WorldWideScience

Sample records for plastic artificial cornea

  1. Property-based design: optimization and characterization of polyvinyl alcohol (PVA) hydrogel and PVA-matrix composite for artificial cornea.

    Science.gov (United States)

    Jiang, Hong; Zuo, Yi; Zhang, Li; Li, Jidong; Zhang, Aiming; Li, Yubao; Yang, Xiaochao

    2014-03-01

    Each approach for artificial cornea design is toward the same goal: to develop a material that best mimics the important properties of natural cornea. Accordingly, the selection and optimization of corneal substitute should be based on their physicochemical properties. In this study, three types of polyvinyl alcohol (PVA) hydrogels with different polymerization degree (PVA1799, PVA2499 and PVA2699) were prepared by freeze-thawing techniques. After characterization in terms of transparency, water content, water contact angle, mechanical property, root-mean-square roughness and protein adsorption behavior, the optimized PVA2499 hydrogel with similar properties of natural cornea was selected as a matrix material for artificial cornea. Based on this, a biomimetic artificial cornea was fabricated with core-and-skirt structure: a transparent PVA hydrogel core, surrounding by a ringed PVA-matrix composite skirt that composed of graphite, Fe-doped nano hydroxyapatite (n-Fe-HA) and PVA hydrogel. Different ratio of graphite/n-Fe-HA can tune the skirt color from dark brown to light brown, which well simulates the iris color of Oriental eyes. Moreover, morphologic and mechanical examination showed that an integrated core-and-skirt artificial cornea was formed from an interpenetrating polymer network, no phase separation appeared on the interface between the core and the skirt.

  2. An active artificial cornea with the function of inducing new corneal tissue generation in vivo-a new approach to corneal tissue engineering

    International Nuclear Information System (INIS)

    Huang Yaoxiong; Li Qinhua

    2007-01-01

    An active artificial cornea which can perform the function of inducing new cornea generation in vivo but does not need culture cells in vitro and which has similar optical and mechanical properties to those of the human cornea was constructed. An animal keratoplasty experiment using the artificial cornea as the implant showed that the animals' corneas could keep smooth surface and clear stroma postoperatively, and that the repopulation of the host's keratocytes, the degradation of the implant and new corneal tissue generation were completed at 5-6 months after surgery. Such an artificial cornea has several advantages over other corneal equivalents constructed in the typical way of tissue engineering: in having similar mechanical and optical properties to those of the human cornea and with no exogenetic cells, it can be used universally in different implantation surgeries without immunoreaction; it is easy to prepare and process into different shapes and sizes on a large scale, and suitable for long-distance transportation and long-term storage. All these characteristics make it a new approach to cornea tissue engineering having potential in many clinical applications

  3. Moorfields technique of donor cornea mounting for femtosecond-assisted keratoplasty: use of viscoelastic in the artificial anterior chamber.

    Science.gov (United States)

    Iovieno, Alfonso; Chowdhury, Vivek; Stevens, Julian D; Maurino, Vincenzo

    2012-07-01

    Appropriate mounting and cutting of the donor sclero-corneal cap is often cumbersome during femtosecond laser-assisted keratoplasty. The authors describe a technique for donor cornea femtosecond laser cutting using ophthalmic viscoelastic devices. The donor sclero-corneal cap is mounted on the artificial anterior chamber using a dispersive ophthalmic viscoelastic device instead of saline solution. The chances of artificial anterior chamber pressure loss, inadequate applanation, and fluid leaks are consistently reduced with the use of dispersive ophthalmic viscoelastic devices. The speed of donor femtosecond laser cutting is increased. The viscosity and elasticity of dispersive ophthalmic viscoelastic devices greatly assist the procedure with regard to ease of applanation, corneal endothelium protection, and decreased distortion of the applanated cornea. Copyright 2012, SLACK Incorporated.

  4. Facts about the Cornea and Corneal Disease

    Science.gov (United States)

    ... most used keratoprosthesis. It is made of clear plastic and consists of three parts, with donor cornea ... that, if successful, will lead to a significant reduction in the transmission of HSV to the cornea. ...

  5. Biocompatibility of a fish scale-derived artificial cornea: Cytotoxicity, cellular adhesion and phenotype, and in vivo immunogenicity.

    Science.gov (United States)

    van Essen, T H; van Zijl, L; Possemiers, T; Mulder, A A; Zwart, S J; Chou, C-H; Lin, C C; Lai, H J; Luyten, G P M; Tassignon, M J; Zakaria, N; El Ghalbzouri, A; Jager, M J

    2016-03-01

    To determine whether a fish scale-derived collagen matrix (FSCM) meets the basic criteria to serve as an artificial cornea, as determined with in vitro and in vivo tests. Primary corneal epithelial and stromal cells were obtained from human donor corneas and used to examine the (in)direct cytotoxicity effects of the scaffold. Cytotoxicity was assessed by an MTT assay, while cellular proliferation, corneal cell phenotype and adhesion markers were assessed using an EdU-assay and immunofluorescence. For in vivo-testing, FSCMs were implanted subcutaneously in rats. Ologen(®) Collagen Matrices were used as controls. A second implant was implanted as an immunological challenge. The FSCM was implanted in a corneal pocket of seven New Zealand White rabbits, and compared to sham surgery. The FSCM was used as a scaffold to grow corneal epithelial and stromal cells, and displayed no cytotoxicity to these cells. Corneal epithelial cells displayed their normal phenotypical markers (CK3/12 and E-cadherin), as well as cell-matrix adhesion molecules: integrin-α6 and β4, laminin 332, and hemi-desmosomes. Corneal stromal cells similarly expressed adhesion molecules (integrin-α6 and β1). A subcutaneous implant of the FSCM in rats did not induce inflammation or sensitization; the response was comparable to the response against the Ologen(®) Collagen Matrix. Implantation of the FSCM in a corneal stromal pocket in rabbits led to a transparent cornea, healthy epithelium, and, on histology, hardly any infiltrating immune cells. The FSCM allows excellent cell growth, is not immunogenic and is well-tolerated in the cornea, and thus meets the basic criteria to serve as a scaffold to reconstitute the cornea. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Dynamic Sensing of Cornea Deformation during an Air Puff

    Science.gov (United States)

    Yamada, Kenji; Yamasaki, Naoyuki; Gosho, Takumi; Kiuchi, Yoshiaki; Takenaka, Jouji; Higashimori, Mitsuru; Kaneko, Makoto

    In early diagnosis of glancoma, intraocular pressure measurement is one of an important method. Non-contact method has measured eye pressure through the deformation of cornea during the increase of the force due to air puff. The deformation is influenced by the cornea stiffness as well as the eye internal pressure. Since the cornea stiffness is unknown in general, it is difficult to evaluate the ture eye pressure. The dynamic behavior of cornea under air puff may provide us with a good hint for evaluating the cornea stiffness appropriately. For this purpose, we develop the sensing system composed of a high speed camera, a mirror for producing a virtual camera, a non-contact tonometer and a slit light source. This system enables us to measure the cornea deformation under concave shape. We show the experimental data for human eyes as well as an artificial eye made by transparent material.

  7. Nucleation and growth of apatite on NaOH-treated PEEK, HDPE and UHMWPE for artificial cornea materials.

    Science.gov (United States)

    Pino, M; Stingelin, N; Tanner, K E

    2008-11-01

    The skirt of an artificial cornea must integrate the implant to the host sclera, a major failure of present devices. Thus, it is highly desirable to encourage the metabolic activity of the cornea by using more bioactive, flexible skirt materials. Here we describe attempts to increase the bioactivity of polyether ether ketone (PEEK), high-density polyethylene (HDPE) and ultra-high molecular weight polyethylene (UHMWPE) films. The effectiveness of different strength NaOH pre-treatments to initiate apatite deposition on PEEK, HDPE and UHMWPE is investigated. We find that exposure of PEEK, HDPE and UHMWPE films to NaOH solutions induces the formation of potential nuclei for apatite (calcium phosphate), from which the growth of an apatite coating is stimulated when subsequently immersing the polymer films in 1.5 strength Simulated Body Fluid (SBF). As immersion time in SBF increases, further nucleation and growth produces a thicker and more compact apatite coating that can be expected to be highly bioactive. Interestingly, the apatite growth is found to also be dependent on both the concentration of NaOH solution and the structure of the polymer surface.

  8. Moisture Sorption in Artificially aged wood-plastic composites

    Science.gov (United States)

    B. Kristoffer Segerholm; Rebecca E. Ibach; Magnus E.P. Wålinder

    2012-01-01

    Moisture sorption in wood-plastic composites (WPCs) affects their durability and dimensional stability. In certain outdoor exposures, the moisture properties of WPCs are altered due to e.g. cracks induced by swelling and shrinkage of the components, as well as UV degradation or biological attack. The aim of this work was to study the effect of different artificial...

  9. Optical properties of an anterior lamellar human cornea model based on fibrin-agarose

    Science.gov (United States)

    Ionescu, Ana M.; Cardona, Juan de la Cruz; Ghinea, Razvan; Garzón, Ingrid; González-Andrades, Miguel; Alaminos, Miguel; Pérez, Maria del Mar

    2017-08-01

    The optical evaluation carried out using the Inverse Adding-Doubling (IAD) method to determine the scattering and the absorption coefficients of the bioengineered human corneal stromas showed that this type of artificial biomaterials shared many similarities with native control cornea after four weeks of development in culture. Their absorption and reduced scattering coefficients values were higher than the ones of the control cornea, but their spectral behaviors of both coefficients were similar. Time of development in culture was an influencing factor on the results.

  10. Diffusion of protein through the human cornea.

    Science.gov (United States)

    Charalel, Resmi A; Engberg, Kristin; Noolandi, Jaan; Cochran, Jennifer R; Frank, Curtis; Ta, Christopher N

    2012-01-01

    To determine the rate of diffusion of myoglobin and bovine serum albumin (BSA) through the human cornea. These small proteins have hydrodynamic diameters of approximately 4.4 and 7.2 nm, and molecular weights of 16.7 and 66 kDa, for myoglobin and BSA, respectively. Diffusion coefficients were measured using a diffusion chamber where the protein of interest and balanced salt solution were in different chambers separated by an ex vivo human cornea. Protein concentrations in the balanced salt solution chamber were measured over time. Diffusion coefficients were calculated using equations derived from Fick's law and conservation of mass in a closed system. Our experiments demonstrate that the diffusion coefficient of myoglobin is 5.5 ± 0.9 × 10(-8) cm(2)/s (n = 8; SD = 1.3 × 10(-8) cm(2)/s; 95% CI: 4.6 × 10(-8) to 6.4 × 10(-8) cm(2)/s) and the diffusion coefficient of BSA is 3.1 ± 1.0 × 10(-8) cm(2)/s (n = 8; SD = 1.4 × 10(-8) cm(2)/s; 95% CI: 2.1 × 10(-8) to 4.1 × 10(-8) cm(2)/s). Our study suggests that molecules as large as 7.2 nm may be able to passively diffuse through the human cornea. With applications in pharmacotherapy and the development of an artificial cornea, further experiments are warranted to fully understand the limits of human corneal diffusion and its clinical relevance. Copyright © 2012 S. Karger AG, Basel.

  11. Collagen immobilized PVA hydrogel-hydroxyapatite composites prepared by kneading methods as a material for peripheral cuff of artificial cornea

    International Nuclear Information System (INIS)

    Kobayashi, Hisatoshi; Kato, Masabumi; Taguchi, Tetsushi; Ikoma, Toshiyuki; Miyashita, Hideyuki; Shimmura, Shigeto; Tsubota, Kazuo; Tanaka, Junzo

    2004-01-01

    In order to achieve the firm fixation of the artificial cornea to host tissues, composites of collagen-immobilized poly(vinyl alcohol) hydrogel with hydroxyapatite were synthesized by a hydroxyapatite particles kneading method. The preparation method, characterization, and the results of corneal cell adhesion and proliferation on the composite material were studied. PVA-COL-HAp composites were successfully synthesized. A micro-porous structure of the PVA-COL-HAp could be introduced by hydrochloric acid treatment and the porosity could be controlled by the pH of the hydrochloric acid solution, the treatment time, and the crystallinity of the HAp particles. Chick embryonic keratocyto-like cells were well attached and proliferated on the PVA-COL-HAp composites. This material showed potential for keratoprosthesis application. Further study such as a long-term animal study is now required

  12. A Raman scattering and FT-IR spectroscopic study on the effect of the solar radiation in Antarctica on bovine cornea

    Science.gov (United States)

    Yamamoto, Tatsuyuki; Murakami, Naoki; Yoshikiyo, Keisuke; Takahashi, Tetsuya; Yamamoto, Naoyuki

    2010-01-01

    The Raman scattering and FT-IR spectra of the corneas, transported to the Syowa station in Antarctica and exposed to the solar radiation of the mid-summer for four weeks, were studied to reveal that type IV collagen involved in corneas were fragmented. The amide I and III Raman bands were observed at 1660 and 1245 cm -1, respectively, and the amide I and II infrared bands were observed at 1655 and 1545 cm -1, respectively, for original corneas before exposure. The background of Raman signals prominently increased and the ratio of amide II infrared band versus amide I decreased by the solar radiation in Antarctica. The control experiment using an artificial UV lamp was also performed in laboratory. The decline rate of the amide II/amide I was utilized for estimating the degree of fragmentation of collagen, to reveal that the addition of vitamin C suppressed the reaction while the addition of sugars promoted it. The effect of the solar radiation in Antarctica on the corneas was estimated as the same as the artificial UV lamp of four weeks (Raman) or one week (FT-IR) exposure.

  13. On the relationships between generative encodings, regularity, and learning abilities when evolving plastic artificial neural networks.

    Directory of Open Access Journals (Sweden)

    Paul Tonelli

    Full Text Available A major goal of bio-inspired artificial intelligence is to design artificial neural networks with abilities that resemble those of animal nervous systems. It is commonly believed that two keys for evolving nature-like artificial neural networks are (1 the developmental process that links genes to nervous systems, which enables the evolution of large, regular neural networks, and (2 synaptic plasticity, which allows neural networks to change during their lifetime. So far, these two topics have been mainly studied separately. The present paper shows that they are actually deeply connected. Using a simple operant conditioning task and a classic evolutionary algorithm, we compare three ways to encode plastic neural networks: a direct encoding, a developmental encoding inspired by computational neuroscience models, and a developmental encoding inspired by morphogen gradients (similar to HyperNEAT. Our results suggest that using a developmental encoding could improve the learning abilities of evolved, plastic neural networks. Complementary experiments reveal that this result is likely the consequence of the bias of developmental encodings towards regular structures: (1 in our experimental setup, encodings that tend to produce more regular networks yield networks with better general learning abilities; (2 whatever the encoding is, networks that are the more regular are statistically those that have the best learning abilities.

  14. Comparison of endothelial cell density of organ cultured corneas with cornea donor study.

    Science.gov (United States)

    Campolmi, Nelly; He, Zhiguo; Acquart, Sophie; Trone, Marie-Caroline; Bernard, Aurélien; Gauthier, Anne-Sophie; Garraud, Olivier; Forest, Fabien; Péocʼh, Michel; Gain, Philippe; Thuret, Gilles

    2014-06-01

    Determination of the endothelial cell density (ECD) by eye banks is paramount in donor cornea qualification. Unbiased measurement avoids wastage and grafts with an increased risk of premature failure. Internal calibration of the counting method is essential, but external validation would add an extra stage in the assessment of reliability. In this respect, data published by the multicenter Cornea Donor Study (CDS) in 2005 is a reference. The aim of the study was to compare ECD determined within a single eye bank, which uses calibrated image analysis software designed for transmitted light microscopy images of organ cultured corneas, with the CDS data determined on specular microscopy images of corneas stored at 4°C. ECD of consecutive corneas retrieved between 2005 and 2013 was determined after exposure to 0.9% NaCl. More than 300 ECs were counted on 3 fields of the central 8 mm. Endothelial cell boundaries were automatically drawn and verified by a skilled technician who performed all necessary corrections. Three thousand fifty-two corneas were analyzed, of which 48.5% donors were >75 years (CDS upper age limit). Between 10 and 75 years, the ECD varied according to donor age exactly in the same manner as in the CDS, but were consistently higher of 100 ± 25 cells per square millimeter (P Atlantic Ocean could be due to (1) differences in counting principles and/or (2) higher shrinkage of the cornea caused by stromal edema in organ culture.

  15. Artificial organs: recent progress in artificial hearing and vision.

    Science.gov (United States)

    Ifukube, Tohru

    2009-01-01

    Artificial sensory organs are a prosthetic means of sending visual or auditory information to the brain by electrical stimulation of the optic or auditory nerves to assist visually impaired or hearing-impaired people. However, clinical application of artificial sensory organs, except for cochlear implants, is still a trial-and-error process. This is because how and where the information transmitted to the brain is processed is still unknown, and also because changes in brain function (plasticity) remain unknown, even though brain plasticity plays an important role in meaningful interpretation of new sensory stimuli. This article discusses some basic unresolved issues and potential solutions in the development of artificial sensory organs such as cochlear implants, brainstem implants, artificial vision, and artificial retinas.

  16. Rudolf Virchow's medical school dissertation on rheumatism and the cornea: overlooked tribute to the cornea in biomedical research.

    Science.gov (United States)

    Margo, Curtis E; Harman, Lynn E

    2015-02-01

    To critique Rudolf Virchow's medical school dissertation on rheumatism and the cornea and to determine whether it might have anticipated his remarkable career in medicine. Review of the English translation of Rudolf Virchow's de Rheumate Praesertim Corneae written in 1843. The dissertation was more than 7000 words long. Virchow considered rheumatism as an irritant disorder not induced by acid as traditionally thought but by albumin. He concluded that inflammation was secondary to a primary irritant and that the "seat" of rheumatism was "gelatinous" (connective) tissues, which included the cornea. He divided kerato-rheumatism into different varieties. The prognosis of keratitis was variable, and would eventually lapse into "scrofulosis, syphilis, or arthritis of the cornea." Virchow's dissertation characterizes rheumatism in terms of chemical and tissue interactions that make little sense in the context of today's knowledge of rheumatic disease and keratitis. Ironically, many of these concepts were made obsolete by the cellular model of disease that Virchow championed. Virchow decided to pursue the study of rheumatism through the cornea because he thought that the cornea was an ideal tissue to study disease. This discernment was passed on to his students whose seminal contributions to general pathology were based on research with the cornea. It is debatable whether Virchow's insight into the importance of the cornea in biomedical research at such an early stage of his career could have predicted his monumental contributions to medicine.

  17. Spherical aberrations of human astigmatic corneas.

    Science.gov (United States)

    Zhao, Huawei; Dai, Guang-Ming; Chen, Li; Weeber, Henk A; Piers, Patricia A

    2011-11-01

    To evaluate whether the average spherical aberration of human astigmatic corneas is statistically equivalent to human nonastigmatic corneas. Spherical aberrations of 445 astigmatic corneas prior to laser vision correction were retrospectively investigated to determine Zernike coefficients for central corneal areas 6 mm in diameter using CTView (Sarver and Associates). Data were divided into groups according to cylinder power (0.01 to 0.25 diopters [D], 0.26 to 0.75 D, 0.76 to 1.06 D, 1.07 to 1.53 D, 1.54 to 2.00 D, and >2.00 D) and according to age by decade. Spherical aberrations were correlated with age and astigmatic power among groups and the entire population. Statistical analyses were conducted, and P.05 for all tested groups). Mean spherical aberration of astigmatic corneas was not correlated significantly with cylinder power or age (P>.05). Spherical aberrations are similar to those of nonastigmatic corneas, permitting the use of these additional data in the design of aspheric toric intra-ocular lenses. Copyright 2011, SLACK Incorporated.

  18. Anatomy and physiology of the cornea.

    Science.gov (United States)

    DelMonte, Derek W; Kim, Terry

    2011-03-01

    The importance of the cornea to the ocular structure and visual system is often overlooked because of the cornea's unassuming transparent nature. The cornea lacks the neurobiological sophistication of the retina and the dynamic movement of the lens; yet, without its clarity, the eye would not be able to perform its necessary functions. The complexity of structure and function necessary to maintain such elegant simplicity is the wonder that draws us to one of the most important components of our visual system. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Customized Finite Element Modelling of the Human Cornea.

    Directory of Open Access Journals (Sweden)

    Irene Simonini

    Full Text Available To construct patient-specific solid models of human cornea from ocular topographer data, to increase the accuracy of the biomechanical and optical estimate of the changes in refractive power and stress caused by photorefractive keratectomy (PRK.Corneal elevation maps of five human eyes were taken with a rotating Scheimpflug camera combined with a Placido disk before and after refractive surgery. Patient-specific solid models were created and discretized in finite elements to estimate the corneal strain and stress fields in preoperative and postoperative configurations and derive the refractive parameters of the cornea.Patient-specific geometrical models of the cornea allow for the creation of personalized refractive maps at different levels of IOP. Thinned postoperative corneas show a higher stress gradient across the thickness and higher sensitivity of all geometrical and refractive parameters to the fluctuation of the IOP.Patient-specific numerical models of the cornea can provide accurate quantitative information on the refractive properties of the cornea under different levels of IOP and describe the change of the stress state of the cornea due to refractive surgery (PRK. Patient-specific models can be used as indicators of feasibility before performing the surgery.

  20. Serologic Evaluation of Cornea Donors and Microbiologic Evaluation of Cornea Storage Media in an Eye Bank from Izmir, Turkey.

    Science.gov (United States)

    Palamar, Melis; Degirmenci, Cumali; Sertoz, Ruchan; Aydemir, Sohret; Egrilmez, Sait; Yagci, Ayse

    2017-12-01

    Our objective was to evaluate the serologic positivity of cornea donors and microbiologic positivity of cornea storage media at the Ege University Tissue and Cornea Bank, Izmir, Turkey. We retrospectively investigated the serologic blood sample and microbiological culture media analysis results of all cornea donors at Ege University Tissue and Cornea Bank between 2007 and 2015 with reference to age, sex, and cause of death of each donor. Mean age of the 955 deceased donors was 43.19 ± 15.89 years (range, 2-65 y). The mean postmortem time to blood sample removal and excision of the cornea tissue was 8.4 hours (range, 4-12 h). Serologic analyses showed that 855 donors (89.5%) were seronegative. The remaining donors were seropositive for hepatitis B (54 donors; 5.7%), human immunodeficiency (27 donors; 2.8%), hepatitis C (14 donors; 1.5%), and syphilis (5 donors; 0.5%) virus infections. Microbiologic analyses of the storage media were negative, with no microorganisms shown in 855 samples (89.5%). Candida species (32 donors; 3.4%), Escherichia coli (14 donors; 1.5%), Pseudomonas aeruginosa (11 donors; 1.2%), methicillin-resistant Staphylococcus aureus (11 donors; 1.2%), Enterobacter species (11 donors; 1.2%), Klebsiella pneumoniae (7 donors; 0.7%), Acinetobacter baumannii (6 donors; 0.6%), Proteus species (5 donors; 0.5%), and Corynebacterium species (3 donors; 0.3%) were the detected microorganisms in the infected storage media. False-positive serologic results among cornea donors were high. The incidence of false-positive results might be decreased by earlier blood removal from deceased donors and testing of all potential donors in intensive care units. Although rare, endophthalmitis after keratoplasty might be a devastating problem. In addition to serologic testing, microbiologic analyses of cornea storage media before transplant may be an effective way to prevent postoperative infectious complications.

  1. Tissue Engineering the Cornea: The Evolution of RAFT

    Science.gov (United States)

    Levis, Hannah J.; Kureshi, Alvena K.; Massie, Isobel; Morgan, Louise; Vernon, Amanda J.; Daniels, Julie T.

    2015-01-01

    Corneal blindness affects over 10 million people worldwide and current treatment strategies often involve replacement of the defective layer with healthy tissue. Due to a worldwide donor cornea shortage and the absence of suitable biological scaffolds, recent research has focused on the development of tissue engineering techniques to create alternative therapies. This review will detail how we have refined the simple engineering technique of plastic compression of collagen to a process we now call Real Architecture for 3D Tissues (RAFT). The RAFT production process has been standardised, and steps have been taken to consider Good Manufacturing Practice compliance. The evolution of this process has allowed us to create biomimetic epithelial and endothelial tissue equivalents suitable for transplantation and ideal for studying cell-cell interactions in vitro. PMID:25809689

  2. Finite element analysis of blunt foreign body impact on the cornea after PRK and LASIK.

    Science.gov (United States)

    Mousavi, Seyed Jamaleddin; Nassiri, Nariman; Masoumi, Nafiseh; Nassiri, Nader; Majdi-N, Mercede; Farzaneh, Solmaz; Djalilian, Ali R; Peyman, Gholam A

    2012-01-01

    To investigate the effect of blunt foreign body impact on a human cornea after photorefractive keratectomy (PRK) and LASIK using a simulation model. Computational simulations were performed using a finite element analysis program (LS-Dyna, Livermore Software Technology Corp). The blunt foreign body was set to impact at the center of the corneal surface models (after PRK and LASIK) with thicknesses of 500, 450, 400, 350, and 300 μm. Corneal rupture was assumed to occur at a peak stress of 9.45 MPa and at a strain of 18%. The foreign body projectile was blunt in shape, made from aluminum, contained plastic-kinematic properties, and had a density of 2700 kg/m(3). The projectile was launched at the center of the cornea with velocities ranging from 20 to 60 m/s. The threshold of impact velocities creating rupture in corneal thicknesses of 500, 450, 400, 350, and 300 μm were 33, 32.8, 30.7, 27.9, and 22.8 m/s, respectively, in the PRK model. In the LASIK model, the thresholds creating rupture in the stromal bed of the corneas with thicknesses of 500, 450, 400, 350, and 300 μm were 40, 38.1, 35.6, 31.5, and 26.7 m/s, respectively. The 110-μm corneal flap in the LASIK model ruptured at all velocities. Ruptures occurred at lower velocities in the PRK cornea model than in the corneal stromal bed of the LASIK model following blunt foreign body impact. Copyright 2012, SLACK Incorporated.

  3. Finite element modelling of cornea mechanics: a review

    Directory of Open Access Journals (Sweden)

    Talisa Mohammad Nejad

    2014-01-01

    Full Text Available The cornea is a transparent tissue in front of the eye that refracts light and facilitates vision. A slight change in the geometry of the cornea remarkably affects the optical power. Because of this sensitivity, biomechanical study of the cornea can reveal much about its performance and function. In vivo and in vitro studies have been conducted to investigate the mechanics of the cornea and determine its characteristics. Numerical techniques such as the finite element method (FEM have been extensively implemented as effective and noninvasive methods for analyzing corneal mechanics and possible disorders. This article reviews the use of FEM for assessing the mechanical behavior of the cornea. Different applications of FEM in corneal disease studies, surgical predictions, impact simulations, and clinical applications have been reviewed. Some suggestions for the future of this type of modeling in the area of corneal mechanics are also discussed.

  4. New intraocular pressure measurement method using reflected pneumatic pressure from cornea deformed by air puff of ring-type nozzle.

    Science.gov (United States)

    Kim, Hyung Jin; Seo, Yeong Ho; Kim, Byeong Hee

    2017-01-01

    In this study, a non-contact type intraocular pressure (IOP) measuring system using reflected pneumatic pressure is proposed to overcome the disadvantages of existing measurement systems. A ring-type nozzle, a key component in the proposed system, is designed via computational fluid analysis. It predicts the reflected pneumatic pressure based on the nozzle exit angle and inner and outer diameters of the nozzle, which are 30°, 7 mm, and 9 mm, respectively. Performance evaluation is conducted using artificial eyes fabricated using polydimethylsiloxane with the specifications of human eyes. The IOP of the fabricated artificial eyes is adjusted to 10, 30, and 50 mm Hg, and the reflected pneumatic pressure is measured as a function of the distance between the ring-type nozzle and artificial eye. The measured reflected pneumatic pressure is high when the measurement distance is short and eye pressure is low. The cornea of an artificial eye is significantly deformed at a low IOP, and the applied pneumatic pressure is more concentrated in front of the ring-type nozzle because of the deformed cornea. Thus, the reflected pneumatic pressure at a low IOP has more inflows into the pressure sensor inserted inside the nozzle. The sensitivity of the output based on the IOP at measurement distances between 3-5 mm is -0.0027, -0.0022, -0.0018, -0.0015, and -0.0012. Sensitivity decreases as the measurement distance increases. In addition, the reflected pneumatic pressure owing to the misalignment at the measurement distances of 3-5 mm is not affected within a range of 0.5 mm. Therefore, the measurement range is acceptable up to a 1 mm diameter from the center of an artificial eye. However, the accuracy gradually decreases as the reflected pneumatic pressure from a misalignment of 1 mm or more decreases by 26% or more.

  5. [The 2009 performance report of the German cornea banks].

    Science.gov (United States)

    Schrage, N; Reinhard, T; Seitz, B; Hermel, M; Böhringer, D; Reinshagen, H

    2011-03-01

    In Germany, human tissue for corneal and amniotic transplantation is supplied by 27 cornea banks. The Section for Tissue Transplantation and Biotechnology of the German Ophthalmological Society records the cornea banks' activities by means of an annual questionnaire. In 2009, a total of 4,818 corneal grafts were processed by 21 responding cornea banks, and 57% were deemed suitable for transplantation. This ratio is slightly higher than the European average. In addition, German cornea banks released 1,257 amniotic grafts in 2009. German cornea banks are currently facing new regulatory issues due to updated legislation regarding tissue transplantation. Recent updates in European law have limited the cutoff time for postmortem blood sampling to 24 h, and this regulation may lead to a significant reduction in potential donors.

  6. Factors influencing the virological testing of cornea donors.

    Science.gov (United States)

    Röck, Tobias; Beck, Robert; Jürgens, Stefan; Bartz-Schmidt, Karl Ulrich; Bramkamp, Matthias; Thaler, Sebastian; Röck, Daniel

    2017-11-01

    To assess the influence of donor, environment, and logistical factors on the results of virological testing of blood samples from cornea donors.Data from 670 consecutive cornea donors were analyzed retrospectively. Logistic regression analysis was used to assess the influence of different factors on the results of virological testing of blood samples from cornea donors.The mean annual rate of donors with serology-reactive or not evaluable result was 14.8% (99 of 670) (range 11.9%-16.9%). The cause of donor death by cancer increased the risk of serology-reactive or not evaluable result (P = .0300). Prolonged time between death and post mortem blood removal was associated with a higher rate of serology-reactive or not evaluable result (P donors, sex, and donor age had no significant impact on the results of virological testing of blood samples from cornea donors.The cause of donor death by cancer and a prolonged time between death and post mortem blood removal seem to be mainly responsible for serology-reactive or not evaluable result of blood samples from cornea donors. The percentage of discarded corneas caused by serology-reactive or not evaluable result may be reduced by shortening the period of time between death and post mortem blood removal. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  7. A Mouse Model of the Cornea Pocket Assay for Angiogenesis Study

    Science.gov (United States)

    Tang, Zhongshu; Zhang, Fan; Li, Yang; Arjunan, Pachiappan; Kumar, Anil; Lee, Chunsik; Li, Xuri

    2011-01-01

    A normal cornea is clear of vascular tissues. However, blood vessels can be induced to grow and survive in the cornea when potent angiogenic factors are administered 1. This uniqueness has made the cornea pocket assay one of the most used models for angiogenesis studies. The cornea composes multiple layers of cells. It is therefore possible to embed a pellet containing the angiogenic factor of interest in the cornea to investigate its angiogenic effect 2,3. Here, we provide a step by step demonstration of how to (I) produce the angiogenic factor-containing pellet (II) embed the pellet into the cornea (III) analyze the angiogenesis induced by the angiogenic factor of interest. Since the basic fibroblast growth factor (bFGF) is known as one of the most potent angiogenic factors 4, it is used here to induce angiogenesis in the cornea. PMID:21876523

  8. GENDER AND AGE RELATED VARIATION IN CORNEA POWER

    African Journals Online (AJOL)

    2014-05-01

    May 1, 2014 ... population and how it varies with gender and age. Design: A .... horizontal in orientation. For the purpose of .... race as cornea curvature have been noted to exhibit ... Grosevenor, T. Role of Cornea in Emmetropia and. Myopia.

  9. ANALYSIS OF DONOR CORNEA RETRIEVAL DATA- HOSPITAL AND RESIDENCES

    Directory of Open Access Journals (Sweden)

    Rekha Gyanchand

    2017-07-01

    Full Text Available BACKGROUND The voluntary eye donation is still the most popular methods of eye donation in our country. Since last three decades, the voluntary eye donation is promoted by a number of NGOs and Government of India. The meaning of voluntary eye donation is that an individual has prior knowledge about eye donation and also has the contact number of the eye bank. When they come across any death in their community, they will contact the eye bank for eye donation. As per Eye Bank Association of India, the incidence of total blindness is 8.9 million and 1% of this is corneal blindness. Each year, 25,000 to 30,000/new corneal blind patients are added. The voluntary eye donation is not sufficient in providing transplantable corneas to the corneal blind. As our concentration is mainly on voluntary eye collections, this is one of the main reasons that we are unable reach our target of sight restoration in the management of corneal blindness. In this study, we have analysed the voluntary eye donations procured from residence and hospital. The aim of the study is to compare corneas procured by hospital eye donations and residence eye donations to look into all factors that contribute to a transplantable cornea. MATERIALS AND METHODS The donor corneas retrieved from the year 2005-2010 were analysed. The hospital eye donations and residential eye donations were divided into two study groups. The factors analysed were number of corneas collected, donor age and gender, serology test result, death to preservation time (DPT, optical grade cornea, utilisation of corneas for transplantation and role of pledging in eye donation. Study Type- Retrospective study. Study Done- At Lions International Eye Bank, Bangalore. RESULTS The total number of donor eyes collected from the year 2005-2010 were 7362 of which residence collections was 50.73% and hospital collections was 49.26%. The 5-year period between from 2005 to 2010 in spite of not conducting a Hospital Cornea

  10. T-style keratoprosthesis based on surface-modified poly (2-hydroxyethyl methacrylate) hydrogel for cornea repairs

    International Nuclear Information System (INIS)

    Xiang, Jun; Sun, Jianguo; Hong, Jiaxu; Wang, Wentao; Wei, Anji; Le, Qihua; Xu, Jianjiang

    2015-01-01

    Corneal disease is a common cause of blindness, and keratoplasty is considered as an effective treatment method. However, there is a severe shortage of donor corneas worldwide. This paper presents a novel T-style design of a keratoprosthesis and its preparation methods, in which a mechanically and structurally effective artificial cornea is made based on a poly(2-hydroxyethyl methacrylate) hydrogel. The porous skirt was modified with hyaluronic acid and cationized gelatin, and the bottom of the optical column was coated with poly(ethylene glycol). The physical properties of the T-style Kpro were analyzed using ultraviolet and visible spectrophotometry and electron scanning microscopy. The surface chemical properties were characterized using Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy. The surface modification in the spongy skirt promoted cell adhesion and produced a firm bond between the corneal tissue and the implant device, while the surface modification in the optic column resisted cell adhesion and prevented retroprosthetic membrane formation. Through improved surgical techniques, the novel T-style keratoprosthesis provides enough mechanical stability to facilitate long-term biointegration with the host environment. In vivo implantation experiments showed that the T-style keratoprosthesis is a promising cornea alternative for patients with severe limbal stem cell deficiency and corneal opacity. - Highlights: • T-style keratoprosthesis was designed and prepared based on a PHEMA hydrogel. • Selective surface modifications effectively regulated cells' selective adhesion. • T-style keratoprosthesis provides enough mechanical stability to facilitate long-term biointegration with host tissues

  11. T-style keratoprosthesis based on surface-modified poly (2-hydroxyethyl methacrylate) hydrogel for cornea repairs

    Energy Technology Data Exchange (ETDEWEB)

    Xiang, Jun [Department of Ophthalmology, Eye & ENT Hospital, Shanghai Medical College, Fudan University (China); Key Laboratory of Myopia, Ministry of Health, Fudan University (China); Shanghai Key Laboratory of Visual Impairment and Restoration, Fudan University (China); Sun, Jianguo [Research Center, Eye & ENT Hospital, Shanghai Medical College, Fudan University (China); Key Laboratory of Myopia, Ministry of Health, Fudan University (China); Shanghai Key Laboratory of Visual Impairment and Restoration, Fudan University (China); State Key Laboratory of Molecular Engineering of Polymers, Fudan University (China); Hong, Jiaxu [Department of Ophthalmology, Eye & ENT Hospital, Shanghai Medical College, Fudan University (China); Key Laboratory of Myopia, Ministry of Health, Fudan University (China); Shanghai Key Laboratory of Visual Impairment and Restoration, Fudan University (China); Wang, Wentao [Research Center, Eye & ENT Hospital, Shanghai Medical College, Fudan University (China); Key Laboratory of Myopia, Ministry of Health, Fudan University (China); Shanghai Key Laboratory of Visual Impairment and Restoration, Fudan University (China); Wei, Anji [Department of Ophthalmology, Eye & ENT Hospital, Shanghai Medical College, Fudan University (China); Key Laboratory of Myopia, Ministry of Health, Fudan University (China); Shanghai Key Laboratory of Visual Impairment and Restoration, Fudan University (China); Le, Qihua [Research Center, Eye & ENT Hospital, Shanghai Medical College, Fudan University (China); Key Laboratory of Myopia, Ministry of Health, Fudan University (China); Shanghai Key Laboratory of Visual Impairment and Restoration, Fudan University (China); Xu, Jianjiang, E-mail: jianjiang-xu@163.com [Department of Ophthalmology, Eye & ENT Hospital, Shanghai Medical College, Fudan University (China); Key Laboratory of Myopia, Ministry of Health, Fudan University (China); Shanghai Key Laboratory of Visual Impairment and Restoration, Fudan University (China)

    2015-05-01

    Corneal disease is a common cause of blindness, and keratoplasty is considered as an effective treatment method. However, there is a severe shortage of donor corneas worldwide. This paper presents a novel T-style design of a keratoprosthesis and its preparation methods, in which a mechanically and structurally effective artificial cornea is made based on a poly(2-hydroxyethyl methacrylate) hydrogel. The porous skirt was modified with hyaluronic acid and cationized gelatin, and the bottom of the optical column was coated with poly(ethylene glycol). The physical properties of the T-style Kpro were analyzed using ultraviolet and visible spectrophotometry and electron scanning microscopy. The surface chemical properties were characterized using Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy. The surface modification in the spongy skirt promoted cell adhesion and produced a firm bond between the corneal tissue and the implant device, while the surface modification in the optic column resisted cell adhesion and prevented retroprosthetic membrane formation. Through improved surgical techniques, the novel T-style keratoprosthesis provides enough mechanical stability to facilitate long-term biointegration with the host environment. In vivo implantation experiments showed that the T-style keratoprosthesis is a promising cornea alternative for patients with severe limbal stem cell deficiency and corneal opacity. - Highlights: • T-style keratoprosthesis was designed and prepared based on a PHEMA hydrogel. • Selective surface modifications effectively regulated cells' selective adhesion. • T-style keratoprosthesis provides enough mechanical stability to facilitate long-term biointegration with host tissues.

  12. Matrix metalloproteinase expression in excimer laser wounded rabbit corneas

    Science.gov (United States)

    Hahn, Taewon; Chamon, Wallace; Akova, Yonja; Stark, Walter J.; Stetler-Stevenson, William G.; Azar, Dimitri T.

    1994-06-01

    This study was performed to obtain information about matrix metalloproteinase (MMP) expression in excimer-wounded corneas and to determine whether MMPs expression correlates with the depth of the ablation. 6-mm excimer keratectomy (60 or 180 micrometers ) was performed using the 193-mm ArF excimer laser on 12 NZW rabbits. Corneas treated with mechanical epithelial debridement and untreated corneas served as controls. Rabbits were killed at 20 and 30 hr after laser ablation. Zymography after SDS extraction was performed on regenerated central epithelium and the central stroma to determine MMPs expression. We observed enzymatic activity of a 92 KDa band in the epithelium of excimer-ablated corneas but not in that following debridement wounds and untreated controls. The expression of the 92 KDa MMP was most pronounced with the deeper excimer ablation. A 72 KDa band of enzymatic activity present in the stroma of all treated and control eyes was also seen in the epithelium of excimer-ablated corneas. These proteolytic enzymes may play an important role in wound healing and remodelling after excimer keratectomy.

  13. File list: ALL.Oth.50.AllAg.Cornea [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Oth.50.AllAg.Cornea mm9 All antigens Others Cornea SRX437637,SRX437636,SRX24830...2,SRX248301,SRX437638 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/ALL.Oth.50.AllAg.Cornea.bed ...

  14. File list: ALL.Oth.05.AllAg.Cornea [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Oth.05.AllAg.Cornea mm9 All antigens Others Cornea SRX437637,SRX437636,SRX24830...2,SRX248301,SRX437638 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/ALL.Oth.05.AllAg.Cornea.bed ...

  15. File list: ALL.Oth.20.AllAg.Cornea [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Oth.20.AllAg.Cornea mm9 All antigens Others Cornea SRX437637,SRX437636,SRX24830...2,SRX248301,SRX437638 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/ALL.Oth.20.AllAg.Cornea.bed ...

  16. File list: ALL.Oth.10.AllAg.Cornea [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Oth.10.AllAg.Cornea mm9 All antigens Others Cornea SRX437637,SRX248302,SRX43763...6,SRX248301,SRX437638 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/ALL.Oth.10.AllAg.Cornea.bed ...

  17. Artificial neuron operations and spike-timing-dependent plasticity using memristive devices for brain-inspired computing

    Science.gov (United States)

    Marukame, Takao; Nishi, Yoshifumi; Yasuda, Shin-ichi; Tanamoto, Tetsufumi

    2018-04-01

    The use of memristive devices for creating artificial neurons is promising for brain-inspired computing from the viewpoints of computation architecture and learning protocol. We present an energy-efficient multiplier accumulator based on a memristive array architecture incorporating both analog and digital circuitries. The analog circuitry is used to full advantage for neural networks, as demonstrated by the spike-timing-dependent plasticity (STDP) in fabricated AlO x /TiO x -based metal-oxide memristive devices. STDP protocols for controlling periodic analog resistance with long-range stability were experimentally verified using a variety of voltage amplitudes and spike timings.

  18. Extracellular matrix alterations in human corneas with bullous keratopathy

    DEFF Research Database (Denmark)

    Ljubimov, A V; Burgeson, R E; Butkowski, R J

    1996-01-01

    PURPOSE. To uncover abnormalities of extracellular matrix (ECM) distribution in human corneas with pseudophakic and aphakic bullous keratopathy (PBK/ABK). METHODS. Indirect immunofluorescence with antibodies to 27 ECM components was used on frozen sections of 14 normal and 20 PBK/ABK corneas...... in some cases, correlated with decreased visual acuity. In normal central corneas, tenascin was never found. Other major ECM abnormalities in PBK/ABK corneas compared to normals included: discontinuous epithelial BM straining for laminin-1 (alpha 1 beta 1 gamma 1), entactin/nidogen and fibronectin......; accumulation of fibronectin and alpha 1-alpha 2 type IV collagen on the endothelial face of the Descemet's membrane; and abnormal deposition of stromal ECM (tenascin, fibronectin, decorin, types I, III, V, VI, VIII, XII, XIV collagen) and BM components (type IV, collagen, perlecan, bamacan, laminin-1, entactin...

  19. Pharmacokinetics of chlorhexidine gluconate 0.02% in the rabbit cornea.

    Science.gov (United States)

    Xuguang, Sun; Yanchuang, Liang; Feng, Zhang; Shiyun, Luo; Xiaotang, Yin

    2006-08-01

    The aim of this study was to determine the pharmacokinetic parameters of chlorhexidine gluconate (CHG) in the rabbit cornea. Each eye of 16 New Zealand white rabbits were topically instilled with 50 microL of CHG 0.02% eye drops twice with a 5-min interval. Four (4) corneas of 2 rabbits were harvested at each time point. The concentration of CHG in the cornea was determined with high-performance liquid chromatography (HPLC) and 387 software to simulate the pharmacokinetic parameters. The concentration of CHG in the cornea displayed an open two-compartment model. Tmax was 13.75 min, Cmax 0.713 microg.g1, clearance rate 1.64 microg.g-1.min-1, and t1/2alpha, t1/2beta, and t1/2ka was 2.65, 48.72, and 2.67 min, respectively. The concentration of CHG in the rabbit cornea could be determined by means of HPLC. The maximum concentration of CHG in the corneal tissue was much higher than the trophozoite minimum amoebicidal concentration (TMAC) in vitro.

  20. CORNEA AND ANTERIOR SEGMENT

    African Journals Online (AJOL)

    Yet, fewer than 150,000 corneal transplant surgeries are performed annually worldwide. Corneal blindness arises from a wide variety of causes, from mechanical, chemical, and radiation injury to microbial infections and corneal degenerative diseases. The use of human cadaver donor corneas has been limited by its often.

  1. Melatonin Entrains PER2::LUC Bioluminescence Circadian Rhythm in the Mouse Cornea

    Science.gov (United States)

    Baba, Kenkichi; Davidson, Alec J.; Tosini, Gianluca

    2015-01-01

    Purpose Previous studies have reported the presence of a circadian rhythm in PERIOD2::LUCIFERASE (PER2::LUC) bioluminescence in mouse photoreceptors, retina, RPE, and cornea. Melatonin (MLT) modulates many physiological functions in the eye and it is believed to be one of the key circadian signals within the eye. The aim of the present study was to investigate the regulation of the PER2::LUC circadian rhythm in mouse cornea and to determine the role played by MLT. Methods Corneas were obtained from PER2::LUC mice and cultured to measure bioluminescence rhythmicity in isolated tissue using a Lumicycle or CCD camera. To determine the time-dependent resetting of the corneal circadian clocks in response to MLT or IIK7 (a melatonin type 2 receptor, MT2, agonist) was added to the cultured corneas at different times of the day. We also defined the location of the MT2 receptor within different corneal layers using immunohistochemistry. Results A long-lasting bioluminescence rhythm was recorded from cultured PER2::LUC cornea and PER2::LUC signal was localized to the corneal epithelium and endothelium. MLT administration in the early night delayed the cornea rhythm, whereas administration of MLT at late night to early morning advanced the cornea rhythm. Treatment with IIK7 mimicked the MLT phase-shifting effect. Consistent with these results, MT2 immunoreactivity was localized to the corneal epithelium and endothelium. Conclusions Our work demonstrates that MLT entrains the PER2::LUC bioluminescence rhythm in the cornea. Our data indicate that the cornea may represent a model to study the molecular mechanisms by which MLT affects the circadian clock. PMID:26207312

  2. The structural response of the cornea to changes in stromal hydration.

    Science.gov (United States)

    Hayes, Sally; White, Tomas; Boote, Craig; Kamma-Lorger, Christina S; Bell, James; Sorenson, Thomas; Terrill, Nick; Shebanova, Olga; Meek, Keith M

    2017-06-01

    The primary aim of this study was to quantify the relationship between corneal structure and hydration in humans and pigs. X-ray scattering data were collected from human and porcine corneas equilibrated with polyethylene glycol (PEG) to varying levels of hydration, to obtain measurements of collagen fibril diameter, interfibrillar spacing (IFS) and intermolecular spacing. Both species showed a strong positive linear correlation between hydration and IFS 2 and a nonlinear, bi-phasic relationship between hydration and fibril diameter, whereby fibril diameter increased up to approximately physiological hydration, H = 3.0, with little change thereafter. Above H = 3.0, porcine corneas exhibited a larger fibril diameter than human corneas ( p < 0.001). Intermolecular spacing also varied with hydration in a bi-phasic manner but reached a maximum value at a lower hydration ( H = 1.5) than fibril diameter. Human corneas displayed a higher intermolecular spacing than porcine corneas at all hydrations ( p < 0.0001). Human and porcine corneas required a similar PEG concentration to reach physiological hydration, suggesting that the total fixed charge that gives rise to the swelling pressure is the same. The difference in their structural responses to hydration can be explained by variations in molecular cross-linking and intra/interfibrillar water partitioning. © 2017 The Authors.

  3. Human Bone Derived Collagen for the Development of an Artificial Corneal Endothelial Graft. In Vivo Results in a Rabbit Model.

    Directory of Open Access Journals (Sweden)

    Natalia Vázquez

    Full Text Available Corneal keratoplasty (penetrating or lamellar using cadaveric human tissue, is nowadays the main treatment for corneal endotelial dysfunctions. However, there is a worldwide shortage of donor corneas available for transplantation and about 53% of the world's population have no access to corneal transplantation. Generating a complete cornea by tissue engineering is still a tough goal, but an endothelial lamellar graft might be an easier task. In this study, we developed a tissue engineered corneal endothelium by culturing human corneal endothelial cells on a human purified type I collagen membrane. Human corneal endothelial cells were cultured from corneal rims after corneal penetrating keratoplasty and type I collagen was isolated from remnant cancellous bone chips. Isolated type I collagen was analyzed by western blot, liquid chromatography -mass spectrometry and quantified using the exponentially modified protein abundance index. Later on, collagen solution was casted at room temperature obtaining an optically transparent and mechanically manageable membrane that supports the growth of human and rabbit corneal endothelial cells which expressed characteristic markers of corneal endothelium: zonula ocluddens-1 and Na+/K+ ATPase. To evaluate the therapeutic efficiency of our artificial endothelial grafts, human purified type I collagen membranes cultured with rabbit corneal endothelial cells were transplanted in New Zealand white rabbits that were kept under a minimal immunosuppression regimen. Transplanted corneas maintained transparency for as long as 6 weeks without obvious edema or immune rejection and maintaining the same endothelial markers that in a healthy cornea. In conclusion, it is possible to develop an artificial human corneal endothelial graft using remnant tissues that are not employed in transplant procedures. This artificial endothelial graft can restore the integrality of corneal endothelium in an experimental model of

  4. Correlation-based model of artificially induced plasticity in motor cortex by a bidirectional brain-computer interface.

    Science.gov (United States)

    Lajoie, Guillaume; Krouchev, Nedialko I; Kalaska, John F; Fairhall, Adrienne L; Fetz, Eberhard E

    2017-02-01

    Experiments show that spike-triggered stimulation performed with Bidirectional Brain-Computer-Interfaces (BBCI) can artificially strengthen connections between separate neural sites in motor cortex (MC). When spikes from a neuron recorded at one MC site trigger stimuli at a second target site after a fixed delay, the connections between sites eventually strengthen. It was also found that effective spike-stimulus delays are consistent with experimentally derived spike-timing-dependent plasticity (STDP) rules, suggesting that STDP is key to drive these changes. However, the impact of STDP at the level of circuits, and the mechanisms governing its modification with neural implants remain poorly understood. The present work describes a recurrent neural network model with probabilistic spiking mechanisms and plastic synapses capable of capturing both neural and synaptic activity statistics relevant to BBCI conditioning protocols. Our model successfully reproduces key experimental results, both established and new, and offers mechanistic insights into spike-triggered conditioning. Using analytical calculations and numerical simulations, we derive optimal operational regimes for BBCIs, and formulate predictions concerning the efficacy of spike-triggered conditioning in different regimes of cortical activity.

  5. Advanced Squamous Cell Carcinoma of Cornea in a Child with ...

    African Journals Online (AJOL)

    lids, conjunctiva, and cornea are affected by the disease process.[3] A case of XP ... In the left eye, almost the entire cornea was involved with a grayish-white, irregular, and ... referring to its characteristic dry pigmented skin. It was also named ...

  6. Correlation between epithelial thickness in normal corneas, untreated ectatic corneas, and ectatic corneas previously treated with CXL; is overall epithelial thickness a very early ectasia prognostic factor?

    Directory of Open Access Journals (Sweden)

    Kanellopoulos AJ

    2012-05-01

    Full Text Available Anastasios John Kanellopoulos,1,2 Ioannis M Aslanides,3 George Asimellis11Laservision Eye Institute, Athens, 2Emmetropia Mediterranean Eye Clinic, Crete, Greece, 3New York University School of Medicine, NY, USAPurpose: To determine and correlate epithelial corneal thickness (pachymetric measurements taken with a digital arc scanning very high frequency ultrasound biomicroscopy (HF UBM imaging system (Artemis-II, and compare mean and central epithelial thickness among normal eyes, untreated keratoconic eyes, and keratoconic eyes previously treated with collagen crosslinking (CXL.Methods: Epithelial pachymetry measurements (topographic mapping were conducted on 100 subjects via HF UBM. Three groups of patients were included: patients with normal eyes (controls, patients with untreated keratoconic eyes, and patients with keratoconic eyes treated with CXL. Central, mean, and peripheral corneal epithelial thickness was examined for each group, and a statistical study was conducted.Results: Mean, central, and peripheral corneal epithelial thickness was compared between the three groups of patients. Epithelium thickness varied substantially in the keratoconic group, and in some cases there was a difference of up to 20 µm between various points of the same eye, and often a thinner epithelium coincided with a thinner cornea. However, on average, data from the keratoconic group suggested an overall thickening of the epithelium, particularly over the pupil center of the order of +3 µm, while the mean epithelium thickness was on average +1.1 µm, compared to the control population (P = 0.005. This overall thickening was more pronounced in younger patients in the keratoconic group. Keratoconic eyes previously treated with CXL showed, on average, virtually the same average epithelium thickness (mean –0.7 µm, –0.2 µm over the pupil center, –0.9 µm over the peripheral zone as the control group. This finding further reinforces our novel theory of the

  7. Analysis of Riboflavin Compounds in the Rabbit Cornea In Vivo.

    Science.gov (United States)

    Hammer, Arthur; Rudaz, Serge; Guinchard, Sylvie; Kling, Sabine; Richoz, Olivier; Hafezi, Farhad

    2016-09-01

    To investigate the composition and concentration of individual riboflavin compounds in the corneal stroma in vivo after soaking with various commercially available riboflavin formulations. Experiments were performed in 26 rabbit corneas in vivo: 24 corneas were soaked with riboflavin formulations for 30 minutes or with 0.9% NaCl for control (n = 2). After treatment, corneas were excised and prepared for ultra-high-pressure liquid chromatography (UHPLC) analysis. Additionally, computational chemical analysis of riboflavin compounds and keratan sulfate were performed. The amount of riboflavin and riboflavin phosphate isomers in cornea decreased by a factor of 10 to 100, when compared to the amount in riboflavin formulations. In particular, we found an inverse relationship in the ratio of riboflavin to riboflavin phosphate isomer concentration between formulations and cornea. The electronegativity and ionization potential of riboflavin and phosphate isomers are different. The inverse relationship observed might be explained by a stronger electronegativity of the phosphate isomers, leading to a stronger repulsion by corneal proteoglycans. Indicating the individual concentration of riboflavin compounds in formulations is more representative than the total riboflavin concentration. Riboflavin formulations and CXL protocols might be improved considering the differences in diffusion and ionization potentials of the different riboflavin compounds.

  8. Clinical and epidemiological aspects of cornea transplant patients of a reference hospital 1

    Science.gov (United States)

    Cruz, Giovanna Karinny Pereira; de Azevedo, Isabelle Campos; Carvalho, Diana Paula de Souza Rego Pinto; Vitor, Allyne Fortes; Santos, Viviane Euzébia Pereira; Ferreira, Marcos Antonio

    2017-01-01

    ABSTRACT Objective: clinically characterizing cornea transplant patients and their distribution according to indicated and post-operative conditions of cornea transplantation, as well as estimating the average waiting time. Method: a cross-sectional, descriptive and analytical study performed for all cornea transplants performed at a reference service (n=258). Data were analyzed using Statistical Package for the Social Sciences, version 20.0. Results: the main indicator for cornea transplant was keratoconus. The mean waiting time for the transplant was approximately 5 months and 3 weeks for elective transplants and 9 days for urgent cases. An association between the type of corneal disorder with gender, age, previous surgery, eye classification, glaucoma and anterior graft failure were found. Conclusion: keratoconus was the main indicator for cornea transplant. Factors such as age, previous corneal graft failure (retransplantation), glaucoma, cases of surgeries prior to cornea transplant (especially cataract surgery) may be related to the onset corneal endothelium disorders. PMID:28614429

  9. Wound-Healing Studies in Cornea and Skin: Parallels, Differences and Opportunities.

    Science.gov (United States)

    Bukowiecki, Anne; Hos, Deniz; Cursiefen, Claus; Eming, Sabine A

    2017-06-12

    The cornea and the skin are both organs that provide the outer barrier of the body. Both tissues have developed intrinsic mechanisms that protect the organism from a wide range of external threats, but at the same time also enable rapid restoration of tissue integrity and organ-specific function. The easy accessibility makes the skin an attractive model system to study tissue damage and repair. Findings from skin research have contributed to unravelling novel fundamental principles in regenerative biology and the repair of other epithelial-mesenchymal tissues, such as the cornea. Following barrier disruption, the influx of inflammatory cells, myofibroblast differentiation, extracellular matrix synthesis and scar formation present parallel repair mechanisms in cornea and skin wound healing. Yet, capillary sprouting, while pivotal in proper skin wound healing, is a process that is rather associated with pathological repair of the cornea. Understanding the parallels and differences of the cellular and molecular networks that coordinate the wound healing response in skin and cornea are likely of mutual importance for both organs with regard to the development of regenerative therapies and understanding of the disease pathologies that affect epithelial-mesenchymal interactions. Here, we review the principal events in corneal wound healing and the mechanisms to restore corneal transparency and barrier function. We also refer to skin repair mechanisms and their potential implications for regenerative processes in the cornea.

  10. Accelerating repaired basement membrane after bevacizumab treatment on alkali-burned mouse cornea

    Science.gov (United States)

    Lee, Koon-Ja; Lee, Ji-Young; Lee, Sung Ho; Choi, Tae Hoon

    2013-01-01

    To understand the corneal regeneration induced by bevacizumab, we investigated the structure changes of stroma and basement membrane regeneration. A Stick soaked in 0.5 N NaOH onto the mouse cornea and 2.5 mg/ml of bevacizumab was delivered into an alkali-burned cornea (2 μl) by subconjunctival injections at 1 hour and 4 days after injury. At 7 days after injury, basement membrane regeneration was observed by transmission electron microscope. Uneven and thin epithelial basement membrane, light density of hemidesmosomes, and edematous collagen fibril bundles are shown in the alkali-burned cornea. Injured epithelial basement membrane and hemidesmosomes and edematous collagen fibril bundles resulting from alkali-burned mouse cornea was repaired by bevacizumab treatment. This study demonstrates that bevacizumab can play an important role in wound healing in the cornea by accelerating the reestablishment of basement membrane integrity that leads to barriers for scar formation. [BMB Reports 2013; 46(4): 195-200] PMID:23615260

  11. Dendritic cells in the cornea during Herpes simplex viral infection and inflammation.

    Science.gov (United States)

    Kwon, Min S; Carnt, Nicole A; Truong, Naomi R; Pattamatta, Ushasree; White, Andrew J; Samarawickrama, Chameen; Cunningham, Anthony L

    2017-11-10

    Herpes simplex keratitis is commonly caused by Herpes simplex virus type 1, which primarily infects eyelids, corneas, or conjunctiva. Herpes simplex virus type 1-through sophisticated interactions with dendritic cells (DCs), a type of antigen-presenting cell)-initiates proinflammatory responses in the cornea. Corneas were once thought to be an immune-privileged region; however, with the recent discovery of DCs that reside in the cornea, this long-held conjecture has been overturned. Therefore, evaluating the clinical, preclinical, and cell-based studies that investigate the roles of DCs in corneas infected with Herpes simplex virus is critical. With in vivo confocal microscopy, animal models, and cell culture experiments, we may further the understanding of the sophisticated interactions of Herpes simplex virus with DCs in the cornea and the molecular mechanism associated with it. It has been shown that specific differentiation of DCs using immunohistochemistry, flow cytometry, and polymerase chain reaction analysis in both human and mice tissues and viral tissue infections are integral to increasing understanding. As for in vivo confocal microscopy, it holds promise as it is the least invasive and a real-time investigation. These tools will facilitate the discovery of various targets to develop new treatments. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Comparison of confocal microscopy and two-photon microscopy in mouse cornea in vivo.

    Science.gov (United States)

    Lee, Jun Ho; Lee, Seunghun; Gho, Yong Song; Song, In Seok; Tchah, Hungwon; Kim, Myoung Joon; Kim, Ki Hean

    2015-03-01

    High-resolution imaging of the cornea is important for studying corneal diseases at cellular levels. Confocal microscopy (CM) has been widely used in the clinic, and two-photon microscopy (TPM) has recently been introduced in various pre-clinical studies. We compared the performance of CM and TPM in normal mouse corneas and neovascularized mouse corneas induced by suturing. Balb/C mice and C57BL/6 mice expressing green fluorescent protein (GFP) were used to compare modalities based on intrinsic contrast and extrinsic fluorescence contrast. CM based on reflection (CMR), CM based on fluorescence (CMF), and TPM based on intrinsic/extrinsic fluorescence and second harmonic generation (SHG) were compared by imaging the same sections of mouse corneas sequentially in vivo. In normal mouse corneas, CMR visualized corneal cell morphologies with some background noise, and CMF visualized GFP expressing corneal cells clearly. TPM visualized corneal cells and collagen in the stroma based on fluorescence and SHG, respectively. However, in neovascularized mouse corneas, CMR could not resolve cells deep inside the cornea due to high background noise from the effects of increased structural irregularity induced by suturing. CMF and TPM visualized cells and induced vasculature better than CMR because both collect signals from fluorescent cells only. Both CMF and TPM had signal decays with depth due to the structural irregularity, with CMF having faster signal decay than TPM. CMR, CMF, and TPM showed different degrees of image degradation in neovascularized mouse corneas. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Correlation-based model of artificially induced plasticity in motor cortex by a bidirectional brain-computer interface.

    Directory of Open Access Journals (Sweden)

    Guillaume Lajoie

    2017-02-01

    Full Text Available Experiments show that spike-triggered stimulation performed with Bidirectional Brain-Computer-Interfaces (BBCI can artificially strengthen connections between separate neural sites in motor cortex (MC. When spikes from a neuron recorded at one MC site trigger stimuli at a second target site after a fixed delay, the connections between sites eventually strengthen. It was also found that effective spike-stimulus delays are consistent with experimentally derived spike-timing-dependent plasticity (STDP rules, suggesting that STDP is key to drive these changes. However, the impact of STDP at the level of circuits, and the mechanisms governing its modification with neural implants remain poorly understood. The present work describes a recurrent neural network model with probabilistic spiking mechanisms and plastic synapses capable of capturing both neural and synaptic activity statistics relevant to BBCI conditioning protocols. Our model successfully reproduces key experimental results, both established and new, and offers mechanistic insights into spike-triggered conditioning. Using analytical calculations and numerical simulations, we derive optimal operational regimes for BBCIs, and formulate predictions concerning the efficacy of spike-triggered conditioning in different regimes of cortical activity.

  14. Use of Fourier-Domain Optical Coherence Tomography to Evaluate Anterior Stromal Opacities in Donor Corneas

    Directory of Open Access Journals (Sweden)

    Matthew R. Bald

    2013-01-01

    Full Text Available Purpose. To evaluate Fourier-domain optical coherence tomography (FD-OCT as an adjunct to traditional slit lamp examination of donor corneas with suspected Anterior Stromal Opacities. Methods. Seven corneas suspected of having anterior stromal opacities by slit lamp examination were evaluated with FD-OCT. Each cornea was evaluated to confirm the presence of opacity and, if present, the depth of opacity was measured. Results. The opacity depth ranged from 82 μm to 624 μm. The initial slit lamp impressions of five of the seven corneas were confirmed by OCT. In two corneas, the OCT findings were different from the initial slit lamp impressions. Slit lamp examination of the first cornea gave the impression of anterior stromal scarring, but OCT showed that the opacity was limited to the epithelium. Slit lamp examination of the second cornea suggested opacity limited to the epithelium, but OCT identified significant sub-Bowman's scarring. In all cases, the Eye Bank Technicians reported that the location and depth of corneal opacity were more sharply defined by OCT than by slit lamp. Conclusion. The high resolution of OCT makes it easier to determine the location of corneal opacities compared to slit lamp examinations. This enhanced visualization can improve decisions regarding transplant suitability of donor corneas.

  15. Thick keratoconic cornea associated with posterior polymorphous corneal dystrophy.

    Science.gov (United States)

    Zaarour, K; Slim, E; Antoun, J; Waked, N

    2017-03-01

    We herein report a case of bilateral unusually thick non-edematous keratoconic corneas with associated endothelial features of posterior polymorphous corneal dystrophy (PPCD). We report the case of a 27-year-old myopic woman who presented for refractive surgery. Slit lamp exam showed bilateral corneal protrusion with diffuse deep stromal and endothelial vesicular opacities and small paracentral bands. Topography showed generalized advanced corneal steepening in both eyes with increased anterior and posterior central corneal elevations in comparison to the best fit sphere. Ultrasound pachymetry showed central corneal thickness of 605μm (RE) and 612μm (LE). On specular biomicroscopy, cell density of 2503 cells/mm 2 RE and 1526 cells/mm 2 LE with significant cellular pleomorphism and polymegathism were noted. Clinical and paraclinical findings together suggest the presence of simultaneous keratoconus and PPCD. The literature has suggested an association between PPCD and steep cornea. Moreover, many reports have also described cases of associated PPCD and keratoconus with characteristic thinning and ectasia, in comparison to the unusual thick corneas noted in our patient, despite the absence of edema. Identification of genetics factors is further needed to clarify this association. This case describes a patient whose corneas present features of both keratoconus and PPCD and is unique due to the presence of increased corneal thickness despite the absence of edema. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  16. Correlation between epithelial thickness in normal corneas, untreated ectatic corneas, and ectatic corneas previously treated with CXL; is overall epithelial thickness a very early ectasia prognostic factor?

    Science.gov (United States)

    Kanellopoulos, Anastasios John; Aslanides, Ioannis M; Asimellis, George

    2012-01-01

    To determine and correlate epithelial corneal thickness (pachymetric) measurements taken with a digital arc scanning very high frequency ultrasound biomicroscopy (HF UBM) imaging system (Artemis-II), and compare mean and central epithelial thickness among normal eyes, untreated keratoconic eyes, and keratoconic eyes previously treated with collagen crosslinking (CXL). Epithelial pachymetry measurements (topographic mapping) were conducted on 100 subjects via HF UBM. Three groups of patients were included: patients with normal eyes (controls), patients with untreated keratoconic eyes, and patients with keratoconic eyes treated with CXL. Central, mean, and peripheral corneal epithelial thickness was examined for each group, and a statistical study was conducted. Mean, central, and peripheral corneal epithelial thickness was compared between the three groups of patients. Epithelium thickness varied substantially in the keratoconic group, and in some cases there was a difference of up to 20 μm between various points of the same eye, and often a thinner epithelium coincided with a thinner cornea. However, on average, data from the keratoconic group suggested an overall thickening of the epithelium, particularly over the pupil center of the order of +3 μm, while the mean epithelium thickness was on average +1.1 μm, compared to the control population (P = 0.005). This overall thickening was more pronounced in younger patients in the keratoconic group. Keratoconic eyes previously treated with CXL showed, on average, virtually the same average epithelium thickness (mean -0.7 μm, -0.2 μm over the pupil center, -0.9 μm over the peripheral zone) as the control group. This finding further reinforces our novel theory of the "reactive" component of epithelial thickening in corneas that are biomechanically unstable, becoming stable when biomechanical rigidity is accomplished despite persistence of cornea topographic irregularity. A highly irregular epithelium may be

  17. Comparison of the characteristics in hen and quail corneas as experimental models of refractive surgery.

    Science.gov (United States)

    Gonçalves, G C; Pérez-Merino, P; Martínez-García, M C; Barcía, A; Merayo-Loves, J

    2016-07-01

    To compare the histological, morphological and the biophysical measurements between hen and quail corneas, in order to determine which of them were better suited for use as an animal model for research into corneal refractive surgery. A study was performed using the biophysical measurements of the cornea (curvature, thickness, refraction, and axial length) of 20 animals (10 hens and 10 quails). The corneas were then prepared for histological analysis under microscopy light. The analysis showed that both groups have the same number of corneal layers as the human cornea and with an evident Bowman's layer. The thickness of the hen cornea and axial length of the eye, 225.3±18.4μm and 12.8±0.25mm, respectively, were larger than that of the quail (Phen central cornea, 3.65±0.08mm, was greater than that for the quail (Ppower of each cornea was similar. The proportion of total corneal thickness of the hen stroma, 82.6%, was more similar to that of the human than was the quail stroma, 72.5%. Within the hen stroma, the density of keratocytes, 8.57±1.49 per 5,000μm(2), was about half that in the quail stroma (Phen cornea, the stromal thickness and proportional similarity of the corneal layers with human cornea, the hen maybe better than the quail as an alternative species suitable for use in studies of corneal refractive surgery. Copyright © 2016 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  18. Factors influencing the contamination rate of human organ-cultured corneas.

    Science.gov (United States)

    Röck, Daniel; Wude, Johanna; Bartz-Schmidt, Karl U; Yoeruek, Efdal; Thaler, Sebastian; Röck, Tobias

    2017-12-01

    To assess the influence of donor, environment and storage factors on the contamination rate of organ-cultured corneas, to consider the microbiological species causing corneal contamination and to investigate the corresponding sensitivities. Data from 1340 consecutive donor corneas were analysed retrospectively. Logistic regression analysis was used to assess the influence of different factors on the contamination rate of organ-cultured corneas for transplantation. The mean annual contamination rate was 1.8 ± 0.4% (range: 1.3-2.1%); 50% contaminations were of fungal origin with exclusively Candida species, and 50% contaminations were of bacterial origin with Staphylococcus species being predominant. The cause of donor death including infection and multiple organ dysfunction syndrome increased the risk of bacterial or fungal contamination during organ culture (p = 0.007 and p = 0.014, respectively). Differentiating between septic and aseptic donors showed an increased risk of contamination for septic donors (p = 0.0020). Mean monthly temperature including warmer months increased the risk of contamination significantly (p = 0.0031). Sex, donor age, death to enucleation, death to corneoscleral disc excision and storage time did not increase the risk of contamination significantly. The genesis of microbial contamination in organ-cultured donor corneas seems to be multifactorial. The main source of fungal or bacterial contamination could be resident species from the skin flora. The rate of microbial contamination in organ-cultured donor corneas seems to be dependent on the cause of donor death and mean monthly temperature. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  19. In vitro confocal imaging of the rabbit cornea.

    Science.gov (United States)

    Masters, B R; Paddock, S

    1990-05-01

    We were able to observe in vitro the fine structure of the rabbit cornea using a laser scanning confocal microscope, especially in the regions between Descemet's membrane and the epithelial basal lamina. We observed submicrometre filaments throughout the stroma with high concentrations adjacent to Descemet's membrane, and found extensive interconnecting processes between stromal keratocytes. There are numerous regions containing nerve plexuses in the stroma. We found a deeply convoluted basal lamina adjacent to the epithelium, and observed regions containing junctions between endothelial cells in fluorescent images of rabbit corneas stained with the actin-specific compound fluorescein phalloidin.

  20. Lens regeneration from the cornea requires suppression of Wnt/β-catenin signaling.

    Science.gov (United States)

    Hamilton, Paul W; Sun, Yu; Henry, Jonathan J

    2016-04-01

    The frog, Xenopus laevis, possesses a high capacity to regenerate various larval tissues, including the lens, which is capable of complete regeneration from the cornea epithelium. However, the molecular signaling mechanisms of cornea-lens regeneration are not fully understood. Previous work has implicated the involvement of the Wnt signaling pathway, but molecular studies have been very limited. Iris-derived lens regeneration in the newt (Wolffian lens regeneration) has shown a necessity for active Wnt signaling in order to regenerate a new lens. Here we provide evidence that the Wnt signaling pathway plays a different role in the context of cornea-lens regeneration in Xenopus. We examined the expression of frizzled receptors and wnt ligands in the frog cornea epithelium. Numerous frizzled receptors (fzd1, fzd2, fzd3, fzd4, fzd6, fzd7, fzd8, and fzd10) and wnt ligands (wnt2b.a, wnt3a, wnt4, wnt5a, wnt5b, wnt6, wnt7b, wnt10a, wnt11, and wnt11b) are expressed in the cornea epithelium, demonstrating that this tissue is transcribing many of the ligands and receptors of the Wnt signaling pathway. When compared to flank epithelium, which is lens regeneration incompetent, only wnt11 and wnt11b are different (present only in the cornea epithelium), identifying them as potential regulators of cornea-lens regeneration. To detect changes in canonical Wnt/β-catenin signaling occurring within the cornea epithelium, axin2 expression was measured over the course of regeneration. axin2 is a well-established reporter of active Wnt/β-catenin signaling, and its expression shows a significant decrease at 24 h post-lentectomy. This decrease recovers to normal endogenous levels by 48 h. To test whether this signaling decrease was necessary for lens regeneration to occur, regenerating eyes were treated with either 6-bromoindirubin-3'-oxime (BIO) or 1-azakenpaullone - both activators of Wnt signaling - resulting in a significant reduction in the percentage of cases with successful

  1. Surveillance of Vittaforma corneae in hot springs by a small-volume procedure.

    Science.gov (United States)

    Chen, Jung-Sheng; Hsu, Tsui-Kang; Hsu, Bing-Mu; Huang, Tung-Yi; Huang, Yu-Li; Shaio, Men-Fang; Ji, Dar-Der

    2017-07-01

    Vittaforma corneae is an obligate intracellular fungus and can cause human ocular microsporidiosis. Although accumulating reports of V. corneae causing keratoconjunctivitis in both healthy and immunocompromised persons have been published, little is known about the organism's occurrence in aquatic environments. Limitations in detection sensitivity have meant a large sampling volume is required to detect the pathogen up to now, which is problematic. A recent study in Taiwan has shown that some individuals suffering from microsporidial keratitis (MK) were infected after exposure to the pathogen at a hot spring. As a consequence of this, a survey and analysis of environmental V. corneae present in hot springs became an urgent need. In this study, sixty water samples from six hot spring recreation areas around Taiwan were analyzed. One liter of water from each sample site was filtered to harvest the fungi. The positive samples were detected using a modified nested PCR approach followed by sequencing using specific SSU rRNA gene primer pairs for V. corneae. In total fifteen V. corneae-like isolates were identified (25.0% of sites). Among them, six isolates, which were collected from recreational areas B, C and D, were highly similar to known V. corneae keratitis strains from Taiwan and other countries. Furthermore, five isolates, which were collected from recreation areas A, C, E and F, were very similar to Vittaforma-like diarrhea strains isolated in Portugal. Cold spring water tubs and public foot bath pools had the highest detection rate (50%), suggesting that hot springs might be contaminated via untreated water sources. Comparing the detection rate across different regions of Taiwan, Taitung, which is in the east of the island, gave the highest positive rate (37.5%). Statistical analysis showed that outdoor/soil exposure and a high heterotrophic plate count (HPC) were risk factors for the occurrence of V. corneae. Our findings provide empirical evidence

  2. [Cornea bank of Lyon: from quality diagnosis to ISO 9001 certification].

    Science.gov (United States)

    Pascal, P; Chalochet, A; Damour, O

    2001-12-01

    The tissue and cell bank of the HCL (Hospices Civils de Lyon) has, since 10 June 1999, consisted of two sections with related activities: cell culture for the Skin Substitutes Laboratory (Laboratoire des Substituts Cutanés, LSC) and preservation of corneas at 31 degrees C for the Cornea Bank. As the LSC had been ISO 9001 certified since March 1997 our aim, since merger, was to raise the Cornea Bank to the same level of quality as the LSC, so as to coincide with the renewal of the LSC certificate in February 2000. The methods we used (project, quality control, analysis and process optimization) led us to receive official certification only nine months after the merger. The procedure started with a program of quality control at the Cornea Bank from February 1999 onwards, in order to list the work and equipment required, evaluate its documentation system and what was needed to incorporate this new activity into the existing system of quality assurance at the LSC. On the 7th March 2000, the Tissue and Cell Bank of the HCL obtained an ISO 9001 certificate for its combined functions. As well as achieving our objectives and the strong points highlighted by the auditor during the renewal process, this quality assessment revealed many advantages: improvements in the conservation of corneas, economies in staff replacement and reductions in both the cost of maintaining quality, the cost of the corneas themselves, etc. The decree 'Banque' no. 99-741 of 30th August 1999, which put in place the system of authorization of tissue banks in France, demands quality control. Our application for certification which started in early 1999 had anticipated this regulation. This helped us enormously when compiling the dossier accompanying the official request and was an essential element in obtaining the favourable response of the ASSAPS on 21 June 2000.

  3. Accelerating repaired basement membrane after bevacizumab treatment on alkali-burned mouse cornea

    Directory of Open Access Journals (Sweden)

    Koon-Ja Lee

    2013-04-01

    Full Text Available To understand the corneal regeneration induced by bevacizumab,we investigated the structure changes of stroma andbasement membrane regeneration. A Stick soaked in 0.5 NNaOH onto the mouse cornea and 2.5 mg/ml of bevacizumabwas delivered into an alkali-burned cornea (2 μl by subconjunctivalinjections at 1 hour and 4 days after injury. At 7 daysafter injury, basement membrane regeneration was observedby transmission electron microscope. Uneven and thin epithelialbasement membrane, light density of hemidesmosomes,and edematous collagen fibril bundles are shown in thealkali-burned cornea. Injured epithelial basement membraneand hemidesmosomes and edematous collagen fibril bundlesresulting from alkali-burned mouse cornea was repaired bybevacizumab treatment. This study demonstrates that bevacizumabcan play an important role in wound healing in thecornea by accelerating the reestablishment of basementmembrane integrity that leads to barriers for scar formation.[BMB Reports 2013; 46(4: 195-200

  4. Cornea nerve fiber quantification and construction of phenotypes in patients with fibromyalgia.

    Science.gov (United States)

    Oudejans, Linda; He, Xuan; Niesters, Marieke; Dahan, Albert; Brines, Michael; van Velzen, Monique

    2016-03-23

    Cornea confocal microscopy (CCM) is a novel non-invasive method to detect small nerve fiber pathology. CCM generally correlates with outcomes of skin biopsies in patients with small fiber pathology. The aim of this study was to quantify the morphology of small nerve fibers of the cornea of patients with fibromyalgia in terms of density, length and branching and further phenotype these patients using standardized quantitative sensory testing (QST). Small fiber pathology was detected in the cornea of 51% of patients: nerve fiber length was significantly decreased in 44% of patients compared to age- and sex-matched reference values; nerve fiber density and branching were significantly decreased in 10% and 28% of patients. The combination of the CCM parameters and sensory tests for central sensitization, (cold pain threshold, mechanical pain threshold, mechanical pain sensitivity, allodynia and/or windup), yielded four phenotypes of fibromyalgia patients in a subgroup analysis: one group with normal cornea morphology without and with signs of central sensitization, and a group with abnormal cornea morphology parameters without and with signs of central sensitization. In conclusion, half of the tested fibromyalgia population demonstrates signs of small fiber pathology as measured by CCM. The four distinct phenotypes suggest possible differences in disease mechanisms and may require different treatment approaches.

  5. Sorption of sodium hydroxide by type I collagen and bovine corneas.

    Science.gov (United States)

    Whikehart, D R; Edwards, W C; Pfister, R R

    1991-01-01

    There are no quantitative studies on the uptake of alkali into corneal tissues. To study this phenomenon, both type I collagen and bovine corneas were incubated in sodium hydroxide (NaOH) under varying conditions for periods up to 27.5 h. The sorption (absorption or adsorption) of the alkali to protein and tissue was measured as the quantity of NaOH no longer available for titration to neutrality with hydrochloric acid. Sorption was found to be dependent on the concentration of NaOH (0.01-1 N) but independent of the incubation temperature (4-35 degrees C). In whole cornea, sorption of 1 N NaOH began immediately and increased with time up to 6 h. After 6 h, sorption decreased, together with the observed degradation and solubilization of the tissue. Stripping of the corneal endothelium alone or of the endothelium and epithelium increased sorption in a similar manner when compared to whole corneas for periods up to 4 h. These observations are compatible with ionic and nonionic bonding of hydroxide ions to collagen (including that of the cornea) and the subsequent release of hydroxide ions during hydrolysis of the protein itself. Indirect evidence also suggests the inclusion of quantities of unbound hydroxide ions in hydrated gels of glycosaminoglycans. It is proposed that in a chemical burn of the cornea, alkali is both stored in the tissue (by sorption) and reacted with it (by hydrolysis), without any net consumption of alkali taking place.

  6. Intrastromal Injection of China Painting Ink in Corneas of Male Rabbits: Clinical and Histological Study.

    Science.gov (United States)

    Alsmman Hassan, Alahmady Hamad; Abd Elhaliem Soliman, Nesreen Gamal-Eldeen

    2016-01-01

    Background. Many patients with corneal opacity or complicated cataract in blind eye ask for cosmoses. In this study we tried to investigate the staining of corneas of male rabbits by Rotring China painting ink and to study the histological changes. Method. 10 eyes of 10 male Baladi Egyptian rabbits were injected (0.1 mL) intrastromally in the cornea by the use of China painting ink (Rotring Tinta China) through insulin syringe (27-gauge needle) by single injection; clinical follow-up is for 6 months and lastly the rabbits were scarified and the stained eyes were enucleated for histological analysis. Results. Clinically the stain was stable in color and distribution in corneas with no major complications. Histological results of the stained rabbit corneas showed blackish pigmentation in the corneal stroma without any inflammatory cellular infiltration. Some fibroblast cells had pigment granules in their cytoplasm in the adjacent layers. Conclusion. Corneal staining by China painting ink is effective and safe in staining of male rabbits cornea; however further study in human corneas with longer follow-up period is advisable.

  7. Intrastromal Injection of China Painting Ink in Corneas of Male Rabbits: Clinical and Histological Study

    Directory of Open Access Journals (Sweden)

    Alahmady Hamad Alsmman Hassan

    2016-01-01

    Full Text Available Background. Many patients with corneal opacity or complicated cataract in blind eye ask for cosmoses. In this study we tried to investigate the staining of corneas of male rabbits by Rotring China painting ink and to study the histological changes. Method. 10 eyes of 10 male Baladi Egyptian rabbits were injected (0.1 mL intrastromally in the cornea by the use of China painting ink (Rotring Tinta China through insulin syringe (27-gauge needle by single injection; clinical follow-up is for 6 months and lastly the rabbits were scarified and the stained eyes were enucleated for histological analysis. Results. Clinically the stain was stable in color and distribution in corneas with no major complications. Histological results of the stained rabbit corneas showed blackish pigmentation in the corneal stroma without any inflammatory cellular infiltration. Some fibroblast cells had pigment granules in their cytoplasm in the adjacent layers. Conclusion. Corneal staining by China painting ink is effective and safe in staining of male rabbits cornea; however further study in human corneas with longer follow-up period is advisable.

  8. Hydration and transparency of the rabbit cornea irradiated with UVB-doses of 0.25 J/cm(2) and 0.5 J/cm(2) compared with equivalent UVB radiation exposure reaching the human cornea from sunlight.

    Science.gov (United States)

    Cejka, Cestmír; Ardan, Taras; Sirc, Jakub; Michálek, Jiří; Beneš, Jiří; Brůnová, Blanka; Rosina, Jozef

    2011-07-01

    Exposure of the cornea to UV radiation from sunlight evokes intraocular inflammation, photokeratitis. Photokeratitis is caused by UVB radiation. It is accompanied by changes of corneal hydration and light absorption. The aim of this study was to examine the effect of two UVB doses on corneal optics in rabbits and to compare these UVB doses with the equivalent exposure of UVB radiation reaching the human cornea from sunlight. Rabbit corneas were irradiated with a daily UVB dose of 0.25 J/cm(2) or 0.5 J/cm(2) for 4 days. One day after finishing the irradiations the rabbits were sacrificed and corneal light absorption measured using our spectrophotometrical method. Corneal hydration was examined using an ultrasonic Pachymeter every experimental day before the irradiation procedure and the last day before sacrificing the animals. Changes in corneal optics appeared after the repeated exposure of the cornea to a UVB dose of 0.25 J/ cm(2) and massively increased after the repeated exposure of the cornea to a UVB dose of 0.5 J/cm(2). The first significant changes in corneal hydration appeared after a single exposure of the cornea to a UVB dose of 0.25 J/cm(2). Changes in corneal hydration appeared after the exposure of the rabbit cornea to a single UVB dose equivalent to 2.6 hours of solar UVB radiation reaching the human cornea, as measured by UVB sensors embedded in the eyes of mannequin heads facing the sun on a beach at noon in July. Repeated exposure of the rabbit cornea to the same UVB dose evoked profound changes in corneal optics. Although comparison of experimental and outdoor conditions are only approximate, the results in rabbits point to the danger for the human eye from UVB radiation when short stays in sunlight are repeated for several consecutive days without UV protection.

  9. Lectin receptors in the human cornea.

    Science.gov (United States)

    Holmes, M J; Mannis, M J; Lund, J; Jacobs, L

    Five different biotin labeled lectins, Concanavalin-A (Con A), wheat germ agglutinin (WGA), Ricinus communis agglutinin I (RCA1), Ulex europaeus agglutinin (UEA1), and soybean agglutinin (SBA) were used to study lectin receptors on formalin-fixed paraffin embedded human corneas. Con A stained the cytoplasm, cell, and nuclear membranes of the epithelial cells and stained the stroma diffusely. WGA stained the superficial epithelial cells, the epithelial cell membranes, and the keratocytes of the stroma. SBA did not react with any of the corneal layers. RCA1 heavily stained the keratocytes but did not stain the epithelium. UEA1 lightly stained the epithelial cell cytoplasm and interstitial stroma. All staining reactions could be abolished by omission of the lectin or by the use of the appropriate inhibitory sugar. The lectin binding patterns reported here provide a means for further investigation of carbohydrate structures in the human cornea in both normal and disease states.

  10. Elastic microfibril distribution in the cornea: Differences between normal and keratoconic stroma.

    Science.gov (United States)

    White, Tomas L; Lewis, Philip N; Young, Robert D; Kitazawa, Koji; Inatomi, Tsutomu; Kinoshita, Shigeru; Meek, Keith M

    2017-06-01

    The optical and biomechanical properties of the cornea are largely governed by the collagen-rich stroma, a layer that represents approximately 90% of the total thickness. Within the stroma, the specific arrangement of superimposed lamellae provides the tissue with tensile strength, whilst the spatial arrangement of individual collagen fibrils within the lamellae confers transparency. In keratoconus, this precise stromal arrangement is lost, resulting in ectasia and visual impairment. In the normal cornea, we previously characterised the three-dimensional arrangement of an elastic fiber network spanning the posterior stroma from limbus-to-limbus. In the peripheral cornea/limbus there are elastin-containing sheets or broad fibers, most of which become microfibril bundles (MBs) with little or no elastin component when reaching the central cornea. The purpose of the current study was to compare this network with the elastic fiber distribution in post-surgical keratoconic corneal buttons, using serial block face scanning electron microscopy and transmission electron microscopy. We have demonstrated that the MB distribution is very different in keratoconus. MBs are absent from a region of stroma anterior to Descemet's membrane, an area that is densely populated in normal cornea, whilst being concentrated below the epithelium, an area in which they are absent in normal cornea. We contend that these latter microfibrils are produced as a biomechanical response to provide additional strength to the anterior stroma in order to prevent tissue rupture at the apex of the cone. A lack of MBs anterior to Descemet's membrane in keratoconus would alter the biomechanical properties of the tissue, potentially contributing to the pathogenesis of the disease. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Cytogenetic damage and postradiation restoration of eye cornea epithelium of Rodentia characterizing by different radiosensitivity

    International Nuclear Information System (INIS)

    Popova, M.F.; Bulyakova, N.V.

    1983-01-01

    Intensity of beam damage and reparation of eye cornea epithelium of animals inhabiting under different conditions and differing by radiosensitivity has been studied. Mice differing by high radiosensitivity have the hardest cytogenetic damage. Cornea epithelium of bank voles is more radiostable than that of mice. The most negligible damages of cornea epithelium is observed in Mongolian sandwort despite the fact that their total radiation stability is lower than that of bank voles. High protective-restoring properties of eye cornea epithelium of Mongolian sandwort are explained by the structure of epithelium cells diffe-- ring by a large number of cytoplasm

  12. Development of a microfabricated artificial limbus with micropockets for cell delivery to the cornea

    International Nuclear Information System (INIS)

    Ortega, Ílida; Deshpande, Pallavi; Gill, Andrew A; MacNeil, Sheila; Claeyssens, Frederik

    2013-01-01

    The aim of this study was to develop a synthetic alternative to the human corneal limbus for use initially as an ex vivo model in which to study corneal stem cell function within a niche environment and ultimately to develop an implantable limbus for future clinical use. Microstereolithography was used for the fabrication of polyethylene glycol diacrylate (PEGDA) based rings on a macroscopic (1.2 cm) scale containing unique microfeatures (pockets) which were then modified with fibronectin to promote cell adhesion. These rings were designed to mimic the limbal area of the eye containing structures of the approximate size and shape of the stem cell microenvironments found in the palisades of Vogt. The attachment of rabbit limbal fibroblasts and rabbit limbal epithelial cells to the PEGDA rings was increased by pretreating the microfabricated structures with biotinylated fibronectin. Cell outgrowth from fibronectin coated microfabricated structures was 50% greater than from rings without structures or fibronectin coating. The cell loaded rings were then placed on an ex vivo wounded cornea model and the outgrowth of cells to form a multilayered epithelium was observed. We suggest this is a new approach to investigating limbal stem cells niches and the first steps towards a new approach for corneal regeneration. (paper)

  13. Plastics and environment

    International Nuclear Information System (INIS)

    Avenas, P.

    1996-01-01

    Synthetic organic polymers, such as plastics, PVC, polyamides etc are considered less ecological than natural materials such as wood. Other artificial materials such as metals, glass or biodegradable plastics have also a better image than petroleum products. This short paper demonstrates that the manufacturing or the transport of every material uses energy and that the complete energy balance sheet of a plastic bottle, for instance, is more favourable than the one of a glass bottle. Plastic materials are also easily valorized and recycled and part of the energy spent during manufacturing can be recovered during incineration for district heating. During the life-cycle of such a synthetic material, the same petroleum quantity can be used twice which leads to less negative effects on the environment. Finally, the paper focusses on the problem of biodegradable materials which are not degradable when buried under several meters of wastes and which are a nuisance to recycling. (J.S.)

  14. In vivo confocal Raman spectroscopy of the human cornea.

    Science.gov (United States)

    Bauer, N J; Hendrikse, F; March, W F

    1999-07-01

    To investigate the feasibility of a confocal Raman spectroscopic technique for the noninvasive assessment of corneal hydration in vivo in two legally blind subjects. A laser beam (632.8 nm; 15 mJ) was maintained on the cornea by using a microscope objective lens (x25 magnification, NA = 0.5, f = 10 mm) both for focusing the incident light as well as collecting the Raman backscattered light, in a 180 degrees backscatter configuration. An optical fiber, acting as the confocal pinhole for elimination of light from out-of-focus places, was coupled to a spectrometer that dispersed the collected light onto a sensitive array detector for rapid spectral data acquisition over a range from 2,890 to 3,590/cm(-1). Raman spectra were recorded from the anterior 100-150 microm of the cornea over a period before and after topical application of a mild dehydrating solution. The ratio between the amplitudes of the signals at 3,400/cm(-1) (OH-vibrational mode of water) and 2,940/cm(-1) (CH-vibrational mode of proteins) was used as a measure for corneal hydration. High signal-to-noise ratio (SNR = 25) Raman spectra were obtained from the human corneas by using 15 mJ of laser light energy. Qualitative changes in the hydration of the anteriormost part of the corneas could be observed as a result of the dehydrating agent. With adequate improvements in system safety, confocal Raman spectroscopy could potentially be applied clinically as a noninvasive tool for the assessment of corneal hydration in vivo.

  15. Experimental corneal calcification, hydration and /sup 45/Ca uptake in rabbit corneas incubated in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Obenberger, J [Ceskoslovenska Akademie Ved, Prague. Oftalmologicka Laborator; Dobiasova, M; Babicky, A [Ceskoslovenska Akademie Ved, Prague. Isotopova Laborator Biologickych Ustavu

    1974-07-01

    Experimental corneal calcification could easily be produced by a combination of corneal injury (perfusion of the anterior chamber of the eye with a solution of potassium permanganate) amd dihydrotachysterol (DHT) treatment. Rabbit corneas with induced calcification as well as corneas of three additional groups of rabbits, i.e. those treated with permanganate or DHT only and control animals were incubated for two hours in a medium containing /sup 45/Ca. An increased uptake of /sup 45/Ca into the cornea was found in the group of rabbits receiving DHT only. Potassium cyanide added to the incubation medium did not affect corneal hydration nor the final activity of the incubated corneas. (auth)

  16. Differentially expressed wound healing-related microRNAs in the human diabetic cornea.

    Science.gov (United States)

    Funari, Vincent A; Winkler, Michael; Brown, Jordan; Dimitrijevich, Slobodan D; Ljubimov, Alexander V; Saghizadeh, Mehrnoosh

    2013-01-01

    MicroRNAs are powerful gene expression regulators, but their corneal repertoire and potential changes in corneal diseases remain unknown. Our purpose was to identify miRNAs altered in the human diabetic cornea by microarray analysis, and to examine their effects on wound healing in cultured telomerase-immortalized human corneal epithelial cells (HCEC) in vitro. Total RNA was extracted from age-matched human autopsy normal (n=6) and diabetic (n=6) central corneas, Flash Tag end-labeled, and hybridized to Affymetrix® GeneChip® miRNA Arrays. Select miRNAs associated with diabetic cornea were validated by quantitative RT-PCR (Q-PCR) and by in situ hybridization (ISH) in independent samples. HCEC were transfected with human pre-miR™miRNA precursors (h-miR) or their inhibitors (antagomirs) using Lipofectamine 2000. Confluent transfected cultures were scratch-wounded with P200 pipette tip. Wound closure was monitored by digital photography. Expression of signaling proteins was detected by immunostaining and Western blot. Using microarrays, 29 miRNAs were identified as differentially expressed in diabetic samples. Two miRNA candidates showing the highest fold increased in expression in the diabetic cornea were confirmed by Q-PCR and further characterized. HCEC transfection with h-miR-146a or h-miR-424 significantly retarded wound closure, but their respective antagomirs significantly enhanced wound healing vs. controls. Cells treated with h-miR-146a or h-miR-424 had decreased p-p38 and p-EGFR staining, but these increased over control levels close to the wound edge upon antagomir treatment. In conclusion, several miRNAs with increased expression in human diabetic central corneas were found. Two such miRNAs inhibited cultured corneal epithelial cell wound healing. Dysregulation of miRNA expression in human diabetic cornea may be an important mediator of abnormal wound healing.

  17. Differentially expressed wound healing-related microRNAs in the human diabetic cornea.

    Directory of Open Access Journals (Sweden)

    Vincent A Funari

    Full Text Available MicroRNAs are powerful gene expression regulators, but their corneal repertoire and potential changes in corneal diseases remain unknown. Our purpose was to identify miRNAs altered in the human diabetic cornea by microarray analysis, and to examine their effects on wound healing in cultured telomerase-immortalized human corneal epithelial cells (HCEC in vitro. Total RNA was extracted from age-matched human autopsy normal (n=6 and diabetic (n=6 central corneas, Flash Tag end-labeled, and hybridized to Affymetrix® GeneChip® miRNA Arrays. Select miRNAs associated with diabetic cornea were validated by quantitative RT-PCR (Q-PCR and by in situ hybridization (ISH in independent samples. HCEC were transfected with human pre-miR™miRNA precursors (h-miR or their inhibitors (antagomirs using Lipofectamine 2000. Confluent transfected cultures were scratch-wounded with P200 pipette tip. Wound closure was monitored by digital photography. Expression of signaling proteins was detected by immunostaining and Western blot. Using microarrays, 29 miRNAs were identified as differentially expressed in diabetic samples. Two miRNA candidates showing the highest fold increased in expression in the diabetic cornea were confirmed by Q-PCR and further characterized. HCEC transfection with h-miR-146a or h-miR-424 significantly retarded wound closure, but their respective antagomirs significantly enhanced wound healing vs. controls. Cells treated with h-miR-146a or h-miR-424 had decreased p-p38 and p-EGFR staining, but these increased over control levels close to the wound edge upon antagomir treatment. In conclusion, several miRNAs with increased expression in human diabetic central corneas were found. Two such miRNAs inhibited cultured corneal epithelial cell wound healing. Dysregulation of miRNA expression in human diabetic cornea may be an important mediator of abnormal wound healing.

  18. Ex vivo rabbit cornea diffusion studies with a soluble insert of moxifloxacin.

    Science.gov (United States)

    Sebastián-Morelló, María; Calatayud-Pascual, María Aracely; Rodilla, Vicent; Balaguer-Fernández, Cristina; López-Castellano, Alicia

    2018-02-01

    The objective of this research was to develop and evaluate an ocular insert for the controlled drug delivery of moxifloxacin which could perhaps be used in the treatment of corneal keratitis or even bacterial endophthalmitis. We have evaluated the ex vivo ocular diffusion of moxifloxacin through rabbit cornea, both fresh and preserved under different conditions. Histological studies were also carried out. Subsequently, drug matrix inserts were prepared using bioadhesive polymers. The inserts were evaluated for their physicochemical parameters. Ophthalmic ex vivo permeation of moxifloxacin was carried out with the most promising insert. The formulate insert was thin and provided higher ocular diffusion than commercial formulations. Ocular diffusion studies revealed significant differences between fresh and frozen corneas. Histological examinations also showed differences in the thickness of stroma between fresh and frozen corneas. The ophthalmic insert we have developed allows a larger quantity of moxifloxacin to permeate through the cornea than existing commercial formulations of the drug. Ocular delivery of moxifloxacin with this insert could be a new approach for the treatment of eye diseases.

  19. Inflammation Modulatory Protein TSG-6 for Chemical Injuries to the Cornea

    Science.gov (United States)

    2017-10-01

    AWARD NUMBER: W81XWH-14-1-0495 TITLE: Inflammation Modulatory Protein TSG-6 for Chemical Injuries to the Cornea PRINCIPAL INVESTIGATOR...2017 4. TITLE AND SUBTITLE Inflammation Modulatory Protein TSG-6 for Chemical Injuries to the Cornea Infla I Inflammation Modulatory Protein TSG-6...anti-inflammatory protein , TSG-6, which has a novel mechanism of action. Chemical injuries of the eye are difficult to treat, and may lead to

  20. Inspection of an artificial heart by the neutron radiography technique

    International Nuclear Information System (INIS)

    Pugliesi, R.; Geraldo, L.P.; Andrade, M.L.G.; Menezes, M.O.; Pereira, M.A.S.; Maizato, M.J.S.

    1999-01-01

    The neutron radiography technique was employed to inspect an artificial heart prototype which is being developed to provide blood circulation for patients expecting heart transplant surgery. The radiographs have been obtained by the direct method with a gadolinium converter screen along with the double coated Kodak-AA emulsion film. The artificial heart consists of a flexible plastic membrane located inside a welded metallic cavity, which is employed for blood pumping purposes. The main objective of the present inspection was to identify possible damages in this plastic membrane, produced during the welding process of the metallic cavity. The obtained radiographs were digitized as well as analysed in a PC and the improved images clearly identify several damages in the plastic membrane, suggesting changes in the welding process

  1. Inspection of an artificial heart by the neutron radiography technique

    CERN Document Server

    Pugliesi, R; Andrade, M L G; Menezes, M O; Pereira, M A S; Maizato, M J S

    1999-01-01

    The neutron radiography technique was employed to inspect an artificial heart prototype which is being developed to provide blood circulation for patients expecting heart transplant surgery. The radiographs have been obtained by the direct method with a gadolinium converter screen along with the double coated Kodak-AA emulsion film. The artificial heart consists of a flexible plastic membrane located inside a welded metallic cavity, which is employed for blood pumping purposes. The main objective of the present inspection was to identify possible damages in this plastic membrane, produced during the welding process of the metallic cavity. The obtained radiographs were digitized as well as analysed in a PC and the improved images clearly identify several damages in the plastic membrane, suggesting changes in the welding process.

  2. High-resolution, label-free two-photon imaging of diseased human corneas

    Science.gov (United States)

    Batista, Ana; Breunig, Hans Georg; König, Aisada; Schindele, Andreas; Hager, Tobias; Seitz, Berthold; König, Karsten

    2018-03-01

    The diagnosis of corneal diseases may be improved by monitoring the metabolism of cells and the structural organization of the stroma using two-photon imaging (TPI). We used TPI to assess the differences between nonpathological (NP) human corneas and corneas diagnosed with either keratoconus, Acanthamoeba keratitis, or stromal corneal scars. Images were acquired using a custom-built five-dimensional laser-scanning microscope with a broadband sub-15 femtosecond near-infrared pulsed excitation laser and a 16-channel photomultiplier tube detector in combination with a time-correlated single photon counting module. Morphological alterations of epithelial cells were observed for all pathologies. Moreover, diseased corneas showed alterations to the cells' metabolism that were revealed using the NAD(P)H free to protein-bound ratios. The mean autofluorescence lifetime of the stroma and the organization of the collagen fibers were also significantly altered due to the pathologies. We demonstrate that TPI can be used to distinguish between NP and diseased human corneas, based not only on alterations of the cells' morphology, which can also be evaluated using current clinical devices, but on additional morphological and functional features such as the organization of the stroma and the cells' metabolism. Therefore, TPI could become an efficient tool for diagnosing corneal diseases and better understanding the biological processes of the diseases.

  3. Oxygen transport through soft contact lens and cornea: Lens characterization and metabolic modeling

    Science.gov (United States)

    Chhabra, Mahendra

    The human cornea requires oxygen to sustain metabolic processes critical for its normal functioning. Any restriction to corneal oxygen supply from the external environment (e.g., by wearing a low oxygen-permeability contact lens) can lead to hypoxia, which may cause corneal edema (swelling), limbal hyperemia, neovascularization, and corneal acidosis. The need for adequate oxygen to the cornea is a major driving force for research and development of hypertransmissible soft contact lenses (SCLs). Currently, there is no standard technique for measuring oxygen permeability (Dk) of hypertransmissible silicone-hydrogel SCLs. In this work, an electrochemistry-based polarographic apparatus was designed, built, and operated to measure oxygen permeability in hypertransmissible SCLs. Unlike conventional methods where a range of lens thickness is needed for determining oxygen permeabilities of SCLs, this apparatus requires only a single lens thickness. The single-lens permeameter provides a reliable, efficient, and economic tool for measuring oxygen permeabilities of commercial hypertransmissible SCLs. The single-lens permeameter measures not only the product Dk, but, following modification, it measures separately diffusivity, D, and solubility, k, of oxygen in hypertransmissible SCLs. These properties are critical for designing better lens materials that ensure sufficient oxygen supply to the cornea. Metabolism of oxygen in the cornea is influenced by contact-lens-induced hypoxia, diseases such as diabetes, surgery, and drug treatment, Thus, estimation of the in-vivo corneal oxygen consumption rate is essential for gauging adequate oxygen supply to the cornea. Therefore, we have developed an unsteady-state reactive-diffusion model for the cornea-contact-lens system to determine in-vivo human corneal oxygen-consumption rate. Finally, a metabolic model was developed to determine the relation between contact-lens oxygen transmissibility (Dk/L) and corneal oxygen deficiency. A

  4. Morphology of endothelial cells from different regions of the equine cornea

    OpenAIRE

    Faganello, Cláudia Skilhan; Silva, Vanessa Ruiz Moura da; Andrade, Maria Cristina Caldart de; Carissimi, André Silva; Pigatto, João Antonio Tadeu

    2016-01-01

    ABSTRACT: The objective of this study was to evaluate the morphology of different regions of the equine cornea using optical microscopy. Both healthy eyes of eight horses, male or female, of different ages were evaluated. Corneas were stained with alizarin red vital dye and subsequently examined and photographed using optical microscopy. Corneal endothelial morphology of central, superior, inferior, temporal and nasal areas was assessed. One hundred endothelial cells from each corneal area we...

  5. The use of human cornea organotypic cultures to study herpes simplex virus type 1 (HSV-1)-induced inflammation.

    Science.gov (United States)

    Drevets, Peter; Chucair-Elliott, Ana; Shrestha, Priyadarsini; Jinkins, Jeremy; Karamichos, Dimitrios; Carr, Daniel J J

    2015-10-01

    To determine the utility of human organotypic cornea cultures as a model to study herpes simplex virus type 1 (HSV-1)-induced inflammation and neovascularization. Human organotypic cornea cultures were established from corneas with an intact limbus that were retrieved from donated whole globes. One cornea culture was infected with HSV-1 (10(4) plaque-forming units), while the other cornea from the same donor was mock-infected. Supernatants were collected at intervals post-culture with and without infection to determine viral titer (by plaque assay) and pro-angiogenic and proinflammatory cytokine concentration by suspension array analysis. In some experiments, the cultured corneas were collected and evaluated for HSV-1 antigens by immunohistochemical means. Another set of experiments measured susceptibility of human three-dimensional cornea fibroblast constructs, in the presence and absence of TGF-β1, to HSV-1 infection in terms of viral replication and the inflammatory response to infection as a comparison to the organotypic cornea cultures. Organotypic cornea cultures and three-dimensional fibroblast constructs exhibited varying degrees of susceptibility to HSV-1. Fibroblast constructs were more susceptible to infection in terms of infectious virus recovered in a shorter period of time. There were changes in the levels of select pro-angiogenic or proinflammatory cytokines that were dictated as much by the cultures producing them as by whether they were infected with HSV-1 or treated with TGF-β1. Organotypic cornea and three-dimensional fibroblast cultures are likely useful for the identification and short-term study of novel antiviral compounds and virus replication, but are limited in the study of the local immune response to infection.

  6. Cornea procurement, preservation and transplantation

    International Nuclear Information System (INIS)

    Hudson Silva

    1999-01-01

    Our experience on this subject is 40 years and we have seen the developments everywhere during this total period. Cornea procurement has been an unsurmountable problem in a large number of countries, mostly due to social and cultural reasons. The requirements for a simple eye bank to manage the supply for a local hospital are minimal. What is the most important is the donor base. In Sri Lanka nurtured in the traditions of Theravada Buddhism the donor base was easy to prepare. We had no difficulties with Christians and Hindus. For Muslims there are Fatwas in favour of donating eyes. But we always found them to be a reluctant group. But in predominantly Muslim countries, it is imperative that social workers should take up this issue, so those thousands may be helped. In all areas where attempts are made to procure comeas, it is important to have a day-and-night service available at short notice to collect any eyes offered. A trained technician with sterilised instruments to obtain eyes and blood sample must be available at a convenient location preferably in a large hospital. Even in places where the supply is infrequent, it is essential to have the readily-sterilised instruments to proceed to a donor site at short notice. To get eyes, general publicity in mass media alone is not sufficient. Such publicity makes people aware of the need for donor eyes and where a technician/doctor is available. What is more important is to canvass personally after a person has died For this purpose trained social workers may be employed, or the technician can do the motivation, as we do in Sri Lanka. Once eyes are removed, it is essential to pay careful attention to the appearance of the cadaver. It should not (and need not) cause any deformity as such event has a profound negative effect on the campaign. Many different preservation methods have been used over the years. Mc Carey-Kaufmann (MK) medium has been the standard for many years, and gives a life span of 4-5 days. The formula

  7. Efficacious and safe tissue-selective controlled gene therapy approaches for the cornea.

    Directory of Open Access Journals (Sweden)

    Rajiv R Mohan

    2011-04-01

    Full Text Available Untargeted and uncontrolled gene delivery is a major cause of gene therapy failure. This study aimed to define efficient and safe tissue-selective targeted gene therapy approaches for delivering genes into keratocytes of the cornea in vivo using a normal or diseased rabbit model. New Zealand White rabbits, adeno-associated virus serotype 5 (AAV5, and a minimally invasive hair-dryer based vector-delivery technique were used. Fifty microliters of AAV5 titer (6.5×10(12 vg/ml expressing green fluorescent protein gene (GFP was topically applied onto normal or diseased (fibrotic or neovascularized rabbit corneas for 2-minutes with a custom vector-delivery technique. Corneal fibrosis and neovascularization in rabbit eyes were induced with photorefractive keratectomy using excimer laser and VEGF (630 ng using micropocket assay, respectively. Slit-lamp biomicroscopy and immunocytochemistry were used to confirm fibrosis and neovascularization in rabbit corneas. The levels, location and duration of delivered-GFP gene expression in the rabbit stroma were measured with immunocytochemistry and/or western blotting. Slot-blot measured delivered-GFP gene copy number. Confocal microscopy performed in whole-mounts of cornea and thick corneal sections determined geometric and spatial localization of delivered-GFP in three-dimensional arrangement. AAV5 toxicity and safety were evaluated with clinical eye exam, stereomicroscopy, slit-lamp biomicroscopy, and H&E staining. A single 2-minute AAV5 topical application via custom delivery-technique efficiently and selectively transduced keratocytes in the anterior stroma of normal and diseased rabbit corneas as evident from immunocytochemistry and confocal microscopy. Transgene expression was first detected at day 3, peaked at day 7, and was maintained up to 16 weeks (longest tested time point. Clinical and slit-lamp eye examination in live rabbits and H&E staining did not reveal any significant changes between AAV5

  8. Why Does the Healthy Cornea Resist Pseudomonas aeruginosa Infection?

    Science.gov (United States)

    Evans, David J.; Fleiszig, Suzanne M. J.

    2013-01-01

    Purpose To provide our perspective on why the cornea is resistant to infection based on our research results with Pseudomonas aeruginosa. Perspective We focus on our current understanding of the interplay between bacteria, tear fluid and the corneal epithelium that determine health as the usual outcome, and propose a theoretical model for how contact lens wear might change those interactions to enable susceptibility to P. aeruginosa infection. Methods Use of “null-infection” in vivo models, cultured human corneal epithelial cells, contact lens-wearing animal models, and bacterial genetics help to elucidate mechanisms by which P. aeruginosa survive at the ocular surface, adheres, and traverses multilayered corneal epithelia. These models also help elucidate the molecular mechanisms of corneal epithelial innate defense. Results and Discussion Tear fluid and the corneal epithelium combine to make a formidable defense against P. aeruginosa infection of the cornea. Part of that defense involves the expression of antimicrobials such as β-defensins, the cathelicidin LL-37, cytokeratin-derived antimicrobial peptides, and RNase7. Immunomodulators such as SP-D and ST2 also contribute. Innate defenses of the cornea depend in part on MyD88, a key adaptor protein of TLR and IL-1R signaling, but the basal lamina represents the final barrier to bacterial penetration. Overcoming these defenses involves P. aeruginosa adaptation, expression of the type three secretion system, proteases, and P. aeruginosa biofilm formation on contact lenses. Conclusion After more than two decades of research focused on understanding how contact lens wear predisposes to P. aeruginosa infection, our working hypothesis places blame for microbial keratitis on bacterial adaptation to ocular surface defenses, combined with changes to the biochemistry of the corneal surface caused by trapping bacteria and tear fluid against the cornea under the lens. PMID:23601656

  9. Anterior segment optical coherence tomography for evaluation of cornea and ocular surface

    Directory of Open Access Journals (Sweden)

    Mittanamalli S Sridhar

    2018-01-01

    Full Text Available Current corneal assessment technologies make the process of corneal evaluation extremely fast and simple. Several devices and technologies allow to explore and manage patients better. Optical coherence tomography (OCT technology has evolved over the years, and hence a detailed evaluation of anterior segment (AS structures such as cornea, conjunctiva, tear meniscus, anterior chamber, iris, and crystalline lens has been possible in a noncontact and safe procedure. The purpose of this special issue is to present and update in the evaluation of cornea and ocular surface, and this paper reviews a description of the AS-OCT, presenting the technology and common clinical uses of OCT in the management of diseases involving cornea and ocular surface to provide an updated information of the clinical recommendations of this technique in eye care practice.

  10. [The value of methods for morphofunctional analysis of cornea in cataract surgery].

    Science.gov (United States)

    Borodina, N B; Kobzova, M V; Musaeva, G M

    2011-01-01

    The characteristics of morphofunctional status of cornea after extracapsular cataract extraction and phakoemulsification with IOL implantation (30 and 58 operations respectively) were analyzed in detail using up-to-date diagnostic techniques. The results of examination using developed algorithm including study of light transmission, refraction and protective function of cornea show advantage of microinvasive ultrasound technique of cataract surgery in terms of minimal impact on corneal structure, optical and biomechanical characteristics.

  11. Second Harmonic Generation Imaging Analysis of Collagen Arrangement in Human Cornea.

    Science.gov (United States)

    Park, Choul Yong; Lee, Jimmy K; Chuck, Roy S

    2015-08-01

    To describe the horizontal arrangement of human corneal collagen bundles by using second harmonic generation (SHG) imaging. Human corneas were imaged with an inverted two photon excitation fluorescence microscope. The excitation laser (Ti:Sapphire) was tuned to 850 nm. Backscatter signals of SHG were collected through a 425/30-nm bandpass emission filter. Multiple, consecutive, and overlapping image stacks (z-stacks) were acquired to generate three dimensional data sets. ImageJ software was used to analyze the arrangement pattern (irregularity) of collagen bundles at each image plane. Collagen bundles in the corneal lamellae demonstrated a complex layout merging and splitting within a single lamellar plane. The patterns were significantly different in the superficial and limbal cornea when compared with deep and central regions. Collagen bundles were smaller in the superficial layer and larger in deep lamellae. By using SHG imaging, the horizontal arrangement of corneal collagen bundles was elucidated at different depths and focal regions of the human cornea.

  12. Optical coherent tomography measurements of the diffusion rate of water and drugs in an isolated and whole cornea

    International Nuclear Information System (INIS)

    Larin, Kirill V; Ghosn, M G

    2006-01-01

    The passive diffusion of drugs through the epithelial surfaces of an eye (the most widespread method for medical treatment of various diseases) is considered. The permeability of water and drugs through rabbit cornea was measured in the isolated cornea (separate from an eye) and in the whole cornea. The permeability coefficients of water and dexamethasone were estimated by the method of optical coherence tomography (OCT). Because multiple photon scattering introduces noise and distortions to the OCT signal, measurements were performed at depths up to 500 μm where most likely single scattering of light occurs in cornea. It is shown that the permeability coefficients in the isolated and whole cornea strongly differ from each other. For example, the water permeability in the isolated and whole cornea is (7.09±0.12)x10 -5 and (1.71±0.51)x10 -5 cm s -1 , respectively. (special issue devoted to multiple radiation scattering in random media)

  13. Crosslinked collagen–gelatin–hyaluronic acid biomimetic film for cornea tissue engineering applications

    International Nuclear Information System (INIS)

    Liu, Yang; Ren, Li; Wang, Yingjun

    2013-01-01

    Cornea disease may lead to blindness and keratoplasty is considered as an effective treatment method. However, there is a severe shortage of donor corneas worldwide. This paper presents the crosslinked collagen (Col)–gelatin (Gel)–hyaluronic acid (HA) films developed by making use of 1-ethyl-3-(3-dimethyl aminopropyl) carbodiimide (EDC) and N-hydroxysuccinimide (NHS) as the crosslinker. The test results on the physical and biological properties indicate that the CGH631 film (the mass ratio of Col:Gel:HA = 6:3:1) has appropriate optical performance, hydrophilicity and mechanical properties. The diffusion properties of the CGH631 film to NaCl and tryptophan are also satisfactory and the measured data are 2.43 × 10 −6 cm 2 /s and 7.97 × 10 −7 cm 2 /s, respectively. In addition, cell viability studies demonstrate that the CGH631 film has good biocompatibility, on which human corneal epithelial cells attached and proliferated well. This biocompatible film may have potential use in cornea tissue engineering. - Highlights: ► Crosslinked collagen–gelatin–hyaluronic acid films were fabricated in this study. ► The film had appropriate physical properties. ► Diffusion coefficient of the film was comparable with the human cornea. ► HCEC viability studies confirmed the biocompatibility of the film.

  14. Wavelength-dependent ultraviolet induction of cyclobutane pyrimidine dimers in the human cornea.

    Science.gov (United States)

    Mallet, Justin D; Rochette, Patrick J

    2013-08-01

    Exposition to ultraviolet (UV) light is involved in the initiation and the progression of skin cancer. The genotoxicity of UV light is mainly attributed to the induction of cyclobutane pyrimidine dimers (CPDs), the most abundant DNA damage generated by all UV types (UVA, B and C). The human cornea is also exposed to the harmful UV radiations, but no UV-related neoplasm has been reported in this ocular structure. The probability that a specific DNA damage leads to a mutation and eventually to cellular transformation is influenced by its formation frequency. To shed light on the genotoxic effect of sunlight in the human eye, we have analyzed CPD induction in the cornea and the iris following irradiation of ex vivo human eyes with UVA, B or C. The extent of CPD induction was used to establish the penetrance of the different UV types in the human cornea. We show that UVB- and UVC-induced CPDs are concentrated in the corneal epithelium and do not penetrate deeply beyond this corneal layer. On the other hand, UVA wavelengths penetrate deeper and induce CPDs in the entire cornea and in the first layers of the iris. Taken together, our results are undoubtedly an important step towards better understanding the consequences of UV exposure to the human eye.

  15. Physical structure of artificial seagrass affects macrozoobenthic community recruitment

    Science.gov (United States)

    Ambo-Rappe, R.; Rani, C.

    2018-03-01

    Seagrass ecosystems are important in supporting marine biodiversity. However, the worldwide decline in seagrass areas due to anthropogenic factors leads to a decrease in the marine biodiversity they can support. There is growing awareness of the need for concepts to conserve and/or rehabilitate seagrass ecosystems. One option is to create artificial seagrass to provide a physical structure for the marine organisms to colonize. The objective of this research was to analyze the effect of some artificial seagrasses and seagrass transplants on marine biodiversity, with a focus on the macrozoobenthic community. The experimental design compared two types of artificial seagrass (polypropylene ribbons and shrub-shaped plastic leaves), and seagrass transplants from nearby seagrass meadows. The experimental plots were 4 x 4 m2 with 3 replicates. Macrozoobenthic communities were sampled fortnightly for 3.5 months. At the end of the experiment, makrozoobenthos were also sampled from a natural seagrass bed nearby. Of 116 macrozoobenthic species in the artificial seagrass plots, 91 were gastropods. The density of the macrobenthic fauna increased from the beginning to the end of the study in all treatments, but the increase was only significant for the artificial seagrass treatment (i.e. shrub-like plastic leaves). There was a distinct separation between the macrozoobenthic community structure found in the restoration plots (artificial seagrass and transplanted seagrass) compared to natural seagrass beds.

  16. Computational modeling of drug transport across the in vitro cornea.

    Science.gov (United States)

    Pak, Joseph; Chen, Z J; Sun, Kay; Przekwas, Andrzej; Walenga, Ross; Fan, Jianghong

    2018-01-01

    A novel quasi-3D (Q3D) modeling approach was developed to model networks of one dimensional structures like tubes and vessels common in human anatomy such as vascular and lymphatic systems, neural networks, and respiratory airways. Instead of a branching network of the same tissue type, this approach was extended to model an interconnected stack of different corneal tissue layers with membrane junction conditions assigned between the tissues. The multi-laminate structure of the cornea presents a unique barrier design and opportunity for investigation using Q3D modeling. A Q3D model of an in vitro rabbit cornea was created to simulate the drug transport across the cornea, accounting for transcellular and paracellular pathways of passive and convective drug transport as well as physicochemistry of lipophilic partitioning and protein binding. Lipophilic Rhodamine B and hydrophilic fluorescein were used as drug analogs. The model predictions for both hydrophilic and lipophilic tracers were able to match the experimental measurements along with the sharp discontinuities at the epithelium-stroma and stroma-endothelium interfaces. This new modeling approach was successfully applied towards pharmacokinetic modeling for use in topical ophthalmic drug design. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Corneal-protective effects of an artificial tear containing sodium hyaluronate and castor oil on a porcine short-term dry eye model.

    Science.gov (United States)

    Hasegawa, Takashi; Amako, Hideki; Yamamoto, Takeshi; Tazawa, Mariko; Sakamoto, Yuji

    2014-09-01

    The corneal-protective effects of an artificial tear containing sodium hyaluronate (SH) and castor oil (CO) were evaluated on a porcine short-term dry eye model. Fresh porcine eyes with an intact cornea were treated with an artificial tear of saline, SH solution (0.1%, 0.5% or 1%), CO solution (0.5%, 1% or 5%) or a mixture solution containing 0.5% SH and 1% CO and then desiccated for 60, 90 or 180 min. To assess corneal damage, the eyes were stained with methylene blue (MB) or lissamine green (LG). The staining score of MB, absorbance of MB extracted from the cornea and staining density of LG increased significantly with increasing desiccation time in untreated and all artificial tear-treated eyes, although there were no significant differences in staining scores and absorbance of MB between eyes treated continuously with saline and 1% SH-treated ones at 60 and 90 min of desiccation or the mixture-treated eyes at 60 min of desiccation. No significant differences in the staining density of LG were also found between continuous saline-treated eyes and ones desiccated for 60 min and treated with 1% SH and the mixture. Mild cytoplasmic vacuolations were histopathologically observed in the basal and wing cells in eyes desiccated for 60 min and treated with 1% SH and the mixture. The mixture solution containing 0.5% SH and 1% CO has protective effects against corneal desiccation similar to those of 1% SH and would be helpful as an artificial tear.

  18. The effect of single and repeated UVB radiation on rabbit cornea.

    Science.gov (United States)

    Fris, Miroslav; Tessem, May-Britt; Cejková, Jitka; Midelfart, Anna

    2006-12-01

    Cumulative effect of ultraviolet radiation (UVR) is an important aspect of UV corneal damage. The purpose of this study was to apply high resolution magic angle spinning proton nuclear magnetic resonance (HR-MAS 1H NMR) spectroscopy to evaluate the effect of single and repeated UV radiation exposure of the same overall dose on the rabbit cornea. Corneal surfaces of 24 normal rabbit eyes were examined for the effects of UVB exposure (312 nm). In the first group (UVB1), animals were irradiated with a single dose (3.12 J/cm2; 21 min) of UVB radiation. The animals in the second group (UVB2) were irradiated three times for 7 min every other day (dose of 1.04 J/cm2; days 1, 3, 5) to give the same overall dose (3.12 J/cm2). The third group served as an untreated control group. One day after the last irradiation, the animals were sacrificed, and the corneas were removed and frozen. HR-MAS 1H NMR spectra from intact corneas were obtained. Special grouping patterns among the tissue samples and the relative percentage changes in particular metabolite concentrations were evaluated using modern statistical methods (multivariate analysis, one-way ANOVA). The metabolic profile of both groups of UVB-irradiated samples was significantly different from the control corneas. Substantial decreases in taurine, hypo-taurine and choline-derivatives concentrations and substantial elevation in glucose and betaine levels were observed following the UVR exposure. There was no significant difference between the effect of a single and repeated UVB irradiation of the same overall dose. For the first time, the effects of single and repeated UVR doses on the metabolic profile of the rabbit cornea were analysed and compared. The combination of HR-MAS 1H NMR spectroscopy and modern statistical methods (multivariate analysis, one-way ANOVA) proved suitable to assess the overall view of the metabolic alterations in the rabbit corneal tissue following UVB radiation exposure.

  19. Thermodynamic measurement after cooling the cornea with intact epithelium and lid manipulation.

    Science.gov (United States)

    de Ortueta, Diego; Magnago, Thomas; Arba-Mosquera, Samuel

    2015-01-01

    To characterize the rate of change of ocular surface temperature (OST) under lid manipulation after cooling the intact cornea with balanced salt solution (BSS). In a patient for refractive surgery, prior to the ablation, the temperature of the cornea was continuously recorded with a high speed infrared (350Hz) camera. Two millilitre of chilled BSS with a temperature of 8.6°Celsius (°C) was instilled for about 3s. Using exponential functions, the three contributions have been determined, subjacent corneal layers, environment, and chilled BSS. The mean temperature of the cornea preoperatively was 34.5°C. After applying the chilled BSS the temperature decreased about 14°C down to an OST of 20°C and the time needed afterwards to get the normal (OST) temperature of about 30°C was 40s. Due to the inserted speculum and missing blink, OST did not reach the original OST of 34.5°C and faded at about 32.5°C. According to our best fitted model, absolute value of each contributing component was 31.4°C (subjacent corneal layers), 26.8°C (environment) and 8.6°C (BSS). Applying chilled BSS to the cornea quickly reduces the temperature of the cornea with a thermal relaxation time of 3s and a amplitude decrease of 8.6°C. This together with a relaxation time of 7s for subjacent corneal layers, and 184s for environment after instillation of BSS combined with a well-controlled environment provides a period of 40s of corneal temperature below baseline, which may be of clinical benefit when applying chilled BSS immediately before or immediately after ablation. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  20. [Results of an internet-based survey amongst members of the German Ophthalmological Society concerning postmortem cornea donation].

    Science.gov (United States)

    Uhlig, C E; Promesberger, J; Hirschfeld, G; Koch, R; Reinhard, T; Seitz, B

    2012-12-01

    Analysis of willingness for postmortem cornea donation by professionals in ophthalmology and their motives in favor of or against donation. 3887 members of the German Ophthalmological Society received an anonymous questionnaire concerning sociodemographic background, physical health, experiences with organ explantation and their former engagement and motives concerning organ and cornea donation. 722 of the questionnaires were partially and 533 completely answered with an average willingness for cornea donation of 79.4%. Significant parameters for cornea donation were gender, former experience with organ explantation, ophthalmological health and fear of false diagnosis of brain death, worse medical treatment or organ commercialization. Of the participants 53.9% suggested the internet as a favorite source of information in this matter. The factors which had a significant impact on cornea donation in this survey seem to be mainly a result of insufficient information. Detailed information regarding this topic should preferentially be presented on internet pages of professional societies and could probably increase donation approval of DOG members.

  1. Plastic compressed collagen as a novel carrier for expanded human corneal endothelial cells for transplantation.

    Directory of Open Access Journals (Sweden)

    Hannah J Levis

    Full Text Available Current treatments for reversible blindness caused by corneal endothelial cell failure involve replacing the failed endothelium with donor tissue using a one donor-one recipient strategy. Due to the increasing pressure of a worldwide donor cornea shortage there has been considerable interest in developing alternative strategies to treat endothelial disorders using expanded cell replacement therapy. Protocols have been developed which allow successful expansion of endothelial cells in vitro but this approach requires a supporting material that would allow easy transfer of cells to the recipient. We describe the first use of plastic compressed collagen as a highly effective, novel carrier for human corneal endothelial cells. A human corneal endothelial cell line and primary human corneal endothelial cells retained their characteristic cobblestone morphology and expression of tight junction protein ZO-1 and pump protein Na+/K+ ATPase α1 after culture on collagen constructs for up to 14 days. Additionally, ultrastructural analysis suggested a well-integrated endothelial layer with tightly opposed cells and apical microvilli. Plastic compressed collagen is a superior biomaterial in terms of its speed and ease of production and its ability to be manipulated in a clinically relevant manner without breakage. This method provides expanded endothelial cells with a substrate that could be suitable for transplantation allowing one donor cornea to potentially treat multiple patients.

  2. Crosslinked collagen-gelatin-hyaluronic acid biomimetic film for cornea tissue engineering applications

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yang; Ren, Li, E-mail: psliren@scut.edu.cn; Wang, Yingjun, E-mail: imwangyj@163.com

    2013-01-01

    Cornea disease may lead to blindness and keratoplasty is considered as an effective treatment method. However, there is a severe shortage of donor corneas worldwide. This paper presents the crosslinked collagen (Col)-gelatin (Gel)-hyaluronic acid (HA) films developed by making use of 1-ethyl-3-(3-dimethyl aminopropyl) carbodiimide (EDC) and N-hydroxysuccinimide (NHS) as the crosslinker. The test results on the physical and biological properties indicate that the CGH631 film (the mass ratio of Col:Gel:HA = 6:3:1) has appropriate optical performance, hydrophilicity and mechanical properties. The diffusion properties of the CGH631 film to NaCl and tryptophan are also satisfactory and the measured data are 2.43 Multiplication-Sign 10{sup -6} cm{sup 2}/s and 7.97 Multiplication-Sign 10{sup -7} cm{sup 2}/s, respectively. In addition, cell viability studies demonstrate that the CGH631 film has good biocompatibility, on which human corneal epithelial cells attached and proliferated well. This biocompatible film may have potential use in cornea tissue engineering. - Highlights: Black-Right-Pointing-Pointer Crosslinked collagen-gelatin-hyaluronic acid films were fabricated in this study. Black-Right-Pointing-Pointer The film had appropriate physical properties. Black-Right-Pointing-Pointer Diffusion coefficient of the film was comparable with the human cornea. Black-Right-Pointing-Pointer HCEC viability studies confirmed the biocompatibility of the film.

  3. Mesothelial proteins are expressed in the human cornea

    Czech Academy of Sciences Publication Activity Database

    Jirsová, K.; Neuwirth, Aleš; Kalašová, S.; Veselá, V.; Merjava, S.

    2010-01-01

    Roč. 91, č. 5 (2010), s. 623-629 ISSN 0014-4835 Institutional research plan: CEZ:AV0Z50520514 Keywords : cornea * HBME-1 (Hector Battifora mesothelial cell-1) protein * calbindin 2 Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 2.817, year: 2010

  4. Raman Microscopy: A Noninvasive Method to Visualize the Localizations of Biomolecules in the Cornea.

    Science.gov (United States)

    Kaji, Yuichi; Akiyama, Toshihiro; Segawa, Hiroki; Oshika, Tetsuro; Kano, Hideaki

    2017-11-01

    In vivo and in situ visualization of biomolecules without pretreatment will be important for diagnosis and treatment of ocular disorders in the future. Recently, multiphoton microscopy, based on the nonlinear interactions between molecules and photons, has been applied to reveal the localizations of various molecules in tissues. We aimed to use multimodal multiphoton microscopy to visualize the localizations of specific biomolecules in rat corneas. Multiphoton images of the corneas were obtained from nonlinear signals of coherent anti-Stokes Raman scattering, third-order sum frequency generation, and second-harmonic generation. The localizations of the adhesion complex-containing basement membrane and Bowman layer were clearly visible in the third-order sum frequency generation images. The fine structure of type I collagen was observed in the corneal stroma in the second-harmonic generation images. The localizations of lipids, proteins, and nucleic acids (DNA/RNA) was obtained in the coherent anti-Stokes Raman scattering images. Imaging technologies have progressed significantly and been applied in medical fields. Optical coherence tomography and confocal microscopy are widely used but do not provide information on the molecular structure of the cornea. By contrast, multiphoton microscopy provides information on the molecular structure of living tissues. Using this technique, we successfully visualized the localizations of various biomolecules including lipids, proteins, and nucleic acids in the cornea. We speculate that multiphoton microscopy will provide essential information on the physiological and pathological conditions of the cornea, as well as molecular localizations in tissues without pretreatment.

  5. Xanthelasmata, arcus corneae, and ischaemic vascular disease and death in general population: prospective cohort study

    DEFF Research Database (Denmark)

    Christoffersen, Mette; Frikke-Schmidt, Ruth; Schnohr, Peter

    2011-01-01

    To test the hypothesis that xanthelasmata and arcus corneae, individually and combined, predict risk of ischaemic vascular disease and death in the general population.......To test the hypothesis that xanthelasmata and arcus corneae, individually and combined, predict risk of ischaemic vascular disease and death in the general population....

  6. Differential expression and processing of transforming growth factor beta induced protein (TGFBIp) in the normal human cornea during postnatal development and aging

    DEFF Research Database (Denmark)

    Karring, Henrik; Runager, Kasper; Valnickova, Zuzana

    2010-01-01

    Transforming growth factor beta induced protein (TGFBIp, also named keratoepithelin) is an extracellular matrix protein abundant in the cornea. The purpose of this study was to determine the expression and processing of TGFBIp in the normal human cornea during postnatal development and aging...... trimming events from the N-terminus of mature TGFBIp generate TGFBIp isoforms which form a similar "zig-zag" pattern when separated by 2-D polyacrylamide gel electrophoresis (PAGE). This study shows that in humans TGFBIp is more abundant in mature corneas than in the developing cornea...... and that the processing of TGFBIp changes during postnatal development of the cornea. In addition, TGFBIp appears to be degraded in a highly orchestrated manner in the normal human cornea with the resulting C-terminal fragments being retained in the cornea. The age-related changes in the expression and processing...

  7. In vivo 3D measurement of moxifloxacin and gatifloxacin distributions in the mouse cornea using multiphoton microscopy

    Science.gov (United States)

    Lee, Seunghun; Lee, Jun Ho; Park, Jin Hyoung; Yoon, Yeoreum; Chung, Wan Kyun; Tchah, Hungwon; Kim, Myoung Joon; Kim, Ki Hean

    2016-05-01

    Moxifloxacin and gatifloxacin are fourth-generation fluoroquinolone antibiotics used in the clinic to prevent or treat ocular infections. Their pharmacokinetics in the cornea is usually measured from extracted ocular fluids or tissues, and in vivo direct measurement is difficult. In this study multiphoton microscopy (MPM), which is a 3D optical microscopic technique based on multiphoton fluorescence, was applied to the measurement of moxifloxacin and gatifloxacin distribution in the cornea. Intrinsic multiphoton fluorescence properties of moxifloxacin and gatifloxacin were characterized, and their distributions in mouse cornea in vivo were measured by 3D MPM imaging. Both moxifloxacin and gatifloxacin had similar multiphoton spectra, while moxifloxacin had stronger fluorescence than gatifloxacin. MPM imaging of mouse cornea in vivo showed (1) moxifloxacin had good penetration through the superficial corneal epithelium, while gatifloxacin had relatively poor penetration, (2) both ophthalmic solutions had high intracellular distribution. In vivo MPM results were consistent with previous studies. This study demonstrates the feasibility of MPM as a method for in vivo direct measurement of moxifloxacin and gatifloxacin in the cornea.

  8. Effects of genipin corneal crosslinking in rabbit corneas.

    Science.gov (United States)

    Avila, Marcel Y; Narvaez, Mauricio; Castañeda, Juan P

    2016-07-01

    To evaluate the effect of genipin, a natural crosslinking agent, in rabbit eyes. Department of Ophthalmology, Universidad Nacional de Colombia Centro de Tecnologia Oftalmica, Bogotá, Colombia. Experimental study. Ex vivo rabbit eyes (16; 8 rabbits) were treated with genipin 1.00%, 0.50%, and 0.25% for 5 minutes with a vacuum device to increase corneal permeability. Penetration was evaluated using Scheimpflug pachymetry (Pentacam). In the in vivo model (20 rabbits; 1 eye treated, 1 eye with vehicle), corneas were crosslinked with genipin as described. Corneal curvature, corneal pachymetry, and intraocular pressure (IOP) assessments as well as slitlamp examinations were performed 0, 7, 30, and 60 days after treatment. In the ex vivo model, Scheimpflug pachymetry showed deep penetration in the rabbit corneas with an increase in corneal density and a dose-dependent relationship. Corneal flattening was observed in treated eyes (mean 4.4 diopters ± 0.5 [SD]) compared with the control eyes. Pachymetry and IOP were stable in all evaluations. No eye showed toxicity in the anterior chamber or in the lens. Corneal crosslinking induced by genipin produced significant flattening of the cornea with no toxicity in rabbit eyes. This crosslinking could be useful in the treatment of corneal ectasia and in the modification of corneal curvature. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Therapeutic effect of para aminobenzoic acid (PABA) on the rat cornea administered in different ways after x-irradiation

    International Nuclear Information System (INIS)

    Panova, I.G.; Mel'nikova, I.I.; Stroeva, O.G.

    1997-01-01

    Comparative analysis of cytological state of nuclear apparatus in the mice cornea basal layer is carried out by two various method of introducing the para-aminobenzoic acid (PABA) after x-ray irradiation: 1) subcutaneous injections and 2) application of the solution on the cornea. The fact that PABA produced medicinal effect on the cornea of the irradiated mice by subcutaneous injections, shows that this action proceeds on the whole-body level

  10. Multiparameter thermo-mechanical OCT-based characterization of laser-induced cornea reshaping

    Science.gov (United States)

    Zaitsev, Vladimir Yu.; Matveyev, Alexandr L.; Matveev, Lev A.; Gelikonov, Grigory V.; Vitkin, Alex; Omelchenko, Alexander I.; Baum, Olga I.; Shabanov, Dmitry V.; Sovetsky, Alexander A.; Sobol, Emil N.

    2017-02-01

    Phase-sensitive optical coherence tomography (OCT) is used for visualizing dynamic and cumulative strains and corneashape changes during laser-produced tissue heating. Such non-destructive (non-ablative) cornea reshaping can be used as a basis of emerging technologies of laser vision correction. In experiments with cartilaginous samples, polyacrilamide phantoms and excised rabbit eyes we demonstrate ability of the developed OCT system to simultaneously characterize transient and cumulated strain distributions, surface displacements, scattering tissue properties and possibility of temperature estimation via thermal-expansion measurements. The proposed approach can be implemented in perspective real-time OCT systems for ensuring safety of new methods of laser reshaping of cornea.

  11. Cholesterol biosynthesis by the cornea. Comparison of rates of sterol synthesis with accumulation during early development

    International Nuclear Information System (INIS)

    Cenedella, R.J.; Fleschner, C.R.

    1989-01-01

    The origin of the cholesterol needed by the cornea for growth and cell turnover was addressed by comparing absolute rates of sterol synthesis with rates of sterol accumulation during early development of the rabbit. Linearity of incorporation of 3 H 2 O and [ 14 C]mevalonate into digitonin-precipitable sterols with time of incubation in vitro and a lack of accumulation of 14 C in intermediates of sterol biosynthesis indicated that tritiated water can validly be used to measure rates of sterol synthesis by the cornea. The rate of sterol synthesis per unit weight of rabbit cornea was constant between 14 and 60 days of age at an average 1.03 nmol of 3 H of 3 H 2 O incorporated/mg dry cornea per 8 h. Essentially all of the synthesized cholesterol and most of the cholesterol mass was present in corneal epithelium. The cumulative sterol synthesized over the 46-day period studied exceeded the observed rate of cholesterol accumulation by sixfold. Cholesterol synthesized in excess of the growth requirement was likely used to support turnover of the epithelium which was estimated at 9 days. Removal of cholesterol from the cornea by excretion into tear fluid and clearance by high density lipoproteins are also considered

  12. Air-pulse OCE for assessment of age-related changes in mouse cornea in vivo

    International Nuclear Information System (INIS)

    Li, Jiasong; Wang, Shang; Singh, M; Larin, K V; Aglyamov, S; Emelianov, S; Twa, M D

    2014-01-01

    We demonstrate the use of phase-stabilized swept source optical coherence elastography (PhS-SSOCE) to assess the relaxation rate of deformation created by a focused air-pulse in tissue-mimicking gelatin phantoms of various concentrations and mouse corneas of different ages in vivo. The results show that the relaxation rate can be quantified and is different for gels with varying concentrations of gelatin and mouse corneas of different ages. The results indicate that gel phantoms with higher concentrations of gelatin as well as older mouse corneas have faster relaxation rates indicating stiffer material. This non-contact and non-invasive measurement technique utilizes low surface displacement amplitude (in µm scale) for tissue excitation and, therefore, can be potentially used to study the biomechanical properties of ocular and other sensitive tissues. (letter)

  13. Artificial Muscle Kits for the Classroom

    Science.gov (United States)

    2004-01-01

    Commonly referred to as "artificial muscles," electroactive polymer (EAP) materials are lightweight strips of highly flexible plastic that bend or stretch when subjected to electric voltage. EAP materials may prove to be a substitution for conventional actuation components such as motors and gears. Since the materials behave similarly to biological muscles, this emerging technology has the potential to develop improved prosthetics and biologically-inspired robots, and may even one day replace damaged human muscles. The practical application of artificial muscles provides a challenge, however, since the material requires improved effectiveness and durability before it can fulfill its potential.

  14. Expression of multidrug resistance associated protein 5 (MRP5) on cornea and its role in drug efflux.

    Science.gov (United States)

    Karla, Pradeep K; Quinn, Tim L; Herndon, Betty L; Thomas, Priscilla; Pal, Dhananjay; Mitra, Ashim

    2009-04-01

    The purpose of this manuscript is to investigate the presence of nucleoside/nucleotide efflux transporter in cornea and to evaluate the role in ocular drug efflux. RT-PCR, immunoprecipitation followed by Western blot analysis and immunostaining were employed to establish molecular presence of multidrug resistance associated protein 5 (MRP5) on cornea. Corneal efflux by MRP5 was studied with bis(POM)-PMEA and acyclovir using rabbit and human corneal epithelial cells along with MRP5 over expressing cells (MDCKII-MRP5). Ex vivo studies using excised rabbit cornea and in vivo ocular microdialysis in male New Zealand white rabbits were used to further evaluate the role of MRP5 in conferring ocular drug resistance. RT-PCR confirms the expression of MRP5 in both rabbit and human corneal epithelial cells along with MDCKII-MRP5 cells. Immunoprecipitation followed by Western blot analysis using a rat (M511-54) monoclonal antibody that reacts with human epitope confirms the expression of MRP5 protein in human corneal epithelial cells and MDCKII-MRP5 cells. Immunostaining performed on human cornea indicates the localization of this efflux pump on both epithelium and endothelium. Efflux studies reveal that depletion of ATP decreased PMEA efflux significantly. MRP5 inhibitors also diminished PMEA and acyclovir efflux. However, depletion of glutathione did not alter efflux. MDR1 and MRP2 did not contribute to PMEA efflux. However, MRP2 is involved in acyclovir efflux while MDR1 do not participate in this process. TLC/autoradiography suggested the conversion of bis(POM)-PMEA to PMEA in rabbit and human corneal epithelial cells. Two well known antiglaucoma drugs, bimatoprost and latanoprost were rapidly effluxed by MRP5. Ex vivo study on intact rabbit corneas demonstrated accumulation of PMEA in cornea in the presence of ATP-depleting medium. In vivo ocular pharmacokinetics also revealed a significant increase in maximum aqueous humor concentration (C(max)) and area under the

  15. Optics of the human cornea influence the accuracy of stereo eye-tracking methods: a simulation study

    NARCIS (Netherlands)

    Barsingerhorn, A.D.; Boonstra, F.N.; Goossens, H.H.L.M.

    2017-01-01

    Current stereo eye-tracking methods model the cornea as a sphere with one refractive surface. However, the human cornea is slightly aspheric and has two refractive surfaces. Here we used ray-tracing and the Navarro eye-model to study how these optical properties affect the accuracy of different

  16. Effect of glaucoma tube shunt parameters on cornea endothelial cells in patients with Ahmed valve implants.

    Science.gov (United States)

    Koo, Euna B; Hou, Jing; Han, Ying; Keenan, Jeremy D; Stamper, Robert L; Jeng, Bennie H

    2015-01-01

    The aim of this study was to assess the effect of various tube parameters on corneal endothelial cell density (ECD) after insertion of Ahmed valves. Thirty-nine eyes of 33 patients with previous superotemporal (ST) Ahmed valve implantation and 20 eyes of 13 participants with previous uncomplicated phacoemulsification and intraocular lens implantation but no history of glaucoma surgery were evaluated. Various tube parameters were measured with anterior segment optical coherence tomography. ST, central, and inferonasal (IN) ECD and pachymetry were measured. Endothelial cell loss and corneal thickness in the ST cornea was compared with those in the IN cornea. The mean age of the operated patients was 58 ± 22 years, and the mean time since glaucoma surgery was 2.5 ± 2.6 years. Thirty-two of the 39 study eyes were pseudophakic. The ECD was significantly lower in the ST endothelium than in the IN endothelium in eyes with glaucoma tube surgery (P < 0.001), although this relative reduction in ST ECD was not greater than that seen in pseudophakic control eyes (P = 0.16). In univariate analysis, tube angle relative to the cornea and distance from the tip of the tube to the cornea were significant risk factors for decreased ST endothelial cell loss when assessed relative to the IN ECD (P = 0.01 and P = 0.02, respectively). In multivariate analysis, only the distance of the tube tip to the cornea remained significantly associated with ST endothelial cell loss. Although this was a retrospective study with inherent limitations, tubes that are closer to the cornea seem to lead to increased loss of adjacent endothelial cells.

  17. Tracing the fate of limbal epithelial progenitor cells in the murine cornea.

    Science.gov (United States)

    Di Girolamo, N; Bobba, S; Raviraj, V; Delic, N C; Slapetova, I; Nicovich, P R; Halliday, G M; Wakefield, D; Whan, R; Lyons, J G

    2015-01-01

    Stem cell (SC) division, deployment, and differentiation are processes that contribute to corneal epithelial renewal. Until now studying the destiny of these cells in a living mammal has not been possible. However, the advent of inducible multicolor genetic tagging and powerful imaging technologies has rendered this achievable in the translucent and readily accessible murine cornea. K14CreER(T2)-Confetti mice that harbor two copies of the Brainbow 2.1 cassette, yielding up to 10 colors from the stochastic recombination of fluorescent proteins, were used to monitor K-14(+) progenitor cell dynamics within the corneal epithelium in live animals. Multicolored columns of cells emerged from the basal limbal epithelium as they expanded and migrated linearly at a rate of 10.8 µm/day toward the central cornea. Moreover, the permanent expression of fluorophores, passed on from progenitor to progeny, assisted in discriminating individual clones as spectrally distinct streaks containing more than 1,000 cells within the illuminated area. The centripetal clonal expansion is suggestive that a single progenitor cell is responsible for maintaining a narrow corridor of corneal epithelial cells. Our data are in agreement with the limbus as the repository for SC as opposed to SC being distributed throughout the central cornea. This is the first report describing stem/progenitor cell fate determination in the murine cornea using multicolor genetic tracing. This model represents a powerful new resource to monitor SC kinetics and fate choice under homeostatic conditions, and may assist in assessing clonal evolution during corneal development, aging, wound-healing, disease, and following transplantation. © 2014 AlphaMed Press.

  18. Atmospheric-Pressure Cold Plasma Induces Transcriptional Changes in Ex Vivo Human Corneas.

    Directory of Open Access Journals (Sweden)

    Umberto Rosani

    Full Text Available Atmospheric pressure cold plasma (APCP might be considered a novel tool for tissue disinfection in medicine since the active chemical species produced by low plasma doses, generated by ionizing helium gas in air, induces reactive oxygen species (ROS that kill microorganisms without substantially affecting human cells.In this study, we evaluated morphological and functional changes in human corneas exposed for 2 minutes (min to APCP and tested if the antioxidant n-acetyl l-cysteine (NAC was able to inhibit or prevent damage and cell death.Immunohistochemistry and western blotting analyses of corneal tissues collected at 6 hours (h post-APCP treatment demonstrated no morphological tissue changes, but a transient increased expression of OGG1 glycosylase that returned to control levels in 24 h. Transcriptome sequencing and quantitative real time PCR performed on different corneas revealed in the treated corneas many differentially expressed genes: namely, 256 and 304 genes showing expression changes greater than ± 2 folds in the absence and presence of NAC, respectively. At 6 h post-treatment, the most over-expressed gene categories suggested an active or enhanced cell functioning, with only a minority of genes specifically concerning oxidative DNA damage and repair showing slight over-expression values (<2 folds. Moreover, time-related expression analysis of eight genes up-regulated in the APCP-treated corneas overall demonstrated the return to control expression levels after 24 h.These findings of transient oxidative stress accompanied by wide-range transcriptome adjustments support the further development of APCP as an ocular disinfectant.

  19. Optics of the human cornea influence the accuracy of stereo eye-tracking methods: a simulation study.

    Science.gov (United States)

    Barsingerhorn, A D; Boonstra, F N; Goossens, H H L M

    2017-02-01

    Current stereo eye-tracking methods model the cornea as a sphere with one refractive surface. However, the human cornea is slightly aspheric and has two refractive surfaces. Here we used ray-tracing and the Navarro eye-model to study how these optical properties affect the accuracy of different stereo eye-tracking methods. We found that pupil size, gaze direction and head position all influence the reconstruction of gaze. Resulting errors range between ± 1.0 degrees at best. This shows that stereo eye-tracking may be an option if reliable calibration is not possible, but the applied eye-model should account for the actual optics of the cornea.

  20. Collagen organization in the chicken cornea and structural alterations in the retinopathy, globe enlarged (rge) phenotype--an X-ray diffraction study.

    Science.gov (United States)

    Boote, Craig; Hayes, Sally; Jones, Simon; Quantock, Andrew J; Hocking, Paul M; Inglehearn, Chris F; Ali, Manir; Meek, Keith M

    2008-01-01

    An investigation into the collagenous structure of the mature avian cornea is presented. Wide-angle X-ray diffraction is employed to assess collagen organization in 9-month-old chicken corneas. The central 2-4mm corneal region features a preponderance of fibrils directed along the superior-inferior and nasal-temporal orthogonal meridians. More peripherally the orientation of fibrils alters in favor of a predominantly tangential arrangement. The chicken cornea appears to be circumscribed by an annulus of fibrils that extends into the limbus. The natural arrangement of collagen in the chicken cornea is discussed in relation to corneal shape and the mechanical requirements of avian corneal accommodation. Equivalent data are also presented from age-matched blind chickens affected with the retinopathy, globe enlarged (rge) mutation, characterized by an abnormally thick and flat cornea. The data indicate considerable realignment and redistribution of collagen lamellae in the peripheral rge cornea. In contrast to normal chickens, no obvious tangential collagen alignment was evident in the periphery of rge corneas. In mammals, the presence of a limbal fibril annulus is believed to be important in corneal shape preservation. We postulate that corneal flattening in rge chickens may be related to biomechanical changes brought about by an alteration in collagen arrangement at the corneal periphery.

  1. Computer driven optical keratometer and method of evaluating the shape of the cornea

    Science.gov (United States)

    Baroth, Edmund C. (Inventor); Mouneimme, Samih A. (Inventor)

    1994-01-01

    An apparatus and method for measuring the shape of the cornea utilize only one reticle to generate a pattern of rings projected onto the surface of a subject's eye. The reflected pattern is focused onto an imaging device such as a video camera and a computer compares the reflected pattern with a reference pattern stored in the computer's memory. The differences between the reflected and stored patterns are used to calculate the deformation of the cornea which may be useful for pre-and post-operative evaluation of the eye by surgeons.

  2. Feasibility study of the separation of chlorinated films from plastic packaging wastes.

    Science.gov (United States)

    Reddy, Mallampati Srinivasa; Yamaguchi, Takefumi; Okuda, Tetsuji; Tsai, Tsung-Yueh; Nakai, Satoshi; Nishijima, Wataru; Okada, Mitsumasa

    2010-04-01

    This study describes the possible separation of chlorinated plastic films (PVC and PVDC) from other heavy plastic packaging waste (PPW) by selective twist formation and gravity separation. Twists formation was mechanically induced in chlorinated plastic films, whereas twist formation did not occur in PS and PET films. After twist formation, all the films had the apparent density of less than 1.0g/cm(3) and floated in water even though the true density was more than 1.0g/cm(3). However, the apparent density of the PS and the PET films increased with agitation to more than 1.0g/cm(3), whereas that of chlorinated plastic films was kept less than 1.0g/cm(3). The main reason would be the air being held inside the chlorinated plastic films which was difficult to be removed by agitation. Simple gravity separation after twist formation was applied for artificial film with 10wt.% of the chlorinated films and real PPW films with 9wt.% of the chlorinated films. About 76wt.% of the artificial PPW films and 75wt.% of real PPW films after the removal of PP and PE were recovered as settling fraction with 4.7wt.% and 3.0wt.% of chlorinated plastic films, respectively. These results indicate that simple gravity separation process after twist formation can be used to reduce the chlorinated plastic concentration from mixed heavy PPW films. Copyright 2009 Elsevier Ltd. All rights reserved.

  3. Feasibility study of the separation of chlorinated films from plastic packaging wastes

    International Nuclear Information System (INIS)

    Reddy, Mallampati Srinivasa; Yamaguchi, Takefumi; Okuda, Tetsuji; Tsai, Tsung-Yueh; Nakai, Satoshi; Nishijima, Wataru; Okada, Mitsumasa

    2010-01-01

    This study describes the possible separation of chlorinated plastic films (PVC and PVDC) from other heavy plastic packaging waste (PPW) by selective twist formation and gravity separation. Twists formation was mechanically induced in chlorinated plastic films, whereas twist formation did not occur in PS and PET films. After twist formation, all the films had the apparent density of less than 1.0 g/cm 3 and floated in water even though the true density was more than 1.0 g/cm 3 . However, the apparent density of the PS and the PET films increased with agitation to more than 1.0 g/cm 3 , whereas that of chlorinated plastic films was kept less than 1.0 g/cm 3 . The main reason would be the air being held inside the chlorinated plastic films which was difficult to be removed by agitation. Simple gravity separation after twist formation was applied for artificial film with 10 wt.% of the chlorinated films and real PPW films with 9 wt.% of the chlorinated films. About 76 wt.% of the artificial PPW films and 75 wt.% of real PPW films after the removal of PP and PE were recovered as settling fraction with 4.7 wt.% and 3.0 wt.% of chlorinated plastic films, respectively. These results indicate that simple gravity separation process after twist formation can be used to reduce the chlorinated plastic concentration from mixed heavy PPW films.

  4. [Riboflavin photoprotection with cross-linking effect in photorefractive ablation of the cornea].

    Science.gov (United States)

    Kornilovskiy, I M; Sultanova, A I; Burtsev, A A

    2016-01-01

    Photorefractive ablation is inevitably accompanied by oxidative stress of the cornea and weakening of its biomechanical and photoprotective properties. To validate the expediency of riboflavin use in photorefractive ablation for photoprotection of the cornea and cross-linking. The effects of riboflavin use in photorefractive ablation was first studied in a series of in vitro and in vivo experiments performed on 56 eyes of 28 rabbits, and then on 232 eyes of 142 patients with different degrees of myopia. Biomechanical testing of corneal samples was performed with Zwick/RoellВZ 2.5/TN1S tensile-testing machine. Transepithelial photorefractive keratectomy (TransPRK) and femtosecond laser-assisted in situ keratomileusis (Femto-LASIK) were performed on Wavelight-Allegretto200, MEL-80, and WaveLight-EX500 excimer laser systems and also VisuMax and WaveLight-FS200 femtosecond lasers. For preliminary examinations, an appropriate set of diagnostic tools was used. In vivo experiments have proved that, in the absence of conservative therapy, riboflavin is able to produce both photoprotective and cross-linking effects to the cornea. Corneal syndrome was thus reduced and re-epithelialization after TransPRK accelerated. Biomechanical testing of corneal samples revealed an increase in tolerated load from 12.9±1.4 N to 18.3±1.2 N (p=0.0002) and tensile strength from 8.6±1.7 MPa to 12.4±1.7 MPa (p=0.007). Clinical studies conducted in a group of patients with mild to moderate myopia have also confirmed the photoprotective effect of riboflavin at months 1-12 after TransPRK. There were no significant differences in uncorrected visual acuity (ranged from 0.80±0.16 to 0.85±0.15) and corrected visual acuity at baseline (0.83±0.14). Evaluation of the optical and refractive effect achieved after Femto-LASIK with riboflavin photoprotection in the fellow eye has shown that this technique is not inferior to the traditional one as to its refractive accuracy, but provides better

  5. Intra-Ocular Pressure Measurement in a Patient with a Thin, Thick or Abnormal Cornea.

    Science.gov (United States)

    Clement, Colin I; Parker, Douglas G A; Goldberg, Ivan

    2016-01-01

    Accurate measurement of intra-ocular pressure is a fundamental component of the ocular examination. The most common method of measuring IOP is by Goldmann applanation tonometry, the accuracy of which is influenced by the thickness and biomechanical properties of the cornea. Algorithms devised to correct for corneal thickness to estimate IOP oversimplify the effects of corneal biomechanics. The viscous and elastic properties of the cornea influence IOP measurements in unpredictable ways, a finding borne out in studies of patients with inherently abnormal and surgically altered corneal biomechanics. Dynamic contour tonometry, rebound tonometry and the ocular response analyzer provide useful alternatives to GAT in patients with abnormal corneas, such as those who have undergone laser vision correction or keratoplasty. This article reviews the various methods of intra-ocular pressure measurement available to the clinician and the ways in which their utility is influenced by variations in corneal thickness and biomechanics.

  6. Excimer laser ablation of the cornea

    Science.gov (United States)

    Pettit, George H.; Ediger, Marwood N.; Weiblinger, Richard P.

    1995-03-01

    Pulsed ultraviolet laser ablation is being extensively investigated clinically to reshape the optical surface of the eye and correct vision defects. Current knowledge of the laser/tissue interaction and the present state of the clinical evaluation are reviewed. In addition, the principal findings of internal Food and Drug Administration research are described in some detail, including a risk assessment of the laser-induced-fluorescence and measurement of the nonlinear optical properties of cornea during the intense UV irradiation. Finally, a survey is presented of the alternative laser technologies being explored for this ophthalmic application.

  7. Low-dose radiation effects on the evolution of chronic dystrophical processes in cornea and clouding of crystalline lens

    International Nuclear Information System (INIS)

    Gajdaj, Yu.V.; Gajdaj, V.M.

    1993-01-01

    Low-dose radiation effects on the course of chronic dystrophical processes in cornea and the dynamics of crystalline lens clouding of involution age genesis are investigated in the patients participated in Chernobyl accident response. Examples of the concrete pathological cases are considered. It was stated that the above dose effects led to exacerbation of the chronic slack dystrophical processes in cornea and intensification of the development of cornea primary dystrophy. In a number of cases the intensification of development of crystalline lens clouding takes place resulted in the cataract for 2-3 years

  8. Colocalization of Galectin-3 With CD147 Is Associated With Increased Gelatinolytic Activity in Ulcerating Human Corneas.

    Science.gov (United States)

    Cruzat, Andrea; Gonzalez-Andrades, Miguel; Mauris, Jérôme; AbuSamra, Dina B; Chidambaram, Preethi; Kenyon, Kenneth R; Chodosh, James; Dohlman, Claes H; Argüeso, Pablo

    2018-01-01

    Galectin-3 is a carbohydrate-binding protein known to promote expression of matrix metalloproteinases, a hallmark of ulceration, through interaction with the extracellular matrix metalloproteinase inducer CD147. The aim of this study was to investigate the distribution of galectin-3 in corneas of patients with ulcerative keratitis and to determine its relationship to CD147 and the presence of gelatinolytic activity. This was an observational case series involving donor tissue from 13 patients with active corneal ulceration and 6 control corneas. Fixed-frozen sections of the corneas were processed to localize galectin-3 and CD147 by immunofluorescence microscopy. Gelatinolytic activity was detected by in situ zymography. Tissue from patients with active corneal ulceration showed a greater galectin-3 immunoreactivity in basal epithelia and stroma compared with controls. Immunofluorescence grading scores revealed increased colocalization of galectin-3 and CD147 in corneal ulcers at the epithelial-stromal junction and within fibroblasts. Quantitative analysis using the Manders' colocalization coefficient demonstrated significant overlap in corneas from patients with ulcerative keratitis (M1 = 0.29; M2 = 0.22) as opposed to control corneas (M1 = 0.01, P < 0.01; M2 = 0.02, P < 0.05). In these experiments, there was a significant positive correlation between the degree of galectin-3 and CD147 colocalization and the presence of gelatinolytic activity. Our results indicate that concomitant stimulation and colocalization of galectin-3 with CD147 are associated with increased gelatinolytic activity in the actively ulcerating human cornea and suggest a mechanism by which galectin-3 may contribute to the degradation of extracellular matrix proteins during ulceration.

  9. Autologous conjunctiva transplantation with stem cells on edge of cornea for recurrent pterygium

    Directory of Open Access Journals (Sweden)

    Yun Wang

    2013-10-01

    Full Text Available AIM: To observe the clinical effectiveness and practicality the autologous conjunctiva transplantation with stem cells on edge of cornea for recurrent pterygium.METHODS: Of the 53 recurrent pterygium patients(57 eyes, after all pathological tissues were removed, underwent the autologous conjunctiva transplantation with stem cells on edge of cornea which were locked above conjunctival transplantation of the operated eye.RESULTS: Postopretive follow-up was 1-12 months for all 57 eyes, of which 3 eyes(5%relapsed. The corneoscleral autolysis was occurred in one eye and surgery treatment was conducted. Corneal wounds were healing and transplantations survived well for the remaining 53 patients without obvious surgical marks. Cure rate was 93%.CONCLUSION: Autologous conjunctiva transplantation with stem cells on edge of cornea for recurrent pterygium can meet the aesthetic requirements of the some patients, with the advantages of obtaining material easily, faster wound healing, lower postoperative recurrence rate, meeting the aesthetic needs of some patients and improving postoperative results. Thus, it is an ideal surgery and is worthy of applying on primary hospital.

  10. Thermophysical properties of cement based composites and their changes after artificial ageing

    Science.gov (United States)

    Šín, Peter; Pavlendová, Gabriela; Lukovičová, Jozefa; Kopčok, Michal

    2017-07-01

    The usage of recycled plastic materials in concrete mix gained increased attention. The behaviour of such environmental friendly material is studied. In this paper an investigation of the thermophysical properties of cement based composites containing plastic waste particles with different percentage is presented. Measurements were carried out using pulse transient method before and after artificial ageing in climatic chamber BINDER MKF (E3).

  11. The Naïve Murine Cornea as a Model System to Identify Novel Endogenous Regulators of Lymphangiogenesis: TRAIL and rtPA.

    Science.gov (United States)

    Regenfuß, Birgit; Dreisow, Marie-Luise; Hos, Deniz; Masli, Sharmila; Bock, Felix; Cursiefen, Claus

    2015-06-01

    In the murine cornea, which is an established model for analyzing pathologic lymphatic vessel growth, phenotypic heterogeneity of the endogenous lymphatic vessels in the limbus of the cornea was previously described. In this study, the cornea of BALB/c, C57BL/6, and FVB mice with different limbal lymphangiogenic phenotypes was analyzed to identify novel candidates potentially influencing lymphatic vessel growth. Pathway specific expression analysis of the cornea was performed to identify novel candidate genes. Corneal protein expression of the respective candidates was analyzed by fluorescent immunohistochemistry. The effect of the candidates on proliferation of human dermal lymphatic endothelial cells (HDLECs) was analyzed by BrdU proliferation ELISA. Thirteen genes were differentially regulated in corneas of mouse strains with more endogenous limbal lymphatic vessels (high-lymphangiogenic) (C57BL/6) compared to mouse strains with less endogenous limbal lymphatic vessels (low-lymphangiogenic) (BALB/c, FVB). Two candidates, Tumor necrosis factor (ligand) superfamily member 10 (Tnfsf10/Trail) and Plasminogen activator, tissue (Plat/tPA) were expressed in the cornea of BALB/c and C57BL/6 mice on the protein level. In vitro, Trail and recombinant tPA inhibited the proliferation of human dermal lymphatic endothelial cells. Molecular analysis of the naive cornea in mouse strains with different limbal lymphatic phenotypes is a valuable model to identify novel endogenous regulators of lymphangiogenesis.

  12. Experience of Comamonas acidovorans keratitis with delayed onset and treatment response in immunocompromised cornea.

    Science.gov (United States)

    Lee, Sang Mok; Kim, Mee Kum; Lee, Jae Lim; Wee, Won Ryang; Lee, Jin Hak

    2008-03-01

    To report 2 cases of Comamonas acidovorans keratitis in immunocompromised cornea. A complete review of the medical records of the two cases of Comamonas acidovorans keratitis. We found some similarities in clinical courses of two cases. Both of them showed development of keratitis during the management with corticosteroids, delayed onset, slow response to antibiotics, and relatively less affected corneal epithelium. Comamonas acidovorans is known as a less virulent organism. However it can cause an indolent infection that responds slowly even to adequate antibiotics therapy in immunocompromised corneas.

  13. Intracellular Position of Centrioles and the Direction of Homeostatic Epithelial Cell Movements in the Mouse Cornea.

    Science.gov (United States)

    Silverman, Erika; Zhao, Jin; Merriam, John C; Nagasaki, Takayuki

    2017-02-01

    Corneal epithelial cells exhibit continuous centripetal movements at a rate of about 30 µm per day, but neither the driving force nor the mechanism that determines the direction of movements is known. To facilitate the investigation of homeostatic cell movement, we examined if the intracellular position of a centriole can be used as a directional marker of epithelial cell movements in the mouse cornea. A direction of cell movements was estimated in fixed specimens from a pattern of underlying subepithelial nerve fibers. Intracellular position of centrioles was determined by gamma-tubulin immunohistology and plotted in a narrow strip along the entire diameter of a cornea from limbus to limbus. When we determined the position of centrioles in the peripheral cornea where cell movements proceed generally along a radial path, about 55% of basal epithelial cells contained a centriole in the front half of a cell. However, in the central cornea where cells exhibit a spiral pattern of movements, centrioles were distributed randomly. These results suggest that centrioles tend to be positioned toward the direction of movement in corneal basal epithelial cells when they are moving centripetally at a steady rate.

  14. A comparison study of Riboflavin/UV-A and Rose-Bengal/Green light cross-linking of the rabbit corneas using optical coherence elastography

    Science.gov (United States)

    Li, Jiasong; Singh, Manmohan; Han, Zhaolong; Vantipalli, Srilatha; Liu, Chih-Hao; Wu, Chen; Raghunathan, Raksha; Kazemi, Tina; Twa, Michael D.; Larin, Kirill V.

    2016-03-01

    The biomechanical properties of the cornea are critical factors which determine its health and subsequent visual acuity. Keratoconus is a structural degeneration of the cornea which can diminish vision quality. Riboflavin/UV-A corneal collagen cross-linking (UV-CXL) is an emerging treatment that increases the stiffness of the cornea and improves its ability to resist further degeneration. While UV-CXL has shown great promise for effective therapy of the keratoconus, there are concerns associated with the UV irradiation, such as keratocyte cytotoxicity. Rose-bengal/green light corneal collagen cross-linking (RGX) has been proposed as an alternative to UV-CXL. Because of the high absorbance of the rose-bengal dye at green wavelengths, the treatment time is significantly shorter than with UV-CXL. Moreover, because green light is used in lieu of UV irradiation, there are no cytotoxic side-effects. In this study, noncontact optical coherence elastography (OCE) was used to compare the outcomes of UV-CXL and RGX treatment in rabbit cornea. Low-amplitude (micrometer scale) elastic waves were induced by a focused air-pulse loading system. The elastic wave propagation was then imaged by a phase-stabilized swept source OCE (PhS-SSOCE) system. The changes in the viscoelasticity of the corneas were quantified by a previously developed modified Rayleigh Lamb frequency model. The depth-resolved micro-scale phase-velocity distribution in the cornea was used to reveal the depth-wise heterogeneity before and after both cross-linking techniques. Our results show that UV-CXL and RGX increased the stiffness of the corneas by ~54% and ~5% while reducing the viscosity by ~42% and ~17%, respectively. The depth-wise phase velocities showed that UV-CXL affected the anterior ~1/3 of the corneas, while RGX only affected the anterior ~1/7 of the corneas.

  15. Effects of acetylcholine (ACh) and norepinephrine (NE) on phosphatidylinositol 4,5-bisphosphate (PIP2) turnover in rabbit cornea

    International Nuclear Information System (INIS)

    Akhtar, R.A.; Abdel-Latif, A.A.

    1986-01-01

    Muscarinic cholinergic and α 1 -adrenergic agonists provoke hydrolysis of PIP 2 into diacylglycerol (DG) and inositol trisphosphate (IP 3 ) in a wide variety of tissue. Recently, IP 3 has been shown to mobilize Ca 2+ from ER in several permeabilized tissue preparations. Although rabbit cornea is enriched in ACh and NE, the physiological function of these neurotransmitters is unclear. The present studies were initiated to determine the effects of cholinergic and adrenergic agonists on PIP 2 turnover in the cornea. Addition of ACh or NE (50 μM each) to the 32 P-labeled corneas for 10 min decreased the radioactivity in PIP 2 by 33 and 36%, and increased the radioactivity in phosphatidic acid by 72 and 52%, respectively. When the corneas were labeled with myo-[ 3 H]inositol, ACh and NE increased the accumulation of IP 3 by 92 and 48%, respectively. The effects of ACh and NE on phospholipid labeling and IP 3 accumulation were specifically inhibited by atropine (10 μM) and prazosin (10 μM), respectively. The data suggest the presence of muscarinic cholinergic and α 1 -adrenergic receptors in the rabbit cornea. Furthermore, activation of these receptors leads to cleavage of PIP 2 into DG and IP 3 which may function as second messengers in this tissue

  16. Taurine effect on cytogenetic lesions in the cornea of mice exposed to 9 Gev proton irradiation

    International Nuclear Information System (INIS)

    Vorozhtsova, S.V.; Yartsev, E.I.

    1989-01-01

    Possibilities of preventive measures and treatment of cytogenetic injuries in the mice cornea, subjected to proton irradiation at 9 Gev were studied. Taurine containing solution (TCS) was used as a radiomodifying agent. It is shown that TCS application enables to decrease aberrant mitoses level in cornea epithelium cells of mice. Antiactinic effect of the above agent is determined by its considerable action on mitotic delay

  17. A Model Approach for Finding Cleaning Solutions for Plasticized Poly(Vinyl Chloride) Surfaces of Collections Objects

    DEFF Research Database (Denmark)

    Sanz Landaluze, Jon; Egsgaard, Helge; Morales Munoz, Clara

    2014-01-01

    This study focused on developing a surface cleaning treatment for one type of commercially available plasticized poly(vinyl chloride). The effects of cleaning solutions on samples of plasticized poly(vinyl chloride) were examined by several methods. The sample surface, prior to and after artifici...

  18. Second harmonic generation microscopy of the living human cornea

    Science.gov (United States)

    Artal, Pablo; Ávila, Francisco; Bueno, Juan

    2018-02-01

    Second Harmonic Generation (SHG) microscopy provides high-resolution structural imaging of the corneal stroma without the need of labelling techniques. This powerful tool has never been applied to living human eyes so far. Here, we present a new compact SHG microscope specifically developed to image the structural organization of the corneal lamellae in living healthy human volunteers. The research prototype incorporates a long-working distance dry objective that allows non-contact three-dimensional SHG imaging of the cornea. Safety assessment and effectiveness of the system were firstly tested in ex-vivo fresh eyes. The maximum average power of the used illumination laser was 20 mW, more than 10 times below the maximum permissible exposure (according to ANSI Z136.1-2000). The instrument was successfully employed to obtain non-contact and non-invasive SHG of the living human eye within well-established light safety limits. This represents the first recording of in vivo SHG images of the human cornea using a compact multiphoton microscope. This might become an important tool in Ophthalmology for early diagnosis and tracking ocular pathologies.

  19. Plastics in Our Environment: A Jigsaw Learning Activity

    Science.gov (United States)

    Hampton, Elaine; Wallace, Mary Ann; Lee, Wen-Yee

    2009-01-01

    In this lesson, a ready-to-teach cooperative reading activity, students learn about the effects of plastics in our environment, specifically that certain petrochemicals act as artificial estrogens and impact hormonal activities. Much of the content in this lesson was synthesized from recent medical research about the impact of xenoestrogens and…

  20. Quantifying the effects of UV-A/riboflavin crosslinking on the elastic anisotropy and hysteresis of the porcine cornea by noncontact optical coherence elastography

    Science.gov (United States)

    Singh, Manmohan; Li, Jiasong; Raghunathan, Raksha; Han, Zhaolong; Nair, Achuth; Liu, Chih-Hao; Aglyamov, Salavat R.; Twa, Michael D.; Larin, Kirill V.

    2017-02-01

    The collagen fibril orientation of the cornea can provide critical information about cornea tissue health because diseases such as keratoconus and therapeutic interventions such as UV-A/riboflavin corneal collagen crosslinking (CXL) can alter the ultrastructural arrangement of collagen fibrils. Here, we quantify the elastic anisotropy and hysteresis of in situ porcine corneas as a function of intraocular pressure (IOP) with noncontact optical coherence elastography. Moreover, the effects of UV-A riboflavin corneal collagen crosslinking on the elastic anisotropy and hysteresis were evaluated. The propagation of an air-pulse induced elastic wave was imaged at stepped meridional angles by a home built phasestabilized swept source OCE system. The stiffness of the cornea was translated from the velocity of the wave, and the elastic anisotropy was quantified by modifying the planar anisotropy coefficient. As the IOP increased, the stiffness of the corneas increased from 18 kPa at 15 mmHg IOP to 120 kPa at 30 mmHg IOP. While there was a measureable hysteresis, it was not significant. After CXL, the Young's modulus of the corneas significantly increased from 18 kPa to 44 kPa at 15 mmHg IOP. The mechanical anisotropy also increased significantly from 10 a.u. in the untreated corneas to 23 a.u. in the CXL treated corneas, 15 mmHg IOP. However, CXL did not change the elastic anisotropic orientation, and the mechanical anisotropic hysteresis was not significant after CXL.

  1. Expression profiles of aquaporins in rat conjunctiva, cornea, lacrimal gland and Meibomian gland.

    Science.gov (United States)

    Yu, Dongfang; Thelin, William R; Randell, Scott H; Boucher, Richard C

    2012-10-01

    The aim of the study was to elucidate aquaporin (AQP) family member mRNA expression and protein expression/localization in the rat lacrimal functional unit. The mRNA expression of all rat AQPs (AQP0-9, 11-12) in palpebral, fornical, and bulbar conjunctiva, cornea, lacrimal gland, and Meibomian gland was measured by Reverse Transcriptase-Polymerase Chain Reaction (RT-PCR) and real time RT-PCR. Antibodies against AQP1, 3, 4, 5, 9, and 11 were used in Western blotting and immunohistochemistry to determine protein expression and distribution. Our study demonstrated characteristic AQP expression profiles in rat ocular tissues. AQP1, 3, 4, 5, 8, 9, 11, and 12 mRNA were detected in conjunctiva. AQP0, 1, 2, 3, 4, 5, 6, 11, and 12 mRNA were expressed in cornea. AQP0, 1, 2, 3, 4, 5, 7, 8, and 11 mRNA were detected in lacrimal gland. AQP1, 3, 4, 5, 7, 8, 9, 11, and 12 mRNA were identified in Meibomian gland. By Western blot, AQP1, 3, 5, and 11 were detected in conjunctiva; AQP1, 3, 5, and 11 were identified in cornea; AQP1, 3, 4, 5, and 11 were detected in lacrimal gland; and AQP1, 3, 4, 5, 9, and 11 were present in Meibomian gland. Immunohistochemistry localized AQPs to distinct sites in the various tissues. This study rigorously analyzed AQPs expression and localization in rat conjunctiva, cornea, lacrimal gland, and Meibomian gland tissues. Our findings provide a comprehensive platform for further investigation into the physiological or pathophysiological relevance of AQPs in ocular surface. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Fumigation treatment of Four Yellow Qing Ling Water with artificial tears for dry eyes

    Directory of Open Access Journals (Sweden)

    Yan-Yan Chen

    2018-04-01

    Full Text Available AIM: To observe the clinical efficacy of fumigation treatment of traditional Chinese medicine(Four Yellow Qing Ling Waterfor dry eye, and to provide the reference for clinical treatment of dry eye. METHODS: Totally 82 patients(164 eyeswere randomly divided into two groups from June 2016 to December 2016 in Ophthalmology Department of our hospital. The patients in control group were given artificial tears; the patients in the observation group were given artificial tears and fumigation treatment of traditional Chinese(Four Yellow Qing Ling Wateronce a day. After treatment for 14d, the Schirmer Ⅰ test(SⅠt, break-up time(BUT, cornea fluorescein staining(FLand clinical efficacy of two groups were compared. RESULTS: The efficiency rate of observation group was significantly better than the control group(87.8% vs 70.7%, Pvs 6.38±2.52mm/5min, Pvs 6.35±2.29s, Pvs 1.26±0.84, PCONCLUSION: The fumigation treatment of traditional Chinese medicine(Four Yellow Qing Ling Watercombined with artificial tears for dry eyes can improve the clinical symptoms of dry eye syndrome.

  3. Study of the protective properties of paraaminobenzoic acid for cornea of adult rats under X-radiation

    International Nuclear Information System (INIS)

    Stroeva, O.G.; Panova, I.G.; Mel'nikova, I.I.

    1997-01-01

    To test the efficiency of para-aminobenzoic acid (PABA) as a radioprotector for mammal tissues the protective properties of PABA for cornea of adult rats-males exposed to single whole-body irradiation were studied. X-irradiation was performed using RUM-17 facility at the dose of 5 Gy (dose rate is of 0.886 Gy/min). Results obtained prove reliably radioprotective and therapeutic effect of PABA on the cornea cells [ru

  4. The filtering, clear-cornea diathermal keratostomy: a minor Danish multicenter study

    DEFF Research Database (Denmark)

    Kessing, S.V.; Nissen, O.I.; Thygesen, J.

    2008-01-01

    PURPOSE: Is the new micropenetrating, clear-cornea procedure, intrastromal diathermal keratostomy (IDK), an alternative to the intricate "modern trabeculectomy"? METHODS: Prospective multicenter study. Four surgeons from 4 Danish eye departments attended an IDK course and subsequently decided whe...

  5. Damage Threshold of In Vivo Rabbit Cornea by 2 micron Laser Irradiation

    National Research Council Canada - National Science Library

    Chen, Bo; Oliver, Jeffery; Dutta, Soumak; Rylander, III, Grady H; Thomsen, Sharon L; Welch, Ashley J

    2007-01-01

    To support refinement of the Maximum Permissible Exposure (MPE) safety limits, a series of experiments were conducted in vivo on Dutch Belted rabbit corneas to determine corneal minimum visible lesion thresholds...

  6. Dexamethasone Drug Eluting Nanowafers Control Inflammation in Alkali-Burned Corneas Associated With Dry Eye

    Science.gov (United States)

    Bian, Fang; Shin, Crystal S.; Wang, Changjun; Pflugfelder, Stephen C.; Acharya, Ghanashyam; De Paiva, Cintia S.

    2016-01-01

    Purpose To evaluate the efficacy of a controlled release dexamethasone delivery system for suppressing inflammation in an ocular burn + desiccating stress (OB+DS) model. Methods Nanowafers (NW) loaded with Dexamethasone (Dex, 10 μg) or vehicles (2.5% Methylcellulose; MC) were fabricated using hydrogel template strategy. C57BL/6 mice were subjected to unilateral alkali ocular burn with concomitant desiccating stress for 2 or 5 days and topically treated either with 2 μL of 0.1% Dex or vehicle four times per day and compared with mice that had MC-NW or Dex-NW placed on their corneas. Clinical parameters were evaluated daily. Mice were euthanized after 2 or 5 days. Quantitative PCR evaluated the expression of inflammatory cytokines IL-1β and IL-6 and matrix metalloproteinases (MMP) in whole cornea lysates. Myeloperoxidase activity (MPO) was measured using a commercial kit in cornea lysates. Results Both Dex drop and Dex-NW groups had significantly lower corneal opacity scores compared with their vehicles. Both Dex drops and Dex-NW significantly decreased expression of IL-1β, IL-6, and MMP-9 RNA transcripts compared with vehicle drops or wafers 2 and 5 days after the initial lesion. A significant lower number of neutrophils was found in both Dex treatment groups and this was accompanied by decreased MPO activity compared with vehicle controls. Conclusions Dex-NW has efficacy equal to Dex drops in preserving corneal clarity and decreasing expression of MMPs and inflammatory cytokines of the corneas of mice subjected to an OB+DS model. PMID:27327581

  7. Femtosecond laser cutting of human corneas for the subbasal nerve plexus evaluation.

    Science.gov (United States)

    Kowtharapu, B S; Marfurt, C; Hovakimyan, M; Will, F; Richter, H; Wree, A; Stachs, O; Guthoff, R F

    2017-01-01

    Assessment of various morphological parameters of the corneal subbasal nerve plexus is a valuable method of documenting the structural and presumably functional integrity of the corneal innervation in health and disease. The aim of this work is to establish a rapid, reliable and reproducible method for visualization of the human corneal SBP using femtosecond laser cut corneal tissue sections. Trephined healthy corneal buttons were fixed and processed using TissueSurgeon-a femtosecond laser based microtome, to obtain thick tissue sections of the corneal epithelium and anterior stroma cut parallel to the ocular surface within approximately 15 min. A near infrared femtosecond laser was focused on to the cornea approximately 70-90 μm from the anterior surface to induce material separation using TissueSurgeon. The obtained corneal sections were stained following standard immunohistochemical procedures with anti-neuronal β-III tubulin antibody for visualization of the corneal nerves. Sections that contained the epithelium and approximately 20-30 μm of anterior stroma yielded excellent visualisation of the SBP with minimal optical interference from underlying stromal nerves. In conclusion, the results of this study have demonstrated that femtosecond laser cutting of the human cornea offers greater speed, ease and reliability than standard tissue preparation methods for obtaining high quality thick sections of the anterior cornea cut parallel to the ocular surface. © 2016 The Authors Journal of Microscopy © 2016 Royal Microscopical Society.

  8. Application of Soft Computing for the Prediction of Warpage of Plastic Injection

    Directory of Open Access Journals (Sweden)

    Vijaya Kumar Reddy

    2009-01-01

    Full Text Available This paper deals with the development of accurate warpage prediction model for plastic injection molded parts using softcomputing tools namely, artificial neural networks and support vector machines. For training, validating and testing of thewarpage model, a number of MoldFlow (FE analyses have been carried out using Taguchi’s orthogonal array in the designof experimental technique by considering the process parameters such as mold temperature, melt temperature, packing pressure,packing time and cooling time. The warpage values were found by analyses which were done by MoldFlow PlasticInsight (MPI 5.0 software. The artificial neural network model and support vector machine regression model have beendeveloped using conjugate gradient learning algorithm and ANOVA kernel function respectively. The adequacy of the developedmodels is verified by using coefficient of determination. To judge the ability and efficiency of the models to predictthe warpage values absolute relative error has been used. The finite element results show, artificial neural network modelpredicts with high accuracy compared with support vector machine model.

  9. Specific demographic factors could predict deceased potential cornea donors: A retrospective study from Beijing Tongren Hospital Eye Bank.

    Science.gov (United States)

    Liu, Yang; Zhang, Yingnan; Zhang, Jing; Yu, Jin; Liang, Qingfeng; Pan, Zhiqiang

    2017-12-01

    Compared with evident cornea donors (ECDs), deceased potential cornea donors (DPCDs) have no obvious donor identifications to reference, which causes many eligible cornea tissues to be wasted. The demographic characteristics of DPCDs might be different from those of ECDs owing to the following different features: donation consent provided by relatives and willingness to donate before death. Thus, the aim of this study is to reveal the demographic characteristics of DPCDs by comparing DPCDs and ECDs.The demographic factors of 138 donors (both DPCDs and ECDs) were collected from the Beijing Tongren Hospital Eye Bank database and analyzed. To differentiate DPCDs from ECDs using the above-mentioned features, we interviewed the relatives of the donors by telephone. The relatives' attitudes toward cornea donation and their suggestions for our donation service were also acquired during the interview. Two logistic regressions were performed to reveal the demographic factors influencing the 2 features and indicate DPCDs.The donors had certain demographic characteristics (elderly, secondary, or tertiary education level, central district resident), and the most frequent cause of death for the donors was a malignant tumor (n = 56, 43.1%). All the relatives had positive attitudes toward cornea donations, and they hoped to increase publicity efforts to encourage more people to donate and establish more convenient and efficient access for cornea donation. In univariate regressions, age (P = .004, >50 years: odds ratio [OR] = 6.89, 95% confidence interval [CI]: 1.82-26.05), marital status (P = .043, divorced: OR = 9.00,95% CI: 1.33-60.80) significantly influenced relative consent, whereas age (P = .001, >50 years: OR = 15.00, 95% CI: 3.00-74.98), and family address (P = .001, central district: OR = 1) were significant factors influencing the willingness to donate before death. In multivariate regression, age (P = .021, >50 years: OR = 8

  10. Infrared irradiation alters the expression of matrix metalloproteinases and glycosaminoglycans in the cornea and crystalline lens.

    Science.gov (United States)

    Dadoukis, Panagiotis; Klagas, Ioannis; Komnenou, Anastasia; Karakiulakis, George; Karoutis, Athanasios; Karampatakis, Vassilios; Papakonstantinou, Eleni

    2013-08-01

    Prolonged exposure to infrared (IR) radiation is associated with different types of damage to cornea and lens. The aim of our study was to investigate the effect of acute and chronic exposure to IR radiation on the activity of matrix metalloproteinase-2 (MMP-2) and MMP-9 and on the expression of glycosaminoglycans (GAG) in the rabbit cornea and crystalline lens. New Zealand rabbits were subjected to IR radiation for 4 months (chronic exposure to IR) or to normal light (control group). In experiments regarding acute exposure, animals were subjected to IR radiation or normal light for 12 h, in the presence of 0.1% diclofenac sodium (eye drops instilled in the right eye of animals) or saline (instilled in the left eye of animals). The cornea and lens were dissected away and homogenized. The activity of MMP-2 and MMP-9 was assayed by gelatine zymography. Total GAG were isolated from tissue specimens after lipid extraction and extensive digestion with pronase and DNase and characterized by treatment with GAG-degrading enzymes, followed by electrophoresis on cellulose acetate membranes. Acute or chronic exposure to IR radiation induced the activity of MMP-2 in cornea and lens, whereas only acute IR radiation increased the content of heparan sulphate in crystalline lens. Local administration of diclofenac sodium did not prevent the above effects of acute IR radiation. The detrimental effects of excessive or prolonged exposure of the eyes to IR radiation are associated with induced activity of MMP-2 in cornea and lens and alterations in the content of heparan sulphate in lens. Thus, MMP and GAG may offer alternative targets for pharmacological intervention to confront ocular damages associated with IR radiation.

  11. Plasticity between Epithelial and Mesenchymal States Unlinks EMT from Metastasis-Enhancing Stem Cell Capacity

    Directory of Open Access Journals (Sweden)

    Evelyne Beerling

    2016-03-01

    Full Text Available Forced overexpression and/or downregulation of proteins regulating epithelial-to-mesenchymal transition (EMT has been reported to alter metastasis by changing migration and stem cell capacity of tumor cells. However, these manipulations artificially keep cells in fixed states, while in vivo cells may adapt transient and reversible states. Here, we have tested the existence and role of epithelial-mesenchymal plasticity in metastasis of mammary tumors without artificially modifying EMT regulators. In these tumors, we found by intravital microscopy that the motile tumor cells have undergone EMT, while their epithelial counterparts were not migratory. Moreover, we found that epithelial-mesenchymal plasticity renders any EMT-induced stemness differences, as reported previously, irrelevant for metastatic outgrowth, because mesenchymal cells that arrive at secondary sites convert to the epithelial state within one or two divisions, thereby obtaining the same stem cell potential as their arrived epithelial counterparts. We conclude that epithelial-mesenchymal plasticity supports migration but additionally eliminates stemness-enhanced metastatic outgrowth differences.

  12. [Biological availability of ophthalmic drugs. 1. Increasing drug permeability in the cornea].

    Science.gov (United States)

    Masteiková, R; Chalupová, Z; Savickiene, N

    2004-03-01

    Most eye diseases are treated by topical administration of ophthalmic preparations. Low ophthalmic bioavailability is due to a number of physiological and physicochemical factors. The main obstacle to the penetration of active ingredients to the eye is the layered character of the cornea. Formulation of ophthalmic preparations enabling easier penetration of this biological barrier thus ranks among the most effective ways of improving bioavailability. Penetrability of the cornea can be increased by the following methods: a) adjustment of the actual acidity in such a way that pH of the preparation makes it possible to produce the optimal portion of non-ionized particles; b) incorporation of absorption enhancers (non-ionic tensides, salts of bile acids, some antimicrobial substances, EDTA, cyclodextrins, etc.) into the composition of the preparation, and c) production of prodrugs or ionic pairs.

  13. Poliuretana derivada de óleos vegetais exposta ao intemperismo artificial Polyurethane derived from vegetal oil exposed to artificial weathering

    Directory of Open Access Journals (Sweden)

    Alessandra E. F. S. Almeida

    2006-01-01

    Full Text Available Foram obtidas as propriedades mecânicas e viscoelásticas da poliuretana derivada do óleo de mamona após sua exposição ao intemperismo artificial, a fim de avaliar a aplicabilidade deste material como revestimento polimérico para substratos de concreto na Construção Civil. Os procedimentos experimentais foram realizados em conformidade com a ASTM G 53 for "Operating Light and Water Exposure Apparatus (Fluorescent UV - Condensation Type for Exposure of Nonmetallic Materials"[1]. O ensaio para a caracterização mecânica dos corpos-de-prova após exposição ao intemperismo artificial foi realizado conforme a norma ASTM D 638M-96 "Standard Test Method for Tensile Properties of Plastics (Metric"[2]. Foi empregado o método de análise dinâmico-mecânica para a obtenção das propriedades viscoelásticas da poliuretana vegetal. Os resultados mostraram que a exposição ao intemperismo artificial não ocasionou mudanças significativas nas propriedades do revestimento polimérico para o tempo de exposição estudado.The mechanical and viscoelastic properties of polyurethane derived from castor oil were obtained after being exposed to artificial weathering with the purpose of evaluating their applicability as polymeric coatings on concrete substrate for Civil Construction. The procedures followed the ASTM G53 for "Operating Light and Water Exposure Apparatus (Fluorescent UV - Condensation Type for Exposure of Nonmetallic Materials"[1]. Mechanical properties were obtained by means of the ASTM D 638M-96 "Standard Test Method for Tensile Properties of Plastics (Metric"[2]. Furthermore, a Dynamic Mechanical Analysis (DMA was carried out in order to study the viscoelastic properties of polyurethane. The results showed that the properties were altered slightly considering the time studied.

  14. Corneal Collagen Cross-Linking with Hypoosmolar Riboflavin Solution in Keratoconic Corneas

    Directory of Open Access Journals (Sweden)

    Shaofeng Gu

    2014-01-01

    Full Text Available Purpose. To report the 12-month outcomes of corneal collagen cross-linking (CXL with a hypoosmolar riboflavin and ultraviolet-A (UVA irradiation in thin corneas. Methods. Eight eyes underwent CXL using a hypoosmolar riboflavin solution after epithelial removal. The corrected distance visual acuity (CDVA, manifest refraction, the mean thinnest corneal thickness (MTCT, and the endothelial cell density (ECD were evaluated before and 6 and 12 months after CXL. Results. The MTCT was 413.9 ± 12.4 μm before treatment and reduced to 381.1 ± 7.3 μm after the removal of the epithelium. After CXL, the thickness decreased to 410.3 ± 14.5 μm at the last follow-up. Before treatment, the mean K-value of the apex of the keratoconus corneas was 58.7 ± 3.5 diopters and slightly decreased (57.7 ± 4.9 diopters at 12 months. The mean CDVA was 0.54 ± 0.23 logarithm of the minimal angle of resolution before treatment and increased to 0.51 ± 0.21 logarithm at the last follow-up. The ECD was 2731.4 ± 191.8 cells/mm2 before treatment and was 2733.4 ± 222.6 cells/mm2 at 12 months after treatment. Conclusions. CXL with a hypoosmolar riboflavin in thin corneas seems to be a promising method for keratoconic eyes with the mean thinnest corneal thickness less than 400 μm without epithelium.

  15. Novel micelle carriers for cyclosporin A topical ocular delivery: in vivo cornea penetration, ocular distribution and efficacy studies.

    Science.gov (United States)

    Di Tommaso, Claudia; Bourges, Jean-Louis; Valamanesh, Fatemeh; Trubitsyn, Gregory; Torriglia, Alicia; Jeanny, Jean-Claude; Behar-Cohen, Francine; Gurny, Robert; Möller, Michael

    2012-06-01

    Cornea transplantation is one of the most performed graft procedures worldwide with an impressive success rate of 90%. However, for "high-risk" patients with particular ocular diseases in addition to the required surgery, the success rate is drastically reduced to 50%. In these cases, cyclosporin A (CsA) is frequently used to prevent the cornea rejection by a systemic treatment with possible systemic side effects for the patients. To overcome these problems, it is a challenge to prepare well-tolerated topical CsA formulations. Normally high amounts of oils or surfactants are needed for the solubilization of the very hydrophobic CsA. Furthermore, it is in general difficult to obtain ocular therapeutic drug levels with topical instillations due to the corneal barriers that efficiently protect the intraocular structures from foreign substances thus also from drugs. The aim of this study was to investigate in vivo the effects of a novel CsA topical aqueous formulation. This formulation was based on nanosized polymeric micelles as drug carriers. An established rat model for the prevention of cornea graft rejection after a keratoplasty procedure was used. After instillation of the novel formulation with fluorescent labeled micelles, confocal analysis of flat-mounted corneas clearly showed that the nanosized carriers were able to penetrate into all corneal layers. The efficacy of a 0.5% CsA micelle formulation was tested and compared to a physiological saline solution and to a systemic administration of CsA. In our studies, the topical CsA treatment was carried out for 14 days, and the three parameters (a) cornea transparency, (b) edema, and (c) neovascularization were evaluated by clinical observation and scoring. Compared to the control group, the treated group showed a significant higher cornea transparency and significant lower edema after 7 and 13 days of the surgery. At the end point of the study, the neovascularization was reduced by 50% in the CsA-micelle treated

  16. In vivo 3D measurement of moxifloxacin and gatifloxacin distributions in the mouse cornea using multiphoton microscopy

    OpenAIRE

    Lee, Seunghun; Lee, Jun Ho; Park, Jin Hyoung; Yoon, Yeoreum; Chung, Wan Kyun; Tchah, Hungwon; Kim, Myoung Joon; Kim, Ki Hean

    2016-01-01

    Moxifloxacin and gatifloxacin are fourth-generation fluoroquinolone antibiotics used in the clinic to prevent or treat ocular infections. Their pharmacokinetics in the cornea is usually measured from extracted ocular fluids or tissues, and in vivo direct measurement is difficult. In this study multiphoton microscopy (MPM), which is a 3D optical microscopic technique based on multiphoton fluorescence, was applied to the measurement of moxifloxacin and gatifloxacin distribution in the cornea. I...

  17. In vivo imaging through the entire thickness of human cornea by full-field optical coherence tomography

    Science.gov (United States)

    Mazlin, Viacheslav; Xiao, Peng; Dalimier, Eugénie; Grieve, Kate; Irsch, Kristina; Sahel, José; Fink, Mathias; Boccara, Claude

    2018-02-01

    Despite obvious improvements in visualization of the in vivo cornea through the faster imaging speeds and higher axial resolutions, cellular imaging stays unresolvable task for OCT, as en face viewing with a high lateral resolution is required. The latter is possible with FFOCT, a method that relies on a camera, moderate numerical aperture (NA) objectives and an incoherent light source to provide en face images with a micrometer-level resolution. Recently, we for the first time demonstrated the ability of FFOCT to capture images from the in vivo human cornea1. In the current paper we present an extensive study of appearance of healthy in vivo human corneas under FFOCT examination. En face corneal images with a micrometer-level resolution were obtained from the three healthy subjects. For each subject it was possible to acquire images through the entire corneal depth and visualize the epithelium structures, Bowman's layer, sub-basal nerve plexus (SNP) fibers, anterior, middle and posterior stroma, endothelial cells with nuclei. Dimensions and densities of the structures visible with FFOCT, are in agreement with those seen by other cornea imaging methods. Cellular-level details in the images obtained together with the relatively large field-of-view (FOV) and contactless way of imaging make this device a promising candidate for becoming a new tool in ophthalmological diagnostics.

  18. A human hemi-cornea model for eye irritation testing: quality control of production, reliability and predictive capacity.

    Science.gov (United States)

    Engelke, M; Zorn-Kruppa, M; Gabel, D; Reisinger, K; Rusche, B; Mewes, K R

    2013-02-01

    We have developed a 3-dimensional human hemi-cornea which comprises an immortalized epithelial cell line and keratocytes embedded in a collagen stroma. In the present study, we have used MTT reduction of the whole tissue to clarify whether the production of this complex 3-D-model is transferable into other laboratories and whether these tissues can be constructed reproducibly. Our results demonstrate the reproducible production of the hemi-cornea model according to standard operation procedures using 15 independent batches of reconstructed hemi-cornea models in two independent laboratories each. Furthermore, the hemi-cornea tissues have been treated with 20 chemicals of different eye-irritating potential under blind conditions to assess the performance and limitations of our test system comparing three different prediction models. The most suitable prediction model revealed an overall in vitro-in vivo concordance of 80% and 70% in the participating laboratories, respectively, and an inter-laboratory concordance of 80%. Sensitivity of the test was 77% and specificity was between 57% and 86% to discriminate classified from non-classified chemicals. We conclude that additional physiologically relevant endpoints in both epithelium and stroma have to be developed for the reliable prediction of all GHS classes of eye irritation in one stand alone test system. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. The healing of alkali-injured cornea is stimulated by a novel matrix regenerating agent (RGTA, CACICOL20): a biopolymer mimicking heparan sulfates reducing proteolytic, oxidative and nitrosative damage.

    Science.gov (United States)

    Cejkova, Jitka; Olmiere, Celine; Cejka, Cestmir; Trosan, Peter; Holan, Vladimir

    2014-04-01

    The efficacy of a chemically modified dextran - heparan sulfate mimicking regenerating agent (RGTA) on the healing of the rabbit cornea injured with alkali was examined. The eyes were injured with 0.15 N NaOH applied on the cornea or with 1.0 N NaOH using a 8 mm diameter filter paper disk. Then RGTA or placebo was applied on the cornea. In the last group of rabbits, corneas injured with the high alkali concentration were left without any treatment for four weeks; subsequently, the corneas were treated with RGTA or placebo. The central corneal thickness was measured using a pachymeter. The corneas were examined morphologically, immunohistochemically and for real time-PCR. Compared to control (unaffected) corneas, following the application of low alkali concentration the expression of urokinase-type plasminogen activator, metalloproteinase 9, nitric oxide synthase and xanthine oxidase was increased in the injured corneal epithelium of placebo-treated eyes, whereas the expression of antioxidant enzymes was reduced. Nitrotyrosine and malondialdehyde stainings appeared in the corneal epithelium. RGTA application suppressed the antioxidant/prooxidant imbalance and reduced the expression of the above-mentioned immunohistochemical markers. The corneal thickness increased after alkali injury, decreased during corneal healing after RGTA treatment faster than after placebo application. Following the injury with the high alkali concentration, corneal inflammation and neovascularization were highly pronounced in placebo-treated corneas, whereas in RGTA-treated corneas they were significantly supressed. When RGTA or placebo application was started later after alkali injury and corneas were ulcerated, subsequent RGTA treatment healed the majority of them. In conclusion, RGTA facilitates the healing of injured corneas via a reduction of proteolytic, oxidative and nitrosative damage.

  20. Artificial light and nocturnal activity in gammarids

    Directory of Open Access Journals (Sweden)

    Elizabeth K. Perkin

    2014-03-01

    Full Text Available Artificial light is gaining attention as a potential stressor to aquatic ecosystems. Artificial lights located near streams increase light levels experienced by stream invertebrates and we hypothesized light would depress night drift rates. We also hypothesized that the effect of light on drift rates would decrease over time as the invertebrates acclimated to the new light level over the course of one month’s exposure. These hypotheses were tested by placing Gammarus spp. in eight, 75 m × 1 m artificial flumes. One flume was exposed to strong (416 lx artificial light at night. This strong light created a gradient between 4.19 and 0.04 lx over the neighboring six artificial flumes, while a control flume was completely covered with black plastic at night. Night-time light measurements taken in the Berlin area confirm that half the flumes were at light levels experienced by urban aquatic invertebrates. Surprisingly, no light treatment affected gammarid drift rates. In contrast, physical activity measurements of in situ individually caged G. roeseli showed they increased short-term activity levels in nights of complete darkness and decreased activity levels in brightly lit flumes. Both nocturnal and diurnal drift increased, and day drift rates were unexpectadly higher than nocturnal drift.

  1. Donor cornea procurement: six-year review of the role of the eye bank in South Australia.

    Science.gov (United States)

    Williams, K A; White, M A; Badenoch, P R; Wedding, T R; Alfrich, S J; Sawyer, M A; Noack, L M; Johnstone, E W; Zilm, G; Coster, D J

    1990-02-01

    The Lions Eye Bank of South Australia was established six years ago and has collected corneas from 790 donors. The consent rate is currently 82% of requests made. Two-thirds of donors have been male, with mean donor age/year varying from 54 to 64 years (range two to 93 years). Cardiovascular and respiratory diseases, trauma and haemorrhage account for 80% of all donor deaths. Mean death to enucleation time is five hours. Corneas assessed as being of excellent or very good quality are released preferentially from the bank; those with central endothelial cell counts of less than 1500 cells/mm2 are discarded. Fewer than 1% of donors have returned a positive result for HIV or hepatitis B. Of the 1580 corneas collected by the bank, 863 (55%) have been used for transplantation with a primary non-function rate of 0.46%. The evolving policies, logistics of operation and methodologies employed by the bank are described in detail.

  2. Estudo comparativo entre duas plataformas para realização de Lasik personalizado para correção de miopia e astigmatismo: Alcon CustomCornea® versus Bausch & Lomb Zyoptix® Wavefront-Guided Lasik for low to moderate myopia: CustomCornea® versus Zyoptix®

    Directory of Open Access Journals (Sweden)

    Telma Pereira Barreiro

    2009-08-01

    Full Text Available OBJETIVO: Comparar os resultados obtidos após o Lasik personalizado utilizando duas plataformas diferentes. MÉTODOS: Estudo prospectivo, randomizado com 50 pacientes míopes submetidos a cirurgia refrativa em ambos os olhos. Foram selecionados para o estudo, pacientes com equivalente esférico semelhante entre os olhos. Todos foram submetidos a Lasik bilateral e simultâneo, sendo que um olho foi operado pela plataforma CustomCornea® e o outro pela Zyoptix®. Acuidade visual sem e com correção, refração dinâmica e estática, medida das aberrações oculares, teste de sensibilidade ao contraste foram realizados no período pré-operatório e pós-operatório de 1, 3 e 6 meses. RESULTADOS: No período pré-operatório a média do equivalente esférico era de -3,29 ± 1,56 D no grupo CustomCornea® e de -3,22 ± 1,50 D no Zyoptix® (p=0,267. No sexto mês de pós-operatório, a média do equivalente esférico no grupo CustomCornea® era de -0,077 ± 0,23 D e -0,282 ± 0,30 D no Zyoptix® (p 20/20 foi alcançada em 86% dos olhos no grupo CustomCornea® e 70% no grupo Zyoptix® (p=0,094. Nenhum paciente perdeu duas ou mais linhas da melhor acuidade visual corrigida. Cem por cento dos olhos CustomCornea® e 88% dos Zyoptix® ficaram entre ± 0,50 D da emetropia (p=0,014*. Melhora da sensibilidade ao contraste em todas as frequências espaciais testadas foi observada em ambos os grupos. A aberração esférica apresentou aumento em ambos os grupos, porém este foi estatisticamente maior na plataforma Zyoptix® (pPURPOSE: To compare the visual and clinical outcomes of Wavefront-guided laser in situ keratomileusis (Lasik with Alcon CustomCornea® and Zyoptix® systems. METHODS: A prospective, randomized, masked and bilateral study was conducted. Fifty patients with preoperative spherical equivalent ranging from -1.00 to -6.50 D were enrolled for customized ablation in both eyes. All of them were submitted to Lasik CustomCornea® treatment in one

  3. Adjunctive cryotherapy for pigmentary keratitis in dogs: a study of 16 corneas.

    Science.gov (United States)

    Azoulay, Thierry

    2014-07-01

    To assess whether soft cryotherapy (dimethylether, isobutene, and propane) can remove pigmentation of the cornea that has accumulated under different conditions when conventional therapy has been unsuccessful. Nine dogs with unilateral or bilateral corneal pigmentation (16 eyes) were included based on progressive corneal pigmentation that was unresponsive to long-term etiological treatment. The dogs had keratoconjunctivitis sicca or chronic superficial keratitis. A cryogen of 95% dimethylether, 3% isobutane, and 2% propane was applied to the pigmented areas of each cornea under anesthesia. Initial corneal pigmentation and changes were documented over the entire study period using a grading scheme and clinical photographs. Most of the pigment deposits were gone by 5-15 days after cryosurgery. Postoperatively, the dogs showed some corneal edema and corneo-conjunctival inflammation, and three dogs had superficial corneal ulcers; these symptoms had resolved by 1 month after the procedure. Follow-up for more than 90 days was available in five dogs (nine corneas), and we observed total or partial repigmentation when the underlying disease was not controlled. A new cryotherapy procedure was successfully performed in two of these dogs. Given the sensitivity to cold of melanocytes, cryotherapy is a viable adjunctive treatment for refractory severe corneal pigmentation. Etiological treatment remains necessary to prevent pigmentation from rapidly reappearing. Only a few dogs were followed for more than 90 days; further study is necessary to evaluate the long-term safety and efficacy of soft cryotherapy. © 2013 American College of Veterinary Ophthalmologists.

  4. Chitosan-functionalized silk fibroin 3D scaffold for keratocyte culture.

    Science.gov (United States)

    Guan, Linan; Tian, Pei; Ge, Hongyan; Tang, Xianling; Zhang, Hong; Du, Lingling; Liu, Ping

    2013-10-01

    The goal of this study was to evaluate the potential suitability of an artificial membrane composed of silk fibroin (SF) functionalized by different ratios of chitosan (CS) as a substrate for the stroma of the cornea. Keratocytes were cultured on translucent membranes made of SF and CS with different ratios. The biophysical properties of the silk fibroin and chitosan (SF/CS) membrane were examined. The SF/CS showed tensile strengths that increased as the CS concentration increased, but the physical and mechanical properties of chitosan-functionalized silk fibroin scaffolds weakened significantly compared with those of native corneas. The resulting cell scaffolds were evaluated using western blot in addition to light and electron microscopy. The cell attachment and proliferation on the scaffold were similar to those on a plastic plate. Keratocytes cultured in serum on SF/CS exhibited stellate morphology along with a marked increase in the expression of keratocan compared with identical cultures on tissue culture plastics. The biocompatibility was tested by transplanting the acellular membrane into rabbit corneal stromal pockets. There was no inflammatory complication detected at any time point on the macroscopic level. Taken together, these results indicate that SF/CS holds promise as a substrate for corneal reconstruction.

  5. Colemanite: a fire retardant candidate for wood plastic composites

    Science.gov (United States)

    Evren Terzi; Saip Nami Kartal; Sabriye Piskin; Nicole Stark; Aysel Kanturk Figen; Robert H. White

    2018-01-01

    The use of raw boron minerals (i.e. tincalconite, colemanite, and ulexite) was evaluated to increase the fire performance of wood plastic composites (WPCs) in comparison with commercially available fire retardants (FRs). Cone calorimetry and limited oxygen index tests were performed to evaluate the fire properties of WPC specimens. Artificial weathering and 3-point...

  6. Determination of natamycin in rabbit cornea by high-performance liquid chromatography-tandem mass spectrometry with protective soaking extraction technology.

    Science.gov (United States)

    Tianyang, Zhou; Ling, Zhu; Huiyun, Xia; Jijun, He; Junjie, Zhang

    2014-10-15

    A new selective and sensitive high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for the quantification of natamycin (NAT) in rabbit corneas with amphotericin B as the internal standard (IS). The cornea samples were processed by a simple and protective methanol soaking extraction technology. The NAT could be extracted completely from rabbit cornea after 24h of soaking with methanol under a mild condition. Chromatographic separation was performed on a C18 column (2.1mm×50mm, 3.5μm) using mobile phase with ammonium acetate buffer (pH 4.5; 4.0mM):acetonitrile (40:60, v/v) at a flow rate of 0.25ml/min. Quantification was performed using the transitions 666.2→503.2 m/z for NAT and 924.5→906.6 m/z for IS by positive ion electrospray ionization in multiple reaction monitoring mode. The assay was validated over a concentration range of 8.64ng/ml to 843ng/ml with lower limit of detection of 4.32ng/ml. The method was validated with respect to linearity, accuracy, precision, recovery, stability and extracting efficiency. The extraction recovery of NAT from cornea samples was approximately 100% with the new methanol soaking extraction procedure. The method has been successfully applied to the ocular pharmacokinetic studies of NAT eye drops in the cornea of Japanese white rabbit. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Measurement and modeling of diffusion kinetics of a lipophilic molecule across rabbit cornea.

    Science.gov (United States)

    Gupta, Chhavi; Chauhan, Anuj; Mutharasan, Raj; Srinivas, Sangly P

    2010-04-01

    To develop a kinetic model for representing the diffusion and partitioning of Rhodamine B (RhB), a fluorescent lipophilic molecule, across the cornea for gaining insights into pharmacokinetics of topical drugs to the eye. Rabbit corneas mounted underneath a custom-built scanning microfluorometer were perfused with Ringers on both sides of the tissue. After a step change in RhB on the tear side, transients of trans-corneal fluorescence of RhB were measured at a depth resolution approximately 8 microm. RhB distribution exhibited discontinuities at the interface between epithelium and stroma, and between stroma and endothelium. In each of the layers, fluorescence was non-uniform. Fluorescence was elevated in the epithelium and endothelium relative to the stroma. Modeling of RhB transport by diffusion in each layer and stipulation of partitioning of RhB at the cellular interfaces were required to account for trans-corneal penetration kinetics of RhB. The model parameters, estimated using the unsteady state trans-corneal RhB profiles, were found to be sensitive, and the model predicted the experimental profiles accurately. Conventional pharmacokinetic models that depict cornea as a single compartment do not predict the depth-dependent kinetics of RhB penetration. The proposed model incorporates realistic transport mechanisms and thereby highlights the influence of physicochemical properties of drugs on trans-corneal kinetics.

  8. Influence of the He-Ne laser in different irradiation regimes on the cornea cells after ionizing irradiation

    International Nuclear Information System (INIS)

    Bulyakova, N.V.

    1984-01-01

    A study was made on epithelium cells of the eye cornea in mices entering the first postradiation mitosis. The influence of laser rays acting in the course of each exposure during one and the same period of time, or continuously, or by pulses was compared. The effect of laser radiation was evaluated from the frequency of occurrence of cells with chromosomal aberrations, mitotic index, coefficient of mitosis phases. It has been established that pulse radiation of a helium-neon laser in a certain operation regime produces a sanitating effect on cells of eye cornea epithelium in white mice damaged by ionizing radiation. Cells being killed in the interphase were not revealed in epithelium of the eye cornea. It enables to conclude that the amount of aberrant mitoses decreases as a result of postradiation repair of cells damaged by ionizing radiation, but not as a result of their elimination

  9. A short-term study of corneal collagen cross-linking with hypo-osmolar riboflavin solution in keratoconic corneas

    Directory of Open Access Journals (Sweden)

    Shao-Feng Gu

    2015-02-01

    Full Text Available AIM: To report the 3mo outcomes of collagen cross-linking (CXL with a hypo-osmolar riboflavin in thin corneas with the thinnest thickness less than 400 μm without epithelium. METHODS: Eight eyes in 6 patients with age 26.2±4.8y were included in the study. All patients underwent CXL using a hypo-osmolar riboflavin solution after its de-epithelization. Best corrected visual acuity, manifest refraction, the thinnest corneal thickness, and endothelial cell density were evaluated before and 3mo after the procedure. RESULTS: The mean thinnest thickness of the cornea was 408.5±29.0 μm before treatment and reduced to 369.8±24.8 μm after the removal of epithelium. With the application of the hypo-osmolar riboflavin solution, the thickness increased to 445.0±26.5 μm before CXL and recover to 412.5±22.7 μm at 3mo after treatment, P=0.659. Before surgery, the mean K-value of the apex of the keratoconus corneas was 57.6±4.0 diopters, and slightly decreased (54.7±4.9 diopters after surgery (P=0.085. Mean best-corrected visual acuity was 0.55±0.23 logarithm of the minimal angle of resolution, and increased to 0.53±0.26 logarithm after surgery (P=0.879. The endothelial cell density was 2706.4±201.6 cells/mm2 before treatment, and slightly decreased (2641.2±218.2 cells/mm2 at last fellow up (P=0.002. CONCLUSION: Corneal collagen cross-linking with a hypo-osmolar riboflavin in thin corneas seems to be a promising treatment. Further study should be done to evaluate the safety and efficiency of CXL in thin corneas for the long-term.

  10. Comparison of Scheimpflug imaging parameters between steep and keratoconic corneas of Caucasian eyes

    Directory of Open Access Journals (Sweden)

    Huseynova T

    2016-04-01

    Full Text Available Tukezban Huseynova,1 Farah Abdulaliyeva,2 Michele Lanza3 1Briz-L Eye Clinic, 2National Ophthalmology Center, Baku, Azerbaijan; 3Second University of Naples, Caserta, Campania, Italy Purpose: To compare the keratometric and pachymetric parameters of healthy eyes with those affected by steep cornea and keratoconus (KC using Scheimpflug camera.Setting: Briz-L Eye Clinic, Baku, Azerbaijan.Design: A cross-sectional study.Methods: In this study, 49 KC (Amsler–Krumeich stage 1 eyes and 36 healthy eyes were enrolled. A complete ophthalmic evaluation and a Scheimpflug camera scan were performed in every eye included in the study. Tomographic parameters such as parameters from the front and back cornea, maximum keratometry reading (Kmax, corneal volume (CV, anterior chamber volume (ChV, anterior chamber depth (ACD, anterior chamber angle (AC angle, keratometric power deviation (KPD, maximum front elevation (Max FE, and maximum back elevation (Max BE, as well as pachymetric progression indices (PPI, Ambrosio relational thickness (ART, index of surface variance (ISV, index of vertical asymmetry (IVA, center keratoconus index (CKI, index of height asymmetry (IHA, index of height decentration (IHD, and radius minimum (RM were collected and statistically compared between the two groups.Results: PPI, ART, ISV, IVA, CKI, IHA, IHD, and RM parameter values were significantly different (P<0.05 between the KC and healthy eyes. There were no significant differences in K mean and Q values of the frontal corneal parameters, as well as in Kmax, AC angle, RM, back, and front astigmatism, between stage 1 keratoconic and normal Caucasian eyes with steep cornea. All other parameters such as K mean and Q values of the back corneal parameters, Max FE, Max BE, ACD, ChV, and CV showed significant differences between the groups (P<0.05 for all. Conclusion: Scheimpflug imaging is able to detect corneal morphological differences between stage 1 KC eyes and healthy eyes with

  11. On higher-order boundary conditions at elastic-plastic boundaries in strain-gradient plasticity

    DEFF Research Database (Denmark)

    Niordson, Christian Frithiof

    2008-01-01

    are suppressed by using a very high artificial hardening modulus. Through numerical studies of pure bending under plane strain conditions, it is shown that this method predicts the build-up of higher order stresses in the pseudo-elastic regime. This has the effect of delaying the onset of incipient yield......, as well as extending the plastic zone further toward the neutral axis of the beam, when compared to conventional models. Arguments supporting the present method are presented that rest on both mathematical and physical grounds. The results obtained are compared with other methods for dealing with higher...

  12. Soft Plastic Robots and Artificial Muscles

    Directory of Open Access Journals (Sweden)

    Mohsen Shahinpoor

    2008-11-01

    Full Text Available Ionic polymeric materials suitably made into a functionally-graded composite with a conductor such as a metal, graphite or synthetic metal such as conductive polymers that act as a distributed electrode can exhibit large dynamic deformation if placed in a time-varying electric field (see Fig.s 1and 2 [Shahinpoor 1992, 1993, Adolf, Shahinpoor, Segalman and Witkowski, 1993]. A recent book by Shahinpoor, Kim and Mojarrad (2004 and 4 fundamental review papers by Shahinpoor and Kim (2001, 2003, 2004 and 2005 presents a thorough coverage of the existing knowledge in connection with ionic polymeric cond uctor composites (IPCC?s including ionic polymeric metal composites (IPMC?s as biomimetic distributed nanosensors, nanoactuators and artificial muscles and electrically controllable polymeric network structures. Furthermore, in reference [Shahinpoor, Kim and Mojarrad, 2004], methods of fabrication of several electrically and chemically active ionic polymeric gel muscles such as polyacrylonitrile (PAN, poly(2- acrylamido-2-methyl-1-propane sulfonic acid (PAMPS, and polyacrylic-acid-bis-acrylamide (PAAM as well as a new class of electrically active composite muscle such as Ionic Polymeric Conductor Composites (IPCC?s or Ionic Polymer Metal Composites (IPMC?s made with perfluorinated sulfonic or carboxylic ionic membranes (chlor-alkali family are introduced and investigated that have resulted in seven US patents regarding their fabrication and application capabilities as distributed biomimetic nanoactuators, nanotransducers, nanorobots and nanosensors. Theories and numerical simulations associated with ionic polymer gels electrodynamics and chemodynamics are also discussed, analyzed and modeled for the manufactured material.

  13. Preparation of pre-cut corneas from fresh donated whole globes for Descemet's stripping automated keratoplasty: 3-year results at the Central Eye Bank of Iran.

    Science.gov (United States)

    Kanavi, Mozhgan Rezaei; Javadi, Mohammad Ali; Javadi, Fatemeh; Chamani, Tahereh

    2014-09-01

    To describe the technique and the results of the preparation of pre-cut corneas for Descemet's stripping automated endothelial keratoplasty (DSAEK) during a 3-year period at the Central Eye Bank of Iran (CEBI). The method of preparation of pre-cut corneas from donated whole globes at the CEBI is described and the frequency and percentage of pre-cut corneas prepared for DSAEK, between April 2009 and March 2012, are specified. Moreover, post-operative reports are reviewed for any complaints about using pre-cut tissues for DSAEK. Out of the 1,518 donated whole globes appropriate for DSAEK, 1,478 (97.4 %) pre-cut corneas were successfully prepared. The method of preparation failed in 40 (2.6 %) cases. Based on the eye bank post-operative reports, thickness of pre-cut tissues for DSAEK was deemed unacceptable in only 6 (0.4 %) cases prior to surgery; five of these were too thick and one was too thin. Preparation of pre-cut corneas, for DSAEK from donated whole globes, in the CEBI is a safe and easy method, with very good preservation of endothelial cells after the preparation of the pre-cut corneas and reduced risks from corneal manipulation.

  14. Visual acuity outcomes in eyes with flat corneas after PRK.

    Science.gov (United States)

    Varssano, David; Waisbourd, Michael; Minkev, Liza; Sela, Tzahi; Neudorfer, Meira; Binder, Perry S

    2013-06-01

    To evaluate the impact of corneal curvatures less than 35 diopters (D) after photorefractive keratectomy (PRK) on visual acuity outcomes. Visual acuity outcomes of 5,410 eyes that underwent PRK from January 2006 to November 2010 were retrospectively analyzed for the impact of postoperative corneal curvatures on visual outcomes. All procedures were performed on a single platform (Allegretto 200Hz excimer laser; Alcon Laboratories, Inc., Irvine, CA). Main outcome measures were postoperative corrected distance visual acuity (CDVA) and loss of CDVA. Corneas with a measured or a calculated postoperative flat meridian less than 35 D and those with a measured postoperative steep meridian less than 35 D had worse postoperative CDVA than corneas with meridians of either 35 D or more (P ≤ .021). However, the preoperative CDVA was worse in the flatter curvatures in all comparisons performed (P ≤ .024). Consequently, the measured or calculated meridian curvature had no effect on CDVA loss (P ≥ .074). Postoperative corneal keratometry values (flat and steep meridians) less than 35 D did not have a predictive effect on the risk of losing visual acuity following myopic PRK performed on the Allegretto 200Hz excimer laser. Copyright 2013, SLACK Incorporated.

  15. Effect of In Vitro Transcorneal Approach of Aceclofenac Eye Drops through Excised Goat, Sheep, and Buffalo Corneas

    Directory of Open Access Journals (Sweden)

    Vivek Dave

    2015-01-01

    Full Text Available The current study involves the evaluation of factors that influence the transcorneal permeation of aqueous drops of aceclofenac ophthalmic formulation through freshly excised goat, sheep, and buffalo corneas. Aceclofenac formulation with different concentrations 0.1–0.5% (w/v and with different pH and different preservatives, was taken into account. The amount of drug permeated from different formulations was estimated using an Franz diffusion cell. A linear increase in drug permeation was observed with increase in pH (5.5 to 7.4. The apparent permeability coefficient was found to be maximum 15.01±0.45 on goat cornea and maximum transport of aceclofenac was observed at physiological pH of tears (i.e., 7. The results advocate that aceclofenac 0.5% (w/v ophthalmic solution (pH 7.0 containing BAK (0.01% provides maximum in vitro ocular permeability through goat, sheep, and buffalo corneas.

  16. Removal of a barbed fish hook from the cornea of an 8-year-old boy.

    Science.gov (United States)

    Kemp, Pavlina S; Shah, Ankoor S; Elliott, Alexandra T; Wan, Michael J

    2017-10-01

    This video article shows the surgical removal of a three-pronged barbed fish hook from the cornea and anterior chamber of an 8-year-old boy. The advance-and-cut method is shown: the embedded barbed point of the fish hook was advanced through the cornea, its point was cut off, and the shank of the hook was withdrawn. This method was chosen due to the three-pronged configuration of the fish hook to minimize additional trauma to the eye. Other methods of fish hook removal are briefly reviewed. Copyright © 2017 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  17. Artificial Synapses Based on in-Plane Gate Organic Electrochemical Transistors.

    Science.gov (United States)

    Qian, Chuan; Sun, Jia; Kong, Ling-An; Gou, Guangyang; Yang, Junliang; He, Jun; Gao, Yongli; Wan, Qing

    2016-10-05

    Realization of biological synapses using electronic devices is regarded as the basic building blocks for neuromorphic engineering and artificial neural network. With the advantages of biocompatibility, low cost, flexibility, and compatible with printing and roll-to-roll processes, the artificial synapse based on organic transistor is of great interest. In this paper, the artificial synapse simulation by ion-gel gated organic field-effect transistors (FETs) with poly(3-hexylthiophene) (P3HT) active channel is demonstrated. Key features of the synaptic behaviors, such as paired-pulse facilitation (PPF), short-term plasticity (STP), self-tuning, the spike logic operation, spatiotemporal dentritic integration, and modulation are successfully mimicked. Furthermore, the interface doping processes of electrolyte ions between the active P3HT layer and ion gels is comprehensively studied for confirming the operating processes underlying the conductivity and excitatory postsynaptic current (EPSC) variations in the organic synaptic devices. This study represents an important step toward building future artificial neuromorphic systems with newly emerged ion gel gated organic synaptic devices.

  18. Compounds from multilayer plastic bags cause reproductive failures in artificial insemination.

    Science.gov (United States)

    Nerin, C; Ubeda, J L; Alfaro, P; Dahmani, Y; Aznar, M; Canellas, E; Ausejo, R

    2014-05-09

    High levels of reproductive failure were detected in some Spanish sow farms in the Spring of 2010. Regular returns to estrus and variable reductions in litter size were observed. The problem started suddenly and did not appear to be related to the quality of the ejaculates, disease, alterations of body condition or any other apparent reasons. Subsequent studies determined that the problem was the origin of the plastic bags used for semen storage. Chemical analysis of the suspicious bags identified unexpected compounds such as BADGE, a cyclic lactone and an unknown phthalate that leached into the semen at concentrations of 0.2 to 2.5 mg/L. Spermatozoa preserved in these bags passed all of the routine quality control tests, and no differences were observed between storage in the control and suspicious bags (p > 0.05). In vitro fecundation tests and endocrine profiler panel analysis (EPP) did not show any alterations, whereas the in vivo tests confirmed the described failure. This is the first described relationship between reproductive failure and toxic compounds released from plastic bags.

  19. Compounds from multilayer plastic bags cause reproductive failures in artificial insemination

    Science.gov (United States)

    Nerin, C.; Ubeda, J. L.; Alfaro, P.; Dahmani, Y.; Aznar, M.; Canellas, E.; Ausejo, R.

    2014-05-01

    High levels of reproductive failure were detected in some Spanish sow farms in the Spring of 2010. Regular returns to estrus and variable reductions in litter size were observed. The problem started suddenly and did not appear to be related to the quality of the ejaculates, disease, alterations of body condition or any other apparent reasons. Subsequent studies determined that the problem was the origin of the plastic bags used for semen storage. Chemical analysis of the suspicious bags identified unexpected compounds such as BADGE, a cyclic lactone and an unknown phthalate that leached into the semen at concentrations of 0.2 to 2.5 mg/L. Spermatozoa preserved in these bags passed all of the routine quality control tests, and no differences were observed between storage in the control and suspicious bags (p > 0.05). In vitro fecundation tests and endocrine profiler panel analysis (EPP) did not show any alterations, whereas the in vivo tests confirmed the described failure. This is the first described relationship between reproductive failure and toxic compounds released from plastic bags.

  20. The ultrastructural alterations in rat corneas with experimentally-induced diabetes mellitus

    International Nuclear Information System (INIS)

    Take, G.; Karabay, G.; Erdogan, D.; Duyar, I.

    2006-01-01

    To examine the ultrastructural changes of rat corneas in streptozotocin (STZ) induced diabetes mellitus and the and the follow-up insulin treatment. Sprague-Dawley type rats were used for experimental procedures during the period from January to April 2003 at Baskent University, Ankara, Turkey. Rats were studied in four groups: group 1: controls, group 2 sham controls (single dose IV sodium citrate); group 3 STZ-induced diabetes mellitus (Single dose 45mg/kg STZ intravenously), group 4: diabetes mellitus + insulin treatment (8U/day). We observed degenerative changes in the epithelial layer, stromal keratocytes and endothelial cells in diabetic group. In contrast, the corneal layers have revealed positive alterations in the insulin-treated group. The statistical analysis, showed significant narrowing in the epithelial layer in the diabetic group (p0.02), whereas thickening was observed in the epithelial basement membrane and Descemet's membrane (p=0.002). It was determined that that diabetes mellitus causes degenerative changes in cornea, which are positively influenced by short-term insulin treatment. (author)

  1. [Evaluation of Iris Morphology Viewed through Stromal Edematous Corneas by Infrared Camera].

    Science.gov (United States)

    Kobayashi, Masaaki; Morishige, Naoyuki; Morita, Yukiko; Yamada, Naoyuki; Kobayashi, Motomi; Sonoda, Koh-Hei

    2016-02-01

    We reported that the application of infrared camera enables us to observe iris morphology in Peters' anomaly through edematous corneas. To observe the iris morphology in bullous keratopathy or failure grafts with an infrared camera. Eleven bullous keratopathy or failure grafts subjects (6 men and 5 women, mean age ± SD; 72.7 ± 13.0 years old) were enrolled in this study. The iris morphology was observed by applying visible light mode and near infrared light mode of infrared camera (MeibomPen). The detectability of pupil shapes, iris patterns and presence of iridectomy was evaluated. Infrared mode observation enabled us to detect the pupil shapes in 11 out of 11 cases, iris patterns in 3 out of 11 cases, and presence of iridetomy in 9 out of 11 cases although visible light mode observation could not detect any iris morphological changes. Applying infrared optics was valuable for observation of the iris morphology through stromal edematous corneas.

  2. Plasticity in memristive devices for Spiking Neural Networks

    Directory of Open Access Journals (Sweden)

    Sylvain eSaïghi

    2015-03-01

    Full Text Available Memristive devices present a new device technology allowing for the realization of compact nonvolatile memories. Some of them are already in the process of industrialization. Additionally, they exhibit complex multilevel and plastic behaviors, which make them good candidates for the implementation of artificial synapses in neuromorphic engineering. However, memristive effects rely on diverse physical mechanisms, and their plastic behaviors differ strongly from one technology to another. Here, we present measurements performed on different memristive devices and the opportunities that they provide. We show that they can be used to implement different learning rules whose properties emerge directly from device physics: real time or accelerated operation, deterministic or stochastic behavior, long term or short term plasticity. We then discuss how such devices might be integrated into a complete architecture. These results highlight that there is no unique way to exploit memristive devices in neuromorphic systems. Understanding and embracing device physics is the key for their optimal use.

  3. Analysis of the Viscoelastic Properties of the Human Cornea Using Scheimpflug Imaging in Inflation Experiment of Eye Globes

    Science.gov (United States)

    Lombardo, Giuseppe; Serrao, Sebastiano; Rosati, Marianna; Lombardo, Marco

    2014-01-01

    Purpose To demonstrate a Scheimpflug-based imaging procedure for investigating the depth- and time-dependent strain response of the human cornea to inflation testing of whole eye globes. Methods Six specimens, three of which with intact corneal epithelium, were mounted in a customized apparatus within a humidity and temperature-monitored wet chamber. Each specimen was subjected to two mechanical tests in order to measure corneal strain resulting from application of cyclic (cyclic regimen) and constant (creep regimen) stress by changing the intra-ocular pressure (IOP) within physiological ranges (18–42 mmHg). Corneal shape changes were analyzed as a function of IOP and both corneal stress-strain curves and creep curves were generated. Results The procedure was highly accurate and repeatable. Upon cyclic stress application, a biomechanical corneal elasticity gradient was found in the front-back direction. The average Young's modulus of the anterior cornea ranged between 2.28±0.87 MPa and 3.30±0.90 MPa in specimens with and without intact epithelium (P = 0.05) respectively. The Young's modulus of the posterior cornea was on average 0.21±0.09 MPa and 0.17±0.06 MPa (P>0.05) respectively. The time-dependent strain response of the cornea to creep testing was quantified by fitting data to a modified Zener model for extracting both the relaxation time and compliance function. Conclusion Cyclic and creep mechanical tests are valuable for investigating the strain response of the intact human cornea within physiological IOP ranges, providing meaningful results that can be translated to clinic. The presence of epithelium influences the results of anterior corneal shape changes when monitoring deformation via Scheimpflug imaging in inflation experiments of whole eye globes. PMID:25397674

  4. Biophysico-functional compatibility of Seoul National University (SNU) miniature pig cornea as xenocorneal graft for the use of human clinical trial.

    Science.gov (United States)

    Kim, Dong Hyun; Kim, Jaeyoung; Jeong, Hyun Jeong; Lee, Hyun Ju; Kim, Mee Kum; Wee, Won Ryang

    2016-05-01

    Xenocorneal transplantation is one of the solutions for shortage of donor cornea, and remarkable advances have been made in pig-to-rhesus studies from the immunological perspective. Most successful preclinical trials have been carried out with corneas of the Seoul National University (SNU) miniature pig (SNU pig, genetically unmodified) as donor tissues; however, there has been no biophysico-functional evaluation of the SNU pig cornea as a substitute for human cornea. The purpose of this study was to investigate the biophysical and functional compatibility of SNU pig cornea for use in human clinical trials. Ninety-three eyeballs obtained from 51 SNU pigs were used to evaluate the physical properties and changes in porcine corneal endothelial cells (PCECs) depending on preservation time and storage condition before surgery, proliferative and functional characteristics of PCECs, and the microbiologic safety of porcine cornea. Corneal diameters and curvatures, axial length, anterior chamber depth, and central corneal thickness were measured and compared with previously reported human data. Corneal endothelial cell density (ECD) was serially measured with a confocal microscope during 7 days of preservation in the same storage solution used for human corneas. Corneal endothelial cell proliferation and immunofluorescence staining of Na- and K-dependent ATPase in PCECs were evaluated after 7 days of preservation. The corneoscleral rims of SNU pigs were cultured for gram-positive bacteria, gram-negative bacteria, and fungi to evaluate their microbiological safety. Corneal diameter and thickness in SNU pigs was larger than human and corneal curvature was flatter; however, they were within surgically operable ranges. Mean ECD (day 0) and ECD loss after 7 days of preservation were 2625 ± 81 cells/mm(2) and 7.60 ± 1.53%, respectively, which is comparable to human ECD and ECD loss in the same conditions. The ECD of SNU pigs was inversely decreased with aging (R(2) = 0.4034, P

  5. Fibre optic spectrophotometry for the in vitro evaluation of ultraviolet radiation (UVR) spectral transmittance of rabbit corneas

    International Nuclear Information System (INIS)

    Walsh, J E; Fleming, D P; Bergmanson, J P G; Koehler, L V; Doughty, M J; Harmey, J H

    2008-01-01

    A fibre optic spectrophotometer front-end system for measuring corneas to overcome shortcomings associated with existing instruments was tested. The system allowed prompt measurement postmortem, minimizing beam pathlength to reduce the effects of scatter and unwanted refraction and eliminated optical interfaces and cuvette media. Rabbit corneas were excised immediately postmortem and placed on a detecting fibre optic coupled to an Ocean Optics spectrophotometer and illuminated by a deuterium–halogen source. The compact instrument with its small beam size allowed tissue profiling at test points across the corneal surface and efficient interchange for comparison of different tissues. This simplified system operation allowed rapid tissue altering to study induced changes on transmittance. The corneal transmittance data showed a consistent sharp cut-off at 320 nm in the ultraviolet radiation (UVR) spectrum, which decayed rapidly from postmortem swelling. Inter- and intra-corneal consistency was demonstrated by comparing data from different regions of the same cornea and those from opposite eyes. Changes to the spectra, particularly in the UVB below 300 nm, were evident when the corneal epithelium was removed, indicating that this layer is not the only corneal UVR filter. The new system reduced much of the variability associated with previous methods, as it rapidly measured corneal transmittance postmortem. Data are in broad agreement with published transmittance curves. The removal of the corneal epithelium revealed a substantial stromal contribution to the overall corneal UVR absorption, suggesting that corneas with pathologically or iatrogenically thinned stromas are less effective UVR blockers

  6. 3D refraction correction and extraction of clinical parameters from spectral domain optical coherence tomography of the cornea.

    Science.gov (United States)

    Zhao, Mingtao; Kuo, Anthony N; Izatt, Joseph A

    2010-04-26

    Capable of three-dimensional imaging of the cornea with micrometer-scale resolution, spectral domain-optical coherence tomography (SDOCT) offers potential advantages over Placido ring and Scheimpflug photography based systems for accurate extraction of quantitative keratometric parameters. In this work, an SDOCT scanning protocol and motion correction algorithm were implemented to minimize the effects of patient motion during data acquisition. Procedures are described for correction of image data artifacts resulting from 3D refraction of SDOCT light in the cornea and from non-idealities of the scanning system geometry performed as a pre-requisite for accurate parameter extraction. Zernike polynomial 3D reconstruction and a recursive half searching algorithm (RHSA) were implemented to extract clinical keratometric parameters including anterior and posterior radii of curvature, central cornea optical power, central corneal thickness, and thickness maps of the cornea. Accuracy and repeatability of the extracted parameters obtained using a commercial 859nm SDOCT retinal imaging system with a corneal adapter were assessed using a rigid gas permeable (RGP) contact lens as a phantom target. Extraction of these parameters was performed in vivo in 3 patients and compared to commercial Placido topography and Scheimpflug photography systems. The repeatability of SDOCT central corneal power measured in vivo was 0.18 Diopters, and the difference observed between the systems averaged 0.1 Diopters between SDOCT and Scheimpflug photography, and 0.6 Diopters between SDOCT and Placido topography.

  7. The tissue-engineered human cornea as a model to study expression of matrix metalloproteinases during corneal wound healing.

    Science.gov (United States)

    Couture, Camille; Zaniolo, Karine; Carrier, Patrick; Lake, Jennifer; Patenaude, Julien; Germain, Lucie; Guérin, Sylvain L

    2016-02-01

    Corneal injuries remain a major cause of consultation in the ophthalmology clinics worldwide. Repair of corneal wounds is a complex mechanism that involves cell death, migration, proliferation, differentiation, and extracellular matrix (ECM) remodeling. In the present study, we used a tissue-engineered, two-layers (epithelium and stroma) human cornea as a biomaterial to study both the cellular and molecular mechanisms of wound healing. Gene profiling on microarrays revealed important alterations in the pattern of genes expressed by tissue-engineered corneas in response to wound healing. Expression of many MMPs-encoding genes was shown by microarray and qPCR analyses to increase in the migrating epithelium of wounded corneas. Many of these enzymes were converted into their enzymatically active form as wound closure proceeded. In addition, expression of MMPs by human corneal epithelial cells (HCECs) was affected both by the stromal fibroblasts and the collagen-enriched ECM they produce. Most of all, results from mass spectrometry analyses provided evidence that a fully stratified epithelium is required for proper synthesis and organization of the ECM on which the epithelial cells adhere. In conclusion, and because of the many characteristics it shares with the native cornea, this human two layers corneal substitute may prove particularly useful to decipher the mechanistic details of corneal wound healing. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Successful treatment of Fusarium keratitis with cornea transplantation and topical and systemic voriconazole.

    NARCIS (Netherlands)

    Klont, R.R.; Eggink, C.A.; Rijs, A.J.M.M.; Wesseling, P.; Verweij, P.E.

    2005-01-01

    A case of invasive Fusarium keratitis in a previously healthy male patient was treated successfully with cornea transplantation and systemic and topical voriconazole after treatment failure with topical amphotericin B and systemic itraconazole. Topical voriconazole was well tolerated, and, in

  9. Calcite/aragonite-biocoated artificial coral reefs for marine parks

    Directory of Open Access Journals (Sweden)

    Volodymyr Ivanov

    2017-08-01

    Full Text Available Natural formation of the coral reefs is complicated by slow biomediated precipitation of calcium carbonate from seawater. Therefore, manufactured artificial coral reefs can be used for the formation of “underwater gardens” in marine parks for the recreational fishing and diving that will protect natural coral reefs from negative anthropogenic effects. Additionally, the coating of the concrete, plastic or wooden surfaces of artificial coral reef with calcium carbonate layer could promote attachment and growth of coral larvae and photosynthetic epibiota on these surfaces. Three methods of biotechnological coating of the artificial coral reefs have been tested: (1 microbially induced calcium carbonate precipitation from concentrated calcium chloride solution using live bacterial culture of Bacillus sp. VS1 or dead but urease-active cells of Yaniella sp. VS8; (2 precipitation from calcium bicarbonate solution; (3 precipitation using aerobic oxidation of calcium acetate by bacteria Bacillus ginsengi strain VSA1. The thickness of biotechnologically produced calcium carbonate coating layer was from 0.3 to 3 mm. Biocoating using calcium salt and urea produced calcite in fresh water and aragonite in seawater. The calcium carbonate-coated surfaces were colonized in aquarium with seawater and hard corals as inoculum or in aquarium with fresh water using cyanobacteria Chlorella sorokiana as inoculum. The biofilm on the light-exposed side of calcium carbonate-coated surfaces was formed after six weeks of incubation and developed up to the average thickness of 250 µm in seawater and about 150 µm in fresh water after six weeks of incubation. The biotechnological manufacturing of calcium carbonate-coated concrete, plastic, or wooden surfaces of the structures imitating natural coral reef is technologically feasible. It could be commercially attractive solution for the introduction of aesthetically pleasant artificial coral reefs in marine parks and

  10. The Effect of Systemic Amantadine Sulfate on Malondialdehyde and Total Thiol Levels in Rat Corneas

    Directory of Open Access Journals (Sweden)

    Züleyha Yalniz-Akkaya

    2014-01-01

    Full Text Available Purpose: To evaluate the malondialdehyde (MDA and total thiol (sulfhydryl, SH levels in rat corneas after intraperitoneal injection of amantadine sulfate. Methods: A total of 12 Wistar albino rats were divided into two groups: control group (n = 6 and amantadine group (n = 6. Balanced salt solution (1 mL, 0.9% NaCl, twice/day was injected into rats in control group. Amantadine sulfate (2 mg/1 mL, twice/day was injected into rats in amantadine group. In each group, two rats were injected for 1 week, two received injections for 1 month, and two rats received injections for 3 months. The corneas were homogenized and MDA and SH levels were measured spectroflourometrically. Results: In control group, median MDA and SH levels were 2.37 (range, 0.92-3.60 and 25.35 (range, 6.30-54.0 nmol/mg, respectively. In amantadine group, median MDA and SH levels were 3.57 (range, 1.25-5.92 and 32.65 (range, 3.30-48.3 nmol/mg, respectively. The difference between this two groups regarding MDA (P = 0.14 and SH (P = 1.0 levels was statistically insignificant. Conclusion: Systemically administered amantadine sulfate seems not to cause MDA and SH imbalance in rat corneas.

  11. Rocking media over ex vivo corneas improves this model and allows the study of the effect of proinflammatory cytokines on wound healing.

    Science.gov (United States)

    Deshpande, Pallavi; Ortega, Ílida; Sefat, Farshid; Sangwan, Virender S; Green, Nicola; Claeyssens, Frederik; MacNeil, Sheila

    2015-02-05

    The aim of this work was to develop an in vitro cornea model to study the effect of proinflammatory cytokines on wound healing. Initial studies investigated how to maintain the ex vivo models for up to 4 weeks without loss of epithelium. To study the effect of cytokines, corneas were cultured with the interleukins IL-17A, IL-22, or a combination of IL-17A and IL-22, or lipopolysaccharide (LPS). The effect of IL-17A on wound healing was then examined. With static culture conditions, organ cultures deteriorated within 2 weeks. With gentle rocking of media over the corneas and carbon dioxide perfusion, the ex vivo models survived for up to 4 weeks without loss of epithelium. The cytokine that caused the most damage to the cornea was IL-17A. Under static conditions, wound healing of the central corneal epithelium occurred within 9 days, but only a single-layered epithelium formed whether the cornea was exposed to IL-17A or not. With rocking of media gently over the corneas, a multilayered epithelium was achieved 9 days after wounding. In the presence of IL-17A, however, there was no wound healing evident. Characterization of the cells showed that wherever epithelium was present, both differentiated cells and highly proliferative cells were present. We propose that introducing rocking to extend the effective working life of this model and the introduction of IL-17A to this model to induce aspects of inflammation extend its usefulness to study the effects of agents that influence corneal regeneration under normal and inflamed conditions. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.

  12. Global change and the evolution of phenotypic plasticity in plants.

    Science.gov (United States)

    Matesanz, Silvia; Gianoli, Ernesto; Valladares, Fernando

    2010-09-01

    Global change drivers create new environmental scenarios and selective pressures, affecting plant species in various interacting ways. Plants respond with changes in phenology, physiology, and reproduction, with consequences for biotic interactions and community composition. We review information on phenotypic plasticity, a primary means by which plants cope with global change scenarios, recommending promising approaches for investigating the evolution of plasticity and describing constraints to its evolution. We discuss the important but largely ignored role of phenotypic plasticity in range shifts and review the extensive literature on invasive species as models of evolutionary change in novel environments. Plasticity can play a role both in the short-term response of plant populations to global change as well as in their long-term fate through the maintenance of genetic variation. In new environmental conditions, plasticity of certain functional traits may be beneficial (i.e., the plastic response is accompanied by a fitness advantage) and thus selected for. Plasticity can also be relevant in the establishment and persistence of plants in novel environments that are crucial for populations at the colonizing edge in range shifts induced by climate change. Experimental studies show taxonomically widespread plastic responses to global change drivers in many functional traits, though there is a lack of empirical support for many theoretical models on the evolution of phenotypic plasticity. Future studies should assess the adaptive value and evolutionary potential of plasticity under complex, realistic global change scenarios. Promising tools include resurrection protocols and artificial selection experiments. © 2010 New York Academy of Sciences.

  13. Brittle Cornea Syndrome Associated with a Missense Mutation in the Zinc-Finger 469 Gene

    DEFF Research Database (Denmark)

    Christensen, Anne Elisabeth; Knappskog, Per Morten; Midtbø, Marit

    2010-01-01

    Purpose: To investigate the diverse clinical manifestations, identify the causative mutation and explain the association with red hair in a family with brittle cornea syndrome (BCS). Methods: Eight family members in three generations underwent ophthalmic, dental, and general medical examination...... mapping with SNP markers, DNA sequencing, and MC1R genotyping. Results: At 42 and 48 years of age, respectively, both affected individuals were blind due to retinal detachment and secondary glaucoma. They had extremely thin and bulging corneas, velvety skin, chestnut colored hair, scoliosis, reduced BMD......, dental anomalies, hearing loss and minor cardiac defects. The morphologies of the skin biopsies were normal except that in some areas slightly thinner collagen fibrils were seen in one of the affected individuals. Molecular genetic analysis revealed a novel missense mutation of ZNF469, c.10016G...

  14. Clinical and epidemiological aspects of cornea transplant patients of a reference hospital.

    Science.gov (United States)

    Cruz, Giovanna Karinny Pereira; Azevedo, Isabelle Campos de; Carvalho, Diana Paula de Souza Rego Pinto; Vitor, Allyne Fortes; Santos, Viviane Euzébia Pereira; Ferreira, Marcos Antonio

    2017-06-08

    clinically characterizing cornea transplant patients and their distribution according to indicated and post-operative conditions of cornea transplantation, as well as estimating the average waiting time. a cross-sectional, descriptive and analytical study performed for all cornea transplants performed at a reference service (n=258). Data were analyzed using Statistical Package for the Social Sciences, version 20.0. the main indicator for cornea transplant was keratoconus. The mean waiting time for the transplant was approximately 5 months and 3 weeks for elective transplants and 9 days for urgent cases. An association between the type of corneal disorder with gender, age, previous surgery, eye classification, glaucoma and anterior graft failure were found. keratoconus was the main indicator for cornea transplant. Factors such as age, previous corneal graft failure (retransplantation), glaucoma, cases of surgeries prior to cornea transplant (especially cataract surgery) may be related to the onset corneal endothelium disorders. caracterizar clínicamente los pacientes trasplantados y su distribución, con descripción de las condiciones indicadoras y posoperatorias de los trasplantes de córneas, así como estimar el tiempo promedio en la fila de espera. estudio epidemiológico, transversal, descriptivo y analítico, realizado con todos los trasplantes de córnea realizados en un servicio de referencia (n=258). Los datos fueron analizados con el software Statistical Package for the Social Sciences, versión 20.0. la principal condición indicadora para el trasplante de córnea fue el queratocono. El tiempo promedio en fila de espera para realización del trasplante fue de aproximadamente 5 meses y tres semanas, para trasplantes electivos y de 9 días para los casos de urgencia. Existió asociación entre el tipo de disturbio de la córnea con: sexo, intervalo etario, cirugía previa, clasificación del ojo, glaucoma y rechazo del injerto anterior. el queratocono fue

  15. Cornea and anterior eye assessment with placido-disc keratoscopy, slit scanning evaluation topography and scheimpflug imaging tomography.

    Science.gov (United States)

    Martin, Raul

    2018-03-01

    Current corneal assessment technologies make the process of corneal evaluation extremely fast and simple and several devices and technologies allow to explore and to manage patients. The purpose of this special issue is to present and also to update in the evaluation of cornea and ocular surface and this second part, reviews a description of the corneal topography and tomography techniques, providing updated information of the clinical recommendations of these techniques in eye care practice. Placido-based topographers started an exciting anterior corneal surface analysis that allows the development of current corneal tomographers that provide a full three-dimensional reconstruction of the cornea including elevation, curvature, and pachymetry data of anterior and posterior corneal surfaces. Although, there is not an accepted reference standard technology for corneal topography description and it is not possible to determine which device produces the most accurate topographic measurements, placido-based topographers are a valuable technology to be used in primary eye care and corneal tomograhers expanding the possibilities to explore cornea and anterior eye facilitating diagnosis and follow-up in several situations, raising patient follow-up, and improving the knowledge regarding to the corneal anatomy. Main disadvantages of placido-based topographers include the absence of information about the posterior corneal surface and limited corneal surface coverage without data from the para-central and/or peripheral corneal surface. However, corneal tomographers show repeatable anterior and posterior corneal surfaces measurements, providing full corneal thickness data improving cornea, and anterior surface assessment. However, differences between devices suggest that they are not interchangeable in clinical practice.

  16. Eye evolution: lens and cornea as an upgrade of animal visual system

    Czech Academy of Sciences Publication Activity Database

    Jonášová, Kristýna; Kozmik, Zbyněk

    2008-01-01

    Roč. 19, č. 2 (2008), s. 71-81 ISSN 1084-9521 R&D Projects: GA AV ČR IAA500520604; GA MŠk(CZ) 1M0520 Institutional research plan: CEZ:AV0Z50520514 Keywords : eye * lens * cornea Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 4.528, year: 2008

  17. Pathways and Mechanisms Underlying the Photophysics and Photochemistry of Riboflavin induced cornea crosslinking

    DEFF Research Database (Denmark)

    Breitenbach, Thomas; Ogilby, Peter Remsen

    In this talk, we will describe general pathways involved in the photophysics of a photosensitized process, which can lead to crosslinking due to light excitation of Riboflavin in the cornea. Furthermore, we will elucidate different aspects of reactions that can produce crosslinks, with respect...

  18. Effects of epidermal growth factor in artificial tear on vitamin C levels of corneal wounded eye tissues.

    Science.gov (United States)

    Gönül, B; Kaplan, B; Bilgihan, K; Budak, M T

    2001-04-01

    To investigate the effect of artificial tear (AT) solution and epidermal growth factor (EGF) treatment on the cornea and aqueous humour ascorbic acid (AA) levels of full-thickness corneal wounded eyes. The effect of EGF on the AA levels of aqueous humour and corneal wound tissue was determined in full-thickness corneal wounded rabbit eyes on the seventh post-operative day. There were three groups: untreated controls, AT-treated controls and an EGF+AT-treated experimental group (n = 6 in each group). Corneal wounded eyes were topically treated with 5 microl AT or 5 microl EGF in AT (1 mg/l EGF in AT prepaaration which contained 3.0% carbopol 940) twice daily for 6 days after operation. The wound strengths were also measured on the seventh post-operative day as a measure of wound healing. Statistical analysis was carried out using the Mann-Whitney U-test by Statview program. The wound strengths of corneas, and AA levels of wound tissues and aqueous humour, increased significantly following AT and EGF treatment (p < 0.05). In the corneal wounded eye, aqueous humour serves as a source of vitamin C and there may be a relation between EGF treatment in AT and AA levels of corneal wounded eye tissues.

  19. Novel microemulsion in situ electrolyte-triggered gelling system for ophthalmic delivery of lipophilic cyclosporine A: in vitro and in vivo results.

    Science.gov (United States)

    Gan, Li; Gan, Yong; Zhu, Chunliu; Zhang, Xinxin; Zhu, Jiabi

    2009-01-05

    The objective of the present study was to design a novel microemulsion in situ electrolyte-triggered gelling system for ophthalmic delivery of a lipophilic drug, cyclosporine A (CsA). A CsA-loaded microemulsion was prepared using castor oil, Solutol HS 15 (surfactant), glycerol and water. This microemulsion was then dispersed in a Kelcogel solution to form the final microemulsion in situ electrolyte-triggered gelling system. In vitro, the viscosity of the CsA microemulsion Kelcogel system increased dramatically on dilution with artificial tear fluid and exhibited pseudo-plastic rheology. In vivo results revealed that the AUC(0-->32 h) of corneal CsA for the microemulsion Kelcogel system was approximately three-fold greater than for a CsA emulsion. Moreover, at 32 h after administration, CsA concentrations delivered by the microemulsion Kelcogel system remained at therapeutic levels in the cornea. This CsA microemulsion in situ electrolyte-triggered gelling system might provide an alternative approach to deliver prolonged precorneal residence time of CsA for preventing cornea allograft rejection.

  20. [Current approaches to evaluating the anatomic and functional status of the cornea].

    Science.gov (United States)

    Avetisov, S E; Borodina, N V; Kobzova, M V; Musaeva, G M

    2010-01-01

    The review provides data on current methods for evaluating the anatomic and functional status of the cornea (light refraction, light transmission, and biomechanical properties, in particular). It analyzes the main advantages and disadvantages of basic (biomicroscopy, endothelial microscopy, ophthalmometry, topography, and pachymetry) and special (confocal microscopy, optical coherence tomography, ultrasound biomicroscopy, aberrometry, bidirectional corneal applanation, and keratoesthesiometry) studies.

  1. Exploration of alternative test methods to evaluate phototoxicity of ophthalmic agents by using Statens Seruminstitut Rabbit Cornea cell lines and 3D human reconstituted cornea models.

    Directory of Open Access Journals (Sweden)

    Soyoung Kim

    Full Text Available Many chemicals have been reported to induce phototoxicity. The absorbance of light energy within the sunlight range is a common characteristic of phototoxicity. The 3T3 NRU phototoxicity test (PT in 3T3 mouse skin fibroblasts has been used to identify the phototoxic potential induced by excited chemicals after exposure to ultra violet (UV. However, as phototoxicity may occur in ocular cells, it is necessary to develop a more suitable test for cornea-derived cells. In this study, we attempted to establish a new in vitro PT method in rabbit corneal cell lines (SIRC. We evaluated five ophthalmic agents, ciprofloxacin, levofloxacin, lomefloxacin, norfloxacin, and tetracycline, for their cytotoxic potential and in vitro phototoxicity. The results obtained using 3D human corneal models revealed that the UV-induced eye tissue toxicity by the test substances showed good correlation with those obtained using the in vitro phototoxicity test. However, the results from the 3D PT for ciprofloxacin, norfloxacin, and tetracycline in the 3D human cornea model were only partially comparable. Therefore, we suggest the SIRC cell line as a new phototoxicity test model; however, a sequential testing strategy, such as 3D PT, was also proposed to obtain relevant information for topical eye agents.

  2. Transcriptome Profiling of Neovascularized Corneas Reveals miR-204 as a Multi-target Biotherapy Deliverable by rAAVs

    Directory of Open Access Journals (Sweden)

    Yi Lu

    2018-03-01

    Full Text Available Corneal neovascularization (NV is the major sight-threatening pathology caused by angiogenic stimuli. Current drugs that directly target pro-angiogenic factors to inhibit or reverse the disease require multiple rounds of administration and have limited efficacies. Here, we identify potential anti-angiogenic corneal microRNAs (miRNAs and demonstrate a framework that employs discovered miRNAs as biotherapies deliverable by recombinant adeno-associated viruses (rAAVs. By querying differentially expressed miRNAs in neovascularized mouse corneas induced by alkali burn, we have revealed 39 miRNAs that are predicted to target more than 5,500 differentially expressed corneal mRNAs. Among these, we selected miR-204 and assessed its efficacy and therapeutic benefit for treating injured corneas. Our results show that delivery of miR-204 by rAAV normalizes multiple novel target genes and biological pathways to attenuate vascularization of injured mouse cornea. Importantly, this gene therapy treatment alternative is efficacious and safe for mitigating corneal NV. Overall, our work demonstrates the discovery of potential therapeutic miRNAs in corneal disorders and their translation into viable treatment alternatives.

  3. Public Health Implications of the 1540 nm Laser on the Cornea

    Science.gov (United States)

    2007-05-30

    of Public Health Degree 30 May 2007 - Thomas J01vfson, Ph.D. Department of Preventive Medicine & Biometrics Committee Member Christine Kasper, ’,D...Xu and Alfano 2005) This absorption characteristic is useful in refractive surgery of the eye because the cornea is approximately 80% water...retina. Invest Ophthalmol Vis Sci 35: 3032-44; 1994. Xu M, Alfano RR. Fractal mechanisms of light scattering in biological tissue and cells. Opt

  4. VRP09 Reduction of Corneal Scarring Following Blast and Burn Injuries to Cornea Using siRNAs Targeting TGFb and CTGF

    Science.gov (United States)

    2013-03-01

    aSMA ) synthesis. Second, we proposed to develop an advanced ex vivo organ culture system using viable explants of rabbit corneas, and assess the...effect of the most effective triple siRNA combination for reduction of target genes, collagen and alpha smooth muscle actin ( aSMA ) in rabbit corneas...targeting three key genes (TGFb, TGFbRII, and CTGF) that synergistically reduces the level of mRNAs for type I collagen gene and aSMA by >95% without

  5. Entertainment-education and recruitment of cornea donors: the role of emotion and issue involvement.

    Science.gov (United States)

    Bae, Hyuhn-Suhck

    2008-01-01

    This study examined the role of emotional responses and viewer's level of issue involvement to an entertainment-education show about cornea donation in order to predict intention to register as cornea donors. Results confirmed that sympathy and empathy responses operated as a catalyst for issue involvement, which emerged as an important intermediary in the persuasion process. Issue involvement also was found to be a common causal antecedent of attitude, subjective norm, and perceived behavioral control, the last two of which predict intentions unlike attitude, which does not. The revised path model confirmed that involvement directly influences intention. The findings of this study suggest that adding emotion and involvement in the Theory of Planned Behavior (TPB) enhances the explanatory power of the theory in predicting intentions, which indicates the possibility of combining the Elaboration Likelihood Model (ELM) and the TPB in the prediction of human behaviors.

  6. Accelerated age hardening by plastic deformation in Al-Cu with minor additions of Si and Ge

    International Nuclear Information System (INIS)

    Victoria Castro Riglos, M.; Taquire de la Cruz, M.; Tolley, Alfredo

    2011-01-01

    An extremely fast hardening response with no reduction in peak hardness was obtained in Al-Cu with minor additions of Si and Ge by 8% plastic deformation before artificial aging. The mechanism for the accelerated hardening was determined by detailed characterization with transmission electron microscopy. Plastic deformation was found to enhance the nucleation rate of Si-Ge precipitates, resulting in a higher volume density. Such precipitates catalyzed the formation of θ' precipitates that are responsible for hardening.

  7. Desiccating Stress-Induced MMP Production and Activity Worsens Wound Healing in Alkali-Burned Corneas

    Science.gov (United States)

    Bian, Fang; Pelegrino, Flavia S. A.; Pflugfelder, Stephen C.; Volpe, Eugene A.; Li, De-Quan; de Paiva, Cintia S.

    2015-01-01

    Purpose To evaluate the effects of dry eye on ocular surface protease activity and sight threatening corneal complications following ocular surface chemical injury. Methods C57BL/6 mice were subjected to unilateral alkali burn (AB) with or without concomitant dry eye for 2 or 5 days. Mice were observed daily for appearance of corneal perforation. Whole corneas were harvested and lysed for RNA extraction. Quantitative real-time PCR was performed to measure expression of inflammation cytokines, matrix metalloproteinases (MMP). Matrix metalloproteinase–9 activity, gelatinase activity, and myeloperoxidase (MPO) activity were evaluated in corneal lysates. Presence of infiltrating neutrophils was evaluated by immunohistochemistry and flow cytometry. Results Eyes subjected to the combined model of AB and dry eye (CM) had 20% sterile corneal perforation rate as soon as 1 day after the initial injury, which increased to 35% by 5 days, delayed wound closure and increased corneal opacity. Increased levels of IL-1β, -6, and MMPs-1, -3, -8, -9, and -13, and chemokine (C-X-C motif) ligand 1 (CSCL1) transcripts were found after 2 days in CM compared with AB corneas. Increased MMP-1, -3, -9, and -13 immunoreactivity and gelatinolytic activity were seen in CM corneas compared with AB. Increased neutrophil infiltration and MPO activity was noted in the CM group compared with AB 2 days post injury. Conclusions Desiccating stress worsens outcome of ocular AB, creating a cytokine and protease storm with greater neutrophil infiltration, increasing the risk of corneal perforation. PMID:26225631

  8. Application of fluidization to separate packaging waste plastics.

    Science.gov (United States)

    Carvalho, M Teresa; Ferreira, Célia; Portela, Antía; Santos, João Tiago

    2009-03-01

    The objective of the experimental work described in this paper is the study of the separation of PS (polystyrene) from PET (polyethylene terephthalate) and PVC (polyvinyl chloride) from drop-off points using a fluidized bed separator. This is a low-cost process commonly used in the hydro-classification of mineral ores. Firstly, experimental tests were carried out with artificial granulated samples with different grain sizes, types and sources of plastic ("separability tests"). The particle settling velocities were determined under different operating conditions. Then, based on the results, the laboratory tests continued with real mixtures of waste plastics ("separation tests") and the efficiency of the process was evaluated. From a PET-rich mixture, a concentrate of PS with a 75% grade in PS was produced while the underflow was quite clear from PS (grade less than 0.5% in PS).

  9. Ion Permeability of Artificial Membranes Evaluated by Diffusion Potential and Electrical Resistance Measurements

    Science.gov (United States)

    Shlyonsky, Vadim

    2013-01-01

    In the present article, a novel model of artificial membranes that provides efficient assistance in teaching the origins of diffusion potentials is proposed. These membranes are made of polycarbonate filters fixed to 12-mm plastic rings and then saturated with a mixture of creosol and "n"-decane. The electrical resistance and potential…

  10. Experimental study on the healing process following laser welding of the cornea.

    Science.gov (United States)

    Rossi, Francesca; Pini, Roberto; Menabuoni, Luca; Mencucci, Rita; Menchini, Ugo; Ambrosini, Stefano; Vannelli, Gabriella

    2005-01-01

    An experimental study evaluating the application of laser welding of the cornea and the subsequent healing process is presented. The welding of corneal wounds is achieved after staining the cut walls with a solution of the chromophore indocyanine green, and irradiating them with a diode laser (810 nm) operating at low power (60 to 90 mW). The result is a localized heating of the cut, inducing controlled welding of the stromal collagen. In order to optimize this technique and to study the healing process, experimental tests, simulating cataract surgery and penetrating keratoplasty, were performed on rabbits: conventional and laser-induced suturing of corneal wounds were thus compared. A follow-up study 7 to 90 days after surgery was carried out by means of objective and histological examinations, in order to optimize the welding technique and to investigate the subsequent healing process. The analyses of the laser-welded corneas evidenced a faster and more effective restoration of the architecture of the stroma. No thermal damage of the welded stroma was detected, nor were there foreign body reactions or other inflammatory processes. Copyright 2005 Society of Photo-Optical Instrumentation Engineers.

  11. Plastic

    International Nuclear Information System (INIS)

    Jeong Gi Hyeon

    1987-04-01

    This book deals with plastic, which includes introduction for plastic, chemistry of high polymers, polymerization, speciality and structure of a high molecule property of plastic, molding, thermosetting plastic, such as polyethylene, polyether, polyamide and polyvinyl acetyl, thermal plastic like phenolic resins, xylene resins, melamine resin, epoxy resin, alkyd resin and poly urethan resin, new plastic like ionomer and PPS resin, synthetic laminated tape and synthetic wood, mixed materials in plastic, reprocessing of waste plastic, polymer blend, test method for plastic materials and auxiliary materials of plastic.

  12. The management of cornea blindness from severe corneal scarring, with the Athens Protocol (transepithelial topography-guided PRK therapeutic remodeling, combined with same-day, collagen cross-linking

    Directory of Open Access Journals (Sweden)

    Kanellopoulos AJ

    2012-02-01

    Full Text Available Anastasios John KanellopoulosLaservision.gr Institute, Athens, Greece; Manhattan Eye, Ear and Throat Hospital, New York, NY, USA; New York University Medical School, New York, NY, USAPurpose: To evaluate the safety and efficacy of combined transepithelial topography-guided photorefractive keratectomy (PRK therapeutic remodeling, combined with same-day, collagen cross-linking (CXL. This protocol was used for the management of cornea blindness due to severe corneal scarring.Methods: A 57-year-old man had severe corneal blindness in both eyes. Both corneas had significant central scars attributed to a firework explosion 45 years ago, when the patient was 12 years old. Corrected distance visual acuity (CDVA was 20/100 both eyes (OU with refraction: +4.00, –4.50 at 135° in the right eye and +3.50, –1.00 at 55° in the left. Respective keratometries were: 42.3, 60.4 at 17° and 35.8, 39.1 at 151.3°. Cornea transplantation was the recommendation by multiple cornea specialists as the treatment of choice. We decided prior to considering a transplant to employ the Athens Protocol (combined topography-guided partial PRK and CXL in the right eye in February 2010 and in the left eye in September 2010. The treatment plan for both eyes was designed on the topography-guided wavelight excimer laser platform.Results: Fifteen months after the right eye treatment, the right cornea had improved translucency and was topographically stable with uncorrected distance visual acuity (UDVA 20/50 and CDVA 20/40 with refraction +0.50, –2.00 at 5°. We noted a similar outcome after similar treatment applied in the left eye with UDVA 20/50 and CDVA 20/40 with –0.50, –2.00 at 170° at the 8-month follow-up.Conclusion: In this case, the introduction of successful management of severe cornea abnormalities and scarring with the Athens Protocol may provide an effective alternative to other existing surgical or medical options.Keywords: Athens Protocol, collagen cross

  13. Pathogenic strains of Acanthamoeba are recognized by TLR4 and initiated inflammatory responses in the cornea.

    Directory of Open Access Journals (Sweden)

    Hassan Alizadeh

    Full Text Available Free-living amoebae of the Acanthamoeba species are the causative agent of Acanthamoeba keratitis (AK, a sight-threatening corneal infection that causes severe pain and a characteristic ring-shaped corneal infiltrate. Innate immune responses play an important role in resistance against AK. The aim of this study is to determine if Toll-like receptors (TLRs on corneal epithelial cells are activated by Acanthamoeba, leading to initiation of inflammatory responses in the cornea. Human corneal epithelial (HCE cells constitutively expressed TLR1, TLR2, TLR3, TLR4, and TLR9 mRNA, and A. castellanii upregulated TLR4 transcription. Expression of TLR1, TLR2, TLR3, and TLR9 was unchanged when HCE cells were exposed to A. castellanii. IL-8 mRNA expression was upregulated in HCE cells exposed to A. castellanii. A. castellanii and lipopolysaccharide (LPS induced significant IL-8 production by HCE cells as measured by ELISA. The percentage of total cells positive for TLR4 was higher in A. castellanii stimulated HCE cells compared to unstimulated HCE cells. A. castellanii induced upregulation of IL-8 in TLR4 expressing human embryonic kidney (HEK-293 cells, but not TLR3 expressing HEK-293 cells. TLR4 neutralizing antibody inhibited A. castellanii-induced IL-8 by HCE and HEK-293 cells. Clinical strains but not soil strains of Acanthamoeba activated TLR4 expression in Chinese hamster corneas in vivo and in vitro. Clinical isolates but not soil isolates of Acanthamoeba induced significant (P< 0.05 CXCL2 production in Chinese hamster corneas 3 and 7 days after infection, which coincided with increased inflammatory cells in the corneas. Results suggest that pathogenic species of Acanthamoeba activate TLR4 and induce production of CXCL2 in the Chinese hamster model of AK. TLR4 may be a potential target in the development of novel treatment strategies in Acanthamoeba and other microbial infections that activate TLR4 in corneal cells.

  14. GREEN PLASTIC: A NEW PLASTIC FOR PACKAGING

    OpenAIRE

    Mr. Pankaj Kumar*, Sonia

    2016-01-01

    This paper gives a brief idea about a new type of plastic called as bio-plastic or green plastic. Plastic is used as a packaging material for various products, but this plastic is made up of non renewable raw materials. There are various disadvantages of using conventional plastic like littering, CO2 production, non-degradable in nature etc. To overcome these problems a new type of plastic is discovered called bio-plastic or green plastic. Bio-plastic is made from renewable resources and also...

  15. Effect of irradiation and cystamine on the secondary induction of cornea in anura larvae

    International Nuclear Information System (INIS)

    Popov, D.V.; Starodubov, S.M.

    1977-01-01

    Secondary induction of cornea in the transplanted skin has been studied in amphibian larvae after the effect of irradiation and cystamine on the recipients and donors. Comparison of the results obtained with those reported earlier has demonstrated that the irradiated tissue is more responsive to inductive effects than the intact one

  16. Biofunctionalized Lysophosphatidic Acid/Silk Fibroin Film for Cornea Endothelial Cell Regeneration

    Science.gov (United States)

    Jeon, Hayan; Oliveira, Joaquim Miguel; Reis, Rui Luis; Khang, Gilson

    2018-01-01

    Cornea endothelial cells (CEnCs) tissue engineering is a great challenge to repair diseased or damaged CEnCs and require an appropriate biomaterial to support cell proliferation and differentiation. Biomaterials for CEnCs tissue engineering require biocompatibility, tunable biodegradability, transparency, and suitable mechanical properties. Silk fibroin-based film (SF) is known to meet these factors, but construction of functionalized graft for bioengineering of cornea is still a challenge. Herein, lysophosphatidic acid (LPA) is used to maintain and increase the specific function of CEnCs. The LPA and SF composite film (LPA/SF) was fabricated in this study. Mechanical properties and in vitro studies were performed using a rabbit model to demonstrate the characters of LPA/SF. ATR-FTIR was characterized to identify chemical composition of the films. The morphological and physical properties were performed by SEM, AFM, transparency, and contact angle. Initial cell density and MTT were performed for adhesion and cell viability in the SF and LPA/SF film. Reverse transcription polymerase chain reactions (RT-PCR) and immunofluorescence were performed to examine gene and protein expression. The results showed that films were designed appropriately for CEnCs delivery. Compared to pristine SF, LPA/SF showed higher biocompatibility, cell viability, and expression of CEnCs specific genes and proteins. These indicate that LPA/SF, a new biomaterial, offers potential benefits for CEnCs tissue engineering for regeneration. PMID:29710848

  17. Molecular Hydrogen Effectively Heals Alkali-Injured Cornea via Suppression of Oxidative Stress

    Czech Academy of Sciences Publication Activity Database

    Čejka, Čestmír; Kössl, Jan; Heřmánková, Barbora; Holáň, Vladimír; Čejková, Jitka

    2017-01-01

    Roč. 2017, č. 2017 (2017), s. 8906027 ISSN 1942-0900 R&D Projects: GA ČR(CZ) GA14-12580S; GA MŠk(CZ) ED1.1.00/02.0109; GA MŠk(CZ) LO1508; GA MŠk(CZ) LO1309 Institutional support: RVO:68378041 Keywords : 4-coumaric acid * rabbit cornea * nitric-oxide Subject RIV: FF - HEENT, Dentistry OBOR OECD: Ophthalmology Impact factor: 4.593, year: 2016

  18. The role of corneal endothelial morphology in graft assessment and prediction of endothelial cell loss during organ culture of human donor corneas.

    Science.gov (United States)

    Hermel, Martin; Salla, Sabine; Fuest, Matthias; Walter, Peter

    2017-03-01

    Endothelial assessment is crucial in the release of corneas for grafting. We retrospectively analysed the role of endothelial morphology parameters in predicting endothelial cell loss during organ culture. Human donor corneas were cultured in minimal essential medium with 2% fetal calf serum and antibiotics. Initial endothelial morphology was assessed microscopically using score parameters polymegethism (POL), pleomorphism (PLE), granulation (GRA), vacuolization (VAC), segmentation of cell membranes (SEG), Descemet's folds (DF), trypan blue-positive cells (TBPC) and endothelial cell-free areas (ECFA). Some corneas were primarily rejected based on endothelial assessment. Endothelial cell density (ECD) was assessed at the beginning (I-ECD) and end of culture. Corneas were then placed in dehydration medium (as above + 5% dextran 500). In a subgroup, ECD was reassessed after dehydration. Endothelial cell loss during culture (ECL@Culture) and culture+dehydration (ECL-Culture&Dehydration) were calculated. Data were given as mean ± SD and analysed using multiple linear and logistic regression. Odds ratios (OR) and 95% confidence intervals (CI) were calculated. I-ECD was 2812 ± 360/mm 2 (n = 2356). The decision to reject a cornea due to endothelial assessment was associated negatively with I-ECD (OR = 0.77/100 cells, CI 0.7-0.82) and positively with ECFA (OR = 2.7, CI 1.69-4.35), SEG (OR =1.3, CI 1.01-1.68) and donor age (OR = 1.26/decade, CI 1.33-1.41). ECL@Culture was 153 ± 201/mm 2 (n = 1277), ECL@Culture&Dehydration was 169 ± 183/mm 2 (n = 918). ECL@Culture was associated positively with donor age, I-ECD, GRA and TBPC, and negatively with PLE, and DF. ECL@Culture&Dehydration was associated positively with age, sex, initial ECD, POL, PLE, VAC and TBPC. Morphological parameters displayed associations with the exclusion of corneas from culture and with endothelial cell loss. Appropriate parameter selection for screening purposes may help improve

  19. The Resin-Embedded Cornea Prepared Via Rapid Processing Protocol : A Good Histomorphometric Target for Clinical Investigation in Ophthalmology and Optometry

    Science.gov (United States)

    Cheah, Pike See; Mohidin, Norhani; Mohd Ali, Bariah; Maung, Myint; Latif, Azian Abdul

    2008-01-01

    This study illustrates and quantifies the changes on corneal tissue between the paraffin-embedded and resin-embedded blocks and thus, selects a better target in investigational ophthalmology and optometry via light microscopy. Corneas of two cynomolgus monkeys (Macaca fascicularis) were used in this study. The formalin-fixed cornea was prepared in paraffin block via the conventional tissue processing protocol (4-day protocol) and stained with haematoxylin and eosin. The glutaraldehyde-fixed cornea was prepared in resin block via the rapid and modified tissue processing procedure (1.2-day protocol) and stained with toluidine blue. The paraffin-embedded sample exhibits various undesired tissue damage and artifact such as thinner epithelium (due to the substantial volumic extraction from the tissue), thicker stroma layer (due to the separation of lamellae and the presence of voids) and the distorted endothelium. In contrast, the resin-embedded corneal tissue has demonstrated satisfactory corneal ultrastructural preservation. The rapid and modified tissue processing method for preparing the resin-embedded is particularly beneficial to accelerate the microscopic evaluation in ophthalmology and optometry. PMID:22570589

  20. Mapping Rural Areas with Widespread Plastic Covered Vineyards Using True Color Aerial Data

    Directory of Open Access Journals (Sweden)

    Eufemia Tarantino

    2012-06-01

    Full Text Available Plastic covering is used worldwide to protect crops against damaging growing conditions. This agricultural practice raises some controversial issues. While it significantly impacts on local economic vitality, plasticulture also shows several environmental affects. In the Apulia Region (Italy the wide-spreading of artificial plastic coverings for vineyard protection has showed negative consequences on the hydrogeological balance of soils as well as on the visual quality of rural landscape. In order to monitor and manage this phenomenon, a detailed site mapping has become essential. In this study an efficient object-based classification procedure from Very High Spatial Resolution (VHSR true color aerial data was developed on eight test areas located in the Ionian area of the Apulia Region in order to support the updating of the existing land use database aimed at plastic covered vineyard monitoring.

  1. The comparative safety of genipin versus UVA-riboflavin crosslinking of rabbit corneas

    Science.gov (United States)

    Song, Wenjing; Tang, Yun; Qiao, Jing; Li, Haili; Rong, Bei; Yang, Songlin; Wu, Yuan

    2017-01-01

    Purpose To investigate, after 24 h, the safety of genipin or ultraviolet A (UVA)-riboflavin crosslinking of keratocytes and endothelial cells. Methods Fifteen New Zealand white rabbits were selected and divided into a PBS group (five rabbits), a 0.2% genipin crosslinking (GP-CXL) group (five rabbits), and a UVA-riboflavin crosslinking (UVA-CXL) group (five rabbits). In the GP-CXL and PBS groups, 0.2% genipin or PBS was applied to the corneal surface of the right eyes. In the UVA-CXL group, a clinical crosslinking procedure was used. Before and after surgery, the operated eyes of each group were characterized with confocal microscopy, and the corneal buttons were excised for endothelium staining and electron microscopy. Results The corneal endothelial cell density of the GP-CXL, UVA-CLX, and PBS groups changed. There was a statistically significant difference in thickness and changes in corneal endothelial cell density between the UVA-CXL group and the PBS group (pUVA-CXL group and the GP-CXL group (pUVA-CXL group. In the GP-CXL group, only active keratocytes were found and minimal endothelial cell damage. Conclusions Treatment of rabbit corneas with 0.2% genipin showed minimal toxicity toward keratocytes and endothelial cells. Genipin is safer than UVA-CXL for crosslinking of thin corneas. PMID:28761323

  2. Semen preservation and artificial insemination in domesticated South American camelids.

    Science.gov (United States)

    Bravo, P Walter; Alarcon, V; Baca, L; Cuba, Y; Ordoñez, C; Salinas, J; Tito, F

    2013-01-10

    Semen preservation and artificial insemination in South American camelids are reviewed giving emphasis to work done in Peru and by the authors. Reports on semen evaluation and the preservation process indicate that semen of alpacas and llamas can be manipulated by making it liquid first. Collagenase appears to be the best enzyme to eliminate viscosity. Tris buffer solution maintains a higher motility than egg-yolk citrate, phosphate buffered saline (PBS), Triladyl, and Merck-I extenders. Cooling of semen took 1h after collected, and equilibrated with 7% glycerol presented a better motility and spermatozoa survival at 1, 7, 15 and 30days after being slowly frozen in 0.25mL plastic straws. Trials of artificial insemination with freshly diluted semen and frozen-thawed semen are encouraging and needs to be tested extensively under field conditions. Recently, fertility rates varied from 3 to 67%. Semen preservation and most important, artificial insemination appear to be a reality, and could be used to improve the genetic quality of alpacas and llamas. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Collagen cross-linking in thin corneas

    Directory of Open Access Journals (Sweden)

    Prema Padmanabhan

    2013-01-01

    Full Text Available Collagen cross-linking (CXL has become the standard of care for progressive keratoconus, after numerous clinical studies have established its efficacy and safety in suitably selected eyes. The standard protocol is applicable in eyes which have a minimum corneal thickness of 400 μm after epithelial debridement. This prerequisite was stipulated to protect the corneal endothelium and intraocular tissues from the deleterious effect of ultraviolet-A (UVA radiation. However, patients with keratoconus often present with corneal thickness of less than 400 μm and could have otherwise benefited from this procedure. A few modifications of the standard procedure have been suggested to benefit these patients without a compromise in safety. Transepithelial cross-linking, pachymetry-guided epithelial debridement before cross-linking, and the use of hypoosmolar riboflavin are some of the techniques that have been attempted. Although clinical data is limited at the present time, these techniques are worth considering in patients with thin corneas. Further studies are needed to scientifically establish their efficacy and safety.

  4. Proliferative activity of endotheliocytes of growing capillaries of the rabbit cornea

    International Nuclear Information System (INIS)

    Gurina, O.Yu.; Mamontov, S.G.; Banin, V.V.

    1987-01-01

    The authors studied the intensity of DNA synthesis by cells of newly formed capillaries, growing in the rabbit cornea, after infliction of a silver nitrate burn and local application of colchicine. The intensity of capillary growth was investigated during stimulation and a combination of the burn with colchicine. Changes in activity of DNA synthesis by the endotheliocytes of newly formed capillaries during exposure throughout growth were also investigated. The intensity of cell proliferation was studied by measuring the incorporation of tritium-labelled thymidine into the endotheoiocyte nuclei

  5. The management of cornea blindness from severe corneal scarring, with the Athens Protocol (transepithelial topography-guided PRK therapeutic remodeling, combined with same-day, collagen cross-linking).

    Science.gov (United States)

    Kanellopoulos, Anastasios John

    2012-01-01

    To evaluate the safety and efficacy of combined transepithelial topography-guided photorefractive keratectomy (PRK) therapeutic remodeling, combined with same-day, collagen cross-linking (CXL). This protocol was used for the management of cornea blindness due to severe corneal scarring. A 57-year-old man had severe corneal blindness in both eyes. Both corneas had significant central scars attributed to a firework explosion 45 years ago, when the patient was 12 years old. Corrected distance visual acuity (CDVA) was 20/100 both eyes (OU) with refraction: +4.00, -4.50 at 135° in the right eye and +3.50, -1.00 at 55° in the left. Respective keratometries were: 42.3, 60.4 at 17° and 35.8, 39.1 at 151.3°. Cornea transplantation was the recommendation by multiple cornea specialists as the treatment of choice. We decided prior to considering a transplant to employ the Athens Protocol (combined topography-guided partial PRK and CXL) in the right eye in February 2010 and in the left eye in September 2010. The treatment plan for both eyes was designed on the topography-guided wavelight excimer laser platform. Fifteen months after the right eye treatment, the right cornea had improved translucency and was topographically stable with uncorrected distance visual acuity (UDVA) 20/50 and CDVA 20/40 with refraction +0.50, -2.00 at 5°. We noted a similar outcome after similar treatment applied in the left eye with UDVA 20/50 and CDVA 20/40 with -0.50, -2.00 at 170° at the 8-month follow-up. In this case, the introduction of successful management of severe cornea abnormalities and scarring with the Athens Protocol may provide an effective alternative to other existing surgical or medical options.

  6. Towards a Scalable, Biomimetic, Antibacterial Coating

    Science.gov (United States)

    Dickson, Mary Nora

    Corneal afflictions are the second leading cause of blindness worldwide. When a corneal transplant is unavailable or contraindicated, an artificial cornea device is the only chance to save sight. Bacterial or fungal biofilm build up on artificial cornea devices can lead to serious complications including the need for systemic antibiotic treatment and even explantation. As a result, much emphasis has been placed on anti-adhesion chemical coatings and antibiotic leeching coatings. These methods are not long-lasting, and microorganisms can eventually circumvent these measures. Thus, I have developed a surface topographical antimicrobial coating. Various surface structures including rough surfaces, superhydrophobic surfaces, and the natural surfaces of insects' wings and sharks' skin are promising anti-biofilm candidates, however none meet the criteria necessary for implementation on the surface of an artificial cornea device. In this thesis I: 1) developed scalable fabrication protocols for a library of biomimetic nanostructure polymer surfaces 2) assessed the potential these for poly(methyl methacrylate) nanopillars to kill or prevent formation of biofilm by E. coli bacteria and species of Pseudomonas and Staphylococcus bacteria and improved upon a proposed mechanism for the rupture of Gram-negative bacterial cell walls 3) developed a scalable, commercially viable method for producing antibacterial nanopillars on a curved, PMMA artificial cornea device and 4) developed scalable fabrication protocols for implantation of antibacterial nanopatterned surfaces on the surfaces of thermoplastic polyurethane materials, commonly used in catheter tubings. This project constitutes a first step towards fabrication of the first entirely PMMA artificial cornea device. The major finding of this work is that by precisely controlling the topography of a polymer surface at the nano-scale, we can kill adherent bacteria and prevent biofilm formation of certain pathogenic bacteria

  7. Corneal thickness changes during corneal collagen cross-linking with UV-A irradiation and hypo-osmolar riboflavin in thin corneas

    Directory of Open Access Journals (Sweden)

    Belquiz Amaral Nassaralla

    2013-06-01

    Full Text Available PURPOSE: To evaluate the thinnest corneal thickness changes during and after corneal collagen cross-linking treatment with ultraviolet-A irradiation, using hypo-osmolar riboflavin solution in thin corneas. METHODS: Eighteen eyes of 18 patients were included in this study. After epithelium removal, iso-osmolar 0.1% riboflavin solution was instilled to the cornea every 3 minutes for 30 minutes. Hypo-osmolar 0.1% riboflavin solution was then applied every 20 seconds for 5 minutes or until the thinnest corneal thickness reached 400 µm. Ultraviolet-A irradiation was performed for 30 minutes. During irradiation, iso-osmolar 0.1% riboflavin drops were applied every 5 minutes. Ultrasound pachymetry was performed at approximately the thinnest point of the cornea preoperatively, after epithelial removal, after iso-osmolar riboflavin instillation, after hypo-osmolar riboflavin instillation, after ultraviolet-A irradiation, and at 1, 6 and 12 months after treatment. RESULTS: Mean preoperative thinnest corneal thickness was 380 ± 11 µm. After epithelial removal it decreased to 341 ± 11 µm, and after 30 minutes of iso-osmolar 0.1% riboflavin drops, to 330 ± 7.6 µm. After hypo-osmolar 0.1% riboflavin drops, mean thinnest corneal thickness increased to 418 ± 11 µm. After UVA irradiation, it was 384 ± 10 µm. At 1, 6 and 12 months after treatment, it was 372 ± 10 µm, 381 ± 12.7, and 379 ± 15 µm, respectively. No intraoperative, early postoperative, or late postoperative complications were noted. CONCLUSIONS: Hypo-osmolar 0.1% riboflavin solution seems to be effective for swelling thin corneas. The swelling effect is transient and short acting. Corneal thickness should be monitored throughout the procedure. Larger sample sizes and longer follow-up are required in order to make meaningful conclusions regarding safety.

  8. Distribution of Young's modulus in porcine corneas after riboflavin/UVA-induced collagen cross-linking as measured by atomic force microscopy.

    Directory of Open Access Journals (Sweden)

    Jan Seifert

    Full Text Available Riboflavin/UVA-induced corneal collagen cross-linking has become an effective clinical application to treat keratoconus and other ectatic disorders of the cornea. Its beneficial effects are attributed to a marked stiffening of the unphysiologically weak stroma. Previous studies located the stiffening effect predominantly within the anterior cornea. In this study, we present an atomic force microscopy-derived analysis of the depth-dependent distribution of the Young's modulus with a depth resolution of 5 µm in 8 cross-linked porcine corneas and 8 contralateral controls. Sagittal cryosections were fabricated from every specimen and subjected to force mapping. The mean stromal depth of the zone with effective cross-linking was found to be 219 ± 67 µm. Within this cross-linked zone, the mean Young's modulus declined from 49 ± 18 kPa at the corneal surface to 46 ± 17 kPa, 33 ± 11 kPa, 17 ± 5 kPa, 10 ± 4 kPa and 10 ± 4 kPa at stromal depth intervals of 0-50 µm, 50-100 µm, 100-150 µm, 150-200 µm and 200-250 µm, respectively. This corresponded to a stiffening by a factor of 8.1 (corneal surface, 7.6 (0-50 µm, 5.4 (50-100 µm, 3.0 (100-150 µm, 1.6 (150-200 µm, and 1.5 (200-250 µm, when compared to the Young's modulus of the posterior 100 µm. The mean Young's modulus within the cross-linked zone was 20 ± 8 kPa (2.9-fold stiffening, while it was 11 ± 4 kPa (1.7-fold stiffening for the entire stroma. Both values were significantly distinct from the mean Young's modulus obtained from the posterior 100 µm of the cross-linked corneas and from the contralateral controls. In conclusion, we were able to specify the depth-dependent distribution of the stiffening effect elicited by standard collagen cross-linking in porcine corneas. Apart from determining the depth of the zone with effective corneal cross-linking, we also developed a method that allows for atomic force microscopy-based measurements of gradients of Young's modulus in soft

  9. Nanotechnology and regenerative therapeutics in plastic surgery: The next frontier.

    Science.gov (United States)

    Tan, Aaron; Chawla, Reema; G, Natasha; Mahdibeiraghdar, Sara; Jeyaraj, Rebecca; Rajadas, Jayakumar; Hamblin, Michael R; Seifalian, Alexander M

    2016-01-01

    The rapid ascent of nanotechnology and regenerative therapeutics as applied to medicine and surgery has seen an exponential rise in the scale of research generated in this field. This is evidenced not only by the sheer volume of papers dedicated to nanotechnology but also in a large number of new journals dedicated to nanotechnology and regenerative therapeutics specifically to medicine and surgery. Aspects of nanotechnology that have already brought benefits to these areas include advanced drug delivery platforms, molecular imaging and materials engineering for surgical implants. Particular areas of interest include nerve regeneration, burns and wound care, artificial skin with nanoelectronic sensors and head and neck surgery. This study presents a review of nanotechnology and regenerative therapeutics, with focus on its applications and implications in plastic surgery. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. All rights reserved.

  10. Soil architecture relationships with dynamic soil physical processes: a conceptual study using natural, artificial, and 3D-printed soil cores

    DEFF Research Database (Denmark)

    Lamandé, Mathieu; Schjønning, Per; Dal Ferro, Nicola

    Pore system architecture is a key feature for understanding physical, biological and chemical processes in soils. Development of visualisation technics, especially x-ray CT, during recent years has been useful in describing the complex relationships between soil architecture and soil functions. We...... believe that combining visualization with physical models is a step further towards a better understanding of these relationships. We conducted a concept study using natural, artificial and 3D-printed soil cores. Eight natural soil cores (100 cm3) were sampled in a cultivated stagnic Luvisol at two depths...... (topsoil and subsoil), representing contrasting soil pore systems. Cylinders (100 cm3) were produced from plastic or from autoclaved aerated concrete. Holes of diameters 1.5 and 3 mm were drilled in the cylinder direction for the plastic cylinder and for one of the AAC cylinders. All natural and artificial...

  11. The effect of radiation and cystamine on the ability of the eye to induce the cornea in the intact skin

    International Nuclear Information System (INIS)

    Popov, D.V.; Starodubov, S.M.

    1975-01-01

    Common frog tadpoles (with and without cystamine protection) were subjected to whole-body irradiation (700 R) and skin transplanted from the back of donors to the site of the outer cornea of the right eye of the recipients. Secondary cornea induction in non-irradiated skin transplanted to the eye was then studied. It was found that a dose of 700 R completely suppresses the induction capacity of the eye, while cystamine protects it to 47.8%. It was also shown that the irradiation of tadpoles with X-rays slows down their general development, but that, with cystamine protection, their development rate remains normal. (V.A.P.)

  12. Xanthelasma Palpebrarum with Arcus Cornea: A Clinical and Biochemical Study.

    Science.gov (United States)

    Nair, Pragya Ashok; Patel, Chaitali R; Ganjiwale, Jaishree D; Diwan, Nilofar Gulamsha; Jivani, Nidhi Bhimjibhai

    2016-01-01

    Xanthelasma palpebrarum (XP) is characterized by sharply demarcated yellowish flat plaques on upper and lower eyelids. It is commonly seen in women with a peak incidence at 30-50 years. It is also considered as the cutaneous marker of underlying atherosclerosis along with the disturbed lipid metabolism. XP and corneal arcus are associated with increased levels of serum cholesterol and low-density lipoprotein (LDL) cholesterol. To study the clinical pattern of XP, its relationship with lipid profile and association with arcus cornea. This study was conducted at Department of Dermatology and Opthalmology, between August 2013 and January 2015. Patients with clinical diagnosis of XP who visited skin outpatient department and willing to undergo lipid profile test and eye examination were included in the study. Data regarding demographics, clinical findings, family history, and past history were noted along with the lipid profile details. Data of age-matched healthy controls were taken for comparison. The clinical profile of the participants was presented using frequency and proportions. Gender wise analysis comparing the lipid profile in cases with XP and without XP was done using independent sample t-test. Total 49 patients of XP, 81.6% were females. Maximum, 35% patients were among 50-60 years of age and 69.4% were homemakers by occupation. The average lipid values were-cholesterol 210.57 mg%, triglyceride 123.06 mg%. LDL 142.79 mg% and VLDL 30.95 mg% among patients of XP. Arcus cornea was found in 20% cases of XP. Patients of XP requires proper investigation at the onset and regular follow-up thereafter for any altered lipid profile and early diagnosis of coronary artery disease.

  13. Topical timolol with and without benzalkonium chloride: epithelial permeability and autofluorescence of the cornea in glaucoma.

    Science.gov (United States)

    de Jong, C; Stolwijk, T; Kuppens, E; de Keizer, R; van Best, J

    1994-04-01

    Epithelial permeability and autofluorescence of the cornea were determined by fluorophotometry in 21 patients with open-angle glaucoma or ocular hypertension using timolol medication with the preservative benzalkonium chloride (BAC) and 2 weeks after changing to timolol medication without BAC. The investigation was performed to determine whether removal of BAC would reduce toxic effects on the cornea and complaints of sensations of burning or dry eye. Corneal epithelial permeability decreased significantly after changing medication (mean decrease per patient 27%, P = 0.025). Corneal autofluorescence increased significantly after changing medication suggesting an alteration in corneal metabolism (mean increase per patient 6%, P = 0.003). Timolol without BAC was found to be as effective as timolol with BAC in reducing intraocular pressure (P = 0.4). Removal of BAC from timolol resulted in an improvement of corneal epithelial barrier function and in a reduction of complaints. The improvement was found to be proportional to the duration of the preceding BAC-containing therapy.

  14. Femtosecond lasers for microsurgery of cornea

    International Nuclear Information System (INIS)

    Vartapetov, Sergei K; Khudyakov, D V; Lapshin, Konstantin E; Obidin, Aleksei Z; Shcherbakov, Ivan A

    2012-01-01

    The review of femtosecond laser installations for medical applications is given and a new femtosecond ophthalmologic system for creation of a flap of corneal tissue during the LASIK operation is described. An all-fibre femtosecond laser emitting ∼400-fs pulses at 1067 nm is used. The pulse repetition rate can vary from 200 kHz up to 1 MHz. The output energy of the femtosecond system does not exceed 1 μJ. A specially developed objective with small spherical and chromatic aberrations is applied to focus laser radiation to an area of an eye cornea. The size of the focusing spot does not exceed 3 μm. To process the required area, scanning by a laser beam is applied with a speed no less than 5 m s -1 . At a stage of preliminary tests of the system, the Κ8 glass, organic PMMA glass and specially prepared agarose gels are used as a phantom of an eye. The femtosecond system is successfully clinically tested on a plenty of eyes of a pig and on several human eyes. The duration of the procedure of creation of a corneal flap does not exceed 20 s.

  15. Femtosecond lasers for microsurgery of cornea

    Energy Technology Data Exchange (ETDEWEB)

    Vartapetov, Sergei K; Khudyakov, D V; Lapshin, Konstantin E; Obidin, Aleksei Z; Shcherbakov, Ivan A

    2012-03-31

    The review of femtosecond laser installations for medical applications is given and a new femtosecond ophthalmologic system for creation of a flap of corneal tissue during the LASIK operation is described. An all-fibre femtosecond laser emitting {approx}400-fs pulses at 1067 nm is used. The pulse repetition rate can vary from 200 kHz up to 1 MHz. The output energy of the femtosecond system does not exceed 1 {mu}J. A specially developed objective with small spherical and chromatic aberrations is applied to focus laser radiation to an area of an eye cornea. The size of the focusing spot does not exceed 3 {mu}m. To process the required area, scanning by a laser beam is applied with a speed no less than 5 m s{sup -1}. At a stage of preliminary tests of the system, the {Kappa}8 glass, organic PMMA glass and specially prepared agarose gels are used as a phantom of an eye. The femtosecond system is successfully clinically tested on a plenty of eyes of a pig and on several human eyes. The duration of the procedure of creation of a corneal flap does not exceed 20 s.

  16. Establishment of a new in vitro test method for evaluation of eye irritancy using a reconstructed human corneal epithelial model, LabCyte CORNEA-MODEL.

    Science.gov (United States)

    Katoh, Masakazu; Hamajima, Fumiyasu; Ogasawara, Takahiro; Hata, Ken-ichiro

    2013-12-01

    Finding in vitro eye irritation testing alternatives to animal testing such as the Draize eye test, which uses rabbits, is essential from the standpoint of animal welfare. It has been developed a reconstructed human corneal epithelial model, the LabCyte CORNEA-MODEL, which has a representative corneal epithelium-like structure. Protocol optimization (pre-validation study) was examined in order to establish a new alternative method for eye irritancy evaluation with this model. From the results of the optimization experiments, the application periods for chemicals were set at 1min for liquid chemicals or 24h for solid chemicals, and the post-exposure incubation periods were set at 24h for liquids or zero for solids. If the viability was less than 50%, the chemical was judged to be an eye irritant. Sixty-one chemicals were applied in the optimized protocol using the LabCyte CORNEA-MODEL and these results were evaluated in correlation with in vivo results. The predictions of the optimized LabCyte CORNEA-MODEL eye irritation test methods were highly correlated with in vivo eye irritation (sensitivity 100%, specificity 80.0%, and accuracy 91.8%). These results suggest that the LabCyte CORNEA-MODEL eye irritation test could be useful as an alternative method to the Draize eye test. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Artificial Consciousness or Artificial Intelligence

    OpenAIRE

    Spanache Florin

    2017-01-01

    Artificial intelligence is a tool designed by people for the gratification of their own creative ego, so we can not confuse conscience with intelligence and not even intelligence in its human representation with conscience. They are all different concepts and they have different uses. Philosophically, there are differences between autonomous people and automatic artificial intelligence. This is the difference between intelligence and artificial intelligence, autonomous versus a...

  18. Xanthelasma palpebrarum with arcus cornea: A clinical and biochemical study

    Directory of Open Access Journals (Sweden)

    Pragya Ashok Nair

    2016-01-01

    Full Text Available Background: Xanthelasma palpebrarum (XP is characterized by sharply demarcated yellowish flat plaques on upper and lower eyelids. It is commonly seen in women with a peak incidence at 30–50 years. It is also considered as the cutaneous marker of underlying atherosclerosis along with the disturbed lipid metabolism. XP and corneal arcus are associated with increased levels of serum cholesterol and low-density lipoprotein (LDL cholesterol. Aims and Objectives: To study the clinical pattern of XP, its relationship with lipid profile and association with arcus cornea. Materials and Methods: This study was conducted at Department of Dermatology and Opthalmology, between August 2013 and January 2015. Patients with clinical diagnosis of XP who visited skin outpatient department and willing to undergo lipid profile test and eye examination were included in the study. Data regarding demographics, clinical findings, family history, and past history were noted along with the lipid profile details. Data of age-matched healthy controls were taken for comparison. The clinical profile of the participants was presented using frequency and proportions. Gender wise analysis comparing the lipid profile in cases with XP and without XP was done using independent sample t-test. Results: Total 49 patients of XP, 81.6% were females. Maximum, 35% patients were among 50–60 years of age and 69.4% were homemakers by occupation. The average lipid values were-cholesterol 210.57 mg%, triglyceride 123.06 mg%. LDL 142.79 mg% and VLDL 30.95 mg% among patients of XP. Arcus cornea was found in 20% cases of XP. Conclusions: Patients of XP requires proper investigation at the onset and regular follow-up thereafter for any altered lipid profile and early diagnosis of coronary artery disease.

  19. Partial Denervation of Subbasal Axons Persists Following Debridement Wounds to the Mouse Cornea

    Science.gov (United States)

    Pajoohesh-Ganji, Ahdeah; Pal-Ghosh, Sonali; Tadvalkar, Gauri; Kyne, Briana M.; Saban, Daniel R.; Stepp, Mary Ann

    2015-01-01

    Although sensory reinnervation occurs after injury in the PNS, poor reinnervation in the elderly and those with diabetes often leads to pathology. Here we quantify subbasal axon density in the central and peripheral mouse cornea over time after three different types of injury. The mouse cornea is highly innervated with a dense array of subbasal nerves that form a spiral called the vortex at the corneal center or apex; these nerves are readily detected within flat mounted corneas. After anesthesia, corneal epithelial cells were removed using either a dulled blade or a rotating burr within an area demarcated centrally with a 1.5 mm trephine. A third wound type, superficial trephination, involved demarcating the area with the 1.5 mm trephine but not removing cells. By 7d after superficial trephination, subbasal axon density returns to control levels; by 28d the vortex reforms. Although axon density is similar to control 14d after dulled blade and rotating burr wounding, defects in axon morphology at the corneal apex remain. After 14d, axons retract from the center leaving the subbasal axon density reduced by 37.2% and 36.8% at 28d after dulled blade and rotating burr wounding, respectively, compared to control. Assessment of inflammation using flow cytometry shows that persistent inflammation is not a factor in the incomplete reinnervation. Expression of mRNAs encoding 22 regeneration associated genes (RAGs) involved in axon targeting assessed by QPCR reveals that netrin-1 and ephrin signaling are altered after wounding. Subpopulations of corneal epithelial basal cells at the corneal apex stop expressing ki67 as early as 7d after injury and by 14d and 28d after wounding, many of these basal cells undergo apoptosis and die. While subbasal axons are restored to their normal density and morphology after superficial trephination, subbasal axon recovery is partial after debridement wounds. The increase in corneal epithelial basal cell apoptosis at the apex observed at 14d

  20. Oxidative Stress to the Cornea, Changes in Corneal Optical Properties, and Advances in Treatment of Corneal Oxidative Injuries

    Directory of Open Access Journals (Sweden)

    Cestmir Cejka

    2015-01-01

    Full Text Available Oxidative stress is involved in many ocular diseases and injuries. The imbalance between oxidants and antioxidants in favour of oxidants (oxidative stress leads to the damage and may be highly involved in ocular aging processes. The anterior eye segment and mainly the cornea are directly exposed to noxae of external environment, such as air pollution, radiation, cigarette smoke, vapors or gases from household cleaning products, chemical burns from splashes of industrial chemicals, and danger from potential oxidative damage evoked by them. Oxidative stress may initiate or develop ocular injury resulting in decreased visual acuity or even vision loss. The role of oxidative stress in the pathogenesis of ocular diseases with particular attention to oxidative stress in the cornea and changes in corneal optical properties are discussed. Advances in the treatment of corneal oxidative injuries or diseases are shown.

  1. Penetration of 45Ca in rabbit cornea following the introduction of air in the anterior chamber and its paracenthesis and following experimental intraocular hypertension

    International Nuclear Information System (INIS)

    Votockova, J.; Obenberger, J.; Babicky, A.

    1977-01-01

    In one group of Chinchilla rabbits the aqueous humor was withdrawn and the anterior chamber was refilled with air; in a second group only simple paracenthesis and withdrawal were performed; in a third group of animals experimental intraocular hypertension was produced by means of a subconjunctival injection of hypertonic sodium chloride. Immediately after these operations, a solution of 45 CaCl 2 was intravenously injected, and the rabbits were sacrificed after an interval of 30 min or 120 min. The corneas were excised and the radioactivity in central parts (trephined discs of 8 mm in diameter) and in remaining peripheral parts was determined. In all groups the corneal radioactivity in operated eyes exceeded the values found in the contralateral corneas of not operated eyes, radioactivity in these eyes being equal to the radioactivity found in the corneas of not operated rabbits in the control group. Various possible explanations of the increase of corneal radioactivity in operated eyes are briefly discussed. (author)

  2. Effect of a pulsed magnetic field on permeability of the cornea and sorption properties of the tissue structures and refractive media of the eye

    International Nuclear Information System (INIS)

    Skrinnik, A.V.

    1986-01-01

    The author attempts to obtain direct proof of increased permeability of the cornea and enhanced sorption properties of the tissue structures and refractive media of the eye under the influence of a pulsed magnetic field (MF). In the course of the investigation, the method of radioactive indication of two substances ( 35 S-streptomycin and 75 Se-methionine), widely used in opthalmologic practice, was used. The radioactivity of the working solution of the preparations was 300,000 cpm in 0.1 ml. Changes in the permeability of the cornea were assessed on the basis of changes in radioactivity of the aqueous humor. The concentration of 35 S-streptomycin in aqueous humor of the animals immediately after exposure to MF was significantly higher than in the control. Analysis of permeability of the cornea for 75 Se-methionine also showed increased penetration of radioactivity into the aqueous. The results are evidence of the greater penetrating power of 75 Se-methionine

  3. Experience of Comamonas Acidovorans Keratitis with Delayed Onset and Treatment Response in Immunocompromised Cornea

    OpenAIRE

    Lee, Sang Mok; Kim, Mee Kum; Lee, Jae Lim; Wee, Won Ryang; Lee, Jin Hak

    2008-01-01

    Purpose To report 2 cases of Comamonas Acidovorans keratitis in immunocompromised cornea. Methods A complete review of the medical records of the two cases of Comamonas acidovorans keratitis. Results We found some similarities in clinical courses of two cases. Both of them showed development of keratitis during the management with corticosteroids, delayed onset, slow response to antibiotics, and relatively less affected corneal epithelium. Conclusions Comamonas Acidovorans is known as a less ...

  4. Artificial Microstructures to Investigate Microstructure-Property Relationships in Metallic Glasses

    Science.gov (United States)

    Sarac, Baran

    Technology has evolved rapidly within the last decade, and the demand for higher performance materials has risen exponentially. To meet this demand, novel materials with advanced microstructures have been developed and are currently in use. However, the already complex microstructure of technological relevant materials imposes a limit for currently used development strategies for materials with optimized properties. For this reason, a strategy to correlate microstructure features with properties is still lacking. Computer simulations are challenged due to the computing size required to analyze multi-scale characteristics of complex materials, which is orders of magnitude higher than today's state of the art. To address these challenges, we introduced a novel strategy to investigate microstructure-property relationships. We call this strategy "artificial microstructure approach", which allows us to individually and independently control microstructural features. By this approach, we defined a new way of analyzing complex microstructures, where microstructural second phase features were precisely varied over a wide range. The artificial microstructures were fabricated by the combination of lithography and thermoplastic forming (TPF), and subsequently characterized under different loading conditions. Because of the suitability and interesting properties of metallic glasses, we proposed to use this toolbox to investigate the different deformation modes in cellular structures and toughening mechanism in metallic glass (MG) composites. This study helped us understand how to combine the unique properties of metallic glasses such as high strength, elasticity, and thermoplastic processing ability with plasticity generated from heterostructures of metallic glasses. It has been widely accepted that metallic glass composites are very complex, and a broad range of contributions have been suggested to explain the toughening mechanism. This includes the shear modulus, morphology

  5. Defective cerebellar control of cortical plasticity in writer’s cramp

    Science.gov (United States)

    Hubsch, Cecile; Roze, Emmanuel; Popa, Traian; Russo, Margherita; Balachandran, Ammu; Pradeep, Salini; Mueller, Florian; Brochard, Vanessa; Quartarone, Angelo; Degos, Bertrand; Vidailhet, Marie; Kishore, Asha

    2013-01-01

    A large body of evidence points to a role of basal ganglia dysfunction in the pathophysiology of dystonia, but recent studies indicate that cerebellar dysfunction may also be involved. The cerebellum influences sensorimotor adaptation by modulating sensorimotor plasticity of the primary motor cortex. Motor cortex sensorimotor plasticity is maladaptive in patients with writer’s cramp. Here we examined whether putative cerebellar dysfunction in dystonia is linked to these patients’ maladaptive plasticity. To that end we compared the performances of patients and healthy control subjects in a reaching task involving a visuomotor conflict generated by imposing a random deviation (−40° to 40°) on the direction of movement of the mouse/cursor. Such a task is known to involve the cerebellum. We also compared, between patients and healthy control subjects, how the cerebellum modulates the extent and duration of an ongoing sensorimotor plasticity in the motor cortex. The cerebellar cortex was excited or inhibited by means of repeated transcranial magnetic stimulation before artificial sensorimotor plasticity was induced in the motor cortex by paired associative stimulation. Patients with writer’s cramp were slower than the healthy control subjects to reach the target and, after having repeatedly adapted their trajectories to the deviations, they were less efficient than the healthy control subjects to perform reaching movement without imposed deviation. It was interpreted as impaired washing-out abilities. In healthy subjects, cerebellar cortex excitation prevented the paired associative stimulation to induce a sensorimotor plasticity in the primary motor cortex, whereas cerebellar cortex inhibition led the paired associative stimulation to be more efficient in inducing the plasticity. In patients with writer’s cramp, cerebellar cortex excitation and inhibition were both ineffective in modulating sensorimotor plasticity. In patients with writer’s cramp, but not

  6. Plasticity theory

    CERN Document Server

    Lubliner, Jacob

    2008-01-01

    The aim of Plasticity Theory is to provide a comprehensive introduction to the contemporary state of knowledge in basic plasticity theory and to its applications. It treats several areas not commonly found between the covers of a single book: the physics of plasticity, constitutive theory, dynamic plasticity, large-deformation plasticity, and numerical methods, in addition to a representative survey of problems treated by classical methods, such as elastic-plastic problems, plane plastic flow, and limit analysis; the problem discussed come from areas of interest to mechanical, structural, and

  7. Effect of biometric characteristics on biomechanical properties of the cornea in cataract patient.

    Science.gov (United States)

    Song, Xue-Fei; Langenbucher, Achim; Gatzioufas, Zisis; Seitz, Berthold; El-Husseiny, Moatasem

    2016-01-01

    To determine the impact of biometric characteristics on the biomechanical properties of the human cornea using the ocular response analyzer (ORA) and standard comprehensive ophthalmic examinations before and after standard phacoemulsification. This study comprised 54 eyes with cataract with significant lens opacification in stages I or II that underwent phacoemulsification (2.8 mm incision). Corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg), and corneal-compensated intraocular pressure (IOPcc) were measured by ORA preoperatively and at 1mo postoperatively. Biometric characteristics were derived from corneal topography [TMS-5, anterior equivalent (EQTMS) and cylindric (CYLTMS) power], corneal tomography [Casia, anterior and posterior equivalent (EQaCASIC, EQpCASIA) and cylindric (CYLaCASIA, CYLpCASIA) power], keratometry [IOLMaster, anterior equivalent (EQIOL) and cylindric (CYLIOL) power] and autorefractor [anterior equivalent (EQAR)]. Results from ORA were analyzed and correlated with those from all other examinations taken at the same time point. Preoperatively, CH correlated with EQpCASIA and CYLpCASIA only (P=0.001, P=0.002). Postoperatively, IOPg and IOPcc correlated with all equivalent powers (EQTMS, EQIOL, EQAR, EQaCASIA and EQpCASIA) (P=0.001, P=0.007, P=0.001, P=0.015, P=0.03 for IOPg and PBiometric characteristics may significantly affect biomechanical properties of the cornea in terms of CH, IOPcc and IOPg before, but even more after cataract surgery.

  8. Long-Term Synaptic Plasticity Emulated in Modified Graphene Oxide Electrolyte Gated IZO-Based Thin-Film Transistors.

    Science.gov (United States)

    Yang, Yi; Wen, Juan; Guo, Liqiang; Wan, Xiang; Du, Peifu; Feng, Ping; Shi, Yi; Wan, Qing

    2016-11-09

    Emulating neural behaviors at the synaptic level is of great significance for building neuromorphic computational systems and realizing artificial intelligence. Here, oxide-based electric double-layer (EDL) thin-film transistors were fabricated using 3-triethoxysilylpropylamine modified graphene oxide (KH550-GO) electrolyte as the gate dielectrics. Resulting from the EDL effect and electrochemical doping between mobile protons and the indium-zinc-oxide channel layer, long-term synaptic plasticity was emulated in our devices. Synaptic functions including long-term memory, synaptic temporal integration, and dynamic filters were successfully reproduced. In particular, spike rate-dependent plasticity (SRDP), one of the basic learning rules of long-term plasticity in the neural network where the synaptic weight changes according to the rate of presynaptic spikes, was emulated in our devices. Our results may facilitate the development of neuromorphic computational systems.

  9. Natural - synthetic - artificial!

    DEFF Research Database (Denmark)

    Nielsen, Peter E

    2010-01-01

    The terms "natural," "synthetic" and "artificial" are discussed in relation to synthetic and artificial chromosomes and genomes, synthetic and artificial cells and artificial life.......The terms "natural," "synthetic" and "artificial" are discussed in relation to synthetic and artificial chromosomes and genomes, synthetic and artificial cells and artificial life....

  10. Corneal NF-kappaB activity is necessary for the retention of transparency in the cornea of UV-B-exposed transgenic reporter mice.

    Science.gov (United States)

    Alexander, George; Carlsen, Harald; Blomhoff, Rune

    2006-04-01

    To determine the dynamics of Nuclear Factor-kappaB (NF-kappaB) in murine corneal pathology and the role of NF-kappaB in maintaining corneal clarity after ultraviolet B radiation insult, transgenic mice containing NF-kappaB-luciferase reporter were exposed to LPS (bacterial lipopolysaccharide), TNF-alpha (Tumor Necrosis Factor-alpha) or 4 kJ m(-2) UV-B radiation. NF-kappaB decoy oligonucleotides were also administered in some of the UV-B experiments. Following various exposure times, the mice were sacrificed and whole eyes or corneal tissues were obtained. Whole eyes were examined for scattering using a point-source optical imaging technique. Tissue homogenates were examined for luciferase activity using a luminometer. TNF-alpha and LPS-injected NF-kappaB-luciferase transgenic mice demonstrated 3-10-fold increases in cornea NF-kappaB with peak activities at 4 and 6 hr post-injection, respectively. Mice exposed to 4 kJ m(-2) UV-B exhibited a 3-fold increase in NF-kappaB activity 4 hr post-exposure. The administration of NF-kappaB-decoy oligonucleotides to mice had the effect of reducing UV-B-induced NF-kappaB activity in the cornea and significantly increasing the amount of light scattering in UV-B exposed corneas 7 days post-UV-B exposure when compared to sham injected mice. These results indicate that NF-kappaB is activated in cornea in pathologies that involves increased plasma levels of LPS and TNF-alpha, as well as direct UV-B exposure, and suggest that NF-kappaB activation play an essential part in the corneal healing process.

  11. Case report: a novel KERA mutation associated with cornea plana and its predicted effect on protein function

    DEFF Research Database (Denmark)

    Roos, Laura; Bertelsen, Birgitte; Harris, Pernille

    2015-01-01

    of the keratocan gene (KERA) on chromosome 12q22. To date, only nine different disease-associated KERA mutations, including four missense mutations, have been described. Case presentation: In this report, we present clinical data from a Turkish family with autosomal recessive cornea plana. In some of the affected...

  12. Thermal lens measurements in the cornea.

    Science.gov (United States)

    Venkatesh, S; Guthrie, S; Cruickshank, F R; Bailey, R T; Foulds, W S; Lee, W R

    1985-02-01

    Q-switched pulses from a neodymium/YAG (yttrium-aluminium-garnet) laser were passed through corneal discs taken from the enucleated eyes of three baboons and four rabbits. The time course of heat dissipation following absorption of laser energy by the tissue was studied with the use of a second continuous wave laser beam acting as a probe. It was found that the absorption of each neodymium/YAG pulse created a transient divergent lens within the cornea as theoretical considerations predicted. The relaxation time that characterised the decay of this thermal lens for a 1/e laser beam diameter of 2.0 mm was found to be 2.3 +/- 0.1 s (mean +/- standard error for 12 separate groups of measurements). Our results show that Q-switched laser pulses passing through apparently unaffected transparent tissues can induce thermal lens effects which persist for several seconds. The optical transfer of each pulse in a stream will be identical only if enough time is left between pulses for the tissues to return to their initial state. Therefore, when such laser pulses sharply focused to perform high precision intraocular surgery are used, thermal lensing in the transparent ocular media must limit the rate at which pulses can be usefully delivered.

  13. Clinical characteristics of keratoconus patients in Malaysia: a review from a cornea specialist centre

    OpenAIRE

    Mohd-Ali, Bariah; Abdu, Mustafa; Yaw, Choong Yean; Mohidin, Norhani

    2012-01-01

    Purpose: To evaluate the demographic profile, refraction, visual acuity (VA), corneal curvature (K) and severity of keratoconus (KC) patients from a cornea specialist centre in Malaysia. This may improve the management of KC patients in this country. Methods: Records of 13,000 patients were reviewed. The patients were categorized into 4 age groups: (Gp 1: 42 years). Refraction and VA were determined using subjective refraction and Snellen chart. Corneal curvature was measured using Orbscan...

  14. Magical Engineering Plastic

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gwang Ung

    1988-01-15

    This book introduces engineering plastic about advantage of engineering plastic, plastic material from processing method, plastic shock, plastic until now, background of making of engineering plastic, wonderful engineering plastic science such as a high molecule and molecule, classification of high molecule, difference between metal and high molecule, heat and high molecule materials, and property of surface, engineering plastic of dream like from linseed oil to aramid, small dictionary of engineering plastic.

  15. Magical Engineering Plastic

    International Nuclear Information System (INIS)

    Kim, Gwang Ung

    1988-01-01

    This book introduces engineering plastic about advantage of engineering plastic, plastic material from processing method, plastic shock, plastic until now, background of making of engineering plastic, wonderful engineering plastic science such as a high molecule and molecule, classification of high molecule, difference between metal and high molecule, heat and high molecule materials, and property of surface, engineering plastic of dream like from linseed oil to aramid, small dictionary of engineering plastic.

  16. International policies to reduce plastic marine pollution from single-use plastics (plastic bags and microbeads): A review.

    Science.gov (United States)

    Xanthos, Dirk; Walker, Tony R

    2017-05-15

    Marine plastic pollution has been a growing concern for decades. Single-use plastics (plastic bags and microbeads) are a significant source of this pollution. Although research outlining environmental, social, and economic impacts of marine plastic pollution is growing, few studies have examined policy and legislative tools to reduce plastic pollution, particularly single-use plastics (plastic bags and microbeads). This paper reviews current international market-based strategies and policies to reduce plastic bags and microbeads. While policies to reduce microbeads began in 2014, interventions for plastic bags began much earlier in 1991. However, few studies have documented or measured the effectiveness of these reduction strategies. Recommendations to further reduce single-use plastic marine pollution include: (i) research to evaluate effectiveness of bans and levies to ensure policies are having positive impacts on marine environments; and (ii) education and outreach to reduce consumption of plastic bags and microbeads at source. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Creating physically-based three-dimensional microstructures: Bridging phase-field and crystal plasticity models.

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Hojun [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Owen, Steven J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Abdeljawad, Fadi F. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hanks, Byron [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Battaile, Corbett Chandler [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    In order to better incorporate microstructures in continuum scale models, we use a novel finite element (FE) meshing technique to generate three-dimensional polycrystalline aggregates from a phase field grain growth model of grain microstructures. The proposed meshing technique creates hexahedral FE meshes that capture smooth interfaces between adjacent grains. Three dimensional realizations of grain microstructures from the phase field model are used in crystal plasticity-finite element (CP-FE) simulations of polycrystalline a -iron. We show that the interface conformal meshes significantly reduce artificial stress localizations in voxelated meshes that exhibit the so-called "wedding cake" interfaces. This framework provides a direct link between two mesoscale models - phase field and crystal plasticity - and for the first time allows mechanics simulations of polycrystalline materials using three-dimensional hexahedral finite element meshes with realistic topological features.

  18. In vivo laser confocal microscopy findings of a cornea with osteogenesis imperfecta

    Directory of Open Access Journals (Sweden)

    Kobayashi A

    2014-02-01

    Full Text Available Akira Kobayashi, Tomomi Higashide, Hideaki Yokogawa, Natsuko Yamazaki, Toshinori Masaki, Kazuhisa Sugiyama Department of Ophthalmology, Kanazawa University Graduate School of Medical Science, Kanazawa, Japan Objective: To report the in vivo laser confocal microscopy findings of a cornea with osteogenesis imperfecta (OI with special attention to the abnormality of Bowman's layer and sub-Bowman's fibrous structures (K-structures. Patients and methods: Two patients (67-year-old male and his 26-year-old son with OI type I were included in this study. Slit lamp biomicroscopic and in vivo laser confocal microscopic examinations were performed for both patients. Central corneal thickness and central endothelial cell density were also measured. Results: Although the corneas looked clear with normal endothelial density for both eyes in both patients, they were quite thin (386 µm oculus dexter (OD (the right eye and 384 µm oculus sinister (OS (the left eye in the father and 430 µm OD and 425 µm OS in the son. In both patients, slit lamp biomicroscopic and in vivo laser confocal microscopic examination showed similar results. Anterior corneal mosaics produced by rubbing the eyelid under fluorescein were completely absent in both eyes. In vivo laser confocal microscopy revealed an absent or atrophic Bowman's layer; a trace of a presumed Bowman's layer and/or basement membrane was barely visible with high intensity. Additionally, K-structures were completely absent in both eyes. Conclusion: The absence of K-structures and fluorescein anterior corneal mosaics strongly suggested an abnormality of Bowman's layer in these OI patients. Keywords: osteogenesis imperfecta, K-structure, confocal microscopy, Bowman's layer

  19. Improvement in properties of plastic teeth by electron beam irradiation

    International Nuclear Information System (INIS)

    Sano, Yuko; Ishikawa, Shun-ichi; Seguchi, Tadao

    2011-01-01

    Improvement of the comfort and esthetics of artificial plastic teeth is desirable for the recently increasing numbers of elderly in society. Plastic teeth made of polycarbonate (PC) were modified by electron beam (EB) irradiation under specific conditions, and the change in the chemical properties of the PC was investigated. The water absorption, glucose attachment, level of bis-phenol-A (BPA) extraction, maltose adhesion, and mucin adhesion on the PC teeth were measured before and after EB irradiation. EB irradiation to a dose of 3.5 kGy at 150 o C in a nitrogen gas atmosphere reduced the water absorption by 20%, glucose absorption by 40%, maltose adhesion by 20%, and the amount of various amino acids, formed as the hydrolysis products of mucin, adhering on the PC teeth were reduced by 60-99%. The BPA content was lower than the detection limit for analysis of both the original and the EB irradiated PC teeth. - Highlights: → Radiation improvement of polycarbonate for plastic teeth by EB irradiation 3.5 kGy at 150 o C in inert gas. → Water and glucose absorption and maltose adhesion on PC teeth were much reduced. → Bis-phenol-A content from PC teeth was lower than the detection limit after irradiation.

  20. Partial denervation of sub-basal axons persists following debridement wounds to the mouse cornea.

    Science.gov (United States)

    Pajoohesh-Ganji, Ahdeah; Pal-Ghosh, Sonali; Tadvalkar, Gauri; Kyne, Briana M; Saban, Daniel R; Stepp, Mary Ann

    2015-11-01

    Although sensory reinnervation occurs after injury in the peripheral nervous system, poor reinnervation in the elderly and those with diabetes often leads to pathology. Here we quantify sub-basal axon density in the central and peripheral mouse cornea over time after three different types of injury. The mouse cornea is highly innervated with a dense array of sub-basal nerves that form a spiral called the vortex at the corneal center or apex; these nerves are readily detected within flat mounted corneas. After anesthesia, corneal epithelial cells were removed using either a dulled blade or a rotating burr within an area demarcated centrally with a 1.5 mm trephine. A third wound type, superficial trephination, involved demarcating the area with the 1.5 mm trephine but not removing cells. By 7 days after superficial trephination, sub-basal axon density returns to control levels; by 28 days the vortex reforms. Although axon density is similar to control 14 days after dulled blade and rotating burr wounding, defects in axon morphology at the corneal apex remain. After 14 days, axons retract from the center leaving the sub-basal axon density reduced by 37.2 and 36.8% at 28 days after dulled blade and rotating burr wounding, respectively, compared with control. Assessment of inflammation using flow cytometry shows that persistent inflammation is not a factor in the incomplete reinnervation. Expression of mRNAs encoding 22 regeneration-associated genes involved in axon targeting assessed by QPCR reveals that netrin-1 and ephrin signaling are altered after wounding. Subpopulations of corneal epithelial basal cells at the corneal apex stop expressing ki67 as early as 7 days after injury and by 14 and 28 days after wounding, many of these basal cells undergo apoptosis and die. Although sub-basal axons are restored to their normal density and morphology after superficial trephination, sub-basal axon recovery is partial after debridement wounds. The increase in corneal

  1. Photorefractive Keratectomy (PRK) is Safe and Effective for Patients with Myopia and Thin Corneas.

    Science.gov (United States)

    Naderi, Mostafa; Ghadamgahi, Saeed; Jadidi, Khosrow

    2016-01-01

    The aim of this study was to evaluate the long-term safety and efficacy of photorefractive keratectomy (PRK) for patients with myopia and thin corneas. In this retrospective case series, we included 74 eyes of 38 patients with myopia and central corneal thickness (CCT) PRK and had a mean postoperative follow-up period of four years. The following factors were evaluated: CCT, refraction, uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), ablation depth, safety and efficacy indices (i.e., the ratio of the mean postoperative BCVA to the mean preoperative BCVA, and the ratio of the mean postoperative UCVA to mean preoperative the BCVA, respectively), and evidence of corneal ectasia (based on Orbscan topography images).The patients were aged 20 - 46 years (mean ±SD age, 28.18± 6.82 years). The mean ± SD pre- and postoperative CCTwas485.92 ± 9.27 µm and 434.84 ± 20.48 µm, respectively. The mean ± SD pre- and postoperative myopia was -2.77 D ± 1.51 and -0.24 ± 0.39 D, respectively, and the mean ± SD pre- and postoperative astigmatism was -0.82 D ± 0.99 and -0.37 ± 0.37 D, respectively. The mean pre- and postoperative BCVA and postoperative UCVA was 0.011 ± 0.03 Logarithm of the Minimum Angle of Resolution (log MAR), 0.003 ± 0.01 log MAR, and 0.054 ± 0.09 log MAR, respectively. The mean ± SD ablation depth, safety index and efficacy index was 54.34 ± 16.28 µm, 0.02 ± 0.12, and 0.11 ± 0.50, respectively. Regarding the postoperative corneal clarity, 72 eyes (97.3%) had a clear cornea (grade 0) and the remaining two eyes of one patient (2.70%) had a trace haze (grade 1). There was no evidence of corneal ectasia on any of the Orbscan topography images. Thus, among patients with myopia and thin corneas (PRK seems to be acceptable in terms of both safety and efficacy 4 years after surgery, based on the stability of postoperative refraction, visual acuity, and topographic outcomes, and outcomes based on the safety and efficacy indexes.

  2. Role of nanotechnology in development of artificial organs.

    Science.gov (United States)

    Teoh, G Z; Klanrit, P; Kasimatis, M; Seifalian, A M

    2015-02-01

    Improvements in our understanding of the interactions between implants and cells have directed attention towards nanoscale technologies. To date, nanotechnology has played a helping hand in the development of synthetic artificial organs and regenerative medicine. This includes the production of smart nanocomposite materials; fluorescent nanoparticles like Quantum Dots (QD) and magnetic nano particles (MNP) for stem cell tracking; and carbon nanotubes (CNT) and graphene for enhancement of material properties. The scope of this paper includes the role of nanoparticles in the development of nanomaterials; the chemical surface modifications possible to improve implant function and an overview of the performance of nano-engineered organs thus far. This includes implants developed for aesthetic purposes like nasal and auricular scaffolds, plastic and reconstructive surgical constructs (i.e. dermal grafts), hollow organs for cardiothoracic applications; and last but not least, orthopedic implants. The five-year outlook for nano-enhanced artificial organs is also discussed, highlighting the key research and development areas, available funds and the hurdles we face in accomplishing progression from prototypes on the laboratory bench to off-the-shelf products for the consumer market. Ultimately, this review aims to delineate the advantages of incorporating nanotechnology, as an individual entity or as a part of a construct for the development of tissue engineering scaffolds and/or artificial organs, and unravel the mechanisms of tissue cell-biomaterial interactions at the nanoscale, allowing for better progress in the development and optimization of unique nanoscale surface features for a wide range of applications.

  3. Artificial intelligence

    CERN Document Server

    Hunt, Earl B

    1975-01-01

    Artificial Intelligence provides information pertinent to the fundamental aspects of artificial intelligence. This book presents the basic mathematical and computational approaches to problems in the artificial intelligence field.Organized into four parts encompassing 16 chapters, this book begins with an overview of the various fields of artificial intelligence. This text then attempts to connect artificial intelligence problems to some of the notions of computability and abstract computing devices. Other chapters consider the general notion of computability, with focus on the interaction bet

  4. Transport modeling of sorbing tracers in artificial fractures

    International Nuclear Information System (INIS)

    Keum, Dong Kwon; Baik, Min Hoon; Park, Chung Kyun; Cho, Young Hwan; Hahn, Phil Soo.

    1998-02-01

    This study was performed as part of a fifty-man year attachment program between AECL (Atomic Energy Canada Limited) and KAERI. Three kinds of computer code, HDD, POMKAP and VAMKAP, were developed to predict transport of contaminants in fractured rock. MDDM was to calculate the mass transport of contaminants in a single fracture using a simple hydrodynamic dispersion diffusion model. POMKAP was to predict the mass transport of contaminants by a two-dimensional variable aperture model. In parallel with modeling, the validation of models was also performed through the analysis of the migration experimental data obtained in acrylic plastic and granite artificial fracture system at the Whiteshell laboratories, AECL, Canada. (author). 34 refs., 11 tabs., 76 figs

  5. Transport modeling of sorbing tracers in artificial fractures

    Energy Technology Data Exchange (ETDEWEB)

    Keum, Dong Kwon; Baik, Min Hoon; Park, Chung Kyun; Cho, Young Hwan; Hahn, Phil Soo

    1998-02-01

    This study was performed as part of a fifty-man year attachment program between AECL (Atomic Energy Canada Limited) and KAERI. Three kinds of computer code, HDD, POMKAP and VAMKAP, were developed to predict transport of contaminants in fractured rock. MDDM was to calculate the mass transport of contaminants in a single fracture using a simple hydrodynamic dispersion diffusion model. POMKAP was to predict the mass transport of contaminants by a two-dimensional variable aperture model. In parallel with modeling, the validation of models was also performed through the analysis of the migration experimental data obtained in acrylic plastic and granite artificial fracture system at the Whiteshell laboratories, AECL, Canada. (author). 34 refs., 11 tabs., 76 figs.

  6. Cellular basis of morphological variation and temperature-related plasticity in Drosophila melanogaster strains with divergent wing shapes.

    Science.gov (United States)

    Torquato, Libéria Souza; Mattos, Daniel; Matta, Bruna Palma; Bitner-Mathé, Blanche Christine

    2014-12-01

    Organ shape evolves through cross-generational changes in developmental patterns at cellular and/or tissue levels that ultimately alter tissue dimensions and final adult proportions. Here, we investigated the cellular basis of an artificially selected divergence in the outline shape of Drosophila melanogaster wings, by comparing flies with elongated or rounded wing shapes but with remarkably similar wing sizes. We also tested whether cellular plasticity in response to developmental temperature was altered by such selection. Results show that variation in cellular traits is associated with wing shape differences, and that cell number may play an important role in wing shape response to selection. Regarding the effects of developmental temperature, a size-related plastic response was observed, in that flies reared at 16 °C developed larger wings with larger and more numerous cells across all intervein regions relative to flies reared at 25 °C. Nevertheless, no conclusive indication of altered phenotypic plasticity was found between selection strains for any wing or cellular trait. We also described how cell area is distributed across different intervein regions. It follows that cell area tends to decrease along the anterior wing compartment and increase along the posterior one. Remarkably, such pattern was observed not only in the selected strains but also in the natural baseline population, suggesting that it might be canalized during development and was not altered by the intense program of artificial selection for divergent wing shapes.

  7. Behaviour of glutathione in the cornea epithelium of cattle and rabbits under the influence of infrared radiation

    International Nuclear Information System (INIS)

    Scharsich, G.

    1978-01-01

    After creating a keratitis photoelectrica by means of a mercury/quartz analysis lamp, the concentration of GSH (glutathion, reduced) and GSSG (glutathion, oxidised) in the cornea epithelium of cattle and of rabbits at different times after irradiation was determined. The question of whether ultraviolet radiation considerably influences the GSH/GSSG quotient before the keratitis photoelectrica is fully formed morphologically, could be answered as follows: There is no considerable change in the GSH/GSSG quotient during the first 7-10 hours after the irradiation. Then, when there is, also morphologically, a keratitis photoelectrica, the GSH/GSSG quotient is doubled. The linkage of the GSH/GSSG system and hexosephosphatshunt via the NADP/NADPH system leads us to the conclusion that irradiation does not cause any direct changes in the GSH/GSSG system. Only when the cornea epithelium visably disintegrates an increased reduction of the glutathion occurs, like in several other damaging influences. Thus the found increase of the GSH/GSSG quotient 7-10 hours after ultraviolet irradiation might be unspecific. (orig./AJ) [de

  8. The effects of oral and topical corticosteroid in rabbit corneas.

    Science.gov (United States)

    Araki-Sasaki, Kaoru; Katsuta, Osamu; Mano, Hidetoshi; Nagano, Takashi; Nakamura, Masatsugu

    2016-09-05

    To determine the most effective route of administration of corticosteroids in the treatment of ocular surface disease, by characterizing the difference between oral prednisolone and topical dexamethasone administration using an animal model. Pharmacokinetic analyses determined the corticosteroid concentrations in the normal ocular tissues of rabbits after oral or topical administration of corticosteroids using LC-MS/MS. In wound healing analyses, the area of the epithelial defect created by keratectomy using a 6-mm trephine was calculated with an image analyzer using an orally or topically steroid-administrated animal model. The average size of basal epithelial cells, the frequency of mitotic basal epithelial cells, the number of squamous cells, and the number of hypertrophic stromal fibroblasts were determined in the enucleated corneal tissues after wound closure. By slit lamp examination, no remarkable differences were observed between orally and topically administered groups. Pharmacokinetic analyses showed that the distribution of dexamethasone after topical administration was superior to that after oral administration in the cornea. In contrast, both concentrations of corticosteroid applied topically and orally were similar with regards to AUCs (area under the concentration-time curve) in the conjunctiva. Although the healing rate was slower in the topical group, all corneas were almost healed within 96 h in the wound healing analysis. According to the histological analyses of epithelial cells, the average basal cell size was larger, the frequency of mitotic basal cells was greater, and the number of squamous epithelial cell layers was lower in the topically administered group although all of these differences were with no statistical significance. However, the number of hypertrophic stromal fibroblasts in the topically administered group was significantly lower than that in the orally administered group. There are different distributions and effects between

  9. Artificial Consciousness or Artificial Intelligence

    Directory of Open Access Journals (Sweden)

    Spanache Florin

    2017-05-01

    Full Text Available Artificial intelligence is a tool designed by people for the gratification of their own creative ego, so we can not confuse conscience with intelligence and not even intelligence in its human representation with conscience. They are all different concepts and they have different uses. Philosophically, there are differences between autonomous people and automatic artificial intelligence. This is the difference between intelligence and artificial intelligence, autonomous versus automatic. But conscience is above these differences because it is neither conditioned by the self-preservation of autonomy, because a conscience is something that you use to help your neighbor, nor automatic, because one’s conscience is tested by situations which are not similar or subject to routine. So, artificial intelligence is only in science-fiction literature similar to an autonomous conscience-endowed being. In real life, religion with its notions of redemption, sin, expiation, confession and communion will not have any meaning for a machine which cannot make a mistake on its own.

  10. Social influence of a religious hero: the late Cardinal Stephen Kim Sou-hwan's effect on cornea donation and volunteerism.

    Science.gov (United States)

    Bae, Hyuhn-Suhck; Brown, William J; Kang, Seok

    2011-01-01

    This study examined the mediated influence of a celebrated religious hero in South Korea, Cardinal Stephen Kim, through two forms of involvement--parasocial interaction and identification--on intention toward cornea donation and volunteerism, and it investigated how the news media diffused of his death. A structural equation modeling analysis with a Web-based voluntary survey of more than 1,200 people in South Korea revealed a multistep social influence process, beginning with parasocial interaction with Cardinal Kim, leading to identification with him, which predicted intention toward cornea donation and volunteerism. Additional investigations found that news of Cardinal Kim's death diffused rapidly through media and interpersonal communication. Results of this study demonstrate that religious leaders who achieve a celebrity hero status can prompt public discussion of important issues rather quickly through extensive media coverage, enabling them to promote prosocial behavior and positively affect public health.

  11. Microscopia confocal de la córnea en facoemulsificación Confocal microscopy of the cornea on phacoemulsification

    Directory of Open Access Journals (Sweden)

    Juan Raúl Hernández Silva

    2011-12-01

    Full Text Available Objetivo: Determinar los cambios estructurales de la córnea en la cirugía de catarata por facoemulsificación sin complicaciones. Métodos: Se realizó un estudio prospectivo de pacientes operados de catarata por facoemulsificación coaxial por la técnica de pre chop sin complicaciones. A estos se les realizó microscopia confocal de la córnea con el CONFOSCAN 4 (Nidek Technologies con el objetivo de 40x y adaptador Z-Ring. Se realizó el estudio en el preoperatorio y en el posoperatorio (a las 24 horas, después de una semana, de un mes y a los tres meses. Resultados: Se demostraron cambios estructurales en la córnea como células epiteliales con núcleos hiperreflectivos alargadas en ocasiones y áreas de hiperreflectividad anómala a las 24 horas del posoperatorio. Persistieron queratocitos activados y la disminución de la hiperreflectividad de la matriz extracelular que desapareció al mes. Conclusiones: Aunque por biomicroscopia no se observen alteraciones corneales en el posoperatorio de la cirugía de catarata por facoemulsificación, sí se pueden demostrar por microscopia confocal de la córnea. Estas variaciones no influyen en la recuperación visual óptima de los pacientes.Objective: To determine the structural changes in the cornea in the cataract surgery using phacoemulsification without complications. Methods: A prospective study of patients operated on from cataract using the coaxial phacoemulsification (Pre Chop technique without complications was carried out. These patients also underwent confocal microscopy of the cornea with Confoscan4 (Nidek Technologies with 40x target and Z - Ring adapter. The study was performed in the preoperative period and postoperative period for 24 hours, one week, one month and three months after surgery. Results: Structural changes were observed in the cornea such as epithelial cells with hypereflectivity nucleus, occasionally elongated, , areas of anomalous hypereflectivity 24 hours after

  12. Técnica de separação da membrana de Descemet para transplante de células endoteliais da córnea: estudo experimental em coelhos Technique for separating Descemet membrane for corneal endothelial cells transplantation: experimental study in rabbits

    Directory of Open Access Journals (Sweden)

    Daniel Wasilewski

    2010-02-01

    Full Text Available OBJETIVO: Avaliar a porcentagem de dano endotelial induzido por uma técnica cirúrgica para a separação da membrana de Descemet contendo endotélio sadio, analisar a viabilidade e eficácia desta técnica, e avaliar a porcentagem de dano endotelial causado pela inversão da córnea em câmara anterior artificial. MÉTODOS: As córneas de três grupos de 12 coelhos da linhagem Nova Zelândia foram avaliadas. O grupo 1 foi usado como controle; portanto, as córneas foram analisadas após coletadas e trepanadas. O grupo 2 foi analisado após a inversão da córnea (endotélio para cima na posição convexa, montada em câmara anterior artificial, para o cálculo da porcentagem do dano endotelial induzido por esta inversão. O grupo 3 foi avaliado após a separação entre a membrana de Descemet e o estroma com o uso de substância viscoelástica em córneas invertidas e montadas em câmara anterior artificial. O dano endotelial foi avaliado por meio de fotografias digitais tiradas no microscópio após impregnar o endotélio com vermelho de alizarina. Amostras do grupo 3 foram processadas para avaliação histopatológica. RESULTADOS: O grupo 3 (separação viscoelástica apresentou um índice de lesão celular endotelial de 10,06%, o grupo 2 apresentou um índice de 3,58% e o grupo controle um índice de 0,18% de lesão celular endotelial (pPURPOSE: To evaluate the percentage of endothelial cell damage induced during a surgical technique of Descemet's membrane separation containing healthy endothelium, analyze the viability and efficacy of this technique, and evaluate the percentage of endothelial cell damage caused by inversion of the cornea on an artificial anterior chamber. METHODS: The corneas from three groups of 12 New Zealand rabbits were evaluated. The Group one was used as the control, so the corneas were analyzed after collected and trephinated. The Group two was analyzed after inversion of the cornea (endothelial side up at a convex

  13. Age-related changes in superoxide dismutase, glutathione peroxidase, catalase and xanthine oxidoreductase/xanthine oxidase activities in the rabbit cornea

    Czech Academy of Sciences Publication Activity Database

    Čejková, Jitka; Vejražka, M.; Pláteník, J.; Štípek, S.

    2004-01-01

    Roč. 39, - (2004), s. 1537-1543 ISSN 0531-5565 R&D Projects: GA ČR GA304/03/0419 Institutional research plan: CEZ:AV0Z5039906; CEZ:AV0Z5008914 Keywords : aging * cornea Subject RIV: FF - HEENT, Dentistry Impact factor: 2.880, year: 2004

  14. Sphere-forming cells from peripheral cornea demonstrate a wound-healing response to injury.

    Science.gov (United States)

    Huang, Stephanie U; Yoon, Jinny J; Ismail, Salim; McGhee, Jennifer J; Sherwin, Trevor

    2015-11-01

    The cornea is the initial refractive interface of the eye. Its transparency is critical for clear vision and is maintained by stem cells which also act to repair injury inflicted by external insults, such as chemical and thermal burns. Damage to the epithelium compromises its clarity and can reduce or eliminate the stem cell population, diminishing the ability for self-repair. This condition has been termed "limbal stem cell deficiency"; severe cases can lead to corneal blindness. Sphere-forming cells isolated from peripheral cornea are a potential source of stem and progenitor cells for corneal repair. When provided with appropriate substrate, these spheres have the ability to adhere and for cells to migrate outwards akin to that of their natural environment. Direct compression injury and remote scratch injury experiments were conducted on the sphere cells to gauge their wound healing capacity. Measures of proliferation, differentiation, and migration were assessed by immunohistochemical detection of EdU incorporation, α-smooth muscle actin expression and confocal image analysis, respectively. Both modes of injury were observed to draw responses from the spheres indicating wound healing processes. Direct wounding induced a rapid, but transient increase in expression of α-SMA, a marker of corneal myofibroblasts, followed by a proliferative and increasing migratory response. The spheres were observed to respond to remote injury as entire units, with no directional response seen for targeted repair over the scratch injury area. These results give strength to the future use of these peripheral corneal spheres as transplantable units for the regeneration of corneal tissue. © 2015 International Federation for Cell Biology.

  15. Plastic Surgery

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Plastic Surgery KidsHealth / For Teens / Plastic Surgery What's in ... her forehead lightened with a laser? What Is Plastic Surgery? Just because the name includes the word " ...

  16. Synaptic plasticity and memory functions achieved in a WO3−x-based nanoionics device by using the principle of atomic switch operation

    International Nuclear Information System (INIS)

    Yang, Rui; Terabe, Kazuya; Yao, Yiping; Tsuruoka, Tohru; Hasegawa, Tsuyoshi; Gimzewski, James K; Aono, Masakazu

    2013-01-01

    A compact neuromorphic nanodevice with inherent learning and memory properties emulating those of biological synapses is the key to developing artificial neural networks rivaling their biological counterparts. Experimental results showed that memorization with a wide time scale from volatile to permanent can be achieved in a WO 3−x -based nanoionics device and can be precisely and cumulatively controlled by adjusting the device’s resistance state and input pulse parameters such as the amplitude, interval, and number. This control is analogous to biological synaptic plasticity including short-term plasticity, long-term potentiation, transition from short-term memory to long-term memory, forgetting processes for short- and long-term memory, learning speed, and learning history. A compact WO 3−x -based nanoionics device with a simple stacked layer structure should thus be a promising candidate for use as an inorganic synapse in artificial neural networks due to its striking resemblance to the biological synapse. (paper)

  17. Detection of drugs and explosives using neutron computerized tomography and artificial intelligence techniques

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, F.J.O. [Instituto de Engenharia Nuclear, Cidade Universitaria, Rio de Janeiro, CEP 21945-970, Caixa Postal 68550 (Brazil)], E-mail: fferreira@ien.gov.br; Crispim, V.R.; Silva, A.X. [DNC/Poli, PEN COPPE CT, UFRJ Universidade Federal do Rio de Janeiro, CEP 21941-972, Caixa Postal 68509, Rio de Janeiro (Brazil)

    2010-06-15

    In this study the development of a methodology to detect illicit drugs and plastic explosives is described with the objective of being applied in the realm of public security. For this end, non-destructive assay with neutrons was used and the technique applied was the real time neutron radiography together with computerized tomography. The system is endowed with automatic responses based upon the application of an artificial intelligence technique. In previous tests using real samples, the system proved capable of identifying 97% of the inspected materials.

  18. Detection of drugs and explosives using neutron computerized tomography and artificial intelligence techniques

    International Nuclear Information System (INIS)

    Ferreira, F.J.O.; Crispim, V.R.; Silva, A.X.

    2010-01-01

    In this study the development of a methodology to detect illicit drugs and plastic explosives is described with the objective of being applied in the realm of public security. For this end, non-destructive assay with neutrons was used and the technique applied was the real time neutron radiography together with computerized tomography. The system is endowed with automatic responses based upon the application of an artificial intelligence technique. In previous tests using real samples, the system proved capable of identifying 97% of the inspected materials.

  19. Plastic dosimeter

    International Nuclear Information System (INIS)

    Nagai, Shiro; Matsuda, Kohji.

    1988-01-01

    The report outlines major features and applications of plastic dosimeters. Some plastic dosimeters, including the CTA and PVC types, detect the response of the plastic material itself to radiations while others, such as pigment-added plastic dosimeters, contain additives as radiation detecting material. Most of these dosimeters make use of color centers produced in the dosimeter by radiations. The PMMA dosimeter is widely used in the field of radiation sterilization of food, feed and medical apparatus. The blue cellophane dosimeter is easy to handle if calibrated appropriately. The rad-color dosimeter serves to determine whether products have been irradiated appropriately. The CTA dosimeter has better damp proofing properties than the blue cellophane type. The pigment-added plastic dosimeter consists of a resin such as nylon, CTA or PVC that contains a dye. Some other plastic dosimeters are also described briefly. Though having many advantages, these plastic dosimeter have disadvantages as well. Some of their major disadvantages, including fading as well as large dependence on dose, temperature, humidity and anviroment, are discussed. (Nogami, K.)

  20. Behavioral plasticity through the modulation of switch neurons.

    Science.gov (United States)

    Vassiliades, Vassilis; Christodoulou, Chris

    2016-02-01

    A central question in artificial intelligence is how to design agents capable of switching between different behaviors in response to environmental changes. Taking inspiration from neuroscience, we address this problem by utilizing artificial neural networks (NNs) as agent controllers, and mechanisms such as neuromodulation and synaptic gating. The novel aspect of this work is the introduction of a type of artificial neuron we call "switch neuron". A switch neuron regulates the flow of information in NNs by selectively gating all but one of its incoming synaptic connections, effectively allowing only one signal to propagate forward. The allowed connection is determined by the switch neuron's level of modulatory activation which is affected by modulatory signals, such as signals that encode some information about the reward received by the agent. An important aspect of the switch neuron is that it can be used in appropriate "switch modules" in order to modulate other switch neurons. As we show, the introduction of the switch modules enables the creation of sequences of gating events. This is achieved through the design of a modulatory pathway capable of exploring in a principled manner all permutations of the connections arriving on the switch neurons. We test the model by presenting appropriate architectures in nonstationary binary association problems and T-maze tasks. The results show that for all tasks, the switch neuron architectures generate optimal adaptive behaviors, providing evidence that the switch neuron model could be a valuable tool in simulations where behavioral plasticity is required. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Prevalence of spheroidal degeneration of cornea and its association with other eye diseases in tribes of Western Rajasthan

    Directory of Open Access Journals (Sweden)

    Amit Mohan

    2017-01-01

    Full Text Available Purpose: To determine the prevalence of spheroidal degeneration of cornea (SDC and its association with other eye diseases in the tribes of South-West Rajasthan. Methods: A total of 5012 patients were examined on slit lamp for the diagnosis of SDC. Diagnosis of SDC was made based on presence of amber granules in the superficial stroma of peripheral interpalpebral cornea with increasing opacification, coalescence and central spread or nodular and hazy surrounding stroma and divided in three stages. Results: The prevalence of SDC was 10.7%. Around 55% of the total of 535 cases examined were found to have Stage I followed by Stage II (32% and Stage III (13%. The prevalence is greatest in both men and women over 70 years of age. The severity of SDC is greater in men. SDC was significantly associated with pterygium and pseudocapsular exfoliation. Conclusion: Extreme temperature, low humidity, dust, high wind, and microtrauma caused by sand particles are the probable etiologies for higher prevalence of this kind of degeneration in this region.

  2. Control of Scar Tissue Formation in the Cornea: Strategies in Clinical and Corneal Tissue Engineering

    Directory of Open Access Journals (Sweden)

    Samantha L. Wilson

    2012-09-01

    Full Text Available Corneal structure is highly organized and unified in architecture with structural and functional integration which mediates transparency and vision. Disease and injury are the second most common cause of blindness affecting over 10 million people worldwide. Ninety percent of blindness is permanent due to scarring and vascularization. Scarring caused via fibrotic cellular responses, heals the tissue, but fails to restore transparency. Controlling keratocyte activation and differentiation are key for the inhibition and prevention of fibrosis. Ophthalmic surgery techniques are continually developing to preserve and restore vision but corneal regression and scarring are often detrimental side effects and long term continuous follow up studies are lacking or discouraging. Appropriate corneal models may lead to a reduced need for corneal transplantation as presently there are insufficient numbers or suitable tissue to meet demand. Synthetic optical materials are under development for keratoprothesis although clinical use is limited due to implantation complications and high rejection rates. Tissue engineered corneas offer an alternative which more closely mimic the morphological, physiological and biomechanical properties of native corneas. However, replication of the native collagen fiber organization and retaining the phenotype of stromal cells which prevent scar-like tissue formation remains a challenge. Careful manipulation of culture environments are under investigation to determine a suitable environment that simulates native ECM organization and stimulates keratocyte migration and generation.

  3. plastic waste recycling

    African Journals Online (AJOL)

    Dr Ahmed

    incinerators is increasing around the world. Discarded plastic products ... Agency (EPA) estimated that the amount of plastics throw away is. 50 % greater in the ... The waste plastics were identified using the Society of the Plastic. Industry (SPI) ...

  4. Oxidative Stress to the Cornea, Changes in Corneal Optical Properties, and Advances in Treatment of Corneal Oxidative Injuries

    Czech Academy of Sciences Publication Activity Database

    Čejka, Čestmír; Čejková, Jitka

    2015-01-01

    Roč. 2015, Mar 11 (2015), s. 591530 ISSN 1942-0900 R&D Projects: GA ČR(CZ) GA14-12580S Keywords : experimental autoimmune uveitis * eye sjogrens-syndrome * rabbit cornea * aldehyde dehydrogenase * uvb rays * glutathione-peroxidase * superoxide-dismutase * refractive-index * reactive oxygen * alkali-burn Subject RIV: FF - HEENT, Dentistry Impact factor: 4.492, year: 2015

  5. Lens regeneration in axolotl: new evidence of developmental plasticity

    Directory of Open Access Journals (Sweden)

    Suetsugu-Maki Rinako

    2012-12-01

    Full Text Available Abstract Background Among vertebrates lens regeneration is most pronounced in newts, which have the ability to regenerate the entire lens throughout their lives. Regeneration occurs from the dorsal iris by transdifferentiation of the pigment epithelial cells. Interestingly, the ventral iris never contributes to regeneration. Frogs have limited lens regeneration capacity elicited from the cornea during pre-metamorphic stages. The axolotl is another salamander which, like the newt, regenerates its limbs or its tail with the spinal cord, but up until now all reports have shown that it does not regenerate the lens. Results Here we present a detailed analysis during different stages of axolotl development, and we show that despite previous beliefs the axolotl does regenerate the lens, however, only during a limited time after hatching. We have found that starting at stage 44 (forelimb bud stage lens regeneration is possible for nearly two weeks. Regeneration occurs from the iris but, in contrast to the newt, regeneration can be elicited from either the dorsal or the ventral iris and, occasionally, even from both in the same eye. Similar studies in the zebra fish concluded that lens regeneration is not possible. Conclusions Regeneration of the lens is possible in the axolotl, but differs from both frogs and newts. Thus the axolotl iris provides a novel and more plastic strategy for lens regeneration.

  6. Artificial skin and patient simulator comprising the artificial skin

    NARCIS (Netherlands)

    2011-01-01

    The invention relates to an artificial skin (10, 12, 14), and relates to a patient simulator (100) comprising the artificial skin. The artificial skin is a layered structure comprising a translucent cover layer (20) configured for imitating human or animal skin, and comprising a light emitting layer

  7. Oral epithelial cell reaction after exposure to Invisalign plastic material.

    Science.gov (United States)

    Premaraj, Thyagaseely; Simet, Samantha; Beatty, Mark; Premaraj, Sundaralingam

    2014-01-01

    Invisalign plastic aligners (Align Technology, Santa Clara, Calif) are used to correct malocclusions. The aligners wrap around the teeth and are in contact with gingival epithelium during treatment. The purpose of this study was to evaluate the cellular responses of oral epithelium exposed to Invisalign plastic in vitro. Oral epithelial cells were exposed to eluate obtained by soaking Invisalign plastic in either saline solution or artificial saliva for 2, 4, and 8 weeks. Cells grown in media containing saline solution or saliva served as controls. Morphologic changes were assessed by light microscopy. The 3-[4, 5-dimethythiazol- 2-yl]-2, 5-diphenyl tetrazolium bromide assay and flow cytometry were used to determine cell viability and membrane integrity, respectively. Cellular adhesion and micromotion of epithelial cells were measured in real time by electrical cell-substrate impedance sensing. Cells exposed to saline-solution eluate appeared rounded, were lifted from the culture plates, and demonstrated significantly increased metabolic inactivity or cell death (P <0.05). Saliva eluates did not induce significant changes in cell viability compared with untreated cells. Flow cytometry and electric cell-substrate impedance sensing showed that cells treated with saline-solution eluate exhibited compromised membrane integrity, and reduced cell-to-cell contact and mobility when compared with saliva-eluate treatment. Exposure to Invisalign plastic caused changes in viability, membrane permeability, and adhesion of epithelial cells in a saline-solution environment. Microleakage and hapten formation secondary to compromised epithelial integrity might lead to isocyanate allergy, which could be systemic or localized to gingiva. However, these results suggest that saliva might offer protection. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  8. Direct liquefaction of plastics and coprocessing of coal with plastics

    Energy Technology Data Exchange (ETDEWEB)

    Huffman, G.P.; Feng, Z.; Mahajan, V. [Univ. of Kentucky, Lexington, KY (United States)

    1995-12-31

    The objectives of this work were to optimize reaction conditions for the direct liquefaction of waste plastics and the coprocessing of coal with waste plastics. In previous work, the direct liquefaction of medium and high density polyethylene (PE), polypropylene (PPE), poly(ethylene terephthalate) (PET), and a mixed plastic waste, and the coliquefaction of these plastics with coals of three different ranks was studied. The results established that a solid acid catalyst (HZSM-5 zeolite) was highly active for the liquefaction of the plastics alone, typically giving oil yields of 80-95% and total conversions of 90-100% at temperatures of 430-450 {degrees}C. In the coliquefaction experiments, 50:50 mixtures of plastic and coal were used with a tetralin solvent (tetralin:solid = 3:2). Using approximately 1% of the HZSM-5 catalyst and a nanoscale iron catalyst, oil yields of 50-70% and total conversion of 80-90% were typical. In the current year, further investigations were conducted of the liquefaction of PE, PPE, and a commingled waste plastic obtained from the American Plastics Council (APC), and the coprocessing of PE, PPE and the APC plastic with Black Thunder subbituminous coal. Several different catalysts were used in these studies.

  9. Artificial Intelligence.

    Science.gov (United States)

    Information Technology Quarterly, 1985

    1985-01-01

    This issue of "Information Technology Quarterly" is devoted to the theme of "Artificial Intelligence." It contains two major articles: (1) Artificial Intelligence and Law" (D. Peter O'Neill and George D. Wood); (2) "Artificial Intelligence: A Long and Winding Road" (John J. Simon, Jr.). In addition, it contains two sidebars: (1) "Calculating and…

  10. A role for smoothened during murine lens and cornea development.

    Directory of Open Access Journals (Sweden)

    Janet J Y Choi

    Full Text Available Various studies suggest that Hedgehog (Hh signalling plays roles in human and zebrafish ocular development. Recent studies (Kerr et al., Invest Ophthalmol Vis Sci. 2012; 53, 3316-30 showed that conditionally activating Hh signals promotes murine lens epithelial cell proliferation and disrupts fibre differentiation. In this study we examined the expression of the Hh pathway and the requirement for the Smoothened gene in murine lens development. Expression of Hh pathway components in developing lens was examined by RT-PCR, immunofluorescence and in situ hybridisation. The requirement of Smo in lens development was determined by conditional loss-of-function mutations, using LeCre and MLR10 Cre transgenic mice. The phenotype of mutant mice was examined by immunofluorescence for various markers of cell cycle, lens and cornea differentiation. Hh pathway components (Ptch1, Smo, Gli2, Gli3 were detected in lens epithelium from E12.5. Gli2 was particularly localised to mitotic nuclei and, at E13.5, Gli3 exhibited a shift from cytosol to nucleus, suggesting distinct roles for these transcription factors. Conditional deletion of Smo, from ∼E12.5 (MLR10 Cre did not affect ocular development, whereas deletion from ∼E9.5 (LeCre resulted in lens and corneal defects from E14.5. Mutant lenses were smaller and showed normal expression of p57Kip2, c-Maf, E-cadherin and Pax6, reduced expression of FoxE3 and Ptch1 and decreased nuclear Hes1. There was normal G1-S phase but decreased G2-M phase transition at E16.5 and epithelial cell death from E14.5-E16.5. Mutant corneas were thicker due to aberrant migration of Nrp2+ cells from the extraocular mesenchyme, resulting in delayed corneal endothelial but normal epithelial differentiation. These results indicate the Hh pathway is required during a discrete period (E9.5-E12.5 in lens development to regulate lens epithelial cell proliferation, survival and FoxE3 expression. Defective corneal development occurs

  11. Recycling of Plastic

    DEFF Research Database (Denmark)

    Christensen, Thomas Højlund; Fruergaard, Thilde

    2011-01-01

    Plastic is produced from fossil oil. Plastic is used for many different products. Some plastic products like, for example, wrapping foil, bags and disposable containers for food and beverage have very short lifetimes and thus constitute a major fraction of most waste. Other plastic products like...

  12. Cross-linking da cornea: protocolo padrão

    Directory of Open Access Journals (Sweden)

    Marcony R. Santhiago

    Full Text Available RESUMO O objetivo desta revisão é de determinar as indicações e eficácia da cirurgia que promove novas ligações covalentes entre as fibras de colágeno da córnea, conhecida como Cross-Linking (CXL, assim como esclarecer seus objetivos. O ceratocone é uma doença ectasica da córnea, bilateral, assimétrica, que, principalmente, cursa com encurvamento e afinamentos progressivo, e se inicia em geral na segunda década de vida. O uso primário do CXL tem sido na interrupção da progressão do Ceratocone. Apesar do conhecido encurvamento no estroma da córnea ocorrer nesses pacientes, a fisiopatologia por trás do ceratocone ainda é desconhecida e parece ser multifatorial. Pela evidencia literária disponível até o momento, o CXL da córnea esta, portanto indicado nos pacientes com doença em progressão. Concluímos que existe evidencia suficiente para afirmar que o CXL da córnea é eficaz na estabilização da doença ectásica da cornea.

  13. Effect of biometric characteristics on biomechanical properties of the cornea in cataract patient

    Directory of Open Access Journals (Sweden)

    Xue-Fei Song

    2016-06-01

    Full Text Available AIM: To determine the impact of biometric characteristics on the biomechanical properties of the human cornea using the ocular response analyzer (ORA and standard comprehensive ophthalmic examinations before and after standard phacoemulsification. METHODS: This study comprised 54 eyes with cataract with significant lens opacification in stages I or II that underwent phacoemulsification (2.8 mm incision. Corneal hysteresis (CH, corneal resistance factor (CRF, Goldmann-correlated intraocular pressure (IOPg, and corneal-compensated intraocular pressure (IOPcc were measured by ORA preoperatively and at 1mo postoperatively. Biometric characteristics were derived from corneal topography [TMS-5, anterior equivalent (EQTMS and cylindric (CYLTMS power], corneal tomography [Casia, anterior and posterior equivalent (EQaCASIC, EQpCASIA and cylindric (CYLaCASIA, CYLpCASIA power], keratometry [IOLMaster, anterior equivalent (EQIOL and cylindric (CYLIOL power] and autorefractor [anterior equivalent (EQAR]. Results from ORA were analyzed and correlated with those from all other examinations taken at the same time point. RESULTS: Preoperatively, CH correlated with EQpCASIA and CYLpCASIA only (P=0.001, P=0.002. Postoperatively, IOPg and IOPcc correlated with all equivalent powers (EQTMS, EQIOL, EQAR, EQaCASIA and EQpCASIA (P=0.001, P=0.007, P=0.001, P=0.015, P=0.03 for IOPg and P<0.001, P=0.003, P<0.001, P=0.009, P=0.014 for IOPcc. CH correlated postoperatively with EQaCASIA and EQpCASIC only (P=0.021, P=0.022. CONCLUSION: Biometric characteristics may significantly affect biomechanical properties of the cornea in terms of CH, IOPcc and IOPg before, but even more after cataract surgery.

  14. Big Data and Machine Learning in Plastic Surgery: A New Frontier in Surgical Innovation.

    Science.gov (United States)

    Kanevsky, Jonathan; Corban, Jason; Gaster, Richard; Kanevsky, Ari; Lin, Samuel; Gilardino, Mirko

    2016-05-01

    Medical decision-making is increasingly based on quantifiable data. From the moment patients come into contact with the health care system, their entire medical history is recorded electronically. Whether a patient is in the operating room or on the hospital ward, technological advancement has facilitated the expedient and reliable measurement of clinically relevant health metrics, all in an effort to guide care and ensure the best possible clinical outcomes. However, as the volume and complexity of biomedical data grow, it becomes challenging to effectively process "big data" using conventional techniques. Physicians and scientists must be prepared to look beyond classic methods of data processing to extract clinically relevant information. The purpose of this article is to introduce the modern plastic surgeon to machine learning and computational interpretation of large data sets. What is machine learning? Machine learning, a subfield of artificial intelligence, can address clinically relevant problems in several domains of plastic surgery, including burn surgery; microsurgery; and craniofacial, peripheral nerve, and aesthetic surgery. This article provides a brief introduction to current research and suggests future projects that will allow plastic surgeons to explore this new frontier of surgical science.

  15. Embryonic chicken cornea and cartilage synthesize type IX collagen molecules with different amino-terminal domains.

    OpenAIRE

    Svoboda, K K; Nishimura, I; Sugrue, S P; Ninomiya, Y; Olsen, B R

    1988-01-01

    We have analyzed embryonic chicken cornea for the presence of type IX collagen mRNA and protein. Using RNA transfer blot analysis, we demonstrate that alpha 1(IX) and alpha 2(IX) mRNAs are expressed by corneal epithelial cells at the time that the primary stromal components are synthesized. The levels of the mRNAs decrease with increasing developmental age and are barely detectable at day 11 of development. In contrast, type IX collagen protein is detectable by immunofluorescence at days 5 an...

  16. Repeatability of pachymetric mapping using fourier domain optical coherence tomography in corneas with opacities.

    Science.gov (United States)

    Samy El Gendy, Nehal M; Li, Yan; Zhang, Xinbo; Huang, David

    2012-04-01

    To evaluate the repeatability of Fourier domain optical coherence tomography (OCT) pachymetric mapping in patients with corneal opacities and to assess the reliability of Fourier domain OCT with 830 nm wavelength as a pachymetric measurement tool in opaque corneas. A Fourier domain OCT system was used to map the corneal thickness of patients with corneal scars or dystrophy. A retrospective study of a consecutive series was conducted. The repeatability was measured using pooled standard deviation of repeated measurements. A slit-scanning tomography device provided pachymetric mapping for comparison. Seventeen eyes of 12 patients with corneal scars (7 trauma and 3 post infection) or dystrophy (2 Reis-Bucklers and 5 granular dystrophy) were included. The posterior corneal boundary was detectable in all cases. The average corneal thickness measured by OCT was 536 ± 89 μm in central 2 mm area, 553 ± 76 μm in pericentral 2- to 5-mm area, and 508 ± 93 μm for the minimum corneal thickness. The slit-scanning tomography central corneal thickness, 433 ± 111 μm, was significantly lower than OCT readings (mean difference -91.1 ± 33.3 μm, P = 0.002). Repeatability of the OCT measurements was 2.1 μm centrally and 1.2 μm pericentrally. Pachymetric mapping with Fourier domain OCT was highly repeatable. Fourier domain OCT is a reliable pachymetric tool in opaque corneas. In comparison, corneal thickness measured by the slit-scanning tomography is significantly thinner than those measured by the Fourier domain OCT in the presence of corneal opacities.

  17. Proteomic Analyses of the Acute Tissue Response for Explant Rabbit Corneas and Engineered Corneal Tissue Models Following In Vitro Exposure to 1540 nm Laser Light

    National Research Council Canada - National Science Library

    Eurell, T. E; Johnson, T. E; Roach, W. P

    2005-01-01

    Two-dimensional electrophoresis and histomorphometry were used to determine if equivalent protein changes occurred within native rabbit corneas and engineered corneal tissue models following in vitro...

  18. Evaluation of possibilities of the plastic stone masonry of carbonate rocks in Slovakia

    Directory of Open Access Journals (Sweden)

    Peter Ružička

    2006-09-01

    Full Text Available At plastic processing of rocks, the size of mine blocks,is not decisive but aesthetically interesting textural and coloured parts of raw materials. Technologically are compact positions of travertine with a stripe texture, originating from the Hradišťa pod Vrátnom. An attractive raw material for the production of artificial jewelleries are onyx marbles from the Levice surrouting. In Spišské Podhradie honey-yellow stripy aragonite fills travertine rifts, suitable for the production of jewelleries. A small ornamental ware can also be produced from the compact travertine in Vyšné Ružbachy. A contrast textural arain of crinoid limestones from Krivoklát represents a quality raw material for the production of decorative plastics and jewelleries. The locality Prihradzany-Skalka provides guttenstein limestones, appropriate for the production of bigger plastics and utility articles. Aesthetically stand out articles from hallstatt limestones from Silická Brezová. For the figural treatment and the production of utility articles are suitable čorštynske limestones from the depositg Marmont - Stará Ľubovňa. The most widely used decorative stones are marbles from Tuhár. The interesting are pseudobreccias textures of the recrystallize wetterstein limestones from Tisovec. Marbles from Rákoš have variable colours. For the production of plastics are suitable streaked marbles from Lubeník. Positive results from the technological standpoint have locaties of carbonate rocks.

  19. AUGMENTATION-RELATED BRAIN PLASTICITY

    Directory of Open Access Journals (Sweden)

    Giovanni eDi Pino

    2014-06-01

    Full Text Available Today, the anthropomorphism of the tools and the development of neural interfaces require reconsidering the concept of human-tools interaction in the framework of human augmentation. This review analyzes the plastic process that the brain undergoes when it comes into contact with augmenting artificial sensors and effectors and, on the other hand, the changes that the use of external augmenting devices produces in the brain.Hitherto, few studies investigated the neural correlates of augmentation, but clues on it can be borrowed from logically-related paradigms: sensorimotor training, cognitive enhancement, cross-modal plasticity, sensorimotor functional substitution, use and embodiment of tools.Augmentation modifies function and structure of a number of areas, i.e. primary sensory cortices shape their receptive fields to become sensitive to novel inputs. Motor areas adapt the neuroprosthesis representation firing-rate to refine kinematics. As for normal motor outputs, the learning process recruits motor and premotor cortices and the acquisition of proficiency decreases attentional recruitment, focuses the activity on sensorimotor areas and increases the basal ganglia drive on the cortex. Augmentation deeply relies on the frontoparietal network. In particular, premotor cortex is involved in learning the control of an external effector and owns the tool motor representation, while the intraparietal sulcus extracts its visual features. In these areas, multisensory integration neurons enlarge their receptive fields to embody supernumerary limbs. For operating an anthropomorphic neuroprosthesis, the mirror system is required to understand the meaning of the action, the cerebellum for the formation of its internal model and the insula for its interoception. In conclusion, anthropomorphic sensorized devices can provide the critical sensory afferences to evolve the exploitation of tools through their embodiment, reshaping the body representation and the

  20. Comparison of seropositivity of human immunodeficiency virus, hepatitis B virus, hepatitis C virus, and syphilis among Hospital Cornea Retrieval Programme-Donors versus voluntary cornea donors at a large eye bank in Eastern India.

    Science.gov (United States)

    Basak, Soham; Basak, Samar K; Biswas, Bani

    2017-11-01

    To compare the serology profile of donors from Hospital Cornea Retrieval Programme-donors (HCRP-D) and voluntary cornea donors (VC-D) from a large eye bank in Eastern India. This is a retrospective analysis of donor details from January 2011 to December 2016. Donor demographics, cause of death, and serology reports were compiled. Postmortem blood was tested for human immunodeficiency virus 1 and 2 (HIV), hepatitis B virus (HBV), hepatitis C virus (HCV), and syphilis using government-approved kits as per the National Programme for Control of Blindness Standards of Eye Banking. Donors for whom serology was not possible were excluded. A total of 4300 of 4353 donors were included of which 74.3% were hospital donors and 25.7% were voluntary donors. A total of 93 (2.2%) donors with 94 seropositive reports were noted: 79 (84.9%) from HCRP-D and 14 (15.1%) from VC-D which was statistically significantly higher (P = 0.02). Among seropositive reports, HIV, HBV, HCV, and syphilis accounted for 12 (12.8%), 38 (40.4%), 36 (38.3%), and eight (8.5%), respectively. There was no correlation between the cause of death and seropositivity. A statistically significant decreasing trend in seroprevalence among hospital donors was observed over the years (5.3% in 2011 to 1.4% in 2016; P = 0.004). Two (0.47%) of 421 hospital donors with prior negative serology were found to be seropositive. Seropositive rates are significantly higher among hospital donors in spite of medical prescreening compared to nonscreened voluntary donors. Serology should be repeated even when prior reports are available.

  1. Plastic value chains

    DEFF Research Database (Denmark)

    Baxter, John; Wahlstrom, Margareta; Zu Castell-Rüdenhausen, Malin

    2014-01-01

    Optimizing plastic value chains is regarded as an important measure in order to increase recycling of plastics in an efficient way. This can also lead to improved awareness of the hazardous substances contained in plastic waste, and how to avoid that these substances are recycled. As an example......, plastics from WEEE is chosen as a Nordic case study. The project aims to propose a number of improvements for this value chain together with representatives from Nordic stakeholders. Based on the experiences made, a guide for other plastic value chains shall be developed....

  2. Our plastic age.

    Science.gov (United States)

    Thompson, Richard C; Swan, Shanna H; Moore, Charles J; vom Saal, Frederick S

    2009-07-27

    Within the last few decades, plastics have revolutionized our daily lives. Globally we use in excess of 260 million tonnes of plastic per annum, accounting for approximately 8 per cent of world oil production. In this Theme Issue of Philosophical Transactions of the Royal Society, we describe current and future trends in usage, together with the many benefits that plastics bring to society. At the same time, we examine the environmental consequences resulting from the accumulation of waste plastic, the effects of plastic debris on wildlife and concerns for human health that arise from the production, usage and disposal of plastics. Finally, we consider some possible solutions to these problems together with the research and policy priorities necessary for their implementation.

  3. Our plastic age

    Science.gov (United States)

    Thompson, Richard C.; Swan, Shanna H.; Moore, Charles J.; vom Saal, Frederick S.

    2009-01-01

    Within the last few decades, plastics have revolutionized our daily lives. Globally we use in excess of 260 million tonnes of plastic per annum, accounting for approximately 8 per cent of world oil production. In this Theme Issue of Philosophical Transactions of the Royal Society, we describe current and future trends in usage, together with the many benefits that plastics bring to society. At the same time, we examine the environmental consequences resulting from the accumulation of waste plastic, the effects of plastic debris on wildlife and concerns for human health that arise from the production, usage and disposal of plastics. Finally, we consider some possible solutions to these problems together with the research and policy priorities necessary for their implementation. PMID:19528049

  4. Visual outcomes after deep anterior lamellar keratoplasty using donor corneas without removal of Descemet membrane and endothelium

    Directory of Open Access Journals (Sweden)

    Tatiana Moura Bastos Prazeres

    Full Text Available ABSTRACT Purpose: The optical quality of the interface after deep anterior lamellar keratoplasty (DALK using the big-bubble technique has been shown to be excellent, leading to results comparable to penetrating keratoplasty. However, there is little in the literature with respect to the controversy surrounding the preparation of the donor cornea. The purpose of this study was to evaluate visual acuity (VA in patients with keratoconus who underwent DALK without removal of the donor graft endothelium. Methods: The records of 90 patients who underwent DALK without the removal of the Descemet membrane (DM and endothelium were retrospectively reviewed. Data collected included uncorrected VA (UCVA and spectacle-corrected VA (SCVA at 7, 30, 180 days, and 1 year postoperatively. Contact lens-corrected visual acuity (CLVA was evaluated after 1 year of the procedure. Results: UCVA was significantly better than preoperative values at 7 days (p<0.001, 30 days (p<0.001, 180 days (p<0.001, and 1 year (p<0.001 after surgery. The 1-year postoperative mean SCVA and CLVA also improved when compared with preoperative SCVA (p<0.001 for both. Conclusions: DALK utilizing donor corneas with attached Descemet membrane and endothelium results in satisfactory VA in patients with keratoconus.

  5. [Artificial organs].

    Science.gov (United States)

    Raguin, Thibaut; Dupret-Bories, Agnès; Debry, Christian

    2017-01-01

    Research has been fighting against organ failure and shortage of donations by supplying artificial organs for many years. With the raise of new technologies, tissue engineering and regenerative medicine, many organs can benefit of an artificial equivalent: thanks to retinal implants some blind people can visualize stimuli, an artificial heart can be proposed in case of cardiac failure while awaiting for a heart transplant, artificial larynx enables laryngectomy patients to an almost normal life, while the diabetic can get a glycemic self-regulation controlled by smartphones with an artificial device. Dialysis devices become portable, as well as the oxygenation systems for terminal respiratory failure. Bright prospects are being explored or might emerge in a near future. However, the retrospective assessment of putative side effects is not yet sufficient. Finally, the cost of these new devices is significant even if the advent of three dimensional printers may reduce it. © 2017 médecine/sciences – Inserm.

  6. Impact of Bio-Based Plastics on Current Recycling of Plastics

    Directory of Open Access Journals (Sweden)

    Luc Alaerts

    2018-05-01

    Full Text Available Bio-based plastics are increasingly appearing in a range of consumption products, and after use they often end up in technical recycling chains. Bio-based plastics are different from fossil-based ones and could disturb the current recycling of plastics and hence inhibit the closure of plastic cycles, which is undesirable given the current focus on a transition towards a circular economy. In this paper, this risk has been assessed via three elaborated case studies using data and information retrieved through an extended literature search. No overall risks were revealed for bio-based plastics as a group; rather, every bio-based plastic is to be considered as a potential separate source of contamination in current recycling practices. For PLA (polylactic acid, a severe incompatibility with PET (polyethylene terephthalate recycling is known; hence, future risks are assessed by measuring amounts of PLA ending up in PET waste streams. For PHA (polyhydroxy alkanoate there is no risk currently, but it will be crucial to monitor future application development. For PEF (polyethylene furanoate, a particular approach for contamination-related issues has been included in the upcoming market introduction. With respect to developing policy, it is important that any introduction of novel plastics is well guided from a system perspective and with a particular eye on incompatibilities with current and upcoming practices in the recycling of plastics.

  7. Polymicrobial Infection of the Cornea Due to Contact Lens Wear

    Directory of Open Access Journals (Sweden)

    Selçuk Sızmaz

    2016-04-01

    Full Text Available A 38-year-old male presented with pain and redness in his left eye. He had a history of wearing contact lenses. His ophthalmic examination revealed a large corneal ulcer with surrounding infiltrate. Cultures were isolated from the contact lenses, lens solutions, storage cases, and conjunctivae of both eyes and also corneal scrapings of the left eye. Fortified vancomycin and amikacin drops were started hourly. Culture results of conjunctivae of each eye and left cornea were positive for Pseudomonas aeruginosa; cultures from the contact lenses, lens solution and storage case of both eyes revealed Pseudomonas aeruginosa and Alcaligenes xylosoxidans. Polymerase chain reaction of the corneal scraping was positive for Acanthameoba. The topical antibiotics were changed with ones that both bacteria were sensitive to and anti-amoebic therapy was added. The patient had two recurrences following initial presentation despite intensive therapy. Keratitis occurred due to multiple pathogens; the relapsing course despite adequate therapy is potentially associated with this polymicrobial etiology.

  8. Coenzyme Q10 instilled as eye drops on the cornea reaches the retina and protects retinal layers from apoptosis in a mouse model of kainate-induced retinal damage.

    Science.gov (United States)

    Lulli, Matteo; Witort, Ewa; Papucci, Laura; Torre, Eugenio; Schipani, Christian; Bergamini, Christian; Dal Monte, Massimo; Capaccioli, Sergio

    2012-12-17

    To evaluate if coenzyme Q10 (CoQ10) can protect retinal ganglion cells (RGCs) from apoptosis and, when instilled as eye drops on the cornea, if it can reach the retina and exert its antiapoptotic activity in this area in a mouse model of kainate (KA)-induced retinal damage. Rat primary or cultured RGCs were subjected to glutamate (50 μM) or chemical hypoxia (Antimycin A, 200 μM) or serum withdrawal (FBS, 0.5%) in the presence or absence of CoQ10 (10 μM). Cell viability was evaluated by light microscopy and fluorescence-activated cell sorting analyses. Apoptosis was evaluated by caspase 3/7 activity and mitochondrion depolarization tetramethylrhodamine ethyl ester analysis. CoQ10 transfer to the retina following its instillation as eye drops on the cornea was quantified by HPLC. Retinal protection by CoQ10 (10 μM) eye drops instilled on the cornea was then evaluated in a mouse model of KA-induced excitotoxic retinal cell apoptosis by cleaved caspase 3 immunohistofluorescence, caspase 3/7 activity assays, and quantification of inhibition of RGC loss. CoQ10 significantly increased viable cells by preventing RGC apoptosis. Furthermore, when topically applied as eye drops to the cornea, it reached the retina, thus substantially increasing local CoQ10 concentration and protecting retinal layers from apoptosis. The ability of CoQ10 eye drops to protect retinal cells from apoptosis in the mouse model of KA-induced retinal damage suggests that topical CoQ10 may be evaluated in designing therapies for treating apoptosis-driven retinopathies.

  9. Plastic condoms.

    Science.gov (United States)

    1968-01-01

    Only simple equipment, simple technology and low initial capital investment are needed in their manufacture. The condoms can be made by people who were previously unskilled or only semi-skilled workers. Plastic condoms differ from those made of latex rubber in that the nature of the plastic film allows unlimited shelf-life. Also, the plastic has a higher degree of lubricity than latex rubber; if there is a demand for extra lubrication in a particular market, this can be provided. Because the plastic is inert, these condoms need not be packaged in hermetically sealed containers. All these attributes make it possible to put these condoms on the distributors' shelves in developing countries competitively with rubber condoms. The shape of the plastic condom is based on that of the lamb caecum, which has long been used as luxury-type condom. The plastic condom is made from plastic film (ethylene ethyl acrilate) of 0.001 inch (0.0254 mm.) thickness. In addition, a rubber ring is provided and sealed into the base of the condom for retention during coitus. The advantage of the plastic condom design and the equipment on which it is made is that production can be carried out either in labour-intensive economy or with varying degrees of mechanization and automation. The uniform, finished condom if made using previously untrained workers. Training of workers can be done in a matter of hours on the two machines which are needed to produce and test the condoms. The plastic film is provided on a double wound roll, and condom blanks are prepared by means of a heat-sealing die on the stamping machine. The rubber rings are united to the condom blanks on an assembly machine, which consists of a mandrel and heat-sealing equipment to seal the rubber ring to the base of the condom. Built into the assembly machine is a simple air-testing apparatus that can detect the smallest pinhole flaw in a condom. The manufacturing process is completed by unravelling the condom from the assembly

  10. Biodegradability of plastics.

    Science.gov (United States)

    Tokiwa, Yutaka; Calabia, Buenaventurada P; Ugwu, Charles U; Aiba, Seiichi

    2009-08-26

    Plastic is a broad name given to different polymers with high molecular weight, which can be degraded by various processes. However, considering their abundance in the environment and their specificity in attacking plastics, biodegradation of plastics by microorganisms and enzymes seems to be the most effective process. When plastics are used as substrates for microorganisms, evaluation of their biodegradability should not only be based on their chemical structure, but also on their physical properties (melting point, glass transition temperature, crystallinity, storage modulus etc.). In this review, microbial and enzymatic biodegradation of plastics and some factors that affect their biodegradability are discussed.

  11. Characterization of plastic blends made from mixed plastics waste of different sources.

    Science.gov (United States)

    Turku, Irina; Kärki, Timo; Rinne, Kimmo; Puurtinen, Ari

    2017-02-01

    This paper studies the recyclability of construction and household plastic waste collected from local landfills. Samples were processed from mixed plastic waste by injection moulding. In addition, blends of pure plastics, polypropylene and polyethylene were processed as a reference set. Reference samples with known plastic ratio were used as the calibration set for quantitative analysis of plastic fractions in recycled blends. The samples were tested for the tensile properties; scanning electron microscope-energy-dispersive X-ray spectroscopy was used for elemental analysis of the blend surfaces and Fourier transform infrared (FTIR) analysis was used for the quantification of plastics contents.

  12. The Prevalence of Cosmetic Facial Plastic Procedures among Facial Plastic Surgeons.

    Science.gov (United States)

    Moayer, Roxana; Sand, Jordan P; Han, Albert; Nabili, Vishad; Keller, Gregory S

    2018-04-01

    This is the first study to report on the prevalence of cosmetic facial plastic surgery use among facial plastic surgeons. The aim of this study is to determine the frequency with which facial plastic surgeons have cosmetic procedures themselves. A secondary aim is to determine whether trends in usage of cosmetic facial procedures among facial plastic surgeons are similar to that of nonsurgeons. The study design was an anonymous, five-question, Internet survey distributed via email set in a single academic institution. Board-certified members of the American Academy of Facial Plastic and Reconstructive Surgery (AAFPRS) were included in this study. Self-reported history of cosmetic facial plastic surgery or minimally invasive procedures were recorded. The survey also queried participants for demographic data. A total of 216 members of the AAFPRS responded to the questionnaire. Ninety percent of respondents were male ( n  = 192) and 10.3% were female ( n  = 22). Thirty-three percent of respondents were aged 31 to 40 years ( n  = 70), 25% were aged 41 to 50 years ( n  = 53), 21.4% were aged 51 to 60 years ( n  = 46), and 20.5% were older than 60 years ( n  = 44). Thirty-six percent of respondents had a surgical cosmetic facial procedure and 75% has at least one minimally invasive cosmetic facial procedure. Facial plastic surgeons are frequent users of cosmetic facial plastic surgery. This finding may be due to access, knowledge base, values, or attitudes. By better understanding surgeon attitudes toward facial plastic surgery, we can improve communication with patients and delivery of care. This study is a first step in understanding use of facial plastic procedures among facial plastic surgeons. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  13. Recycling of plastic waste: Presence of phthalates in plastics from households and industry.

    Science.gov (United States)

    Pivnenko, K; Eriksen, M K; Martín-Fernández, J A; Eriksson, E; Astrup, T F

    2016-08-01

    Plastics recycling has the potential to substitute virgin plastics partially as a source of raw materials in plastic product manufacturing. Plastic as a material may contain a variety of chemicals, some potentially hazardous. Phthalates, for instance, are a group of chemicals produced in large volumes and are commonly used as plasticisers in plastics manufacturing. Potential impacts on human health require restricted use in selected applications and a need for the closer monitoring of potential sources of human exposure. Although the presence of phthalates in a variety of plastics has been recognised, the influence of plastic recycling on phthalate content has been hypothesised but not well documented. In the present work we analysed selected phthalates (DMP, DEP, DPP, DiBP, DBP, BBzP, DEHP, DCHP and DnOP) in samples of waste plastics as well as recycled and virgin plastics. DBP, DiBP and DEHP had the highest frequency of detection in the samples analysed, with 360μg/g, 460μg/g and 2700μg/g as the maximum measured concentrations, respectively. Among other, statistical analysis of the analytical results suggested that phthalates were potentially added in the later stages of plastic product manufacturing (labelling, gluing, etc.) and were not removed following recycling of household waste plastics. Furthermore, DEHP was identified as a potential indicator for phthalate contamination of plastics. Close monitoring of plastics intended for phthalates-sensitive applications is recommended if recycled plastics are to be used as raw material in production. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Impact of artificial rearing systems on the developmental and reproductive fitness of the predatory bug, Orius laevigatus.

    Science.gov (United States)

    Bonte, Maarten; De Clercq, Patrick

    2010-01-01

    This study investigated the effect of several substrate types and moisture sources on the developmental and reproductive fitness of the zoophytophagous predator Orius laevigatus (Fieber) (Hemiptera: Anthocoridae) when fed a factitious prey (i.e. unnatural prey) Ephestia kuehniella (Zeller) eggs, or a meridic artificial diet based on hen's egg yolk. O. laevigatus is known to feed on plants as an alternative food source and to oviposit in plants. E. kuehniella eggs were superior to the artificial diet. Supplementary feeding on plant materials did not compensate for the nutritional shortcomings of the artificial diet. Survival rates showed that oviposition substrates such as bean pods or lipophilic surfaces such as wax paper and plastic were more suitable for rearing O. laevigatus than household paper. The use of green bean pods as a plant substrate did not have a beneficial effect on O. laevigatus. The results indicated that O. laevigatus can successfully complete its nymphal development and realize its full reproductive potential in the absence of plant material. However, plant materials would still be required for oviposition, unless a reliable and cost-effective artificial oviposition substrate were made available. The omission of plant materials from the rearing procedures may reduce production cost of this species and other heteropteran predators.

  15. Recycling of plastic waste: Presence of phthalates in plastics from households and industry

    DEFF Research Database (Denmark)

    Pivnenko, Kostyantyn; Eriksen, Marie Kampmann; Martín-Fernández, J. A.

    2016-01-01

    Plastics recycling has the potential to substitute virgin plastics partially as a source of raw materials in plastic product manufacturing. Plastic as a material may contain a variety of chemicals, some potentially hazardous. Phthalates, for instance, are a group of chemicals produced in large...... recognised, the influence of plastic recycling on phthalate content has been hypothesised but not well documented. In the present work we analysed selected phthalates (DMP, DEP, DPP, DiBP, DBP, BBzP, DEHP, DCHP and DnOP) in samples of waste plastics as well as recycled and virgin plastics. DBP, DiBP and DEHP...

  16. Biodegradability of Plastics

    Directory of Open Access Journals (Sweden)

    Yutaka Tokiwa

    2009-08-01

    Full Text Available Plastic is a broad name given to different polymers with high molecular weight, which can be degraded by various processes. However, considering their abundance in the environment and their specificity in attacking plastics, biodegradation of plastics by microorganisms and enzymes seems to be the most effective process. When plastics are used as substrates for microorganisms, evaluation of their biodegradability should not only be based on their chemical structure, but also on their physical properties (melting point, glass transition temperature, crystallinity, storage modulus etc.. In this review, microbial and enzymatic biodegradation of plastics and some factors that affect their biodegradability are discussed.

  17. Analysis of the effect of the fluid-structure interface on elastic wave velocity in cornea-like structures by OCE and FEM

    International Nuclear Information System (INIS)

    Han, Zhaolong; Li, Jiasong; Singh, Manmohan; Wu, Chen; Liu, Chih-hao; Raghunathan, Raksha; Larin, Kirill V; Vantipalli, Srilatha; Aglyamov, Salavat R; Twa, Michael D

    2016-01-01

    Air-pulse optical coherence elastography (OCE) is a promising technique for quantifying biomechanical properties of the cornea. This technique typically involves imaging and analysis of the propagation of the air-pulse induced elastic waves to reconstruct corneal biomechanical properties using an analytical model. However, the effect of the fluid-structure interface (FSI) at the corneal posterior surface on the elastic wave velocity is not accounted for in many models. In this study, we examined the effect of the FSI with OCE experiments on contact lenses with and without fluid in the posterior gap. Finite element models (FEM), also with and without the FSI, were constructed to simulate the elastic wave propagation based on the OCE measurements. The FEM and OCE results were in good agreement demonstrating the feasibility of the method. To further investigate the effect of the FSI, OCE experiments and subsequent FEM simulations were conducted on in situ rabbit corneas before and after rose bengal/green light corneal collagen cross-linking (RGX). Both the OCE experiments and the FE simulations demonstrated that the FSI significantly reduced the group velocity of the elastic wave, and thus, should be considered when determining corneal biomechanical properties from an appropriate mechanical model. By matching the FEM-calculated velocity to the OCE-measured velocity, the corneal elasticity was quantified. The Young’s modulus of the rabbit cornea before RGX was E  =  65  ±  10 kPa at a controlled intraocular pressure (IOP) of 15 mmHg. After RGX, the Young’s modulus increased to E  =  102  ±  7 kPa at the same IOP. (letter)

  18. Elastic-plastic behaviour of thick-walled containers considering plastic compressibility

    International Nuclear Information System (INIS)

    Betten, J.; Frosch, H.G.

    1983-01-01

    In this paper the elastic-plastic behaviour of thick-walled pressure vessels with internal and external pressure is studied. To describe the mechanical behaviour of isotropic, plastic compressible materials we use a plastic potential which is a single-valued function of the principle stresses. For cylinders and spheres an analytic expression for the computation of stresses and residual stresses is specified. Afterwards the strains are calculated by using the finite difference method. Some examples will high-light the influence of the plastic compressibility on the behaviour of pressure vessels. (orig.) [de

  19. Dynamical system with plastic self-organized velocity field as an alternative conceptual model of a cognitive system.

    Science.gov (United States)

    Janson, Natalia B; Marsden, Christopher J

    2017-12-05

    It is well known that architecturally the brain is a neural network, i.e. a collection of many relatively simple units coupled flexibly. However, it has been unclear how the possession of this architecture enables higher-level cognitive functions, which are unique to the brain. Here, we consider the brain from the viewpoint of dynamical systems theory and hypothesize that the unique feature of the brain, the self-organized plasticity of its architecture, could represent the means of enabling the self-organized plasticity of its velocity vector field. We propose that, conceptually, the principle of cognition could amount to the existence of appropriate rules governing self-organization of the velocity field of a dynamical system with an appropriate account of stimuli. To support this hypothesis, we propose a simple non-neuromorphic mathematical model with a plastic self-organized velocity field, which has no prototype in physical world. This system is shown to be capable of basic cognition, which is illustrated numerically and with musical data. Our conceptual model could provide an additional insight into the working principles of the brain. Moreover, hardware implementations of plastic velocity fields self-organizing according to various rules could pave the way to creating artificial intelligence of a novel type.

  20. Biomechanical responses of healthy and keratoconic corneas measured using a noncontact scheimpflug-based tonometer.

    Science.gov (United States)

    Ali, Noor Q; Patel, Dipika V; McGhee, Charles N J

    2014-05-15

    To examine the repeatability of measurements obtained using a noncontact Scheimpflug-based tonometer (Corvis ST) and investigate potential differences in these parameters between healthy and keratoconic (KC) corneas. Forty-five keratoconic eyes and 103 healthy eyes were examined using biomicroscopy, corneal tomography and the Corvis ST (CST). Intraocular pressure and central corneal thickness (CCT) were highly repeatable (intraclass correlation [ICC] > 0.70, coefficient of variation [CV] 0.60, CV < 0.20). There was no association between DA and age, sex, or ethnicity in healthy eyes. There was a greater mean DA in the KC group compared with 46 age-matched healthy eyes (KC 1.37 ± 0.21 mm, healthy 1.05 ± 0.11 mm, P < 0.001). Multivariate analysis showed DA in KC was predicted by IOP, CCT, and the steepest simulated keratometry value (P = 0.03, P = 0.03, P = 0.001 respectively, R(2) = 0.75). A subgroup analysis of healthy and KC eyes with comparable mean CCT and IOP highlighted a statistically significant difference in mean DA (KC 1.25 ± 0.08 mm, thin healthy 1.13 ± 0.09 mm, P = 0.006). Receiver-operating characteristic analysis showed an area under the curve of 0.77 (95% CI 0.61-0.93, P = 0.006) but no ideal cutoff value for DA. Key parameters assessed by the CST are repeatable. Keratoconus is associated with greater DA than in healthy eyes, even when controlled for CCT and IOP. Deformation amplitude may be a useful adjunct in keratoconus assessment and monitoring, but cannot solely discriminate between healthy and keratoconic corneas. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  1. Weather resistance of inkjet prints on plastic substrates

    Directory of Open Access Journals (Sweden)

    Rozália Szentgyörgyvölgyi

    2015-06-01

    Full Text Available The development of wide format inkjet printers made the technology available for large area commercials. Outdoor advertising uses a wide range of substrate including paperboard, vinyl, canvas, mesh; the material of the substrate itself has to endure the physical and chemical effects of local weather. Weather elements (humidity, wind, solar irradiation degrade printed products inevitably; plastic products have better resistance against them, than paper based substrates. Service life of the printed product for outdoor application is a key parameter from the customer’s point of view. There are two ways to estimate expected lifetime: on site outdoor testing or laboratory testing. In both cases weathering parameters can be monitored, however laboratory testing devices may produce the desired environmental effects and thus accelerate the aging process. Our research objective was to evaluate the effects of artificial weathering on prints produced by inkjet technology on plastic substrates. We used a large format CMYK inkjet printer (Mutoh Rockhopper II, with Epson DX 4 print heads to print our test chart on two similar substrates (PVC coated tarpaulins with grammages 400 g/m2 and 440 g/m2. Specimen were aged in an Atlas Suntest XLS+ material tester device for equal time intervals. We measured and calculated the gradual changes of the optical properties (optical density, tone value, colour shifts of the test prints.

  2. Mechanically equivalent elastic-plastic deformations and the problem of plastic spin

    Directory of Open Access Journals (Sweden)

    Steigmann David J.

    2011-01-01

    Full Text Available The problem of plastic spin is phrased in terms of a notion of mechanical equivalence among local intermediate configurations of an elastic/ plastic crystalline solid. This idea is used to show that, without further qualification, the plastic spin may be suppressed at the constitutive level. However, the spin is closely tied to an underlying undistorted crystal lattice which, once specified, eliminates the freedom afforded by mechanical equivalence. As a practical matter a constitutive specification of plastic spin is therefore required. Suppression of plastic spin thus emerges as merely one such specification among many. Restrictions on these are derived in the case of rate-independent response.

  3. Comparison of seropositivity of human immunodeficiency virus, hepatitis B virus, hepatitis C virus, and syphilis among Hospital Cornea Retrieval Programme-Donors versus voluntary cornea donors at a large eye bank in Eastern India

    Directory of Open Access Journals (Sweden)

    Soham Basak

    2017-01-01

    Full Text Available Purpose: To compare the serology profile of donors from Hospital Cornea Retrieval Programme-donors (HCRP-D and voluntary cornea donors (VC-D from a large eye bank in Eastern India. Methods: This is a retrospective analysis of donor details from January 2011 to December 2016. Donor demographics, cause of death, and serology reports were compiled. Postmortem blood was tested for human immunodeficiency virus 1 and 2 (HIV, hepatitis B virus (HBV, hepatitis C virus (HCV, and syphilis using government-approved kits as per the National Programme for Control of Blindness Standards of Eye Banking. Donors for whom serology was not possible were excluded. Results: A total of 4300 of 4353 donors were included of which 74.3% were hospital donors and 25.7% were voluntary donors. A total of 93 (2.2% donors with 94 seropositive reports were noted: 79 (84.9% from HCRP-D and 14 (15.1% from VC-D which was statistically significantly higher (P = 0.02. Among seropositive reports, HIV, HBV, HCV, and syphilis accounted for 12 (12.8%, 38 (40.4%, 36 (38.3%, and eight (8.5%, respectively. There was no correlation between the cause of death and seropositivity. A statistically significant decreasing trend in seroprevalence among hospital donors was observed over the years (5.3% in 2011 to 1.4% in 2016; P = 0.004. Two (0.47% of 421 hospital donors with prior negative serology were found to be seropositive. Conclusion: Seropositive rates are significantly higher among hospital donors in spite of medical prescreening compared to nonscreened voluntary donors. Serology should be repeated even when prior reports are available.

  4. Plastics and health risks.

    Science.gov (United States)

    Halden, Rolf U

    2010-01-01

    By 2010, the worldwide annual production of plastics will surpass 300 million tons. Plastics are indispensable materials in modern society, and many products manufactured from plastics are a boon to public health (e.g., disposable syringes, intravenous bags). However, plastics also pose health risks. Of principal concern are endocrine-disrupting properties, as triggered for example by bisphenol A and di-(2-ethylhexyl) phthalate (DEHP). Opinions on the safety of plastics vary widely, and despite more than five decades of research, scientific consensus on product safety is still elusive. This literature review summarizes information from more than 120 peer-reviewed publications on health effects of plastics and plasticizers in lab animals and humans. It examines problematic exposures of susceptible populations and also briefly summarizes adverse environmental impacts from plastic pollution. Ongoing efforts to steer human society toward resource conservation and sustainable consumption are discussed, including the concept of the 5 Rs--i.e., reduce, reuse, recycle, rethink, restrain--for minimizing pre- and postnatal exposures to potentially harmful components of plastics.

  5. Analysis of two precipitation methods on the yield, structural features and activity of sulfated polysaccharides from Gracilaria cornea (Rhodophyta

    Directory of Open Access Journals (Sweden)

    Ricardo Basto Souza

    2015-03-01

    Full Text Available The global demand for natural products from seaweeds has increased worldwide; however, no description of the use of isoamly alcohol (IAA for obtaining of sulfated polysaccharides (SPs has been reported. We investigated the efficiency of two precipitation methods (M in obtaining SPs from the red seaweed Gracilaria cornea. SPs enzymatically isolated were concentrated with cetylpyridinium chloride (M I or IAA (M II and extracts were examined with regard to their yield, structural features and in vitro effects on the activated partial thromboplastin time (APTT using normal human plasma and standard heparin (193 IU mg-1. Yield difference reached 12.99%. Quantitative determination of sulfate was similar between the two methods (̴ 26%, but extracts revealed different pattern on charge density by agarose gel electrophoresis. Whereas both extracts revealed as agarocolloids, alternative M II was also efficient for lipids, proteins and nucleic acids according to the infrared analysis. Extracts had virtually no effect on APPT (1.95 and 2 IU mg-1 for M I and M II, respectively. The results revealed IAA as an alternative solvent for obtaining SPs from the red seaweed G. cornea, depending on the industry’ usage criterion.

  6. Recycling of plastic waste: Presence of phthalates in plastics from households and industry

    DEFF Research Database (Denmark)

    Pivnenko, Kostyantyn; Eriksen, Marie Kampmann; Martín-Fernández, J. A.

    2016-01-01

    recognised, the influence of plastic recycling on phthalate content has been hypothesised but not well documented. In the present work we analysed selected phthalates (DMP, DEP, DPP, DiBP, DBP, BBzP, DEHP, DCHP and DnOP) in samples of waste plastics as well as recycled and virgin plastics. DBP, DiBP and DEHP...... product manufacturing (labelling, gluing, etc.) and were not removed following recycling of household waste plastics. Furthermore, DEHP was identified as a potential indicator for phthalate contamination of plastics. Close monitoring of plastics intended for phthalates-sensitive applications...

  7. Evaluation of Biomechanical Changes in Myopia Patients with Unsatisfactory Corneas After Femto Second-Laser In Situ Keratomileusis (FS-LASIK) Concurrent with Accelerated Corneal Collagen Cross-Linking Using Corvis-ST: Two-Year Follow-Up Results.

    Science.gov (United States)

    Xu, Weiwei; Tao, Ye; Wang, Liqiang; Huang, Yifei

    2017-07-27

    BACKGROUND Some myopia patients with unsatisfactory corneas consider corneal refractive surgery for different reasons. Accelerated corneal collagen crosslinking (ACXL) is an effective method to enhance the resistance of the cornea. The present investigation was designed to evaluate the changes of biomechanical properties in patients with myopia and thin corneas after femtosecond-laser in situ keratomileusis (FS-LASIK) concurrent with ACXL. MATERIAL AND METHODS A prospective study was designed. A total of 22 eyes of 11 myopia astigmatism patients with unsatisfactory corneas were enrolled. The patients were assigned to femtosecond-laser in situ keratomileusis concurrent with accelerated corneal collagen crosslinking (FS-LASIK-ACXL). The follow-up duration was 24 months. Manifest refraction, uncorrected (UDVA), and corrected distance visual acuity (CDVA), ultra-high-speed camera (Corvis-ST), corneal topography, anterior segment OCT (AS-OCT), Pentacam, and endothelial cell density (ECD) were examined before and after the operation. The corneal biomechanical and refractive data was analyzed using SAS9.3. Data were analyzed through normal distribution test and variance of analysis. The difference was considered as statistically significant when pLASIK-ACXL operation. The values of first applanation length (A1L), the second applanation length (A2L), the first applanation velocity (A1V), the second applanation velocity (A2V), deformation amplitude (DA), highest concavity peak distance (PD), and radius of curvature at the time of highest concavity (HCR) did not show significant difference after the operation. CONCLUSIONS FS-LASIK-ACXL is an effective and safe surgery for improving visual acuity for myopic patients with thin corneas, and it does not increase the risk of iatrogenic keratectasia.

  8. Challenges in plastics recycling

    DEFF Research Database (Denmark)

    Pivnenko, Kostyantyn; Jakobsen, L. G.; Eriksen, Marie Kampmann

    2015-01-01

    Recycling of waste plastics still remains a challenging area in the waste management sector. The current and potential goals proposed on EU or regional levels are difficult to achieve, and even to partially fullfil them the improvements in collection and sorting should be considerable. A study...... was undertaken to investigate the factors affecting quality in plastics recycling. The preliminary results showed factors primarily influencing quality of plastics recycling to be polymer cross contamination, presence of additives, non-polymer impurities, and polymer degradation. Deprivation of plastics quality......, with respect to recycling, has been shown to happen throughout the plastics value chain, but steps where improvements may happen have been preliminary identified. Example of Cr in plastic samples analysed showed potential spreading and accumulation of chemicals ending up in the waste plastics. In order...

  9. Artificial intelligence

    CERN Document Server

    Ennals, J R

    1987-01-01

    Artificial Intelligence: State of the Art Report is a two-part report consisting of the invited papers and the analysis. The editor first gives an introduction to the invited papers before presenting each paper and the analysis, and then concludes with the list of references related to the study. The invited papers explore the various aspects of artificial intelligence. The analysis part assesses the major advances in artificial intelligence and provides a balanced analysis of the state of the art in this field. The Bibliography compiles the most important published material on the subject of

  10. Individual differences in behavioural plasticities.

    Science.gov (United States)

    Stamps, Judy A

    2016-05-01

    Interest in individual differences in animal behavioural plasticities has surged in recent years, but research in this area has been hampered by semantic confusion as different investigators use the same terms (e.g. plasticity, flexibility, responsiveness) to refer to different phenomena. The first goal of this review is to suggest a framework for categorizing the many different types of behavioural plasticities, describe examples of each, and indicate why using reversibility as a criterion for categorizing behavioural plasticities is problematic. This framework is then used to address a number of timely questions about individual differences in behavioural plasticities. One set of questions concerns the experimental designs that can be used to study individual differences in various types of behavioural plasticities. Although within-individual designs are the default option for empirical studies of many types of behavioural plasticities, in some situations (e.g. when experience at an early age affects the behaviour expressed at subsequent ages), 'replicate individual' designs can provide useful insights into individual differences in behavioural plasticities. To date, researchers using within-individual and replicate individual designs have documented individual differences in all of the major categories of behavioural plasticities described herein. Another important question is whether and how different types of behavioural plasticities are related to one another. Currently there is empirical evidence that many behavioural plasticities [e.g. contextual plasticity, learning rates, IIV (intra-individual variability), endogenous plasticities, ontogenetic plasticities) can themselves vary as a function of experiences earlier in life, that is, many types of behavioural plasticity are themselves developmentally plastic. These findings support the assumption that differences among individuals in prior experiences may contribute to individual differences in behavioural

  11. Synaptic Plasticity and Learning Behaviors Mimicked in Single Inorganic Synapses of Pt/HfOx/ZnOx/TiN Memristive System

    Science.gov (United States)

    Wang, Lai-Guo; Zhang, Wei; Chen, Yan; Cao, Yan-Qiang; Li, Ai-Dong; Wu, Di

    2017-01-01

    In this work, a kind of new memristor with the simple structure of Pt/HfOx/ZnOx/TiN was fabricated completely via combination of thermal-atomic layer deposition (TALD) and plasma-enhanced ALD (PEALD). The synaptic plasticity and learning behaviors of Pt/HfOx/ZnOx/TiN memristive system have been investigated deeply. Multilevel resistance states are obtained by varying the programming voltage amplitudes during the pulse cycling. The device conductance can be continuously increased or decreased from cycle to cycle with better endurance characteristics up to about 3 × 103 cycles. Several essential synaptic functions are simultaneously achieved in such a single double-layer of HfOx/ZnOx device, including nonlinear transmission properties, such as long-term plasticity (LTP), short-term plasticity (STP), and spike-timing-dependent plasticity. The transformation from STP to LTP induced by repetitive pulse stimulation is confirmed in Pt/HfOx/ZnOx/TiN memristive device. Above all, simple structure of Pt/HfOx/ZnOx/TiN by ALD technique is a kind of promising memristor device for applications in artificial neural network.

  12. Durability of wood plastic composites manufactured from recycled plastic

    Directory of Open Access Journals (Sweden)

    Irina Turku

    2018-03-01

    Full Text Available The influence of accelerated weathering, xenon-arc light and freeze-thaw cycling on wood plastic composites extruded from a recycled plastic was studied. The results showed that, in general, weathering had a stronger impact on samples made from plastic waste compared to a sample made from virgin material. After weathering, the mechanical properties, tensile and flexural, were reduced by 2–30%, depending on the plastic source. Wettability of the samples was shown to play a significant role in their stability. Chemical analysis with infrared spectroscopy and surface observation with a scan electron microscope confirmed the mechanical test results. Incorporation of carbon black retained the properties during weathering, reducing the wettability of the sample, diminishing the change of mechanical properties, and improving color stability. Keywords: Environmental science, Mechanical engineering, Materials science

  13. Phenotypic plasticity, costs of phenotypes, and costs of plasticity

    DEFF Research Database (Denmark)

    Callahan, Hilary S; Maughan, Heather; Steiner, Uli

    2008-01-01

    Why are some traits constitutive and others inducible? The term costs often appears in work addressing this issue but may be ambiguously defined. This review distinguishes two conceptually distinct types of costs: phenotypic costs and plasticity costs. Phenotypic costs are assessed from patterns...... of covariation, typically between a focal trait and a separate trait relevant to fitness. Plasticity costs, separable from phenotypic costs, are gauged by comparing the fitness of genotypes with equivalent phenotypes within two environments but differing in plasticity and fitness. Subtleties associated with both...... types of costs are illustrated by a body of work addressing predator-induced plasticity. Such subtleties, and potential interplay between the two types of costs, have also been addressed, often in studies involving genetic model organisms. In some instances, investigators have pinpointed the mechanistic...

  14. Plastic waste as a resource. Strategies for reduction and utilization of plastic waste

    OpenAIRE

    Pasqual i Camprubí, Gemma

    2010-01-01

    Plastic materials have experienced a spectacular rate of growth in recent decades, consequently, production of plastics, and likewise their consumption, has increased markedly since 1950. Moreover, they are lightweight and durable, as well as can be moulded into a variety of products that can be manufactured in many different types of plastic and in a wide range of applications. Inevitably, continually increasing amounts of used plastic are originating daily, resulting in a plastic waste prob...

  15. Thermal degradation and plasticizing mechanism of poly(vinyl chloride) plasticized with a novel cardanol derived plasticizer

    Science.gov (United States)

    Chen, J.; Nie, X. A.; Jiang, J. C.; Zhou, Y. H.

    2018-01-01

    A natural plasticizer cardanol derivatives glycidyl ether (CGE) was synthesized and employed as a plasticizer for the poly(vinyl chloride). The effect of CGE on thermal degradation of PVC films and its plasticizing mechanism were firstly reported. The molecular structure of CGE was characterized with Fourier transform infrared spectroscopy (FTIR). Thermal properties, degradation properties and compatibility of the PVC films were investigated by Differential scanning calorimeter analysis (DSC), Thermogravimetric analysis (TGA) and FTIR, respectively. Compared with the commercial plasticizers dioctylphthalate (DOP), CGE can endow PVC film with a decrease of 4.31 °C in glass transition temperature (Tg), an increase of 24.01 °C and 25.53 °C in 10% weight loss (T 10) and 50% weight loss (T 50) respectively, and a higher activetion energy of thermal degradation (Ea ).

  16. Mixed plastics recycling technology

    CERN Document Server

    Hegberg, Bruce

    1995-01-01

    Presents an overview of mixed plastics recycling technology. In addition, it characterizes mixed plastics wastes and describes collection methods, costs, and markets for reprocessed plastics products.

  17. Sub-nanosecond plastic scintillators

    International Nuclear Information System (INIS)

    Lyons, P.B.; Caldwell, S.E.; Hocker, L.P.; Crandall, D.G.; Zagarino, P.A.; Cheng, J.; Tirsell, G.; Hurlbut, C.R.

    1977-01-01

    Quenched plastic scintillators have been developed that yield much faster short decay components and greatly reduced long decay components compared to conventional plastic scintillators. The plastics are produced through the addition of selected quench agents to NE111 plastic scintillator that result in reduced total light output. Eight different agents have been studied. Benzophenone and piperidine are two of the most effective quench agents. Data are presented both for short and long decay components. The plastics are expected to make significant contributions in areas of plasma diagnostics

  18. Sub-nanosecond plastic scintillators

    International Nuclear Information System (INIS)

    Lyons, P.B.; Caldwell, S.E.; Hocker, L.P.; Crandall, D.G.; Zagarino, P.A.; Cheng, J.; Tirsell, G.; Hurlbut, C.R.

    1976-01-01

    Quenched plastic scintillators have been developed that yield much faster short decay components and greatly reduced long decay components compared to conventional plastic scintillators. The plastics are produced through the addition of selected quench agents to NE111 plastic scintillator that result in reduced total light output. Eight different agents have been studied. Benzophenone and piperidine are two of the most effective quench agents. Data are presented both for short and long decay components. The plastics are expected to make significant contributions in areas of plasma diagnostics

  19. Coupled biomechanical response of the cornea assessed by non-contact tonometry. A simulation study.

    Directory of Open Access Journals (Sweden)

    Miguel Á Ariza-Gracia

    Full Text Available The mechanical response of the cornea subjected to a non-contact air-jet tonometry diagnostic test represents an interplay between its geometry, the corneal material behavior and the loading. The objective is to study this interplay to better understand and interpret the results obtained with a non-contact tonometry test. A patient-specific finite element model of a healthy eye, accounting for the load free configuration, was used. The corneal tissue was modeled as an anisotropic hyperelastic material with two preferential directions. Three different sets of parameters within the human experimental range obtained from inflation tests were considered. The influence of the IOP was studied by considering four pressure levels (10-28 mmHg whereas the influence of corneal thickness was studied by inducing a uniform variation (300-600 microns. A Computer Fluid Dynamics (CFD air-jet simulation determined pressure loading exerted on the anterior corneal surface. The maximum apex displacement showed a linear variation with IOP for all materials examined. On the contrary, the maximum apex displacement followed a cubic relation with corneal thickness. In addition, a significant sensitivity of the apical displacement to the corneal stiffness was also obtained. Explanation to this behavior was found in the fact that the cornea experiences bending when subjected to an air-puff loading, causing the anterior surface to work in compression whereas the posterior surface works in tension. Hence, collagen fibers located at the anterior surface do not contribute to load bearing. Non-contact tonometry devices give useful information that could be misleading since the corneal deformation is the result of the interaction between the mechanical properties, IOP, and geometry. Therefore, a non-contact tonometry test is not sufficient to evaluate their individual contribution and a complete in-vivo characterization would require more than one test to independently determine

  20. Collection, processing and testing of bone, corneas, umbilical cord blood and haematopoietic stem cells by European Blood Alliance members

    DEFF Research Database (Denmark)

    Närhi, M; Natri, O; Desbois, I

    2013-01-01

    A questionnaire study was carried out in collaboration with the European Blood Alliance (EBA) Tissues and Cells (T&C) working group. The aim was to assess the level of involvement and commonality of processes on the procurement, testing and storage of bone, corneas, umbilical cord blood (UCB......) and haematopoietic stem cells (HSC) in order to identify different practices and to explore whether recommendations can be made for harmonization....

  1. Time between plastic displacements of elasto-plastic oscillators subject to Gaussian white noise

    DEFF Research Database (Denmark)

    Tarp-Johansen, Niels Jacob; Ditlevsen, Ove Dalager

    2001-01-01

    A one degree of freedom elasto-plastic oscillator subject to stationary Gaussian white noise has a plastic displacement response process of intermittent character. During shorter or longer time intervals the oscillator vibrates within the elastic domain without undergoing any plastic displacements...... between the clumps of plastic displacements. This is needed for a complete description of the plastic displacement process. A quite accurate fast simulation procedure is presented based on an amplitude model to determine the short waiting times in the transient regime of the elastic vibrations existing...

  2. Artificial Leaf Based on Artificial Photosynthesis for Solar Fuel Production

    Science.gov (United States)

    2017-06-30

    collect light energy and separate charge for developing new types of nanobiodevices to construct ”artificial leaf” from solar to fuel. or Concept of...AFRL-AFOSR-JP-TR-2017-0054 Artificial Leaf Based on Artificial Photosynthesis for Solar Fuel Production Mamoru Nango NAGOYA INSTITUTE OF TECHNOLOGY...display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ORGANIZATION. 1. REPORT DATE (DD-MM-YYYY)      30-06-2017 2

  3. Artificial Neural Network Modelling of the Energy Content of Municipal Solid Wastes in Northern Nigeria

    Directory of Open Access Journals (Sweden)

    M. B. Oumarou

    2017-12-01

    Full Text Available The study presents an application of the artificial neural network model using the back propagation learning algorithm to predict the actual calorific value of the municipal solid waste in major cities of the northern part of Nigeria, with high population densities and intense industrial activities. These cities are: Kano, Damaturu, Dutse, Bauchi, Birnin Kebbi, Gusau, Maiduguri, Katsina and Sokoto. Experimental data of the energy content and the physical characterization of the municipal solid waste serve as the input parameter in nature of wood, grass, metal, plastic, food remnants, leaves, glass and paper. Comparative studies were made by using the developed model, the experimental results and a correlation which was earlier developed by the authors to predict the energy content. While predicting the actual calorific value, the maximum error was 0.94% for the artificial neural network model and 5.20% by the statistical correlation. The network with eight neurons and an R2 = 0.96881 in the hidden layer results in a stable and optimum network. This study showed that the artificial neural network approach could successfully be used for energy content predictions from the municipal solid wastes in Northern Nigeria and other areas of similar waste stream and composition.

  4. Uncertain Diagnosis of Fabry Disease in Patients with Neuropathic Pain, Angiokeratoma or Cornea Verticillata: Consensus on the Approach to Diagnosis and Follow-Up

    NARCIS (Netherlands)

    van der Tol, L.; Cassiman, David; Houge, Gunnar; Janssen, Mirian C.; Lachmann, Robin H.; Linthorst, Gabor E.; Ramaswami, Uma; Sommer, Claudia; Tøndel, Camilla; West, Michael L.; Weidemann, Frank; Wijburg, Frits A.; Svarstad, Einar; Hollak, Carla E. M.; Biegstraaten, Marieke

    2014-01-01

    Introduction: Individuals with neuropathic pain, angiokeratoma (AK) and/or cornea verticillata (CV) may be tested for Fabry disease (FD). Classical FD is characterised by a specific pattern of these features. When a patient presents with a non-specific pattern, the pathogenicity of a variant in the

  5. Uncertain diagnosis of fabry disease in patients with neuropathic pain, angiokeratoma or cornea verticillata: consensus on the approach to diagnosis and follow-up

    NARCIS (Netherlands)

    Tol, L. van der; Cassiman, D.; Houge, G.; Janssen, M.C.; Lachmann, R.H.; Linthorst, G.E.; Ramaswami, U.; Sommer, C.; Tondel, C.; West, M.L.; Weidemann, F.; Wijburg, F.A.; Svarstad, E.; Hollak, C.E.M.; Biegstraaten, M.

    2014-01-01

    INTRODUCTION: Individuals with neuropathic pain, angiokeratoma (AK) and/or cornea verticillata (CV) may be tested for Fabry disease (FD). Classical FD is characterised by a specific pattern of these features. When a patient presents with a non-specific pattern, the pathogenicity of a variant in the

  6. Beneficial effect of daidzin in dry eye rat model through the suppression of inflammation and oxidative stress in the cornea.

    Science.gov (United States)

    Xiao, Fan; Cui, Hua; Zhong, Xiao

    2018-05-01

    Present investigation evaluates the effect of daidzin in dry eye rat model through the suppression of inflammation and oxidative stress in the cornea. Briefly, electron spine resonance was used for the estimation of radical scavenging activity of daidzin and COX Fluorescent Activity Assay Kit was used for the estimation of PGS activity. Dry eye rat model was developed by removing the lacrimal gland and effect of daidzin was evaluated in dry eye rat model by estimating the fluorescein score, tear volume and expressions of heme oxigenase (HO-1), TNF α, Interlukin 6 (IL-6), matrix metallopeptidase 9 (MMP-9) and PGS-2. Result of the present study suggested that daidzin possess tyrosyl radical scavenging activity and thereby decreases the oxidative stress. Activity of PGS significantly increases in dry eye which was inhibited by daidzin treatment due to competitive inhibition of PGS. It also recovers the tear volume in dry eye rat model in which lacrimal gland was removed. Thus corneal erosion was improved by daidzin in dry eye rat model. Thus present study concludes that treatment with daidzin protects the cornea in dry eye rat model by suppression inflammation and oxidative stress.

  7. Effects produced by different types of laser in cornea of Guinea pigs: Identification of a laser capable of producing superficial lesions without leaving scars.

    Science.gov (United States)

    Suárez, A C; Suárez, M F; Crim, N; Monti, R; Urrets-Zavalía, J A; Serra, H M

    2015-10-01

    Climatic droplets keratopathy (CDK) is closely associated with superficial corneal erosions and lack of protective mechanisms against the harmful effects of ultraviolet radiation (UVR) during a prolonged period of time. One of the difficulties in studying the pathogenic mechanisms involved in this human disease is the lack of an experimental animal model. In this paper, a study is conducted on the effects of 4 types of lasers at various powers and time conditions on the normal guinea pig corneas in order to select only one laser condition that reversibly injures the epithelium and superficial stroma, without leaving scarring. Damage was induced in the cornea of Guinea pigs using different powers and exposure times of 4 types of laser: argon, CO2, diode and Nd-Yag, and any injuries were evaluated by biomicroscopy (BM) and optical microscopy. Corneas from other normal animals were exposed to argon laser (350 mW, 0.3s, 50 μm of diameter), and the induced alterations were studied at different times using BM, optical coherence tomography (OCT) and transmission electron microscopy (TEM). Only argon laser at 350 mW, 0.3s, 50 μm of diameter produced epithelium and superficial stroma lesions. Some leukomas were observed by BM, and they disappeared by day 15. Corneal thickness measured by OCT decreased in the eyes treated with argon laser during the first week. Using TEM, different ultra structural alterations in corneal epithelium and stroma were observed during the early days, which disappeared by day 15. It was possible to develop reproducible corneal epithelium and anterior stroma injuries using Argon laser at 350 mW, 0.3s, 50 μm of diameter. In vivo and in vitro studies showed that injured corneas with these laser conditions did not leave irreversible microscopic or ultra structural alterations. This protocol of corneal erosion combined with exposure to UVR and partial deficiency of ascorbate in the diets of the animals for an extended period of time has been used in

  8. [Application of biodegradable plastic film to reduce plastic film residual pollution in Chinese agriculture].

    Science.gov (United States)

    Yan, Changrong; He, Wenqing; Xue, Yinghao; Liu, Enke; Liu, Qin

    2016-06-25

    Plastic film has become an important agriculture production material in recent years. Over the past three decades, the amount and application area of plastic film have increased steadily, and in 2014, which are 1.4 million tons and more than 180 million hm² respectively. It plays a key role for ensuring the supply of agricultural goods in China. Meanwhile, plastic film residual pollution becomes more and more serious, and in some regions, the amount of plastic film residues has reached over 250 kg/hm². In part of the Northwest region, soil structure of farmland has been destroyed by plastic film residues and then crop growth and farming operations were suppressed. It is recognized as a good choice to replace plastic film with biodegradable plastic film, an effective measure to solve the plastic film residue pollution. Now, it is in a critical stage of study and assessment of biodegradable plastic film in China and fortunately some biodegradable plastic films show effects in the production of potatoes, peanuts and tobacco. Overall, a series of challenges has still been faced by the biodegradable plastic film, mainly including improving the quality of biodegradable plastic products, such as tensile strength, flexibility, improving the controllability of rupture and degradation, enhancing the ability of increasing soil temperature and preserving soil moisture, and to satisfy the demand of crops production with mulching. In addition, it is essential to reduce the cost of the biodegradable film and promote the application of biodegradable film on large-scale. With the development of biodegradable plastic technology and agricultural production environment, the application of the biodegradable film will have a good future.

  9. Biofiltration of fishpond effluents and accumulation of N-compounds (phycobiliproteins and mycosporine-like amino acids) versus C-compounds (polysaccharides) in Hydropuntia cornea (Rhodophyta)

    International Nuclear Information System (INIS)

    Figueroa, Félix L.; Korbee, Nathalie; Abdala, Roberto; Jerez, Celia G.; López-de la Torre, Mayra; Güenaga, Leire; Larrubia, María A.; Gómez-Pinchetti, Juan L.

    2012-01-01

    The biofiltration capacity, biomass-yield and accumulation of N- and C-compounds of Hydropuntia cornea were analyzed. Algae were grown in different conditions for 28 d: outdoor and indoor, with or without fishpond effluents. N-uptake efficiency of these effluents was higher than 95% after 7 d both outdoors and indoors. N-enriched conditions reduced the extent of photoinhibition and increased the maximal quantum yield in H. cornea. The biomass-yield was higher in outdoor grown-algae after 7 d and decreased independently of the treatment after 28 d. N, acid polysaccharide (AP) and mycosporine-like amino acid (MAA)-yields decreased throughout the experiment in all conditions. The highest MAA-yield was observed in fishpond effluent outdoor-grown algae, indicating a positive effect of increased radiation on MAA accumulation. However, APs were higher under N-depleted conditions. The use of MAAs as UV-screening and antioxidants, and the use of AP as immunostimulants are discussed.

  10. Biofiltration of fishpond effluents and accumulation of N-compounds (phycobiliproteins and mycosporine-like amino acids) versus C-compounds (polysaccharides) in Hydropuntia cornea (Rhodophyta).

    Science.gov (United States)

    Figueroa, Félix L; Korbee, Nathalie; Abdala, Roberto; Jerez, Celia G; López-de la Torre, Mayra; Güenaga, Leire; Larrubia, María A; Gómez-Pinchetti, Juan L

    2012-02-01

    The biofiltration capacity, biomass-yield and accumulation of N- and C-compounds of Hydropuntia cornea were analyzed. Algae were grown in different conditions for 28 d: outdoor and indoor, with or without fishpond effluents. N-uptake efficiency of these effluents was higher than 95% after 7 d both outdoors and indoors. N-enriched conditions reduced the extent of photoinhibition and increased the maximal quantum yield in H. cornea. The biomass-yield was higher in outdoor grown-algae after 7 d and decreased independently of the treatment after 28 d. N, acid polysaccharide (AP) and mycosporine-like amino acid (MAA)-yields decreased throughout the experiment in all conditions. The highest MAA-yield was observed in fishpond effluent outdoor-grown algae, indicating a positive effect of increased radiation on MAA accumulation. However, APs were higher under N-depleted conditions. The use of MAAs as UV-screening and antioxidants, and the use of AP as immunostimulants are discussed. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Optimisation of warpage on thin shell plastic part using response surface methodology (RSM) and glowworm swarm optimisation (GSO)

    Science.gov (United States)

    Asyirah, B. N.; Shayfull, Z.; Nasir, S. M.; Fathullah, M.; Hazwan, M. H. M.

    2017-09-01

    In manufacturing a variety of parts, plastic injection moulding is widely use. The injection moulding process parameters have played important role that affects the product's quality and productivity. There are many approaches in minimising the warpage ans shrinkage such as artificial neural network, genetic algorithm, glowworm swarm optimisation and hybrid approaches are addressed. In this paper, a systematic methodology for determining a warpage and shrinkage in injection moulding process especially in thin shell plastic parts are presented. To identify the effects of the machining parameters on the warpage and shrinkage value, response surface methodology is applied. In thos study, a part of electronic night lamp are chosen as the model. Firstly, experimental design were used to determine the injection parameters on warpage for different thickness value. The software used to analyse the warpage is Autodesk Moldflow Insight (AMI) 2012.

  12. Plastic fish

    CERN Multimedia

    Antonella Del Rosso

    2015-01-01

    In terms of weight, the plastic pollution in the world’s oceans is estimated to be around 300,000 tonnes. This plastic comes from both land-based and ocean-based sources. A lecture at CERN by chemist Wolfgang Trettnak addressed this issue and highlighted the role of art in raising people’s awareness.   Artwork by Wolfgang Trettnak. Packaging materials, consumer goods (shoes, kids’ toys, etc.), leftovers from fishing and aquaculture activities… our oceans and beaches are full of plastic litter. Most of the debris from beaches is plastic bottles. “PET bottles have high durability and stability,” explains Wolfgang Trettnak, a chemist by education and artist from Austria, who gave a lecture on this topic organised by the Staff Association at CERN on 26 May. “PET degrades very slowly and the estimated lifetime of a bottle is 450 years.” In addition to the beach litter accumulated from human use, rivers bring several ki...

  13. Generative Artificial Intelligence : Philosophy and Theory of Artificial Intelligence

    NARCIS (Netherlands)

    van der Zant, Tijn; Kouw, Matthijs; Schomaker, Lambertus; Mueller, Vincent C.

    2013-01-01

    The closed systems of contemporary Artificial Intelligence do not seem to lead to intelligent machines in the near future. What is needed are open-ended systems with non-linear properties in order to create interesting properties for the scaffolding of an artificial mind. Using post-structuralistic

  14. Plastics in the Marine Environment.

    Science.gov (United States)

    Law, Kara Lavender

    2017-01-03

    Plastics contamination in the marine environment was first reported nearly 50 years ago, less than two decades after the rise of commercial plastics production, when less than 50 million metric tons were produced per year. In 2014, global plastics production surpassed 300 million metric tons per year. Plastic debris has been detected worldwide in all major marine habitats, in sizes from microns to meters. In response, concerns about risks to marine wildlife upon exposure to the varied forms of plastic debris have increased, stimulating new research into the extent and consequences of plastics contamination in the marine environment. Here, I present a framework to evaluate the current understanding of the sources, distribution, fate, and impacts of marine plastics. Despite remaining knowledge gaps in mass budgeting and challenges in investigating ecological impacts, the increasing evidence of the ubiquity of plastics contamination in the marine environment, the continued rapid growth in plastics production, and the evidence-albeit limited-of demonstrated impacts to marine wildlife support immediate implementation of source-reducing measures to decrease the potential risks of plastics in the marine ecosystem.

  15. Plastics in the Marine Environment

    Science.gov (United States)

    Law, Kara Lavender

    2017-01-01

    Plastics contamination in the marine environment was first reported nearly 50 years ago, less than two decades after the rise of commercial plastics production, when less than 50 million metric tons were produced per year. In 2014, global plastics production surpassed 300 million metric tons per year. Plastic debris has been detected worldwide in all major marine habitats, in sizes from microns to meters. In response, concerns about risks to marine wildlife upon exposure to the varied forms of plastic debris have increased, stimulating new research into the extent and consequences of plastics contamination in the marine environment. Here, I present a framework to evaluate the current understanding of the sources, distribution, fate, and impacts of marine plastics. Despite remaining knowledge gaps in mass budgeting and challenges in investigating ecological impacts, the increasing evidence of the ubiquity of plastics contamination in the marine environment, the continued rapid growth in plastics production, and the evidence—albeit limited—of demonstrated impacts to marine wildlife support immediate implementation of source-reducing measures to decrease the potential risks of plastics in the marine ecosystem.

  16. Selection of polychlorinated plastics in plastic waste by X-ray fluorescence method

    International Nuclear Information System (INIS)

    Kumasaki, H.; Shinozaki, Y.

    1979-01-01

    The X-ray fluorescence method using a small source of 55 Fe was examined and found to be applicable for the selection of polychlorinated plastics from plastic waste in model areas in Tokyo designated for investigating their content in the waste. The weight ratios of soft and hard polychlorinated plastics to the total plastic waste estimated by this method were found to be 15.6% and 0.29% respectively. These values agree well with the results obtained with the Beilstein method. (author)

  17. Mast Cell Activation Protects Cornea by Promoting Neutrophil Infiltration via Stimulating ICAM-1 and Vascular Dilation in Fungal Keratitis.

    Science.gov (United States)

    Xie, Yanting; Zhang, Hongmin; Liu, Susu; Chen, Guoming; He, Siyu; Li, Zhijie; Wang, Liya

    2018-05-30

    The role of mast cells (MCs) in fungal infection is largely unknown. This study was to explore a protective role and mechanism of MCs in fungal keratitis. Experimental fungal keratitis (FK) mouse model was developed. Mice untreated (UT) or receiving corneal wound without fungal infection (Mock) were used as controls. Large number of connective tissue MCs was found in normal mice. MC activation with degranulation was largely observed, and the percentage of degranulated/total cells was high in FK. Dilated limbal vasculature with increased permeability, as well as largely infiltrated neutrophils with stimulated ICAM-1 protein levels were observed in corneas of FK mice, when compared with Mock and UT mice. Interestingly, pretreatment with cromolyn sodium (Block) significantly blocked MC degranulation, dramatically suppressed vascular dilation and permeability, and markedly reduced neutrophil infiltration with lower ICAM-1 levels in FK mice at 6-24 hours. Furthermore, the Block mice manifested prolonged disease course, increased pathological damage, and vigorous fungus growth, with much higher corneal perforation rate than FK mice at 72 h. These findings reveal a novel phenomenon that MCs play a vital role in protecting cornea against fungal infection through degranulation that promotes neutrophil infiltration via stimulating ICAM-1 production and limbal vascular dilation and permeability.

  18. Toxicological Threats of Plastic

    Science.gov (United States)

    Plastics pose both physical (e.g., entanglement, gastrointestinal blockage, reef destruction) and chemical threats (e.g., bioaccumulation of the chemical ingredients of plastic or toxic chemicals sorbed to plastics) to wildlife and the marine ecosystem.

  19. Plasticity of noddy parents and offspring to sea-surface temperature anomalies.

    Directory of Open Access Journals (Sweden)

    Carol A Devney

    Full Text Available Behavioral and/or developmental plasticity is crucial for resisting the impacts of environmental stressors. We investigated the plasticity of adult foraging behavior and chick development in an offshore foraging seabird, the black noddy (Anous minutus, during two breeding seasons. The first season had anomalously high sea-surface temperatures and 'low' prey availability, while the second was a season of below average sea-surface temperatures and 'normal' food availability. During the second season, supplementary feeding of chicks was used to manipulate offspring nutritional status in order to mimic conditions of high prey availability. When sea-surface temperatures were hotter than average, provisioning rates were significantly and negatively impacted at the day-to-day scale. Adults fed chicks during this low-food season smaller meals but at the same rate as chicks in the unfed treatment the following season. Supplementary feeding of chicks during the second season also resulted in delivery of smaller meals by adults, but did not influence feeding rate. Chick begging and parental responses to cessation of food supplementation suggested smaller meals fed to artificially supplemented chicks resulted from a decrease in chick demands associated with satiation, rather than adult behavioral responses to chick condition. During periods of low prey abundance, chicks maintained structural growth while sacrificing body condition and were unable to take advantage of periods of high prey abundance by increasing growth rates. These results suggest that this species expresses limited plasticity in provisioning behavior and offspring development. Consequently, responses to future changes in sea-surface temperature and other environmental variation may be limited.

  20. Plasticity and beyond microstructures, crystal-plasticity and phase transitions

    CERN Document Server

    Hackl, Klaus

    2014-01-01

    The book presents the latest findings in experimental plasticity, crystal plasticity, phase transitions, advanced mathematical modeling of finite plasticity and multi-scale modeling. The associated algorithmic treatment is mainly based on finite element formulations for standard (local approach) as well as for non-standard (non-local approach) continua and for pure macroscopic as well as for directly coupled two-scale boundary value problems. Applications in the area of material design/processing are covered, ranging from grain boundary effects in polycrystals and phase transitions to deep-drawing of multiphase steels by directly taking into account random microstructures.

  1. Vegetative and reproductive evaluation of hot peppers under different plastic mulches in poly/plastic tunnel

    International Nuclear Information System (INIS)

    Iqbal, Q.; Amjad, M.; Ahmad, R.

    2009-01-01

    Since the beginning of civilization, the man has developed technologies to increase the efficiency of food production. The use of plastic mulch in commercial vegetable production is one of these traditional techniques that have been used for centuries. Studies were conducted to assess the efficacy of plastic mulch on growth and yield of two hot pepper hybrids, viz. Sky Red and Maha in poly/plastic tunnel. The treatments were black plastic mulch, clear plastic mulch and bare soil as control. Both hot pepper hybrids mulched with black plastic showed significantly better vegetative growth (plant height, leaf area etc) and fruit yield. Clear plastic mulch significantly increased soil temperature and reduced the number of days to first flower than black plastic mulch and bare soil. However, fruit yield was higher by 39.56 and 36.49% respectively in both hybrids when they were grown on black and clear plastic mulch as compared to bare soil. Overall results indicated that the use of plastic mulch is an ideal option to maximize hot pepper productivity as well as to extend their production season in poly/plastic tunnels. (author)

  2. Denervation-induced homeostatic dendritic plasticity in morphological granule cell models

    Directory of Open Access Journals (Sweden)

    Hermann Cuntz

    2014-03-01

    Full Text Available Neuronal death and subsequent denervation of target areas are major consequences of several neurological conditions such asischemia or neurodegeneration (Alzheimer's disease. The denervation-induced axonal loss results in reorganization of the dendritic tree of denervated neurons. The dendritic reorganization has been previously studied using entorhinal cortex lesion (ECL. ECL leads to shortening and loss of dendritic segments in the denervated outer molecular layer of the dentate gyrus. However, the functional importance of these long-term dendritic alterations is not yet understood and their impact on neuronal electrical properties remains unclear. Here we analyzed what happens to the electrotonic structure and excitability of dentate granule cells after lesion-induced alterations of their dendritic morphology, assuming all other parameters remain equal. We performed comparative electrotonic analysis in anatomically and biophysically realistic compartmental models of 3D-reconstructed healthy and denervated granule cells. Using the method of morphological modeling based on optimization principles minimizing the amount of wiring and maximizing synaptic democracy, we built artificial granule cells which replicate morphological features of their real counterparts. Our results show that somatofugal and somatopetal voltage attenuation in the passive cable model are strongly reduced in denervated granule cells. In line with these predictions, the attenuation both of simulated backpropagating action potentials and forward propagating EPSPs was significantly reduced in dendrites of denervated neurons. Intriguingly, the enhancement of action potential backpropagation occurred specifically in the denervated dendritic layers. Furthermore, simulations of synaptic f-I curves revealed a homeostatic increase of excitability in denervated granule cells. In summary, our morphological and compartmental modeling indicates that unless modified by changes of

  3. Artificial life and Piaget.

    Science.gov (United States)

    Mueller, Ulrich; Grobman, K H.

    2003-04-01

    Artificial life provides important theoretical and methodological tools for the investigation of Piaget's developmental theory. This new method uses artificial neural networks to simulate living phenomena in a computer. A recent study by Parisi and Schlesinger suggests that artificial life might reinvigorate the Piagetian framework. We contrast artificial life with traditional cognitivist approaches, discuss the role of innateness in development, and examine the relation between physiological and psychological explanations of intelligent behaviour.

  4. Nanotechnology and regenerative therapeutics in plastic surgery: The next frontier

    Science.gov (United States)

    Tan, Aaron; Chawla, Reema; Natasha, G; Mahdibeiraghdar, Sara; Jeyaraj, Rebecca; Rajadas, Jayakumar; Hamblin, Michael R.; Seifalian, Alexander M.

    2015-01-01

    Summary The rapid ascent of nanotechnology and regenerative therapeutics as applied to medicine and surgery has seen an exponential rise in the scale of research generated in this field. This is evidenced not only by the sheer volume of papers dedicated to nanotechnology but also in a large number of new journals dedicated to nanotechnology and regenerative therapeutics specifically to medicine and surgery. Aspects of nanotechnology that have already brought benefits to these areas include advanced drug delivery platforms, molecular imaging and materials engineering for surgical implants. Particular areas of interest include nerve regeneration, burns and wound care, artificial skin with nanoelectronic sensors and head and neck surgery. This study presents a review of nanotechnology and regenerative therapeutics, with focus on its applications and implications in plastic surgery. PMID:26422652

  5. Preliminary study of sand jets in water-capped artificial and real MFT

    Energy Technology Data Exchange (ETDEWEB)

    Cai, J.; Zhu, D.; Rajaratnam, N. [Alberta Univ., Edmonton, AB (Canada). Dept. of Civil and Environmental Engineering

    2008-07-01

    A preliminary study of sand jets in water-capped artificial and real MFT was presented. Background information on oil sands tailing reclamation including water capping and sand capping were first discussed, followed by background information to the study, including non-Newtonian fluids and laponite clay, the artificial clay used mainly in small amounts as a rheology modifier in industrial fluids and materials. Although laponite clay is insoluble in water, it hydrates to make a clear and colourless colloidal, which is thixotropic and also behaves as a Bingham plastic fluid. The benefit of using gels made from laponite is the ability to see through to observe the physical processes in it. The objectives of the study were to examine the dynamics of sand jets in water-capped laponite gel and real MFT; improve the understanding of physical processes related to MFT and sand/slurry operations in tailings ponds; and find potential applications in recycling processed water and decommissioning of tailings ponds. It was concluded that it is much more difficult for jets to penetrate water-capped MFT due to larger yield stress in MFT. Future studies will focus on density correction, viscosity adjustment, and sensitivity analysis. tabs., figs.

  6. University students' knowledge of corneal donation and willingness to donate corneas in the occupied Palestinian territory: a cross-sectional study.

    Science.gov (United States)

    Al-Labadi, Liana; Gammoh, Yazan; Shehada, Reham; Shahin, Reem; Jbarah, Walaa; Amro, Madleen; Athamny, Hanan

    2018-02-21

    Access to corneal transplantation is limited worldwide because of poor knowledge. Ethical, religious, and cultural barriers contribute to low rates of corneal donation. In the occupied Palestinian territory, limited information is available on factors affecting corneal donation. The aim of this study was to assess the knowledge and willingness towards corneal donation in Palestinian students. This cross-sectional study included university students selected through convenience sampling in Nablus in the summer of 2016. The sample size was determined using the sample formulae and a 15% non-response rate. All students registered in obligatory courses were included in the study after verbal consent. Each participant was given a self-administered questionnaire consisting of 14 questions to assess knowledge, awareness, and willingness toward corneal donation. Frequencies were used for descriptive analysis, and associations were determined using multivariate analysis and χ 2 test, with a p value of less than 0·05 considered significant. Of the 634 students completing the questionnaire, 411 (65%) were women, 614 (97%) were Muslims, and 155 (25%) were health or medical students. 592 (93%) respondents were unaware of eye bank availability, and 407 (69%; p=0.002) of these respondents did not show willingness towards corneal donation. 431 (67%) respondents were aware of a lack in corneal donation, but 274 (64%; p=0·01) of these respondents did not show willingness towards corneal donation. 429 (68%) respondents were not willing to donate their corneas, the most common reasons being disapproval by family members and poor awareness. We found no association between sociodemographic factors and willingness was determined. Palestinian students are aware of the lack of local cornea donation but are unwilling to donate their corneas. The study results are not representative of the entire population because of the homogeneous nature of the sample. Large efforts are needed locally to

  7. Interaction between vegetable oil based plasticizer molecules and polyvinyl chloride, and their plasticization effect

    Science.gov (United States)

    Haryono, Agus; Triwulandari, Evi; Jiang, Pingping

    2017-01-01

    Plasticizer molecules are low molecular weight compounds that are widely used in polymer industries especially in polyvinyl chloride (PVC) resin. As an additive in PVC resin, the important role of plasticizer molecules is to improve the flexibility and processability of PVC by lowering the glass transition temperature (Tg). However, the commercial plasticizer like di(2-ethylhexyl)phthalate (DEHP) is known to cause liver cancer, at least in laboratory rats. DEHP can leach out from PVC into blood, certain drug solutions and fatty foods, which has been detected in the bloodstream of patients undergoing transfusion. Vegetable oil based plasticizers have some attractive properties such as non-toxic, bio-degradable, good heat and light stability, renewable resources, and environmentally friendly. Here we discussed the main results and development of vegetable oil based plasticizer, and especially palm oil based plasticizer. The interaction between plasticizer and polymer was discussed from the properties of the plasticized polymeric material.

  8. Quantitative & qualitative analysis of endothelial cells of donor cornea before & after penetrating keratoplasty in different pathological conditions

    Directory of Open Access Journals (Sweden)

    Aruna K.R. Gupta

    2016-01-01

    Full Text Available Background & objectives: Endothelial cells of the donor cornea are known to be affected quantitatively and qualitatively in different pathological conditions after penetrating keratoplasty (PK and this has direct effect on the clarity of vision obtained after PK. This study was undertaken to analyze the qualitative and quantitative changes in donor endothelial cells before and after PK in different pathological conditions. Methods: A prospective investigational analysis of 100 consecutive donor corneas used for penetrating keratoplasty between June 2006 and June 2008, was conducted. The patients were evaluated on the first day, at the end of first week, first month, third and six months and one year. Results: A decrease was observed in endothelial cell count in all pathological conditions. After one year of follow up the loss was 33.1 per cent in corneal opacity, 45.9 per cent in acute infective keratitis (AIK, 58.5 per cent in regrafts, 28.5 per cent in pseudophakic bullous keratopathy (PBK, 37 per cent in descemetocele, 27 per cent in keratoconus and 35.5 per cent in aphakic bullous keratopathy (ABK cases. Interpretation & conclusions: The endothelial cell loss was highest in regraft cases which was significant (P<0.05, while the least endothelial cell loss was seen in keratoconus cases. The cell loss was associated with increase in coefficient of variation (CV, i.e. polymegathism and pleomorphism. Inspite of this polymegathism and pleomorphism, the clarity of the graft was maintained.

  9. Short-term plasticity and long-term potentiation mimicked in single inorganic synapses

    Science.gov (United States)

    Ohno, Takeo; Hasegawa, Tsuyoshi; Tsuruoka, Tohru; Terabe, Kazuya; Gimzewski, James K.; Aono, Masakazu

    2011-08-01

    Memory is believed to occur in the human brain as a result of two types of synaptic plasticity: short-term plasticity (STP) and long-term potentiation (LTP; refs , , , ). In neuromorphic engineering, emulation of known neural behaviour has proven to be difficult to implement in software because of the highly complex interconnected nature of thought processes. Here we report the discovery of a Ag2S inorganic synapse, which emulates the synaptic functions of both STP and LTP characteristics through the use of input pulse repetition time. The structure known as an atomic switch, operating at critical voltages, stores information as STP with a spontaneous decay of conductance level in response to intermittent input stimuli, whereas frequent stimulation results in a transition to LTP. The Ag2S inorganic synapse has interesting characteristics with analogies to an individual biological synapse, and achieves dynamic memorization in a single device without the need of external preprogramming. A psychological model related to the process of memorizing and forgetting is also demonstrated using the inorganic synapses. Our Ag2S element indicates a breakthrough in mimicking synaptic behaviour essential for the further creation of artificial neural systems that emulate characteristics of human memory.

  10. A 2-transistor/1-resistor artificial synapse capable of communication and stochastic learning in neuromorphic systems.

    Science.gov (United States)

    Wang, Zhongqiang; Ambrogio, Stefano; Balatti, Simone; Ielmini, Daniele

    2014-01-01

    Resistive (or memristive) switching devices based on metal oxides find applications in memory, logic and neuromorphic computing systems. Their small area, low power operation, and high functionality meet the challenges of brain-inspired computing aiming at achieving a huge density of active connections (synapses) with low operation power. This work presents a new artificial synapse scheme, consisting of a memristive switch connected to 2 transistors responsible for gating the communication and learning operations. Spike timing dependent plasticity (STDP) is achieved through appropriate shaping of the pre-synaptic and the post synaptic spikes. Experiments with integrated artificial synapses demonstrate STDP with stochastic behavior due to (i) the natural variability of set/reset processes in the nanoscale switch, and (ii) the different response of the switch to a given stimulus depending on the initial state. Experimental results are confirmed by model-based simulations of the memristive switching. Finally, system-level simulations of a 2-layer neural network and a simplified STDP model show random learning and recognition of patterns.

  11. VIP and VIP gene silencing modulation of differentiation marker N-cadherin and cell shape of corneal endothelium in human corneas ex vivo.

    Science.gov (United States)

    Koh, Shay-Whey M; Chandrasekara, Krish; Abbondandolo, Cara J; Coll, Timothy J; Rutzen, Allan R

    2008-08-01

    Vasoactive intestinal peptide (VIP) is expressed by corneal endothelial (CE) cells and is present in the aqueous humor, which bathes CE cells in vivo. This study demonstrated the role of CE cell VIP in maintaining the expression level of a CE differentiation marker, N-cadherin, and the hexagonal cell shape. To determine the most effective VIP concentration, bovine corneoscleral explants were treated with 0 (control) and 10(-12) to 10(-6) M VIP. Paired human corneas (nine donors) from an eye bank were used as control; the other corneas were treated with VIP. To silence endogenous VIP, paired fresh human donor corneas (from seven cadavers) were transduced with VIP shRNA or the control lentiviral particles and then bisected/quartered for quantitative analysis by semiquantitative RT-PCR (for mRNA) and Western blot analysis/immunocytochemistry (for protein), whereas alizarin red S staining revealed CE cell shape. VIP concentration dependently increased bovine CE cell N-cadherin mRNA levels, with the maximal effect observed between 10(-10) (1.47 +/- 0.06-fold; P = 0.002) and 10(-8) M VIP (1.48 +/- 0.18-fold; P = 0.012). VIP (10(-8) M) treatment increased N-cadherin protein levels in bovine and human CE cells to 1.98 +/- 0.28-fold (P = 0.005) and 1.17 +/- 0.10 (range, 0.91-1.87)-fold (P = 0.050) of their respective controls. VIP antagonist (SN)VIPhyb diminished the VIP effect. VIP silencing resulted in deterioration of the hexagonal cell shape and decreased levels of VIP protein and mRNA, N-cadherin (but not connexin-43) mRNA and protein, and the antiapoptotic Bcl-2 protein. Through its autocrine VIP, CE cells play an active role in maintaining the differentiated state and suppressing apoptosis in the corneal endothelium in situ.

  12. Handbook of Plastic Welding

    DEFF Research Database (Denmark)

    Islam, Aminul

    The purpose of this document is to summarize the information about the laser welding of plastic. Laser welding is a matured process nevertheless laser welding of micro dimensional plastic parts is still a big challenge. This report collects the latest information about the laser welding of plastic...... materials and provides an extensive knowhow on the industrial plastic welding process. The objectives of the report include: - Provide the general knowhow of laser welding for the beginners - Summarize the state-of-the-art information on the laser welding of plastics - Find the technological limits in terms...... of design, materials and process - Find the best technology, process and machines adaptive to Sonion’s components - Provide the skills to Sonion’s Design Engineers for successful design of the of the plastic components suitable for the laser welding The ultimate goal of this report is to serve...

  13. Abiotic degradation of plastic films

    Science.gov (United States)

    Ángeles-López, Y. G.; Gutiérrez-Mayen, A. M.; Velasco-Pérez, M.; Beltrán-Villavicencio, M.; Vázquez-Morillas, A.; Cano-Blanco, M.

    2017-01-01

    Degradable plastics have been promoted as an option to mitigate the environmental impacts of plastic waste. However, there is no certainty about its degradability under different environmental conditions. The effect of accelerated weathering (AW), natural weathering (NW) and thermal oxidation (TO) on different plastics (high density polyethylene, HDPE; oxodegradable high density polyethylene, HDPE-oxo; compostable plastic, Ecovio ® metalized polypropylene, PP; and oxodegradable metalized polypropylene, PP-oxo) was studied. Plastics films were exposed to AW per 110 hours; to NW per 90 days; and to TO per 30 days. Plastic films exposed to AW and NW showed a general loss on mechanical properties. The highest reduction in elongation at break on AW occurred to HDPE-oxo (from 400.4% to 20.9%) and was higher than 90% for HDPE, HDPE-oxo, Ecovio ® and PP-oxo in NW. No substantial evidence of degradation was found on plastics exposed to TO. Oxo-plastics showed higher degradation rates than their conventional counterparts, and the compostable plastic was resistant to degradation in the studied abiotic conditions. This study shows that degradation of plastics in real life conditions will vary depending in both, their composition and the environment.

  14. Plasticity characteristic obtained by indentation

    International Nuclear Information System (INIS)

    Mil'man, Yu.V.; Chugunova, S.I.; Goncharova, I.V.

    2011-01-01

    Methods for determination plasticity characteristic δH in the measurement of hardness and nanohardness are considered. Parameter δH characterizes the plasticity of a material by the part of plastic deformation in the total elastic-plastic deformation. The value of δH is defined for metals with different types of crystal lattice, covalent and partially covalent crystals, intermetallics, metallic glasses and quasicrystals. It is discussed the dependence of the plasticity characteristic δH on structural factors and temperature. Parameter δH allows to analyze and compare the plasticity of materials which are brittle at standard mechanical tests. The combination of hardness H, as the strength characteristic, and the plasticity characteristic δH makes possible the better characterization of mechanical behavior of materials than only the hardness H. The examples of plasticity characteristic δH application are represented.

  15. Experiments with elasto-plastic oscillator

    DEFF Research Database (Denmark)

    Randrup-thomsen, Søren; Ditlevsen, Ove Dalager

    1996-01-01

    Plastic displacements of a Gaussian white noise excited three degrees of freedom non-ideal elasto-plastic oscillator are measured in laboratory experiments and the plastic displacements are compared to computer simulated results for the corresponding ideal elasto-plastic oscillator. The comparative...

  16. Experiments with elasto-plastic oscillator

    DEFF Research Database (Denmark)

    Randrup-Thomsen, S.; Ditlevsen, Ove Dalager

    1999-01-01

    Plastic displacements of a Gaussian white noise excited three degrees of freedom non-ideal elasto-plastic oscillator are measured in laboratory experiments and the plastic displacements are compared to computer simulated results for the corresponding ideal elasto-plastic oscillator. The comparative...

  17. Artificial sweeteners

    DEFF Research Database (Denmark)

    Raben, Anne Birgitte; Richelsen, Bjørn

    2012-01-01

    Artificial sweeteners can be a helpful tool to reduce energy intake and body weight and thereby risk for diabetes and cardiovascular diseases (CVD). Considering the prevailing diabesity (obesity and diabetes) epidemic, this can, therefore, be an important alternative to natural, calorie-containin......Artificial sweeteners can be a helpful tool to reduce energy intake and body weight and thereby risk for diabetes and cardiovascular diseases (CVD). Considering the prevailing diabesity (obesity and diabetes) epidemic, this can, therefore, be an important alternative to natural, calorie......-containing sweeteners. The purpose of this review is to summarize the current evidence on the effect of artificial sweeteners on body weight, appetite, and risk markers for diabetes and CVD in humans....

  18. ENVIRONMENTAL ISSUE-PLASTIC

    OpenAIRE

    Sunita Shakle

    2017-01-01

    Polythene is the most common plastic, the annual global production is approximately 60 million tones, and its primary use is in packing. Plastic bags pollute soil and waters and kill thousands of marine generalize plastic bags are not biodegradable they clog water ways, spoil the land scape and end up in landfills. Where they may take 1000 year or more to break down into ever smaller particals that continue to pollution the soil and water.

  19. Artificial cognition architectures

    CERN Document Server

    Crowder, James A; Friess, Shelli A

    2013-01-01

    The goal of this book is to establish the foundation, principles, theory, and concepts that are the backbone of real, autonomous Artificial Intelligence. Presented here are some basic human intelligence concepts framed for Artificial Intelligence systems. These include concepts like Metacognition and Metamemory, along with architectural constructs for Artificial Intelligence versions of human brain functions like the prefrontal cortex. Also presented are possible hardware and software architectures that lend themselves to learning, reasoning, and self-evolution

  20. Nano-Ceramic Coated Plastics

    Science.gov (United States)

    Cho, Junghyun

    2013-01-01

    Plastic products, due to their durability, safety, and low manufacturing cost, are now rapidly replacing cookware items traditionally made of glass and ceramics. Despite this trend, some still prefer relatively expensive and more fragile ceramic/glassware because plastics can deteriorate over time after exposure to foods, which can generate odors, bad appearance, and/or color change. Nano-ceramic coatings can eliminate these drawbacks while still retaining the advantages of the plastic, since the coating only alters the surface of the plastic. The surface coating adds functionality to the plastics such as self-cleaning and disinfectant capabilities that result from a photocatalytic effect of certain ceramic systems. These ceramic coatings can also provide non-stick surfaces and higher temperature capabilities for the base plastics without resorting to ceramic or glass materials. Titanium dioxide (TiO2) and zinc oxide (ZnO) are the candidates for a nano-ceramic coating to deposit on the plastics or plastic films used in cookware and kitchenware. Both are wide-bandgap semiconductors (3.0 to 3.2 eV for TiO2 and 3.2 to 3.3 eV for ZnO), so they exhibit a photocatalytic property under ultraviolet (UV) light. This will lead to decomposition of organic compounds. Decomposed products can be easily washed off by water, so the use of detergents will be minimal. High-crystalline film with large surface area for the reaction is essential to guarantee good photocatalytic performance of these oxides. Low-temperature processing (nano-ceramic coatings (TiO2, ZnO) on plastic materials (silicone, Teflon, PET, etc.) that can possess both photocatalytic oxide properties and flexible plastic properties. Processing cost is low and it does not require any expensive equipment investment. Processing can be scalable to current manufacturing infrastructure.

  1. Conhecimento de estudantes de medicina sobre o processo de doação de córneas The knowledge of medical students about cornea donation

    Directory of Open Access Journals (Sweden)

    Rodrigo França de Espíndola

    2007-08-01

    Full Text Available OBJETIVO: Avaliar o conhecimento de estudantes de medicina sobre o processo de doação de córneas, comparando-o entre aqueles que já cursaram a disciplina de Oftalmologia com os demais. MÉTODOS: Foi aplicado um questionário a estudantes de medicina do interior de São Paulo, contendo dados como: idade, sexo, ano de graduação e 10 perguntas de múltipla escolha sobre o tema. As questões abordaram o limite de idade para doação, contra-indicações para o transplante, tempo para retirada das córneas, dentre outras. Foi comparado o conhecimento (% de acertos entre aqueles que haviam cursado a disciplina de Oftalmologia (Grupo A com os demais (Grupo B. RESULTADOS: Foram entrevistados 402 estudantes. Destes, 140 eram do grupo A e 262 do grupo B. Não houve diferença estatisticamente significante entre os dois grupos (p=0,8328. CONCLUSÃO: O conhecimento sobre o processo de doação de córneas mostrou-se insuficiente entre os alunos entrevistados, mesmo para aqueles que haviam cursado a disciplina de Oftalmologia, apontando a necessidade de aperfeiçoamento do conhecimento divulgado nas escolas médicas.PURPOSE: To compare knowledge of medical students about the cornea donation process among those who already studied Ophthalmology and the others. METHODOS: A questionnaire containing data as: age, sex, graduation year, and 10 multiple-choice questions about the subject was applied to medical students from the interior of São Paulo state, Brazil. The questions were: age for donation, contraindication for transplants, the time limit to remove the cornea, among others. The knowledge regarding cornea donation was compared between the two groups: students who already studied Ophthalmology (Group A and the others (Group B. RESULTS: The study group was composed of 402 students, of whom 140 were of group A and 262 of group B. Knowledge between the two groups was different, but not statistically significant (p=0.8328. CONCLUSION: Knowledge about

  2. Elastic-plastic analysis of AS4/PEEK composite laminate using a one-parameter plasticity model

    Science.gov (United States)

    Sun, C. T.; Yoon, K. J.

    1992-01-01

    A one-parameter plasticity model was shown to adequately describe the plastic deformation of AS4/PEEK (APC-2) unidirectional thermoplastic composite. This model was verified further for unidirectional and laminated composite panels with and without a hole. The elastic-plastic stress-strain relations of coupon specimens were measured and compared with those predicted by the finite element analysis using the one-parameter plasticity model. The results show that the one-parameter plasticity model is suitable for the analysis of elastic-plastic deformation of AS4/PEEK composite laminates.

  3. Performance of molded plastic scintillators

    International Nuclear Information System (INIS)

    Gen, N.S.; Leman, V.E.; Solomonov, V.M.

    1989-01-01

    The performance of molded plastic scintillators is studied. The plastic scintillators studied were formed by transfer molding and intrusion from a scintillation composition consisting of polystyrene and a standard system of luminescent additives: 2 mass % of paraterphenyl + 0.06 mass % 1,4-di-/2-[5-phenyloxazoyly]/benzene and a plasticizer. The combined effect of mechanical load and temperature was studied. The effect of radiation on molded plastic scintillators was studied using gamma radiation from a 60 Co source. The studies show that the main operating characteristics of molded plastic scintillators are on a par with those of polymerized plastic scintillators. At the same time, molded plastic scintillators are superior in thermal stability at temperatures below the glass transition temperature and with respect to their working temperature range

  4. Plastic food packaging and health

    Directory of Open Access Journals (Sweden)

    Raika Durusoy

    2011-02-01

    Full Text Available Plastics have a wide usage in our daily lives. One of their uses is for food packaging and food containers. The aim of this review is to introduce different types of chemicals that can leach from food packaging plastics into foods and cause human exposure and to mention their effects on health. The types of plastics were reviewed under the 13 headings in Turkish Codex Alimentarius and plastics recycling symbols were provided to enable the recognition of the type of plastic when applicable. Chemicals used during the production and that can cause health risks are investigated under the heading of the relevant type of plastic. The most important chemicals from plastic food packaging that can cause toxicity are styrene, 1,3-butadiene, melamine, formaldehyde, acrylamide, di-2-ethylhexyl phthalate, di-2-ethylhexyl adipate, vinyl chloride and bisphenol A. These chemicals have endocrine disrupting, carcinogenic and/or development disrupting effects. These chemicals may leach into foods depending on the chemical properties of the plastic or food, temperature during packaging, processing and storage, exposure to UV and duration of storage. Contact with fatty/oily or acidic foods, heating of the food inside the container, or drinking hot drinks from plastic cups, use of old and scratched plastics and some detergents increase the risk of leaching. The use of plastic containers and packaging for food and beveradges should be avoided whenever possible and when necessary, less harmful types of plastic should be preferred. [TAF Prev Med Bull 2011; 10(1.000: 87-96

  5. One cornea for two patients: case report Uma córnea para dois pacientes: relato de caso

    Directory of Open Access Journals (Sweden)

    Ljubisa Nikolic

    2010-06-01

    Full Text Available Case reporting the use of one donor cornea for two transplantation procedures: deep anterior lamellar keratoplasty (DALK in a case of an imminent corneal perforation caused by herpetic stromal necrosis, and Descemet stripping with endothelial keratoplasty (DSEK in an eye with pseudophakic bullous keratopathy (PBK. Descemet's membrane (DM, denuded by stromal necrosis, served as the starting point for dissection plane and creation of the recipient bed for DALK. The next steps were excision of the diseased stroma along the edge of trephination, and transplantation of a 400-450 µm thick, manually dissected lamellar graft. The remaining posterior layers of the donor cornea, 100-150 µm thick, were used as a graft in the DSEK procedure for PBK. The integrity of the globe was saved, and best-corrected visual acuity (BCVA of 20/40 was reached after DALK in the eye with an imminent corneal perforation. A subnormal central corneal thickness (CCT of 430 µm did not interfere with corneal shape (43.50 x 45.50 D and function. The graft remained attached and clear after DSEK in the eye with PBK, with BCVA of 20/30 and a CCT of 653 µm. One donor cornea can be used for two lamellar keratoplasties, DALK and DSEK. Although the described obstacles may prevent this approach from becoming widely used, it may prove useful when one is confronted with a need for an urgent anterior lamellar keratoplasty, a long list of cases for DSEK, and a shortage of donor corneas.Relato de caso descrevendo o uso de uma córnea doadora para dois procedimentos de transplante: ceratoplastia anterior lamelar profunda (DALK no caso de uma perfuração corneal iminente causada por necrose estromal por herpes vírus, e ceratoplastia com transplante de endotélio (DSEK no olho com ceratopatia bolhosa em pseudofacia (PBK. A membrana de Descemet (DM, previamente desnudada pela necrose estromal, serviu como ponto de partida para o plano de dissecção e da criação do leito estromal para

  6. Our plastic age

    OpenAIRE

    Thompson, Richard C.; Swan, Shanna H.; Moore, Charles J.; vom Saal, Frederick S.

    2009-01-01

    Within the last few decades, plastics have revolutionized our daily lives. Globally we use in excess of 260 million tonnes of plastic per annum, accounting for approximately 8 per cent of world oil production. In this Theme Issue of Philosophical Transactions of the Royal Society, we describe current and future trends in usage, together with the many benefits that plastics bring to society. At the same time, we examine the environmental consequences resulting from the accumulation of waste pl...

  7. A Conservative Formulation for Plasticity

    Science.gov (United States)

    1992-01-01

    concepts that apply to a broad class of macroscopic models: plastic deformation and plastic flow rule. CONSERVATIVE PLASTICITY 469 3a. Plastic Defrrnation...temperature. We illustrate these concepts with a model that has been used to describe high strain-rate plastic flow in metals [11, 31, 32]. In the case...JOURDREN, AND P. VEYSSEYRE. Un Modele ttyperelastique- Plastique Euldrien Applicable aux Grandes Dtformations: Que/ques R~sultats 1-D. preprint, 1991. 2. P

  8. Artificial Disc Replacement

    Science.gov (United States)

    ... Spondylolisthesis BLOG FIND A SPECIALIST Treatments Artificial Disc Replacement (ADR) Patient Education Committee Jamie Baisden The disc ... Disc An artificial disc (also called a disc replacement, disc prosthesis or spine arthroplasty device) is a ...

  9. Wood-plastic combination

    International Nuclear Information System (INIS)

    Schaudy, R.

    1978-02-01

    A review on wood-plastic combinations is given including the production (wood and plastic component, radiation hardening, curing), the obtained properties, present applications and prospects for the future of these materials. (author)

  10. Plastic deformation and contact area of an elastic-plastic contact of ellipsoid bodies after unloading

    NARCIS (Netherlands)

    Jamari, Jamari; Schipper, Dirk J.

    2007-01-01

    This paper presents theoretical and experimental results of the residual or plastic deformation and the plastic contact area of an elastic–plastic contact of ellipsoid bodies after unloading. There are three regime responses of the deformation and contact area: elastic, elastic–plastic and fully

  11. Artificial life and life artificialization in Tron

    Directory of Open Access Journals (Sweden)

    Carolina Dantas Figueiredo

    2012-12-01

    Full Text Available Cinema constantly shows the struggle between the men and artificial intelligences. Fiction, and more specifically fiction films, lends itself to explore possibilities asking “what if?”. “What if”, in this case, is related to the eventual rebellion of artificial intelligences, theme explored in the movies Tron (1982 and Tron Legacy (2010 trat portray the conflict between programs and users. The present paper examines these films, observing particularly the possibility programs empowering. Finally, is briefly mentioned the concept of cyborg as a possibility of response to human concerns.

  12. Beneficial effect of daidzin in dry eye rat model through the suppression of inflammation and oxidative stress in the cornea

    Directory of Open Access Journals (Sweden)

    Fan Xiao

    2018-05-01

    Full Text Available Present investigation evaluates the effect of daidzin in dry eye rat model through the suppression of inflammation and oxidative stress in the cornea. Briefly, electron spine resonance was used for the estimation of radical scavenging activity of daidzin and COX Fluorescent Activity Assay Kit was used for the estimation of PGS activity. Dry eye rat model was developed by removing the lacrimal gland and effect of daidzin was evaluated in dry eye rat model by estimating the fluorescein score, tear volume and expressions of heme oxigenase (HO-1, TNF α, Interlukin 6 (IL-6, matrix metallopeptidase 9 (MMP-9 and PGS-2. Result of the present study suggested that daidzin possess tyrosyl radical scavenging activity and thereby decreases the oxidative stress. Activity of PGS significantly increases in dry eye which was inhibited by daidzin treatment due to competitive inhibition of PGS. It also recovers the tear volume in dry eye rat model in which lacrimal gland was removed. Thus corneal erosion was improved by daidzin in dry eye rat model. Thus present study concludes that treatment with daidzin protects the cornea in dry eye rat model by suppression inflammation and oxidative stress. Keywords: Daidzin, Dry eye, Radical scavenging activity, Inflammation

  13. Identification of cataract and post-cataract surgery optical images using artificial intelligence techniques.

    Science.gov (United States)

    Acharya, Rajendra Udyavara; Yu, Wenwei; Zhu, Kuanyi; Nayak, Jagadish; Lim, Teik-Cheng; Chan, Joey Yiptong

    2010-08-01

    Human eyes are most sophisticated organ, with perfect and interrelated subsystems such as retina, pupil, iris, cornea, lens and optic nerve. The eye disorder such as cataract is a major health problem in the old age. Cataract is formed by clouding of lens, which is painless and developed slowly over a long period. Cataract will slowly diminish the vision leading to the blindness. At an average age of 65, it is most common and one third of the people of this age in world have cataract in one or both the eyes. A system for detection of the cataract and to test for the efficacy of the post-cataract surgery using optical images is proposed using artificial intelligence techniques. Images processing and Fuzzy K-means clustering algorithm is applied on the raw optical images to detect the features specific to three classes to be classified. Then the backpropagation algorithm (BPA) was used for the classification. In this work, we have used 140 optical image belonging to the three classes. The ANN classifier showed an average rate of 93.3% in detecting normal, cataract and post cataract optical images. The system proposed exhibited 98% sensitivity and 100% specificity, which indicates that the results are clinically significant. This system can also be used to test the efficacy of the cataract operation by testing the post-cataract surgery optical images.

  14. Optical coherence elastography assesses tissue modifications in laser reshaping of cornea and cartilages

    Science.gov (United States)

    Zaitsev, V. Y.; Matveyev, A. L.; Matveev, L. A.; Gelikonov, G. V.; Omelchenko, A. I.; Shabanov, D. V.; Sovetsky, A. A.; Baum, O. I.; Vitkin, A.; Sobol, E. N.

    2018-02-01

    Non-surgical thermo-mechanical reshaping of avascular collagenous tissues (cartilages and cornea) using moderate heating by IR-laser irradiation is an emerging technology that can find important applications in visioncorrection problems and preparation of cartilaginous implants in otolaryngology. To estimate both transient interframe strains and cumulative resultant strains produced by the laser irradiation of the tissue we use and improved version of strain mapping developed in our previous work related to compressional phase-sensitive optical coherence tomography. To reveal microstructural changes in the tissue regions where irradiation-produced strains do not disappear after temperature equilibration, we apply compressional optical coherence elastography in order to visualize the resultant variations in the tissue stiffness. The so-found regions of the stiffness reduction are attributed to formation of microscopic pores, existence of which agree with independent data obtained using methods of high-resolution microscopy.

  15. Synaptic Plasticity and Nociception

    Institute of Scientific and Technical Information of China (English)

    ChenJianguo

    2004-01-01

    Synaptic plasticity is one of the fields that progresses rapidly and has a lot of success in neuroscience. The two major types of synaptie plasticity: long-term potentiation ( LTP and long-term depression (LTD are thought to be the cellular mochanisms of learning and memory. Recently, accumulating evidence suggests that, besides serving as a cellular model for learning and memory, the synaptic plasticity involves in other physiological or pathophysiological processes, such as the perception of pain and the regulation of cardiovascular system. This minireview will focus on the relationship between synaptic plasticity and nociception.

  16. Sustained Subconjunctival Delivery of Infliximab Protects the Cornea and Retina Following Alkali Burn to the Eye.

    Science.gov (United States)

    Zhou, Chengxin; Robert, Marie-Claude; Kapoulea, Vassiliki; Lei, Fengyang; Stagner, Anna M; Jakobiec, Frederick A; Dohlman, Claes H; Paschalis, Eleftherios I

    2017-01-01

    Tumor necrosis factor (TNF)-α is upregulated in eyes following corneal alkali injury and contributes to corneal and also retinal damage. Prompt TNF-α inhibition by systemic infliximab ameliorates retinal damage and improves corneal wound healing. However, systemic administration of TNF-α inhibitors carries risk of significant complications, whereas topical eye-drop delivery is hindered by poor ocular bioavailability and the need for patient adherence. This study investigates the efficacy of subconjunctival delivery of TNF-α antibodies using a polymer-based drug delivery system (DDS). The drug delivery system was prepared using porous polydimethylsiloxane/polyvinyl alcohol composite fabrication and loaded with 85 μg of infliximab. Six Dutch-belted pigmented rabbits received ocular alkali burn with NaOH. Immediately after the burn, subconjunctival implantation of anti-TNF-α DDS was performed in three rabbits while another three received sham DDS (without antibody). Rabbits were followed with photography for 3 months. After 3 months, the device was found to be well tolerated by the host and the eyes exhibited less corneal damage as compared to eyes implanted with a sham DDS without drug. The low dose treatment suppressed CD45 and TNF-α expression in the burned cornea and inhibited retinal ganglion cell apoptosis and optic nerve degeneration, as compared to the sham DDS treated eyes. Immunolocalization revealed drug penetration in the conjunctiva, cornea, iris, and choroid, with residual infliximab in the DDS 3 months after implantation. This reduced-risk biologic DDS improves corneal wound healing and provides retinal neuroprotection, and may be applicable not only to alkali burns but also to other inflammatory surgical procedures such as penetrating keratoplasty and keratoprosthesis implantation.

  17. Synthesis of biodegradable plastic from tapioca with N-Isopropylacrylamid and chitosan using glycerol as plasticizer

    Science.gov (United States)

    Syaubari; Safwani, S.; Riza, M.

    2018-04-01

    One of natural polymers that can be used as raw material in the manufacture of biodegradable plastic is tapioca and chitosan. The addition of other compounds such as glycerol as plasticizer is to improve the characteristics of the plastic that already produced. N- Isopropylacrylamid (NIPAm) is an organic compound that can be synthesized into a polymer or polymer grafting which also biodegradable too. This research aims tostudy the synthesis of biodegradable plastics from tapioca with the addition of chitosan, NIPAm, poly(NIPAm) and analyze the characteristics of biodegradable plastics that already produced. This research was done in three stages, there are (1) polymerization NIPAm, (2) the grafting of chitosan-poly NIPAm and (3) the synthesis of biodegradable plastics from starch mixture with variation of addition chitosan, NIPAm, poly(NIPAm), chitosan-graft-poly(NIPAm) and also variations of glycerol as plasticizer. The results of this research is a thin sheet of plastic which is will get analyzed for the characteristics of functional groups, mechanical, morphological and its biodegradability. FTIR spectra showed the grafting process with the new group formation of CO single-bond at 850 cm-1. Plastic with the addition of NIPAm and 1 ml glycerol has the highest tensile strength value about 31.1 MPa. Plastic with poly(NIPAm) and 4 ml glycerol produces the highest elongation value about 153.72%. Plastic with Chitosan-graft-poly(NIPAm) with 1 ml glycerol has the longest biodegradation because of the small mass-loss for six weeks which is about 6.6%.

  18. New perspectives in plastic biodegradation.

    Science.gov (United States)

    Sivan, Alex

    2011-06-01

    During the past 50 years new plastic materials, in various applications, have gradually replaced the traditional metal, wood, leather materials. Ironically, the most preferred property of plastics--durability--exerts also the major environmental threat. Recycling has practically failed to provide a safe solution for disposal of plastic waste (only 5% out of 1 trillion plastic bags, annually produced in the US alone, are being recycled). Since the most utilized plastic is polyethylene (PE; ca. 140 million tons/year), any reduction in the accumulation of PE waste alone would have a major impact on the overall reduction of the plastic waste in the environment. Since PE is considered to be practically inert, efforts were made to isolate unique microorganisms capable of utilizing synthetic polymers. Recent data showed that biodegradation of plastic waste with selected microbial strains became a viable solution. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. Avalanches and plastic flow in crystal plasticity: an overview

    Science.gov (United States)

    Papanikolaou, Stefanos; Cui, Yinan; Ghoniem, Nasr

    2018-01-01

    Crystal plasticity is mediated through dislocations, which form knotted configurations in a complex energy landscape. Once they disentangle and move, they may also be impeded by permanent obstacles with finite energy barriers or frustrating long-range interactions. The outcome of such complexity is the emergence of dislocation avalanches as the basic mechanism of plastic flow in solids at the nanoscale. While the deformation behavior of bulk materials appears smooth, a predictive model should clearly be based upon the character of these dislocation avalanches and their associated strain bursts. We provide here a comprehensive overview of experimental observations, theoretical models and computational approaches that have been developed to unravel the multiple aspects of dislocation avalanche physics and the phenomena leading to strain bursts in crystal plasticity.

  20. Melting the Plastic Ceiling: Overcoming Obstacles to Foster Leadership in Women Plastic Surgeons.

    Science.gov (United States)

    Silva, Amanda K; Preminger, Aviva; Slezak, Sheri; Phillips, Linda G; Johnson, Debra J

    2016-09-01

    The underrepresentation of women leaders in plastic surgery echoes a phenomenon throughout society. The importance of female leadership is presented, and barriers to gender equality in plastic surgery, both intrinsic and extrinsic, are discussed. Strategies for fostering women in leadership on an individual level and for the specialty of plastic surgery are presented.

  1. Some Limitations in the Use of Plastic and Dyed Plastic Dosimeters

    DEFF Research Database (Denmark)

    Miller, Arne; Bjergbakke, Erling; McLaughlin, W. L.

    1975-01-01

    Several practical plastic and dyed plastic dosimeters were examined under irradiation conditions similar to those used for radiation processing of materials. Cellulose triacetate, polymethyl methacrylate, polyvinyl chloride, dyed polymethyl methacrylate, dyed Cellophane and dyed Nylon were given...

  2. Expression of c-Fos and c-Jun in the cornea, lens, and retina after ultraviolet irradiation of the rat eye and effect of topical antisense oligodeoxynucleotides

    International Nuclear Information System (INIS)

    Gillardon, F.; Zimmermann, M.

    1995-01-01

    Aims - Immunohistochemical techniques were used to investigate c-Fos and c-Jun proto-oncogene expression in the cornea, lens, and retina after ultraviolet irradiation of the rat eye. Methods -Eyes of anaesthetised rats were exposed to 1.5 J/cm 2 of ultraviolet radiation (280-380 nm). Animals were perfused 1, 6, or 24 hours after irradiation and tissue sections were incubated with specific antiserum to c-Fos and c-Jun, respectively. Non-irradiated contralateral eyes displayed no c-Fos and c-Jun immunoreactivity. One and 6 hours after ultraviolet exposure numerous c-Fos and c-Jun immunopositive nuclei were observed mainly in the epithelial cell layers of the cornea and the lens epithelium. Scattered labelled nuclei were detectable in the retinal ganglion cell layer and the inner nuclear layer. Twenty four hours after irradiation c-Fos and c-Jun protein expression returned to near control levels. Histological signs of ultraviolet damage (for example, chromatin condensation, nuclear fragmentation) were first recognisable in the corneal epithelium 6 hours after irradiation and became more apparent at later times. The rapid and sustained activation of c-Fos and c-Jun expression in the eye after single ultraviolet exposure may represent the molecular mechanism underlying ultraviolet induced photodamage and initiation of cell death. Furthermore, topical application of a c-fos antisense oligode-oxynucleotide to the ultraviolet exposed rat eye inhibited the increase in c-Fos expression in the cornea, suggesting therapeutic activity of antisense drugs in corneal malignant and infectious diseases. (author)

  3. [Total artificial heart].

    Science.gov (United States)

    Antretter, H; Dumfarth, J; Höfer, D

    2015-09-01

    To date the CardioWest™ total artificial heart is the only clinically available implantable biventricular mechanical replacement for irreversible cardiac failure. This article presents the indications, contraindications, implantation procedere and postoperative treatment. In addition to a overview of the applications of the total artificial heart this article gives a brief presentation of the two patients treated in our department with the CardioWest™. The clinical course, postoperative rehabilitation, device-related complications and control mechanisms are presented. The total artificial heart is a reliable implant for treating critically ill patients with irreversible cardiogenic shock. A bridge to transplantation is feasible with excellent results.

  4. Artificial Intelligence in Astronomy

    Science.gov (United States)

    Devinney, E. J.; Prša, A.; Guinan, E. F.; Degeorge, M.

    2010-12-01

    From the perspective (and bias) as Eclipsing Binary researchers, we give a brief overview of the development of Artificial Intelligence (AI) applications, describe major application areas of AI in astronomy, and illustrate the power of an AI approach in an application developed under the EBAI (Eclipsing Binaries via Artificial Intelligence) project, which employs Artificial Neural Network technology for estimating light curve solution parameters of eclipsing binary systems.

  5. Model-Driven Analysis of Eyeblink Classical Conditioning Reveals the Underlying Structure of Cerebellar Plasticity and Neuronal Activity.

    Science.gov (United States)

    Antonietti, Alberto; Casellato, Claudia; D'Angelo, Egidio; Pedrocchi, Alessandra

    The cerebellum plays a critical role in sensorimotor control. However, how the specific circuits and plastic mechanisms of the cerebellum are engaged in closed-loop processing is still unclear. We developed an artificial sensorimotor control system embedding a detailed spiking cerebellar microcircuit with three bidirectional plasticity sites. This proved able to reproduce a cerebellar-driven associative paradigm, the eyeblink classical conditioning (EBCC), in which a precise time relationship between an unconditioned stimulus (US) and a conditioned stimulus (CS) is established. We challenged the spiking model to fit an experimental data set from human subjects. Two subsequent sessions of EBCC acquisition and extinction were recorded and transcranial magnetic stimulation (TMS) was applied on the cerebellum to alter circuit function and plasticity. Evolutionary algorithms were used to find the near-optimal model parameters to reproduce the behaviors of subjects in the different sessions of the protocol. The main finding is that the optimized cerebellar model was able to learn to anticipate (predict) conditioned responses with accurate timing and success rate, demonstrating fast acquisition, memory stabilization, rapid extinction, and faster reacquisition as in EBCC in humans. The firing of Purkinje cells (PCs) and deep cerebellar nuclei (DCN) changed during learning under the control of synaptic plasticity, which evolved at different rates, with a faster acquisition in the cerebellar cortex than in DCN synapses. Eventually, a reduced PC activity released DCN discharge just after the CS, precisely anticipating the US and causing the eyeblink. Moreover, a specific alteration in cortical plasticity explained the EBCC changes induced by cerebellar TMS in humans. In this paper, for the first time, it is shown how closed-loop simulations, using detailed cerebellar microcircuit models, can be successfully used to fit real experimental data sets. Thus, the changes of the

  6. Plastic Fishes

    CERN Multimedia

    Trettnak, Wolfgang

    2015-01-01

    In terms of weight, the plastic pollution in the world’s oceans is estimated to be around 300,000 tonnes. This plastic comes from both land-based and ocean-based sources. A lecture at CERN by chemist Wolfgang Trettnak addressed this issue and highlighted the role of art in raising people’s awareness. The slideshow below gives you a taste of the artworks by Wolfgang Trettnak and Margarita Cimadevila.

  7. Plasticity resembling spike-timing dependent synaptic plasticity: the evidence in human cortex

    Directory of Open Access Journals (Sweden)

    Florian Müller-Dahlhaus

    2010-07-01

    Full Text Available Spike-timing dependent plasticity (STDP has been studied extensively in a variety of animal models during the past decade but whether it can be studied at the systems level of the human cortex has been a matter of debate. Only recently newly developed non-invasive brain stimulation techniques such as transcranial magnetic stimulation (TMS have made it possible to induce and assess timing dependent plasticity in conscious human subjects. This review will present a critical synopsis of these experiments, which suggest that several of the principal characteristics and molecular mechanisms of TMS-induced plasticity correspond to those of STDP as studied at a cellular level. TMS combined with a second phasic stimulation modality can induce bidirectional long-lasting changes in the excitability of the stimulated cortex, whose polarity depends on the order of the associated stimulus-evoked events within a critical time window of tens of milliseconds. Pharmacological evidence suggests an NMDA receptor mediated form of synaptic plasticity. Studies in human motor cortex demonstrated that motor learning significantly modulates TMS-induced timing dependent plasticity, and, conversely, may be modulated bidirectionally by prior TMS-induced plasticity, providing circumstantial evidence that long-term potentiation-like mechanisms may be involved in motor learning. In summary, convergent evidence is being accumulated for the contention that it is now possible to induce STDP-like changes in the intact human central nervous system by means of TMS to study and interfere with synaptic plasticity in neural circuits in the context of behaviour such as learning and memory.

  8. [Preparation of nano-nacre artificial bone].

    Science.gov (United States)

    Chen, Jian-ting; Tang, Yong-zhi; Zhang, Jian-gang; Wang, Jian-jun; Xiao, Ying

    2008-12-01

    To assess the improvements in the properties of nano-nacre artificial bone prepared on the basis of nacre/polylactide acid composite artificial bone and its potential for clinical use. The compound of nano-scale nacre powder and poly-D, L-lactide acid (PDLLA) was used to prepare the cylindrical hollow artificial bone, whose properties including raw material powder scale, pore size, porosity and biomechanical characteristics were compared with another artificial bone made of micron-scale nacre powder and PDLLA. Scanning electron microscope showed that the average particle size of the nano-nacre powder was 50.4-/+12.4 nm, and the average pore size of the artificial bone prepared using nano-nacre powder was 215.7-/+77.5 microm, as compared with the particle size of the micron-scale nacre powder of 5.0-/+3.0 microm and the pore size of the resultant artificial bone of 205.1-/+72.0 microm. The porosities of nano-nacre artificial bone and the micron-nacre artificial bone were (65.4-/+2.9)% and (53.4-/+2.2)%, respectively, and the two artificial bones had comparable compressive strength and Young's modulus, but the flexural strength of the nano-nacre artificial bone was lower than that of the micro-nacre artificial bone. The nano-nacre artificial bone allows better biodegradability and possesses appropriate pore size, porosity and biomechanical properties for use as a promising material in bone tissue engineering.

  9. Plastic and Non-plastic Debris Ingestion in Three Gull Species Feeding in an Urban Landfill Environment.

    Science.gov (United States)

    Seif, S; Provencher, J F; Avery-Gomm, S; Daoust, P-Y; Mallory, M L; Smith, P A

    2018-04-01

    Plastic debris is recognized as a widespread, common and problematic environmental pollutant. An important consequence of this pollution is the ingestion of plastic debris by wildlife. Assessing the degree to which different species ingest plastics, and the potential effects of these plastics on their health are important research needs for understanding the impacts of plastic pollution. We examined debris (plastic and other types) ingestion in three sympatric overwintering gull species (Herring gulls Larus smithsonianus, Great Black-backed Gulls Larus marinus, and Iceland Gulls Larus glaucoides) to understand how debris ingestion differs among species, age classes and sexes in gulls. We also assessed how plastic burdens were associated with body condition to investigate how gulls may be affected by debris ingestion. There were no differences among the species, age classes or sexes in the incidence of debris ingestion (plastic or otherwise), the mass or number of debris pieces ingested. We found no correlation between ingested plastics burdens and individual condition. Gulls ingested plastic debris, but also showed high levels of other debris types as well, including metal, glass and building materials, including a metal piece of debris found within an abscess in the stomach. Thus, when the health effects of debris ingestion on gulls, and other species that ingest debris, is of interest, either from a physical or chemical perspective, it may be necessary to consider all debris types and not just plastic burdens as is often currently done for seabirds.

  10. Education on the Business of Plastic Surgery During Training: A Survey of Plastic Surgery Residents.

    Science.gov (United States)

    Ovadia, Steven A; Gishen, Kriya; Desai, Urmen; Garcia, Alejandro M; Thaller, Seth R

    2018-06-01

    Entrepreneurial skills are important for physicians, especially plastic surgeons. Nevertheless, these skills are not typically emphasized during residency training. Evaluate the extent of business training at plastic surgery residency programs as well as means of enhancing business training. A 6-question online survey was sent to plastic surgery program directors for distribution to plastic surgery residents. Responses from residents at the PGY2 level and above were included for analysis. Tables were prepared to present survey results. Hundred and sixty-six residents including 147 PGY2 and above residents responded to our survey. Only 43.5% reported inclusion of business training in their plastic surgery residency. A majority of residents reported they do not expect on graduation to be prepared for the business aspects of plastic surgery. Additionally, a majority of residents feel establishment of a formal lecture series on the business of plastic surgery would be beneficial. Results from our survey indicate limited training at plastic surgery programs in necessary business skills. Plastic surgery residency programs should consider incorporating or enhancing elements of business training in their curriculum. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  11. The effects of plastic waves on the numerical convergence of the viscous-plastic and elastic-viscous-plastic sea-ice models

    Science.gov (United States)

    Williams, James; Tremblay, L. Bruno; Lemieux, Jean-François

    2017-07-01

    The plastic wave speed is derived from the linearized 1-D version of the widely used viscous-plastic (VP) and elastic-viscous-plastic (EVP) sea-ice models. Courant-Friedrichs-Lewy (CFL) conditions are derived using the propagation speed of the wave. 1-D numerical experiments of the VP, EVP and EVP* models successfully recreate a reference solution when the CFL conditions are satisfied, in agreement with the theory presented. The IMplicit-EXplicit (IMEX) method is shown to effectively alleviate the plastic wave CFL constraint on the timestep in the implicitly solved VP model in both 1-D and 2-D. In 2-D, the EVP and EVP* models show first order error in the simulated velocity field when the plastic wave is not resolved. EVP simulations are performed with various advective timestep, number of subcycles, and elastic-wave damping timescales. It is found that increasing the number of subcycles beyond that needed to resolve the elastic wave does not improve the quality of the solution. It is found that reducing the elastic wave damping timescale reduces the spatial extent of first order errors cause by the unresolved plastic wave. Reducing the advective timestep so that the plastic wave is resolved also reduces the velocity error in terms of magnitude and spatial extent. However, the parameter set required for convergence to within the error bars of satellite (RGPS) deformation fields is impractical for use in climate model simulations. The behavior of the EVP* method is analogous to that of the EVP method except that it is not possible to reduce the damping timescale with α = β.

  12. Coliquefaction of coal, tar sand bitumen and plastic (interaction among coal, bitumen and plastic); Sekitan/tar sand bitumen/plastic no kyoekika ni okeru kyozon busshitsu no eikyo

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, H.; Okuyama, Y.; Matsubara, K. [NKK Corp., Tokyo (Japan); Kamo, T.; Sato, Y. [National Institute for Resources and Environment, Tsukuba (Japan)

    1996-10-28

    For the improvement of economy, coliquefaction of coal, tar sand bitumen and plastic was performed under low hydrogen pressure, to investigate the influence of interaction among these on the liquefaction characteristics. For comparison, coliquefaction was also performed under the hydrogen pressure same as the NEDOL process. In addition, for clarifying its reaction mechanism, coliquefaction of dibenzyl and plastic was performed as a model experiment, to illustrate the distribution of products and composition of oil, and to discuss the interaction between dibenzyl and various plastics, and between various plastics. Under direct coal liquefaction conditions, coprocessing of Tanito Harum coal, Athabasca tar sand and plastic was carried out under low hydrogen pressure with an autoclave. The observed value of oil yield was higher than the calculated value based on the values from separate liquefaction of coal and plastic, which suggested the interaction between coal and the mixed plastic. The results of coliquefaction of coal, tar sand bitumen and plastic could be explained from the obtained oil yield and its composition by the coliquefaction of dibenzyl and plastic. 2 refs., 3 tabs.

  13. Artificial Intelligence Study (AIS).

    Science.gov (United States)

    1987-02-01

    ARTIFICIAL INTELLIGNECE HARDWARE ....... 2-50 AI Architecture ................................... 2-49 AI Hardware ....................................... 2...ftf1 829 ARTIFICIAL INTELLIGENCE STUDY (RIS)(U) MAY CONCEPTS 1/3 A~NLYSIS AGENCY BETHESA RD R B NOJESKI FED 6? CM-RP-97-1 NCASIFIED /01/6 M |K 1.0...p/ - - ., e -- CAA- RP- 87-1 SAOFŔ)11 I ARTIFICIAL INTELLIGENCE STUDY (AIS) tNo DTICFEBRUARY 1987 LECT 00 I PREPARED BY RESEARCH AND ANALYSIS

  14. A review of plastic waste biodegradation.

    Science.gov (United States)

    Zheng, Ying; Yanful, Ernest K; Bassi, Amarjeet S

    2005-01-01

    With more and more plastics being employed in human lives and increasing pressure being placed on capacities available for plastic waste disposal, the need for biodegradable plastics and biodegradation of plastic wastes has assumed increasing importance in the last few years. This review looks at the technological advancement made in the development of more easily biodegradable plastics and the biodegradation of conventional plastics by microorganisms. Additives, such as pro-oxidants and starch, are applied in synthetic materials to modify and make plastics biodegradable. Recent research has shown that thermoplastics derived from polyolefins, traditionally considered resistant to biodegradation in ambient environment, are biodegraded following photo-degradation and chemical degradation. Thermoset plastics, such as aliphatic polyester and polyester polyurethane, are easily attacked by microorganisms directly because of the potential hydrolytic cleavage of ester or urethane bonds in their structures. Some microorganisms have been isolated to utilize polyurethane as a sole source of carbon and nitrogen source. Aliphatic-aromatic copolyesters have active commercial applications because of their good mechanical properties and biodegradability. Reviewing published and ongoing studies on plastic biodegradation, this paper attempts to make conclusions on potentially viable methods to reduce impacts of plastic waste on the environment.

  15. Recycling of plastics

    Energy Technology Data Exchange (ETDEWEB)

    Kaminsky, W; Menzel, J; Sinn, H

    1976-01-01

    Considering the shortage of raw materials and environmental pollution, the recycling of plastic waste is a very important topic. Pilot plants for research in Funabashi Japan, Franklin (Ohio) U.S.A., and the R 80-process of Krauss Maffei, W. Germany, have demonstrated the possibility of reclaiming plastics from refuse. Old tires and waste from the plastic producing and manufacturing industries are readily available. The pyrolysis of plastic yields gaseous and liquid products, and the exploitation of this cracking reaction has been demonstrated by pilot plants in Japan and Great Britain. Further laboratory scale experiments are taking place in W. Germany. In continuous fluidized beds and in molten salts, polyethylene, polypropylene, polyvinylchloride, polystyrene and rubber are pyrolysed and better than 98 percent conversion is obtained. Up to 40 percent of the feed can be obtained as aromatic compounds, and a pilot plant is under construction. As a first step PVC-containing material can be almost quantitatively dehydrochlorinated.

  16. Stem cell plasticity.

    Science.gov (United States)

    Lakshmipathy, Uma; Verfaillie, Catherine

    2005-01-01

    The central dogma in stem cell biology has been that cells isolated from a particular tissue can renew and differentiate into lineages of the tissue it resides in. Several studies have challenged this idea by demonstrating that tissue specific cell have considerable plasticity and can cross-lineage restriction boundary and give rise to cell types of other lineages. However, the lack of a clear definition for plasticity has led to confusion with several reports failing to demonstrate that a single cell can indeed differentiate into multiple lineages at significant levels. Further, differences between results obtained in different labs has cast doubt on some results and several studies still await independent confirmation. In this review, we critically evaluate studies that report stem cell plasticity using three rigid criteria to define stem cell plasticity; differentiation of a single cell into multiple cell lineages, functionality of differentiated cells in vitro and in vivo, robust and persistent engraft of transplanted cells.

  17. Cross-Linked Amylose Bio-Plastic: A Transgenic-Based Compostable Plastic Alternative

    Directory of Open Access Journals (Sweden)

    Domenico Sagnelli

    2017-09-01

    Full Text Available Bio-plastics and bio-materials are composed of natural or biomass derived polymers, offering solutions to solve immediate environmental issues. Polysaccharide-based bio-plastics represent important alternatives to conventional plastic because of their intrinsic biodegradable nature. Amylose-only (AO, an engineered barley starch with 99% amylose, was tested to produce cross-linked all-natural bioplastic using normal barley starch as a control. Glycerol was used as plasticizer and citrate cross-linking was used to improve the mechanical properties of cross-linked AO starch extrudates. Extrusion converted the control starch from A-type to Vh- and B-type crystals, showing a complete melting of the starch crystals in the raw starch granules. The cross-linked AO and control starch specimens displayed an additional wide-angle diffraction reflection. Phospholipids complexed with Vh-type single helices constituted an integrated part of the AO starch specimens. Gas permeability tests of selected starch-based prototypes demonstrated properties comparable to that of commercial Mater-Bi© plastic. The cross-linked AO prototypes had composting characteristics not different from the control, indicating that the modified starch behaves the same as normal starch. The data shows the feasibility of producing all-natural bioplastic using designer starch as raw material.

  18. Cross-Linked Amylose Bio-Plastic: A Transgenic-Based Compostable Plastic Alternative

    Science.gov (United States)

    Sagnelli, Domenico; Kemmer, Gerdi Christine; Holse, Mette; Hebelstrup, Kim H.; Bao, Jinsong; Stelte, Wolfgang; Bjerre, Anne-Belinda; Blennow, Andreas

    2017-01-01

    Bio-plastics and bio-materials are composed of natural or biomass derived polymers, offering solutions to solve immediate environmental issues. Polysaccharide-based bio-plastics represent important alternatives to conventional plastic because of their intrinsic biodegradable nature. Amylose-only (AO), an engineered barley starch with 99% amylose, was tested to produce cross-linked all-natural bioplastic using normal barley starch as a control. Glycerol was used as plasticizer and citrate cross-linking was used to improve the mechanical properties of cross-linked AO starch extrudates. Extrusion converted the control starch from A-type to Vh- and B-type crystals, showing a complete melting of the starch crystals in the raw starch granules. The cross-linked AO and control starch specimens displayed an additional wide-angle diffraction reflection. Phospholipids complexed with Vh-type single helices constituted an integrated part of the AO starch specimens. Gas permeability tests of selected starch-based prototypes demonstrated properties comparable to that of commercial Mater-Bi© plastic. The cross-linked AO prototypes had composting characteristics not different from the control, indicating that the modified starch behaves the same as normal starch. The data shows the feasibility of producing all-natural bioplastic using designer starch as raw material. PMID:28973963

  19. Cross-Linked Amylose Bio-Plastic: A Transgenic-Based Compostable Plastic Alternative.

    Science.gov (United States)

    Sagnelli, Domenico; Hooshmand, Kourosh; Kemmer, Gerdi Christine; Kirkensgaard, Jacob J K; Mortensen, Kell; Giosafatto, Concetta Valeria L; Holse, Mette; Hebelstrup, Kim H; Bao, Jinsong; Stelte, Wolfgang; Bjerre, Anne-Belinda; Blennow, Andreas

    2017-09-30

    Bio-plastics and bio-materials are composed of natural or biomass derived polymers, offering solutions to solve immediate environmental issues. Polysaccharide-based bio-plastics represent important alternatives to conventional plastic because of their intrinsic biodegradable nature. Amylose-only (AO), an engineered barley starch with 99% amylose, was tested to produce cross-linked all-natural bioplastic using normal barley starch as a control. Glycerol was used as plasticizer and citrate cross-linking was used to improve the mechanical properties of cross-linked AO starch extrudates. Extrusion converted the control starch from A-type to Vh- and B-type crystals, showing a complete melting of the starch crystals in the raw starch granules. The cross-linked AO and control starch specimens displayed an additional wide-angle diffraction reflection. Phospholipids complexed with Vh-type single helices constituted an integrated part of the AO starch specimens. Gas permeability tests of selected starch-based prototypes demonstrated properties comparable to that of commercial Mater-Bi © plastic. The cross-linked AO prototypes had composting characteristics not different from the control, indicating that the modified starch behaves the same as normal starch. The data shows the feasibility of producing all-natural bioplastic using designer starch as raw material.

  20. Solar Radiation Measurement Using Raspberry Pi and Its Modelling Using Artificial Neural Networks

    Directory of Open Access Journals (Sweden)

    Priya Selvanathan Shanmuga

    2016-01-01

    Full Text Available The advent of solar energy as the best alternative to traditional energy sources has led to an extensive study on the measurement and prediction of solar radiation. Devices such as pyranometer, pyrrheliometer, global UV radiometer are used for the measurement of solar radiation. The solar radiation measuring instruments available at Innovation Center, MIT Manipal were integrated with a Raspberry Pi to allow remote access to the data through the university Local Area Network. The connections of the data loggers and the Raspberry Pi were enclosed in a plastic box to prevent damage from the rainfall and humidity in Manipal. The solar radiation data was used to validate an Artificial Neural Network model which was developed using various meterological data from 2011-2015.

  1. Irradiation of the rabbit cornea with UVB rays stimulates the expression of nitric oxide synthases-generated nitric oxide and the formation of cytotoxic nitrogen-related oxidants

    Czech Academy of Sciences Publication Activity Database

    Čejková, Jitka; Ardan, Taras; Andonova, Janetta; Zídek, Zdeněk

    2005-01-01

    Roč. 20, - (2005), s. 467-473 ISSN 0213-3911 R&D Projects: GA ČR GA304/03/0419 Institutional research plan: CEZ:AV0Z5008914 Keywords : UVB rays * Reactive nitrogen species * Cornea Subject RIV: FF - HEENT, Dentistry Impact factor: 2.023, year: 2005

  2. Quo Vadis, Artificial Intelligence?

    OpenAIRE

    Berrar, Daniel; Sato, Naoyuki; Schuster, Alfons

    2010-01-01

    Since its conception in the mid 1950s, artificial intelligence with its great ambition to understand and emulate intelligence in natural and artificial environments alike is now a truly multidisciplinary field that reaches out and is inspired by a great diversity of other fields. Rapid advances in research and technology in various fields have created environments into which artificial intelligence could embed itself naturally and comfortably. Neuroscience with its desire to understand nervou...

  3. Inteligencia artificial en vehiculo

    OpenAIRE

    Amador Díaz, Pedro

    2012-01-01

    Desarrollo de un robot seguidor de líneas, en el que se implementan diversas soluciones de las áreas de sistemas embebidos e inteligencia artificial. Desenvolupament d'un robot seguidor de línies, en el qual s'implementen diverses solucions de les àrees de sistemes encastats i intel·ligència artificial. Follower robot development of lines, in which various solutions are implemented in the areas of artificial intelligence embedded systems.

  4. Tear dysfunction and the cornea: LXVIII Edward Jackson Memorial Lecture.

    Science.gov (United States)

    Pflugfelder, Stephen C

    2011-12-01

    To describe the cause and consequence of tear dysfunction-related corneal disease. Perspective on effects of tear dysfunction on the cornea. Evidence is presented on the effects of tear dysfunction on corneal morphology, function, and health, as well as efficacy of therapies for tear dysfunction-related corneal disease. Tear dysfunction is a prevalent eye disease and the most frequent cause for superficial corneal epithelial disease that results in corneal barrier disruption, an irregular optical surface, light scattering, optical aberrations, and exposure and sensitization of pain-sensing nerve endings (nociceptors). Tear dysfunction-related corneal disease causes irritation and visual symptoms such as photophobia and blurred and fluctuating vision that may decrease quality of life. Dysfunction of 1 or more components of the lacrimal functional unit results in changes in tear composition, including elevated osmolarity and increased concentrations of matrix metalloproteinases, inflammatory cytokines, and chemokines. These tear compositional changes promote disruption of tight junctions, alter differentiation, and accelerate death of corneal epithelial cells. Corneal epithelial disease resulting from tear dysfunction causes eye irritation and decreases visual function. Clinical and basic research has improved understanding of the pathogenesis of tear dysfunction-related corneal epithelial disease, as well as treatment outcomes. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Plastics and beaches: A degrading relationship

    International Nuclear Information System (INIS)

    Corcoran, Patricia L.; Biesinger, Mark C.; Grifi, Meriem

    2009-01-01

    Plastic debris in Earth's oceans presents a serious environmental issue because breakdown by chemical weathering and mechanical erosion is minimal at sea. Following deposition on beaches, plastic materials are exposed to UV radiation and physical processes controlled by wind, current, wave and tide action. Plastic particles from Kauai's beaches were sampled to determine relationships between composition, surface textures, and plastics degradation. SEM images indicated that beach plastics feature both mechanically eroded and chemically weathered surface textures. Granular oxidation textures were concentrated along mechanically weakened fractures and along the margins of the more rounded plastic particles. Particles with oxidation textures also produced the most intense peaks in the lower wavenumber region of FTIR spectra. The textural results suggest that plastic debris is particularly conducive to both chemical and mechanical breakdown in beach environments, which cannot be said for plastics in other natural settings on Earth

  6. Art and Plastic Surgery.

    Science.gov (United States)

    Fernandes, Julio Wilson; Metka, Susanne

    2016-04-01

    The roots of science and art of plastic surgery are very antique. Anatomy, drawing, painting, and sculpting have been very important to the surgery and medicine development over the centuries. Artistic skills besides shape, volume, and lines perception can be a practical aid to the plastic surgeons' daily work. An overview about the interactions between art and plastic surgery is presented, with a few applications to rhinoplasty, cleft lip, and other reconstructive plastic surgeries. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.

  7. Criminal Aspects of Artificial Abortion

    OpenAIRE

    Hartmanová, Leona

    2016-01-01

    Criminal Aspects of Artificial Abortion This diploma thesis deals with the issue of artificial abortion, especially its criminal aspects. Legal aspects are not the most important aspects of artificial abortion. Social, ethical or ideological aspects are of the same importance but this diploma thesis cannot analyse all of them. The main issue with artificial abortion is whether it is possible to force a pregnant woman to carry a child and give birth to a child when she cannot or does not want ...

  8. Plastics recycling: challenges and opportunities.

    Science.gov (United States)

    Hopewell, Jefferson; Dvorak, Robert; Kosior, Edward

    2009-07-27

    Plastics are inexpensive, lightweight and durable materials, which can readily be moulded into a variety of products that find use in a wide range of applications. As a consequence, the production of plastics has increased markedly over the last 60 years. However, current levels of their usage and disposal generate several environmental problems. Around 4 per cent of world oil and gas production, a non-renewable resource, is used as feedstock for plastics and a further 3-4% is expended to provide energy for their manufacture. A major portion of plastic produced each year is used to make disposable items of packaging or other short-lived products that are discarded within a year of manufacture. These two observations alone indicate that our current use of plastics is not sustainable. In addition, because of the durability of the polymers involved, substantial quantities of discarded end-of-life plastics are accumulating as debris in landfills and in natural habitats worldwide. Recycling is one of the most important actions currently available to reduce these impacts and represents one of the most dynamic areas in the plastics industry today. Recycling provides opportunities to reduce oil usage, carbon dioxide emissions and the quantities of waste requiring disposal. Here, we briefly set recycling into context against other waste-reduction strategies, namely reduction in material use through downgauging or product reuse, the use of alternative biodegradable materials and energy recovery as fuel. While plastics have been recycled since the 1970s, the quantities that are recycled vary geographically, according to plastic type and application. Recycling of packaging materials has seen rapid expansion over the last decades in a number of countries. Advances in technologies and systems for the collection, sorting and reprocessing of recyclable plastics are creating new opportunities for recycling, and with the combined actions of the public, industry and governments it

  9. Plastics recycling: challenges and opportunities

    Science.gov (United States)

    Hopewell, Jefferson; Dvorak, Robert; Kosior, Edward

    2009-01-01

    Plastics are inexpensive, lightweight and durable materials, which can readily be moulded into a variety of products that find use in a wide range of applications. As a consequence, the production of plastics has increased markedly over the last 60 years. However, current levels of their usage and disposal generate several environmental problems. Around 4 per cent of world oil and gas production, a non-renewable resource, is used as feedstock for plastics and a further 3–4% is expended to provide energy for their manufacture. A major portion of plastic produced each year is used to make disposable items of packaging or other short-lived products that are discarded within a year of manufacture. These two observations alone indicate that our current use of plastics is not sustainable. In addition, because of the durability of the polymers involved, substantial quantities of discarded end-of-life plastics are accumulating as debris in landfills and in natural habitats worldwide. Recycling is one of the most important actions currently available to reduce these impacts and represents one of the most dynamic areas in the plastics industry today. Recycling provides opportunities to reduce oil usage, carbon dioxide emissions and the quantities of waste requiring disposal. Here, we briefly set recycling into context against other waste-reduction strategies, namely reduction in material use through downgauging or product reuse, the use of alternative biodegradable materials and energy recovery as fuel. While plastics have been recycled since the 1970s, the quantities that are recycled vary geographically, according to plastic type and application. Recycling of packaging materials has seen rapid expansion over the last decades in a number of countries. Advances in technologies and systems for the collection, sorting and reprocessing of recyclable plastics are creating new opportunities for recycling, and with the combined actions of the public, industry and governments it

  10. Plastic pollutants in water environment

    OpenAIRE

    Mrowiec Bożena

    2017-01-01

    Nowadays, wide applications of plastics result in plastic waste being present in the water environment in a wide variety of sizes. Plastic wastes are in water mainly as microplastics (the size range of 1 nm to < 5 mm). Microplastics have been recognized as an emerging threat, as well as ecotoxicological and ecological risk for water ecosystems. In this review are presented some of the physicochemical properties of plastic materials that determine their toxic effect on the aquatic environment....

  11. DEVELOPMENT OF PLASTIC SURGERY.

    Science.gov (United States)

    Pećanac, Marija Đ

    2015-01-01

    Plastic surgery is a medical specialty dealing with corrections of defects, improvements in appearance and restoration of lost function. Ancient times. The first recorded account of reconstructive plastic surgery was found in ancient Indian Sanskrit texts, which described reconstructive surgeries of the nose and ears. In ancient Greece and Rome, many medicine men performed simple plastic cosmetic surgeries to repair damaged parts of the body caused by war mutilation, punishment or humiliation. In the Middle Ages, the development of all medical braches, including plastic surgery was hindered. New age. The interest in surgical reconstruction of mutilated body parts was renewed in the XVIII century by a great number of enthusiastic and charismatic surgeons, who mastered surgical disciplines and became true artists that created new forms. Modern era. In the XX century, plastic surgery developed as a modern branch in medicine including many types of reconstructive surgery, hand, head and neck surgery, microsurgery and replantation, treatment of burns and their sequelae, and esthetic surgery. Contemporary and future plastic surgery will continue to evolve and improve with regenerative medicine and tissue engineering resulting in a lot of benefits to be gained by patients in reconstruction after body trauma, oncology amputation, and for congenital disfigurement and dysfunction.

  12. A work criterion for plastic collapse

    International Nuclear Information System (INIS)

    Muscat, Martin; Mackenzie, Donald; Hamilton, Robert

    2003-01-01

    A new criterion for evaluating limit and plastic loads in pressure vessel design by analysis is presented. The proposed criterion is based on the plastic work dissipated in the structure as loading progresses and may be used for structures subject to a single load or a combination of multiple loads. Example analyses show that limit and plastic loads given by the plastic work criterion are robust and consistent. The limit and plastic loads are determined purely by the inelastic response of the structure and are not influenced by the initial elastic response: a problem with some established plastic criteria

  13. A Coupled Plastic Damage Model for Concrete considering the Effect of Damage on Plastic Flow

    OpenAIRE

    Zhou, Feng; Cheng, Guangxu

    2015-01-01

    A coupled plastic damage model with two damage scalars is proposed to describe the nonlinear features of concrete. The constitutive formulations are developed by assuming that damage can be represented effectively in the material compliance tensor. Damage evolution law and plastic damage coupling are described using the framework of irreversible thermodynamics. The plasticity part is developed without using the effective stress concept. A plastic yield function based on the true stress is ado...

  14. ESTUDO HISTOPATÓLOGICO NAS CÓRNEAS DOS CÃES TRATADOS COM 2-1 FOSFATO DISSÓDICO DE BETAMETASONA E FOSFATO DISSÓDICO/ACETATO DE DEXAMETASONA, QUE RECEBERAM TRASPLANTES COM CÓRNEAS DE SUÍNOS HISTOPHATOLOGICAL STUDY IN CORNEAS OF DOGS, TREATED WITH 2-1 DISSODIC FOSPHATE OF BETAMETHASONE AND DISSODIC FOSPHATED/ACETATE OF DEXAMETHASONE, THAT HAD RECEIVED IMPLANTATION OF SWINE CORNEAS

    Directory of Open Access Journals (Sweden)

    Luiz Antônio Franco da Silva

    2007-09-01

    Full Text Available

    Foram utilizados 10 cães, sem raça definida, com peso médio de 10kg, examinados e considerados sadios. Cada cão, a seu tempo, teve implantada no olho esquerdo córnea de suíno, conservada em câmara úmida pelo período máximo de seis horas. Cada animal antes da cirurgia recebeu 4 mg de fosfato dissódico/acetato de dexametasona, por via intramuscular, e uma gota de fosfato dissódico de betametasona/sulfato de gentamicina colírio. Conservou-se a medicação ocular 4 vezes/dia e a intramuscular semanalmente, até o sacrifício do cão. Cada qual foi sacrificado por processo indolor (thiopental sódico + cloreto de succinilcolina e teve o olho que recebeu implante com córnea de suíno enucleado. Foi injetado formol 10% na câmara do vítreo e a córnea foi removida com aba escleral, tratada e corada com hematoxilina-eosina. Foram analisadas as seguintes áreas: enxerto, áreas adjacentes receptoras e observadas as várias alterações.

    PALAVRAS-CHAVE: Histopatologia; corticosteróides; xenotransplantes; córnea; canino; suíno.

    Ten dogs, with no definitive breed, average weight of 10 kg, were in this research. After being examined and considered healthy they received numbers, from 11 to 20 in their collars. Each dog received implantation, in the left eye, of swine cornea, obtained at Casa de Banha Caçula, a slaughterhouse, and maintained in wet chamber for six hours at most. Before surgery, each animal received 4 mg of dissodic phosphate/acetate dexamethasone IM and, once a week one drop of dissodic phosphate betamethasone and gentamicin sulphate, four times a day, until the 28th day. when the animals were sacrificed through painless process (Thiopental sodic

  15. Plastic solid waste utilization technologies: A Review

    Science.gov (United States)

    Awasthi, Arun Kumar; Shivashankar, Murugesh; Majumder, Suman

    2017-11-01

    Plastics are used in more number of applications in worldwide and it becomes essential part of our daily life. In Indian cities and villages people use the plastics in buying vegetable as a carry bag, drinking water bottle, use of plastic furniture in home, plastics objects uses in kitchen, plastic drums in packing and storage of the different chemicals for industrial use, use plastic utensils in home and many more uses. After usage of plastics it will become part of waste garbage and create pollution due to presence of toxic chemicals and it will be spread diseases and give birth to uncontrolled issues in social society. In current scenario consumption of plastic waste increasing day by day and it is very difficult to manage the plastic waste. There are limited methodologies available for reutilization of plastic waste again. Such examples are recycling, landfill, incineration, gasification and hydrogenation. In this paper we will review the existing methodologies of utilization of plastic waste in current scenario

  16. Use of artificial neural networks in drug and explosive detection through tomographic images with thermal neutrons

    International Nuclear Information System (INIS)

    Ferreira, Francisco J.O.; Crispim, Verginia R.; Silva, Ademir X.

    2009-01-01

    The artificial neural network technique was used to identify drugs and plastic explosives, from a tomography composed by a set of six neutrongraphic projections obtained in real time. Bidimensional tomographic images of samples of drugs, explosives and other materials, when digitally processed, yield the characteristic spectra of each type of material. The information contained in those spectra was then used for ANN training, the best images being obtained when the multilayer perceptron model, the back-propagation training algorithm and the Cross-validation interruption criterion were used. ANN showed to be useful in forecasting presence of drugs and explosives hitting a rate of success above 97 %. (author)

  17. Plastic Pollution from Ships

    OpenAIRE

    Čulin, Jelena; Bielić, Toni

    2016-01-01

    The environmental impact of shipping on marine environment includes discharge of garbage. Plastic litter is of particular concern due to abundance, resistance to degradation and detrimental effect on marine biota. According to recently published studies, a further research is required to assess human health risk. Monitoring data indicate that despite banning plastic disposal at sea, shipping is still a source of plastic pollution. Some of the measures to combat the problem are discussed.

  18. Practical solution of plastic deformation problems in elastic-plastic range

    Science.gov (United States)

    Mendelson, A; Manson, S

    1957-01-01

    A practical method for solving plastic deformation problems in the elastic-plastic range is presented. The method is one of successive approximations and is illustrated by four examples which include a flat plate with temperature distribution across the width, a thin shell with axial temperature distribution, a solid cylinder with radial temperature distribution, and a rotating disk with radial temperature distribution.

  19. Synergistic Effect of Artificial Tears Containing Epigallocatechin Gallate and Hyaluronic Acid for the Treatment of Rabbits with Dry Eye Syndrome.

    Science.gov (United States)

    Tseng, Ching-Li; Hung, Ya-Jung; Chen, Zhi-Yu; Fang, Hsu-Wei; Chen, Ko-Hua

    2016-01-01

    Dry eye syndrome (DES) is a common eye disease. Artificial tears (AT) are used to treat DES, but they are not effective. In this study, we assessed the anti-inflammatory effect of AT containing epigallocatechin gallate (EGCG) and hyaluronic acid (HA) on DES. Human corneal epithelial cells (HCECs) were used in the WST-8 assay to determine the safe dose of EGCG. Lipopolysaccharide-stimulated HCECs showing inflammation were treated with EGCG/HA. The expression of IL-1ß, IL-6, IL-8, and TNF-α was assessed by real-time PCR and AT physical properties such as the viscosity, osmolarity, and pH were examined. AT containing EGCG and HA were topically administered in a rabbit DES model established by treatment with 0.1% benzalkonium chloride (BAC). Tear secretion was assessed and fluorescein, H&E, and TUNEL staining were performed. Inflammatory cytokine levels in the corneas were also examined. The non-toxic optimal concentration of EGCG used for the treatment of HCECs in vitro was 10 μg/mL. The expression of several inflammatory genes, including IL-1ß, IL-6, IL-8, and TNF-α, was significantly inhibited in inflamed HCECs treated with 10 μg/mL EGCG and 0.1% (w/v) HA (E10/HA) compared to that in inflamed HCECs treated with either EGCG or HA alone. AT containing E10/HA mimic human tears, with similar osmolarity and viscosity and a neutral pH. Fluorescence examination of the ocular surface of mouse eyes showed that HA increased drug retention on the ocular surface. Topical treatment of DES rabbits with AT plus E10/HA increased tear secretion, reduced corneal epithelial damage, and maintained the epithelial layers and stromal structure. Moreover, the corneas of the E10/HA-treated rabbits showed fewer apoptotic cells, lower inflammation, and decreased IL-6, IL-8, and TNF-α levels. In conclusion, we showed that AT plus E10/HA had anti-inflammatory and mucoadhesive properties when used as topical eye drops and were effective for treating DES in rabbits.

  20. Extruding plastic scintillator at Fermilab

    International Nuclear Information System (INIS)

    Pla-Dalmau, Anna; Bross, Alain D.; Rykalin, Viktor V.

    2003-01-01

    An understanding of the costs involved in the production of plastic scintillators and the development of a less expensive material have become necessary with the prospects of building very large plastic scintillation detectors. Several factors contribute to the high cost of plastic scintillating sheets, but the principal reason is the labor-intensive nature of the manufacturing process. In order to significantly lower the costs, the current casting procedures had to be abandoned. Since polystyrene is widely used in the consumer industry, the logical path was to investigate the extrusion of commercial-grade polystyrene pellets with dopants to yield high quality plastic scintillator. This concept was tested and high quality extruded plastic scintillator was produced. The D0 and MINOS experiments are already using extruded scintillator strips in their detectors. An extrusion line has recently been installed at Fermilab in collaboration with NICADD (Northern Illinois Center for Accelerator and Detector Development). This new facility will serve to further develop and improve extruded plastic scintillator. This paper will discuss the characteristics of extruded plastic scintillator and its raw materials, the different manufacturing techniques and the current R andD program at Fermilab

  1. Applications and societal benefits of plastics.

    Science.gov (United States)

    Andrady, Anthony L; Neal, Mike A

    2009-07-27

    This article explains the history, from 1600 BC to 2008, of materials that are today termed 'plastics'. It includes production volumes and current consumption patterns of five main commodity plastics: polypropylene, polyethylene, polyvinyl chloride, polystyrene and polyethylene terephthalate. The use of additives to modify the properties of these plastics and any associated safety, in use, issues for the resulting polymeric materials are described. A comparison is made with the thermal and barrier properties of other materials to demonstrate the versatility of plastics. Societal benefits for health, safety, energy saving and material conservation are described, and the particular advantages of plastics in society are outlined. Concerns relating to littering and trends in recycling of plastics are also described. Finally, we give predictions for some of the potential applications of plastic over the next 20 years.

  2. Periphytic algal community in artificial and natural substratum in a tributary of the Rosana reservoir (Corvo Stream, Paraná State, Brazil - doi: 10.4025/actascibiolsci.v32i4.4627 Periphytic algal community in artificial and natural substratum in a tributary of the Rosana reservoir (Corvo Stream, Paraná State, Brazil - doi: 10.4025/actascibiolsci.v32i4.4627

    Directory of Open Access Journals (Sweden)

    Liliana Rodrigues

    2010-11-01

    Full Text Available Periphytic algal community in artificial and natural substratum in a tributary of the Rosana reservoir (Corvo Stream, Paraná State, Brazil. This study evaluated the heterogeneity in periphytic algal community, under the influence of time colonization on artificial substratum. We also examined which abiotic variables most influenced the community in natural and artificial substratum. Egeria najas Planchon was used as natural substratum, and a plastic plant, as artificial. This experiment was carried out in a lateral arm from Rosana Reservoir, formed by Corvo Stream (Paranapanema river basin, in the period from November 21st to December 12nd, 2003, characterized as a warm and rainy period. Changes in species composition were assessed using the similarity indices. 495 taxa were registered in the phycoperiphytic community, distributed in 133 genera and 11 classes. Zygnemaphyceae, Bacillariophyceae, Chlorophyceae and Cyanophyceae presented higher species number, in both substrata. Staurodesmus, Closterium, Staurastrum and Cosmarium (Desmidiales; Gomphonema and Eunotia (Pennales; Characium, Scenedesmus and Desmodesmus (Chlorococcales; Anabaena and Aphanocapsa (Nostocales and Chroococcales, respectively were the most species-rich genera. The epiphytic community reached the highest species richness in the 15th successional day. Regardless the substratum type, the number of species was probably related to the high concentrations of nutrients (phosphorus and nitrogen.Periphytic algal community in artificial and natural substratum in a tributary of the Rosana reservoir (Corvo Stream, Paraná State, Brazil. This study evaluated the heterogeneity in periphytic algal community, under the influence of time colonization on artificial substratum. We also examined which abiotic variables most influenced the community in natural and artificial substratum. Egeria najas Planchon was used as natural substratum, and a plastic plant, as artificial. This experiment was

  3. Plastic pollutants in water environment

    Directory of Open Access Journals (Sweden)

    Mrowiec Bożena

    2017-12-01

    Full Text Available Nowadays, wide applications of plastics result in plastic waste being present in the water environment in a wide variety of sizes. Plastic wastes are in water mainly as microplastics (the size range of 1 nm to < 5 mm. Microplastics have been recognized as an emerging threat, as well as ecotoxicological and ecological risk for water ecosystems. In this review are presented some of the physicochemical properties of plastic materials that determine their toxic effect on the aquatic environment. Wastewater treatment plants (WWTPs are mentioned as one of main sources of microplastics introduced into fresh water, and rivers are the pathways for the transportation of the pollutants to seas and oceans. But, effluents from tertiary wastewater treatment facilities can contain only minimally microplastic loads. The issue of discharge reduction of plastic pollutants into water environment needs activities in the scope of efficient wastewater treatment, waste disposal, recycling of plastic materials, education and public involvement.

  4. Track treeing mechanism and plastic zone in solid Part 1: Initial development of plastic zone

    International Nuclear Information System (INIS)

    Li Boyang

    2008-01-01

    After neutron exposure and chemical etching in advance, latent tracks of recoil nucleon develop into pits on CR39 surface. During electrochemical etching, plastic zone is formed at top of pits. Some pits develop into tree cracks in the initial stage of plastic zone development. Physical and mathematical model of crack and plastic zone is proposed; parameter of development free path of plastic zone is presented. Based on integration of elementary theories the stress analysis is build up; based on analyses of measured parameters, a set of common relations between parameters is obtained. Integrate parameter analysis and stress analysis, depth of plastic zone development, law and phenomenon in experimental data can be interpreted completely

  5. Accumulation of plastic-derived chemicals in tissues of seabirds ingesting marine plastics.

    Science.gov (United States)

    Tanaka, Kosuke; Takada, Hideshige; Yamashita, Rei; Mizukawa, Kaoruko; Fukuwaka, Masa-aki; Watanuki, Yutaka

    2013-04-15

    We analyzed polybrominated diphenyl ethers (PBDEs) in abdominal adipose of oceanic seabirds (short-tailed shearwaters, Puffinus tenuirostris) collected in northern North Pacific Ocean. In 3 of 12 birds, we detected higher-brominated congeners (viz., BDE209 and BDE183), which are not present in the natural prey (pelagic fish) of the birds. The same compounds were present in plastic found in the stomachs of the 3 birds. These data suggested the transfer of plastic-derived chemicals from ingested plastics to the tissues of marine-based organisms. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Extraction of Organochlorine Pesticides from Plastic Pellets and Plastic Type Analysis.

    Science.gov (United States)

    Pflieger, Marilyne; Makorič, Petra; Kovač Viršek, Manca; Koren, Špela

    2017-07-01

    Plastic resin pellets, categorized as microplastics (≤5 mm in diameter), are small granules that can be unintentionally released to the environment during manufacturing and transport. Because of their environmental persistence, they are widely distributed in the oceans and on beaches all over the world. They can act as a vector of potentially toxic organic compounds (e.g., polychlorinated biphenyls) and might consequently negatively affect marine organisms. Their possible impacts along the food chain are not yet well understood. In order to assess the hazards associated with the occurrence of plastic pellets in the marine environment, it is necessary to develop methodologies that allow for rapid determination of associated organic contaminant levels. The present protocol describes the different steps required for sampling resin pellets, analyzing adsorbed organochlorine pesticides (OCPs) and identifying the plastic type. The focus is on the extraction of OCPs from plastic pellets by means of a pressurized fluid extractor (PFE) and on the polymer chemical analysis applying Fourier Transform-InfraRed (FT-IR) spectroscopy. The developed methodology focuses on 11 OCPs and related compounds, including dichlorodiphenyltrichloroethane (DDT) and its two main metabolites, lindane and two production isomers, as well as the two biologically active isomers of technical endosulfan. This protocol constitutes a simple and rapid alternative to existing methodology for evaluating the concentration of organic contaminants adsorbed on plastic pieces.

  7. Computational strain gradient crystal plasticity

    DEFF Research Database (Denmark)

    Niordson, Christian Frithiof; Kysar, Jeffrey W.

    2014-01-01

    A numerical method for viscous strain gradient crystal plasticity theory is presented, which incorporates both energetic and dissipative gradient effects. The underlying minimum principles are discussed as well as convergence properties of the proposed finite element procedure. Three problems...... of plane crystal plasticity are studied: pure shear of a single crystal between rigid platens as well as plastic deformation around cylindrical voids in hexagonal close packed and face centered cubic crystals. Effective in-plane constitutive slip parameters for plane strain deformation of specifically...... oriented face centered cubic crystals are developed in terms of the crystallographic slip parameters. The effect on geometrically necessary dislocation structures introduced by plastic deformation is investigated as a function of the ratio of void radius to plasticity length scale....

  8. Imaging brain plasticity after trauma

    Institute of Scientific and Technical Information of China (English)

    Zhifeng Kou; Armin Iraji

    2014-01-01

    The brain is highly plastic after stroke or epilepsy;however, there is a paucity of brain plasticity investigation after traumatic brain injury (TBI). This mini review summarizes the most recent evidence of brain plasticity in human TBI patients from the perspective of advanced magnetic resonance imaging. Similar to other forms of acquired brain injury, TBI patients also demonstrat-ed both structural reorganization as well as functional compensation by the recruitment of other brain regions. However, the large scale brain network alterations after TBI are still unknown, and the ifeld is still short of proper means on how to guide the choice of TBI rehabilitation or treat-ment plan to promote brain plasticity. The authors also point out the new direction of brain plas-ticity investigation.

  9. Artificial Hydration and Nutrition

    Science.gov (United States)

    ... Crisis Situations Pets and Animals myhealthfinder Food and Nutrition Healthy Food Choices Weight Loss and Diet Plans ... Your Health Resources Healthcare Management Artificial Hydration and Nutrition Artificial Hydration and Nutrition Share Print Patients who ...

  10. Artificial Evolution for the Detection of Group Identities in Complex Artificial Societies

    DEFF Research Database (Denmark)

    Grappiolo, Corrado; Togelius, Julian; Yannakakis, Georgios N.

    2013-01-01

    This paper aims at detecting the presence of group structures in complex artificial societies by solely observing and analysing the interactions occurring among the artificial agents. Our approach combines: (1) an unsupervised method for clustering interactions into two possible classes, namely in...

  11. Artificial intelligence

    International Nuclear Information System (INIS)

    Perret-Galix, D.

    1992-01-01

    A vivid example of the growing need for frontier physics experiments to make use of frontier technology is in the field of artificial intelligence and related themes. This was reflected in the second international workshop on 'Software Engineering, Artificial Intelligence and Expert Systems in High Energy and Nuclear Physics' which took place from 13-18 January at France Telecom's Agelonde site at La Londe des Maures, Provence. It was the second in a series, the first having been held at Lyon in 1990

  12. Isolation and characterization of soluble sulfated polysaccharide from the red seaweed Glucaric cornea

    International Nuclear Information System (INIS)

    Melo, Marcia R.S.; Freitas, Ana L.P.; Feitosa, Judith P.A.; Paula, Regina C.M. de

    2001-01-01

    The composition, structure and rheological properties of soluble sulphated polysaccharide Glucaric cornea from Brazilian red seaweeds were investigated. The main components of polysaccharide were 3,6-anhydrogalactose (24.7%) and galactose (64.6%). In addition, minor components as 6-O-methyl-galactose (8.5%), glucose (1.5%), xylose (0.7%) and sulfated groups (4.8%) were detected. Comparison between sulphates content determined by Ft-IR spectroscopy and micro elemental analysis was made. Data from 13 C NMR and FT-IR provided evidence of sulphation in C-4 and C-6 of galactose. No gelation with 1.5, 2.0 and 3.0 % (w/v) aqueous solution was observed, even cooled up to 4 deg C. GPC indicated two majors polysaccharide fractions of M pk 7.4 x 10 4 and 1.8 x 10 4 g/mol and a minor fraction of M pk 2.1 x 10 6 g/mol. (author)

  13. Constraints on the evolution of phenotypic plasticity

    DEFF Research Database (Denmark)

    Murren, Courtney J; Auld, Josh R.; Callahan, Hilary S

    2015-01-01

    Phenotypic plasticity is ubiquitous and generally regarded as a key mechanism for enabling organisms to survive in the face of environmental change. Because no organism is infinitely or ideally plastic, theory suggests that there must be limits (for example, the lack of ability to produce...... an optimal trait) to the evolution of phenotypic plasticity, or that plasticity may have inherent significant costs. Yet numerous experimental studies have not detected widespread costs. Explicitly differentiating plasticity costs from phenotype costs, we re-evaluate fundamental questions of the limits...... to the evolution of plasticity and of generalists vs specialists. We advocate for the view that relaxed selection and variable selection intensities are likely more important constraints to the evolution of plasticity than the costs of plasticity. Some forms of plasticity, such as learning, may be inherently...

  14. Descemet's stripping-automated endothelial keratoplasty for symptomatic thioridazine deposits in the cornea

    Directory of Open Access Journals (Sweden)

    Masoumeh Mohebbi

    2017-01-01

    Full Text Available The aim of this study was to use Descemet's Stripping-automated Endothelial Keratoplasty (DSAEK as a novel treatment to remove thioridazine corneal deposits. A 53-year-old female presented with a 3-month history of visual loss and glare. She had been taking thioridazine (100 mg/day for 1 year for a psychiatric disorder. Dense yellowish-brown deposits had developed in the posterior stroma. Thioridazine was discontinued, and she was switched to fluoxetine. One year after discontinuation of thioridazine, her symptoms and signs did not resolve. Standard DSAEK was performed on her left eye. Two weeks after DSAEK, an anterior subcapsular cataract was detected in the same eye. Phacoemulsification and intraocular lens implantation were performed after 3 months. The left cornea became completely clear after DSAEK, and the patient's best-corrected visual acuity improved from 20/40 to 20/20 at 1 month after cataract surgery. All-visual symptoms such as glare and halos improved postoperatively. We suggest that DSAEK can be used as a novel treatment to reduce vision problems caused by thioridazine-induced corneal deposits.

  15. Recycling of packing plastics

    International Nuclear Information System (INIS)

    Gintenreiter-Koegl, S.

    2001-05-01

    The ordinance on the avoidance of packaging waste was a serious intervention in the public and private waste management in Austria. Above all the high expenses for an overall packaging waste collection and the recycling of packaging plastics were criticized. The landfill ordinance comes into force in 2004 and this means another major change in the Austrian waste management system. In the course of this change the overall collection and the recycling and recovery of waste streams, especially of the high caloric plastics waste, have to be discussed again. The goal of this work was on the one hand to develop and adapt the hydrocracking process for the recovery of mixed plastics waste and to show a possible application in Austria. On the other hand the work shows the technical, ecological and economical conditions for packaging plastics recycling and recovery in order to find optimum applications for the processes and to examine their contribution to a sustainable development. A hydrocracking test plant for the processing of mixed plastic wastes was built and had been running for about three years. The tests were carried out successfully and the suitability of the technology for the recovery of packaging plastics could be shown. Results show at least a 35 % yield of fuel. The hydrocracking technology is quite common in the oil industries and therefore an integration on a refinery site is suggested. (author)

  16. Radiation induced change in the affinity of a plastic resin to chlorine contained in artificial tap water

    International Nuclear Information System (INIS)

    Fujiyoshi, Ryoko; Sawamura, Sadashi; Katayama, Meiseki

    1985-01-01

    γ-Radiation curing of a polyacetal resin was attempted in order to eliminate the unsuitable property for the joints of tap water pipes. In the case of non-irradiated resin, almost all available chlorine (AC) contained in usual tap water disappeared. γ-Irradiation of the resin showed an indirect effect on eliminating such a property; that is, a decrease in the amount of AC from artificial tap water (test solution) showed a decrease to JIS (Japan Industrial Standards) level of requirement at certain absorption doses. However, it was also found that the decrease in the amount of AC from the test solution increased with time after γ-irradiation. (author)

  17. Influence of preliminary plastic deformation on plasticity characteristics and structure of armco-iron

    International Nuclear Information System (INIS)

    Vergazov, A.N.; Rybin, V.V.; Meshkov, Yu.Ya.; Moskvina, V.A.; Serditova, T.N.

    1990-01-01

    Effect of preliminary plastic deformation (PPD) by drawing on the maximum plasticity characteristics (critical rupture strain) ε c , general δ and uniform δ p relative elongation and on the structure of armco-iron in a wide range of PPD degree change (e=0-4.6) is studied. It is ascertained that with e growth the metal plastic properties at T test =77 and 293 K change in a different way. In particular, the critical strain ε c increases monotonously at 77 K and reduces at 293 K. It is shown that all changes of mechanical characteristics observed with e increase are conditioned by the development of fragmentation process in armco-iron. The data obtained are discussed from the veiwpoint of the developed plastic deformation physics concepts

  18. Diverse spike-timing-dependent plasticity based on multilevel HfO x memristor for neuromorphic computing

    Science.gov (United States)

    Lu, Ke; Li, Yi; He, Wei-Fan; Chen, Jia; Zhou, Ya-Xiong; Duan, Nian; Jin, Miao-Miao; Gu, Wei; Xue, Kan-Hao; Sun, Hua-Jun; Miao, Xiang-Shui

    2018-06-01

    Memristors have emerged as promising candidates for artificial synaptic devices, serving as the building block of brain-inspired neuromorphic computing. In this letter, we developed a Pt/HfO x /Ti memristor with nonvolatile multilevel resistive switching behaviors due to the evolution of the conductive filaments and the variation in the Schottky barrier. Diverse state-dependent spike-timing-dependent-plasticity (STDP) functions were implemented with different initial resistance states. The measured STDP forms were adopted as the learning rule for a three-layer spiking neural network which achieves a 75.74% recognition accuracy for MNIST handwritten digit dataset. This work has shown the capability of memristive synapse in spiking neural networks for pattern recognition application.

  19. Plastic accumulation in the Mediterranean sea.

    Directory of Open Access Journals (Sweden)

    Andrés Cózar

    Full Text Available Concentrations of floating plastic were measured throughout the Mediterranean Sea to assess whether this basin can be regarded as a great accumulation region of plastic debris. We found that the average density of plastic (1 item per 4 m2, as well as its frequency of occurrence (100% of the sites sampled, are comparable to the accumulation zones described for the five subtropical ocean gyres. Plastic debris in the Mediterranean surface waters was dominated by millimeter-sized fragments, but showed a higher proportion of large plastic objects than that present in oceanic gyres, reflecting the closer connection with pollution sources. The accumulation of floating plastic in the Mediterranean Sea (between 1,000 and 3,000 tons is likely related to the high human pressure together with the hydrodynamics of this semi-enclosed basin, with outflow mainly occurring through a deep water layer. Given the biological richness and concentration of economic activities in the Mediterranean Sea, the affects of plastic pollution on marine and human life are expected to be particularly frequent in this plastic accumulation region.

  20. Plastic Accumulation in the Mediterranean Sea

    KAUST Repository

    Có zar, André s; Sanz-Martí n, Marina; Martí , Elisa; Gonzá lez-Gordillo, J. Ignacio; Ubeda, Bá rbara; Gá lvez, José Á .; Irigoien, Xabier; Duarte, Carlos M.

    2015-01-01

    Concentrations of floating plastic were measured throughout the Mediterranean Sea to assess whether this basin can be regarded as a great accumulation region of plastic debris. We found that the average density of plastic (1 item per 4 m2), as well as its frequency of occurrence (100% of the sites sampled), are comparable to the accumulation zones described for the five subtropical ocean gyres. Plastic debris in the Mediterranean surface waters was dominated by millimeter-sized fragments, but showed a higher proportion of large plastic objects than that present in oceanic gyres, reflecting the closer connection with pollution sources. The accumulation of floating plastic in the Mediterranean Sea (between 1,000 and 3,000 tons) is likely related to the high human pressure together with the hydrodynamics of this semi-enclosed basin, with outflow mainly occurring through a deep water layer. Given the biological richness and concentration of economic activities in the Mediterranean Sea, the affects of plastic pollution on marine and human life are expected to be particularly frequent in this plastic accumulation region.

  1. Nano-plastics in the aquatic environment.

    Science.gov (United States)

    Mattsson, K; Hansson, L-A; Cedervall, T

    2015-10-01

    The amount of plastics released to the environment in modern days has increased substantially since the development of modern plastics in the early 1900s. As a result, concerns have been raised by the public about the impact of plastics on nature and on, specifically, aquatic wildlife. Lately, much attention has been paid to macro- and micro-sized plastics and their impact on aquatic organisms. However, micro-sized plastics degrade subsequently into nano-sizes whereas nano-sized particles may be released directly into nature. Such particles have a different impact on aquatic organisms than larger pieces of plastic due to their small size, high surface curvature, and large surface area. This review describes the possible sources of nano-sized plastic, its distribution and behavior in nature, the impact of nano-sized plastic on the well-being of aquatic organisms, and the difference of impact between nano- and micro-sized particles. We also identify research areas which urgently need more attention and suggest experimental methods to obtain useful data.

  2. Integrating Hebbian and homeostatic plasticity: introduction.

    Science.gov (United States)

    Fox, Kevin; Stryker, Michael

    2017-03-05

    Hebbian plasticity is widely considered to be the mechanism by which information can be coded and retained in neurons in the brain. Homeostatic plasticity moves the neuron back towards its original state following a perturbation, including perturbations produced by Hebbian plasticity. How then does homeostatic plasticity avoid erasing the Hebbian coded information? To understand how plasticity works in the brain, and therefore to understand learning, memory, sensory adaptation, development and recovery from injury, requires development of a theory of plasticity that integrates both forms of plasticity into a whole. In April 2016, a group of computational and experimental neuroscientists met in London at a discussion meeting hosted by the Royal Society to identify the critical questions in the field and to frame the research agenda for the next steps. Here, we provide a brief introduction to the papers arising from the meeting and highlight some of the themes to have emerged from the discussions.This article is part of the themed issue 'Integrating Hebbian and homeostatic plasticity'. © 2017 The Author(s).

  3. Plastic Accumulation in the Mediterranean Sea

    KAUST Repository

    Cózar, Andrés

    2015-04-01

    Concentrations of floating plastic were measured throughout the Mediterranean Sea to assess whether this basin can be regarded as a great accumulation region of plastic debris. We found that the average density of plastic (1 item per 4 m2), as well as its frequency of occurrence (100% of the sites sampled), are comparable to the accumulation zones described for the five subtropical ocean gyres. Plastic debris in the Mediterranean surface waters was dominated by millimeter-sized fragments, but showed a higher proportion of large plastic objects than that present in oceanic gyres, reflecting the closer connection with pollution sources. The accumulation of floating plastic in the Mediterranean Sea (between 1,000 and 3,000 tons) is likely related to the high human pressure together with the hydrodynamics of this semi-enclosed basin, with outflow mainly occurring through a deep water layer. Given the biological richness and concentration of economic activities in the Mediterranean Sea, the affects of plastic pollution on marine and human life are expected to be particularly frequent in this plastic accumulation region.

  4. Plastic accumulation in the Mediterranean sea.

    Science.gov (United States)

    Cózar, Andrés; Sanz-Martín, Marina; Martí, Elisa; González-Gordillo, J Ignacio; Ubeda, Bárbara; Gálvez, José Á; Irigoien, Xabier; Duarte, Carlos M

    2015-01-01

    Concentrations of floating plastic were measured throughout the Mediterranean Sea to assess whether this basin can be regarded as a great accumulation region of plastic debris. We found that the average density of plastic (1 item per 4 m2), as well as its frequency of occurrence (100% of the sites sampled), are comparable to the accumulation zones described for the five subtropical ocean gyres. Plastic debris in the Mediterranean surface waters was dominated by millimeter-sized fragments, but showed a higher proportion of large plastic objects than that present in oceanic gyres, reflecting the closer connection with pollution sources. The accumulation of floating plastic in the Mediterranean Sea (between 1,000 and 3,000 tons) is likely related to the high human pressure together with the hydrodynamics of this semi-enclosed basin, with outflow mainly occurring through a deep water layer. Given the biological richness and concentration of economic activities in the Mediterranean Sea, the affects of plastic pollution on marine and human life are expected to be particularly frequent in this plastic accumulation region.

  5. Plastic Accumulation in the Mediterranean Sea

    Science.gov (United States)

    Cózar, Andrés; Sanz-Martín, Marina; Martí, Elisa; González-Gordillo, J. Ignacio; Ubeda, Bárbara; Gálvez, José Á.; Irigoien, Xabier; Duarte, Carlos M.

    2015-01-01

    Concentrations of floating plastic were measured throughout the Mediterranean Sea to assess whether this basin can be regarded as a great accumulation region of plastic debris. We found that the average density of plastic (1 item per 4 m2), as well as its frequency of occurrence (100% of the sites sampled), are comparable to the accumulation zones described for the five subtropical ocean gyres. Plastic debris in the Mediterranean surface waters was dominated by millimeter-sized fragments, but showed a higher proportion of large plastic objects than that present in oceanic gyres, reflecting the closer connection with pollution sources. The accumulation of floating plastic in the Mediterranean Sea (between 1,000 and 3,000 tons) is likely related to the high human pressure together with the hydrodynamics of this semi-enclosed basin, with outflow mainly occurring through a deep water layer. Given the biological richness and concentration of economic activities in the Mediterranean Sea, the affects of plastic pollution on marine and human life are expected to be particularly frequent in this plastic accumulation region. PMID:25831129

  6. Americium behaviour in plastic vessels

    Energy Technology Data Exchange (ETDEWEB)

    Legarda, F.; Herranz, M. [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain); Idoeta, R., E-mail: raquel.idoeta@ehu.e [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain); Abelairas, A. [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain)

    2010-07-15

    The adsorption of {sup 241}Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of {sup 241}Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of {sup 241}Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification.

  7. Americium behaviour in plastic vessels

    International Nuclear Information System (INIS)

    Legarda, F.; Herranz, M.; Idoeta, R.; Abelairas, A.

    2010-01-01

    The adsorption of 241 Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of 241 Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of 241 Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification.

  8. Goldmann tonometry tear film error and partial correction with a shaped applanation surface.

    Science.gov (United States)

    McCafferty, Sean J; Enikov, Eniko T; Schwiegerling, Jim; Ashley, Sean M

    2018-01-01

    The aim of the study was to quantify the isolated tear film adhesion error in a Goldmann applanation tonometer (GAT) prism and in a correcting applanation tonometry surface (CATS) prism. The separation force of a tonometer prism adhered by a tear film to a simulated cornea was measured to quantify an isolated tear film adhesion force. Acrylic hemispheres (7.8 mm radius) used as corneas were lathed over the apical 3.06 mm diameter to simulate full applanation contact with the prism surface for both GAT and CATS prisms. Tear film separation measurements were completed with both an artificial tear and fluorescein solutions as a fluid bridge. The applanation mire thicknesses were measured and correlated with the tear film separation measurements. Human cadaver eyes were used to validate simulated cornea tear film separation measurement differences between the GAT and CATS prisms. The CATS prism tear film adhesion error (2.74±0.21 mmHg) was significantly less than the GAT prism (4.57±0.18 mmHg, p film adhesion error was independent of applanation mire thickness ( R 2 =0.09, p =0.04). Fluorescein produces more tear film error than artificial tears (+0.51±0.04 mmHg; p film adhesion error (1.40±0.51 mmHg) was significantly less than that of the GAT prism (3.30±0.38 mmHg; p =0.002). Measured GAT tear film adhesion error is more than previously predicted. A CATS prism significantly reduced tear film adhesion error bŷ41%. Fluorescein solution increases the tear film adhesion compared to artificial tears, while mire thickness has a negligible effect.

  9. Use of glycerol-preserved corneas for corneal transplants

    Directory of Open Access Journals (Sweden)

    Neeti Gupta

    2017-01-01

    Full Text Available Purpose: This study was carried out to see the results of glycerol-preserved cornea (GPC in emergency situation when fresh corneal tissue was not available. The aim was to study the outcome of corneal transplantation using GPC. Methods: This was a retrospective study. The medical records of all the patients were reviewed, who underwent keratoplasty using “GPC” during the period from October 2011 to December 2015. The indication of keratoplasty, duration of preservation of the GPC, and its outcome were analyzed. Descriptive statistics were applied. Results: Out of the 222 penetrating keratoplasty (PKP performed over the study period, the GPC was used in 34 patients (males = 31, 91.2% aged 15–74 years. Therapeutic keratoplasty was performed in all cases in this cohort except one in which tectonic keratoplasty was done. The primary indication of PKP (91.2% was infectious keratitis. Of these, 20 (64.5% patients presented with perforated corneal ulcers. Post-PKP, ocular anatomy was preserved in 91.2%, and visual acuity of perception of light positive and accurate projection of rays in all the quadrants was obtained in 76.5% cases. Complications included glaucoma (n = 12, 35.1%, phthisis bulbi (n = 2, 5.9%, and graft reinfection and endophthalmitis after PKP (n = 1, 2.9%. The secondary procedure post-GPC and PKP were trabeculectomy with mitomycin C (n = 7, 58.3% in patients not controlled on topical antiglaucoma medication. Optical keratoplasty was performed in (n = 3 8.8% patients and triple procedure in (n = 2 5.8% patients with good visual acuity postprocedure. Conclusions: Acellular GPCs are useful in emergency keratoplasty to avoid loss of vision and can save the eye.

  10. The use of Wavelight® Contoura to create a uniform cornea: the LYRA protocol. Part 3: the results of 50 treated eyes

    Directory of Open Access Journals (Sweden)

    Motwani M

    2017-05-01

    Full Text Available Manoj Motwani Motwani LASIK Institute, San Diego, CA, USA Purpose: To demonstrate how using the Wavelight Contoura measured astigmatism and axis eliminates corneal astigmatism and creates uniformly shaped corneas. Patients and methods: A retrospective analysis was conducted of the first 50 eyes to have bilateral full WaveLight® Contoura LASIK correction of measured astigmatism and axis (vs conventional manifest refraction, using the Layer Yolked Reduction of Astigmatism Protocol in all cases. All patients had astigmatism corrected, and had at least 1 week of follow-up. Accuracy to desired refractive goal was assessed by postoperative refraction, aberration reduction via calculation of polynomials, and postoperative visions were analyzed as a secondary goal. Results: The average difference of astigmatic power from manifest to measured was 0.5462D (with a range of 0–1.69D, and the average difference of axis was 14.94° (with a range of 0°–89°. Forty-seven of 50 eyes had a goal of plano, 3 had a monovision goal. Astigmatism was fully eliminated from all but 2 eyes, and 1 eye had regression with astigmatism. Of the eyes with plano as the goal, 80.85% were 20/15 or better, and 100% were 20/20 or better. Polynomial analysis postoperatively showed that at 6.5 mm, the average C3 was reduced by 86.5% and the average C5 by 85.14%. Conclusions: Using WaveLight® Contoura measured astigmatism and axis removes higher order aberrations and allows for the creation of a more uniform cornea with accurate removal of astigmatism, and reduction of aberration polynomials. WaveLight® Contoura successfully links the refractive correction layer and aberration repair layer using the Layer Yolked Reduction of Astigmatism Protocol to demonstrate how aberration removal can affect refractive correction. Keywords: WaveLight Contoura, topographic guided ablation, LASIK, PRK, uniform cornea, Contoura with LYRA Protocol, measured astigmatism

  11. Operant Conditioning: A Minimal Components Requirement in Artificial Spiking Neurons Designed for Bio-Inspired Robot’s Controller

    Directory of Open Access Journals (Sweden)

    André eCyr

    2014-07-01

    Full Text Available We demonstrate the operant conditioning (OC learning process within a basic bio-inspired robot controller paradigm, using an artificial spiking neural network (ASNN with minimal component count as artificial brain. In biological agents, OC results in behavioral changes that are learned from the consequences of previous actions, using progressive prediction adjustment triggered by reinforcers. In a robotics context, virtual and physical robots may benefit from a similar learning skill when facing unknown environments with no supervision. In this work, we demonstrate that a simple ASNN can efficiently realise many OC scenarios. The elementary learning kernel that we describe relies on a few critical neurons, synaptic links and the integration of habituation and spike-timing dependent plasticity (STDP as learning rules. Using four tasks of incremental complexity, our experimental results show that such minimal neural component set may be sufficient to implement many OC procedures. Hence, with the described bio-inspired module, OC can be implemented in a wide range of robot controllers, including those with limited computational resources.

  12. Examination of mitral regurgitation with a goat heart model for the development of intelligent artificial papillary muscle.

    Science.gov (United States)

    Shiraishi, Y; Yambe, T; Yoshizawa, M; Hashimoto, H; Yamada, A; Miura, H; Hashem, M; Kitano, T; Shiga, T; Homma, D

    2012-01-01

    Annuloplasty for functional mitral or tricuspid regurgitation has been made for surgical restoration of valvular diseases. However, these major techniques may sometimes be ineffective because of chamber dilation and valve tethering. We have been developing a sophisticated intelligent artificial papillary muscle (PM) by using an anisotropic shape memory alloy fiber for an alternative surgical reconstruction of the continuity of the mitral structural apparatus and the left ventricular myocardium. This study exhibited the mitral regurgitation with regard to the reduction in the PM tension quantitatively with an originally developed ventricular simulator using isolated goat hearts for the sophisticated artificial PM. Aortic and mitral valves with left ventricular free wall portions of isolated goat hearts (n=9) were secured on the elastic plastic membrane and statically pressurized, which led to valvular leaflet-papillary muscle positional change and central mitral regurgitation. PMs were connected to the load cell, and the relationship between the tension of regurgitation and PM tension were measured. Then we connected the left ventricular specimen model to our hydraulic ventricular simulator and achieved hemodynamic simulation with the controlled tension of PMs.

  13. Sustainable reverse logistics for household plastic waste

    NARCIS (Netherlands)

    Bing, X.

    2014-01-01

    Summary of the thesis titled “Sustainable Reverse Logistics for Household Plastic Waste”

    PhD Candidate: Xiaoyun Bing

    Recycled plastic can be used in the manufacturing of plastic products to reduce the use of virgin plastics material. The cost of recycled plastics is usually lower

  14. Size effects in crystal plasticity

    DEFF Research Database (Denmark)

    Borg, Ulrik

    2007-01-01

    Numerical analyses of plasticity size effects have been carried out for different problems using a developed strain gradient crystal plasticiy theory. The theory employs higher order stresses as work conjugates to slip gradients and uses higher order boundary conditions. Problems on localization...... of plastic flow in a single crystal, grain boundary effects in a bicrystal, and grain size effects in a polycrystal are studied. Single crystals containing micro-scale voids have also been analyzed at different loading conditions with focus on the stress and deformation fields around the voids, on void...... growth and interaction between neighboring voids, and on a comparison between the developed strain gradient crystal plasticity theory and a discrete dislocation plasticity theory. Furthermore, voids and rigid inclusions in isotropic materials have been studied using a strain gradient plasticity theory...

  15. SYNTHESIS AND CHARACTERIZATION OF BIODEGRDABLE PLASTIC FROM CASAVA STARCH AND ALOE VERA EXTRACT WITH GLYCEROL PLASTICIZER

    Directory of Open Access Journals (Sweden)

    Mery Apriyani

    2016-05-01

    Full Text Available Synthesis and characterizations of Biodegradable Plastic made of Cassava Waste Starch, glycerol, acetic acid and Aloe vera extract has done. The aims of this research are to study the influence of addition of aloe vera extract in plastics mechanics properties, water vapor transmission rate and biodegradation. There are five main steps in this research, extraction of aloe vera, cassava starch preparation from cassava waste, preparations, characterization and biodegradability study of biodegradable plastic. The addition variations of aloe vera extract that used in this research are 0.01; 0.03; 0.05; 0.07 and 0.14 grams. Results showed that the addition of aloe Vera tends to increased biodegrable plastic thickness to 0.01 mm and elongation to 32.07%. However, biodegradable plastic tensile strength tends to decreased to 23.95 Mpa. Optimum tensile strength is 3.90 Mpa and elongation is 34.43%. Optimum water vapor transmission rate is 2.40 g/m2hours. Biodegradation study of biodegradable plastic showed that addition of aloe vera extract doesn’t significantly influence in plastic degradations.

  16. The Japanese artificial organs scene: current status.

    Science.gov (United States)

    Mitamura, Yoshinori; Murabayashi, Shun

    2005-08-01

    Artificial organs and regenerative medicine are the subjects of very active research and development (R&D) in Japan and various artificial organs are widely used in patients. Results of the R&D are presented at the annual conference of the Japanese Society for Artificial Organs (JSAO). Progress in the fields of artificial organs and regenerative medicine are reviewed annually in the Japanese Journal of Artificial Organs. The official English-language journal of JSAO, Journal of Artificial Organs, also publishes many original articles by Japanese researchers. Although the annual conference and the publications of JSAO provide the world with update information on artificial organs and regenerative medicine in Japan, the information is not always understood appropriately in the rest of the world, mainly due to language problems. This article therefore introduces the current status of artificial organs and regenerative medicine in Japan. Artificial hearts and metabolic support systems are reviewed here and other interesting areas such as regenerative medicine can be found elsewhere.

  17. Americium behaviour in plastic vessels.

    Science.gov (United States)

    Legarda, F; Herranz, M; Idoeta, R; Abelairas, A

    2010-01-01

    The adsorption of (241)Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of (241)Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of (241)Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification. Copyright 2009 Elsevier Ltd. All rights reserved.

  18. Plastics control paraffin buildup

    Energy Technology Data Exchange (ETDEWEB)

    1965-06-01

    Paraffin buildup in producing oil wells has been virtually eliminated by the use of plastic-coated sucker rods. The payout of the plasticing process is generally reached in less than a year, and the paraffin buildup may be inhibited for 10 yr or longer. Most of the plants applying plastic coatings to sucker rods are now fully automated, though a few still offer the hand-sprayed coating that some operators prefer. The several steps involved are described. The ideal plastic for the job is resistant to chemicals at high and low temperatures, flexible, has good adhesion, abrasion resistance, impact resistance, and a smooth glossy finish. The phenol aldehyde and epoxy resins presently offered by the industry fulfill these specifications very well; the multicoating and multibaking techniques improve their performance. Due to wide variations in the severity of the paraffin problem from one oil field to another, there is no general rule to estimate the possible savings from using plastic-coated sucker rods. The process, however, does appear to do a remarkable job in controlling paraffin buildup wherever it is a problem in producing oil by pump.

  19. Plastics: Friend or foe?

    Directory of Open Access Journals (Sweden)

    O P Gupta

    2018-01-01

    Full Text Available Plastics has been playing a very significant role in our life. Being light weight, inexpensive and heving good insulating properties it is being used in all aspects of life, from clothes to contact lenses and from mobile phones to automobiles as well as in medical equipments, However it is not biodegradable, and while degrading to fragments it gets converted in to microplastics and nanoplastics The plastic waste is being recognized as an environmental hazard, since these micr- and nanoplastics find way from landfills to water and foods, It is said that we are not only using, but we are eating, drinking and even braething the plastics. These microplastics in body release certain hazardous chemicals and found to be disrupting functions of certain endocrine organs. Whether the rising prevalence of Diabetes, thyroid disorders or infirtility etc., are realated to the plastics?

  20. Motor cortical plasticity in Parkinson's disease.

    Science.gov (United States)

    Udupa, Kaviraja; Chen, Robert

    2013-09-04

    In Parkinson's disease (PD), there are alterations of the basal ganglia (BG) thalamocortical networks, primarily due to degeneration of nigrostriatal dopaminergic neurons. These changes in subcortical networks lead to plastic changes in primary motor cortex (M1), which mediates cortical motor output and is a potential target for treatment of PD. Studies investigating the motor cortical plasticity using non-invasive transcranial magnetic stimulation (TMS) have found altered plasticity in PD, but there are inconsistencies among these studies. This is likely because plasticity depends on many factors such as the extent of dopaminergic loss and disease severity, response to dopaminergic replacement therapies, development of l-DOPA-induced dyskinesias (LID), the plasticity protocol used, medication, and stimulation status in patients treated with deep brain stimulation (DBS). The influences of LID and DBS on BG and M1 plasticity have been explored in animal models and in PD patients. In addition, many other factors such age, genetic factors (e.g., brain derived neurotropic factor and other neurotransmitters or receptors polymorphism), emotional state, time of the day, physical fitness have been documented to play role in the extent of plasticity induced by TMS in human studies. In this review, we summarize the studies that investigated M1 plasticity in PD and demonstrate how these afore-mentioned factors affect motor cortical plasticity in PD. We conclude that it is important to consider the clinical, demographic, and technical factors that influence various plasticity protocols while developing these protocols as diagnostic or prognostic tools in PD. We also discuss how the modulation of cortical excitability and the plasticity with these non-invasive brain stimulation techniques facilitate the understanding of the pathophysiology of PD and help design potential therapeutic possibilities in this disorder.

  1. Process for remediation of plastic waste

    Science.gov (United States)

    Pol, Vilas G [Westmont, IL; Thiyagarajan, Pappannan [Germantown, MD

    2012-04-10

    A single step process for degrading plastic waste by converting the plastic waste into carbonaceous products via thermal decomposition of the plastic waste by placing the plastic waste into a reactor, heating the plastic waste under an inert or air atmosphere until the temperature of 700.degree. C. is achieved, allowing the reactor to cool down, and recovering the resulting decomposition products therefrom. The decomposition products that this process yields are carbonaceous materials, and more specifically egg-shaped and spherical-shaped solid carbons. Additionally, in the presence of a transition metal compound, this thermal decomposition process produces multi-walled carbon nanotubes.

  2. Soft computing in artificial intelligence

    CERN Document Server

    Matson, Eric

    2014-01-01

    This book explores the concept of artificial intelligence based on knowledge-based algorithms. Given the current hardware and software technologies and artificial intelligence theories, we can think of how efficient to provide a solution, how best to implement a model and how successful to achieve it. This edition provides readers with the most recent progress and novel solutions in artificial intelligence. This book aims at presenting the research results and solutions of applications in relevance with artificial intelligence technologies. We propose to researchers and practitioners some methods to advance the intelligent systems and apply artificial intelligence to specific or general purpose. This book consists of 13 contributions that feature fuzzy (r, s)-minimal pre- and β-open sets, handling big coocurrence matrices, Xie-Beni-type fuzzy cluster validation, fuzzy c-regression models, combination of genetic algorithm and ant colony optimization, building expert system, fuzzy logic and neural network, ind...

  3. Common genetic variants near the Brittle Cornea Syndrome locus ZNF469 influence the blinding disease risk factor central corneal thickness.

    Directory of Open Access Journals (Sweden)

    Yi Lu

    2010-05-01

    Full Text Available Central corneal thickness (CCT, one of the most highly heritable human traits (h(2 typically>0.9, is important for the diagnosis of glaucoma and a potential risk factor for glaucoma susceptibility. We conducted genome-wide association studies in five cohorts from Australia and the United Kingdom (total N = 5058. Three cohorts were based on individually genotyped twin collections, with the remaining two cohorts genotyped on pooled samples from singletons with extreme trait values. The pooled sample findings were validated by individual genotyping the pooled samples together with additional samples also within extreme quantiles. We describe methods for efficient combined analysis of the results from these different study designs. We have identified and replicated quantitative trait loci on chromosomes 13 and 16 for association with CCT. The locus on chromosome 13 (nearest gene FOXO1 had an overall meta-analysis p-value for all the individually genotyped samples of 4.6x10(-10. The locus on chromosome 16 was associated with CCT with p = 8.95x10(-11. The nearest gene to the associated chromosome 16 SNPs was ZNF469, a locus recently implicated in Brittle Cornea Syndrome (BCS, a very rare disorder characterized by abnormal thin corneas. Our findings suggest that in addition to rare variants in ZNF469 underlying CCT variation in BCS patients, more common variants near this gene may contribute to CCT variation in the general population.

  4. DELAMINATION PREDICTION IN DRILLING OF CFRP COMPOSITES USING ARTIFICIAL NEURAL NETWORK

    Directory of Open Access Journals (Sweden)

    K. PALANIKUMAR

    2011-04-01

    Full Text Available Carbon fibre reinforced plastic (CFRP materials play a major role in the applications of aeronautic, aerospace, sporting and transportation industries. Machining is indispensible and hence drilling of CFRP materials is considered in this present study with respect to spindle speed in rpm, drill size in mm and feed in mm/min. Delamination is one of the major defects to be dealt with. The experiments are carried out using computer numerical control machine and the results are applied to an artificial neural network (ANN for the prediction of delamination factor at the exit plane of the CFRP material. It is found that ANN model predicts the delamination for any given set of machining parameters with a maximum error of 0.81% and a minimum error of 0.03%. Thus an ANN model is highly suitable for the prediction of delamination in CFRP materials.

  5. DESIGNERS’ KNOWLEDGE IN PLASTICS

    DEFF Research Database (Denmark)

    Eriksen, Kaare

    2013-01-01

    The Industrial designers’ knowledge in plastics materials and manufacturing principles of polymer products is very important for the innovative strength of the industry, according to a group of Danish plastics manufacturers, design students and practicing industrial designers. These three groups ...

  6. Transfer of mesenchymal stem cells and cyclosporine A on alkali-injured rabbit cornea using nanofiber scaffolds strongly reduces corneal neovascularization and scar formation

    Czech Academy of Sciences Publication Activity Database

    Čejka, Čestmír; Čejková, Jitka; Trošan, Peter; Zajícová, Alena; Syková, Eva; Holáň, Vladimír

    2016-01-01

    Roč. 31, č. 9 (2016), s. 969-980 ISSN 0213-3911 R&D Projects: GA MZd NT14102; GA ČR(CZ) GA14-12580S; GA MŠk(CZ) LO1309; GA MŠk(CZ) ED1.1.00/02.0109 Institutional support: RVO:68378041 Keywords : alkali * cornea * CsA nanofibers * MSCs nanofibers * MSCs-CsA nanofibers Subject RIV: FF - HEENT, Dentistry Impact factor: 2.025, year: 2016

  7. The use of Wavelight® Contoura to create a uniform cornea: the LYRA protocol. Part 3: the results of 50 treated eyes

    OpenAIRE

    Motwani M

    2017-01-01

    Manoj Motwani Motwani LASIK Institute, San Diego, CA, USA Purpose: To demonstrate how using the Wavelight Contoura measured astigmatism and axis eliminates corneal astigmatism and creates uniformly shaped corneas. Patients and methods: A retrospective analysis was conducted of the first 50 eyes to have bilateral full WaveLight® Contoura LASIK correction of measured astigmatism and axis (vs conventional manifest refraction), using the Layer Yolked Reduction of Astigmatism Protocol in...

  8. Artificial Intelligence

    CERN Document Server

    Warwick, Kevin

    2011-01-01

    if AI is outside your field, or you know something of the subject and would like to know more then Artificial Intelligence: The Basics is a brilliant primer.' - Nick Smith, Engineering and Technology Magazine November 2011 Artificial Intelligence: The Basics is a concise and cutting-edge introduction to the fast moving world of AI. The author Kevin Warwick, a pioneer in the field, examines issues of what it means to be man or machine and looks at advances in robotics which have blurred the boundaries. Topics covered include: how intelligence can be defined whether machines can 'think' sensory

  9. Charlas sobre inteligencia artificial

    OpenAIRE

    Álvarez Sánchez, José Ramón; Ferrández Vicente, José Manuel; Paz López, Félix de la

    2014-01-01

    Serie: Informática en Radio 3 La Inteligencia Artificial es una de las ciencias que causa mayor impacto en la sociedad, mucho más si tenemos en cuenta que cambiará el futuro de la humanidad. En España existen actualmente un nutrido grupo de equipos de investigación relacionados con las tecnologías de computación natural-artificial que aúnan sus esfuerzos a través de la RTNAC la Red Temática en Tecnologías de Computación Natural-Artificial . La UNED participa en todas sus actividades desde ...

  10. Artificial Intelligence Project

    Science.gov (United States)

    1990-01-01

    Symposium on Aritificial Intelligence and Software Engineering Working Notes, March 1989. Blumenthal, Brad, "An Architecture for Automating...Artificial Intelligence Project Final Technical Report ARO Contract: DAAG29-84-K-OGO Artificial Intelligence LaboratO"ry The University of Texas at...Austin N>.. ~ ~ JA 1/I 1991 n~~~ Austin, Texas 78712 ________k A,.tificial Intelligence Project i Final Technical Report ARO Contract: DAAG29-84-K-0060

  11. Grain Interactions in Crystal Plasticity

    International Nuclear Information System (INIS)

    Boyle, K.P.; Curtin, W.A.

    2005-01-01

    The plastic response of a sheet metal is governed by the collective response of the underlying grains. Intragranular plasticity depends on intrinsic variables such as crystallographic orientation and on extrinsic variables such as grain interactions; however, the role of the latter is not well understood. A finite element crystal plasticity formulation is used to investigate the importance of grain interactions on intragranular plastic deformation in initially untextured polycrystalline aggregates. A statistical analysis reveals that grain interactions are of equal (or more) importance for determining the average intragranular deviations from the applied strain as compared to the orientation of the grain itself. Furthermore, the influence of the surrounding grains is found to extend past nearest neighbor interactions. It is concluded that the stochastic nature of the mesoscale environment must be considered for a proper understanding of the plastic response of sheet metals at the grain-scale

  12. Degradation of oxo-biodegradable plastic by Pleurotus ostreatus.

    Science.gov (United States)

    da Luz, José Maria Rodrigues; Paes, Sirlaine Albino; Nunes, Mateus Dias; da Silva, Marliane de Cássia Soares; Kasuya, Maria Catarina Megumi

    2013-01-01

    Growing concerns regarding the impact of the accumulation of plastic waste over several decades on the environmental have led to the development of biodegradable plastic. These plastics can be degraded by microorganisms and absorbed by the environment and are therefore gaining public support as a possible alternative to petroleum-derived plastics. Among the developed biodegradable plastics, oxo-biodegradable polymers have been used to produce plastic bags. Exposure of this waste plastic to ultraviolet light (UV) or heat can lead to breakage of the polymer chains in the plastic, and the resulting compounds are easily degraded by microorganisms. However, few studies have characterized the microbial degradation of oxo-biodegradable plastics. In this study, we tested the capability of Pleurotus ostreatus to degrade oxo-biodegradable (D2W) plastic without prior physical treatment, such as exposure to UV or thermal heating. After 45 d of incubation in substrate-containing plastic bags, the oxo-biodegradable plastic, which is commonly used in supermarkets, developed cracks and small holes in the plastic surface as a result of the formation of hydroxyl groups and carbon-oxygen bonds. These alterations may be due to laccase activity. Furthermore, we observed the degradation of the dye found in these bags as well as mushroom formation. Thus, P. ostreatus degrades oxo-biodegradable plastics and produces mushrooms using this plastic as substrate.

  13. Degradation of oxo-biodegradable plastic by Pleurotus ostreatus.

    Directory of Open Access Journals (Sweden)

    José Maria Rodrigues da Luz

    Full Text Available Growing concerns regarding the impact of the accumulation of plastic waste over several decades on the environmental have led to the development of biodegradable plastic. These plastics can be degraded by microorganisms and absorbed by the environment and are therefore gaining public support as a possible alternative to petroleum-derived plastics. Among the developed biodegradable plastics, oxo-biodegradable polymers have been used to produce plastic bags. Exposure of this waste plastic to ultraviolet light (UV or heat can lead to breakage of the polymer chains in the plastic, and the resulting compounds are easily degraded by microorganisms. However, few studies have characterized the microbial degradation of oxo-biodegradable plastics. In this study, we tested the capability of Pleurotus ostreatus to degrade oxo-biodegradable (D2W plastic without prior physical treatment, such as exposure to UV or thermal heating. After 45 d of incubation in substrate-containing plastic bags, the oxo-biodegradable plastic, which is commonly used in supermarkets, developed cracks and small holes in the plastic surface as a result of the formation of hydroxyl groups and carbon-oxygen bonds. These alterations may be due to laccase activity. Furthermore, we observed the degradation of the dye found in these bags as well as mushroom formation. Thus, P. ostreatus degrades oxo-biodegradable plastics and produces mushrooms using this plastic as substrate.

  14. Degradation of Oxo-Biodegradable Plastic by Pleurotus ostreatus

    Science.gov (United States)

    da Luz, José Maria Rodrigues; Paes, Sirlaine Albino; Nunes, Mateus Dias; da Silva, Marliane de Cássia Soares; Kasuya, Maria Catarina Megumi

    2013-01-01

    Growing concerns regarding the impact of the accumulation of plastic waste over several decades on the environmental have led to the development of biodegradable plastic. These plastics can be degraded by microorganisms and absorbed by the environment and are therefore gaining public support as a possible alternative to petroleum-derived plastics. Among the developed biodegradable plastics, oxo-biodegradable polymers have been used to produce plastic bags. Exposure of this waste plastic to ultraviolet light (UV) or heat can lead to breakage of the polymer chains in the plastic, and the resulting compounds are easily degraded by microorganisms. However, few studies have characterized the microbial degradation of oxo-biodegradable plastics. In this study, we tested the capability of Pleurotus ostreatus to degrade oxo-biodegradable (D2W) plastic without prior physical treatment, such as exposure to UV or thermal heating. After 45 d of incubation in substrate-containing plastic bags, the oxo-biodegradable plastic, which is commonly used in supermarkets, developed cracks and small holes in the plastic surface as a result of the formation of hydroxyl groups and carbon-oxygen bonds. These alterations may be due to laccase activity. Furthermore, we observed the degradation of the dye found in these bags as well as mushroom formation. Thus, P. ostreatus degrades oxo-biodegradable plastics and produces mushrooms using this plastic as substrate. PMID:23967057

  15. Desorption modeling of hydrophobic organic chemicals from plastic sheets using experimentally determined diffusion coefficients in plastics.

    Science.gov (United States)

    Lee, Hwang; Byun, Da-Eun; Kim, Ju Min; Kwon, Jung-Hwan

    2018-01-01

    To evaluate rate of migration from plastic debris, desorption of model hydrophobic organic chemicals (HOCs) from polyethylene (PE)/polypropylene (PP) films to water was measured using PE/PP films homogeneously loaded with the HOCs. The HOCs fractions remaining in the PE/PP films were compared with those predicted using a model characterized by the mass transfer Biot number. The experimental data agreed with the model simulation, indicating that HOCs desorption from plastic particles can generally be described by the model. For hexachlorocyclohexanes with lower plastic-water partition coefficients, desorption was dominated by diffusion in the plastic film, whereas desorption of chlorinated benzenes with higher partition coefficients was determined by diffusion in the aqueous boundary layer. Evaluation of the fraction of HOCs remaining in plastic films with respect to film thickness and desorption time showed that the partition coefficient between plastic and water is the most important parameter influencing the desorption half-life. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Rearing the southern green stink bug using an artificial dry diet and an artificial plant Criação do percevejo-verde usando dieta artificial seca e planta artificial

    Directory of Open Access Journals (Sweden)

    ANTÔNIO RICARDO PANIZZI

    2000-09-01

    Full Text Available Laboratory and greenhouse studies were conducted with an artificial dry diet to rear nymphs, and with an artificial plant as substrate for egg laying by the southern green stink bug, Nezara viridula (L.. The artificial diet was composed of: soybean protein (15 g; potato starch (7.5 g; dextrose (7.5 g; sucrose (2.5 g; cellulose (12.5 g; vitamin mixture (niacinamide 1 g, calcium pantothenate 1 g, thiamine 0.25 g, riboflavin 0.5 g, pyridoxine 0.25 g, folic acid 0.25 g, biotin 0.02 mL, vitamin B12 1 g - added to 1,000 mL of distilled water (5.0 mL; soybean oil (20 mL; wheat germ (17.9 g; and water (30 mL. Nymphs showed normal feeding behavior when fed on the artificial diet. Nymphal development time was longer than or similar to that of nymphs fed on soybean pods. Total nymphal mortality was low (ca. 30%, both for nymphs reared on the artificial diet, and for nymphs fed on soybean pods. At adult emergence, fresh body weights were significantly (PForam conduzidos estudos em laboratório e em casa de vegetação, com uma dieta artificial seca para a criação de ninfas e com um modelo de planta artificial como substrato para a colocação de ovos por adultos do percevejo-verde, Nezara viridula (L.. Os componentes da dieta artificial foram: proteína de soja (15 g; fécula de batata (7,5 g; dextrose (7,5 g; sacarose (2,5 g; celulose (12,5 g; mistura vitamínica (niacinamida 1 g, pantotenato de cálcio 1 g, tiamina 0,25 g, riboflavina 0,5 g, piridoxina 0,25 g, ácido fólico 0,25 g, biotina 0,02 mL, vitamina B12 1 g, adicionada em 1.000 mL de água destilada (5,0 mL; óleo de soja (20 mL; germe de trigo (17,9 g; e água (30 mL. As ninfas alimentaram-se normalmente da dieta, embora o tempo de desenvolvimento tenha sido em um caso, maior, e em outro, semelhante, ao das ninfas que se alimentaram de vagens da soja. A mortalidade total das ninfas foi baixa (ca. 30%, tanto na dieta como na vagem de soja. Na emergência, os adultos apresentaram peso fresco

  17. Robust and Accurate Closed-Loop Control of McKibben Artificial Muscle Contraction with a Linear Single Integral Action

    Directory of Open Access Journals (Sweden)

    Bertrand Tondu

    2014-06-01

    Full Text Available We analyze the possibility of taking advantage of artificial muscle’s own stiffness and damping, and substituting it for a classic proportional-integral-derivative controller (PID controller an I controller. The advantages are that there would only be one parameter to tune and no need for a dynamic model. A stability analysis is proposed from a simple phenomenological artificial muscle model. Step and sinus-wave tracking responses performed with pneumatic McKibben muscles are reported showing the practical efficiency of the method to combine accuracy and load robustness. In the particular case of the McKibben artificial muscle technology, we suggest that the dynamic performances in stability and load robustness would result from the textile nature of its braided sleeve and its internal friction which do not obey Coulomb’s third law, as verified by preliminary reported original friction experiments. Comparisons are reported between three kinds of braided sleeves made of rayon yarns, plastic, and thin metal wires, whose similar closed-loop dynamic performances are highlighted. It is also experimentally shown that a sleeve braided with thin metal wires can give high accuracy performance, in step as in tracking response. This would be due to a low static friction coefficient combined with a kinetic friction exponentially increasing with speed in accordance with hydrodynamic lubrication theory applied to textile physics.

  18. Liquid crystal displays with plastic substrates

    Science.gov (United States)

    Lueder, Ernst H.

    1998-04-01

    Plastic substrates for the cells of displays exhibit only 1/6 of the weight of glass substrates; they are virtually unbreakable; their flexibility allows the designer to give them a shape suppressing reflections, to realize a display board on a curved surface or meeting the requirements for an appealing styling; displays with plastics are thinner which provides a wider viewing angle. These features render them attractive for displays in portable systems such as mobile phones, pagers, smart cards, personal digital assistants (PDAs) and portable computers. Reflective displays are especially attractive as they don't need a back light. The most important requirements are the protection of plastics against gas permeation and chemical agents, the prevention of layers on plastics to crack or peel off when the plastic is bent and the development of low temperature thin film processes because the plastics, as a rule, only tolerate temperatures below 150 degrees Celsius. Bistable reflective FLC- and PSCT-displays with plastic substrates will be introduced. Special sputtered SiO2-orientation layers preserve the displayed information even if pressure or torsion is applied. MIM-addressed PDLC-displays require additional Al- or Ti-layers which provide the necessary ductility. Sputtered or PECVD-generated TFTs can be fabricated on plastics at temperatures below 150 degrees Celsius.

  19. Beyond AI: Artificial Dreams Conference

    CERN Document Server

    Zackova, Eva; Kelemen, Jozef; Beyond Artificial Intelligence : The Disappearing Human-Machine Divide

    2015-01-01

    This book is an edited collection of chapters based on the papers presented at the conference “Beyond AI: Artificial Dreams” held in Pilsen in November 2012. The aim of the conference was to question deep-rooted ideas of artificial intelligence and cast critical reflection on methods standing at its foundations.  Artificial Dreams epitomize our controversial quest for non-biological intelligence, and therefore the contributors of this book tried to fully exploit such a controversy in their respective chapters, which resulted in an interdisciplinary dialogue between experts from engineering, natural sciences and humanities.   While pursuing the Artificial Dreams, it has become clear that it is still more and more difficult to draw a clear divide between human and machine. And therefore this book tries to portrait such an image of what lies beyond artificial intelligence: we can see the disappearing human-machine divide, a very important phenomenon of nowadays technological society, the phenomenon which i...

  20. Artificial Photosynthesis: Beyond Mimicking Nature

    International Nuclear Information System (INIS)

    Dau, Holger; Fujita, Etsuko; Sun, Licheng

    2017-01-01

    In this Editorial, Guest Editors Holger Dau, Etsuko Fujita, and Licheng Sun introduce the Special Issue of ChemSusChem on “Artificial Photosynthesis for Sustainable Fuels”. Here, they discuss the need for non-fossil based fuels, introduce both biological and artificial photosynthesis, and outline various important concepts in artificial photosynthesis, including molecular and solid-state catalysts for water oxidation and hydrogen evolution, catalytic CO 2 reduction, and photoelectrochemical systems.