niigata 950-2181 (Japan); Katsumata, M. [Faculty of Science, Physics Department, Niigata University, Niigata 950-2181 (Japan); Ono, H. [Nippon Dental University, School of Life Dentistry at Niigata, Niigata 951-8580 (Japan); Suzuki, T. [Graduate School of Science and Technology, Niigata University, Niigata 950-2181 (Japan); Miyata, H. [Faculty of Science, Physics Department, Niigata University, Niigata 950-2181 (Japan); Itoh, Y.; Ishida, K. [Graduate School of Science and Technology, Niigata University, Niigata 950-2181 (Japan); Tamura, M.; Yamaguchi, Y. [Carlit Holdings Co., Ltd., Chiyoda, Tokyo 101-0024 (Japan)

    2015-01-11

    We present a plastic scintillator, developed in collaboration with Carlit Holdings Co., Ltd., that is fabricated using a liquid parent material cured at room temperature by adding a hardener. The new scintillator can incorporate heat-labile functional materials such as gadolinium to enhance neutron sensitivity. The characteristics of the new scintillator, in particular the light yield and attenuation length, were evaluated using a {sup 90}Sr β-ray source. The light yield was measured 7% Anthracene on the basis of a comparison with commercially available scintillator (BC-408) at a distance of 18 cm from the photodetector surface. This light yield is dependent on the distance between the luminous point and the photodetector because of light attenuation. The attenuation length of the Gd-doped scintillator was about 50 cm.

  15. Segmented scintillation detectors with silicon photomultiplier readout for measuring antiproton annihilations.

    Science.gov (United States)

    Sótér, A; Todoroki, K; Kobayashi, T; Barna, D; Horváth, D; Hori, M

    2014-02-01

    The Atomic Spectroscopy and Collisions Using Slow Antiprotons experiment at the Antiproton Decelerator (AD) facility of CERN constructed segmented scintillators to detect and track the charged pions which emerge from antiproton annihilations in a future superconducting radiofrequency Paul trap for antiprotons. A system of 541 cast and extruded scintillator bars were arranged in 11 detector modules which provided a spatial resolution of 17 mm. Green wavelength-shifting fibers were embedded in the scintillators, and read out by silicon photomultipliers which had a sensitive area of 1 × 1 mm(2). The photoelectron yields of various scintillator configurations were measured using a negative pion beam of momentum p ≈ 1 GeV/c. Various fibers and silicon photomultipliers, fiber end terminations, and couplings between the fibers and scintillators were compared. The detectors were also tested using the antiproton beam of the AD. Nonlinear effects due to the saturation of the silicon photomultiplier were seen at high annihilation rates of the antiprotons.

  16. A new timing model for calculating the intrinsic timing resolution of a scintillator detector.

    Science.gov (United States)

    Shao, Yiping

    2007-02-21

    The coincidence timing resolution is a critical parameter which to a large extent determines the system performance of positron emission tomography (PET). This is particularly true for time-of-flight (TOF) PET that requires an excellent coincidence timing resolution (scintillator detector: scintillation decay time and total photoelectron yield from the photon-electron conversion. However, this calculation has led to significant errors when the coincidence timing resolution reaches 1 ns or less. In this paper, a bi-exponential timing model is derived and evaluated. The new timing model includes an additional parameter of a scintillator detector: scintillation rise time. The effect of rise time on the timing resolution has been investigated analytically, and the results reveal that the rise time can significantly change the timing resolution of fast scintillators that have short decay time constants. Compared with measured data, the calculations have shown that the new timing model significantly improves the accuracy in the calculation of timing resolutions.

  17. Impact of geometry on light collection efficiency of scintillation detectors for cryogenic rare event searches

    Energy Technology Data Exchange (ETDEWEB)

    Danevich, F.A.; Kobychev, V.V. [Institute for Nuclear Research, MSP 03680 Kyiv (Ukraine); Kobychev, R.V. [Institute for Nuclear Research, MSP 03680 Kyiv (Ukraine); National Technical University of Ukraine “Kyiv Polytechnic Institute”, 03056 Kyiv (Ukraine); Kraus, H. [Department of Physics, University of Oxford, Oxford OX1 3RH (United Kingdom); Mikhailik, V.B., E-mail: vmikhai@hotmail.com [Department of Physics, University of Oxford, Oxford OX1 3RH (United Kingdom); Diamond Light Source, Didcot OX11 0DE (United Kingdom); Mokina, V.M. [Institute for Nuclear Research, MSP 03680 Kyiv (Ukraine); Solsky, I.M. [Scientific Research Company CARAT, 79031 Lviv (Ukraine)

    2014-10-01

    Simulations of photon propagation in scintillation detectors were performed with the aim to find the optimal scintillator geometry, surface treatment, and shape of external reflector in order to achieve maximum light collection efficiency for detector configurations that avoid direct optical coupling, a situation that is commonly found in cryogenic scintillating bolometers in experimental searches for double beta decay and dark matter. To evaluate the light collection efficiency of various geometrical configurations we used the ZEMAX ray-tracing software. It was found that scintillators in the shape of a triangular prism with an external mirror shaped as truncated cone gives the highest light collection efficiency. The results of the simulations were confirmed by carrying out measurements of the light collection efficiencies of CaWO{sub 4} crystal scintillators. A comparison of simulated and measured values of light output shows good agreement.

  18. Segmented scintillation detectors with silicon photomultiplier readout for measuring antiproton annihilations

    CERN Document Server

    Sótér, A; Kobayashi, T; Barna, D; Horvath, D; Hori, M

    2014-01-01

    The Atomic Spectroscopy and Collisions Using Slow Antiprotons (ASACUSA) experiment at the Antiproton Decelerator (AD) facility of CERN constructed segmented scintillators to detect and track the charged pions which emerge from antiproton annihilations in a future superconducting radiofrequency Paul trap for antiprotons. A system of 541 cast and extruded scintillator bars were arranged in 11 detector modules which provided a spatial resolution of 17 mm. Green wavelength-shifting fibers were embedded in the scintillators, and read out by silicon photomultipliers which had a sensitive area of 1 x 1 mm^2. The photoelectron yields of various scintillator configurations were measured using a negative pion beam of momentum p ~ 1 GeV/c. Various fibers and silicon photomultipliers, fiber end terminations, and couplings between the fibers and scintillators were compared. The detectors were also tested using the antiproton beam of the AD. Nonlinear effects due to the saturation of the silicon photomultiplier were seen a...

  19. Discrimination methods between neutron and gamma rays for boron loaded plastic scintillators

    CERN Document Server

    Normand, S; Haan, S; Louvel, M

    2002-01-01

    Boron loaded plastic scintillators exhibit interesting properties for neutron detection in nuclear waste management and especially in investigating the amount of fissile materials when enclosed in waste containers. Combining a high thermal neutron efficiency and a low mean neutron lifetime, they are suitable in neutron multiplicity counting. However, due to their high sensitivity to gamma rays, pulse shape discrimination methods need to be developed in order to optimize the passive neutron assay measurement. From the knowledge of their physical properties, it is possible to separate the three kinds of particles that have interacted in the boron loaded plastic scintillator (gamma, fast neutron and thermal neutron). For this purpose, we have developed and compared the two well known discrimination methods (zero crossing and charge comparison) applied for the first time to boron loaded plastic scintillator. The setup for the zero crossing discrimination method and the charge comparison methods is thoroughly expl...

  20. Performance of liquid argon neutrino detectors with enhanced sensitivity to scintillation light

    CERN Document Server

    Sorel, M

    2014-01-01

    Scintillation light is used in liquid argon neutrino detectors to provide a trigger signal, veto information against cosmic rays, and absolute event timing. In this work, we discuss additional opportunities offered by detectors with enhanced sensitivity to scintillation light, that is with light collection efficiencies of about $10^{-3}$. We focus on two key detector performance indicators for neutrino oscillation physics: calorimetric neutrino energy reconstruction and neutrino/antineutrino separation in a non-magnetized detector. Our simulations indicate that a neutrino energy resolution as good as 3.3\\% RMS for 4 GeV electron neutrino charged-current interactions can in principle be obtained in a large detector of this type, by using both charge and light information. By exploiting muon capture in argon and scintillation light information to veto muon decay electrons, we also obtain muon neutrino identification efficiencies of about 50\\%, and muon antineutrino misidentification rates at the few percent lev...

  1. Rejection of Alpha Surface Background in Non-scintillating Bolometric Detectors: The ABSuRD Project

    Science.gov (United States)

    Biassoni, M.; Brofferio, C.; Bucci, C.; Canonica, L.; di Vacri, M. L.; Gorla, P.; Pavan, M.; Yeh, M.

    2016-08-01

    Due to their excellent energy resolution values and the vast choice of possible materials, bolometric detectors are currently widely used in the physics of rare events. A limiting aspect for bolometers rises from their inability to discriminate among radiation types or surface from bulk events. It has been demonstrated that the main limitation to sensitivity for purely bolometric detectors is represented by surface alpha contaminations, causing a continuous background that cannot be discriminated. A new scintillation-based technique for the rejection of surface alpha background in non-scintillating bolometric experiments is proposed in this work. The idea is to combine a scintillating and a high sensitivity photon detector with a non-scintillating absorber. We present results showing the possibility to reject events due to alpha decay at or nearby the surface of the crystal.

  2. How to observe 8B solar neutrinos in liquid scintillator detectors

    CERN Document Server

    Ianni, A; Villante, F L

    2016-01-01

    We show that liquid organic scintillator detectors (e.g., KamLAND and Borexino) can measure the 8B solar neutrino flux by means of the nu_e charged current interaction with the 13C nuclei naturally contained in the scintillators. The neutrino events can be identified by exploiting the time and space coincidence with the subsequent decay of the produced 13N nuclei. We perform a detailed analysis of the background in KamLAND, Borexino and in a possible liquid scintillator detector at SNOLab, showing that the 8B solar neutrino signal can be extracted with a reasonable uncertainty in a few years of data taking. KamLAND should be able to extract about 18 solar neutrino events from the already collected data. Prospects for gigantic scintillator detectors (such as LENA) are also studied.

  3. Optimizing timing performance of silicon photomultiplier-based scintillation detectors.

    Science.gov (United States)

    Yeom, Jung Yeol; Vinke, Ruud; Levin, Craig S

    2013-02-21

    Precise timing resolution is crucial for applications requiring photon time-of-flight (ToF) information such as ToF positron emission tomography (PET). Silicon photomultipliers (SiPM) for PET, with their high output capacitance, are known to require custom preamplifiers to optimize timing performance. In this paper, we describe simple alternative front-end electronics based on a commercial low-noise RF preamplifier and methods that have been implemented to achieve excellent timing resolution. Two radiation detectors with L(Y)SO scintillators coupled to Hamamatsu SiPMs (MPPC S10362-33-050C) and front-end electronics based on an RF amplifier (MAR-3SM+), typically used for wireless applications that require minimal additional circuitry, have been fabricated. These detectors were used to detect annihilation photons from a Ge-68 source and the output signals were subsequently digitized by a high speed oscilloscope for offline processing. A coincident resolving time (CRT) of 147 ± 3 ps FWHM and 186 ± 3 ps FWHM with 3 × 3 × 5 mm(3) and with 3 × 3 × 20 mm(3) LYSO crystal elements were measured, respectively. With smaller 2 × 2 × 3 mm(3) LSO crystals, a CRT of 125 ± 2 ps FWHM was achieved with slight improvement to 121 ± 3 ps at a lower temperature (15° C). Finally, with the 20 mm length crystals, a degradation of timing resolution was observed for annihilation photon interactions that occur close to the photosensor compared to shallow depth-of-interaction (DOI). We conclude that commercial RF amplifiers optimized for noise, besides their ease of use, can produce excellent timing resolution comparable to best reported values acquired with custom readout electronics. On the other hand, as timing performance degrades with increasing photon DOI, a head-on detector configuration will produce better CRT than a side-irradiated setup for longer crystals.

  4. Semiconductor scintillator detector for gamma radiation; Detector cintilador semicondutor para radiacao gama

    Energy Technology Data Exchange (ETDEWEB)

    Laan, F.T.V. der; Borges, V.; Zabadal, J.R.S., E-mail: ftvdl@ufrgs.br, E-mail: borges@ufrgs.br, E-mail: jorge.zabadal@ufrgs.br [Universidade Federal do Rio Grande do Sul (GENUC/DEMEC/UFRGS), Porto Alegre, RS (Brazil). Grupo de Estudos Nucleares. Departamento de Engenharia Mecanica

    2015-07-01

    Nowadays the devices employed to evaluate individual radiation exposition are based on dosimetric films and thermoluminescent crystals, whose measurements must be processed in specific transductors. Hence, these devices carry out indirect measurements. Although a new generation of detectors based on semiconductors which are employed in EPD's (Electronic Personal Dosemeters) being yet available, it high producing costs and large dimensions prevents the application in personal dosimetry. Recent research works reports the development of new detection devices based on photovoltaic PIN diodes, which were successfully employed for detecting and monitoring exposition to X rays. In this work, we step forward by coupling a 2mm anthracene scintillator NE1, which converts the high energy radiation in visible light, generating a Strong signal which allows dispensing the use of photomultipliers. A low gain high performance amplifier and a digital acquisition device are employed to measure instantaneous and cumulative doses for energies ranging from X rays to Gamma radiation up to 2 MeV. One of the most important features of the PIN diode relies in the fact that it can be employed as a detector for ionization radiation, since it requires a small energy amount for releasing electrons. Since the photodiode does not amplify the corresponding photon current, it must be coupled to a low gain amplifier. Therefore, the new sensor works as a scintillator coupled with a photodiode PIN. Preliminary experiments are being performed with this sensor, showing good results for a wide range of energy spectrum. (author)

  5. Performance of a scintillating strip detector with G-APD readout

    Energy Technology Data Exchange (ETDEWEB)

    Tarkovsky, Evgueny, E-mail: tarkovsk@itep.r [Institute for Theoretical and Experimental Physics, B. Cheremushkinskaya, 25, Moscow 117218 (Russian Federation)

    2011-02-01

    The upgraded KLM detector end cap of Belle II experiment will consist of more than 16 000 scintillating detectors of 0.5-2.8 m long strips. One of possible solutions is presented: a detector of 2800x40x10 mm{sup 3} with light readout via WLS fiber and new solid state photo-detector multi-pixel avalanche photo-diode working in Geiger mode. Concept of the mechanical structure of upgraded KLM detector is given. Properties demonstrating the operation capabilities of such a scintillating detector: MIP registration efficiency, noise pulse rate with respect to expected background rate are demonstrated as well as response distributions in longitudinal and transverse directions. Study of radiation damage of photo-detectors shows that Hamamatsu MPPC can be used in Belle II environment during at least 10 years.

  6. Characterization of detector scintillator effect on interventional device visualization in x-ray fluoroscopy

    Science.gov (United States)

    Jiang, Yuhao; Wilson, David L.

    2005-04-01

    Flat panel detectors have a large number of parameters that affect fluoroscopy image quality. Scintillator thickness is very important and can be changed in fabrication. In general, with increasing thickness, there is a degradation of MTF with spatial blurring but improved conversion efficiency. This design trade-off should be optimized for visualization. Using quantitative experimental and techniques, we simulated three detector models, including a direct detector and two indirect detectors with different scintillator thickness (160 and 210 mg/cm2) and displayed each "acquired" pixel directly on the screen without further processing in a sequence of fluoroscopy images. To measure image quality, we investigated detection of two interventional devices: stents and guide wires. Human observers and a channelized human observer model both demonstrated that detection depended on detector scintillator thickness and the type of interventional device. Detection performance was improved with the thicker scintillator, especially at low exposure. A simulated direct detector gave less blurring and even better detection performance for stent detection. The thick indirect detector gave contrast sensitivities equal to those for the direct detector for the case of guide wire detection. An ideal observer model gave trends similar to those for human observers, even though it does not account for many features of human viewing of image sequences and gives extraordinarily high detection SNR values because it uses all images in a sequence.

  7. Improved Nearest Neighbor Methods for Gamma Photon Interaction Position Determination in Monolithic Scintillator PET Detectors

    NARCIS (Netherlands)

    van Dam, Herman T.; Seifert, Stefan; Vinke, Ruud; Dendooven, Peter; Lohner, Herbert; Beekman, Freek J.; Schaart, Dennis R.

    2011-01-01

    Monolithic scintillator detectors have been shown to provide good performance and to have various practical advantages for use in PET systems. Excellent results for the gamma photon interaction position determination in these detectors have been obtained by means of the k-nearest neighbor (k-NN)

  8. Scintillating fiber detectors for the HypHI project at GSI

    NARCIS (Netherlands)

    Nakajima, D.; Oezel-Tashenov, B.; Bianchin, S.; Borodina, O.; Bozkurt, V.; Gokuzum, B.; Kavatsyuk, M.; Minami, S.; Rappold, C.; Saito, T. R.; Achenbach, P.; Ajimura, S.; Ayerbe, C.; Fukuda, T.; Hayashi, Y.; Hiraiwa, T.; Hoffmann, J.; Koch, K.; Kurz, N.; Lepyoshkina, O.; Maas, F.; Mizoi, Y.; Mochizuki, T.; Moritsu, M.; Nagae, T.; Nungesser, L.; Okamura, A.; Ott, W.; Pochodzalla, J.; Sakaguchi, A.; Sako, M.; Schmidt, C. J.; Sugimura, H.; Tanida, K.; Traeger, M.; Trautmann, W.; Voltz, S.

    2009-01-01

    The construction and properties of three sets of two-dimensional scintillating fiber detector arrays for tracking of charged particles used in the HypHI Phase 0 experiment at GSI will be reported in this paper. The position resolutions and the detection efficiency of detectors have been obtained for

  9. Scintillating fiber detectors for the HypHI project at GSI

    NARCIS (Netherlands)

    Nakajima, D.; Oezel-Tashenov, B.; Bianchin, S.; Borodina, O.; Bozkurt, V.; Gokuzum, B.; Kavatsyuk, M.; Minami, S.; Rappold, C.; Saito, T. R.; Achenbach, P.; Ajimura, S.; Ayerbe, C.; Fukuda, T.; Hayashi, Y.; Hiraiwa, T.; Hoffmann, J.; Koch, K.; Kurz, N.; Lepyoshkina, O.; Maas, F.; Mizoi, Y.; Mochizuki, T.; Moritsu, M.; Nagae, T.; Nungesser, L.; Okamura, A.; Ott, W.; Pochodzalla, J.; Sakaguchi, A.; Sako, M.; Schmidt, C. J.; Sugimura, H.; Tanida, K.; Traeger, M.; Trautmann, W.; Voltz, S.

    2009-01-01

    The construction and properties of three sets of two-dimensional scintillating fiber detector arrays for tracking of charged particles used in the HypHI Phase 0 experiment at GSI will be reported in this paper. The position resolutions and the detection efficiency of detectors have been obtained for

  10. DANSS: Detector of the reactor AntiNeutrino based on Solid Scintillator

    CERN Document Server

    Alekseev, I; Brudanin, V; Danilov, M; Egorov, V; Filosofov, D; Fomina, M; Hons, Z; Kazartsev, S; Kobyakin, A; Kuznetsov, A; Machikhiliyan, I; Medvedev, D; Nesterov, V; Olshevsky, A; Ponomarev, D; Rozova, I; Rumyantseva, N; Rusinov, V; Salamatin, A; Shevchik, Ye; Shirchenko, M; Shitov, Yu; Skrobova, N; Starostin, A; Svirida, D; Tarkovsky, E; Tikhomirov, I; Vlasek, J; Zhitnikov, I; Zinatulina, D

    2016-01-01

    The DANSS project is aimed at creating a relatively compact neutrino spectrometer which does not contain any flammable or other dangerous liquids and may therefore be located very close to the core of an industrial power reactor. As a result, it is expected that high neutrino flux would provide about 15,000 IBD interactions per day in the detector with a sensitive volume of 1 m$^3$. High segmentation of the plastic scintillator will allow to suppress a background down to a 1% level. Numerous tests performed with a simplified pilot prototype DANSSino under a 3 GW$_{th}$ reactor of the Kalinin NPP have demonstrated operability of the chosen design. The DANSS detector surrounded with a composite shield is movable by means of a special lifting gear, varying the distance to the reactor core in a range from 10 m to 12 m. Due to this feature, it could be used not only for the reactor monitoring, but also for fundamental research including short-range neutrino oscillations to the sterile state. Supposing one-year mea...

  11. Prospects of the search for neutrino bursts from Supernovae with Baksan Large Volume Scintillation Detector

    CERN Document Server

    Petkov, V B

    2015-01-01

    Observing a high-statistics neutrino signal from the supernova explosions in the Galaxy is a major goal of low-energy neutrino astronomy. The prospects for detecting all flavors of neutrinos and antineutrinos from the core-collapse supernova (ccSN) in operating and forthcoming large liquid scintillation detectors (LLSD) are widely discussed now. One of proposed LLSD is Baksan Large Volume Scintillation Detector (BLVSD). This detector will be installed at the Baksan Neutrino Observatory (BNO) of the Institute for Nuclear Research, Russian Academy of Sciences, at a depth of 4800 m.w.e. Low-energy neutrino astronomy is one of the main lines of research of the BLVSD.

  12. Development of a Compton camera for medical applications based on silicon strip and scintillation detectors

    Science.gov (United States)

    Krimmer, J.; Ley, J.-L.; Abellan, C.; Cachemiche, J.-P.; Caponetto, L.; Chen, X.; Dahoumane, M.; Dauvergne, D.; Freud, N.; Joly, B.; Lambert, D.; Lestand, L.; Létang, J. M.; Magne, M.; Mathez, H.; Maxim, V.; Montarou, G.; Morel, C.; Pinto, M.; Ray, C.; Reithinger, V.; Testa, E.; Zoccarato, Y.

    2015-07-01

    A Compton camera is being developed for the purpose of ion-range monitoring during hadrontherapy via the detection of prompt-gamma rays. The system consists of a scintillating fiber beam tagging hodoscope, a stack of double sided silicon strip detectors (90×90×2 mm3, 2×64 strips) as scatter detectors, as well as bismuth germanate (BGO) scintillation detectors (38×35×30 mm3, 100 blocks) as absorbers. The individual components will be described, together with the status of their characterization.

  13. Development of a Compton camera for medical applications based on silicon strip and scintillation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Krimmer, J., E-mail: j.krimmer@ipnl.in2p3.fr [Institut de Physique Nucléaire de Lyon, Université de Lyon, Université Lyon 1, CNRS/IN2P3 UMR 5822, 69622 Villeurbanne cedex (France); Ley, J.-L. [Institut de Physique Nucléaire de Lyon, Université de Lyon, Université Lyon 1, CNRS/IN2P3 UMR 5822, 69622 Villeurbanne cedex (France); Abellan, C.; Cachemiche, J.-P. [Aix-Marseille Université, CNRS/IN2P3, CPPM UMR 7346, 13288 Marseille (France); Caponetto, L.; Chen, X.; Dahoumane, M.; Dauvergne, D. [Institut de Physique Nucléaire de Lyon, Université de Lyon, Université Lyon 1, CNRS/IN2P3 UMR 5822, 69622 Villeurbanne cedex (France); Freud, N. [Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA - Lyon, Université Lyon 1, Centre Léon Bérard (France); Joly, B.; Lambert, D.; Lestand, L. [Clermont Université, Université Blaise Pascal, CNRS/IN2P3, Laboratoire de Physique Corpusculaire, BP 10448, F-63000 Clermont-Ferrand (France); Létang, J.M. [Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA - Lyon, Université Lyon 1, Centre Léon Bérard (France); Magne, M. [Clermont Université, Université Blaise Pascal, CNRS/IN2P3, Laboratoire de Physique Corpusculaire, BP 10448, F-63000 Clermont-Ferrand (France); and others

    2015-07-01

    A Compton camera is being developed for the purpose of ion-range monitoring during hadrontherapy via the detection of prompt-gamma rays. The system consists of a scintillating fiber beam tagging hodoscope, a stack of double sided silicon strip detectors (90×90×2 mm{sup 3}, 2×64 strips) as scatter detectors, as well as bismuth germanate (BGO) scintillation detectors (38×35×30 mm{sup 3}, 100 blocks) as absorbers. The individual components will be described, together with the status of their characterization.

  14. A large acceptance scintillator detector with wavelength shifting fibre read-out for search of eta-nucleus bound states

    CERN Document Server

    Kilian, K; Kirillov, Da; Kirillov, Di; Kolev, D; Kravcikova, M; Kutsarova, T; Lesiak, M; Lieb, J; Machner, H; Magiera, A; Maier, R; Martinská, G; Nedev, S; Piskunov, N; Prasuhn, D; Prottic, D; Ritman, J; Von Rossen, P; Roy, B J; Shukla, P; Sitnik, I; Siudak, R; Tsenov, R; Ulicny, M; Urbán, J; Vankova, G

    2007-01-01

    A large acceptance scintillator detector with wavelength shifting optical fibre readout has been designed and built to detect the decay particles of $\\eta$-nucleus bound system (the so-called $\\eta$-mesic nuclei), namely, protons and pions. The detector, named as ENSTAR detector, consists of 122 pieces of plastic scintillator of various shapes and sizes, which are arranged in a cylindrical geometry to provide particle identification, energy loss and coarse position information for these particles. A solid angle coverage of $\\sim$95% of total 4$\\pi$ is obtained in the present design of the detector. Monte Carlo phase space calculations performed to simulate the formation and decay of $\\eta$-mesic nuclei suggest that its decay particles, the protons and pions are emitted with an opening angle of 150$^\\circ \\pm 20^\\circ$, and with energies in the range of 25 to 300 MeV and 225 to 450 MeV respectively. The detailed GEANT simulations show that $\\sim$ 80 % of the decay particles (protons and pions) can be detected ...

  15. Discovery potential for supernova relic neutrinos with slow liquid scintillator detectors

    CERN Document Server

    Wei, Hanyu; Chen, Shaomin

    2016-01-01

    The detection of supernova relic neutrinos would provide a key support for our current understanding of stellar and cosmological evolution, and precise measurements of them would further give us an insight of the profound universe. In this paper we study the potential to detect supernova relic neutrinos using linear alkyl benzene, LAB, as a slow liquid scintillator, which features a good separation of Cherenkov and scintillation lights, thus providing a new ability in particle identification. We also address key issues of current experiments, including 1) the charged current background of atmospheric neutrinos in water Cherenkov detectors, and 2) the neutral current background of atmospheric neutrinos in typical liquid scintillator detectors. With LAB, a kiloton-scale detector, like the SNO, KamLAND, and the future Jinping neutrino detectors, with $\\mathcal{O}$(10) years of data, would have the sensitivity to discover supernova relic neutrinos, which is comparable to large-volume water Cherenkov, typical liqu...

  16. Detection of gamma-neutron radiation by solid-state scintillation detectors. Detection of gamma-neutron radiation by novel solid-state scintillation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Ryzhikov, V.; Grinyov, B.; Piven, L.; Onyshchenko, G.; Sidletskiy, O. [Institute for Scintillation Materials of the NAS of Ukraine, Kharkov, (Ukraine); Naydenov, S. [Institute for Single Crystals of the National Academy of Sciences of Ukraine, Kharkov, (Ukraine); Pochet, T. [DETEC-Europe, Vannes (France); Smith, C. [Naval Postgraduate School, Monterey, CA (United States)

    2015-07-01

    It is known that solid-state scintillators can be used for detection of both gamma radiation and neutron flux. In the past, neutron detection efficiencies of such solid-state scintillators did not exceed 5-7%. At the same time it is known that the detection efficiency of the gamma-neutron radiation characteristic of nuclear fissionable materials is by an order of magnitude higher than the efficiency of detection of neutron fluxes alone. Thus, an important objective is the creation of detection systems that are both highly efficient in gamma-neutron detection and also capable of exhibiting high gamma suppression for use in the role of detection of neutron radiation. In this work, we present the results of our experimental and theoretical studies on the detection efficiency of fast neutrons from a {sup 239}Pu-Be source by the heavy oxide scintillators BGO, GSO, CWO and ZWO, as well as ZnSe(Te, O). The most probable mechanism of fast neutron interaction with nuclei of heavy oxide scintillators is the inelastic scattering (n, n'γ) reaction. In our work, fast neutron detection efficiencies were determined by the method of internal counting of gamma-quanta that emerge in the scintillator from (n, n''γ) reactions on scintillator nuclei with the resulting gamma energies of ∼20-300 keV. The measured efficiency of neutron detection for the scintillation crystals we considered was ∼40-50 %. The present work included a detailed analysis of detection efficiency as a function of detector and area of the working surface, as well as a search for new ways to create larger-sized detectors of lower cost. As a result of our studies, we have found an unusual dependence of fast neutron detection efficiency upon thickness of the oxide scintillators. An explanation for this anomaly may involve the competition of two factors that accompany inelastic scattering on the heavy atomic nuclei. The transformation of the energy spectrum of neutrons involved in the (n, n

  17. A crystal identification method for monolithic phoswich detectors based on scintillation light distribution

    Science.gov (United States)

    Preziosi, E.; Pani, R.; Trigila, C.; Polito, C.; Bettiol, M.; Borrazzo, C.; Cinti, M. N.; Fabbri, A.; Pellegrini, R.; Pani, R.

    2016-12-01

    Phoswich detectors based on scintillation crystals are widely diffused for both PET and SPECT applications. In order to separate the signals arising from different layers many methods have been proposed in literature. Separation of the layers commonly relies on time discrimination or pulse height discrimination. In this work, by means of experimental measurement on a phoswich detector based on Lanthanum Bromide and Lutetium Fine Silicate monolithic crystals, a novel method allowing to separate signals coming from different layers has been evaluated. The main feature of this method, specifically developed for phoswich based on monolithic scintillation crystals, is the discrimination capability based on the scintillation light distribution shape. For this reason, the findings that will be shown could be easily extended to whatever combination of scintillator, independently from their decay time or light yield.

  18. Subnanosecond scintillation detector for high energy cosmic rays Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The task objective is to develop a gamma ray scintillator technology with subnanosecond temporal resolution and the capability to withstand unprecedented rates and...

  19. Photonic Crystals: Enhancing the Light Output of Scintillation Based Detectors

    CERN Document Server

    Knapitsch, Arno Richard

    A scintillator is a material which emits light when excited by ionizing radiation. Such materials are used in a diverse range of applications; From high energy particle physics experiments, X-ray security, to nuclear cameras or positron emission tomography. Future high-energy physics (HEP) experiments as well as next generation medical imaging applications are more and more pushing towards better scintillation characteristics. One of the problems in heavy scintillating materials is related to their high index of refraction. As a consequence, most of the scintillation light produced in the bulk material is trapped inside the crystal due to total internal reflection. The same problem also occurs with light emitting diodes (LEDs) and has for a long time been considered as a limiting factor for their overall efficiency. Recent developments in the area of nanophotonics were showing now that those limitations can be overcome by introducing a photonic crystal (PhC) slab at the outcoupling surface of the substrate. P...

  20. Cryogenic phonon-scintillation detectors with PMT readout for rare event search experiments

    Science.gov (United States)

    Zhang, X.; Lin, J.; Mikhailik, V. B.; Kraus, H.

    2016-06-01

    Cryogenic phonon-scintillation detectors (CPSD) for rare event search experiments require reliable, efficient and robust photon detectors that can resolve individual photons in a scintillation event. We report on a cryogenic detector containing a scintillating crystal, equipped with an NTD-Ge phonon sensor and a photon detector based on a low-temperature photomultiplier tube (PMT) that is powered by a Cockcroft-Walton generator. Here we present results from the characterisation of two detector modules, one with CaWO4, the other with CaMoO4 as scintillator. The energy resolutions (FWHM) at 122.1 keV for the scintillation/PMT channel are 19.9% and 29.7% respectively for CaWO4 and CaMoO4 while the energy resolutions (FWHM) for the phonon channels are 2.17 keV (1.8%) and 0.97 keV (0.79%). These characteristics compare favourably with other CPSDs currently used in cryogenic rare-event search experiments. The detection module with PMT readout benefits from the implementation of a well-understood, reliable, and commercially available component and improved time resolution, while retaining the major advantages of conventional CPSD, such as high sensitivity, resolving power and discrimination ability.

  1. Performance of SEM scintillation detector evaluated by modulation transfer function and detective quantum efficiency function.

    Science.gov (United States)

    Bok, Jan; Schauer, Petr

    2014-01-01

    In the paper, the SEM detector is evaluated by the modulation transfer function (MTF) which expresses the detector's influence on the SEM image contrast. This is a novel approach, since the MTF was used previously to describe only the area imaging detectors, or whole imaging systems. The measurement technique and calculation of the MTF for the SEM detector are presented. In addition, the measurement and calculation of the detective quantum efficiency (DQE) as a function of the spatial frequency for the SEM detector are described. In this technique, the time modulated e-beam is used in order to create well-defined input signal for the detector. The MTF and DQE measurements are demonstrated on the Everhart-Thornley scintillation detector. This detector was alternated using the YAG:Ce, YAP:Ce, and CRY18 single-crystal scintillators. The presented MTF and DQE characteristics show good imaging properties of the detectors with the YAP:Ce or CRY18 scintillator, especially for a specific type of the e-beam scan. The results demonstrate the great benefit of the description of SEM detectors using the MTF and DQE. In addition, point-by-point and continual-sweep e-beam scans in SEM were discussed and their influence on the image quality was revealed using the MTF.

  2. Compressive sensing of signals generated in plastic scintillators in a novel J-PET instrument

    Energy Technology Data Exchange (ETDEWEB)

    Raczyński, L., E-mail: lech.raczynski@ncbj.gov.pl [Świerk Computing Centre, National Centre for Nuclear Research, 05-400 Otwock-Świerk (Poland); Moskal, P. [Faculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, 30-059 Cracow (Poland); Kowalski, P.; Wiślicki, W. [Świerk Computing Centre, National Centre for Nuclear Research, 05-400 Otwock-Świerk (Poland); Bednarski, T.; Białas, P.; Czerwiński, E.; Gajos, A. [Faculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, 30-059 Cracow (Poland); Kapłon, Ł. [Faculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, 30-059 Cracow (Poland); Institute of Metallurgy and Materials Science of Polish Academy of Sciences, Cracow (Poland); Kochanowski, A. [Faculty of Chemistry, Jagiellonian University, 30-060 Cracow (Poland); Korcyl, G.; Kowal, J.; Kozik, T.; Krzemień, W.; Kubicz, E.; Niedźwiecki, Sz.; Pałka, M.; Rudy, Z.; Rundel, O.; Salabura, P. [Faculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, 30-059 Cracow (Poland); and others

    2015-06-21

    The J-PET scanner, which allows for single bed imaging of the whole human body, is currently under development at the Jagiellonian University. The discussed detector offers improvement of the Time of Flight (TOF) resolution due to the use of fast plastic scintillators and dedicated electronics allowing for sampling in the voltage domain of signals with durations of few nanoseconds. In this paper we show that recovery of the whole signal, based on only a few samples, is possible. In order to do that, we incorporate the training signals into the Tikhonov regularization framework and we perform the Principal Component Analysis decomposition, which is well known for its compaction properties. The method yields a simple closed form analytical solution that does not require iterative processing. Moreover, from the Bayes theory the properties of regularized solution, especially its covariance matrix, may be easily derived. This is the key to introduce and prove the formula for calculations of the signal recovery error. In this paper we show that an average recovery error is approximately inversely proportional to the number of acquired samples.

  3. Improving detector spatial resolution using pixelated scintillators with a barrier rib structure

    Science.gov (United States)

    Liu, Langechuan; Lu, Minghui; Cao, Wanqing; Peng, Luke; Chen, Arthur

    2016-03-01

    Indirect conversion flat panel detectors (FPDs) based on amorphous silicon (a-Si) technology are widely used in digital X-ray imaging. In such FPDs a scintillator layer is used for converting X-rays into visible light photons. However, the lateral spread of these photons inside the scintillator layer reduces spatial resolution of the FPD. In this study, FPDs incorporating pixelated scintillators with a barrier rib structure were developed to limit lateral spread of light photons thereby improving spatial resolution. For the pixelated scintillator, a two-dimensional barrier rib structure was first manufactured on a substrate layer, coated with reflective materials, and filled to the rim with the scintillating material of gadolinium oxysulfide (GOS). Several scintillator samples were fabricated, with pitch size varying from 160 to 280 μm and rib height from 200 to 280 μm. The samples were directly coupled to an a-Si flat panel photodiode array with a pitch of 200 μm to convert optical photons to electronic signals. With the pixelated scintillator, the detector modulation transfer function was shown to improve significantly (by 94% at 2 cycle/mm) compared to a detector using an unstructured GOS layer. However, the prototype does show lower sensitivity due to the decrease in scintillator fill factor. The preliminary results demonstrated the feasibility of using the barrier-rib structure to improve the spatial resolution of FPDs. Such an improvement would greatly benefit nondestructive testing applications where the spatial resolution is the most important parameter. Further investigation will focus on improving the detector sensitivity and exploring its medical applications.

  4. Multi-energy radiography on the basis of "scintillator-photodiode" detectors

    CERN Document Server

    Naydenov, S V; Grinyov, B V; Lisetskaya, E K; Kozin, D N; Opolonin, A D

    2003-01-01

    For reconstruction of the spatial structure and thicknesses of complex objects and materials, it is proposed to use multi-radiography with detection of X-ray or gamma-radiation by combined detector arrays of scintillator-photodiode type. Experimental studies have been carried out of the energy dependence of sensitivity of dual-energy inspection systems based on scintillators $ZnSe(Te)$ and $CsI(Tl)$.

  5. Application of Compressive Sensing Theory for the Reconstruction of Signals in Plastic Scintillators

    CERN Document Server

    Raczyński, L; Bednarski, T; Białas, P; Czerwiński, E; Kapłon, Ł; Kochanowski, A; Korcyl, G; Kowal, J; Kozik, T; Krzemień, W; Molenda, M; Moskal, P; Niedźwiecki, Sz; Pałka, M; Pawlik, M; Rudy, Z; Salabura, P; Sharma, N G; Silarski, M; Słomski, A; Smyrski, J; Strzelecki, A; Wiślicki, W; Zieliński, M

    2013-01-01

    Compressive Sensing theory says that it is possible to reconstruct a measured signal if an enough sparse representation of this signal exists in comparison to the number of random measurements. This theory was applied to reconstruct signals from measurements of plastic scintillators. Sparse representation of obtained signals was found using SVD transform.

  6. Measurement of (222)Rn by absorption in plastic scintillators and alpha/beta pulse shape discrimination.

    Science.gov (United States)

    Mitev, Krasimir K

    2016-04-01

    This work demonstrates that common plastic scintillators like BC-400, EJ-200 and SCSF-81 absorb radon and their scintillation pulse decay times are different for alpha- and beta-particles. This allows the application of pulse shape analysis for separation of the pulses of alpha- and beta-particles emitted by the absorbed radon and its progeny. It is shown that after pulse shape discrimination of beta-particles' pulses, the energy resolution of BC-400 and EJ-200 alpha spectra is sufficient to separate the peaks of (222)Rn, (218)Po and (214)Po and allows (222)Rn measurements that are unaffected by the presence of thoron ((220)Rn) in the environment. The alpha energy resolution of SCSF-81 in the experiments degrades due to imperfect collection of the light emitted inside the scintillating fibers. The experiments with plastic scintillation microspheres (PSM) confirm previous findings of other researchers that PSM have alpha-/beta-discrimination properties and show suitability for radon measurements. The diffusion length of radon in BC-400 and EJ-200 is determined. The pilot experiments show that the plastic scintillators are suitable for radon-in-soil-gas measurements. Overall, the results of this work suggest that it is possible to develop a new type of radon measurement instruments which employ absorption in plastic scintillators, pulse-shape discrimination and analysis of the alpha spectra. Such instruments can be very compact and can perform continuous, real-time radon measurements and thoron detection. They can find applications in various fields from radiation protection to earth sciences. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Combinatorial Screening of Advanced Scintillators for High Resolution X-ray Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Shifan; Tao, Dejie; Lynch, Michael; Yuan, Xianglong; Li, Yiqun

    2008-05-12

    The lack of efficient scintillators is a major problem for developing powerful x-ray detectors that are widely used in homeland security, industrial and scientific research. Intematix has developed and applied a high throughput screening process and corresponding crystal growth technology to significantly speed up the discovery process for new efficient scintillators. As a result, Intematix has invented and fabricated three new scintillators both in powder and bulk forms, which possess promising properties such as better radiation hardness and better matching for silicon diode.

  8. Combination of a silicon photodiode and a scintillator as a dose rate detector

    Energy Technology Data Exchange (ETDEWEB)

    Gilar, O. (Tesla, Premysleni (Czechoslovakia). Vyzkumny Ustav Pristroju Jaderne Techniky); Petr, I. (Ceske Vysoke Uceni Technicke, Prague (Czechoslovakia). Fakulta Jaderna a Fysikalne Inzenyrska)

    1985-03-16

    The combination of a silicon photodiode adjacent to a CsI(Tl) scintillator as a detector of ..gamma..-rays is described. Theoretical conclusions are verified by an experiment and prove that the photodiode absorption spectrum as well as the quantum efficiency can be varied by an appropriate photodiode technology. The contribution of scintillation photons emitted by the CsI(Tl) scintillator in the photon field can enhance the total photocurrent more than an order of magnitude compared to the current response of the photodiode alone, placed in a photon field of equal exposure rate.

  9. Scintillation neutron detectors based on solid-state photomultipliers and lightguides

    Energy Technology Data Exchange (ETDEWEB)

    Litvin, V. S., E-mail: vlitvin@inr.ru; Marin, V. N.; Karaevsky, S. K.; Trunov, D. N.; Axenov, S. N.; Stolyarov, A. A.; Sadykov, R. A. [Russian Academy of Sciences, Institute for Nuclear Research (Russian Federation)

    2016-01-15

    Neutron detectors based on scintillation screens ZnS(Ag)/LiF and solid-state photomultipliers have been developed. Lightguides are used to collect light. The application of a coincidence scheme provides a low dark count and a neutron detection efficiency as high as 70%. A scheme of x-y neutron detector based on wavelength shifting fibers is also proposed. Tests of the proposed versions of detectors in a neutron beam have shown their efficiency.

  10. A region segmentation based algorithm for building crystal position lookup table in scintillation detector

    CERN Document Server

    Wang, Hai Peng; Liu, Shuang Quan; Fan, Xin; Cao, Xue Xiang; Chai, Pei; Shan, Bao Ci

    2014-01-01

    In scintillation detector, scintillation crystals are typically made into 2-dimension modular array. The location of incident gamma-ray need be calibrated due to spatial response nonlinearity. Generally, position histograms, the characteristic flood response of scintillation detectors, are used for position calibration. In this paper, a position calibration method based on crystal position lookup table which maps the inaccurate location calculated by Anger logic to the exact hitting crystal position has been proposed, Firstly, position histogram is segmented into disconnected regions. Then crystal marking points are labeled by finding the centroids of regions. Finally, crystal boundaries are determined and crystal position lookup table is generated. The scheme is evaluated by the whole-body PET scanner and breast dedicated SPECT detector developed by Institute of High Energy Physics, Chinese Academy of Sciences. The results demonstrate that the algorithm is accurate, efficient, robust and general purpose.

  11. Compensational scintillation detector with a flat energy response for flash X-ray measurements

    Science.gov (United States)

    Chen, Liang; Ouyang, Xiaoping; Liu, Bin; Liu, Jinliang; Quan, Lin; Zhang, Zhongbing

    2013-01-01

    To measure the intensity of flash X-ray sources directly, a novel scintillation detector with a fast time response and flat energy response is developed by combining film scintillators of doped ZnO crystal and fast organic scintillator together. Through compensation design, the dual-scintillator detector (DSD) achieved a flat energy response to X-rays from tens of keV to several MeV, and sub-nanosecond time response by coupling to ultrafast photo-electronic devices. A prototype detector was fabricated according to the theoretical design; it employed ZnO:In and EJ228 with thicknesses of 0.3 mm and 0.1 mm, respectively. The energy response of this detector was tested on monoenergetic X-ray and γ-ray sources. The detector performs very well with a sensitivity fluctuation below 5% for 8 discrete energy points within the 40-250 keV energy region and for other energies of 662 keV and 1.25 MeV as well, showing good accordance with the theoretical design. Additionally, the detector works properly for the application to the flash X-ray radiation field absolute intensity measurement. This DSD may be very useful for the diagnosis of time-resolved dynamic physical processes of flash X-ray sources without knowing the exact energy spectrum.

  12. A scintillating gas detector for 2D dose measurements in clinical carbon beams.

    Science.gov (United States)

    Seravalli, E; de Boer, M; Geurink, F; Huizenga, J; Kreuger, R; Schippers, J M; van Eijk, C W E; Voss, B

    2008-09-07

    A two-dimensional position sensitive dosimetry system based on a scintillating gas detector has been developed for pre-treatment verification of dose distributions in hadron therapy. The dosimetry system consists of a chamber filled with an Ar/CF4 scintillating gas mixture, inside which two cascaded gas electron multipliers (GEMs) are mounted. A GEM is a thin kapton foil with copper cladding structured with a regular pattern of sub-mm holes. The primary electrons, created in the detector's sensitive volume by the incoming beam, drift in an electric field towards the GEMs and undergo gas multiplication in the GEM holes. During this process, photons are emitted by the excited Ar/CF4 gas molecules and detected by a mirror-lens-CCD camera system. Since the amount of emitted light is proportional to the dose deposited in the sensitive volume of the detector by the incoming beam, the intensity distribution of the measured light spot is proportional to the 2D hadron dose distribution. For a measurement of a 3D dose distribution, the scintillating gas detector is mounted at the beam exit side of a water-bellows phantom, whose thickness can be varied in steps. In this work, the energy dependence of the output signal of the scintillating gas detector has been verified in a 250 MeV/u clinical 12C ion beam by means of a depth-dose curve measurement. The underestimation of the measured signal at the Bragg peak depth is only 9% with respect to an air-filled ionization chamber. This is much smaller than the underestimation found for a scintillating Gd2O2S:Tb ('Lanex') screen under the same measurement conditions (43%). Consequently, the scintillating gas detector is a promising device for verifying dose distributions in high LET beams, for example to check hadron therapy treatment plans which comprise beams with different energies.

  13. A Novel Particle Detector: Quantum Dot Doped Liquid Scintillator

    Science.gov (United States)

    Winslow, Lindley; Conrad, Janet; Jerry, Ruel

    2010-02-01

    Quantum dots are semiconducting nanocrystals. When excited by light shorter then their characteristic wavelength, they re-emit in a narrow band around this wavelength. The size of the quantum is proportional to the characteristic wavelength so they can be tuned for many applications. CdS quantum dots are made in wavelengths from 360nm to 460nm, a perfect range for the sensitivity of photo-multiplier tubes. The synthesis of quantum dots automatically leaves them in toluene, a good organic scintillator and Cd is a particularly interesting material as it has one of the highest thermal neutron cross sections and has several neutrinoless double beta decay and double electron capture isotopes. The performance of quantum dot loaded scintillator compared to standard scintillators is measured and some unique properties presented. )

  14. PoGOLino: a scintillator-based balloon-borne neutron detector

    CERN Document Server

    Kole, Merlin; Fukazawa, Yasushi; Fukuda, Kentaro; Ishizu, Sumito; Jackson, Miranda; Kamae, Tune; Kawaguchi, Noriaki; Kawano, Takafumi; Kiss, Mozsi; Moretti, Elena; Pearce, Mark; Rydström, Stefan; Takahashi, Hiromitsu; Yanagida, Takayuki

    2014-01-01

    PoGOLino is a balloon-borne scintillator-based experiment developed to study the largely unexplored high altitude neutron environment at high geomagnetic latitudes. The instrument comprises two detectors that make use of LiCAF, a novel neutron sensitive scintillator, sandwiched by BGO crystals for background reduction. The experiment was launched on March 20th 2013 from the Esrange Space Centre, Northern Sweden (geomagnetic latitude of $65^\\circ$), for a three hour flight during which the instrument took data up to an altitude of 30.9 km. The detector design and ground calibration results are presented together with the measurement results from the balloon flight.

  15. A scintillator based muon and KLong detector for the Belle II experiment

    CERN Document Server

    Aushev, T; Chilikin, K; Chistov, R; Danilov, M; Katrenko, P; Mizuk, R; Pakhlova, G; Pakhlov, P; Rusinov, V; Solovieva, E; Tarkovsky, E; Tikhomirov, I; Uglov, T

    2014-01-01

    A new muon and K_Long detector based on scintillators will be used for the endcap and inner barrel regions in the Belle II experiment, currently under construction. The increased luminosity of the e+e- SuperKEKB collider entails challenging detector requirements. We demonstrate that relatively inexpensive polystyrene scintillator stips with wave length shifting fibers ensure a sufficient light yield at the Silcon PhotoMultiplier (SiPM) photodetector, are robust and provide improved physics performance for the Belle II experiment compared to its predecessor, Belle.

  16. Comparative analysis of pulse shape discrimination methods in a {sup 6}Li loaded plastic scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Balmer, Matthew J.I., E-mail: m.balmer@lancaster.ac.uk [Department of Engineering, Lancaster University, LA1 4YR (United Kingdom); Gamage, Kelum A.A. [Department of Engineering, Lancaster University, LA1 4YR (United Kingdom); Taylor, Graeme C. [Neutron Metrology Group, National Physical Laboratory, Teddington, TW11 0LW (United Kingdom)

    2015-07-11

    Three algorithms for discriminating between fast neutrons, thermal neutrons and gamma rays in a {sup 6}Li loaded plastic scintillator have been compared. Following a literature review of existing pulse shape discrimination techniques, the performance of the charge comparison method, triangular filtering and frequency gradient analysis were investigated in this work. The scintillator was exposed to three different mixed gamma/neutron radiation fields. The figure of merit of neutron/gamma separation was investigated over a broad energy range, as well as for the neutron capture energy region. After optimisation, all three methods were found to perform similarly in terms of neutron/gamma separation.

  17. First-principles Electronic Structure Calculations for Scintillation Phosphor Nuclear Detector Materials

    Science.gov (United States)

    Canning, Andrew

    2013-03-01

    Inorganic scintillation phosphors (scintillators) are extensively employed as radiation detector materials in many fields of applied and fundamental research such as medical imaging, high energy physics, astrophysics, oil exploration and nuclear materials detection for homeland security and other applications. The ideal scintillator for gamma ray detection must have exceptional performance in terms of stopping power, luminosity, proportionality, speed, and cost. Recently, trivalent lanthanide dopants such as Ce and Eu have received greater attention for fast and bright scintillators as the optical 5d to 4f transition is relatively fast. However, crystal growth and production costs remain challenging for these new materials so there is still a need for new higher performing scintillators that meet the needs of the different application areas. First principles calculations can provide a useful insight into the chemical and electronic properties of such materials and hence can aid in the search for better new scintillators. In the past there has been little first-principles work done on scintillator materials in part because it means modeling f electrons in lanthanides as well as complex excited state and scattering processes. In this talk I will give an overview of the scintillation process and show how first-principles calculations can be applied to such systems to gain a better understanding of the physics involved. I will also present work on a high-throughput first principles approach to select new scintillator materials for fabrication as well as present more detailed calculations to study trapping process etc. that can limit their brightness. This work in collaboration with experimental groups has lead to the discovery of some new bright scintillators. Work supported by the U.S. Department of Homeland Security and carried out under U.S. Department of Energy Contract no. DE-AC02-05CH11231 at Lawrence Berkeley National Laboratory.

  18. Data analysis in solar neutrinos liquid-scintillator detectors

    Energy Technology Data Exchange (ETDEWEB)

    Testera, G. [INFN, Genova (Italy)

    2016-04-15

    This paper focuses on the description of some of the methods developed to extract the solar neutrino signal from the background by the two running experiments (Borexino and Kamland) based on the use of a large volume of liquid scintillator. (orig.)

  19. Advanced Scintillator Detector Concept (ASDC): A Concept Paper on the Physics Potential of Water-Based Liquid Scintillator

    CERN Document Server

    Alonso, J R; Bergevin, M; Bernstein, A; Bignell, L; Blucher, E; Calaprice, F; Conrad, J M; Descamps, F B; Diwan, M V; Dwyer, D A; Dye, S T; Elagin, A; Feng, P; Grant, C; Grullon, S; Hans, S; Jaffe, D E; Kettell, S H; Klein, J R; Lande, K; Learned, J G; Luk, K B; Maricic, J; Marleau, P; Mastbaum, A; McDonough, W F; Oberauer, L; Gann, G D Orebi; Rosero, R; Rountree, S D; Sanchez, M C; Shaevitz, M H; Shokair, T M; Smy, M B; Strait, M; Svoboda, R; Tolich, N; Vagins, M R; van Bibber, K A; Viren, B; Vogelaar, R B; Wetstein, M J; Winslow, L; Wonsak, B; Worcester, E T; Wurm, M; Yeh, M; Zhang, C

    2014-01-01

    The recent development of Water-based Liquid Scintillator (WbLS), and the concurrent development of high-efficiency and high-precision-timing light sensors, has opened up the possibility for a new kind of large-scale detector capable of a very broad program of physics. The program would include determination of the neutrino mass hierarchy and observation of CP violation with long-baseline neutrinos, searches for proton decay, ultra-precise solar neutrino measurements, geo- and supernova neutrinos including diff?use supernova antineutrinos, and neutrinoless double beta decay. We outline here the basic requirements of the Advanced Scintillation Detector Concept (ASDC), which combines the use of WbLS, doping with a number of potential isotopes for a range of physics goals, high efficiency and ultra-fast timing photosensors, and a deep underground location. We are considering such a detector at the Long Baseline Neutrino Facility (LBNF) far site, where the ASDC could operate in conjunction with the liquid argon t...

  20. Three-dimensional photograph of electron tracks through a plastic scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Filipenko, Mykhaylo; Hufschmidt, Patrick; Anton, Gisela; Gleixner, Thomas; Wagenpfeil, Michael; Michel, Thilo [University of Erlangen-Nuremberg, Erlangen Centre for Astroparticle Physics, Erlangen (Germany); Iskhakov, Timur; Leuchs, Gerd [Max-Planck Institute for the Science of Light, Erlangen (Germany); Campbell, Michael; Tick, Timo [European Organization for Nuclear Research, CERN, Geneve 23 (Switzerland); Vallerga, John [University of California, Experimental Astrophysics Group, Space Science Laboratory, Berkeley, CA (United States)

    2014-11-15

    The reconstruction of particle trajectories makes it possible to distinguish between different types of charged particles. In high-energy physics, where trajectories are rather long (several meters), large size trackers must be used to achieve sufficient position resolution. However, in low-background experiments like the search for neutrinoless double beta decay, tracks are rather short (some mm to several cm, depending on the detector in use) and three-dimensional trajectories could only be resolved in gaseous time-projection chambers so far. For detectors of a large volume of around one cubic meter (large in the scope of neutrinoless double beta search) and therefore large drift distances (several decimeters to 1 m), this technique is limited by diffusion and repulsion of charge carriers. In this work we present a ''proof-of-principle'' experiment for a new method of the three-dimensional tracking of charged particles by scintillation light: we used a setup consisting of a scintillator, mirrors, lenses, and a novel imaging device (the hybrid photon detector) in order to image two projections of electron tracks through the scintillator. We took data at the T-22 beamline at DESY with relativistic electrons with a kinetic energy of 5 GeV and from this data successfully reconstructed their three-dimensional propagation path in the scintillator. With our setup we achieved a position resolution in the range of 170-248 μm. (orig.)

  1. Study of Scintillator thickness optimization of lens-coupled X-ray imaging detectors

    Science.gov (United States)

    Xie, H.; Du, G.; Deng, B.; Chen, R.; Xiao, T.

    2016-03-01

    Lens-coupled X-ray in-direct imaging detectors are very popular for high-resolution X-ray imaging at the third generation synchrotron radiation facilities. This imaging system consists of a scintilator producing a visible-light image of X-ray beam, a microscope objective, a mirror reflecting at 90° and a CCD camera. When the thickness of the scintillator is matched with the numerical aperture (NA) of the microscope objective, the image quality of experimental results will be improved obviously. This paper used an imaging system at BL13W beamline of Shanghai Synchrotron Radiation Facility (SSRF) to study the matching relation between the scintillator thickness and the NA of the microscope objective with a real sample. By use of the matching relation between the scintillator thickness and the NA of the microscope objective, the optimal imaging results have been obtained.

  2. Improved Scintillation Detector Performance via a Method of Enhanced Layered Coatings

    Science.gov (United States)

    Wakeford, Daniel T.; Tornga, Shawn R.; Adams, Jillian C.; Trautschold, Olivia C.; Hehlen, Markus P.

    2017-07-01

    Increasing demand for better detection performance with a simultaneous reduction in size, weight and power consumption has motivated the use of compact semiconductors as photo-converters for many gamma-ray and neutron scintillators. The spectral response of devices such as silicon avalanche photodiodes (APDs) is poorly matched to many common high-performance scintillators. We have developed a generalized analytical method that utilizes an optical reference database to match scintillator luminescence to the excitation spectrum of high quantum efficiency semiconductor detectors. This is accomplished by the fabrication and application of a series of high quantum yield, short fluorescence lifetime, wavelength-shifting coatings. We show here a 22% increase in photoelectron collection and a 10% improvement in energy resolution when applying a layered coating to an APD-coupled, cerium-doped, yttrium oxyorthosilicate (YSO:Ce) scintillator. Wavelength-shifted radio-luminescence emission and rise time analysis are also discussed.

  3. A fast microchannel plate-scintillator detector for velocity map imaging and imaging mass spectrometry.

    Science.gov (United States)

    Winter, B; King, S J; Brouard, M; Vallance, C

    2014-02-01

    The time resolution achievable using standard position-sensitive ion detectors, consisting of a chevron pair of microchannel plates coupled to a phosphor screen, is primarily limited by the emission lifetime of the phosphor, around 70 ns for the most commonly used P47 phosphor. We demonstrate that poly-para-phenylene laser dyes may be employed extremely effectively as scintillators, exhibiting higher brightness and much shorter decay lifetimes than P47. We provide an extensive characterisation of the properties of such scintillators, with a particular emphasis on applications in velocity-map imaging and microscope-mode imaging mass spectrometry. The most promising of the new scintillators exhibits an electron-to-photon conversion efficiency double that of P47, with an emission lifetime an order of magnitude shorter. The new scintillator screens are vacuum stable and show no signs of signal degradation even over longer periods of operation.

  4. A time resolution study with a plastic scintillator read out by a Geiger-mode Avalanche Photodiode

    Science.gov (United States)

    Stoykov, A.; Scheuermann, R.; Sedlak, K.

    2012-12-01

    In this work we attempt to establish the best time resolution attainable with a scintillation counter consisting of a plastic scintillator read out by a Geiger-mode Avalanche Photodiode. The measured time resolution is inversely proportional to the square root of the energy deposited in the scintillator, and scales to σ=18 ps at 1 MeV. This result competes with the best ones reported for photomultiplier tubes.

  5. A time resolution study with a plastic scintillator read out by a Geiger-mode Avalanche Photodiode

    Energy Technology Data Exchange (ETDEWEB)

    Stoykov, A., E-mail: alexey.stoykov@psi.ch [Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Scheuermann, R.; Sedlak, K. [Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland)

    2012-12-11

    In this work we attempt to establish the best time resolution attainable with a scintillation counter consisting of a plastic scintillator read out by a Geiger-mode Avalanche Photodiode. The measured time resolution is inversely proportional to the square root of the energy deposited in the scintillator, and scales to {sigma}=18ps at 1 MeV. This result competes with the best ones reported for photomultiplier tubes.

  6. A time-resolution study with a plastic scintillator read out by a Geiger-mode Avalanche Photodiode

    CERN Document Server

    Stoykov, A; Sedlak, K

    2011-01-01

    In this work we attempt to establish the best time resolution attainable with a scintillation counter consisting of a plastic scintillator read out by a Geiger-mode Avalanche Photodiode. The measured time resolution is inversely proportional to the square root of the energy deposited in the scintillator, and scales to 18ps (sigma) at 1MeV. This result competes with the best ones reported for photomultiplier tubes.

  7. A comparison of CsI:Tl and GOS in a scintillator-CCD detector for nuclear medicine imaging

    Science.gov (United States)

    Bugby, S. L.; Jambi, L. K.; Lees, J. E.

    2016-09-01

    A number of portable gamma cameras for medical imaging use scintillator-CCD based detectors. This paper compares the performance of a scintillator-CCD based portable gamma camera with either a columnar CsI:Tl or a pixelated GOS scintillator installed. The CsI:Tl scintillator has a sensitivity of 40% at 140.5 keV compared to 54% with the GOS scintillator. The intrinsic spatial resolution of the pixelated GOS detector was 1.09 mm, over 4 times poorer than for CsI:Tl. Count rate capability was also found to be significantly lower when the GOS scintillator was used. The uniformity was comparable for both scintillators.

  8. The array of scintillation detectors with natural boron for EAS neutrons investigations

    Science.gov (United States)

    Gromushkin, D. M.; Bogdanov, F. A.; Khokhlov, S. S.; Kokoulin, R. P.; Kompaniets, K. G.; Petrukhin, A. A.; Shulzhenko, I. A.; Stenkin, Yu. V.; Yashin, I. I.; Yurin, K. O.

    2017-07-01

    The new URAN array has been constructed in the National Research Nuclear University MEPhI (Moscow, Russia). It is aimed at studying of primary cosmic rays in the "knee" region of energy spectrum and detects neutrons produced in interactions of EAS particles with nuclei of atmosphere or matter. The array consists of 72 detectors based on the scintillator with natural boron. Scintillator represents a silicon plate with the granules of ZnS(Ag) and B2O3 mixture. The area of the detector is 0.36 sq. m. Detectors are located on two roofs of the MEPhI laboratory buildings and are combined into clusters of 12 detectors. The structure and the main elements of the URAN array are described.

  9. SNM detection by means of thermal neutron interrogation and a liquid scintillation detector

    Science.gov (United States)

    Ocherashvili, A.; Roesgen, E.; Beck, A.; Caspi, E. N.; Mosconi, M.; Crochemore, J.-M.; Pedersen, B.

    2012-03-01

    The feasibility of using a pulsed neutron generator in a graphite assembly together with a single liquid scintillation detector for the detection of special nuclear materials is investigated. Thermal source neutrons induce fission in fissile material present in the sample. By means of pulse shape discrimination the detector signals from fast fission neutrons are easily identified among the signals from gamma rays and the interrogating thermal neutrons. The method has potential in applications for detection of special nuclear materials in shielded containers.

  10. The research program of the Liquid Scintillation Detector (LSD) in the Mont Blanc Laboratory

    Science.gov (United States)

    Dadykin, V. L.; Yakushev, V. F.; Korchagin, P. V.; Korchagin, V. B.; Malgin, A. S.; Ryassny, F. G.; Ryazhskaya, O. G.; Talochkin, V. P.; Zatsepin, G. T.; Badino, G.

    1985-01-01

    A massive (90 tons) liquid scintillation detector (LSD) has been running since October 1984 in the Mont Blanc Laboratory at a depth of 5,200 hg/sq cm of standard rock. The research program of the experiment covers a variety of topics in particle physics and astrophysics. The performance of the detector, the main fields of research are presented and the preliminary results are discussed.

  11. Ticor-based scintillation detectors for detection of mixed radiation

    CERN Document Server

    Litvinov, L A; Kolner, V B; Ryzhikov, V D; Volkov, V G; Tarasov, V A; Zelenskaya, O V

    2002-01-01

    Detection of mixed radiation of thermal neutrons and gamma-rays have been realized using a new ceramic material based on small-crystalline long-wave scintillator alpha-Al sub 2 O sub 3 :Ti (Ticor) and lithium fluoride. Characteristics are presented for scintillators with Si-PIN-PD type photoreceivers and PMT under sup 2 sup 3 sup 9 Pu alpha-particles, sup 2 sup 0 sup 7 Bi internal conversion electrons,as well as sup 2 sup 4 sup 1 Am and sup 1 sup 3 sup 7 Cs gamma-quanta. Detection efficiency of thermal neutron is estimated for composite materials based on Ticor and lithium fluoride.

  12. Fast scintillation timing detector using proportional-mode avalanche photodiode for nuclear resonant scattering experiments in high-energy synchrotron X-ray region

    Science.gov (United States)

    Inoue, Keisuke; Kishimoto, Shunji

    2016-01-01

    To obtain both a high count rate of >107 s-1 and a detection efficiency sufficient for high-energy X-rays of >30 keV, we propose a scintillation timing detector using a proportional-mode silicon avalanche photodiode (Si-APD) for synchrotron radiation nuclear resonant scattering. We here present results obtained with a prototype detector using a lead-loaded plastic scintillator (EJ-256) mounted on a proportional-mode Si-APD (active area size: 3 mm in diameter). The detector was operated at ‒35 °C for a better signal-to-noise ratio. Using synchrotron X-rays of 67.41 keV, which is the same energy as the first excited level of 61Ni, we successfully measured pulse-height and time spectra of the scintillation light. A good time resolution of 0.50±0.06 ns (full width at half-maximum) was obtained for 67.41 keV X-rays with a scintillator 3 mm in diameter and 2 mm thick.

  13. New scintillators for focal plane detectors in gamma-ray missions

    NARCIS (Netherlands)

    Buis, Ernst-Jan; Beijersbergen, Marco; Kraft, Stefan; Owens, Alan; Quarati, Francesco; Brandenburg, Sytze; Ostendorf, Reint

    2005-01-01

    Recent developments of cerium-doped lanthanum-halide scintillators like LaBr3:Ce show a remarkable performance in gamma-ray spectroscopy. When high energy resolution in combination with stopping power is required they provide excellent gamma-ray detector candidates for the use in space missions. Mor

  14. Affect of Distinguishing of Neutron and Gamma for Liquid Scintillation Detector by Methods of Baseline Compensation

    Institute of Scientific and Technical Information of China (English)

    LI; Wei; LIU; Yi-na; LI; Chun-juan; WANG; Zhi-qiang; CHEN; Jun; LUO; Hai-long; ZHANG; Wei-hua; XU; Kun

    2015-01-01

    Most scintillation detectors are sensitive both for neutron and photon.Usually,there are photon in neutron fields which is coming from neutron source or reacting by neutron and materials around,so you must concern about the affect by photon which is below 10MeV.There will be a big effect for distinguishing

  15. Monte Carlo based calibration of scintillation detectors for laboratory and in situ gamma ray measurements

    NARCIS (Netherlands)

    van der Graaf, E. R.; Limburg, J.; Koomans, R. L.; Tijs, M.

    2011-01-01

    The calibration of scintillation detectors for gamma radiation in a well characterized setup can be transferred to other geometries using Monte Carlo simulations to account for the differences between the calibration and the other geometry. In this study a calibration facility was used that is const

  16. Development of a thermal neutron detector based on scintillating fibers and silicon photomultipliers.

    Science.gov (United States)

    Barbagallo, Massimo; Cosentino, Luigi; Greco, Giuseppe; Montereali, Rosa Maria; Pappalardo, Alfio; Scirè, Carlotta; Scirè, Sergio; Vincenti, Maria Aurora; Finocchiaro, Paolo

    2010-09-01

    We propose a technique for thermal neutron detection, based on a (6)Li converter placed in front of scintillating fibers readout by means of silicon photomultipliers. Such a technique allows building cheap and compact detectors and dosimeters, thus possibly opening new perspectives in terms of granular monitoring of neutron fluxes as well as space-resolved neutron detection.

  17. Monte Carlo based calibration of scintillation detectors for laboratory and in situ gamma ray measurements

    NARCIS (Netherlands)

    van der Graaf, E. R.; Limburg, J.; Koomans, R. L.; Tijs, M.

    The calibration of scintillation detectors for gamma radiation in a well characterized setup can be transferred to other geometries using Monte Carlo simulations to account for the differences between the calibration and the other geometry. In this study a calibration facility was used that is

  18. Quenching Factor for Low Energy Nuclear Recoils in a Plastic Scintillator

    CERN Document Server

    Reichhart, L; Araujo, H M; Barnes, E J; Belov, V A; Burenkov, A A; Chepel, V; Currie, A; DeViveiros, L; Edwards, B; Francis, V; Ghag, C; Hollingsworth, A; Horn, M; Kalmus, G E; Kobyakin, A S; Kovalenko, A G; Lebedenko, V N; Lindote, A; Lopes, M I; Luscher, R; Majewski, P; Murphy, A St J; Neves, F; Paling, S M; da Cunha, J Pinto; Preece, R; Quenby, J J; Scovell, P R; Silva, C; Solovov, V N; Smith, N J T; Smith, P F; Stekhanov, V N; Sumner, T J; Thorne, C; Walker, R J

    2011-01-01

    Plastic scintillators are widely used in industry, medicine and scientific research, including nuclear and particle physics. Although one of their most common applications is in neutron detection, experimental data on their response to low-energy nuclear recoils are scarce. Here, the relative scintillation efficiency for neutron-induced nuclear recoils in a polystyrene-based plastic scintillator (UPS-923A) is presented, exploring recoil energies between 125 keV and 850 keV. Monte Carlo simulations, incorporating light collection efficiency and energy resolution effects, are used to generate neutron scattering spectra which are matched to observed distributions of scintillation signals to parameterise the energy-dependent quenching factor. At energies above 300 keV the dependence is reasonably described using the semi-empirical formulation of Birks and a kB factor of (0.014+/-0.002) g/MeVcm^2 has been determined. Below that energy the measured quenching factor falls more steeply than predicted by the Birks for...

  19. Investigation of behavior of scintillator detector of Alborz observatory array using Monte Carlo method with Geant4 code

    Directory of Open Access Journals (Sweden)

    M. Abbasian Motlagh

    2014-04-01

    Full Text Available For their appropriate temporal resolution, scintillator detectors are used in the Alborz observatory. In this work, the behavior of the scintillation detectors for the passage of electrons with different energies and directions were studied using the simulation code GEANT4. Pulse shapes of scintillation light, and such characteristics as the total number of photons, the rise time and the falling time for the optical pulses were computed for the passage of electrons with energies of 10, 100 and 1000 MeV. Variations of the characteristics of optical pulse of scintillation with incident angle and the location of electrons were also investigated

  20. Monte Carlo simulation of a very high resolution thermal neutron detector composed of glass scintillator microfibers.

    Science.gov (United States)

    Song, Yushou; Conner, Joseph; Zhang, Xiaodong; Hayward, Jason P

    2016-02-01

    In order to develop a high spatial resolution (micron level) thermal neutron detector, a detector assembly composed of cerium doped lithium glass microfibers, each with a diameter of 1 μm, is proposed, where the neutron absorption location is reconstructed from the observed charged particle products that result from neutron absorption. To suppress the cross talk of the scintillation light, each scintillating fiber is surrounded by air-filled glass capillaries with the same diameter as the fiber. This pattern is repeated to form a bulk microfiber detector. On one end, the surface of the detector is painted with a thin optical reflector to increase the light collection efficiency at the other end. Then the scintillation light emitted by any neutron interaction is transmitted to one end, magnified, and recorded by an intensified CCD camera. A simulation based on the Geant4 toolkit was developed to model this detector. All the relevant physics processes including neutron interaction, scintillation, and optical boundary behaviors are simulated. This simulation was first validated through measurements of neutron response from lithium glass cylinders. With good expected light collection, an algorithm based upon the features inherent to alpha and triton particle tracks is proposed to reconstruct the neutron reaction position in the glass fiber array. Given a 1 μm fiber diameter and 0.1mm detector thickness, the neutron spatial resolution is expected to reach σ∼1 μm with a Gaussian fit in each lateral dimension. The detection efficiency was estimated to be 3.7% for a glass fiber assembly with thickness of 0.1mm. When the detector thickness increases from 0.1mm to 1mm, the position resolution is not expected to vary much, while the detection efficiency is expected to increase by about a factor of ten.

  1. Test of a single module of the J-PET scanner based on plastic scintillators

    CERN Document Server

    Moskal, P; Bednarski, T; Czerwiński, E; Kapłon, Ł; Kubicz, E; Moskal, I; Pawlik-Niedźwiecka, M; Sharma, N G; Silarski, M; Zieliński, M; Zoń, N; Białas, P; Gajos, A; Kochanowski, A; Korcyl, G; Kowal, J; Kowalski, P; Kozik, T; Krzemień, W; Molenda, M; Pałka, M; Raczyński, L; Rudy, Z; Salabura, P; Słomski, A; Smyrski, J; Strzelecki, A; Wieczorek, A; Wiślicki, W

    2014-01-01

    Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a method allowing application of plastic scintillators for the detection of low energy gamma quanta. In this article we report on tests of a single detection module built out from BC-420 plastic scintillator strip (with dimensions of 5x19x300mm^3) read out at two ends by Hamamatsu R5320 photomultipliers. The measurements were performed using collimated beam of annihilation quanta from the 68Ge isotope and applying the Serial Data Analyzer (Lecroy SDA6000A) which enabled sampling of signals with 50ps intervals. The time resolution of the prototype module was established to be better than 80ps (sigma) for a single level discrimination. The spatial resolution of the determination of the hit position along the strip was determined to be about 0.93cm (sigma) for the annihilation quanta...

  2. Digital Gamma-Neutron Discrimination with Organic Plastic Scintillator EJ 299-33

    Directory of Open Access Journals (Sweden)

    Nyibule S.

    2014-07-01

    Full Text Available The neutron / gamma pulse shape discrimination (PSD is measured for the newly dis- covered plastic scintillator EJ 299-33 using a fast digitizer DDC10. This plastic scin- tillator (EJ 299-33 discovered by Lawrence Livermore National Laboratory(LLNL is now commercially available by Eljen Technology. Some of its properties include light output emission efficiency of 56 / 100 (of Anthracene, wavelength of maximum emis- sion of 420 nm, C:H ratio of 1:1.06 and density of 1.08 g / cm 3 . The PSD between neutrons and gamma rays in this plastic scintillator is studied using a 5.08-cm diameter by 5.08-cm thick sample irradiated by a neutron-gamma source AmBe-241 and em- ploying charge integration method. The results show that EJ 299-33 has a very good PSD, having a figure of merit of approximately 0.80, 2.5 and 3.09 at 100 KeVee, 450 KeVee and 750 KeVee light outputs respectively. The performance of this new material is compared to that of a liquid scintillator with a well proven excellent PSD performance NE213, having a figure of merit of 0.93, 2.95 and 3.30 at 100 KeVee, 450 KeVee and 750 KeVee respectively. The PSD performance of EJ 299-33 is found to be comparable to that of NE 213.

  3. Evaluation of Large Volume SrI2(Eu) Scintillator Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Sturm, B W; Cherepy, N J; Drury, O B; Thelin, P A; Fisher, S E; Magyar, A F; Payne, S A; Burger, A; Boatner, L A; Ramey, J O; Shah, K S; Hawrami, R

    2010-11-18

    There is an ever increasing demand for gamma-ray detectors which can achieve good energy resolution, high detection efficiency, and room-temperature operation. We are working to address each of these requirements through the development of large volume SrI{sub 2}(Eu) scintillator detectors. In this work, we have evaluated a variety of SrI{sub 2} crystals with volumes >10 cm{sup 3}. The goal of this research was to examine the causes of energy resolution degradation for larger detectors and to determine what can be done to mitigate these effects. Testing both packaged and unpackaged detectors, we have consistently achieved better resolution with the packaged detectors. Using a collimated gamma-ray source, it was determined that better energy resolution for the packaged detectors is correlated with better light collection uniformity. A number of packaged detectors were fabricated and tested and the best spectroscopic performance was achieved for a 3% Eu doped crystal with an energy resolution of 2.93% FWHM at 662keV. Simulations of SrI{sub 2}(Eu) crystals were also performed to better understand the light transport physics in scintillators and are reported. This study has important implications for the development of SrI{sub 2}(Eu) detectors for national security purposes.

  4. Improvement of an X-ray imaging detector based on a scintillating guides screen

    CERN Document Server

    Badel, X; Linnros, J; Kleimann, P; Froejdh, C; Petersson, C S

    2002-01-01

    An X-ray imaging detector has been developed for dental applications. The principle of this detector is based on application of a silicon charge coupled device covered by a scintillating wave-guide screen. Previous studies of such a detector showed promising results concerning the spatial resolution but low performance in terms of signal to noise ratio (SNR) and sensitivity. Recent results confirm the wave-guiding properties of the matrix and show improvement of the detector in terms of response uniformity, sensitivity and SNR. The present study is focussed on the fabrication of the scintillating screen where the principal idea is to fill a matrix of Si pores with a CsI scintillator. The photoluminescence technique was used to prove the wave-guiding property of the matrix and to inspect the filling uniformity of the pores. The final detector was characterized by X-ray evaluation in terms of spatial resolution, light output and SNR. A sensor with a spatial resolution of 9 LP/mm and a SNR over 50 has been achie...

  5. Developing LAr Scintillation Light Collection Ideas in the Short Baseline Neutrino Detector

    Energy Technology Data Exchange (ETDEWEB)

    Szelc, A. M. [Manchester U.

    2016-02-08

    Scintillation light is becoming the most rapidly developing feature of Liquid Argon Time Projection Chamber (LArTPC) neutrino detectors due to its capability to enhance and expand their physics reach traditionally based on charge readout. The SBND detector, set to be built on the Booster Neutrino Beam Line at Fermilab, is in a unique position to test novel liquid argon scintillation light readout systems in a detector with physics neutrino events. The different ideas under consideration by the collaboration are described, including an array of PMTs detecting direct light, SiPM coupled lightguide bars and a setup which uses PMTs/SiPMS and wavelength shifter covered reflector foils, as well as their respective strengths and physics foci and the benchmarks used to compare them.

  6. Mass Composition Sensitivity of an Array of Water Cherenkov and Scintillation Detectors

    CERN Document Server

    Gonzalez, Javier G; Roth, Markus

    2011-01-01

    We consider a hybrid array composed of scintillation and water Cherenkov detectors designed to measure the cosmic ray primary mass composition at energies of about 1 EeV. We have developed a simulation and reconstruction chain to study the theoretical performance of such an array. In this work we investigate the sensitivity of mass composition observables in relation to the geometry of the array. The detectors are arranged in a triangular grid with fixed 750 m spacing and the configuration of the scintillator detectors is optimized for mass composition sensitivity. We show that the performance for composition determination can be compared favorably to that of Xmax measurements after the difference in duty cycles is considered.

  7. A compact gamma-ray detector using wavelength-shifting fibers coupled to YAP scintillation crystal

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    The performance of a compact position sensitive gamma-ray detector based on wavelength-shifting fibers coupled to YAlO3:Ce scintillation crystal was evaluated using a Monte-Carlo simulation method.The simulation model has been setup using the GEANT4 codes.Compared with the gamma-ray detector based on the YAlO3:Ce scintillation crystal coupled to Hamamastu R2486 position sensitive photomultiplier tube.the results indicate that the gamma-ray detector based on wavelength-shifting fibers readout has good position linearity,good spatial resolution and larger effective field of view.The image and point spread function of measured point were presented.The spatial resolution reaponse as a function of position was obtained.The factors influencing spatial resolution and position linearity were discussed.

  8. A New Columnar CsI(Tl) Scintillator for iQID detectors.

    Science.gov (United States)

    Han, Ling; Miller, Brian W; Barber, H Bradford; Nagarkar, Vivek V; Furenlid, Lars R

    2014-09-12

    A 1650 μm thick columnar CsI(Tl) scintillator for upgrading iQID detectors, which is a high-resolution photon-counting gamma-ray and x-ray detector recently developed at the Center for Gamma-Ray Imaging (CGRI), has been studied in terms of sensitivity, spatial resolution and depth-of-interaction effects. To facilitate these studies, a new frame-parsing algorithm for processing raw event data is also proposed that has more degrees of freedom in data processing and can discriminate against a special kind of noise present in some low-cost intensifiers. The results show that in comparison with a 450 μm-thickness columnar CsI(Tl) scintillator, the 1650 μm thick CsI(Tl) scintillator provides more than twice the sensitivity at the expense of some spatial resolution degradation. The depth-of-interaction study also shows that event size and amplitude vary with scintillator thickness, which can assist in future detector simulations and 3D-interaction-position estimation.

  9. Sapphire scintillation tests for cryogenic detectors in the Edelweiss dark matter search

    Energy Technology Data Exchange (ETDEWEB)

    Luca, M

    2007-07-15

    Identifying the matter in the universe is one of the main challenges of modern cosmology and astrophysics. An important part of this matter seems to be made of non-baryonic particles. Edelweiss is a direct dark matter search using cryogenic germanium bolometers in order to look for particles that interact very weakly with the ordinary matter, generically known as WIMPs (weakly interacting massive particles). An important challenge for Edelweiss is the radioactive background and one of the ways to identify it is to use a larger variety of target crystals. Sapphire is a light target which can be complementary to the germanium crystals already in use. Spectroscopic characterization studies have been performed using different sapphire samples in order to find the optimum doping concentration for good low temperature scintillation. Ti doped crystals with weak Ti concentrations have been used for systematic X ray excitation tests both at room temperature and down to 30 K. The tests have shown that the best Ti concentration for optimum room temperature scintillation is 100 ppm and 50 ppm at T = 45 K. All concentrations have been checked by optical absorption and fluorescence. After having shown that sapphire had interesting characteristics for building heat-scintillation detectors, we have tested if using a sapphire detector was feasible within a dark matter search. During the first commissioning tests of Edelweiss-II, we have proved the compatibility between a sapphire heat scintillation detector and the experimental setup. (author)

  10. Improved Growth Methods for LaBr3 Scintillation Radiation Detectors

    Energy Technology Data Exchange (ETDEWEB)

    McGregor, Douglas S

    2011-05-01

    The objective is to develop advanced materials for deployment as high-resolution gamma ray detectors. Both LaBr3 and CeBr3 are advanced scintillation materials, and will be studied in this research. Prototype devices, in collaboration Sandia National Laboratories, will be demonstrated along with recommendations for mass production and deployment. It is anticipated that improved methods of crystal growth will yield larger single crystals of LaBr3 for deployable room-temperature operated gamma radiation spectrometers. The growth methods will be characterized. The LaBr3 and CeBr3 scintillation crystals will be characterized for light yield, spectral resolution, and for hardness.

  11. A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators

    CERN Document Server

    Kamińska, D; Czerwiński, E; Alfs, D; Bednarski, T; Białas, P; Curceanu, C; Dulski, K; Głowacz, B; Gupta-Sharma, N; Gorgol, M; Hiesmayr, B C; Jasińska, B; Korcyl, G; Kowalski, P; Krzemień, W; Krawczyk, N; Kubicz, E; Mohammed, M; Niedźwiecki, Sz; Pawlik-Niedźwiecka, M; Raczyński, L; Rudy, Z; Silarski, M; Wieczorek, A; Wiślicki, W; Zgardzińska, B; Zieliński, M; Moskal, P

    2016-01-01

    We present a study of the application of the Jagiellonian Positron Emission Tomograph (J-PET) for the registration of gamma quanta from decays of ortho-positronium (o-Ps). The J-PET is the first positron emission tomography scanner based on organic scintillators in contrast to all current PET scanners based on inorganic crystals. Monte Carlo simulations show that the J-PET as an axially symmetric and high acceptance scanner can be used as a multi-purpose detector well suited to pursue research including e.g. tests of discrete symmetries in decays of ortho-positronium in addition to the medical imaging. The gamma quanta originating from o-Ps decay interact in the plastic scintillators predominantly via the Compton effect, making the direct measurement of their energy impossible. Nevertheless, it is shown in this paper that the J-PET scanner will enable studies of the o-Ps$\\to3\\gamma$ decays with angular and energy resolution equal to $\\sigma(\\theta) \\approx 0.4^{\\circ}$ and $\\sigma(E) \\approx 4.1$ keV, respect...

  12. Calibration of a plastic detector PVT of large dimensions for the detection gamma radiation; Calibracion de un detector plastico de PVT de grandes dimensiones para la deteccion de radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Armenteros Carmona, J. C.; Suarez navarro, M. J.; Gonzalez-gonzalez, J. A.; Pujol, L.

    2011-07-01

    This article describes the development work on the porch RadSentry Canberra brand that uses 2 plastic scintillation detectors PVT large (172 x 32 x 4 cm). In this paper we present the different calibration necessary for the proper functioning of equipment: channel-energy calibration, energy resolution, and efficiency-energy.

  13. Hybrid metal organic scintillator materials system and particle detector

    Science.gov (United States)

    Bauer, Christina A.; Allendorf, Mark D.; Doty, F. Patrick; Simmons, Blake A.

    2011-07-26

    We describe the preparation and characterization of two zinc hybrid luminescent structures based on the flexible and emissive linker molecule, trans-(4-R,4'-R') stilbene, where R and R' are mono- or poly-coordinating groups, which retain their luminescence within these solid materials. For example, reaction of trans-4,4'-stilbenedicarboxylic acid and zinc nitrate in the solvent dimethylformamide (DMF) yielded a dense 2-D network featuring zinc in both octahedral and tetrahedral coordination environments connected by trans-stilbene links. Similar reaction in diethylformamide (DEF) at higher temperatures resulted in a porous, 3-D framework structure consisting of two interpenetrating cubic lattices, each featuring basic to zinc carboxylate vertices joined by trans-stilbene, analogous to the isoreticular MOF (IRMOF) series. We demonstrate that the optical properties of both embodiments correlate directly with the local ligand environments observed in the crystal structures. We further demonstrate that these materials produce high luminescent response to proton radiation and high radiation tolerance relative to prior scintillators. These features can be used to create sophisticated scintillating detection sensors.

  14. Detector block based on arrays of 144 SiPMs and monolithic scintillators: A performance study

    Energy Technology Data Exchange (ETDEWEB)

    González, A.J.; Conde, P.; Iborra, A. [Institute for Instrumentation in Molecular Imaging (I3M), Universidad Politécnica de Valencia – CSIC – CIEMAT (Spain); Aguilar, A. [Communications and Digital Systems Design Group (DSDC), Universidad de Valencia (Spain); Bellido, P. [Institute for Instrumentation in Molecular Imaging (I3M), Universidad Politécnica de Valencia – CSIC – CIEMAT (Spain); García-Olcina, R. [Communications and Digital Systems Design Group (DSDC), Universidad de Valencia (Spain); Hernández, L.; Moliner, L.; Rigla, J.P.; Rodríguez-Álvarez, M.J.; Sánchez, F.; Seimetz, M.; Soriano, A. [Institute for Instrumentation in Molecular Imaging (I3M), Universidad Politécnica de Valencia – CSIC – CIEMAT (Spain); Torres, J. [Communications and Digital Systems Design Group (DSDC), Universidad de Valencia (Spain); Vidal, L.F.; Benlloch, J.M. [Institute for Instrumentation in Molecular Imaging (I3M), Universidad Politécnica de Valencia – CSIC – CIEMAT (Spain)

    2015-07-01

    We have developed a detector block composed by a monolithic LYSO scintillator coupled to a custom made 12×12 SiPMs array. The design is mainly focused to applications such as Positron Emission Tomography. The readout electronics is based on 3 identical and scalable Application Specific Integrated Circuits (ASIC). We have determined the main performance of the detector block namely spatial, energy, and time resolution but also the system capability to determine the photon depth of interaction, for different crystal surface treatments. Intrinsic detector spatial resolution values as good as 1.7 mm FWHM and energies of 15% for black painted crystals were measured.

  15. Spallation products induced by energetic neutrons in plastic detector material

    CERN Document Server

    Grabisch, K; Enge, W; Scherzer, R

    1977-01-01

    Cellulose nitrate plastic detector sheets were irradiated with secondary neutrons of the 22 GeV/c proton beam at the CERN accelerator. He, Li and Be particles which are produced in nuclear interactions of the neutrons with the target elements C, N and O of the plastic detector material are measured. Preliminary angle and range distributions and isotropic abundances of the secondary particles are discussed. (6 refs).

  16. Automated response matching for organic scintillation detector arrays

    Science.gov (United States)

    Aspinall, M. D.; Joyce, M. J.; Cave, F. D.; Plenteda, R.; Tomanin, A.

    2017-07-01

    This paper identifies a digitizer technology with unique features that facilitates feedback control for the realization of a software-based technique for automatically calibrating detector responses. Three such auto-calibration techniques have been developed and are described along with an explanation of the main configuration settings and potential pitfalls. Automating this process increases repeatability, simplifies user operation, enables remote and periodic system calibration where consistency across detectors' responses are critical.

  17. The PRESHOWER - a New Multichnnel Detector for the CDF. The Scintillator Plates of the New Detector: Design, Production, Quality Control

    CERN Document Server

    Artikov, A M; Chocheli, D; Danilov, V; Grinyov, B; Lebedev, V; Senchyshyn, V G

    2005-01-01

    To increase the CDF efficiency when studying heavy quark processes there was designed, constructed and put into operation a new multichannel detector --- the so called Central Preshower. It was positioned before the central electromagnetic calorimeter and increased the photon, lepton and hadron identification efficiency. JINR in cooperation with the Institute of Scintillating Materials (Kharkiv) has created a sensitive element of the new detector: about 2800 units of the scintillation tiles; the specially developed quality control procedure guaranteed the necessary high light yield for tiles mass production. The chosen tiles were equipped at FNAL by two loops (about 1 m long) of WLS fibers positioned inside the $\\Omega $-shape groove; it guaranteed a light yield of $\\sim$ 25--35 photoelectrons/MIP.

  18. Study on the Characteristics of a Scintillator for Beta-ray Detection using Epoxy Resin

    Science.gov (United States)

    Nam, Jong Soo; Choi, Yong Seok; Hong, Sang Bum; Seo, Bum Kyung; Moon, Jei Kwon; Choi, Jong Won

    2017-09-01

    A thin plate of a plastic scintillator for detecting a beta-ray was developed. The plastic scintillator was made using epoxy resin and organic scintillators such as 2.5-diphenyloxazole (PPO) and 1,4-bis [5-phenyl-2-oxazole] benzene (POPOP). The mixture ratio of epoxy resin and the organic scintillators was determined using their absorbance, transmittance, emission spectra, and transparency. Their optimal weight percentage of PPO and POPOP in the organic scintillators was adjusted to 0.2 wt%:0.01 wt%. The prepared plastic scintillator was used to measure the standard source of Sr-90. The pulse height spectra and total counts of the prepared plastic scintillator were similar to a commercial plastic scintillator. Based on the above results, a large-area plastic scintillator was prepared for rapid investigation of a site contaminated with Sr-90. The prepared large-area plastic scintillator was evaluated for the characteristics in the laboratory. The evaluation results are expected to be usefully utilized in the development of a large-area plastic scintillation detector. The large-area plastic scintillation detector developed on the basis of the evaluation results is expected to be utilized to quickly measure the contamination of Sr-90 in the grounds used as a nuclear power facility.

  19. Fast Neutron Detector for Fusion Reactor KSTAR Using Stilbene Scintillator

    CERN Document Server

    Lee, Seung Kyu; Kim, Gi-Dong; Kim, Yong-Kyun

    2011-01-01

    Various neutron diagnostic tools are used in fusion reactors to evaluate different aspects of plasma performance, such as fusion power, power density, ion temperature, fast ion energy, and their spatial distributions. The stilbene scintillator has been proposed for use as a neutron diagnostic system to measure the characteristics of neutrons from the Korea Superconducting Tokamak Advanced Research (KSTAR) fusion reactor. Specially designed electronics are necessary to measure fast neutron spectra with high radiation from a gamma-ray background. The signals from neutrons and gamma-rays are discriminated by the digital charge pulse shape discrimination (PSD) method, which uses total to partial charge ratio analysis. The signals are digitized by a flash analog-to-digital convertor (FADC). To evaluate the performance of the fabricated stilbene neutron diagnostic system, the efficiency of 10 mm soft-iron magnetic shielding and the detection efficiency of fast neutrons were tested experimentally using a 252Cf neutr...

  20. Non-Carbon Dyes For Platic Scintillators- Report

    Energy Technology Data Exchange (ETDEWEB)

    Teprovich, J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Colon-Mercado, H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Gaillard, J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Sexton, L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Washington, A. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Ward, P. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Velten, J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-10-19

    Scintillation based detectors are desirable for many radiation detection applications (portal and border monitoring, safeguards verification, contamination detection and monitoring). The development of next generation scintillators will require improved detection sensitivity for weak gamma ray sources, and fast and thermal neutron quantification. Radiation detection of gamma and neutron sources can be accomplished with organic scintillators, however, the single crystals are difficult to grow for large area detectors and subject to cracking. Alternatives to single crystal organic scintillators are plastic scintillators (PS) which offer the ability to be shaped and scaled up to produce large sized detectors. PS is also more robust than the typical organic scintillator and are ideally suited for deployment in harsh real-world environments. PS contain a mixture of dyes to down-convert incident radiation into visible light that can be detected by a PMT. This project will evaluate the potential use of nano-carbon dyes in plastic scintillators.

  1. Prompt directional detection of galactic supernova by combining large liquid scintillator neutrino detectors

    CERN Document Server

    Fischer, V; Lasserre, T; Volpe, C; Cribier, M; Durero, M; Gaffiot, J; Houdy, T; Letourneau, A; Mention, G; Pequignot, M; Sibille, V; Vivier, M

    2015-01-01

    Core-collapse supernovae produce an intense burst of electron antineutrinos in the few-tens-of-MeV range. Several Large Liquid Scintillator-based Detectors (LLSD) are currently operated worldwide, being very effective for low energy antineutrino detection through the Inverse Beta Decay (IBD) process. In this article, we develop a procedure for the prompt extraction of the supernova location by revisiting the details of IBD kinematics over the broad energy range of supernova neutrinos. Combining all current scintillator-based detector, we show that one can locate a canonical supernova at 10 kpc with an accuracy of 45 degrees (68% C.L.). After the addition of the next generation of scintillator-based detectors, the accuracy could reach 12 degrees (68% C.L.), therefore reaching the performances of the large water Cerenkov neutrino detectors. We also discuss a possible improvement of the SuperNova Early Warning System (SNEWS) inter-experiment network with the implementation of a directionality information in each...

  2. Neutron/gamma pulse shape discrimination in plastic scintillators: Preparation and characterization of various compositions

    Energy Technology Data Exchange (ETDEWEB)

    Blanc, Pauline [CEA, LIST, Laboratoire Capteurs et Architectures Électroniques, F-91191 Gif-sur-Yvette (France); Laboratoire de Photophysique et Photochimie Supramoléculaires et Macromoléculaires (CNRS UMR 8531), École Normale Supérieure de Cachan, 61 Avenue du Président Wilson, F-94235 Cachan cedex (France); Hamel, Matthieu, E-mail: matthieu.hamel@cea.fr [CEA, LIST, Laboratoire Capteurs et Architectures Électroniques, F-91191 Gif-sur-Yvette (France); Dehé-Pittance, Chrystèle; Rocha, Licinio [CEA, LIST, Laboratoire Capteurs et Architectures Électroniques, F-91191 Gif-sur-Yvette (France); Pansu, Robert B. [Laboratoire de Photophysique et Photochimie Supramoléculaires et Macromoléculaires (CNRS UMR 8531), École Normale Supérieure de Cachan, 61 Avenue du Président Wilson, F-94235 Cachan cedex (France); Normand, Stéphane [CEA, LIST, Laboratoire Capteurs et Architectures Électroniques, F-91191 Gif-sur-Yvette (France)

    2014-06-01

    This work deals with the preparation and evaluation of plastic scintillators for neutron/gamma pulse shape discrimination (PSD). We succeeded in developing a plastic scintillator with good neutron/gamma discrimination properties in the range of what is already being commercialized. Several combinations of primary and secondary fluorophores were implemented in chemically modified polymers. These scintillators were fully characterized by fluorescence spectroscopy and under neutron irradiation. The materials proved to be stable for up to 5 years without any degradation of PSD properties. They were then classified in terms of their PSD capabilities and light yield. Our best candidate, 28.6 wt% of primary fluorophore with a small amount of secondary fluorophore, shows promising PSD results and is particularly suited to industrial development, because its preparation does not involve the use of expensive or exotic compounds. Furthermore, even at the highest prepared concentration, high stability over time was observed. As a proof of concept, one sample with dimensions 109 mm ∅×114 mm height (≈1 L) was prepared.

  3. In-situ calibration of a PMT inside a scintillation detector by means of primary scintillation detection

    CERN Document Server

    Álvarez, V; Cárcel, S; Castel, J; Cebrián, S; Cervera, A; Conde, C A N; Dafni, T; Dias, T H V T; Díaz, J; Egorov, M; Esteve, R; Evtoukhovitch, P; Fernandes, L M P; Ferrario, P; Ferreira, A L; Freitas, E D C; Gehman, V M; Gil, A; Goldschmidt, A; Gómez, H; Gómez-Cadenas, J J; González-Díaz, D; Gutiérrez, R M; Hauptman, J; Morata, J A Hernando; Herrera, D C; Iguaz, F J; Irastorza, I G; Jinete, M A; Labarga, L; Laing, A; Liubarsky, I; Lopes, J A M; Lorca, D; Losada, M; Luzón, G; Marí, A; Martín-Albo, J; Martínez, A; Miller, T; Moiseenko, A; Monrabal, F; Monteiro, C M B; Mora, F J; Moutinho, L M; Vidal, J Muñoz; da Luz, H Natal; Navarro, G; Nebot, M; Nygren, D; Oliveira, C A B; Palma, R; Pérez, J; Aparicio, J L Pérez; Renner, J; Ripoll, L; Rodríguez, A; Rodríguez, J; Santos, F P; Santos, J M F dos; Segui, L; Serra, L; Shuman, D; Simón, A; Sofka, C; Sorel, M; Toledo, J F; Tomás, A; Torrent, J; Tsamalaidze, Z; Vázquez, D; Veloso, J F C A; Villar, J A; Webb, R C; White, J T; Yahlali, N

    2012-01-01

    We have investigated the possibility of calibrating the PMTs of scintillation detectors, using the primary scintillation produced by X-rays to induce single photoelectron response of the PMT. The high-energy tail of this response, can be approximated to an exponential function, under some conditions. In these cases, it is possible to determine the average gain for each PMT biasing voltage from the inverse of the exponent of the exponential fit to the tail, which can be done even if the background and/or noise cover-up most of the distribution. We have compared our results with those obtained by the commonly used single electron response (SER) method, which uses a LED to induce a single photoelectron response of the PMT and determines the peak position of such response, relative to the pedestal peak (the electronic noise peak, which corresponds to 0 photoelectrons). The results of the exponential fit method agree with those obtained by the SER method when the average number of photoelectrons reaching the first...

  4. Discriminating cosmic muons and radioactivity using a liquid scintillation fiber detector

    Science.gov (United States)

    Zhang, Y. P.; Xu, J. L.; Lu, H. Q.; Zhang, P.; Zhang, C. C.; Yang, C. G.

    2017-03-01

    In the case of underground experiments for neutrino physics or rare event searches, the background caused by cosmic muons contributes significantly and therefore must be identified and rejected. We proposed and optimized a new detector using liquid scintillator with wavelenghth-shifting fibers which can be employed as a veto detector for cosmic muons background rejection. From the prototype study, it has been found that the detector has good performances and is capable of discriminating between muons induced signals and environmental radiation background. Its muons detection efficiency is greater than 98%, and on average, 58 photo-electrons (p.e.) are collected when a muon passes through the detector. To optimize the design and enhance the collection of light, the reflectivity of the coating materials has been studied in detail. A Monte Carlo simulation of the detector has been developed and compared to the performed measurements showing a good agreement between data and simulation results.

  5. Characterization of liquid scintillation detector (BC-501A) and digital pulse shape discrimination (DPSD) system

    Energy Technology Data Exchange (ETDEWEB)

    Lombigit, L., E-mail: lojius@nm.gov.my; Yussup, N., E-mail: nolida@nm.gov.my; Ibrahim, Maslina Mohd; Rahman, Nur Aira Abd; Rawi, M. Z. M. [Instrumentation Group, Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor (Malaysia)

    2015-04-29

    A digital n/γ pulse shape discrimination (PSD) system is currently under development at Instrumentation and Automation Centre, Malaysian Nuclear Agency. This system aims at simultaneous detection of fast neutron and gamma ray in mixed radiations environment. This work reports the system characterization performed on the liquid scintillation detector (BC-501A) and digital pulse shape discrimination (DPSD) system. The characterization involves measurement of electron light output from the BC-501A detector and energy channels calibration of the pulse height spectra acquired with DPSD system using set of photon reference sources. The main goal of this experiment is to calibrate the ADC channel of our DPSD system, characterized the BC-501 detector and find the position of Compton edge which later could be used as threshold for the n/γ PSD experiment. The detector resolution however is worse as compared to other published data but it is expected as our detector has a smaller active volume.

  6. Development and Characterization of 6Li-doped Liquid Scintillator Detectors for PROSPECT

    Science.gov (United States)

    Gaison, Jeremy; Prospect Collaboration

    2016-09-01

    PROSPECT, the Precision Reactor Oscillation and Spectrum experiment, is a phased reactor antineutrino experiment designed to search for eV-scale sterile neutrinos via short-baseline neutrino oscillations and to make a precision measurement of the 235U reactor antineutrino spectrum. A multi-ton, optically segmented detector will be deployed at Oak Ridge National Laboratory's (ORNL) High Flux Isotope Reactor (HFIR) to measure the reactor spectrum at baselines ranging from 7-12m. A two-segment detector prototype with 50 liters of active liquid scintillator target has been built to verify the detector design and to benchmark its performance. In this presentation, we will summarize the performance of this detector prototype and describe the optical and energy calibration of the segmented PROSPECT detectors.

  7. Design and development of hard x-ray imaging detector using scintillator and Si photomultiplier

    Science.gov (United States)

    Goyal, S. K.; Naik, Amisha P.; Mithun, N. P. S.; Vadawale, S. V.; Acharya, Y. B.; Patel, A. R.; Ladiya, T.; Devashrayee, Niranjan M.

    2016-07-01

    There are various astrophysical phenomena which are of great importance and interest such as stellar explosions, Gamma ray bursts etc. There is also a growing interest in exploring the celestial sources in hard X-rays. High sensitive instruments are essential to perform the detailed studies of these cosmic accelerators and explosions. Hard X-ray imaging detectors having high absorption efficiency and mm spatial resolution are the key requirements to locate the generation of these astrophysical phenomenon. We hereby present a detector module which consists of a single CsI scintillation detector of size 15 x 15 x 3 mm3. The photon readout is done using an array of Silicon Photomultipliers (SiPMs). SiPM is a new development in the field of photon detection and can be described as 2D array of small (hundreds of μm2) avalanche photodiodes. We have achieved a spatial resolution of 0.5 mm with our initial setup. By using the array of these detector modules, we can build the detector with a large sensitive area with a very high spatial resolution. This paper presents the experimental details for single detector module using CsI (Tl) scintillator and SiPM and also presents the preliminary results of energy and position measurement. The GEANT4 simulation has also been carried out for the same geometry.

  8. Time Resolution and Linearity Measurements for a Scintillating Fiber Detector Instrumented with VLPC's

    CERN Document Server

    Bross, A D; Costa, J; Johnson, M; Moreira, L; Thompson, J; Bross, Alan; Chaves, Ana Lucia; Costa, Jesse; Johnson, Marvin; Moreira, Lourival; Thompson, Joey

    1997-01-01

    The time resolution for a charged particle detection is reported for a typical scintillating fiber detector instrumented with Rockwell HISTE-IV Visible Light Photon Counters. The resolution measurements are shown to agree with a simple Monte Carlo model, and the model is used to make recomendations for improved performance. In addition, the gain linearity of a sample of VLPC devices was measured. The gain is shown to be linear for incident light intensities which produce up to approximately 600 photoelectrons per event.

  9. Algorithms of Coordinates Scintillations Calculation in the Gamma-Camera Detector

    Directory of Open Access Journals (Sweden)

    G.A. Polyakov

    2010-01-01

    Full Text Available The methods and algorithms of scintillation coordinates calculation in gamma-camera position-sensitive detector are considered in the paper. The results of numerical model experiments, which were carried out for clearing-up of relative operating speed of different coordinate calculation methods, are presented. The analysis of obtained results was carried out for determination of perspective for application algorithms and likelihood methods.

  10. A gas scintillation counter with imaging optics and large area UV-detector

    Energy Technology Data Exchange (ETDEWEB)

    Nickles, J. E-mail: nickles@hsb.uni-frankfurt.de; Braeuning, H.; Braeuning-Demian, A.; Dangendorf, V.; Breskin, A.; Chechik, R.; Rauschnabel, K.; Schmidt-Boecking, H

    2002-01-21

    We report on the improvements in the position sensitive readout of a xenon-filled gas scintillation proportional counter. Using an imaging optic for UV-light in the region of 170 nm, the position resolution could be improved by more than 30%. In addition, we have obtained first encouraging results for the use of the recently developed gas electron multiplier together with a CsI-photocathode as a large area UV-detector system.

  11. A gas scintillation counter with imaging optics and large area UV-detector

    CERN Document Server

    Nickles, J; Bräuning-Demian, A; Breskin, Amos; Chechik, R; Dangendorf, V; Rauschnabel, K; Schmidt-Böcking, H

    2002-01-01

    We report on the improvements in the position sensitive readout of a xenon-filled gas scintillation proportional counter. Using an imaging optic for UV-light in the region of 170 nm, the position resolution could be improved by more than 30%. In addition, we have obtained first encouraging results for the use of the recently developed gas electron multiplier together with a CsI-photocathode as a large area UV-detector system.

  12. Pulse shape discrimination in helium-4 scintillation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Kelley, Ryan P., E-mail: rpkelley@ufl.edu; Enqvist, Andreas; Jordan, Kelly A.

    2016-09-11

    Three algorithms were investigated for discriminating between neutrons and gamma rays in a pressurized {sup 4}He gas fast neutron detector: charge comparison, weighted integration, and neutron-gamma model analysis (NGMA). For each algorithm, a comprehensive pulse shape discrimination study was conducted using time-of-flight measurements, receiver operator characteristic curves, figure of merit performance measures, and a comparison of performance between {sup 252}Cf and PuBe mixed neutron/gamma sources. The NGMA method was found to have the best overall performance by both the figure of merit and the receiver operator characteristic curve. The results also illustrated the high gamma rejection efficiency of these detectors, which is desirable in a variety of neutron monitoring applications.

  13. Modelling of scintillator based flat-panel detectors with Monte-Carlo simulations

    Science.gov (United States)

    Reims, N.; Sukowski, F.; Uhlmann, N.

    2011-01-01

    Scintillator based flat panel detectors are state of the art in the field of industrial X-ray imaging applications. Choosing the proper system and setup parameters for the vast range of different applications can be a time consuming task, especially when developing new detector systems. Since the system behaviour cannot always be foreseen easily, Monte-Carlo (MC) simulations are keys to gain further knowledge of system components and their behaviour for different imaging conditions. In this work we used two Monte-Carlo based models to examine an indirect converting flat panel detector, specifically the Hamamatsu C9312SK. We focused on the signal generation in the scintillation layer and its influence on the spatial resolution of the whole system. The models differ significantly in their level of complexity. The first model gives a global description of the detector based on different parameters characterizing the spatial resolution. With relatively small effort a simulation model can be developed which equates the real detector regarding signal transfer. The second model allows a more detailed insight of the system. It is based on the well established cascade theory, i.e. describing the detector as a cascade of elemental gain and scattering stages, which represent the built in components and their signal transfer behaviour. In comparison to the first model the influence of single components especially the important light spread behaviour in the scintillator can be analysed in a more differentiated way. Although the implementation of the second model is more time consuming both models have in common that a relatively small amount of system manufacturer parameters are needed. The results of both models were in good agreement with the measured parameters of the real system.

  14. Occulting Light Concentrators in Liquid Scintillator Neutrino Detectors

    Science.gov (United States)

    Buizza Avanzini, Margherita; Cabrera, Anatael; Dusini, Stefano; Grassi, Marco; He, Miao; Wu, Wenjie

    2017-09-01

    The experimental efforts characterizing the era of precision neutrino physics revolve around collecting high-statistics neutrino samples and attaining an excellent energy and position resolution. Next generation liquid-based neutrino detectors, such as JUNO, HyperKamiokande, etc, share the use of a large target mass, and the need of pushing light collection to the edge for maximal calorimetric information. Achieving high light collection implies considerable costs, especially when considering detector masses of several kt. A traditional strategy to maximize the effective photo-coverage with the minimum number of PMTs relies on Light Concentrators (LC), such as Winston Cones. In this paper, the authors introduce a novel concept called Occulting Light Concentrators (OLC), whereby a traditional LC gets tailored to a conventional PMT, by taking into account its single-photoelectron collection efficiency profile and thus occulting the worst performing portion of the photocathode. Thus, the OLC shape optimization takes into account not only the optical interface of the PMT, but also the maximization of the PMT detection performances. The light collection uniformity across the detector is another advantage of the OLC system. By considering the case of JUNO, we will show OLC capabilities in terms of light collection and energy resolution.

  15. Characterization of a scintillating fibers read by MPPC detectors trigger prototype for the AMADEUS experiment

    Science.gov (United States)

    Bazzi, M.; Berucci, C.; Curceanu, C.; D'Uffizi, A.; Piscicchia, K.; Poli Lener, M.; Romero Vidal, A.; Sbardella, E.; Scordo, A.; Vazquez Doce, O.

    2013-05-01

    Multi-Pixel Photon Counters (MPPC) consist of hundreds of micro silicon Avalanche PhotoDiodes (APD) working in Geiger mode. The high gain and the low noise, typical of these devices, together with their good performance in magnetic field, make them ideal readout detectors for scintillating fibers as trigger detectors in particle and nuclear physics experiments like AMADEUS, where such detectors are planned to be used to trigger on charged kaon pairs. In order to investigate the detection efficiency of such a system, a prototype setup consisting of 32, 1 mm diameter scintillating fibers, arranged in two double layers of 16 fibers each, and read out at both sides by 64 MPPCs with an ad-hoc built readout electronics, was tested at the πM-1 line of the Paul Scherrer Institute (PSI) in Villigen, Switzerland. The detection efficiency and the trigger capability were measured on a beam containing protons, electrons, muons and pions with a momentum of 440 MeV/c. The measured average efficiency for protons for a double layer of scintillating fibers (96.2±1.0%) represents a guarantee of the good performance of this system as a trigger for the AMADEUS experiment.

  16. Enhanced light extraction efficiency of plastic scintillator by photonic crystal prepared with a self-assembly method

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jinliang [State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Radiation Detection Research Center, Northwest Institute of Nuclear Technology, Xi’an, 710024 (China); Zhu, Zhichao [Shanghai Key Laboratory of Special Artificial Microstructure Materials and Technology, School of Physics Science and Engineering, Tongji University, Shanghai 200092 (China); Chen, Liang; Ouyang, Xiaoping [State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Radiation Detection Research Center, Northwest Institute of Nuclear Technology, Xi’an, 710024 (China); Liu, Bo, E-mail: lbo@tongji.edu.cn [Shanghai Key Laboratory of Special Artificial Microstructure Materials and Technology, School of Physics Science and Engineering, Tongji University, Shanghai 200092 (China); Cheng, Chuanwei [Shanghai Key Laboratory of Special Artificial Microstructure Materials and Technology, School of Physics Science and Engineering, Tongji University, Shanghai 200092 (China); Hu, Jing; He, Shiyi [State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Radiation Detection Research Center, Northwest Institute of Nuclear Technology, Xi’an, 710024 (China); Wang, Zewei [State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Radiation Detection Research Center, Northwest Institute of Nuclear Technology, Xi’an, 710024 (China); College of Materials Science and Engineering, Xiangtan University, Xiangtan 411105 (China); Gu, Mu; Chen, Hong [Shanghai Key Laboratory of Special Artificial Microstructure Materials and Technology, School of Physics Science and Engineering, Tongji University, Shanghai 200092 (China)

    2015-09-21

    Plastic scintillators are extensively used in various radiation measurement systems. However the total internal reflection decreases the scintillation light output, leading to a low detection efficiency especially in these weak signal detection situations. In the present investigation, we have designed a light extraction scheme based on the photonic crystal formed with a monolayer periodic array of polystyrene nanospheres by a self-assembly method. The photonic crystal coated on the surface of plastic scintillator can significantly enhance the light extraction by 120% compared with the plain reference sample under X-ray excitation, which is achieved by the principle of the coupling of evanescent field near the scintillator-air interface with the photonic crystal.

  17. LHCb Scintillating Fiber detector front end electronics design and quality assurance

    Science.gov (United States)

    Vink, W. E. W.; Pellegrino, A.; Ietswaard, G. C. M.; Verkooijen, J. C.; Carneiro, U.; Massefferi, A.

    2017-03-01

    The on-detector electronics of the LHCb Scintillating Fiber Detector consists of multiple PCBs assembled in a unit called Read Out Box, capable of reading out 2048 channels with an output rate of 70 Gbps. There are three types of boards: PACIFIC, Clusterization and Master Board. The Pacific Boards host PACIFIC ASICs, with pre-amplifier and comparator stages producing two bits of data per channel. A cluster-finding algorithm is then run in an FPGA on the Clusterization Board. The Master Board distributes fast and slow control, and power. We describe the design, production and test of prototype PCBs.

  18. Determination of the time resolution for neutron scintillation detectors by multi-coincidence measurement

    Institute of Scientific and Technical Information of China (English)

    LI Yong-Ming; RUAN Xi-Chao; ZHOU Sin; MA Zhong-Yuan

    2011-01-01

    Based on the multi-coincidence measurement, the time resolution of three liquid scintillation detectors (BC501A) were determined strictly by solving the coincidence equations, where the influence from electronics estimated by self coincidence measurement as well as the background had been considered. The result of this work agreed well with the result that was deduced from the traditional method, and it will be helpful to analyze the energy resolution of neutron time of flight spectra measured by using such detectors at CIAE (China Institute of Atomic Energy).

  19. R&D on scintillation materials for novel ionizing radiation detectors for High Energy Physics, medical imaging and industrial applications

    CERN Multimedia

    Chipaux, R; Vasilev, A; Rinaldi, D; Morel, C; Choi, Y

    2002-01-01

    The Crystal Clear Collaboration (CCC) was approved by the Detector R&D Committee as RD18 in 1990 with the objective of developing new inorganic scintillators suitable for crystal electromagnetic calorimeters of LHC experiments. From 1990 to 1994, CCC made an intensive investigation for the quest of the most adequate ideal scintillator for the LHC; three main candidates were identified and extensively studied : CeF$_{3}$, PbWO$_{4}$ and heavy scintillating glasses. Lead tungstate was chosen by CMS and ALICE as the most cost effective crystal compliant to LHC conditions. Today 76648 PWO crystals are installed in CMS and 17920 in ALICE. After this success Crystal clear has continued its investigation on new scintillators and the understanding of scintillation mechanisms and light transfer properties in particular : The understanding of cerium ion as activator, The development of LuAP, LuYAP crystals for medical imaging applications, (CERN patent) Investigation of Ytterbium based scintillators for solar ne...

  20. Assessment of array scintillation detector for follicle thyroid 2-D image acquisition using Monte Carlo simulation

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Carlos Borges da; Santanna, Claudio Reis de [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)]. E-mails: borges@ien.gov.br; santanna@ien.gov.br; Braz, Delson [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia (COPPE). Lab. de Instrumentacao Nuclear]. E-mail: delson@lin.ufrj.br; Carvalho, Denise Pires de [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Inst. de Biofisica Carlos Chagas Filho. Lab. de Fisiologia Endocrina]. E-mail: dencarv@ufrj.br

    2007-07-01

    This work presents an innovative study to find out the adequate scintillation inorganic detector array to be used coupled to a specific light photo sensor, a charge coupled device (CCD), through a fiber optic plate. The goal is to choose the type of detector that fits a 2-dimensional imaging acquisition of a cell thyroid tissue application with high resolution and detection efficiency in order to map a follicle image using gamma radiation emission. A point or volumetric source - detector simulation by using a MCNP4B general code, considering different source energies, detector materials and geometry including pixel sizes and reflector types was performed. In this study, simulations were performed for 7 x 7 and 127 x 127 arrays using CsI(Tl) and BGO scintillation crystals with pixel size ranging from 1 x 1 cm{sup 2} to 10 x 10 {mu}m{sup 2} and radiation thickness ranging from 1 mm to 10 mm. The effect of all these parameters was investigated to find the best source-detector system that result in an image with the best contrast details. The results showed that it is possible to design a specific imaging system that allows searching for in-vitro studies, specifically in radiobiology applied to endocrine physiology. (author)

  1. Design Constraints for a WIMP Dark Matter and pp Solar Neutrino Liquid Neon Scintillation Detector

    CERN Document Server

    Boulay, M G; Lidgard, J

    2004-01-01

    Detailed Monte-Carlo simulations were used to evaluate the performance of a liquid neon scintillation detector for dark matter and low-energy solar neutrino interactions. A maximum-likelihood event vertex fitter including PMT time information was developed, which significantly improves position resolution over spatial-only algorithms, and substantially decreases the required detector size and achievable analysis energy threshold. The ultimate sensitivity to WIMP dark matter and the pp flux uncertainty are evaluated as a function of detector size. The dependence on the neon scintillation and PMT properties are evaluated. A 300 cm radius detector would allow a ~13 keV threshold, a pp flux uncertainty of ~1%, and limits on the spin-independent WIMP-nucleon cross-section of ~10^{-46} cm^2 for a 100 GeV WIMP, using commercially available PMTs. Detector response calibration and background requirements for a precision pp measurement are defined. Internal radioactivity requirements for uranium, thorium, and krypton a...

  2. Development and characterization of scintillation based detectors for the use in radiological early warning networks

    Science.gov (United States)

    Kessler, P.; Dombrowski, H.; Neumaier, S.

    2016-02-01

    To detect radiological incidents, all members of the European Union have installed nationwide radiological early warning networks. Most of the installed detector systems supply only dosimetric information. Novel spectrometry systems are considered to be good candidates for a new detector generation for environmental radiation monitoring because they will supply both nuclide-specific information and ambient dose equivalent rate values. Four different detector types were chosen and compared with each other (LaBr3, CeBr3, SrI2 scintillation detectors, and CdZnTe, a semiconductor detector). As a first step, the inherent background of these detectors was measured in the low background underground laboratory UDO II of PTB. As a second step, the relative detection sensitivity between the various detectors was determined at different energies. Finally, the detectors were exposed to a 4π-radiation field of radon progeny in PTB's radon chamber. The obtained results show that the investigated detectors are well suited for environmental radiation monitoring.

  3. Characterization of a scintillating lithium glass ultra-cold neutron detector

    Energy Technology Data Exchange (ETDEWEB)

    Jamieson, B.; Rebenitsch, L.A.; Hansen-Romu, S.; Mammei, R.; Martin, J.W. [University of Winnipeg, Department of Physics, Winnipeg (Canada); Lauss, B. [Paul Scherrer Institute, Laboratory for Particle Physics, Villigen (Switzerland); Lindner, T. [TRIUMF, Vancouver (Canada); University of Winnipeg, Department of Physics, Winnipeg (Canada); Pierre, E. [TRIUMF, Vancouver (Canada); Osaka University, Research Centre for Nuclear Physics, Osaka (Japan)

    2017-01-15

    A {sup 6}Li-glass-based scintillation detector developed for the TRIUMF neutron electric dipole moment experiment was characterized using the ultra-cold neutron source at the Paul Scherrer Institute (PSI). The data acquisition system for this detector was demonstrated to perform well at rejecting backgrounds. An estimate of the absolute efficiency of background rejection of 99.7±0.1% is made. For variable ultra-cold neutron rate (varying from < 1 kHz to approx. 100 kHz per channel) and background rate seen at the Paul Scherrer Institute, we estimate that the absolute detector efficiency is 89.7{sup +1.3}{sub -1.9}%. Finally a comparison with a commercial Cascade detector was performed for a specific setup at the West-2 beamline of the ultra-cold neutron source at PSI. (orig.)

  4. A novel fast response and radiation-resistant scintillator detector for beam loss monitor

    Science.gov (United States)

    Ji, Y.; Tang, Z.; Li, C.; Li, X.; Shao, M.

    2017-07-01

    At high luminosity area, beam loss monitor with fast response and high radiation resistance is crucial for accelerator operation. In this article, we report the design and test results of a fast response and radiation-resistant scintillator detector as the beam loss monitor for high luminosity collider, especially at low energy region such as RFQ. The detector is consisted of a 2 cm× 2 cm× 0.5 cm LYSO crystal readout by a 6 mm × 6 mm Silicon photomultiplier. Test results from various radioactive sources show that the detector has good sensitivity to photons from tens of keV to several MeV with good linearity and energy resolution (23% for 60 keV γ-ray). For field test, two such detectors are installed outside of the vacuum chamber shell of an 800 MeV electron storage ring. The details of the test and results are introduced.

  5. Scintillating fiber detectors for the HypHI project at GSI

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, D. [GSI Helmholtz Center for Heavy Ion Research, Planckstrasse 1, 64291 Darmstadt (Germany); Department of Physics, Graduate School of Science, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan)], E-mail: D.Nakajima@gsi.de; Ozel-Tashenov, B. [GSI Helmholtz Center for Heavy Ion Research, Planckstrasse 1, 64291 Darmstadt (Germany); Department of Physics, Nigde University, 51100 Nigde (Turkey)], E-mail: B.Oezel@gsi.de; Bianchin, S. [GSI Helmholtz Center for Heavy Ion Research, Planckstrasse 1, 64291 Darmstadt (Germany); Borodina, O. [GSI Helmholtz Center for Heavy Ion Research, Planckstrasse 1, 64291 Darmstadt (Germany); Institut fuer Kernphysik, Johannes Gutenberg Universitaet Mainz, J.J.Becherweg 45, 55099 Mainz (Germany); Bozkurt, V.; Goekuezuem, B. [GSI Helmholtz Center for Heavy Ion Research, Planckstrasse 1, 64291 Darmstadt (Germany); Department of Physics, Nigde University, 51100 Nigde (Turkey); Kavatsyuk, M. [KVI, Zernikelaan 25, NL-9747 AA Groningen (Netherlands); Minami, S. [GSI Helmholtz Center for Heavy Ion Research, Planckstrasse 1, 64291 Darmstadt (Germany); Rappold, C. [GSI Helmholtz Center for Heavy Ion Research, Planckstrasse 1, 64291 Darmstadt (Germany); Universite Louis Pasteur Strasbourg, 4 rue Blaise Pascal, 67070 Strasbourg Cedex (France); Saito, T.R. [GSI Helmholtz Center for Heavy Ion Research, Planckstrasse 1, 64291 Darmstadt (Germany); Institut fuer Kernphysik, Johannes Gutenberg Universitaet Mainz, J.J.Becherweg 45, 55099 Mainz (Germany); Achenbach, P. [Institut fuer Kernphysik, Johannes Gutenberg Universitaet Mainz, J.J.Becherweg 45, 55099 Mainz (Germany); Ajimura, S. [Research Center for Nuclear Physics (RCNP), Osaka University, 10-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Ayerbe, C. [Institut fuer Kernphysik, Johannes Gutenberg Universitaet Mainz, J.J.Becherweg 45, 55099 Mainz (Germany)] (and others)

    2009-09-11

    The construction and properties of three sets of two-dimensional scintillating fiber detector arrays for tracking of charged particles used in the HypHI Phase 0 experiment at GSI will be reported in this paper. The position resolutions and the detection efficiency of detectors have been obtained for each layer of detectors by using {sup 6}Li primary beams and particles with Z=1 produced by fragment reactions of {sup 136}Xe projectiles on the hydrogen target. Besides, the response of energy deposition of charged particles in the first detector set placed right behind the target has been studied by using light projectile fragments with Z=1, 2 and 3 produced by {sup 58}Ni and {sup 12}C beams. Extracted resolutions for energy deposition and position as well as the detection efficiency fulfill the requirements of the HypHI Phase 0 experiment.

  6. Characterization of a scintillating lithium glass ultra-cold neutron detector

    CERN Document Server

    Jamieson, Blair; Hansen-Romu, Sean; Lauss, Bernhard; Lindner, Thomas; Martin, Jeffery W; Pierre, Edgard

    2016-01-01

    A new 6-Li glass based scintillation detector developed for the TRIUMF neutron electric dipole moment experiment was characterized using the ultra-cold neutron source at the Paul Scherrer Institute (PSI). The data acquisition system for this new detector was demonstrated to perform well at rejecting backgrounds. An estimate of the absolute efficiency of background rejection is made as a function of rate. For the variable ultra-cold neutron rate, varying from approx 1 kHz to 100 kHz per channel, and background rate seen at the Paul Scherrer Institut, we estimate that the absolute detector efficiency is 89.7+1.3-1.9 % and the background contamination is 0.3 +- 0.1 %. Finally a comparison with a commercial Cascade detector was performed for a specific setup at the West-2 beamline of the ultra-cold neutron source at PSI.

  7. Evaluation of various planar gaseous detectors with Cs1 photocathodes for the detection of primary scintillation light from noble gases

    CERN Document Server

    Periale, L; Carlson, Per J; Iacobaeus, C; Francke, T; Pavlopoulos, N; Pietropaoplo, F; Sokolova, T; Picchi, P

    2003-01-01

    Noble gases and liquids are excellent scintillators and this opens a unique opportunity to directly detect the primary scintillation light produced in these media by photons or particles. This signal can be used for several purposes, for example as a start signal for TPCs or for particle's identification. Usually photomultipliers (PMs) are used for the detection of the scintillation light. In our previous work we have demonstrated that costly PMs could be replaced by gaseous detectors with CsI photocathodes. Such detectors have the same quantum efficiency as the best PMs but at the same time are cheap, simple and have high position and time resolutions. The aim of this work is to evaluate various planar type gaseous detectors with CsI photocathodes in order to choose the best one for the detection of the primary scintillation light from noble gases and liquids. (10 refs).

  8. High spatial resolution radiation detectors based on hydrogenated amorphous silicon and scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Jing, Tao [Univ. of California, Berkeley, CA (United States). Dept. of Engineering-Nuclear Engineering

    1995-05-01

    Hydrogenated amorphous silicon (a-Si:H) as a large-area thin film semiconductor with ease of doping and low-cost fabrication capability has given a new impetus to the field of imaging sensors; its high radiation resistance also makes it a good material for radiation detectors. In addition, large-area microelectronics based on a-Si:H or polysilicon can be made with full integration of peripheral circuits, including readout switches and shift registers on the same substrate. Thin a-Si:H p-i-n photodiodes coupled to suitable scintillators are shown to be suitable for detecting charged particles, electrons, and X-rays. The response speed of CsI/a-Si:H diode combinations to individual particulate radiation is limited by the scintillation light decay since the charge collection time of the diode is very short (< 10ns). The reverse current of the detector is analyzed in term of contact injection, thermal generation, field enhanced emission (Poole-Frenkel effect), and edge leakage. A good collection efficiency for a diode is obtained by optimizing the p layer of the diode thickness and composition. The CsI(Tl) scintillator coupled to an a-Si:H photodiode detector shows a capability for detecting minimum ionizing particles with S/N ~20. In such an arrangement a p-i-n diode is operated in a photovoltaic mode (reverse bias). In addition, a p-i-n diode can also work as a photoconductor under forward bias and produces a gain yield of 3--8 for shaping times of 1 {micro}s. The mechanism of the formation of structured CsI scintillator layers is analyzed. Initial nucleation in the deposited layer is sensitive to the type of substrate medium, with imperfections generally catalyzing nucleation. Therefore, the microgeometry of a patterned substrate has a significant effect on the structure of the CsI growth.

  9. Effects of Temperature and X-rays on Plastic Scintillating Fiber and Infrared Optical Fiber.

    Science.gov (United States)

    Lee, Bongsoo; Shin, Sang Hun; Jang, Kyoung Won; Yoo, Wook Jae

    2015-05-11

    In this study, we have studied the effects of temperature and X-ray energy variations on the light output signals from two different fiber-optic sensors, a fiber-optic dosimeter (FOD) based on a BCF-12 as a plastic scintillating fiber (PSF) and a fiber-optic thermometer (FOT) using a silver halide optical fiber as an infrared optical fiber (IR fiber). During X-ray beam irradiation, the scintillating light and IR signals were measured simultaneously using a dosimeter probe of the FOD and a thermometer probe of the FOT. The probes were placed in a beaker with water on the center of a hotplate, under variation of the tube potential of a digital radiography system or the temperature of the water in the beaker. From the experimental results, in the case of the PSF, the scintillator light output at the given tube potential decreased as the temperature increased in the temperature range from 25 to 60 °C. We demonstrated that commonly used BCF-12 has a significant temperature dependence of -0.263 ± 0.028%/°C in the clinical temperature range. Next, in the case of the IR fiber, the intensity of the IR signal was almost uniform at each temperature regardless of the tube potential range from 50 to 150 kVp. Therefore, we also demonstrated that the X-ray beam with an energy range used in diagnostic radiology does not affect the IR signals transmitted via a silver halide optical fiber.

  10. Plastic Gamma Sensors: An Application in Detection of Radioisotopes

    Energy Technology Data Exchange (ETDEWEB)

    S. Mukhopadhyay

    2003-06-01

    A brief survey of plastic scintillators for various radiation measurement applications is presented here. The utility of plastic scintillators for practical applications such as gamma radiation monitoring, real-time radioisotope detection and screening is evaluated in laboratory and field measurements. This study also reports results of Monte Carlo-type predictive responses of common plastic scintillators in gamma and neutron radiation fields. Small-size plastic detectors are evaluated for static and dynamic gamma-ray detection sensitivity of selected radiation sources.

  11. Experimental verification of gamma-efficiency calculations for scintillation detectors in ANGLE 4 software

    Directory of Open Access Journals (Sweden)

    Thabet Abouzeid A.

    2015-01-01

    Full Text Available ANGLE software for semiconductor detector efficiency calculations - long existing and widely accepted tool in quantitative gamma spectrometry - has been recently extended to scintillation NaI detectors. The extension features in the latest edition (ANGLE 4 and it is briefly outlined. Discretization of reference efficiency curve, meaning possibility of using ANGLE 4 for particular gamma energies without constructing the complete reference efficiency curve, is particularly emphasized. This yields both in enhanced practicality and higher accuracy, while reducing the potential for systematic errors. The present work is primarily focussed on experimental verification of ANGLE 4 for NaI detectors. Two detectors (2 ´ 2 and 3 x 3 inches were employed in the experiment. Commercially calibrated gamma sources (in the forms of quasi point and cylinder and homemade solutions (diluted from calibrated ones were measured at various distances from the detector(s, ranging 0 cm to 50 cm. Energy range observed was 59 keV to 1408 keV. Versatility of counting conditions, in terms of detectors and sources used, gamma energies observed, source detector separations, etc., was aimed at creating as large experimental evidence as possible for verification purposes. Experimentally obtained efficiencies are compared with those calculated by ANGLE 4. Very good agreement is obtained - well within the experimental uncertainties - thus proving the reliability of the software.

  12. Comparison of a pixelated semiconductor detector and a non-pixelated scintillation detector in pinhole SPECT system for small animal study.

    Science.gov (United States)

    Iida, Hirokazu; Ogawa, Koichi

    2011-02-01

    The aim of this work was to evaluate a pixelated semiconductor detector and non-pixelated scintillation detector in a pinhole SPECT system for small animal imaging. We assumed two pixelated CdTe semiconductor detectors (a monolithic type and a modular type) and two non-pixelated NaI(Tl) scintillation detectors (a conventional type and a large detector field type). For the monolithic semiconductor detector we assumed that the size of a pixel was 1.0 × 1.0 mm², the thickness 1 mm, and an effective detector field 128 × 128 mm². For the modular-type semiconductor detector we assumed that the size of a pixel was 2.5 × 2.5 mm², the thickness 5 mm, and an effective detector field 320 × 320 mm². For the two scintillation detectors we assumed that the size of a pixel was 1.4 × 1.4 mm² and the intrinsic spatial resolution 4.0 mm FWHM, and the thickness 9 mm. For the conventional scintillation detector we assumed that the effective detector field was 179.2 × 179.2 mm², and for the large field scintillation detector 358.2 × 358.2 mm² and the magnification factor two. In the simulation we used a pinhole collimator with a pinhole size of 0.3 mm. We reconstructed SPECT images of hot-rod and cold-channel phantoms with projection data calculated with a Monte Carlo method assuming a fixed data acquisition time, and evaluated the image quality with respect to contrast and spatial resolution. In addition, we calculated the scatter fraction to compare the amount of scattered photons between the pixelated and non-pixelated detectors. The image quality of the modular-type pixelated detector was similar to that of the non-pixelated detector operated with a twofold magnified data acquisition. The scattered photons and the parallax effect in the pixelated detector were small and similar to those in the non-pixelated detector. The performance of a modular-type pixelated semiconductor detector was almost the same as that of a non-pixelated scintillation detector with a magnified

  13. Towards monolithic scintillator based TOF-PET systems: practical methods for detector calibration and operation

    Science.gov (United States)

    Borghi, Giacomo; Tabacchini, Valerio; Schaart, Dennis R.

    2016-07-01

    Gamma-ray detectors based on thick monolithic scintillator crystals can achieve spatial resolutions  published k-NN 1D method. Also, the procedures for estimating the DOI and time of interaction are revised to enable full detector calibration by means of fan-beam or flood irradiations only. Moreover, a new technique is presented to allow the use of events in which some of the photosensor pixel values and/or timestamps are missing (e.g. due to dead time), so as to further increase system sensitivity. The accelerated methods were tested on a monolithic scintillator detector specifically developed for clinical PET applications, consisting of a 32 mm  ×  32 mm  ×  22 mm LYSO : Ce crystal coupled to a digital photon counter (DPC) array. This resulted in a spatial resolution of 1.7 mm FWHM, an average DOI resolution of 3.7 mm FWHM, and a CRT of 214 ps. Moreover, the possibility of using events missing the information of up to 16 out of 64 photosensor pixels is shown. This results in only a small deterioration of the detector performance.

  14. An experimental study of antireflective coatings in Ge light detectors for scintillating bolometers

    Directory of Open Access Journals (Sweden)

    Mancuso M.

    2014-01-01

    Full Text Available Luminescent bolometers are double-readout devices able to measure simultaneously the phonon and the light yields after a particle interaction in the detector. This operation allows in some cases to tag the type of the interacting quantum, crucial issue for background control in rare event experiments such as the search for neutrinoless double beta decay and for interactions of particle dark matter candidates. The light detectors used in the LUCIFER and LUMINEU searches (projects aiming at the study of the double beta interesting candidates 82Se and 100Mo using ZnSe and ZnMoO4 scintillating bolometers consist of hyper-pure Ge thin slabs equipped with NTD thermistors. A substantial sensitivity improvement of the Ge light detectors can be obtained applying a proper anti-reflective coatings on the Ge side exposed to the luminescent bolometer. The present paper deals with the investigation of this aspect, proving and quantifying the positive effect of a SiO2 and a SiO coating and setting the experimental bases for future tests of other coating materials. The results confirm that an appropriate coating procedure helps in improving the sensitivity of bolometric light detectors by an important factor (in the range 20% – 35% and needs to be included in the recipe for the development of an optimized radio-pure scintillating bolometer.

  15. Measurements of response functions of EJ-299-33A plastic scintillator for fast neutrons

    Science.gov (United States)

    Hartman, J.; Barzilov, A.; Peters, E. E.; Yates, S. W.

    2015-12-01

    Monoenergetic neutron response functions were measured for an EJ-299-33A plastic scintillator. The 7-MV Van de Graaff accelerator at the University of Kentucky Accelerator Laboratory was used to produce proton and deuteron beams for reactions with gaseous tritium and deuterium targets, yielding monoenergetic neutrons by means of the 3H(p,n)3He, 2H(d,n)3He, and 3H(d,n)4He reactions. The neutron energy was selected by tuning the charged-particle's energy and using the angular dependence of the neutron emission. The resulting response functions were measured for 0.1-MeV steps in neutron energy from 0.1 MeV to 8.2 MeV and from 12.2 MeV to 20.2 MeV. Experimental data were processed using a procedure for digital pulse-shape discrimination, which allowed characterization of the response functions of the plastic scintillator to neutrons only. The response functions are intended for use in neutron spectrum unfolding methods.

  16. Nanostructured organosilicon luminophores and their application in highly efficient plastic scintillators.

    Science.gov (United States)

    Ponomarenko, Sergei A; Surin, Nikolay M; Borshchev, Oleg V; Luponosov, Yuriy N; Akimov, Dmitry Y; Alexandrov, Ivan S; Burenkov, Alexander A; Kovalenko, Alexey G; Stekhanov, Viktor N; Kleymyuk, Elena A; Gritsenko, Oleg T; Cherkaev, Georgiy V; Kechek'yan, Alexander S; Serenko, Olga A; Muzafarov, Aziz M

    2014-10-08

    Organic luminophores are widely used in various optoelectronic devices, which serve for photonics, nuclear and particle physics, quantum electronics, medical diagnostics and many other fields of science and technology. Improving their spectral-luminescent characteristics for particular technical requirements of the devices is a challenging task. Here we show a new concept to universal solution of this problem by creation of nanostructured organosilicon luminophores (NOLs), which are a particular type of dendritic molecular antennas. They combine the best properties of organic luminophores and inorganic quantum dots: high absorption cross-section, excellent photoluminescence quantum yield, fast luminescence decay time and good processability. A NOL consists of two types of covalently bonded via silicon atoms organic luminophores with efficient Förster energy transfer between them. Using NOLs in plastic scintillators, widely utilized for radiation detection and in elementary particles discoveries, led to a breakthrough in their efficiency, which combines both high light output and fast decay time. Moreover, for the first time plastic scintillators, which emit light in the desired wavelength region ranging from 370 to 700 nm, have been created. We anticipate further applications of NOLs as working elements of pulsed dye lasers in photonics, optoelectronics and as fluorescent labels in biology and medical diagnostics.

  17. Bis(pinacolato)diboron as an additive for the detection of thermal neutrons in plastic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Mahl, Adam [Department of Physics and the Nuclear Science and Engineering Center (NuSEC), Colorado School of Mines, Golden, CO 80401 (United States); Yemam, Henok A.; Stuntz, John [Department of Chemistry and Geochemistry and the Materials Science Program Colorado School of Mines, Golden, CO 80401 (United States); Remedes, Tyler [Department of Physics and the Nuclear Science and Engineering Center (NuSEC), Colorado School of Mines, Golden, CO 80401 (United States); Sellinger, Alan [Department of Chemistry and Geochemistry and the Materials Science Program Colorado School of Mines, Golden, CO 80401 (United States); Greife, Uwe, E-mail: ugreife@mines.edu [Department of Physics and the Nuclear Science and Engineering Center (NuSEC), Colorado School of Mines, Golden, CO 80401 (United States)

    2016-04-21

    A readily available and inexpensive boron compound was tested as an additive for the detection of thermal neutrons in plastic scintillators. Bis(pinacolato)diboron (B{sub 2}Pin{sub 2}) was determined to be a compatible boron source (8.51 wt% boron, 1.70 wt% {sup 10}B) in poly(vinyltoluene) based matrices. Plastic scintillator blends of 1–20 wt% 2,5-diphenyloxazole (PPO), 0.1 wt% 1,4-bis(5-phenyloxazol-2-yl) benzene (POPOP) and 1–15 wt% B{sub 2}Pin{sub 2} were prepared that provided optical clarity, good mechanical properties, and the capability of thermal neutron detection. Independent of B{sub 2}Pin{sub 2} concentration, strong {sup 10}B neutron capture signals around 90 keV{sub ee} were observed at essentially constant light output. Increasing PPO concentration allowed for the use of pulse shape discrimination (PSD) in both fast and thermal neutron detection. High PPO concentrations appear to cause additional alpha quenching that affected the {sup 10}B neutron capture signal. Aging effects after storage in air for several months were observed, which led to degradation of performance and in some samples of mechanical stability.

  18. Assessment of a simulation software for scintillation detector

    CERN Document Server

    Crespin, S; Brette, P; Falvard, A; Maublant, J

    2004-01-01

    Aim: A Monte Carlo code based on GEANT 3.21 and Linux platform has been developed and adaptated to simulate gamma detectors dedicated to specific scintigraphic applications. Materials and methods: GEANT 3.21 is freely available at the CERN program library. It has been written for simulating the interactions of particles with energy greater than 10keV. The energy of the gamma rays used in scintigraphic imaging never exceeds 511keV. Interaction cross- sections for energies between 10keV and 10MeV and three media of interest obtained with this program have been compared with data available on the NIST web site. A gamma peroperative hand-held probe has then been simulated. Sensitivity and spatial resolution were evaluated. Results: The high standard deviation for total attenuation coefficient is 4.7% with an uncertainty around 4% given by NIST. The good results obtained have allowed us to go farther in computer programming. In the hope of integrating all the detection lines new routines have been introduced for t...

  19. Performance of a SiPM based semi-monolithic scintillator PET detector

    Science.gov (United States)

    Zhang, Xianming; Wang, Xiaohui; Ren, Ning; Kuang, Zhonghua; Deng, Xinhan; Fu, Xin; Wu, San; Sang, Ziru; Hu, Zhanli; Liang, Dong; Liu, Xin; Zheng, Hairong; Yang, Yongfeng

    2017-10-01

    A depth encoding PET detector module using semi-monolithic scintillation crystal single-ended readout by a SiPM array was built and its performance was measured. The semi-monolithic scintillator detector consists of 11 polished LYSO slices measuring 1  ×  11.6  ×  10 mm3. The slices are glued together with enhanced specular reflector (ESR) in between and outside of the slices. The bottom surface of the slices is coupled to a 4  ×  4 SiPM array with a 1 mm light guide and silicon grease between them. No reflector is used on the top surface and two sides of the slices to reduce the scintillation photon reflection. The signals of the 4  ×  4 SiPM array are grouped along rows and columns separately into eight signals. Four SiPM column signals are used to identify the slices according to the center of the gravity of the scintillation photon distribution in the pixelated direction. Four SiPM row signals are used to estimate the y (monolithic direction) and z (depth of interaction) positions according to the center of the gravity and the width of the scintillation photon distribution in the monolithic direction, respectively. The detector was measured with 1 mm sampling interval in both the y and z directions with electronic collimation by using a 0.25 mm diameter 22Na point source and a 1  ×  1  ×  20 mm3 LYSO crystal detector. An average slice based energy resolution of 14.9% was obtained. All slices of 1 mm thick were clearly resolved and a detector with even thinner slices could be used. The y positions calculated with the center of gravity method are different for interactions happening at the same y, but different z positions due to depth dependent edge effects. The least-square minimization and the maximum likelihood positioning algorithms were developed and both methods improved the spatial resolution at the edges of the detector as compared with the center of gravity method. A mean absolute error

  20. Production of grids in plastic detectors

    CERN Document Server

    Birabeau, J P; Brun, R; Cordaillat, A; Mendola, Onofrio

    1972-01-01

    In order to facilitate the locating of tracks of charged particles in cellulose nitrate and polycarbonate (makrofol, lexan) foils, a method has been developed for the photo-deposition of translucent coordinate grids on this materials. The grids are resistant to the strongly caustic solutions used in developing tracks in plastic foils. (9 refs) .

  1. Deposition of grids on plastic detectors

    CERN Document Server

    Birabeau, J P; Mendola, Onofrio

    1972-01-01

    In order to facilitate the locating of tracks of charged particles in cellulose-nitrate and polycarbonate (Makrofol, Lexan) foils, a method has been developed for the photo-deposition of translucent coordinate grids on these materials. The grids are resistant to the strongly caustic solutions used in developing tracks in plastic foils. (9 refs) .

  2. Timing tests of silicon-photomultipliers for readout of large plastic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Gohl, Stefan; Cowan, Thomas E.; Roeder, Marko [Helmholtz-Zentrum Dresden-Rossendorf (HZDR) (Germany); TU Dresden (Germany); Bemmerer, Daniel; Heidel, Klaus; Stach, Daniel; Wagner, Andreas; Weinberger, David [Helmholtz-Zentrum Dresden-Rossendorf (HZDR) (Germany); Reinhardt, Tobias [TU Dresden (Germany); Helmholtz-Zentrum Dresden-Rossendorf (HZDR) (Germany); Collaboration: R3B-Collaboration

    2014-07-01

    Silicon Photomultipliers (SiPMs) are under study as a possible replacement for timing photomultiplier tubes (PMTs) in the NeuLAND (New Large Area Neutron Detector) detector at FAIR. SiPMs have several advantages over PMTs. They are insensitive to magnetic fields, small and they can be manufactured economically. Therefore, studies have been made with different SiPMs, preamplifiers and scintillators aiming to find a suitable setup with a good timing resolution for NeuLAND. Some parameters, e.g. bias voltage and light input, were tuned as well. The SiPMs were irradiated with an electron beam at ELBE and a picosecond laser system while the signals were recorded with a digital oscilloscope and evaluated by using a software Constant Fraction Discriminator (CFD). Preliminary results are presented.

  3. Scalability, scintillation readout and charge drift in a kilogram scale solid xenon particle detector

    CERN Document Server

    Yoo, J; Jaskierny, W F; Markley, D; Pahlka, R B; Balakishiyeva, D; Saab, T; Filipenko, M

    2014-01-01

    We report a demonstration of the scalability of optically transparent xenon in the solid phase for use as a particle detector above a kilogram scale. We employ a liquid nitrogen cooled cryostat combined with a xenon purification and chiller system to measure the scintillation light output and electron drift speed from both the solid and liquid phases of xenon. Scintillation light output from sealed radioactive sources is measured by a set of high quantum efficiency photomultiplier tubes suitable for cryogenic applications. We observed a reduced amount of photons in solid phase compared to that in liquid phase. We used a conventional time projection chamber system to measure the electron drift time in a kilogram of solid xenon and observed faster electron drift speed in the solid phase xenon compared to that in the liquid phase.

  4. Scalability, Scintillation Readout and Charge Drift in a Kilogram Scale Solid Xenon Particle Detector

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, J. [Fermilab; Cease, H. [Fermilab; Jaskierny, W. F. [Fermilab; Markley, D. [Fermilab; Pahlka, R. B. [Fermilab; Balakishiyeva, D. [Florida U.; Saab, T. [Florida U.; Filipenko, M. [Erlangen - Nuremberg U., ECAP

    2014-10-23

    We report a demonstration of the scalability of optically transparent xenon in the solid phase for use as a particle detector above a kilogram scale. We employ a liquid nitrogen cooled cryostat combined with a xenon purification and chiller system to measure the scintillation light output and electron drift speed from both the solid and liquid phases of xenon. Scintillation light output from sealed radioactive sources is measured by a set of high quantum efficiency photomultiplier tubes suitable for cryogenic applications. We observed a reduced amount of photons in solid phase compared to that in liquid phase. We used a conventional time projection chamber system to measure the electron drift time in a kilogram of solid xenon and observed faster electron drift speed in the solid phase xenon compared to that in the liquid phase.

  5. Study of influence of plastic scintillators thicknesses to detect Beta particles and Gamma radiation by means of spectral analysis of {sup 90}Sr, {sup 90}Y and {sup 137}Cs sources

    Energy Technology Data Exchange (ETDEWEB)

    Cardenas, Jose Patricio Nahuel; Filho, Tufic Madi; Pereira, Maria da Conceicao Costa; Santos, Brianna B. dos; Correa, Eduardo de L.; Santos, Lucas Rodrigues dos; Lopes, Anderson Figueredo; Silva, Alexandre F.P. da; Santos, Diogo F. dos; Camilo, Douglas de S.; Purgato, Rafael T.; Aredes, Vitor O.G. [Nuclear and Energy Research Institute, IPEN-CNEN/SP, Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, Av. Prof. Lineu Prestes 2242 Cid Universitaria CEP: 05508-000- Sao Paulo-SP (Brazil)

    2015-07-01

    The Nuclear and Energy Research Institute - IPEN, offers post-graduate programs, namely: Nuclear Technology - Applications (TNA), Nuclear Technology - Materials (TNM), Nuclear Technology - Reactors (TNR). The Institute programs mission is to form expert technicians, physicists and engineers with a strong knowledge in their discipline to work in the nuclear area. The course: 'Theoretical Fundamentals and Practices of the Instrumentation used in Nuclear Data Acquisition' covers the use of laboratory nuclear instrumentation and the accomplishment of experiments to obtain nuclear parameters. One of these experimental exercises is object of this work: 'Study of influence of plastic scintillators to detect Beta particles and Gamma radiation by means of spectral analysis of {sup 90}Sr, {sup 90}Y and {sup 137}Cs sources'. The use of scintillators plastic for the detection has the advantage of low cost, high mechanical strength, is not hygroscopic and can be manufactured in large volumes. This work aims to present the analysis of relative efficiency of detection of plastic scintillators of various thicknesses for beta particles and gamma radiation by the spectrum of {sup 137}Cs and {sup 90}Sr. Due to lack of resolution of the detectors plastic scintillators we worked with relative efficiency. The evaluation was done by reading deposited energy, using the software MAESTRO, for each detector thickness. For beta particles was observed an ideal thickness around 3 mm and the better photon efficiency was observed with increasing the thickness of the detector. The present experiment does not intend to establish a new technique for this subject: it solely aims student's practical exercises in nuclear properties of elements and detectors being part of the nuclear experimental course. (authors)

  6. Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques

    CERN Document Server

    Akashi-Ronquest, M; Batygov, M; Beltran, B; Bodmer, M; Boulay, M G; Broerman, B; Buck, B; Butcher, A; Cai, B; Caldwell, T; Chen, M; Chen, Y; Cleveland, B; Coakley, K; Dering, K; Duncan, F A; Formaggio, J A; Gagnon, R; Gastler, D; Giuliani, F; Gold, M; Golovko, V V; Gorel, P; Graham, K; Grace, E; Guerrero, N; Guiseppe, V; Hallin, A L; Harvey, P; Hearns, C; Henning, R; Hime, A; Hofgartner, J; Jaditz, S; Jillings, C J; Kachulis, C; Kearns, E; Kelsey, J; Klein, J R; Kuzniak, M; LaTorre, A; Lawson, I; Li, O; Lidgard, J J; Liimatainen, P; Linden, S; McFarlane, K; McKinsey, D N; MacMullin, S; Mastbaum, A; Mathew, R; McDonald, A B; Mei, D -M; Monroe, J; Muir, A; Nantais, C; Nicolics, K; Nikkel, J A; Noble, T; O'Dwyer, E; Olsen, K; Gann, G D Orebi; Ouellet, C; Palladino, K; Pasuthip, P; Perumpilly, G; Pollmann, T; Rau, P; Retiere, F; Rielage, K; Schnee, R; Seibert, S; Skensved, P; Sonley, T; Vazquez-Jauregui, E; Veloce, L; Walding, J; Wang, B; Wang, J; Ward, M; Zhang, C

    2014-01-01

    Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We describe a Bayesian technique that can identify the times of individual photoelectrons in a sampled PMT waveform without deconvolution, even when pileup is present. To demonstrate the technique, we apply it to the general problem of particle identification in single-phase liquid argon dark matter detectors. Using the output of the Bayesian photoelectron counting algorithm described in this paper, we construct several test statistics for rejection of backgrounds for dark matter searches in argon. Compared to simpler methods based on either observed charge or peak finding, the photoelectron counting technique improves ...

  7. Silicon photomultiplier readout of a monolithic 270×5×5 cm3 plastic scintillator bar for time of flight applications

    Science.gov (United States)

    Reinhardt, Tobias P.; Gohl, Stefan; Reinicke, Stefan; Bemmerer, Daniel; Cowan, Thomas E.; Heidel, Klaus; Röder, Marko; Stach, Daniel; Wagner, Andreas; Weinberger, David; Zuber, Kai

    2016-04-01

    The detection of 200-1000 MeV neutrons requires large amounts, ~ 100 cm, of detector material because of the long nuclear interaction length of these particles. In the example of the NeuLAND neutron time-of-flight detector at FAIR, this is accomplished by using 3000 monolithic scintillator bars of 270 × 5 × 5cm3 size made of a fast plastic. Each bar is read out on the two long ends, and the needed time resolution of σt ELBE superconducting electron linac. The ELBE data were matched by a simple Monte Carlo simulation, and they were found to obey an inverse-square-root scaling law. In the electron beam tests, a time resolution of σt = 136 ps was reached with a pure SiPM readout, well within the design parameters for NeuLAND.

  8. Some characteristics of X-ray imaging for energy region of over 100 keV using plastic scintillation fiber array

    Institute of Scientific and Technical Information of China (English)

    TANG Shibiao; MA Qingli; YIN Zejie; HUANG Huan

    2007-01-01

    In this work, characteristics of using PSFs (plastic scintillation fibers) coupled with CCD (charge-coupled devices ) to build area detectors for high energy X-ray imaging are studied with a Monte Carlo simulation, which cover an energy range of a few hundred kev to about 20 MeV. It was found that the efficiency of PSF in detecting X-ray with energy above a few hundred kev is low. We can use large incident flux to increase the output signal to noise ratio (SNR). The performance can also be improved by coating PSF with X-ray absorption layers and the MTF of the system is presented. By optimizing the absorption layer thickness, the crosstalk of the area detector built with PSF decreases.

  9. A Minor Modification of Leading Edge Discriminator Circuitry with a Delay Line for Baseline Restoration of Scintillation Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Izumi, N

    2003-05-27

    Multi-channel neutron time-of-flight detector arrays LaNSA, T-ion, Medusa, and Mandala, have been used for neutron spectroscopy in inertial confinement fusion experiments. These multi-channel neutron detector arrays consist of many identical scintillation detectors (842 {approx} 1024 channel), data acquisition electronics (discriminators, time-to digital converters, and controller). Each detector element is operated in neutron counting mode. Time-of-flight of individual detected neutrons are recorded by time to digital converters. The energy of each detected neutrons is determined from its time-of-flight. The accurate time measurement ({Delta}t {approx} 0.5 ns) and straightforward statistical features of the data obtained with these systems provides good integrity and reliability. The elements detector used in these systems are organic scintillators coupled with photo multiplier tubes. A scintillation detector operated in particle-counting mode requires finite recovery time after each detection event. The recovery time is determined by the time responses of scintillators, photo multiplier tubes, and the dead times of following discriminators and time-to digital converters. The harsh gamma ray background environment of fast ignitor experiments requires detectors that have fast recovery times. In high intensity laser experiments (I > 10{sup 19} W/cm{sup 2}), strong gamma ray bursts are produced by relativistic laser plasma interactions. Prior to the neutron signal, these strong gamma ray bursts hit the detectors and interfere with the detection of following neutron signals. In these situations, the recovery time of the system after preceding gamma ray bursts is determined mainly by the base line shift of the PMT signal (due to slower decay components of scintillators ''after glow''). Discriminators cannot detect following signal pulses until the proceeding burst decays below its threshold voltage. The base line shift caused by the after glow

  10. Spectral modeling of scintillator for the NEMO-3 and SuperNEMO detectors

    CERN Document Server

    Argyriades, J; Augier, C; Baker, J; Barabash, A S; Bongrand, M; Broudin-Bay, G; Brudanin, V B; Caffrey, A J; Cebrián, S; Chapon, A; Chauveau, E; Dafni, Th; Daraktchieva, Z; iaz, J D; Durand, D; Egorov, V G; Evans, J J; Fatemi-Ghomi, N; Flack, R; Basharina-Freshville, A; Fushimi, K-I; Garrido, X; Gómez, H; Guillon, B; Holin, A; Holy, K; Horkey, J J; Hubert, Ph; Hugon, C; Iguaz, F J; Irastorza, I G; Ishihara, N; Jackson, C M; Jullian, S; Kanamaru, S; Kauer, M; Kochetov, O I; Konovalov, S I; Kovalenko, V E; Lalanne, D; Lang, K; ere, Y Lemi; Lutter, G; Luzón, G; Mamedov, F; Marquet, Ch; Martin-Albo, J; Mauger, F; Monrabal, F; Nachab, A; Nasteva, I; Nemchenok, I B; Nguyen, C H; Nova, F; Novella, P; Ohsumi, H; Pahlka, R B; Perrot, F; Piquemal, F; Povinec, P P; Richards, B; Ricol, J S; Riddle, C L; Rodriguez, A; Saakyan, R; Sarazin, X; Sedgbeer, J K; Serra, L; Simard, L; Šimkovic, F; Shitov, Yu A; Smolnikov, A A; Soldner-Rembold, S; Štekl, I; Sugaya, Y; Sutton, C S; Szklarz, G; Tamagawa, Y; Thomas, J; Thompson, R; Timkin, V V; Tretyak, V I; Tretyak, Vl I; Umatov, V I; ala, L V; Vanyushin, I A; Vasiliev, R; Vorobel, V; Vylov, Ts; Waters, D; Yahlali, N; Žukauskas, A

    2010-01-01

    We have constructed a GEANT4-based detailed software model of photon transport in plastic scintillator blocks and have used it to study the NEMO-3 and SuperNEMO calorimeters employed in experiments designed to search for neutrinoless double beta decay. We compare our simulations to measurements using conversion electrons from a calibration source of $\\rm ^{207}Bi$ and show that the agreement is improved if wavelength-dependent properties of the calorimeter are taken into account. In this article, we briefly describe our modeling approach and results of our studies.

  11. Fission signal detection using helium-4 gas fast neutron scintillation detectors

    Science.gov (United States)

    Lewis, J. M.; Kelley, R. P.; Murer, D.; Jordan, K. A.

    2014-07-01

    We demonstrate the unambiguous detection of the fission neutron signal produced in natural uranium during active neutron interrogation using a deuterium-deuterium fusion neutron generator and a high pressure 4He gas fast neutron scintillation detector. The energy deposition by individual neutrons is quantified, and energy discrimination is used to differentiate the induced fission neutrons from the mono-energetic interrogation neutrons. The detector can discriminate between different incident neutron energies using pulse height discrimination of the slow scintillation component of the elastic scattering interaction between a neutron and the 4He atom. Energy histograms resulting from this data show the buildup of a detected fission neutron signal at higher energies. The detector is shown here to detect a unique fission neutron signal from a natural uranium sample during active interrogation with a (d, d) neutron generator. This signal path has a direct application to the detection of shielded nuclear material in cargo and air containers. It allows for continuous interrogation and detection while greatly minimizing the potential for false alarms.

  12. Characterization of a scintillating fibers read by MPPC detectors trigger prototype for the AMADEUS experiment

    CERN Document Server

    Scordo, A; Berucci, C; Curceanu, C; D'Uffizi, A; Piscicchia, K; Lener, M Poli; Vidal, A Romero; Sbardella, E; Doce, O Vazquez

    2013-01-01

    Multi-Pixel Photon Counters (MPPC) consist of hundreds of micro silicon Avalanche PhotoDiodes (APD) working in Geiger mode. The high gain and the low noise, typical of these devices, together with their good performance in magnetic field, make them ideal readout detectors for scintillating fibers as trigger detectors in particle and nuclear physics experiments like AMADEUS, where such detectors are planned to be used to trigger on charged kaon pairs. In order to investigate the detection efficiency of such a system, a prototype setup consisting of 32, 1 mm diameter scintillating fibers, arranged in two double layers of 16 fibers each, and read out by 64 MPPCs with an ad-hoc built readout electronics, was tested at the piM-1 line of the Paul Scherrer Institute (PSI) in Villigen, Switzerland. The detection efficiency and the trigger capability were measured on a beam containing protons, electrons, muons and pions with a momentum of 440 MeV/c. The measured average efficiency for protons for a double layer of sci...

  13. The Aachen muon detector prototype. Muon measurement using scintillator tiles with SiPM readout

    Energy Technology Data Exchange (ETDEWEB)

    Meissner, Rebecca; Bretz, Thomas; Hebbeker, Thomas; Lauscher, Markus; Middendorf, Lukas; Niggemann, Tim; Peters, Christine; Schumacher, Johannes [III. Physikalisches Institut A, RWTH Aachen University (Germany); Collaboration: Pierre Auger-Collaboration

    2015-07-01

    Muons being produced in air showers of ultra high energy cosmic rays carry important information on their characteristics such as the mass of the primary particle and the first hadronic interactions at the highest energies. In the context of the Pierre Auger Observatory this upgrade would enable an enhanced primary particle identification as well as the verification of shower simulation models. For this purpose, a simple and robust detector design with scintillator tiles and SiPM readout is being developed, the Aachen Muon Detector (AMD). AMD could be situated below the SD tanks which would provide shielding from the electromagnetic part of the shower. In total, 64 scintillating tiles form the sensitive area of the detector. Wavelength-shifting fibres are inserted into the tiles in sigma-shape to collect the light and are coupled to optical fibres to guide it onto the photosensitive SiPMs. By reading out each SiPM individually, an excellent and low-background performance is expected. Currently the AMD prototype is being built in Aachen and in parallel SiPM and electronics characteristics are being evaluated.

  14. Development of a new neutron monitor using a boron-loaded organic liquid scintillation detector

    Energy Technology Data Exchange (ETDEWEB)

    Rasolonjatovo, A.H.D.; Shiomi, T.; Kim, E.; Nakamura, T. E-mail: nakamura@cyric.tohoku.ac.jp; Nunomiya, T.; Endo, A.; Yamaguchi, Y.; Yoshizawa, M

    2002-10-21

    A new type of neutron dose monitor was developed by using a 12.7 cm diameterx12.7 cm long boron-loaded organic liquid scintillation detector BC523A. This detector aims to have a response in the wide energy range of thermal energy to 100 MeV by using the H and C reactions to the fast neutrons of organic liquid and the {sup 10}B(n, {alpha}) reaction to thermalized neutrons in the liquid. The response functions of this detector were determined by the Monte Carlo simulation in the energy region from thermal energy to 100 MeV. Using these response functions, the spectrum-weighted dose function, G-function, to get the neutron dose from the light output spectrum of the detector was also determined by the unfolding technique. The calculated G-function was applied to determine the neutron dose in real neutron fields having energies ranging from thermal energy to several tens of MeV, where the light output spectra were measured with the BC523A detector. The thus-obtained ambient doses and effective doses show rather good agreement with the fluence-to-dose conversion factor given by ICRP 74. This detector will be useful as a wide-energy range neutron monitor.

  15. Discrimination of charged particles in a neutral beam line by using a solid scintillation detector

    Science.gov (United States)

    Woo, Jong-Kwan; Ko, Jewou; Liu, Dong

    2017-01-01

    In the past several decades, many studies have been conducted to search for non-baryonic dark matter, such as weakly interactive massive particles (WIMPs). In the search for WIMPs, charged particles incident on the detector are background particles because WIMPs are neutral. Charged particles originate from various sources, such as cosmic rays and laboratory materials surrounding the main detector. Therefore, a veto that discriminates charged particles can improve the particle-detection efficiency of the entire experiment for detecting WIMPs. Here, we investigate in the thickness range of 1 mm to 5 mm, the optimal thickness of a polystyrene scintillator as a chargedparticle veto detector. We found that 3-mm-thick polystyrene provides the best performance to veto charged particles and the charged-particle background in the search for the WIMP signal. Furthermore, we fabricated 3-mm-thick and 5-mm-thick polystyrene charged particle veto detectors that will be used in an underground laboratory in the search for WIMP dark matter. After exposing those detectors are the actual beam line, we compared the rate of charged particles measured using those detectors and the rate simulated through a Monte Carlo simulation.

  16. Analysis of the scintillation mechanism in a pressurized 4He fast neutron detector using pulse shape fitting

    OpenAIRE

    R.P. Kelley; Murer, D.; Ray, H.; K.A. Jordan

    2015-01-01

    An empirical investigation of the scintillation mechanism in a pressurized 4He gas fast neutron detector was conducted using pulse shape fitting. Scintillation signals from neutron interactions were measured and averaged to produce a single generic neutron pulse shape from both a 252Cf spontaneous fission source and a (d,d) neutron generator. An expression for light output over time was then developed by treating the decay of helium excited states in the same manner as the decay of radioactiv...

  17. Pulse-shape discrimination of the new plastic scintillators in neutron-gamma mixed field using fast digitizer card

    Science.gov (United States)

    Jančář, A.; Kopecký, Z.; Dressler, J.; Veškrna, M.; Matěj, Z.; Granja, C.; Solar, M.

    2015-11-01

    Recently invented plastic scintillator EJ-299-33 enables pulse-shape discrimination (PSD) and thus measurement of neutron and photon spectra in mixed fields. In this work we compare the PSD properties of EJ-299-33 plastic and the well-known NE-213 liquid scintillator in monoenergetic neutron fields generated by the Van de Graaff accelerator using the 3H(d, n)4He reaction. Pulses from the scintillators are processed by a newly developed digital measuring system employing the fast digitizer card. This card contains two AD converters connected to the measuring computer via 10 Gbps optical ethernet. The converters operate with a resolution of 12 bits and have two differential inputs with a sampling frequency 1 GHz. The resulting digital channels with different gains are merged into one composite channel with a higher digital resolution in a wide dynamic range of energies. Neutron signals are fully discriminated from gamma signals. Results are presented.

  18. Alignment of the Near Detector scintillator modules using cosmic ray muons

    Energy Technology Data Exchange (ETDEWEB)

    Ospanov, Rustem; Lang, Karol; /Texas U.

    2008-05-01

    The authors describe the procedures and the results of the first alignment of the Near Detector. Using 15.5 million cosmic ray muon tracks, collected from October, 2004 through early january, 2005, they derive the effective transverse positions of the calorimeter scintillator modules. The residuals from straight line fits indicate that the current alignment has achieved better than 1 mm precision. They estimate the size of the remaining misalignment and using tracks recorded with a magnetic field test the effect of the magnetic field on the alignment.

  19. Imaging the LHC beams with silicon and scintillating fibre vertex detectors

    Science.gov (United States)

    Rihl, M.

    2017-02-01

    The LHCb Vertex Locator (VELO) is used to reconstruct beam-gas interaction vertices which allows one to obtain precise profiles of the LHC beams. In LHCb, this information is combined with the profile of the reconstructed beam-beam collisions and with the LHC beam currents to perform precise measurements of the luminosity. This beam-gas imaging (BGI) method also allows one to study the transverse beam shapes, beam positions and angles in real time. Therefore, a demonstrator beam-gas vertex detector (BGV) based on scintillating fibre modules has been built and installed in LHC Ring 2 at point 4.

  20. Imaging the LHC beams with silicon and scintillating fibre vertex detectors

    CERN Document Server

    Rihl, M

    2016-01-01

    The LHCb Vertex Locator (VELO) is used to reconstruct beam–gas interaction vertices which allows one to obtain precise profiles of the LHC beams. In LHCb, this information is combined with the profile of the reconstructed beam–beam collisions and with the LHC beam currents to perform precise measurements of the luminosity. This beam–gas imaging (BGI) method also allows one to study the transverse beam shapes, beam positions and angles in real time. Therefore, a demonstrator beam–gas vertex detector (BGV) based on scintillating fibre modules has been built and installed in LHC Ring 2 at point 4.

  1. The Front End Electronics of the Scintillator Pad Detector of LHCb Calorimeter

    CERN Document Server

    Gascon, David; Bota, S; Comerma, A; Diéguez, A; Garrido, L; Gaspar, A; Graciani, R; Graciani, E; Herms, A; Llorens, M; Luengo, S; Picatoste, E; Riera, J; Rosselló, M; Ruiz, H; Tortella, S; Vilasís, X

    2007-01-01

    In this paper the Front End electronics of the Scintillator Pad Detector (SPD) is outlined. The SPD is a sub-system of the Calorimeter of the LHCb experiment designed to discriminate between charged and neutral particles for the first level trigger. The system design is presented, describing its different functionalities implemented through three different cards and several ASICs. These functionalities are signal processing and digitization, data transmission, interface with control and timing systems of the experiment, low voltage power supply distribution and monitoring. Special emphasis is placed on installation and commissioning subjects such as cabling, grounding, shielding and power distribution.

  2. A rope-net support system for the liquid scintillator detector for the SNO+ experiment

    Energy Technology Data Exchange (ETDEWEB)

    Bialek, A., E-mail: abialek@snolab.ca [University of Alberta, Edmonton (Canada); Chen, M. [Queen' s University, Kingston (Canada); Cleveland, B. [SNOLAB, Lively (Canada); Gorel, P.; Hallin, A. [University of Alberta, Edmonton (Canada); Harvey, P.J.; Heise, J. [Queen' s University, Kingston (Canada); Kraus, C. [Laurentian University, Sudbury (Canada); Krauss, C.B. [University of Alberta, Edmonton (Canada); Lawson, I. [SNOLAB, Lively (Canada); Ng, C.J.; Pinkney, B. [University of Alberta, Edmonton (Canada); Rogowsky, D.M. [Rogowsky Engineering Ltd, AECOM Canada Ltd (Canada); Sibley, L.; Soluk, R.; Soukup, J. [University of Alberta, Edmonton (Canada); Vázquez-Jáuregui, E. [SNOLAB, Lively (Canada); Laurentian University, Sudbury (Canada)

    2016-08-11

    The detector for the SNO+ experiment consists of 780 000 kg of liquid scintillator contained in an acrylic vessel that is surrounded by water. A mechanical system has been installed to counteract the 1.25 MN of buoyant force on the acrylic and prevent the vessel from moving. The system is a rope net, designed using a Finite Element Analysis to calculate the amount of stress on the acrylic induced by the ropes, hydrostatic pressures and gravity. A dedicated test was performed to measure strains in the acrylic arising from the complex geometry of the knots in the rope system. The ratio between measured and FEA calculated strains was 1.3.

  3. Measurements of prompt fission gamma-rays and neutrons with lanthanide halide scintillation detectors

    CERN Document Server

    Oberstedt, A; Billnert, R; Borcea, R; Brys, T; Chaves, C; Gamboni, T; Geerts, W; Göök, A; Guerrero, C; Hambsch, F-J; Kis, Z; Martinez, T; Oberstedt, S; Szentmiklosi, L; Takács, K; Vivaldi, M

    2014-01-01

    Photons have been measured with lanthanide halide scintillation detectors in coincidence with fission fragments. Using the time-of-flight information, reactions from γ-rays and neutrons could easily be distinguished. In several experiments on $^{252}$Cf(sf), $^{235}$U(n$_{th}$,f) and $^{241}$Pu(n$_{th}$,f) prompt fission γ-ray spectra characteristics were determined with high precision and the results are presented here. Moreover, a measured prompt fission neutron spectrum for $^{235}$U(n$_{th}$,f) is shown in order to demonstrate a new detection technique.

  4. Imaging the LHC beams with silicon and scintillating fibre vertex detectors

    CERN Document Server

    Rihl, M

    2016-01-01

    The LHCb Vertex Locator (VELO) is used to reconstruct beam–gas interaction vertices which allows one to obtain precise profiles of the LHC beams. In LHCb, this information is combined with the profile of the reconstructed beam–beam collisions and with the LHC beam currents to perform precise measurements of the luminosity. This beam–gas imaging (BGI) method also allows one to study the transverse beam shapes, beam positions and angles in real time. Therefore, a demonstrator beam–gas vertex detector (BGV) based on scintillating fibre modules has been built and installed in LHC Ring 2 at point 4.

  5. Neutron imaging detector with 2 μm spatial resolution based on event reconstruction of neutron capture in gadolinium oxysulfide scintillators

    Science.gov (United States)

    Hussey, Daniel S.; LaManna, Jacob M.; Baltic, Elias; Jacobson, David L.

    2017-09-01

    We report on efforts to improve the achievable spatial resolution in neutron imaging by centroiding the scintillation light from gadolinium oxysulfide scintillators. The current state-of-the-art neutron imaging spatial resolution is about 10 μm, and many applications of neutron imaging would benefit from at least an order of magnitude improvement in the spatial resolution. The detector scheme that we have developed magnifies the scintillation light from a gadolinium oxysulfide scintillator, calculates the center of mass of the scintillation event, resulting in an event-based imaging detector with spatial resolution of about 2 μm.

  6. Study and simulation of the read-out electronics design for a high-resolution plastic scintillating fiber based hodoscope

    Energy Technology Data Exchange (ETDEWEB)

    Blasco, José María, E-mail: jose.maria.blasco@uv.es [Universitat de València, Calle Gascó Oliag n" o5, 46010, Valencia (Spain); Sanchis, E. [Universitat de València, Calle Gascó Oliag n" o5, 46010, Valencia (Spain); Granero, D. [Eresa Grupo Médico (Spain); Martín, J.D.; González, V.; Sanchis-Sánchez, E. [Universitat de València, Calle Gascó Oliag n" o5, 46010, Valencia (Spain)

    2015-06-01

    Highlights: • Plastic Scintillating Fibers for high-resolution hodoscopy. • Silicon photodiode read-out electronics design. • Plastic scintillating fibers coupled to Silicon photodiodes read-out. • Charged particle detection with plastic scintillating fibers. - Abstract: This work presents the study and simulation of a high-resolution charged particle detection device for beam positioning, monitoring and calibration, together with its read-out proposal. To provide the precise positional information of the beam, the detection system has been based on Plastic Scintillating Fibers (PSF), while the read-out on a Silicon-PhotoDiode (Si-PD) array. To carry out the study, a PSF prototype with one detection plane has been experimentally tested with a β particle source. Besides, Monte Carlo simulations of the complete system have also been conducted. Both simulations and experimental tests give consistency to the results obtained. The work presented in this article show the usefulness of this proposal for high-precision charged particle positioning, achieving resolutions up to 100 µm.

  7. Development and Testing of Scintillating Detectors for the Muon g-2 Experiment

    Science.gov (United States)

    Martinez, Benjamin; Diamond, Edward; Sblendorio, Alec; Gray, Frederick

    2016-09-01

    The precise value of the muon's anomalous magnetic moment that was measured at Brookhaven National Laboratory E821 differed by more than three standard deviations from predictions of the Standard Model. The Muon g-2 Experiment at Fermilab will attain a more precise measurement by a factor of three by observing the muon spin precession frequency in a magnetic field. This improved measurement could lead to evidence of physics beyond the Standard Model. A thin-scintillator entrance (T0) counter prototype is being tested for possible use in the experiment to determine the intensity and temporal profile of the beam as it is injected into the muon storage ring. The counter is also being evaluated to determine whether it can monitor undesired particles that arrive after the main beam pulse. The unique design of the entrance counter uses a silicon photomultiplier to read the light output from a scintillator. The progress of the design of the T0 entrance counter along with the results of light output tests from a beta source and the SLAC high-energy electron beam are the primary foci of this presentation. The status of scintillating fiber harp beam monitor detectors that will also be used in the g-2 Experiment to detect the position and width of the muon beam will also be presented. This material is based upon work supported by the National Science Foundation under Grant No. PHY-1505887.

  8. Effects of Temperature and X-rays on Plastic Scintillating Fiber and Infrared Optical Fiber

    Directory of Open Access Journals (Sweden)

    Bongsoo Lee

    2015-05-01

    Full Text Available In this study, we have studied the effects of temperature and X-ray energy variations on the light output signals from two different fiber-optic sensors, a fiber-optic dosimeter (FOD based on a BCF-12 as a plastic scintillating fiber (PSF and a fiber-optic thermometer (FOT using a silver halide optical fiber as an infrared optical fiber (IR fiber. During X-ray beam irradiation, the scintillating light and IR signals were measured simultaneously using a dosimeter probe of the FOD and a thermometer probe of the FOT. The probes were placed in a beaker with water on the center of a hotplate, under variation of the tube potential of a digital radiography system or the temperature of the water in the beaker. From the experimental results, in the case of the PSF, the scintillator light output at the given tube potential decreased as the temperature increased in the temperature range from 25 to 60 °C. We demonstrated that commonly used BCF-12 has a significant temperature dependence of −0.263 ± 0.028%/°C in the clinical temperature range. Next, in the case of the IR fiber, the intensity of the IR signal was almost uniform at each temperature regardless of the tube potential range from 50 to 150 kVp. Therefore, we also demonstrated that the X-ray beam with an energy range used in diagnostic radiology does not affect the IR signals transmitted via a silver halide optical fiber.

  9. 2-(2{prime}-hydroxyphenyl)benzothiazoles, -benzoxazoles, and -benzimidazoles for plastic scintillation applications

    Energy Technology Data Exchange (ETDEWEB)

    Pla-Dalmau, A. [Fermi National Accelerator Lab., Batavia, IL (United States)

    1995-08-25

    A new series of fluorescent compounds has been tested as dopants for plastic scintillation applications. Several 2-(2{prime}-hydroxyphenyl)benzothiazole, -benzoxazole, and -benzimidazole derivatives have been prepared and studied in a polystyrene matrix. Each derivative has been added to a styrene solution which has been thermally polymerized. The transmittance, fluorescence, and light yield characteristics of these compounds in polystyrene have been determined. Their emission time distributions have also been measured, and the decay time constants have been calculated from these data. In addition, the doped polystyrene samples have been irradiated to a total dose of 10 Mrad, utilizing a {sup 60}Co source in order to evaluate their susceptibility to radiation-induced damage. 6 figs., 1 tab.

  10. Development of a new neutron monitor using a boron-loaded organic liquid scintillation detector

    CERN Document Server

    Rasolonjatovo, A H D; Kim, E; Nakamura, T; Nunomiya, T; Endo, A; Yamaguchi, Y; Yoshizawa, M

    2002-01-01

    A new type of neutron dose monitor was developed by using a 12.7 cm diameterx12.7 cm long boron-loaded organic liquid scintillation detector BC523A. This detector aims to have a response in the wide energy range of thermal energy to 100 MeV by using the H and C reactions to the fast neutrons of organic liquid and the sup 1 sup 0 B(n, alpha) reaction to thermalized neutrons in the liquid. The response functions of this detector were determined by the Monte Carlo simulation in the energy region from thermal energy to 100 MeV. Using these response functions, the spectrum-weighted dose function, G-function, to get the neutron dose from the light output spectrum of the detector was also determined by the unfolding technique. The calculated G-function was applied to determine the neutron dose in real neutron fields having energies ranging from thermal energy to several tens of MeV, where the light output spectra were measured with the BC523A detector. The thus-obtained ambient doses and effective doses show rather ...

  11. A novel, SiPM-array-based, monolithic scintillator detector for PET.

    Science.gov (United States)

    Schaart, Dennis R; van Dam, Herman T; Seifert, Stefan; Vinke, Ruud; Dendooven, Peter; Löhner, Herbert; Beekman, Freek J

    2009-06-07

    Silicon photomultipliers (SiPMs) are of great interest to positron emission tomography (PET), as they enable new detector geometries, for e.g., depth-of-interaction (DOI) determination, are MR compatible, and offer faster response and higher gain than other solid-state photosensors such as avalanche photodiodes. Here we present a novel detector design with DOI correction, in which a position-sensitive SiPM array is used to read out a monolithic scintillator. Initial characterization of a prototype detector consisting of a 4 x 4 SiPM array coupled to either the front or back surface of a 13.2 mm x 13.2 mm x 10 mm LYSO:Ce(3+) crystal shows that front-side readout results in significantly better performance than conventional back-side readout. Spatial resolutions <1.6 mm full-width-at-half-maximum (FWHM) were measured at the detector centre in response to an approximately 0.54 mm FWHM diameter test beam. Hardly any resolution losses were observed at angles of incidence up to 45 degrees , demonstrating excellent DOI correction. About 14% FWHM energy resolution was obtained. The timing resolution, measured in coincidence with a BaF(2) detector, equals 960 ps FWHM.

  12. A novel, SiPM-array-based, monolithic scintillator detector for PET

    Energy Technology Data Exchange (ETDEWEB)

    Schaart, Dennis R; Dam, Herman T van; Seifert, Stefan; Beekman, Freek J [Delft University of Technology, Radiation Detection and Medical Imaging, Mekelweg 15, 2629 JB Delft (Netherlands); Vinke, Ruud; Dendooven, Peter; Loehner, Herbert [Kernfysisch Versneller Instituut, University of Groningen, Zernikelaan 25, 9747 AA, Groningen (Netherlands)], E-mail: d.r.schaart@tudelft.nl

    2009-06-07

    Silicon photomultipliers (SiPMs) are of great interest to positron emission tomography (PET), as they enable new detector geometries, for e.g., depth-of-interaction (DOI) determination, are MR compatible, and offer faster response and higher gain than other solid-state photosensors such as avalanche photodiodes. Here we present a novel detector design with DOI correction, in which a position-sensitive SiPM array is used to read out a monolithic scintillator. Initial characterization of a prototype detector consisting of a 4 x 4 SiPM array coupled to either the front or back surface of a 13.2 mm x 13.2 mm x 10 mm LYSO:Ce{sup 3+} crystal shows that front-side readout results in significantly better performance than conventional back-side readout. Spatial resolutions <1.6 mm full-width-at-half-maximum (FWHM) were measured at the detector centre in response to an {approx}0.54 mm FWHM diameter test beam. Hardly any resolution losses were observed at angles of incidence up to 45 deg., demonstrating excellent DOI correction. About 14% FWHM energy resolution was obtained. The timing resolution, measured in coincidence with a BaF{sub 2} detector, equals 960 ps FWHM.

  13. Scintillating fiber detectors for precise time and position measurements read out with Si-PMs

    Science.gov (United States)

    Damyanova, A.; Bravar, A.

    2017-02-01

    We present the development and performance of compact scintillating fiber detectors read out with silicon photo-multipliers (Si-PMs). The compact size, fast response, and insensitivity to magnetic fields make these detectors suitable for a variety of applications where precise tracking and timing information is required. These detectors will be used with different particle beams (electrons, protons, heavy ions) at very high rates. In particular, we present the SciFi tracker/time of flight detector that is being developed for the Mu3e experiment at PSI (search for the lepton flavor violating decay μ → eee at very high rates). We also present the SciFi beam position detectors that will be employed in NA61 at CERN to track the incoming proton and heavy ion beam particles. We are considering different readout scenarios in which (a) each fiber is individually coupled to a single Si-PM photo-sensor and (b) fibers are arranged in columns and coupled to a Si-PM arrays.

  14. Unfolding the fast neutron spectra of a BC501A liquid scintillation detector using GRAVEL method

    CERN Document Server

    Chen, Yonghao; Lei, Jiarong; An, Li; Zhang, Xiaodong; Shao, Jianxiong; Zheng, Pu; Wang, Xinhua

    2013-01-01

    Accurate knowledge of the neutron energy spectra is useful in basic research and applications. The overall procedure of measuring and unfolding the fast neutron energy spectra with BC501A liquid scintillation detector is described. The recoil proton spectrum of Am-Be neutrons was obtained experimentally. With the NRESP7 code, the response matrix of detector was simulated. Combining the recoil proton spectrum and response matrix, the unfolding of neutron spectra was performed by GRAVEL iterative algorithm. A MatLab program based on the GRAVEL method was developed. The continuous neutron spectrum of Am-Be source and monoenergetic neutron spectrum of D-T source have been unfolded successfully and are in good agreement with their standard reference spectra. The unfolded Am-Be spectrum are more accurate than the spectra unfolded by artificial neural networks in recent years.

  15. Unfolding the fast neutron spectra of a BC501A liquid scintillation detector using GRAVEL method

    Science.gov (United States)

    Chen, YongHao; Chen, XiMeng; Lei, JiaRong; An, Li; Zhang, XiaoDong; Shao, JianXiong; Zheng, Pu; Wang, XinHua

    2014-10-01

    Accurate knowledge of the neutron energy spectra is useful in basic research and applications. The overall procedure of measuring and unfolding the fast neutron energy spectra with BC501A liquid scintillation detector is described. The recoil proton spectrum of 241Am-Be neutrons was obtained experimentally. With the NRESP7 code, the response matrix of detector was simulated. Combining the recoil proton spectrum and response matrix, the unfolding of neutron spectra was performed by GRAVEL iterative algorithm. A MatLab program based on the GRAVEL method was developed. The continuous neutron spectrum of 241Am-Be source and monoenergetic neutron spectrum of D-T source have been unfolded successfully and are in good agreement with their standard reference spectra. The unfolded 241Am-Be spectrum are more accurate than the spectra unfolded by artificial neural networks in recent years.

  16. Digital discrimination of neutrons and gamma-rays in organic scintillation detectors using moment analysis

    Science.gov (United States)

    Xie, Xufei; Zhang, Xing; Yuan, Xi; Chen, Jinxiang; Li, Xiangqing; Zhang, Guohui; Fan, Tieshuan; Yuan, Guoliang; Yang, Jinwei; Yang, Qingwei

    2012-09-01

    Digital discrimination of neutron and gamma-ray events in an organic scintillator has been investigated by moment analysis. Signals induced by an americium-beryllium (Am/Be) isotropic neutron source in a stilbene crystal detector have been sampled with a flash analogue-to-digital converter (ADC) of 1 GSamples/s sampling rate and 10-bit vertical resolution. Neutrons and gamma-rays have been successfully discriminated with a threshold corresponding to gamma-ray energy about 217 keV. Moment analysis has also been verified against the results assessed by a time-of-flight (TOF) measurement. It is shown that the classification of neutrons and gamma-rays afforded by moment analysis is consistent with that achieved by digital TOF measurement. This method has been applied to analyze the data acquired from the stilbene crystal detector in mixed radiation field of the HL-2A tokamak deuterium plasma discharges and the results are described.

  17. Active neutron methods for nuclear safeguards applications using Helium-4 gas scintillation detectors

    Science.gov (United States)

    Lewis, Jason M.

    Active neutron methods use a neutron source to interrogate fissionable material. In this work a 4He gas scintillation fast neutron detection system is used to measure neutrons created by the interrogation. Three new applications of this method are developed: spent nuclear fuel assay, fission rate measurement, and special nuclear material detection. Three active neutron methods are included in this thesis. First a non-destructive plutonium assay technique called Multispectral Active Neutron Interrogation Analysis is developed. It is based on interrogating fuel with neutrons at several different energies. The induced fission rates at each interrogation energy are compared with results from a neutron transport model of the irradiation geometry in a system of equations to iteratively solve the inverse problem for isotopic composition. The model is shown to converge on the correct composition for a material with 3 different fissionable components, a representative neutron absorber, and any neutron transparent material such as oxygen in a variety of geometries. Next an experimental fission rate measurement technique is developed using 4He gas scintillation fast neutron detector. Several unique features of this detector allow it to detect and provide energy information on fast neutrons with excellent gamma discrimination efficiency. The detector can measure induced fission rate by energetically differentiating between interrogation neutrons and higher energy fission neutrons. The detector response to a mono-energetic deuterium-deuterium fusion neutron generator and a 252Cf source are compared to examine the difference in detected energy range. Finally we demonstrate a special nuclear material detection technique by detecting an unambiguous fission neutron signal produced in natural uranium during active neutron interrogation using a deuterium-deuterium neutron generator and a high pressure 4He gas fast neutron scintillation detector. Energy histograms resulting from this

  18. Error correction and fast detectors implemented by ultrafast neuronal plasticity.

    Science.gov (United States)

    Vardi, Roni; Marmari, Hagar; Kanter, Ido

    2014-04-01

    We experimentally show that the neuron functions as a precise time integrator, where the accumulated changes in neuronal response latencies, under complex and random stimulation patterns, are solely a function of a global quantity, the average time lag between stimulations. In contrast, momentary leaps in the neuronal response latency follow trends of consecutive stimulations, indicating ultrafast neuronal plasticity. On a circuit level, this ultrafast neuronal plasticity phenomenon implements error-correction mechanisms and fast detectors for misplaced stimulations. Additionally, at moderate (high) stimulation rates this phenomenon destabilizes (stabilizes) a periodic neuronal activity disrupted by misplaced stimulations.

  19. Silicon photomultiplier readout of a monolithic 270$\\times$5$\\times$5 cm$^3$ plastic scintillator bar for time of flight applications

    CERN Document Server

    Reinhardt, Tobias P; Reinicke, Stefan; Bemmerer, Daniel; Cowan, Thomas E; Heidel, Klaus; Röder, Marko; Stach, Daniel; Wagner, Andreas; Weinberger, David; Zuber, Kai

    2016-01-01

    The detection of 200-1000 MeV neutrons requires large amounts, $\\sim$100 cm, of detector material because of the long nuclear interaction length of these particles. In the example of the NeuLAND neutron time-of-flight detector at FAIR, this is accomplished by using 3000 monolithic scintillator bars of 270$\\times$5$\\times$5 cm$^3$ size made of a fast plastic. Each bar is read out on the two long ends, and the needed time resolution of $\\sigma_t$ $<$ 150 ps is reached with fast timing photomultipliers. In the present work, it is investigated whether silicon photomultiplier (SiPM) photosensors can be used instead. Experiments with a picosecond laser system were conducted to determine the timing response of the assembly made up of SiPM and preamplifier. The response of the full system including also the scintillator was studied using 30 MeV single electrons provided by the ELBE superconducting electron linac. The ELBE data were matched by a simple Monte Carlo simulation, and they were found to obey an inverse-...

  20. Characterization of scintillator materials for fast-ion loss detectors in nuclear fusion reactors

    Science.gov (United States)

    Jiménez-Ramos, M. C.; García López, J.; García-Muñoz, M.; Rodríguez-Ramos, M.; Carmona Gázquez, M.; Zurro, B.

    2014-08-01

    In fusion plasma reactors, fast ion generated by heating systems and fusion born particles must be well confined. The presence of magnetohydrodynamic (MHD) instabilities can lead to a significant loss of these ions, which may reduce drastically the heating efficiency and may cause damage to plasma facing components in the vacuum vessel. In order to understand the physics underlying the fast ion loss mechanism, scintillator based detectors have been installed in several fusion devices. In this work we present the absolute photon yield and its degradation with ion fluence in terms of the number of photons emitted per incident ion of several scintillators thin coatings: SrGa2S4:Eu2+ (TG-Green), Y3Al5O12:Ce3+ (P46) and Y2O3:Eu3+ (P56) when irradiated with light ions of different masses (deuterium ions, protons and α-particles) at energies between approximately 575 keV and 3 MeV. The photon yield will be discussed in terms of the energy deposited by the particles into the scintillator. For that, the actual composition and thickness of the thin layers were determined by Rutherford Backscattering Spectrometry (RBS). A collimator with 1 mm of diameter, which defines the beam size for the experiments, placed at the entrance of the chamber. An electrically isolated sample holder biased to +300 V to collect the secondary electrons, connected to a digital current integrator (model 439 by Ortec) to measure the incident beam current. A home made device has been used to store the real-time evolution of the beam current in a computer file allowing the correction of the IL yields due to the current fluctuations. The target holder is a rectangle of 150 × 112 mm2 and can be tilted. The X and Y movements are controlled through stepping motors, which permits a fine control of the beam spot positioning as well as the study of several samples without venting the chamber. A silica optical fiber of 1 mm diameter fixed to the vacuum chamber, which collects the light from the scintillators

  1. Time resolution of time-of-flight detector based on multiple scintillation counters readout by SiPMs

    CERN Document Server

    Cattaneo, P W; Gatti, F; Nishimura, M; Ootani, W; Rossella, M; Shirabe, S; Uchiyama, Y

    2015-01-01

    A new timing detector measuring ~50 MeV/c positrons is under development for the MEG II experiment, aiming at a time resolution $\\sigma_t \\sim 30~\\mathrm{ps}$. The resolution is expected to be achieved by measuring each positron time with multiple counters made of plastic scintillator readout by silicon photomultipliers (SiPMs). The purpose of this work is to demonstrate the time resolution for ~50 MeV/c positrons using prototype counters. Counters with dimensions of $90\\times 40\\times 5~\\mathrm{mm}^3$ readout by three SiPMs at each end were build with SiPMs from Hamamatsu Photonics and AdvanSiD and tested in a positron beam at the DA$\\Phi$NE Beam Test Facility. It was found that the time resolution improves nearly as the square root of the number of counter hits. A time resolution $\\sigma_t=26.2\\pm1.3~\\mathrm{ps}$ was obtained with eight counters with Hamamatsu SiPMs. These results suggest that the design resolution is achievable in the MEG II experiment.

  2. Zr and Ba edge phenomena in the scintillation intensity of fluorozirconate-based glass-ceramic X-ray detectors.

    Science.gov (United States)

    Henke, Bastian; Schweizer, Stefan; Johnson, Jacqueline A; Keane, Denis T

    2007-05-01

    The energy-dependent scintillation intensity of Eu-doped fluorozirconate glass-ceramic X-ray detectors has been investigated in the energy range from 10 to 40 keV. The experiments were performed at the Advanced Photon Source, Argonne National Laboratory, USA. The glass ceramics are based on Eu-doped fluorozirconate glasses, which were additionally doped with chlorine to initiate the nucleation of BaCl(2) nanocrystals therein. The X-ray excited scintillation is mainly due to the 5d-4f transition of Eu(2+) embedded in the BaCl(2) nanocrystals; Eu(2+) in the glass does not luminesce. Upon appropriate annealing the nanocrystals grow and undergo a phase transition from a hexagonal to an orthorhombic phase of BaCl(2). The scintillation intensity is investigated as a function of the X-ray energy, particle size and structure of the embedded nanocrystals. The scintillation intensity versus X-ray energy dependence shows that the intensity is inversely proportional to the photoelectric absorption of the material, i.e. the more photoelectric absorption the less scintillation. At 18 and 37.4 keV a significant decrease in the scintillation intensity can be observed; this energy corresponds to the K-edge of Zr and Ba, respectively. The glass matrix as well as the structure and size of the embedded nanocrystals have an influence on the scintillation properties of the glass ceramics.

  3. Reflectance measurements of PTFE, Kapton, and PEEK for xenon scintillation light for the LZ detector.

    Science.gov (United States)

    Arthurs, M.; Batista, E.; Haefner, J.; Lorenzon, W.; Morton, D.; Neff, A.; Okunawo, M.; Pushkin, K.; Sander, A.; Stephenson, S.; Wang, Y.; LZ Collaboration

    2017-01-01

    LZ (LUX-Zeplin) is an international collaboration that will look for dark matter candidates, WIMPs (Weakly Interacting Massive Particles), through direct detection by dual-phase time projection chamber (TPC) using liquid xenon. The LZ detector will be located nearly a mile underground at SURF, South Dakota, shielded from cosmic background radiation. Seven tons active mass of liquid xenon will be used for detecting the weak interaction of WIMPs with ordinary matter. Over three years of operation it is expected to reach the ultimate sensitivity of 2x10-48 cm2 for a WIMP mass of 50 GeV. As for many other rare event searches, high light collection efficiency is essential for LZ detector. Moreover, in order to achieve greater active volume for detection as well as reduce potential backgrounds, thinner detector walls without significant loss in reflectance are desired. Reflectance measurements of polytetrafluoroethylene (PTFE), Kapton, and PEEK for xenon scintillation light (178 nm), conducted at the University of Michigan using the Michigan Xenon Detector (MiX) will be presented. The University of Michigan, LZ Collaboration, The US Department of Energy.

  4. High-position-resolution scintillation neutron-imaging detector by crossed-fiber readout with novel centroid-finding method

    CERN Document Server

    Katagiri, M; Sakasai, K; Matsubayashi, M; Birumachi, A; Takahashi, H; Nakazawa, M

    2002-01-01

    Aiming at high-position-resolution and high-counting-rate neutron imaging, a novel centroid-finding method is proposed for a scintillation neutron-imaging detector with crossed-fiber readout. Crossed wavelength-shifting fibers are arranged on and under the scintillator. Luminescences generated in the scintillator are emitted and detected by a few fibers surrounding the incident point of a neutron. In the novel method, X and Y positions of the incident neutron are decided by coincidence of a central signal and neighboring signals, respectively. By fundamental experiments using a ZnS:Ag/ sup 6 LiF scintillator of 0.5-mm thickness and crossed wavelength-shifting fibers with a size of 0.5 x 0.5 mm sup 2 , it was confirmed that the position resolution is about 0.5 mm and the limitation of the neutron-counting rate is 320 kcps. (orig.)

  5. HZE dosimetry in space using plastic track detectors

    CERN Document Server

    Kopp, J; Reitz, G; Enge, W

    1999-01-01

    Plastic nuclear track detectors were used to measure the contribution of High charge Z and energy E (HZE) particles to the radiation exposure of manned space missions. Results from numerous space missions in the orbit planned for the International Space Station are compared. The measurements cover the declining phase of the last solar cycle during the past 7 years and various shielding conditions inside the US Space Shuttle and the Russian MIR-station.

  6. A PET detector prototype based on digital SiPMs and GAGG scintillators.

    Science.gov (United States)

    Schneider, Florian R; Shimazoe, Kenji; Somlai-Schweiger, Ian; Ziegler, Sibylle I

    2015-02-21

    Silicon Photomultipliers (SiPM) are interesting light sensors for Positron Emission Tomography (PET). The detector signal of analog SiPMs is the total charge of all fired cells. Energy and time information have to be determined with dedicated readout electronics. Philips Digital Photon Counting has developed a SiPM with added electronics on cell level delivering a digital value of the time stamp and number of fired cells. These so called Digital Photon Counters (DPC) are fully digital devices. In this study, the feasibility of using DPCs in combination with LYSO (Lutetium Yttrium Oxyorthosilicate) and GAGG (Gadolinium Aluminum Gallium Garnet) scintillators for PET is tested. Each DPC module has 64 channels with 3.2 × 3.8775 mm(2), comprising 3200 cells each. GAGG is a recently developed scintillator (Zeff = 54, 6.63 g cm(-3), 520 nm peak emission, 46 000 photons MeV(-1), 88 ns (92%) and 230 ns (8%) decay times, non-hygroscopic, chemically and mechanically stable). Individual crystals of 2 × 2 × 6 mm(3) were coupled onto each DPC pixel. LYSO coupled to the DPC results in a coincidence time resolution (CTR) of 171 ps FWHM and an energy resolution of 12.6% FWHM at 511 keV. Using GAGG, coincidence timing is 310 ps FWHM and energy resolution is 8.5% FWHM. A PET detector prototype with 2 DPCs equipped with a GAGG array matching the pixel size (3.2 × 3.8775 × 8 mm(3)) was assembled. To emulate a ring of 10 modules, objects are rotated in the field of view. CTR of the PET is 619 ps and energy resolution is 9.2% FWHM. The iterative MLEM reconstruction is based on system matrices calculated with an analytical detector response function model. A phantom with rods of different diameters filled with (18)F was used for tomographic tests.

  7. A PET detector prototype based on digital SiPMs and GAGG scintillators

    Science.gov (United States)

    Schneider, Florian R.; Shimazoe, Kenji; Somlai-Schweiger, Ian; Ziegler, Sibylle I.

    2015-02-01

    Silicon Photomultipliers (SiPM) are interesting light sensors for Positron Emission Tomography (PET). The detector signal of analog SiPMs is the total charge of all fired cells. Energy and time information have to be determined with dedicated readout electronics. Philips Digital Photon Counting has developed a SiPM with added electronics on cell level delivering a digital value of the time stamp and number of fired cells. These so called Digital Photon Counters (DPC) are fully digital devices. In this study, the feasibility of using DPCs in combination with LYSO (Lutetium Yttrium Oxyorthosilicate) and GAGG (Gadolinium Aluminum Gallium Garnet) scintillators for PET is tested. Each DPC module has 64 channels with 3.2 × 3.8775 mm2, comprising 3200 cells each. GAGG is a recently developed scintillator (Zeff = 54, 6.63 g cm-3, 520 nm peak emission, 46 000 photons MeV-1, 88 ns (92%) and 230 ns (8%) decay times, non-hygroscopic, chemically and mechanically stable). Individual crystals of 2 × 2 × 6 mm3 were coupled onto each DPC pixel. LYSO coupled to the DPC results in a coincidence time resolution (CTR) of 171 ps FWHM and an energy resolution of 12.6% FWHM at 511 keV. Using GAGG, coincidence timing is 310 ps FWHM and energy resolution is 8.5% FWHM. A PET detector prototype with 2 DPCs equipped with a GAGG array matching the pixel size (3.2 × 3.8775 × 8 mm3) was assembled. To emulate a ring of 10 modules, objects are rotated in the field of view. CTR of the PET is 619 ps and energy resolution is 9.2% FWHM. The iterative MLEM reconstruction is based on system matrices calculated with an analytical detector response function model. A phantom with rods of different diameters filled with 18F was used for tomographic tests.

  8. Scintillator counters with multi-pixel avalanche photodiode readout for the ND280 detector of the T2K experiment

    Energy Technology Data Exchange (ETDEWEB)

    Mineev, O. [Institute for Nuclear Research of RAS, INR RAS, 60th October Revolution Pr. 7a, 117312 Moscow (Russian Federation)]. E-mail: oleg@inr.ru; Afanasjev, A. [Institute for Nuclear Research of RAS, INR RAS, 60th October Revolution Pr. 7a, 117312 Moscow (Russian Federation); Bondarenko, G.; Golovin, V. [Center of Perspective Technology and Apparatus, 107076 Moscow (Russian Federation); Gushchin, E.; Izmailov, A.; Khabibullin, M.; Khotjantsev, A. [Institute for Nuclear Research of RAS, INR RAS, 60th October Revolution Pr. 7a, 117312 Moscow (Russian Federation); Kudenko, Yu. [Institute for Nuclear Research of RAS, INR RAS, 60th October Revolution Pr. 7a, 117312 Moscow (Russian Federation); Kurimoto, Y. [Department of Physics, Kyoto University, Kyoto 606-8502 (Japan); Kutter, T. [Department of Physics and Astronomy, Louisiana State University, Baton Rouge, Louisiana 70803-4001 (United States); Lubsandorzhiev, B. [Institute for Nuclear Research of RAS, INR RAS, 60th October Revolution Pr. 7a, 117312 Moscow (Russian Federation); Mayatski, V. [AO Uniplast, 600016 Vladimir (Russian Federation); Musienko, Yu. [Institute for Nuclear Research of RAS, INR RAS, 60th October Revolution Pr. 7a, 117312 Moscow (Russian Federation); Nakaya, T.; Nobuhara, T. [Department of Physics, Kyoto University, Kyoto 606-8502 (Japan); Shaibonov, B.A.J.; Shaikhiev, A. [Institute for Nuclear Research of RAS, INR RAS, 60th October Revolution Pr. 7a, 117312 Moscow (Russian Federation); Taguchi, M. [Department of Physics, Kyoto University, Kyoto 606-8502 (Japan); Yershov, N. [Institute for Nuclear Research of RAS, INR RAS, 60th October Revolution Pr. 7a, 117312 Moscow (Russian Federation); Yokoyama, M. [Department of Physics, Kyoto University, Kyoto 606-8502 (Japan)

    2007-07-11

    The Tokai-to-Kamioka (T2K) experiment is a second generation long baseline neutrino oscillation experiment which aims at a sensitive search for {nu}{sub e} appearance. The main design features of the T2K near neutrino detectors located at 280m from the target are presented, and the scintillator counters are described. The counters are readout via WLS fibers embedded into S-shaped grooves in the scintillator from both ends by multi-pixel avalanche photodiodes operating in a limited Geiger mode. Operating principles and results of tests of photosensors with a sensitive area of 1mm{sup 2} are presented. A time resolution of 1.75ns, a spatial resolution of 9.9-12.4cm, and a detection efficiency for minimum ionizing particles of more than 99% were obtained for scintillator detectors in a beam test.

  9. Patient-specific quality assurance for spot scanning proton beams using a large-volume liquid scintillator detector

    Science.gov (United States)

    Robertson, D.; Beddar, S.

    2017-05-01

    A large-volume liquid scintillator detector was used to measure individual energy layers from a clinical prostate treatment plan on a scanning proton beam system. Lateral and beam’s-eye view images of the dose distribution were acquired with two CCD cameras facing adjacent sides of a scintillator tank. The measured dose images were compared with calculated dose distributions from a validated Monte Carlo model. The measured and calculated dose distributions showed good agreement, with the exception of the Bragg peak region of the lateral view, which exhibited ionization quenching. The beam’s-eye and lateral views achieved gamma analysis passing rates of 99.7% and 92.5%, respectively, using gamma criteria of 3%, 3 mm. Large-volume scintillator detectors show promise for quick and accurate measurements of patient treatment fields for scanning proton beam systems.

  10. Scintillator-Lucite sandwich detector for n/gamma separation in the GeV energy region

    CERN Document Server

    Watanabe, H; Harada, E; Inoue, S; Inagaki, T; Kobayashi, S; Kurilin, A S; Lim, G Y; Ogawa, I; Okuno, H; Omata, K; Sato, T; Shinkawa, T; Tsamalaidze, Z; Tsukamoto, T; Yoshimura, Y

    2002-01-01

    A Scintillator-Lucite Sandwich Detector (SLSD) has been developed for n/gamma separation in the GeV energy region. An efficient n/gamma separation is achieved by measuring a correlation between the scintillation and Cherenkov light yields. The basic performance of the detector has been tested with e, pi and p beams with momenta between 0.5 and 2.0 GeV/c; the results were compared with a Monte-Carlo simulation. The n/gamma separation capability of this detector has been studied by simulations in the energy range from 5 MeV to 12 GeV. The SLSD detector was successfully used for a beam survey of the new K sub L sup 0 beam line built for a K sub L sup 0-> pi sup 0 nu nu-bar experiment at the KEK 12-GeV proton synchrotron.

  11. Response function study of a scintillator detector of NaI(Tl); Estudo da funcao resposta de um detector cintilador de NaI(Tl)

    Energy Technology Data Exchange (ETDEWEB)

    Villa, Marcelo Barros; Costa, Alessandro Martins da, E-mail: amcosta@usp.br [Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Dept. de Fisica

    2014-07-01

    In measurements of gamma rays with Nai (Tl) scintillator, the detectors output data are pulse height spectra, that corresponding to distorted information about the radiation source due to various errors associated with the crystal scintillation process and electronics associated, instead of power spectra photons. Pulse height spectra are related to the real power spectra by means of scintillator detector response function NaI (Tl). In this work, the response function for a cylindrical crystal of Nal (Tl) of 7,62 x 7,62 cm (diameter x length) was studied, by Monte Carlo method, using the EGSnrc tool to model the transport of radiation, combined with experimental measurements. An inverse response matrix, even with the energy of the square root, which transforms the pulse height spectrum of photon energy spectrum was obtained. The results of this transformation of pulse height spectrum for photon energy spectrum is presented, showing that the methodology employed in this study is suitable.

  12. Extension of dynamic range in X-ray radiography using multi-color scintillation detector

    CERN Document Server

    Nittoh, K; Sakurai, T; Yoshida, T; Mochiki, K I

    2003-01-01

    A new imaging system using the multi-color scintillator Gd sub 2 O sub 2 S:Eu has been developed for the X-ray radiography. In this method a color Charge Coupled Device detects the weak blue and green photons associated with the transitions from the terms like sup 5 D sub 1 and sup 5 D sub 2 in the Eu-ions as well as the dominant red photons. As these transitions become appreciable and saturate at quite different intensity levels of the X-ray, we can realize a big extension of the dynamic range of the imaging almost by hundred times in comparison with the conventional monochromatic method. As a result, the new system makes it possible to take a clear image of any complex object, which consists of various parts of the different X-ray penetrability, from plastic to heavy metal, at a single shot.

  13. A Comprehensive Model to Predict the Timing Resolution of SiPM-Based Scintillation Detectors : Theory and Experimental Validation

    NARCIS (Netherlands)

    Seifert, Stefan; van Dam, Herman T.; Vinke, Ruud; Dendooven, Peter; Lohner, Herbert; Beekman, Freek J.; Schaart, Dennis R.

    Silicon photomultipliers (SiPMs) are expected to replace photomultiplier tubes (PMTs) in several applications that require scintillation detectors with excellent timing resolution, such as time-of-flight positron emission tomography (TOF-PET). However, the theory about the timing resolution of

  14. Experimental Validation of an Efficient Fan-Beam Calibration Procedure for k -Nearest Neighbor Position Estimation in Monolithic Scintillator Detectors

    NARCIS (Netherlands)

    Borghi, G.; Tabacchini, V.; Seifert, S.; Schaart, D.R.

    2015-01-01

    Monolithic scintillator detectors can achieve excellent spatial resolution and coincidence resolving time. However, their practical use for positron emission tomography (PET) and other applications in the medical imaging field is still limited due to drawbacks of the different methods used to

  15. A quantitative PGNAA study for use in aqueous solution measurements using Am–Be neutron source and BGO scintillation detector

    Energy Technology Data Exchange (ETDEWEB)

    Ghal-Eh, N., E-mail: ghal-eh@du.ac.ir [School of Physics, Damghan University, P.O. Box 36716-41167, Damghan (Iran, Islamic Republic of); Ahmadi, P. [School of Physics, Damghan University, P.O. Box 36716-41167, Damghan (Iran, Islamic Republic of); Doost-Mohammadi, V. [Nuclear Science and Technology Research Center, AEOI, P.O. Box 11365-8486, Tehran (Iran, Islamic Republic of)

    2016-02-01

    A prompt gamma neutron activation analysis (PGNAA) system including an Am–Be neutron source and BGO scintillation detector are used for quantitative analysis of bulk samples. Both Monte Carlo-simulated and experimental data are considered as input data libraries for two different procedures based on neural network and least squares methods. The results confirm the feasibility and precision of the proposed methods.

  16. A Comprehensive Model to Predict the Timing Resolution of SiPM-Based Scintillation Detectors : Theory and Experimental Validation

    NARCIS (Netherlands)

    Seifert, Stefan; van Dam, Herman T.; Vinke, Ruud; Dendooven, Peter; Lohner, Herbert; Beekman, Freek J.; Schaart, Dennis R.

    2012-01-01

    Silicon photomultipliers (SiPMs) are expected to replace photomultiplier tubes (PMTs) in several applications that require scintillation detectors with excellent timing resolution, such as time-of-flight positron emission tomography (TOF-PET). However, the theory about the timing resolution of SiPM-

  17. Basic processes and scintillator and semiconductor detectors; Des processus de base aux detecteurs scintillateurs et semi-conducteurs

    Energy Technology Data Exchange (ETDEWEB)

    Bourgeois, C. [Paris-11 Univ., 91 - Orsay (France). Inst. de Physique Nucleaire]|[Paris-7 Univ., 75 (France)

    1994-12-31

    In the following course, the interaction of heavy charged particles, electrons and {Gamma} with matter is represented. Two types of detectors are studied, organic and inorganic scintillators and semiconductors. The signal formation is analysed. (author). 13 refs., 48 figs., 5 tabs.

  18. Liquid Scintillation Detectors for Gamma and Neutron Diagnostic at Textor and Results of Runaway and Sawtooth Oscillations

    NARCIS (Netherlands)

    Hoenen, F.; Graffmann, E.; Finken, K.H.; Barrenscheen, H. J.; Klein, H.; R. Jaspers,

    1994-01-01

    Time and energy resolved neutron and gamma measurements are performed at the TEXTOR tokamak with a fast liquid NE-213 scintillator. To distinguish between neutron and gamma (gamma)-ray induced events, pulse shape discrimination is used. To suppress scattered radiation, the detector is installed in w

  19. Used fuel storage monitoring using novel 4He scintillation fast neutron detectors and neutron energy discrimination analysis

    Science.gov (United States)

    Kelley, Ryan P.

    With an increasing quantity of spent nuclear fuel being stored at power plants across the United States, the demand exists for a new method of cask monitoring. Certifying these casks for transportation and long-term storage is a unique dilemma: their sealed nature lends added security, but at the cost of requiring non-invasive measurement techniques to verify their contents. This research will design and develop a new method of passively scanning spent fuel casks using 4He scintillation detectors to make this process more accurate. 4He detectors are a relatively new technological development whose full capabilities have not yet been exploited. These detectors take advantage of the high 4He cross section for elastic scattering at fast neutron energies, particularly the resonance around 1 MeV. If one of these elastic scattering interactions occurs within the detector, the 4He nucleus takes energy from the incident neutron, then de-excites by scintillation. Photomultiplier Tubes (PMTs) at either end of the detector tube convert this emitted light into an electrical signal. The goal of this research is to use the neutron spectroscopy features of 4He scintillation detectors to maintain accountability of spent fuel in storage. This project will support spent fuel safeguards and the detection of fissile material, in order to minimize the risk of nuclear proliferation and terrorism.

  20. Production and quality assurance of a Scintillating Fibre detector for the LHCb experiment

    Science.gov (United States)

    Nieswand, S.

    2017-02-01

    To deal with the instantaneous luminosity of the LHC after the Long Shutdown 2 in 2018/19, several subsystems of the LHCb detector have to be exchanged or upgraded. For this purpose, the Scintillating Fibre (SciFi) Tracker is being built to replace the current downstream tracking system. The base of this new tracker are 2.5m long scintillating fibres (varnothing 250µm) in which light is generated by passing charged particles. The fibres are arranged in six-layer fibre mats which are read out with the help of silicon photomultipliers (SiPMs) at the edge of the tracker's acceptance. The tracker will cover an area larger than 340m2. To produce the required total of 1024 fibre mats, serial production was set up at several production sites. To assure the quality of the fibre mats, they are subject to various tests during the production. The different production steps as well as the quality assurance measurements will be presented.

  1. Microstructured boron foil scintillating G-GEM detector for neutron imaging

    Science.gov (United States)

    Fujiwara, Takeshi; Bautista, Unico; Mitsuya, Yuki; Takahashi, Hiroyuki; Yamada, Norifumi L.; Otake, Yoshie; Taketani, Atsushi; Uesaka, Mitsuru; Toyokawa, Hiroyuki

    2016-12-01

    In this study, a new simple neutron imaging gaseous detector was successfully developed by combining a micro-structured 10B foil, a glass gas electron multiplier (G-GEM), and a mirror-lens-charge-coupled device (CCD)-camera system. The neutron imaging system consists of a chamber filled with Ar/CF4 scintillating gas mixture. Inside this system, the G-GEM is mounted for gas multiplication. The neutron detection in this system is based on the reaction between 10B and neutrons. A micro-structured 10B is developed to overcome the issue of low detection efficiency. Secondary electrons excite Ar/CF4 gas molecules, and high-yield visible photons are emitted from those excited gas molecules during the gas electron multiplication process in the G-GEM holes. These photons are easily detected by a mirror-lens-CCD-camera system. A neutron radiograph is then simply formed. We obtain the neutron images of different materials with a compact accelerator-driven neutron source. We confirm that the new scintillating G-GEM-based neutron imager works properly with low gamma ray sensitivity and exhibits a good performance as a new simple digital neutron imaging device.

  2. Sci—Sat AM: Stereo — 07: Suitability of a plastic scintillator dosimeter for composite clinical fields delivered using the Cyberknife robotic radiosurgery system

    Energy Technology Data Exchange (ETDEWEB)

    Vandervoort, E.; Szanto, J. [The Ottawa Hospital Cancer Centre (Canada); Christiansen, E. [The Ottawa Hospital Cancer Centre (Canada); Department of Physics, McGill University (Canada)

    2014-08-15

    Plastic scintillation dosimeters (PSDs) have favourable characteristics for small and composite field dosimetry in radiosurgery, however, imperfect corrections for the Cerenkov radiation contamination could limit their accuracy for complex deliveries. In this work, we characterize the dose and dose-rate linearity, directional dependence, and compare output factors with other stereotactic detectors for a new commercially available PSD (Exradin W1). We provide some preliminary comparisons of planned and measured dose for composite fields delivered clinically by a Cyberknife radiosurgery system. The W1 detector shows good linearity with dose (<0.5%) and dose rate (<0.8%) relative to the signal obtained using an ion chamber under the same conditions. A maximum difference of 2% was observed depending on the detector's angular orientation. Output factors for all detectors agree within a range of ±3.2% and ±1.5% for the 5 and 7.5 mm collimators, respectively, provided Monte-Carlo corrections for detector effects are applied to diode and ion chambers (without corrections the range is ±5.5% and ±3.1% for these two collimators). For clinical beam deliveries using 5 and 7.5 mm collimators, four of the six patients showed better agreement with planned dose for the PSD detector compared to a micro ion chamber. Two of the six patients investigated, however, showed 5% differences between PSD and planned dose, film measurements and the ratio of PSD and micro ion chamber signal suggest that further investigation is warranted for these plans. The W1 detector is a promising tool for stereotactic plan verification under the challenging dosimetric conditions of stereotactic radiosurgery.

  3. The Front-End electronics for the LHCb scintillating fibres detector

    CERN Document Server

    Chanal, Hervé; Pillet, Nicolas

    2014-01-01

    The LHCb detector will be upgraded during the next LHC shutdown in 2018/19 [ 1 ]. The tracker system will have a major overhaul. Its components will be replaced with new technologies in order to cope with the increased hit occupancy and radiation environment. A detector made of scintillating fibres read out by silicon photomultipliers (SiPM) is studied for this upgrade. Even if this technology has proven to achieve high efficiency and spatial resolution, its integration within a LHC experiment bears new challenges. This detector will consist of 12 planes of 5 to 6 layers of 250 m m fibres with an area of 5 6 m 2 . It leads to a total of 500k SiPM channels which need to be read out at 40 MHz. This article gives an overview of the R&D; status of the readout board and the PACIFIC chip. The readout board is connected to the SiPM on one side and to the experiment data-acquisition, experimental control system and services on the other side. The PACIFIC chip is a 128-channels ASIC which can be connected to one 1...

  4. LHCb: The Front-End electronics for the LHCb scintillating fibres detector

    CERN Multimedia

    Chanal, H; Pillet, N

    2014-01-01

    The LHCb detector will be upgraded during the next LHC shutdown in 2018/19. The tracker system will have a major overhaul. Its components will be replaced with new technologies in order to cope with the increased hit occupancy and radiation environment. A detector made of scintillating fibres read out by silicon photomultipliers (SiPM) is studied for this upgrade. Even if this technology has proven to achieve high efficiency and spatial resolution, its integration within a LHC experiment bears new challenges. This detector will consist of 12 planes of 5 to 6 layers of 250 $\\mu$m fibres with an area of 5×6 m$^2$. Its lead to a total of 500k SiPM channels which need to will be read out at 40MHz. This talk gives an overview of the R&D status of the readout board and the PACIFIC chip. The readout board is connected to the SiPM on one side and to the experiment data-acquisition, experimental control system and services on the other side . The PACIFIC chip is a 128 channel ASIC which can be connected to one 12...

  5. A practical method for depth of interaction determination in monolithic scintillator PET detectors

    Energy Technology Data Exchange (ETDEWEB)

    Van Dam, Herman T; Seifert, Stefan; Beekman, Freek J; Schaart, Dennis R [Delft University of Technology, Radiation Detection and Medical Imaging, Mekelweg 15, 2629 JB Delft (Netherlands); Vinke, Ruud; Dendooven, Peter; Loehner, Herbert, E-mail: h.t.vandam@tudelft.nl [Kernfysisch Versneller Instituut, University of Groningen, Zernikelaan 25, 9747 AA Groningen (Netherlands)

    2011-07-07

    Several new methods for determining the depth of interaction (DOI) of annihilation photons in monolithic scintillator detectors with single-sided, multi-pixel readout are investigated. The aim is to develop a DOI decoding method that allows for practical implementation in a positron emission tomography system. Specifically, calibration data, obtained with perpendicularly incident gamma photons only, are being used. Furthermore, neither detector modifications nor a priori knowledge of the light transport and/or signal variances is required. For this purpose, a clustering approach is utilized in combination with different parameters correlated with the DOI, such as the degree of similarity to a set of reference light distributions, the measured intensity on the sensor pixel(s) closest to the interaction position and the peak intensity of the measured light distribution. The proposed methods were tested experimentally on a detector comprised of a 20 mm x 20 mm x 12 mm polished LYSO:Ce crystal coupled to a 4 x 4 multi-anode photomultiplier. The method based on the linearly interpolated measured intensities on the sensor pixels closest to the estimated (x, y)-coordinate outperformed the other methods, yielding DOI resolutions between {approx}1 and {approx}4.5 mm FWHM depending on the DOI, the (x, y) resolution and the amount of reference data used.

  6. Optimization of the NSCL Digital Data Acquisition System For Use With Fast Scintillator Detectors

    Science.gov (United States)

    Prokop, Christopher; Liddick, Sean; Larson, Nicole; Suchyta, Scott; Tompkins, Jeromy

    2013-10-01

    The Digital Data Acquisition System (DDAS) at the National Superconducting Cyclotron Laboratory is composed of several XIA Pixie-16 modules utilizing 12-bit digitizers sampling at 100 Mega-Samples-Per-Second. DDAS has been applied to fast organic and inorganic scintillator detectors intended for level lifetime and neutron time-of-flight studies, for which the time resolution is critical. Simultaneous high-resolution time and energy determination using online digital CFD and trapezoidal filtering algorithms is non-intuitive due to the short characteristic rise and decay times of the signals with respect to the sampling time of the digitizers. A new technique has been developed to identify the optimum filter parameters to maximize the time and energy resolution of each detector signal in an offline analysis. The parameters were subsequently verified online and have resulted in a 30% improvement in the measured time resolution between two LaBr3 detectors. Additional results and applications of the technique will be presented.

  7. Novel Wavelength Shifting Collection Systems for Vacuum Ultraviolet Scintillation Photons in in Noble Gas Detectors

    Science.gov (United States)

    Gehman, Victor

    2013-04-01

    Detection of vacuum ultraviolet (VUV) photons presents a challenge because this band of the electromagnetic spectrum has a short enough wavelength to scatter off of most (though not all) materials, but is not energetic enough to penetrate into the bulk of a detector (so cannot be treated calorimetrically like x rays or γ rays). This is exactly the band in which noble gasses (which make excellent media for radiation detectors) scintillate. VUV photon detection usually involves shifting them to visible wavelengths with a fluorescent molecule deposited on an optically clear surface viewed by a photosensor. Such techniques, while comparatively efficient and simple to fabricate, have high cost and complexity per unit coverage area making them prohibitively expensive and complicated to scale up to the very large sizes necessary for the next generation of neutrino, dark matter, and other rare event search experiments. We present several lines of inquiry attempting to address this problem, focusing on solutions that are directly applicable to a variety of current or next generation noble gas detectors. This line of R&D is a potentially fruitful avenue capable of furthering the goals of many experiments with a broad portfolio of fundamental and applied research.

  8. Measurement of loss of DT fusion products using scintillator detectors in TFTR

    Energy Technology Data Exchange (ETDEWEB)

    Darrow, D.S.; Herrmann, H.W.; Johnson, D.W.; Marsala, R.J.; Palladino, R.W.; Zweben, S.J. [Princeton Univ., NJ (United States). Plasma Physics Lab.; Tuszewski, M. [Los Alamos National Lab., NM (United States)

    1995-03-01

    A poloidal array of MeV ion loss probes previously used to measure DD fusion product loss has been upgraded to measure the loss of alpha particles from DT plasmas in TFTR. The following improvements to the system have been made in preparation for the use of tritium in TFTR: (1) relocation of detectors to a neutronshielded enclosure in the basement to reduce neutron-induced background signals; (2) replacement of ZnS:Cu (P31) scintillators in the probes with the Y{sub 3}Al{sub 5}0{sub 12}:Ce(P46) variety to minimize damage and assure linearity at the fluxes anticipated from DT plasmas; and (3) shielding of the fiber optic bundles which carry the fight from the probes to the detectors to reduce neutron- and gamma-induced light within them. In addition to the above preparations, the probes have been absolutely calibrated for alpha particles by using the Van de Graaf accelerator at Los Alamos National Laboratory. Alpha particle losses from DT plasmas have been observed, and losses at the detector 901 below the midplane are consistent with first orbit loss.

  9. Time and position sensitive single photon detector for scintillator read-out

    Science.gov (United States)

    Schössler, S.; Bromberger, B.; Brandis, M.; Schmidt, L. Ph H.; Tittelmeier, K.; Czasch, A.; Dangendorf, V.; Jagutzki, O.

    2012-02-01

    We have developed a photon counting detector system for combined neutron and γ radiography which can determine position, time and intensity of a secondary photon flash created by a high-energy particle or photon within a scintillator screen. The system is based on a micro-channel plate photomultiplier concept utilizing image charge coupling to a position- and time-sensitive read-out anode placed outside the vacuum tube in air, aided by a standard photomultiplier and very fast pulse-height analyzing electronics. Due to the low dead time of all system components it can cope with the high throughput demands of a proposed combined fast neutron and dual discrete energy γ radiography method (FNDDER). We show tests with different types of delay-line read-out anodes and present a novel pulse-height-to-time converter circuit with its potential to discriminate γ energies for the projected FNDDER devices for an automated cargo container inspection system (ACCIS).

  10. Measurements on semiconductor and scintillator detectors at the Advanced Light Source (Conference Presentation)

    Science.gov (United States)

    Camarda, Giuseppe S.; Bolotnikov, Aleksey E.; Cui, Yonggang; Gul, Rubi; Hossain, Anwar; Roy, Utpal N.; Yang, Ge; James, Ralph B.; Vanier, Peter E.

    2016-09-01

    During the transition period between closure of Beamline X27B at BNL's NSLS and the opening of Beamline MID at NSLS-II, we began operation of LBNL's ALS Beamline 3.3.2 to carry out our radiation detection materials RD. Measurements performed at this Beamline include, X-ray Detector Response Mapping and White Beam X-ray Diffraction Topography (WBXDT), among others. We will introduce the capabilities of the Beamline and present the most recent results obtained on CdZnTe and scintillators. The goal of the studies on CdZnTe is to understand the origin and effects of subgrain boundaries and help to visualize the presence of a higher concentration of impurities, which might be responsible for the deterioration of the energy resolution and response uniformity in the vicinity of the sub-grain boundaries. The results obtained in the second year of measurements will be presented.

  11. Measurement-based characterization of multipixel avalanche photodiodes for scintillating detectors

    CERN Document Server

    Dziewiecki, M

    2012-01-01

    Multipixel avalanche photodiodes (MAPD) are recently gaining popularity in high energy physics experiments as an attractive replacement for photomultiplier tubes, which have been extensively used for many years as a part of various scintillating detectors. Their low price, small dimensions and another features facilitating their use (like mechanical shock resistance, magnetic field immunity or moderate supply voltage) make the MAPDs a good choice for commercial use as well, what is reflected in growing number of producers as well as MAPD models available on the market. This dissertation presents Author’s experience with MAPD measurements and modelling, gained during his work on the T2K (Tokai-to-Kamioka) long-baseline neutrino experiment, carried out by an international collaboration in Japan. First, operation principle of the MAPD, definitions of various parameters and measurement methods are discussed. Then, a device for large-scale MAPD measurements and related data processing methods are described. Fina...

  12. ecCNO solar neutrinos: A challenge for gigantic ultra-pure liquid scintillator detectors

    Science.gov (United States)

    Villante, F. L.

    2015-03-01

    Neutrinos produced in the Sun by electron capture reactions on 13N, 15O and 17F, to which we refer as ecCNO neutrinos, are not usually considered in solar neutrino analysis since the expected fluxes are extremely low. The experimental determination of this sub-dominant component of the solar neutrino flux is very difficult but could be rewarding since it provides a determination of the metallic content of the solar core and, moreover, probes the solar neutrino survival probability in the transition region at Eν ∼ 2.5 MeV. In this Letter, we suggest that this difficult measure could be at reach for future gigantic ultra-pure liquid scintillator detectors, such as LENA.

  13. Borexino A real time liquid scintillator detector for low energy solar neutrino study

    CERN Document Server

    Miramonti, L

    2002-01-01

    Borexino is a large unsegmented calorimeter featuring 300 tons of liquid scintillator, contained in a 8.5 meter nylon vessel, viewed by 2200 PMTs. The main goal of Borexino is the study, in real time, of low energy solar neutrinos, and in particular, the monoenergetic neutrinos coming from $^7Be$, which is one of the missing links on the solar neutrino problem. The achievement of high radiopurity level, in the order of $10^{-16} g/g$ of U/Th equivalent, necessary to the detection of the low energy component of the solar neutrino flux, was proved in the Borexino prototype: the Counting Test Facility. The detector is located underground in the Laboratori Nazionali del Gran Sasso in the center of Italy at 3500 meter water equivalent depth. In this paper the science and technology of Borexino are reviewed and its main capabilities are presented.

  14. Time and position sensitive single photon detector for scintillator read-out

    CERN Document Server

    Schössler, Sven; Brandis, Michal; Schmidt, Lothar Ph H; Tittelmeier, Kai; Czasch, Achim; Dangendorf, Volker; Jagutzki, Ottmar

    2012-01-01

    We have developed a photon counting detector system for combined neutron and gamma radiography which can determine position, time and intensity of a secondary photon flash created by a high-energy particle or photon within a scintillator screen. The system is based on a micro-channel plate photomultiplier concept utilizing image charge coupling to a position- and time-sensitive read-out anode placed outside the vacuum tube in air, aided by a standard photomultiplier and very fast pulse-height analyzing electronics. Due to the low dead time of all system components it can cope with the high throughput demands of a proposed combined fast neutron and dual discrete energy gamma radiography method (FNDDER). We show tests with different types of delay-line read-out anodes and present a novel pulse-height-to-time converter circuit with its potential to discriminate gamma energies for the projected FNDDER devices for an automated cargo container inspection system (ACCIS).

  15. ecCNO solar neutrinos: A challenge for gigantic ultra-pure liquid scintillator detectors

    Directory of Open Access Journals (Sweden)

    F.L. Villante

    2015-03-01

    Full Text Available Neutrinos produced in the Sun by electron capture reactions on 13N, 15O and 17F, to which we refer as ecCNO neutrinos, are not usually considered in solar neutrino analysis since the expected fluxes are extremely low. The experimental determination of this sub-dominant component of the solar neutrino flux is very difficult but could be rewarding since it provides a determination of the metallic content of the solar core and, moreover, probes the solar neutrino survival probability in the transition region at Eν∼2.5 MeV. In this Letter, we suggest that this difficult measure could be at reach for future gigantic ultra-pure liquid scintillator detectors, such as LENA.

  16. GEANT4 simulation of plastic scintillator strips with embedded optical fibers for a prototype of tomographic system

    Energy Technology Data Exchange (ETDEWEB)

    Riggi, S., E-mail: simone.riggi@ct.infn.i [Department of Physics and Astronomy, University of Catania (Italy); INFN Section of Catania (Italy); Centro Siciliano di Fisica Nucleare e Struttura della Materia (Italy); La Rocca, P. [Department of Physics and Astronomy, University of Catania (Italy); INFN Section of Catania (Italy); Museo Storico della Fisica e Centro Studi e Ricerche ' E. Fermi' , Roma (Italy); Leonora, E.; Lo Presti, D. [Department of Physics and Astronomy, University of Catania (Italy); INFN Section of Catania (Italy); Pappalardo, G.S. [INFN Section of Catania (Italy); Riggi, F.; Russo, G.V. [Department of Physics and Astronomy, University of Catania (Italy); INFN Section of Catania (Italy)

    2010-12-21

    The response to cosmic muons of plastic scintillator strips, with and without wavelength shifter fibers embedded, read out at both edges by photomultipliers has been studied through detailed GEANT4 simulations, with the aim of studying the light collection at the module ends under different conditions. The performed simulations, validated and tuned with data coming from a module prototype, could serve as an important guide for the design of a tomographic system based on cosmic ray muons.

  17. Pulse shape discrimination between (fast or thermal) neutrons and gamma rays with plastic scintillators: State of the art

    Energy Technology Data Exchange (ETDEWEB)

    Bertrand, Guillaume H.V. [CEA, LIST, Laboratoire Capteurs & Architectures Électroniques, CEA Saclay, F-91191 Gif-sur-Yvette cedex (France); Hamel, Matthieu, E-mail: matthieu.hamel@cea.fr [CEA, LIST, Laboratoire Capteurs & Architectures Électroniques, CEA Saclay, F-91191 Gif-sur-Yvette cedex (France); Normand, Stéphane [CEA, DAM, Le Ponant, 25 rue Leblanc, F-75015 Paris (France); Sguerra, Fabien [CEA, LIST, Laboratoire Capteurs & Architectures Électroniques, CEA Saclay, F-91191 Gif-sur-Yvette cedex (France)

    2015-03-11

    We would like to present here with the eyes of the chemist the most recent developments of plastic scintillators (PS) for neutron detection. This review covers the period from 2000 to August 2014, and is fragmented in two main chapters. The first chapter deals with the chemical modifications for thermal neutron capture, whereas the second chapter presents the various strategies used to enhance the response to fast neutrons via pulse shape discrimination. For each chapter the theory is also explained.

  18. Development of neutron-monitor detector using liquid organic scintillator coupled with 6Li + ZnS(Ag) Sheet.

    Science.gov (United States)

    Sato, Tatsuhiko; Endo, Akira; Yamaguchi, Yasuhiro; Takahashi, Fumiaki

    2004-01-01

    A phoswitch-type detector has been developed for monitoring neutron doses in high-energy accelerator facilities. The detector is composed of a liquid organic scintillator (BC501A) coupled with ZnS(Ag) sheets doped with 6Li. The dose from neutrons with energies above 1 MeV is evaluated from the light output spectrum of the BC501A by applying the G-function, which relates the spectrum to the neutron dose directly. The dose from lower energy neutrons, on the other hand, is estimated from the number of scintillations emitted from the ZnS(Ag) sheets. Characteristics of the phoswitch-type detector were studied experimentally in some neutron fields. It was found from the experiments that the detector has an excellent property of pulse-shape discrimination between the scintillations of BC501A and the ZnS(Ag) sheets. The experimental results also indicate that the detector is capable of reproducing doses from thermal neutrons as well as neutrons with energies from one to several tens of megaelectronvolts (MeV).

  19. Imaging characterization of a new gamma ray detector based on CRY019 scintillation crystal for PET and SPECT applications

    Science.gov (United States)

    Polito, C.; Pani, R.; Trigila, C.; Cinti, M. N.; Fabbri, A.; Frantellizzi, V.; De Vincentis, G.; Pellegrini, R.; Pani, R.

    2017-02-01

    In the last 40 years, in the field of Molecular Medicine imaging there has been a huge growth in the employment and in the improvement of detectors for PET and SPECT applications in order to reach accurate diagnosis of the diseases. The most important feature required to these detectors is an high quality of images that is usually obtained benefitting from the development of a wide number of new scintillation crystals with high imaging performances. In this contest, features like high detection efficiency, short decay time, great spectral match with photodetectors, absence of afterglow and low costs are surely attractive. However, there are other factors playing an important role in the realization of high quality images such as energy and spatial resolutions, position linearity and contrast resolution. With the aim to realize an high performace gamma ray detector for PET and SPECT applications, this work is focused on the evaluation of the imaging characteristics of a recently developed scintillation crystal, CRY019.

  20. Robustness of plastic scintillation microspheres in the continuous measurement of different river waters.

    Science.gov (United States)

    Tarancón, A; Novella, O; Batlle, M; Pujadas, M; Cros, J; García, J F

    2016-08-01

    Plastic scintillation microspheres (PSm) represent one of the most promising options for monitoring alpha and beta radioactivity in river water. For that reason, a study of the stability of PSm packed into a cell against the continuous flow of river water with different degrees of turbidity was performed over a period of 100h. The results showed that the volume of the cell became stable after 15h of pumping and continued to be stable throughout the 100h of the experiment. During this period of time, the detection efficiency of the PSm, in terms of efficiency*volume, presented mean values of 0.75(3)% for (3)H and 272(11)% for (90)Sr/(90)Y. No dependence on flow time or river water type was observed. The background was also constant for 100h and for the different water types, although (222)Rn should be removed from the water beforehand to prevent its accumulation in the PSm. Since PSm did not present any degradation throughout the whole experiment, PSm can undoubtedly be used for monitoring radioactivity with low reagent consumption, low waste generation and low maintenance costs.

  1. Cosmic-muon intensity measurement and overburden estimation in a building at surface level and in an underground facility using two BC408 scintillation detectors coincidence counting system.

    Science.gov (United States)

    Zhang, Weihua; Ungar, Kurt; Liu, Chuanlei; Mailhot, Maverick

    2016-10-01

    A series of measurements have been recently conducted to determine the cosmic-muon intensities and attenuation factors at various indoor and underground locations for a gamma spectrometer. For this purpose, a digital coincidence spectrometer was developed by using two BC408 plastic scintillation detectors and an XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The results indicate that the overburden in the building at surface level absorbs a large part of cosmic ray protons while attenuating the cosmic-muon intensity by 20-50%. The underground facility has the largest overburden of 39 m water equivalent, where the cosmic-muon intensity is reduced by a factor of 6. The study provides a cosmic-muon intensity measurement and overburden assessment, which are important parameters for analysing the background of an HPGe counting system, or for comparing the background of similar systems. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Using LEDs to stimulate the recovery of radiation damage to plastic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Wetzel, J., E-mail: james-wetzel@uiowa.edu [The University of Iowa, Iowa City, IA (United States); Tiras, E. [The University of Iowa, Iowa City, IA (United States); Bilki, B. [The University of Iowa, Iowa City, IA (United States); Beykent University, Istanbul (Turkey); Onel, Y. [The University of Iowa, Iowa City, IA (United States); Winn, D. [Fairfield University, Fairfield, CT (United States)

    2017-03-15

    In this study, we consider using LEDs to stimulate the recovery of scintillators damaged from radiation in high radiation environments. We irradiated scintillating tiles of polyethylene naphthalate (PEN), Eljen brand EJ-260 (EJN), an overdoped EJ-260 (EJ2P), and a lab-produced elastomer scintillator (ES) composed of p-terphenyl (ptp) in epoxy. Two different high-dose irradiations took place, with PEN dosed to 100 kGy, and the others to 78 kGy. We found that the ‘blue’ scintillators (PEN and ES) recovered faster and maximally higher with LEDs than without. Conversely exposing the ‘green’ scintillators (EJ-260) to LED light had a nearly negligible effect on the recovery. We hypothesize that the ‘green’ scintillators require wavelengths that match their absorption and emission spectra for LED stimulated recovery.

  3. Study on the energy response to neutrons for a new scintillating-fiber-array neutron detector

    CERN Document Server

    Zhang Qi; Wang Qun; Xie Zhong Shen

    2003-01-01

    The energy response of a new scintillating-fiber-array neutron detector to neutrons in the energy range 0.01 MeV<=E sub n<=14 MeV was modeled by combining a simplified Monte Carlo model and the MCNP 4b code. In order to test the model and get the absolute sensitivity of the detector to neutrons, one experiment was carried out for 2.5 and 14 MeV neutrons from T(p,n) sup 3 He and T(d,n) sup 4 He reactions at the Neutron Generator Laboratory at the Institute of Modern Physics, the Chinese Academy of Science. The absolute neutron fluence was obtained with a relative standard uncertainty 4.5% or 2.0% by monitoring the associated protons or sup 4 He particles, respectively. Another experiment was carried out for 0.5, 1.0, 1.5, 2.0, 2.5 MeV neutrons from T(p,n) sup 3 He reaction, and for 3.28, 3.50, 4.83, 5.74 MeV neutrons from D(d,n) sup 3 He reaction on the Model 5SDH-2 accelerator at China Institute of Atomic Energy. The absolute neutron fluence was obtained with a relative standard uncertainty 5.0% by usin...

  4. The scintillating fiber focal plane detector for the use of Kaos as a double arm spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Ayerbe Gayoso, Carlos Antonio

    2012-05-25

    The upgrade of the Mainz Mikrotron (MAMI) electron accelerator facility in 2007 which raised the beam energy up to 1.5 GeV, gives the opportunity to study strangeness production channels through electromagnetic process. The Kaon Spectrometer (KAOS) managed by the A1 Collaboration, enables the efficient detection of the kaons associated with strangeness electroproduction. Used as a single arm spectrometer, it can be combined with the existing high-resolution spectrometers for exclusive measurements in the kinematic domain accessible to them. For studying hypernuclear production in the {sup A}Z(e,e'K{sup +}){sup A}{sub {lambda}}(Z-1) reaction, the detection of electrons at very forward angles is needed. Therefore, the use of KAOS as a double-arm spectrometer for detection of kaons and the electrons at the same time is mandatory. Thus, the electron arm should be provided with a new detector package, with high counting rate capability and high granularity for a good spatial resolution. To this end, a new state-of-the-art scintillating fiber hodoscope has been developed as an electron detector. The hodoscope is made of two planes with a total of 18432 scintillating double-clad fibers of 0.83 mm diameter. Each plane is formed by 72 modules. Each module is formed from a 60 slanted multi-layer bundle, where 4 fibers of a tilted column are connected to a common read out. The read-out is made with 32 channels of linear array multianode photomultipliers. Signal processing makes use of newly developed double-threshold discriminators. The discriminated signal is sent in parallel to dead-time free time-to-digital modules and to logic modules for triggering purposes. Two fiber modules were tested with a carbon beam at GSI, showing a time resolution of {proportional_to}220 ps (FWHM) and a position resolution of {proportional_to}270 {mu}m (FWHM) with a detection efficiency {epsilon}>99%. The characterization of the spectrometer arm has been achieved through simulations

  5. A fast, primary-interaction Monte Carlo methodology for determination of total efficiency of cylindrical scintillation gamma-ray detectors

    Directory of Open Access Journals (Sweden)

    Rehman Shakeel U.

    2009-01-01

    Full Text Available A primary-interaction based Monte Carlo algorithm has been developed for determination of the total efficiency of cylindrical scintillation g-ray detectors. This methodology has been implemented in a Matlab based computer program BPIMC. For point isotropic sources at axial locations with respect to the detector axis, excellent agreement has been found between the predictions of the BPIMC code with the corresponding results obtained by using hybrid Monte Carlo as well as by experimental measurements over a wide range of g-ray energy values. For off-axis located point sources, the comparison of the BPIMC predictions with the corresponding results obtained by direct calculations as well as by conventional Monte Carlo schemes shows good agreement validating the proposed algorithm. Using the BPIMC program, the energy dependent detector efficiency has been found to approach an asymptotic profile by increasing either thickness or diameter of scintillator while keeping the other fixed. The variation of energy dependent total efficiency of a 3'x3' NaI(Tl scintillator with axial distance has been studied using the BPIMC code. About two orders of magnitude change in detector efficiency has been observed for zero to 50 cm variation in the axial distance. For small values of axial separation, a similar large variation has also been observed in total efficiency for 137Cs as well as for 60Co sources by increasing the axial-offset from zero to 50 cm.

  6. Monte Carlo investigations of megavoltage cone-beam CT using thick, segmented scintillating detectors for soft tissue visualization.

    Science.gov (United States)

    Wang, Yi; Antonuk, Larry E; El-Mohri, Youcef; Zhao, Qihua; Sawant, Amit; Du, Hong

    2008-01-01

    Megavoltage cone-beam computed tomography (MV CBCT) is a highly promising technique for providing volumetric patient position information in the radiation treatment room. Such information has the potential to greatly assist in registering the patient to the planned treatment position, helping to ensure accurate delivery of the high energy therapy beam to the tumor volume while sparing the surrounding normal tissues. Presently, CBCT systems using conventional MV active matrix flat-panel imagers (AMFPIs), which are commonly used in portal imaging, require a relatively large amount of dose to create images that are clinically useful. This is due to the fact that the phosphor screen detector employed in conventional MV AMFPIs utilizes only approximately 2% of the incident radiation (for a 6 MV x-ray spectrum). Fortunately, thick segmented scintillating detectors can overcome this limitation, and the first prototype imager has demonstrated highly promising performance for projection imaging at low doses. It is therefore of definite interest to examine the potential performance of such thick, segmented scintillating detectors for MV CBCT. In this study, Monte Carlo simulations of radiation energy deposition were used to examine reconstructed images of cylindrical CT contrast phantoms, embedded with tissue-equivalent objects. The phantoms were scanned at 6 MV using segmented detectors having various design parameters (i.e., detector thickness as well as scintillator and septal wall materials). Due to constraints imposed by the nature of this study, the size of the phantoms was limited to approximately 6 cm. For such phantoms, the simulation results suggest that a 40 mm thick, segmented CsI detector with low density septal walls can delineate electron density differences of approximately 2.3% and 1.3% at doses of 1.54 and 3.08 cGy, respectively. In addition, it was found that segmented detectors with greater thickness, higher density scintillator material, or lower density

  7. Use of a large time-compensated scintillation detector in neutron time-of-flight measurements

    Science.gov (United States)

    Goodman, Charles D.

    1979-01-01

    A scintillator for neutron time-of-flight measurements is positioned at a desired angle with respect to the neutron beam, and as a function of the energy thereof, such that the sum of the transit times of the neutrons and photons in the scintillator are substantially independent of the points of scintillations within the scintillator. Extrapolated zero timing is employed rather than the usual constant fraction timing. As a result, a substantially larger scintillator can be employed that substantially increases the data rate and shortens the experiment time.

  8. Development and characterization of a 2D scintillation detector for quality assurance in scanned carbon ion beams

    Science.gov (United States)

    Tamborini, A.; Raffaele, L.; Mirandola, A.; Molinelli, S.; Viviani, C.; Spampinato, S.; Ciocca, M.

    2016-04-01

    At the Centro Nazionale di Adroterapia Oncologica (CNAO Foundation), a two-dimensional high resolution scintillating dosimetry system has been developed and tested for daily Quality Assurance measurements (QA) in carbon ion radiotherapy with active scanning technique, for both single pencil beams and scanned fields produced by a synchrotron accelerator. The detector consists of a thin plane organic scintillator (25×25 cm2, 2 mm thick) coupled with a high spatial resolution CCD camera (0.25 mm) in a light-tight box. A dedicated Labview software was developed for image acquisition triggered with the beam extraction, data post-processing and analysis. The scintillator system was preliminary characterized in terms of short-term reproducibility (found to be within±0.5%), linearity with the number of particles (linear fit χ2 = 0.996) and dependence on particle flux (measured to be < 1.5 %). The detector was then tested for single beam spot measurements (Full Width at Half Maximum and position) and for 6×6 cm2 reference scanned field (determination of homogeneity) for carbon ions with energy from 115 MeV/u up to 400 MeV/u. No major differences in the investigated beam parameters measured with scintillator system and the radiochromic EBT3 reference films were observed. The system allows therefore real-time monitoring of the carbon ion beam relevant parameters, with a significant daily time saving with respect to films currently used. The results of this study show the suitability of the scintillation detector for daily QA in a carbon ion facility with an active beam delivery system.

  9. Characteristics of a thermal neutrons scintillation detector with the [ZnS(Ag)+$^6$LiF] at different conditions of measurements

    OpenAIRE

    Alekseenko, V. V.; Barabanov, I. R.; Etezov, R. A.; Gavrilyuk, Yu. M.; Gangapshev, A. M.; Gezhaev, A. M.; Kazalov, V. V.; Khokonov, A. Kh.; V.V. Kuzminov; Panasenko, S. I.; Ratkevich, S. S.

    2015-01-01

    A construction of a thermal neutron testing detector with a thin [ZnS(Ag)+$^6$LiF] scintillator is described. Results of an investigation of sources of the detector pulse origin and the pulse features in a ground and underground conditions are presented. Measurements of the scintillator own background, registration efficiency and a neutron flux at different objects of the BNO INR RAS were performed. The results are compared with the ones measured by the $^3$He proportional counter.

  10. Early clinical experience utilizing scintillator with optical fiber (SOF) detector in clinical boron neutron capture therapy: its issues and solutions

    OpenAIRE

    Ishikawa, Masayori; Yamamoto, Tetsuya; Matsumura, Akira; Hiratsuka, Junichi; Miyatake, Shin-Ichi; Kato, Itsuro; Sakurai, Yoshinori; Kumada, Hiroaki; Shrestha, Shubhechha J.; ONO, KOJI

    2016-01-01

    Background Real-time measurement of thermal neutrons in the tumor region is essential for proper evaluation of the absorbed dose in boron neutron capture therapy (BNCT) treatment. The gold wire activation method has been routinely used to measure the neutron flux distribution in BNCT irradiation, but a real-time measurement using gold wire is not possible. To overcome this issue, the scintillator with optical fiber (SOF) detector has been developed. The purpose of this study is to demonstrate...

  11. Development of a liquid scintillator-based 3D detector for range measurements of spot-scanned proton beams

    Science.gov (United States)

    Darne, C. D.; Robertson, D.; Beddar, S.

    2017-05-01

    The goal of the present study is to develop a liquid scintillator-based 3D detector and investigate its performance for beam range measurements in real time. The detector design consists of a tank filled with water-equivalent liquid scintillator that scintillates in response to incident proton beams. Three scientific complementary metal-oxide semiconductor (sCMOS) cameras collect the resulting optical signals. Preliminary measurements have shown that the optical detection system can record light distribution profiles anywhere inside the tank with an average spatial resolution of 0.23 mm. By employing multiple cameras the system is capable of capturing high resolution 2D depth and beams-eye profiles of the delivered beam and can consequently localize the position of beam anywhere inside the tank. It is also shown that it is capable of accurately measuring proton beam range with no more than 0.3 mm difference from the nominal range. The detector system thus demonstrates its ability to perform fast, high-resolution, and precise beam range measurements in 3D.

  12. Characterization of a LaBr3 scintillator with multi-cell Silicon Drift Detector (SDD) readout

    Science.gov (United States)

    Fuschino, F.; Labanti, C.; Campana, R.; Gangemi, G. C.; Marisaldi, M.; Rignanese, L. P.; Baldazzi, G.; Elmi, I.; Evangelista, Y.; Feroci, M.; Zampa, G.; Zampa, N.; Rashevsky, A.; Vacchi, A.; Rashevskaya, I.; Fabiani, S.; Zorzi, N.; Piemonte, C.; Bellutti, P.; Ficorella, F.; Borghi, G.; Burderi, L.

    2016-07-01

    A scintillation gamma-ray detector, composed of a commercial 0.5" thick, 0.5" diameter LaBr3(Ce) crystal coupled to a 7-cell hexagonal Silicon Drift Detector has been developed and tested. The characterization with X-rays and gamma rays is presented and discussed also within the context of the optical properties of the readout system. A final comparison between our results and state of the art is also discussed in order to propose this prototype for astrophysical applications.

  13. Plastic scintillator with effective pulse shape discrimination for neutron and gamma detection

    Science.gov (United States)

    Zaitseva, Natalia P.; Carman, M Leslie; Cherepy, Nerine; Glenn, Andrew M.; Hamel, Sebastien; Payne, Stephen A.; Rupert, Benjamin L.

    2016-04-12

    In one embodiment, a scintillator material includes a polymer matrix; and a primary dye in the polymer matrix, the primary dye being a fluorescent dye, the primary dye being present in an amount of 5 wt % or more; wherein the scintillator material exhibits an optical response signature for neutrons that is different than an optical response signature for gamma rays. In another embodiment, a scintillator material includes a polymer matrix; and a primary dye in the polymer matrix, the primary dye being a fluorescent dye, the primary dye being present in an amount greater than 10 wt %.

  14. Plastic scintillator with effective pulse shape discrimination for neutron and gamma detection

    Energy Technology Data Exchange (ETDEWEB)

    Zaitseva, Natalia P.; Carman, M Leslie; Cherepy, Nerine; Glenn, Andrew M.; Hamel, Sebastien; Payne, Stephen A.; Rupert, Benjamin L.

    2016-04-12

    In one embodiment, a scintillator material includes a polymer matrix; and a primary dye in the polymer matrix, the primary dye being a fluorescent dye, the primary dye being present in an amount of 5 wt % or more; wherein the scintillator material exhibits an optical response signature for neutrons that is different than an optical response signature for gamma rays. In another embodiment, a scintillator material includes a polymer matrix; and a primary dye in the polymer matrix, the primary dye being a fluorescent dye, the primary dye being present in an amount greater than 10 wt %.

  15. Neutron and photon spectrometry with liquid scintillation detectors in mixed fields

    CERN Document Server

    Klein, H

    2002-01-01

    Liquid scintillation detectors of type NE213 or BC501A are well suited and routinely used for spectrometry in mixed n-gamma-fields. Neutron- and photon-induced pulse height spectra may be simultaneously recorded making use of the n/gamma-discrimination capability based on pulse shape analysis. The light output functions for the detected secondary charged particles, i.e. electrons, positrons, protons and other charged reaction products, and the pulse height resolution function must carefully be determined. This can be done experimentally, in part via an iterative procedure by comparison with calculations. The response functions can then be reliably calculated by Monte Carlo simulations. Photon response functions calculated with the PHRESP code, which was developed on the basis of the EGS4+PRESTA program package, are in very good agreement with calibrations up to 17 MeV, both in shape and absolute scale. Similarly, neutron response functions calculated with the NRESP7 code well describe the pulse height spectra...

  16. Radiopurity of a CeBr{sub 3} crystal used as scintillation detector

    Energy Technology Data Exchange (ETDEWEB)

    Lutter, Guillaume, E-mail: guillaume.lutter@ec.europa.eu [European Commission, DG JRC, Institute for Reference Materials and Measurements (IRMM), Retieseweg 111, 2440 Geel (Belgium); Hult, Mikael [European Commission, DG JRC, Institute for Reference Materials and Measurements (IRMM), Retieseweg 111, 2440 Geel (Belgium); Billnert, Robert [European Commission, DG JRC, Institute for Reference Materials and Measurements (IRMM), Retieseweg 111, 2440 Geel (Belgium); Fundamental Fysik, Chalmers Tekniska Högskola, 41296 Göteborg (Sweden); Oberstedt, Andreas [Fundamental Fysik, Chalmers Tekniska Högskola, 41296 Göteborg (Sweden); Oberstedt, Stephan; Andreotti, Erica; Marissens, Gerd; Rosengård, Ulf; Tzika, Faidra [European Commission, DG JRC, Institute for Reference Materials and Measurements (IRMM), Retieseweg 111, 2440 Geel (Belgium)

    2013-03-01

    Cerium bromide (CeBr{sub 3}) has recently been shown to exhibit several properties making it a suitable material as a scintillation detector in nuclear physics applications. The intrinsic activity of gamma-ray emitting radionuclides in a 38.1 mm×38.1 mm (diameter×height) crystal of CeBr{sub 3} was investigated. The measurements were carried out in the HADES underground laboratory located 225 m underground. Two primordial radionuclides were detected; {sup 227}Ac (and its daughters) with massic activity of 0.30±0.02 Bq/kg and {sup 138}La with massic activity of 7.4±1.0 mBq/kg. Two activation products were also detected; {sup 139}Ce and {sup 82}Br. Their massic activities (assuming a homogeneous distribution in the crystal) just before taking the CeBr{sub 3} crystal underground were 4.3±0.3 mBq/kg and 18±4 mBq/kg correspondingly. None of the other common primordial radionuclides ({sup 40}K, {sup 226}Ra, {sup 228}Ra, {sup 228}Th, and {sup 235}U) were detected and their detection limits were below 2 mBq/kg except for {sup 238}U for which the upper limit was 135 mBq/kg and {sup 210}Pb with an upper limit of 600 mBq/kg.

  17. SuperTIGER scintillator detector calibration with 30 GeV/nucleon Pb and its fragments

    Science.gov (United States)

    Sasaki, Makoto

    2016-07-01

    The SuperTIGER (Super Trans-Iron Galactic Element Recorder) long-duration balloon instrument has measured the abundances of galactic cosmic-ray elements to provide sensitive tests and clarification of the OB-association model of Galactic cosmic-ray origins. More than 600 nuclei with atomic number Z > 30 were observed on its first flight and the abundances of nuclei have been determined with clear individual element resolution and high statistical precision for 30 energy 30 GeV/nucleon Pb and its fragments to measure the saturation response of the scintillator detectors, which are essential to determine the abundances of nuclei with atomic number Z > 40. The beamtest results have been used to optimize the Geant4 simulation to represent the flight data, and will be used to interpret the flight data to extend the abundance determination to about _{60}Nd. SuperTIGER was developed by Washington University in St. Louis, NASA Goddard Flight Center, the California Institute of Technology, Jet Propulsion Laboratory, and the University of Minnesota.

  18. Fast neutron tomography with real-time pulse-shape discrimination in organic scintillation detectors

    Science.gov (United States)

    Joyce, Malcolm J.; Agar, Stewart; Aspinall, Michael D.; Beaumont, Jonathan S.; Colley, Edmund; Colling, Miriam; Dykes, Joseph; Kardasopoulos, Phoevos; Mitton, Katie

    2016-10-01

    A fast neutron tomography system based on the use of real-time pulse-shape discrimination in 7 organic liquid scintillation detectors is described. The system has been tested with a californium-252 source of dose rate 163 μSv/h at 1 m and neutron emission rate of 1.5×107 per second into 4π and a maximum acquisition time of 2 h, to characterize two 100×100×100 mm3 concrete samples. The first of these was a solid sample and the second has a vertical, cylindrical void. The experimental data, supported by simulations with both Monte Carlo methods and MATLAB®, indicate that the presence of the internal cylindrical void, corners and inhomogeneities in the samples can be discerned. The potential for fast neutron assay of this type with the capability to probe hydrogenous features in large low-Z samples is discussed. Neutron tomography of bulk porous samples is achieved that combines effective penetration not possible with thermal neutrons in the absence of beam hardening.

  19. Simulation and Design of Multi-modulars Detector System of Gadolinium-Loaded Liquid Scintillator

    Institute of Scientific and Technical Information of China (English)

    HOU; Long; WANG; Zhao-hui; YU; Guo-liang; WANG; Qi; KANG; Guo-guo; SU; Xiao-bin; ZHANG; Xiao-peng; ZHANG; Kai

    2012-01-01

    <正>The gadolinium-loaded liquid scintillator has the superiority of high detecting efficiency, and it can be used to measure many kinds of nucleus. We improved this technique and construct a 4π liquid scintillator detecting systems which is composed by many liquid scintillators. By coupling with fission chamber, we form a novel research platform which can be used to measure the (n, 2n) and (n, 3n) cross sections of many nuclei.

  20. Muon detection with scintillation detectors using indirect SiPM readout

    CERN Document Server

    Struth, Janina

    2010-01-01

    In the scope of this thesis prototypes of silicon photomultipliers with wavelength shifting fibres were measured for muon detection. This indirect readout happens with silizium photomultipliers (SiPM), which are coupled with the fibre. The scintillator was wrapped with different reflective materials to optimise the light amplification. Furthermore two different thicknesses of the scintillator were used to have a comparison between the different light yield. Consequently different scintillator thicknesses were combinded and measured with different wrapping materials to compare their efficiency.

  1. Gamma-gamma coincidence performance of LaBr3:Ce scintillation detectors vs HPGe detectors in high count-rate scenarios.

    Science.gov (United States)

    Drescher, A; Yoho, M; Landsberger, S; Durbin, M; Biegalski, S; Meier, D; Schwantes, J

    2017-04-01

    A radiation detection system consisting of two cerium doped lanthanum bromide (LaBr3:Ce) scintillation detectors in a gamma-gamma coincidence configuration has been used to demonstrate the advantages that coincident detection provides relative to a single detector, and the advantages that LaBr3:Ce detectors provide relative to high purity germanium (HPGe) detectors. Signal to noise ratios of select photopeak pairs for these detectors have been compared to high-purity germanium (HPGe) detectors in both single and coincident detector configurations in order to quantify the performance of each detector configuration. The efficiency and energy resolution of LaBr3:Ce detectors have been determined and compared to HPGe detectors. Coincident gamma-ray pairs from the radionuclides (152)Eu and (133)Ba have been identified in a sample that is dominated by (137)Cs. Gamma-gamma coincidence successfully reduced the Compton continuum from the large (137)Cs peak, revealed several coincident gamma energies characteristic of these nuclides, and improved the signal-to-noise ratio relative to single detector measurements. LaBr3:Ce detectors performed at count rates multiple times higher than can be achieved with HPGe detectors. The standard background spectrum consisting of peaks associated with transitions within the LaBr3:Ce crystal has also been significantly reduced. It is shown that LaBr3:Ce detectors have the unique capability to perform gamma-gamma coincidence measurements in very high count rate scenarios, which can potentially benefit nuclear safeguards in situ measurements of spent nuclear fuel. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. PALS investigations of free volumes thermal expansion of J-PET plastic scintillator synthesized in polystyrene matrix

    Directory of Open Access Journals (Sweden)

    Wieczorek Anna

    2015-12-01

    Full Text Available The polystyrene doped with 2,5-diphenyloxazole as a primary fluor and 2-(4-styrylphenylbenzoxazole as a wavelength shifter prepared as a plastic scintillator was investigated using positronium probe in wide range of temperatures from 123 to 423 K. Three structural transitions at 260, 283, and 370 K were found in the material. In the o-Ps intensity dependence on temperature, the significant hysteresis is observed. Heated to 370 K, the material exhibits the o-Ps intensity variations in time.

  3. Radiostrontium separation and measurement in a single step using plastic scintillators plus selective extractants. Application to aqueous sample analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bagan, H.; Tarancon, A.; Rauret, G. [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 647, E-08028 Barcelona (Spain); Garcia, J.F., E-mail: jfgarcia@ub.edu [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 647, E-08028 Barcelona (Spain)

    2011-02-07

    This study describes a new protocol for {sup 90}Sr determination in water samples based on the use of a selective extractant (DtBuCH18C6) and plastic scintillator microspheres. The proposed procedure unifies chemical separation and sample measurement preparation in a single step to reduce the effort, time and reagents required for analysis. In addition, the final measurement does not produce mixed waste. The minimum activity detectable for 10 mL of sample solution is 0.46 Bq L{sup -1}. Relative errors for the determination of {sup 90}Sr activity in drinking, sea and river waters are less than 4%.

  4. PALS investigations of free volumes thermal expansion of J-PET plastic scintillator synthesized in polystyrene matrix

    CERN Document Server

    Wieczorek, A; Jasińska, B; Gorgol, M; Bednarski, T; Białas, P; Czerwiński, E; Gajos, A; Kamińska, D; Kapłon, Ł; Kochanowski, A; Korcyl, G; Kowalski, P; Kozik, T; Krzemień, W; Kubicz, E; Niedźwiecki, S; Pałka, M; Raczyński, L; Rudy, Z; Rundel, O; Sharma, N G; Silarski, M; Słomski, A; Strzelecki, A; Wiślicki, W; Zieliński, M; Moskal, P

    2015-01-01

    The polystyrene dopped with 2,5-diphenyloxazole as a primary fluor and 2-(4-styrylphenyl)benzoxazole as a wavelength shifter, prepared as a plastic scintillator was investigated using positronium probe in wide range of temperatures from 123 to 423 K. Three structural transitions at 260 K, 283 K and 370 K were found in the material. In the o-Ps intensity dependence on temperature, the significant hysteresis is observed. Heated to 370 K, the material exhibits the o-Ps intensity variations in time.

  5. Low background detector with enriched 116CdWO4 crystal scintillators to search for double beta decay of 116Cd

    CERN Document Server

    Barabash, A S; Bernabei, R; Boiko, R S; Cappella, F; Caracciolo, V; Chernyak, D M; Cerulli, R; Danevich, F A; Di Vacri, M L; Dossovitskiy, A E; Galashov, E N; Incicchitti, A; Kobychev, V V; Konovalov, S I; Kovtun, G P; Kudovbenko, V M; Laubenstein, M; Mikhlin, A L; Nisi, S; Poda, D V; Podviyanuk, R B; Polischuk, O G; Shcherban, A P; Shlegel, V N; Solopikhin, D A; Stenin, Yu G; Tretyak, V I; Umatov, V I; Vasiliev, Ya V; Virich, V D

    2011-01-01

    A cadmium tungstate crystal boule enriched in $^{116}$Cd to 82% with mass of 1868 g was grown by the low-thermal-gradient Czochralski technique. The isotopic composition of cadmium and the trace contamination of the crystal were estimated by High Resolution Inductively Coupled Plasma Mass-Spectrometry. The crystal scintillators produced from the boule were subjected to characterization that included measurements of transmittance and energy resolution. A low background scintillation detector with two $^{116}$CdWO$_4$ crystal scintillators (586 g and 589 g) was developed. The detector was running over 1727 h deep underground at the Gran Sasso National Laboratories of the INFN (Italy), which allowed to estimate the radioactive contamination of the enriched crystal scintillators. The radiopurity of a third $^{116}$CdWO$_4$ sample (326 g) was tested with the help of ultra-low background high purity germanium $\\gamma$ detector. Monte Carlo simulations of double $\\beta$ processes in $^{116}$Cd were used to estimate ...

  6. A novel fast-neutron tomography system based on a plastic scintillator array and a compact D-D neutron generator.

    Science.gov (United States)

    Adams, Robert; Zboray, Robert; Prasser, Horst-Michael

    2016-01-01

    Very few experimental imaging studies using a compact neutron generator have been published, and to the knowledge of the authors none have included tomography results using multiple projection angles. Radiography results with a neutron generator, scintillator screen, and camera can be seen in Bogolubov et al. (2005), Cremer et al. (2012), and Li et al. (2014). Comparable results with a position-sensitive photomultiplier tube can be seen in Popov et al. (2011). One study using an array of individual fast neutron detectors in the context of cargo scanning for security purposes is detailed in Eberhardt et al. (2005). In that case, however, the emphasis was on very large objects with a resolution on the order of 1cm, whereas this study focuses on less massive objects and a finer spatial resolution. In Andersson et al. (2014) three fast neutron counters and a D-T generator were used to perform attenuation measurements of test phantoms. Based on the axisymmetry of the test phantoms, the single-projection information was used to calculate radial attenuation distributions of the object, which was compared with the known geometry. In this paper a fast-neutron tomography system based on an array of individual detectors and a purpose-designed compact D-D neutron generator is presented. Each of the 88 detectors consists of a plastic scintillator read out by two Silicon photomultipliers and a dedicated pulse-processing board. Data acquisition for all channels was handled by four single-board microcontrollers. Details of the individual detector design and testing are elaborated upon. Using the complete array, several fast-neutron images of test phantoms were reconstructed, one of which was compared with results using a Co-60 gamma source. The system was shown to be capable of 2mm resolution, with exposure times on the order of several hours per reconstructed tomogram. Details about these measurements and the analysis of the reconstructed images are given, along with a discussion

  7. Thin-film scintillators for extended ultraviolet /UV/ response silicon detectors

    Science.gov (United States)

    Viehmann, W.

    1979-01-01

    The preparation and radiometric properties of silicon detectors coated with fluorescent thin films are described. The films are deposited from solutions of clear plastics, such as acrylic resins, polyvinyl toluene or polystyrene, and of organic laser dyes in a common solvent. They are optically clear, mechanically and chemically stable, yet easily applied and removed. Multiple doped films of a few microns thickness exhibit broad-band absorption from less than 250 nm to about 450 nm and narrow band emissions with peaks ranging from 380 nm to 600 nm. Internal quantum efficiencies are close to 100 percent and fluorescence decay times are in the nanosecond range. When deposited on optically denser media, a large fraction of the fluorescent emission is trapped in the substrate. Silicon photodiodes coated with multiple doped films exhibit high external quantum efficiencies and virtually flat photon response in the near UV.

  8. Thin-film scintillators for extended ultraviolet /UV/ response silicon detectors

    Science.gov (United States)

    Viehmann, W.

    1979-01-01

    The preparation and radiometric properties of silicon detectors coated with fluorescent thin films are described. The films are deposited from solutions of clear plastics, such as acrylic resins, polyvinyl toluene or polystyrene, and of organic laser dyes in a common solvent. They are optically clear, mechanically and chemically stable, yet easily applied and removed. Multiple doped films of a few microns thickness exhibit broad-band absorption from less than 250 nm to about 450 nm and narrow band emissions with peaks ranging from 380 nm to 600 nm. Internal quantum efficiencies are close to 100 percent and fluorescence decay times are in the nanosecond range. When deposited on optically denser media, a large fraction of the fluorescent emission is trapped in the substrate. Silicon photodiodes coated with multiple doped films exhibit high external quantum efficiencies and virtually flat photon response in the near UV.

  9. Effect of x-ray incident direction and scintillator layer design on image quality of indirect-conversion flat-panel detector with GOS phosphor

    Science.gov (United States)

    Sato, K.; Nariyuki, F.; Nomura, H.; Takasu, A.; Fukui, S.; Nakatsu, M.; Okada, Y.; Nabeta, T.; Hosoi, Y.

    2011-03-01

    In this study, we characterized the image quality of two types of indirect-conversion flat-panel detectors: an X-ray incident-side photo-detection system (IS) and an X-ray penetration-side photo-detection system (PS). These detectors consist of a Gd2O2S:Tb (GOS) scintillator coupled with a photodiode thin film transistor (PD-TFT) array on a glass substrate. The detectors have different X-ray incident directions, glass substrates, and scintillators. We also characterized the effects of layered scintillator structures on the image quality by using a single-layered scintillator containing large phosphor grains and a double-layered scintillator consisting of a layer of large phosphor grains and a layer of small phosphor grains. The IS system consistently demonstrated a higher MTF than the PS system for a scintillator of the same thickness. Moreover, the IS system showed a higher DQE than the PS system when a thick scintillator was used. While the double-layered scintillators were useful for improving the MTF in both systems, a thick single-layered scintillator was preferable for obtaining a high DQE when the IS system was applied. These results indicate that an IS system can efficiently utilize the light emitted from the phosphor at the far side of the PD without the occurrence of blurring. The use of IS systems makes it possible to increase the thickness of the scintillator layer for improving the sensitivity without reducing the MTF, which increases the DQE. The DQE of the IS system was 1.2 times that of the PS system, despite the absorption of X-rays at the glass substrate before entering the phosphor.

  10. 用于强γ环境中测量中子参数的薄膜塑料闪烁探测器%Thin Plastic Scintillating Foil for Measuring Pulsed Neutron Flux in High Gamma-Ray Environment

    Institute of Scientific and Technical Information of China (English)

    欧阳晓平; 李真富; 王群书; 霍裕昆

    2005-01-01

    提出了在强γ环境中脉冲中子通量的薄膜闪烁体测量方法. 根据其与中子、γ响应的理论计算结果,研制成功一种对γ不灵敏,用于探测快脉冲中子通量的新型探测器. 该探测器由塑料薄膜闪烁体+光电探测器构成. 与传统探测器相比,该探测器具有如下特点:1.高中子灵敏度;2.高n/γ分辨;3.在给定能区具有平坦的能量响应.%A new conception of measuring pulsed neutron flux in high gamma-ray environment with a thin plastic scintillating foil is presented. Based on the calculations of the response to neutrons and gamma-rays, a new gamma-insensitive detector for detecting fast rising, transient neutron flux has been developed and preliminarily tested, which comprises a thin plastic scintillating foil of ST401 (TPSF) and a photomultiplier tube (or a photodiode). The detector exhibits three distinct properties compared with the conventional ones: (1) high neutron sensitivity, (2) high n/γ discrimination, and (3) flat response in the given neutron energy range.

  11. Study of scintillation, fluorescence and scattering in mineral oil for the MiniBooNE neutrino detector

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Bruce C.; Brice, Stephen; Hawker, Eric; Maza, Shannon; Meyer, Hans-Otto; Pla-Dalmau, Anna; Tayloe, Rex; Tanaka, Hirohisa A.; Toptygin, Dmitri; /Fermilab /Western

    2004-11-01

    The MiniBooNE neutrino detector at Fermilab (FNAL) is filled with 250,000 gallons of pure mineral oil. The principal signal for MiniBooNE is light observed in a prompt Cherenkov cone. Scattering and fluorescence modify our detection of this light. Scintillation is also created by ionization in the oil. Studies of fluorescence of this oil have been carried out over a wide spectrum of exciting light and time resolved fluorescence with a narrower range of excitation. Polarized scattering measurements have been carried out at longer wavelengths. Time resolved and spectrally resolved scintillation has been studied with a 200 MeV Proton beam at the Indiana University Cyclotron Facility. Results of these studies will be reported.

  12. System and plastic scintillator for discrimination of thermal neutron, fast neutron, and gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Zaitseva, Natalia P.; Carman, M. Leslie; Faust, Michelle A.; Glenn, Andrew M.; Martinez, H. Paul; Pawelczak, Iwona A.; Payne, Stephen A.

    2017-05-16

    A scintillator material according to one embodiment includes a polymer matrix; a primary dye in the polymer matrix, the primary dye being a fluorescent dye, the primary dye being present in an amount of 3 wt % or more; and at least one component in the polymer matrix, the component being selected from a group consisting of B, Li, Gd, a B-containing compound, a Li-containing compound and a Gd-containing compound, wherein the scintillator material exhibits an optical response signature for thermal neutrons that is different than an optical response signature for fast neutrons and gamma rays. A system according to one embodiment includes a scintillator material as disclosed herein and a photodetector for detecting the response of the material to fast neutron, thermal neutron and gamma ray irradiation.

  13. A high-spatial-resolution three-dimensional detector array for 30-200 keV X-rays based on structured scintillators

    DEFF Research Database (Denmark)

    Olsen, Ulrik Lund; Schmidt, Søren; Poulsen, Henning Friis

    2008-01-01

    A three-dimensional X-ray detector for imaging 30-200 keV photons is described. It comprises a set of semi-transparent structured scintillators, where each scintillator is a regular array of waveguides in silicon, and with pores filled with CsI. The performance of the detector is described theore...... in efficiency by a factor of 5-15 is obtainable. The cross-talk between screens in the three-dimensional detector is shown to be negligible. The three-dimensional concept enables ray-tracing and super-resolution algorithms to be applied....

  14. Development of an optical fiber type detector using a Eu:LiCaAlF{sub 6} scintillator for neutron monitoring in boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Kenichi, E-mail: k-watanabe@nucl.nagoya-u.ac.jp [Nagoya University, Furo-cho, Chikusa-ku, Nagoya, 464-8603 (Japan); Kawabata, Yuya; Yamazaki, Atsushi; Uritani, Akira; Iguchi, Tetsuo [Nagoya University, Furo-cho, Chikusa-ku, Nagoya, 464-8603 (Japan); Fukuda, Kentaro [Tokuyama Corp., 1-1 Mikage-cho, Shunan-shi, Yamaguchi, 745-8648 (Japan); Yanagida, Takayuki [Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma, Nara, 630-0192 (Japan)

    2015-12-01

    We have developed a small neutron detector probe as a thermal neutron flux monitor for boron neutron capture therapy. The detector consists of an optical fiber and a small Eu:LiCaAlF{sub 6} scintillator. In order to improve neutron-gamma ray discrimination capability, we use the small-size scintillator, whose size is controlled to be smaller than fast electron range produced by gamma-rays and larger than the range of charged particles induced by {sup 6}Li(n,t) reactions. We confirmed the improved neutron-gamma ray discrimination capability by comparing the detector responses between a small-size scintillator and a slab one. We also evaluated the neutron sensitivity of the fabricated optical fiber type neutron detector to be 2×10{sup −4} cm{sup 2}.

  15. Temperature variations as a source of uncertainty in medical fiber-coupled organic plastic scintillator dosimetry

    DEFF Research Database (Denmark)

    Buranurak, Siritorn; Andersen, Claus Erik; Beierholm, Anders Ravnsborg

    2013-01-01

    commonly used scintillating fibers would change with temperature in the clinical range (15–40 °C). The study showed that the light yield in the peak regions of the scintillators studied decreases linearly with increasing temperature. For the blue BCF-12 and the green BCF-60 from Saint-Gobain, France we...... found temperature coefficients of −0.15 ± 0.01%/K and −0.55 ± 0.04%/K, respectively. These values are sufficiently large to warrant careful consideration for clinical measurements. © 2013 Elsevier Ltd. All rights reserved....

  16. Recent progress of MPPC-based scintillation detectors in high precision X-ray and gamma-ray imaging

    Science.gov (United States)

    Kataoka, J.; Kishimoto, A.; Fujita, T.; Nishiyama, T.; Kurei, Y.; Tsujikawa, T.; Oshima, T.; Taya, T.; Iwamoto, Y.; Ogata, H.; Okochi, H.; Ohsuka, S.; Ikeda, H.; Yamamoto, S.

    2015-06-01

    The multi-pixel photon counter (MPPC) is a promising light sensor for various applications, not only in physics experiments but also in nuclear medicine, industry, and even high-energy astrophysics. In this paper, we present the current status and most recent progress of the MPPC-based scintillation detectors, such as (1) a high-precision X-ray and gamma-ray spectral image sensor, (2) next-generation PET detectors with MRI, TOF, and DOI measurement capabilities, and (3) a compact gamma camera for environmental radiation surveys. We first present a new method of fabricating a Ce:GAGG scintillator plate (1 or 2 mm thick) with ultra-fine resolution (0.2 mm/pixel), cut using a dicing saw to create 50 μm wide micro-grooves. When the plate is optically coupled with a large-area MPPC array, excellent spatial resolution of 0.48 mm (FWHM) and energy resolution of 14% (FWHM) are obtained for 122 keV gamma rays. Hence, the detector can act as a convenient "multi-color" imaging device that can potentially be used for future SPECT and photon-counting CT. We then show a prototype system for a high-resolution MPPC-based PET scanner that can realize ≃1 mm (FWHM) spatial resolution, even under a strong magnetic field of 4.7 T. We develop a front-end ASIC intended for future TOF-PET scanner with a 16-channel readout that achieves a coincidence time resolution of 489 ps (FWHM). A novel design for a module with DOI-measurement capability for gamma rays is also presented by measuring the pulse height ratio of double-sided MPPCs coupled at both ends of scintillation crystal block. Finally, we present the concept of a two-plane Compton camera consisting of Ce:GAGG scintillator arrays coupled with thin MPPC arrays. As a result of the thin and compact features of the MPPC device, the camera not only achieves a small size (14×14×15 cm3) and light weight (1.9 kg) but also excellent sensitivity, compared to the conventional PMT-based pinhole camera used in Fukushima. Finally, we briefly

  17. SU-D-BRC-07: System Design for a 3D Volumetric Scintillation Detector Using SCMOS Cameras

    Energy Technology Data Exchange (ETDEWEB)

    Darne, C; Robertson, D; Alsanea, F; Beddar, S [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: The purpose of this project is to build a volumetric scintillation detector for quantitative imaging of 3D dose distributions of proton beams accurately in near real-time. Methods: The liquid scintillator (LS) detector consists of a transparent acrylic tank (20×20×20 cm{sup 3}) filled with a liquid scintillator that when irradiated with protons generates scintillation light. To track rapid spatial and dose variations in spot scanning proton beams we used three scientific-complementary metal-oxide semiconductor (sCMOS) imagers (2560×2160 pixels). The cameras collect optical signal from three orthogonal projections. To reduce system footprint two mirrors oriented at 45° to the tank surfaces redirect scintillation light to cameras for capturing top and right views. Selection of fixed focal length objective lenses for these cameras was based on their ability to provide large depth of field (DoF) and required field of view (FoV). Multiple cross-hairs imprinted on the tank surfaces allow for image corrections arising from camera perspective and refraction. Results: We determined that by setting sCMOS to 16-bit dynamic range, truncating its FoV (1100×1100 pixels) to image the entire volume of the LS detector, and using 5.6 msec integration time imaging rate can be ramped up to 88 frames per second (fps). 20 mm focal length lens provides a 20 cm imaging DoF and 0.24 mm/pixel resolution. Master-slave camera configuration enable the slaves to initiate image acquisition instantly (within 2 µsec) after receiving a trigger signal. A computer with 128 GB RAM was used for spooling images from the cameras and can sustain a maximum recording time of 2 min per camera at 75 fps. Conclusion: The three sCMOS cameras are capable of high speed imaging. They can therefore be used for quick, high-resolution, and precise mapping of dose distributions from scanned spot proton beams in three dimensions.

  18. The light-yield response of a NE-213 liquid-scintillator detector measured using 2 -- 6 MeV tagged neutrons

    CERN Document Server

    Scherzinger, J; Annand, J R M; Fissum, K G; Hall-Wilton, R; Kanaki, K; Lundin, M; Nilsson, B; Perrey, H; Rosborg, A; Svensson, H

    2016-01-01

    The response of a NE-213 liquid-scintillator detector has been measured using tagged neutrons from 2--6 MeV originating from an Am/Be neutron source. The neutron energies were determined using the time-of-flight technique. Pulse-shape discrimination was employed to discern between gamma-rays and neutrons. The behavior of both the fast (35 ns) and the combined fast and slow (475 ns) components of the neutron scintillation-light pulses were studied. Three different prescriptions were used to relate the neutron maximum energy-transfer edges to the corresponding recoil-proton scintillation-light yields, and the results were compared to simulations. Parametrizations which predict the fast or total light yield of the scintillation pulses were also tested. Our results agree with both existing data and existing parametrizations. We observe a clear sensitivity to the portion and length of the neutron scintillation-light pulse considered.

  19. ANTS — a simulation package for secondary scintillation Anger-camera type detector in thermal neutron imaging

    Science.gov (United States)

    Morozov, A.; Defendi, I.; Engels, R.; Fraga, F. A. F.; Fraga, M. M. F. R.; Guerard, B.; Jurkovic, M.; Kemmerling, G.; Manzin, G.; Margato, L. M. S.; Niko, H.; Pereira, L.; Petrillo, C.; Peyaud, A.; Piscitelli, F.; Raspino, D.; Rhodes, N. J.; Sacchetti, F.; Schooneveld, E. M.; Van Esch, P.; Zeitelhack, K.

    2012-08-01

    A custom and fully interactive simulation package ANTS (Anger-camera type Neutron detector: Toolkit for Simulations) has been developed to optimize the design and operation conditions of secondary scintillation Anger-camera type gaseous detectors for thermal neutron imaging. The simulation code accounts for all physical processes related to the neutron capture, energy deposition pattern, drift of electrons of the primary ionization and secondary scintillation. The photons are traced considering the wavelength-resolved refraction and transmission of the output window. Photo-detection accounts for the wavelength-resolved quantum efficiency, angular response, area sensitivity, gain and single-photoelectron spectra of the photomultipliers (PMTs). The package allows for several geometrical shapes of the PMT photocathode (round, hexagonal and square) and offers a flexible PMT array configuration: up to 100 PMTs in a custom arrangement with the square or hexagonal packing. Several read-out patterns of the PMT array are implemented. Reconstruction of the neutron capture position (projection on the plane of the light emission) is performed using the center of gravity, maximum likelihood or weighted least squares algorithm. Simulation results reproduce well the preliminary results obtained with a small-scale detector prototype. ANTS executables can be downloaded from http://coimbra.lip.pt/~andrei/.

  20. Study of digital pulse shape discrimination method for n-{\\gamma} separation of EJ-301 liquid scintillation detector

    CERN Document Server

    Wan, Bo; Chen, Liang; Ge, Honglin; Ma, Fei; Zhang, Hongbin; Ju, Yongqin; Zhang, Yanbin; Li, Yanyan; Xu, Xiaowei

    2015-01-01

    A digital pulse shape discrimination system based on a programmable module NI-5772 has been established and tested with EJ-301 liquid scintillation detector. The module was operated by means of running programs developed in LabVIEW with the sampling frequency up to 1.6GS/s. Standard gamma sources 22Na, 137Cs and 60Co were used to calibrate the EJ-301 liquid scintillation detector, and the gamma response function has been obtained. Digital algorithms for charge comparison method and zero-crossing method have been developed. The experimental results showed that both digital signal processing (DSP) algorithms could discriminate neutrons from gamma-rays. Moreover, the zero-crossing method shows better n-{\\gamma} discrimination at 80 keVee and lower, whereas the charge comparison method gives better results at higher thresholds. In addition, the figure-of-merit (FOM) of two different dimension detectors were extracted at 9 energy thresholds, and it was found that the smaller one presented a better n-{\\gamma} separ...

  1. Signal pulse emulation for scintillation detectors using Geant4 Monte Carlo with light tracking simulation

    Energy Technology Data Exchange (ETDEWEB)

    Ogawara, R. [Department of Medical Physics and Engineering, Graduate School of Medicine, Hokkaido University, Kita-15 Nishi-7, Kita-ku, Sapporo-shi, Hokkaido (Japan); Ishikawa, M., E-mail: masayori@med.hokudai.ac.jp [Graduate School of Health Science, Hokkaido University, Kita-12 Nishi-5, Kita-ku, Sapporo-shi, Hokkaido (Japan)

    2016-07-15

    The anode pulse of a photomultiplier tube (PMT) coupled with a scintillator is used for pulse shape discrimination (PSD) analysis. We have developed a novel emulation technique for the PMT anode pulse based on optical photon transport and a PMT response function. The photon transport was calculated using Geant4 Monte Carlo code and the response function with a BC408 organic scintillator. The obtained percentage RMS value of the difference between the measured and simulated pulse with suitable scintillation properties using GSO:Ce (0.4, 1.0, 1.5 mol%), LaBr{sub 3}:Ce and BGO scintillators were 2.41%, 2.58%, 2.16%, 2.01%, and 3.32%, respectively. The proposed technique demonstrates high reproducibility of the measured pulse and can be applied to simulation studies of various radiation measurements.

  2. A scintillator-based online detector for the angularly resolved measurement of laser-accelerated proton spectra

    Energy Technology Data Exchange (ETDEWEB)

    Metzkes, J.; Kraft, S. D.; Sobiella, M.; Stiller, N.; Zeil, K.; Schramm, U. [Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstr. 400, 01328 Dresden (Germany); Karsch, L.; Schuerer, M. [OncoRay - National Center for Radiation Research in Oncology, TU Dresden, Fetscherstr. 74, 01307 Dresden (Germany); Pawelke, J.; Richter, C. [Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstr. 400, 01328 Dresden (Germany); OncoRay - National Center for Radiation Research in Oncology, TU Dresden, Fetscherstr. 74, 01307 Dresden (Germany)

    2012-12-15

    In recent years, a new generation of high repetition rate ({approx}10 Hz), high power ({approx}100 TW) laser systems has stimulated intense research on laser-driven sources for fast protons. Considering experimental instrumentation, this development requires online diagnostics for protons to be added to the established offline detection tools such as solid state track detectors or radiochromic films. In this article, we present the design and characterization of a scintillator-based online detector that gives access to the angularly resolved proton distribution along one spatial dimension and resolves 10 different proton energy ranges. Conceived as an online detector for key parameters in laser-proton acceleration, such as the maximum proton energy and the angular distribution, the detector features a spatial resolution of {approx}1.3 mm and a spectral resolution better than 1.5 MeV for a maximum proton energy above 12 MeV in the current design. Regarding its areas of application, we consider the detector a useful complement to radiochromic films and Thomson parabola spectrometers, capable to give immediate feedback on the experimental performance. The detector was characterized at an electrostatic Van de Graaff tandetron accelerator and tested in a laser-proton acceleration experiment, proving its suitability as a diagnostic device for laser-accelerated protons.

  3. SPORT: A new sub-nanosecond time-resolved instrument to study swift heavy ion-beam induced luminescence - Application to luminescence degradation of a fast plastic scintillator

    CERN Document Server

    Gardés, E; Ban-d'Etat, B; Cassimi, A; Durantel, F; Grygiel, C; Madi, T; Monnet, I; Ramillon, J -M; Ropars, F; Lebius, H

    2013-01-01

    We developed a new sub-nanosecond time-resolved instrument to study the dynamics of UV-visible luminescence under high stopping power heavy ion irradiation. We applied our instrument, called SPORT, on a fast plastic scintillator (BC-400) irradiated with 27-MeV Ar ions having high mean electronic stopping power of 2.6 MeV/\\mu m. As a consequence of increasing permanent radiation damages with increasing ion fluence, our investigations reveal a degradation of scintillation intensity together with, thanks to the time-resolved measurement, a decrease in the decay constant of the scintillator. This combination indicates that luminescence degradation processes by both dynamic and static quenching, the latter mechanism being predominant. Under such high density excitation, the scintillation deterioration of BC-400 is significantly enhanced compared to that observed in previous investigations, mainly performed using light ions. The observed non-linear behaviour implies that the dose at which luminescence starts deteri...

  4. Design of Multi-unit Control System of High Voltage Power Supply for LASCAR Scintillator Detector Array

    Institute of Scientific and Technical Information of China (English)

    WuLijie; WangJinchuan; XiaoGuoqing; GuoZhongyan; ZhanWenlong; QiHuirong; XuZhiguo; ZhangLi; DingXianli; XuHushan; SunZhiyu; LiJiaxing; LiChen; WangMeng; ChenLixin; HuZhengguo; MaoRuishi; ZhaoTiecheng

    2003-01-01

    The power voltages of Photomultipliers (PMTs) at RIBLL LASCAR scintillator detector array are distributed between 900 V and 1 800 V irregularly. 392 CC123 modules are employed to supply high voltage for the PMT array. The CC123 module serves as PMT interface groupware package, and it can transform +12 V DC input voltage to ranges of 0~-2200 V for the PMT power supply corresponding to 0~+5 V output voltage from the control board crate. The relation of PMT power supply with the output voltage of the control crate is shown in Fig.1.

  5. Results of low energy background measurements with the Liquid Scintillation Detector (LSD) of the Mont Blanc Laboratory

    Science.gov (United States)

    Aglietta, M.; Badino, G.; Bologna, G. F.; Castagnoli, C.; Fulgione, W.; Galeotti, P.; Saavedra, O.; Trinchero, G. C.; Vernetto, S.; Dadykin, V. L.

    1985-01-01

    The 90 tons liquid scintillation detector (LSD) is fully running since October 1984, at a depth of 5,200 hg/sq cm of standard rock underground. The main goal is to search for neutrino bursts from collapsing stars. The experiment is very sensitive to detect low energy particles and has a very good signature to gamma-rays from (n,p) reaction which follows the upsilon e + p yields n + e sup + neutrino capture. The analysis of data is presented and the preliminary results on low energy measurements are discussed.

  6. Liquid scintillators and liquefied rare gases for particle detectors. Background-determination in Double Chooz and scintillation properties of liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, Martin Alexander

    2012-11-27

    }(g)/(g)). Both gamma spectroscopy measurements and the BiPo analysis show the high level of radiopurity reached in Double Chooz. In addition, with the BiPo analysis the {alpha}-quenching factors for the Target and the GammaCatcher liquids have been determined, respectively, to 9.94{+-}0.04 and 13.69{+-}0.02 at 7.7 MeV, and 9.05{+-}0.01 and 14.3{+-}0.1 at 8.8 MeV. The former values show a good agreement with the values obtained in a dedicated laboratory measurement. The time stability of the peak position of the {sup 214}Po {alpha}-peak could be proven, too, showing a stable detector performance at low visible energies. The direct search for Dark Matter can, amongst others, be performed with liquid rare gas detectors, which make use of the scintillation light. However, a good background discrimination is needed. Studies on the wavelength- and time-resolved scintillation properties of liquid argon have therefore been carried out with high resolution and best statistics. The results obtained for different ion beams show that particle discrimination is not feasible in any realistic experiment by means of the wavelength-resolved scintillation light only, but the time structure of the emitted light provides a good handle to distinguish between different incident particles. For heavy ions (sulfur) a ratio of the fast to the slow scintillation component of (1.6 {+-} 0.6) is found, while lighter particles (protons) exhibit a ratio of (0.25 {+-} 0.05). The outcome of the present studies shows that this ratio can also be used in wavelength-integrating measurements which have a comparable detection efficiency for wavelengths below and above {proportional_to}170 nm. The present results demonstrate that for a number of 90 detected photons the singlet-to-triplet distributions obtained for sulfur ions and protons as exciting particles cease to overlap. In a Dark Matter experiment, if all photons produced can be detected, this corresponds to a discrimination threshold of only 2.25 keV.

  7. Recent developments of ion beam induced luminescence: radiation hardness study of thin film plastic scintillators

    Science.gov (United States)

    Quaranta, Alberto

    2005-10-01

    Ion beam induced luminescence (IBIL) measurements have been performed on thin film scintillators based on polyvinyltoluene (PVT) and 6FDA-DAD and BPDA-3F polyimides with H+ (1.85 MeV) and He+ (1.8-2.2 MeV) ion beams. The radiation hardness of the undoped polymers has been verified to depend mainly on the deposited energy density, polyimides exhibiting a higher resistance with respect to PVT. In PVT a new fluorescence band, attributed to the radical precursors of the network crosslinking, has been observed. The efficiency of doped polymers degradates with a higher rate, depending on the dye intrinsic lability. At high radiation fluences, the relative efficiency to NE102 of doped polyimides scintillators increases owing to the intrinsic host improved resistance.

  8. Segmented crystalline scintillators: an initial investigation of high quantum efficiency detectors for megavoltage x-ray imaging.

    Science.gov (United States)

    Sawant, Amit; Antonuk, Larry E; El-Mohri, Youcef; Zhao, Qihua; Li, Yixin; Su, Zhong; Wang, Yi; Yamamoto, Jin; Du, Hong; Cunningham, Ian; Klugerman, Misha; Shah, Kanai

    2005-10-01

    Electronic portal imaging devices (EPIDs) based on indirect detection, active matrix flat panel imagers (AMFPIs) have become the technology of choice for geometric verification of patient localization and dose delivery in external beam radiotherapy. However, current AMFPI EPIDs, which are based on powdered-phosphor screens, make use of only approximately 2% of the incident radiation, thus severely limiting their imaging performance as quantified by the detective quantum efficiency (DQE) (approximately 1%, compared to approximately 75% for kilovoltage AMFPIs). With the rapidly increasing adoption of image-guided techniques in virtually every aspect of radiotherapy, there exist strong incentives to develop high-DQE megavoltage x-ray imagers, capable of providing soft-tissue contrast at very low doses in megavoltage tomographic and, potentially, projection imaging. In this work we present a systematic theoretical and preliminary empirical evaluation of a promising, high-quantum-efficiency, megavoltage x-ray detector design based on a two-dimensional matrix of thick, optically isolated, crystalline scintillator elements. The detector is coupled with an indirect detection-based active matrix array, with the center-to-center spacing of the crystalline elements chosen to match the pitch of the underlying array pixels. Such a design enables the utilization of a significantly larger fraction of the incident radiation (up to 80% for a 6 MV beam), through increases in the thickness of the crystalline elements, without loss of spatial resolution due to the spread of optical photons. Radiation damage studies were performed on test samples of two candidate scintillator materials, CsI(Tl) and BGO, under conditions relevant to radiotherapy imaging. A detailed Monte Carlo-based study was performed in order to examine the signal, spatial spreading, and noise properties of the absorbed energy for several segmented detector configurations. Parameters studied included scintillator

  9. Photonic crystals: A novel approach to enhance the light output of scintillation based detectors

    CERN Document Server

    Knapitsch, A; Leclercq, J L; Letartre, X; Auffray, E; Fabjan, C W

    2011-01-01

    Future high-energy physics (HEP) experiments as well as next generation medical imaging applications are more and more pushing towards better scintillation characteristics. One of the problems in heavy scintillating materials is related to their high electronic density, resulting in a large index of refraction. As a consequence, most of the scintillation light produced in the bulk material is trapped inside the crystal due to total internal reflection. The same problem also occurs with light emitting diodes (LEDs) and has for a long time been considered as a limiting factor for their overall efficiency. Recent studies have shown that those limits can be overcome by means of light scattering effects of photonic crystals (PhCs). In our simulations we could show light yield improvements between 90\\% and 110\\% when applying PhC structures to different scintillator materials. To evaluate the results, a PhC modified scintillator was produced in cooperation with the NIL (Nanotechnology Institute of Lyon). By using s...

  10. Development of InP solid state detector and liquid scintillator containing metal complex for measurement of pp/7Be solar neutrinos and neutrinoless double beta decay

    Science.gov (United States)

    Fukuda, Yoshiyuki; Moriyama, Shigetaka

    2012-07-01

    A large volume solid state detector using a semi-insulating Indium Phosphide (InP) wafer have been developed for measurement of pp/7Be solar neutrinos. Basic performance such as the charge collection efficiency and the energy resolution were measured by 60% and 20%, respectively. In order to detect two gammas (115keV and 497keV) from neutrino capture, we have designed hybrid detector which consist InP detector and liquid xenon scintillator for IPNOS experiment. New InP detector with thin electrode (Cr 50Å- Au 50Å). For another possibility, an organic liquid scintillator containing indium complex and zirconium complex were studied for a measurement of low energy solar neutrinos and neutrinosless double beta decay, respectively. Benzonitrile was chosen as a solvent because of good solubility for the quinolinolato complexes (2 wt%) and of good light yield for the scintillation induced by gamma-ray irradiation. The photo-luminescence emission spectra of InQ3 and ZrQ4 in benzonitrile was measured and liquid scintillator cocktail using InQ3 and ZrQ4 (50mg) in benzonitrile solutions (20 mL) with secondary scintillators with PPO (100mg) and POPOP (10mg) was made. The energy spectra of incident gammas were measured, and they are first results of the gamma-ray energy spectra using luminescent of metal complexes.

  11. Lens coupled scintillating screen-CCD X-ray area detector with a high detective quantum efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Koch, Andreas (Detector Group, Experiments Division, European Synchrotron Radiation Facility, B.P. 220, 38043 Grenoble (France))

    1994-09-01

    An X-ray area detector consisting essentially of a scintillating screen, a fast objective and a cooled 1242x1152 slow scan CCD camera is described. A detective quantum efficiency (DQE) of >0.3 for a planar field of view of arnothing110 mm and photon energies between 10 and 20 keV is obtainable at integrated intensity levels above 10[sup 8] eV/mm[sup 2]/readout without any image intensification. At lower intensities the readout noise of the CCD camera (8 e[sup -]/pixel) deteriorates the DQE. The spatial resolution of the detector is 100 [mu]m (FWHM) and the dynamic range 10[sup 4]. The design easily allows the exchange of screens in order to optimize the detector at other photon energies. The performance of the detector will be discussed in terms of DQE, dynamic range, spatial resolution, spatial distortion and uniformity of response. The detector will be initially used for small angle scattering and diffraction experiments as part of the Microfocus Beamline at the European Synchrotron Radiation Facility (ESRF). ((orig.))

  12. Fiber optically coupled radioluminescence detectors: A short review of key strengths and weaknesses of BCF-60 and Al2O3:C scintillating-material based systems in radiotherapy dosimetry applications

    DEFF Research Database (Denmark)

    Buranurak, Siritorn; Andersen, Claus E.

    2017-01-01

    Radiotherapy technologies have improved for several decades aiming to effectively destroy cancerous tissues without overdosing surrounding healthy tissues. In order to fulfil this requirement, accurate and precise dosimetry systems play an important role. Throughout the years, ionization chambers...... by radiation-induced generation of radioluminescence from a sub-mm size organic/inorganic phosphor. A thin optical fiber cable is used for guiding the radioluminescence to a photomultiplier tube or similar sensitive light detection systems. The measured light intensity is proportional to dose rate. Throughout...... the years, developments and research of the fiber detector systems have undergone in several groups worldwide. In this article, the in-house developed fiber detector systems based on two luminescence phosphors of (i) BCF-60 polystyrene-based organic plastic scintillator and (ii) carbon-doped aluminum oxide...

  13. Proposal of a Novel Setup for Linac Monitoring Using a Specifically Designed Plastic Scintillator and a Spectrophotometer

    Directory of Open Access Journals (Sweden)

    F. Moreno-Barbosa

    2016-08-01

    Full Text Available In this work we report the design, implementation and results of an alternative monitoring system for a linear accelerator (LINAC used in medical therapy. The system proposed consist in as lab of scintillator plastic with a wavelength shifter fiberoptically coupled to collect the light generated,and a Spectrophotometer Ocean Optics USB4000 as analyzer. The control was made with two computers, one into the therapy room and another, using a VNC (Virtual Network Computer and Ethernet wire, outside of the room in order to avoid radiation exposure. The LINAC dose range covered was 1, 2, 3, 4, 5, 10, 20, 30 and 40 Monitor Units (MU with 6 and 18 MeV energy photons. The spectrum obtained was compared with the measures of the LINAC ionization camera used to calibrate it. The results obtained allow us to propose this device as an alternative method to monitor the LINAC performance.

  14. Study and simulation of the read-out electronics design for a high-resolution plastic scintillating fiber based hodoscope

    Science.gov (United States)

    Blasco, José María; Sanchis, E.; Granero, D.; Martín, J. D.; González, V.; Sanchis-Sánchez, E.

    2015-06-01

    This work presents the study and simulation of a high-resolution charged particle detection device for beam positioning, monitoring and calibration, together with its read-out proposal. To provide the precise positional information of the beam, the detection system has been based on Plastic Scintillating Fibers (PSF), while the read-out on a Silicon-PhotoDiode (Si-PD) array. To carry out the study, a PSF prototype with one detection plane has been experimentally tested with a β particle source. Besides, Monte Carlo simulations of the complete system have also been conducted. Both simulations and experimental tests give consistency to the results obtained. The work presented in this article show the usefulness of this proposal for high-precision charged particle positioning, achieving resolutions up to 100 μm.

  15. SU-C-201-01: Investigation of the Effects of Scintillator Surface Treatment On Light Output Measurements with SiPM Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Valenciaga, Y; Prout, D; Chatziioannou, A [University of California, Los Angeles (UCLA) (United States)

    2015-06-15

    Purpose: To examine the effect of different scintillator surface treatments (BGO crystals) on the fraction of scintillation photons that exit the crystal and reach the photodetector (SiPM). Methods: Positron Emission Tomography is based on the detection of light that exits scintillator crystals, after annihilation photons deposit energy inside these crystals. A considerable fraction of the scintillation light gets trapped or absorbed after going through multiple internal reflections on the interfaces surrounding the crystals. BGO scintillator crystals generate considerably less scintillation light than crystals made of LSO and its variants. Therefore, it is crucial that the small amount of light produced by BGO exits towards the light detector. The surface treatment of scintillator crystals is among the factors affecting the ability of scintillation light to reach the detectors. In this study, we analyze the effect of different crystal surface treatments on the fraction of scintillation light that is detected by the solid state photodetector (SiPM), once energy is deposited inside a BGO crystal. Simulations were performed by a Monte Carlo based software named GATE, and validated by measurements from individual BGO crystals coupled to Philips digital-SiPM sensor (DPC-3200). Results: The results showed an increment in light collection of about 4 percent when only the exit face of the BGO crystal, is unpolished; compared to when all the faces are polished. However, leaving several faces unpolished caused a reduction of at least 10 percent of light output when the interaction occurs as far from the exit face of the crystal as possible compared to when it occurs very close to the exit face. Conclusion: This work demonstrates the advantages on light collection from leaving unpolished the exit face of BGO crystals. The configuration with best light output will be used to obtain flood images from BGO crystal arrays coupled to SiPM sensors.

  16. Evaluation of phase bunching in the central region of a cyclotron by a radial probe with a plastic scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Miyawaki, Nobumasa, E-mail: miyawaki.nobumasa@jaea.go.jp [Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan); Fukuda, Mitsuhiro [Research Center for Nuclear Physics, Osaka University, 10-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Kurashima, Satoshi; Kashiwagi, Hirotsugu; Okumura, Susumu [Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan); Arakawa, Kazuo [Gunma University Heavy Ion Medical Center, Gunma University, 3-39-22 Showa-Machi, Maebashi, Gunma, 371-8511 (Japan); Kamiya, Tomihiro [Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan)

    2014-12-11

    A new technique for evaluating the phase bunching performance in the central region of a cyclotron was developed. A newly-developed radial probe with a 6-mm-wide, 5-mm-height plastic scintillator was applied to analysis of the correlation between the internal beam phase distribution and the initial beam phase, defined by adjusting the relative RF phase of the beam buncher. The phase distribution measurement system, comprising the radial probe equipped with a plastic scintillator and the signal-processing modules, had a sufficiently good time resolution of 45 ps full-width at half-maximum for the phase bunching evaluation. The correlations between the buncher phase and the measured phase distribution for the acceleration harmonic number h=1 and 2 were consistent with the calculation result of the geometric trajectory analysis. For h=1 case of a 107 MeV {sup 4}He{sup 2+} beam, the internal beam phase region spread over 71 RF degrees full-width at quarter-maximum (FWQM) for the acceptable buncher phase region of 48 RF degrees, and no evidence of the phase bunching effect was observed. For h=2 case of a 260 MeV {sup 20}Ne{sup 7+} beam, the internal beam phase region for the acceptable buncher phase region of 59 RF degrees was compressed into 21 RF degrees FWQM. The phase bunching effect was sharply evident for h=2, and contributed to increase of the acceptable beam phase region and the beam intensity per phase width.

  17. Radiation detector developments in medical applications: inorganic scintillators in positron emission tomography.

    Science.gov (United States)

    van Eijk, Carel W E

    2008-01-01

    In recent years, a number of new gamma-ray scintillators are commercially available. These scintillators are either derived from known scintillators, e.g. Lu1-xYxAlO3: Ce (LuYAP) from LuAlO3:Ce and Lu(2(1-x))Y2xSiO5:Ce (LYSO) from Lu2SiO5:Ce or are the result of new discoveries, e.g. LaCl3:Ce and LaBr3:Ce. The first two materials are primarily of interest because of the relatively high detection efficiency and fast response; LYSO has found application in time-of-flight (TOF) positron-emission tomography (TOF PET) and the LuYAP-LYSO combination is used in small-animal PET. The halide scintillators have an excellent energy resolution of approximately 3% at 662 keV and they have a relatively high light yield. LaBr3:Ce is being studied for application in TOF PET. At the same time, the search for and research on new scintillator materials are going on. For example, LuI3:Ce is a new material with a very high light yield (approximately 90,000 photons MeV(-1)). Other examples of new materials are (C6H13NH3)2PbI4 and (C3H7NH3)2PbBr4, organic-inorganic hybrid compounds, of which the former has a very fast sub-nanosecond response. The new scintillators show great promise for new developments in medical applications, in particular, for PET systems.

  18. Development of time-of-flight neutron detector with fast-decay and low-afterglow scintillator for fast ignition experiment

    Directory of Open Access Journals (Sweden)

    Nagai T.

    2013-11-01

    Full Text Available A fast-decay and low-afterglow liquid scintillator was developed for the fast ignition experiment at the Institute of Laser Engineering (ILE. The liquid scintillator was coupled to a gated photomultiplier (PMT, and the gating performance under high-intensity γ-rays was experimentally checked. In 2010, a detector with a high detection efficiency of 10−4 was developed and installed in this experiment. The neutron yield in the fast heating experiment was successfully measured using this detector.

  19. Tl2LaCl5:Ce, high performance scintillator for gamma-ray detectors

    Science.gov (United States)

    Hawrami, R.; Ariesanti, E.; Wei, H.; Finkelstein, J.; Glodo, J.; Shah, K. S.

    2017-10-01

    This paper reports on a new Ce-doped Tl-based scintillator, Tl2LaCl5 (TLC), for gamma-ray detection. 10 mm diameter crystals have been successfully grown using the vertical Bridgman method. The emission peak of TLC is detected at 383 nm under X-ray excitation. The light yield of TLC is 76,000 ph/MeV. The samples show excellent energy resolution of 3.4% (FWHM) at 662 keV. The non-proportionality is less than 1%, from 32 keV to 1275 keV. The major scintillation decay time is 36 ns.

  20. SPORT: A new sub-nanosecond time-resolved instrument to study swift heavy ion-beam induced luminescence - Application to luminescence degradation of a fast plastic scintillator

    Science.gov (United States)

    Gardés, E.; Balanzat, E.; Ban-d'Etat, B.; Cassimi, A.; Durantel, F.; Grygiel, C.; Madi, T.; Monnet, I.; Ramillon, J.-M.; Ropars, F.; Lebius, H.

    2013-02-01

    We developed a new sub-nanosecond time-resolved instrument to study the dynamics of UV-visible luminescence under high stopping power heavy ion irradiation. We applied our instrument, called SPORT, on a fast plastic scintillator (BC-400) irradiated with 27-MeV Ar ions having high mean electronic stopping power of 2.6 MeV/μm. As a consequence of increasing permanent radiation damages with increasing ion fluence, our investigations reveal a degradation of scintillation intensity together with, thanks to the time-resolved measurement, a decrease in the decay constant of the scintillator. This combination indicates that luminescence degradation processes by both dynamic and static quenching, the latter mechanism being predominant. Under such high density excitation, the scintillation deterioration of BC-400 is significantly enhanced compared to that observed in previous investigations, mainly performed using light ions. The observed non-linear behaviour implies that the dose at which luminescence starts deteriorating is not independent on particles' stopping power, thus illustrating that the radiation hardness of plastic scintillators can be strongly weakened under high excitation density in heavy ion environments.