WorldWideScience

Sample records for plasma sources science

  1. Capillary plasma jet: A low volume plasma source for life science applications

    Energy Technology Data Exchange (ETDEWEB)

    Topala, I., E-mail: ionut.topala@uaic.ro, E-mail: tmnagat@ipc.shizuoka.ac.jp [Alexandru Ioan Cuza University of Iasi, Faculty of Physics, Iasi Plasma Advanced Research Center (IPARC), Bd. Carol I No. 11, Iasi 700506 (Romania); Nagatsu, M., E-mail: ionut.topala@uaic.ro, E-mail: tmnagat@ipc.shizuoka.ac.jp [Graduate School of Science and Technology, Shizuoka University, 3-5-1 Johoku, Naka-ku, Hamamatsu 432-8561 (Japan)

    2015-02-02

    In this letter, we present results from multispectroscopic analysis of protein films, after exposure to a peculiar plasma source, i.e., the capillary plasma jet. This plasma source is able to generate very small pulsed plasma volumes, in kilohertz range, with characteristic dimensions smaller than 1 mm. This leads to specific microscale generation and transport of all plasma species. Plasma diagnosis was realized using general electrical and optical methods. Depending on power level and exposure duration, this miniature plasma jet can induce controllable modifications to soft matter targets. Detailed discussions on protein film oxidation and chemical etching are supported by results from absorption, X-ray photoelectron spectroscopy, and microscopy techniques. Further exploitation of principles presented here may consolidate research interests involving plasmas in biotechnologies and plasma medicine, especially in patterning technologies, modified biomolecule arrays, and local chemical functionalization.

  2. Plasma Science Committee (PLSC)

    Science.gov (United States)

    1990-12-01

    The Plasma Science Committee (PLSC) is a standing committee under the auspices of the Board on Physics and Astronomy, Commission on Physical Sciences, Mathematics, and Applications of the National Academy of Sciences - National Research Council. Plasma sciences represent a broad and diverse field. The PLSC has accepted the responsibility of monitoring the continuing development and assessing the general health of the field as whole. Although select advisory bodies have been created to address specific issues that affect plasma science, such as the Fusion Policy Advisory Committee (FPAC), the PLSC provides a focus for the plasma science community that is unique and essential. The membership of the PLSC is drawn from research laboratories in universities, industry, and government. Areas of expertise on the committee include accelerators and beams, space physics, astrophysics, computational physics and applied mathematics, fusion plasmas, fundamental experiments and theory, radiation sources, low temperature plasmas, and plasma-surface interactions. The PLSC is well prepared to respond to requests for studies on specific issues.

  3. Pulsed Plasma Electron Sources

    Science.gov (United States)

    Krasik, Yakov

    2008-11-01

    Pulsed (˜10-7 s) electron beams with high current density (>10^2 A/cm^2) are generated in diodes with electric field of E > 10^6 V/cm. The source of electrons in these diodes is explosive emission plasma, which limits pulse duration; in the case E Hadas and Ya. E. Krasik, Europhysics Lett. 82, 55001 (2008).

  4. Large area plasma source

    Science.gov (United States)

    Foster, John (Inventor); Patterson, Michael (Inventor)

    2008-01-01

    An all permanent magnet Electron Cyclotron Resonance, large diameter (e.g., 40 cm) plasma source suitable for ion/plasma processing or electric propulsion, is capable of producing uniform ion current densities at its exit plane at very low power (e.g., below 200 W), and is electrodeless to avoid sputtering or contamination issues. Microwave input power is efficiently coupled with an ionizing gas without using a dielectric microwave window and without developing a throat plasma by providing a ferromagnetic cylindrical chamber wall with a conical end narrowing to an axial entrance hole for microwaves supplied on-axis from an open-ended waveguide. Permanent magnet rings are attached inside the wall with alternating polarities against the wall. An entrance magnet ring surrounding the entrance hole has a ferromagnetic pole piece that extends into the chamber from the entrance hole to a continuing second face that extends radially across an inner pole of the entrance magnet ring.

  5. Plasma Sources for Medical Applications - A Comparison of Spot Like Plasmas and Large Area Plasmas

    Science.gov (United States)

    Weltmann, Klaus-Dieter

    2015-09-01

    Plasma applications in life science are currently emerging worldwide. Whereas today's commercially available plasma surgical technologies such as argon plasma coagulation (APC) or ablation are mainly based on lethal plasma effects on living systems, the newly emerging therapeutic applications will be based on selective, at least partially non-lethal, possibly stimulating plasma effects on living cells and tissue. Promising results could be obtained by different research groups worldwide revealing a huge potential for the application of low temperature atmospheric pressure plasma in fields such as tissue engineering, healing of chronic wounds, treatment of skin diseases, tumor treatment based on specific induction of apoptotic processes, inhibition of biofilm formation and direct action on biofilms or treatment of dental diseases. The development of suitable and reliable plasma sources for the different therapies requires an in-depth knowledge of their physics, chemistry and parameters. Therefore much basic research still needs to be conducted to minimize risk and to provide a scientific fundament for new plasma-based medical therapies. It is essential to perform a comprehensive assessment of physical and biological experiments to clarify minimum standards for plasma sources for applications in life science and for comparison of different sources. One result is the DIN-SPEC 91315, which is now open for further improvements. This contribution intends to give an overview on the status of commercial cold plasma sources as well as cold plasma sources still under development for medical use. It will discuss needs, prospects and approaches for the characterization of plasmas from different points of view. Regarding the manageability in everyday medical life, atmospheric pressure plasma jets (APPJ) and dielectric barrier discharges (DBD) are of special interest. A comprehensive risk-benefit assessment including the state of the art of commercial sources for medical use

  6. 21 CFR 640.60 - Source Plasma.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Source Plasma. 640.60 Section 640.60 Food and... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.60 Source Plasma. The proper name of the product shall be Source Plasma. The product is defined as the fluid portion of human blood...

  7. Miniaturized cathodic arc plasma source

    Science.gov (United States)

    Anders, Andre; MacGill, Robert A.

    2003-04-15

    A cathodic arc plasma source has an anode formed of a plurality of spaced baffles which extend beyond the active cathode surface of the cathode. With the open baffle structure of the anode, most macroparticles pass through the gaps between the baffles and reflect off the baffles out of the plasma stream that enters a filter. Thus the anode not only has an electrical function but serves as a prefilter. The cathode has a small diameter, e.g. a rod of about 1/4 inch (6.25 mm) diameter. Thus the plasma source output is well localized, even with cathode spot movement which is limited in area, so that it effectively couples into a miniaturized filter. With a small area cathode, the material eroded from the cathode needs to be replaced to maintain plasma production. Therefore, the source includes a cathode advancement or feed mechanism coupled to cathode rod. The cathode also requires a cooling mechanism. The movable cathode rod is housed in a cooled metal shield or tube which serves as both a current conductor, thus reducing ohmic heat produced in the cathode, and as the heat sink for heat generated at or near the cathode. Cooling of the cathode housing tube is done by contact with coolant at a place remote from the active cathode surface. The source is operated in pulsed mode at relatively high currents, about 1 kA. The high arc current can also be used to operate the magnetic filter. A cathodic arc plasma deposition system using this source can be used for the deposition of ultrathin amorphous hard carbon (a-C) films for the magnetic storage industry.

  8. Burning plasmas in ITER for energy source

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Nobuyuki [Atomic Energy Commission, Tokyo (Japan)

    2002-10-01

    Fusion research and development has two aspects. One is an academic research on science and technology, i.e., discovery and understanding of unexpected phenomena and, development of innovative technology, respectively. The other is energy source development to realize fusion as a viable energy future. Fusion research has been made remarkable progress in the past several decades, and ITER will soon realize burning plasma that is essential for both academic research and energy development. With ITER, scientific research on unknown phenomena such as self-organization of the plasma in burning state will become possible and it contributes to create a variety of academic outcome. Fusion researchers will have a responsibility to generate actual energy, and electricity generation immediately after the success of burning plasma control experiment in ITER is the next important step that has to be discussed seriously. (author)

  9. The HelCat dual-source plasma device.

    Science.gov (United States)

    Lynn, Alan G; Gilmore, Mark; Watts, Christopher; Herrea, Janis; Kelly, Ralph; Will, Steve; Xie, Shuangwei; Yan, Lincan; Zhang, Yue

    2009-10-01

    The HelCat (Helicon-Cathode) device has been constructed to support a broad range of basic plasma science experiments relevant to the areas of solar physics, laboratory astrophysics, plasma nonlinear dynamics, and turbulence. These research topics require a relatively large plasma source capable of operating over a broad region of parameter space with a plasma duration up to at least several milliseconds. To achieve these parameters a novel dual-source system was developed utilizing both helicon and thermionic cathode sources. Plasma parameters of n(e) approximately 0.5-50 x 10(18) m(-3) and T(e) approximately 3-12 eV allow access to a wide range of collisionalities important to the research. The HelCat device and initial characterization of plasma behavior during dual-source operation are described.

  10. The 2017 Plasma Roadmap: Low temperature plasma science and technology

    Science.gov (United States)

    Journal of Physics D: Applied Physics published the first Plasma Roadmap in 2012 consisting of the individual perspectives of 16 leading experts in the various sub-fields of low temperature plasma science and technology. The 2017 Plasma Roadmap is the first update of a planned series of periodic upd...

  11. Some plasma aspects and plasma diagnostics of ion sources.

    Science.gov (United States)

    Wiesemann, Klaus

    2008-02-01

    We consider plasma properties in the most advanced type of plasma ion sources, electron cyclotron resonance ion sources for highly charged ions. Depending on the operation conditions the plasma in these sources may be highly ionized, which completely changes its transport properties. The most striking difference to weakly ionized plasma is that diffusion will become intrinsically ambipolar. We further discuss means of plasma diagnostics. As noninvasive diagnostic methods we will discuss analysis of the ion beam, optical spectroscopy, and measurement of the x-ray bremsstrahlung continuum. From beam analysis and optical spectroscopy one may deduce ion densities, and electron densities and distribution functions as a mean over the line of sight along the axis (optical spectroscopy) or at the plasma edge (ion beam). From x-ray spectra one obtains information about the population of highly energetic electrons and the energy transfer from the driving electromagnetic waves to the plasma -- basic data for plasma modeling.

  12. Physical investigation of a quad confinement plasma source

    Science.gov (United States)

    Knoll, Aaron; Lucca Fabris, Andrea; Young, Christopher; Cappelli, Mark

    2016-10-01

    Quad magnetic confinement plasma sources are novel magnetized DC discharges suitable for applications in a broad range of fields, particularly space propulsion, plasma etching and deposition. These sources contain a square discharge channel with magnetic cusps at the four lateral walls, enhancing plasma confinement and electron residence time inside the device. The magnetic field topology is manipulated using four independent electromagnets on each edge of the channel, tuning the properties of the generated plasma. We characterize the plasma ejected from the quad confinement sources using a combination of traditional electrostatic probes and non-intrusive laser-based diagnostics. Measurements show a strong ion acceleration layer located 8 cm downstream of the exit plane, beyond the extent of the magnetic field. The ion velocity field is investigated with different magnetic configurations, demonstrating how ion trajectories may be manipulated. C.Y. acknowledges support from the DOE NSSA Stewardship Science Graduate Fellowship under contract DE-FC52-08NA28752.

  13. Plasma Cathode Electron Sources Physics, Technology, Applications

    CERN Document Server

    Oks, Efim

    2006-01-01

    This book fills the gap for a textbook describing this kind of electron beam source in a systematic and thorough manner: from physical processes of electron emission to examples of real plasma electron sources and their applications.

  14. The study of helicon plasma source.

    Science.gov (United States)

    Miao, Ting-Ting; Zhao, Hong-Wei; Liu, Zhan-Wen; Shang, Yong; Sun, Liang-Ting; Zhang, Xue-Zhen; Zhao, Huan-Yu

    2010-02-01

    Helicon plasma source is known as efficient generator of uniform and high density plasma. A helicon plasma source was developed for investigation of plasma neutralization and plasma lens in the Institute of Modern Physics in China. In this paper, the characteristics of helicon plasma have been studied by using Langmuir four-probe and a high argon plasma density up to 3.9x10(13) cm(-3) have been achieved with the Nagoya type III antenna at the conditions of the magnetic intensity of 200 G, working gas pressure of 2.8x10(-3) Pa, and rf power of 1200 W with a frequency of 27.12 MHz. In the experiment, the important phenomena have been found: for a given magnetic induction intensity, the plasma density became greater with the increase in rf power and tended to saturation, and the helicon mode appeared at the rf power between 200 and 400 W.

  15. Surface plasma source with saddle antenna radio frequency plasma generator.

    Science.gov (United States)

    Dudnikov, V; Johnson, R P; Murray, S; Pennisi, T; Piller, C; Santana, M; Stockli, M; Welton, R

    2012-02-01

    A prototype RF H(-) surface plasma source (SPS) with saddle (SA) RF antenna is developed which will provide better power efficiency for high pulsed and average current, higher brightness with longer lifetime and higher reliability. Several versions of new plasma generators with small AlN discharge chambers and different antennas and magnetic field configurations were tested in the plasma source test stand. A prototype SA SPS was installed in the Spallation Neutron Source (SNS) ion source test stand with a larger, normal-sized SNS AlN chamber that achieved unanalyzed peak currents of up to 67 mA with an apparent efficiency up to 1.6 mA∕kW. Control experiments with H(-) beam produced by SNS SPS with internal and external antennas were conducted. A new version of the RF triggering plasma gun has been designed. A saddle antenna SPS with water cooling is fabricated for high duty factor testing.

  16. Saturn Plasma Sources and Associated Transport Processes

    Science.gov (United States)

    Blanc, M.; Andrews, D. J.; Coates, A. J.; Hamilton, D. C.; Jackman, C. M.; Jia, X.; Kotova, A.; Morooka, M.; Smith, H. T.; Westlake, J. H.

    2015-10-01

    This article reviews the different sources of plasma for Saturn's magnetosphere, as they are known essentially from the scientific results of the Cassini-Huygens mission to Saturn and Titan. At low and medium energies, the main plasma source is the H2O cloud produced by the "geyser" activity of the small satellite Enceladus. Impact ionization of this cloud occurs to produce on the order of 100 kg/s of fresh plasma, a source which dominates all the other ones: Titan (which produces much less plasma than anticipated before the Cassini mission), the rings, the solar wind (a poorly known source due to the lack of quantitative knowledge of the degree of coupling between the solar wind and Saturn's magnetosphere), and the ionosphere. At higher energies, energetic particles are produced by energy diffusion and acceleration of lower energy plasma produced by the interchange instabilities induced by the rapid rotation of Saturn, and possibly, for the highest energy range, by contributions from the CRAND process acting inside Saturn's magnetosphere. Discussion of the transport and acceleration processes acting on these plasma sources shows the importance of rotation-induced radial transport and energization of the plasma, and also shows how much the unexpected planetary modulation of essentially all plasma parameters of Saturn's magnetosphere remains an unexplained mystery.

  17. The HelCat basic plasma science device

    Science.gov (United States)

    Gilmore, M.; Lynn, A. G.; Desjardins, T. R.; Zhang, Y.; Watts, C.; Hsu, S. C.; Betts, S.; Kelly, R.; Schamiloglu, E.

    2015-01-01

    The Helicon-Cathode(HelCat) device is a medium-size linear experiment suitable for a wide range of basic plasma science experiments in areas such as electrostatic turbulence and transport, magnetic relaxation, and high power microwave (HPM)-plasma interactions. The HelCat device is based on dual plasma sources located at opposite ends of the 4 m long vacuum chamber - an RF helicon source at one end and a thermionic cathode at the other. Thirteen coils provide an axial magnetic field B >= 0.220 T that can be configured individually to give various magnetic configurations (e.g. solenoid, mirror, cusp). Additional plasma sources, such as a compact coaxial plasma gun, are also utilized in some experiments, and can be located either along the chamber for perpendicular (to the background magnetic field) plasma injection, or at one of the ends for parallel injection. Using the multiple plasma sources, a wide range of plasma parameters can be obtained. Here, the HelCat device is described in detail and some examples of results from previous and ongoing experiments are given. Additionally, examples of planned experiments and device modifications are also discussed.

  18. Hollow-Cathode Source Generates Plasma

    Science.gov (United States)

    Deininger, W. D.; Aston, G.; Pless, L. C.

    1989-01-01

    Device generates argon, krypton, or xenon plasma via thermionic emission and electrical discharge within hollow cathode and ejects plasma into surrounding vacuum. Goes from cold start up to full operation in less than 5 s after initial application of power. Exposed to moist air between operations without significant degradation of starting and running characteristics. Plasma generated by electrical discharge in cathode barrel sustained and aided by thermionic emission from emitter tube. Emitter tube does not depend on rare-earth oxides, making it vulnerable to contamination by exposure to atmosphere. Device modified for use as source of plasma in laboratory experiments or industrial processes.

  19. Plasma Science and Applications at the Intel

    Science.gov (United States)

    Berry, Lee

    2006-10-01

    The Coalition for Plasma Science (CPS) has established a plasma prize at the annual Intel International Science and Engineering Fair (ISEF). The 2006 prize was awarded for a project that investigated the correlation of GPS errors with various measures of near-earth plasma activity. The CPS is a broadly-based group of institutions and individuals whose goal is to increase the understanding of plasmas for non-technical audiences. In addition to the ISEF plasma award, CPS activities include maintaining a website, http://www.plasmacoalition.org; developing educational literature; organizing educational luncheon presentations for Members of Congress and their staffs; and responding to questions about plasmas. In addition, the CPS has begun as effort to examine the plasma content of state education standards with the goal of promoting the adoption of standards with appropriate plasma conten; e.g. are there three or four states of matter. The success of this and other activities depend on the voluntary labor of CPS members and associates. Please send an e-mail to the CPS at CPS@plasmacoalition.org for information if you would like to become involved in spreading the good word about plasmas.

  20. Sources of Pressure in Titan's Plasma Environment

    CERN Document Server

    Achilleos, N; Bertucci, C; Guio, P; Romanelli, N; Sergis, N

    2013-01-01

    In order to analyze varying plasma conditions upstream of Titan, we have combined a physical model of Saturn's plasmadisk with a geometrical model of the oscillating current sheet. During modeled oscillation phases where Titan is furthest from the current sheet, the main sources of plasma pressure in the near-Titan space are the magnetic pressure and, for disturbed conditions, the hot plasma pressure. When Titan is at the center of the sheet, the main source is the dynamic pressure associated with Saturn's cold, subcorotating plasma. Total pressure at Titan (dynamic plus thermal plus magnetic) typically increases by a factor of five as the current sheet center is approached. The predicted incident plasma flow direction deviates from the orbital plane of Titan by < 10 deg. These results suggest a correlation between the location of magnetic pressure maxima and the oscillation phase of the plasmasheet.

  1. Study of Coupling between a Plasma Source and Plasma Fluctuations

    Science.gov (United States)

    Berumen, Jorge; Chu, Feng; Hood, Ryan; Mattingly, Sean; Rogers, Anthony; Skiff, Fred

    2014-10-01

    An experimental study on the coupling between a plasma source and plasma fluctuations in a cylindrical, magnetized, singly-ionized Argon inductively-coupled gas discharge plasma that is weakly collisional is presented. Typical plasma conditions are n ~1010 cm-3 Te ~ 3 eV and B ~ 1 kG. Amplitude Modulation (AM) of the inductively-coupled RF plasma source is produced near the fundamental-mode ion-acoustic wave frequency (~1 kHz) to study the effects of the source-wave interaction and plasma production. Density fluctuation measurements are implemented using Laser-Induced Fluorescence techniques and Langmuir probes. We apply coherent detection with respect to the wave frequency to obtain the perturbed ion distribution function associated with the waves. Measurements of fluctuating I-V traces from a Langmuir probe array and antenna current load are also used to show the effects of the interaction. We would like to acknowledge DOE DE-FG02-99ER54543 for their financial support throughout this research.

  2. Meter scale plasma source for plasma wakefield experiments

    Science.gov (United States)

    Vafaei-Najafabadi, N.; Shaw, J. L.; Marsh, K. A.; Joshi, C.; Hogan, M. J.

    2012-12-01

    High accelerating gradients generated by a high density electron beam moving through plasma has been used to double the energy of the SLAC electron beam [1]. During that experiment, the electron current density was high enough to generate its own plasma without significant head erosion. In the newly commissioned FACET facility at SLAC, the peak current will be lower and without pre-ionization, head erosion will be a significant challenge for the planned experiments. In this work we report on our design of a meter scale plasma source for these experiments to effectively avoid the problem of head erosion. The plasma source is based on a homogeneous metal vapor gas column that is generated in a heat pipe oven [2]. A lithium oven over 30 cm long at densities over 1017 cm-3 has been constructed and tested at UCLA. The plasma is then generated by coupling a 10 TW short pulse Ti:Sapphire laser into the gas column using an axicon lens setup. The Bessel profile of the axicon setup creates a region of high intensity that can stretch over the full length of the gas column with approximately constant diameter. In this region of high intensity, the alkali metal vapor is ionized through multi-photon ionization process. In this manner, a fully ionized meter scale plasma of uniform density can be formed. Methods for controlling the plasma diameter and length will also be discussed.

  3. Meter scale plasma source for plasma wakefield experiments

    Energy Technology Data Exchange (ETDEWEB)

    Vafaei-Najafabadi, N.; Shaw, J. L.; Marsh, K. A.; Joshi, C.; Hogan, M. J. [Department of Electrical Engineering, University of California Los Angeles, Los Angeles, CA 90095 (United States); SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States)

    2012-12-21

    High accelerating gradients generated by a high density electron beam moving through plasma has been used to double the energy of the SLAC electron beam [1]. During that experiment, the electron current density was high enough to generate its own plasma without significant head erosion. In the newly commissioned FACET facility at SLAC, the peak current will be lower and without pre-ionization, head erosion will be a significant challenge for the planned experiments. In this work we report on our design of a meter scale plasma source for these experiments to effectively avoid the problem of head erosion. The plasma source is based on a homogeneous metal vapor gas column that is generated in a heat pipe oven [2]. A lithium oven over 30 cm long at densities over 10{sup 17} cm{sup -3} has been constructed and tested at UCLA. The plasma is then generated by coupling a 10 TW short pulse Ti:Sapphire laser into the gas column using an axicon lens setup. The Bessel profile of the axicon setup creates a region of high intensity that can stretch over the full length of the gas column with approximately constant diameter. In this region of high intensity, the alkali metal vapor is ionized through multi-photon ionization process. In this manner, a fully ionized meter scale plasma of uniform density can be formed. Methods for controlling the plasma diameter and length will also be discussed.

  4. Plasma-based EUV light source

    Science.gov (United States)

    Shumlak, Uri; Golingo, Raymond; Nelson, Brian A.

    2010-11-02

    Various mechanisms are provided relating to plasma-based light source that may be used for lithography as well as other applications. For example, a device is disclosed for producing extreme ultraviolet (EUV) light based on a sheared plasma flow. The device can produce a plasma pinch that can last several orders of magnitude longer than what is typically sustained in a Z-pinch, thus enabling the device to provide more power output than what has been hitherto predicted in theory or attained in practice. Such power output may be used in a lithography system for manufacturing integrated circuits, enabling the use of EUV wavelengths on the order of about 13.5 nm. Lastly, the process of manufacturing such a plasma pinch is discussed, where the process includes providing a sheared flow of plasma in order to stabilize it for long periods of time.

  5. The 2017 Plasma Roadmap: Low temperature plasma science and technology

    Science.gov (United States)

    Adamovich, I.; Baalrud, S. D.; Bogaerts, A.; Bruggeman, P. J.; Cappelli, M.; Colombo, V.; Czarnetzki, U.; Ebert, U.; Eden, J. G.; Favia, P.; Graves, D. B.; Hamaguchi, S.; Hieftje, G.; Hori, M.; Kaganovich, I. D.; Kortshagen, U.; Kushner, M. J.; Mason, N. J.; Mazouffre, S.; Mededovic Thagard, S.; Metelmann, H.-R.; Mizuno, A.; Moreau, E.; Murphy, A. B.; Niemira, B. A.; Oehrlein, G. S.; Petrovic, Z. Lj; Pitchford, L. C.; Pu, Y.-K.; Rauf, S.; Sakai, O.; Samukawa, S.; Starikovskaia, S.; Tennyson, J.; Terashima, K.; Turner, M. M.; van de Sanden, M. C. M.; Vardelle, A.

    2017-08-01

    Journal of Physics D: Applied Physics published the first Plasma Roadmap in 2012 consisting of the individual perspectives of 16 leading experts in the various sub-fields of low temperature plasma science and technology. The 2017 Plasma Roadmap is the first update of a planned series of periodic updates of the Plasma Roadmap. The continuously growing interdisciplinary nature of the low temperature plasma field and its equally broad range of applications are making it increasingly difficult to identify major challenges that encompass all of the many sub-fields and applications. This intellectual diversity is ultimately a strength of the field. The current state of the art for the 19 sub-fields addressed in this roadmap demonstrates the enviable track record of the low temperature plasma field in the development of plasmas as an enabling technology for a vast range of technologies that underpin our modern society. At the same time, the many important scientific and technological challenges shared in this roadmap show that the path forward is not only scientifically rich but has the potential to make wide and far reaching contributions to many societal challenges.

  6. Livermore Accelerator Source for Radionuclide Science (LASRS)

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Scott [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Bleuel, Darren [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Johnson, Micah [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Rusnak, Brian [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Soltz, Ron [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Tonchev, Anton [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-05-05

    The Livermore Accelerator Source for Radionuclide Science (LASRS) will generate intense photon and neutron beams to address important gaps in the study of radionuclide science that directly impact Stockpile Stewardship, Nuclear Forensics, and Nuclear Material Detection. The co-location of MeV-scale neutral and photon sources with radiochemical analytics provides a unique facility to meet current and future challenges in nuclear security and nuclear science.

  7. Plasma sources of solar system magnetospheres

    CERN Document Server

    Blanc, Michel; Chappell, Charles; Krupp, Norbert

    2016-01-01

    This volume reviews what we know of the corresponding plasma source for each intrinsically magnetized planet. Plasma sources fall essentially in three categories: the solar wind, the ionosphere (both prevalent on Earth), and the satellite-related sources. Throughout the text, the case of each planet is described, including the characteristics, chemical composition and intensity of each source. The authors also describe how the plasma generated at the source regions is transported to populate the magnetosphere, and how it is later lost. To summarize, the dominant sources are found to be the solar wind and sputtered surface ions at Mercury, the solar wind and ionosphere at Earth (the relative importance of the two being discussed in a specific introductory chapter), Io at Jupiter and – a big surprise of the Cassini findings – Enceladus at Saturn. The situation for Uranus and Neptune, which were investigated by only one fly-by each, is still open and requires further studies and exploration. In the final cha...

  8. Plasmas in compact traps: From ion sources to multidisciplinary research

    Science.gov (United States)

    Mascali, D.; Musumarra, A.; Leone, F.; Galatà, A.; Romano, F. P.; Gammino, S.

    2017-09-01

    In linear (minimum-B) magneto-static traps dense and hot plasmas are heated by electromagnetic radiation in the GHz domain via the Electron Cyclotron Resonance (ECR). The values of plasma density, temperature and confinement times ( n_eτ_i>10^{13} cm ^{-3} s; T_e>10 keV) are similar to the ones of thermonuclear plasmas. The research in this field -devoted to heating and confinement optimization- has been supported by numerical modeling and advanced diagnostics, for probing the plasma especially in a non-invasive way. ECR-based systems are nowadays able to produce extremely intense (tens or hundreds of mA) beams of light ions (p, d, He), and relevant currents of heavier elements (C, O, N) up to heavy ions like Xe, Pb, U. Such beams can be extracted from the trap by a proper electrostatic system. The above-mentioned properties make these plasmas very attractive for interdisciplinary researches also, such as i) nuclear decays rates measurements in stellar-like conditions, ii) energy conversion studies, being exceptional sources of short-wavelength electromagnetic radiation (EUV, X-rays, hard X-rays and gammas, useful in material science and archaeometry), iii) environments allowing precise spectroscopical measurements as benchmarks for magnetized astrophysical plasmas. The talk will give an overview about the state-of-the-art in the field of intense ion sources, and some new perspectives for interdisciplinary research, with a special attention to the developments based at INFN-LNS.

  9. Comparison of Plasma Activation of Thin Water Layers by Direct and Remote Plasma Sources

    Science.gov (United States)

    Kushner, Mark

    2014-10-01

    Plasma activation of liquids is now being investigated for a variety of biomedical applications. The plasma sources used for this activation can be generally classified as direct (the plasma is in contact with the surface of the liquid) or remote (the plasma does not directly touch the liquid). The direct plasma source may be a dielectric barrier discharge (DBD) where the surface of the liquid is a floating electrode or a plasma jet in which the ionization wave forming the plasma plume reaches the liquid. The remote plasma source may be a DBD with electrodes electrically isolated from the liquid or a plasma jet in which the ionization wave in the plume does not reach the liquid. In this paper, a comparison of activation of thin water layers on top of tissue, as might be encountered in wound healing, will be discussed using results from numerical investigations. We used the modeling platform nonPDPSIM to simulate direct plasma activation of thin water layers using DBDs and remote activation using plasma jets using up to hundreds of pulses. The DBDs are sustained in humid air while the plasma jets consist of He/O2 mixtures flowed into humid air. For similar number of pulses and energy deposition, the direct DBD plasma sources produce more acidification and higher production of nitrates/nitrites in the liquid. This is due to the accumulation of NxOy plasma jets, the convective flow removes many of these species prior to their diffusing into the water or reacting to form higher nitrogen oxides. This latter effect is sensitive to the repetition rate which determines whether reactive species formed during prior pulses overlap with newly produced reactive species. in the gas phase. In the plasma jets, the convective flow removes many of these species prior to their diffusing into the water or reacting to form higher nitrogen oxides. This latter effect is sensitive to the repetition rate which determines whether reactive species formed during prior pulses overlap with

  10. A Microfabricated Inductively Coupled Plasma Excitation Source

    Institute of Scientific and Technical Information of China (English)

    WANG Yong-Qing; PU Yong-Ni; SUN Rong-Xia; TANG Yu-Jun; CHEN Wen-Jun; LOU Jian-Zhong; MA Wen

    2008-01-01

    A novel miniaturization of inductively coupled plasma(ICP)source based on printed circuit produced using micro-fabrication techniques is presented.The basic parameters of the novel ICP,including its radio frequency,power loss,size,and argon consumption are less than 1% of that for the case of atmospheric pressure ICP source.For example,at 100 Pa of argon gas pressure,the present ICP source can be ignited by using the rf power less than 3.5 W.Potential applications of the ICP is discussed.

  11. Radio and Plasma Waves Synergistic Science Opportunities with EJSM

    Science.gov (United States)

    Cecconi, Baptiste; André, Nicolas; Bougeret, Jean-Louis

    2010-05-01

    The radio and plasma wave (RPW) diagnostics provide a unique access to critical parameters of space plasma, in particular in planetary and satellite environments. Concerning giant planets, this has been demonstrated by major results obtained by the radio investigation on the Galileo and Cassini spacecraft, but also during the Ulysses, Voyager, and Pioneer flybys of Jupiter. Several other missions, past or in flight, demonstrate the uniqueness and relevance of RPW diagnostics to basic problems of astrophysics. The EJSM mission consists of two platforms operating in the Jupiter environment: the NASA-led Jupiter Europa Orbiter (JEO), and the ESA-led Jupiter Ganymede Orbiter (JGO). JEO and JGO will execute a choreographed exploration of the Jupiter System before settling into orbit around Europa and Ganymede, respectively. The EJSM mission architecture hence offers unique opportunities for synergistic and complementary observations that significantly enhance the overall science return of the mission. In this paper, we will first review new and unique science aspects of the Jupiter system that may benefit from different capabilities of RPW investigations onboard JGO and/or JEO: spectral and polarization information, mapping of radio sources, measurements of in situ plasma waves, currents, thermal noise, dust and nano-particle detection and characterization. We will then illustrate unique synergistic and complementary science opportunities offered by RPW investigations onboard JGO and/or JEO, both in terms of Satellite science and in terms of Magnetospheric Science.

  12. Plasma wake field XUV radiation source

    Energy Technology Data Exchange (ETDEWEB)

    Prono, Daniel S. (Los Alamos, NM); Jones, Michael E. (Los Alamos, NM)

    1997-01-01

    A XUV radiation source uses an interaction of electron beam pulses with a gas to create a plasma radiator. A flowing gas system (10) defines a circulation loop (12) with a device (14), such as a high pressure pump or the like, for circulating the gas. A nozzle or jet (16) produces a sonic atmospheric pressure flow and increases the density of the gas for interacting with an electron beam. An electron beam is formed by a conventional radio frequency (rf) accelerator (26) and electron pulses are conventionally formed by a beam buncher (28). The rf energy is thus converted to electron beam energy, the beam energy is used to create and then thermalize an atmospheric density flowing gas to a fully ionized plasma by interaction of beam pulses with the plasma wake field, and the energetic plasma then loses energy by line radiation at XUV wavelengths Collection and focusing optics (18) are used to collect XUV radiation emitted as line radiation when the high energy density plasma loses energy that was transferred from the electron beam pulses to the plasma.

  13. Research briefing on contemporary problems in plasma science

    Science.gov (United States)

    1991-01-01

    An overview is presented of the broad perspective of all plasma science. Detailed discussions are given of scientific opportunities in various subdisciplines of plasma science. The first subdiscipline to be discussed is the area where the contemporary applications of plasma science are the most widespread, low temperature plasma science. Opportunities for new research and technology development that have emerged as byproducts of research in magnetic and inertial fusion are then highlighted. Then follows a discussion of new opportunities in ultrafast plasma science opened up by recent developments in laser and particle beam technology. Next, research that uses smaller scale facilities is discussed, first discussing non-neutral plasmas, and then the area of basic plasma experiments. Discussions of analytic theory and computational plasma physics and of space and astrophysical plasma physics are then presented.

  14. Overdense plasma generation in a compact ion source

    Science.gov (United States)

    Castro, G.; Mascali, D.; Gammino, S.; Torrisi, G.; Romano, F. P.; Celona, L.; Altana, C.; Caliri, C.; Gambino, N.; Lanaia, D.; Miracoli, R.; Neri, L.; Sorbello, G.

    2017-05-01

    Electron cyclotron resonance ion sources (ECRIS) are widely used plasma based machines for the production of intense ion beams in science and industry. The performance of modern devices is limited by the presence of the density cut-off, above which electromagnetic (EM) waves sustaining the plasma are reflected. We hereby discuss the systematic data analysis of electrostatic wave generation in an ECR prototype operating at 3.75 GHz-0.1 THz. In particular, electron Bernstein waves (EBW) have been excited. EBW have already been generated in large-scale plasma devices for thermonuclear fusion purposes. In ion sources where L c ˜ λ RF (L c being the plasma chamber size and λ RF the pumping wave wavelength) the EM field assumes a modal behaviour; thus both plasma and EM field self-organize so that no optical-like wave launching is possible (i.e. the cavity effect dominates on the optical path). The collected data, however, supported by 3D full-wave simulations, actually demonstrate that a Budden-type X-B conversion scenario can be established above some critical RF power thresholds, operating in an off-ECR regime. The generation and absorption of the EBW has been demonstrated by the presence of three peculiar signatures: along with the establishment of an overdense plasma, generation of supra-thermal electrons and modification (non-linear broadening) of the EM spectrum measured within the plasma have been observed. At the threshold establishing such a heating regime, the collected data provide evidence for a fast rotation of the electron fluid.

  15. Speciation analysis by gas chromatography with plasma source spectrometric detection

    Science.gov (United States)

    Łobiński, Ryszard; Adams, Freddy C.

    State-of-the-art species-selective analysis by gas chromatography (GC) with plasma source spectrometric detection is discussed for organometal and organometalloid compounds. Various plasmas, inductively coupled plasma, microwave induced plasma, capacitatively coupled plasma, direct current plasma and alternating current plasma, are characterized and critically compared as sources of radiation for atomic emission spectrometry and sources of ions for mass spectrometry. Interfaces between gas chromatography (packed, wide-bore, capillary and multicapillary) and plasma source spectrometry are characterized. Particular emphasis is given to applications of GC with plasma source detection to real-world analytical problems, which are comprehensively reviewed. The use of plasmas for the acquisition of auxiliary molecular information such as empirical formulae and structural information is discussed. Recent developments relating to sample preparation and presentation to the hyphenated system are addressed. The most significant trends in speciation analysis are highlighted.

  16. Plasma-Based Ion Beam Sources

    Energy Technology Data Exchange (ETDEWEB)

    Loeb, H. W.

    2005-07-01

    Ion beam sources cover a broad spectrum of scientific and technical applications delivering ion currents between less than 1 mA and about 100 A at acceleration voltages between 100 V and 100 kV. The ions are mostly generated by electron collisions in a gas discharge and then extracted from the discharge plasma, focused and post-accelerated by single- or multi-aperture electrode systems. Some important applications require the neutralization of the exhausted beam either by charge exchange or by admixture of electrons. In the first part of the paper, the theory of ionization by electron impact, the energy and carrier balances in the plasma, and the extraction and focusing mechanisms will be outlined. The principles of the preferred gas discharges and of the ion beam sources based on them are discussed; i.e. of the Penning, bombardment, arc, duoplasmatron, radio frequency, and microwave types. In the second part of the paper, the special requirements of the different applications are described together with the related source hardware. One distinguishes: 1. Single-aperture ion sources producing protons, heavy ions, isotope ions, etc. for particle accelerators, ion microprobes, mass spectrometers, isotope separators, etc.; quality determinative quantities are brightness, emittance, energy width, etc. 2. Broad-beam multi-aperture injector sources for fusion machines with positive or negative deuterium ions; very high beam densities, small portions of molecular ions, flat beam profiles with small divergence angles, etc. are required. 3. Broad-beam multi-aperture ion thrusters for space propulsion operated with singly charged xenon ions; high efficiencies, reliable operation, and long lifetimes are most important. Spin-offs are applied in industry for material processing. Referring to these applications, the following sources will be described in some detail: 1. Cold cathode and filament driven sources, capillary arc and plasmatron types, microwave and ECR-sources. 2

  17. 21 CFR 640.74 - Modification of Source Plasma.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Modification of Source Plasma. 640.74 Section 640...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.74 Modification of Source Plasma. (a) Upon approval by the Director, Center for Biologics Evaluation and Research, Food and...

  18. Plasma source mass spectrometry in experimental nutrition.

    Science.gov (United States)

    Barnes, R M

    1998-01-01

    The development and commercial availability of plasma ion source, specifically inductively coupled plasma, mass spectrometers (ICP-MS) have significantly extended the potential application of stable isotopes for nutritional modeling. The status of research and commercial ICP-MS instruments, and their applications and limitations for stable isotopic studies are reviewed. The consequences of mass spectroscopic resolution and measurement sensitivity obtainable with quadrupole, sector, time-of-flight, and trap instruments on stable isotope analysis are examined. Requirements for reliable isotope measurements with practical biological samples including tissues and fluids are considered. The possibility for stable isotope analysis in chemically separated compounds (speciation) also is explored. On-line compound separations by chromatography or electrophoresis, for example, have been combined instrumentally with ICP-MS. Som possibilities and requirements are described for stable isotope speciation analysis.

  19. Magnetic plasma confinement for laser ion source.

    Science.gov (United States)

    Okamura, M; Adeyemi, A; Kanesue, T; Tamura, J; Kondo, K; Dabrowski, R

    2010-02-01

    A laser ion source (LIS) can easily provide a high current beam. However, it has been difficult to obtain a longer beam pulse while keeping a high current. On occasion, longer beam pulses are required by certain applications. For example, more than 10 micros of beam pulse is required for injecting highly charged beams to a large sized synchrotron. To extend beam pulse width, a solenoid field was applied at the drift space of the LIS at Brookhaven National Laboratory. The solenoid field suppressed the diverging angle of the expanding plasma and the beam pulse was widened. Also, it was observed that the plasma state was conserved after passing through a few hundred gauss of the 480 mm length solenoid field.

  20. Laser-produced plasma source system development

    Science.gov (United States)

    Fomenkov, Igor V.; Brandt, David C.; Bykanov, Alexander N.; Ershov, Alexander I.; Partlo, William N.; Myers, David W.; Böwering, Norbert R.; Vaschenko, Georgiy O.; Khodykin, Oleh V.; Hoffman, Jerzy R.; Vargas L., Ernesto; Simmons, Rodney D.; Chavez, Juan A.; Chrobak, Christopher P.

    2007-03-01

    This paper describes the development of laser produced plasma (LPP) technology as an EUV source for advanced scanner lithography applications in high volume manufacturing. EUV lithography is expected to succeed 193 nm immersion technology for critical layer patterning below 32 nm beginning with beta generation scanners in 2009. This paper describes the development status of subsystems most critical to the performance to meet joint scanner manufacturer requirements and semiconductor industry standards for reliability and economic targets for cost of ownership. The intensity and power of the drive laser are critical parameters in the development of extreme ultraviolet LPP lithography sources. The conversion efficiency (CE) of laser light into EUV light is strongly dependent on the intensity of the laser energy on the target material at the point of interaction. The total EUV light generated then scales directly with the total incident laser power. The progress on the development of a short pulse, high power CO2 laser for EUV applications is reported. The lifetime of the collector mirror is a critical parameter in the development of extreme ultra-violet LPP lithography sources. The deposition of target materials and contaminants, as well as sputtering of the collector multilayer coating and implantation of incident particles can reduce the reflectivity of the mirror substantially over the exposure time even though debris mitigation schemes are being employed. The results of measurements of high energy ions generated by a short-pulse CO2 laser on a laser-produced plasma EUV light source with Sn target are presented. Droplet generation is a key element of the LPP source being developed at Cymer for EUV lithography applications. The main purpose of this device is to deliver small quantities of liquid target material as droplets to the laser focus. The EUV light in such configuration is obtained as a result of creating a highly ionized plasma from the material of the

  1. New science at the European Spallation Source

    Energy Technology Data Exchange (ETDEWEB)

    Finney, J.L. [University Coll., London (United Kingdom). Dept. of Physics and Astronomy

    1996-05-01

    The European Spallation Source is a trans-European project aimed at the ultimate construction of a next-generation pulsed spallation neutron source that will deliver 30 times the beam power of ISIS. The reference design for the proposed source has been set, and work is in progress to develop an updated scientific case for the construction of the source early in the next century. Together with improvements in instrumentation, effective flux gains of over two orders of magnitude are likely in some areas, opening up major new opportunities for the exploitation of neutron studies in fundamental, strategic, and applied science. (author)

  2. Dynamics of Ion Beam Charge Neutralization by Ferroelectric Plasma Sources

    Science.gov (United States)

    Stepanov, Anton D.; Gilson, Erik P.; Grisham, Larry R.; Kaganovich, Igor D.; Davidson, Ronald C.; Ji, Qing; Persaud, Arun; Seidl, Peter A.; Schenkel, Thomas

    2016-10-01

    Ferroelectric Plasma Sources (FEPSs) can generate plasma that provides effective space-charge neutralization of intense high-perveance ion beams. Here we present experimental results on charge neutralization of a high-perveance 38 keV Ar+ beam by a FEPS plasma. By comparing the measured beam radius with the envelope model for space-charge expansion, it is shown that a charge neutralization fraction of 98% is attainable. The transverse electrostatic potential of the ion beam is reduced from 15 V before neutralization to 0.3 V, implying that the energy of the neutralizing electrons is below 0.3 eV. Near-complete charge neutralization is established 5 μs after the driving pulse is applied to the FEPS, and can last for 35 μs. It is argued that the duration of neutralization is much longer than a reasonable lifetime of the plasma produced in the sub- μs surface discharge. Measurements of current flow in the driving circuit of the FEPS suggest that plasma can be generated for tens of μs after the high voltage pulse is applied. This is confirmed by fast photography of the plasma in the 1-meter long FEPS on NDCX-II, where effective charge neutralization of the beam was achieved with the optimized FEPS timing. This work was supported by the Office of Science of the US Department of Energy under contracts DE-AC0209CH11466 (PPPL) and DE-AC0205CH11231 (LBNL).

  3. Dense Plasma Focus - From Alternative Fusion Source to Versatile High Energy Density Plasma Source for Plasma Nanotechnology

    Science.gov (United States)

    Rawat, R. S.

    2015-03-01

    The dense plasma focus (DPF), a coaxial plasma gun, utilizes pulsed high current electrical discharge to heat and compress the plasma to very high density and temperature with energy densities in the range of 1-10 × 1010 J/m3. The DPF device has always been in the company of several alternative magnetic fusion devices as it produces intense fusion neutrons. Several experiments conducted on many different DPF devices ranging over several order of storage energy have demonstrated that at higher storage energy the neutron production does not follow I4 scaling laws and deteriorate significantly raising concern about the device's capability and relevance for fusion energy. On the other hand, the high energy density pinch plasma in DPF device makes it a multiple radiation source of ions, electron, soft and hard x-rays, and neutrons, making it useful for several applications in many different fields such as lithography, radiography, imaging, activation analysis, radioisotopes production etc. Being a source of hot dense plasma, strong shockwave, intense energetic beams and radiation, etc, the DPF device, additionally, shows tremendous potential for applications in plasma nanoscience and plasma nanotechnology. In the present paper, the key features of plasma focus device are critically discussed to understand the novelties and opportunities that this device offers in processing and synthesis of nanophase materials using, both, the top-down and bottom-up approach. The results of recent key experimental investigations performed on (i) the processing and modification of bulk target substrates for phase change, surface reconstruction and nanostructurization, (ii) the nanostructurization of PLD grown magnetic thin films, and (iii) direct synthesis of nanostructured (nanowire, nanosheets and nanoflowers) materials using anode target material ablation, ablated plasma and background reactive gas based synthesis and purely gas phase synthesis of various different types of

  4. A New Atmospheric Pressure Microwave Plasma Source (APMPS)

    Institute of Scientific and Technical Information of China (English)

    LIU Liang; ZHANG Guixin; LI Yinan; ZHU Zhijie; WANG Xinxin; LUO Chengmu

    2008-01-01

    An atmospheric pressure microwave plasma source (APMPS) that can generate a large volume of plasma at an atmospheric pressure has been developed at Tsinghua University. This paper presents the design of this APMPS, the theoretical consideration of microwave plasma ignition and the simulation results, including the distributions of the electric field and power density inside the cavity as well as the accuracy of the simulation results. In addition, a method of producing an atmospheric pressure microwave plasma and some relevant observations of the plasma are also provided. It. is expected that this research would be useful for further developing atmospheric pressure microwave plasma sources and expanding the scope of their applications.

  5. Potential applications of an electron cyclotron resonance multicusp plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, C.C.; Berry, L.A.; Gorbatkin, S.M.; Haselton, H.H.; Roberto, J.B.; Stirling, W.L. (Oak Ridge National Laboratory, Oak Ridge, TN (USA))

    1990-05-01

    An electron cyclotron resonance (ECR) multicusp plasmatron has been developed by feeding a multicusp bucket arc chamber with a compact ECR plasma source. This novel source produces large (about 25 cm diam), uniform (to within {plus minus}10%), dense ({gt}10{sup 11} cm{sup {minus}3}) plasmas of argon, helium, hydrogen, and oxygen. It has been operated to produce an oxygen plasma for etching 12.7 cm (5 in.) positive photoresist-coated silicon wafers with uniformity within {plus minus}8%. Results and potential applications of this new ECR plasma source for plasma processing of thin films are discussed.

  6. Ions beams and ferroelectric plasma sources

    Science.gov (United States)

    Stepanov, Anton

    Near-perfect space-charge neutralization is required for the transverse compression of high perveance ion beams for ion-beam-driven warm dense matter experiments, such as the Neutralized Drift Compression eXperiment (NDCX). Neutralization can be accomplished by introducing a plasma in the beam path, which provides free electrons that compensate the positive space charge of the ion beam. In this thesis, charge neutralization of a 40 keV, perveance-dominated Ar+ beam by a Ferroelectric Plasma Source (FEPS) is investigated. First, the parameters of the ion beam, such as divergence due to the extraction optics, charge neutralization fraction, and emittance were measured. The ion beam was propagated through the FEPS plasma, and the effects of charge neutralization were inferred from time-resolved measurements of the transverse beam profile. In addition, the dependence of FEPS plasma parameters on the configuration of the driving pulser circuit was studied to optimize pulser design. An ion accelerator was constructed that produced a 30-50 keV Ar + beam with pulse duration angle divergence of 0.87°. The measurements show that near-perfect charge neutralization with FEPS can be attained. No loss of ion beam current was detected, indicating the absence of a neutral cloud in the region of beam propagation, which would cause beam loss to charge exchange collisions. This provides evidence in favor of using FEPS in a future Heavy Ion Fusion accelerator. The FEPS discharge was investigated based on current-voltage measurements in the pulser circuit. Different values of series resistance and storage capacitance in the pulser circuit were used. The charged particle current emitted by the FEPS into vacuum was measured from the difference in forward and return currents in the driving circuit. It was found that FEPS is an emitter of negative charge, and that electron current emission begins approximately 0.5 mus after the fast-rising high voltage pulse is applied and lasts for tens

  7. 20. AINSE plasma science and technology conference. Conference handbook

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-31

    The 20th AINSE plasma science and technology conference was held at Flinders University of South Australia on 13-14 February 1995. Topics under discussion included plasma physics studies, current status of rotamak devices, plasma processing and material studies. The handbook contains the conference program, 54 abstracts and a list of participants.

  8. Focused ion beams using a high-brightness plasma source

    Science.gov (United States)

    Guharay, Samar

    2002-10-01

    High-brightness ion beams, with low energy spread, have merits for many new applications in microelectronics, materials science, and biology. Negative ions are especially attractive for the applications that involve beam-solid interactions. When negative ions strike a surface, especially an electrically isolated surface, the surface charging voltage is limited to few volts [1]. This property can be effectively utilized to circumvent problems due to surface charging, such as device damage and beam defocusing. A compact plasma source, with the capability to deliver either positive or negative ion beams, has been developed. H- beams from this pulsed source showed brightness within an order of magnitude of the value for beams from liquid-metal ion sources. The beam angular intensity is > 40 mAsr-1 and the corresponding energy spread is 1 Acm-2 and a spot size of 100 nm. Such characteristics of focused beam parameters, using a dc source, will immediately open up a large area of new applications. [1] P. N. Guzdar, A. S. Sharma, S. K. Guharay, "Charging of substrates irradiated by particle beams" Appl. Phys. Lett. 71, 3302 (1997). [2] S. K. Guharay, E. Sokolovsky, J. Orloff, "Characteristics of ion beams from a Penning source for focused ion beam applications" J. Vac. Sci Technol. B17, 2779 (1999).

  9. Spectroscopic characterization of atmospheric pressure um-jet plasma source

    CERN Document Server

    Bibinov, Nikita; Bahre, Hendrik; Awakowicz, Peter; der Gathen, Volker Schulz-von

    2011-01-01

    A radio frequency um-jet plasma source is studied using He/O2 mixture. This um-jet can be used for different applications as a source of chemical active species e.g. oxygen atoms, molecular metastables and ozone. Using absolutely-calibrated optical emission spectroscopy and numerical simulation, the gas temperature in active plasma region and plasma parameters (electron density and electron distribution function) are determined. Concentrations of oxygen atoms and ozone in the plasma channel and in the effluent of the plasma source are measured using emission and absorption spectroscopy. To interpret the measured spatial distributions, the steady-state species' concentrations are calculated using determined plasma parameters and gas temperature. At that the influence of the surface processes and gas flow regime on the loss of the active species in the plasma source are discussed. The measured spatial distributions of oxygen atom and ozone densities are compared with the simulated ones.

  10. Potential applications of an electron cyclotron resonance multicusp plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, C.C.; Berry, L.A.; Gorbatkin, S.M.; Haselton, H.H.; Roberto, J.B.; Schechter, D.E.; Stirling, W.L.

    1990-03-01

    An electric cyclotron resonance (ECR) multicusp plasmatron has been developed by feeding a multicusp bucket arc chamber with a compact ECR plasma source. This novel source produces large (about 25-cm- diam), uniform (to within {plus minus}10%), dense (>10{sup 11}--cm{sup {minus}3}) plasmas of argon, helium, hydrogen, and oxygen. It has been operated to produce an oxygen plasma for etching 12.7-cm (5-in.) positive photoresist-coated silicon wafers with uniformity within {plus minus}8%. Following a brief review of the large plasma source developed at Oak Ridge National Laboratory, the configuration and operation of the source are described and a discharge model is presented. Results from this new ECR plasma source and potential applications for plasma processing of thin films are discussed. 21 refs., 10 figs.

  11. Town Meeting on Plasma Physics at the National Science Foundation

    Science.gov (United States)

    2015-11-01

    We invite you to the Town Meeting on the role of the National Science Foundation (NSF) in supporting basic and applied research in Plasma Physics in the U.S. The overarching goal of NSF is to promote the progress of science and to enable training of the next generation of scientists and engineers at US colleges and universities. In this context, the role of the NSF Physics Division in leading the nearly 20 year old NSF/DOE Partnership in Basic Plasma Science and Engineering serves as an example of the long history of NSF support for basic plasma physics research. Yet, the NSF interest in maintaining a healthy university research base in plasma sciences extends across the Foundation. A total of five NSF Divisions are participating in the most recent Partnership solicitation, and a host of other multi-disciplinary and core programs provide opportunities for scientists to perform research on applications of plasma physics to Space & Solar Physics, Astrophysics, Accelerator Science, Material Science, Plasma Medicine, and many sub-disciplines within Engineering. This Town Meeting will provide a chance to discuss the full range of relevant NSF funding opportunities, and to begin a conversation on the present and future role of NSF in stewarding basic plasma science and engineering research at US colleges and universities. We would like to particularly encourage early career scientists and graduate students to participate in this Town Meeting, though everyone is invited to join what we hope to be a lively discussion.

  12. Multifunctional bulk plasma source based on discharge with electron injection

    Energy Technology Data Exchange (ETDEWEB)

    Klimov, A. S.; Medovnik, A. V. [Tomsk State University of Control Systems and Radioelectronics, Tomsk 634050 (Russian Federation); Tyunkov, A. V. [Tomsk State University of Control Systems and Radioelectronics, Tomsk 634050 (Russian Federation); Institute of High Current Electronics, Tomsk 634055 (Russian Federation); Savkin, K. P.; Shandrikov, M. V.; Vizir, A. V. [Institute of High Current Electronics, Tomsk 634055 (Russian Federation)

    2013-01-15

    A bulk plasma source, based on a high-current dc glow discharge with electron injection, is described. Electron injection and some special design features of the plasma arc emitter provide a plasma source with very long periods between maintenance down-times and a long overall lifetime. The source uses a sectioned sputter-electrode array with six individual sputter targets, each of which can be independently biased. This discharge assembly configuration provides multifunctional operation, including plasma generation from different gases (argon, nitrogen, oxygen, acetylene) and deposition of composite metal nitride and oxide coatings.

  13. European Spallation Source and Neutron Science

    Science.gov (United States)

    Yeck, James

    2014-03-01

    International collaborations in large-scale scientific projects can link Sciences and Society. Following this goal, the European Spallation Source (ESS) is a multi-disciplinary research centre under design and construction in Lund, Sweden. This new facility is funded by a collaboration of 17 European countries. Scandinavia is providing 50 percent of the construction cost whilst the other member states are providing financial support mainly via in-kind contribution from institutes, laboratories or industries of the given countries. Scientists and engineers from 35 different countries are members of the workforce in Lund who participate in its design and construction. The ESS will enable new opportunities for researchers in fields of life sciences, energy, environmental technology, cultural heritage and fundamental physics by producing very high flux neutrons to study condensed matter physics, chemistry, biology, nuclear physics and materials science. The ESS will be up to 30 times brighter than today's leading facilities and neutron sources. A tungsten target and a 5 MW long pulse proton accelerator, composed mainly of superconducting Radio-Frequency components, are used to achieve these goals.

  14. PIC/MCC simulation for magnetized capacitively coupled plasmas driven by combined dc/rf sources

    Science.gov (United States)

    Yang, Shali; Zhang, Ya; Jiang, Wei; Wang, Hongyu; Wang, Shuai

    2016-09-01

    Hybrid dc/rf capacitively coupled plasma (CCP) sources have been popular in substrate etching due to their simplicity in the device structure and better plasma property. In this work, the characteristics of magnetized capacitively coupled plasmas driven by combined dc/rf sources are described by a one-dimensional Particle-in-cell/Monte Carlo collision (PIC/MCC) model. The simulation is using a rf source of 13.56MHz in argon and at a low pressure of 50mTorr. The effects of dc voltage and magnetic field on the plasmas are examined for 200-400V and 0-200Gs. It is found that, to some extent, dc voltage will increase the plasma density, but plasma density drops with increasing dc voltage. The magnetic field will enhance the plasma density significantly, due to the magnetic field will increase the electron life time and decrease the loss to the electrodes. In the bulk plasma, electron temperature is increased with the magnetic field but decreased with the dc voltage. The electron temperature in sheath is higher than in bulk plasma, due to stochastic heating in sheath is greater than Ohmic heating in bulk plasma under low gas pressure. National Natural Science Foundation of China (11405067, 11105057, 11305032, 11275039).

  15. Antitumor action of non thermal plasma sources, DBD and Plasma Gun, alone or in combined protocols

    Science.gov (United States)

    Robert, Eric; Brullé, Laura; Vandamme, Marc; Riès, Delphine; Le Pape, Alain; Pouvesle, Jean-Michel

    2012-10-01

    The presentation deals with the assessment on two non thermal plasma sources developed and optimized for oncology applications. The first plasma source is a floating-electrode dielectric barrier discharge powered at a few hundreds of Hz which deliver air-plasma directly on the surface of cell culture medium in dishes or on the skin or organs of mice bearing cancer tumors. The second plasma source, so called Plasma Gun, is a plasma jet source triggered in noble gas, transferred in high aspect ratio and flexible capillaries, on targeting cells or tumors after plasma transfer in air through the ``plasma plume'' generated at the capillary outlet. In vitro evidence for massive cancer cell destruction and in vivo tumor activity and growth rate reductions have been measured with both plasma sources. DNA damages, cell cycle arrests and apoptosis induction were also demonstrated following the application of any of the two plasma source both in vitro and in vivo. The comparison of plasma treatment with state of the art chemotherapeutic alternatives has been performed and last but not least the benefit of combined protocols involving plasma and chemotherapeutic treatments has been evidenced for mice bearing orthotopic pancreas cancer and is under evaluation for the colon tumors.

  16. Space Plasma Science as a Motivator for Education & Outreach

    Science.gov (United States)

    Dusenbery, Paul

    1999-11-01

    Education and public outreach (EPO) continue to play an important role in how science is funded by the federal government. The plasma science community has a responsibility to share their exciting science with the American public. Bruce Alberts, president of the National Academy of Sciences, and Neal Lane, former head of NSF, are on record as strong advocates of scientists becoming more actively and effectively engaged in K-12 science education reform. In addition, research directorates of funding agencies like NASA and NSF are increasingly encouraging (and in some cases requiring) the integration of science and education and greater scientist involvement in EPO. How does plasma science and scientists fit into this broader political and social landscape? How well does the public understand our science and technology? Are there ways to effectively engage the public that provide good visibility for plasma science? These questions and more will be addressed in this talk. The Space Science Institute (SSI), a nonprofit organization in Colorado, provides national leadership in developing innovative ways to translate the activities and resources of space and earth science research into exciting and effective K-12 and museum education programs. SSI’s mission is to link its space science research enterprise with its education programs. SSI has active programs in curriculum and exhibit development and professional development for both scientists about education and for educators about science. I will share with you one exhibit project and one curriculum project whose goals are to raise public understanding of space plasmas and by extension all of plasma science.

  17. Spatial control of processing plasmas in a multicusp plasma source equipped with a movable magnetic filter

    Energy Technology Data Exchange (ETDEWEB)

    Fukumasa, O.; Naitou, H.; Sakiyama, S. (Yamaguchi Univ., Yamaguchi (Japan))

    1991-12-20

    The plasma chemical vapor deposition (p-CVD) method has been used in the preparation of various sorts of thin films such as hydrogenated amorphous silicon films and hydrogenated amorphous carbon films, etc. and the application feasibility of a magnetically filtered multicusp plasma source has been studied. In this paper, it is confirmed that plasma parameters (H {sub 2} - ch {sub 4} or Ar-CH {sub 4} plasmas) are spatially well controlled by using both a movable magnetic filter and a plasma grid. Plasma parameters change sharply across the magnetic filter at any filter position and the whole plasma is divided clearly into the region of source plasma with high-energy electrons and the region of diffused plasma without high-energy electrons. Concerning the role of the magnetic filter which reflects preferentially high-energy electrons, a study is made through computer simulation. 7 refs., 9 figs.

  18. Science and Technology of Future Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Dierker,S.; Bergmann, U.; Corlett, J.; Dierker, S.; Falcone, R.; Galayda, J.; Gibson, M.; Hastings, J.; Hettel, B.; Hill, J.; Hussain, Z.; Kao, C.-C.; Kirx, J.; Long, G.; McCurdy, B.; Raubenheimer, T.; Sannibale, F.; Seeman, J.; Shen, Z.-X.; Shenoy, g.; Schoenlein, B.; Shen, Q.; Stephenson, B.; Stohr, J.; Zholents, A.

    2008-12-01

    Many of the important challenges facing humanity, including developing alternative sources of energy and improving health, are being addressed by advances that demand the improved understanding and control of matter. While the visualization, exploration, and manipulation of macroscopic matter have long been technological goals, scientific developments in the twentieth century have focused attention on understanding matter on the atomic scale through the underlying framework of quantum mechanics. Of special interest is matter that consists of natural or artificial nanoscale building blocks defined either by atomic structural arrangements or by electron or spin formations created by collective correlation effects. The essence of the challenge to the scientific community has been expressed in five grand challenges for directing matter and energy recently formulated by the Basic Energy Sciences Advisory Committee [1]. These challenges focus on increasing our understanding of, and ultimately control of, matter at the level of atoms, electrons. and spins, as illustrated in Figure 1.1, and serve the entire range of science from advanced materials to life sciences. Meeting these challenges will require new tools that extend our reach into regions of higher spatial, temporal, and energy resolution. X-rays with energies above 10 keV offer capabilities extending beyond the nanoworld shown in Figure 1.1 due to their ability to penetrate into optically opaque or thick objects. This opens the door to combining atomic level information from scattering studies with 3D information on longer length scales from real space imaging with a resolution approaching 1 nm. The investigation of multiple length scales is important in hierarchical structures, providing knowledge about function of living organisms, the atomistic origin of materials failure, the optimization of industrial synthesis, or the working of devices. Since the fundamental interaction that holds matter together is of

  19. Science and Technology of Future Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Bergmann, Uwe; Corlett, John; Dierker, Steve; Falcone, Roger; Galayda, John; Gibson, Murray; Hastings, Jerry; Hettel, Bob; Hill, John; Hussain, Zahid; Kao, Chi-Chang; Kirz, Janos; Long, Danielle; McCurdy, Bill; Raubenheimer, Tor; Sannibale, Fernando; Seeman, John; Shen, Z. -X.; Schenoy, Gopal; Schoenlein, Bob; Shen, Qun; Stephenson, Brian; Stohr, Joachim; Zholents, Alexander

    2009-01-28

    Many of the important challenges facing humanity, including developing alternative sources of energy and improving health, are being addressed by advances that demand the improved understanding and control of matter. While the visualization, exploration, and manipulation of macroscopic matter have long been technological goals, scientific developments in the twentieth century have focused attention on understanding matter on the atomic scale through the underlying framework of quantum mechanics. Of special interest is matter that consists of natural or artificial nanoscale building blocks defined either by atomic structural arrangements or by electron or spin formations created by collective correlation effects The essence of the challenge to the scientific community has been expressed in five grand challenges for directing matter and energy recently formulated by the Basic Energy Sciences Advisory Committee. These challenges focus on increasing our understanding of, and ultimately control of, matter at the level of atoms, electrons. and spins, as illustrated in Figure 1.1, and serve the entire range of science from advanced materials to life sciences. Meeting these challenges will require new tools that extend our reach into regions of higher spatial, temporal, and energy resolution. X-rays with energies above 10 keV offer capabilities extending beyond the nanoworld shown in Figure 1.1 due to their ability to penetrate into optically opaque or thick objects. This opens the door to combining atomic level information from scattering studies with 3D information on longer length scales from real space imaging with a resolution approaching 1 nm. The investigation of multiple length scales is important in hierarchical structures, providing knowledge about function of living organisms, the atomistic origin of materials failure, the optimization of industrial synthesis, or the working of devices. Since the fundamental interaction that holds matter together is of

  20. s perception of mathematics science plasma lessons in ethiopia

    African Journals Online (AJOL)

    User

    Key words: education, plasma TV, mathematics, science, high school. *: Biology dept. AAU ... age-old teacher centered approach into .... qualitative through open ended questions .... federal ministry for classroom teachers use of lesson ...

  1. Cysteine as a Biological Probe for Comparing Plasma Sources

    Science.gov (United States)

    Lackmann, Jan-Wilm; Golda, Judith; Kogelheide, Friederike; Held, Julian; Schulz-von-der-Gathen, Volker; Stapelmann, Katharina

    2016-09-01

    A large variety of plasma sources are available in the plasma medicine community. While enabling to choose the most promising source for a certain biomedical application, comparison of the different sources with a focus on their effect on biological targets is rather challenging. To allow for better comparison of various sources, the recent European COST action MP1101 was used to design the COST reference microplasma jet. Cysteine is a promising candidate investigate the impact of plasma from various sources on a standardized biological molecule, which is especially relevant for the investigations on a molecular level after plasma treatment. The simple structure of cysteine allows for a more in-depth analysis of each chemical group after plasma treatment and enables a comparison between different plasma sources and treatment parameters on each chemical group. The model itself has already been successfully established using a dielectric barrier discharge. Here, additional plasma sources are compared by the means of their impact on cysteine samples, showing e.g. the influence of feed-gas variations by adding oxygen or nitrogen admixture This work was supported by the German Research Foundation (DFG) with the packet grant PAK816 (PlaCID).

  2. Shunting arc plasma source for pure carbon ion beam.

    Science.gov (United States)

    Koguchi, H; Sakakita, H; Kiyama, S; Shimada, T; Sato, Y; Hirano, Y

    2012-02-01

    A plasma source is developed using a coaxial shunting arc plasma gun to extract a pure carbon ion beam. The pure carbon ion beam is a new type of deposition system for diamond and other carbon materials. Our plasma device generates pure carbon plasma from solid-state carbon material without using a hydrocarbon gas such as methane gas, and the plasma does not contain any hydrogen. The ion saturation current of the discharge measured by a double probe is about 0.2 mA∕mm(2) at the peak of the pulse.

  3. Shunting arc plasma source for pure carbon ion beama)

    Science.gov (United States)

    Koguchi, H.; Sakakita, H.; Kiyama, S.; Shimada, T.; Sato, Y.; Hirano, Y.

    2012-02-01

    A plasma source is developed using a coaxial shunting arc plasma gun to extract a pure carbon ion beam. The pure carbon ion beam is a new type of deposition system for diamond and other carbon materials. Our plasma device generates pure carbon plasma from solid-state carbon material without using a hydrocarbon gas such as methane gas, and the plasma does not contain any hydrogen. The ion saturation current of the discharge measured by a double probe is about 0.2 mA/mm2 at the peak of the pulse.

  4. Catheterized plasma X-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Derzon, Mark S.; Robinson, Alex; Galambos, Paul C.

    2017-06-20

    A radiation generator useful for medical applications, among others, is provided. The radiation generator includes a catheter; a plasma discharge chamber situated within a terminal portion of the catheter, a cathode and an anode positioned within the plasma discharge chamber and separated by a gap, and a high-voltage transmission line extensive through the interior of the catheter and terminating on the cathode and anode so as to deliver, in operation, one or more voltage pulses across the gap.

  5. Physical limitations in ferromagnetic inductively coupled plasma sources

    CERN Document Server

    Bliokh, Yury P; Slutsker, Yakov Z

    2012-01-01

    The Ferromagnetic Inductively Coupled Plasma (FICP) source, which is a version of the common inductively coupled plasma sources, has a number of well known advantages such as high efficiency, high level of ionization, low minimal gas pressure, very low required driver frequency, and even a possibility to be driven by single current pulses. We present an experimental study of such an FICP source which showed that above a certain value of the driving pulse power the properties of this device changed rather drastically. Namely, the plasma became non-stationary and non-uniform contrary to the stationary and uniform plasmas typical for this kind of plasma sources. In this case the plasma appeared as a narrow dense spike which was short compared to the driving pulse. The local plasma density could exceed the neutral atoms density by a few orders of magnitude. When that happened, the afterglow plasma decay time after the end of the pulse was long compared to an ordinary case with no plasma spike. Experiments were pe...

  6. VUV Emission of Microwave Driven Argon Plasma Source

    Science.gov (United States)

    Henriques, Julio; Espinho, Susana; Felizardo, Edgar; Tatarova, Elena; Dias, Francisco; Ferreira, Carlos

    2013-09-01

    An experimental and kinetic modeling investigation of a low-pressure (0.1-1.2 mbar), surface wave (2.45 GHz) induced Ar plasma as a source vacuum ultraviolet (VUV) light is presented, using visible and VUV optical spectroscopy. The electron density and the relative VUV emission intensities of excited Ar atoms (at 104.8 nm and 106.6 nm) and ions (at 92.0 nm and 93.2 nm) were determined as a function of the microwave power and pressure. The experimental results were analyzed using a 2D self-consistent theoretical model based on a set of coupled equations including the electron Boltzmann equation, the rate balance equations for the most important electronic excited species and for charged particles, the gas thermal balance equation, and the wave electrodynamics. The principal collisional and radiative processes for neutral Ar(3p54s) and Ar(3p54p) and ionized Ar(3s3p6 2S1/2) levels are accounted for. Model predictions are in good agreement with the experimental measurements. This study was funded by the Foundation for Science and Technology, Portuguese Ministry of Education and Science, under the research contract PTDC/FIS/108411/2008.

  7. Counter-facing plasma guns for efficient extreme ultra-violet plasma light source

    Science.gov (United States)

    Kuroda, Yusuke; Yamamoto, Akiko; Kuwabara, Hajime; Nakajima, Mitsuo; Kawamura, Tohru; Horioka, Kazuhiko

    2013-11-01

    A plasma focus system composed of a pair of counter-facing coaxial guns was proposed as a long-pulse and/or repetitive high energy density plasma source. We applied Li as the source of plasma for improvement of the conversion efficiency, the spectral purity, and the repetition capability. For operation of the system with ideal counter-facing plasma focus mode, we changed the system from simple coaxial geometry to a multi-channel configuration. We applied a laser trigger to make synchronous multi-channel discharges with low jitter. The results indicated that the configuration is promising to make a high energy density plasma with high spectral efficiency.

  8. Developing the Science and Technology for the Material Plasma Exposure eXperiment (MPEX)

    Science.gov (United States)

    Rapp, Juergen; Biewer, Theodore; Bigelow, Timothy; Caughman, John; Goulding, Richard; Lumsdaine, Arnold; MPEX Team Team

    2016-10-01

    The Material Plasma Exposure eXperiment (MPEX) is a device planned to address scientific and technological gaps for the development of viable plasma facing components for fusion reactor conditions (FNSF, DEMO). MPEX is designed to deliver those plasma conditions with a novel Radio Frequency plasma source able to produce high density plasmas and heat electron and ions separately with Electron Bernstein Wave (EBW) heating and Ion Cyclotron Resonance Heating (ICRH) with a total installed power of 800 kW. The science and technology for this source system is currently being tested on Proto-MPEX. This is a linear device utilizing 12 water-cooled copper coils able to achieve peak magnetic fields of 1.6T. The currently total installed heating power (for helicon, EBW and ICRH) is 330kW. An overview of the status of this development program is given with an outlook to the next steps.

  9. Ferroelectric Plasma Source for Heavy Ion Beam Charge Neutralization

    CERN Document Server

    Efthimion, Philip; Gilson, Erik P; Grisham, Larry; Logan, B G; Waldron, William; Yu, Simon

    2005-01-01

    Plasmas are employed as a medium for charge neutralizing heavy ion beams to allow them to focus to a small spot size. Calculations suggest that plasma at a density of 1-100 times the ion beam density and at a length ~ 0.1-1 m would be suitable. To produce 1 meter plasma, large-volume plasma sources based upon ferroelectric ceramics are being considered. These sources have the advantage of being able to increase the length of the plasma and operate at low neutral pressures. The source will utilize the ferroelectric ceramic BaTiO3 to form metal plasma. The drift tube inner surface of the Neutralized Drift Compression Experiment (NDCX) will be covered with ceramic. High voltage (~ 1-5 kV) is applied between the drift tube and the front surface of the ceramic by placing a wire grid on the front surface. A prototype ferroelectric source 20 cm long produced plasma densities ~ 5x1011 cm-3. The source was integrated into the experiment and successfully charge neutralized the K ion beam. Presently, the 1 meter source ...

  10. Design and Construction of a Microwave Plasma Ion Source

    CERN Document Server

    Çınar, Kamil

    2011-01-01

    This thesis is about the designing and constructing a microwave ion source. The ions are generated in a thermal and dense hydrogen plasma by microwave induction. The plasma is generated by using a microwave source with a frequency of 2.45 GHz and a power of 700 W. The generated microwave is pulsing with a frequency of 50 Hz. The designed and constructed microwave system generates hydrogen plasma in a pyrex plasma chamber. Moreover, an ion extraction unit is designed and constructed in order to extract the ions from the generated hydrogen plasma. The ion beam extraction is achieved and ion currents are measured. The plasma parameters are determined by a double Langmuir probe and the ion current is measured by a Faraday cup. The designed ion extraction unit is simulated by using the dimensions of the designed and constructed ion extraction unit in order to trace out the trajectories of the extracted ions.

  11. Modeling of low pressure plasma sources for microelectronics fabrication

    Science.gov (United States)

    Agarwal, Ankur; Bera, Kallol; Kenney, Jason; Likhanskii, Alexandre; Rauf, Shahid

    2017-10-01

    Chemically reactive plasmas operating in the 1 mTorr–10 Torr pressure range are widely used for thin film processing in the semiconductor industry. Plasma modeling has come to play an important role in the design of these plasma processing systems. A number of 3-dimensional (3D) fluid and hybrid plasma modeling examples are used to illustrate the role of computational investigations in design of plasma processing hardware for applications such as ion implantation, deposition, and etching. A model for a rectangular inductively coupled plasma (ICP) source is described, which is employed as an ion source for ion implantation. It is shown that gas pressure strongly influences ion flux uniformity, which is determined by the balance between the location of plasma production and diffusion. The effect of chamber dimensions on plasma uniformity in a rectangular capacitively coupled plasma (CCP) is examined using an electromagnetic plasma model. Due to high pressure and small gap in this system, plasma uniformity is found to be primarily determined by the electric field profile in the sheath/pre-sheath region. A 3D model is utilized to investigate the confinement properties of a mesh in a cylindrical CCP. Results highlight the role of hole topology and size on the formation of localized hot-spots. A 3D electromagnetic plasma model for a cylindrical ICP is used to study inductive versus capacitive power coupling and how placement of ground return wires influences it. Finally, a 3D hybrid plasma model for an electron beam generated magnetized plasma is used to understand the role of reactor geometry on plasma uniformity in the presence of E  ×  B drift.

  12. Laser Plasma Particle Accelerators: Large Fields for Smaller Facility Sources

    Energy Technology Data Exchange (ETDEWEB)

    Geddes, Cameron G.R.; Cormier-Michel, Estelle; Esarey, Eric H.; Schroeder, Carl B.; Vay, Jean-Luc; Leemans, Wim P.; Bruhwiler, David L.; Cary, John R.; Cowan, Ben; Durant, Marc; Hamill, Paul; Messmer, Peter; Mullowney, Paul; Nieter, Chet; Paul, Kevin; Shasharina, Svetlana; Veitzer, Seth; Weber, Gunther; Rubel, Oliver; Ushizima, Daniela; Bethel, Wes; Wu, John

    2009-03-20

    Compared to conventional particle accelerators, plasmas can sustain accelerating fields that are thousands of times higher. To exploit this ability, massively parallel SciDAC particle simulations provide physical insight into the development of next-generation accelerators that use laser-driven plasma waves. These plasma-based accelerators offer a path to more compact, ultra-fast particle and radiation sources for probing the subatomic world, for studying new materials and new technologies, and for medical applications.

  13. Laser-Produced Plasmas and Radiation Sources.

    Science.gov (United States)

    1980-01-31

    Vlases, H. Rutkowski, A. Hertzberg, A. Hoffman, L. Steinhauer, J. Dawson, D.R. Cohn, W. Halverson, B. Lax, J.D. Daugherty, J.E. Eninger , E.R. Pugh, T.K...Meeting, Albuquerque (October 1974). J.D. Daugherty, J.E. Eninger , D.R. Cohn, and W. Halverson, "Scaling of Laser Heated Plasmas Confined in Long Solenoids...Cohn, H.E. Eninger , W. Halverson, and D.J. Rose, "Stress, Dissipation, and Neutronics Constraints on ’fagnets for Laser-Solenoid Reactors," APS Plasma

  14. Matching network for RF plasma source

    Science.gov (United States)

    Pickard, Daniel S.; Leung, Ka-Ngo

    2007-11-20

    A compact matching network couples an RF power supply to an RF antenna in a plasma generator. The simple and compact impedance matching network matches the plasma load to the impedance of a coaxial transmission line and the output impedance of an RF amplifier at radio frequencies. The matching network is formed of a resonantly tuned circuit formed of a variable capacitor and an inductor in a series resonance configuration, and a ferrite core transformer coupled to the resonantly tuned circuit. This matching network is compact enough to fit in existing compact focused ion beam systems.

  15. Studies on plasma production in a large volume system using multiple compact ECR plasma sources

    Science.gov (United States)

    Tarey, R. D.; Ganguli, A.; Sahu, D.; Narayanan, R.; Arora, N.

    2017-01-01

    This paper presents a scheme for large volume plasma production using multiple highly portable compact ECR plasma sources (CEPS) (Ganguli et al 2016 Plasma Source Sci. Technol. 25 025026). The large volume plasma system (LVPS) described in the paper is a scalable, cylindrical vessel of diameter  ≈1 m, consisting of source and spacer sections with multiple CEPS mounted symmetrically on the periphery of the source sections. Scaling is achieved by altering the number of source sections/the number of sources in a source section or changing the number of spacer sections for adjusting the spacing between the source sections. A series of plasma characterization experiments using argon gas were conducted on the LVPS under different configurations of CEPS, source and spacer sections, for an operating pressure in the range 0.5-20 mTorr, and a microwave power level in the range 400-500 W per source. Using Langmuir probes (LP), it was possible to show that the plasma density (~1  -  2  ×  1011 cm-3) remains fairly uniform inside the system and decreases marginally close to the chamber wall, and this uniformity increases with an increase in the number of sources. It was seen that a warm electron population (60-80 eV) is always present and is about 0.1% of the bulk plasma density. The mechanism of plasma production is discussed in light of the results obtained for a single CEPS (Ganguli et al 2016 Plasma Source Sci. Technol. 25 025026).

  16. Rare-earth plasma light source for VUV applications.

    Science.gov (United States)

    O'Sullivan, G; Carroll, P K; McLlrath, T J; Ginter, M L

    1981-09-01

    A compact versatile light source for producing VUV radiation from laser produced plasmas is described. Measurements of the spectral irradiance from CO(2) laser-produced plasmas on targets of gadolinium and ytterbium in the 115-220-nm range are given, and a comparison is made with analogous results obtained using a ruby laser.

  17. Modelling the plasma plume of an assist source in PIAD

    Science.gov (United States)

    Wauer, Jochen; Harhausen, Jens; Foest, Rüdiger; Loffhagen, Detlef

    2016-09-01

    Plasma ion assisted deposition (PIAD) is a technique commonly used to produce high-precision optical interference coatings. Knowledge regarding plasma properties is most often limited to dedicated scenarios without film deposition. Approaches have been made to gather information on the process plasma in situ to detect drifts which are suspected to cause limits in repeatability of resulting layer properties. Present efforts focus on radiance monitoring of the plasma plume of an Advanced Plasma Source (APSpro, Bühler) by optical emission spectroscopy to provide the basis for an advanced plasma control. In this contribution modelling results of the plume region are presented to interpret these experimental data. In the framework of the collisional radiative model used, 15 excited neutral argon states in the plasma are considered. Results of the species densities show good consistency with the measured optical emission of various argon 2 p - 1 s transitions. This work was funded by BMBF under grant 13N13213.

  18. A Plasma Ion Source for ISOLTRAP

    CERN Document Server

    Skov, Thomas Guldager

    2016-01-01

    In this report, my work testing the new Penning ion source as a summer student at ISOLTRAP is described. The project was composed of three stages: (1) Setting up a test laboratory in building 275, (2) characterizing the ion source, and (3) implementing and testing the source in the ISOLTRAP setup. After setting up the test laboratory, the ion source was tested in a constant pressure environment with produced ion currents in the range of nA . An extensive scan of the source ion current versus operating parameters (pressure, voltage) was performed. A setup with pulsed gas flow was also tested, allowing a reduction of the gas load on the vacuum system. The behavior of the ion source together with the ISOLTRAP setup was also investigated, allowing to understand current limitations and future directions of improvement.

  19. Advances and Challenges in Computational Plasma Science

    Energy Technology Data Exchange (ETDEWEB)

    W.M. Tang; V.S. Chan

    2005-01-03

    Scientific simulation, which provides a natural bridge between theory and experiment, is an essential tool for understanding complex plasma behavior. Recent advances in simulations of magnetically-confined plasmas are reviewed in this paper with illustrative examples chosen from associated research areas such as microturbulence, magnetohydrodynamics, and other topics. Progress has been stimulated in particular by the exponential growth of computer speed along with significant improvements in computer technology.

  20. A DOE/Fusion Energy Sciences Research/Education Program at PVAMU Study of Rotamak Plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Tian-Sen [Prairie View A& M Univ., Prairie View, TX (United States); Saganti, Premkumar [Prairie View A& M Univ., Prairie View, TX (United States)

    2017-02-17

    During recent years (2004-2015), with DOE support, the PVAMU plasma research group accomplished new instrumentation development, conducted several new plasma experiments, and is currently poised to advance with standing-wave microwave plasma propulsion research. On the instrumentation development, the research group completed: (i) building a new plasma chamber with metal CF flanges, (ii) setting up of a 6kW/2450MHz microwave input system as an additional plasma heating source at our rotamak plasma facility, (iii) installation of one programmatic Kepco ATE 6-100DMG fast DC current supply system used in rotamak plasma shape control experiment, built a new microwave, standing-wave experiment chamber and (iv) established a new plasma lab with field reversal configuration capability utilizing 1MHz/200kW RF (radio frequency) wave generator. Some of the new experiments conducted in this period also include: (i) assessment of improved magnetic reconnection at field-reversed configuration (FRC) plasma, (ii) introduction of microwave heating experiments, and (iii) suppression of n = 1 tilt instability by one coil with a smaller current added inside the rotamak’s central pipe. These experiments led to publications in Physical Review Letters, Reviews of Scientific Instruments, Division of Plasma Physics (DPP) of American Physical Society (APS) Reports, Physics of Plasmas Controlled Fusion, and Physics of Plasmas (between 2004 and 2015). With these new improvements and advancements, we also initiated and accomplished design and fabrication of a plasma propulsion system. Currently, we are assembling a plasma propulsion experimental system that includes a 5kW helicon plasma source, a 25 cm diameter plasma heating chamber with 1MHz/200kW RF power rotating magnetic field, and a 60 cm diameter plasma exhaust chamber, and expect to achieve a plasma mass flow of 0.1g/s with 60km/s ejection. We anticipate several propulsion applications in near future as we advance our capabilities

  1. Multicapillary cathode controlled by a ferroelectric plasma source

    Science.gov (United States)

    Gleizer, J. Z.; Hadas, Y.; Krasik, Ya. E.

    2008-06-01

    We present results of high-current microsecond and sub-microsecond duration electron beam generation in a ~200 kV diode with a multicapillary dielectric cathode (MCDC) assisted by a ferroelectric plasma source (FPS). Electron beam current densities are achieved up to 40 A/cm2. It was shown that the operation of the MCDC is determined by the parameters of the plasma flow generated by the FPS. Also, it was found that the high resistivity of the plasma produced inside the capillaries allows effective de-coupling of individual capillary plasma discharges which results in uniform electron beam generation.

  2. Characteristics of Cylindrical Microwave Plasma Source at Low Pressure

    Science.gov (United States)

    Park, Seungil; Youn, S.; Kim, S. B.; Yoo, S. J.

    2016-10-01

    A microwave plasma source with a cylindrical resonance cavity has been proposed to generate the plasma at low pressure. This plasma source consists of magnetron, waveguide, antenna, and cavity. The microwave generating device is a commercial magnetron with 1 kW output power at the frequency of 2.45 GHz. The microwave is transmitted through the rectangular waveguide with the whistle shape, and coupled to the cavity by the slot antenna. The resonant mode of the cylindrical cavity is the TE111 mode. The operating pressure is between 0.1 Torr and 0.3 Torr with the Argon and nitrogen gas. The electron temperature and electron number density of argon plasma were measured with the optical emission spectroscopy measurement. And Ar1s5 metastable density was measured using tunable diode laser absorption spectroscopy (TDLAS). The plasma diagnostic results of a cylindrical microwave plasma source would be described in this study. This work was supported by R&D Program of ``Plasma Advanced Technology for Agriculture and Food (Plasma Farming)'' through the National Fusion Research Institute of Korea (NFRI) funded by the Government funds.

  3. Alternative modeling methods for plasma-based Rf ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Veitzer, Seth A., E-mail: veitzer@txcorp.com; Kundrapu, Madhusudhan, E-mail: madhusnk@txcorp.com; Stoltz, Peter H., E-mail: phstoltz@txcorp.com; Beckwith, Kristian R. C., E-mail: beckwith@txcorp.com [Tech-X Corporation, Boulder, Colorado 80303 (United States)

    2016-02-15

    Rf-driven ion sources for accelerators and many industrial applications benefit from detailed numerical modeling and simulation of plasma characteristics. For instance, modeling of the Spallation Neutron Source (SNS) internal antenna H{sup −} source has indicated that a large plasma velocity is induced near bends in the antenna where structural failures are often observed. This could lead to improved designs and ion source performance based on simulation and modeling. However, there are significant separations of time and spatial scales inherent to Rf-driven plasma ion sources, which makes it difficult to model ion sources with explicit, kinetic Particle-In-Cell (PIC) simulation codes. In particular, if both electron and ion motions are to be explicitly modeled, then the simulation time step must be very small, and total simulation times must be large enough to capture the evolution of the plasma ions, as well as extending over many Rf periods. Additional physics processes such as plasma chemistry and surface effects such as secondary electron emission increase the computational requirements in such a way that even fully parallel explicit PIC models cannot be used. One alternative method is to develop fluid-based codes coupled with electromagnetics in order to model ion sources. Time-domain fluid models can simulate plasma evolution, plasma chemistry, and surface physics models with reasonable computational resources by not explicitly resolving electron motions, which thereby leads to an increase in the time step. This is achieved by solving fluid motions coupled with electromagnetics using reduced-physics models, such as single-temperature magnetohydrodynamics (MHD), extended, gas dynamic, and Hall MHD, and two-fluid MHD models. We show recent results on modeling the internal antenna H{sup −} ion source for the SNS at Oak Ridge National Laboratory using the fluid plasma modeling code USim. We compare demonstrate plasma temperature equilibration in two

  4. Alternative modeling methods for plasma-based Rf ion sources

    Science.gov (United States)

    Veitzer, Seth A.; Kundrapu, Madhusudhan; Stoltz, Peter H.; Beckwith, Kristian R. C.

    2016-02-01

    Rf-driven ion sources for accelerators and many industrial applications benefit from detailed numerical modeling and simulation of plasma characteristics. For instance, modeling of the Spallation Neutron Source (SNS) internal antenna H- source has indicated that a large plasma velocity is induced near bends in the antenna where structural failures are often observed. This could lead to improved designs and ion source performance based on simulation and modeling. However, there are significant separations of time and spatial scales inherent to Rf-driven plasma ion sources, which makes it difficult to model ion sources with explicit, kinetic Particle-In-Cell (PIC) simulation codes. In particular, if both electron and ion motions are to be explicitly modeled, then the simulation time step must be very small, and total simulation times must be large enough to capture the evolution of the plasma ions, as well as extending over many Rf periods. Additional physics processes such as plasma chemistry and surface effects such as secondary electron emission increase the computational requirements in such a way that even fully parallel explicit PIC models cannot be used. One alternative method is to develop fluid-based codes coupled with electromagnetics in order to model ion sources. Time-domain fluid models can simulate plasma evolution, plasma chemistry, and surface physics models with reasonable computational resources by not explicitly resolving electron motions, which thereby leads to an increase in the time step. This is achieved by solving fluid motions coupled with electromagnetics using reduced-physics models, such as single-temperature magnetohydrodynamics (MHD), extended, gas dynamic, and Hall MHD, and two-fluid MHD models. We show recent results on modeling the internal antenna H- ion source for the SNS at Oak Ridge National Laboratory using the fluid plasma modeling code USim. We compare demonstrate plasma temperature equilibration in two-temperature MHD models

  5. Inertial Electrostatic Confinement (IEC) Fusion using Helicon Injected Plasma Source

    Science.gov (United States)

    Miley, George; Ahern, Drew; Bowman, Jaerd

    2016-10-01

    The use of an external plasma source with the IEC has the advantage that the background pressure in the IEC chamber can be low. This then enables a deep potential well formation for ion confinement. Also unit efficiency is increase due to minimization of ion losses through charge exchange. This technique is under study experimentally for use in a plasma jet propulsion unit and as an IEC type neutron source. Current work has studied the effect of locating the IEC grids off-center in the vacuum chamber, near the plasma entrance from the Helicon. With double grids, the relative potentials employed are also key factors in device performance. Electron emitters are added for space charge neutralization in the case of plasma jet propulsion. Plasma simulations are used to supplement the experiments. Specifically, the electric field and the magnetic field effects on energetic ion trajectories are examined for varying configurations. Funding by NASA, Air Force Research Lab and NPL Associates.

  6. Combined Gas-Liquid Plasma Source for Nanoparticle Synthesis

    Science.gov (United States)

    Burakov, V. S.; Kiris, V. V.; Nevar, A. A.; Nedelko, M. I.; Tarasenko, N. V.

    2016-09-01

    A gas-liquid plasma source for the synthesis of colloidal nanoparticles by spark erosion of the electrode material was developed and allowed the particle synthesis regime to be varied over a wide range. The source parameters were analyzed in detail for the electrical discharge conditions in water. The temperature, particle concentration, and pressure in the discharge plasma were estimated based on spectroscopic analysis of the plasma. It was found that the plasma parameters did not change signifi cantly if the condenser capacitance was increased from 5 to 20 nF. Purging the electrode gap with argon reduced substantially the pressure and particle concentration. Signifi cant amounts of water decomposition products in addition to electrode elements were found in the plasma in all discharge regimes. This favored the synthesis of oxide nanoparticles.

  7. Educational Outreach at the MIT Plasma Science and Fusion Center

    Science.gov (United States)

    Rivenberg, Paul; Thomas, Paul

    2006-10-01

    At the MIT PSFC, student and staff volunteers work together to increase the public's knowledge of fusion science and plasma technology. Seeking to generate excitement in young people about science and engineering, the PSFC hosts a number of educational outreach activities throughout the year, including Middle and High School Outreach Days. The PSFC also has an in-school science demonstration program on the theme of magnetism. The Mr. Magnet Program, headed by Mr. Paul Thomas, has been bringing lively demonstrations on magnetism into local elementary and middle schools for 15 years. This year Mr. Magnet presented the program to nearly 30,000 students at over 67 schools and other events, reaching kindergartners through college freshmen. In addition to his program on magnetism, he is offering an interactive lecture about plasma to high schools. The "Traveling Plasma Lab" encourages students to learn more about plasma science while having fun investigating plasma properties using actual laboratory techniques and equipment. Beyond the classroom, Paul Thomas has provided technical training for Boston Museum of Science staff in preparation for the opening of a Star Wars exhibit. His hands-on demos have also been filmed by the History Channel for a one-hour program about Magnetism, which aired in June 2006.

  8. 77 FR 6463 - Revisions to Labeling Requirements for Blood and Blood Components, Including Source Plasma...

    Science.gov (United States)

    2012-02-08

    ... Requirements for Blood and Blood Components, Including Source Plasma; Correction AGENCY: Food and Drug... Blood Components, Including Source Plasma,'' which provided incorrect publication information...

  9. Development of a long-slot microwave plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Kuwata, Y., E-mail: euo1304@mail4.doshisha.ac.jp; Kasuya, T.; Miyamoto, N.; Wada, M. [Graduate School of Science and Engineering, Doshisha University, Kyotanabe, Kyoto 610-0321 (Japan)

    2016-02-15

    A 20 cm long 10 cm wide microwave plasma source was realized by inserting two 20 cm long 1.5 mm diameter rod antennas into the plasma. Plasma luminous distributions around the antennas were changed by magnetic field arrangement created by permanent magnets attached to the source. The distributions appeared homogeneous in one direction along the antenna when the spacing between the antenna and the source wall was 7.5 mm for the input microwave frequency of 2.45 GHz. Plasma density and temperature at a plane 20 cm downstream from the microwave shield were measured by a Langmuir probe array at 150 W microwave power input. The measured electron density and temperature varied over space from 3.0 × 10{sup 9} cm{sup −3} to 5.8 × 10{sup 9} cm{sup −3}, and from 1.1 eV to 2.1 eV, respectively.

  10. Multicomponent Consideration of Electron Fraction of ECR Source Plasma

    CERN Document Server

    Shirkov, G D

    1999-01-01

    The development of physical model and mathematical simulation methods of electron and ion accumulation and production in the ECR ion source is presented. New equations represent electrons in the ECR plasma as a multicomponent media. In the result any kind of experimental or analytical electron distribution function can be approximated with a series of Maxwellian distributions with different temperatures and partial weights. Main positive plasma potential is introduced into consideration in addition to the negative potential dip for highly charged ion confinement. This potential regulates the loss rate of primary cold electrons from the plasma volume and completes the total picture of ECR plasma behavior. The first test of new model and code with recent experimental data of RIKEN 18 GHz ECR source has shown some new opportunities for investigators to study the ECR ion sources.

  11. Industrial application of electron sources with plasma emitters

    CERN Document Server

    Belyuk, S I; Rempe, N G

    2001-01-01

    Paper contains a description, operation, design and parameters of electron sources with plasma emitters. One presents examples of application of these sources as part of automated electron-beam welding lines. Paper describes application of such sources for electron-beam deposition of composite powders. Electron-beam deposition is used to rebuild worn out part and to increase strength of new parts of machines and tools. Paper presents some examples of rebuilding part and the advantages gained in this case

  12. Candidate plasma-facing materials for EUV lithography source components

    Science.gov (United States)

    Hassanein, Ahmed; Burtseva, Tatiana; Brooks, Jeff N.; Konkashbaev, Isak K.; Rice, Bryan J.

    2003-06-01

    Material selection and lifetime issues for extreme ultraviolet (EUV) lithography are of critical importance to the success of this technology for commercial applications. This paper reviews current trends in production and use of plasma-facing electrodes, insulators, and wall materials for EUV type sources. Ideal candidate materials should be able to: withstand high thermal shock from the short pulsed plasma; withstand high thermal loads without structural failure; reduce debris generation during discharge; and be machined accurately. We reviewed the literature on current and proposed fusion plasma-facing materials as well as current experience with plasma gun and other simulation devices. Both fusion and EUV source materials involve issues of surface erosion by particle sputtering and heat-induced evaporation/melting. These materials are either bare structural materials or surface coatings. EUV materials can be divided into four categories: wall, electrode, optical, and insulator materials. For electric discharge sources, all four types are required, whereas laser-produced plasma EUV sources do not require electrode and insulator materials. Several types of candidate alloy and other materials and methods of manufacture are recommended for each component of EUV lithography light sources.

  13. Surface-wave plasma source with magnetic multicusp fields; Multicusp jiba tojikome hyomenha plasma gen

    Energy Technology Data Exchange (ETDEWEB)

    Tsuda, M.; Ono, K.; Tsuchihashi, M.; Hanazaki, M.; Komemura, T. [Mitsubishi Electric Corp., Tokyo (Japan)

    1998-11-01

    A new-type microwave plasma source has been developed for materials processing. The plasma reactor employed a launcher of azimuthally symmetric surface waves at a frequency of 2.45 GHz and also magnetic multicusp fields around the reactor chamber walls. This configuration yielded high-density (Ne {>=} 10{sup 11}cm{sup -3}) plasmas sustained by surface waves even at low gas pressures below 10 m Torr, following easy plasma ignition by electron cyclotron resonance (ECR) discharges. Electrical and optical diagnostics were made to obtain the plasma properties in Ar. It was shown that a transition from ECR excited to surface-wave excited plasmas occurs under conditions where the plasma electron density exceeds a critical value of Ne-1 times 10{sup 11}cm{sup -3}. 21 refs., 14 figs.

  14. A highly reliable trigger for vacuum ARC plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Bernardet, H.; Godechot, X.; Jarjat, F. [SODERN, Limeil-Brevannes (France)

    1996-08-01

    The authors have developed a reliable electrical trigger and its associated circuitry to fire vacuum arc plasma or ion source. They tested different embodiments of the trigger device in order to get a highly reliable one, which is able to perform more than 1.2 x 10{sup 6} shots at 60 A and 6.5 ps pulse length. The evolution of the ion current emitted has been recorded as a function of the number of shots. They have also investigated in which direction the plasma jet is emitted : axially or radially. This device can be used to fire a vacuum arc plasma or ion source by plasma injection. It has obvious advantage to be placed outside the cathode and therefore would ease maintenance of vacuum arc devices.

  15. Are Spicules the Primary Source of Hot Coronal Plasma?

    Science.gov (United States)

    Klimchuk, James A.

    2011-01-01

    The recent discovery of Type II spicules has generated considerable excitement. It has even been suggested that these ejections can account for a majority of the hot plasma observed in the corona, thus obviating the need for "coronal" heating. If this is the case, however, then there should be observational consequences. We have begun to examine some of these consequences and find reason to question the idea that spicules are the primary source of hot coronal plasma.

  16. Photoionization of an aluminum plasma by a tantalum X source

    Science.gov (United States)

    Renaudin, Patrick; Back, Christina A.; Chenais-Popovics, Claude; Audebert, Patrick; Geindre, Jean-Paul; Gauthier, Jean-Claude

    1991-05-01

    Photoionization of a helium like aliminum plasma is carried out by an external x-source. The laser beam used corresponds to the 3d to 4F transition level of tantalum. The experimental spectrum of tantalum is shown superimposed over the emission spectrum of aluminum on diagrammatic form. Good correspondence is seen between the 3d to 4F emissions of tantalum and helium like aluminum. Plasma pumping is obtained by exposure of a tantalum target to laser rays.

  17. Simple filtered repetitively pulsed vacuum arc plasma source

    Science.gov (United States)

    Chekh, Yu.; Zhirkov, I. S.; Delplancke-Ogletree, M. P.

    2010-02-01

    A very simple design of cathodic filtered vacuum arc plasma source is proposed. The source without filter has only four components and none of them require precise machining. The source operates in a repetitively pulsed regime, and for laboratory experiments it can be used without water cooling. Despite the simple construction, the source provides high ion current at the filter outlet reaching 2.5% of 400 A arc current, revealing stable operation in a wide pressure range from high vacuum to oxygen pressure up to more than 10-2 mbar. There is no need in complicated power supply system for this plasma source, only one power supply can be used to ignite the arc, to provide the current for the arc itself, to generate the magnetic field in the filter, and provide its positive electric biasing without any additional high power resistance.

  18. e+e- Plasma Photon Source

    Energy Technology Data Exchange (ETDEWEB)

    Hartouni, Ed P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-12-06

    This note addresses the idea of a photon source that is based on an e+e- plasma created by co-propagating beams of e+ and e-. The plasma has a well-defined temperature, and the thermal distribution of the charged particles is used to average over the relative velocity cross section multiplied by the relative velocity. Two relevant cross sections are the direct “free-free” annihilation of e+e- pairs in the plasma, and the radiative recombination of e+e- pairs into positronium (Ps) which subsequently undergoes annihilation.

  19. Open Genetic Code: on open source in the life sciences

    NARCIS (Netherlands)

    Deibel, E.

    2014-01-01

    The introduction of open source in the life sciences is increasingly being suggested as an alternative to patenting. This is an alternative, however, that takes its shape at the intersection of the life sciences and informatics. Numerous examples can be identified wherein open source in the life

  20. 21 CFR 640.64 - Collection of blood for Source Plasma.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Collection of blood for Source Plasma. 640.64... (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.64 Collection of blood for Source Plasma. (a) Supervision. All blood for the collection of Source Plasma shall...

  1. Counter-facing plasma guns for efficient extreme ultra-violet plasma light source

    Directory of Open Access Journals (Sweden)

    Kuroda Yusuke

    2013-11-01

    Full Text Available A plasma focus system composed of a pair of counter-facing coaxial guns was proposed as a long-pulse and/or repetitive high energy density plasma source. We applied Li as the source of plasma for improvement of the conversion efficiency, the spectral purity, and the repetition capability. For operation of the system with ideal counter-facing plasma focus mode, we changed the system from simple coaxial geometry to a multi-channel configuration. We applied a laser trigger to make synchronous multi-channel discharges with low jitter. The results indicated that the configuration is promising to make a high energy density plasma with high spectral efficiency.

  2. The Future of Boundary Plasma and Material Science

    Science.gov (United States)

    Whyte, Dennis

    2012-03-01

    The boundary of magnetic confinement devices, from the pedestal through to the surrounding surfaces, encompasses an enormous range of plasma and material physics, and their integrated coupling. It is becoming clear that due to fundamental limits of plasma stability and material response the boundary will largely define the viability of an MFE reactor. However we face an enormous knowledge deficit in stepping from present devices and ITER towards a demonstration power plant. We outline the future of boundary research required to address this deficit. The boundary should be considered a multi-scale system of coupled plasma and material science regulated through the non-linear interface of the sheath. Measurement, theory and modeling across these scales are assessed. Dimensionless parameters, often used to organized core plasma transport on similarity arguments, can be extended to the boundary plasma, plasma-surface interactions and material response. This methodology suggests an intriguing way forward to prescribe and understand the boundary issues of an eventual reactor in intermediate devices. A particularly critical issue is that the physical chemistry of the material, which is mostly determined by the material temperature, has been too neglected; pointing to the requirement for boundary plasma experiments at appropriate material temperatures. Finally the boundary plasma requirements for quiescent heat exhaust and control of transient events, such as ELMs, will be examined.

  3. Neutron Source from Laser Plasma Acceleration

    Science.gov (United States)

    Jiao, Xuejing; Shaw, Joseph; McCary, Eddie; Downer, Mike; Hegelich, Bjorn

    2016-10-01

    Laser driven electron beams and ion beams were utilized to produce neutron sources via different mechanism. On the Texas Petawatt laser, deuterized plastic, gold and DLC foil targets of varying thickness were shot with 150 J , 150 fs laser pulses at a peak intensity of 2 ×1021W /cm2 . Ions were accelerated by either target normal sheath acceleration or Breakout Afterburner acceleration. Neutrons were produced via the 9Be(d,n) and 9Be(p,n) reactions when accelerated ions impinged on a Beryllium converter as well as by deuteron breakup reactions. We observed 2 ×1010 neutron per shot in average, corresponding to 5 ×1018n /s . The efficiencies for different targets are comparable. In another experiment, 38fs , 0.3 J UT3 laser pulse interacted with mixed gas target. Electrons with energy 40MeV were produced via laser wakefield acceleration. Neutron flux of 2 ×106 per shot was generated through bremsstrahlung and subsequent photoneutron reactions on a Copper converter.

  4. Assistant Anode in a Cathodic Arc Plasma Source

    Institute of Scientific and Technical Information of China (English)

    张涛; Paul K. Chu; 张荟星; Ian G. Brown

    2001-01-01

    The performance and characteristics of a cathodic arc plasma source, consisting of a titanium cathode, an anode with and without a tungsten mesh, and a coil producing a focusing magnetic field between the anode and cathode,are investigated. The high transparency and large area of the mesh allow a high plasma flux to penetrate the anode from the cathodic arc. The mesh helps to decrease the arc resistance and the ignition voltage of the cathodic arc in the focusing magnetic field, and to increase the life of the source, which means that the source makes the cathodic arc easily and greatly stabilized during the operation when a focusing magnetic field exists in the source.

  5. Dense plasma focus (DPF) accelerated non radio isotopic radiological source

    Energy Technology Data Exchange (ETDEWEB)

    Rusnak, Brian; Tang, Vincent

    2017-01-31

    A non-radio-isotopic radiological source using a dense plasma focus (DPF) to produce an intense z-pinch plasma from a gas, such as helium, and which accelerates charged particles, such as generated from the gas or injected from an external source, into a target positioned along an acceleration axis and of a type known to emit ionizing radiation when impinged by the type of accelerated charged particles. In a preferred embodiment, helium gas is used to produce a DPF-accelerated He2+ ion beam to a beryllium target, to produce neutron emission having a similar energy spectrum as a radio-isotopic AmBe neutron source. Furthermore, multiple DPFs may be stacked to provide staged acceleration of charged particles for enhancing energy, tunability, and control of the source.

  6. Source diversity among journals cited in Science Times.

    Science.gov (United States)

    Kiernan, Vincent

    2016-02-01

    A content analysis of The New York Times' Science Times section from 1998 to 2012 found evidence of increased source diversity in use of scientific journals as news sources. Science Times increased the frequency at which it cited journals, the number of different journals that it cited, and the number of disciplines represented by cited journals. The results suggest that online availability of a wide array of scientific journals has changed sourcing behaviors.

  7. Mirror-field confined compact plasma source using permanent magnet for plasma processings

    Science.gov (United States)

    Goto, Tetsuya; Sato, Kei-ichiro; Yabuta, Yuki; Sugawa, Shigetoshi

    2016-12-01

    A mirror-field confined compact electron cyclotron resonance (ECR) plasma source using permanent magnets was developed, aiming for the realization of high-quality plasma processings where high-density reactive species are supplied to a substrate with minimizing the ion bombardment damages. The ECR position was located between a microwave transmissive window and a quartz limiter, and plasmas were transported from the ECR position to a midplane of the magnetic mirror field through the quartz limiter. Thus, a radius of core plasma could be determined by the limiter, which was 15 mm in this study. Plasma parameters were investigated by the Langmuir probe measurement. High-density plasma larger than 1011 cm-3 could be produced by applying 5.85-GHz microwave power of 10 W or more. For the outside region of the core plasma where a wafer for plasma processings will be set at, the ion current density was decreased dramatically with distance from the core plasma and became smaller by approximately two orders of magnitude that in the core plasma region for the radial position of 40 mm, suggesting the realization of reduction in ion bombardment damages.

  8. Mirror-field confined compact plasma source using permanent magnet for plasma processings.

    Science.gov (United States)

    Goto, Tetsuya; Sato, Kei-Ichiro; Yabuta, Yuki; Sugawa, Shigetoshi

    2016-12-01

    A mirror-field confined compact electron cyclotron resonance (ECR) plasma source using permanent magnets was developed, aiming for the realization of high-quality plasma processings where high-density reactive species are supplied to a substrate with minimizing the ion bombardment damages. The ECR position was located between a microwave transmissive window and a quartz limiter, and plasmas were transported from the ECR position to a midplane of the magnetic mirror field through the quartz limiter. Thus, a radius of core plasma could be determined by the limiter, which was 15 mm in this study. Plasma parameters were investigated by the Langmuir probe measurement. High-density plasma larger than 10(11) cm(-3) could be produced by applying 5.85-GHz microwave power of 10 W or more. For the outside region of the core plasma where a wafer for plasma processings will be set at, the ion current density was decreased dramatically with distance from the core plasma and became smaller by approximately two orders of magnitude that in the core plasma region for the radial position of 40 mm, suggesting the realization of reduction in ion bombardment damages.

  9. A low-energy linear oxygen plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Anders, Andre; Yushkov, Georgy Yu.

    2007-01-08

    A new version of a Constricted Plasma Source is described,characterized by all metal-ceramic construction, a linear slit exit of180 mm length, and cw-operation (typically 50 kHz) at an average power of1.5 kW. The plasma source is here operated with oxygen gas, producingstreaming plasma that contains mainly positive molecular and atomic ions,and to a much lesser degree, negative ions. The maximum total ion currentobtained was about 0.5 A. The fraction of atomic ions reached more than10 percent of all ions when the flow rate was less then 10 sccm O2,corresponding to a chamber pressure of about 0.5 Pa for the selectedpumping speed. The energy distribution functions of the different ionspecies were measured with a combinedmass spectrometer and energyanalyzer. The time-averaged distribution functions were broad and rangedfrom about 30eV to 90 eV at 200 kHz and higher frequencies, while theywere only several eV broad at 50 kHz and lower frequencies, with themaximum located at about 40 eV for the grounded anode case. This maximumwas shifted down to about 7 eV when the anode was floating, indicatingthe important role of the plasma potential for the ion energy for a givensubstrate potential. The source could be scaled to greater length and maybe useful for functionalization of surfaces and plasma-assisteddeposition of compound films.

  10. Ion transport from plasma ion source at ISOLTRAP

    CERN Document Server

    Steinsberger, Timo Pascal

    2017-01-01

    In this report, my work as CERN Summer Student at the ISOLTRAP experiment at ISOLDE is described. A new plasma ion source used as oine source for calibration and implemented before my arrival was commissioned and transportation settings for the produced ions to the ion traps were found. The cyclotron frequencies of 40Ar and the xenon isotopes 129-132Xe were measured using time-of-flight and phase-imaging ion-cyclotron-resonance mass spectroscopy.

  11. VUV SOURCE FROM PULSED-LASER GENERATED PLASMA

    OpenAIRE

    Laporte, P.; Damany, N.; Damany, H.

    1987-01-01

    We describe a pulsed vacuum ultraviolet (VUV) source consisting of a plasma created by focusing a NdYAG laser beam into rare gases under moderate pressure, and we report on spectral and time properties of that source. Main features are : continuum emission in a large spectral range, with only few lines superimposed, good time characteristics of the pulses, stability, cleanliness, and relatively high repetition rate (20 Hz).

  12. Plasma ion sources and ion beam technology inmicrofabrications

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Lili [Univ. of California, Berkeley, CA (United States)

    2007-01-01

    For over decades, focused ion beam (FIB) has been playing a very important role in microscale technology and research, among which, semiconductor microfabrication is one of its biggest application area. As the dimensions of IC devices are scaled down, it has shown the need for new ion beam tools and new approaches to the fabrication of small-scale devices. In the meanwhile, nanotechnology has also deeply involved in material science research and bioresearch in recent years. The conventional FIB systems which utilize liquid gallium ion sources to achieve nanometer scale resolution can no longer meet the various requirements raised from such a wide application area such as low contamination, high throughput and so on. The drive towards controlling materials properties at nanometer length scales relies on the availability of efficient tools. In this thesis, three novel ion beam tools have been developed and investigated as the alternatives for the conventional FIB systems in some particular applications. An integrated focused ion beam (FIB) and scanning electron microscope (SEM) system has been developed for direct doping or surface modification. This new instrument employs a mini-RF driven plasma source to generate focused ion beam with various ion species, a FEI two-lens electron (2LE) column for SEM imaging, and a five-axis manipulator system for sample positioning. An all-electrostatic two-lens column has been designed to focus the ion beam extracted from the source. Based on the Munro ion optics simulation, beam spot sizes as small as 100 nm can be achieved at beam energies between 5 to 35 keV if a 5 μm-diameter extraction aperture is used. Smaller beam spot sizes can be obtained with smaller apertures at sacrifice of some beam current. The FEI 2LE column, which utilizes Schottky emission, electrostatic focusing optics, and stacked-disk column construction, can provide high-resolution (as small as 20 nm) imaging capability, with fairly long working distance (25

  13. Modeling of plasma transport and negative ion extraction in a magnetized radio-frequency plasma source

    Science.gov (United States)

    Fubiani, G.; Garrigues, L.; Hagelaar, G.; Kohen, N.; Boeuf, J. P.

    2017-01-01

    Negative ion sources for fusion are high densities plasma sources in large discharge volumes. There are many challenges in the modeling of these sources, due to numerical constraints associated with the high plasma density, to the coupling between plasma and neutral transport and chemistry, the presence of a magnetic filter, and the extraction of negative ions. In this paper we present recent results concerning these different aspects. Emphasis is put on the modeling approach and on the methods and approximations. The models are not fully predictive and not complete as would be engineering codes but they are used to identify the basic principles and to better understand the physics of the negative ion sources.

  14. Effect of Substrate Potential on Plasma Parameters of Magnetic Multicusp Plasma Source

    Science.gov (United States)

    Ueda, Yoshio; Goto, Masahiro

    1998-06-01

    The effect of substrate potential on plasmas produced in a magnetic multicusp plasma source has been studied experimentally. Plasma parameters such as electron temperature and plasma potential are estimated from electron energy distribution function numerically calculated from probe current-voltage characteristics. For a substrate potential of -150 V with respect to the source chamber, which is much lower than substrate floating potentials, the plasma parameters are not affected by the application of the potential. However, for the case where the substrate is shorted with the source chamber, the high energy component of electrons significantly decreases in comparison with the floating case leading to the reduction of electron temperature. In this case, plasma potential is positive with respect to the substrate to suppress electron loss but its absolute value is only of the order of electron temperature in eV, which is much lower than the potential between the plasma and the substrate in the floating case. This discharge mode could be advantageous in significantly reducing the ion impact energy to the substrate plate.

  15. Science reporting in Accra, Ghana: sources, barriers and motivational factors.

    Science.gov (United States)

    Appiah, Bernard; Gastel, Barbara; Burdine, James N; Russell, Leon H

    2015-01-01

    In Ghana, as in many other developing countries, most science reporting is done by general reporters. However, few studies have investigated science reporting in such a situation. To understand better the dynamics of science reporting in such context, we surveyed 151 general reporters in Ghana. Respondents' demographic characteristics resembled those found in studies elsewhere. Respondents perceived health professionals and scientists as very important sources of information for reporting science. There was an inverse correlation between journalism experience and the number of science feature stories reported in the past 12 months (p=.017). Most respondents indicated that science journalism training would motivate them to report science more. Likewise, most reported that easier access to research findings would do so. We identify characteristics of reporters, media, scientific, and training institutions that are important influences of Ghanaian reporters' coverage of science. We provide recommendations for advancing science reporting in Ghana. © The Author(s) 2014.

  16. Science reporting in Accra, Ghana: Sources, barriers and motivational factors

    Science.gov (United States)

    Gastel, Barbara; Burdine, James N.; Russell, Leon H.

    2014-01-01

    In Ghana, as in many other developing countries, most science reporting is done by general reporters. However, few studies have investigated science reporting in such a situation. To understand better the dynamics of science reporting in such context, we surveyed 151 general reporters in Ghana. Respondents’ demographic characteristics resembled those found in studies elsewhere. Respondents perceived health professionals and scientists as very important sources of information for reporting science. There was an inverse correlation between journalism experience and the number of science feature stories reported in the past 12 months (p = .017). Most respondents indicated that science journalism training would motivate them to report science more. Likewise, most reported that easier access to research findings would do so. We identify characteristics of reporters, media, scientific, and training institutions that are important influences of Ghanaian reporters’ coverage of science. We provide recommendations for advancing science reporting in Ghana. PMID:25193967

  17. Three Filtered Vacuum Arc Plasma Sources Deposition & Implantation System

    Institute of Scientific and Technical Information of China (English)

    WU Xian-ying; ZHANG Hui-xing; LI Qiang

    2004-01-01

    A deposition & implantation system, which includes three filtered vacuum arc plasma sources, has been built. Vacuum arc discharge is used to produce high-density metal plasma; Curved magnetic filtering technique is used to transfer the plasma into out-of-sight vacuum chamber and reduce macro-particles from the vacuum arc plasma in order to drastically reduce the macro-particles contamination of the films. The up to 30 kV negative bias applied to the target can be used for ion implantation in order to improve the film adhesion; or for ion sputtering to clear the substrate surface. The 0 to 300 V negative bias can be used to adjust the ion energy which forming films. The system is designed for various thin films synthesizing, such as single-layer, compound layer, multi-layer films. It's principle, components and applications are described in the literature.

  18. RF Plasma modeling of the Linac4 H− ion source

    CERN Document Server

    Mattei, S; Hatayama, A; Lettry, J; Kawamura, Y; Yasumoto, M; Schmitzer, C

    2013-01-01

    This study focuses on the modelling of the ICP RF-plasma in the Linac4 H− ion source currently being constructed at CERN. A self-consistent model of the plasma dynamics with the RF electromagnetic field has been developed by a PIC-MCC method. In this paper, the model is applied to the analysis of a low density plasma discharge initiation, with particular interest on the effect of the external magnetic field on the plasma properties, such as wall loss, electron density and electron energy. The use of a multi-cusp magnetic field effectively limits the wall losses, particularly in the radial direction. Preliminary results however indicate that a reduced heating efficiency results in such a configuration. The effect is possibly due to trapping of electrons in the multi-cusp magnetic field, preventing their continuous acceleration in the azimuthal direction.

  19. Study on Performance Parameters of the Plasma Source for a Short-Conduction-Time Plasma Opening Switch

    Institute of Scientific and Technical Information of China (English)

    LUO Weixi; ZENG Zhengzhong; WANG Liangping; LEI Tianshi; HU Yixiang; HUANG Tao; SUN Tieping

    2012-01-01

    Plasma source performance parameters, including plasma ejection density and velocity, greatly affect the operation of a short-conduction-time plasma opening switch (POS). In this paper, the plasma source used in the POS of Qiangguang I generator is chosen as the study object. At first the POS working process is analyzed. The result shows that the opening performance of the POS can be improved by increasing the plasma ejection velocity and decreasing the plasma density. The influence of the cable plasma gun structure and number on the plasma ejection parameters is experimentally investigated with two charge collectors. Finally a semi-empirical model is proposed to describe the experimental phenomenon.

  20. Modeling of negative ion transport in a plasma source

    Science.gov (United States)

    Riz, David; Paméla, Jérôme

    1998-08-01

    A code called NIETZSCHE has been developed to simulate the negative ion transport in a plasma source, from their birth place to the extraction holes. The ion trajectory is calculated by numerically solving the 3-D motion equation, while the atomic processes of destruction, of elastic collision H-/H+ and of charge exchange H-/H0 are handled at each time step by a Monte-Carlo procedure. This code can be used to calculate the extraction probability of a negative ion produced at any location inside the source. Calculations performed with NIETZSCHE have allowed to explain, either quantitatively or qualitatively, several phenomena observed in negative ion sources, such as the isotopic H-/D- effect, and the influence of the plasma grid bias or of the magnetic filter on the negative ion extraction. The code has also shown that in the type of sources contemplated for ITER, which operate at large arc power densities (>1 W cm-3), negative ions can reach the extraction region provided if they are produced at a distance lower than 2 cm from the plasma grid in the case of «volume production» (dissociative attachment processes), or if they are produced at the plasma grid surface, in the vicinity of the extraction holes.

  1. Modeling of negative ion transport in a plasma source (invited)

    Science.gov (United States)

    Riz, David; Paméla, Jérôme

    1998-02-01

    A code called NIETZSCHE has been developed to simulate the negative ion transport in a plasma source, from their birth place to the extraction holes. The H-/D- trajectory is calculated by numerically solving the 3D motion equation, while the atomic processes of destruction, of elastic collision with H+/D+ and of charge exchange with H0/D0 are handled at each time step by a Monte Carlo procedure. This code can be used to calculate the extraction probability of a negative ion produced at any location inside the source. Calculations performed with NIETZSCHE have been allowed to explain, either quantitatively or qualitatively, several phenomena observed in negative ion sources, such as the isotopic H-/D- effect, and the influence of the plasma grid bias or of the magnetic filter on the negative ion extraction. The code has also shown that, in the type of sources contemplated for ITER, which operate at large arc power densities (>1 W cm-3), negative ions can reach the extraction region provided they are produced at a distance lower than 2 cm from the plasma grid in the case of volume production (dissociative attachment processes), or if they are produced at the plasma grid surface, in the vicinity of the extraction holes.

  2. Large-Area Permanent-Magnet ECR Plasma Source

    Science.gov (United States)

    Foster, John E.

    2007-01-01

    A 40-cm-diameter plasma device has been developed as a source of ions for material-processing and ion-thruster applications. Like the device described in the immediately preceding article, this device utilizes electron cyclotron resonance (ECR) excited by microwave power in a magnetic field to generate a plasma in an electrodeless (noncontact) manner and without need for an electrically insulating, microwave-transmissive window at the source. Hence, this device offers the same advantages of electrodeless, windowless design - low contamination and long operational life. The device generates a uniform, high-density plasma capable of sustaining uniform ion-current densities at its exit plane while operating at low pressure [magnetic field in this device is generated by a permanent-magnet circuit that is optimized to generate resonance surfaces. The microwave power is injected on the centerline of the device. The resulting discharge plasma jumps into a "high mode" when the input power rises above 150 W. This mode is associated with elevated plasma density and high uniformity. The large area and uniformity of the plasma and the low operating pressure are well suited for such material-processing applications as etching and deposition on large silicon wafers. The high exit-plane ion-current density makes it possible to attain a high rate of etching or deposition. The plasma potential is <3 V low enough that there is little likelihood of sputtering, which, in plasma processing, is undesired because it is associated with erosion and contamination. The electron temperature is low and does not vary appreciably with power.

  3. Intense ion beam generation, plasma radiation source and plasma opening switch research

    Science.gov (United States)

    Hammer, D. A.; Coleman, M. D.; Qi, N.; Similon, P. L.; Sudan, R. N.

    1989-04-01

    This report describes research on intense ion beam diodes, plasma opening switches and dense z-pinch plasma radiators. Laser induced fluorescence spectroscopy has been used to map the electrostatic potential profile in a plasma-prefilled magnetically insulated ion diode. In a simple planar diode, the measured profile is inconsistent with the electrons being confined in a sheath near the cathode by the magnetic field. Rather, the profile implies the presence of electrons throughout the accelerating gap. A theoretical model of the penetration of current and magnetic field into a plasma, and of the current-driven effective collision frequency has been developed. The snowplow action of the rising magnetic field causes a steep rise in the plasma density at the leading edge. The subsequent multistreaming of the ions caused by ion reflection at the current layer could lead to ion heating through collective effects. The two-dimensional electron flow in the plasma cathode vacuum gap is also treated. Dense z-pinch plasma radiation source experiments have been initiated on the LION accelerator using gas puff and fine wire loads. The x-pinch was found to be a more effective way to generate soft x-rays than a single wire pinch or a gas puff implosion. Plasma opening switch experiments being initiated, and plasma anode ion diode development work being terminated are also briefly described.

  4. Plasma and Ion Sources in Large Area Coatings: A Review

    Energy Technology Data Exchange (ETDEWEB)

    Anders, Andre

    2005-02-28

    Efficient deposition of high-quality coatings often requires controlled application of excited or ionized particles. These particles are either condensing (film-forming) or assisting by providing energy and momentum to the film growth process, resulting in densification, sputtering/etching, modification of stress, roughness, texture, etc. In this review, the technical means are surveyed enabling large area application of ions and plasmas, with ion energies ranging from a few eV to a few keV. Both semiconductortype large area (single wafer or batch processing with {approx} 1000 cm{sup 2}) and in-line web and glass-coating-type large area (> 10{sup 7} m{sup 2} annually) are considered. Characteristics and differences between plasma and ion sources are explained. The latter include gridded and gridless sources. Many examples are given, including sources based on DC, RF, and microwave discharges, some with special geometries like hollow cathodes and E x B configurations.

  5. Kinetic models for the VASIMR thruster helicon plasma source

    Science.gov (United States)

    Batishchev, Oleg; Molvig, Kim

    2001-10-01

    Helicon gas discharge [1] is widely used by industry because of its remarkable efficiency [2]. High energy and fuel efficiencies make it very attractive for space electrical propulsion applications. For example, helicon plasma source is used in the high specific impulse VASIMR [3] plasma thruster, including experimental prototypes VX-3 and upgraded VX-10 [4] configurations, which operate with hydrogen (deuterium) and helium plasmas. We have developed a set of models for the VASIMR helicon discharge. Firstly, we use zero-dimensional energy and mass balance equations to characterize partially ionized gas condition/composition. Next, we couple it to one-dimensional hybrid model [6] for gas flow in the quartz tube of the helicon. We compare hybrid model results to a purely kinetic simulation of propellant flow in gas feed + helicon source subsystem. Some of the experimental data [3-4] are explained. Lastly, we discuss full-scale kinetic modeling of coupled gas and plasmas [5-6] in the helicon discharge. [1] M.A.Lieberman, A.J.Lihtenberg, 'Principles of ..', Wiley, 1994; [2] F.F.Chen, Plas. Phys. Contr. Fus. 33, 339, 1991; [3] F.Chang-Diaz et al, Bull. APS 45 (7) 129, 2000; [4] J.Squire et al., Bull. APS 45 (7) 130, 2000; [5] O.Batishchev et al, J. Plasma Phys. 61, part II, 347, 1999; [6] O.Batishchev, K.Molvig, AIAA technical paper 2000-3754, -14p, 2001.

  6. FOREWORD: 23rd National Symposium on Plasma Science & Technology (PLASMA-2008)

    Science.gov (United States)

    Das, A. K.

    2010-01-01

    The Twentieth Century has been a defining period for Plasma Science and Technology. The state of ionized matter, so named by Irving Langmuir in the early part of twentieth century, has now evolved in to a multidisciplinary area with scientists and engineers from various specializations working together to exploit the unique properties of the plasma medium. There have been great improvements in the basic understanding of plasmas as a many body system bound by complex collective Coulomb interactions of charges, atoms, molecules, free radicals and photons. Simultaneously, many advanced plasma based technologies are increasingly being implemented for industrial and societal use. The emergence of the multination collaborative project International Thermonuclear Experimental Reactor (ITER) project has provided the much needed boost to the researchers working on thermonuclear fusion plasmas. In addition, the other plasma applications like MHD converters, hydrogen generation, advanced materials (synthesis, processing and surface modification), environment (waste beneficiation, air and water pollution management), nanotechnology (synthesis, deposition and etching), light production, heating etc are actively being pursued in governmental and industrial sectors. For India, plasma science and technology has traditionally remained an important area of research. It was nearly a century earlier that the Saha ionization relation pioneered the way to interpret experimental data from a vast range of near equilibrium plasmas. Today, Indian research contributions and technology demonstration capabilities encompass thermonuclear fusion devices, nonlinear plasma phenomena, plasma accelerators, beam plasma interactions, dusty and nonneutral plasmas, industrial plasmas and plasma processing of materials, nano synthesis and structuring, astrophysical and space plasmas etc. India's participation in the ITER programme is now reflected in increased interest in the research and development

  7. Oscillating plasma bubbles. III. Internal electron sources and sinks

    Energy Technology Data Exchange (ETDEWEB)

    Stenzel, R. L.; Urrutia, J. M. [Department of Physics and Astronomy, University of California, Los Angeles, California 90095-1547 (United States)

    2012-08-15

    An internal electron source has been used to neutralize ions injected from an ambient plasma into a spherical grid. The resultant plasma is termed a plasma 'bubble.' When the electron supply from the filament is reduced, the sheath inside the bubble becomes unstable. The plasma potential of the bubble oscillates near but below the ion plasma frequency. Different modes of oscillations have been observed as well as a subharmonic and multiple harmonics. The frequency increases with ion density and decreases with electron density. The peak amplitude occurs for an optimum current and the instability is quenched at large electron densities. The frequency also increases if Langmuir probes inside the bubble draw electrons. Allowing electrons from the ambient plasma to enter, the bubble changes the frequency dependence on grid voltage. It is concluded that the net space charge density in the sheath determines the oscillation frequency. It is suggested that the sheath instability is caused by ion inertia in an oscillating sheath electric field which is created by ion bunching.

  8. The ITER full size plasma source device design

    Energy Technology Data Exchange (ETDEWEB)

    Sonato, P. [Consorzio RFX, EURATOM-ENEA Association, Corso Stati Uniti 4, I-35127 Padova (Italy)], E-mail: piergiorgio.sonato@igi.cnr.it; Agostinetti, P.; Anaclerio, G.; Antoni, V.; Barana, O.; Bigi, M.; Boldrin, M. [Consorzio RFX, EURATOM-ENEA Association, Corso Stati Uniti 4, I-35127 Padova (Italy); Cavenago, M. [INFN, Legnaro, Padova (Italy); Dal Bello, S.; Palma, M. Dalla [Consorzio RFX, EURATOM-ENEA Association, Corso Stati Uniti 4, I-35127 Padova (Italy); Daniele, A. [ENEA, Frascati, Roma (Italy); D' Arienzo, M.; De Lorenzi, A.; Ferro, A.; Fiorentin, A.; Gaio, E.; Gazza, E.; Grando, L.; Fantini, F.; Fellin, F. [Consorzio RFX, EURATOM-ENEA Association, Corso Stati Uniti 4, I-35127 Padova (Italy)] (and others)

    2009-06-15

    In the framework of the strategy for the development and the procurement of the NB systems for ITER, it has been decided to build in Padova a test facility, including two experimental devices: a full size plasma source with low voltage extraction and a full size NB injector at full beam power (1 MV). These two different devices will separately address the main scientific and technological issues of the 17 MW NB injector for ITER. In particular the full size plasma source of negative ions will address the ITER performance requirements in terms of current density and uniformity, limitation of the electron/ion ratio and stationary operation at full current with high reliability and constant performances for the whole operating time up to 1 h. The required negative ion current density to be extracted from the plasma source ranges from 290 A/m{sup 2} in D{sub 2} (D{sup -}) and 350 A/m{sup 2} in H{sub 2} (H{sup -}) and these values should be obtained at the lowest admissible neutral pressure in the plasma source volume, nominally at 0.3 Pa. The electron to ion ratio should be limited to less than 1 and the admissible ion inhomogeneity extracted from the grids should be better than 10% on the whole plasma cross-section having a surface exposed to the extraction grid of the order of 1 m{sup 2}. The main design choices will be presented in the paper as well as an overview of the design of the main components and systems.

  9. Minority Preservice Teachers' Conceptions of Teaching Science: Sources of Science Teaching Strategies

    Science.gov (United States)

    Subramaniam, Karthigeyan

    2013-01-01

    This study explores five minority preservice teachers' conceptions of teaching science and identifies the sources of their strategies for helping students learn science. Perspectives from the literature on conceptions of teaching science and on the role constructs used to describe and distinguish minority preservice teachers from their mainstream…

  10. Plasma Science and Applications at the Intel Science Fair: A Retrospective

    Science.gov (United States)

    Berry, Lee

    2009-11-01

    For the past five years, the Coalition for Plasma Science (CPS) has presented an award for a plasma project at the Intel International Science and Engineering Fair (ISEF). Eligible projects have ranged from grape-based plasma production in a microwave oven to observation of the effects of viscosity in a fluid model of quark-gluon plasma. Most projects have been aimed at applications, including fusion, thrusters, lighting, materials processing, and GPS improvements. However diagnostics (spectroscopy), technology (magnets), and theory (quark-gluon plasmas) have also been represented. All of the CPS award-winning projects so far have been based on experiments, with two awards going to women students and three to men. Since the award was initiated, both the number and quality of plasma projects has increased. The CPS expects this trend to continue, and looks forward to continuing its work with students who are excited about the possibilities of plasma. You too can share this excitement by judging at the 2010 fair in San Jose on May 11-12.

  11. Plasma Science and Applications at the Intel International Science and Engineering Fair

    Science.gov (United States)

    Berry, Lee

    2005-10-01

    The Coalition for Plasma Science (CPS) has established a plasma prize at the Intel International Science and Engineering Fair (ISEF). This year's prize was awarded for projects in simulated ball lightning and plasma thrusters. The CPS is a broadly-based group of institutions and individuals whose goal is to increase the understanding of plasmas for non-technical audiences. In addition to the ISEF plasma award, CPS activities include maintaining a website, http://www.plasmacoalition.org; developing educational literature; organizing educational luncheon presentations for Members of Congress and their staffs; and responding to questions about plasmas that are received by the CPS e-mail or toll-free number. The success of these activities depend on the voluntary labor of CPS members and associates. These volunteers include the ISEF judges, whom the APS/DPP and the IEEE/PSAC helped identify. Please send an e-mail to the CPS at CPS@plasmacoalition.org for information if you would like to become involved in spreading the good word about plasmas.

  12. Plasma shape control by pulsed solenoid on laser ion source

    Science.gov (United States)

    Sekine, M.; Ikeda, S.; Romanelli, M.; Kumaki, M.; Fuwa, Y.; Kanesue, T.; Hayashizaki, N.; Lambiase, R.; Okamura, M.

    2015-09-01

    A Laser ion source (LIS) provides high current heavy ion beams with a very simple mechanical structure. Plasma is produced by a pulsed laser ablation of a solid state target and ions are extracted by an electric field. However, it was difficult to manipulate the beam parameters of a LIS, since the plasma condition could only be adjusted by the laser irradiation condition. To enhance flexibility of LIS operation, we employed a pulsed solenoid in the plasma drift section and investigated the effect of the solenoid field on singly charged iron beams. The experimentally obtained current profile was satisfactorily controlled by the pulsed magnetic field. This approach may also be useful to reduce beam emittance of a LIS.

  13. Plasma shape control by pulsed solenoid on laser ion source

    Energy Technology Data Exchange (ETDEWEB)

    Sekine, M. [Tokyo Institute of Technology, Meguro-ku, Tokyo 2-12-1 (Japan); RIKEN, Wako, Saitama 351-0198 (Japan); Ikeda, S. [Tokyo Institute of Technology, Yokohama, Kanagawa 226-8502 (Japan); RIKEN, Wako, Saitama 351-0198 (Japan); Romanelli, M. [Cornell University, Ithaca, NY 14850 (United States); Kumaki, M. [RIKEN, Wako, Saitama 351-0198 (Japan); Waseda University, Shinjuku, Tokyo 169-0072 (Japan); Fuwa, Y. [RIKEN, Wako, Saitama 351-0198 (Japan); Kyoto University, Uji, Kyoto 611-0011 (Japan); Kanesue, T. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Hayashizaki, N. [Tokyo Institute of Technology, Meguro-ku, Tokyo 2-12-1 (Japan); Lambiase, R. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Okamura, M. [RIKEN, Wako, Saitama 351-0198 (Japan); Brookhaven National Laboratory, Upton, NY 11973 (United States)

    2015-09-21

    A Laser ion source (LIS) provides high current heavy ion beams with a very simple mechanical structure. Plasma is produced by a pulsed laser ablation of a solid state target and ions are extracted by an electric field. However, it was difficult to manipulate the beam parameters of a LIS, since the plasma condition could only be adjusted by the laser irradiation condition. To enhance flexibility of LIS operation, we employed a pulsed solenoid in the plasma drift section and investigated the effect of the solenoid field on singly charged iron beams. The experimentally obtained current profile was satisfactorily controlled by the pulsed magnetic field. This approach may also be useful to reduce beam emittance of a LIS.

  14. Hydrogen Plasma Generation with 200 MHz RF Ion Source

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeongtae; Park, Kwangmook; Seo, Dong Hyuk; Kim, Han-Sung; Kwon, Hyeok-Jung; Cho, Yong-Sub [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    The ion source for the system is required to be rugged with 2000 hours maintenance free operation time because it is installed in the vessel filled with SF6 gas at the pressure of 10 bar. A 200 MHz RF ion source is considered as an ion source. It is a simple construction and provides long life operation. The specifications of the ion source are 5 kV extraction voltage and 1 mA beam current referenced to the proton. RF ion source has been developed and undergone a performance test. Results of the test are presented. 200 MHz RF ion source is designated and manufactured. First of all test stand test of ion source are set up for a performance test of ion source. It includes a RF ion source, a 200-MHz RF system, beam extraction system, vacuum system, beam extraction system, and beam diagnostic system. At pressure of 1.2E-5 torr, hydrogen plasma is generated with net RF power 70 W. Pyrex tube surrounded by an inductive coil takes the role of vessel and discharge is enhanced with field of permanent magnets.

  15. Laser-driven electron beam and radiation sources for basic, medical and industrial sciences.

    Science.gov (United States)

    Nakajima, Kazuhisa

    2015-01-01

    To date active research on laser-driven plasma-based accelerators have achieved great progress on production of high-energy, high-quality electron and photon beams in a compact scale. Such laser plasma accelerators have been envisaged bringing a wide range of applications in basic, medical and industrial sciences. Here inheriting the groundbreaker's review article on "Laser Acceleration and its future" [Toshiki Tajima, (2010)],(1)) we would like to review recent progress of producing such electron beams due to relativistic laser-plasma interactions followed by laser wakefield acceleration and lead to the scaling formulas that are useful to design laser plasma accelerators with controllability of beam energy and charge. Lastly specific examples of such laser-driven electron/photon beam sources are illustrated.

  16. Open Genetic Code: on open source in the life sciences.

    Science.gov (United States)

    Deibel, Eric

    2014-01-01

    The introduction of open source in the life sciences is increasingly being suggested as an alternative to patenting. This is an alternative, however, that takes its shape at the intersection of the life sciences and informatics. Numerous examples can be identified wherein open source in the life sciences refers to access, sharing and collaboration as informatic practices. This includes open source as an experimental model and as a more sophisticated approach of genetic engineering. The first section discusses the greater flexibly in regard of patenting and the relationship to the introduction of open source in the life sciences. The main argument is that the ownership of knowledge in the life sciences should be reconsidered in the context of the centrality of DNA in informatic formats. This is illustrated by discussing a range of examples of open source models. The second part focuses on open source in synthetic biology as exemplary for the re-materialization of information into food, energy, medicine and so forth. The paper ends by raising the question whether another kind of alternative might be possible: one that looks at open source as a model for an alternative to the commodification of life that is understood as an attempt to comprehensively remove the restrictions from the usage of DNA in any of its formats.

  17. A novel plasma source for sterilization of living tissues

    Energy Technology Data Exchange (ETDEWEB)

    Martines, E; Zuin, M; Cavazzana, R; Gazza, E; Serianni, G; Spagnolo, S; Spolaore, M [Consorzio RFX, Associazione Euratom-ENEA sulla Fusione, Padova (Italy); Leonardi, A; Deligianni, V [Department of Neuroscience, Ophthalmology Unit, University of Padova (Italy); Brun, P; Aragona, M [Department of Histology, Microbiology and Medical Biotechnology, Histology Unit, University of Padova (Italy); Castagliuolo, I; Brun, P [Department of Histology, Microbiology and Medical Biotechnology, Microbiology Unit, University of Padova (Italy)], E-mail: emilio.martines@igi.cnr.it

    2009-11-15

    A source for the production of low-power plasmas at atmospheric pressure, to be used for the nondamaging sterilization of living tissues, is presented. The source, powered by radiofrequency and working with a helium flow, has a specific configuration, studied to prevent the formation of electric arcs dangerous to living matter. It is capable of killing different types of bacteria with a decimal reduction time of 1-2 min; on the contrary, human cells such as conjunctival fibroblasts were found to be almost unharmed by the plasma. A high concentration of OH radicals, likely to be the origin of the sterilizing effect, is detected through their UV emission lines. The effect of the UV and the OH radicals on the fibroblasts was analysed and no significant effects were detected.

  18. Applications of plasma sources for nitric oxide medicine

    Science.gov (United States)

    Vasilets, Victor; Shekhter, Anatoly; Pekshev, Alexander

    2013-09-01

    Nitric oxide (NO) has important roles in the function of many tissues and organs. Wound healing processes are always accompanying by the increase of nitric oxide concentration in wound tissue. These facts suggest a possible therapeutic use of various NO donors for the acceleration of the wound healing and treatment of other diseases. Our previous studies indicated that gaseous NO flow produced by air-plasma generators acts beneficially on the wound healing. This beneficial effect could be caused by the mechanism involving peroxynitrite as an intermediate. As a result of mobilization of various antioxidant reactions more endogenous NO molecules become available as signaling molecules. to regulate the metabolic processes in wound tissue. In this paper different air plasma sources generated therapeutic concentrations of NO are discussed. The concentration of NO and other therapeutically important gas products are estimated by thermodynamic simulation. Synergy effects of NO with other plasma components are discussed as a factor enhancing therapeutic results. Some new medical application of plasma devices are presented. Advanced Plasma Therapies Inc.

  19. Tin LPP plasma control in the argon cusp source

    Science.gov (United States)

    McGeoch, Malcolm W.

    2016-03-01

    The argon cusp plasma has been introduced [1,2] for 500W class tin LPP exhaust control in view of its high power handling, predicted low tin back-scatter from a beam dump, and avoidance of hydrogen usage. The physics of tin ion control by a plasma is first discussed. Experimentally, cusp stability and exhaust disc geometry have previously been proved at full scale [2], the equivalent of 300W-500W usable EUV. Here we verify operation of the plasma barrier that maintains a high argon density next to the collector, for its protection, and a low density in the long path toward the intermediate focus, for efficiency. A pressure differential of 2Pa has been demonstrated in initial work. Other aspects of tin LPP plasma control by the cusp have now been demonstrated using tin ions from a low Hz 130mJ CO2 laser pulse onto a solid tin surface at the cusp center. Plasma is rejected at the design to match a specified exhaust power is discussed. In view of this work, argon cusp exhaust control appears to be very promising for 500W class tin LPP sources.

  20. Sheath overlap during very large scale plasma source ion implantation

    Science.gov (United States)

    Cluggish, B. P.; Munson, C. P.

    1998-12-01

    Measurements of plasma source ion implantation have been performed on a large target of complex geometry. The target consists of 1000 aluminum, automotive piston surrogates mounted on four racks; total surface area is over 16 m2. The four racks are positioned parallel to each other, 0.25 m apart, in an 8 m3 vacuum chamber. The racks of pistons are immersed in a capacitive radio frequency plasma, with an argon gas pressure of 20-65 mPa. Langmuir probe measurements indicate that the plasma density profile is highly nonuniform, due to particle losses to the racks of pistons. The plasma ions are implanted into the pistons by pulse biasing the workpiece to negative voltages as low as -18 kV for up to 20 μs. During the voltage pulse, the high-voltage sheaths from adjacent racks of pistons converge towards each other. At plasma densities less than 109 cm-3 the sheaths are observed to overlap. Measurements of the sheath overlap time are compared with standard analytic theory and with simulations run with a two-dimensional particle-in-cell code.

  1. Laboratory Plasma Source as an MHD Model for Astrophysical Jets

    Science.gov (United States)

    Mayo, Robert M.

    1997-01-01

    The significance of the work described herein lies in the demonstration of Magnetized Coaxial Plasma Gun (MCG) devices like CPS-1 to produce energetic laboratory magneto-flows with embedded magnetic fields that can be used as a simulation tool to study flow interaction dynamic of jet flows, to demonstrate the magnetic acceleration and collimation of flows with primarily toroidal fields, and study cross field transport in turbulent accreting flows. Since plasma produced in MCG devices have magnetic topology and MHD flow regime similarity to stellar and extragalactic jets, we expect that careful investigation of these flows in the laboratory will reveal fundamental physical mechanisms influencing astrophysical flows. Discussion in the next section (sec.2) focuses on recent results describing collimation, leading flow surface interaction layers, and turbulent accretion. The primary objectives for a new three year effort would involve the development and deployment of novel electrostatic, magnetic, and visible plasma diagnostic techniques to measure plasma and flow parameters of the CPS-1 device in the flow chamber downstream of the plasma source to study, (1) mass ejection, morphology, and collimation and stability of energetic outflows, (2) the effects of external magnetization on collimation and stability, (3) the interaction of such flows with background neutral gas, the generation of visible emission in such interaction, and effect of neutral clouds on jet flow dynamics, and (4) the cross magnetic field transport of turbulent accreting flows. The applicability of existing laboratory plasma facilities to the study of stellar and extragalactic plasma should be exploited to elucidate underlying physical mechanisms that cannot be ascertained though astrophysical observation, and provide baseline to a wide variety of proposed models, MHD and otherwise. The work proposed herin represents a continued effort on a novel approach in relating laboratory experiments to

  2. A microwave plasma source for VUV atmospheric photochemistry

    OpenAIRE

    Tigrine, Sarah; Carrasco, Nathalie; Vettier, Ludovic; Cernogora, Guy

    2017-01-01

    International audience; Microwave plasma discharges working at low pressure are nowadays a well-developed technique mainly used to provide radiations at different wavelengths. The aim of this work is to show that those discharges are an efficient windowless VUV photon source for planetary atmospheric photochemistry experiments. To do this, we use a surfatron-type discharge with a neon gas flow in the mbar pressure range coupled to a photochemical reactor. Working in the VUV range allows to fo...

  3. High Current, High Density Arc Plasma as a New Source for WiPAL

    Science.gov (United States)

    Waleffe, Roger; Endrizzi, Doug; Myers, Rachel; Wallace, John; Clark, Mike; Forest, Cary; WiPAL Team

    2016-10-01

    The Wisconsin Plasma Astrophysics Lab (WiPAL) has installed a new array of nineteen plasma sources (plasma guns) on its 3 m diameter, spherical vacuum vessel. Each gun is a cylindrical, molybdenum, washer-stabilized, arc plasma source. During discharge, the guns are maintained at 1.2 kA across 100 V for 10 ms by the gun power supply establishing a high density plasma. Each plasma source is fired independently allowing for adjustable plasma parameters, with densities varying between 1018 -1019 m-3 and electron temperatures of 5-15 eV. Measurements were characterized using a 16 tip Langmuir probe. The plasma source will be used as a background plasma for the magnetized coaxial plasma gun (MCPG), the Terrestrial Reconnection Experiment (TREX), and as the plasma source for a magnetic mirror experiment. Temperature, density, and confinement results will be presented. This work is supported by the DoE and the NSF.

  4. Improvement in brightness of multicusp-plasma ion source

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Q.; Jiang, X.; King, T-J.; Leung, K-N.; Standiford, K.; Wilde, S.B.

    2002-05-24

    The beam brightness of a multicusp-plasma ion source has been substantially improved by optimizing the source configuration and extractor geometry. The current density of a 2 keV He{sup +} beam extracted from a 7.5-cm-diameter source operating at 2.5 kW RF power is {approx}100 mA/cm{sup 2}, which is {approx}10 times larger than that of a beam extracted from a 5-cm-diameter source operating at 1 kW RF power. A smaller focused beam spot size is achieved with a counter-bored extractor instead of a conventional (''through-hole'') extractor, resulting another order of magnitude improvement in beam current density. Measured brightness can be as high as 440 A/cm{sup 2}Sr, which represents a 30 times improvement over prior work.

  5. Efficient cesiation in RF driven surface plasma negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Belchenko, Yu.; Ivanov, A.; Konstantinov, S.; Sanin, A., E-mail: sanin@inp.nsk.su; Sotnikov, O. [Budker Institute of Nuclear Physics, Siberian Branch of Russian Academy of Sciences, Novosibirsk (Russian Federation)

    2016-02-15

    Experiments on hydrogen negative ions production in the large radio-frequency negative ion source with cesium seed are described. The system of directed cesium deposition to the plasma grid periphery was used. The small cesium seed (∼0.5 G) provides an enhanced H{sup −} production during a 2 month long experimental cycle. The gradual increase of negative ion yield during the long-term source runs was observed after cesium addition to the source. The degraded H{sup −} production was recorded after air filling to the source or after the cesium washing away from the driver and plasma chamber walls. The following source conditioning by beam shots produces the gradual recovery of H{sup −} yield to the high value. The effect of H{sup −} yield recovery after cesium coverage passivation by air fill was studied. The concept of cesium coverage replenishment and of H{sup −} yield recovery due to sputtering of cesium from the deteriorated layers is discussed.

  6. High Power Light Gas Helicon Plasma Source For VASMIR

    Science.gov (United States)

    Squire, J. P.; Chang-Diaz, F. R.; Glover, T. W.; Jacobson, V. T.; McCaskill, G. E.; Winter, D. S.; Baity, F. W.; Carter, M. D.; Goulding, R. H.

    2004-01-01

    The VASIMR space propulsion development effort relies on a high power (greater than 10kW) helicon source to produce a dense flowing plasma (H, D and He) target for ion cyclotron resonance (ICR) acceleration of the ions. Subsequent expansion in an expanding magnetic field (magnetic nozzle) converts ion lunetic energy to directed momentum. This plasma source must have critical features to enable an effective propulsion device. First, it must ionize most of the input neutral flux of gas, thus producing a plasma stream with a high degree of ionization for application of ICR power. This avoids propellant waste and potential power losses due to charge exchange. Next, the plasma stream must flow into a region of high magnetic field (approximately 0.5 T) for efficient ICR acceleration. Third, the ratio of input power to plasma flux must be low, providing an energy per ion-electron pair approaching 100 eV. Lastly, the source must be robust and capable of very long life-times (years). In our helicon experiment (VX-10) we have measured a ratio of input gas to plasma flux near 100%. The plasma flows from the helicon region (B approximately 0.1 T) into a region with a peak magnetic field of 0.8 T. The energy input per ion-electron pair has been measured at 300 plus or minus 100 eV. Recent results at Oak Ridge National Laboratory (ORNL) show an enhanced efficiency mode of operation with a high power density, over 5 kW in a 5 cm diameter tube. Our helicon is presently 9 cm in diameter and operates up to 3.5 kW of input power. An upgrade to a power level of 10 kW is underway. Much of our recent work has been with a Boswell double-saddle antenna design. We are also converting the antenna design to a helical type. With these modifications, we anticipate an improvement in the ionization efficiency. This paper presents the results from scaling the helicon in the VX-10 device from 3.5 to 10 kW. We also compare the operation with a double-saddle to a helical antenna design. Finally, we

  7. High Power Light Gas Helicon Plasma Source For VASMIR

    Science.gov (United States)

    Squire, J. P.; Chang-Diaz, F. R.; Glover, T. W.; Jacobson, V. T.; McCaskill, G. E.; Winter, D. S.; Baity, F. W.; Carter, M. D.; Goulding, R. H.

    2004-01-01

    The VASIMR space propulsion development effort relies on a high power (greater than 10kW) helicon source to produce a dense flowing plasma (H, D and He) target for ion cyclotron resonance (ICR) acceleration of the ions. Subsequent expansion in an expanding magnetic field (magnetic nozzle) converts ion lunetic energy to directed momentum. This plasma source must have critical features to enable an effective propulsion device. First, it must ionize most of the input neutral flux of gas, thus producing a plasma stream with a high degree of ionization for application of ICR power. This avoids propellant waste and potential power losses due to charge exchange. Next, the plasma stream must flow into a region of high magnetic field (approximately 0.5 T) for efficient ICR acceleration. Third, the ratio of input power to plasma flux must be low, providing an energy per ion-electron pair approaching 100 eV. Lastly, the source must be robust and capable of very long life-times (years). In our helicon experiment (VX-10) we have measured a ratio of input gas to plasma flux near 100%. The plasma flows from the helicon region (B approximately 0.1 T) into a region with a peak magnetic field of 0.8 T. The energy input per ion-electron pair has been measured at 300 plus or minus 100 eV. Recent results at Oak Ridge National Laboratory (ORNL) show an enhanced efficiency mode of operation with a high power density, over 5 kW in a 5 cm diameter tube. Our helicon is presently 9 cm in diameter and operates up to 3.5 kW of input power. An upgrade to a power level of 10 kW is underway. Much of our recent work has been with a Boswell double-saddle antenna design. We are also converting the antenna design to a helical type. With these modifications, we anticipate an improvement in the ionization efficiency. This paper presents the results from scaling the helicon in the VX-10 device from 3.5 to 10 kW. We also compare the operation with a double-saddle to a helical antenna design. Finally, we

  8. The Materials Science beamline upgrade at the Swiss Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Willmott, P. R., E-mail: philip.willmott@psi.ch; Meister, D.; Leake, S. J.; Lange, M.; Bergamaschi, A. [Swiss Light Source, Paul Scherrer Institut, CH-5232 Villigen (Switzerland); and others

    2013-07-16

    The wiggler X-ray source of the Materials Science beamline at the Swiss Light Source has been replaced with a 14 mm-period cryogenically cooled in-vacuum undulator. In order to best exploit the increased brilliance of this new source, the entire front-end and optics have been redesigned. The Materials Science beamline at the Swiss Light Source has been operational since 2001. In late 2010, the original wiggler source was replaced with a novel insertion device, which allows unprecedented access to high photon energies from an undulator installed in a medium-energy storage ring. In order to best exploit the increased brilliance of this new source, the entire front-end and optics had to be redesigned. In this work, the upgrade of the beamline is described in detail. The tone is didactic, from which it is hoped the reader can adapt the concepts and ideas to his or her needs.

  9. Bright X-ray source from a laser-driven micro-plasma-waveguide

    CERN Document Server

    Yi, Longqing

    2016-01-01

    Bright tunable x-ray sources have a number of applications in basic science, medicine and industry. The most powerful sources are synchrotrons, where relativistic electrons are circling in giant storage rings. In parallel, compact laser-plasma x-ray sources are being developed. Owing to the rapid progress in laser technology, very high-contrast femtosecond laser pulses of relativistic intensities become available. These pulses allow for interaction with micro-structured solid-density plasma without destroying the structure by parasitic pre-pulses. The high-contrast laser pulses as well as the manufacturing of materials at micro- and nano-scales open a new realm of possibilities for laser interaction with photonic materials at the relativistic intensities. Here we demonstrate, via numerical simulations, that when coupling with a readily available 1.8 Joule laser, a micro-plasma-waveguide (MPW) may serve as a novel compact x-ray source. Electrons are extracted from the walls by the laser field and form a dense ...

  10. Charge-exchange source terms in magnetohydrodynamic plasmas

    Science.gov (United States)

    DeStefano, Anthony M.; Heerikhuisen, Jacob

    2017-05-01

    In the modeling of space plasma environments, source terms are often used to couple separate species of particles and/or fluids. There have been many techniques developed over the years to make such coupling more tractable while maintaining maximum physical fidelity. In our current application we use the formalism of the Boltzmann collision integral to compute source terms due to charge-exchange events in the heliosphere. The charge-exchange cross sections often encountered in heliospheric interactions can be fit to laboratory data, but in most cases cannot be directly integrated over analytically. Therefore, researchers often employ various levels of approximation, either semi-analytic or numerical. We explore several assumptions to the charge-exchange source term integrals, namely using Maxwellian velocity spaces for like-mass species and either hard-sphere, power-law, or exact forms of the cross section.

  11. Element Abundances and Source Plasma Temperatures of Solar Energetic Particles

    Science.gov (United States)

    Reames, Donald V.

    2016-11-01

    Thirty years ago Breneman and Stone [1] observed that the enhancement or suppression of element abundances in large solar energetic-particle (SEP) events varies as a power of the mass-to-charge ratio, A/Q, of the elements. Since Q during acceleration or transport may depend upon the source plasma temperature T, the pattern of element enhancements can provide a best-fit measure of T. The small SEP events we call 3He-rich or “impulsive” show average enhancements, relative to coronal abundances, rising as the 3.6 power of A/Q to a factor of ∼1000 for (76magnetic reconnection on open field lines in solar flares and jets. It has been recently found that the large shock-accelerated “gradual” SEP events have a broad range of source plasma temperatures; 69% have coronal temperatures of T seed population containing residual impulsive suprathermal ions. Most of the large event-to-event abundance variations and their time variation are largely explained by variations in T magnified by A/Q-dependent fractionation during transport. However, the non-thermal variance of impulsive SEP events (∼30%) exceeds that of the ∼3 MK gradual events (∼10%) so that several small impulsive events must be averaged together with the ambient plasma to form the seed population for shock acceleration in these events.

  12. Extraction of ions and electrons from audio frequency plasma source

    Directory of Open Access Journals (Sweden)

    N. A. Haleem

    2016-09-01

    Full Text Available Herein, the extraction of high ion / electron current from an audio frequency (AF nitrogen gas discharge (10 – 100 kHz is studied and investigated. This system is featured by its small size (L= 20 cm and inner diameter = 3.4 cm and its capacitive discharge electrodes inside the tube and its high discharge pressure ∼ 0.3 Torr, without the need of high vacuum system or magnetic fields. The extraction system of ion/electron current from the plasma is a very simple electrode that allows self-beam focusing by adjusting its position from the source exit. The working discharge conditions were applied at a frequency from 10 to 100 kHz, power from 50 – 500 W and the gap distance between the plasma meniscus surface and the extractor electrode extending from 3 to 13 mm. The extracted ion/ electron current is found mainly dependent on the discharge power, the extraction gap width and the frequency of the audio supply. SIMION 3D program version 7.0 package is used to generate a simulation of ion trajectories as a reference to compare and to optimize the experimental extraction beam from the present audio frequency plasma source using identical operational conditions. The focal point as well the beam diameter at the collector area is deduced. The simulations showed a respectable agreement with the experimental results all together provide the optimizing basis of the extraction electrode construction and its parameters for beam production.

  13. 77 FR 7 - Revisions to Labeling Requirements for Blood and Blood Components, Including Source Plasma

    Science.gov (United States)

    2012-01-03

    ...) Revisions to Labeling Requirements for Blood and Blood Components, Including Source Plasma AGENCY: Food and... requirements for blood and blood components, including Source Plasma, into one section of the Code of Federal..., and Source Plasma,'' which amended Sec. 606.121(d)(2) by adding ``or in solid black,''...

  14. A compact and continuously driven supersonic plasma and neutral source.

    Science.gov (United States)

    Asai, T; Itagaki, H; Numasawa, H; Terashima, Y; Hirano, Y; Hirose, A

    2010-10-01

    A compact and repetitively driven plasma source has been developed by utilizing a magnetized coaxial plasma gun (MCPG) for diagnostics requiring deep penetration of a large amount of neutral flux. The system consists of a MCPG 95mm in length with a DN16 ConFlat connection port and an insulated gate bipolar transistor (IGBT) inverter power unit. The power supply consists of an array of eight IGBT units and is able to switch the discharge on and off at up to 10 kV and 600 A with a maximum repetitive frequency of 10 kHz. Multiple short duration discharge pulses maximize acceleration efficiency of the plasmoid. In the case of a 10 kHz operating frequency, helium-plasmoids in the velocity range of 20 km/s can be achieved.

  15. Internet and web projects for fusion plasma science and education. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Eastman, Timothy E. [Senior Research Associate, Silver Spring, MD (United States)

    1999-08-30

    The plasma web site at http://www.plasmas.org provides comprehensive coverage of all plasma science and technology with site links worldwide. Prepared to serve the general public, students, educators, researchers, and decision-makers, the site covers basic plasma physics, fusion energy, magnetic confinement fusion, high energy density physics include ICF, space physics and astrophysics, pulsed-power, lighting, waste treatment, plasma technology, plasma theory, simulations and modeling.

  16. Advances and synergy of high pressure sciences at synchrotron sources

    Energy Technology Data Exchange (ETDEWEB)

    Liu, H.; Ehm, L.; Duffy, T.; Crichton, W.; Aoki, K.

    2009-01-01

    Introductory overview to the special issue papers on high-pressure sciences and synchrotron radiation. High-pressure research in geosciences, materials science and condensed matter physics at synchrotron sources is experiencing growth and development through synergistic efforts around the world. A series of high-pressure science workshops were organized in 2008 to highlight these developments. One of these workshops, on 'Advances in high-pressure science using synchrotron X-rays', was held at the National Synchrotron Light Source (NSLS), Brookhaven National Laboratory, USA, on 4 October 2008. This workshop was organized in honour of Drs Jingzhu Hu and Quanzhong Guo in celebration of their retirement after up to 18 years of dedicated service to the high-pressure community as beamline scientists at X17 of NSLS. Following this celebration of the often unheralded role of the beamline scientist, a special issue of the Journal of Synchrotron Radiation on Advances and Synergy of High-Pressure Sciences at Synchrotron Sources was proposed, and we were pleased to invite contributions from colleagues who participated in the workshop as well as others who are making similar efforts at synchrotron sources worldwide.

  17. Minority Preservice Teachers' Conceptions of Teaching Science: Sources of Science Teaching Strategies

    Science.gov (United States)

    Subramaniam, Karthigeyan

    2013-04-01

    This study explores five minority preservice teachers' conceptions of teaching science and identifies the sources of their strategies for helping students learn science. Perspectives from the literature on conceptions of teaching science and on the role constructs used to describe and distinguish minority preservice teachers from their mainstream White peers served as the framework to identify minority preservice teachers' instructional ideas, meanings, and actions for teaching science. Data included drawings, narratives, observations and self-review reports of microteaching, and interviews. A thematic analysis of data revealed that the minority preservice teachers' conceptions of teaching science were a specific set of beliefs-driven instructional ideas about how science content is linked to home experiences, students' ideas, hands-on activities, about how science teaching must include group work and not be based solely on textbooks, and about how learning science involves the concept of all students can learn science, and acknowledging and respecting students' ideas about science. Implications for teacher educators include the need to establish supportive environments within methods courses for minority preservice teachers to express their K-12 experiences and acknowledge and examine how these experiences shape their conceptions of teaching science, and to recognize that minority preservice teachers' conceptions of teaching science reveal the multiple ways through which they see and envision science instruction.

  18. Characteristics and potential applications of an ORNL microwave ECR multicusp plasma ion source

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, C.C.

    1990-01-01

    A new microwave electron cyclotron resonance (ECR) multicusp plasma ion source that has two ECR plasma production regions and uses multicusp plasma confinement has been developed at Oak Ridge National Laboratory. This source has been operated to produce uniform and dense plasma over large areas of 300 to 400 cm{sup 2} and could be scaled up to produce uniform plasma over 700 cm{sup 2} or larger. The plasma source has been operated with continuous argon gas feed and pulsed microwave power. The working gases used were argon, helium, hydrogen, and oxygen. The discharge initiation phenomena and plasma properties have been investigated and studied as functions of the discharge parameters. The discharge characteristics and a hypothetical discharge mechanism for this plasma source are described and discussed. Potential applications, including plasma and ion-beam sources for manufacturing advanced microelectronics, for space electric propulsion, and for fusion research, are discussed. 10 refs., 10 figs.

  19. Nanoscale imaging using a compact laser plasma EUV source

    Science.gov (United States)

    Wachulak, Przemyslaw; Bartnik, Andrzej; Fiedorowicz, Henryk; Kostecki, Jerzy; Jarocki, Roman; Szczurek, Miroslaw; Szczurek, Anna; Feigl, Torsten; Pina, Ladislav

    2012-05-01

    High resolution imaging methods and techniques are currently under development. One of them is an extreme ultraviolet (EUV) microscopy, based on Fresnel zone plates. In this paper a compact, high-repetition, laser-plasma EUV source, emitting quasi-monochromatic radiation at 13.8nm wavelength was used in a desktop EUV transmission microscopy with a spatial (half-pitch) resolution of 50nm. EUV microscopy images of objects with various thicknesses and the spatial resolution measurements using the knife-edge test are presented.

  20. Study of negative ion transport phenomena in a plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Riz, D.; Pamela, J. [Departement de Recherches sur la Fusion Controlee C. E., Cadarache, 13108 St-Paul-lez-Durance Cedex (France)

    1996-07-01

    NIETZSCHE (Negative Ions Extraction and Transport ZSimulation Code for HydrogEn species) is a negative ion (NI) transport code developed at Cadarache. This code calculates NI trajectories using a 3D Monte-Carlo technique, taking into account the main destruction processes, as well as elastic collisions (H{sup {minus}}/H{sup +}) and charge exchanges (H{sup {minus}}/H{sup 0}). It determines the extraction probability of a NI created at a given position. According to the simulations, we have seen that in the case of volume production, only NI produced close to the plasma grid (PG) can be extracted. Concerning the surface production, we have studied how NI produced on the PG and accelerated by the plasma sheath backward into the source could be extracted. We demonstrate that elastic collisions and charge exchanges play an important role, which in some conditions dominates the magnetic filter effect, which acts as a magnetic mirror. NI transport in various conditions will be discussed: volume/surface production, high/low plasmas density, tent filter/transverse filter. {copyright} {ital 1996 American Institute of Physics.}

  1. Study of negative ion transport phenomena in a plasma source

    Science.gov (United States)

    Riz, D.; Paméla, J.

    1996-07-01

    NIETZSCHE (Negative Ions Extraction and Transport ZSimulation Code for HydrogEn species) is a negative ion (NI) transport code developed at Cadarache. This code calculates NI trajectories using a 3D Monte-Carlo technique, taking into account the main destruction processes, as well as elastic collisions (H-/H+) and charge exchanges (H-/H0). It determines the extraction probability of a NI created at a given position. According to the simulations, we have seen that in the case of volume production, only NI produced close to the plasma grid (PG) can be extracted. Concerning the surface production, we have studied how NI produced on the PG and accelerated by the plasma sheath backward into the source could be extracted. We demonstrate that elastic collisions and charge exchanges play an important role, which in some conditions dominates the magnetic filter effect, which acts as a magnetic mirror. NI transport in various conditions will be discussed: volume/surface production, high/low plasmas density, tent filter/transverse filter.

  2. Plasmas, Dielectrics and the Ultrafast: First Science and Operational Experience at FACET

    Energy Technology Data Exchange (ETDEWEB)

    Clarke, C.I.; Adli, E.; Corde, S.; Decker, F.J.; England, R.J.; Erickson, R.; Fisher, A.; Gessner, S.; Hast, C.; Hogan, M.J.; Li, S.Z.; Lipkowitz, N.; Litos, M.; Nosochkov, Y.; Seeman, J.; Sheppard, J.C.; Tudosa, I.; White, G.; Wienands, U.; Woodley, M.; Wu, Z.; /SLAC /UCLA

    2012-09-14

    FACET (Facility for Advanced Accelerator and Experimental Tests) is an accelerator R&D test facility that has been recently constructed at SLAC National Accelerator Laboratory. The facility provides 20 GeV, 3 nC electron beams, short (20 {micro}m) bunches and small (20 {micro}m wide) spot sizes, producing uniquely high power beams. FACET supports studies from many fields but in particular those of Plasma Wakefield Acceleration and Dielectric Wakefield Acceleration. FACET is also a source of THz radiation for material studies. We present the FACET design, initial operating experience and first science from the facility.

  3. Element Abundances and Source Plasma Temperatures of Solar Energetic Particles

    CERN Document Server

    Reames, Donald V

    2016-01-01

    Thirty years ago Breneman and Stone observed that the enhancement or suppression of element abundances in large solar energetic-particle (SEP) events varies as a power of the mass-to-charge ratio, A/Q, of the elements. Since Q during acceleration or transport may depend upon the source plasma temperature T, the pattern of element enhancements can provide a best-fit measure of T. The small SEP events we call 3He-rich or "impulsive" show average enhancements, relative to coronal abundances, rising as the 3.6 power of A/Q to a factor of ~1000 for (76<=Z<=82)/O and temperature in the range 2-4 MK. This acceleration is believed to occur in islands of magnetic reconnection on open field lines in solar flares and jets. It has been recently found that the large shock-accelerated "gradual" SEP events have a broad range of source plasma temperatures; 69% have coronal temperatures of T < 1.6 MK, while 24% have T ~ 3 MK, the latter suggesting a seed population containing residual impulsive suprathermal ions. Mos...

  4. Comet plasma densities deduced from refraction of occulted radio sources

    Energy Technology Data Exchange (ETDEWEB)

    Wright, C.S. (Commonwealth Department of Science, Ionospheric Prediction Service, Narrabri, New South Wales, Australia); Nelson, G.J. (Commonwealth Scientific and Industrial Research Organization, Div. of Radiophysics, Narrabri, New South Wales, Australia)

    1979-04-01

    Observations of the occultation of radio sources by comet plasma tails are used to derive the electron density and density gradients in the tails. Occultations of source Culgoora-1 0300+16 by Comet Kohoutek and of Culgoora-1 2313-14 by Comet West were measured by radioheliograph at 80 MHz. After corrections for ionospheric refraction, a 2 arcmin anomaly was observed in the declination of 0300+16, attributed to refraction by the tail of Comet Kohoutek, while none was observed for Comet West. The maximum electron density in the tail of Comet Kohoutek is calculated to be 2 x 10 to the 4th/cu cm, while that of Comet West is 5 x 10 to the 4th/cu cm, with density gradients of about 0.05 per cu cm per km. The direction of refraction observed suggests that the tail of Kohoutek is either highly asymmetric about its axis or has the form of a hollow, cylindrical plasma sheath. The high electron densities observed in Kohoutek may indicate the presence of undetected ion species or a low ionization loss rate.

  5. The Gridless Plasma Ion Source(GIS)for Plasma Ion Assisted Optical Coating

    Institute of Scientific and Technical Information of China (English)

    尤大伟; 李晓谦; 王宇; 林永昌

    2004-01-01

    High-quality optical coating is a key technology for modern optics. Ion-assisted deposition technology was used to improve the vaporized coating in 1980's. The GIS (gridless ion source), which is an advanced plasma source for producing a high-quality optical coating in large area, can produce a large area uniformity>1000 mm(diameter), a high ion current density ~ 0.5mA/cm2, 20 eV ~ 200 eV energetic plasma ions and can activate reactive gas and film atoms. Now we have developed a GIS system. The GIS and the plasma ion-assisted deposition technology are investigated to achieve a high-quality optical coating. The GIS is a high power and high current source with a power of I kW ~ 7.5 kW, a current of 10 A ~ 70 A and an ion density of 200μA/cm2 ~ 500μA/cm2. Because of the special magnetic structure, the plasma-ion extraction efficiency has been improved to obtain a maximum ion density of 500μA/cm2 in the medium power (~ 4 kW) level. The GIS applied is of a special cathode structure, so that the GIS operation can be maintained under a rather low power and the lifetime of cathode will be extended. The GIS has been installed in the LPSX-1200 type box coating system. The coated TiO2, SiO2 films such as antireflective films with the system have the same performance reported by Leybold Co, 1992, along with a controllable refractive index and film structure.

  6. Media sources, credibility, and perceptions of science: Learning about how people learn about science.

    Science.gov (United States)

    Takahashi, Bruno; Tandoc, Edson C

    2016-08-01

    Knowledge about science and technology has become increasingly important in this age of digital information overload. It is also becoming increasingly important to understand what contributes to scientific learning, including information sources and trust in those sources. In this study, we develop and test a multivariate model to explain scientific knowledge based on past theories on learning from the news from the fields of political communication, sociology, and media psychology. We focus on the impact of sources-by platform, such as television and online, and by expertise, such as scientists and the media-in understanding what predicts scientific knowledge. The results show that interest in science not only directly predicts knowledge but also has indirect effects on knowledge through its effects on Internet use, confidence in the press, and perception of scientists. In addition, distrust on the news sources is an important pathway to learning about science.

  7. A tandem mirror plasma source for a hybrid plume plasma propulsion concept

    Science.gov (United States)

    Yang, T. F.; Miller, R. H.; Wenzel, K. W.; Krueger, W. A.; Chang, F. R.

    1985-01-01

    This paper describes a tandem mirror magnetic plasma confinement device to be considered as a hot plasma source for the hybrid plume rocket concept. The hot plasma from this device is injected into an exhaust duct, which will interact with an annular layer of hypersonic neutral gas. Such a device can be used to study the dynamics of the hybrid plume and to experimentally verify the numerical predictions obtained with computer codes. The basic system design is also geared toward being lightweight and compact, as well as having high power density (i.e., several kW/sq cm) at the exhaust. This feature is aimed toward the feasibility of 'space testing'. The plasma is heated by microwaves. A 50 percent heating efficiency can be obtained by using two half-circle antennas. The preliminary Monte Carlo modeling of test particles result reported here indicates that interaction does take place in the exhaust duct. Neutrals gain energy from the ion, which confirms the hybrid plume concept.

  8. Constructive Use of Authoritative Sources in Science Meaning-making

    Science.gov (United States)

    Yeo, Jennifer; Chee Tan, Seng

    2010-09-01

    Researchers are skeptical about the role of authoritative sources of information in a constructivist learning environment for fear of usurping students' critical thinking. Taking a social semiotics perspective in this study, authoritative sources are regarded as inscriptions of cultural artifacts, and science learning involves meaning-making of these cultural artifacts. In studying the meaning-making process of a group of students doing problem-based learning (PBL), our findings show that authoritative sources played an important role in deepening and expanding students' scientific knowledge. We also found that constructive use of authoritative sources involves interpretation of meaning in context. This structural coupling of authoritative sources and context for meaningful sense-making has to be taken into consideration in the design of learning environment.

  9. Compact tunable Compton x-ray source from laser-plasma accelerator and plasma mirror

    CERN Document Server

    Tsai, Hai-En; Shaw, Joseph; Li, Zhengyan; Arefiev, Alexey V; Zhang, Xi; Zgadzaj, Rafal; Henderson, Watson; Khudik, V; Shvets, G; Downer, M C

    2014-01-01

    We present results of the first tunable Compton backscattering (CBS) x-ray source that is based on the easily aligned combination of a laser-plasma accelerator (LPA) and a plasma mirror (PM). The LPA is driven in the blowout regime by 30 TW, 30 fs laser pulses, and produces high-quality, tunable, quasi-monoenergetic electron beams. A thin plastic film near the gas jet exit efficiently retro-reflects the LPA driving pulse with relativistic intensity into oncoming electrons to produce $2\\times10^{7}$ CBS x-ray photons per shot with 10-20 mrad angular divergence and 50 % (FWHM) energy spread without detectable bremsstrahlung background. The x-ray central energy is tuned from 75 KeV to 200 KeV by tuning the LPA e-beam central energy. Particle-in-cell simulations of the LPA, the drive pulse/PM interaction and CBS agree well with measurements.

  10. GOSH! A roadmap for open-source science hardware

    CERN Multimedia

    Stefania Pandolfi

    2016-01-01

    The goal of the Gathering for Open Science Hardware (GOSH! 2016), held from 2 to 5 March 2016 at IdeaSquare, was to lay the foundations of the open-source hardware for science movement.   The participants in the GOSH! 2016 meeting gathered in IdeaSquare. (Image: GOSH Community) “Despite advances in technology, many scientific innovations are held back because of a lack of affordable and customisable hardware,” says François Grey, a professor at the University of Geneva and coordinator of Citizen Cyberlab – a partnership between CERN, the UN Institute for Training and Research and the University of Geneva – which co-organised the GOSH! 2016 workshop. “This scarcity of accessible science hardware is particularly obstructive for citizen science groups and humanitarian organisations that don’t have the same economic means as a well-funded institution.” Instead, open sourcing science hardware co...

  11. Communicating Science to Impact Learning? A Phenomenological Inquiry into 4th and 5th Graders' Perceptions of Science Information Sources

    Science.gov (United States)

    Gelmez Burakgazi, Sevinc; Yildirim, Ali; Weeth Feinstein, Noah

    2016-04-01

    Rooted in science education and science communication studies, this study examines 4th and 5th grade students' perceptions of science information sources (SIS) and their use in communicating science to students. It combines situated learning theory with uses and gratifications theory in a qualitative phenomenological analysis. Data were gathered through classroom observations and interviews in four Turkish elementary schools. Focus group interviews with 47 students and individual interviews with 17 teachers and 10 parents were conducted. Participants identified a wide range of SIS, including TV, magazines, newspapers, internet, peers, teachers, families, science centers/museums, science exhibitions, textbooks, science books, and science camps. Students reported using various SIS in school-based and non-school contexts to satisfy their cognitive, affective, personal, and social integrative needs. SIS were used for science courses, homework/project assignments, examination/test preparations, and individual science-related research. Students assessed SIS in terms of the perceived accessibility of the sources, the quality of the content, and the content presentation. In particular, some sources such as teachers, families, TV, science magazines, textbooks, and science centers/museums ("directive sources") predictably led students to other sources such as teachers, families, internet, and science books ("directed sources"). A small number of sources crossed context boundaries, being useful in both school and out. Results shed light on the connection between science education and science communication in terms of promoting science learning.

  12. Potential applications of a new microwave ECR (electron cyclotron resonance) multicusp plasma ion source

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, C.C.

    1990-01-01

    A new microwave electron cyclotron resonance (ECR) multicusp plasma ion source using two ECR plasma production regions and multicusp plasma confinement has been developed at Oak Ridge National Laboratory. This source has been operated to produce uniform and dense plasmas over large areas of 300 to 400 cm{sup 2}. The plasma source has been operated with continuous argon gas feed and pulsed microwave power. The discharge initiation phenomena and plasma properties have been investigated and studied as functions of discharge parameters. Together with the discharge characteristics observed, a hypothetical discharge mechanism for this plasma source is reported and discussed. Potential applications, including plasma and ion-beam processing for manufacturing advanced microelectronics and for space electric propulsion, are discussed. 7 refs., 6 figs.

  13. Potential applications of a new microwave ECR multicusp plasma ion source

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, C.C. (Fusion Energy Div., Oak Ridge National Lab., TN (USA))

    1991-05-01

    A new microwave electron cyclotron resonance (ECR) multicusp plasma ion source using two ECR plasma production regions and multicusp plasma confinement has been developed at Oak Ridge National Laboratory. This source has been operated to produce uniform and dense plasmas over large areas of 300-400 cm{sup 2}. The plasma source has been operated with continuous argon gas feed and pulsed microwave power. The discharge initiation phenomena and plasma properties have been investigated and studied as functions of discharge parameters. Together with the discharge characteristics observed, a hypothetical discharge mechanism for this plasma source is reported and discussed. Potential applications, including plasma and ion-beam processing for manufacturing advanced microelectronics and for space electric propulsion, are discussed. (orig.).

  14. Note: Triggering behavior of a vacuum arc plasma source.

    Science.gov (United States)

    Lan, C H; Long, J D; Zheng, L; Dong, P; Yang, Z; Li, J; Wang, T; He, J L

    2016-08-01

    Axial symmetry of discharge is very important for application of vacuum arc plasma. It is discovered that the triggering method is a significant factor that would influence the symmetry of arc discharge at the final stable stage. Using high-speed multiframe photography, the transition processes from cathode-trigger discharge to cathode-anode discharge were observed. It is shown that the performances of the two triggering methods investigated are quite different. Arc discharge triggered by independent electric source can be stabilized at the center of anode grid, but it is difficult to achieve such good symmetry through resistance triggering. It is also found that the triggering process is highly correlated to the behavior of emitted electrons.

  15. Note: Triggering behavior of a vacuum arc plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Lan, C. H., E-mail: lanchaohui@163.com; Long, J. D.; Zheng, L.; Dong, P.; Yang, Z.; Li, J.; Wang, T.; He, J. L. [Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900 (China)

    2016-08-15

    Axial symmetry of discharge is very important for application of vacuum arc plasma. It is discovered that the triggering method is a significant factor that would influence the symmetry of arc discharge at the final stable stage. Using high-speed multiframe photography, the transition processes from cathode-trigger discharge to cathode-anode discharge were observed. It is shown that the performances of the two triggering methods investigated are quite different. Arc discharge triggered by independent electric source can be stabilized at the center of anode grid, but it is difficult to achieve such good symmetry through resistance triggering. It is also found that the triggering process is highly correlated to the behavior of emitted electrons.

  16. MAGNETIC FIELD GRADIENT EFFECTS ON ION FLUX BEHAVIORS IN ECR PLASMA SOURCES

    Institute of Scientific and Technical Information of China (English)

    1998-01-01

    The available electron cyclotron resonance plasma source has been simulated in two-dimensional configuration space (z, r) and three-dimensional velocity space (Vz, Vr Vθ). The simulation is focused on the magnetic field gradient effects on ion flux behaviors in electron cyclotron resonance plasma sources. The simulation results show that, when the magnetic field gradients increase, electron temperature, plasma density, ionization rate, and ion flux in Zdirection would decrease, while ion energy and plasma potential would increase.

  17. Counter-facing plasma focus system as a repetitive and/or long-pulse high energy density plasma source

    Science.gov (United States)

    Aoyama, Yutaka; Nakajima, Mitsuo; Horioka, Kazuhiko

    2009-11-01

    A plasma focus system composed of a pair of counter-facing coaxial plasma guns is proposed as a long-pulse and/or repetitive high energy density plasma source. A proof-of-concept experiment demonstrated that with an assist of breakdown and outer electrode connections, current sheets evolved into a configuration for stable plasma confinement at the center of the electrodes. The current sheets could successively compress and confine the high energy density plasma every half period of the discharge current, enabling highly repetitive light emissions in extreme ultraviolet region with time durations in at least ten microseconds.

  18. A microwave plasma source for VUV atmospheric photochemistry

    Science.gov (United States)

    Tigrine, S.; Carrasco, N.; Vettier, L.; Cernogora, G.

    2016-10-01

    Microwave plasma discharges working at low pressure are nowadays a well-developed technique mainly used to provide radiation at different wavelengths. The aim of this work is to show that those discharges are an efficient windowless vacuum ultra-violet (VUV) photon source for planetary atmospheric photochemistry experiments. To do this, we use a surfatron-type discharge with a neon gas flow in the mbar pressure range coupled to a photochemical reactor. Working in the VUV range allows nitrogen-dominated atmospheres to be focused on (λ  <  100 nm). The experimental setup makes sure that no energy sources (electrons, metastable atoms) other than the VUV photons interact with the reactive medium. Neon has two resonance lines at 73.6 and 74.3 nm that behave differently depending on the pressure or power conditions. In parallel, the VUV photon flux emitted at 73.6 nm has been experimentally estimated in different pressure and power conditions, and varies in a large range between 2  ×  1013 ph s-1 cm-2 and 4  ×  1014 ph s-1 cm-2, which is comparable to a VUV synchrotron photon flux. Our first case study is the atmosphere of Titan and its N2-CH4 atmosphere. With this VUV source, the production of HCN and C2N2, two major Titan compounds, is detected, ensuring the suitability of the source for atmospheric photochemistry experiments.

  19. Integrating Free and Open Source Solutions into Geospatial Science Education

    Directory of Open Access Journals (Sweden)

    Vaclav Petras

    2015-06-01

    Full Text Available While free and open source software becomes increasingly important in geospatial research and industry, open science perspectives are generally less reflected in universities’ educational programs. We present an example of how free and open source software can be incorporated into geospatial education to promote open and reproducible science. Since 2008 graduate students at North Carolina State University have the opportunity to take a course on geospatial modeling and analysis that is taught with both proprietary and free and open source software. In this course, students perform geospatial tasks simultaneously in the proprietary package ArcGIS and the free and open source package GRASS GIS. By ensuring that students learn to distinguish between geospatial concepts and software specifics, students become more flexible and stronger spatial thinkers when choosing solutions for their independent work in the future. We also discuss ways to continually update and improve our publicly available teaching materials for reuse by teachers, self-learners and other members of the GIS community. Only when free and open source software is fully integrated into geospatial education, we will be able to encourage a culture of openness and, thus, enable greater reproducibility in research and development applications.

  20. Inclined slot-excited annular electron cyclotron resonance plasma source for hyperthermal neutral beam generation.

    Science.gov (United States)

    You, H-J; Kim, D-W; Koo, M; Jang, S-O; Jung, Y-H; Hong, S-H; Lee, B-J

    2011-01-01

    An inclined slot-excited antenna (ISLAN) electron cyclotron resonance (ECR) plasma source is newly designed and constructed for higher flux hyperthermal neutral beam (HNB) generation. The developed ISLAN source is modified from vertical slot-excited antenna (VSLAN) source in two aspects: one is the use of inclined slots instead of vertical slots, and the other is a cusp magnetic field configuration rather than a toroidal configuration. Such modifications allow us to have more uniform arrangement of slots and magnets, then enabling plasma generation more uniform and thinner. Moreover, ECR plasma allows higher ionization rate, enabling plasma density higher even in submillitorr pressures, therefore decreasing the collision rate and∕or the reionization rate of the reflected atoms while passing through the plasma, and eventually getting higher flux of HNBs. In this paper, we report the design features and the plasma characteristics of the ISLAN source by doing plasma measurements and electromagnetic simulations. It was found that ISLAN source can be a high potential source for larger flux HNB generation; the source was found to give higher plasma densities and better uniformities than inductively coupled plasma source, particularly in low pressure ranges. Also, it is important that using ISLAN gives easier matching and better stability, i.e., ISLAN shows similar field patterns and good plasma symmetries irrespective of the variations of the mean diameter of the ring resonator and∕or the presence of a limiter or a reflector, and the operating pressures.

  1. Ablation plasma transport using multicusp magnetic field for laser ion source

    Science.gov (United States)

    Takahashi, K.; Umezawa, M.; Uchino, T.; Ikegami, K.; Sasaki, T.; Kikuchi, T.; Harada, N.

    2016-05-01

    We propose a plasma guiding method using multicusp magnetic field to transport the ablation plasma keeping the density for developing laser ion sources. To investigate the effect of guiding using the magnetic field on the ablation plasma, we demonstrated the transport of the laser ablation plasma in the multicusp magnetic field. The magnetic field was formed with eight permanent magnets and arranged to limit the plasma expansion in the radial direction. We investigated the variation of the plasma ion current density and charge distribution during transport in the magnetic field. The results indicate that the plasma is confined in the radial direction during the transport in the multicusp magnetic field.

  2. High Energy Density Science at the Linac Coherent Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Lee, R W

    2007-10-19

    High energy density science (HEDS), as a discipline that has developed in the United States from National Nuclear Security Agency (NNSA)-sponsored laboratory research programs, is, and will remain, a major component of the NNSA science and technology strategy. Its scientific borders are not restricted to NNSA. 'Frontiers in High Energy Density Physics: The X-Games of Contemporary Science' identified numerous exciting scientific opportunities in this field, while pointing to the need for a overarching interagency plan for its evolution. Meanwhile, construction of the first x-ray free-electron laser, the Office-of-Science-funded Linear Coherent Light Source-LCLS: the world's first free electron x-ray laser, with 100-fsec time resolution, tunable x-ray energies, a high rep rate, and a 10 order-of-magnitude increase in brightness over any other x-ray source--led to the realization that the scientific needs of NNSA and the broader scientific community could be well served by an LCLS HEDS endstation employing both short-pulse and high-energy optical lasers. Development of this concept has been well received in the community. NNSA requested a workshop on the applicability of LCLS to its needs. 'High Energy Density Science at the LCLS: NNSA Defense Programs Mission Need' was held in December 2006. The workshop provided strong support for the relevance of the endstation to NNSA strategic requirements. The range of science that was addressed covered a wide swath of the vast HEDS phase space. The unique possibilities provided by the LCLS in areas of intense interest to NNSA Defense Programs were discussed. The areas of focus included warm dense matter and equations of state, hot dense matter, and behavior of high-pressure materials under conditions of high strain-rate and extreme dynamic loading. Development of new and advanced diagnostic techniques was also addressed. This report lays out the relevant science, as brief summaries (Ch. II), expanded

  3. Perspective: The physics, diagnostics, and applications of atmospheric pressure low temperature plasma sources used in plasma medicine

    Science.gov (United States)

    Laroussi, M.; Lu, X.; Keidar, M.

    2017-07-01

    Low temperature plasmas have been used in various plasma processing applications for several decades. But it is only in the last thirty years or so that sources generating such plasmas at atmospheric pressure in reliable and stable ways have become more prevalent. First, in the late 1980s, the dielectric barrier discharge was used to generate relatively large volume diffuse plasmas at atmospheric pressure. Then, in the early 2000s, plasma jets that can launch cold plasma plumes in ambient air were developed. Extensive experimental and modeling work was carried out on both methods and much of the physics governing such sources was elucidated. Starting in the mid-1990s, low temperature plasma discharges have been used as sources of chemically reactive species that can be transported to interact with biological media, cells, and tissues and induce impactful biological effects. However, many of the biochemical pathways whereby plasma affects cells remain not well understood. This situation is changing rather quickly because the field, known today as "plasma medicine," has experienced exponential growth in the last few years thanks to a global research community that engaged in fundamental and applied research involving the use of cold plasma for the inactivation of bacteria, dental applications, wound healing, and the destruction of cancer cells/tumors. In this perspective, the authors first review the physics as well as the diagnostics of the principal plasma sources used in plasma medicine. Then, brief descriptions of their biomedical applications are presented. To conclude, the authors' personal assessment of the present status and future outlook of the field is given.

  4. Quasi-steady carbon plasma source for neutral beam injector.

    Science.gov (United States)

    Koguchi, H; Sakakita, H; Kiyama, S; Shimada, T; Sato, Y; Hirano, Y

    2014-02-01

    Carbon plasma is successfully sustained during 1000 s without any carrier gas in the bucket type ionization chamber with cusp magnetic field. Every several seconds, seed plasmas having ∼3 ms duration time are injected into the ionization chamber by a shunting arch plasma gun. The weakly ionized carbon plasma ejected from the shunting arch is also ionized by 2.45 GHz microwave at the electron cyclotron resonance surface and the plasma can be sustained even in the interval of gun discharges. Control of the gun discharge interval allows to keep high pressure and to sustain the plasma for long duration.

  5. Physics-electrical hybrid model for real time impedance matching and remote plasma characterization in RF plasma sources

    Science.gov (United States)

    Sudhir, Dass; Bandyopadhyay, M.; Chakraborty, A.

    2016-02-01

    Plasma characterization and impedance matching are an integral part of any radio frequency (RF) based plasma source. In long pulse operation, particularly in high power operation where plasma load may vary due to different reasons (e.g. pressure and power), online tuning of impedance matching circuit and remote plasma density estimation are very useful. In some cases, due to remote interfaces, radio activation and, due to maintenance issues, power probes are not allowed to be incorporated in the ion source design for plasma characterization. Therefore, for characterization and impedance matching, more remote schemes are envisaged. Two such schemes by the same authors are suggested in these regards, which are based on air core transformer model of inductive coupled plasma (ICP) [M. Bandyopadhyay et al., Nucl. Fusion 55, 033017 (2015); D. Sudhir et al., Rev. Sci. Instrum. 85, 013510 (2014)]. However, the influence of the RF field interaction with the plasma to determine its impedance, a physics code HELIC [D. Arnush, Phys. Plasmas 7, 3042 (2000)] is coupled with the transformer model. This model can be useful for both types of RF sources, i.e., ICP and helicon sources.

  6. Physics-electrical hybrid model for real time impedance matching and remote plasma characterization in RF plasma sources

    Energy Technology Data Exchange (ETDEWEB)

    Sudhir, Dass, E-mail: dass.sudhir@iter-india.org; Bandyopadhyay, M.; Chakraborty, A. [ITER-India, Institute for Plasma Research, A-29 GIDC, Sec-25, Gandhinagar, 382016 Gujarat (India)

    2016-02-15

    Plasma characterization and impedance matching are an integral part of any radio frequency (RF) based plasma source. In long pulse operation, particularly in high power operation where plasma load may vary due to different reasons (e.g. pressure and power), online tuning of impedance matching circuit and remote plasma density estimation are very useful. In some cases, due to remote interfaces, radio activation and, due to maintenance issues, power probes are not allowed to be incorporated in the ion source design for plasma characterization. Therefore, for characterization and impedance matching, more remote schemes are envisaged. Two such schemes by the same authors are suggested in these regards, which are based on air core transformer model of inductive coupled plasma (ICP) [M. Bandyopadhyay et al., Nucl. Fusion 55, 033017 (2015); D. Sudhir et al., Rev. Sci. Instrum. 85, 013510 (2014)]. However, the influence of the RF field interaction with the plasma to determine its impedance, a physics code HELIC [D. Arnush, Phys. Plasmas 7, 3042 (2000)] is coupled with the transformer model. This model can be useful for both types of RF sources, i.e., ICP and helicon sources.

  7. Physics-electrical hybrid model for real time impedance matching and remote plasma characterization in RF plasma sources.

    Science.gov (United States)

    Sudhir, Dass; Bandyopadhyay, M; Chakraborty, A

    2016-02-01

    Plasma characterization and impedance matching are an integral part of any radio frequency (RF) based plasma source. In long pulse operation, particularly in high power operation where plasma load may vary due to different reasons (e.g. pressure and power), online tuning of impedance matching circuit and remote plasma density estimation are very useful. In some cases, due to remote interfaces, radio activation and, due to maintenance issues, power probes are not allowed to be incorporated in the ion source design for plasma characterization. Therefore, for characterization and impedance matching, more remote schemes are envisaged. Two such schemes by the same authors are suggested in these regards, which are based on air core transformer model of inductive coupled plasma (ICP) [M. Bandyopadhyay et al., Nucl. Fusion 55, 033017 (2015); D. Sudhir et al., Rev. Sci. Instrum. 85, 013510 (2014)]. However, the influence of the RF field interaction with the plasma to determine its impedance, a physics code HELIC [D. Arnush, Phys. Plasmas 7, 3042 (2000)] is coupled with the transformer model. This model can be useful for both types of RF sources, i.e., ICP and helicon sources.

  8. Ferroelectric plasma sources for NDCX-II and heavy ion drivers

    Energy Technology Data Exchange (ETDEWEB)

    Gilson, E.P., E-mail: egilson@pppl.gov [Princeton Plasma Physics Laboratory, Princeton University, P.O. Box 451, Princeton, New Jersey, 08543 (United States); Davidson, R.C.; Efthimion, P.C.; Kaganovich, I.D. [Princeton Plasma Physics Laboratory, Princeton University, P.O. Box 451, Princeton, New Jersey, 08543 (United States); Kwan, J.W.; Lidia, S.M.; Ni, P.A.; Roy, P.K.; Seidl, P.A.; Waldron, W.L. [Lawrence Berkeley National Laboratory, One Cyclotron Road, Berkeley, California, 94720 (United States); Barnard, J.J.; Friedman, A. [Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California, 94550 (United States)

    2014-01-01

    A barium titanate ferroelectric cylindrical plasma source has been developed, tested and delivered for the Neutralized Drift Compression Experiment NDCX-II at Lawrence Berkeley National Laboratory (LBNL). The plasma source design is based on the successful design of the NDCX-I plasma source. A 7 kV pulse applied across the 3.8 mm-thick ceramic cylinder wall produces a large polarization surface charge density that leads to breakdown and plasma formation. The plasma that fills the NDCX-II drift section upstream of the final-focusing solenoid has a plasma number density exceeding 10{sup 10} cm{sup −3} and an electron temperature of several eV. The operating principle of the ferroelectric plasma source are reviewed and a detailed description of the installation plans is presented. The criteria for plasma sources with larger number density will be given, and concepts will be presented for plasma sources for driver applications. Plasma sources for drivers will need to be highly reliable, and operate at several Hz for millions of shots.

  9. Ferroelectric plasma sources for NDCX-II and heavy ion drivers

    Science.gov (United States)

    Gilson, E. P.; Davidson, R. C.; Efthimion, P. C.; Kaganovich, I. D.; Kwan, J. W.; Lidia, S. M.; Ni, P. A.; Roy, P. K.; Seidl, P. A.; Waldron, W. L.; Barnard, J. J.; Friedman, A.

    2014-01-01

    A barium titanate ferroelectric cylindrical plasma source has been developed, tested and delivered for the Neutralized Drift Compression Experiment NDCX-II at Lawrence Berkeley National Laboratory (LBNL). The plasma source design is based on the successful design of the NDCX-I plasma source. A 7 kV pulse applied across the 3.8 mm-thick ceramic cylinder wall produces a large polarization surface charge density that leads to breakdown and plasma formation. The plasma that fills the NDCX-II drift section upstream of the final-focusing solenoid has a plasma number density exceeding 1010 cm-3 and an electron temperature of several eV. The operating principle of the ferroelectric plasma source are reviewed and a detailed description of the installation plans is presented. The criteria for plasma sources with larger number density will be given, and concepts will be presented for plasma sources for driver applications. Plasma sources for drivers will need to be highly reliable, and operate at several Hz for millions of shots.

  10. Design of the plasma grid for a short pulse negative ion source experimental setup at HUST

    Science.gov (United States)

    Zuo, C.; Li, D.; Chen, D.; Zhao, P.; Xu, Q.; Liao, Z.

    2017-08-01

    An experimental setup of a radio frequency (RF) driven negative hydrogen ion source has been developed at Huazhong University of Science and Technology (HUST). The setup without cesium oven and an extraction system had been completed and the plasma was ignited in the driver successfully in 2014. An extraction system with small area (5540 mm2) for short pulse (˜ 4 s) was designed to extract the negative hydrogen ions. Generally, the plasma grid temperature is controlled to reach 150 °C by the cooling channels inside the grid. But another method that we could use the PG current to raise the temperature is being considered only for the short pulse condition. An experiment was introduced to prove the feasibility of this method. A magnetic field produced by current flowing through the plasma grid is required to reduce the electron temperature and suppress the co-extraction electrons. The filter field homogeneity has been studied in detail by finite element method. There have been significant improvements regarding the field homogeneity by means of the grid geometry optimization.

  11. Organization by Gordon Research Conferences of the 2012 Plasma Processing Science Conference 22-27 July 2012

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Jane

    2012-07-27

    The 2012 Gordon Research Conference on Plasma Processing Science will feature a comprehensive program that will highlight the most cutting edge scientific advances in plasma science and technology as well as explore the applications of this nonequilibrium medium in possible approaches relative to many grand societal challenges. Fundamental science sessions will focus on plasma kinetics and chemistry, plasma surface interactions, and recent trends in plasma generation and multi-phase plasmas. Application sessions will explore the impact of plasma technology in renewable energy, the production of fuels from renewable feedstocks and carbon dioxide neutral solar fuels (from carbon dioxide and water), and plasma-enabled medicine and sterilization.

  12. Communicating Science to Impact Learning? A Phenomenological Inquiry into 4th and 5th Graders' Perceptions of Science Information Sources

    Science.gov (United States)

    Gelmez Burakgazi, Sevinc; Yildirim, Ali; Weeth Feinstein, Noah

    2016-01-01

    Rooted in science education and science communication studies, this study examines 4th and 5th grade students' perceptions of science information sources (SIS) and their use in communicating science to students. It combines situated learning theory with uses and gratifications theory in a qualitative phenomenological analysis. Data were gathered…

  13. Communicating Science to Impact Learning? A Phenomenological Inquiry into 4th and 5th Graders' Perceptions of Science Information Sources

    Science.gov (United States)

    Gelmez Burakgazi, Sevinc; Yildirim, Ali; Weeth Feinstein, Noah

    2016-01-01

    Rooted in science education and science communication studies, this study examines 4th and 5th grade students' perceptions of science information sources (SIS) and their use in communicating science to students. It combines situated learning theory with uses and gratifications theory in a qualitative phenomenological analysis. Data were gathered…

  14. Analysis of plasma distribution near the extraction region in surface produced negative ion sources.

    Science.gov (United States)

    Fukano, A; Hatayama, A

    2014-02-01

    In study of a negative ion source, it is important to understand the plasma characteristics near the extraction region. A recent experiment in the NIFS-R&D ion source has suggested that a "double ion plasma layer" which is a region consisting of hydrogen positive and negative ions exists near the plasma grid (PG). Density distribution of plasma near the extraction region is studied analytically. It is shown that the density distribution depends on an amount of the surface produced negative ions and the double ion plasma layer is formed near the PG surface for the case of strong surface production.

  15. Low-Energy Plasma Focus Device as an Electron Beam Source

    Science.gov (United States)

    Seong Ling, Yap; Naresh Kumar, Nitturi; Lian Kuang, Lim; Chiow San, Wong

    2014-01-01

    A low-energy plasma focus device was used as an electron beam source. A technique was developed to simultaneously measure the electron beam intensity and energy. The system was operated in Argon filling at an optimum pressure of 1.7 mbar. A Faraday cup was used together with an array of filtered PIN diodes. The beam-target X-rays were registered through X-ray spectrometry. Copper and lead line radiations were registered upon usage as targets. The maximum electron beam charge and density were estimated to be 0.31 μC and 13.5 × 1016/m3, respectively. The average energy of the electron beam was 500 keV. The high flux of the electron beam can be potentially applicable in material sciences. PMID:25544952

  16. Low-Energy Plasma Focus Device as an Electron Beam Source

    Directory of Open Access Journals (Sweden)

    Muhammad Zubair Khan

    2014-01-01

    Full Text Available A low-energy plasma focus device was used as an electron beam source. A technique was developed to simultaneously measure the electron beam intensity and energy. The system was operated in Argon filling at an optimum pressure of 1.7 mbar. A Faraday cup was used together with an array of filtered PIN diodes. The beam-target X-rays were registered through X-ray spectrometry. Copper and lead line radiations were registered upon usage as targets. The maximum electron beam charge and density were estimated to be 0.31 μC and 13.5×1016/m3, respectively. The average energy of the electron beam was 500 keV. The high flux of the electron beam can be potentially applicable in material sciences.

  17. Source formulation for electron-impact ionization for fluid plasma simulations

    DEFF Research Database (Denmark)

    Müller, S.H.; Holland, C.; Tynan, G.R.;

    2009-01-01

    The derivation of the correct functional form of source terms in plasma fluid theory is revisited. The relation between the fluid source terms and atomic physics differential cross sections is established for particle-impact ionization. It is shown that the interface between atomic and plasma...

  18. Dependence of the source performance on plasma parameters at the BATMAN test facility

    Energy Technology Data Exchange (ETDEWEB)

    Wimmer, C.; Fantz, U. [Max-Planck-Institut für Plasmaphysik, Boltzmannstr. 2, 85748 Garching (Germany)

    2015-04-08

    The investigation of the dependence of the source performance (high j{sub H{sup −}}, low j{sub e}) for optimum Cs conditions on the plasma parameters at the BATMAN (Bavarian Test MAchine for Negative hydrogen ions) test facility is desirable in order to find key parameters for the operation of the source as well as to deepen the physical understanding. The most relevant source physics takes place in the extended boundary layer, which is the plasma layer with a thickness of several cm in front of the plasma grid: the production of H{sup −}, its transport through the plasma and its extraction, inevitably accompanied by the co-extraction of electrons. Hence, a link of the source performance with the plasma parameters in the extended boundary layer is expected. In order to characterize electron and negative hydrogen ion fluxes in the extended boundary layer, Cavity Ring-Down Spectroscopy and Langmuir probes have been applied for the measurement of the H{sup −} density and the determination of the plasma density, the plasma potential and the electron temperature, respectively. The plasma potential is of particular importance as it determines the sheath potential profile at the plasma grid: depending on the plasma grid bias relative to the plasma potential, a transition in the plasma sheath from an electron repelling to an electron attracting sheath takes place, influencing strongly the electron fraction of the bias current and thus the amount of co-extracted electrons. Dependencies of the source performance on the determined plasma parameters are presented for the comparison of two source pressures (0.6 Pa, 0.45 Pa) in hydrogen operation. The higher source pressure of 0.6 Pa is a standard point of operation at BATMAN with external magnets, whereas the lower pressure of 0.45 Pa is closer to the ITER requirements (p ≤ 0.3 Pa)

  19. Dependence of the source performance on plasma parameters at the BATMAN test facility

    Science.gov (United States)

    Wimmer, C.; Fantz, U.

    2015-04-01

    The investigation of the dependence of the source performance (high jH-, low je) for optimum Cs conditions on the plasma parameters at the BATMAN (Bavarian Test MAchine for Negative hydrogen ions) test facility is desirable in order to find key parameters for the operation of the source as well as to deepen the physical understanding. The most relevant source physics takes place in the extended boundary layer, which is the plasma layer with a thickness of several cm in front of the plasma grid: the production of H-, its transport through the plasma and its extraction, inevitably accompanied by the co-extraction of electrons. Hence, a link of the source performance with the plasma parameters in the extended boundary layer is expected. In order to characterize electron and negative hydrogen ion fluxes in the extended boundary layer, Cavity Ring-Down Spectroscopy and Langmuir probes have been applied for the measurement of the H- density and the determination of the plasma density, the plasma potential and the electron temperature, respectively. The plasma potential is of particular importance as it determines the sheath potential profile at the plasma grid: depending on the plasma grid bias relative to the plasma potential, a transition in the plasma sheath from an electron repelling to an electron attracting sheath takes place, influencing strongly the electron fraction of the bias current and thus the amount of co-extracted electrons. Dependencies of the source performance on the determined plasma parameters are presented for the comparison of two source pressures (0.6 Pa, 0.45 Pa) in hydrogen operation. The higher source pressure of 0.6 Pa is a standard point of operation at BATMAN with external magnets, whereas the lower pressure of 0.45 Pa is closer to the ITER requirements (p ≤ 0.3 Pa).

  20. Plasma ignition schemes for the SNS radio-frequency driven H- source

    Energy Technology Data Exchange (ETDEWEB)

    Schenkel, T.; Staples, J.W.; Thomae, W.; Reijonen, J.; Gough, R.A.; Leung, K.N.; Keller, R.

    2001-09-06

    The H{sup -} ion source for the Spallation Neutron Source (SNS) is a cesiated, radio-frequency driven (2 MHz) multicusp volume source which operates at a duty cycle of 6% (1 ms pulses and 60 Hz). In pulsed RF driven plasma sources, ignition of the plasma affects the stability of source operation and the antenna lifetime. We are reporting on investigations of different ignition schemes, based on secondary electron generation in the plasma chamber by UV light, a hot filament, a low power RF plasma (cw, 13.56 MHz), as well as source operation solely with the high power (40 kW) 2 MHz RF. We find that the dual frequency, single antenna scheme is most attractive for the operating conditions of the SNS H{sup -} source.

  1. Color Developing Capacity of Plasma-treated Water as a Source of Nitrite for Meat Curing

    OpenAIRE

    2015-01-01

    The interaction of plasma with liquid generates nitrogen species including nitrite (NO− 2). Therefore, the color developing capacity of plasma-treated water (PTW) as a nitrite source for meat curing was investigated in this study. PTW, which is generated by surface dielectric barrier discharge in air, and the increase of plasma treatment time resulted in increase of nitrite concentration in PTW. The PTW used in this study contains 46 ppm nitrite after plasma treatment for 30 min. To evaluate ...

  2. The technology and science of steady-state operation in magnetically confined plasmas

    Science.gov (United States)

    Bécoulet, A.; Hoang, G. T.

    2008-12-01

    The steady-state operation of magnetically confined fusion plasmas is considered as one of the 'grand challenges' of future decades, if not the ultimate goal of the research and development activities towards a new source of energy. Reaching such a goal requires the high-level integration of both science and technology aspects of magnetic fusion into self-consistent plasma regimes in fusion-grade devices. On the physics side, the first constraint addresses the magnetic confinement itself which must be made persistent. This means to either rely on intrinsically steady-state configurations, like the stellarator one, or turn the inductively driven tokamak configuration into a fully non-inductive one, through a mix of additional current sources. The low efficiency of the external current drive methods and the necessity to minimize the re-circulating power claim for a current mix strongly weighted by the internal 'pressure driven' bootstrap current, itself strongly sensitive to the heat and particle transport properties of the plasma. A virtuous circle may form as the heat and particle transport properties are themselves sensitive to the current profile conditions. Note that several other factors, e.g. plasma rotation profile, magneto-hydro-dynamics activity, also influence the equilibrium state. In the present tokamak devices, several examples of such 'advanced tokamak' physics research demonstrate the feasibility of steady-state regimes, though with a number of open questions still under investigation. The modelling activity also progresses quite fast in this domain and supports understanding and extrapolation. This high level of physics sophistication of the plasma scenario however needs to be combined with steady-state technological constraints. The technology constraints for steady-state operation are basically twofold: the specific technologies required to reach the steady-state plasma conditions and the generic technologies linked to the long pulse operation of a

  3. A narrow-band, variable energy ion source derived from a wire plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Gueroult, R; Elias, P Q; Packan, D [ONERA Palaiseau, 91761 Palaiseau (France); Rax, J M, E-mail: renaud.gueroult@polytechnique.edu [LPP, Ecole Polytechnique, 91128 Palaiseau Cedex (France)

    2011-08-15

    A low pressure wire-induced plasma source (WIPS) operated in its high-pressure mode ({approx}10{sup -2} mbar) exhibits a narrow ion energy distribution function peaked at an energy corresponding to the discharge voltage. In order to take advantage of this peculiar feature, we design an electrode geometry enabling the acceleration of ions extracted from a WIPS. Probing of the obtained ion plume by means of a retarding potential analyser (RPA) demonstrates the capability of such an ion source to generate narrow-band (full width at half maximum of about 20 eV), variable energy (1 to 5 keV) ion beams. Comparison with particle-in-cell simulations of the WIPS shows that the energy spread of these ion beams is actually about 10 eV, the slight broadening being mainly the effect of the limited planar RPA energy resolution. The ion beam spot size measured at 6 cm of the ion source exit is about 3 mm for a 10 {mu}A He{sup +} beam at 2 keV, with a divergence of about one degree. Operating the WIPS in argon and xenon leads to similar properties for Ar{sup +} and Xe{sup +} beams, and in principle other species could also be used.

  4. A multifunctional plasma and deposition sensor for the characterization of plasma sources for film deposition and etching

    Science.gov (United States)

    Weise, Michael; Seeger, Stefan; Harbauer, Karsten; Welzel, Thomas; Ellmer, Klaus

    2017-07-01

    Our recently reported multifunctional plasma and deposition sensor [Welzel et al., Appl. Phys. Lett. 102, 211605 (2013)] was used for the characterization of two different plasma sources: a magnetron sputtering deposition source and an ion beam source. The multifunctional sensor, based on a conventional quartz crystal monitor (microbalance) for mass increase/decrease measurements, can measure quasi-simultaneously the deposition/etching flux, the energy flux, and the charged particle flux. By moving the sensor or the plasma source stepwise against each other, the lateral (radial) flux profiles of the different sources can be measured with a lateral resolution of about 8 mm, the diameter of aperture in front of the quartz crystal. It is demonstrated that this compact and simple multifunctional sensor is a versatile tool for the characterization of different kinds of plasma sources for deposition and etching purposes. By combining the different measured quantities, the ion-to-neutral ratio and the mean energy per deposited atom can be calculated, parameters that are essential for the characterization of plasma deposition and etch processes.

  5. Science and Technology of Future Light Sources: A White Paper

    Energy Technology Data Exchange (ETDEWEB)

    Bergmann, Uwe; Corlett, John; Dierker, Steve; Falcone, Roger; Galayda, John; Gibson, Murray; Hastings, Jerry; Hettel, Bob; Hill, John; Hussain, Zahid; Kao, Chi-Chang; Kirz, a= Janos; Long, Gabrielle; McCurdy, Bill; Raubenheimer, Tor; Sannibale, Fernando; Seeman, John; Shen, Z.-X.; Shenoy, Gopal; Schoenlein, Bob; Shen, Qun; /Argonne /Brookhaven /LBL, Berkeley /SLAC, SSRL

    2009-02-03

    Many of the important challenges facing humanity, including developing alternative sources of energy and improving health, are being addressed by advances that demand the improved understanding and control of matter. While the visualization, exploration, and manipulation of macroscopic matter have long been technological goals, scientific developments in the twentieth century have focused attention on understanding matter on the atomic scale through the underlying framework of quantum mechanics. Of special interest is matter that consists of natural or artificial nanoscale building blocks defined either by atomic structural arrangements or by electron or spin formations created by collective correlation effects (Figure 1.1). The essence of the challenge to the scientific community has been expressed in five grand challenges for directing matter and energy recently formulated by the Basic Energy Sciences Advisory Committee [1]. These challenges focus on increasing our understanding of, and ultimately control of, matter at the level of atoms, electrons. and spins, as illustrated in Figure 1.1, and serve the entire range of science from advanced materials to life sciences. Meeting these challenges will require new tools that extend our reach into regions of higher spatial, temporal, and energy resolution. X-rays with energies above 10 keV offer capabilities extending beyond the nanoworld shown in Figure 1.1 due to their ability to penetrate into optically opaque or thick objects. This opens the door to combining atomic level information from scattering studies with 3D information on longer length scales from real space imaging with a resolution approaching 1 nm. The investigation of multiple length scales is important in hierarchical structures, providing knowledge about function of living organisms, the atomistic origin of materials failure, the optimization of industrial synthesis, or the working of devices. Since the fundamental interaction that holds matter

  6. Advanced plasma flow simulations of cathodic-arc and ferroelectric plasma sources for neutralized drift compression experiments

    Directory of Open Access Journals (Sweden)

    Adam B. Sefkow

    2008-07-01

    Full Text Available Large-space-scale and long-time-scale plasma flow simulations are executed in order to study the spatial and temporal evolution of plasma parameters for two types of plasma sources used in the neutralized drift compression experiment (NDCX. The results help assess the charge neutralization conditions for ion beam compression experiments and can be employed in more sophisticated simulations, which previously neglected the dynamical evolution of the plasma. Three-dimensional simulations of a filtered cathodic-arc plasma source show the coupling efficiency of the plasma flow from the source to the drift region depends on geometrical factors. The nonuniform magnetic topology complicates the well-known general analytical considerations for evaluating guiding-center drifts, and particle-in-cell simulations provide a self-consistent evaluation of the physics in an otherwise challenging scenario. Plasma flow profiles of a ferroelectric plasma source demonstrate that the densities required for longitudinal compression experiments involving ion beams are provided over the drift length, and are in good agreement with measurements. Simulations involving azimuthally asymmetric plasma creation conditions show that symmetric profiles are nevertheless achieved at the time of peak on-axis plasma density. Also, the ferroelectric plasma expands upstream on the thermal expansion time scale, and therefore avoids the possibility of penetration into the acceleration gap and transport sections, where partial neutralization would increase the beam emittance. Future experiments on NDCX will investigate the transverse focusing of an axially compressing intense charge bunch to a sub-mm spot size with coincident focal planes using a strong final-focus solenoid. In order to fill a multi-tesla solenoid with the necessary high-density plasma for beam charge neutralization, the simulations predict that supersonically injected plasma from the low-field region will penetrate and

  7. PREFACE: 11th Asia-Pacific Conference on Plasma Science and Technology (APCPST-11) and 25th Symposium on Plasma Science for Materials (SPSM-25)

    Science.gov (United States)

    Watanabe, Takayuki; Kaneko, Toshio; Sekine, Makoto; Tanaka, Yasunori

    2013-06-01

    The 11th Asia-Pacific Conference on Plasma Science and Technology (APCPST-11) was held in Kyoto, Japan on 2-5 October 2012 with the 25th Symposium on Plasma Science for Materials (SPSM-25). SPSM has been held annually since 1988 under the sponsorship of The 153rd Committee on Plasma Materials Science, Japan Society for the Promotion of Science (JSPS). This symposium is one of the major activities of the Committee, which is organized by researchers in academia and industry for the purpose of advancing intersectional scientific information exchange and discussion of science and technology of plasma materials processing. APCPST and SPSM are jointly held biennially to survey the current status of low temperature and thermal plasma physics and chemistry for industrial applications. The whole area of plasma processing was covered from fundamentals to applications. Previous meetings were held in China, Japan, Korea, and Australia, attended by scientists from the Asia-Pacific and other countries. The joint conference was organized in plenary lectures, invited, contributed oral presentations and poster sessions. At this meeting, we had 386 participants from 10 countries and 398 presentations, including 26 invited presentations. This year, we arranged special topical sessions that covered green innovation, life innovation, and technical reports from industry. This conference seeks to bring the plasma community together and to create a forum for discussing the latest developments and issues, the challenges ahead in the field of plasma research and applications among engineers and scientists in Asia, the Pacific Rim, as well as Europe. This volume presents 44 papers that were selected via a strict peer-review process from full papers submitted for the proceedings of the conference. The topics range from the basic physics and chemistry of plasma processing to a broad variety of materials processing and environmental applications. This volume offers an overview of recent

  8. Neutron generator for BNCT based on high current ECR ion source with gyrotron plasma heating.

    Science.gov (United States)

    Skalyga, V; Izotov, I; Golubev, S; Razin, S; Sidorov, A; Maslennikova, A; Volovecky, A; Kalvas, T; Koivisto, H; Tarvainen, O

    2015-12-01

    BNCT development nowadays is constrained by a progress in neutron sources design. Creation of a cheap and compact intense neutron source would significantly simplify trial treatments avoiding use of expensive and complicated nuclear reactors and accelerators. D-D or D-T neutron generator is one of alternative types of such sources for. A so-called high current quasi-gasdynamic ECR ion source with plasma heating by millimeter wave gyrotron radiation is suggested to be used in a scheme of D-D neutron generator in the present work. Ion source of that type was developed in the Institute of Applied Physics of Russian Academy of Sciences (Nizhny Novgorod, Russia). It can produce deuteron ion beams with current density up to 700-800 mA/cm(2). Generation of the neutron flux with density at the level of 7-8·10(10) s(-1) cm(-2) at the target surface could be obtained in case of TiD2 target bombardment with deuteron beam accelerated to 100 keV. Estimations show that it is enough for formation of epithermal neutron flux with density higher than 10(9) s(-1) cm(-2) suitable for BNCT. Important advantage of described approach is absence of Tritium in the scheme. First experiments performed in pulsed regime with 300 mA, 45 kV deuteron beam directed to D2O target demonstrated 10(9) s(-1) neutron flux. This value corresponds to theoretical estimations and proofs prospects of neutron generator development based on high current quasi-gasdynamic ECR ion source.

  9. Cold plasma source for bacterial inactivation at atmospheric pressure

    DEFF Research Database (Denmark)

    Chen, Weifeng; Stamate, Eugen; Mejlholm, Ole

    plasma treatment conditions (e.g. power, frequency, time). Preliminary experiments were also performed to evaluate the eect of plasma treatment time on the reduction of the concentration of microorganisms (Lactobacillus sakei and Photobacterium phosphoreum) on inoculated slides of Long & Hammer agar...

  10. Cold plasma source for bacterial inactivation at atmospheric pressure

    DEFF Research Database (Denmark)

    Chen, Weifeng; Stamate, Eugen; Mejlholm, Ole

    A dielectric-barrier discharge system for cold plasma production was built for bacterial inactivation purpose. The eect of cold plasma treatment on sensory properties of seafood products was studied to establish how the sensory properties (e.g. appearance, texture) of seafood were aected by dierent....... The results show that the concentration of Lb. sakei on agar slides was reduced signicantly (P cold plasma for 120 seconds. Treatment of agar slides with cold plasma for 60 seconds was sucient to reduce the concentration of P. phosphoreum to below the detection limit......, corresponding to a reduction of > 4-5 log (cfu/g). Further studies are need on the eect of cold plasma treatments on sensory properties of cold-smoked salmon...

  11. An Electrothermal Plasma Source Developed for Simulation of Transient Heat Loads in Future Large Fusion Devices

    Science.gov (United States)

    Gebhart, Trey; Baylor, Larry; Winfrey, Leigh

    2016-10-01

    The realization of fusion energy requires materials that can withstand high heat and particle fluxes at the plasma material interface. In this work, an electrothermal (ET) plasma source has been designed as a possible transient heat flux source for a linear plasma material interaction device. An ET plasma source operates in the ablative arc regime, which is driven by a DC capacitive discharge. The current travels through the 4mm bore of a boron nitride liner and subsequently ablates and ionizes the liner material. This results in a high density plasma with a large unidirectional bulk flow out of the source exit. The pulse length for the ET source has been optimized using a pulse forming network to have a duration of 1ms at full-width half maximum. The peak currents and maximum source energies seen in this system are 2kA and 5kJ. The goal of this work is to show that the ET source produces electron densities and heat fluxes that are comparable to transient events in future large magnetic confinement fusion devices. Heat flux, plasma temperature, and plasma density were determined for each test shot using infrared imaging and optical spectroscopy techniques. This work will compare the ET source output (heat flux, temperature, and density) with and without an applied magnetic field. Research sponsored by the Laboratory Directed Research and Development Program of Oak Ridge National Laboratory, managed by UT-Battelle, LLC, for the U. S. Department of Energy.

  12. The minimization of non-equilibrium plasma source at high pressure

    Institute of Scientific and Technical Information of China (English)

    BAI MinDi; QIU XiuMei; LIU Dong; YANG Bo; ZHOU JianGang; XUE XiaoHong; GU JianLong

    2008-01-01

    The density of plasma produced by atmospheric non-equilibrium plasma source is the function of en-ergy dissipation rate in ionization electric field and gas particles momentum. The experiment shows that the plasma density highly rises with the increasing of energy dissipation rate and gas particles momentum. When the energy dissipation rate of activation field is 2.18 Wh/m3 and the average gas particles momentum is 109×10-22 g·m/s, the air throughput of plasma source whose volume is only 2.5 cm3 can be up to 12 m3/h and the density of plasma can be up to 1010 cm-3. The research can develop a method of producing minitype plasma source which is low energy consumption but high ion concert-tration used for chemical industry, environmental engineering and military.

  13. Electromagnetic, complex image model of a large area RF resonant antenna as inductive plasma source

    Science.gov (United States)

    Guittienne, Ph; Jacquier, R.; Howling, A. A.; Furno, I.

    2017-03-01

    A large area antenna generates a plasma by both inductive and capacitive coupling; it is an electromagnetically coupled plasma source. In this work, experiments on a large area planar RF antenna source are interpreted in terms of a multi-conductor transmission line coupled to the plasma. This electromagnetic treatment includes mutual inductive coupling using the complex image method, and capacitive matrix coupling between all elements of the resonant network and the plasma. The model reproduces antenna input impedance measurements, with and without plasma, on a 1.2× 1.2 m2 antenna used for large area plasma processing. Analytic expressions are given, and results are obtained by computation of the matrix solution. This method could be used to design planar inductive sources in general, by applying the termination impedances appropriate to each antenna type.

  14. An ultracompact X-ray source based on a laser-plasma undulator.

    Science.gov (United States)

    Andriyash, I A; Lehe, R; Lifschitz, A; Thaury, C; Rax, J-M; Krushelnick, K; Malka, V

    2014-08-22

    The capability of plasmas to sustain ultrahigh electric fields has attracted considerable interest over the last decades and has given rise to laser-plasma engineering. Today, plasmas are commonly used for accelerating and collimating relativistic electrons, or to manipulate intense laser pulses. Here we propose an ultracompact plasma undulator that combines plasma technology and nanoengineering. When coupled with a laser-plasma accelerator, this undulator constitutes a millimetre-sized synchrotron radiation source of X-rays. The undulator consists of an array of nanowires, which are ionized by the laser pulse exiting from the accelerator. The strong charge-separation field, arising around the wires, efficiently wiggles the laser-accelerated electrons. We demonstrate that this system can produce bright, collimated and tunable beams of photons with 10-100 keV energies. This concept opens a path towards a new generation of compact synchrotron sources based on nanostructured plasmas.

  15. Design of a high particle flux hydrogen helicon plasma source for used in plasma materials interaction studies

    Energy Technology Data Exchange (ETDEWEB)

    Goulding, Richard Howell [ORNL; Chen, Guangye [ORNL; Meitner, Steven J [ORNL; Baity Jr, F Wallace [ORNL; Caughman, John B [ORNL; Owen, Larry W [ORNL

    2009-01-01

    Existing linear plasma materials interaction (PMI) facilities all use plasma sources with internal electrodes. An rf-based helicon source is of interest because high plasma densities can be generated with no internal electrodes, allowing true steady state operation with minimal impurity generation. Work has begun at Oak Ridge National Laboratory (ORNL) to develop a large (15 cm) diameter helicon source producing hydrogen plasmas with parameters suitable for use in a linear PMI device: n(e) >= 10(19)m(-3), T(e) = 4-10 eV, particle flux Gamma(p) > 10(23) m(-3) s(-1), and magnetic field strength |B| up to I T in the source region. The device, whose design is based on a previous hydrogen helicon source operated at ORNL[1], will operate at rf frequencies in the range 10 - 26 MHz, and power levels up to similar to 100 kW. Limitations in cooling will prevent operation for pulses longer than several seconds, but a major goal will be the measurement of power deposition on device structures so that a later steady state version can be designed. The device design, the diagnostics to be used, and results of rf modeling of the device will be discussed. These include calculations of plasma loading, resulting currents and voltages in antenna structures and the matching network, power deposition profiles, and the effect of high |B| operation on power absorption.

  16. A plasma source driven predator-prey like mechanism as a potential cause of spiraling intermittencies in linear plasma devices

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, D. [Research Center Jülich GmbH, Institute for Energy and Climate Research—Plasma Physics, D-52425 Jülich (Germany); Ohno, N. [Department of Energy Engineering and Science, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Tanaka, H. [National Institute for Fusion Science, Toki 509-5292 (Japan); Vela, L. [Physics Department, Universidad Carlos III de Madrid, Avda de la Universidad 30, 28911-Leganés, Madrid (Spain)

    2014-03-15

    Three-dimensional global drift fluid simulations are carried out to analyze coherent plasma structures appearing in the NAGDIS-II linear device (nagoya divertor plasma Simulator-II). The numerical simulations reproduce several features of the intermittent spiraling structures observed, for instance, statistical properties, rotation frequency, and the frequency of plasma expulsion. The detailed inspection of the three-dimensional plasma dynamics allows to identify the key mechanism behind the formation of these intermittent events. The resistive coupling between electron pressure and parallel electric field in the plasma source region gives rise to a quasilinear predator-prey like dynamics where the axisymmetric mode represents the prey and the spiraling structure with low azimuthal mode number represents the predator. This interpretation is confirmed by a reduced one-dimensional quasilinear model derived on the basis of the findings in the full three-dimensional simulations. The dominant dynamics reveals certain similarities to the classical Lotka-Volterra cycle.

  17. A plasma source driven predator-prey like mechanism as a potential cause of spiraling intermittencies in linear plasma devices

    Science.gov (United States)

    Reiser, D.; Ohno, N.; Tanaka, H.; Vela, L.

    2014-03-01

    Three-dimensional global drift fluid simulations are carried out to analyze coherent plasma structures appearing in the NAGDIS-II linear device (nagoya divertor plasma Simulator-II). The numerical simulations reproduce several features of the intermittent spiraling structures observed, for instance, statistical properties, rotation frequency, and the frequency of plasma expulsion. The detailed inspection of the three-dimensional plasma dynamics allows to identify the key mechanism behind the formation of these intermittent events. The resistive coupling between electron pressure and parallel electric field in the plasma source region gives rise to a quasilinear predator-prey like dynamics where the axisymmetric mode represents the prey and the spiraling structure with low azimuthal mode number represents the predator. This interpretation is confirmed by a reduced one-dimensional quasilinear model derived on the basis of the findings in the full three-dimensional simulations. The dominant dynamics reveals certain similarities to the classical Lotka-Volterra cycle.

  18. Introduction to Plasma Technology Science, Engineering and Applications

    CERN Document Server

    Harry, John Ernest

    2011-01-01

    Written by a university lecturer with more than forty years experience in plasma technology, this book adopts a didactic approach in its coverage of the theory, engineering and applications of technological plasmas. The theory is developed in a unified way to enable brevity and clarity, providing readers with the necessary background to assess the factors that affect the behavior of plasmas under different operating conditions. The major part of the book is devoted to the applications of plasma technology and their accompanying engineering aspects, classified by the various pressure and densit

  19. Ion angular distribution in plasma of vacuum arc ion source with composite cathode and elevated gas pressure.

    Science.gov (United States)

    Nikolaev, A G; Savkin, K P; Yushkov, G Yu; Oks, E M

    2014-02-01

    The Metal Vapor Vacuum Arc (MEVVA) ion sources are capable of generating ion beams of almost all metals of the periodic table. For this kind of ion source, a combination of gas feeding with magnetic field allows the simultaneous generation of both metal and gaseous ions. That makes the MEVVA ion source an excellent instrument for science and application. This work presents results of investigation for ion angular distributions in vacuum arc plasma of Mevva-V.Ru ion source for composite cathodes and for elevated gas pressure. It was shown that for all the cathode materials, singly charged ions have wider angular distribution than multiply charged ions. Increasing the working gas pressure leads to a significant change in the angular distribution of gaseous ions, while with the distribution of metal ions gas remains practically unchanged. The reasons for such different influences are discussed.

  20. PROMETHEUS-A: A helicon plasma source for future wakefield accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Buttenschoen, Birger; Fahrenkamp, Nils; Grulke, Olaf [Max Planck Institute for Plasma Physics, Wendelsteinstr. 1, 17491 Greifswald (Germany)

    2015-05-01

    High density plasma sources are of interest for a wide range of applications like plasma-wall interaction studies, plasma thrusters for space propulsion, or future plasma wakefield particle accelerators. In this contribution, we present a high power helicon cell designed for the world's first proton-beam driven plasma wakefield accelerator experiment AWAKE. Using a modular concept with four antennas distributed along a one meter long, five centimeter diameter prototype module providing up to 35 kW of rf power to the plasma, accelerator relevant densities of 6 . 10{sup 20} m{sup -3} are transiently achieved and exceeded. These high density plasmas are characterized for the use with wakefield accelerators, considering density evolution and its reproducibility, plasma profiles and neutral gas inventory.

  1. Plasma ignition and steady state simulations of the Linac4 H$^{-}$ ion source

    CERN Document Server

    Mattei, S; Yasumoto, M; Hatayama, A; Lettry, J; Grudiev, A

    2014-01-01

    The RF heating of the plasma in the Linac4 H- ion source has been simulated using an Particle-in-Cell Monte Carlo Collision method (PIC-MCC). This model is applied to investigate the plasma formation starting from an initial low electron density of 1012 m-3 and its stabilization at 1018 m-3. The plasma discharge at low electron density is driven by the capacitive coupling with the electric field generated by the antenna, and as the electron density increases the capacitive electric field is shielded by the plasma and induction drives the plasma heating process. Plasma properties such as e-/ion densities and energies, sheath formation and shielding effect are presented and provide insight to the plasma properties of the hydrogen plasma.

  2. QSARs for Plasma Protein Binding: Source Data and Predictions

    Data.gov (United States)

    U.S. Environmental Protection Agency — The dataset has all of the information used to create and evaluate 3 independent QSAR models for the fraction of a chemical unbound by plasma protein (Fub) for...

  3. Brilliant radiation sources by laser-plasma accelerators and optical undulators

    Energy Technology Data Exchange (ETDEWEB)

    Debus, Alexander

    2012-09-06

    This thesis investigates the use of high-power lasers for synchrotron radiation sources with high brilliance, from the EUV to the hard X-ray spectral range. Hereby lasers accelerate electrons by laser-wakefield acceleration (LWFA), act as optical undulators, or both. Experimental evidence shows for the first time that LWFA electron bunches are shorter than the driving laser and have a length scale comparable to the plasma wavelength. Furthermore, a first proof of principle experiment demonstrates that LWFA electrons can be exploited to generate undulator radiation. Building upon these experimental findings, as well as extensive numerical simulations of Thomson scattering, the theoretical foundations of a novel interaction geometry for laser-matter interaction are developed. This new method is very general and when tailored towards relativistically moving targets not being limited by the focusability (Rayleigh length) of the laser, while it does not require a waveguide. In a theoretical investigation of Thomson scattering, the optical analogue of undulator radiation, the limits of Thomson sources in scaling towards higher peak brilliances are highlighted. This leads to a novel method for generating brilliant, highly tunable X-ray sources, which is highly energy efficient by circumventing the laser Rayleigh limit through a novel traveling-wave Thomson scattering (TWTS) geometry. This new method suggests increases in X-ray photon yields of 2-3 orders of magnitudes using existing lasers and a way towards efficient, optical undulators to drive a free-electron laser. The results presented here extend far beyond the scope of this work. The possibility to use lasers as particle accelerators, as well as optical undulators, leads to very compact and energy efficient synchrotron sources. The resulting monoenergetic radiation of high brilliance in a range from extreme ultraviolet (EUV) to hard X-ray radiation is of fundamental importance for basic research, medical

  4. PLASMOSE - antimicrobial effects of modular atmospheric plasma sources

    OpenAIRE

    Ehlbeck, J; Van Brandenburg, R; von Woedtke, T; Krohmann, U; Stieber, M.; Weltmann, KD

    2008-01-01

    The technological potential of non-thermal plasmas for the antimicrobial treatment of heat sensitive materials is well known and has been documented in a great number of research activities, but the realisation of industrial plasma-based decontamination processes remains a great challenge. One of the reasons for this situation is the fact that an antimicrobial treatment process needs to consider all properties of the product to be treated as well as the requirements of the complete procedure,...

  5. Advanced Laser and RF Plasma Sources and Diagnostics

    Science.gov (United States)

    2007-06-13

    jacks, fibers, collimators, and breadboards $19,832.71 Interferometry Gunn diode and I-Q mixer $6,775.00 RF Components and Automation High...temperature diagnostics for both our laser window and radiofrequency air plasmas. We have also acquired a tunable 668 nm diode laser, optical filters...diagnostics for both our laser window and radiofrequency air plasmas. We have also acquired a tunable 668 nm diode laser, optical filters, splitters

  6. PREFACE: 26th Symposium on Plasma Science for Materials (SPSM-26)

    Science.gov (United States)

    2014-06-01

    26th Symposium on Plasma Science for Materials (SPSM-26) Takayuki Watanabe The 26th Symposium on Plasma Science for Materials (SPSM-26) was held in Fukuoka, Japan on September 23-24, 2013. SPSM has been held annually since 1988 under the sponsorship of The 153rd Committee on Plasma Materials Science, Japan Society for the Promotion of Science (JSPS). This symposium is one of the major activities of the Committee, which is organized by researchers in academia and industry for the purpose of advancing intersectional scientific information exchange and discussion of science and technology of plasma materials processing. Plasma processing have attracted extensive attention due to their unique advantages, and it is expected to be utilized for a number of innovative industrial applications such as synthesis of high-quality and high-performance nanomaterials. The advantages of plasmas including high chemical reactivity in accordance with required chemical reactions are beneficial for innovative processing. In recent years, plasma materials processing with reactive plasmas has been extensively employed in the fields of environmental issues and biotechnology. This conference seeks to bring different scientific communities together to create a forum for discussing the latest developments and issues. The conference provides a platform for the exploration of both fundamental topics and new applications of plasmas by the contacts between science, technology, and industry. The conference was organized in plenary lectures, invited, contributed oral presentations, and poster sessions. At this meeting, we had 142 participants from 10 countries and 104 presentations, including 11 invited presentations. This year, we arranged special topical sessions that cover Plasma Medicine and Biotechnologies, Business and Academia Cooperation, Plasma with Liquids, Plasma Processes for Nanomaterials, together with Basic, Electronics, and Thermal Plasma sessions. This special issue presents 28

  7. First results with a surface conversion H ion source based on helicon wave mode-driven plasma discharge

    Energy Technology Data Exchange (ETDEWEB)

    Tarvainen, Ollie A [Los Alamos National Laboratory; Geros, Ernest [Los Alamos National Laboratory; Rouleau, Gary [Los Alamos National Laboratory; Zaugg, Thomas J [Los Alamos National Laboratory

    2008-01-01

    The currently employed converter-type negative ion source at Los Alamos Neutron Science Center (LANSCE) is based on cesium enhanced surface production of H{sup -} ion beams in a filament-driven discharge. The extracted H{sup -} beam current is limited by the achievable plasma density, which depends primarily on the electron emission current from the filaments. The emission current can be increased by increasing the filament temperature but, unfortunately, this leads not only to shorter filament lifetime but also to an increase in metal evaporation from the filament, which degrades the performance of the H{sup -} conversion surface. In order to overcome these limitations we have designed and tested a prototype of a surface conversion H{sup -} ion source, based on excitation of helicon plasma wave mode with an external antenna. The source has been operated with and without cesium injection. An H{sup -} beam current of over 12 mA has been transported through the low energy beam transport of the LANSCE ion source test stand. The results of these experiments and the effects of different source parameters on the extracted beam current are presented. The limitations of the source prototype are discussed and future improvements are proposed based on the experimental observations.

  8. Washer-Gun Plasma Source for Magnetic Reconnection Experiments on VTF

    Science.gov (United States)

    Vrublevskis, A.; Egedal, J.; Fox, W.; Katz, N.; Le, A.; Porkolab, M.

    2009-11-01

    We present a recently built electrostatic washer-gun plasma source for the Versatile Toroidal Facility (VTF). The source produces plasmas with estimated densities of ˜10^19 m^- 3 and electron temperatures of ˜5-20 eV. The present plasma source for VTF is microwave-induced electron cyclotron resonant breakdown and requires a strong toroidal magnetic field, which acts as a guide field in reconnection experiments. The gun will allow reconnection experiments with no guide field. The source is based on the design developed by Sterling Scientific [1, 2]. To operate, gas is injected into a channel formed by a stack of alternating molybdenum and boron nitride washers with a molybdenum electrode washer at each end. A capacitor bank is discharged through these electrodes and the gas. The resulting plasma escapes the channel into the main chamber of the experiment. If available, we will present data on argon plasma produced by the gun inside the VTF. [1ex] [1] G. Fiksel, et al., Plasma Sources Sci. Technol., 5, 78 (1996)[0ex] [2] D. Hartog et al., Plasma Sources Sci. Technol., 6, 492 (1997)

  9. Droplet-free high-density metal ion source for plasma immersion ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Keiji [Department of Electrical Engineering, College of Engineering, Chubu University, 1200 Matsumoto, Kasugai, Aichi 487-8501 (Japan)]. E-mail: nakamura@solan.chubu.ac.jp; Yoshinaga, Hiroaki [Department of Electrical Engineering, Doshisha University, 1-3 Tatara Miyakodani, Kyotanabe, Kyoto 610-0321 (Japan); Yukimura, Ken [Department of Electrical Engineering, Doshisha University, 1-3 Tatara Miyakodani, Kyotanabe, Kyoto 610-0321 (Japan)

    2006-01-15

    This paper reports on plasma parameters and ion composition of droplet-free Zr ion source for plasma immersion ion implantation and deposition (PIII and D). Zirconium (Zr) ions were obtained by ionizing sputtered Zr atoms in inductively-coupled argon discharge. The characteristics of plasma density, plasma potential and electron temperature were typical ones of such a inductive discharge, and the plasma parameters were not significantly influenced by mixing the sputtered Zr atoms into the plasma. Actually, the main ionic component was still Ar{sup +} ions, and the ion density ratio of [Zr{sup +}]/[Ar{sup +}] was as low as {approx}8%. Increase in sputtering rate of the Zr source will be necessary to improve the ion density ratio.

  10. Optimum plasma grid bias for a negative hydrogen ion source operation with Cs

    Energy Technology Data Exchange (ETDEWEB)

    Bacal, Marthe, E-mail: marthe.bacal@lpp.polytechnique.fr [UPMC, LPP, Ecole Polytechnique, UMR CNRS 7648, Palaiseau (France); Sasao, Mamiko [R& D Promotion Organization, Doshisha University, Kamigyoku, Kyoto 602-8580 (Japan); Wada, Motoi [School of Science and Engineering, Doshisha University, Kyotonabe, Kyoto 610-0321 (Japan); McAdams, Roy [CCFE, Culham Science Center, Abingdon, Oxfordshire 0X14 3DB (United Kingdom)

    2016-02-15

    The functions of a biased plasma grid of a negative hydrogen (H{sup −}) ion source for both pure volume and Cs seeded operations are reexamined. Proper control of the plasma grid bias in pure volume sources yields: enhancement of the extracted negative ion current, reduction of the co-extracted electron current, flattening of the spatial distribution of plasma potential across the filter magnetic field, change in recycling from hydrogen atomic/molecular ions to atomic/molecular neutrals, and enhanced concentration of H{sup −} ions near the plasma grid. These functions are maintained in the sources seeded with Cs with additional direct emission of negative ions under positive ion and neutral hydrogen bombardment onto the plasma electrode.

  11. Combustion flame-plasma hybrid reactor systems, and chemical reactant sources

    Science.gov (United States)

    Kong, Peter C

    2013-11-26

    Combustion flame-plasma hybrid reactor systems, chemical reactant sources, and related methods are disclosed. In one embodiment, a combustion flame-plasma hybrid reactor system comprising a reaction chamber, a combustion torch positioned to direct a flame into the reaction chamber, and one or more reactant feed assemblies configured to electrically energize at least one electrically conductive solid reactant structure to form a plasma and feed each electrically conductive solid reactant structure into the plasma to form at least one product is disclosed. In an additional embodiment, a chemical reactant source for a combustion flame-plasma hybrid reactor comprising an elongated electrically conductive reactant structure consisting essentially of at least one chemical reactant is disclosed. In further embodiments, methods of forming a chemical reactant source and methods of chemically converting at least one reactant into at least one product are disclosed.

  12. Shaping the electron beams with submicrosecond pulse duration in sources and electron accelerators with plasma emitters

    CERN Document Server

    Gushenets, V I

    2001-01-01

    One studies the techniques in use to shape submicrosecond electron beams and the physical processes associated with extraction of electrons from plasma in plasma emitters. Plasma emitter base sources and accelerators enable to generate pulse beams with currents varying from tens of amperes up to 10 sup 3 A, with current densities up to several amperes per a square centimeter, with pulse duration constituting hundreds of nanoseconds and with high frequencies of repetition

  13. Characterization of an atmospheric pressure air plasma source for polymer surface modification

    Science.gov (United States)

    Yang, Shujun; Tang, Jiansheng

    2013-10-01

    An atmospheric pressure air plasma source was generated through dielectric barrier discharge (DBD). It was used to modify polyethyleneterephthalate (PET) surfaces with very high throughput. An equivalent circuit model was used to calculate the peak average electron density. The emission spectrum from the plasma was taken and the main peaks in the spectrum were identified. The ozone density in the down plasma region was estimated by Absorption Spectroscopy. NSF and ARC-ODU

  14. Epitaxial aluminum nitride tunnel barriers grown by nitridation with a plasma source

    NARCIS (Netherlands)

    Zijlstra, T.; Lodewijk, C.F.J.; Vercruyssen, N.; Tichelaar, F.D.; Loudkov, D.N.; Klapwijk, T.M.

    2007-01-01

    High critical current-density (10 to 420 kA/cm2) superconductor-insulator-superconductor tunnel junctions with aluminum nitride barriers have been realized using a remote nitrogen plasma from an inductively coupled plasma source operated in a pressure range of 10−3–10−1 mbar. We find a much better r

  15. Plasma diagnostics approach to welding heat source/molten pool interaction

    Energy Technology Data Exchange (ETDEWEB)

    Key, J.F.; McIlwain, M.E.; Isaacson, L.

    1980-01-01

    Plasma diagnostic techniques show that weld fusion zone profile and loss of metal vapors from the molten pool are strongly dependent on both the intensity and distribution of the heat source. These plasma properties, are functions of cathode vertex angle and thermal conductivity of the shielding gas, especially near the anode.

  16. Counter-facing plasma focus system as an efficient and long-pulse EUV light source

    Science.gov (United States)

    Kuwabara, H.; Hayashi, K.; Kuroda, Y.; Nose, H.; Hotozuka, K.; Nakajima, M.; Horioka, K.

    2011-04-01

    A plasma focus system composed of a pair of counter-facing coaxial plasma guns is proposed as a long-pulse and efficient EUV light source. A proof-of-concept experiment demonstrated that with an assist of breakdown and outer electrode connections, current sheets evolved into a configuration for stable plasma confinement at the center of the electrode. The current sheets could successively compress and confine the high energy density plasma every half period of the discharge current, enabling highly repetitive light emissions in extreme ultraviolet region with time duration in at least ten microseconds for Xe plasma. Also, we confirmed operations of our system for Li plasma. We estimated the highest EUV energy in Li plasma operation at 93mJ/4π sr per 2% bandwidth per pulse.

  17. Injection of auxiliary electrons for increasing the plasma density in highly charged and high intensity ion sources

    Science.gov (United States)

    Odorici, F.; Malferrari, L.; Montanari, A.; Rizzoli, R.; Mascali, D.; Castro, G.; Celona, L.; Gammino, S.; Neri, L.

    2016-02-01

    Different electron guns based on cold- or hot-cathode technologies have been developed since 2009 at INFN for operating within ECR plasma chambers as sources of auxiliary electrons, with the aim of boosting the source performances by means of a higher plasma lifetime and density. Their application to microwave discharge ion sources, where plasma is not confined, has required an improvement of the gun design, in order to "screen" the cathode from the plasma particles. Experimental tests carried out on a plasma reactor show a boost of the plasma density, ranging from 10% to 90% when the electron guns are used, as explained by plasma diffusion models.

  18. Injection of auxiliary electrons for increasing the plasma density in highly charged and high intensity ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Odorici, F., E-mail: fabrizio.odorici@bo.infn.it; Malferrari, L.; Montanari, A. [INFN—Bologna, Viale B. Pichat, 6/2, 40127 Bologna (Italy); Rizzoli, R. [INFN—Bologna, Viale B. Pichat, 6/2, 40127 Bologna (Italy); CNR–Istituto per la Microelettronica ed i Microsistemi, Via Gobetti 101, 40129 Bologna (Italy); Mascali, D.; Castro, G.; Celona, L.; Gammino, S.; Neri, L. [INFN–Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy)

    2016-02-15

    Different electron guns based on cold- or hot-cathode technologies have been developed since 2009 at INFN for operating within ECR plasma chambers as sources of auxiliary electrons, with the aim of boosting the source performances by means of a higher plasma lifetime and density. Their application to microwave discharge ion sources, where plasma is not confined, has required an improvement of the gun design, in order to “screen” the cathode from the plasma particles. Experimental tests carried out on a plasma reactor show a boost of the plasma density, ranging from 10% to 90% when the electron guns are used, as explained by plasma diffusion models.

  19. Characterization of the Inductively Heated Plasma Source IPG6-B

    Science.gov (United States)

    Dropmann, Michael; Laufer, Rene; Herdrich, Georg; Matthews, Lorin; Hyde, Truell

    2014-10-01

    In close collaboration between the Center for Astrophysics, Space Physics and Engineering Research (CASPER) at Baylor University, Texas, and the Institute of Space Systems (IRS) at the University of Stuttgart, Germany, two plasma facilities have been established using the Inductively heated Plasma Generator 6 (IPG6). The facility at Baylor University (IPG6-B) works at a frequency of 13.56 MHz and a maximum power of 15 kW. A vacuum pump of 160 m3/h in combination with a butterfly valve allows pressure control over a wide range. Intended fields of research include basic investigation into thermo-chemistry and plasma radiation, space plasma environments and high heat fluxes e.g. those found in fusion devices or during atmospheric re-entry of spacecraft. After moving the IPG6-B facility to the Baylor Research and Innovation Collaborative (BRIC) it was placed back into operation during the summer of 2014. Initial characterization in the new lab, using a heat flux probe, Pitot probe and cavity calorimeter, has been conducted for Air, Argon and Helium. The results of this characterization are presented.

  20. A solar powered handheld plasma source for microbial decontamination applications

    Science.gov (United States)

    Ni, Y.; Lynch, M. J.; Modic, M.; Whalley, R. D.; Walsh, J. L.

    2016-09-01

    A fully portable atmospheric pressure air plasma system is reported to be suitable for the microbial decontamination of both surfaces and liquids. The device operates in quiescent air, and includes an integrated battery which is charged from a solar cell and weighs less than 750 g, making it highly amenable for a wide variety of applications beyond the laboratory. Using particle imaging velocimetry to visualise air flows around the device, the geometric configuration of the plasma generating electrodes was enhanced to induce a gas flow on the order of 0.5 m s-1 directed towards a sample placed downstream, thus improving the transport of plasma generated reactive species to the sample. The microbial decontamination efficiency of the system was assessed using potable water samples inoculated with common waterborne organisms Escherichia coli and Pseudomonas fluorescens. The reduction in the number of microorganisms was found to be in the range of 2-8 log and was strongly dependent on the plasma generation conditions.

  1. High-density operation of the Proto-MPEX High Intensity Plasma Source

    Science.gov (United States)

    Caughman, J. B. O.; Goulding, R. H.; Biewer, T. M.; Bigelow, T. S.; Campbell, I. H.; Caneses, J.; Diem, S. J.; Martin, E. H.; Parish, C. M.; Rapp, J.; Ray, H. B.; Shaw, G. C.; Showers, M. A.; Donovan, D.; Piotrowicz, P. A.; Martin, D. C.

    2016-10-01

    The Prototype Materials Plasma Experiment (Proto-MPEX) is a linear high-intensity RF plasma source that combines a high-density helicon plasma generator with ion and electron heating sections. It is being used to study the physics of heating over-dense plasmas in a linear configuration with the goal of delivering a plasma heat flux of 10 MW/m2 at a target. The helicon plasma is produced by coupling 13.56 MHz RF power at levels of >100 kW. A 30 kW ion cyclotron antenna has recently been installed, and microwaves at 28 GHz ( 150 kW) are coupled to the electrons in the over-dense helicon plasma via Electron Bernstein Waves (EBW). High plasma densities near the target have been produced in D ( 5 x1019/m3) , and electron temperatures range from 3 to >10 eV, depending on the source parameters. IR camera images of the target plate indicate plasma heat depositions >10 MW/m2 for some operating conditions. Details of the experimental results of the operational domain with respect to Te and ne as well as results from initial plasma material interaction tests will be presented. ORNL is managed by UT-Battelle, LLC, for the U.S. DOE under contract DE-AC-05-00OR22725.

  2. Optimization of negative ion current in a compact microwave driven upper hybrid resonance multicusp plasma source.

    Science.gov (United States)

    Sahu, D; Bhattacharjee, S; Singh, M J; Bandyopadhyay, M; Chakraborty, A

    2012-02-01

    Performance of a microwave driven upper hybrid resonance multicusp plasma source as a volume negative ion source is reported. Microwaves are directly launched into the plasma chamber predominantly in the TE(11) mode. The source is operated at different discharge conditions to obtain the optimized negative H(-) ion current which is ∼33 μA (0.26 mA∕cm(2)). Particle balance equations are solved to estimate the negative ion density, which is compared with the experimental results. Future prospects of the source are discussed.

  3. Low Temperature Plasma Science: Not Only the Fourth State of Matter but All of Them. Report of the Department of Energy Office of Fusion Energy Sciences Workshop on Low Temperature Plasmas, March 25-57, 2008

    Energy Technology Data Exchange (ETDEWEB)

    None

    2008-09-01

    Low temperature plasma science (LTPS) is a field on the verge of an intellectual revolution. Partially ionized plasmas (often referred to as gas discharges) are used for an enormous range of practical applications, from light sources and lasers to surgery and making computer chips, among many others. The commercial and technical value of low temperature plasmas (LTPs) is well established. Modern society would simply be less advanced in the absence of LTPs. Much of this benefit has resulted from empirical development. As the technology becomes more complex and addresses new fields, such as energy and biotechnology, empiricism rapidly becomes inadequate to advance the state of the art. The focus of this report is that which is less well understood about LTPs - namely, that LTPS is a field rich in intellectually exciting scientific challenges and that addressing these challenges will result in even greater societal benefit by placing the development of plasma technologies on a solid science foundation. LTPs are unique environments in many ways. Their nonequilibrium and chemically active behavior deviate strongly from fully ionized plasmas, such as those found in magnetically confined fusion or high energy density plasmas. LTPs are strongly affected by the presence of neutral species-chemistry adds enormous complexity to the plasma environment. A weakly to partially ionized gas is often characterized by strong nonequilibrium in the velocity and energy distributions of its neutral and charged constituents. In nonequilibrium LTP, electrons are generally hot (many to tens of electron volts), whereas ions and neutrals are cool to warm (room temperature to a few tenths of an electron volt). Ions and neutrals in thermal LTP can approach or exceed an electron volt in temperature. At the same time, ions may be accelerated across thin sheath boundary layers to impact surfaces, with impact energies ranging up to thousands of electron volts. These moderately energetic electrons

  4. Operation of a microwave plasma source for electron heating and antenna testing

    Science.gov (United States)

    Caughman, J. B. O.; Bigelow, T. S.; Diem, S. J.; Goulding, R. H.; Rasmussen, D. A.; Schaich, C. R.; White, T. L.

    2011-10-01

    One of the major challenges for magnetic fusion is the interaction of the plasma with materials. Linear plasma-material interaction test stands can benefit from additional electron heating of the high-density source plasma to increase the total plasma heat flux at the target to better simulate fusion reactor conditions (10-20 MW/m2). A microwave-based plasma experiment has begun at ORNL to study electron heating of over-dense plasmas and to provide a plasma environment for antenna testing. The plasma is generated by high-field launched whistler waves at 18 GHz to create a moderate-density plasma (ne ~1018/m3). Electron heating of the over-dense plasma is provided by either whistler waves or electron Bernstein waves at 6 GHz. In addition, a single strap mockup antenna, designed to operate at 40-50 MHz, is being constructed to study near-field plasma interactions. The antenna will be placed in the experiment's central vacuum chamber, which will act as an rf test facility. ORNL is managed by UT-Battelle, LLC, for the U.S. DOE under contract DE-AC-05-00OR22725.

  5. High power microwave source for a plasma wakefield experiment

    Science.gov (United States)

    Shafir, G.; Shlapakovski, A.; Siman-Tov, M.; Bliokh, Yu.; Leopold, J. G.; Gleizer, S.; Gad, R.; Rostov, V. V.; Krasik, Ya. E.

    2017-01-01

    The results of the generation of a high-power microwave (˜550 MW, 0.5 ns, ˜9.6 GHz) beam and feasibility of wakefield-excitation with this beam in under-dense plasma are presented. The microwave beam is generated by a backward wave oscillator (BWO) operating in the superradiance regime. The BWO is driven by a high-current electron beam (˜250 keV, ˜1.5 kA, ˜5 ns) propagating through a slow-wave structure in a guiding magnetic field of 2.5 T. The microwave beam is focused at the desired location by a dielectric lens. Experimentally obtained parameters of the microwave beam at its waist are used for numerical simulations, the results of which demonstrate the formation of a bubble in the plasma that has almost 100% electron density modulation and longitudinal and transverse electric fields of several kV/cm.

  6. Ionized PVD with an Inductively Coupled Plasma Source

    Science.gov (United States)

    Hayden, D. B.; Juliano, D. R.; Ruzic, D. N.

    1997-10-01

    Ionized physical vapor deposition (iPVD) is used to enhance the directionality of metal deposition. This is a potential solution to depositing into higher aspect-ratio trenches and vias for metal interconnects. A dc magnetron (Donated by Materials Research Corporation) is coupled with an inductively coupled plasma (ICP) coil to increase the ionization of the sputtered metal atoms. This allows metal ions to be accelerated across the plasma sheath to a biased substrate and deposited normally. One coil design has a wider diameter than the substrate to reduce shadowing and flaking effects. Argon and neon working gases and aluminum and copper targets are investigated at varying pressures and power levels. Deposition rates and metal flux ionization fractions are measured with a quartz crystal microbalance and a multi-grid analyzer.

  7. Abatement of Perfluorinated Compounds Using Cylindrical Microwave Plasma Source at Low Pressure

    Science.gov (United States)

    Kim, Seong Bong; Park, S.; Park, Y.; Youn, S.; Yoo, S. J.

    2016-10-01

    Microwave plasma source with a cylindrical cavity has been proposed to abate the perfluorinated compounds (PFCs). This plasma source was designed to generate microwave plasma with the cylindrical shape and to be easily installed in existing exhaust line. The microwave frequency is 2.45 GHz and the operating pressure range is 0.1 Torr to 0.3 Torr. The plasma characteristic of the cylindrical microwave plasma source was measured using the optical spectrometer, and tunable diode laser absorption spectroscopy (TDLAS). The destruction and removal efficiency (DRE) of CF4 and CHF3 were measured by a quadrupole mass spectroscopy (QMS) with the various operation conditions. The effect of the addition of the oxygen gas were tested and also the correlation between the plasma parameters and the DRE are presented in this study. This work was supported by R&D Program of ``Plasma Advanced Technology for Agriculture and Food (Plasma Farming)'' through the National Fusion Research Institute of Korea (NFRI) funded by the Government funds.

  8. High electronegativity multi-dipolar electron cyclotron resonance plasma source for etching by negative ions

    DEFF Research Database (Denmark)

    Stamate, Eugen; Draghici, M.

    2012-01-01

    A large area plasma source based on 12 multi-dipolar ECR plasma cells arranged in a 3 x 4 matrix configuration was built and optimized for silicon etching by negative ions. The density ratio of negative ions to electrons has exceeded 300 in Ar/SF6 gas mixture when a magnetic filter was used...... to reduce the electron temperature to about 1.2 eV. Mass spectrometry and electrostatic probe were used for plasma diagnostics. The new source is free of density jumps and instabilities and shows a very good stability for plasma potential, and the dominant negative ion species is F-. The magnetic field...... in plasma volume is negligible and there is no contamination by filaments. The etching rate by negative ions measured in Ar/SF6/O-2 mixtures was almost similar with that by positive ions reaching 700 nm/min. (C) 2012 American Institute of Physics...

  9. Pushing the Frontiers of Science with Synchrotron Radiation: BESAC Panel on DOE Synchrotron Radiation Sources and Science

    Science.gov (United States)

    Birgeneau, Robert J.

    1998-04-01

    During 1997 a panel empowered by the Basic Energy Sciences Advisory Committee and chaired by the speaker carried out a comprehensive review of the four DOE synchrotron sources, the ALS, APS, NSLS and SSRL^1.(Report of Basic Energy Sciences Advisory Committee Panel on DOE Synchrotron Radiation Sources and Science, November 1997) We also reviewed the science and technology, past and present, carried out at these facilities. This included the areas of materials research, surface science, polymers and other forms of soft condensed matter, atomic, optical, and molecular physics and chemistry, molecular environmental science, the geosciences and structural biology. We also considered more cursorily ongoing and proposed research on fourth generation sources. The most straightforward and most important conclusion of this study is that over the past 20 years in the United States synchrotron radiation research has evolved from an esoteric endeavor practiced by a small number of scientists primarily from the fields of solid state physics and surface science to a mainstream activity which provides essential information in all of the above fields. The user community at U.S. synchrotron facilities continues to grow exponentially, having reached more than 4000 on-site users annually in FY97. The research carried out at the four DOE synchrotron sources is both very broad and often exceptionally deep. We will review the results of this study with emphasis on the current science and anticipated future research carried out at modern synchrotron sources.

  10. PARTICIPANT SUPPORT FOR THE 2010 GORDON RESEARCH CONFERENCE ON PLASMA PROCESSING SCIENCE (JULY 11-16,2010)

    Energy Technology Data Exchange (ETDEWEB)

    Uwe Kortshagen

    2011-06-14

    The 2010 Gordon Research Conference on Plasma Processing Science will feature a comprehensive program that will highlight the most cutting edge scientific advances in low temperature plasma science and will explore the applications of low temperature plasma technology relative to many grand societal challenges. Fundamental science sessions will focus on plasma kinetics, plasma surface interactions, and recent trends in plasma generation and multi-phase plasmas. Application sessions will explore the impact of plasma technology in renewable energy and the production of fuels from renewable feedstocks, plasma-enabled medicine and sterilization, and environmental remediation and waste treatment. The conference will bring together in an informal atmosphere leaders in the field with junior investigators and graduate students. The special format of the Gordon Conferences, with programmed discussion sessions and ample time for informal gatherings in the afternoons and evenings, will provide for a fertile atmosphere of brainstorming and creative thinking among the attendees.

  11. Microstructure and Properties of Plasma Source Nitrided AISI 316 Austenitic Stainless Steel

    Science.gov (United States)

    Li, G. Y.; Lei, M. K.

    2016-11-01

    Plasma source nitriding is a relatively new nitriding technology which can overcome those inherent shortcomings associated with conventional direct current plasma nitriding technology such as the arcing surface damage, the edging effect and the hollow cathode effect. There is considerable study on the properties of nitrided samples for laboratorial scale plasma source nitriding system; however, little information has been reported on the industrial-scale plasma source nitriding system. In this work, AISI 316 austenitic stainless steel samples were nitrided by an industrial-scale plasma source nitriding system at various nitriding temperatures (350, 400, 450 and 500 °C) with a floating potential. A high-nitrogen face-centered-cubic phase (γN) formed on the surface of nitrided sample surface. As the nitriding temperature was increased, the γN phase layer thickness increased, varying from 1.5 μm for the lowest nitriding temperature of 350 °C, to 30 μm for the highest nitriding temperature of 500 °C. The maximum Vickers microhardness of the γN phase layer with a peak nitrogen concentration of 20 at.% is about HV 0.1 N 15.1 GPa at the nitriding temperature of 450 °C. The wear and corrosion experimental results demonstrated that the γN phase was formed on the surface of AISI 316 austenitic stainless steel by plasma source nitriding, which exhibits not only high wear resistance, but also good pitting corrosion resistance.

  12. Plasma characteristics in inductively and capacitively coupled hybrid source using single RF power

    Science.gov (United States)

    Kim, Kwan-Yong; Lee, Moo-Young; Kim, Tae-Woo; Kim, Ju-Ho; Chung, Chin-Wook

    2016-09-01

    Parallel combined inductively coupled plasma (ICP) and capacitively coupled plasma (CCP) using single RF generator was proposed to linear control of the plasma density with RF power. In the case of ICP, linear control of the plasma density is difficult because there is a density jump up due to E to H transition. Although the plasma density of CCP changes linearly with power, the density is lower than that of ICP due to high ion energy loss at the substrate. In our hybrid source, the single RF power generator was connected to electrode and antenna, and the variable capacitor was installed between the antenna and the power generator to control the current flowing through the antenna and the electrode. By adjusting the current ratio between the antenna and the electrode, linear characteristic of plasma density with RF power is achieved.

  13. Virtual Labs (Science Gateways) as platforms for Free and Open Source Science

    Science.gov (United States)

    Lescinsky, David; Car, Nicholas; Fraser, Ryan; Friedrich, Carsten; Kemp, Carina; Squire, Geoffrey

    2016-04-01

    The Free and Open Source Software (FOSS) movement promotes community engagement in software development, as well as provides access to a range of sophisticated technologies that would be prohibitively expensive if obtained commercially. However, as geoinformatics and eResearch tools and services become more dispersed, it becomes more complicated to identify and interface between the many required components. Virtual Laboratories (VLs, also known as Science Gateways) simplify the management and coordination of these components by providing a platform linking many, if not all, of the steps in particular scientific processes. These enable scientists to focus on their science, rather than the underlying supporting technologies. We describe a modular, open source, VL infrastructure that can be reconfigured to create VLs for a wide range of disciplines. Development of this infrastructure has been led by CSIRO in collaboration with Geoscience Australia and the National Computational Infrastructure (NCI) with support from the National eResearch Collaboration Tools and Resources (NeCTAR) and the Australian National Data Service (ANDS). Initially, the infrastructure was developed to support the Virtual Geophysical Laboratory (VGL), and has subsequently been repurposed to create the Virtual Hazards Impact and Risk Laboratory (VHIRL) and the reconfigured Australian National Virtual Geophysics Laboratory (ANVGL). During each step of development, new capabilities and services have been added and/or enhanced. We plan on continuing to follow this model using a shared, community code base. The VL platform facilitates transparent and reproducible science by providing access to both the data and methodologies used during scientific investigations. This is further enhanced by the ability to set up and run investigations using computational resources accessed through the VL. Data is accessed using registries pointing to catalogues within public data repositories (notably including the

  14. Research in space science and technology. [including X-ray astronomy and interplanetary plasma physics

    Science.gov (United States)

    Beckley, L. E.

    1977-01-01

    Progress in various space flight research programs is reported. Emphasis is placed on X-ray astronomy and interplanetary plasma physics. Topics covered include: infrared astronomy, long base line interferometry, geological spectroscopy, space life science experiments, atmospheric physics, and space based materials and structures research. Analysis of galactic and extra-galactic X-ray data from the Small Astronomy Satellite (SAS-3) and HEAO-A and interplanetary plasma data for Mariner 10, Explorers 47 and 50, and Solrad is discussed.

  15. US-Japan IEC Workshop on Small Plasma and Accelerator Neutron Sources

    Energy Technology Data Exchange (ETDEWEB)

    Miley, George H. [Univ. of Illinois, Champaign, IL (United States). Dept. of Nuclear, Plasma, and Radiological Engineering

    2007-05-25

    This report lays out the agenda for the entire workshop and then lists the abstracts for all 29 presentations. All of these presentations cover small plasma and accelerator neutron sources. A few of the presentations include: Comments about IEC History and Future Directions; Characteristics in Pulse Operation of IEC Device with Confronting Two Plasma Sources; Overview of the University of Wisconsin-Madison IEC Program; Improving IEC Particle Confinement Times Using Multiple Grids; Integral Transport Approach for Molecular Ion Processes in IEC Devices; A Counter Stream Beam D-D Neutron Generator; Low Pressure IECF Operation Using Differentially-Pumped Ion Sources, and more.

  16. High-resolution VUV spectrometer/detector investigations of rare-earth pulsed plasma source (abstract)

    Science.gov (United States)

    Roberts, J. R.; Cromer, C. L.; Bridges, J. M.; Lucatorto, T. B.

    1985-05-01

    A 1.5-m grazing incidence spectrometer with a channel electron multiplier (CEMA) and electronic readout detector has been incorporated with a rare-earth target, pulsed plasma, continuum source. The spectrometer is compact and portable while maintaining high resolution. The CEMA detector consists of a single multichannel plate (MCP) with coned-shaped input pores which are cut at a 15-degree bias to improve efficiency at grazing angles. The source is a rare-earth plasma generated by a 10-J ruby laser producing intense continuum emission for wavelengths from 170 to 5 nm. This system will be used for both stationary and transient high-resolution atomic photoabsorption spectroscopy. The pulsed plasma source itself will be investigated for suitability as a radiometric transfer standard source. Preliminary results obtained with this integrated system will be discussed.

  17. Multicusp type Electron Cyclotron Resonance ion source for plasma processing

    Energy Technology Data Exchange (ETDEWEB)

    Amemiya, Hiroshi; Shigueoka, Yoshyuki (Institute of Physical and Chemical Research, Wako, Saitama (Japan)); Ishii, Shigeyuki

    1991-02-01

    A multi-cusp type ECR (electron cyclotron resonance) ion source is built with use of SmCo magnets and 2.45 GHz-TE{sub 11} circular mode microwave. The ion source is operated at pressures from 10{sup -4} to 10{sup -3} Torr with the input microwave power from 100 to 400 W. In hydrogen, the current density of H{sup +} is higher than those of H{sub 2}{sup +} and H{sub 3}{sup +}. The dependence of the fraction of each ion species on the power and pressure is measured and explained by rate equations. The source is operated also in other gases. Mass spectra in He, N{sub 2}, O{sub 2}, Ar and CH{sub 4} are shown together with the pressure and power dependences. Multicharged state of up to 3 has been obtained. (author).

  18. The Science and Technology Challenges of the Plasma-Material Interface for Magnetic Fusion Energy

    Science.gov (United States)

    Whyte, Dennis

    2013-09-01

    The boundary plasma and plasma-material interactions of magnetic fusion devices are reviewed. The boundary of magnetic confinement devices, from the high-temperature, collisionless pedestal through to the surrounding surfaces and the nearby cold high-density collisional plasmas, encompasses an enormous range of plasma and material physics, and their integrated coupling. Due to fundamental limits of material response the boundary will largely define the viability of future large MFE experiments (ITER) and reactors (e.g. ARIES designs). The fusion community faces an enormous knowledge deficit in stepping from present devices, and even ITER, towards fusion devices typical of that required for efficient energy production. This deficit will be bridged by improving our fundamental science understanding of this complex interface region. The research activities and gaps are reviewed and organized to three major axes of challenges: power density, plasma duration, and material temperature. The boundary can also be considered a multi-scale system of coupled plasma and material science regulated through the non-linear interface of the sheath. Measurement, theory and modeling across these scales are reviewed, with a particular emphasis on establishing the use dimensionless parameters to understand this complex system. Proposed technology and science innovations towards solving the PMI/boundary challenges will be examined. Supported by US DOE award DE-SC00-02060 and cooperative agreement DE-FC02-99ER54512.

  19. Innovative research of plasma physics for life sciences

    Science.gov (United States)

    Boonyawan, D.

    2017-06-01

    In medicine, cold atmospheric plasma (CAP) for the medical treatment is a new field in plasma application, called plasma medicine. CAP contains mix of excited atoms and molecules, UV photons, charged particles as well as reactive oxygen species (ROS) and reactive nitrogen species (RNS). Typical species in air-CAPs are O3, OH, NxOx, and HNOx. The current developments in this field have fuelled the hope that CAP could be an interesting new therapeutic approach in the treatment of cancer. CAP apparently demonstrated effect on cancer cell apoptosis which did not induce cell necrosis or disruption. Moreover, CAP seemed to be selective for cancer cells since it was more effective in tumor cells than in normal non-neoplastic cells. In bioscience, dentistry and veterinary medicine : Since CAP, is delivered at room temperature, which results in less damaging effects on living tissue, while still has the efficiency in disinfection and sterilization. Recent studies proved that it is able to inactivate gram-negative and gram-positive bacteria, fungi, virus, spore, various parasites, and foreign organisms or pathogens without harming tissue. Moreover, cold plasma has been used effectively in medical field such as dental use, inducing apoptosis of malignant cells, stopping bleeding, promoting wound healing and tissue regeneration. Sericin hydrolysates, originating from silkworm is found support cell proliferation, expand cell adhesion and increase cell yield. The covalent linkage between a bioactive protein molecule and polystyrene dish surface via a carbon intermediate layer can slow down the release rate of protein compound into the phosphate buffer saline (PBS) solution. We found that a-C films and a-C:N2 films show good attachment of human bone marrow-derived mesenchymal stem cells (hBM-MSCs). All of carbon modified-Polystyrene(PS) dishes revealed the less release rate of sericin molecules into PBS solution than PS control.

  20. High Power Light Gas Helicon Plasma Source for VASIMR

    Science.gov (United States)

    Squire, Jared P.; Chang-Diaz, Franklin R.; Glover, Timothy W.; Jacobson, Verlin T.; Baity, F. Wally; Carter, Mark D.; Goulding, Richard H.

    2004-01-01

    In the Advanced Space Propulsion Laboratory (ASPL) helicon experiment (VX-10) we have measured a plasma flux to input gas rate ratio near 100% for both helium and deuterium at power levels up to 10 kW. Recent results at Oak Ridge National Laboratory (ORNL) show enhanced efficiency operation with a high power density, over 5 kW in a 5 cm diameter tube. Our helicon is presently 9 cm in diameter and operates up to 10 kW of input power. The data here uses a Boswell double-saddle antenna design with a magnetic cusp just upstream of the antenna. Similar to ORNL, for deuterium at near 10 kW, we find an enhanced performance of operation at magnetic fields above the lower hybrid matching condition.

  1. High Power Light Gas Helicon Plasma Source for VASIMR

    Science.gov (United States)

    Squire, Jared P.; Chang-Diaz, Franklin R.; Glover, Timothy W.; Jacobson, Verlin T.; Baity, F. Wally; Carter, Mark D.; Goulding, Richard H.

    2004-01-01

    In the Advanced Space Propulsion Laboratory (ASPL) helicon experiment (VX-10) we have measured a plasma flux to input gas rate ratio near 100% for both helium and deuterium at power levels up to 10 kW. Recent results at Oak Ridge National Laboratory (ORNL) show enhanced efficiency operation with a high power density, over 5 kW in a 5 cm diameter tube. Our helicon is presently 9 cm in diameter and operates up to 10 kW of input power. The data here uses a Boswell double-saddle antenna design with a magnetic cusp just upstream of the antenna. Similar to ORNL, for deuterium at near 10 kW, we find an enhanced performance of operation at magnetic fields above the lower hybrid matching condition.

  2. Environmental friendly high efficient light source plasma lamp - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Courret, G.; Calame, L. [Haute Ecole d' ingenierie et de gestion du canton de Vaud, Institut de micro et nano techniques, Yverdon-les-Bains (Switzerland); Meyer, A. [Solaronix SA, Aubonne (Switzerland)

    2007-07-01

    This illustrated final report for the Swiss Federal Office of Energy (SFOE) takes a look at work done on the development of a sulphur-based plasma lamp. In 2007, the capability of a new modulator has been explored. The most important results are discussed. With the production of a 1.2 cm{sup 3} bulb, the way towards the production of a 100 W lamp has been opened. The authors comment that modulation by impulses increases the luminous efficiency in comparison to modulation using a continuous sinusoidal wave. The report deals with the history of the project, the development of the new modulator, the use of rotational effects and the optimisation of the amount of active substances - tellurium and selenium - in the bulb. The electromagnetic coupling system used is described and discussed.

  3. The 5-Year Outlook on Science and Technology 1981. Source Materials Volume 2.

    Science.gov (United States)

    National Science Foundation, Washington, DC.

    This is the second of two volumes of source documents commissioned by the National Science Foundation in preparing the second 5-Year Outlook on Science and Technology for transmission to the Congress. This volume consists of the views of individuals selected by the Committee on Science, Engineering and Public Policy of the American Association for…

  4. SCIENCE AND ENGINEERING REFERENCE SOURCES, A GUIDE FOR STUDENTS AND LIBRARIANS.

    Science.gov (United States)

    MALINOWSKY, HAROLD ROBERT

    THIS TEXTBOOK IS INTENDED AS A GENERAL GUIDE TO THE SOURCES OF INFORMATION IN THE SCIENCE-ENGINEERING FIELD. REFERENCES TO STANDARD SOURCES ARE LISTED FOR THE FIELDS OF (1) GENERAL SCIENCE, (2) MATHEMATICS, (3) PHYSICS, (4) CHEMISTRY, (5) ASTRONOMY, (6) GEOLOGY, (7) BIOLOGY, (8) ENGINEERING, AND (9) MEDICINE (LIMITED). WORKS IN ENGLISH ARE…

  5. Low temperature plasmas created by photoionization of gases with intense radiation pulses from laser-produced plasma sources

    Science.gov (United States)

    Bartnik, A.; Pisarczyk, T.; Wachulak, P.; Chodukowski, T.; Fok, T.; Wegrzyński, Ł.; Kalinowska, Z.; Fiedorowicz, H.

    2016-12-01

    A comparative study of photoionized plasmas created by soft X-ray (SXR) and extreme ultraviolet (EUV) laser plasma sources was performed. The sources, employing high or low energy laser systems, utilized double-stream Xe/He gas-puff targets irradiated with laser pulses of different parameters. The SXR/EUV beams were used for irradiation of a gas stream, injected into a vacuum chamber synchronously with the radiation pulse. Photoionized plasmas produced this way in Ne gas emitted radiation in the SXR/EUV range. The corresponding spectra were dominated by emission lines originating from singly charged ions. Significant differences between spectra obtained in different experimental conditions concern specific transitions in Ne II ions. Creation of photoionized plasmas by SXR or EUV irradiation resulted in K-shell or L-shell emissions respectively. In case of the low energy system absorption spectra were measured additionally. In case of the high energy system, the electron density measurements were performed by laser interferometry, employing a femtosecond laser system. A maximum electron density reached the value of 2·1018cm-3. For the low energy system, a detection limit was too high for the interferometric measurements, thus only an upper estimation for electron density could be made.

  6. Accessibility condition of wave propagation and multicharged ion production in electron cyclotron resonance ion source plasma

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Yushi, E-mail: kato@eei.eng.osaka-u.ac.jp; Yano, Keisuke; Nishiokada, Takuya; Nagaya, Tomoki; Kimura, Daiju; Kumakura, Sho; Imai, Youta; Hagino, Shogo; Otsuka, Takuro; Sato, Fuminobu [Division of Electrical, Electronic and Information Engineering, Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita-shi, Osaka 565-0871 (Japan)

    2016-02-15

    A new tandem type source of electron cyclotron resonance (ECR) plasmas has been constructing for producing synthesized ion beams in Osaka University. Magnetic mirror field configuration with octupole magnets can be controlled to various shape of ECR zones, namely, in the 2nd stage plasma to be available by a pair mirror and a supplemental coil. Noteworthy correlations between these magnetic configurations and production of multicharged ions are investigated in detail, as well as their optimum conditions. We have been considering accessibility condition of electromagnetic and electrostatic waves propagating in ECR ion source plasma, and then investigated their correspondence relationships with production of multicharged ions. It has been clarified that there exits efficient configuration of ECR zones for producing multicharged ion beams experimentally, and then has been suggested from detail accessibility conditions on the ECR plasma that new resonance, i.e., upper hybrid resonance, must have occurred.

  7. Modelling of plasma behaviour in the vicinity of intensive impurity sources

    Science.gov (United States)

    Tokar, Mikhail Z.; Ding, Rui; Koltunov, Mikhail

    2010-07-01

    Plasma behaviour in the vicinity of strong sources of impurities is considered by taking into account quasi-neutrality, Coulomb collisions of background particles with impurity ions, radiation losses and sinks of charged particles to bounding material surfaces. If several ion species are present in the plasma the generalized Bohm criterion requires that a certain function of the main ion velocity changes its sign when moving along the magnetic field from the distant plasma through the impurity source to the surface. This allows us to formulate the 'regularity' conditions for the motion equation of the main ions and a numerical approach to find the only physical solution without singularities is elaborated. Calculations of plasma parameters in the shadow of a limiter, through which impurities are injected, have been done for the conditions of impurity seeding experiments in the tokamak TEXTOR.

  8. Evolution of plasma parameters in a He - N2/Ar magnetic pole enhanced inductive plasma source

    Science.gov (United States)

    Younus, Maria; Rehman, N. U.; Shafiq, M.; Zakaullah, M.; Abrar, M.

    2016-02-01

    A magnetic pole enhanced inductively coupled H e - N2/A r plasma is studied at low pressure, to monitor the effects of helium mixing on plasma parameters like electron number density (ne) , electron temperature (Te) , plasma potential (Vp ) , and electron energy probability functions (EEPFs). An RF compensated Langmuir probe is employed to measure these plasma parameters. It is noted that electron number density increases with increasing RF power and helium concentration in the mixture, while it decreases with increase in filling gas pressure. On the other hand, electron temperature shows an increasing trend with helium concentration in the mixture. At low RF powers and low helium concentration in the mixture, EEPFs show a "bi-Maxwellian" distribution with pressure. While at RF powers greater than 50 W and higher helium concentration in the mixture, EEPFs evolve into "Maxwellian" distribution. The variation of skin depth with RF power and helium concentration in the mixture, and its relation with EEPF are also studied. The effect of helium concentrations on the temperatures of two electron groups ( Tb u l k and Tt a i l ) in the "bi-Maxwellian" EEPFs is also observed. The temperature of low energy electron group ( Tb u l k) shows significant increase with helium addition, while the temperature of tail electrons ( Tt a i l) increases smoothly as compared to ( Tb u l k).

  9. Investigating the Relationship between Students' Science Knowledge and Their Reported Sources of Information

    Science.gov (United States)

    Buxner, S.; Romine, J.; Impey, C.; Nieberding, M.

    2015-11-01

    Building on a 25 year study of undergraduate students' science literacy, we have been investigating where students report getting information about science. In this study, we investigated the relationship between students' basic science knowledge, responses about studying something scientifically, and where they report gaining information about science. Data for this study was collected through an online survey of astronomy courses during 2014. Responses were collected from a total of 400 students through online surveys. Most survey respondents were non-science majors in the first two years of college who had taken 3 or fewer college science courses. Our results show a relationship between students who report online searches and Wikipedia as reliable sources of information and lower science literacy scores, although there was no relationship between science knowledge and where students report getting information about science. Our results suggest that information literacy is an important component to overall science literacy.

  10. Study of electron current extraction from a radio frequency plasma cathode designed as a neutralizer for ion source applications

    Energy Technology Data Exchange (ETDEWEB)

    Jahanbakhsh, Sina, E-mail: sinajahanbakhsh@gmail.com; Satir, Mert; Celik, Murat [Department of Mechanical Engineering, Bogazici University, Istanbul 34342 (Turkey)

    2016-02-15

    Plasma cathodes are insert free devices that are developed to be employed as electron sources in electric propulsion and ion source applications as practical alternatives to more commonly used hollow cathodes. Inductively coupled plasma cathodes, or Radio Frequency (RF) plasma cathodes, are introduced in recent years. Because of its compact geometry, and simple and efficient plasma generation, RF plasma source is considered to be suitable for plasma cathode applications. In this study, numerous RF plasma cathodes have been designed and manufactured. Experimental measurements have been conducted to study the effects of geometric and operational parameters. Experimental results of this study show that the plasma generation and electron extraction characteristics of the RF plasma cathode device strongly depend on the geometric parameters such as chamber diameter, chamber length, orifice diameter, orifice length, as well as the operational parameters such as RF power and gas mass flow rate.

  11. Neutral Beam Source and Target Plasma for Development of a Local Electric Field Fluctuation Diagnostic

    Science.gov (United States)

    Bakken, M. R.; Burke, M. G.; Fonck, R. J.; Lewicki, B. T.; Rhodes, A. T.; Winz, G. R.

    2016-10-01

    A new diagnostic measuring local E-> (r , t) fluctuations is being developed for plasma turbulence studies in tokamaks. This is accomplished by measuring fluctuations in the separation of the π components in the Hα motional Stark spectrum. Fluctuations in this separation are expected to be Ẽ / ẼEMSE 10-3EMSE 10-3 . In addition to a high throughput, high speed spectrometer, the project requires a low divergence (Ω 0 .5°) , 80 keV, 2.5 A H0 beam and a target plasma test stand. The beam employs a washer-stack arc ion source to achieve a high species fraction at full energy. Laboratory tests of the ion source demonstrate repeatable plasmas with Te 10 eV and ne 1.6 ×1017 m-3, sufficient for the beam ion optics requirements. Te and ne scalings of the ion source plasma are presented with respect to operational parameters. A novel three-phase resonant converter power supply will provide 6 mA/cm2 of 80 keV H0 at the focal plane for pulse lengths up to 15 ms, with low ripple δV / 80 keV 0.05 % at 280 kHz. Diagnostic development and validation tests will be performed on a magnetized plasma test stand with 0.5 T field. The test chamber will utilize a washer-stack arc source to produce a target plasma comparable to edge tokamak plasmas. A bias-plate with programmable power supply will be used to impose Ẽ within the target plasma. Work supported by US DOE Grant DE-FG02-89ER53296.

  12. Application of a pulsed, RF-driven, multicusp source for low energy plasma immersion ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Wengrow, A.B.; Leung, K.N.; Perkins, L.T.; Pickard, D.S.; Rickard, M.; Williams, M.D. [Lawrence Berkeley Lab., CA (United States); Tucker, M. [Spectrum Sciences, Inc., Santa Clara, CA (United States)

    1996-06-01

    The multicusp ion source can produce large volumes of uniform, quiescent, high density plasmas. A plasma chamber suited for plasma immersion ion implantation (PIII) was readily made. Conventional PIII pulses the bias voltage applied to the substrate which is immersed in a CW mode plasma. Here, a method by which the plasma itself is pulsed was developed. Typically pulse lengths of 500 {mu}s are used and are much shorter than that of the substrate voltage pulse (5-15 ms). This approach, together with low gas pressures and low bias voltages, permits the constant energy implantation of an entire wafer simultaneously without glow discharge. Results show that this process can yield implant currents of up to 2.5 mA/cm{sup 2}; thus very short implant times can be achieved. Uniformity of the ion flux is also discussed. As this method can be scaled to any dimension, it can be made to handle any size wafer.

  13. Behavior of moving plasma in solenoidal magnetic field in a laser ion source

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, S., E-mail: ikeda.s.ae@m.titech.ac.jp [Interdisciplinary Graduate School of Science and Engineering, Tokyo Institute of Technology, Yokohama, Kanagawa 226-8502 (Japan); Nishina Center for Accelerator-Based Science, RIKEN, Wako, Saitama 351-0108 (Japan); Takahashi, K. [Department of Electrical Engineering, Nagaoka University of Technology, Nagaoka, Niigata 940-2137 (Japan); Okamura, M. [Collider-Accelerator Department, Brookhaven National Laboratory, Upton, New York 11973-5000 (United States); Horioka, K. [Interdisciplinary Graduate School of Science and Engineering, Tokyo Institute of Technology, Yokohama, Kanagawa 226-8502 (Japan)

    2016-02-15

    In a laser ion source, a solenoidal magnetic field is useful to guide the plasma and to control the extracted beam current. However, the behavior of the plasma drifting in the magnetic field has not been well understood. Therefore, to investigate the behavior, we measured the plasma ion current and the total charge within a single pulse in the solenoid by changing the distance from the entrance of the solenoid to a detector. We observed that the decrease of the total charge along the distance became smaller as the magnetic field became larger and then the charge became almost constant with a certain magnetic flux density. The results indicate that the transverse spreading speed of the plasma decreased with increasing the field and the plasma was confined transversely with the magnetic flux density. We found that the reason of the confinement was not magnetization of ions but an influence induced by electrons.

  14. Behavior of moving plasma in solenoidal magnetic field in a laser ion source

    Science.gov (United States)

    Ikeda, S.; Takahashi, K.; Okamura, M.; Horioka, K.

    2016-02-01

    In a laser ion source, a solenoidal magnetic field is useful to guide the plasma and to control the extracted beam current. However, the behavior of the plasma drifting in the magnetic field has not been well understood. Therefore, to investigate the behavior, we measured the plasma ion current and the total charge within a single pulse in the solenoid by changing the distance from the entrance of the solenoid to a detector. We observed that the decrease of the total charge along the distance became smaller as the magnetic field became larger and then the charge became almost constant with a certain magnetic flux density. The results indicate that the transverse spreading speed of the plasma decreased with increasing the field and the plasma was confined transversely with the magnetic flux density. We found that the reason of the confinement was not magnetization of ions but an influence induced by electrons.

  15. Reference Sources in Science, Engineering, Medicine, and Agriculture.

    Science.gov (United States)

    Malinowsky, H. Robert

    This document is a bibliographic guide of over 2,400 titles in science, engineering, medicine and agriculture. This book is intended for use by librarians for reference updates, researchers and students who need to access information but who are unfamiliar with the particular discipline, and for information science students learning about the…

  16. Droplet-based, high-brightness extreme ultraviolet laser plasma source for metrology

    Science.gov (United States)

    Vinokhodov, A. Yu.; Krivokorytov, M. S.; Sidelnikov, Yu. V.; Krivtsun, V. M.; Medvedev, V. V.; Koshelev, K. N.

    2016-10-01

    We report on the development of a high brightness source of extreme ultraviolet radiation (EUV) with a working wavelength of 13.5 nm. The source is based on a laser-produced plasma driven by pulsed radiation of a Nd:YAG laser system. Liquid droplets of Sn-In eutectic alloy were used as the source fuel. The droplets were created by a droplet generator operating in the jet break-up regime. The EUV emission properties of the plasma, including the emission spectrum, time profile, and conversion efficiency of laser radiation into useful 13.5 nm photons, have been characterized. Using the shadowgraphy technique, we demonstrated the production of corpuscular debris by the plasma source and the influence of the plasma on the neighboring droplet targets. The high-frequency laser operation was simulated by usage of the dual pulse regime. Based on the experimental results, we discuss the physical phenomena that could affect the source operation at high repetition rates. Finally, we estimate that an average source brightness of 1.2 kW/mm2 sr is feasible at a high repetition rate.

  17. Hard X-ray sources from miniature plasma focus devices

    Energy Technology Data Exchange (ETDEWEB)

    Raspa, V. [Buenos Aires Univ., PLADEMA, CONICET and INFIP (Argentina); Silva, P.; Moreno, J.; Zambra, M.; Soto, L. [Comision Chilena de Energia Nuclear, Santiago (Chile)

    2004-07-01

    As first stage of a program to design a repetitive pulsed radiation generator for industrial applications, two miniature plasma foci have been designed and constructed at the Chilean commission of nuclear energy. The devices operate at an energy level of the order of tens of joules (PF-50 J, 160 nF capacitor bank, 20-35 kV, 32-100 J, {approx} 150 ns time to peak current) and hundred of joules (PF-400 J, 880 nF, 20-35 kV, 176-539 J, {approx} 300 ns time to peak current). Hard X-rays are being studied in these devices operating with hydrogen. Images of metallic plates with different thickness were obtained on commercial radiographic film, Agfa Curix ST-G2, in order to characterize the energy of the hard X-ray outside of the discharge chamber of PF-400 J. An effective energy of the order of 90 keV was measured under those conditions. X ray images of different metallic objects also have been obtained. (authors)

  18. Deposition of dielectric films on silicon using a fore-vacuum plasma electron source.

    Science.gov (United States)

    Zolotukhin, D B; Oks, E M; Tyunkov, A V; Yushkov, Yu G

    2016-06-01

    We describe an experiment on the use of a fore-vacuum-pressure, plasma-cathode, electron beam source with current up to 100 mA and beam energy up to 15 keV for deposition of Mg and Al oxide films on Si substrates in an oxygen atmosphere at a pressure of 10 Pa. The metals (Al and Mg) were evaporated and ionized using the electron beam with the formation of a gas-metal beam-plasma. The plasma was deposited on the surface of Si substrates. The elemental composition of the deposited films was analyzed.

  19. Deposition of dielectric films on silicon using a fore-vacuum plasma electron source

    Energy Technology Data Exchange (ETDEWEB)

    Zolotukhin, D. B.; Tyunkov, A. V.; Yushkov, Yu. G., E-mail: yuyushkov@gmail.com [Tomsk State University of Control Systems and Radioelectronics, 40 Lenin Ave., Tomsk 634050 (Russian Federation); Oks, E. M. [Tomsk State University of Control Systems and Radioelectronics, 40 Lenin Ave., Tomsk 634050 (Russian Federation); Institute of High Current Electronics SB RAS, 2/3, Akademichesky Ave., Tomsk 634055 (Russian Federation)

    2016-06-15

    We describe an experiment on the use of a fore-vacuum-pressure, plasma-cathode, electron beam source with current up to 100 mA and beam energy up to 15 keV for deposition of Mg and Al oxide films on Si substrates in an oxygen atmosphere at a pressure of 10 Pa. The metals (Al and Mg) were evaporated and ionized using the electron beam with the formation of a gas-metal beam-plasma. The plasma was deposited on the surface of Si substrates. The elemental composition of the deposited films was analyzed.

  20. Fullerene-rare gas mixed plasmas in an electron cyclotron resonance ion source

    CERN Document Server

    Asaji, T; Uchida, T; Minezaki, H; Ishihara, S; Racz, R; Muramatsu, M; Biri, S; Kitagawa, A; Kato, Y; Yoshida, Y

    2015-01-01

    A synthesis technology of endohedral fullerenes such as Fe@C60 has developed with an electron cyclotron resonance (ECR) ion source. The production of N@C60 was reported. However, the yield was quite low, since most fullerene molecules were broken in the ECR plasma. We have adopted gas-mixing techniques in order to cool the plasma and then reduce fullerene dissociation. Mass spectra of ion beams extracted from fullerene-He, Ar or Xe mixed plasmas were observed with a Faraday cup. From the results, the He gas mixing technique is effective against fullerene destruction.

  1. Tungsten transport and sources control in JET ITER-like wall H-mode plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Fedorczak, N., E-mail: nicolas.fedorczak@cea.fr [CEA, IRFM, F-13108 Saint-Paul-Lez-Durance (France); Monier-Garbet, P. [CEA, IRFM, F-13108 Saint-Paul-Lez-Durance (France); Pütterich, T. [MPI für Plasmaphysik, EURATOM Association, Boltzmannstrasse 2, 85748 Garching (Germany); Brezinsek, S. [Institute of Energy and Climate Research, Forschungszentrum Jlich, Assoc EURATOM-FZJ, Jlich (Germany); Devynck, P.; Dumont, R.; Goniche, M.; Joffrin, E. [CEA, IRFM, F-13108 Saint-Paul-Lez-Durance (France); Lerche, E. [Association EURATOM-Belgian State, LPP-ERM-KMS, TEC partner, Brussels (Belgium); Euratom/CCFE Fusion Association, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Lipschultz, B. [York Plasma Institute, University of York, Heslington, York YO10 5DD (United Kingdom); Luna, E. de la [Laboratorio Nacional de Fusin, Asociacin EURATOM/CIEMAT, 28040 Madrid (Spain); Maddison, G. [Culham Centre for Fusion Energy, EURATOM-CCFE Association, Abingdon (United Kingdom); Maggi, C. [MPI für Plasmaphysik, EURATOM Association, Boltzmannstrasse 2, 85748 Garching (Germany); Matthews, G. [Culham Centre for Fusion Energy, EURATOM-CCFE Association, Abingdon (United Kingdom); Nunes, I. [Istituto de plasmas e fusao nuclear, Lisboa (Portugal); Rimini, F. [Culham Centre for Fusion Energy, EURATOM-CCFE Association, Abingdon (United Kingdom); Solano, E.R. [Laboratorio Nacional de Fusin, Asociacin EURATOM/CIEMAT, 28040 Madrid (Spain); Tamain, P. [CEA, IRFM, F-13108 Saint-Paul-Lez-Durance (France); Tsalas, M. [Association EURATOM-Hellenic Republic, NCSR Demokritos 153 10, Attica (Greece); Vries, P. de [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France)

    2015-08-15

    A set of discharges performed with the JET ITER-like wall is investigated with respect to control capabilities on tungsten sources and transport. In attached divertor regimes, increasing fueling by gas puff results in higher divertor recycling ion flux, lower divertor tungsten source, higher ELM frequency and lower core plasma radiation, dominated by tungsten ions. Both pedestal flushing by ELMs and divertor screening (including redeposition) are possibly responsible. For specific scenarios, kicks in plasma vertical position can be employed to increase the ELM frequency, which results in slightly lower core radiation. The application of ion cyclotron radio frequency heating at the very center of the plasma is efficient to increase the core electron temperature gradient and flatten electron density profile, resulting in a significantly lower central tungsten peaking. Beryllium evaporation in the main chamber did not reduce the local divertor tungsten source whereas core radiation was reduced by approximately 50%.

  2. Sources of science self-efficacy beliefs of middle school students

    Science.gov (United States)

    Britner, Shari L.; Pajares, Frank

    2006-05-01

    The purpose of this study was to investigate the degree to which A. Bandura's ([1997]) hypothesized sources of self-efficacy predict the science self-efficacy beliefs of middle school students (N = 319), to replicate previous findings that science self-efficacy predicts science achievement, and to explore how science self-efficacy and its antecedents differ by gender. Significant correlations were found between mastery experiences, vicarious experiences, social persuasions, physiological arousal, and self-efficacy. Only mastery experiences significantly predicted science self-efficacy. Girls reported stronger science self-efficacy than did boys. Findings support and extend the theoretical tenets of Bandura's social cognitive theory.

  3. Plasma physics

    CERN Document Server

    Drummond, James E

    2013-01-01

    A historic snapshot of the field of plasma physics, this fifty-year-old volume offers an edited collection of papers by pioneering experts in the field. In addition to assisting students in their understanding of the foundations of classical plasma physics, it provides a source of historic context for modern physicists. Highly successful upon its initial publication, this book was the standard text on plasma physics throughout the 1960s and 70s.Hailed by Science magazine as a ""well executed venture,"" the three-part treatment ranges from basic plasma theory to magnetohydrodynamics and microwa

  4. The effect of biasing the plasma electrode on hydrogen ion formations in a multicusp ion source

    Energy Technology Data Exchange (ETDEWEB)

    Ego, Hiroyasu; Iwashita, Yoshihisa (Kyoto Univ., Uji (Japan). Inst. for Chemical Research); Takekoshi, Hidekuni

    1992-03-01

    The plasma electrode covered with magnetic cusp fields acting as a magnetic filter was installed in a multicusp ion source. The formation processes of the negative and positive hydrogen ions in this source have been investigated when an electrostatic positive bias is applied to the plasma electrode with respect to the anode chamber. The dominant H[sup -] volume-production process is the recombinational attachment rather than the dissociative attachment when the bias voltage is more than +3V. This recombinational attachment improves the H[sup +] ratio in the extracted positive beam, keeping its current value. (author) 52 refs.

  5. Non-thermal atmospheric pressure HF plasma source: generation of nitric oxide and ozone for bio-medical applications

    Science.gov (United States)

    Kühn, S.; Bibinov, N.; Gesche, R.; Awakowicz, P.

    2010-01-01

    A new miniature high-frequency (HF) plasma source intended for bio-medical applications is studied using nitrogen/oxygen mixture at atmospheric pressure. This plasma source can be used as an element of a plasma source array for applications in dermatology and surgery. Nitric oxide and ozone which are produced in this plasma source are well-known agents for proliferation of the cells, inhalation therapy for newborn infants, disinfection of wounds and blood ozonation. Using optical emission spectroscopy, microphotography and numerical simulation, the gas temperature in the active plasma region and plasma parameters (electron density and electron distribution function) are determined for varied nitrogen/oxygen flows. The influence of the gas flows on the plasma conditions is studied. Ozone and nitric oxide concentrations in the effluent of the plasma source are measured using absorption spectroscopy and electro-chemical NO-detector at variable gas flows. Correlations between plasma parameters and concentrations of the particles in the effluent of the plasma source are discussed. By varying the gas flows, the HF plasma source can be optimized for nitric oxide or ozone production. Maximum concentrations of 2750 ppm and 400 ppm of NO and O3, correspondingly, are generated.

  6. Development of plasma sources for ICRF heating experiment in KMAX mirror device

    Science.gov (United States)

    Sun, Xuan; Liu, Ming; Yi, Hongshen; Lin, Munan; Shi, Peiyun

    2016-10-01

    KMAX, Keda Mirror with AXisymmeticity, is a tandem mirror machine with a length of 10 meters and diameters of 1.2 meters in the central cell and 0.3 meters in the mirror throat. In the past experiments, the plasma was generated by helicon wave launched from the west end. We obtained the blue core mode in argon discharge, however, it cannot provide sufficient plasma for hydrogen discharge, which is at least 1012 cm-3 required for effective ICRF heating. Several attempts have thus been tried or under design to increase the central cell's plasma density: (1) a washer gun with aperture of 1cm has been successfully tested, and a plasma density of 1013 cm-3 was achieved in the west cell near the gun, however, the plasma is only 1011 cm-3 in the central cell possible due to the mirror trapping and/or neutral quenching effect (2) a larger washer gun with aperture of 2.5 cm and a higher power capacitor bank are being assembled in order to generate more plasmas. In addition, how to mitigate the neutrals is under consideration (3) A hot cathode is been designed and will be tested in combination with plasma gun or alone. Preliminary results from those plasma sources will be presented and discussed.

  7. Characteristics of cold atmospheric plasma source based on low-current pulsed discharge with coaxial electrodes

    Science.gov (United States)

    Bureyev, O. A.; Surkov, Yu S.; Spirina, A. V.

    2017-05-01

    This work investigates the characteristics of the gas discharge system used to create an atmospheric pressure plasma flow. The plasma jet design with a cylindrical graphite cathode and an anode rod located on the axis of the system allows to realize regularly reproducible spark breakdowns mode with a frequency ∼ 5 kHz and a duration ∼ 40 μs. The device generates a cold atmospheric plasma flame with 1 cm in diameter in the flow of various plasma forming gases including nitrogen and air at about 100 mA average discharge current. In the described construction the cathode spots of individual spark channels randomly move along the inner surface of the graphite electrode creating the secondary plasma stream time-average distributed throughout the whole exit aperture area after the decay of numerous filamentary discharge channels. The results of the spectral diagnostics of plasma in the discharge gap and in the stream coming out of the source are presented. Despite the low temperature of atoms and molecules in plasma stream the cathode spots operation with temperature of ∼ 4000 °C at a graphite electrode inside a discharge system enables to saturate the plasma by CN-radicals and atomic carbon in the case of using nitrogen as the working gas.

  8. An Overview of Science Education and Outreach Activities at the Princeton Plasma Physics Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    J. DeLooper; A. DeMeo; P. Lucas; A. Post-Zwicker; C. Phillips; C. Ritter; J. Morgan; P. Wieser; A. Percival; E. Starkman; G. Czechowicz

    2000-11-07

    The U. S. Department of Energy's Princeton Plasma Physics Laboratory (PPPL) has an energetic science education program and outreach effort. This overview describes the components of the programs and evaluates the changes that have occurred in this effort during the last several years. Efforts have been expanded to reach more students, as well as the public in general. The primary goal is to inform the public regarding the fusion and plasma research at PPPL and to excite students so that they can appreciate science and technology. A student's interest in science can be raised by tours, summer research experiences, in-classroom presentations, plasma expos, teacher workshops and web-based materials. The ultimate result of this effort is a better-informed public, as well as an increase in the number of women and minorities who choose science as a vocation. Measuring the results is difficult, but current metrics are reviewed. The science education and outreach programs are supported by a de dicated core group of individuals and supplemented by other members of the PPPL staff and consultants who perform various outreach and educational activities.

  9. Studies of extreme ultraviolet emission from laser produced plasmas, as sources for next generation lithography

    Science.gov (United States)

    Cummins, Thomas

    The work presented in this thesis is primarily concerned with the optimisation of extreme ultraviolet (EUV) photoemission around 13.5 nm, from laser produced tin (Sn) plasmas. EUV lithography has been identified as the leading next generation technology to take over from the current optical lithography systems, due to its potential of printing smaller feature sizes on integrated circuits. Many of the problems hindering the implementation of EUV lithography for high volume manufacturing have been overcome during the past 20 years of development. However, the lack of source power is a major concern for realising EUV lithography and remains a major roadblock that must be overcome. Therefore in order to optimise and improve the EUV emission from Sn laser plasma sources, many parameters contributing to the make-up of an EUV source are investigated. Chapter 3 presents the results of varying several different experimental parameters on the EUV emission from Sn laser plasmas. Several of the laser parameters including the energy, gas mixture, focusing lens position and angle of incidence are changed, while their effect on the EUV emission is studied. Double laser pulse experiments are also carried out by creating plasma targets for the main laser pulse to interact with. The resulting emission is compared to that of a single laser pulse on solid Sn. Chapter 4 investigates tailoring the CO2 laser pulse duration to improve the efficiency of an EUV source set-up. In doing so a new technique for shortening the time duration of the pulse is described. The direct effects of shortening the CO2 laser pulse duration on the EUV emission from Sn are then studied and shown to improve the efficiency of the source. In Chapter 5 a new plasma target type is studied and compared to the previous dual laser experiments. Laser produced colliding plasma jet targets form a new plasma layer, with densities that can be optimised for re-heating with the main CO2 laser pulse. Chapter 6 will present

  10. Atomic processes and equation of state of high Z plasmas for EUV sources and their effects on the spatial and temporal evolution of the plasmas

    Science.gov (United States)

    Sasaki, Akira; Sunahara, Atushi; Furukawa, Hiroyuki; Nishihara, Katsunobu; Nishikawa, Takeshi; Koike, Fumihiro

    2016-03-01

    Laser-produced plasma (LPP) extreme ultraviolet (EUV) light sources have been intensively investigated due to potential application to next-generation semiconductor technology. Current studies focus on the atomic processes and hydrodynamics of plasmas to develop shorter wavelength sources at λ = 6.x nm as well as to improve the conversion efficiency (CE) of λ = 13.5 nm sources. This paper examines the atomic processes of mid-z elements, which are potential candidates for λ = 6.x nm source using n=3-3 transitions. Furthermore, a method to calculate the hydrodynamics of the plasmas in terms of the initial interaction between a relatively weak prepulse laser is presented.

  11. Enhancement of H{sup -}/D{sup -} volume production in a double plasma type negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Fukumasa, Osamu; Nishimura, Hideki; Sakiyama, Satoshi [Yamaguchi Univ., Ube (Japan). Faculty of Engineering

    1997-02-01

    H{sup -}/D{sup -} production in a pure volume source has been studied. In our double plasma type negative ion source, both energy and density of fast electrons are well controlled. With the use of this source, the enhancement of H{sup -}/D{sup -} production has been observed. Namely, under the same discharge power, the extracted H{sup -}/D{sup -} current in the double plasma operation is higher than that in the single plasma operation. At the same time, measurements of plasma parameters have been made in the source and the extractor regions for these two cases. (author)

  12. Collaborative Research. Fundamental Science of Low Temperature Plasma-Biological Material Interactions

    Energy Technology Data Exchange (ETDEWEB)

    Graves, David Barry [Univ. California, Berkeley, CA (United States); Oehrlein, Gottlieb [Univ. of Maryland, College Park, MD (United States)

    2014-09-01

    Low temperature plasma (LTP) treatment of biological tissue is a promising path toward sterilization of bacteria due to its versatility and ability to operate under well-controlled and relatively mild conditions. The present collaborative research of an interdisciplinary team of investigators at University of Maryland, College Park (UMD), and University of California, Berkeley (UCB) focused on establishing our knowledge based with regard to low temperature plasma-induced chemical modifications in biomolecules that result in inactivation due to various plasma species, including ions, reactive radicals, and UV/VUV photons. The overall goals of the project were to identify and quantify the mechanisms by which low and atmospheric pressure plasma deactivates endotoxic biomolecules. Additionally, we wanted to understand the mechanism by which atmospheric pressure plasmas (APP) modify surfaces and how these modifications depend on the interaction of APP with the environment. Various low pressure plasma sources, a vacuum beam system and several atmospheric pressure plasma sources were used to accomplish this. In our work we elucidated for the first time the role of ions, VUV photons and radicals in biological deactivation of representative biomolecules, both in a UHV beam system and an inductively coupled, low pressure plasma system, and established the associated atomistic biomolecule changes. While we showed that both ions and VUV photons can be very efficient in deactivation of biomolecules, significant etching and/or deep modification (~200 nm) accompanied these biological effects. One of the most important findings in this work is the significant radical-induced deactivation and surface modification can occur with minimal etching. However, if radical fluxes and corresponding etch rates are relatively high, for example at atmospheric pressure, endotoxic biomolecule film inactivation may require near-complete removal of the film. These findings motivated further work at

  13. Narrow bandwidth Thomson photon source development using Laser-Plasma Accelerators

    Science.gov (United States)

    Geddes, C. G. R.; van Tilborg, J.; Tsai, H.-E.; Toth, Cs.; Vay, J.-L.; Lehe, R.; Schroeder, C. B.; Esarey, E.; Rykovanov, S. G.; Grote, D. P.; Friedman, A.; Leemans, W. P.

    2016-10-01

    Compact, high-quality photon sources at MeV energies are being developed based on Laser-Plasma Accelerators (LPAs). An independent scattering laser with controlled pulse shaping in frequency and amplitude can be used together with laser guiding to realize high photon yield and narrow bandwidth. Simulations are presented on production of controllable narrow bandwidth sources using the beam and plasma capabilities of LPAs. Recent experiments and simulations demonstrate controllable LPAs in the energy range appropriate to MeV Thomson sources. Design of experiments and laser capabilities to combine these elements will be presented, towards a compact photon source system. A dedicated facility under construction will be described. Work supported by US DOE NNSA DNN R&D and by Sc. HEP under contract DE-AC02-05CH11231.

  14. Plasma breakdown diagnostics with the biased disc of electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Tarvainen, O; Ropponen, T; Toivanen, V; Arje, J; Koivisto, H [University of Jyvaeskylae, Department of Physics, Accelerator Laboratory, PO Box 35 (YFL), 40500 Jyvaeskylae (Finland)], E-mail: olli.tarvainen@jyu.fi

    2009-08-15

    The electron cyclotron resonance ion sources at the JYFL (University of Jyvaeskylae, Department of Physics) accelerator laboratory have been operated in pulsed mode to study the time-resolved current signal from the biased discs of the ion sources. The purpose of the experiments is to gain an understanding of the ion source parameters affecting the time required for the transition from neutral gas to plasma. It was observed that the plasma breakdown time depends strongly on the neutral gas density, gas species and density of seed electrons. In particular, it was observed that a low power microwave signal at secondary frequency makes the breakdown time virtually independent of the neutral gas density. The results can be utilized for operation of ECR ion sources in the so-called preglow mode. A simple qualitative model, which is in good agreement with the experiments, has been developed to interpret the results.

  15. Application of atmospheric plasma sources in growth and differentiation of plant and mammalian stem cells

    Science.gov (United States)

    Puac, Nevena

    2014-10-01

    The expansion of the plasma medicine and its demand for in-vivo treatments resulted in fast development of various plasma devices that operate at atmospheric pressure. These sources have to fulfill all demands for application on biological samples. One of the sources that meet all the requirements needed for treatment of biological material is plasma needle. Previously, we have used this device for sterilization of planctonic samples of bacteria, MRSA biofilm, for improved differentiation of human periodontal stem cells into osteogenic line and for treatment of plant meristematic cells. It is well known that plasma generates reactive oxygen species (ROS) and reactive nitrogen species (RNS) that strongly affect metabolism of living cells. One of the open issues is to correlate external plasma products (electrons, ions, RNS, ROS, photons, strong fields etc.) with the immediate internal response which triggers or induces effects in the living cell. For that purpose we have studied the kinetics of enzymes which are typical indicators of the identity of reactive species from the plasma created environment that can trigger signal transduction in the cell and ensue cell activity. In collaboration with Suzana Zivkovicm, Institute for Biological Research ``Sinisa Stankovic,'' University of Belgrade; Nenad Selakovic, Institute of Physics, University of Belgrade; Milica Milutinovic, Jelena Boljevic, Institute for Biological Research ``Sinisa Stankovic,'' University of Belgrade; and Gordana Malovic, Zoran Lj. Petrovic, Institute of Physics, University of Belgrade. Grants III41011, ON171037 and ON173024, MESTD, Serbia.

  16. Lifetime Calculations on Collector Optics from Laser Plasma Extreme Ultraviolet Sources with Minimum Mass

    Institute of Scientific and Technical Information of China (English)

    WU Tao; WANG Xin-Bing

    2011-01-01

    An ion flux and its kinetic energy spectrum are obtained using a self similar spherically symmetric fluid model of expansion of a collisionless plasma into vacuum. According to the ion flux and energy distribution, the collector optical lifetime is estimated by knowledge of the sputtering yield of conventional Mo/Si multilayer coatings for the CO2 and Nd:YAG pulsed-laser produced plasmas based on the minimum mass tin droplet target without debris mitigation. The results show that the longer wavelength of the CO2 laser produced plasma light source is more suitable for extreme ultraviolet lithography than Nd:YAG laser in respect of fast ion debris induced sputtering damage to the collector mirror.%@@ An ion flux and its kinetic energy spectrum are obtained using a self similar spherically symmetric fluid model of expansion of a collisionless plasma into vacuum.According to the ion flux and energy distribution,the collector optical lifetime is estimated by knowledge of the sputtering yield of conventional Mo/Si multilayer coatings for the CO2 and Nd:YAG pulsed-laser produced plasmas based on the minimum mass tin droplet target without debris mitigation.The results show that the longer wavelength of the CO2 laser produced plasma light source is more suitable for extreme ultraviolet lithography than Nd:YAG laser in respect of fast ion debris induced sputtering damage to the collector mirror.

  17. Atomic Layer Deposition Al2O3 Thin Films in Magnetized Radio Frequency Plasma Source

    Science.gov (United States)

    Li, Xingcun; Chen, Qiang; Sang, Lijun; Yang, Lizhen; Liu, Zhongwei; Wang, Zhenduo

    Self-limiting deposition of aluminum oxide (Al2O3) thin films were accomplished by the plasma-enhanced chemical vapor deposition using trimethyl aluminum (TMA) and O2 as precursor and oxidant, respectively, where argon was kept flowing in whole deposition process as discharge and purge gas. In here we present a novel plasma source for the atomic layer deposition technology, magnetized radio frequency (RF) plasma. Difference from the commercial RF source, magnetic coils were amounted above the RF electrode, and the influence of the magnetic field strength on the deposition rate and morphology are investigated in detail. It concludes that a more than 3 Å/ purging cycle deposition rate and the good quality of ALD Al2O3 were achieved in this plasma source even without extra heating. The ultra-thin films were characterized by including Fourier transform infrared (FTIR) spectroscopy, X-ray photoelectric spectroscopy (XPS), scanning electron microscopy (SEM), and atomic force microscopy (AFM). The high deposition rates obtained at ambient temperatures were analyzed after in-situ the diagnostic of plasmas by Langmuir probe.

  18. A Mirror-like ECR Plasma Source for Ionosphere Environment Simulator

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A compact mirror-like ECR (electron cyclotron resonance) plasma source for the ionosphere environment simulator was described for the first time in China. The overall sources system was composed of a 200 W 2.45 GHz microwave source, a coaxial 3λo/4 TEM-mode microwave resonance applicator, column and cylindrical Nd-Fe-P magnets, a quartz bell-shaped discharge chamber, a gas inlet system and a plasma-diffusing bore. The preliminary experiment demonstrated that ambi-polar diffusion plasma stream into the simulator (~500 mm long) formed an environment with following parameters: a plasma density ne of 104 cm-3 ~ 106cm-3, an electron temperature Te < 5 eV at a pressure P of 10-1 Pa~10-3 Pa, a plasma uniformity of > 80% over the experimental target with a 160-mm-in-diameter, satisfying primarily the requirement of simulating in a severe ionosphere environment.

  19. Studies of plasma breakdown and electron heating on a 14 GHz ECR ion source through measurement of plasma bremsstrahlung

    Energy Technology Data Exchange (ETDEWEB)

    Ropponen, T; Machicoane, G; Leitner, D [National Superconducting Cyclotron Laboratory, MSU, East Lansing, MI 48824 (United States); Tarvainen, O; Toivanen, V; Koivisto, H; Kalvas, T; Peura, P; Jones, P [University of Jyvaeskylae, Department of Physics, PO Box 35 (YFL), 40500 Jyvaeskylae (Finland); Izotov, I; Skalyga, V; Zorin, V [Institute of Applied Physics, RAS, 46 Ulyanov St., 603950 Nizhny Novgorod (Russian Federation); Noland, J, E-mail: tommi.ropponen@gmail.com, E-mail: olli.tarvainen@jyu.fi [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States)

    2011-10-15

    Temporal evolution of plasma bremsstrahlung emitted by a 14 GHz electron cyclotron resonance ion source (ECRIS) operated in pulsed mode is presented in the energy range 1.5-400 keV with 100 {mu}s resolution. Such a high temporal resolution together with this energy range has never been measured before with an ECRIS. Data are presented as a function of microwave power, neutral gas pressure, magnetic field configuration and seed electron density. The saturation time of the bremsstrahlung count rate is almost independent of the photon energy up to 100 keV and exhibits similar characteristics with the neutral gas balance. The average photon energy during the plasma breakdown is significantly higher than that during the steady state and depends strongly on the density of seed electrons. The results are consistent with a theoretical model describing the evolution of the electron energy distribution function during the preglow transient.

  20. Hydrogen Ionic Plasma and Particle Dynamics in Negative Ion Source for NBI

    Science.gov (United States)

    Tsumori, Katsuyoshi

    2013-10-01

    Three negative-ion-based neutral beam injectors (NBIs) have been developed for plasma heating in the Large Helical Device. The NBIs achieve successfully the nominal injection power and beam energy, and understanding of the production and transport mechanisms of H- ion is required to obtain more stable high power beam. In the ion source development, we have found hydrogen ionic plasmas with extremely low electron density are produced in the beam extraction region. The plasma is measured with a combination of an electrostatic probe, millimeter-wave interferometer and cavity ring down (CRD). It has been observed for the first time that the charge neutrality of the ionic plasma is broken with H- extraction and electrons compensate the extracted H- charge. The influence of the extraction field widely affects to the ionic plasma in the extraction region. Two-dimensional particle-in-cell simulation (2D-PIC) has been applied to investigate the particle transport and reproduces the production of the ionic plasma and electron compensation due to H- extraction. In particle model, produced H- ions leave from the Cs covered PG surface in opposite direction to beam extraction. The direction can be changed with the electric field and collective effect due to the presence of plasma. A new technique using CCD camera with H α filter applied to measure the two-dimensional distribution of H- density. In the ionic plasma, H α light is emitted via electron-impact excitation and mutual neutralization processes with H- ion and proton. Comparing the results obtained with optical emission spectroscopy, electrostatic probe and CRD, it is shown the H α emission is dominated with the mutual neutralization. By subtracting the CCD images with and without beam extraction, it becomes clear that H- ions are extracted not directly from the PG surface but from the bulk of the ionic plasma. The result suggests the initial energy of H- ion is dumped rapidly in the ionic plasma.

  1. [Experimental investigation of laser plasma soft X-ray source with gas target].

    Science.gov (United States)

    Ni, Qi-liang; Gong, Yan; Lin, Jing-quan; Chen, Bo; Cao, Jian-lin

    2003-02-01

    This paper describes a debris-free laser plasma soft X-ray source with a gas target, which has high operating frequency and can produce strong soft X-ray radiation. The valve of this light source is drived by a piezoelectrical ceramic whose operating frequency is up to 400 Hz. In comparison with laser plasma soft X-ray sources using metal target, the light source is debris-free. And it has higher operating frequency than gas target soft X-ray sources whose nozzle is controlled by a solenoid valve. A channel electron multiplier (CEM) operating in analog mode is used to detect the soft X-ray generated by the laser plasma source, and the CEM's output is fed to to a charge-sensitive preamplifier for further amplification purpose. Output charges from the CEM are proportional to the amplitude of the preamplifier's output voltage. Spectra of CO2, Xe and Kr at 8-14 nm wavelength which can be used for soft X-ray projection lithography are measured. The spectrum for CO2 consists of separate spectral lines originate mainly from the transitions in Li-like and Be-like ions. The Xe spectrum originating mainly from 4d-5f, 4d-4f, 4d-6p and 4d-5p transitions in multiply charged xenon ions. The spectrum for Kr consists of separate spectral lines and continuous broad spectra originating mainly from the transitions in Cu-, Ni-, Co- and Fe-like ions.

  2. Diagnostics of plasma decay and afterglow transient of an electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Tarvainen, O; Ropponen, T; Toivanen, V; Kalvas, T; Arje, J; Koivisto, H, E-mail: olli.tarvainen@jyu.f [University of Jyvaeskylae, Department of Physics, Accelerator Laboratory PO Box 35 (YFL), 40500 Jyvaeskylae (Finland)

    2010-08-15

    The electron cyclotron resonance ion sources at the JYFL (University of Jyvaeskylae, Department of Physics) accelerator laboratory have been operated in pulsed mode to study the decay of bremsstrahlung emission and ion beam currents of different charge states. The purpose of the experiments is to gain understanding on the ion source parameters affecting the afterglow. It was observed that the bremsstrahlung emission characteristics during the afterglow and decay times of extracted ion beam currents are virtually independent of the ion source tuning parameters. The decay time of different charge states was found to be almost inversely proportional to the square of the ion charge. The result is in good agreement with a simple theoretical model based on diffusion of ions from the magnetic field of the ion source. It was observed that the plasma decay time is shorter in the case of the ion source with lower operation frequency and, thus, lower magnetic field strength. The scaling between the ion sources supports a model based on Bohm diffusion, arising from non-linear effects such as instabilities and fluctuating fields in turbulent plasma. The experiments provide information on the mechanisms causing instabilities during the plasma decay.

  3. Amorphous carbon film deposition on inner surface of tubes using atmospheric pressure pulsed filamentary plasma source

    CERN Document Server

    Pothiraja, Ramasamy; Awakowicz, Peter

    2011-01-01

    Uniform amorphous carbon film is deposited on the inner surface of quartz tube having the inner diameter of 6 mm and the outer diameter of 8 mm. A pulsed filamentary plasma source is used for the deposition. Long plasma filaments (~ 140 mm) as a positive discharge are generated inside the tube in argon with methane admixture. FTIR-ATR, XRD, SEM, LSM and XPS analyses give the conclusion that deposited film is amorphous composed of non-hydrogenated sp2 carbon and hydrogenated sp3 carbon. Plasma is characterized using optical emission spectroscopy, voltage-current measurement, microphotography and numerical simulation. On the basis of observed plasma parameters, the kinetics of the film deposition process is discussed.

  4. Microwave frequency sweep interferometer for plasma density measurements in ECR ion sources: Design and preliminary results

    Science.gov (United States)

    Torrisi, Giuseppe; Mascali, David; Neri, Lorenzo; Leonardi, Ornella; Sorbello, Gino; Celona, Luigi; Castro, Giuseppe; Agnello, Riccardo; Caruso, Antonio; Passarello, Santi; Longhitano, Alberto; Isernia, Tommaso; Gammino, Santo

    2016-02-01

    The Electron Cyclotron Resonance Ion Sources (ECRISs) development is strictly related to the availability of new diagnostic tools, as the existing ones are not adequate to such compact machines and to their plasma characteristics. Microwave interferometry is a non-invasive method for plasma diagnostics and represents the best candidate for plasma density measurement in hostile environment. Interferometry in ECRISs is a challenging task mainly due to their compact size. The typical density of ECR plasmas is in the range 1011-1013 cm-3 and it needs a probing beam wavelength of the order of few centimetres, comparable to the chamber radius. The paper describes the design of a microwave interferometer developed at the LNS-INFN laboratories based on the so-called "frequency sweep" method to filter out the multipath contribution in the detected signals. The measurement technique and the preliminary results (calibration) obtained during the experimental tests will be presented.

  5. Ion beam extraction from a matrix ECR plasma source by discrete ion-focusing effect

    DEFF Research Database (Denmark)

    Stamate, Eugen; Draghici, Mihai

    2010-01-01

    Positive or negative ion beams extracted from plasma are used in a large variety of surface functionalization techniques such as implantation, etching, surface activation, passivation or oxidation. Of particular importance is the surface treatment of materials sensitive to direct plasma exposure...... due to high heath fluxes, the controllability of the ion incidence angle, and charge accumulation when treating insulating materials. Despite of a large variety of plasma sources available for ion beam extraction, there is a clear need for new extraction mechanisms that can make available ion beams...... with high current densities that can treat surfaces placed adjacent to the extraction region. This work introduces a new phenomenology for ion beam extraction using the discrete ion-focusing effect associated with three-dimensional plasma-sheath-lenses [1, 2]. Experiments are performed in a matrix...

  6. Porcelain-coated antenna for radio-frequency driven plasma source

    Science.gov (United States)

    Leung, Ka-Ngo; Wells, Russell P.; Craven, Glen E.

    1996-01-01

    A new porcelain-enamel coated antenna creates a clean plasma for volume or surface-conversion ion sources. The porcelain-enamel coating is hard, electrically insulating, long lasting, non fragile, and resistant to puncture by high energy ions in the plasma. Plasma and ion production using the porcelain enamel coated antenna is uncontaminated with filament or extraneous metal ion because the porcelain does not evaporate and is not sputtered into the plasma during operation. Ion beams produced using the new porcelain-enamel coated antenna are useful in ion implantation, high energy accelerators, negative, positive, or neutral beam applications, fusion, and treatment of chemical or radioactive waste for disposal. For ion implantation, the appropriate species ion beam generated with the inventive antenna will penetrate large or small, irregularly shaped conducting objects with a narrow implantation profile.

  7. Microwave frequency sweep interferometer for plasma density measurements in ECR ion sources: Design and preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Torrisi, Giuseppe [INFN - Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); University Mediterranea of Reggio Calabria, Reggio Calabria (Italy); Mascali, David; Neri, Lorenzo; Leonardi, Ornella; Celona, Luigi; Castro, Giuseppe; Agnello, Riccardo; Caruso, Antonio; Passarello, Santi; Longhitano, Alberto; Gammino, Santo [INFN - Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); Sorbello, Gino [INFN - Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); University of Catania, Catania, Italy and INFN-LNS, Catania (Italy); Isernia, Tommaso [University Mediterranea of Reggio Calabria, Reggio Calabria (Italy)

    2016-02-15

    The Electron Cyclotron Resonance Ion Sources (ECRISs) development is strictly related to the availability of new diagnostic tools, as the existing ones are not adequate to such compact machines and to their plasma characteristics. Microwave interferometry is a non-invasive method for plasma diagnostics and represents the best candidate for plasma density measurement in hostile environment. Interferometry in ECRISs is a challenging task mainly due to their compact size. The typical density of ECR plasmas is in the range 10{sup 11}–10{sup 13} cm{sup −3} and it needs a probing beam wavelength of the order of few centimetres, comparable to the chamber radius. The paper describes the design of a microwave interferometer developed at the LNS-INFN laboratories based on the so-called “frequency sweep” method to filter out the multipath contribution in the detected signals. The measurement technique and the preliminary results (calibration) obtained during the experimental tests will be presented.

  8. A Simulator for Producing of High Flux Atomic Oxygen Beam by Using ECR Plasma Source

    Institute of Scientific and Technical Information of China (English)

    Shuwang DUO; Meishuan LI; Yaming ZHANG

    2004-01-01

    In order to study the atomic oxygen corrosion of spacecraft materials in low earth orbit environment, an atomic oxygen simulator was established. In the simulator, a 2.45 GHz microwave source with maximum power of 600 W was launched into the circular cavity to generate ECR (electron cyclotron resonance) plasma. The oxygen ion beam moved onto a negatively biased Mo plate under the condition of symmetry magnetic mirror field confine, then was neutralized and reflected to form oxygen atom beam. The properties of plasma density, electron temperature, plasma space potential and ion incident energy were characterized. The atomic oxygen beam flux was calibrated by measuring the mass loss rate of Kapton during the atomic 5~30 eV and a cross section of φ80 mm could be obtained under the operating pressure of 10-1~10-3 Pa. Such a high flux source can provide accelerated simulation tests of materials and coatings for space applications.

  9. Measurement of the Internal Magnetic Field of Plasmas using an Alpha Particle Source

    Energy Technology Data Exchange (ETDEWEB)

    S.J. Zweben; D.S. Darrow; P.W. Ross; J.L. Lowrance; G. Renda

    2004-05-13

    The internal magnetic fields of plasmas can be measured under certain conditions from the integrated v x B deflection of MeV alpha particles emitted by a small radioactive source. This alpha source and large-area alpha particle detector would be located inside the vacuum vessel but outside the plasma. Alphas with a typical energy of 5.5 MeV (241Am) can reach the center of almost all laboratory plasmas and magnetic fusion devices, so this method can potentially determine the q(r) profile of tokamaks or STs. Orbit calculations, background evaluations, and conceptual designs for such a vxB (or ''AVB'') detector are described.

  10. Laser-plasma electron accelerator for all-optical inverse Compton X-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Koyama, K. [University of Tokyo, 2-22 Shirakata shirane, Tokai-mura, Naka-gun, Ibaraki 319-1188 (Japan)], E-mail: koyama@nuclear.jp; Yamazaki, A.; Maekawa, A.; Uesaka, M. [University of Tokyo, 2-22 Shirakata shirane, Tokai-mura, Naka-gun, Ibaraki 319-1188 (Japan); Hosokai, T. [Tokyo Institute of Technology, 4259 Nagatsuda-cho, Midori-ku, Yokohama 226-8503 (Japan); Miyashita, M. [Tokyo University of Science, 2641 Yamazaki, Noda, Chiba 278-8510 (Japan); Masuda, S.; Miura, E. [AIST, Tsukuba-central-2, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan)

    2009-09-01

    Inverse Compton scattering has been gaining attention as a process for the generation of X/{gamma}-ray, since it produces tunable X/{gamma}-ray pulses with a small cone angle of radiation. A table-top tunable Compton X/{gamma}-ray source would be realized by replacing a radio frequency (rf) linac with a laser wakefield accelerator (LWFA), which is one of the advanced accelerators. An empirical scaling law for the LWFA in the self-injection mode showed that the energy gain was inversely proportional to the plasma density. In order to effectively employ the LWFA as a Compton X/{gamma}-ray source, its stability must be improved. For this purpose, we are developing techniques for the injection of initial electrons by a localized wavebreaking at the density ramp of a plasma. The pointing stability and acceleration efficiency of the electron beam were significantly improved by applying an axial magnetic field to the plasma channel.

  11. Laser-Plasma Sources for Soft-X-Ray Projection Lithography

    NARCIS (Netherlands)

    F. Bijkerk,; Shmaenok, L.; Vanhonk, A.; Bastiaensen, R.; Platonov, Y. Y.; Shevelko, A. P.; Mitrofanov, A. V.; Voss, F.; Desor, R.; Frowein, H.; Nikolaus, B.

    1994-01-01

    Results are reported concerning high-repetition-rate excimer lasers with average powers up to 415 W and their usage for generating laser-plasma soft X-ray sources. A conversion efficiency of laser light into monochromatized soft X-ray radiation of 0.7% at 13.5 nm (2% bandwidth) was achieved using an

  12. Study of the general plasma characteristics of a high power multifilament ion source

    Energy Technology Data Exchange (ETDEWEB)

    Schoenberg, K.F.

    1979-09-01

    A general assessment of the steady state and time dependent plasma properties which characterize a high power multifilament ion source is presented. Steady state measurements, obtained via a pulsed electrostatic probe data acquisition system, are described. Fluctuation measurements, obtained via a broadband digital spectral analysis system, are also given.

  13. Finite element analysis of keyhole plasma arc welding based on an adaptive heat source mode

    Institute of Scientific and Technical Information of China (English)

    Hu Qingxian; Wu Chuansong; Zhang Yuming

    2007-01-01

    An adaptive heat source mode is proposed to account for the keyhole effect and the characteristics of volumetric distribution along the direction of the workpiece thickness. Finite element analysis of the temperature field in keyhole plasma arc welding is conducted and the weld geometry is obtained. The predicted results are in agreement with the measured ones.

  14. Laser-Plasma Sources for Soft-X-Ray Projection Lithography

    NARCIS (Netherlands)

    F. Bijkerk,; Shmaenok, L.; Vanhonk, A.; Bastiaensen, R.; Platonov, Y. Y.; Shevelko, A. P.; Mitrofanov, A. V.; Voss, F.; Desor, R.; Frowein, H.; Nikolaus, B.

    1994-01-01

    Results are reported concerning high-repetition-rate excimer lasers with average powers up to 415 W and their usage for generating laser-plasma soft X-ray sources. A conversion efficiency of laser light into monochromatized soft X-ray radiation of 0.7% at 13.5 nm (2% bandwidth) was achieved using an

  15. Surface science in hernioplasty: The role of plasma treatments

    Science.gov (United States)

    Nisticò, Roberto; Magnacca, Giuliana; Martorana, Selanna

    2017-10-01

    The aim of this review is to clarify the importance of surface modifications induced in biomaterials for hernia-repair application. Starting from the pioneering experiences involving proto-materials as ancient prosthesis, a historical excursus between the biomaterials used in hernioplasty was realized. Subsequently, after the revolutionary discovery of stereoregular polymerization followed by the PP application in the biomedical field performed by the surgeon F. Usher, a comparative study on different hernia-repair meshes available was realized in order to better understand all the outstanding problems and possible future developments. Furthermore, since many unsolved problems on prosthetic devices implantation are linked to phenomena occurring at the interface between the biomaterials surface and the body fluids, the importance of surface science in hernioplasty was highlighted and case studies of new surface-modified generations of prosthesis presented. The results discussed in the following evidence how the surface study are becoming increasingly important for a proper knowledge of issues related to the interaction between the living matter and the artificial prostheses.

  16. Evolution of plasma parameters in an Ar-N2/He inductive plasma source with magnetic pole enhancement

    Science.gov (United States)

    Maria, Younus; N, U. Rehman; M, Shafiq; M, Naeem; M, Zaka-Ul-Islam; M, Zakaullah

    2017-02-01

    Magnetic pole enhanced inductively coupled plasmas (MaPE-ICPs) are a promising source for plasma-based etching and have a wide range of material processing applications. In the present study Langmuir probe and optical emission spectroscopy were used to monitor the evolution of plasma parameters in a MaPE-ICP Ar-N2/He mixture plasma. Electron density ({n}{{e}}) and temperature ({T}{{e}}), excitation temperature ({T}{{exc}}), plasma potential ({V}{{p}}), skin depth (δ ) and the evolution of the electron energy probability function (EEPF) are reported as a function of radiofrequency (RF) power, pressure and argon concentration in the mixture. It is observed that {n}{{e}} increases while {T}{{e}} decreases with increase in RF power and argon concentration in the mixture. The emission intensity of the argon line at 750.4 nm is also used to monitor the variation of the ‘high-energy tail’ of the EEPF with RF power and gas pressure. The EEPF has a ‘bi-Maxwellian’ distribution at low RF powers and higher pressure in a pure {{{N}}}2 discharge. However, it evolves into a ‘Maxwellian’ distribution at RF powers greater than 70 W for pure {{{N}}}2, and at 50 W for higher argon concentrations in the mixture. The effect of argon concentration on the temperatures of two electron groups in the ‘bi-Maxwellian’ EEPF is examined. The temperature of the low-energy electron group {T}{{L}} shows a decreasing trend with argon addition until the ‘thermalization’ of the two temperatures occurs, while the temperature of high-energy electrons {T}{{H}} decreases continuously.

  17. High-power EUV lithography sources based on gas discharges and laser-produced plasmas

    Science.gov (United States)

    Stamm, Uwe; Ahmad, Imtiaz; Balogh, Istvan; Birner, H.; Bolshukhin, D.; Brudermann, J.; Enke, S.; Flohrer, Frank; G„bel, Kai; G÷tze, S.; Hergenhan, G.; Kleinschmidt, J.'rgen; Kl÷pfel, Diethard; Korobotchko, Vladimir; Ringling, Jens; Schriever, Guido; Tran, C. D.; Ziener, C.

    2003-06-01

    Semiconductor chip manufacturers are expecting to use extreme UV lithography for production in 2009. EUV tools require high power, brilliant light sources at 13.5 nm with collector optics producing 120 W average power at entrance of the illuminator system. Today the power and lifetime of the EUV light source are considered as the most critical issue for EUV lithography. The present paper gives an update of the development status of EUV light sources at XTREME technologies, a joint venture of Lambda Physik AG, Goettingen, and Jenoptik LOS GmbH, Jena, Germany. Results on both laser produced plasma (LPP) and gas discharge produced plasma (GDPP), the two major technologies in EUV sources, are given. The LPP EUV sources use xenon-jet target systems and pulsed lasers with 400 W average power at 10 kHz developed at XTREME technologies. The maximum conversion efficiency form laser power into EUV in-band power is 0.75% into 2π solid angle. With 300 W laser average power at 3300 Hz repetition rate up to 1.5 W EUV radiation is generated at 13.5 nm. After a collector of 5 sr this corresponds to 0.6 W in intermediate focus without spectral purity filter and 0.5 W in intermediate focus with spectral purity filter. The direct generation of the EUV emitting plasma from electrical discharges is much simpler than LPP because the electrical energy has not to be converted into laser radiation before plasma excitation. XTREME technologies' Xenon GDPP EUV sources use the Z-pinch principle with efficient sliding discharge pre-ionization. The plasma pinch size and the available emission angle have been matched to the etendue of the optical system of 2-3 mm2 sr, i.e. no additional etendue related loss reduces the usable EUV power from the source. In continuous operation at 1000 Hz the GDPP sources emit 50W into 2π solid angle are obtained from the Z-pinch sources. Spatial and temporal emission stability of the EUV sources is in the range of a few percent. Debris shields for EUV sources

  18. Detailed beam and plasma measurements on the vessel for extraction and source plasma analyses (VESPA) Penning H{sup −} ion source

    Energy Technology Data Exchange (ETDEWEB)

    Lawrie, S. R., E-mail: scott.lawrie@stfc.ac.uk [STFC ISIS Pulsed Spallation Neutron and Muon Facility, Rutherford Appleton Laboratory, Harwell, Oxford (United Kingdom); John Adams Institute of Accelerator Science, University of Oxford, Oxford (United Kingdom); Faircloth, D. C.; Letchford, A. P.; Whitehead, M. O.; Wood, T. [STFC ISIS Pulsed Spallation Neutron and Muon Facility, Rutherford Appleton Laboratory, Harwell, Oxford (United Kingdom)

    2016-02-15

    A vessel for extraction and source plasma analyses (VESPA) is operational at the Rutherford Appleton Laboratory (RAL). This project supports and guides the overall ion source R&D effort for the ISIS spallation neutron and muon facility at RAL. The VESPA produces 100 mA of pulsed H{sup −} beam, but perveance scans indicate that the source is production-limited at extraction voltages above 12 kV unless the arc current is increased. A high resolution optical monochromator is used to measure plasma properties using argon as a diagnostic gas. The atomic hydrogen temperature increases linearly with arc current, up to 2.8 eV for 50 A; whereas the electron temperature has a slight linear decrease toward 2.2 eV. The gas density is 10{sup 21} m{sup −3}, whilst the electron density is two orders of magnitude lower. Densities follow square root relationships with arc current, with gas density decreasing whilst electron (and hence ion) density increases. Stopping and range of ions in matter calculations prove that operating a high current arc with an argon admixture is extremely difficult because cathode-coated cesium is heavily sputtered by argon.

  19. Ambipolar and non-ambipolar diffusion in an rf plasma source containing a magnetic filter

    Energy Technology Data Exchange (ETDEWEB)

    Lafleur, T., E-mail: trevor.lafleur@lpp.polytechnique.fr [Laboratoire de Physique des Plasmas, CNRS, Sorbonne Universités, UPMC Univ Paris 06, Univ Paris-Sud, Ecole Polytechnique, 91128 Palaiseau (France); ONERA-The French Aerospace Lab, 91120 Palaiseau (France); Aanesland, A. [Laboratoire de Physique des Plasmas, CNRS, Sorbonne Universités, UPMC Univ Paris 06, Univ Paris-Sud, Ecole Polytechnique, 91128 Palaiseau (France)

    2014-06-15

    By placing a magnetic filter across a rectangular plasma source (closed at one end with a ceramic plate and an rf antenna, and terminated at the opposite end by a grounded grid), we experimentally investigate the effect of conducting and insulating source walls on the nature of the plasma diffusion phenomena. The use of a magnetic filter creates a unique plasma, characterized by a high upstream electron temperature (T{sub e{sub u}}∼5 eV) near the rf antenna and a low downstream electron temperature (T{sub e{sub d}}∼1 eV) near the grid, which more clearly demonstrates the role of the source wall materials. For conducting walls a net ion current to ground is measured on the grid, and the plasma potential is determined by a mean electron temperature within the source. For insulating walls the plasma potential is determined by the downstream electron temperature (i.e., V{sub p}∼5.2T{sub e{sub d}} in argon), and the net current to the grid is exactly zero. Furthermore, by inserting a small additional upstream conductor (that can be made floating or grounded through an external circuit switch), we demonstrate that the plasma potential can be controlled and set to a low (V{sub p}∼5.2T{sub e{sub d}}), or high (V{sub p}∼5.2T{sub e{sub u}}) value.

  20. Plasma source by microwaves: design description; Fuente de plasma por microondas: descripcion de diseno

    Energy Technology Data Exchange (ETDEWEB)

    Camps, E.; Olea, O.; Andrade, R.; Anguiano, G

    1992-03-15

    The design of a device for the formation of a plasma with densities of the order of 10{sup 12} cm{sup -} {sup 3} and low temperatures (T{sub e} {approx} 40 eV) is described. For such purpose it was carried out in the device a microwave discharge (f{sub o} = 2.45 GHz) in a resonator of high Q factor, immersed in a static external magnetic field. The device worked in the regime {omega}{sub ce} {<=} {omega}{sub o}/2 ({omega}{sub ce}- cyclotron frequency of the electrons, ({omega}{sub o} = 2 {pi} f{sub o}) where is possible the excitement of non lineal phenomena of waves transformation. (Author)

  1. X-ray imaging and imaging spectroscopy of fusion plasmas and light-source experiments with spherical optics and pixel array detectors

    Science.gov (United States)

    Hill, K. W.; Bitter, M.; Delgado-Aparicio, L.; Pablant, N. A.; Beiersdorfer, P.; Sanchez del Rio, M.; Zhang, L.

    2012-10-01

    High resolution (λ/Δλ ~10,000) 1D imaging x-ray spectroscopy using a spherically bent crystal and a 2D hybrid pixelarray detector (PAD) is used world wide for Doppler measurements of ion-temperature (Ti) and plasma flow-velocityprofiles in magnetic confinement fusion (MCF) plasmas. Meter sized plasmas are diagnosed with cm spatial resolution and 10 ms time resolution. This concept can also be used as a diagnostic of small sources, such as inertial confinement fusion (ICF) plasmas and targets on x-ray light source beam lines, with spatial resolution of microns. A new concept of using matched pairs of spherically bent crystals for monochromatic stigmatic 2D x-ray imaging of mm sized sources offers the possibility of spatial resolution of microns and large solid angle, relative to that achieved with pinhole imaging. Other potential applications of the 2D imaging schemes include x-ray lithography and x-ray microscopy for biological and materials science research. Measurements from MFE plasmas, as well as laboratory experiments and ray tracing computations validating the 1D imaging spectroscopy and 2D x-ray imaging techniques will be presented.

  2. Science Study Aids 3: Carbohydrates - Nature's Energy Source.

    Science.gov (United States)

    McConnell, Bill

    This publication is the third of a series of seven supplementary investigative materials for use in secondary science classes providing up-to-date research-related investigations. This unit is structured for grade levels 7 through 12. It is concerned with the role of carbohydrates as important nutrients for consumers. This guide will enable…

  3. Open Source Software Alternatives in Higher Education Following Computer Science Curricula 2013

    Directory of Open Access Journals (Sweden)

    Borislav Stoyanov

    2014-09-01

    Full Text Available In this study we overview the open source software, describe the advantages and disadvantages of using open source software in modern Higher Education following Computer Science Curricula 2013. The study’s main purposes are to clear the understanding of open source software, to present alternatives of the commercial software and demonstrate the potential benefits of integrating open source software in Higher Education.

  4. Measurements and modeling of the impact of weak magnetic fields on the plasma properties of a planar slot antenna driven plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Jun, E-mail: jun.yoshikawa@tel.com; Susa, Yoshio; Ventzek, Peter L. G. [Tokyo Electron Ltd., Akasaka Biz Tower, 3-1 Akasaka 5-chome, Minato-ku, Tokyo 107-6325 (Japan)

    2015-05-15

    The radial line slot antenna plasma source is a type of surface wave plasma source driven by a planar slot antenna. Microwave power is transmitted through a slot antenna structure and dielectric window to a plasma characterized by a generation zone adjacent to the window and a diffusion zone that contacts a substrate. The diffusion zone is characterized by a very low electron temperature. This renders the source useful for soft etch applications and thin film deposition processes requiring low ion energy. Another property of the diffusion zone is that the plasma density tends to decrease from the axis to the walls under the action of ambipolar diffusion at distances far from where the plasma is generated. A previous simulation study [Yoshikawa and. Ventzek, J. Vac. Sci. Technol. A 31, 031306 (2013)] predicted that the anisotropy in transport parameters due to weak static magnetic fields less than 50 G could be leveraged to manipulate the plasma profile in the radial direction. These simulations motivated experimental tests in which weak magnetic fields were applied to a radial line slot antenna source. Plasma absorption probe measurements of electron density and etch rate showed that the magnetic fields remote from the wafer were able to manipulate both parameters. A summary of these results is presented in this paper. Argon plasma simulation trends are compared with experimental plasma and etch rate measurements. A test of the impact of magnetic fields on charge up damage showed no perceptible negative effect.

  5. Deep UV Semiconductor Sources for Advanced Planetary Science Instruments Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal addresses the need for miniature, narrow-linewidth, deep UV optical sources that operate at very low ambient temperatures for use in advanced in situ...

  6. Biological stimulation of the Human skin applying health promoting light and plasma sources

    Energy Technology Data Exchange (ETDEWEB)

    Awakowicz, P.; Bibinov, N. [Center for Plasma Science and Technology, Ruhr-University, Bochum (Germany); Born, M.; Niemann, U. [Philips Research, Aachen (Germany); Busse, B. [Zell-Kontakt GmbH, Noerten-Hardenberg (Germany); Gesche, R.; Kuehn, S.; Porteanu, H.E. [Ferdinand-Braun-Institut fuer Hoechstfrequenztechnik, Berlin (Germany); Helmke, A. [University of Applied Sciences and Arts, Goettingen (Germany); Kaemling, A.; Wandke, D. [CINOGY GmbH, Duderstadt (Germany); Kolb-Bachofen, V.; Liebmann, J. [Institute for Immunobiology, Heinrich-Heine University, Duesseldorf (Germany); Kovacs, R.; Mertens, N.; Scherer, J. [Aurion Anlagentechnik GmbH, Seligenstadt (Germany); Oplaender, C.; Suschek, C. [Clinic for Plastic Surgery, University Clinic, Aachen (Germany); Vioel, W. [Laser-Laboratorium, Goettingen (Germany); University of Applied Sciences and Arts, Goettingen (Germany)

    2009-10-15

    In the frame of BMBF project ''BioLiP'', new physical treatment techniques aiming at medical treatment of the human skin have been developed. The acronym BioLiP stands for ''Desinfektion, Entkeimung und biologische Stimulation der Haut durch gesundheitsfoerdernde Licht- und Plasmaquellen'' (Disinfection, germ reduction and biological stimulation of the human skin by health promoting light and plasma sources). A source applying a low-temperature dielectric barrier discharge plasma (DBD) has been investigated on its effectiveness for skin disinfection and stimulation of biological material. Alternatively an atmospheric plasma source consisting of a microwave resonator combined with a solid state power oscillator has been examined. This concept which allows for a compact and efficient design avoiding external microwave power supply and matching units has been optimized with respect to nitrogen monoxide (NO) production in high yields. In both cases various application possibilities in the medical and biological domain are opened up. Light sources in the visible spectral range have been investigated with respect to the proliferation of human cell types. Intensive highly selective blue light sources based on LED technology can slow down proliferation rates without inducing toxic effects which offers new opportunities for treatments of so-called hyperproliferative skin conditions (e.g. with psoriasis or in wound healing) using UV-free light. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  7. A compact tunable polarized X-ray source based on laser-plasma helical undulators

    CERN Document Server

    Luo, Ji; Zeng, Ming; Vieira, Jorge; Yu, Lu-Le; Weng, Su-Ming; Silva, Luis O; Jaroszynski, Dino A; Sheng, Zheng-Ming; Zhang, Jie

    2016-01-01

    Laser wakefield accelerators have great potential as the basis for next generation compact radiation sources because their accelerating gradients are three orders of magnitude larger than traditional accelerators. However, X-ray radiation from such devices still lacks of tunability, especially the intensity and polarization distribution. Here we propose a tunable polarized radiation source from a helical plasma undulator based on plasma channel guided wakefield accelerator. When a laser pulse is initially incident with a skew angle relative to the channel axis, the laser and accelerated electrons experience collective spiral motions, which leads to elliptically polarized synchrotron-like radiation with flexible tunability on radiation intensity, spectra and polarization. We demonstrate that a radiation source with millimeter size and peak brilliance of $2\\times10^{19} photons/s/mm^{2}/mrad^{2}/0.1%$ bandwidth can be made with moderate laser and electron beam parameters. This brilliance is comparable with the ...

  8. Three-Dimensional Numerical Simulation of Surface-Wave Plasma Source

    Institute of Scientific and Technical Information of China (English)

    LAN Chaohui; CHEN Zhaoquan; LIU Minghai; JIANG Zhonghe; HU Xiwei

    2009-01-01

    A three-dimensional model of a surface-wave plasma(SWP)source is built numerically using the finite-difference time-domain(FDTD)method to investigate the structure of the surface wave propagation along the plasma-dielectric interface and the distributions of electromagnetic fields in the whole system.A good-performance excitation source technique for the waveguide which is pivotal to the simulation is presented.The technique can avoid the dc distortions of magnetic fields caused by the forcing electric wall.An example of simulation is given to confirm the existence of the surface waves.The simulation also shows that the code developed is a useful tool in the computer-aided design of the antenna of the SWP source.

  9. Ion Source for Neutral beam injection meant for plasma and magnetic field diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Vainionpaa, Jaakko Hannes; Leung, Ka Ngo; Gough, Richard A.; Kwan, Joe W.; Levinton, Fred

    2007-06-01

    At the Lawrence Berkeley National Laboratory (LBNL) a diagnostic neutral beam injection system for measuring plasma parameters, flow velocity, and local magnetic field is being developed. The systems is designed to have a 90 % proton fraction and small divergence with beam current at 5-6 A and a pulse length of {approx}1 s occurring once every 1-2 min. The ion source needs to generate uniform plasma over a large (8 cm x 5 cm) extraction area. For this application, we have compared RF driven multicusp ion sources operating with either an external or an internal antenna in similar ion source geometry. The ion beam will be made of an array of six sheet-shaped beamlets. The design is optimized using computer simulation programs.

  10. Plasma Outages in Pulsed, High-Power RF Hydrogen Ion Sources

    Science.gov (United States)

    Stockli, Martin; Han, Baoxi; Murray, Syd; Pennisi, Terry; Piller, Chip; Santana, Manuel; Welton, Robert

    2011-04-01

    Pulsed, high-power RF ion sources are needed to produce copious amounts of negative H-ions for high-power accelerators with charge-changing injection schemes. When increasing the RF power, the plasma inductance changes the RF resonance, which drifts away from the low-power resonance. When the RF circuit is tuned to maximize the (pulsed) plasma power, the (off-resonance) power at the beginning of the pulse is reduced. If the induced electric fields fall below the breakdown strength of the hydrogen gas, the plasma fails to develop. This can be avoided with a compromise tune and/or by increasing the inductance of the resonant circuit. However, the breakdown strength of the hydrogen gas increases with time due to the gradual decrease of the electron-rich plasma impurities, which causes plasma outages after weeks of reliable operation. In this paper we discuss the success of different mitigations that were tested and implemented to overcome this fundamental problem of pulsed, high-power RF hydrogen ion sources.

  11. Dentistry & Oral Sciences Source (DOSS): a collection for dental research and education.

    Science.gov (United States)

    Swogger, Susan E; Samsky, Monica

    2014-01-01

    Dentistry & Oral Sciences Source from EBSCO Information Services provides indexing and full-text access to an extensive selection of dental journal literature, as well some full-text dental monographs. As stated by EBSCO, titles are chosen from those commonly held in dental school libraries. The database aims to support practitioners, researchers, and advanced dental education. This column includes sample searches from Dentistry & Oral Sciences Source as well as a discussion of its special content and features.

  12. Selecting and Using Information Sources: Source Preferences and Information Pathways of Israeli Library and Information Science Students

    Science.gov (United States)

    Bronstein, Jenny

    2010-01-01

    Introduction: The study investigated the source preference criteria of library and information science students for their academic and personal information needs. Method: The empirical study was based on two methods of data collection. Eighteen participants wrote a personal diary for four months in which they recorded search episodes and answered…

  13. Pulsed, Inductively Generated, Streaming Plasma Ion Source for Heavy Ion Fusion Linacs

    Energy Technology Data Exchange (ETDEWEB)

    Steven C. Glidden; Howard D Sanders; John B. Greenly; Daniel L. Dongwoo

    2006-04-28

    This report describes a compact, high current density, pulsed ion source, based on electrodeless, inductively driven gas breakdown, developed to meet the requirements on normalized emittance, current density, uniformity and pulse duration for an ion injector in a heavy-ion fusion driver. The plasma source produces >10 μs pulse of Argon plasma with ion current densities >100 mA/cm2 at 30 cm from the source and with strongly axially directed ion energy of about 80 eV, and sub-eV transverse temperature. The source has good reproducibility and spatial uniformity. Control of the current density during the pulse has been demonstrated with a novel modulator coil method which allows attenuation of the ion current density without significantly affecting the beam quality. This project was carried out in two phases. Phase 1 used source configurations adapted from light ion sources to demonstrate the feasibility of the concept. In Phase 2 the performance of the source was enhanced and quantified in greater detail, a modulator for controlling the pulse shape was developed, and experiments were conducted with the ions accelerated to >40 kV.

  14. An Optical Streak Diagnostic for Observing Anode-Cathode Plasmas for Radiographic Source Development

    Energy Technology Data Exchange (ETDEWEB)

    Droemer, Darryl W. [National Security Technologies, LLC; Crain, Marlon D.; Lare, Gregory A. [National Security Technologies, LLC; Bennett, Nichelle L. [National Security Technologies, LLC; Johnston, Mark D. [Sandia National Laboratories

    2013-06-13

    National Security Technologies, LLC, and Sandia National Laboratories are collaborating in the development of pulsed power–driven flash x-ray radiographic sources that utilize high-intensity electron beam diodes. The RITS 6 (Radiographic Integrated Test Stand) accelerator at Sandia is used to drive a self magnetic pinch diode to produce a Bremsstrahlung x-ray source. The high electric fields and current densities associated with these short A-K gap pinch beam diodes present many challenges in diode development. Plasmas generated at both the anode and cathode affect the diode performance, which is manifested in varying spot (source) sizes, total dose output, and impedance profiles. Understanding the nature of these plasmas including closure rates and densities is important in modeling their behavior and providing insight into their mitigation. In this paper we describe a streak camera–based optical diagnostic that is capable of observing and measuring plasma evolution within the A-K gap. By imaging a region of interest onto the input slit of a streak camera, we are able to produce a time-resolved one-dimensional image of the evolving plasma. Typical data are presented.

  15. L-shell spectroscopic diagnostics of radiation from krypton HED plasma sources

    Science.gov (United States)

    Petkov, E. E.; Safronova, A. S.; Kantsyrev, V. L.; Shlyaptseva, V. V.; Rawat, R. S.; Tan, K. S.; Beiersdorfer, P.; Hell, N.; Brown, G. V.

    2016-11-01

    X-ray spectroscopy is a useful tool for diagnosing plasma sources due to its non-invasive nature. One such source is the dense plasma focus (DPF). Recent interest has developed to demonstrate its potential application as a soft x-ray source. We present the first spectroscopic studies of krypton high energy density plasmas produced on a 3 kJ DPF device in Singapore. In order to diagnose spectral features, and to obtain a more comprehensive understanding of plasma parameters, a new non-local thermodynamic equilibrium L-shell kinetic model for krypton was developed. It has the capability of incorporating hot electrons, with different electron distribution functions, in order to examine the effects that they have on emission spectra. To further substantiate the validity of this model, it is also benchmarked with data gathered from experiments on the electron beam ion trap (EBIT) at Lawrence Livermore National Laboratory, where data were collected using the high resolution EBIT calorimeter spectrometer.

  16. L-shell spectroscopic diagnostics of radiation from krypton HED plasma sources

    Energy Technology Data Exchange (ETDEWEB)

    Petkov, E. E., E-mail: emilp@unr.edu; Safronova, A. S.; Kantsyrev, V. L.; Shlyaptseva, V. V. [University of Nevada, Reno, Nevada 89557 (United States); Rawat, R. S.; Tan, K. S. [National Institute of Education, Nanyang Technological University, Singapore 637616 (Singapore); Beiersdorfer, P.; Brown, G. V. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Hell, N. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Dr. Remeis-Sternwarte and ECAP, Universität Erlangen-Nürnberg, 96049 Bamberg (Germany)

    2016-11-15

    X-ray spectroscopy is a useful tool for diagnosing plasma sources due to its non-invasive nature. One such source is the dense plasma focus (DPF). Recent interest has developed to demonstrate its potential application as a soft x-ray source. We present the first spectroscopic studies of krypton high energy density plasmas produced on a 3 kJ DPF device in Singapore. In order to diagnose spectral features, and to obtain a more comprehensive understanding of plasma parameters, a new non-local thermodynamic equilibrium L-shell kinetic model for krypton was developed. It has the capability of incorporating hot electrons, with different electron distribution functions, in order to examine the effects that they have on emission spectra. To further substantiate the validity of this model, it is also benchmarked with data gathered from experiments on the electron beam ion trap (EBIT) at Lawrence Livermore National Laboratory, where data were collected using the high resolution EBIT calorimeter spectrometer.

  17. Laser-plasma accelerator and femtosecond photon sources-based ultrafast radiation chemistry and biophysics

    Science.gov (United States)

    Gauduel, Y. A.

    2017-02-01

    The initial distribution of energy deposition triggered by the interaction of ionizing radiations (far UV and X rays, electron, proton and accelerated ions) with molecular targets or integrated biological systems is often decisive for the spatio-temporal behavior of radiation effects that take place on several orders of magnitude. This contribution deals with an interdisciplinary approach that concerns cutting-edge advances on primary radiation events, considering the potentialities of innovating strategies based on ultrafast laser science, from femtosecond photon sources to laser-driven relativistic particles acceleration. Recent advances of powerful TW laser sources (~ 1019 Wcm‑2) and laser-plasma interactions providing ultrashort relativistic particle beams in the energy domain 2.5–150 MeV open exciting opportunities for the development of high-energy radiation femtochemistry (HERF). Early radiation damages being dependent on the survival probability of secondary electrons and radial distribution of short-lived radicals inside ionization clusters, a thorough knowledge of these processes involves the real-time probing of primary events in the temporal range 10‑14–10‑11 s. In the framework of a closed synergy between low-energy radiation femtochemistry (LERF) and the emerging domain of HERF, the paper focuses on early phenomena that occur in the prethermal regime of low-energy secondary electrons, considering very short-lived quantum effects in aqueous environments. A high dose-rate delivered by femtosecond electron beam (~ 1011–1013 Gy s‑1) can be used to investigate early radiation processes in native ionization tracks, down to 10‑12 s and 10‑9 m. We explain how this breakthrough favours the innovating development of real-time nanodosimetry in biologically relevant environments and open new perspectives for spatio-temporal radiation biophysics. The emerging domain of HERF would provide guidance for understanding the specific bioeffects of

  18. Development of an rf driven multicusp ion source for nuclear science experiments

    Science.gov (United States)

    Wutte, D.; Freedman, S.; Gough, R.; Lee, Y.; Leitner, M.; Leung, K. N.; Lyneis, C.; Pickard, D. S.; Williams, M. D.; Xie, Z. Q.

    1998-07-01

    A compact 13.56 MHz radio-frequency (rf) driven multicusp ion source is under development at Lawrence Berkeley National Laboratory (LBNL) for radioactive ion beam applications. In this paper we describe the ion source design and the general ion source performance using H 2, Ar, Xe gas and a 90% Ar/10% CO gas mixture for generating the discharge plasma. The following ion source characteristics have been analyzed: extractable ion current, ion species distributions, ionization efficiency for nobel gases, axial energy spread and ion beam emittance measurements. This ion source can generate ion current densities of approximately 60 mA/cm 2.

  19. High current multicharged metal ion source using high power gyrotron heating of vacuum arc plasma.

    Science.gov (United States)

    Vodopyanov, A V; Golubev, S V; Khizhnyak, V I; Mansfeld, D A; Nikolaev, A G; Oks, E M; Savkin, K P; Vizir, A V; Yushkov, G Yu

    2008-02-01

    A high current, multi charged, metal ion source using electron heating of vacuum arc plasma by high power gyrotron radiation has been developed. The plasma is confined in a simple mirror trap with peak magnetic field in the plug up to 2.5 T, mirror ratio of 3-5, and length variable from 15 to 20 cm. Plasma formed by a cathodic vacuum arc is injected into the trap either (i) axially using a compact vacuum arc plasma gun located on axis outside the mirror trap region or (ii) radially using four plasma guns surrounding the trap at midplane. Microwave heating of the mirror-confined, vacuum arc plasma is accomplished by gyrotron microwave radiation of frequency 75 GHz, power up to 200 kW, and pulse duration up to 150 micros, leading to additional stripping of metal ions by electron impact. Pulsed beams of platinum ions with charge state up to 10+, a mean charge state over 6+, and total (all charge states) beam current of a few hundred milliamperes have been formed.

  20. Limitations of electron cyclotron resonance ion source performances set by kinetic plasma instabilities.

    Science.gov (United States)

    Tarvainen, O; Laulainen, J; Komppula, J; Kronholm, R; Kalvas, T; Koivisto, H; Izotov, I; Mansfeld, D; Skalyga, V

    2015-02-01

    Electron cyclotron resonance ion source (ECRIS) plasmas are prone to kinetic instabilities due to anisotropy of the electron energy distribution function stemming from the resonant nature of the electron heating process. Electron cyclotron plasma instabilities are related to non-linear interaction between plasma waves and energetic electrons resulting to strong microwave emission and a burst of energetic electrons escaping the plasma, and explain the periodic oscillations of the extracted beam currents observed in several laboratories. It is demonstrated with a minimum-B 14 GHz ECRIS operating on helium, oxygen, and argon plasmas that kinetic instabilities restrict the parameter space available for the optimization of high charge state ion currents. The most critical parameter in terms of plasma stability is the strength of the solenoid magnetic field. It is demonstrated that due to the instabilities the optimum Bmin-field in single frequency heating mode is often ≤0.8BECR, which is the value suggested by the semiempirical scaling laws guiding the design of modern ECRISs. It is argued that the effect can be attributed not only to the absolute magnitude of the magnetic field but also to the variation of the average magnetic field gradient on the resonance surface.

  1. Limitations of electron cyclotron resonance ion source performances set by kinetic plasma instabilities

    Energy Technology Data Exchange (ETDEWEB)

    Tarvainen, O., E-mail: olli.tarvainen@jyu.fi; Laulainen, J.; Komppula, J.; Kronholm, R.; Kalvas, T.; Koivisto, H. [Department of Physics, University of Jyväskylä, 40500 Jyväskylä (Finland); Izotov, I.; Mansfeld, D. [Institute of Applied Physics, RAS, 46 Ul‘yanova St., 603950 Nizhny Novgorod (Russian Federation); Skalyga, V. [Institute of Applied Physics, RAS, 46 Ul‘yanova St., 603950 Nizhny Novgorod (Russian Federation); Lobachevsky State University of Nizhny Novgorod (UNN), 23 Gagarina St., 603950 Nizhny Novgorod (Russian Federation)

    2015-02-15

    Electron cyclotron resonance ion source (ECRIS) plasmas are prone to kinetic instabilities due to anisotropy of the electron energy distribution function stemming from the resonant nature of the electron heating process. Electron cyclotron plasma instabilities are related to non-linear interaction between plasma waves and energetic electrons resulting to strong microwave emission and a burst of energetic electrons escaping the plasma, and explain the periodic oscillations of the extracted beam currents observed in several laboratories. It is demonstrated with a minimum-B 14 GHz ECRIS operating on helium, oxygen, and argon plasmas that kinetic instabilities restrict the parameter space available for the optimization of high charge state ion currents. The most critical parameter in terms of plasma stability is the strength of the solenoid magnetic field. It is demonstrated that due to the instabilities the optimum B{sub min}-field in single frequency heating mode is often ≤0.8B{sub ECR}, which is the value suggested by the semiempirical scaling laws guiding the design of modern ECRISs. It is argued that the effect can be attributed not only to the absolute magnitude of the magnetic field but also to the variation of the average magnetic field gradient on the resonance surface.

  2. Comparison of different plasma chambers in microwave ion source for the intense neutron tube

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    The microwave absorption efficiency, which is relevant to magnet field and its distribution, is a major parameter of the microwave ion source (MWIS) for the intense neutron tube. Based on previous work, the relations between microwave absorption efficiency and plasma chamber structure and thickness of the microwave introduction window are studied. The microwave absorption efficiency reaches to 100% when plasma chamber is 100mm long and the window thickness is 30mm. The microwave absorption efficiency as a function of pressure is also presented.

  3. The CPS Plasma Award at the Intel Science and Engineering Fair

    Science.gov (United States)

    Berry, Lee

    2012-10-01

    For the past eight years, the Coalition for Plasma Science (CPS) has presented an award for a plasma project at the Intel International Science and Engineering Fair (ISEF). We reported on the first five years of this award at the 2009 DPP Symposium. Pulsed neutron-producing experiments are a recurring topic, with the efforts now turning to applications. The most recent award at the Pittsburgh ISEF this past May was given for analysis of data from Brookhaven's Relativistic Heavy Ion Collider. The effort had the goal of understanding the fluid properties of the quark-gluon plasma. All of the CPS award-winning projects so far have been based on experiments, with four awards going to women students and four to men. In 2009 we noted that the number and quality of projects was improving. Since then, as we we predicted (hoped for), that trend has continued. The CPS looks forward to continuing its work with students who are excited about the possibilities of plasma. You too can share this excitement by judging at the 2013 fair in Phoenix on May 12-17. Information may be obtained by emailing cps@plasmacoalition.org.

  4. Plagiarism Detection Algorithm for Source Code in Computer Science Education

    Science.gov (United States)

    Liu, Xin; Xu, Chan; Ouyang, Boyu

    2015-01-01

    Nowadays, computer programming is getting more necessary in the course of program design in college education. However, the trick of plagiarizing plus a little modification exists among some students' home works. It's not easy for teachers to judge if there's plagiarizing in source code or not. Traditional detection algorithms cannot fit this…

  5. The influence of lithology on surface water sources | Science ...

    Science.gov (United States)

    Understanding the temporal and spatial variability of surface water sources within a basin is vital to our ability to manage the impacts of climate variability and land cover change. Water stable isotopes can be used as a tool to determine geographic and seasonal sources of water at the basin scale. Previous studies in the Coastal Range of Oregon reported that the variation in the isotopic signatures of surface water does not conform to the commonly observed “rainout effect”, which exhibits a trend of increasing isotopic depletion with rising elevation. The primary purpose of this research is to investigate the mechanisms governing seasonal and spatial variations in the isotopic signature of surface waters within the Marys River Basin, located in the leeward side of the Oregon Coastal Range. Surface water and precipitation samples were collected every 2-3 weeks for isotopic analysis of δ18O and δ2H for one year. Results indicate a significant difference in isotopic signature between watersheds underlain by basalt and sandstone. The degree of separation was the most distinct during the summer when low flows reflect deeper groundwater sources, whereas isotopic signatures during the rainy season (fall and winter) showed a greater degree of similarity between the two lithologies. This indicates that baseflow within streams drained by sandstone versus basalt is being supplied from two distinctly separate water sources. In addition, Marys River flow at the outle

  6. Information sources in science and technology in Finland

    Science.gov (United States)

    Haarala, Arja-Riitta

    1994-01-01

    Finland poses some problems to be overcome in the field of scientific and technical information: a small user community which makes domestic systems costly; great distances within the country between users and suppliers of information; great distances to international data systems and large libraries abroad; and inadequate collections of scientific and technical information. The national bibliography Fennica includes all books and journals published in Finland. Data base services available in Finland include: reference data bases in science and technology; data banks for decision making such as statistical time series or legal proceedings; national bibliographies; and library catalogs.

  7. Electromagnetic radiation from filamentary sources in the presence of axially magnetized cylindrical plasma scatterers

    Energy Technology Data Exchange (ETDEWEB)

    Es’kin, V. A.; Ivoninsky, A. V.; Kudrin, A. V., E-mail: kud@rf.unn.ru; Popova, L. L. [Lobachevsky University (Russian Federation)

    2017-02-15

    Electromagnetic radiation from filamentary electric-dipole and magnetic-current sources of infinite length in the presence of gyrotropic cylindrical scatterers in the surrounding free space is studied. The scatterers are assumed to be infinitely long, axially magnetized circular plasma columns parallel to the axis of the filamentary source. The field and the radiation pattern of each source are calculated in the case where the source frequency is equal to one of the surface plasmon resonance frequencies of the cylindrical scatterers. It is shown that the presence of even a single resonant magnetized plasma scatterer of small electrical radius or a few such scatterers significantly affects the total fields of the filamentary sources, so that their radiation patterns become essentially different from those in the absence of scatterers or the presence of isotropic scatterers of the same shape and size. It is concluded that the radiation characteristics of the considered sources can efficiently be controlled using their resonance interaction with the neighboring gyrotropic scatterers.

  8. Plasma expansion across a transverse magnetic field in a negative hydrogen ion source for fusion

    Science.gov (United States)

    Fantz, U.; Schiesko, L.; Wünderlich, D.

    2014-08-01

    High power negative hydrogen ion sources operating at 0.3 Pa are a key component of the neutral beam injection systems for the international fusion experiment ITER. To achieve the required large ion current at a tolerable number of co-extracted electrons the source is equipped with a magnetic filter field (up to 10 mT). The IPP prototype source (1/8 of the area of the ITER source) has been equipped with a flexible magnetic filter frame to perform filter field studies (position, polarity, strength). Axial profiles of the plasma parameters are measured with two Langmuir probes, positioned in the upper and the lower half of the expansion chamber. In addition to the expected decrease in electron temperature and density a vertical drift develops the direction depending on the polarity of the field. Without field no drift is observed. The drift is less pronounced in caesium seeded discharges and almost vanishes in deuterium, indicating an influence of the ion mass on the drift. A comparison with results from a half-size ITER source reveals that the plasma is much more uniform in the large source.

  9. A numerical simulation of surface wave excitation in a rectangular planar-type plasma source

    Institute of Scientific and Technical Information of China (English)

    Chen Zhao-Quan; Liu Ming-Hai; Lan Chao-Hui; Chen Wei; Tang Liang; Luo Zhi-Qing; Yan Bao-Rong; Lu Jian-Hong; Hu Xi-Wei

    2009-01-01

    The principle of surface wave plasma discharge in a rectangular cavity is introduced simply based on surface plasmon polariton theory.The distribution of surface-wave electric field at the interface of the plasma-dielectric slab is investigated by using the three-dimensional finite-difference time-domain method (3D-FDTD) with different slotantenna structures.And the experimental image of discharge with a novel slot antenna array and the simulation of the electric field with this slot antenna array are both displayed.Combined with the distribution of surface wave excitation and experimental results,the numerical simulation performed by using 3D-FDTD is shown to be a useful tool in the computer-aided antenna design for large area planar-type surface-wave plasma sources.

  10. Unstable plasma characteristics in mirror field electron cyclotron resonance microwave ion source

    Indian Academy of Sciences (India)

    S K Angra; Parshant Kumar; R R Dongaonkar; R P Bajpai

    2000-05-01

    Electron cyclotron plasma reactor are prone to instabilities in specific input power [3–7] region (150–450 watts). In this region power absorption by gas molecules in the cavity is very poor and enhanced input power gets reflected substantially without increasing ion density. There are abrupt changes in plasma characteristics when input power was decreased from maximum to minimum, it was observed that reflected power changed from < 2% to ∼ 50%. Minimum two jumps in reflected power were noticed in this specific power region and these appear to be highly sensitive to three stub tuner position in the waveguide for this particular input power zone. Unstable plasma region of this source is found to be dependent upon the magnetic field strength. Some changes in reflected power are also noticed with pressure, flow and bias and they are random in nature.

  11. Conformal doping of topographic silicon structures using a radial line slot antenna plasma source

    Science.gov (United States)

    Ueda, Hirokazu; Ventzek, Peter L. G.; Oka, Masahiro; Horigome, Masahiro; Kobayashi, Yuuki; Sugimoto, Yasuhiro; Nozawa, Toshihisa; Kawakami, Satoru

    2014-06-01

    Fin extension doping for 10 nm front end of line technology requires ultra-shallow high dose conformal doping. In this paper, we demonstrate a new radial line slot antenna plasma source based doping process that meets these requirements. Critical to reaching true conformality while maintaining fin integrity is that the ion energy be low and controllable, while the dose absorption is self-limited. The saturated dopant later is rendered conformal by concurrent amorphization and dopant containing capping layer deposition followed by stabilization anneal. Dopant segregation assists in driving dopants from the capping layer into the sub silicon surface. Very high resolution transmission electron microscopy-Energy Dispersive X-ray spectroscopy, used to prove true conformality, was achieved. We demonstrate these results using an n-type arsenic based plasma doping process on 10 to 40 nm high aspect ratio fins structures. The results are discussed in terms of the different types of clusters that form during the plasma doping process.

  12. Influence of ion species ratio on grid-enhanced plasma source ion implantation

    Institute of Scientific and Technical Information of China (English)

    Wang Jiu-Li; Zhang Gu-Ling; Liu Yuan-Fu; Wang You-Nian; Liu Chi-Zi; Yang Si-Ze

    2004-01-01

    @@ Grid-enhanced plasma source ion implantation (GEPSII) is a newly proposed technique to modify the inner-surface properties of a cylindrical bore. In this paper, a two-ion fluid model describing nitrogen molecular ions N2+ and atomic ions N+ is used to investigate the ion sheath dynamics between the grid electrode and the inner surface of a cylindrical bore during the GEPSII process, which is an extension of our previous calculations in which only N2+ was considered.Calculations are concentrated on the results of ion dose and impact energy on the target for different ion species ratios in the core plasma. The calculated results show that more atomic ions N+ in the core plasma can raise the ion impact energy and reduce the ion dose on the target.

  13. Middle School Students' Science Self-Efficacy and Its Sources: Examination of Gender Difference

    Science.gov (United States)

    Kiran, Dekant; Sungur, Semra

    2012-01-01

    The main purpose of the present study is to investigate middle school students' science self-efficacy as well as its sources and outcomes as a function of gender. Bandura's hypothesized sources of self-efficacy (i.e., mastery experience, vicarious experience, verbal persuasion, and emotional arousal) in addition to being inviting with self and…

  14. Characterization of a 20 kW helicon source for fusion relevant plasma-surface interactions using microwave and electrostic diagnostics

    Science.gov (United States)

    Caneses, Juan Francisco; Blackwell, Boyd; Guenette, Mathew; Corr, Cormac

    2013-10-01

    The MAGnetized Plasma Interaction Experiment (MAGPIE) is a non-uniform axial magnetic field helicon source built to study fusion relevant plasma-surface interactions. In this work we describe its operation with a new 20 kW pulsed RF source in H2 and He under various discharge configurations. Diagnostics such as RF double probes and a 140 GHz heterodyne Michelson microwave interferometer are used to characterize the performance of the device over a wide range of operational regimes. During initial characterization we have measured plasma densities in excess of 1 × 1019 m-3 in H2 at 12 kW of RF power. Finally, we report on recent work conducted in MAGPIE in close collaboration with the Australian Nuclear Science and Technology Organisation (ANSTO) and the Plasma Research Laboratory (PRL) where biased material samples are subjected to H2 plasma. These samples are then analyzed ex-suti using a variety of material characterization techniques. Materials being investigated include graphite, diamond and tungsten.

  15. Multi-Modality Pulsed AC Source for Medical Applications of Non-Equilibrium Plasmas

    Science.gov (United States)

    Friedrichs, Daniel; Gilbert, James

    2014-10-01

    A burgeoning field has developed around the use of non-equilibrium (``cold'') plasmas for various medical applications, including wound treatment, surface sterilization, non-thermal hemostasis, and selective cell destruction. Proposed devices typically utilize pulsed DC power sources, which have no other therapeutic utility, and may encounter significant regulatory restrictions regarding their safety for use in patient care. Additionally, dedicated capital equipment is difficult for healthcare facilities to justify. In this work, we have demonstrated for the first time the generation of non-equilibrium plasma using pulsed AC output from a specially-designed electrosurgical generator. The ability to power novel non-equilibrium plasma devices from a piece of equipment already ubiquitous in operating theatres should significantly reduce the barriers to adoption of plasma devices. We demonstrate the ability of a prototype device, coupled to this source, to reduce bacterial growth in vitro. Such a system could allow a single surgical instrument to provide both non-thermal sterilization and thermal tissue dissection.

  16. Extreme Ultraviolet Light Emission from Z-Pinch Discharge Plasma Source

    Science.gov (United States)

    Watanabe, Masato; Song, Inho; Sakamoto, Toshiro; Kobayashi, Yasunori; Okino, Akitoshi; Mohanty, Smruti R.; Horioka, Kazuhiko; Hotta, Eiki

    2006-01-01

    A capillary Z-pinch discharge light source for EUV lithography has been developed. Our device is equipped with a water-cooled ceramic capillary and electrodes, and a solid state pulsed power generator. A stacked static induction thyristors are used as switching elements, which enable high repetition rate operation of pulsed power supply. A magnetic switch is connected in series, which not only assists the semiconductor switch but also provides a preionization current. In the present study, EUV radiation emitted from pinching plasma in a xenon-filled capillary was quantitatively measured using an in-band calorimeter. Time-integrated in-band source image was also observed using a pinhole camera system. Furthermore, new electrode system using plasma jet has been developed.

  17. Deposition and sputtering yields on EUV collector mirror from Laser Plasma Extreme Ultraviolet Sources

    Energy Technology Data Exchange (ETDEWEB)

    Wu Tao [Wuhan National Laboratory for Optoelectronics, School of Optoelectronic Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China); Rao Zhiming [Depart of Computer Science, Jiangxi University of Traditional Chinese Medicine, Nanchang 330004, Jiangxi (China); Wang Shifang, E-mail: flatime@163.com [School of Physics and Electric Information, Hubei University of Education 1 Nanhuan Road, Wuhan East High-Tech. Zone, Wuhan 430205, Hubei (China)

    2011-02-01

    Based on the self-similar solution of gas dynamic equations, spherical expansion of the highly ionized plasma with limited mass into a vacuum is investigated for the droplet target laser-produced plasma extreme ultraviolet (LPP-EUV) sources. Using partially numerical and partially analytical technology, the velocity, the temperature and the density profiles in the plume versus ionization degree, adiabatic index and initial conditions are presented. Furthermore, the spatial thickness variations of the deposited substrate witness and ion sputtering yields for Ru, Mo, and Si under Sn ion bombardment are theoretically calculated, which can be useful to enable LPP-EUV sources suppliers to estimate collector lifetime and improve debris mitigation systems.

  18. Inductively driven surface-plasma negative ion source for N-NBI use (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Belchenko, Yu., E-mail: belchenko@inp.nsk.su; Abdrashitov, G.; Deichuli, P.; Ivanov, A.; Gorbovsky, A.; Kondakov, A.; Sanin, A.; Sotnikov, O.; Shikhovtsev, I. [Budker Institute of Nuclear Physics, Siberian Branch of Russian Academy of Sciences, Novosibirsk (Russian Federation)

    2016-02-15

    The long-pulse surface-plasma source prototype is developed at Budker Institute of Nuclear Physics for negative-ion based neutral beam injector use. The essential source features are (1) an active temperature control of the ion-optical system electrodes by circulation of hot thermal fluid through the channels, drilled in the electrode bodies, (2) the concaved transverse magnetic field in the extraction and acceleration gaps, preventing the electrons trapping and avalanching, and (3) the directed cesium deposition via distribution tubes adjacent to the plasma grid periphery. The long term effect of cesium was obtained just with the single cesium deposition. The high voltage strength of ion-optical system electrodes was improved with actively heated electrodes. A stable H{sup −} beam with a current ∼1 A and energy 90 keV was routinely extracted and accelerated.

  19. SiC detectors for radiation sources characterization and fast plasma diagnostic

    Science.gov (United States)

    Cannavò, A.; Torrisi, L.

    2016-09-01

    Semiconductor detectors based on SiC have been investigated to characterize the radiations (photons and particles) emitted from different sources, such as radioactive sources, electron guns, X-ray tubes and laser-generated plasmas. Detectors show high response velocity, low leakage current, high energy gap and high radiation hardness. Their high detection efficiency permits to use the detectors in spectroscopic mode and in time-of-flight (TOF) approach, generally employed to monitor low and high radiation fluxes, respectively. Using the laser start signal, they permit to study the properties of the generated plasma in vacuum by measuring accurately the particle velocity and energy using pulsed lasers at low and high intensities. Possible applications will be reported and discussed.

  20. Modeling and measuring the transport and scattering of energetic debris in an extreme ultraviolet plasma source

    Science.gov (United States)

    Sporre, John R.; Elg, Daniel T.; Kalathiparambil, Kishor K.; Ruzic, David N.

    2016-01-01

    A theoretical model for describing the propagation and scattering of energetic species in an extreme ultraviolet (EUV) light lithography source is presented. An EUV light emitting XTREME XTS 13-35 Z-pinch plasma source is modeled with a focus on the effect of chamber pressure and buffer gas mass on energetic ion and neutral debris transport. The interactions of the energetic debris species, which is generated by the EUV light emitting plasma, with the buffer gas and chamber walls are considered as scattering events in the model, and the trajectories of the individual atomic species involved are traced using a Monte Carlo algorithm. This study aims to establish the means by which debris is transported to the intermediate focus with the intent to verify the various mitigation techniques currently employed to increase EUV lithography efficiency. The modeling is compared with an experimental investigation.

  1. DBD plasma source operated in single-filamentary mode for therapeutic use in dermatology

    Science.gov (United States)

    Rajasekaran, Priyadarshini; Mertmann, Philipp; Bibinov, Nikita; Wandke, Dirk; Viöl, Wolfgang; Awakowicz, Peter

    2009-11-01

    Our dielectric barrier discharge (DBD) plasma source for bio-medical application comprises a copper electrode covered with ceramic. Objects of high capacitance such as the human body can be used as the opposite electrode. In this study, the DBD source is operated in single-filamentary mode using an aluminium spike as the opposite electrode, to imitate the conditions when the discharge is ignited on a raised point, such as hair, during therapeutic use on the human body. The single-filamentary discharge thus obtained is characterized using optical emission spectroscopy, numerical simulation, voltage-current measurements and microphotography. For characterization of the discharge, averaged plasma parameters such as electron distribution function and electron density are determined. Fluxes of nitric oxide (NO), ozone (O3) and photons reaching the treated surface are simulated. The calculated fluxes are finally compared with corresponding fluxes used in different bio-medical applications.

  2. Synchrotron light sources and free-electron lasers accelerator physics, instrumentation and science applications

    CERN Document Server

    Khan, Shaukat; Schneider, Jochen; Hastings, Jerome

    2016-01-01

    Hardly any other discovery of the nineteenth century did have such an impact on science and technology as Wilhelm Conrad Röntgen’s seminal find of the X-rays. X-ray tubes soon made their way as excellent instruments for numerous applications in medicine, biology, materials science and testing, chemistry and public security. Developing new radiation sources with higher brilliance and much extended spectral range resulted in stunning developments like the electron synchrotron and electron storage ring and the freeelectron laser. This handbook highlights these developments in fifty chapters. The reader is given not only an inside view of exciting science areas but also of design concepts for the most advanced light sources. The theory of synchrotron radiation and of the freeelectron laser, design examples and the technology basis are presented. The handbook presents advanced concepts like seeding and harmonic generation, the booming field of Terahertz radiation sources and upcoming brilliant light sources dri...

  3. Chromospheric Nanoflares as a Source of Coronal Plasma: II. Repeating Nanoflares

    CERN Document Server

    Bradshaw, Stephen J

    2016-01-01

    The million degree plasma of the solar corona must be supplied by the underlying layers of the atmosphere. The mechanism and location of energy release, and the precise source of coronal plasma, remain unresolved. In earlier work we pursued the idea that warm plasma is supplied to the corona via direct heating of the chromosphere by nanoflares, contrary to the prevailing belief that the corona is heated in-situ and the chromosphere is subsequently energized and ablated by thermal conduction. We found that single (low-frequency) chromospheric nanoflares could not explain the observed intensities, Doppler-shifts, and red/blue asymmetries in Fe XII and XIV emission lines. In the present work we follow up on another suggestion that the corona could be powered by chromospheric nanoflares that repeat on a timescale substantially shorter than the cooling/draining timescale. That is, a single magnetic strand is re-supplied with coronal plasma before the existing plasma has time to cool and drain. We perform a series ...

  4. The dispersion and matching characteristics of the helical resonator plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Niazi, K.; Lichtenberg, A.J.; Lieberman, M.A. [Univ. of California, Berkeley, CA (United States)

    1995-10-01

    The dispersion characteristics and the fields of a helical resonator are obtained. The coil is approximated by a helical current layer with infinite conductivity along the current direction (a ``sheath helix``). The plasma column is modeled as a cylindrical dielectric in which the dielectric losses can be neglected in determining the propagation properties of the resonator. Assuming the plasma losses are known, the model can be used to study the matching of the helical resonator to an external power source which is connected to the helix by a tap. The resonator is modeled as a parallel connection of two transmission line segments on each side of the tap position. The authors determine the efficiency of power transfer to the resonator as a function of the tap position driving frequency, and plasma loading. They find that whereas for a small plasma loading it is possible to achieve perfect matching, there exists a critical value of plasma loading beyond which a perfect match is no longer possible.

  5. Effect of Wall Material on H– Production in a Plasma Sputter-Type Ion Source

    Directory of Open Access Journals (Sweden)

    Y. D. M. Ponce

    2004-12-01

    Full Text Available The effect of wall material on negative hydrogen ion (H– production was investigated in a multicusp plasma sputter-type ion source (PSTIS. Steady-state cesium-seeded hydrogen plasma was generated by a tungsten filament, while H– was produced through surface production using a molybdenum sputter target. Plasma parameters and H– yields were determined from Langmuir probe and Faraday cup measurements, respectively. At an input hydrogen pressure of 1.2 mTorr and optimum plasma discharge parameters Vd = –90 V and Id = –2.25 A, the plasma parameters ne was highest and T–e was lowest as determined from Langmuir probe measurements. At these conditions, aluminum generates the highest ion current density of 0.01697 mA/cm2, which is 64% more than the 0.01085 mA/cm2 that stainless steel produces. The yield of copper, meanwhile, falls between the two materials at 0.01164 mA/cm2. The beam is maximum at Vt = –125 V. Focusing is achieved at VL = –70 V for stainless steel, Vt = –60 V for aluminum, and Vt = –50 V for copper. The results demonstrate that proper selection of wall material can greatly enhance the H– production of the PSTIS.

  6. Operational and theoretical temperature considerations in a Penning surface plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Faircloth, D. C., E-mail: dan.faircloth@stfc.ac.uk; Lawrie, S. R. [ISIS Neutron and Muon Facility, STFC Rutherford Appleton Laboratory, Harwell Oxford, OX11 0QX (United Kingdom); Pereira Da Costa, H. [CERN, Geneva (Switzerland); Dudnikov, V. [Muons Inc. United States of America (United States)

    2015-04-08

    A fully detailed 3D thermal model of the ISIS Penning surface plasma source is developed in ANSYS. The proportion of discharge power applied to the anode and cathode is varied until the simulation matches the operational temperature observations. The range of possible thermal contact resistances are modelled, which gives an estimation that between 67% and 85% of the discharge power goes to the cathode. Transient models show the electrode surface temperature rise during the discharge pulse for a range of duty cycles. The implications of these measurements are discussed and a mechanism for governing cesium coverage proposed. The requirements for the design of a high current long pulse source are stated.

  7. A study on vacuum aspects of electron cyclotron resonance ion source plasma

    Science.gov (United States)

    Ghosh, S.; Taki, G. S.; Mallick, C.; Bhandari, R. K.

    2008-05-01

    The electron cyclotron resonance (ECR) ion source is special type hot plasma machine where the high temperature electrons co-exist with multiply charge state ions and neutrals. A few years ago 6.4 GHz. ECR ion source (VEC-ECR) was developed indigenously at VECC. This multiply charged ion source is being used continuously to inject heavy ion beams into the cyclotron. Vacuum plays the major role in ECR ion source. The water cooled plasma chamber is made from an oxygen free high conductivity copper billet to meet the suitable surface condition for vacuum purpose. The entire volume of the ion source is pumped by two 900 1/s special type oil diffusion pumps to achieve 5×10-8 Torr. Usually main plasma chamber is pumped by the plasma itself. Moreover a few 1/s additional pumping speed is provided through extraction hole and pumping slot on the extraction electrode. A study has been carried out to understand the role of vacuum on the multiply charged heavy ion production process. Considering the ion production and loss criteria, it is seen that for getting Ar18+ better vacuum is essential for lower frequency operation. So, an ECR ion source can give better charge state current output operating at higher frequency and stronger confining magnetic field under a specific vacuum condition. The low pressure condition is essential to minimize charge exchange loss due to recombination of multiply charged ions with the neutral atoms. A fixed ratio of neutral to electron density must be maintained for optimizing a particular charge state in the steady state condition. As the electron density is proportional to square of the injected microwave frequency (nevpropf2) a particular operating pressure is essential for a specific charge state. From the study, it has been obtained that the production of Ar18+ ions needs a pressure ~ 9.6×10-8 Torr for 6.4 GHz. ECR ion source. It is also obtained that an ECR ion source, works at a particular vacuum level, can give better charge state

  8. Study of interaction of hot core plasma sources and micro-shock waves

    Science.gov (United States)

    Chelikani, Leela; Bagchi, Suman; Paturi, Prem Kiran

    2013-10-01

    Laser Induced Shockwaves (LISWs) have many applications from material processing to therapeutics. In almost all the processes and applications, understanding the conversion of laser energy to kinetic energy propagating as a shockwave (SW) is essential. We present the results on interaction of multiple plasma sources leading to SWs generated using Nd:YAG laser pulses (532 nm, 7 ns) (a) in atmospheric air and (b) from 1-D periodic structured surfaces (PSS) of 30 μm depth and 240 +/- 20 μm diameter having 25 and 64 lpi (lines per inch). Using time resolved shadowgraphy the novel aspects of (1) the presence of two distinct sources of ionization along the laser propagation direction modifying the nature of SWs around the focal plane and (2) the interaction of these two sources leading to the transition of hot core plasma in air analogous to that of a cavitation bubble in fluids are presented. Analogous phenomena of modification SW nature were observed from 1-D PSS. The effect of surface modulation on the SW and Contact Front dynamics was compared from that of a flat surface (FS). The initial studies in two different media indicate the possibility to control the SWs, either accelerate or decelerate by varying the plasma dynamics. Defence Research and Development Organization, India.

  9. Nanocomposite metal/plasma polymer films prepared by means of gas aggregation cluster source

    Energy Technology Data Exchange (ETDEWEB)

    Polonskyi, O.; Solar, P.; Kylian, O.; Drabik, M.; Artemenko, A.; Kousal, J.; Hanus, J.; Pesicka, J.; Matolinova, I. [Charles University in Prague, Faculty of Mathematics and Physics, V Holesovickach 2, 18000 Prague 8 (Czech Republic); Kolibalova, E. [Tescan, Libusina trida 21, 632 00 Brno (Czech Republic); Slavinska, D. [Charles University in Prague, Faculty of Mathematics and Physics, V Holesovickach 2, 18000 Prague 8 (Czech Republic); Biederman, H., E-mail: bieder@kmf.troja.mff.cuni.cz [Charles University in Prague, Faculty of Mathematics and Physics, V Holesovickach 2, 18000 Prague 8 (Czech Republic)

    2012-04-02

    Nanocomposite metal/plasma polymer films have been prepared by simultaneous plasma polymerization using a mixture of Ar/n-hexane and metal cluster beams. A simple compact cluster gas aggregation source is described and characterized with emphasis on the determination of the amount of charged clusters and their size distribution. It is shown that the fraction of neutral, positively and negatively charged nanoclusters leaving the gas aggregation source is largely influenced by used operational conditions. In addition, it is demonstrated that a large portion of Ag clusters is positively charged, especially when higher currents are used for their production. Deposition of nanocomposite Ag/C:H plasma polymer films is described in detail by means of cluster gas aggregation source. Basic characterization of the films is performed using transmission electron microscopy, ultraviolet-visible and Fourier-transform infrared spectroscopies. It is shown that the morphology, structure and optical properties of such prepared nanocomposites differ significantly from the ones fabricated by means of magnetron sputtering of Ag target in Ar/n-hexane mixture.

  10. Negative ion beam formation using thermal contact ionization type plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Fukuura, Yoshiyuki; Murakami, Kazutugu; Masuoka, Toshio; Katsumata, Itsuo [Osaka City Univ. (Japan). Faculty of Engineering

    1997-02-01

    The small ion sources utilizing thermal ionization have been already developed, and at present, in order to increase ion yield, that being developed to the cylindrical plasma prototype having the inner surface of a Re foil cylinder as the ionization surface, and stably functioning at 3,000 K has been developed, and by using this plasma source, the research on the formation of various ions has been carried out. At present, the research on the formation of Li negative ion beam is carried out. The separation of negative ions from electrons is performed with the locally limited magnetic field using a small iron core electromagnet placed behind the electrostatic accelerating lens system. So for, the formation of about 2 {mu}A at maximum of negative ions was confirmed. It was decided to identify the kinds of ions by time of flight (TOF) process, and the various improvements for this purpose were carried out. The experimental setup, the structure of the plasma source, the circuits for TOF measurement and so on are explained. The experimental results are reported. The problems are the possibility of the formation of alkali metals, the resolution of the time axis of the TOF system and so on. (K.I.)

  11. Penning plasma based simultaneous light emission source of visible and VUV lights

    Science.gov (United States)

    Vyas, G. L.; Prakash, R.; Pal, U. N.; Manchanda, R.; Halder, N.

    2016-06-01

    In this paper, a laboratory-based penning plasma discharge source is reported which has been developed in two anode configurations and is able to produce visible and VUV lights simultaneously. The developed source has simultaneous diagnostics facility using Langmuir probe and optical emission spectroscopy. The two anode configurations, namely, double ring and rectangular configurations, have been studied and compared for optimum use of the geometry for efficient light emissions and recording. The plasma is produced using helium gas and admixture of three noble gases including helium, neon, and argon. The source is capable to produce eight spectral lines for pure helium in the VUV range from 20 to 60 nm and total 24 spectral lines covering the wavelength range 20-106 nm for the admixture of gases. The large range of VUV lines is generated from gaseous admixture rather from the sputtered materials. The recorded spectrum shows that the plasma light radiations in both visible and VUV range are larger in double ring configuration than that of the rectangular configurations at the same discharge operating conditions. To clearly understand the difference, the imaging of the discharge using ICCD camera and particle-in-cell simulation using VORPAL have also been carried out. The effect of ion diffusion, metastable collision with the anode wall and the nonlinear effects are correlated to explain the results.

  12. Penning plasma based simultaneous light emission source of visible and VUV lights

    Energy Technology Data Exchange (ETDEWEB)

    Vyas, G. L., E-mail: glvyas27@gmail.com [Manipal University Jaipur (India); Prakash, R.; Pal, U. N. [CSIR-Central Electronics and Engineering Research Institute, Microwave Tubes Division (India); Manchanda, R. [Institute for Plasma Research (India); Halder, N. [Manipal University Jaipur (India)

    2016-06-15

    In this paper, a laboratory-based penning plasma discharge source is reported which has been developed in two anode configurations and is able to produce visible and VUV lights simultaneously. The developed source has simultaneous diagnostics facility using Langmuir probe and optical emission spectroscopy. The two anode configurations, namely, double ring and rectangular configurations, have been studied and compared for optimum use of the geometry for efficient light emissions and recording. The plasma is produced using helium gas and admixture of three noble gases including helium, neon, and argon. The source is capable to produce eight spectral lines for pure helium in the VUV range from 20 to 60 nm and total 24 spectral lines covering the wavelength range 20–106 nm for the admixture of gases. The large range of VUV lines is generated from gaseous admixture rather from the sputtered materials. The recorded spectrum shows that the plasma light radiations in both visible and VUV range are larger in double ring configuration than that of the rectangular configurations at the same discharge operating conditions. To clearly understand the difference, the imaging of the discharge using ICCD camera and particle-in-cell simulation using VORPAL have also been carried out. The effect of ion diffusion, metastable collision with the anode wall and the nonlinear effects are correlated to explain the results.

  13. History of Science in the Physics Curriculum: A Directed Content Analysis of Historical Sources

    Science.gov (United States)

    Seker, Hayati; Guney, Burcu G.

    2012-05-01

    Although history of science is a potential resource for instructional materials, teachers do not have a tendency to use historical materials in their lessons. Studies showed that instructional materials should be adaptable and consistent with curriculum. This study purports to examine the alignment between history of science and the curriculum in the light of the facilitator model on the use of history of science in science teaching, and to expose possible difficulties in preparing historical materials. For this purpose, qualitative content analysis method was employed. Codes and themes were defined beforehand, with respect to levels and their sublevels of the model. The analysis revealed several problems with the alignment of historical sources for the physics curriculum: limited information about scientists' personal lives, the difficulty of linking with content knowledge, the lack of emphasis on scientific process in the physics curriculum, differences between chronology and sequence of topics, the lack of information about scientists' reasoning. Based on the findings of the analysis, it would be difficult to use original historical sources; educators were needed to simplify historical knowledge within a pedagogical perspective. There is a need for historical sources, like Harvard Case Histories in Experimental Science, since appropriate historical information to the curriculum objectives can only be obtained by simplifying complex information at the origin. The curriculum should leave opportunities for educators interested in history of science, even historical sources provides legitimate amount of information for every concepts in the curriculum.

  14. Plasma kinetics, tissue distribution, and cerebrocortical sources of reverse triiodothyronine in the rat

    Energy Technology Data Exchange (ETDEWEB)

    Obregon, M.J.; Larsen, P.R.; Silva, J.E.

    1985-06-01

    Studies in vitro have shown that rT3 is a potent and competitive inhibitor of T4 5'-deiodination (5'D). Recent studies in vivo have shown that cerebrocortical (Cx) T4 5'D-type II (5'D-II) activity (propylthiouracil (PTU) insensitive pathway), is reduced by T4 and rT3, the latter being more potent than T3 in Cx 5'D-II suppression. Some other reports had described rT3 production in rat brain as a very active pathway of thyroid hormone metabolism. To examine the possibility that rT3 plays a physiological role in regulating Cx 5'D-II, we have explored rT3 plasma kinetics, plasma to tissue exchange, and uptake by tissues in the rat, as well as the metabolic routes of degradation and the sources of rT3 in cerebral cortex (Cx). Plasma and tissue levels were assessed with tracer (/sup 125/I)rT3. Two main compartments were defined by plasma disappearance curves in euthyroid rats (K/sub 1/ = -6.2 h-1 and K/sub 2/ = -0.75 h-1). In Cx of euthyroid rats, (/sup 125/I)rT3 peaked 10 min after iv injection, tissue to plasma ratio being 0.016 +/- 0.004 (SE). In thyroidectomized rats, plasma and tissue (/sup 125/I)rT3 concentrations were higher than in euthyroid rats, except for the Cx that did not change. PTU caused further increases in all the tissues studied, except for the Cx and the pituitaries of thyroidectomized rats. From the effect of blocking 5'D-I with PTU or reducing its activity by making the animals hypothyroid, we concluded that 5'D-I accounts for most of the rT3 clearance from plasma. In contrast, in Cx and pituitary the levels of rT3 seem largely affected by 5'D-II activity. Since the latter results suggest that plasma rT3 does not play a major role in determining rT3 levels in these tissues, we explored the sources of rT3 in Cx using (/sup 125/I)T4. The (/sup 125/I)rT3 (T4) to (/sup 125/I)T4 ratio remained constant at 0.03 from 1 up to 5 h after injection of (/sup 125/I)T4.

  15. What are the Sources of Solar Energetic Particles? Element Abundances and Source Plasma Temperatures

    CERN Document Server

    Reames, Donald V

    2015-01-01

    We have spent 50 years in heated discussion over which populations of solar energetic particles (SEPs) are accelerated at flares and which by shock waves driven out from the Sun by coronal mass ejections (CMEs). The association of the large "gradual" SEP events with shock acceleration is supported by the extensive spatial distribution of SEPs and by the delayed acceleration of the particles. The relative abundances of the elements in these gradual events are a measure of those in the ambient solar corona, differing from those in the photosphere by a widely-observed function of the first ionization potential (FIP) of the elements. SEP events we call "impulsive", the traditional "3He-rich" events with enhanced heavy-element abundances, are associated with type III radio bursts, flares, and narrow CMEs; they selectively populate flux tubes that thread a localized source, and they are fit to new particle-in-cell models of magnetic reconnection on open field lines as found in solar jets. These models help explain ...

  16. CERN LINAC4 H- Source and SPL plasma generator RF systems, RF power coupling and impedance measurements

    CERN Document Server

    Paoluzzi, M; Marques-Balula, J; Nisbet, D

    2010-01-01

    In the LINAC4 H- source and the SPL plasma generator at CERN, the plasma is heated by a 100 kW, 2 MHz RF system. Matching of the load impedance to the final amplifier is achieved with a resonant network. The system implements a servo loop for power stabilization and frequency hopping to cope with the detuning effects induced by the plasma. This paper provides a detailed description of the system, including the pulse rate increase to 50 Hz for use in the SPL plasma generator. The performances, measurements of RF power coupling, contribution of the plasma to the impedance as well as first operation are reported.

  17. Laser-driven electron beamlines generated by coupling laser-plasma sources with conventional transport systems

    Energy Technology Data Exchange (ETDEWEB)

    Antici, P. [Istituto Nazionale di Fisica Nucleare (INFN), Laboratori Nazionali di Frascati, Via E. Fermi, 40, 00044 Frascati (Italy); SAPIENZA, University of Rome, Dip. SBAI, Via A. Scarpa 14, 00161 Rome (Italy); INFN - Sezione di Roma, c/o Dipartimento di Fisica - SAPIENZA, University of Rome, P.le Aldo Moro, 2 - 00185 Rome (Italy); Bacci, A.; Chiadroni, E.; Ferrario, M.; Rossi, A. R. [Istituto Nazionale di Fisica Nucleare (INFN), Laboratori Nazionali di Frascati, Via E. Fermi, 40, 00044 Frascati (Italy); Benedetti, C. [University of Bologna and INFN - Bologna (Italy); Lancia, L.; Migliorati, M.; Mostacci, A.; Palumbo, L. [SAPIENZA, University of Rome, Dip. SBAI, Via A. Scarpa 14, 00161 Rome (Italy); INFN - Sezione di Roma, c/o Dipartimento di Fisica - SAPIENZA, University of Rome, P.le Aldo Moro, 2 - 00185 Rome (Italy); Serafini, L. [INFN-Milan and Department of Physics, University of Milan, Via Celoria 16, 20133 Milan (Italy)

    2012-08-15

    Laser-driven electron beamlines are receiving increasing interest from the particle accelerator community. In particular, the high initial energy, low emittance, and high beam current of the plasma based electron source potentially allow generating much more compact and bright particle accelerators than what conventional accelerator technology can achieve. Using laser-generated particles as injectors for generating beamlines could significantly reduce the size and cost of accelerator facilities. Unfortunately, several features of laser-based particle beams need still to be improved before considering them for particle beamlines and thus enable the use of plasma-driven accelerators for the multiple applications of traditional accelerators. Besides working on the plasma source itself, a promising approach to shape the laser-generated beams is coupling them with conventional accelerator elements in order to benefit from both a versatile electron source and a controllable beam. In this paper, we perform start-to-end simulations to generate laser-driven beamlines using conventional accelerator codes and methodologies. Starting with laser-generated electrons that can be obtained with established multi-hundred TW laser systems, we compare different options to capture and transport the beams. This is performed with the aim of providing beamlines suitable for potential applications, such as free electron lasers. In our approach, we have analyzed which parameters are critical at the source and from there evaluated different ways to overcome these issues using conventional accelerator elements and methods. We show that electron driven beamlines are potentially feasible, but exploiting their full potential requires extensive improvement of the source parameters or innovative technological devices for their transport and capture.

  18. Laser-driven electron beamlines generated by coupling laser-plasma sources with conventional transport systems

    Science.gov (United States)

    Antici, P.; Bacci, A.; Benedetti, C.; Chiadroni, E.; Ferrario, M.; Rossi, A. R.; Lancia, L.; Migliorati, M.; Mostacci, A.; Palumbo, L.; Serafini, L.

    2012-08-01

    Laser-driven electron beamlines are receiving increasing interest from the particle accelerator community. In particular, the high initial energy, low emittance, and high beam current of the plasma based electron source potentially allow generating much more compact and bright particle accelerators than what conventional accelerator technology can achieve. Using laser-generated particles as injectors for generating beamlines could significantly reduce the size and cost of accelerator facilities. Unfortunately, several features of laser-based particle beams need still to be improved before considering them for particle beamlines and thus enable the use of plasma-driven accelerators for the multiple applications of traditional accelerators. Besides working on the plasma source itself, a promising approach to shape the laser-generated beams is coupling them with conventional accelerator elements in order to benefit from both a versatile electron source and a controllable beam. In this paper, we perform start-to-end simulations to generate laser-driven beamlines using conventional accelerator codes and methodologies. Starting with laser-generated electrons that can be obtained with established multi-hundred TW laser systems, we compare different options to capture and transport the beams. This is performed with the aim of providing beamlines suitable for potential applications, such as free electron lasers. In our approach, we have analyzed which parameters are critical at the source and from there evaluated different ways to overcome these issues using conventional accelerator elements and methods. We show that electron driven beamlines are potentially feasible, but exploiting their full potential requires extensive improvement of the source parameters or innovative technological devices for their transport and capture.

  19. A Proposal for a Novel H- Ion Source Based on Electron Cyclotron Resonance Plasma Heating and Surface Ionization

    Science.gov (United States)

    Tarvainen, O.; Kurennoy, S.

    2009-03-01

    A design for a novel H- ion source based on electron cyclotron resonance plasma heating and surface ionization is presented. The plasma chamber of the source is an rf-cavity designed for TE111 eigenmode at 2.45 GHz. The desired mode is excited with a loop antenna. The ionization process takes place on a cesiated surface of a biased converter electrode. The H- ion beam is further "self-extracted" through the plasma region. The magnetic field of the source is optimized for plasma generation by electron cyclotron resonance heating, and beam extraction. The design features of the source are discussed in detail and the attainable H- ion current, beam emittance and duty factor of the novel source are estimated.

  20. Report of the Basic Energy Sciences Workshop on Compact Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Barletta, William A. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Borland, Michael [Argonne National Lab. (ANL), Argonne, IL (United States)

    2010-05-11

    This report is based on a BES Workshop on Compact Light Sources, held May 11-12, 2010, to evaluated the advantages and disadvantages of compact light source approaches and compared their performance to the third generation storage rings and free-electron lasers. The workshop examined the state of the technology for compact light sources and their expected progress. The workshop evaluated the cost efficiency, user access, availability, and reliability of such sources. Working groups evaluated the advantages and disadvantages of Compact Light Source (CLS) approaches, and compared their performance to the third-generation storage rings and free-electron lasers (FELs). The primary aspects of comparison were 1) cost effectiveness, 2) technical availability v. time frame, and 3) machine reliability and availability for user access. Five categories of potential sources were analyzed: 1) inverse Compton scattering (ICS) sources, 2) mini storage rings, 3) plasma sources, 4) sources using plasma-based accelerators, and 5) laser high harmonic generation (HHG) sources. Compact light sources are not a substitute for large synchrotron and FEL light sources that typically also incorporate extensive user support facilities. Rather they offer attractive, complementary capabilities at a small fraction of the cost and size of large national user facilities. In the far term they may offer the potential for a new paradigm of future national user facility. In the course of the workshop, we identified overarching R&D topics over the next five years that would enhance the performance potential of both compact and large-scale sources: Development of infrared (IR) laser systems delivering kW-class average power with femtosecond pulses at kHz repetition rates. These have application to ICS sources, plasma sources, and HHG sources. Development of laser storage cavities for storage of 10-mJ picosecond and femtosecond pulses focused to micron beam sizes. Development of high-brightness, high

  1. Debris-free laser plasma sources for EUVL based on gas jets

    Energy Technology Data Exchange (ETDEWEB)

    Kubiak, G.D.; O`Connell, D.; Krenz, K.D.

    1996-03-01

    EUV sources for EUVL must not only be bright for throughput, they must also be debris-free to increase condenser longevity. Many schemes to achieve bright, clean sources for EUVL have been studied, including mass-limited targets, cryogenic targets, electric discharges, and electron-beam pumped vapor. Several of these sources show promise, with varying degrees of brightness, debris reduction, and system complexity. We have studied pulsed gas jets, which we find to be relatively simple, debris-free sources when used under appropriate conditions. Under transverse, 1.06 {mu}m irradiation of the jet at incident laser intensities in the range of 10{sup 11}-10{sup 12} Watts/cm{sup 2}, the conversion efficiency into 2{pi} steradians is in the range of 0.3-0.4%, or approximately half the value exhibited by solid Au or W targets under similar conditions. Source sizes in the range of 350 {mu}m x 400 {mu}m can be achieved, as shown in Fig. 2, depending sensitively on both laser and gas jet parameters. One issue that must be overcome in the use of gas jet targets is the requirement that the laser-irradiated plasma be located as far from the jet nozzle as possible to avoid debris generation while maintaining adequate EUV conversion. We will describe conditions under which these criteria are met. Measurements of the reflectance lifetimes of multilayer-coated mirrors placed near the plasma source under these conditions will also be presented. The potential for scaling such sources up to meet the requirements of a commercial EUVL system will be discussed.

  2. Experimental investigation of laser-produced-plasma EUV source based on liquid target

    Institute of Scientific and Technical Information of China (English)

    QI Li-hong; NI Qi-liang; CHEN Bo

    2005-01-01

    A laser-produced plasma(LPP) source was built using liquid as target and a Nd:YAG laser as the irradiation laser, and the LPP source's radiation with ethanol and acetone target respectively was measured by an AXUV100 silicon photodiode combined with a McPHERSON model 247 grazing incidence monochromator of the resolution Δλ≤0.075 nm and the wavelength scanning interval 0.5 nm. Both ethanol and acetone target LPP source had EUV emission at 11~20 nm wavelength. The comparison between the spectra of the two kinds of target materials shows that all the two kinds of target source's spectra are the result of oxygen ions' transitions under current source's parameters, but the spectrum intensity from different target sources is different. The spectra intensity from the ethanol target is higher than that from the acetone target. In addition, the target liquid is forced into the vacuum chamber by the background pressure supported by the connected external high pressure gas, and the influence of the background pressure on the source's intensity is investigated.

  3. How Source Information Shapes Lay Interpretations of Science Conflicts: Interplay between Sourcing, Conflict Explanation, Source Evaluation, and Claim Evaluation

    Science.gov (United States)

    Thomm, Eva; Bromme, Rainer

    2016-01-01

    When laypeople read controversial scientific information in order to make a personally relevant decision, information on the source is a valuable resource with which to evaluate multiple, competing claims. Due to their bounded understanding, laypeople rely on the expertise of others and need to identify whether sources are credible. The present…

  4. How Source Information Shapes Lay Interpretations of Science Conflicts: Interplay between Sourcing, Conflict Explanation, Source Evaluation, and Claim Evaluation

    Science.gov (United States)

    Thomm, Eva; Bromme, Rainer

    2016-01-01

    When laypeople read controversial scientific information in order to make a personally relevant decision, information on the source is a valuable resource with which to evaluate multiple, competing claims. Due to their bounded understanding, laypeople rely on the expertise of others and need to identify whether sources are credible. The present…

  5. Isotope ratio mass spectrometry as a tool for source inference in forensic science: A critical review.

    Science.gov (United States)

    Gentile, Natacha; Siegwolf, Rolf T W; Esseiva, Pierre; Doyle, Sean; Zollinger, Kurt; Delémont, Olivier

    2015-06-01

    Isotope ratio mass spectrometry (IRMS) has been used in numerous fields of forensic science in a source inference perspective. This review compiles the studies published on the application of isotope ratio mass spectrometry (IRMS) to the traditional fields of forensic science so far. It completes the review of Benson et al. [1] and synthesises the extent of knowledge already gathered in the following fields: illicit drugs, flammable liquids, human provenancing, microtraces, explosives and other specific materials (packaging tapes, safety matches, plastics, etc.). For each field, a discussion assesses the state of science and highlights the relevance of the information in a forensic context. Through the different discussions which mark out the review, the potential and limitations of IRMS, as well as the needs and challenges of future studies are emphasized. The paper elicits the various dimensions of the source which can be obtained from the isotope information and demonstrates the transversal nature of IRMS as a tool for source inference.

  6. Near Real Time Tools for ISS Plasma Science and Engineering Applications

    Science.gov (United States)

    Minow, Joseph I.; Willis, Emily M.; Parker, Linda Neergaard; Shim, Ja Soon; Kuznetsova, Maria M.; Pulkkinen, Antti, A.

    2013-01-01

    The International Space Station (ISS) program utilizes a plasma environment forecast for estimating electrical charging hazards for crews during extravehicular activity (EVA). The process uses ionospheric electron density (Ne) and temperature (Te) measurements from the ISS Floating Potential Measurement Unit (FPMU) instrument suite with the assumption that the plasma conditions will remain constant for one to fourteen days with a low probability for a space weather event which would significantly change the environment before an EVA. FPMU data is typically not available during EVA's, therefore, the most recent FPMU data available for characterizing the state of the ionosphere during EVA is typically a day or two before the start of an EVA or after the EVA has been completed. Three near real time space weather tools under development for ISS applications are described here including: (a) Ne from ground based ionosonde measurements of foF2 (b) Ne from near real time satellite radio occultation measurements of electron density profiles (c) Ne, Te from a physics based ionosphere model These applications are used to characterize the ISS space plasma environment during EVA periods when FPMU data is not available, monitor for large changes in ionosphere density that could render the ionosphere forecast and plasma hazard assessment invalid, and validate the "persistence of conditions" forecast assumption. In addition, the tools are useful for providing space environment input to science payloads on ISS and anomaly investigations during periods the FPMU is not operating.

  7. Fast plasma discharge capillary design as a high power throughput soft x-ray emission source.

    Science.gov (United States)

    Wyndham, E S; Favre, M; Valdivia, M P; Valenzuela, J C; Chuaqui, H; Bhuyan, H

    2010-09-01

    We present the experimental details and results from a low energy but high repetition rate compact plasma capillary source for extreme ultraviolet and soft x-ray research and applications. Two lengths of capillary are mounted in two versions of a closely related design. The discharge operates in 1.6 and 3.2 mm inner diameter alumina capillaries of lengths 21 and 36 mm. The use of water both as dielectric and as coolant simplifies the compact low inductance design with nanosecond discharge periods. The stored electrical energy of the discharge is approximately 0.5 J and is provided by directly charging the capacitor plates from an inexpensive insulated-gate bipolar transistor in 1 μs or less. We present characteristic argon spectra from plasma between 30 and 300 Å as well as temporally resolved x-ray energy fluence in discrete bands on axis. The spectra also allow the level of ablated wall material to be gauged and associated with useful capillary lifetime according to the chosen configuration and energy storage. The connection between the electron beams associated with the transient hollow cathode mechanism, soft x-ray output, capillary geometry, and capillary lifetime is reported. The role of these e-beams and the plasma as measured on-axis is discussed. The relation of the electron temperature and the ionization stages observed is discussed in the context of some model results of ionization in a non-Maxwellian plasma.

  8. Modeling laser produced plasmas with smoothed particle hydrodynamics for next generation advanced light sources

    Science.gov (United States)

    Holladay, Robert; Griffith, Alec; Murillo, Michael S.

    2016-10-01

    A computational model has been developed to study the evolution of a plasma generated by next-generation advanced light sources such as SLAC's LCLS and LANL's proposed MaRIE. Smoothed Particle Hydrodynamics (SPH) is used to model the plasma evolution because of the ease with which it handles the open boundary conditions and large deformations associated with these experiments. Our work extends the basic SPH method by utilizing a two-fluid model of an electron-ion plasma that also incorporates time dependent ionization and recombination by allowing the SPH fluid particles to have an evolving mass based on the mean ionization state of the plasma. Additionally, inter-species heating, thermal conduction, and electric fields are also accounted for. The effects of various initial conditions and model parameters will be presented, with the goal of using this framework to develop a model that can be used in the design and interpretation of future experiments. This work was supported by the Los Alamos National Laboratory Computational Physics Workshop.

  9. Numerical simulation of the RF plasma discharge in the Linac4 H- ion source

    Science.gov (United States)

    Mattei, S.; Nishida, K.; Onai, M.; Lettry, J.; Tran, M. Q.; Hatayama, A.

    2017-08-01

    This paper presents a Particle-In-Cell Monte Carlo Collision simulation of the Radio-Frequency (RF) plasma heating in the Linac4 H- ion source at CERN. The model self-consistently takes into account the electromagnetic field generated by the RF coil, the external static magnetic fields and the resulting plasma response, including a kinetic description of the charged species (e-, H+, H2-, H3+, H-), as well as the atomic and molecular (vibrationally resolved) populations. The simulation is performed for the nominal operational condition of 40 kW RF power and 3 Pa H2 pressure. Results show that the plasma spatial distribution is non-uniform in the plasma chamber, with a density peak of ne = 5 . 1019 m-3 in the RF coil region. In the filter field region the electron density drops by two orders of magnitude, with a substantial reduction of the electron energy as well. This results in a ratio e/H- ≈ 1 in the extraction region. The vibrational population is characterized by a two temperature distribution, with the high vibrational states showing a factor 2 higher termperature. A very good agreement is found between the simulation results and optical emission spectroscopy measurement performed on a dedicated test stand at CERN.

  10. The Project PLASMONX for Plasma Acceleration Experiments and a Thomson X-Ray Source at SPARC

    CERN Document Server

    Serafini, Luca; Alessandria, Franco; Bacci, Alberto; Baldeschi, Walter; Barbini, Alessandro; Bellaveglia, Marco; Bertolucci, Sergio; Biagini, Maria; Boni, Roberto; Bonifacio, Rodolfo; Boscolo, Ilario; Boscolo, Manuela; Bottigli, Ubaldo; Broggi, Francesco; Castellano, Michele; Cecchetti, Carlo A; Cialdi, Simone; Clozza, Alberto; De Martinis, Carlo; Di Pirro, Giampiero; Drago, Alessandro; Esposito, Adolfo; Ferrario, Massimo; Ficcadenti, L; Filippetto, Daniele; Fusco, Valeria; Galimberti, Marco; Gallo, Alessandro; Gatti, Giancarlo; Ghigo, Andrea; Giove, Dario; Giulietti, Antonio; Giulietti, Danilo; Gizzi, Leonida A; Golosio, Bruno; Guiducci, Susanna; Incurvati, Maurizio; Köster, Petra; Labate, Luca; Ligi, Carlo; Marcellini, Fabio; Maroli, Cesare; Mauri, Marco; Migliorati, Mauro; Mostacci, Andrea; Oliva, Pier N; Palumbo, Luigi; Pellegrino, Luigi; Petrillo, Vittoria; Piovella, Nicola; Poggiu, Angela; Pozzoli, Roberto; Preger, Miro; Ricci, Ruggero; Rome, Massimiliano; Rossi, Antonella; Sanelli, Claudio; Serio, Mario; Sgamma, Francesco; Spataro, Bruno; Stecchi, Alessandro; Stella, Angelo; Stumbo, Simone; Tazzioli, Franco; Tommasini, Paolo; Vaccarezza, Cristina; Vescovi, Mario; Vicario, Carlo

    2005-01-01

    We present the status of the activity on the project PLASMONX, which foresees the installation of a multi-TW Ti:Sa laser system at the CNR-ILIL laboratory to conduct plasma acceleration experiments and the construction of an additional beam line at SPARC to develop a Thomson X-ray source at INFN-LNF. After pursuing self-injection experiments at ILIL, when the electron beam at SPARC will be available the SPARC laser system will be upgraded to TW power level in order to conduct either external injection plasma acceleration experiments and ultra-bright X-ray pulse generation with the Thomson source. Results of numerical simulations modeling the interaction of the SPARC electron beam and the counter-propagating laser beam are presented with detailed discussion of the monochromatic X-ray beam spectra generated by Compton backscattering: X-ray energies are tunable in the range 20 to 1000 keV, with pulse duration from 30 fs to 20 ps. Preliminary simulations of plasma acceleration with self-injection are illustrated,...

  11. AmBe Radiological Source Replacement Using Dense Plasma Focus Z-Pinch

    Science.gov (United States)

    Shaw, Brian; Povilus, Alexander; Chapman, Steven; Podpaly, Yuri; Cooper, Christopher; Higginson, Drew; Link, Anthony; Schmidt, Andrea

    2016-10-01

    A dense plasma focus (DPF) is a compact plasma gun that produces high energy ion beams up to several MeV through strong potential gradients formed from m=0 plasma instabilities. These ion beams can be used to replace radiological sources for a variety of applications. Americium-beryllium (AmBe) neutron sources are commonly used for oil well logging. An optimized DPF produces high energy helium ion beams of 2+ MeV which can interact with a beryllium target to produce neutrons. The alpha-Be interaction produces a neutron energy spectrum similar to the neutrons produced by the AmBe reaction. To demonstrate this concept experimentally a 2 kJ DPF is used to produce a beam of alpha particles which interacts with a beryllium target. We report on the improvements made to the DPF platform using He gas and the observation of 3.0 ×104 peak neutrons generated per shot. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  12. Diamondlike carbon deposition on plastic films by plasma source ion implantation

    CERN Document Server

    Tanaka, T; Shinohara, M; Takagi, T

    2002-01-01

    Application of pulsed high negative voltage (approx 10 mu s pulse width, 300-900 pulses per second) to a substrate is found to induce discharge, thereby increasing ion current with an inductively coupled plasma source. This plasma source ion beam implantation (PSII) technique is investigated for the pretreatment and deposition of diamond-like carbon (DLC) thin layer on polyethylene terepthalate (PET) film. Pretreatment of PET with N sub 2 and Ar plasma is expected to provide added barrier effects when coupled with DLC deposition, with possible application to fabrication of PET beverage bottles. PSII treatment using N sub 2 and Ar in separate stages is found to change the color of the PET film, effectively increasing near-ultraviolet absorption. The effects of this pretreatment on the chemical bonding of C, H, and O are examined by x-ray photoelectron spectroscopy (XPS). DLC thin film was successfully deposited on the PET film. The surface of the DLC thin layer is observed to be smooth by scanning electron mic...

  13. Matching a (sub)nanosecond pulse source to a corona plasma reactor

    Science.gov (United States)

    Huiskamp, T.; Beckers, F. J. C. M.; Hoeben, W. F. L. M.; van Heesch, E. J. M.; Pemen, A. J. M.

    2016-10-01

    In this paper we investigate the energy transfer from the pulses of a (sub)nanosecond pulse source to the plasma in a corona-plasma reactor. This energy transfer (or ‘matching’) should be as high as possible. We studied the effect of multiple parameters on matching, such as the reactor configuration, the pulse duration and amplitude and the energy density. The pulse reflection on the reactor interface has a significant influence on matching, and should be as low as possible to transfer the most energy into the reactor. We developed a multiple-wire inner conductor for the reactor which decreases the vacuum impedance of the reactor to decrease the pulse reflection on the reactor interface while maintaining a high electric field on the wire. The results were very encouraging and showed an energy transfer efficiency of over 90 percent. The matching results further show that there is only a small effect on the matching between different wire diameters. In addition, a long reactor and a long pulse result in the best matching due to the more intense plasma that is generated in these conditions. Finally, even without the multiple-wire reactor, we are able to achieve a very good matching (over 80 percent) between our pulse source and the reactor.

  14. Développement d'une source EUV plasma laser pour la micro-lithographie

    Science.gov (United States)

    Segers, M.; Bougeard, M.; Caprin, E.; Ceccotti, T.; Chichmanian, F.; Descamps, D.; Haltebourg, P.; Hergott, J.-F.; Hulin, S.; Normand, D.; Schmidt, M.; Sublemontier, O.

    2003-06-01

    Le Groupe des Applications Plasma (GAP) du CEA à Saclay participe au projet national PREUVE du Réseau Micro- et Nano-Technologies. Ce projet a été lancé fin 1999 pour réunir et développer les compétences en France sur la lithographie dans l'extrême ultraviolet (LEUV). Au sein de PREUVE, notre objectif a été le développement d'une source plasma laser dans I'EUV autour de 13nm afin de contribuer à la réalisation d'un premier banc d'essai pour la lithographie (BEL) en Europe. Afin de réaliser cette source, nous utilisons un plasma émetteur qui est produit par l'interaction d'un laser de type Nd :YAG sur un jet de gouttelettes de xénon. A la fin du projet PREUVE, cette source satisfait les principales spécifications et répond en particulier aux besoins en flux de photons EUV pour réaliser des tests d'insolation EUV avec le banc d'essai. Suite à ces résultats prometteurs, nous démarrons actuellement un projet industriel EXULITE avec nos partenaires du CEA, d'Alcatel et de Thalès sur le développement d'une source EUV de puissance pour des machines de lithographie de production. Ce projet se terminera en 2005.

  15. Development of liquid-jet laser-produced plasma light source for EUV lithography

    Science.gov (United States)

    Abe, Tamotsu; Suganuma, Takashi; Imai, Yousuke; Sugimoto, Yukihiko; Someya, Hiroshi; Hoshino, Hideo; Soumagne, Georg; Komori, Hiroshi; Mizoguchi, Hakaru; Endo, Akira; Toyoda, Koichi

    2003-06-01

    The Extreme UV Lithography System Development Association (EUVA) was established in Japan in May 2002 and is supported by the Ministry of Economy, Trade and Industry (METI). EUVA started the light soruce development in September 2002. This development is done by the assocaition members Gigaphoton, Ushio, Komatsu, Canon, Nikon, the National Institute of Advanced Industrial Sciecne and Technology (AIST) and several Japanese universities. The target of the four-year project is the development of a EUV light source with 10W clean focus point power. For the end of the fiscal year 2003 the development of a 4W EUV light source (clean focus point power) is planned. Both, Laser-Produced-Plasma (LPP) and Discharge-Produced-Plasma (DPP) EUV light sources are investigated at first. Our group at the EUVA Hiratsuka R&D Center is working on LPP sources. We are currently focusing on the development of a driver laser and a liquid Xenon plasma target. The laser is a Nd:YAG MOPA (Master Oscillator and Power Amplifier) system oscillating at 1064 nm. Average power, repetition rate and pulse duration of the laser system are 500 Watt, 10 kHa and 30nsec, respectively. The Xenon liquefication system operates at a maximum pressure of 5MPa and a temperature range between 160 K and 190 K. The pressure inside the vacuum chamber is below 0.1Pa during system operation. This paper presents the current status of the EUV system component development as well as first experimental results of generated EUV radiation.

  16. Laser plasma x-ray source for ultrafast time-resolved x-ray absorption spectroscopy.

    Science.gov (United States)

    Miaja-Avila, L; O'Neil, G C; Uhlig, J; Cromer, C L; Dowell, M L; Jimenez, R; Hoover, A S; Silverman, K L; Ullom, J N

    2015-03-01

    We describe a laser-driven x-ray plasma source designed for ultrafast x-ray absorption spectroscopy. The source is comprised of a 1 kHz, 20 W, femtosecond pulsed infrared laser and a water target. We present the x-ray spectra as a function of laser energy and pulse duration. Additionally, we investigate the plasma temperature and photon flux as we vary the laser energy. We obtain a 75 μm FWHM x-ray spot size, containing ∼10(6) photons/s, by focusing the produced x-rays with a polycapillary optic. Since the acquisition of x-ray absorption spectra requires the averaging of measurements from >10(7) laser pulses, we also present data on the source stability, including single pulse measurements of the x-ray yield and the x-ray spectral shape. In single pulse measurements, the x-ray flux has a measured standard deviation of 8%, where the laser pointing is the main cause of variability. Further, we show that the variability in x-ray spectral shape from single pulses is low, thus justifying the combining of x-rays obtained from different laser pulses into a single spectrum. Finally, we show a static x-ray absorption spectrum of a ferrioxalate solution as detected by a microcalorimeter array. Altogether, our results demonstrate that this water-jet based plasma source is a suitable candidate for laboratory-based time-resolved x-ray absorption spectroscopy experiments.

  17. Laser plasma x-ray source for ultrafast time-resolved x-ray absorption spectroscopy

    Directory of Open Access Journals (Sweden)

    L. Miaja-Avila

    2015-03-01

    Full Text Available We describe a laser-driven x-ray plasma source designed for ultrafast x-ray absorption spectroscopy. The source is comprised of a 1 kHz, 20 W, femtosecond pulsed infrared laser and a water target. We present the x-ray spectra as a function of laser energy and pulse duration. Additionally, we investigate the plasma temperature and photon flux as we vary the laser energy. We obtain a 75 μm FWHM x-ray spot size, containing ∼106 photons/s, by focusing the produced x-rays with a polycapillary optic. Since the acquisition of x-ray absorption spectra requires the averaging of measurements from >107 laser pulses, we also present data on the source stability, including single pulse measurements of the x-ray yield and the x-ray spectral shape. In single pulse measurements, the x-ray flux has a measured standard deviation of 8%, where the laser pointing is the main cause of variability. Further, we show that the variability in x-ray spectral shape from single pulses is low, thus justifying the combining of x-rays obtained from different laser pulses into a single spectrum. Finally, we show a static x-ray absorption spectrum of a ferrioxalate solution as detected by a microcalorimeter array. Altogether, our results demonstrate that this water-jet based plasma source is a suitable candidate for laboratory-based time-resolved x-ray absorption spectroscopy experiments.

  18. IMPEx - a web-based distributed research environment for planetary plasma science

    Science.gov (United States)

    Topf, Florian; Khodachenko, Maxim; Kallio, Esa; Génot, Vincent; Al-Ubaidi, Tarek; Modolo, Ronan; Hess, Sébastien; Schmidt, Walter; Scherf, Manuel; Alexeev, Igor; Gangloff, Michel; Budnik, Elena; Bouchemit, Myriam; Renard, Benjamin; Bourrel, Natacha; Penou, Emmanuel; André, Nicolas; Belenkaya, Elena

    2014-05-01

    The FP7-SPACE project IMPEx (http://impex-fp7.oeaw.ac.at/) was established to provide a web-based infrastructure to facilitate the inter-comparison of spacecraft in-situ measurements and computational models in the fields of planetary plasma science. Within this project several observational (CDAWeb, AMDA, CLWeb), as well as numerical simulation (FMI, LATMOS, SINP) databases provide datasets, which can be combined for further joint analysis and scientific investigation. The major goal of this project consists in providing an environment for the connection and joint operation of the different types of numerical and observational data sources in order to validate numerical simulations with spacecraft observations and vice versa. As an important milestone of IMPEx a common metadata standard was developed for the description of the currently integrated simulation models and the archived datasets. This standard is based on the SPASE data model (DM), which originates from the Heliospheric physics community. This DM was developed for the description of observational data, and that is why it was chosen as a basis within the scope of IMPEx. A considerable part of the project effort is dedicated to the development of standardized (web service-) interfaces and protocols using the SPASE DM as an elaborated IMPEx DM for the communication between the different tools and databases of the IMPEx research infrastructure. For the visualization and analysis of the archived datasets available within IMPEx and beyond, several tools (AMDA, 3DView, ClWeb) were upgraded to be able to work with the newly developed metadata standards and protocols. A practical example will be presented to demonstrate the capabilities and potentials of the achievements of IMPEx by using these tools. Furthermore the IMPEx DM has by now also been successfully applied outside the project's core infrastructure: A prototype for UCLA MHD description can be seen at LatHyS. Besides that IRAP is currently working on a

  19. Discharge-produced plasma extreme ultraviolet (EUV) source and ultra high vacuum chamber for studying EUV-induced processes

    CERN Document Server

    Dolgov, A; Abrikosov, A; Snegirev, E; Krivtsun, V M; Lee, C J; Bijkerk, F

    2014-01-01

    An experimental setup that directly reproduces Extreme UV-lithography relevant conditions for detailed component exposure tests is described. The EUV setup includes a pulsed plasma radiation source, operating at 13.5 nm; a debris mitigation system; collection and filtering optics; and an UHV experimental chamber, equipped with optical and plasma diagnostics. The first results, identifying the physical parameters and evolution of EUV-induced plasmas are presented. Finally, the applicability and accuracy of the in situ diagnostics is briefly discussed.

  20. Generation of metal ions in the beam plasma produced by a forevacuum-pressure electron beam source

    Energy Technology Data Exchange (ETDEWEB)

    Tyunkov, A. V.; Yushkov, Yu. G., E-mail: YuYushkov@sibmail.com; Zolotukhin, D. B.; Klimov, A. S. [Tomsk State University of Control Systems and Radioelectronics, Tomsk 634050 (Russian Federation); Savkin, K. P. [High Current Electronics Institute, Russian Academy of Sciences, Tomsk 634055 (Russian Federation)

    2014-12-15

    We report on the production of metal ions of magnesium and zinc in the beam plasma formed by a forevacuum-pressure electron source. Magnesium and zinc vapor were generated by electron beam evaporation from a crucible and subsequently ionized by electron impact from the e-beam itself. Both gaseous and metallic plasmas were separately produced and characterized using a modified RGA-100 quadrupole mass-spectrometer. The fractional composition of metal isotopes in the plasma corresponds to their fractional natural abundance.

  1. Tritium Plasma Experiment Upgrade and Improvement of Surface Diagnostic Capabilities at STAR Facility for Enhancing Tritium and Nuclear PMI Sciences

    Energy Technology Data Exchange (ETDEWEB)

    Shimada, M.; Taylor, C. N.; Pawelko, R. J.; Cadwallader, L. C.; Merrill, B. J.

    2016-04-01

    The Tritium Plasma Experiment (TPE) is a unique high-flux linear plasma device that can handle beryllium, tritium, and neutron-irradiated plasma facing materials, and is the only existing device dedicated to directly study tritium retention and permeation in neutron-irradiated materials with tritium [M. Shimada et.al., Rev. Sci. Instru. 82 (2011) 083503 and and M. Shimada, et.al., Nucl. Fusion 55 (2015) 013008]. The plasma-material-interaction (PMI) determines a boundary condition for diffusing tritium into bulk PFCs, and the tritium PMI is crucial for enhancing fundamental sciences that dictate tritium fuel cycles and safety and are high importance to an FNSF and DEMO. Recently the TPE has undergone major upgrades in its electrical and control systems. New DC power supplies and a new control center enable remote plasma operations from outside of the contamination area for tritium, minimizing the possible exposure risk with tritium and beryllium. We discuss the electrical upgrade, enhanced operational safety, improved plasma performance, and development of optical spectrometer system. This upgrade not only improves operational safety of the worker, but also enhances plasma performance to better simulate extreme plasma-material conditions expected in ITER, Fusion Nuclear Science Facility (FNSF), and Demonstration reactor (DEMO). This work was prepared for the U.S. Department of Energy, Office of Fusion Energy Sciences, under the DOE Idaho Field Office contract number DE-AC07-05ID14517.

  2. Initial evaluation and comparison of plasma damage to atomic layer carbon materials using conventional and low T{sub e} plasma sources

    Energy Technology Data Exchange (ETDEWEB)

    Jagtiani, Ashish V.; Miyazoe, Hiroyuki; Chang, Josephine; Farmer, Damon B.; Engel, Michael; Neumayer, Deborah; Han, Shu-Jen; Engelmann, Sebastian U., E-mail: suengelm@us.ibm.com; Joseph, Eric A. [IBM, T. J. Watson Research Center, Yorktown Heights, New York 10598 (United States); Boris, David R.; Hernández, Sandra C.; Walton, Scott G. [Plasma Physics Division, Naval Research Laboratory, Washington, DC 20375 (United States); Lock, Evgeniya H. [Materials Science and Technology Division, Naval Research Laboratory, Washington, DC 20375 (United States)

    2016-01-15

    The ability to achieve atomic layer precision is the utmost goal in the implementation of atomic layer etch technology. Carbon-based materials such as carbon nanotubes (CNTs) and graphene are single atomic layers of carbon with unique properties and, as such, represent the ultimate candidates to study the ability to process with atomic layer precision and assess impact of plasma damage to atomic layer materials. In this work, the authors use these materials to evaluate the atomic layer processing capabilities of electron beam generated plasmas. First, the authors evaluate damage to semiconducting CNTs when exposed to beam-generated plasmas and compare these results against the results using typical plasma used in semiconductor processing. The authors find that the beam generated plasma resulted in significantly lower current degradation in comparison to typical plasmas. Next, the authors evaluated the use of electron beam generated plasmas to process graphene-based devices by functionalizing graphene with fluorine, nitrogen, or oxygen to facilitate atomic layer deposition (ALD). The authors found that all adsorbed species resulted in successful ALD with varying impact on the transconductance of the graphene. Furthermore, the authors compare the ability of both beam generated plasma as well as a conventional low ion energy inductively coupled plasma (ICP) to remove silicon nitride (SiN) deposited on top of the graphene films. Our results indicate that, while both systems can remove SiN, an increase in the D/G ratio from 0.08 for unprocessed graphene to 0.22 to 0.26 for the beam generated plasma, while the ICP yielded values from 0.52 to 1.78. Generally, while some plasma-induced damage was seen for both plasma sources, a much wider process window as well as far less damage to CNTs and graphene was observed when using electron beam generated plasmas.

  3. Large diameter permanent-magnets-expanded plasma source for spontaneous generation of low-energy ion beam.

    Science.gov (United States)

    Takahashi, Kazunori; Suzuki, Tatsuya; Ando, Akira

    2014-02-01

    Diameter of a permanent-magnets-expanded, radiofrequency (rf) plasma source is enlarged up to ∼13 cm for an application to a space propulsion device and tested with being attached to a diffusion chamber. The source is operated at 13.56 MHz 300 W rf power in low-pressure (40 mPa) argon. Measurement of ion energy distribution functions downstream of the source exit shows generation of a supersonic ion beam of about 20 eV. The detailed radial measurements demonstrate that the diameter and energy of the ion beam corresponds to the source tube diameter and the potential difference between the source and downstream plasmas, and that the radial profile of the beam flux is similar to the plasma density profile in the source cavity.

  4. Laser-induced fluorescence measurements on plasma science experiments at PPPL

    Energy Technology Data Exchange (ETDEWEB)

    Koepke, Mark

    2011-12-20

    Collaborative research between WVU and PPPL was carried out at WVU for the purpose of incorporating the sophisticated diagnostic technique known as laser-induced fluorescence (LIF) in the Paul-Trap Simulation Experiment (PTSX) at PPPL. WVU assembled a LIF system at WVU, transported it to PPPL, helped make LIF experiments on the PTSX device, participated in PTSX science, and trained PPPL staff in LIF techniques. In summary, WVU refurbished a non-operational LIF system being loaned from University of Maryland to PPPL and, by doing so, provided PPPL with additional diagnostic capability for its PTSX device and other General Plasma Science experiments. WVU students, staff, and faculty will visit PPPL to collaborate on PTSX experiments in the future.

  5. ELM simulation experiments on Pilot-PSI using simultaneous high flux plasma and transient heat/particle source

    NARCIS (Netherlands)

    De Temmerman, G.; Zielinski, J. J.; van Diepen, S.; Marot, L.; Price, M.

    2011-01-01

    A new experimental setup has been developed for edge localized mode (ELM) simulation experiments with relevant steady-state plasma conditions and transient heat/particle source. The setup is based on the Pilot-PSI linear plasma device and allows the superimposition of a transient heat/particle pulse

  6. A versatile, pulsed anion source utilizing plasma-entrainment: Characterization and applications

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Yu-Ju; Lehman, Julia H.; Lineberger, W. Carl, E-mail: wcl@jila.colorado.edu [JILA and Department of Chemistry and Biochemistry, University of Colorado, Boulder, Colorado 80309 (United States)

    2015-01-28

    A novel pulsed anion source has been developed, using plasma entrainment into a supersonic expansion. A pulsed discharge source perpendicular to the main gas expansion greatly reduces unwanted “heating” of the main expansion, a major setback in many pulsed anion sources in use today. The design principles and construction information are described and several examples demonstrate the range of applicability of this anion source. Large OH{sup −}(Ar){sub n} clusters can be generated, with over 40 Ar solvating OH{sup −}. The solvation energy of OH{sup −}(Ar){sub n}, where n = 1-3, 7, 12, and 18, is derived from photoelectron spectroscopy and shows that by n = 12-18, each Ar is bound by about 10 meV. In addition, cis– and trans– HOCO{sup −} are generated through rational anion synthesis (OH{sup −} + CO + M → HOCO{sup −} + M) and the photoelectron spectra compared with previous results. These results, along with several further proof-of-principle experiments on solvation and transient anion synthesis, demonstrate the ability of this source to efficiently produce cold anions. With modifications to two standard General Valve assemblies and very little maintenance, this anion source provides a versatile and straightforward addition to a wide array of experiments.

  7. A versatile, pulsed anion source utilizing plasma-entrainment: Characterization and applications

    Science.gov (United States)

    Lu, Yu-Ju; Lehman, Julia H.; Lineberger, W. Carl

    2015-01-01

    A novel pulsed anion source has been developed, using plasma entrainment into a supersonic expansion. A pulsed discharge source perpendicular to the main gas expansion greatly reduces unwanted "heating" of the main expansion, a major setback in many pulsed anion sources in use today. The design principles and construction information are described and several examples demonstrate the range of applicability of this anion source. Large OH-(Ar)n clusters can be generated, with over 40 Ar solvating OH-. The solvation energy of OH-(Ar)n, where n = 1-3, 7, 12, and 18, is derived from photoelectron spectroscopy and shows that by n = 12-18, each Ar is bound by about 10 meV. In addition, cis- and trans- HOCO- are generated through rational anion synthesis (OH- + CO + M → HOCO- + M) and the photoelectron spectra compared with previous results. These results, along with several further proof-of-principle experiments on solvation and transient anion synthesis, demonstrate the ability of this source to efficiently produce cold anions. With modifications to two standard General Valve assemblies and very little maintenance, this anion source provides a versatile and straightforward addition to a wide array of experiments.

  8. Recent performance of and plasma outage studies with the SNS H- source

    Science.gov (United States)

    Stockli, M. P.; Han, B.; Murray, S. N.; Pennisi, T. R.; Piller, C.; Santana, M.; Welton, R.

    2016-02-01

    Spallation Neutron Source ramps to higher power levels that can be sustained with high availability. The goal is 1.4 MW despite a compromised radio frequency quadrupole (RFQ), which requires higher radio frequency power than design levels to approach the nominal beam transmission. Unfortunately at higher power the RFQ often loses its thermal stability, a problem apparently enhanced by beam losses and high influxes of hydrogen. Delivering as much H- beam as possible with the least amount of hydrogen led to plasma outages. The root cause is the dense 1-ms long ˜55-kW 2-MHz plasma pulses reflecting ˜90% of the continuous ˜300 W, 13-MHz power, which was mitigated with a 4-ms filter for the reflected power signal and an outage resistant, slightly detuned 13-MHz match. Lowering the H2 gas also increased the H- beam current to ˜55 mA and increased the RFQ transmission by ˜7% (relative).

  9. Submicron focusing of XUV radiation from a laser plasma source using a multilayer Laue lens

    Science.gov (United States)

    Reese, M.; Schäfer, B.; Großmann, P.; Bayer, A.; Mann, K.; Liese, T.; Krebs, H. U.

    2011-01-01

    The focusing properties of a one-dimensional multilayer Laue lens (MLL) were investigated using monochromatic soft X-ray radiation from a table-top, laser-produced plasma source. The MLL was fabricated by a focused ion beam (FIB) structuring of pulsed laser deposited ZrO2/Ti multilayers. This novel method offers the potential to overcome limitations encountered in electron lithographic processes. Utilizing this multilayer Laue lens, a line focus of XUV radiation from a laser-induced plasma in a nitrogen gas puff target could be generated. The evaluated focal length is close to the designed value of 220 μm for the measurement wavelength of 2.88 nm. Divergence angle and beam waist diameter are measured by a moving knife edge and a far-field experiment, determining all relevant second-order moments based beam parameters. The waist diameter has been found to be approximately 370 nm (FWHM).

  10. When Science and Information Literacy Meet: An Approach to Exploring the Sources of Science News with Non-Science Majors

    Science.gov (United States)

    Majetic, Cassie; Pellegrino, Catherine

    2014-01-01

    The skill set associated with lifelong scientific literacy often includes the ability to decode the content and accuracy of scientific research as presented in the media. However, students often find decoding science in the media difficult, due to limited content knowledge and shifting definitions of accuracy. Faculty have developed a variety of…

  11. Comparing Jupiter and Saturn: dimensionless input rates from plasma sources within the magnetosphere

    Directory of Open Access Journals (Sweden)

    V. M. Vasyliūnas

    2008-06-01

    Full Text Available The quantitative significance for a planetary magnetosphere of plasma sources associated with a moon of the planet can be assessed only by expressing the plasma mass input rate in dimensionless form, as the ratio of the actual mass input to some reference value. Traditionally, the solar wind mass flux through an area equal to the cross-section of the magnetosphere has been used. Here I identify another reference value of mass input, independent of the solar wind and constructed from planetary parameters alone, which can be shown to represent a mass input sufficiently large to prevent corotation already at the source location. The source rate from Enceladus at Saturn has been reported to be an order of magnitude smaller (in absolute numbers than that from Io at Jupiter. Both reference values, however, are also smaller at Saturn than at Jupiter, by factors ~40 to 60; expressed in dimensionless form, the estimated mass input from Enceladus may be larger than that from Io by factors ~4 to 6. The magnetosphere of Saturn may thus, despite a lower mass input in kg s−1, intrinsically be more heavily mass-loaded than the magnetosphere of Jupiter.

  12. Laser-plasma EUV source dedicated for surface processing of polymers

    Energy Technology Data Exchange (ETDEWEB)

    Bartnik, A., E-mail: abartnik@wat.edu.pl [Institute of Optoelectronics, Military University of Technology, 2 Kaliskiego Street, 00-908 Warsaw (Poland); Fiedorowicz, H.; Jarocki, R.; Kostecki, J.; Szczurek, M.; Wachulak, P.W. [Institute of Optoelectronics, Military University of Technology, 2 Kaliskiego Street, 00-908 Warsaw (Poland)

    2011-08-11

    In this work, a 10 Hz laser-plasma extreme ultraviolet (EUV) source built for surface processing of polymers is presented. The source is based on a double-stream gas puff target created in a vacuum chamber synchronously with the pumping laser pulse. The target is formed by pulsed injection of Kr, Xe or a KrXe gas mixture into a hollow stream of helium. The EUV radiation is focused using a grazing incidence gold-plated ellipsoidal collector. Spectrum of the reflected radiation consists of a narrow feature with intensity maximum at 10-11 nm wavelength and a long-wavelength spectral tail up to 70 nm. The exact spectral distribution depends on a gas applied for plasma creation. To avoid strong absorption of the EUV radiation in a residual gas present in the chamber during the source operation a two step differential pumping system was employed. The system allows for polymer processing under relatively high vacuum conditions (10{sup -5} mbar) or in a reactive gas atmosphere. Polymer samples can be irradiated in a focal plane of the EUV collector or at some distance downstream the focal plane. This way fluence of the EUV beam at the polymer surface can be regulated.

  13. Thermo-mechanical design of the Plasma Driver Plate for the MITICA ion source

    Energy Technology Data Exchange (ETDEWEB)

    Pavei, Mauro, E-mail: mauro.pavei@igi.cnr.it [Consorzio RFX, EURATOM-ENEA Association, Corso Stati Uniti 4, I-35127 Padova (Italy); Palma, Mauro Dalla; Marcuzzi, Diego [Consorzio RFX, EURATOM-ENEA Association, Corso Stati Uniti 4, I-35127 Padova (Italy)

    2010-12-15

    In the framework of the activities for the development of the Neutral Beam Injector (NBI) for ITER, the detailed design of the Radio-Frequency (RF) negative ion source has been carried out. One of the most heated components of the RF source is the rear vertical plate, named Plasma Driver Plate (PDP), where the Back-Streaming positive Ions (BSI+) generated from stripping losses in the accelerator and back scattered on the plasma source impinge on. The heat loads that result are huge and concentrated, with first estimate of the power densities up to 60 MW/m{sup 2}. The breakdowns that occur into the accelerator cause such heat loads to act cyclically, so that the PDP is thermo-mechanically fatigue loaded. Moreover, the surface of the PDP facing the plasma is functionally required to be temperature controlled and to be molybdenum or tungsten coated. The thermo-hydraulic design of the plate has been carried out considering active cooling with ultra-pure water. Different heat sink materials, hydraulic circuit layout and manufacturing processes have been considered. The heat exhaust has been optimized by changing the channels geometry, the path of the heat flux in the heat sink, the thickness of the plate and maximizing the Heat Transfer Coefficient. Such optimization has been carried out by utilizing 3D Finite Element (FE) models. Afterwards all the suitable mechanical (aging, structural monotonic and cyclic) verifications have been carried out post-processing the results of the thermo-mechanical 3D FE analyses in accordance to specific procedures for nuclear components exposed to high temperature. The effect of sputtering phenomenon due to the high energy BSI+ impinging on the plate has been considered and combined with fatigue damage for the mechanical verification of the PDP. Alternative solutions having molybdenum (or tungsten coatings) facing the plasma, aiming to reduce the sputtering rate and the consequent plasma pollution, have been evaluated and related 3D FE

  14. Vacuum arc with a distributed cathode spot as a plasma source for plasma separation of spent nuclear fuel and radioactive waste

    Energy Technology Data Exchange (ETDEWEB)

    Amirov, R. Kh., E-mail: ravus46@yandex.ru; Vorona, N. A.; Gavrikov, A. V.; Lizyakin, G. D.; Polishchuk, V. P.; Samoilov, I. S.; Smirnov, V. P.; Usmanov, R. A.; Yartsev, I. M. [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation)

    2015-10-15

    Results from experimental studies of a vacuum arc with a distributed cathode spot on the heated cathode are presented. Such an arc can be used as a plasma source for plasma separation of spent nuclear fuel and radioactive waste. The experiments were performed with a gadolinium cathode, the properties of which are similar to those of an uranium arc cathode. The heat flux from the plasma to the cathode (and its volt equivalent) at discharge voltages of 4-15 V and discharge currents of 44-81 A, the radial distribution of the emission intensity of gadolinium atoms and singly charged ions in the arc channel at a voltage of 4.3 V, and the plasma electron temperature behind the anode were measured. The average charge of plasma ions at arc voltages of 3.5-8 V and a discharge current of 52 A and the average rate of gadolinium evaporation in the discharge were also determined.

  15. Catalytic action of β source on x-ray emission from plasma focus

    Science.gov (United States)

    Ahmad, S.; Sadiq, Mehboob; Hussain, S.; Shafiq, M.; Zakaullah, M.; Waheed, A.

    2006-01-01

    The influence of preionization around the insulator sleeve by a mesh-type β source (Ni6328) for the x-ray emission from a (2.3-3.9 kJ) plasma focus device is investigated. Quantrad Si p-i-n diodes along with suitable filters are employed as time-resolved x-ray detectors and a multipinhole camera with absorption filters is used for time-integrated analysis. X-ray emission in 4π geometry is measured as a function of argon and hydrogen gas filling pressures with and without β source at different charging voltages. It is found that the pressure range for the x-ray emission is broadened, x-ray emission is enhanced, and shot to shot reproducibility is improved with the β source. With argon, the CuKα emission is estimated to be 27.14 J with an efficiency of 0.7% for β source and 21.5 J with an efficiency of 0.55% without β source. The maximum x-ray yield in 4π geometry is found to be about 68.90 J with an efficiency of 1.8% for β source and 54.58 J with an efficiency of 1.4% without β source. With hydrogen, CuKα emission is 11.82 J with an efficiency of 0.32% for β source and 10.07 J with an efficiency of 0.27% without β source. The maximum x-ray yield in 4π geometry is found to be 30.20 J with an efficiency of 0.77% for β source and 25.58 J with an efficiency of 0.6% without β source. The x-ray emission with Pb insert at the anode tip without β source is also investigated and found to be reproducible and significantly high. The maximum x-ray yield is estimated to be 46.6 J in 4π geometry with an efficiency of 1.4% at 23 kV charging voltage. However, degradation of x-ray yield is observed when charging voltage exceeds 23 kV for Pb insert. From pinhole images it is observed that the x-ray emission due to the bombardment of electrons at the anode tip is dominant in both with and without β source.

  16. Compact Cryogenic Source of Periodic Hydrogen and Argon Droplet Beams for Intense Laser-Plasma Generation

    CERN Document Server

    Fraga, R A Costa; Kühnel, M; Hochhaus, D C; Schottelius, A; Polz, J; Kaluza, M C; Neumayer, P; Grisenti, R E

    2011-01-01

    We present a cryogenic source of periodic streams of micrometer-sized hydrogen (H2) and argon (Ar) droplets as ideal mass-limited target systems for fundamental intense laser-driven plasma applications. The highly compact design combined with a high temporal and spatial droplet stability makes our injector ideally suited for experiments using state-of-the-art low-repetition rate high-power lasers, in which a precise synchronization between the laser pulses and the droplets is mandatory. We demonstrate this explicitly by irradiating Ar droplets with pulses from a Petawatt laser.

  17. Compact cryogenic source of periodic hydrogen and argon droplet beams for relativistic laser-plasma generation

    Energy Technology Data Exchange (ETDEWEB)

    Fraga, R. A. Costa; Kalinin, A.; Kuehnel, M.; Schottelius, A. [Institut fuer Kernphysik, J. W. Goethe-Universitaet, Max-von-Laue-Str. 1, 60438 Frankfurt am Main (Germany); Hochhaus, D. C.; Neumayer, P. [EMMI Extreme Matter Institute and Research Division, GSI Helmholtzzentrum fuer Schwerionenforschung, Planckstr. 1, 64291 Darmstadt (Germany); FIAS Frankfurt Institute for Advanced Studies, J. W. Goethe-Universitaet, Ruth-Moufang-Str. 1, 60438 Frankfurt am Main (Germany); Polz, J. [Institut fuer Optik und Quantenelektronik, Max-Wien-Platz 1, 07743 Jena (Germany); Kaluza, M. C. [Institut fuer Optik und Quantenelektronik, Max-Wien-Platz 1, 07743 Jena (Germany); Helmholtz-Institut Jena, Froebelstieg 3, 07743 Jena (Germany); Grisenti, R. E. [Institut fuer Kernphysik, J. W. Goethe-Universitaet, Max-von-Laue-Str. 1, 60438 Frankfurt am Main (Germany); GSI Helmholtzzentrum fuer Schwerionenforschung, Planckstr. 1, 64291 Darmstadt (Germany)

    2012-02-15

    We present a cryogenic source of periodic streams of micrometer-sized hydrogen and argon droplets as ideal mass-limited target systems for fundamental intense laser-driven plasma applications. The highly compact design combined with a high temporal and spatial droplet stability makes our injector ideally suited for experiments using state-of-the-art high-power lasers in which a precise synchronization between the laser pulses and the droplets is mandatory. We show this by irradiating argon droplets with multi-terawatt pulses.

  18. Diagnosis of Hydrogen Plasma in a Miniature Penning Ion Source by Double Probes

    Institute of Scientific and Technical Information of China (English)

    JIN Dazhi; YANG Zhonghai; XIAO Kunxiang; DAI Jingyi

    2009-01-01

    Parameters of hydrogen plasma in a miniature Penning discharge ion source,including the electron temperature and the electron density,were measured by using double probes.The results indicate that the electron density increases and the electron temperature decreases with the increase in gas pressure and the discharge current.The electron temperature is about 5~9 eV and the electron density is 6.0x1013~1.2×1014 m-3 while the discharge current is in a range of 50~12μA.

  19. Interaction of plasmas in laser ion source with double laser system

    Energy Technology Data Exchange (ETDEWEB)

    Fuwa, Y., E-mail: yasuhiro.fuwa@riken.jp [Graduate School of Science, Kyoto University, Kyoto (Japan); Riken, Wako, Saitama (Japan); Ikeda, S. [Riken, Wako, Saitama (Japan); Interdisciplinary Graduate School of Science and Engineering, Tokyo Institute of Technology, Yokohama, Tokyo (Japan); Kumaki, M. [Riken, Wako, Saitama (Japan); Research Institute for Science and Engineering, Waseda University, Shinjuku, Tokyo (Japan); Sekine, M. [Riken, Wako, Saitama (Japan); Department of Nuclear Engineering, Tokyo Institute of Technology, Meguro, Tokyo (Japan); Cinquegrani, D. [Nuclear Engineering and Radiological Science, University of Michigan, Ann Arbor, Michigan 48109 (United States); Romanelli, M. [School of Applied and Engineering Physics, Cornell University, Ithaca, New York 14850 (United States); Kanesue, T.; Okamura, M. [Collider-Accelerator Department, Brookhaven National Laboratory, Upton, New York 11973 (United States); Iwashita, Y. [Institute for Chemical Research, Kyoto University, Uji, Kyoto (Japan)

    2014-02-15

    Multiple laser shots could be used to elongate an ion beam pulse width or to intensify beam current from laser ion sources. In order to confirm the feasibility of the multiple shot scheme, we investigated the properties of plasmas produced by double laser shots. We found that when the interval of the laser shots is shorter than 10 μs, the ion current profile had a prominent peak, which is not observed in single laser experiments. The height of this peak was up to five times larger than that of single laser experiment.

  20. Simulation methods of ion sheath dynamics in plasma source ion implantation

    Institute of Scientific and Technical Information of China (English)

    WANG Jiuli; ZHANG Guling; WANG Younian; LIU Yuanfu; LIU Chizi; YANG Size

    2004-01-01

    Progress of the theoretical studies on the ion sheath dynamics in plasma source ion implantation (PSII) is reviewed in this paper. Several models for simulating the ion sheath dynamics in PSII are provided. The main problem of nonuniform ion implantation on the target in PSII is discussed by analyzing some calculated results. In addition, based on the relative researches in our laboratory, some calculated results of the ion sheath dynamics in PSII for inner surface modification of a cylindrical bore are presented. Finally, new ideas and tendency for future researches on ion sheath dynamics in PSII are proposed.

  1. A laser-generated plasma as a source of VUV continuum radiation for photoelectronic spectroscopy

    OpenAIRE

    Heckenkamp, Ch.; Heinzmann, Ulrich; Schönhense, G.; BURGESS.D.D; Thorne, A. P.; Wheaton, J. E. G.

    1981-01-01

    The feasibility of using laser-generated plasmas as VUV continuum sources for photoelectron spectroscopy has been demonstrated by measuring the spectral intensity distribution of the VUV continuum in the wavelength region from 79 to 43 nm by energy analysis of the photoelectrons ejected from argon atoms. The maximum photon flux obtained after reflection at a gold-coated spherical mirror was of the order of 10(11) photons nm(-1) per pulse at 50 nm for a laser energy of 830 mJ. The results show...

  2. Particle flux at the outlet of an Ecr plasma source; Flujos de particulas a la salida de una fuente de plasma ECR

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez T, C.; Gonzalez D, J. [ININ, Departamento de Fisica, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2000-07-01

    The necessity of processing big material areas this has resulted in the development of plasma sources with the important property to be uniform in these areas. Also the continuous diminution in the size of substrates to be processed have stimulated the study of models which allow to predict the control of energy and the density of the ions and neutral particles toward the substrate. On the other hand, there are other applications of the plasma sources where it is very necessary to understand the effects generated by the energetic fluxes of ions and neutrals. These fluxes as well as another beneficial effects can improve the activation energy for the formation and improvement of the diffusion processes in the different materials. In this work, using the drift kinetic approximation is described a model to calculate the azimuthal and radial fluxes in the zone of materials processing of an Ecr plasma source type. The results obtained are compared with experimental results. (Author)

  3. Increasing the Number of Women and Underrepresented Minorities in the Plasma Science-A Case Study

    Science.gov (United States)

    Lucas, Pamela R.; Post-Zwicker, Andrew

    2000-10-01

    The number of women and underrepresented minorities in plasma science is woefully small.The Princeton Plasma Physics Laboratory (PPPL), for example, consists of 2% women and underrepresented minorities. The historical reasons for this specific case as well as the overall circumstances involving pipeline inclusion are beyond the scope of this paper. The answer, however, is clearly NOT a lack of qualified women and minorities as evidenced by the numbers in other SEM disciplines such as computer science where women earn 27% of the doctoral degrees, African Americans 10% and Hispanics 5%. Over the past five years the number of underrepresented minorities earning degrees in physics and engineering has risen. Since 1995, in an effort to reach this population, PPPL has actively recruited women and underrepresented minority students to its various undergraduate research programs, in particular the National Undergraduate Fellowship Program (NUF) and the Energy Research Undergraduate Laboratory Fellowship (ERULF). The results are encouraging. The details of our efforts, our future plans, and ways of introducing our methods to other laboratories will be discussed.

  4. Synchrotron x-ray sources and new opportunities in the soil and environmental sciences

    Energy Technology Data Exchange (ETDEWEB)

    Schulze, D. (Purdue Univ., Lafayette, IN (USA)); Anderson, S. (Michigan State Univ., East Lansing, MI (USA)); Mattigod, S. (Pacific Northwest Lab., Richland, WA (USA))

    1990-07-01

    This report contains the following papers: characteristics of the advanced photon source and comparison with existing synchrotron facilities; x-ray absorption spectroscopy: EXAFS and XANES -- A versatile tool to study the atomic and electronic structure of materials; applications of x-ray spectroscopy and anomalous scattering experiments in the soil and environmental sciences; X-ray fluorescence microprobe and microtomography.

  5. OpenSesame : An open-source, graphical experiment builder for the social sciences

    NARCIS (Netherlands)

    Mathot, Sebastiaan; Schreij, Daniel; Theeuwes, Jan

    2012-01-01

    In the present article, we introduce OpenSesame, a graphical experiment builder for the social sciences. OpenSesame is free, open-source, and cross-platform. It features a comprehensive and intuitive graphical user interface and supports Python scripting for complex tasks. Additional functionality,

  6. Agricultural Science Teachers' Barriers, Roles, and Information Source Preferences for Teaching Biotechnology Topics

    Science.gov (United States)

    Mowen, Diana L.; Wingenbach, Gary J.; Roberts, T. Grady; Harlin, Julie F.

    2007-01-01

    The purpose of this study was to determine barriers, roles, and information source preferences for teaching agricultural biotechnology topics. Agricultural science teachers were described primarily as 37 year-old males who had taught for 12 years, had bachelor's degrees, and had lived or worked on a farm or ranch. Equipment was perceived as the…

  7. Drawing and Writing in Digital Science Notebooks: Sources of Formative Assessment Data

    Science.gov (United States)

    Shelton, Angi; Smith, Andrew; Wiebe, Eric; Behrle, Courtney; Sirkin, Ruth; Lester, James

    2016-01-01

    Formative assessment strategies are used to direct instruction by establishing where learners' understanding is, how it is developing, informing teachers and students alike as to how they might get to their next set of goals of conceptual understanding. For the science classroom, one rich source of formative assessment data about scientific…

  8. The Danish National Hospital Register. A valuable source of data for modern health sciences

    DEFF Research Database (Denmark)

    Andersen, T F; Madsen, Mette; Jørgensen, J

    1999-01-01

    as in collaboration with international teams, and the LPR is truly a valuable source of data for health sciences, especially in epidemiology, health services research and clinical research. Nearly complete registration of somatic hospital events in Denmark is combined with ideal conditions for longterm follow-up due...

  9. Numerical study of plasma generation process and internal antenna heat loadings in J-PARC RF negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, T., E-mail: shibat@post.j-parc.jp; Ueno, A.; Oguri, H.; Ohkoshi, K.; Ikegami, K.; Takagi, A.; Asano, H.; Naito, F. [J-PARC Center, Tokai-mura, Naka-gun, Ibaraki-ken 319-1195 (Japan); Nishida, K.; Mochizuki, S.; Hatayama, A. [Keio University, Hiyoshi, Kohoku-ku, Yokohama-shi, Kanagawa-ken 223-8522 (Japan); Mattei, S.; Lettry, J. [European Organization for Nuclear Research (CERN), 1211 Geneva 23 (Switzerland)

    2016-02-15

    A numerical model of plasma transport and electromagnetic field in the J-PARC (Japan Proton Accelerator Research Complex) radio frequency ion source has been developed to understand the relation between antenna coil heat loadings and plasma production/transport processes. From the calculation, the local plasma density increase is observed in the region close to the antenna coil. Electrons are magnetized by the magnetic field line with absolute magnetic flux density 30–120 Gauss which leads to high local ionization rate. The results suggest that modification of magnetic configuration can be made to reduce plasma heat flux onto the antenna.

  10. submitter Numerical study of plasma generation process and internal antenna heat loadings in J-PARC RF negative ion source

    CERN Document Server

    Shibata, T; Mochizuki, S; Mattei, S; Lettry, J; Hatayama, A; Ueno, A; Oguri, H; Ohkoshi, K; Ikegami, K; Takagi, A; Asano, H; Naito, F

    2016-01-01

    A numerical model of plasma transport and electromagnetic field in the J-PARC (Japan Proton Accelerator Research Complex) radio frequency ion source has been developed to understand the relation between antenna coil heat loadings and plasma production/transport processes. From the calculation, the local plasma density increase is observed in the region close to the antenna coil. Electrons are magnetized by the magnetic field line with absolute magnetic flux density 30-120 Gauss which leads to high local ionization rate. The results suggest that modification of magnetic configuration can be made to reduce plasma heat flux onto the antenna.

  11. Towards virtual knowledge broker services for semantic integration of life science literature and data sources.

    Science.gov (United States)

    Harrow, Ian; Filsell, Wendy; Woollard, Peter; Dix, Ian; Braxenthaler, Michael; Gedye, Richard; Hoole, David; Kidd, Richard; Wilson, Jabe; Rebholz-Schuhmann, Dietrich

    2013-05-01

    Research in the life sciences requires ready access to primary data, derived information and relevant knowledge from a multitude of sources. Integration and interoperability of such resources are crucial for sharing content across research domains relevant to the life sciences. In this article we present a perspective review of data integration with emphasis on a semantics driven approach to data integration that pushes content into a shared infrastructure, reduces data redundancy and clarifies any inconsistencies. This enables much improved access to life science data from numerous primary sources. The Semantic Enrichment of the Scientific Literature (SESL) pilot project demonstrates feasibility for using already available open semantic web standards and technologies to integrate public and proprietary data resources, which span structured and unstructured content. This has been accomplished through a precompetitive consortium, which provides a cost effective approach for numerous stakeholders to work together to solve common problems.

  12. Inductively coupled plasma mass spectrometry (ICP-MS)and its application in life sciences

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Inductively-coupled plasma mass spectrometry (ICP-MS) has made much progress since its birth in the late 1990s. This paper will give a rather systematic overview on the use of this technique in new devices and technologies related to plasma source, sample-introducing device and detecting spectrometer etc. In this overview, an emphasis will be put on the evaluation of the ICPMS technique in combination with a series of physical, chemical and biological techniques, such as laser ablation (LA), capillary electrophoresis (CE) and high performance liquid chromatograph (HPLC), along with their representative high accuracy and high sensitivity. Finally, comprehensive and fruitful applications of the ICP-MS and its combinative techniques in the detection of trace metallic elements and isotopes in complex biological and environmental samples will be revealed.

  13. Transition of the BELLA PW laser system towards a collaborative research facility in laser plasma science

    Science.gov (United States)

    Toth, Csaba; Evans, Dave; Gonsalves, Anthony J.; Kirkpatrick, Mark; Magana, Art; Mannino, Greg; Mao, Hann-Shin; Nakamura, Kei; Riley, Joe R.; Steinke, Sven; Sipla, Tyler; Syversrud, Don; Ybarrolaza, Nathan; Leemans, Wim P.

    2017-03-01

    The advancement of Laser-Plasma Accelerators (LPA) requires systematic studies with ever increasing precision and reproducibility. A key component of such a research endeavor is a facility that provides reliable, well characterized laser sources, flexible target systems, and comprehensive diagnostics of the laser pulses, the interaction region, and the produced electron beams. The Berkeley Lab Laser Accelerator (BELLA), a PW laser facility, now routinely provides high quality focused laser pulses for high precision experiments. A description of the commissioning process, the layout of the laser systems, the major components of the laser and radiation protection systems, and a summary of early results are given. Further scientific plans and highlights of operational experience that serve as the basis for transition to a collaborative research facility in high-peak power laser-plasma interaction research are reviewed.

  14. Electron cyclotron resonance ion source plasma chamber studies using a network analyzer as a loaded cavity probe

    Energy Technology Data Exchange (ETDEWEB)

    Toivanen, V.; Tarvainen, O.; Kauppinen, J.; Komppula, J.; Koivisto, H. [Department of Physics, University of Jyvaeskylae, Jyvaeskylae 40500 (Finland); Lyneis, C. [Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States)

    2012-02-15

    A method and first results utilizing a network analyzer as a loaded cavity probe to study the resonance properties of a plasma filled electron cyclotron resonance ion source (ECRIS) plasma chamber are presented. The loaded cavity measurements have been performed using a dual port technique, in which two separate waveguides were used simultaneously. One port was used to ignite and sustain the plasma with a microwave source operating around 11 GHz and the other was used to probe the cavity properties with the network analyzer using a frequency range around 14 GHz. The first results obtained with the JYFL 14 GHz ECRIS demonstrate that the presence of plasma has significant effects on the resonance properties of the cavity. With plasma the frequency dependent behavior is strongly damped and this trend strengthens with increasing microwave power.

  15. Frequency-tuning radiofrequency plasma source operated in inductively-coupled mode under a low magnetic field

    Science.gov (United States)

    Takahashi, Kazunori; Nakano, Yudai; Ando, Akira

    2017-07-01

    A radiofrequency (rf) inductively-coupled plasma source is operated with a frequency-tuning impedance matching system, where the rf frequency is variable in the range of 20-50 MHz and the maximum power is 100 W. The source consists of a 45 mm-diameter pyrex glass tube wound by an rf antenna and a solenoid providing a magnetic field strength in the range of 0-200 Gauss. A reflected rf power for no plasma case is minimized at the frequency of ˜25 MHz, whereas the frequency giving the minimum reflection with the high density plasma is about 28 MHz, where the density jump is observed when minimizing the reflection. A high density argon plasma above 1× {{10}12} cm-3 is successfully obtained in the source for the rf power of 50-100 W, where it is observed that an external magnetic field of a few tens of Gauss yields the highest plasma density in the present configuration. The frequency-tuning plasma source is applied to a compact and high-speed silicon etcher in an Ar-SF6 plasma; then the etching rate of 8~μ m min-1 is obtained for no bias voltage to the silicon wafer, i.e. for the case that a physical ion etching process is eliminated.

  16. Waveguide slot-excited long racetrack electron cyclotron resonance plasma source for roll-to-roll (scanning) processing.

    Science.gov (United States)

    You, H-J

    2013-07-01

    We present a SLot-excited ANtenna (SLAN) long racetrack ECR plasma source that is utilized for roll-to-roll plasma processing such as thin film encapsulation of large-area OLED (organic light emitting diode) panel or modification of fabric surfaces. This source is designed to be long, and to operate under high density uniform plasma with sub-milli-torr pressures. The above features are accomplished by a slot-excited long racetrack resonator with a toroidal geometry of magnetic field ECR configuration, and reinforced microwave electric distributions along the central region of plasma chamber. Also, a new feature has been added to the source. This is to employ a tail plunger, which allows the microwave electric field and the uniformity of the plasma profile to be easily adjustable. We have successfully generated Ar plasmas operating with the microwave power of 0.5-3 kW in the pressure range of 0.2-10 mTorr. The plasma is uniform (racetrack-SLAN source.

  17. Concept of a laser-plasma based electron source for sub-10 fs electron diffraction

    CERN Document Server

    Faure, J; Beaurepaire, B; Gallé, G; Vernier, A; Lifschitz, A

    2015-01-01

    We propose a new concept of an electron source for ultrafast electron diffraction with sub-10~fs temporal resolution. Electrons are generated in a laser-plasma accelerator, able to deliver femtosecond electron bunches at 5 MeV energy with kHz repetition rate. The possibility of producing this electron source is demonstrated using Particle-In-Cell simulations. We then use particle tracking simulations to show that this electron beam can be transported and manipulated in a realistic beamline, in order to reach parameters suitable for electron diffraction. The beamline consists of realistic static magnetic optics and introduces no temporal jitter. We demonstrate numerically that electron bunches with 5~fs duration and containing 1.5~fC per bunch can be produced, with a transverse coherence length exceeding 2~nm, as required for electron diffraction.

  18. Feasibility analysis of a Plasma Focus neutron source for BNCT treatment of transplanted human liver

    Science.gov (United States)

    Benzi, V.; Mezzetti, F.; Rocchi, F.; Sumini, M.

    2004-01-01

    Boron Neutron Capture Therapy preliminary treatments on transplanted human liver have been recently conducted at Pavia University. The need of high fluences of thermal neutrons imposed the use of the available thermal channel of a TRIGA reactor properly modified for this application. We analyse the possibility of using the Plasma Focus (PF) machine as a pulsed neutron source for this medical application instead of a nuclear reactor. Thermalization of the fast (2.45 MeV for D-D reactions) neutrons produced by the PF is gained with a paraffin or polyethylene moderator which contains both the neutron source and the irradiation chamber. The design parameters of a PF optimized for such an application are discussed, as well as other considerations on the advantages that this machine can bring to this kind of cancer therapy.

  19. Spatially resolved optical-emission spectroscopy of a radio-frequency driven iodine plasma source

    Science.gov (United States)

    Dedrick, James; Doyle, Scott; Grondein, Pascaline; Aanesland, Ane

    2016-09-01

    Iodine is of interest for potential use as a propellant for spacecraft propulsion, and has become attractive as a replacement to xenon due to its similar mass and ionisation potential. Optical emission spectroscopy has been undertaken to characterise the emission from a low-pressure, radio-frequency driven inductively coupled plasma source operating in iodine with respect to axial distance across its transverse magnetic filter. The results are compared with axial profiles of the electron temperature and density for identical source conditions, and the spatial distribution of the emission intensity is observed to be closely correlated with the electron temperature. This work has been done within the LABEX Plas@Par project, and received financial state aid managed by the ``Agence Nationale de la Recherche'', as part of the ``Programme d'Investissements d'Avenir'' under the reference ANR-11-IDEX-0004-02.

  20. MIT modular x-ray source systems for the study of plasma diagnostics

    Science.gov (United States)

    Coleman, J. W.; Wenzel, K. W.; Petrasso, R. D.; Lo, D. H.; Li, C. K.; Lierzer, J. R.; Wei, T.

    1992-10-01

    Two new x-ray source systems are now on line at our facility. Each provides an e-beam to 25 kV. Targets are interchangeable between machines, and four x-ray detectors may be used simultaneously with a target. The gridded e-gun of the RACEHORSE system gives a 0.5-1.0-cm pulsable spot on target. The nongridded e-gun of the SCORPION system provides a 0.3-mm or smaller dc microspot on target. RACEHORSE is being used to study and characterize type-II diamond photoconductors for use in diagnosing plasmas, while SCORPION is being used to develop a slitless spectrograph using photographic film. Source design details and some RACEHORSE results are presented.

  1. Tunable room temperature terahertz sources based on two dimensional plasma instability in GaN HEMTs

    Science.gov (United States)

    El Fatimy, A.; Suemitsu, T.; Otsuji, T.; Dyakonova, N.; Knap, W.; Meziani, Y. M.; Vandenbrouk, S.; Madjour, K.; Théron, D.; Gaquiere, Ch; Prystawko, P.; Skierbiszewski, C.

    2009-11-01

    In this work, we report on room temperature terahertz radiation from sub-micron size GaN/AlGaN based high electron mobility transistors (HEMTs). They could successfully replace the standard Fourier Transform spectrometer source and were investigated with a standard Si-bolometer as a detector. The relatively broad (~1THz) emission line was observed. The maxima were found to be tunable by the gate voltage between 0.75 and 2.1 THz. The observed emission was interpreted as due to the current driven plasma waves instability in the two-dimensional electron gas. The emitted power from a single device reached 150 nW, showing possible application of these transistors as compact sources for terahertz spectroscopy and imaging.

  2. Tunable room temperature terahertz sources based on two dimensional plasma instability in GaN HEMTs

    Energy Technology Data Exchange (ETDEWEB)

    Fatimy, A El; Suemitsu, T; Otsuji, T; Knap, W [Research Institute of Electrical Communication (RIEC), Tohoku University, 2-1-1 Katahira, Aoba-Ku, 980-8577, Sendai (Japan); Dyakonova, N [Groupe d' Etude des Semiconducteurs, UMR CNRS 5650, Universite Montpellier 2, 34095 Montpellier (France); Meziani, Y M [Dpto. de Fisica Aplicada, Universidad de Salamanca, Plaza de la Merced s/n, 37008 Salamanca (Spain); Vandenbrouk, S; Madjour, K; Theron, D; Gaquiere, Ch [Institut d' Electronique et de Microelectronique du Nord, UMR CNRS 8520, 59655 Villeneuve d' Acsq (France); Prystawko, P; Skierbiszewski, C, E-mail: a.elfatimy@riec.tohoku.ac.j, E-mail: ElFatimyA@cardiff.ac.u [Institutes of High Pressure Physics, PAS, Unipress, Sokolowska 29/37, 01-142 Warsaw (Poland)

    2009-11-15

    In this work, we report on room temperature terahertz radiation from sub-micron size GaN/AlGaN based high electron mobility transistors (HEMTs). They could successfully replace the standard Fourier Transform spectrometer source and were investigated with a standard Si-bolometer as a detector. The relatively broad ({approx}1THz) emission line was observed. The maxima were found to be tunable by the gate voltage between 0.75 and 2.1 THz. The observed emission was interpreted as due to the current driven plasma waves instability in the two-dimensional electron gas. The emitted power from a single device reached 150 nW, showing possible application of these transistors as compact sources for terahertz spectroscopy and imaging.

  3. Temperature of the Source Plasma in Gradual Solar Energetic Particle Events

    CERN Document Server

    Reames, Donald V

    2015-01-01

    Scattering, during interplanetary transport in large, "gradual" solar energetic-particle (SEP) events, can cause element abundance enhancements or suppressions that depend upon the mass-to-charge ratio A/Q of the ions as an increasing power law early in events and a decreasing power law of the residual ions later. Since the Q values for the ions depend upon the source plasma temperature T, best fits to the power-law dependence of enhancements vs. A/Q provide a fundamentally new method to determine the most probable value of T for these events. We find that fits to the times of increasing and decreasing powers give similar values of T, most commonly (69%) in the range of 0.8-1.6 MK, consistent with the acceleration of ambient coronal plasma by shock waves driven out from the Sun by coronal mass ejections (CMEs). However, 24% of the SEP events studied showed plasma of 2.5-3.2 MK, typical of that previously determined for the smaller impulsive SEP events; these particles may be reaccelerated preferentially by qu...

  4. Investigation of helium ion production in constricted direct current plasma ion source with layered-glows

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yuna [Department of Nuclear Engineering, Seoul National University, Seoul 151-744 (Korea, Republic of); Chung, Kyoung-Jae, E-mail: jkjlsh1@snu.ac.kr [Center for Advance Research in Fusion Reactor Engineering, Seoul National University, Seoul 151-744 (Korea, Republic of); Park, Yeong-Shin [Samsumg Electronics Co. Ltd., Gyeonggi 445-701 (Korea, Republic of); Hwang, Y. S. [Department of Nuclear Engineering, Seoul National University, Seoul 151-744 (Korea, Republic of); Center for Advance Research in Fusion Reactor Engineering, Seoul National University, Seoul 151-744 (Korea, Republic of)

    2014-02-15

    Generation of helium ions is experimentally investigated with a constricted direct current (DC) plasma ion source operated at layered-glow mode, in which electrons could be accelerated through multiple potential structures so as to generate helium ions including He{sup 2+} by successive ionization collisions in front of an extraction aperture. The helium discharge is sustained with the formation of a couple of stable layers and the plasma ball with high density is created near the extraction aperture at the operational pressure down to 0.6 Torr with concave cathodes. The ion beam current extracted with an extraction voltage of 5 kV is observed to be proportional to the discharge current and inversely proportional to the operating pressure, showing high current density of 130 mA/cm{sup 2} and power density of 0.52 mA/cm{sup 2}/W. He{sup 2+} ions, which were predicted to be able to exist due to multiple-layer potential structure, are not observed. Simple calculation on production of He{sup 2+} ions inside the plasma ball reveals that reduced operating pressure and increased cathode area will help to generate He{sup 2+} ions with the layered-glow DC discharge.

  5. Investigation of the dynamics of the Z-pinch imploding plasma for a laser-assisted discharge-produced Sn plasma EUV source

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Q; Yamada, J; Kishi, N; Watanabe, M; Okino, A; Horioka, K; Hotta, E, E-mail: zhu.q.ab@m.titech.ac.jp [Department of Energy Sciences, Tokyo Institute of Technology, Nagatsuta 4259 J2-35, Midori-ku, Yokohama 226-8502 (Japan)

    2011-04-13

    Dynamics of the imploding plasma and its relations to the 13.5 nm EUV emissions have been experimentally investigated for a laser-assisted Sn based discharge-produced plasma EUV source. The behaviours and two-dimensional electron density distributions of the EUV-emitting plasma were obtained using the time-resolved shadowgraph and Nomarski interferometric techniques. Observation of the plasma piston in the prepinch phase justified the validity of the zero-dimensional thin-shell model, from which the ion charge state of the prepinch plasma in the cathode region was estimated. The sausage (m = 0) instability that usually enhances the EUV emission was observed, with the radial electron density distribution that displays a concave shape at the crest of the plasma and a bell shape at the neck; the maximum of the electron density is located at one peak of the concave distribution at the crest instead of the neck. Intense EUV emission was produced by the Z-pinch plasma with the electron density (2.0-3.0) x 10{sup 18} cm{sup -3}. Moreover, the shock waves generated in the anode region can also produce in-band EUV emission with the intensity of 30% of that from the Z-pinch plasma.

  6. Development of a compact laser-produced plasma soft X-ray source for radiobiology experiments

    Energy Technology Data Exchange (ETDEWEB)

    Adjei, Daniel, E-mail: nana.adjeidan@gmail.com [Institute of Optoelectronics, Military University of Technology, 2, Kaliskiego Str., 00-908 Warsaw (Poland); Radiation Protection Institute, Ghana Atomic Energy Commission, P.O. Box LG 80, Legon, Accra (Ghana); Ayele, Mesfin Getachew; Wachulak, Przemyslaw; Bartnik, Andrzej; Wegrzynski, Łukasz; Fiedorowicz, Henryk [Institute of Optoelectronics, Military University of Technology, 2, Kaliskiego Str., 00-908 Warsaw (Poland); Vyšín, Luděk [Institute of Physics, Czech Academy of Sciences, Na Slovance 2, 182 21 Prague 8 (Czech Republic); Faculty of Nuclear Sciences and Engineering Physics, Czech Technical University in Prague, Břehová 7, 115 19 Prague 1 (Czech Republic); Wiechec, Anna; Lekki, Janusz; Kwiatek, Wojciech M. [Institute of Nuclear Physics, Polish Academy of Sciences, 152, Radzikowskiego Str., 31-342 Cracow (Poland); Pina, Ladislav [Faculty of Nuclear Sciences and Engineering Physics, Czech Technical University in Prague, Břehová 7, 115 19 Prague 1 (Czech Republic); Davídková, Marie [Institute of Nuclear Physics, Czech Academy of Sciences, Řež (Czech Republic); Juha, Libor [Institute of Physics, Czech Academy of Sciences, Na Slovance 2, 182 21 Prague 8 (Czech Republic)

    2015-12-01

    A desk-top laser-produced plasma (LPP) source of soft X-rays (SXR) has been developed for radiobiology research. The source is based on a double-stream gas puff target, irradiated with the focused beam of a commercial Nd:YAG laser. The source has been optimized to get a maximum photon emission from LPP in the X-ray “water window” spectral wavelength range from 2.3 nm (i.e., an absorption edge of oxygen) to 4.4 nm (i.e., an absorption edge of carbon) (280–540 eV in photon energy units) by using argon gas-puff target and spectral filtering by free-standing thin foils. The present source delivers nanosecond pulses of soft X-rays at a fluence of about 4.2 × 10{sup 3} photons/μm{sup 2}/pulse on a sample placed inside the vacuum chamber. In this paper, the source design, radiation output characterization measurements and initial irradiation experiments are described. The source can be useful in addressing observations related to biomolecular, cellular and organisms’ sensitivity to pulsed radiation in the “water window”, where carbon atoms absorb X-rays more strongly than the oxygen, mostly present in water. The combination of the SXR source and the radiobiology irradiation layout, reported in this article, make possible a systematic investigation of relationships between direct and indirect action of ionizing radiation, an increase of a local dose in carbon-rich compartments of the cell (e.g., lipid membranes), an experimental estimation of a particular role of the Auger effect (in particular in carbon atoms) in the damage to biological systems, and the study of ionization/excitation-density (LET – Linear Energy Transfer) and dose-rate effects in radiobiology.

  7. Development of a compact laser-produced plasma soft X-ray source for radiobiology experiments

    Science.gov (United States)

    Adjei, Daniel; Ayele, Mesfin Getachew; Wachulak, Przemyslaw; Bartnik, Andrzej; Wegrzynski, Łukasz; Fiedorowicz, Henryk; Vyšín, Luděk; Wiechec, Anna; Lekki, Janusz; Kwiatek, Wojciech M.; Pina, Ladislav; Davídková, Marie; Juha, Libor

    2015-12-01

    A desk-top laser-produced plasma (LPP) source of soft X-rays (SXR) has been developed for radiobiology research. The source is based on a double-stream gas puff target, irradiated with the focused beam of a commercial Nd:YAG laser. The source has been optimized to get a maximum photon emission from LPP in the X-ray "water window" spectral wavelength range from 2.3 nm (i.e., an absorption edge of oxygen) to 4.4 nm (i.e., an absorption edge of carbon) (280-540 eV in photon energy units) by using argon gas-puff target and spectral filtering by free-standing thin foils. The present source delivers nanosecond pulses of soft X-rays at a fluence of about 4.2 × 103 photons/μm2/pulse on a sample placed inside the vacuum chamber. In this paper, the source design, radiation output characterization measurements and initial irradiation experiments are described. The source can be useful in addressing observations related to biomolecular, cellular and organisms' sensitivity to pulsed radiation in the "water window", where carbon atoms absorb X-rays more strongly than the oxygen, mostly present in water. The combination of the SXR source and the radiobiology irradiation layout, reported in this article, make possible a systematic investigation of relationships between direct and indirect action of ionizing radiation, an increase of a local dose in carbon-rich compartments of the cell (e.g., lipid membranes), an experimental estimation of a particular role of the Auger effect (in particular in carbon atoms) in the damage to biological systems, and the study of ionization/excitation-density (LET - Linear Energy Transfer) and dose-rate effects in radiobiology.

  8. Direct structuring of solids by EUV radiation from a table-top laser produced plasma source

    Science.gov (United States)

    Barkusky, Frank; Bayer, Armin; Peth, Christian; Mann, Klaus

    2009-05-01

    In recent years, technological developments in the area of extreme ultraviolet lithography (EUVL) have experienced great improvements. Currently, the application of EUV radiation apart from microlithography comes more and more into focus. Main goal of our research is to utilize the unique interaction between soft x-ray radiation and matter for probing, modifying, and structuring solid surfaces. In this contribution we present a setup capable of generating and focusing EUV radiation. It consists of a table-top laser-produced plasma source. In order to obtain a small focal spot resulting in high EUV fluence, a modified Schwarzschild objective consisting of two spherical mirrors with Mo/Si multilayer coatings is adapted to this source, simultaneously blocking unwanted out-of-band radiation. By demagnified (10x) imaging of the plasma an EUV spot of 5 μm diameter with a maximum energy density of ~0.72 J/cm² is generated (pulse length 8.8 ns). We present first applications of this integrated source and optics system, demonstrating its potential for high-resolution modification and structuring of solid surfaces. As an example, etch rates for PMMA, PC and PTFE depending on EUV fluences were determined, indicating a linear etch behavior for lower energy densities. In order to investigate changes of the chemical composition of PMMA induced by EUV radiation we present FTIR and NEXAFS measurements on irradiated samples. The latter were performed using the laboratory source tuned to the XUV spectral range around the carbon K-edge (λ ~ 4.4 nm) and a flat-field spectrometer. For showing the potential of this setup, first damage tests were performed on grazing incidence gold mirrors. For these thin Gold films, threshold energy densities could be determined, scaling linear with the film thickness.

  9. Nonequilibrium atmospheric pressure plasma jet using a combination of 50 kHz/2 MHz dual-frequency power sources

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Yong-Jie; Yuan, Qiang-Hua; Li, Fei; Wang, Xiao-Min; Yin, Gui-Qin; Dong, Chen-Zhong [Key Laboratory of Atomic and Molecular Physics and Functional Materials of Gansu Province, College of Physics and Electronic Engineering, Northwest Normal University, Lanzhou 730070 (China)

    2013-11-15

    An atmospheric pressure plasma jet is generated by dual sinusoidal wave (50 kHz and 2 MHz). The dual-frequency plasma jet exhibits the advantages of both low frequency and radio frequency plasmas, namely, the long plasma plume and the high electron density. The radio frequency ignition voltage can be reduced significantly by using dual-frequency excitation compared to the conventional radio frequency without the aid of the low frequency excitation source. A larger operating range of α mode discharge can be obtained using dual-frequency excitation which is important to obtain homogeneous and low-temperature plasma. A larger controllable range of the gas temperature of atmospheric pressure plasma could also be obtained using dual-frequency excitation.

  10. Afterglow of a microwave microstrip plasma as an ion source for mass spectrometry

    Science.gov (United States)

    Pfeuffer, Kevin P.; White, Allen; Broekaert, José A. C.; Hieftje, Gary M.

    2015-01-01

    A microwave-induced plasma that was previously used for optical emission spectrometry has been repurposed as an afterglow ion source for mass spectrometry. This compact microwave discharge, termed the microstrip plasma (MSP), is operated at 20-50 W and 2.45 GHz in helium at a flow of 300 mL/min. The primary background ions present in the afterglow are ionized and protonated water clusters. An exponential dilution chamber was used to introduce volatile organic compounds into the MSP afterglow and yielded limits of detection in the 40 ppb to 7 ppm range (v/v). A hydride-generation system was also utilized for detection of volatile hydride-forming elements (arsenic, antimony, tin) in the afterglow and produced limits of detection in the 10-100 ppb range in solution. The MSP afterglow was found capable of desorption and ionization of analyte species directly from a solid substrate, suggesting its use as an ion source for ambient desorption/ionization mass spectrometry.

  11. Effect of Dietary Inulin Source on Piglet Performance, Immunoglobulin Concentration, and Plasma Lipid Profile

    Directory of Open Access Journals (Sweden)

    Grela Eugeniusz R.

    2014-10-01

    Full Text Available The aim of the study was to evaluate the effect of an inulin source (aqueous or aqueous-alcoholic extract, dried chicory root, or dried Jerusalem artichoke tubers on piglet performance, plasma lipid profile, and immunoglobulin concentration. The study was conducted on 534 piglets (44 litters allocated to five nutritional groups: group I (control - fed basal diet, groups II and III receiving basal diet supplemented with 2% of inulin (aqueous and aqueous-alcoholic extract respectively, and groups IV and V -4% additive of dried artichoke or dried chicory respectively. During the trial, piglets’ body weight, feed intake, diarrhoea incidence, and mortality were controlled. Blood samples were collected twice from six animals of each group. In blood plasma, indices of lipid profile and concentrations of IgA, IgG and IgM were measured. The addition of inulin, regardless of its form (extracts or dried plants, significantly improved the rearing indices. In piglets of groups III, IV and V a significant improvement of daily weight gains and feed efficiency was noted. Inulin showed hypolipidemic activity (lowered total cholesterol level and stimulated piglet immune system manifested by elevated IgA and IgG concentrations. Irrespective of the inulin source, a lower mortality rate resulting from the improvement of animal health was noted in all experimental groups.

  12. Diamond-like carbon produced by plasma source ion implantation as a corrosion barrier

    Energy Technology Data Exchange (ETDEWEB)

    Lillard, R.S.; Butt, D.P.; Taylor, T.N.; Walter, K.C.; Nastasi, M.

    1998-03-01

    There currently exists a broad range of applications for which the ability to produce an adherent, hard, wear and, corrosion-resistant coating plays a vital role. These applications include engine components, orthopedic devices, textile manufacturing components, hard disk media, optical coatings, and cutting and machining tools (e.g., punches, taps, scoring dies, and extrusion dies). Ion beam processing can play an important role in all of these technologies. Plasma source ion implantation (PSII) is an emerging technology which has the potential to overcome the limitations of conventional ion implantation by: (1) reducing the time and expense for implanting onto complex shapes and large areas and (2) extending the thickness of the modification zone through ion beam enhanced plasma growth of surface coatings. In PSII, targets are placed directly in a plasma source and then pulse biased to produce a non-line-of-sight process for complex-shaped targets without complex fixturing. If the pulse bias is a relatively high negative potential (20 to 100 kV) ion implantation will result. If however, a low voltage (50--1,200 eV) high duty cycle pulse bias is applied, film deposition from the chamber gas will result, thereby increasing the extent of the surface modification into the 1--10 micron regime. To evaluate the potential for DLC to be used as a corrosion barrier, Electrochemical Impedance Spectroscopy (EIS) and traditional electrochemistry techniques were used to investigate the breakdown mechanism in chloride and nonchloride containing environments. The effect of surface preparation on coating breakdown was also evaluated.

  13. Technical issues in the conduct of large space platform experiments in plasma physics and geoplasma sciences

    Science.gov (United States)

    Szuszczewicz, Edward P.

    1986-01-01

    Large, permanently-manned space platforms can provide exciting opportunities for discoveries in basic plasma and geoplasma sciences. The potential for these discoveries will depend very critically on the properties of the platform, its subsystems, and their abilities to fulfill a spectrum of scientific requirements. With this in mind, the planning of space station research initiatives and the development of attendant platform engineering should allow for the identification of critical science and technology issues that must be clarified far in advance of space station program implementation. An attempt is made to contribute to that process, with a perspective that looks to the development of the space station as a permanently-manned Spaceborne Ionospheric Weather Station. The development of this concept requires a synergism of science and technology which leads to several critical design issues. To explore the identification of these issues, the development of the concept of an Ionospheric Weather Station will necessarily touch upon a number of diverse areas. These areas are discussed.

  14. Information sources in biomedical science and medical journalism: methodological approaches and assessment.

    Science.gov (United States)

    Miranda, Giovanna F; Vercellesi, Luisa; Bruno, Flavia

    2004-09-01

    Throughout the world the public is showing increasing interest in medical and scientific subjects and journalists largely spread this information, with an important impact on knowledge and health. Clearly, therefore, the relationship between the journalist and his sources is delicate: freedom and independence of information depend on the independence and truthfulness of the sources. The new "precision journalism" holds that scientific methods should be applied to journalism, so authoritative sources are a common need for journalists and scientists. We therefore compared the individual classifications and methods of assessing of sources in biomedical science and medical journalism to try to extrapolate scientific methods of evaluation to journalism. In journalism and science terms used to classify sources of information show some similarities, but their meanings are different. In science primary and secondary classes of information, for instance, refer to the levels of processing, but in journalism to the official nature of the source itself. Scientists and journalists must both always consult as many sources as possible and check their authoritativeness, reliability, completeness, up-to-dateness and balance. In journalism, however, there are some important differences and limits: too many sources can sometimes diminish the quality of the information. The sources serve a first filter between the event and the journalist, who is not providing the reader with the fact, but with its projection. Journalists have time constraints and lack the objective criteria for searching, the specific background knowledge, and the expertise to fully assess sources. To assist in understanding the wealth of sources of information in journalism, we have prepared a checklist of items and questions. There are at least four fundamental points that a good journalist, like any scientist, should know: how to find the latest information (the sources), how to assess it (the quality and

  15. Proposal to DOE Basic Energy Sciences: Ultrafast X-ray science facility at the Advanced Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Schoenlein, Robert W.; Falcone, Roger W.; Abela, R.; Alivisatos, A.P.; Belkacem, A.; Berrah, N.; Bozek, J.; Bressler, C.; Cavalleri, A.; Chergui, M.; Glover, T.E.; Heimann, P.A.; Hepburn, J.; Larsson, J.; Lee, R.W.; McCusker, J.; Padmore, H.A.; Pattison, P.; Pratt, S.T.; Shank, C.V.; Wark, J.; Chang, Z.; Robin, D.W.; Schlueter, R.D.; Zholents, A.A.; Zolotorev, M.S.

    2001-12-12

    We propose to develop a true user facility for ultrafast x-ray science at the Advanced Light Source. This facility will be unique in the world, and will fill a critical need for the growing ultrafast x-ray research community. The development of this facility builds upon the expertise from long-standing research efforts in ultrafast x-ray spectroscopy and the development of femtosecond x-ray sources and techniques at both the Lawrence Berkeley National Laboratory and at U.C. Berkeley. In particular, the technical feasibility of a femtosecond x-ray beamline at the ALS has already been demonstrated, and existing ultrafast laser technology will enable such a beamline to operate near the practical limit for femtosecond x-ray flux and brightness from a 3rd generation synchrotron.

  16. Active region plasma outflows as sources of slow/intermediate solar wind

    Science.gov (United States)

    van Driel-Gesztelyi, Lidia M.

    2015-08-01

    L. van Driel-Gesztelyi (1,2,3), D. Baker (1), P. Démoulin (2), Culhane, J.L. (1), M.L. DeRosa (4) C.H. Mandrini (5,6), D.H. Brooks (7), A.N. Fazakerley (1), L.K. Harra (1), L. Zhao (7), T.H. Zurbuchen (7), F.A. Nuevo (5,6), A.M. Vásquez (5,6), G.D. Cristiani (5,6) M. Pick (2)1) UCL/MSSL, UK, (2) Paris Observatory, LESIA, CNRS, France, (3) Konkoly Observatory, Hungary, (4) Lockheed Martin Solar and Astrophysics Laboratory, USA, (5) IAFE, CONICET-UBA, Argentina (6) FCEN, UBA, Argentina (7) Dept. of Atmospheric, Oceanic and Earth Sciences, Univ. of Michigan, USAWe analyse plasma upflows of tens of km/s from the edges of solar active regions discovered by Hinode/EIS and investigate whether or not they become outflows, i.e. find their way into the solar wind. We analyse two magnetic configurations: bipolar and quadrupolar and find that the active region plasma may be directly channeled into the solar wind via interchange reconnection at a high-altitude null point above the active region especially when active regions are located besides coronal holes or in a more complex way via multiple reconnections even from under a closed helmet streamer. We relate the solar observations to in-situ slow/intermediate solar wind streams.

  17. Kilohertz sources of hard x rays and fast ions with femtosecond laser plasmas

    Science.gov (United States)

    Thoss, A.; Richardson, M.; Korn, G.; Faubel, M.; Stiel, H.; Vogt, U.; Elsaesser, T.

    2003-01-01

    We demonstrate a new, stable, kilohertz femtosecond laser plasma source of hard-x-ray continuum and Kα emission that uses a microscopic liquid jet target that is continuous and debris free. Plasmas produced by ultrashort (50-fs) intense laser pulses from a fine (10-30-μm diameter) liquid Ga jet emit bright 9.3- and 10.3-keV Kα and Kβ lines superimposed on a multikilovolt bremmstrahlung continuum. Kilohertz femtosecond x-ray sources will find many applications in time-resolved x-ray diffraction and microscopy studies. As high-intensity lasers become more compact and operate at increasingly high repetition-rates, they require a target configuration that is both repeatable from shot to shot and debris free. Our target provides a pristine, unperturbed filament surface at rates >100 kHz. A number of liquid metal targets are considered. We show the hard-x-ray spectrum described above. The source was generated by a 50-fs-duration, 1-kHz, 2-W, high-intensity Ti:sapphire laser. Using the same technology, we also generate forward-going sub-mega-electron-volt (sub-MeV) protons from a 10-μm liquid water target at 1-kHz repetition rates. Kilohertz sources of high-energy ions will find many applications in time-resolved particle interaction studies and will lead to efficient generation of short-lived isotopes for use in nuclear medicine and other applications. The protons were detected with CR-39 track detectors in both the forward and the backward directions up to energies of ~500 keV. As the intensity of compact high-repetition-rate lasers sources increases, we can expect improvements in the energy, conversion efficiency, and directionality to occur. The effect of these developments is discussed. As compact, high-repetition-rate femtosecond laser technology reaches focused intensities of ~1019 W/cm2, many new applications of high-repetition-rate hard-x-ray and MeV ion sources will become practical.

  18. First beam measurements on the vessel for extraction and source plasma analyses (VESPA) at the Rutherford Appleton Laboratory (RAL)

    Energy Technology Data Exchange (ETDEWEB)

    Lawrie, Scott R., E-mail: scott.lawrie@stfc.ac.uk [ISIS Neutron and Muon Facility, STFC Rutherford Appleton Laboratory, Harwell Oxford, OX11 0QX (United Kingdom); John Adams Institute for Accelerator Science, Department of Physics, University of Oxford (United Kingdom); Faircloth, Daniel C.; Letchford, Alan P.; Perkins, Mike; Whitehead, Mark O.; Wood, Trevor [ISIS Neutron and Muon Facility, STFC Rutherford Appleton Laboratory, Harwell Oxford, OX11 0QX (United Kingdom)

    2015-04-08

    In order to facilitate the testing of advanced H{sup −} ion sources for the ISIS and Front End Test Stand (FETS) facilities at the Rutherford Appleton Laboratory (RAL), a Vessel for Extraction and Source Plasma Analyses (VESPA) has been constructed. This will perform the first detailed plasma measurements on the ISIS Penning-type H{sup −} ion source using emission spectroscopic techniques. In addition, the 30-year-old extraction optics are re-designed from the ground up in order to fully transport the beam. Using multiple beam and plasma diagnostics devices, the ultimate aim is improve H{sup −} production efficiency and subsequent transport for either long-term ISIS user operations or high power FETS requirements. The VESPA will also accommodate and test a new scaled-up Penning H{sup −} source design. This paper details the VESPA design, construction and commissioning, as well as initial beam and spectroscopy results.

  19. A two-stream plasma electron microwave source for high-power millimeter wave generation, phase 1

    Science.gov (United States)

    Guest, Gareth E.; Dandl, Raphael A.

    1989-03-01

    A novel high power millimeter/microwave source is proposed in which one or more pairs of interpenetrating streams of electrons, flowing through a background plasma in a static magnetic field are used to generate a hot-electron plasma that is confined in a mirror-like magnetic field. Energy stored in the anisotropic, hot-electron plasma is then used to amplify pulses of unstable plasma waves to large amplitude by selective deactivation of mechanisms that stabilize the hot-electron plasma during the energy accumulation phase when the density of hot electrons is rapidly increased through the beam-plasma interaction. The Phase 1 program has yielded a design for an experimental arrangement capable of verifying the key aspects of this novel source concept, as well as a theoretical framework for interpreting the empirical Phase 2 results produced by the experimental device and extrapolating those results to evaluate the suitability of the proposed source to meet the requirements of various high power microwave and millimeter wave defense and industrial applications. The experiments will be carried out in a timely and cost-effective way by employing the AMPHED (a CW magetic mirror) experimental facility at Applied Microwave Plasma Concepts (AMPC).

  20. VGI, crowd-sourcing, citizen science and neogeography are not the same!

    CSIR Research Space (South Africa)

    Cooper, AK

    2015-11-01

    Full Text Available ] • Citizen science – The collection and analysis of data relating to the natural world by members of the general public, typically as part of a collaborative project with professional scientists [Oxford] • Neo- – A new or revived form of [Oxford] • Geography... VGI, crowd-sourcing, citizen science and neogeography are not the same! Antony K Cooper Built Environment Unit, CSIR Pretoria, South Africa acooper@csir.co.za United Nations Economic Commission for Africa Expert Group Meeting on Volunteer Geographic...

  1. Plasma properties of a new-type surface wave-sustained plasma source under the conditions of depositing DLC films

    Science.gov (United States)

    Xu, Junqi; Kousaka, Hiroyuki; Umehara, Noritsugu; Diao, Dongfeng

    2006-01-01

    Surface wave-sustained plasma (SWP) is one of the low-pressure, high- density plasma. Applying this technique, diamond-like carbon (DLC) films with excellent characteristics can be prepared by physical vapor deposition (PVD) method. However, the films' application is restricted in some degree, because it is difficult to control the film properties. In this paper, SWP was excited along a conductive rod at a frequency of 2.45 GHz without magnetic fields around the chamber wall. The fundamental theories of plasma diagnostic were presented and plasma properties were studied with a Langmuir probe under the conditions of depositing DLC films by PVD method with a graphite target. Plasma density, electron temperature, plasma potential and target current were measured at difference technique parameters such as gas pressure, microwave power, and so on. As a result, it was proved that plasma properties are greatly affected by microwave power, target voltage and argon gas pressure in chamber. The gas mass flow rate had almost no effect on plasma characters. At the same time, the results indicated that electron density is up to 10 11-10 12cm -3 even at the low pressure of 1 Pa.

  2. Measuring Vapor Intrusion: From Source Science Politics to a Transdisciplinary Approach.

    Science.gov (United States)

    Little, Peter C; Pennell, Kelly G

    2017-01-01

    Investigation of indoor air quality has been on the upswing in recent years. In this article, we focus on how the transport of subsurface vapors into indoor air spaces, a process known as "vapor intrusion," (VI) is defined and addressed. For environmental engineers and physical scientists who specialize in this emerging indoor environmental exposure science, VI is notoriously difficult to characterize, leading the regulatory community to seek improved science-based understandings of VI pathways and exposures. Yet despite the recent growth in VI science and competition between environmental consulting companies, VI studies have largely overlooked the social and political field in which VI problems emerge and are experienced by those at risk. To balance and inform current VI studies, this article explores VI science and policy and develops a critique of what we call "source science politics." Drawing inspiration from the creative synthesis of social and environmental science/engineering perspectives, the article offers a transdisciplinary approach to VI that highlights collaboration with social scientists and impacted communities and cultivates epistemic empathy.

  3. An atmospheric pressure plasma source driven by a train of monopolar high voltage pulses superimposed to a dc voltage

    OpenAIRE

    Stoican, O.S.

    2011-01-01

    Abstract An atmospheric pressure plasma source supplied by an electrical circuit consisting of two voltage sources in parallel connection is reported. One of them is a low-power self-oscillating flyback converter which produces negative voltage pulses with an amplitude of several kilovolts. The high voltage pulses are necessary to ignite an electrical discharge between the electrodes at atmospheric pressure. An additional dc source delivering several hundreds of volts at a few hund...

  4. State of Art in the Science and Technology of Electrical Discharge Light Sources

    Science.gov (United States)

    Zissis, Georges; Rouffet, Jean-Baptiste

    Light is vital for life: Light sources play an indispensable role to daily life of any Human being. Our World cannot be conceived without light. Quality of life, health and, somehow, urban security related with traffic and crime prevention measures depend on light and on its quality. The lighting industry is an important economic factor in Europe, USA and many Asiatic Countries. All in all, lighting is an important socio-economic factor and lighting system development should be an integral part of any Sustainable Development and of any program of improvement of Quality of Life. This presentation provides an overview of the present state of research in the science and technology of light sources. Existing technologies and future challenges for the lighting industry will be presented. To better understanding the light source technology an part of this presentation will be devoted to the physics of light sources.

  5. The Very High Energy source catalog at the ASI Science Data Center

    CERN Document Server

    Carosi, Alessandro; Antonelli, Lucio Angelo; Giommi, Paolo

    2015-01-01

    The increasing number of Very High Energy (VHE) sources discovered by the current generation of Cherenkov telescopes made particularly relevant the creation of a dedicated source catalogs as well as the cross-correlation of VHE and lower energy bands data in a multi-wavelength framework. The "TeGeV Catalog" hosted at the ASI Science Data Center (ASDC) is a catalog of VHE sources detected by ground-based Cherenkov detectors. The TeGeVcat collects all the relevant information publicly available about the observed GeV/TeV sources. The catalog contains also information about public light curves while the available spectral data are included in the ASDC SED Builder tool directly accessible from the TeGeV catalog web page. In this contribution we will report a comprehensive description of the catalog and the related tools.

  6. Commissioning of the upgraded ultracold neutron source at Los Alamos Neutron Science Center

    Science.gov (United States)

    Pattie, Robert; LANL-UCN Team Team

    2016-09-01

    The spallation-driven solid-deuterium ultracold neutron (UCN) source at Los Alamos Neutron Science Center (LANSCE) has provided a facility for precision measurements of fundamental symmetries via the decay observables from neutron beta decay for nearly a decade. In preparation for a new room temperature neutron electric dipole moment (nEDM) experiment and to increase the statistical sensitivity of all experiments using the source an effort to upgrade the existing source has been carried out during 2016. This upgrade includes installing a redesigned cold neutron moderator and with optimized UCN converter geometries, improved coupling and nickel-phosphorus coating of the UCN transport system through the biological shielding, optimization of beam timing structure, and increase of the proton beam current. We will present the result of the commissioning run of the new source.

  7. The very high energy source catalog at the ASI Science Data Center

    Science.gov (United States)

    Carosi, Alessandro; Lucarelli, Fabrizio; Antonelli, Lucio A.; Giommi, Paolo

    2016-07-01

    The increasing number of Very High Energy (VHE) sources discovered by the current generation of Cherenkov telescopes made particularly relevant the creation of a dedicated source catalogs as well as the cross-correlation of VHE and lower energy bands data in a multi-wavelength framework. The "TeGeV Catalog" hosted at the ASI Science Data Center (ASDC) is a catalog of VHE sources detected by ground-based Cherenkov detectors. The TeGeVcat collects all the relevant information publicly available about the observed GeV/TeV sources. The catalog contains also information about public light curves while the available spectral data are included in the ASDC SED Builder tool directly accessible from the TeGeV catalogue web page. In this contribution we will report a comprehensive description of the catalog and the related tools.

  8. An oil-free compact X-pinch plasma radiation source: Design and radiation performance

    Science.gov (United States)

    Shapovalov, Roman V.; Spielman, Rick B.; Imel, George R.

    2017-06-01

    This paper describes a new, high-current, X-pinch radiation source recently developed and tested at Idaho State University. Our design is based on two linear transformer driver (LTD) bricks arranged in side-by-side geometry and directly coupled with an X-pinch load. The salient features of our 2-LTD-bricks are its simplicity, compactness, and portability: there is no oil, no water, and no SF6. It can be easily relocated to any place where a compact X-pinch radiation source is wanted. The driver can store up to 2.8 kJ of initial energy and can deliver more than 200-kA peak-current with less than 200-ns, 10%-90%, rise time into a short-circuit load. When the driver is coupled with an X-pinch load, it generates a very fast and bright radiation pulse. Source size measurements indicate that this radiation originates from a very small dense plasma, known as a "hot spot."

  9. Free and Open Source Software for Geospatial in the field of planetary science

    Science.gov (United States)

    Frigeri, A.

    2012-12-01

    Information technology applied to geospatial analyses has spread quickly in the last ten years. The availability of OpenData and data from collaborative mapping projects increased the interest on tools, procedures and methods to handle spatially-related information. Free Open Source Software projects devoted to geospatial data handling are gaining a good success as the use of interoperable formats and protocols allow the user to choose what pipeline of tools and libraries is needed to solve a particular task, adapting the software scene to his specific problem. In particular, the Free Open Source model of development mimics the scientific method very well, and researchers should be naturally encouraged to take part to the development process of these software projects, as this represent a very agile way to interact among several institutions. When it comes to planetary sciences, geospatial Free Open Source Software is gaining a key role in projects that commonly involve different subjects in an international scenario. Very popular software suites for processing scientific mission data (for example, ISIS) and for navigation/planning (SPICE) are being distributed along with the source code and the interaction between user and developer is often very strict, creating a continuum between these two figures. A very widely spread library for handling geospatial data (GDAL) has started to support planetary data from the Planetary Data System, and recent contributions enabled the support to other popular data formats used in planetary science, as the Vicar one. The use of Geographic Information System in planetary science is now diffused, and Free Open Source GIS, open GIS formats and network protocols allow to extend existing tools and methods developed to solve Earth based problems, also to the case of the study of solar system bodies. A day in the working life of a researcher using Free Open Source Software for geospatial will be presented, as well as benefits and

  10. Reduction of the electrostatic coupling in a large-area internal inductively coupled plasma source using a multicusp magnetic field

    Science.gov (United States)

    Lee, Y. J.; Kim, K. N.; Yeom, G. Y.; Lieberman, M. A.

    2004-09-01

    A large area (1020mm×830mm) inductively coupled plasma (ICP) source has been developed using an internal-type linear antenna with permanent magnets forming a multicusp magnetic field. The large rf antenna voltages, which cause the electrostatic coupling between the antenna and the plasma in a large area internal-type linear-antenna ICP source, were decreased significantly by applying the magnetic field near and parallel to the antenna. Through the application of the magnetic field, an approximately 20% higher plasma density, with a value of close to 1.0×1011cm-3 at a rf power of 2000W, and about three times higher photoresist etch rates were observed, while maintaining the plasma nonuniformity at less than 9%.

  11. Comparative study of non-thermal atmospheric pressure discharge plasmas for life science applications

    Science.gov (United States)

    Koga, Kazunori; Katayama, Ryu; Sarinont, Thapanut; Seo, Hyunwoong; Itagaki, Naho; Attri, Pankaj; Leal-Quiros, Edbertho; Tanaka, Akiyo; Shiratani, Masaharu

    2016-09-01

    We are comparing several non-thermal atmospheric pressure discharge plasmas for life science applications. Here we measured discharge period dependence of pH value and 750 nm absorbance of KI-starch solution of deionized water after plasma irradiation with two discharge devices; a dielectric barrier discharge (DBD) jet device and a scalable DBD device. The pH and the absorbance of KI-starch solution are useful indicator of their oxidizability. We have obtained a map of the absorbance and proton concentration [H+] which is deduced from pH value. For the scalable DBD, the range of the absorbance is between 0.7 and 1.3 and that of [H+] is between 10-7 and 10-5 mol/L. For the DBD jet, the range of the absorbance and [H+] are 2.0-3.2 and 10-4-10-3 mol/L, respectively. Measured data for both devices shows same tendency in the map, while the range of values for the scalable DBD is smaller than that for the DBD jet. The results indicate the oxidazability for the scalable DBD is much weaker than that for the DBD jet.

  12. Computational Plasma Physics at the Bleeding Edge: Simulating Kinetic Turbulence Dynamics in Fusion Energy Sciences

    Science.gov (United States)

    Tang, William

    2013-04-01

    Advanced computing is generally recognized to be an increasingly vital tool for accelerating progress in scientific research in the 21st Century. The imperative is to translate the combination of the rapid advances in super-computing power together with the emergence of effective new algorithms and computational methodologies to help enable corresponding increases in the physics fidelity and the performance of the scientific codes used to model complex physical systems. If properly validated against experimental measurements and verified with mathematical tests and computational benchmarks, these codes can provide more reliable predictive capability for the behavior of complex systems, including fusion energy relevant high temperature plasmas. The magnetic fusion energy research community has made excellent progress in developing advanced codes for which computer run-time and problem size scale very well with the number of processors on massively parallel supercomputers. A good example is the effective usage of the full power of modern leadership class computational platforms from the terascale to the petascale and beyond to produce nonlinear particle-in-cell simulations which have accelerated progress in understanding the nature of plasma turbulence in magnetically-confined high temperature plasmas. Illustrative results provide great encouragement for being able to include increasingly realistic dynamics in extreme-scale computing campaigns to enable predictive simulations with unprecedented physics fidelity. Some illustrative examples will be presented of the algorithmic progress from the magnetic fusion energy sciences area in dealing with low memory per core extreme scale computing challenges for the current top 3 supercomputers worldwide. These include advanced CPU systems (such as the IBM-Blue-Gene-Q system and the Fujitsu K Machine) as well as the GPU-CPU hybrid system (Titan).

  13. Ultrafast X-ray Science at the Sub-Picosecond Pulse Source

    Energy Technology Data Exchange (ETDEWEB)

    Gaffney, Kelly J.; /SLAC, SSRL

    2005-09-30

    The ultrafast, high brightness x-ray free electron laser (XFEL) sources of the future have the potential to revolutionize the study of time dependent phenomena in the natural sciences. These linear accelerator (linac) sources will generate femtosecond (fs) x-ray pulses with peak flux comparable to conventional lasers, and far exceeding all other x-ray sources. The Stanford Linear Accelerator Center (SLAC) has pioneered the development of linac science and technology for decades, and since 2000 SLAC and the Stanford Synchrotron Radiation Laboratory (SSRL) have focused on the development of linac based ultrafast electron and x-ray sources. This development effort has led to the creation of a new x-ray source, called the Sub-Picosecond Pulse Source (SPPS), which became operational in 2003 [1]. The SPPS represents the first step toward the world's first hard x-ray free electron laser (XFEL), the Linac Coherent Light Source (LCLS), due to begin operation at SLAC in 2009. The SPPS relies on the same linac-based acceleration and electron bunch compression schemes that will be used at the LCLS to generate ultrashort, ultrahigh peak brightness electron bunches [2]. This involves creating an energy chirp on the electron bunch during acceleration and subsequent compression of the bunch in a series of energy-dispersive magnetic chicanes to create 80 fs electron pulses. The SPPS has provided an excellent opportunity to demonstrate the viability of these electron bunch compression schemes and to pursue goals relevant to the utilization and validation of XFEL light sources.

  14. Data Science: History repeated? - The heritage of the Free and Open Source GIS community

    Science.gov (United States)

    Löwe, Peter; Neteler, Markus

    2014-05-01

    Data Science is described as the process of knowledge extraction from large data sets by means of scientific methods. The discipline draws heavily from techniques and theories from many fields, which are jointly used to furthermore develop information retrieval on structured or unstructured very large datasets. While the term Data Science was already coined in 1960, the current perception of this field places is still in the first section of the hype cycle according to Gartner, being well en route from the technology trigger stage to the peak of inflated expectations. In our view the future development of Data Science could benefit from the analysis of experiences from related evolutionary processes. One predecessor is the area of Geographic Information Systems (GIS). The intrinsic scope of GIS is the integration and storage of spatial information from often heterogeneous sources, data analysis, sharing of reconstructed or aggregated results in visual form or via data transfer. GIS is successfully applied to process and analyse spatially referenced content in a wide and still expanding range of science areas, spanning from human and social sciences like archeology, politics and architecture to environmental and geoscientific applications, even including planetology. This paper presents proven patterns for innovation and organisation derived from the evolution of GIS, which can be ported to Data Science. Within the GIS landscape, three strategic interacting tiers can be denoted: i) Standardisation, ii) applications based on closed-source software, without the option of access to and analysis of the implemented algorithms, and iii) Free and Open Source Software (FOSS) based on freely accessible program code enabling analysis, education and ,improvement by everyone. This paper focuses on patterns gained from the synthesis of three decades of FOSS development. We identified best-practices which evolved from long term FOSS projects, describe the role of community

  15. Soft x-ray spectromicroscopy development for materials science at the Advanced Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Warwick, T.; Padmore, H. [Lawrence Berkeley National Lab., CA (United States); Ade, H. [North Carolina State Univ., Raleigh, NC (United States); Hitchcock, A.P. [McMaster Univ., Hamilton, Ontario (Canada); Rightor, E.G. [Dow Texas Polymer Center, Freeport, TX (United States); Tonner, B.P. [Univ. of Wisconsin, Milwaukee, WI (United States)

    1996-08-01

    Several third generation synchrotron radiation facilities are now operational and the high brightness of these photon sources offers new opportunities for x-ray microscopy. Well developed synchrotron radiation spectroscopy techniques are being applied in new instruments capable of imaging the surface of a material with a spatial resolution smaller than one micron. There are two aspects to this. One is to further the field of surface science by exploring the effects of spatial variations across a surface on a scale not previously accessible to x-ray measurements. The other is to open up new analytical techniques in materials science using x-rays, on a spatial scale comparable to that of the processes or devices to be studied. The development of the spectromicroscopy program at the Advanced Light Source will employ a variety of instruments, some are already operational. Their development and use will be discussed, and recent results will be presented to illustrate their capabilities.

  16. 电感耦合等离子体光源的研究及应用前景%Research and Application Prospect of Inductively Coupled Plasma Source

    Institute of Scientific and Technical Information of China (English)

    彭雪梅; 刘永文; 富中华

    2011-01-01

    电感耦合等离子体光源(ICP光源)是一种很好的原子化源、离子化源和激发源,常被用作原子发射光谱分析的激发光源,在环境科学、材料科学、生命科学、地质分析、冶金分析等领域有着广泛的应用。文章对ICP光源的发明历史、结构组成、各项性能、工作原理以及日常维护的注意事项进行了分别阐述,并对ICP光源在质谱技术(ICP-MS)、原子荧光光谱技术(ICP-AFS)、原子吸收光谱技术(ICP-AAS)、气相色谱技术(ICP-AES-GC)、液相色谱技术(ICP-AES-HPLC)等领域的应用前景作了简要概述。%Inductively coupled plasma source(ICP),as a good atomization source,ionization source and the excitation source,is often used as atomic emission spectral analysis of excitation light source.It has a wide range of applications in environmental science,material science,life science,geological analysis,metallurgical analysis and other fields.This paper elaborated ICP source structure,the influencing factors on the performance and operating principle,separately.Finally,the daily maintenance measures about ICP were summarized and its applications were prospected,such as ICP-MS,ICP-AFS,ICP-AAS,ICP-AES –GC and ICP-AES-HPLC.

  17. Ion Behavior and Gas Mixing in electron cyclotron resonance plasmas as sources of highly charged ions (concept

    OpenAIRE

    Melin, G.; Drentje, A. G.; Girard, A; Hitz, D.

    1999-01-01

    Abstract: An ECR ion source is basically an ECR heated plasma confinement machine, with hot electrons and cold ions. The main parameters of the ion population have been analyzed, including temperature, losses, and confinement time. The "gas mixing" effect has been studied in this context. An expression is derived for determining the ion temperature from the values of all extracted ion currents. One aim is to study the ion temperature behavior in argon plasmas without and with mixing different...

  18. Hundred joules plasma focus device as a potential pulsed source for in vitro cancer cell irradiation

    Science.gov (United States)

    Jain, J.; Moreno, J.; Andaur, R.; Armisen, R.; Morales, D.; Marcelain, K.; Avaria, G.; Bora, B.; Davis, S.; Pavez, C.; Soto, L.

    2017-08-01

    Plasma focus devices may arise as useful source to perform experiments aimed to study the effects of pulsed radiation on human cells in vitro. In the present work, a table top hundred joules plasma focus device, namely "PF-400J", was adapted to irradiate colorectal cancer cell line, DLD-1. For pulsed x-rays, the doses (energy absorbed per unit mass, measured in Gy) were measured using thermoluminescence detectors (TLD-100 dosimeters). The neutron fluence and the average energy were used to estimate the pulsed neutron doses. Fifty pulses of x-rays (0.12 Gy) and fifty pulses of neutrons (3.5 μGy) were used to irradiate the cancer cells. Irradiation-induced DNA damage and cell death were assessed at different time points after irradiation. Cell death was observed using pulsed neutron irradiation, at ultralow doses. Our results indicate that the PF-400J can be used for in vitro assessment of the effect of pulsed radiation in cancer cell research.

  19. Numerical simulation of low-temperature helium plasma source for biomedical applications

    Science.gov (United States)

    Bekasov, Vladimir; Zamchy, Roman; Kudryavtsev, Anatoly

    2016-09-01

    Numerical simulation of low-temperature helium plasma for biomedical applications was conducted. The plasma source is presented as a rod electrode located above the grounded plate. Helium acts as a working gas, which is supplied to the discharge through a quartz tube surrounding the rod electrode. An AC voltage with a frequency of 13 kHz and amplitude of up to 3 kV is applied to the electrode. Distance between rod tip and plate varies from 1 to 8 centimeters. Helium blow rate is considered in the range from 1 to 10 m / s. For a description of the discharge, in this paper, two-dimensional extended fluid model was presented. It consists of the continuity equations for calculating the concentration of particles, the energy balance equation for finding the electron temperature and the Poisson equation for electric fields. To calculate the velocity of neutral particles Navier-Stokes equations was solved, and thermal conductivity equation was solved for calculating the heating of the neutral gas. The work was supported by Saint Petersburg State University (Grant ?11.37.212.2016).

  20. Laser-produced plasma He-alpha source for pulse radiography

    Institute of Scientific and Technical Information of China (English)

    Ruirong Wang; Weimin Chen; Chusheng Mao; Jiaqin Dong; Sizu Fu

    2009-01-01

    Through the use of time and space integrated kiloelectronvolt (keV) spectroscopy, we investigate the thermal emission of plasma, which produces strong line emission from the titanium K shell (He-α at 4.7 keV and H-α at 4.9 keV), created by laser. In order to optimize the conversion efficiency enhancement on titanium foils, the experiment is conducted under a variety of laser-driven intensity conditions. The X-ray emission intensity at 4.7 keV is measured and compared with prediction. The experimental result demonstrates that the solid Ti target laser-produced plasma (LPP) source has X-ray emission at 4.7 keV, which are all generated from electronic transitions in Ti ions at pulse width of 2.1 ns or 30 ps, the crudely evaluated He-α X-ray intensity appears to slightly increase with laser intensity enhancement, and the pre-pulse effect increases the conversion efficiency of the He-α X-ray. In addition, a 90-μm-thick Ti foil as a filter is used to transmit He-α X-ray at near 4.7 keV, creating a quasi-monochromatic transmission and greatly reducing thc lower- and higher-energy background.

  1. Radiography using a dense plasma focus device as a source of pulsed X-rays

    Science.gov (United States)

    Herrera, Julio; Castillo, Fermín; Gamboa, Isabel; Rangel, José

    2007-11-01

    Soft and hard X-ray emissions have been studied in the FN-II, which is a small dense plasma focus machine (5 kJ), operating at the Instituto de Ciencias Nucleares, UNAM, using aluminum filtered pin-hole cameras. Their angular distribution has been measured using TLD-200 dosimeters [1]. Their temporal evolution has been observed by means of a PIN diode, and scinltillators coupled to photomultipliers outside the discharge chamber. The X rays source can be concentrated by placing a needle on the end of the electrode. X-rays crossing across a 300 micron aluminum window, through the axis of the machine, can be used to obtain high contrast radiographs, with an average dose of 0.4 mGy per shot. In contrast, the average dose with a hollow cathode is 0.2 mGy per shot. This work is partially supported by grant IN105705 de la DGAPA-UNAM. [1] F. Castillo, J.J.E. Herrera, J. Rangel, I. Gamboa, G. Espinosa y J.I. Golzarri ``Angular Distribution of fusion products and X-rays emitted by a small dense plasma focus machine'' Journal of Applied Physics 101 013303-1-7 (2007).

  2. Simulation of the Partially Ionized Reacting Plasma Flow in a Negative Hydrogen Ion Source

    Science.gov (United States)

    Gatsonis, Nikolaos; Averkin, Sergey; Olson, Lynn

    2012-10-01

    A High Pressure Discharge Negative Ion Source (HPDNIS) operating on hydrogen is been under investigation. The Negative Ion Production (NIP) section of the HPDNIS attaches to the 10-100 Torr RF-discharge chamber with a micronozzle and ends with a grid that extracts the negative ion beam. The partially ionized and reacting plasma flow in the NIP section is simulated using an unstructured three-dimensional Direct Simulation Monte Carlo (U3DSMC) code. The NIP section contains a low-pressure plasma that includes H2, vibrationally-rotationally excited H2^*, negative hydrogen atoms H^-, and electrons. Primary reactions in the NIP section are dissociate attachment, H2^*+e->H^0+H^-and electron collisional detachment, e+H^-->H+2e. The U3DSMC computational domain includes the entrance to the NIP nozzle and the extraction grid at the exit. The flow parameters at the entrance are based on conditions in the RF-discharge chamber and are implemented in U3DSMC using a Kinetic-Moment subsonic boundary conditions method. The rotational and vibrational degrees of freedom in U3DSMC are implemented using the Larsen-Borgnakke model. Chemical reactions are implemented in U3DSMC using the Quantum-Kinetic model. Simulations cover the regime of operation of the HPDNIS and examine the flow characteristics inside the NIP section.

  3. Intense positron beam as a source for production of electron-positron plasma

    Science.gov (United States)

    Stoneking, M. R.; Horn-Stanja, J.; Stenson, E. V.; Pedersen, T. Sunn; Saitoh, H.; Hergenhahn, U.; Niemann, H.; Paschkowski, N.; Hugenschmidt, C.; Piochacz, C.

    2016-10-01

    We aim to produce magnetically confined, short Debye length electron-positron plasma and test predicted properties for such systems. A first challenge is obtaining large numbers of positrons; a table-top experiment (system size 5 cm) with a temperature less than 5 eV requires about 1010 positrons to have more than 10 Debye lengths in the system. The NEPOMUC facility at the FRM II research reactor in Germany is one of the world's most intense positron sources. We report on characterization (using a retarding field energy analyzer with magnetic field gradient) of the NEPOMUC beam as delivered to the open beam port at various beam energies and in both the re-moderated and primary beam configurations in order to design optimal trapping (and accumulation) schemes for production of electron-positron plasma. The intensity of the re-moderated (primary) beam is in the range 2 -3 x 107 /s (1 - 5 x 108 /s). The re-moderated beam is currently the most promising for direct injection and confinement experiments; it has a parallel energy spread of 15 - 35% and the transverse energy spread is 6 - 15% of the parallel energy. We report on the implications for injection and trapping in a dipole magnetic field as well as plans for beam development, in situ re-moderation, and accumulation. We also report results demonstrating a difference in phosphor luminescent response to low energy positrons versus electrons.

  4. Laser-plasma sourced, temperature dependent, VUV spectrophotometer using dispersive analysis

    Science.gov (United States)

    French, R. H.

    1990-04-01

    We have developed a vacuum ultraviolet spectrophotometer with wide energy and temperature range coverage, utilizing a laser-plasma light source (LPLS), CO2-laser sample heating and time-resolved dispersive analysis. Reflection and transmission spectra can be taken from 1.7 to 40eV (31-700nm) on samples at 15-1800K with a time resolution of 20-400ns. These capabilities permit the study of the temperature dependence of the electronic structure, encompassing the effects of thermal lattice expansion and electron-phonon interaction, and changes in the electronic structure associated with equilibrium and metastable phase transitions and stress relaxation. The LPLS utilizes a samarium laser-plasma created by a Q-switched Nd:YAG laser (500mJ/pulse) to produce high brightness, stable, continuum radiation. The spectrophotometer is of a single beam design using calibrated iridium reference mirrors. White light is imaged off the sample in to the entrance slit of a l-m polychromator. The resolution is 0.1 to 0.3nm. The dispersed light is incident on a focal plane phosphor, fiber-optic-coupled to an image-intensified reticon detector. For spectroscopy between 300 and 1800K, the samples are heated in situ with a 150 Watt CO2 laser. The signal to noise ratio in the VUV, for samples at 1800 K, is excellent. From 300 K to 15 K samples are cooled using a He cryostat.

  5. Environmental friendly high efficient light source. Plasma lamp. 2006 annual report

    Energy Technology Data Exchange (ETDEWEB)

    Courret, G.

    2006-07-01

    This annual report for 2006 for the Swiss Federal Office of Energy (SFOE) reports on work being done on the development of a high-efficiency source of light based on the light emission of a plasma. The report presents a review of work done in 2006, including thermodynamics and assessment of the efficiency of the magnetron, tests with small bulbs, study of the standing wave ratio (microwave fluxes) and the development of a new coupling system to allow ignition in very small bulbs. Also, knowledge on the fillings of the bulb and induced effects of the modulator were gained. The development of a second generation of modulator to obtain higher efficiency at lower power is noted.

  6. A desktop extreme ultraviolet microscope based on a compact laser-plasma light source

    Science.gov (United States)

    Wachulak, P. W.; Torrisi, A.; Bartnik, A.; Węgrzyński, Ł.; Fok, T.; Fiedorowicz, H.

    2017-01-01

    A compact, desktop size microscope, based on laser-plasma source and equipped with reflective condenser and diffractive Fresnel zone plate objective, operating in the extreme ultraviolet (EUV) region at the wavelength of 13.8 nm, was developed. The microscope is capable of capturing magnified images of objects with 95-nm full-pitch spatial resolution (48 nm 25-75% KE) and exposure time as low as a few seconds, combining reasonable acquisition conditions with stand-alone desktop footprint. Such EUV microscope can be regarded as a complementary imaging tool to already existing, well-established ones. Details about the microscope, characterization, resolution estimation and real sample images are presented and discussed.

  7. Low Energy Plasma Focus as an Intense X-ray Source for Radiography

    Institute of Scientific and Technical Information of China (English)

    S. Hussain; M. Zakaullah; Shujaat Ali; A. Waheed

    2004-01-01

    Study on X-ray emission from a low energy (1.8 k J) plasma focus device powered by a 9 μF capacitor bank, charged at 20 kV and giving peak discharge current of about 175 kA by using a lead-inserted copper-tapered anode is reported. The X-ray yield in different energy windows is measured as a function of hydrogen filling pressure. The maximum yield in 4π-geometry is found to be (27.3±1.1) J and corresponding wall plug efficiency for X-ray generation is 1.52 ±0.06%. X-ray emission, presumably due to bombarding activity of electrons in current sheath at the anode tip was dominant, which is confirmed by the pinhole images. The feasibility of the device as an intense X-ray source for radiography is demonstrated.

  8. Calibration Of A KrF Laser-Plasma Source For X-Ray Microscopy Applications

    Science.gov (United States)

    Turcu, I. C. E.; O'Neill, F.; Zammit, U.; Al-Hadithi, Y.; Eason, R. W.; Rogayski, A. M.; Hills, C. P. B.; Michette, A. G.

    1988-02-01

    Plasma X-ray sources for biological microscopy in the water-window have been produced by focusing tige 200 3, 50 ns Sprit q KrF laser onto carbon targets at irradiance between 2.2 x 10" W/cm4 and 3.7 x 10i3W/cm. Absolute measurements of X-ray production have been made using a calibrated, vacuum X-ray diode detector. A peak conversion efficiency . 10% is measured from KrF laseri)Tight tcto wate-window X-rays at 280 eV < hv < 530 eV for a target irradiance . 1 x x 10 W/cm'. Some measurements with gold and tungsten targets give conversion efficiencies 2$25% at a similar laser irradiance.

  9. Misconceptions and biases in German students' perception of multiple energy sources: implications for science education

    Science.gov (United States)

    Lee, Roh Pin

    2016-04-01

    Misconceptions and biases in energy perception could influence people's support for developments integral to the success of restructuring a nation's energy system. Science education, in equipping young adults with the cognitive skills and knowledge necessary to navigate in the confusing energy environment, could play a key role in paving the way for informed decision-making. This study examined German students' knowledge of the contribution of diverse energy sources to their nation's energy mix as well as their affective energy responses so as to identify implications for science education. Specifically, the study investigated whether and to what extent students hold mistaken beliefs about the role of multiple energy sources in their nation's energy mix, and assessed how misconceptions could act as self-generated reference points to underpin support/resistance of proposed developments. An in-depth analysis of spontaneous affective associations with five key energy sources also enabled the identification of underlying concerns driving people's energy responses and facilitated an examination of how affective perception, in acting as a heuristic, could lead to biases in energy judgment and decision-making. Finally, subgroup analysis differentiated by education and gender supported insights into a 'two culture' effect on energy perception and the challenge it poses to science education.

  10. Helicon Discharge with Selectable Nitrogen Reactive Species Production as a Plasma Source for III-group Nitrides Growth by MBE

    Science.gov (United States)

    Biloiu, Costel; Doss, Forest; Scime, Earl

    2004-11-01

    Plasma assisted molecular beam epitaxy (PAMBE) of III-N materials is a potential alternative to MOCVD for fabrication of high quality wide band gap semiconductor devices. In the helicon plasma source, it may be possible to control the population of specific reactive nitrogen species by modification of the electron energy distribution function through the resonant wave-particle interaction arising from electrons traveling at same velocity as the helicon wave phase velocity. We report preliminary results on control of reactive nitrogen species performed in a steady state, high density, helicon plasma source CHEWIE (Compact HElicon Waves and Instabilities Experiment). The helicon vacuum chamber is a 12 cm long, Pyrex tube, 6 cm in diameter, connected to a stainless steel diffusion chamber. RF power of up to 1.0 kW over a frequency range of 3-28 MHz is used to create the steady state plasma. A 7 cm long, half wave, m = +1, helical antenna couples the rf energy into the plasma. A single solenoidal magnetic field coil surrounds the source and is capable of generating axial magnetic fields up to 600 G. Optical emission spectroscopy investigations show that under certain conditions, the decay from the long lived A^3Σ_u^+ state dominates the emission spectrum of the plasma.

  11. kHz femtosecond laser-plasma hard X-ray and fast ion source

    Science.gov (United States)

    Thoss, A.; Korn, G.; Richardson, M. C.; Faubel, M.; Stiel, H.; Voigt, U.; Siders, C. W.; Elsaesser, T.

    2002-04-01

    We describe the first demonstration of a new stable, kHz femtosecond laser-plasma source of hard x-ray continuum and Kα emission using a thin liquid metallic jet target. kHz femtosecond x-ray sources will find many applications in time-resolved x-ray diffraction and microscopy studies. As high intensity lasers become more compact and operate at increasingly high repetition-rates, they require a target configuration that is both repeatable from shot-to-shot and is debris-free. We have solved this requirement with the use of a fine (10-30 μm diameter) liquid metal jet target that provides a pristine, unperturbed filament surface at rates >100 kHz. A number of liquid metal targets are considered. We will show hard x-ray spectra recorded from liquid Ga targets that show the generation of the 9.3 keV and 10.3 keV, Kα and Kβ lines superimposed on a multi-keV Bremsstrahlung continuum. This source was generated by a 50fs duration, 1 kHz, 2W, high intensity Ti:Sapphire laser. We will discuss the extension of this source to higher powers and higher repetition rates, providing harder x-ray emission, with the incorporation of pulse-shaping and other techniques to enhance the x-ray conversion efficiency. Using the same liquid target technology, we have also demonstrated the generation of forward-going sub-MeV protons from a 10 μm liquid water target at 1 kHz repetition rates. kHz sources of high energy ions will find many applications in time-resolved particle interaction studies, as well as lead to the efficient generation of short-lived isotopes for use in nuclear medicine and other applications. The protons were detected with CR-39 track detectors both in the forward and backward directions up to energies of ~500 keV. As the intensity of compact high repetition-rate lasers sources increase, we can expect improvements in the energy, conversion efficiency and directionality to occur. The impact of these developments on a number of fields will be discussed. As compact

  12. Online tuning of impedance matching circuit for long pulse inductively coupled plasma source operation--an alternate approach.

    Science.gov (United States)

    Sudhir, Dass; Bandyopadhyay, M; Kraus, W; Gahlaut, A; Bansal, G; Chakraborty, A

    2014-01-01

    Impedance matching circuit between radio frequency (RF) generator and the plasma load, placed between them, determines the RF power transfer from RF generator to the plasma load. The impedance of plasma load depends on the plasma parameters through skin depth and plasma conductivity or resistivity. Therefore, for long pulse operation of inductively coupled plasmas, particularly for high power (∼100 kW or more) where plasma load condition may vary due to different reasons (e.g., pressure, power, and thermal), online tuning of impedance matching circuit is necessary through feedback. In fusion grade ion source operation, such online methodology through feedback is not present but offline remote tuning by adjusting the matching circuit capacitors and tuning the driving frequency of the RF generator between the ion source operation pulses is envisaged. The present model is an approach for remote impedance tuning methodology for long pulse operation and corresponding online impedance matching algorithm based on RF coil antenna current measurement or coil antenna calorimetric measurement may be useful in this regard.

  13. Next-Generation Photon Sources for Grand Challenges in Science and Energy

    Energy Technology Data Exchange (ETDEWEB)

    None

    2009-05-01

    The next generation of sustainable energy technologies will revolve around transformational new materials and chemical processes that convert energy efficiently among photons, electrons, and chemical bonds. New materials that tap sunlight, store electricity, or make fuel from splitting water or recycling carbon dioxide will need to be much smarter and more functional than today's commodity-based energy materials. To control and catalyze chemical reactions or to convert a solar photon to an electron requires coordination of multiple steps, each carried out by customized materials and interfaces with designed nanoscale structures. Such advanced materials are not found in nature the way we find fossil fuels; they must be designed and fabricated to exacting standards, using principles revealed by basic science. Success in this endeavor requires probing, and ultimately controlling, the interactions among photons, electrons, and chemical bonds on their natural length and time scales. Control science - the application of knowledge at the frontier of science to control phenomena and create new functionality - realized through the next generation of ultraviolet and X-ray photon sources, has the potential to be transformational for the life sciences and information technology, as well as for sustainable energy. Current synchrotron-based light sources have revolutionized macromolecular crystallography. The insights thus obtained are largely in the domain of static structure. The opportunity is for next generation light sources to extend these insights to the control of dynamic phenomena through ultrafast pump-probe experiments, time-resolved coherent imaging, and high-resolution spectroscopic imaging. Similarly, control of spin and charge degrees of freedom in complex functional materials has the potential not only to reveal the fundamental mechanisms of high-temperature superconductivity, but also to lay the foundation for future generations of information science. This

  14. Simplification of the Plasma Load of Negative-Pulse-Bias Source Used in Arc Ion Plating

    Institute of Scientific and Technical Information of China (English)

    Dong QI; Ninghui WANG; Guoqiang LIN; Zhenfeng DING

    2003-01-01

    Based on the voltage and current fluctuating phenomenon in the arc plasma load under the negative-pulse-bias, usingthe plasma physics theory and analysis of computer simulation expatiates that the nature of plasma load in vacuumarc plasma is a capacitance

  15. Characteristics of silicon nitride deposited by VHF (162 MHz)-plasma enhanced chemical vapor deposition using a multi-tile push-pull plasma source

    Science.gov (United States)

    Kim, Ki Seok; Sirse, Nishant; Kim, Ki Hyun; Rogers Ellingboe, Albert; Kim, Kyong Nam; Yeom, Geun Young

    2016-10-01

    To prevent moisture and oxygen permeation into flexible organic electronic devices formed on substrates, the deposition of an inorganic diffusion barrier material such as SiN x is important for thin film encapsulation. In this study, by a very high frequency (162 MHz) plasma-enhanced chemical vapor deposition (VHF-PECVD) using a multi-tile push-pull plasma source, SiN x layers were deposited with a gas mixture of NH3/SiH4 with/without N2 and the characteristics of the plasma and the deposited SiN x film as the thin film barrier were investigated. Compared to a lower frequency (60 MHz) plasma, the VHF (162 MHz) multi-tile push-pull plasma showed a lower electron temperature, a higher vibrational temperature, and higher N2 dissociation for an N2 plasma. When a SiN x layer was deposited with a mixture of NH3/SiH4 with N2 at a low temperature of 100 °C, a stoichiometric amorphous Si3N4 layer with very low Si-H bonding could be deposited. The 300 nm thick SiN x film exhibited a low water vapor transmission rate of 1.18  ×  10-4 g (m2 · d)-1, in addition to an optical transmittance of higher than 90%.

  16. Study of the feasibility of distributed cathodic arc as a plasma source for development of the technology for plasma separation of SNF and radioactive wastes

    Energy Technology Data Exchange (ETDEWEB)

    Amirov, R. Kh.; Vorona, N. A.; Gavrikov, A. V.; Liziakin, G. D.; Polistchook, V. P.; Samoylov, I. S.; Smirnov, V. P.; Usmanov, R. A., E-mail: ravus46@yandex.ru; Yartsev, I. M. [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation)

    2015-12-15

    One of the key problems in the development of plasma separation technology is designing a plasma source which uses condensed spent nuclear fuel (SNF) or nuclear wastes as a raw material. This paper covers the experimental study of the evaporation and ionization of model materials (gadolinium, niobium oxide, and titanium oxide). For these purposes, a vacuum arc with a heated cathode on the studied material was initiated and its parameters in different regimes were studied. During the experiment, the cathode temperature, arc current, arc voltage, and plasma radiation spectra were measured, and also probe measurements were carried out. It was found that the increase in the cathode heating power leads to the decrease in the arc voltage (to 3 V). This fact makes it possible to reduce the electron energy and achieve singly ionized plasma with a high degree of ionization to fulfill one of the requirements for plasma separation of SNF. This finding is supported by the analysis of the plasma radiation spectrum and the results of the probe diagnostics.

  17. Influence of microwave driver coupling design on plasma density at Testbench for Ion sources Plasma Studies, a 2.45 GHz Electron Cyclotron Resonance Plasma Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Megía-Macías, A.; Vizcaíno-de-Julián, A. [E.S.S. Bilbao, Edificio Cosimet, Landabarri 2, 48940-Leioa, Vizcaya (Spain); Cortázar, O. D., E-mail: dcortazar@essbilbao.org [E.S.S. Bilbao, Edificio Cosimet, Landabarri 2, 48940-Leioa, Vizcaya (Spain); Universidad de Castilla-La Mancha, ETSII, C.J. Cela s/n, 13170 Ciudad Real (Spain)

    2014-03-15

    A comparative study of two microwave driver systems (preliminary and optimized) for a 2.45 GHz hydrogen Electron Cyclotron Resonance plasma generator has been conducted. The influence on plasma behavior and parameters of stationary electric field distribution in vacuum, i.e., just before breakdown, along all the microwave excitation system is analyzed. 3D simulations of resonant stationary electric field distributions, 2D simulations of external magnetic field mapping, experimental measurements of incoming and reflected power, and electron temperature and density along the plasma chamber axis have been carried out. By using these tools, an optimized set of plasma chamber and microwave coupler has been designed paying special attention to the optimization of stationary electric field value in the center of the plasma chamber. This system shows a strong stability on plasma behavior allowing a wider range of operational parameters and even sustaining low density plasma formation without external magnetic field. In addition, the optimized system shows the capability to produce values of plasma density four times higher than the preliminary as a consequence of a deeper penetration of the magnetic resonance surface in relative high electric field zone by keeping plasma stability. The increment of the amount of resonance surface embedded in the plasma under high electric field is suggested as a key factor.

  18. Laser-plasmas in the relativistic-transparency regime: Science and applications

    Science.gov (United States)

    Fernández, Juan C.; Cort Gautier, D.; Huang, Chengkung; Palaniyappan, Sasikumar; Albright, Brian J.; Bang, Woosuk; Dyer, Gilliss; Favalli, Andrea; Hunter, James F.; Mendez, Jacob; Roth, Markus; Swinhoe, Martyn; Bradley, Paul A.; Deppert, Oliver; Espy, Michelle; Falk, Katerina; Guler, Nevzat; Hamilton, Christopher; Hegelich, Bjorn Manuel; Henzlova, Daniela; Ianakiev, Kiril D.; Iliev, Metodi; Johnson, Randall P.; Kleinschmidt, Annika; Losko, Adrian S.; McCary, Edward; Mocko, Michal; Nelson, Ronald O.; Roycroft, Rebecca; Santiago Cordoba, Miguel A.; Schanz, Victor A.; Schaumann, Gabriel; Schmidt, Derek W.; Sefkow, Adam; Shimada, Tsutomu; Taddeucci, Terry N.; Tebartz, Alexandra; Vogel, Sven C.; Vold, Erik; Wurden, Glen A.; Yin, Lin

    2017-05-01

    Laser-plasma interactions in the novel regime of relativistically induced transparency (RIT) have been harnessed to generate intense ion beams efficiently with average energies exceeding 10 MeV/nucleon (>100 MeV for protons) at "table-top" scales in experiments at the LANL Trident Laser. By further optimization of the laser and target, the RIT regime has been extended into a self-organized plasma mode. This mode yields an ion beam with much narrower energy spread while maintaining high ion energy and conversion efficiency. This mode involves self-generation of persistent high magnetic fields (˜104 T, according to particle-in-cell simulations of the experiments) at the rear-side of the plasma. These magnetic fields trap the laser-heated multi-MeV electrons, which generate a high localized electrostatic field (˜0.1 T V/m). After the laser exits the plasma, this electric field acts on a highly structured ion-beam distribution in phase space to reduce the energy spread, thus separating acceleration and energy-spread reduction. Thus, ion beams with narrow energy peaks at up to 18 MeV/nucleon are generated reproducibly with high efficiency (≈5%). The experimental demonstration has been done with 0.12 PW, high-contrast, 0.6 ps Gaussian 1.053 μm laser pulses irradiating planar foils up to 250 nm thick at 2-8 × 1020 W/cm2. These ion beams with co-propagating electrons have been used on Trident for uniform volumetric isochoric heating to generate and study warm-dense matter at high densities. These beam plasmas have been directed also at a thick Ta disk to generate a directed, intense point-like Bremsstrahlung source of photons peaked at ˜2 MeV and used it for point projection radiography of thick high density objects. In addition, prior work on the intense neutron beam driven by an intense deuterium beam generated in the RIT regime has been extended. Neutron spectral control by means of a flexible converter-disk design has been demonstrated, and the neutron beam has

  19. Electron energy distributions and electron impact source functions in Ar/N{sub 2} inductively coupled plasmas using pulsed power

    Energy Technology Data Exchange (ETDEWEB)

    Logue, Michael D., E-mail: mdlogue@umich.edu; Kushner, Mark J., E-mail: mjkush@umich.edu [Department of Electrical Engineering and Computer Science, University of Michigan, 1301 Beal Ave., Ann Arbor, Michigan 48109-2122 (United States)

    2015-01-28

    In plasma materials processing, such as plasma etching, control of the time-averaged electron energy distributions (EEDs) in the plasma allows for control of the time-averaged electron impact source functions of reactive species in the plasma and their fluxes to surfaces. One potential method for refining the control of EEDs is through the use of pulsed power. Inductively coupled plasmas (ICPs) are attractive for using pulsed power in this manner because the EEDs are dominantly controlled by the ICP power as opposed to the bias power applied to the substrate. In this paper, we discuss results from a computational investigation of EEDs and electron impact source functions in low pressure (5–50 mTorr) ICPs sustained in Ar/N{sub 2} for various duty cycles. We find there is an ability to control EEDs, and thus source functions, by pulsing the ICP power, with the greatest variability of the EEDs located within the skin depth of the electromagnetic field. The transit time of hot electrons produced in the skin depth at the onset of pulse power produces a delay in the response of the EEDs as a function of distance from the coils. The choice of ICP pressure has a large impact on the dynamics of the EEDs, whereas duty cycle has a small influence on time-averaged EEDs and source functions.

  20. Physical and plasmachemical aspects of diffuse coplanar barrier discharge as a novel atmospheric-pressure plasma source

    Science.gov (United States)

    Cernak, M.; Kovacik, D.; Zahoranova, A.; Rahel, J.

    2008-07-01

    Collaborating Czech and Slovakian university teams have recently developed an innovative plasma source, the so-called Diffuse Coplanar Surface Barrier Discharge (DCSBD), which has the potential to move a step closer to the industry requirement for in-line treatment of low-added-value materials using a highly-nonequlibrium ambient air plasma (Simor et al. 2002, The idea is to generate a thin (on the order of 0.1 mm) layer of highly-nonequlibrium plasma with a high power density (up to 100 W/cm^3) in the immediate vicinity of the treated surface and bring it into a close contact with the treated surface. Comparing to atmospheric-pressure glow discharge, volume dielectric barrier discharge, and plasma jet plasmas, such a diffuse plasma layer is believed to provide substantial advantages in energy consumption, exposure time, and technical simplicity. A brief outline of physical mechanism and basic properties of DCSBD will given using the results of emission spectroscopy, high-speed camera, and spatially resolved cross-correlation spectroscopy studies. The presentation will review also a current state of the art in in-line plasma treatment of low-cost materials and opportunities for the use of the so-called Diffuse Coplanar Surface Dielectric Barrier Discharge (DCSBD). The results obtained on the ambient air plasma treatments of textile, paper, wood, and glass illustrate that DCSBD offers outstanding performance with extremely low energy consumption for large area, uniform surface modifications of materials under continuous process conditions.