WorldWideScience

Sample records for plasma source mass

  1. Plasma source mass spectrometry in experimental nutrition.

    Science.gov (United States)

    Barnes, R M

    1998-01-01

    The development and commercial availability of plasma ion source, specifically inductively coupled plasma, mass spectrometers (ICP-MS) have significantly extended the potential application of stable isotopes for nutritional modeling. The status of research and commercial ICP-MS instruments, and their applications and limitations for stable isotopic studies are reviewed. The consequences of mass spectroscopic resolution and measurement sensitivity obtainable with quadrupole, sector, time-of-flight, and trap instruments on stable isotope analysis are examined. Requirements for reliable isotope measurements with practical biological samples including tissues and fluids are considered. The possibility for stable isotope analysis in chemically separated compounds (speciation) also is explored. On-line compound separations by chromatography or electrophoresis, for example, have been combined instrumentally with ICP-MS. Som possibilities and requirements are described for stable isotope speciation analysis.

  2. Lifetime Calculations on Collector Optics from Laser Plasma Extreme Ultraviolet Sources with Minimum Mass

    Institute of Scientific and Technical Information of China (English)

    WU Tao; WANG Xin-Bing

    2011-01-01

    An ion flux and its kinetic energy spectrum are obtained using a self similar spherically symmetric fluid model of expansion of a collisionless plasma into vacuum. According to the ion flux and energy distribution, the collector optical lifetime is estimated by knowledge of the sputtering yield of conventional Mo/Si multilayer coatings for the CO2 and Nd:YAG pulsed-laser produced plasmas based on the minimum mass tin droplet target without debris mitigation. The results show that the longer wavelength of the CO2 laser produced plasma light source is more suitable for extreme ultraviolet lithography than Nd:YAG laser in respect of fast ion debris induced sputtering damage to the collector mirror.%@@ An ion flux and its kinetic energy spectrum are obtained using a self similar spherically symmetric fluid model of expansion of a collisionless plasma into vacuum.According to the ion flux and energy distribution,the collector optical lifetime is estimated by knowledge of the sputtering yield of conventional Mo/Si multilayer coatings for the CO2 and Nd:YAG pulsed-laser produced plasmas based on the minimum mass tin droplet target without debris mitigation.The results show that the longer wavelength of the CO2 laser produced plasma light source is more suitable for extreme ultraviolet lithography than Nd:YAG laser in respect of fast ion debris induced sputtering damage to the collector mirror.

  3. Afterglow of a microwave microstrip plasma as an ion source for mass spectrometry

    Science.gov (United States)

    Pfeuffer, Kevin P.; White, Allen; Broekaert, José A. C.; Hieftje, Gary M.

    2015-01-01

    A microwave-induced plasma that was previously used for optical emission spectrometry has been repurposed as an afterglow ion source for mass spectrometry. This compact microwave discharge, termed the microstrip plasma (MSP), is operated at 20-50 W and 2.45 GHz in helium at a flow of 300 mL/min. The primary background ions present in the afterglow are ionized and protonated water clusters. An exponential dilution chamber was used to introduce volatile organic compounds into the MSP afterglow and yielded limits of detection in the 40 ppb to 7 ppm range (v/v). A hydride-generation system was also utilized for detection of volatile hydride-forming elements (arsenic, antimony, tin) in the afterglow and produced limits of detection in the 10-100 ppb range in solution. The MSP afterglow was found capable of desorption and ionization of analyte species directly from a solid substrate, suggesting its use as an ion source for ambient desorption/ionization mass spectrometry.

  4. An argon–nitrogen–hydrogen mixed-gas plasma as a robust ionization source for inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Makonnen, Yoseif; Beauchemin, Diane, E-mail: diane.beauchemin@chem.queensu.ca

    2014-09-01

    Multivariate optimization of an argon–nitrogen–hydrogen mixed-gas plasma for minimum matrix effects, while maintaining analyte sensitivity as much as possible, was carried out in inductively coupled plasma mass spectrometry. In the presence of 0.1 M Na, the 33.9 ± 3.9% (n = 13 elements) analyte signal suppression on average observed in an all-argon plasma was alleviated with the optimized mixed-gas plasma, the average being − 4.0 ± 8.8%, with enhancement in several cases. An addition of 2.3% v/v N{sub 2} in the outer plasma gas, and 0.50% v/v H{sub 2} to the central channel, as a sheath around the nebulizer gas flow, was sufficient for this drastic increase in robustness. It also reduced the background from ArO{sup +} and Ar{sub 2}{sup +} as well as oxide levels by over an order of magnitude. On the other hand, the background from NO{sup +} and ArN{sup +} increased by up to an order of magnitude while the levels of doubly-charged ions increased to 7% (versus 2.7% in an argon plasma optimized for sensitivity). Furthermore, detection limits were generally degraded by 5 to 15 fold when using the mixed-gas plasma versus the argon plasma for matrix-free solution (although they were better for several elements in 0.1 M Na). Nonetheless, the drastically increased robustness allowed the direct quantitative multielement analysis of certified ore reference materials, as well as the determination of Mo and Cd in seawater, without using any matrix-matching or internal standardization. - Highlights: • Addition of N{sub 2} to the plasma gas and H{sub 2} as a sheath gas results in a very robust ICP. • ArO{sup +} and Ar{sub 2}{sup +} background and oxide levels are reduced by over an order of magnitude. • Multielement analysis of rock digests is possible with a simple external calibration. • No internal standardization or matrix-matching is required for accurate analysis. • Cd and Mo were accurately determined in undiluted seawater.

  5. Pulsed Plasma Electron Sources

    Science.gov (United States)

    Krasik, Yakov

    2008-11-01

    Pulsed (˜10-7 s) electron beams with high current density (>10^2 A/cm^2) are generated in diodes with electric field of E > 10^6 V/cm. The source of electrons in these diodes is explosive emission plasma, which limits pulse duration; in the case E Hadas and Ya. E. Krasik, Europhysics Lett. 82, 55001 (2008).

  6. Large area plasma source

    Science.gov (United States)

    Foster, John (Inventor); Patterson, Michael (Inventor)

    2008-01-01

    An all permanent magnet Electron Cyclotron Resonance, large diameter (e.g., 40 cm) plasma source suitable for ion/plasma processing or electric propulsion, is capable of producing uniform ion current densities at its exit plane at very low power (e.g., below 200 W), and is electrodeless to avoid sputtering or contamination issues. Microwave input power is efficiently coupled with an ionizing gas without using a dielectric microwave window and without developing a throat plasma by providing a ferromagnetic cylindrical chamber wall with a conical end narrowing to an axial entrance hole for microwaves supplied on-axis from an open-ended waveguide. Permanent magnet rings are attached inside the wall with alternating polarities against the wall. An entrance magnet ring surrounding the entrance hole has a ferromagnetic pole piece that extends into the chamber from the entrance hole to a continuing second face that extends radially across an inner pole of the entrance magnet ring.

  7. A New Radio Frequency Plasma Oxygen Primary Ion Source on Nano Secondary Ion Mass Spectrometry for Improved Lateral Resolution and Detection of Electropositive Elements at Single Cell Level.

    Science.gov (United States)

    Malherbe, Julien; Penen, Florent; Isaure, Marie-Pierre; Frank, Julia; Hause, Gerd; Dobritzsch, Dirk; Gontier, Etienne; Horréard, François; Hillion, François; Schaumlöffel, Dirk

    2016-07-19

    An important application field of secondary ion mass spectrometry at the nanometer scale (NanoSIMS) is the detection of chemical elements and, in particular, metals at the subcellular level in biological samples. The detection of many trace metals requires an oxygen primary ion source to allow the generation of positive secondary ions with high yield in the NanoSIMS. The duoplasmatron oxygen source is commonly used in this ion microprobe but cannot achieve the same quality of images as the cesium primary ion source used to produce negative secondary ions (C(-), CN(-), S(-), P(-)) due to a larger primary ion beam size. In this paper, a new type of an oxygen ion source using a rf plasma is fitted and characterized on a NanoSIMS50L. The performances of this primary ion source in terms of current density and achievable lateral resolution have been characterized and compared to the conventional duoplasmatron and cesium sources. The new rf plasma oxygen source offered a net improvement in terms of primary beam current density compared to the commonly used duoplasmatron source, which resulted in higher ultimate lateral resolutions down to 37 nm and which provided a 5-45 times higher apparent sensitivity for electropositive elements. Other advantages include a better long-term stability and reduced maintenance. This new rf plasma oxygen primary ion source has been applied to the localization of essential macroelements and trace metals at basal levels in two biological models, cells of Chlamydomonas reinhardtii and Arabidopsis thaliana.

  8. Radiochemical Separation and Measurement by Mass Spectrometry with Magnetic Sector with Inductively Coupled Plasma source (ICP-SFMS of Plutonium Isotopes in Soil Samples

    Directory of Open Access Journals (Sweden)

    C. O. Torres-Cortés

    2016-08-01

    Full Text Available The aim of this work is twofold: to optimize the radiochemical separation of Plutonium (Pu from soil samples, and to measure the Pu concentration. Soil samples were prepared using acid digestion assisted by microwaves; then, Pu purification was carried out with Pu AG1X8 resin. Pu isotopes were measured using Mass Spectrometry with Magnetic Sector with Inductively Coupled Plasma source (ICP-SFMS. In order to reduce the interference due to the presence of 238UH+ in the samples a desolvation system (Apex was used. The limit of detection (LOD of Pu was determined. The efficiency of Pu recovery from soil samples varies from 70 to 93%.

  9. Speciation analysis by gas chromatography with plasma source spectrometric detection

    Science.gov (United States)

    Łobiński, Ryszard; Adams, Freddy C.

    State-of-the-art species-selective analysis by gas chromatography (GC) with plasma source spectrometric detection is discussed for organometal and organometalloid compounds. Various plasmas, inductively coupled plasma, microwave induced plasma, capacitatively coupled plasma, direct current plasma and alternating current plasma, are characterized and critically compared as sources of radiation for atomic emission spectrometry and sources of ions for mass spectrometry. Interfaces between gas chromatography (packed, wide-bore, capillary and multicapillary) and plasma source spectrometry are characterized. Particular emphasis is given to applications of GC with plasma source detection to real-world analytical problems, which are comprehensively reviewed. The use of plasmas for the acquisition of auxiliary molecular information such as empirical formulae and structural information is discussed. Recent developments relating to sample preparation and presentation to the hyphenated system are addressed. The most significant trends in speciation analysis are highlighted.

  10. Determination of Glucosamine in Human Plasma by High-Performance Liquid Chromatography-Atmospheric Pressure Chemical Ionization Source-Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Xingchen Zhou

    2011-01-01

    Full Text Available A sensitive, specific, and rapid high-performance liquid chromatography-atmospheric pressure chemical ionization source-tandem mass spectrometry (HPLC-APCI-MS/MS method for the determination of glucosamine in human plasma was developed and validated. Plasma samples were processed by protein precipitation with dehydrated ethanol, and the chromatographic separation was performed on an Agilent XDB-C18 column with a mobile phase of methanol—0.2% formic acid solution (70 : 30, v/v. Mass spectrometric quantification was carried out in the multiple reaction monitoring (MRM mode, monitoring ion transitions of m/z 180.1 to m/z 162.1 with collision energy (CE of 2 eV for glucosamine and m/z 181.1 to m/z 163.1 with CE of 2 eV for the internal standard (IS in positive ion mode. The linear calibration curves covered a concentration range of 53.27–3409 ng/mL with a lower limit of quantification (LLOQ of 53.27 ng/mL. The extraction recovery of glucosamine was greater than 101.7%. The intra- and interday precisions for glucosamine were less than 10%, and the accuracies were between 93.7% and 102.6%, determined from quality control (QC samples of three representative concentrations. The method has been successfully applied to determining the plasma concentration of glucosamine in a clinical pharmacokinetic study involving 20 healthy Chinese male volunteers.

  11. 21 CFR 640.60 - Source Plasma.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Source Plasma. 640.60 Section 640.60 Food and... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.60 Source Plasma. The proper name of the product shall be Source Plasma. The product is defined as the fluid portion of human blood...

  12. Miniaturized cathodic arc plasma source

    Science.gov (United States)

    Anders, Andre; MacGill, Robert A.

    2003-04-15

    A cathodic arc plasma source has an anode formed of a plurality of spaced baffles which extend beyond the active cathode surface of the cathode. With the open baffle structure of the anode, most macroparticles pass through the gaps between the baffles and reflect off the baffles out of the plasma stream that enters a filter. Thus the anode not only has an electrical function but serves as a prefilter. The cathode has a small diameter, e.g. a rod of about 1/4 inch (6.25 mm) diameter. Thus the plasma source output is well localized, even with cathode spot movement which is limited in area, so that it effectively couples into a miniaturized filter. With a small area cathode, the material eroded from the cathode needs to be replaced to maintain plasma production. Therefore, the source includes a cathode advancement or feed mechanism coupled to cathode rod. The cathode also requires a cooling mechanism. The movable cathode rod is housed in a cooled metal shield or tube which serves as both a current conductor, thus reducing ohmic heat produced in the cathode, and as the heat sink for heat generated at or near the cathode. Cooling of the cathode housing tube is done by contact with coolant at a place remote from the active cathode surface. The source is operated in pulsed mode at relatively high currents, about 1 kA. The high arc current can also be used to operate the magnetic filter. A cathodic arc plasma deposition system using this source can be used for the deposition of ultrathin amorphous hard carbon (a-C) films for the magnetic storage industry.

  13. Tunable single-photon ionization TOF mass spectrometry using laser-produced plasma as the table-top VUV light source.

    Science.gov (United States)

    Di Palma, Tonia M; Prati, Maria V; Borghese, Antonio

    2009-12-01

    Here we report on a laser plasma-based tunable VUV photoionization time-of-flight (TOF) mass spectrometer conceived mainly to study complex gaseous mixtures. Ionizing photons at tunable vacuum UV (VUV) wavelengths are generated by a gas-target laser-produced plasma, spectrally dispersed in the range 100-160 nm and efficiently focused onto a sample molecular beam. As a test case, we studied the exhaust gas of a four-stroke moped, a typical example of a complex gaseous mixture. Due to the VUV "soft" ionization, the mass spectra are less congested and more easily interpretable. Substituted benzene derivatives are found to give the most intense signals. Several aliphatic hydrocarbons are also detected. The use of tunable VUV radiation allowed the investigation of the contribution of isomers in the mass spectrum from the onset and shape of the photoionization efficiency spectra. Semiquantitative analysis was performed using known literature data detailing the photoionization cross sections. Our findings suggest that using combined data on the mass/photoionization efficiency spectra may be very helpful for a comprehensive analysis of complex gaseous mixtures.

  14. Some plasma aspects and plasma diagnostics of ion sources.

    Science.gov (United States)

    Wiesemann, Klaus

    2008-02-01

    We consider plasma properties in the most advanced type of plasma ion sources, electron cyclotron resonance ion sources for highly charged ions. Depending on the operation conditions the plasma in these sources may be highly ionized, which completely changes its transport properties. The most striking difference to weakly ionized plasma is that diffusion will become intrinsically ambipolar. We further discuss means of plasma diagnostics. As noninvasive diagnostic methods we will discuss analysis of the ion beam, optical spectroscopy, and measurement of the x-ray bremsstrahlung continuum. From beam analysis and optical spectroscopy one may deduce ion densities, and electron densities and distribution functions as a mean over the line of sight along the axis (optical spectroscopy) or at the plasma edge (ion beam). From x-ray spectra one obtains information about the population of highly energetic electrons and the energy transfer from the driving electromagnetic waves to the plasma -- basic data for plasma modeling.

  15. Absolute number densities of helium metastable atoms determined by atomic absorption spectroscopy in helium plasma-based discharges used as ambient desorption/ionization sources for mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Reininger, Charlotte; Woodfield, Kellie [Brigham Young University, Department of Chemistry and Biochemistry, Provo, UT 84602 (United States); Keelor, Joel D.; Kaylor, Adam; Fernández, Facundo M. [Georgia Institute of Technology, School of Chemistry and Biochemistry, Atlanta, GA 30332 (United States); Farnsworth, Paul B., E-mail: paul_farnsworth@byu.edu [Brigham Young University, Department of Chemistry and Biochemistry, Provo, UT 84602 (United States)

    2014-10-01

    The absolute number densities of helium atoms in the 2s {sup 3}S{sub 1} metastable state were determined in four plasma-based ambient desorption/ionization sources by atomic absorption spectroscopy. The plasmas included a high-frequency dielectric barrier discharge (HF-DBD), a low temperature plasma (LTP), and two atmospheric-pressure glow discharges, one with AC excitation and the other with DC excitation. Peak densities in the luminous plumes downstream from the discharge capillaries of the HF-DBD and the LTP were 1.39 × 10{sup 12} cm{sup −3} and 0.011 × 10{sup 12} cm{sup −3}, respectively. Neither glow discharge produced a visible afterglow, and no metastable atoms were detected downstream from the capillary exits. However, densities of 0.58 × 10{sup 12} cm{sup −3} and 0.97 × 10{sup 12} cm{sup −3} were measured in the interelectrode regions of the AC and DC glow discharges, respectively. Time-resolved measurements of metastable atom densities revealed significant random variations in the timing of pulsed absorption signals with respect to the voltage waveforms applied to the discharges. - Highlights: • We determine He metastable number densities for four plasma types • The highest number densities were observed in a dielectric barrier discharge • No helium metastable atoms were observed downstream from the exits of glow discharges.

  16. Plasma Mass Filters For Nuclear Waste Reprocessing

    Energy Technology Data Exchange (ETDEWEB)

    Fetterman, Abraham J. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Fisch, Nathaniel J. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States)

    2011-05-01

    Practical disposal of nuclear waste requires high-throughput separation techniques. The most dangerous part of nuclear waste is the fission product, which contains the most active and mobile radioisotopes and produces most of the heat. We suggest that the fission products could be separated as a group from nuclear waste using plasma mass filters. Plasmabased processes are well suited to separating nuclear waste, because mass rather than chemical properties are used for separation. A single plasma stage can replace several stages of chemical separation, producing separate streams of bulk elements, fission products, and actinoids. The plasma mass filters may have lower cost and produce less auxiliary waste than chemical processing plants. Three rotating plasma configurations are considered that act as mass filters: the plasma centrifuge, the Ohkawa filter, and the asymmetric centrifugal trap.

  17. Plasma Mass Filters For Nuclear Waste Reprocessing

    Energy Technology Data Exchange (ETDEWEB)

    Abraham J. Fetterman and Nathaniel J. Fisch

    2011-05-26

    Practical disposal of nuclear waste requires high-throughput separation techniques. The most dangerous part of nuclear waste is the fission product, which contains the most active and mobile radioisotopes and produces most of the heat. We suggest that the fission products could be separated as a group from nuclear waste using plasma mass filters. Plasmabased processes are well suited to separating nuclear waste, because mass rather than chemical properties are used for separation. A single plasma stage can replace several stages of chemical separation, producing separate streams of bulk elements, fission products, and actinoids. The plasma mass filters may have lower cost and produce less auxiliary waste than chemical processing plants. Three rotating plasma configurations are considered that act as mass filters: the plasma centrifuge, the Ohkawa filter, and the asymmetric centrifugal trap.

  18. Plasma-Based Ion Beam Sources

    Energy Technology Data Exchange (ETDEWEB)

    Loeb, H. W.

    2005-07-01

    Ion beam sources cover a broad spectrum of scientific and technical applications delivering ion currents between less than 1 mA and about 100 A at acceleration voltages between 100 V and 100 kV. The ions are mostly generated by electron collisions in a gas discharge and then extracted from the discharge plasma, focused and post-accelerated by single- or multi-aperture electrode systems. Some important applications require the neutralization of the exhausted beam either by charge exchange or by admixture of electrons. In the first part of the paper, the theory of ionization by electron impact, the energy and carrier balances in the plasma, and the extraction and focusing mechanisms will be outlined. The principles of the preferred gas discharges and of the ion beam sources based on them are discussed; i.e. of the Penning, bombardment, arc, duoplasmatron, radio frequency, and microwave types. In the second part of the paper, the special requirements of the different applications are described together with the related source hardware. One distinguishes: 1. Single-aperture ion sources producing protons, heavy ions, isotope ions, etc. for particle accelerators, ion microprobes, mass spectrometers, isotope separators, etc.; quality determinative quantities are brightness, emittance, energy width, etc. 2. Broad-beam multi-aperture injector sources for fusion machines with positive or negative deuterium ions; very high beam densities, small portions of molecular ions, flat beam profiles with small divergence angles, etc. are required. 3. Broad-beam multi-aperture ion thrusters for space propulsion operated with singly charged xenon ions; high efficiencies, reliable operation, and long lifetimes are most important. Spin-offs are applied in industry for material processing. Referring to these applications, the following sources will be described in some detail: 1. Cold cathode and filament driven sources, capillary arc and plasmatron types, microwave and ECR-sources. 2

  19. Plasma Cathode Electron Sources Physics, Technology, Applications

    CERN Document Server

    Oks, Efim

    2006-01-01

    This book fills the gap for a textbook describing this kind of electron beam source in a systematic and thorough manner: from physical processes of electron emission to examples of real plasma electron sources and their applications.

  20. The study of helicon plasma source.

    Science.gov (United States)

    Miao, Ting-Ting; Zhao, Hong-Wei; Liu, Zhan-Wen; Shang, Yong; Sun, Liang-Ting; Zhang, Xue-Zhen; Zhao, Huan-Yu

    2010-02-01

    Helicon plasma source is known as efficient generator of uniform and high density plasma. A helicon plasma source was developed for investigation of plasma neutralization and plasma lens in the Institute of Modern Physics in China. In this paper, the characteristics of helicon plasma have been studied by using Langmuir four-probe and a high argon plasma density up to 3.9x10(13) cm(-3) have been achieved with the Nagoya type III antenna at the conditions of the magnetic intensity of 200 G, working gas pressure of 2.8x10(-3) Pa, and rf power of 1200 W with a frequency of 27.12 MHz. In the experiment, the important phenomena have been found: for a given magnetic induction intensity, the plasma density became greater with the increase in rf power and tended to saturation, and the helicon mode appeared at the rf power between 200 and 400 W.

  1. Absolute number densities of helium metastable atoms determined by atomic absorption spectroscopy in helium plasma-based discharges used as ambient desorption/ionization sources for mass spectrometry

    Science.gov (United States)

    Reininger, Charlotte; Woodfield, Kellie; Keelor, Joel D.; Kaylor, Adam; Fernández, Facundo M.; Farnsworth, Paul B.

    2014-10-01

    The absolute number densities of helium atoms in the 2s 3S1 metastable state were determined in four plasma-based ambient desorption/ionization sources by atomic absorption spectroscopy. The plasmas included a high-frequency dielectric barrier discharge (HF-DBD), a low temperature plasma (LTP), and two atmospheric-pressure glow discharges, one with AC excitation and the other with DC excitation. Peak densities in the luminous plumes downstream from the discharge capillaries of the HF-DBD and the LTP were 1.39 × 1012 cm- 3 and 0.011 × 1012 cm- 3, respectively. Neither glow discharge produced a visible afterglow, and no metastable atoms were detected downstream from the capillary exits. However, densities of 0.58 × 1012 cm- 3 and 0.97 × 1012 cm- 3 were measured in the interelectrode regions of the AC and DC glow discharges, respectively. Time-resolved measurements of metastable atom densities revealed significant random variations in the timing of pulsed absorption signals with respect to the voltage waveforms applied to the discharges.

  2. Surface plasma source with saddle antenna radio frequency plasma generator.

    Science.gov (United States)

    Dudnikov, V; Johnson, R P; Murray, S; Pennisi, T; Piller, C; Santana, M; Stockli, M; Welton, R

    2012-02-01

    A prototype RF H(-) surface plasma source (SPS) with saddle (SA) RF antenna is developed which will provide better power efficiency for high pulsed and average current, higher brightness with longer lifetime and higher reliability. Several versions of new plasma generators with small AlN discharge chambers and different antennas and magnetic field configurations were tested in the plasma source test stand. A prototype SA SPS was installed in the Spallation Neutron Source (SNS) ion source test stand with a larger, normal-sized SNS AlN chamber that achieved unanalyzed peak currents of up to 67 mA with an apparent efficiency up to 1.6 mA∕kW. Control experiments with H(-) beam produced by SNS SPS with internal and external antennas were conducted. A new version of the RF triggering plasma gun has been designed. A saddle antenna SPS with water cooling is fabricated for high duty factor testing.

  3. Saturn Plasma Sources and Associated Transport Processes

    Science.gov (United States)

    Blanc, M.; Andrews, D. J.; Coates, A. J.; Hamilton, D. C.; Jackman, C. M.; Jia, X.; Kotova, A.; Morooka, M.; Smith, H. T.; Westlake, J. H.

    2015-10-01

    This article reviews the different sources of plasma for Saturn's magnetosphere, as they are known essentially from the scientific results of the Cassini-Huygens mission to Saturn and Titan. At low and medium energies, the main plasma source is the H2O cloud produced by the "geyser" activity of the small satellite Enceladus. Impact ionization of this cloud occurs to produce on the order of 100 kg/s of fresh plasma, a source which dominates all the other ones: Titan (which produces much less plasma than anticipated before the Cassini mission), the rings, the solar wind (a poorly known source due to the lack of quantitative knowledge of the degree of coupling between the solar wind and Saturn's magnetosphere), and the ionosphere. At higher energies, energetic particles are produced by energy diffusion and acceleration of lower energy plasma produced by the interchange instabilities induced by the rapid rotation of Saturn, and possibly, for the highest energy range, by contributions from the CRAND process acting inside Saturn's magnetosphere. Discussion of the transport and acceleration processes acting on these plasma sources shows the importance of rotation-induced radial transport and energization of the plasma, and also shows how much the unexpected planetary modulation of essentially all plasma parameters of Saturn's magnetosphere remains an unexplained mystery.

  4. Hollow-Cathode Source Generates Plasma

    Science.gov (United States)

    Deininger, W. D.; Aston, G.; Pless, L. C.

    1989-01-01

    Device generates argon, krypton, or xenon plasma via thermionic emission and electrical discharge within hollow cathode and ejects plasma into surrounding vacuum. Goes from cold start up to full operation in less than 5 s after initial application of power. Exposed to moist air between operations without significant degradation of starting and running characteristics. Plasma generated by electrical discharge in cathode barrel sustained and aided by thermionic emission from emitter tube. Emitter tube does not depend on rare-earth oxides, making it vulnerable to contamination by exposure to atmosphere. Device modified for use as source of plasma in laboratory experiments or industrial processes.

  5. Sources of Pressure in Titan's Plasma Environment

    CERN Document Server

    Achilleos, N; Bertucci, C; Guio, P; Romanelli, N; Sergis, N

    2013-01-01

    In order to analyze varying plasma conditions upstream of Titan, we have combined a physical model of Saturn's plasmadisk with a geometrical model of the oscillating current sheet. During modeled oscillation phases where Titan is furthest from the current sheet, the main sources of plasma pressure in the near-Titan space are the magnetic pressure and, for disturbed conditions, the hot plasma pressure. When Titan is at the center of the sheet, the main source is the dynamic pressure associated with Saturn's cold, subcorotating plasma. Total pressure at Titan (dynamic plus thermal plus magnetic) typically increases by a factor of five as the current sheet center is approached. The predicted incident plasma flow direction deviates from the orbital plane of Titan by < 10 deg. These results suggest a correlation between the location of magnetic pressure maxima and the oscillation phase of the plasmasheet.

  6. Ion transport from plasma ion source at ISOLTRAP

    CERN Document Server

    Steinsberger, Timo Pascal

    2017-01-01

    In this report, my work as CERN Summer Student at the ISOLTRAP experiment at ISOLDE is described. A new plasma ion source used as oine source for calibration and implemented before my arrival was commissioned and transportation settings for the produced ions to the ion traps were found. The cyclotron frequencies of 40Ar and the xenon isotopes 129-132Xe were measured using time-of-flight and phase-imaging ion-cyclotron-resonance mass spectroscopy.

  7. Study of Coupling between a Plasma Source and Plasma Fluctuations

    Science.gov (United States)

    Berumen, Jorge; Chu, Feng; Hood, Ryan; Mattingly, Sean; Rogers, Anthony; Skiff, Fred

    2014-10-01

    An experimental study on the coupling between a plasma source and plasma fluctuations in a cylindrical, magnetized, singly-ionized Argon inductively-coupled gas discharge plasma that is weakly collisional is presented. Typical plasma conditions are n ~1010 cm-3 Te ~ 3 eV and B ~ 1 kG. Amplitude Modulation (AM) of the inductively-coupled RF plasma source is produced near the fundamental-mode ion-acoustic wave frequency (~1 kHz) to study the effects of the source-wave interaction and plasma production. Density fluctuation measurements are implemented using Laser-Induced Fluorescence techniques and Langmuir probes. We apply coherent detection with respect to the wave frequency to obtain the perturbed ion distribution function associated with the waves. Measurements of fluctuating I-V traces from a Langmuir probe array and antenna current load are also used to show the effects of the interaction. We would like to acknowledge DOE DE-FG02-99ER54543 for their financial support throughout this research.

  8. Meter scale plasma source for plasma wakefield experiments

    Science.gov (United States)

    Vafaei-Najafabadi, N.; Shaw, J. L.; Marsh, K. A.; Joshi, C.; Hogan, M. J.

    2012-12-01

    High accelerating gradients generated by a high density electron beam moving through plasma has been used to double the energy of the SLAC electron beam [1]. During that experiment, the electron current density was high enough to generate its own plasma without significant head erosion. In the newly commissioned FACET facility at SLAC, the peak current will be lower and without pre-ionization, head erosion will be a significant challenge for the planned experiments. In this work we report on our design of a meter scale plasma source for these experiments to effectively avoid the problem of head erosion. The plasma source is based on a homogeneous metal vapor gas column that is generated in a heat pipe oven [2]. A lithium oven over 30 cm long at densities over 1017 cm-3 has been constructed and tested at UCLA. The plasma is then generated by coupling a 10 TW short pulse Ti:Sapphire laser into the gas column using an axicon lens setup. The Bessel profile of the axicon setup creates a region of high intensity that can stretch over the full length of the gas column with approximately constant diameter. In this region of high intensity, the alkali metal vapor is ionized through multi-photon ionization process. In this manner, a fully ionized meter scale plasma of uniform density can be formed. Methods for controlling the plasma diameter and length will also be discussed.

  9. Meter scale plasma source for plasma wakefield experiments

    Energy Technology Data Exchange (ETDEWEB)

    Vafaei-Najafabadi, N.; Shaw, J. L.; Marsh, K. A.; Joshi, C.; Hogan, M. J. [Department of Electrical Engineering, University of California Los Angeles, Los Angeles, CA 90095 (United States); SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States)

    2012-12-21

    High accelerating gradients generated by a high density electron beam moving through plasma has been used to double the energy of the SLAC electron beam [1]. During that experiment, the electron current density was high enough to generate its own plasma without significant head erosion. In the newly commissioned FACET facility at SLAC, the peak current will be lower and without pre-ionization, head erosion will be a significant challenge for the planned experiments. In this work we report on our design of a meter scale plasma source for these experiments to effectively avoid the problem of head erosion. The plasma source is based on a homogeneous metal vapor gas column that is generated in a heat pipe oven [2]. A lithium oven over 30 cm long at densities over 10{sup 17} cm{sup -3} has been constructed and tested at UCLA. The plasma is then generated by coupling a 10 TW short pulse Ti:Sapphire laser into the gas column using an axicon lens setup. The Bessel profile of the axicon setup creates a region of high intensity that can stretch over the full length of the gas column with approximately constant diameter. In this region of high intensity, the alkali metal vapor is ionized through multi-photon ionization process. In this manner, a fully ionized meter scale plasma of uniform density can be formed. Methods for controlling the plasma diameter and length will also be discussed.

  10. Plasma-based EUV light source

    Science.gov (United States)

    Shumlak, Uri; Golingo, Raymond; Nelson, Brian A.

    2010-11-02

    Various mechanisms are provided relating to plasma-based light source that may be used for lithography as well as other applications. For example, a device is disclosed for producing extreme ultraviolet (EUV) light based on a sheared plasma flow. The device can produce a plasma pinch that can last several orders of magnitude longer than what is typically sustained in a Z-pinch, thus enabling the device to provide more power output than what has been hitherto predicted in theory or attained in practice. Such power output may be used in a lithography system for manufacturing integrated circuits, enabling the use of EUV wavelengths on the order of about 13.5 nm. Lastly, the process of manufacturing such a plasma pinch is discussed, where the process includes providing a sheared flow of plasma in order to stabilize it for long periods of time.

  11. Plasma sources of solar system magnetospheres

    CERN Document Server

    Blanc, Michel; Chappell, Charles; Krupp, Norbert

    2016-01-01

    This volume reviews what we know of the corresponding plasma source for each intrinsically magnetized planet. Plasma sources fall essentially in three categories: the solar wind, the ionosphere (both prevalent on Earth), and the satellite-related sources. Throughout the text, the case of each planet is described, including the characteristics, chemical composition and intensity of each source. The authors also describe how the plasma generated at the source regions is transported to populate the magnetosphere, and how it is later lost. To summarize, the dominant sources are found to be the solar wind and sputtered surface ions at Mercury, the solar wind and ionosphere at Earth (the relative importance of the two being discussed in a specific introductory chapter), Io at Jupiter and – a big surprise of the Cassini findings – Enceladus at Saturn. The situation for Uranus and Neptune, which were investigated by only one fly-by each, is still open and requires further studies and exploration. In the final cha...

  12. A Microfabricated Inductively Coupled Plasma Excitation Source

    Institute of Scientific and Technical Information of China (English)

    WANG Yong-Qing; PU Yong-Ni; SUN Rong-Xia; TANG Yu-Jun; CHEN Wen-Jun; LOU Jian-Zhong; MA Wen

    2008-01-01

    A novel miniaturization of inductively coupled plasma(ICP)source based on printed circuit produced using micro-fabrication techniques is presented.The basic parameters of the novel ICP,including its radio frequency,power loss,size,and argon consumption are less than 1% of that for the case of atmospheric pressure ICP source.For example,at 100 Pa of argon gas pressure,the present ICP source can be ignited by using the rf power less than 3.5 W.Potential applications of the ICP is discussed.

  13. Plasma wake field XUV radiation source

    Energy Technology Data Exchange (ETDEWEB)

    Prono, Daniel S. (Los Alamos, NM); Jones, Michael E. (Los Alamos, NM)

    1997-01-01

    A XUV radiation source uses an interaction of electron beam pulses with a gas to create a plasma radiator. A flowing gas system (10) defines a circulation loop (12) with a device (14), such as a high pressure pump or the like, for circulating the gas. A nozzle or jet (16) produces a sonic atmospheric pressure flow and increases the density of the gas for interacting with an electron beam. An electron beam is formed by a conventional radio frequency (rf) accelerator (26) and electron pulses are conventionally formed by a beam buncher (28). The rf energy is thus converted to electron beam energy, the beam energy is used to create and then thermalize an atmospheric density flowing gas to a fully ionized plasma by interaction of beam pulses with the plasma wake field, and the energetic plasma then loses energy by line radiation at XUV wavelengths Collection and focusing optics (18) are used to collect XUV radiation emitted as line radiation when the high energy density plasma loses energy that was transferred from the electron beam pulses to the plasma.

  14. Plasma Sources for Medical Applications - A Comparison of Spot Like Plasmas and Large Area Plasmas

    Science.gov (United States)

    Weltmann, Klaus-Dieter

    2015-09-01

    Plasma applications in life science are currently emerging worldwide. Whereas today's commercially available plasma surgical technologies such as argon plasma coagulation (APC) or ablation are mainly based on lethal plasma effects on living systems, the newly emerging therapeutic applications will be based on selective, at least partially non-lethal, possibly stimulating plasma effects on living cells and tissue. Promising results could be obtained by different research groups worldwide revealing a huge potential for the application of low temperature atmospheric pressure plasma in fields such as tissue engineering, healing of chronic wounds, treatment of skin diseases, tumor treatment based on specific induction of apoptotic processes, inhibition of biofilm formation and direct action on biofilms or treatment of dental diseases. The development of suitable and reliable plasma sources for the different therapies requires an in-depth knowledge of their physics, chemistry and parameters. Therefore much basic research still needs to be conducted to minimize risk and to provide a scientific fundament for new plasma-based medical therapies. It is essential to perform a comprehensive assessment of physical and biological experiments to clarify minimum standards for plasma sources for applications in life science and for comparison of different sources. One result is the DIN-SPEC 91315, which is now open for further improvements. This contribution intends to give an overview on the status of commercial cold plasma sources as well as cold plasma sources still under development for medical use. It will discuss needs, prospects and approaches for the characterization of plasmas from different points of view. Regarding the manageability in everyday medical life, atmospheric pressure plasma jets (APPJ) and dielectric barrier discharges (DBD) are of special interest. A comprehensive risk-benefit assessment including the state of the art of commercial sources for medical use

  15. Burning plasmas in ITER for energy source

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Nobuyuki [Atomic Energy Commission, Tokyo (Japan)

    2002-10-01

    Fusion research and development has two aspects. One is an academic research on science and technology, i.e., discovery and understanding of unexpected phenomena and, development of innovative technology, respectively. The other is energy source development to realize fusion as a viable energy future. Fusion research has been made remarkable progress in the past several decades, and ITER will soon realize burning plasma that is essential for both academic research and energy development. With ITER, scientific research on unknown phenomena such as self-organization of the plasma in burning state will become possible and it contributes to create a variety of academic outcome. Fusion researchers will have a responsibility to generate actual energy, and electricity generation immediately after the success of burning plasma control experiment in ITER is the next important step that has to be discussed seriously. (author)

  16. Kinetic models for the VASIMR thruster helicon plasma source

    Science.gov (United States)

    Batishchev, Oleg; Molvig, Kim

    2001-10-01

    Helicon gas discharge [1] is widely used by industry because of its remarkable efficiency [2]. High energy and fuel efficiencies make it very attractive for space electrical propulsion applications. For example, helicon plasma source is used in the high specific impulse VASIMR [3] plasma thruster, including experimental prototypes VX-3 and upgraded VX-10 [4] configurations, which operate with hydrogen (deuterium) and helium plasmas. We have developed a set of models for the VASIMR helicon discharge. Firstly, we use zero-dimensional energy and mass balance equations to characterize partially ionized gas condition/composition. Next, we couple it to one-dimensional hybrid model [6] for gas flow in the quartz tube of the helicon. We compare hybrid model results to a purely kinetic simulation of propellant flow in gas feed + helicon source subsystem. Some of the experimental data [3-4] are explained. Lastly, we discuss full-scale kinetic modeling of coupled gas and plasmas [5-6] in the helicon discharge. [1] M.A.Lieberman, A.J.Lihtenberg, 'Principles of ..', Wiley, 1994; [2] F.F.Chen, Plas. Phys. Contr. Fus. 33, 339, 1991; [3] F.Chang-Diaz et al, Bull. APS 45 (7) 129, 2000; [4] J.Squire et al., Bull. APS 45 (7) 130, 2000; [5] O.Batishchev et al, J. Plasma Phys. 61, part II, 347, 1999; [6] O.Batishchev, K.Molvig, AIAA technical paper 2000-3754, -14p, 2001.

  17. 21 CFR 640.74 - Modification of Source Plasma.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Modification of Source Plasma. 640.74 Section 640...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.74 Modification of Source Plasma. (a) Upon approval by the Director, Center for Biologics Evaluation and Research, Food and...

  18. Mass spectrometry in a multicusp ion source

    Energy Technology Data Exchange (ETDEWEB)

    Mullan, A.A. (Applied Physical Science, University of Ulster, Coleraine (Northern Ireland)); Graham, W.G. (Physics Department, Queen' s University, Belfast, (Northern Ireland))

    1990-08-05

    Mass spectrometry has been used for the detection of positive and negative ions in a multicusp ion source operating with both hydrogen and deuterium gas. The mass spectrometer operation has been optimized and it is shown that applying ion extraction voltages can disturb the discharge. Using this technique combined with a Langmuir probe technique we are able to study the positive ionic fractions present when operating with both gases (and the negative ion densities.)

  19. Magnetic plasma confinement for laser ion source.

    Science.gov (United States)

    Okamura, M; Adeyemi, A; Kanesue, T; Tamura, J; Kondo, K; Dabrowski, R

    2010-02-01

    A laser ion source (LIS) can easily provide a high current beam. However, it has been difficult to obtain a longer beam pulse while keeping a high current. On occasion, longer beam pulses are required by certain applications. For example, more than 10 micros of beam pulse is required for injecting highly charged beams to a large sized synchrotron. To extend beam pulse width, a solenoid field was applied at the drift space of the LIS at Brookhaven National Laboratory. The solenoid field suppressed the diverging angle of the expanding plasma and the beam pulse was widened. Also, it was observed that the plasma state was conserved after passing through a few hundred gauss of the 480 mm length solenoid field.

  20. A comparison of laser ablation-inductively coupled plasma-mass spectrometry and high-resolution continuum source graphite furnace molecular absorption spectrometry for the direct determination of bromine in polymers

    Science.gov (United States)

    de Gois, Jefferson S.; Van Malderen, Stijn J. M.; Cadorim, Heloisa R.; Welz, Bernhard; Vanhaecke, Frank

    2017-06-01

    This work describes the development and comparison of two methods for the direct determination of Br in polymer samples via solid sampling, one using laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) and the other using high-resolution continuum source graphite furnace molecular absorption spectrometry with direct solid sample analysis (HR-CS SS-GF MAS). The methods were optimized and their accuracy was evaluated by comparing the results obtained for 6 polymeric certified reference materials (CRMs) with the corresponding certified values. For Br determination with LA-ICP-MS, the 79Br+ signal could be monitored interference-free. For Br determination via HR-CS SS-GF MAS, the CaBr molecule was monitored at 625.315 nm with integration of the central pixel ± 1. Bromine quantification by LA-ICP-MS was performed via external calibration against a single CRM while using the 12C+ signal as an internal standard. With HR-CS SS-GF MAS, Br quantification could be accomplished using external calibration against aqueous standard solutions. Except for one LA-ICP-MS result, the concentrations obtained with both techniques were in agreement with the certified values within the experimental uncertainty as evidenced using a t-test (95% confidence level). The limit of quantification was determined to be 100 μg g- 1 Br for LA-ICP-MS and 10 μg g- 1 Br for HR-CS SS-GF MAS.

  1. Laser-produced plasma source system development

    Science.gov (United States)

    Fomenkov, Igor V.; Brandt, David C.; Bykanov, Alexander N.; Ershov, Alexander I.; Partlo, William N.; Myers, David W.; Böwering, Norbert R.; Vaschenko, Georgiy O.; Khodykin, Oleh V.; Hoffman, Jerzy R.; Vargas L., Ernesto; Simmons, Rodney D.; Chavez, Juan A.; Chrobak, Christopher P.

    2007-03-01

    This paper describes the development of laser produced plasma (LPP) technology as an EUV source for advanced scanner lithography applications in high volume manufacturing. EUV lithography is expected to succeed 193 nm immersion technology for critical layer patterning below 32 nm beginning with beta generation scanners in 2009. This paper describes the development status of subsystems most critical to the performance to meet joint scanner manufacturer requirements and semiconductor industry standards for reliability and economic targets for cost of ownership. The intensity and power of the drive laser are critical parameters in the development of extreme ultraviolet LPP lithography sources. The conversion efficiency (CE) of laser light into EUV light is strongly dependent on the intensity of the laser energy on the target material at the point of interaction. The total EUV light generated then scales directly with the total incident laser power. The progress on the development of a short pulse, high power CO2 laser for EUV applications is reported. The lifetime of the collector mirror is a critical parameter in the development of extreme ultra-violet LPP lithography sources. The deposition of target materials and contaminants, as well as sputtering of the collector multilayer coating and implantation of incident particles can reduce the reflectivity of the mirror substantially over the exposure time even though debris mitigation schemes are being employed. The results of measurements of high energy ions generated by a short-pulse CO2 laser on a laser-produced plasma EUV light source with Sn target are presented. Droplet generation is a key element of the LPP source being developed at Cymer for EUV lithography applications. The main purpose of this device is to deliver small quantities of liquid target material as droplets to the laser focus. The EUV light in such configuration is obtained as a result of creating a highly ionized plasma from the material of the

  2. Charge-exchange source terms in magnetohydrodynamic plasmas

    Science.gov (United States)

    DeStefano, Anthony M.; Heerikhuisen, Jacob

    2017-05-01

    In the modeling of space plasma environments, source terms are often used to couple separate species of particles and/or fluids. There have been many techniques developed over the years to make such coupling more tractable while maintaining maximum physical fidelity. In our current application we use the formalism of the Boltzmann collision integral to compute source terms due to charge-exchange events in the heliosphere. The charge-exchange cross sections often encountered in heliospheric interactions can be fit to laboratory data, but in most cases cannot be directly integrated over analytically. Therefore, researchers often employ various levels of approximation, either semi-analytic or numerical. We explore several assumptions to the charge-exchange source term integrals, namely using Maxwellian velocity spaces for like-mass species and either hard-sphere, power-law, or exact forms of the cross section.

  3. Physical properties of erupting plasma associated with coronal mass ejections

    Science.gov (United States)

    Lee, J.; Raymond, J. C.; Reeves, K. K.; Moon, Y.; Kim, K.

    2013-12-01

    We investigate the physical properties (temperature, density, and mass) of erupting plasma observed in X-rays and EUV, which are all associated with coronal mass ejections observed by SOHO/LASCO. The erupting plasmas are observed as absorption or emission features in the low corona. The absorption feature provides a lower limit to the cold mass while the emission feature provides an upper limit to the mass of observed plasma in X-ray and EUV. We compare the mass constraints for each temperature response and find that the mass estimates in EUV and XRT are smaller than the total mass in the coronagraph. Several events were observed by a few passbands in the X-rays, which allows us to determine the temperature of the eruptive plasma using a filter ratio method. The temperature of one event is estimated at about 8.6 MK near the top of the erupting plasma. This measurement is possibly an average temperature for higher temperature plasma because the XRT is more sensitive at higher temperatures. In addition, a few events show that the absorption features of a prominence or a loop change to emission features with the beginning of their eruptions in all EUV wavelengths of SDO/AIA, which indicates the heating of the plasma. By estimating the physical properties of the erupting plasmas, we discuss the heating of the plasmas associated with coronal mass ejections in the low corona.

  4. Laboratory Plasma Source as an MHD Model for Astrophysical Jets

    Science.gov (United States)

    Mayo, Robert M.

    1997-01-01

    The significance of the work described herein lies in the demonstration of Magnetized Coaxial Plasma Gun (MCG) devices like CPS-1 to produce energetic laboratory magneto-flows with embedded magnetic fields that can be used as a simulation tool to study flow interaction dynamic of jet flows, to demonstrate the magnetic acceleration and collimation of flows with primarily toroidal fields, and study cross field transport in turbulent accreting flows. Since plasma produced in MCG devices have magnetic topology and MHD flow regime similarity to stellar and extragalactic jets, we expect that careful investigation of these flows in the laboratory will reveal fundamental physical mechanisms influencing astrophysical flows. Discussion in the next section (sec.2) focuses on recent results describing collimation, leading flow surface interaction layers, and turbulent accretion. The primary objectives for a new three year effort would involve the development and deployment of novel electrostatic, magnetic, and visible plasma diagnostic techniques to measure plasma and flow parameters of the CPS-1 device in the flow chamber downstream of the plasma source to study, (1) mass ejection, morphology, and collimation and stability of energetic outflows, (2) the effects of external magnetization on collimation and stability, (3) the interaction of such flows with background neutral gas, the generation of visible emission in such interaction, and effect of neutral clouds on jet flow dynamics, and (4) the cross magnetic field transport of turbulent accreting flows. The applicability of existing laboratory plasma facilities to the study of stellar and extragalactic plasma should be exploited to elucidate underlying physical mechanisms that cannot be ascertained though astrophysical observation, and provide baseline to a wide variety of proposed models, MHD and otherwise. The work proposed herin represents a continued effort on a novel approach in relating laboratory experiments to

  5. Astrophysics of extreme mass ratio inspiral sources

    CERN Document Server

    Hopman, C

    2007-01-01

    Compact remnants on orbits with peri-apses close to the Schwarzschild radius of a massive black hole (MBH) lose orbital energy by emitting gravitational waves (GWs) and spiral in. Scattering with other stars allows successful inspiral of such extreme mass ratio inspiral sources (EMRIs) only within small distances, a < few \\times 0.01 pc from the MBH. The event rate of EMRIs is therefore dominated by the stellar dynamics and content in the inner few \\times 0.01 pc. I discuss the relevant dynamical aspects and resulting estimated event rates of EMRIs. Subjects considered include the loss-cone treatment of inspiral sources; mass segregation; resonant relaxation; and alternative routes to EMRI formation such as tidal binary disruptions, stellar formation in disks and tidal capture of massive main sequence stars. The EMRI event rate is estimated to be of order few \\times 10^2/Gyr per MBH, giving excellent prospects for observation by LISA.

  6. Dense Plasma Focus - From Alternative Fusion Source to Versatile High Energy Density Plasma Source for Plasma Nanotechnology

    Science.gov (United States)

    Rawat, R. S.

    2015-03-01

    The dense plasma focus (DPF), a coaxial plasma gun, utilizes pulsed high current electrical discharge to heat and compress the plasma to very high density and temperature with energy densities in the range of 1-10 × 1010 J/m3. The DPF device has always been in the company of several alternative magnetic fusion devices as it produces intense fusion neutrons. Several experiments conducted on many different DPF devices ranging over several order of storage energy have demonstrated that at higher storage energy the neutron production does not follow I4 scaling laws and deteriorate significantly raising concern about the device's capability and relevance for fusion energy. On the other hand, the high energy density pinch plasma in DPF device makes it a multiple radiation source of ions, electron, soft and hard x-rays, and neutrons, making it useful for several applications in many different fields such as lithography, radiography, imaging, activation analysis, radioisotopes production etc. Being a source of hot dense plasma, strong shockwave, intense energetic beams and radiation, etc, the DPF device, additionally, shows tremendous potential for applications in plasma nanoscience and plasma nanotechnology. In the present paper, the key features of plasma focus device are critically discussed to understand the novelties and opportunities that this device offers in processing and synthesis of nanophase materials using, both, the top-down and bottom-up approach. The results of recent key experimental investigations performed on (i) the processing and modification of bulk target substrates for phase change, surface reconstruction and nanostructurization, (ii) the nanostructurization of PLD grown magnetic thin films, and (iii) direct synthesis of nanostructured (nanowire, nanosheets and nanoflowers) materials using anode target material ablation, ablated plasma and background reactive gas based synthesis and purely gas phase synthesis of various different types of

  7. Element Abundances and Source Plasma Temperatures of Solar Energetic Particles

    Science.gov (United States)

    Reames, Donald V.

    2016-11-01

    Thirty years ago Breneman and Stone [1] observed that the enhancement or suppression of element abundances in large solar energetic-particle (SEP) events varies as a power of the mass-to-charge ratio, A/Q, of the elements. Since Q during acceleration or transport may depend upon the source plasma temperature T, the pattern of element enhancements can provide a best-fit measure of T. The small SEP events we call 3He-rich or “impulsive” show average enhancements, relative to coronal abundances, rising as the 3.6 power of A/Q to a factor of ∼1000 for (76magnetic reconnection on open field lines in solar flares and jets. It has been recently found that the large shock-accelerated “gradual” SEP events have a broad range of source plasma temperatures; 69% have coronal temperatures of T seed population containing residual impulsive suprathermal ions. Most of the large event-to-event abundance variations and their time variation are largely explained by variations in T magnified by A/Q-dependent fractionation during transport. However, the non-thermal variance of impulsive SEP events (∼30%) exceeds that of the ∼3 MK gradual events (∼10%) so that several small impulsive events must be averaged together with the ambient plasma to form the seed population for shock acceleration in these events.

  8. A New Atmospheric Pressure Microwave Plasma Source (APMPS)

    Institute of Scientific and Technical Information of China (English)

    LIU Liang; ZHANG Guixin; LI Yinan; ZHU Zhijie; WANG Xinxin; LUO Chengmu

    2008-01-01

    An atmospheric pressure microwave plasma source (APMPS) that can generate a large volume of plasma at an atmospheric pressure has been developed at Tsinghua University. This paper presents the design of this APMPS, the theoretical consideration of microwave plasma ignition and the simulation results, including the distributions of the electric field and power density inside the cavity as well as the accuracy of the simulation results. In addition, a method of producing an atmospheric pressure microwave plasma and some relevant observations of the plasma are also provided. It. is expected that this research would be useful for further developing atmospheric pressure microwave plasma sources and expanding the scope of their applications.

  9. Potential applications of an electron cyclotron resonance multicusp plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, C.C.; Berry, L.A.; Gorbatkin, S.M.; Haselton, H.H.; Roberto, J.B.; Stirling, W.L. (Oak Ridge National Laboratory, Oak Ridge, TN (USA))

    1990-05-01

    An electron cyclotron resonance (ECR) multicusp plasmatron has been developed by feeding a multicusp bucket arc chamber with a compact ECR plasma source. This novel source produces large (about 25 cm diam), uniform (to within {plus minus}10%), dense ({gt}10{sup 11} cm{sup {minus}3}) plasmas of argon, helium, hydrogen, and oxygen. It has been operated to produce an oxygen plasma for etching 12.7 cm (5 in.) positive photoresist-coated silicon wafers with uniformity within {plus minus}8%. Results and potential applications of this new ECR plasma source for plasma processing of thin films are discussed.

  10. Ions beams and ferroelectric plasma sources

    Science.gov (United States)

    Stepanov, Anton

    Near-perfect space-charge neutralization is required for the transverse compression of high perveance ion beams for ion-beam-driven warm dense matter experiments, such as the Neutralized Drift Compression eXperiment (NDCX). Neutralization can be accomplished by introducing a plasma in the beam path, which provides free electrons that compensate the positive space charge of the ion beam. In this thesis, charge neutralization of a 40 keV, perveance-dominated Ar+ beam by a Ferroelectric Plasma Source (FEPS) is investigated. First, the parameters of the ion beam, such as divergence due to the extraction optics, charge neutralization fraction, and emittance were measured. The ion beam was propagated through the FEPS plasma, and the effects of charge neutralization were inferred from time-resolved measurements of the transverse beam profile. In addition, the dependence of FEPS plasma parameters on the configuration of the driving pulser circuit was studied to optimize pulser design. An ion accelerator was constructed that produced a 30-50 keV Ar + beam with pulse duration angle divergence of 0.87°. The measurements show that near-perfect charge neutralization with FEPS can be attained. No loss of ion beam current was detected, indicating the absence of a neutral cloud in the region of beam propagation, which would cause beam loss to charge exchange collisions. This provides evidence in favor of using FEPS in a future Heavy Ion Fusion accelerator. The FEPS discharge was investigated based on current-voltage measurements in the pulser circuit. Different values of series resistance and storage capacitance in the pulser circuit were used. The charged particle current emitted by the FEPS into vacuum was measured from the difference in forward and return currents in the driving circuit. It was found that FEPS is an emitter of negative charge, and that electron current emission begins approximately 0.5 mus after the fast-rising high voltage pulse is applied and lasts for tens

  11. Spectroscopic characterization of atmospheric pressure um-jet plasma source

    CERN Document Server

    Bibinov, Nikita; Bahre, Hendrik; Awakowicz, Peter; der Gathen, Volker Schulz-von

    2011-01-01

    A radio frequency um-jet plasma source is studied using He/O2 mixture. This um-jet can be used for different applications as a source of chemical active species e.g. oxygen atoms, molecular metastables and ozone. Using absolutely-calibrated optical emission spectroscopy and numerical simulation, the gas temperature in active plasma region and plasma parameters (electron density and electron distribution function) are determined. Concentrations of oxygen atoms and ozone in the plasma channel and in the effluent of the plasma source are measured using emission and absorption spectroscopy. To interpret the measured spatial distributions, the steady-state species' concentrations are calculated using determined plasma parameters and gas temperature. At that the influence of the surface processes and gas flow regime on the loss of the active species in the plasma source are discussed. The measured spatial distributions of oxygen atom and ozone densities are compared with the simulated ones.

  12. Potential applications of an electron cyclotron resonance multicusp plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, C.C.; Berry, L.A.; Gorbatkin, S.M.; Haselton, H.H.; Roberto, J.B.; Schechter, D.E.; Stirling, W.L.

    1990-03-01

    An electric cyclotron resonance (ECR) multicusp plasmatron has been developed by feeding a multicusp bucket arc chamber with a compact ECR plasma source. This novel source produces large (about 25-cm- diam), uniform (to within {plus minus}10%), dense (>10{sup 11}--cm{sup {minus}3}) plasmas of argon, helium, hydrogen, and oxygen. It has been operated to produce an oxygen plasma for etching 12.7-cm (5-in.) positive photoresist-coated silicon wafers with uniformity within {plus minus}8%. Following a brief review of the large plasma source developed at Oak Ridge National Laboratory, the configuration and operation of the source are described and a discharge model is presented. Results from this new ECR plasma source and potential applications for plasma processing of thin films are discussed. 21 refs., 10 figs.

  13. New Applications of Inductively Coupled Plasma-Mass Spectrometry in the Nuclear Industry

    Energy Technology Data Exchange (ETDEWEB)

    Rob Henry; Dagmar Koller; Phil Marriott

    1998-12-31

    Inductively coupled plasma mass spectrometry (ICP-MS) complements the traditional methods of quantitation of radioactive isotopes. Because of the favorable ionization potential of most actinides and their daughter products, the argon plasma provides a rich, stable source of ions, which are introduced through a plasma-mass spectrometer interface into the mass spectrometer for isotopic separation. Samples are normally introduced in solution, although direct solids analysis has also been achieved using laser ablation of the sample into the argon plasma. Since 1983, improvements in ICP-MS sensitivity have resulted in correspondingly lower mass detection capability. This development has in turn expanded the number of isotopes accessible to measurement at the levels required in the nuclear industry.

  14. New high temperature plasmas and sample introduction systems for analytical atomic emission and mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Montaser, A.

    1992-01-01

    New high temperature plasmas and new sample introduction systems are explored for rapid elemental and isotopic analysis of gases, solutions, and solids using mass spectrometry and atomic emission spectrometry. Emphasis was placed on atmospheric pressure He inductively coupled plasmas (ICP) suitable for atomization, excitation, and ionization of elements; simulation and computer modeling of plasma sources with potential for use in spectrochemical analysis; spectroscopic imaging and diagnostic studies of high temperature plasmas, particularly He ICP discharges; and development of new, low-cost sample introduction systems, and examination of techniques for probing the aerosols over a wide range. Refs., 14 figs. (DLC)

  15. Multifunctional bulk plasma source based on discharge with electron injection

    Energy Technology Data Exchange (ETDEWEB)

    Klimov, A. S.; Medovnik, A. V. [Tomsk State University of Control Systems and Radioelectronics, Tomsk 634050 (Russian Federation); Tyunkov, A. V. [Tomsk State University of Control Systems and Radioelectronics, Tomsk 634050 (Russian Federation); Institute of High Current Electronics, Tomsk 634055 (Russian Federation); Savkin, K. P.; Shandrikov, M. V.; Vizir, A. V. [Institute of High Current Electronics, Tomsk 634055 (Russian Federation)

    2013-01-15

    A bulk plasma source, based on a high-current dc glow discharge with electron injection, is described. Electron injection and some special design features of the plasma arc emitter provide a plasma source with very long periods between maintenance down-times and a long overall lifetime. The source uses a sectioned sputter-electrode array with six individual sputter targets, each of which can be independently biased. This discharge assembly configuration provides multifunctional operation, including plasma generation from different gases (argon, nitrogen, oxygen, acetylene) and deposition of composite metal nitride and oxide coatings.

  16. The HelCat dual-source plasma device.

    Science.gov (United States)

    Lynn, Alan G; Gilmore, Mark; Watts, Christopher; Herrea, Janis; Kelly, Ralph; Will, Steve; Xie, Shuangwei; Yan, Lincan; Zhang, Yue

    2009-10-01

    The HelCat (Helicon-Cathode) device has been constructed to support a broad range of basic plasma science experiments relevant to the areas of solar physics, laboratory astrophysics, plasma nonlinear dynamics, and turbulence. These research topics require a relatively large plasma source capable of operating over a broad region of parameter space with a plasma duration up to at least several milliseconds. To achieve these parameters a novel dual-source system was developed utilizing both helicon and thermionic cathode sources. Plasma parameters of n(e) approximately 0.5-50 x 10(18) m(-3) and T(e) approximately 3-12 eV allow access to a wide range of collisionalities important to the research. The HelCat device and initial characterization of plasma behavior during dual-source operation are described.

  17. Antitumor action of non thermal plasma sources, DBD and Plasma Gun, alone or in combined protocols

    Science.gov (United States)

    Robert, Eric; Brullé, Laura; Vandamme, Marc; Riès, Delphine; Le Pape, Alain; Pouvesle, Jean-Michel

    2012-10-01

    The presentation deals with the assessment on two non thermal plasma sources developed and optimized for oncology applications. The first plasma source is a floating-electrode dielectric barrier discharge powered at a few hundreds of Hz which deliver air-plasma directly on the surface of cell culture medium in dishes or on the skin or organs of mice bearing cancer tumors. The second plasma source, so called Plasma Gun, is a plasma jet source triggered in noble gas, transferred in high aspect ratio and flexible capillaries, on targeting cells or tumors after plasma transfer in air through the ``plasma plume'' generated at the capillary outlet. In vitro evidence for massive cancer cell destruction and in vivo tumor activity and growth rate reductions have been measured with both plasma sources. DNA damages, cell cycle arrests and apoptosis induction were also demonstrated following the application of any of the two plasma source both in vitro and in vivo. The comparison of plasma treatment with state of the art chemotherapeutic alternatives has been performed and last but not least the benefit of combined protocols involving plasma and chemotherapeutic treatments has been evidenced for mice bearing orthotopic pancreas cancer and is under evaluation for the colon tumors.

  18. Element Abundances and Source Plasma Temperatures of Solar Energetic Particles

    CERN Document Server

    Reames, Donald V

    2016-01-01

    Thirty years ago Breneman and Stone observed that the enhancement or suppression of element abundances in large solar energetic-particle (SEP) events varies as a power of the mass-to-charge ratio, A/Q, of the elements. Since Q during acceleration or transport may depend upon the source plasma temperature T, the pattern of element enhancements can provide a best-fit measure of T. The small SEP events we call 3He-rich or "impulsive" show average enhancements, relative to coronal abundances, rising as the 3.6 power of A/Q to a factor of ~1000 for (76<=Z<=82)/O and temperature in the range 2-4 MK. This acceleration is believed to occur in islands of magnetic reconnection on open field lines in solar flares and jets. It has been recently found that the large shock-accelerated "gradual" SEP events have a broad range of source plasma temperatures; 69% have coronal temperatures of T < 1.6 MK, while 24% have T ~ 3 MK, the latter suggesting a seed population containing residual impulsive suprathermal ions. Mos...

  19. Ion sampling and transport in Inductively Coupled Plasma Mass Spectrometry

    Science.gov (United States)

    Farnsworth, Paul B.; Spencer, Ross L.

    2017-08-01

    Quantitative accuracy and high sensitivity in inductively coupled plasma mass spectrometry (ICP-MS) depend on consistent and efficient extraction and transport of analyte ions from an inductively coupled plasma to a mass analyzer, where they are sorted and detected. In this review we examine the fundamental physical processes that control ion sampling and transport in ICP-MS and compare the results of theory and computerized models with experimental efforts to characterize the flow of ions through plasma mass spectrometers' vacuum interfaces. We trace the flow of ions from their generation in the plasma, into the sampling cone, through the supersonic expansion in the first vacuum stage, through the skimmer, and into the ion optics that deliver the ions to the mass analyzer. At each stage we consider idealized behavior and departures from ideal behavior that affect the performance of ICP-MS as an analytical tool.

  20. A multifunctional plasma and deposition sensor for the characterization of plasma sources for film deposition and etching

    Science.gov (United States)

    Weise, Michael; Seeger, Stefan; Harbauer, Karsten; Welzel, Thomas; Ellmer, Klaus

    2017-07-01

    Our recently reported multifunctional plasma and deposition sensor [Welzel et al., Appl. Phys. Lett. 102, 211605 (2013)] was used for the characterization of two different plasma sources: a magnetron sputtering deposition source and an ion beam source. The multifunctional sensor, based on a conventional quartz crystal monitor (microbalance) for mass increase/decrease measurements, can measure quasi-simultaneously the deposition/etching flux, the energy flux, and the charged particle flux. By moving the sensor or the plasma source stepwise against each other, the lateral (radial) flux profiles of the different sources can be measured with a lateral resolution of about 8 mm, the diameter of aperture in front of the quartz crystal. It is demonstrated that this compact and simple multifunctional sensor is a versatile tool for the characterization of different kinds of plasma sources for deposition and etching purposes. By combining the different measured quantities, the ion-to-neutral ratio and the mean energy per deposited atom can be calculated, parameters that are essential for the characterization of plasma deposition and etch processes.

  1. Study of electron current extraction from a radio frequency plasma cathode designed as a neutralizer for ion source applications

    Energy Technology Data Exchange (ETDEWEB)

    Jahanbakhsh, Sina, E-mail: sinajahanbakhsh@gmail.com; Satir, Mert; Celik, Murat [Department of Mechanical Engineering, Bogazici University, Istanbul 34342 (Turkey)

    2016-02-15

    Plasma cathodes are insert free devices that are developed to be employed as electron sources in electric propulsion and ion source applications as practical alternatives to more commonly used hollow cathodes. Inductively coupled plasma cathodes, or Radio Frequency (RF) plasma cathodes, are introduced in recent years. Because of its compact geometry, and simple and efficient plasma generation, RF plasma source is considered to be suitable for plasma cathode applications. In this study, numerous RF plasma cathodes have been designed and manufactured. Experimental measurements have been conducted to study the effects of geometric and operational parameters. Experimental results of this study show that the plasma generation and electron extraction characteristics of the RF plasma cathode device strongly depend on the geometric parameters such as chamber diameter, chamber length, orifice diameter, orifice length, as well as the operational parameters such as RF power and gas mass flow rate.

  2. Spatial control of processing plasmas in a multicusp plasma source equipped with a movable magnetic filter

    Energy Technology Data Exchange (ETDEWEB)

    Fukumasa, O.; Naitou, H.; Sakiyama, S. (Yamaguchi Univ., Yamaguchi (Japan))

    1991-12-20

    The plasma chemical vapor deposition (p-CVD) method has been used in the preparation of various sorts of thin films such as hydrogenated amorphous silicon films and hydrogenated amorphous carbon films, etc. and the application feasibility of a magnetically filtered multicusp plasma source has been studied. In this paper, it is confirmed that plasma parameters (H {sub 2} - ch {sub 4} or Ar-CH {sub 4} plasmas) are spatially well controlled by using both a movable magnetic filter and a plasma grid. Plasma parameters change sharply across the magnetic filter at any filter position and the whole plasma is divided clearly into the region of source plasma with high-energy electrons and the region of diffused plasma without high-energy electrons. Concerning the role of the magnetic filter which reflects preferentially high-energy electrons, a study is made through computer simulation. 7 refs., 9 figs.

  3. Capillary plasma jet: A low volume plasma source for life science applications

    Energy Technology Data Exchange (ETDEWEB)

    Topala, I., E-mail: ionut.topala@uaic.ro, E-mail: tmnagat@ipc.shizuoka.ac.jp [Alexandru Ioan Cuza University of Iasi, Faculty of Physics, Iasi Plasma Advanced Research Center (IPARC), Bd. Carol I No. 11, Iasi 700506 (Romania); Nagatsu, M., E-mail: ionut.topala@uaic.ro, E-mail: tmnagat@ipc.shizuoka.ac.jp [Graduate School of Science and Technology, Shizuoka University, 3-5-1 Johoku, Naka-ku, Hamamatsu 432-8561 (Japan)

    2015-02-02

    In this letter, we present results from multispectroscopic analysis of protein films, after exposure to a peculiar plasma source, i.e., the capillary plasma jet. This plasma source is able to generate very small pulsed plasma volumes, in kilohertz range, with characteristic dimensions smaller than 1 mm. This leads to specific microscale generation and transport of all plasma species. Plasma diagnosis was realized using general electrical and optical methods. Depending on power level and exposure duration, this miniature plasma jet can induce controllable modifications to soft matter targets. Detailed discussions on protein film oxidation and chemical etching are supported by results from absorption, X-ray photoelectron spectroscopy, and microscopy techniques. Further exploitation of principles presented here may consolidate research interests involving plasmas in biotechnologies and plasma medicine, especially in patterning technologies, modified biomolecule arrays, and local chemical functionalization.

  4. Plasma-based ambient mass spectrometry techniques: The current status and future prospective.

    Science.gov (United States)

    Ding, Xuelu; Duan, Yixiang

    2015-01-01

    Plasma-based ambient mass spectrometry is emerging as a frontier technology for direct analysis of sample that employs low-energy plasma as the ionization reagent. The versatile sources of ambient mass spectrometry (MS) can be classified according to the plasma formation approaches; namely, corona discharge, glow discharge, dielectric barrier discharge, and microwave-induced discharge. These techniques allow pretreatment-free detection of samples, ranging from biological materials (e.g., flies, bacteria, plants, tissues, peptides, metabolites, and lipids) to pharmaceuticals, food-stuffs, polymers, chemical warfare reagents, and daily-use chemicals. In most cases, plasma-based ambient MS performs well as a qualitative tool and as an analyzer for semi-quantitation. Herein, we provide an overview of the key concepts, mechanisms, and applications of plasma-based ambient MS techniques, and discuss the challenges and outlook.

  5. Source apportionment using reconstructed mass calculations.

    Science.gov (United States)

    Siddique, Naila; Waheed, Shahida

    2014-01-01

    A long-term study was undertaken to investigate the air quality of the Islamabad/Rawalpindi area. In this regard fine and coarse particulate matter were collected from 4 sites in the Islamabad/Rawalpindi region from 1998 to 2010 using Gent samplers and polycarbonate filters and analyzed for their elemental composition using the techniques of Neutron Activation Analysis (NAA), Proton Induced X-ray Emission/Proton Induced Gamma-ray Emission (PIXE/PIGE) and X-ray Fluorescence (XRF) Spectroscopy. The elemental data along with the gravimetric measurements and black carbon (BC) results obtained by reflectance measurement were used to approximate or reconstruct the particulate mass (RCM) by estimation of pseudo sources such as soil, smoke, sea salt, sulfate and black carbon or soot. This simple analysis shows that if the analytical technique used does not measure important major elements then the data will not be representative of the sample composition and cannot be further utilized for source apportionment studies or to perform transboundary analysis. In this regard PIXE/PIGE and XRF techniques that can provide elemental compositional data for most of the major environmentally important elements appear to be more useful as compared to NAA. Therefore %RCM calculations for such datasets can be used as a quality assurance (QA) measure to treat data prior to application of chemometrical tools such as factor analysis (FA) or cluster analysis (CA).

  6. Cysteine as a Biological Probe for Comparing Plasma Sources

    Science.gov (United States)

    Lackmann, Jan-Wilm; Golda, Judith; Kogelheide, Friederike; Held, Julian; Schulz-von-der-Gathen, Volker; Stapelmann, Katharina

    2016-09-01

    A large variety of plasma sources are available in the plasma medicine community. While enabling to choose the most promising source for a certain biomedical application, comparison of the different sources with a focus on their effect on biological targets is rather challenging. To allow for better comparison of various sources, the recent European COST action MP1101 was used to design the COST reference microplasma jet. Cysteine is a promising candidate investigate the impact of plasma from various sources on a standardized biological molecule, which is especially relevant for the investigations on a molecular level after plasma treatment. The simple structure of cysteine allows for a more in-depth analysis of each chemical group after plasma treatment and enables a comparison between different plasma sources and treatment parameters on each chemical group. The model itself has already been successfully established using a dielectric barrier discharge. Here, additional plasma sources are compared by the means of their impact on cysteine samples, showing e.g. the influence of feed-gas variations by adding oxygen or nitrogen admixture This work was supported by the German Research Foundation (DFG) with the packet grant PAK816 (PlaCID).

  7. Shunting arc plasma source for pure carbon ion beam.

    Science.gov (United States)

    Koguchi, H; Sakakita, H; Kiyama, S; Shimada, T; Sato, Y; Hirano, Y

    2012-02-01

    A plasma source is developed using a coaxial shunting arc plasma gun to extract a pure carbon ion beam. The pure carbon ion beam is a new type of deposition system for diamond and other carbon materials. Our plasma device generates pure carbon plasma from solid-state carbon material without using a hydrocarbon gas such as methane gas, and the plasma does not contain any hydrogen. The ion saturation current of the discharge measured by a double probe is about 0.2 mA∕mm(2) at the peak of the pulse.

  8. Shunting arc plasma source for pure carbon ion beama)

    Science.gov (United States)

    Koguchi, H.; Sakakita, H.; Kiyama, S.; Shimada, T.; Sato, Y.; Hirano, Y.

    2012-02-01

    A plasma source is developed using a coaxial shunting arc plasma gun to extract a pure carbon ion beam. The pure carbon ion beam is a new type of deposition system for diamond and other carbon materials. Our plasma device generates pure carbon plasma from solid-state carbon material without using a hydrocarbon gas such as methane gas, and the plasma does not contain any hydrogen. The ion saturation current of the discharge measured by a double probe is about 0.2 mA/mm2 at the peak of the pulse.

  9. Catheterized plasma X-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Derzon, Mark S.; Robinson, Alex; Galambos, Paul C.

    2017-06-20

    A radiation generator useful for medical applications, among others, is provided. The radiation generator includes a catheter; a plasma discharge chamber situated within a terminal portion of the catheter, a cathode and an anode positioned within the plasma discharge chamber and separated by a gap, and a high-voltage transmission line extensive through the interior of the catheter and terminating on the cathode and anode so as to deliver, in operation, one or more voltage pulses across the gap.

  10. Matrix effects in inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Xiaoshan [Iowa State Univ., Ames, IA (United States)

    1995-07-07

    The inductively coupled plasma is an electrodeless discharge in a gas (usually Ar) at atmospheric pressure. Radio frequency energy generated by a RF power source is inductively coupled to the plasma gas through a water cooled load coil. In ICP-MS the "Fassel" TAX quartz torch commonly used in emission is mounted horizontally. The sample aerosol is introduced into the central flow, where the gas kinetic temperature is about 5000 K. The aerosol is vaporized, atomized, excited and ionized in the plasma, and the ions are subsequently extracted through two metal apertures (sampler and skimmer) into the mass spectrometer. In ICP-MS, the matrix effects, or non-spectroscopic interferences, can be defined as the type of interferences caused by dissolved concomitant salt ions in the solution. Matrix effects can be divided into two categories: (1) signal drift due to the deposition of solids on the sampling apertures; and/or (2) signal suppression or enhancement by the presence of the dissolved salts. The first category is now reasonably understood. The dissolved salts, especially refractory oxides, tend to deposit on the cool tip of the sampling cone. The clogging of the orifices reduces the ion flow into the ICP-MS, lowers the pressure in the first stage of ICP-MS, and enhances the level of metal oxide ions. Because the extent of the clogging increases with the time, the signal drifts down. Even at the very early stage of the development of ICP-MS, matrix effects had been observed. Houk et al. found out that the ICP-MS was not tolerant to solutions containing significant amounts of dissolved solids.

  11. Physical limitations in ferromagnetic inductively coupled plasma sources

    CERN Document Server

    Bliokh, Yury P; Slutsker, Yakov Z

    2012-01-01

    The Ferromagnetic Inductively Coupled Plasma (FICP) source, which is a version of the common inductively coupled plasma sources, has a number of well known advantages such as high efficiency, high level of ionization, low minimal gas pressure, very low required driver frequency, and even a possibility to be driven by single current pulses. We present an experimental study of such an FICP source which showed that above a certain value of the driving pulse power the properties of this device changed rather drastically. Namely, the plasma became non-stationary and non-uniform contrary to the stationary and uniform plasmas typical for this kind of plasma sources. In this case the plasma appeared as a narrow dense spike which was short compared to the driving pulse. The local plasma density could exceed the neutral atoms density by a few orders of magnitude. When that happened, the afterglow plasma decay time after the end of the pulse was long compared to an ordinary case with no plasma spike. Experiments were pe...

  12. Counter-facing plasma guns for efficient extreme ultra-violet plasma light source

    Science.gov (United States)

    Kuroda, Yusuke; Yamamoto, Akiko; Kuwabara, Hajime; Nakajima, Mitsuo; Kawamura, Tohru; Horioka, Kazuhiko

    2013-11-01

    A plasma focus system composed of a pair of counter-facing coaxial guns was proposed as a long-pulse and/or repetitive high energy density plasma source. We applied Li as the source of plasma for improvement of the conversion efficiency, the spectral purity, and the repetition capability. For operation of the system with ideal counter-facing plasma focus mode, we changed the system from simple coaxial geometry to a multi-channel configuration. We applied a laser trigger to make synchronous multi-channel discharges with low jitter. The results indicated that the configuration is promising to make a high energy density plasma with high spectral efficiency.

  13. Ferroelectric Plasma Source for Heavy Ion Beam Charge Neutralization

    CERN Document Server

    Efthimion, Philip; Gilson, Erik P; Grisham, Larry; Logan, B G; Waldron, William; Yu, Simon

    2005-01-01

    Plasmas are employed as a medium for charge neutralizing heavy ion beams to allow them to focus to a small spot size. Calculations suggest that plasma at a density of 1-100 times the ion beam density and at a length ~ 0.1-1 m would be suitable. To produce 1 meter plasma, large-volume plasma sources based upon ferroelectric ceramics are being considered. These sources have the advantage of being able to increase the length of the plasma and operate at low neutral pressures. The source will utilize the ferroelectric ceramic BaTiO3 to form metal plasma. The drift tube inner surface of the Neutralized Drift Compression Experiment (NDCX) will be covered with ceramic. High voltage (~ 1-5 kV) is applied between the drift tube and the front surface of the ceramic by placing a wire grid on the front surface. A prototype ferroelectric source 20 cm long produced plasma densities ~ 5x1011 cm-3. The source was integrated into the experiment and successfully charge neutralized the K ion beam. Presently, the 1 meter source ...

  14. Design and Construction of a Microwave Plasma Ion Source

    CERN Document Server

    Çınar, Kamil

    2011-01-01

    This thesis is about the designing and constructing a microwave ion source. The ions are generated in a thermal and dense hydrogen plasma by microwave induction. The plasma is generated by using a microwave source with a frequency of 2.45 GHz and a power of 700 W. The generated microwave is pulsing with a frequency of 50 Hz. The designed and constructed microwave system generates hydrogen plasma in a pyrex plasma chamber. Moreover, an ion extraction unit is designed and constructed in order to extract the ions from the generated hydrogen plasma. The ion beam extraction is achieved and ion currents are measured. The plasma parameters are determined by a double Langmuir probe and the ion current is measured by a Faraday cup. The designed ion extraction unit is simulated by using the dimensions of the designed and constructed ion extraction unit in order to trace out the trajectories of the extracted ions.

  15. Determination of iodine at ppt level in a nitric acid medium by inductively coupled plasma sector field mass spectrometry: influence of the chemical forms; Etude de la determination de traces d'iode en solution par spectrometrie de masse a secteur magnetique utilisant un plasma a couplage inductif comme source d'ionisation: influence de la forme chimique

    Energy Technology Data Exchange (ETDEWEB)

    Langlois, B

    2001-07-01

    Inductively Coupled Plasma Sector Field Mass Spectrometry (ICP/SFMS) was used to determine several chemical forms of iodine, at ppt level, in a nitric acid media. Ascorbic acid was added as a reducing agent in order to maintain iodine as iodide. In a preliminary approach, the influence of the chemical form was studied by comparing inorganic iodine (NaI) and organic iodine (CH3I). Different signal responses were observed. With a conventional sample introduction system, sensitivities obtained for iodo-methane could differ by a factor of 5. This was not caused by a problem of atomization or by a change in the ionization efficiency of the iodo-compound into the plasma. The low volatilization temperature of iodo-methane (315.5 K) seemed to be the main explanation of this phenomena. Actually, nebulization resulted in the volatilization of a 2% nitric acid solution containing iodo-methane. As a result, the transport efficiency of iodo-methane between the nebulizer and the torch was approaching 100%. A Direct Injection High Efficiency Nebulizer (DIHEN) allowed us to minimize the behavior difference between the two iodine species, but the sensitivity ratio was inverted and still differed by 20 - 40%. Moreover, the association of a guard electrode and the direct injection system was studied in order to apply these equipments to the determination of iodine. This association allowed us to improve the sensitivity by a factor of 10 and to minimize memory effects, when compared with a conventional system. Further studies indicated that signal responses obtained with different iodine-containing species, except for iodo-methane, were found to be similar. (author)

  16. Physical investigation of a quad confinement plasma source

    Science.gov (United States)

    Knoll, Aaron; Lucca Fabris, Andrea; Young, Christopher; Cappelli, Mark

    2016-10-01

    Quad magnetic confinement plasma sources are novel magnetized DC discharges suitable for applications in a broad range of fields, particularly space propulsion, plasma etching and deposition. These sources contain a square discharge channel with magnetic cusps at the four lateral walls, enhancing plasma confinement and electron residence time inside the device. The magnetic field topology is manipulated using four independent electromagnets on each edge of the channel, tuning the properties of the generated plasma. We characterize the plasma ejected from the quad confinement sources using a combination of traditional electrostatic probes and non-intrusive laser-based diagnostics. Measurements show a strong ion acceleration layer located 8 cm downstream of the exit plane, beyond the extent of the magnetic field. The ion velocity field is investigated with different magnetic configurations, demonstrating how ion trajectories may be manipulated. C.Y. acknowledges support from the DOE NSSA Stewardship Science Graduate Fellowship under contract DE-FC52-08NA28752.

  17. Modeling of low pressure plasma sources for microelectronics fabrication

    Science.gov (United States)

    Agarwal, Ankur; Bera, Kallol; Kenney, Jason; Likhanskii, Alexandre; Rauf, Shahid

    2017-10-01

    Chemically reactive plasmas operating in the 1 mTorr–10 Torr pressure range are widely used for thin film processing in the semiconductor industry. Plasma modeling has come to play an important role in the design of these plasma processing systems. A number of 3-dimensional (3D) fluid and hybrid plasma modeling examples are used to illustrate the role of computational investigations in design of plasma processing hardware for applications such as ion implantation, deposition, and etching. A model for a rectangular inductively coupled plasma (ICP) source is described, which is employed as an ion source for ion implantation. It is shown that gas pressure strongly influences ion flux uniformity, which is determined by the balance between the location of plasma production and diffusion. The effect of chamber dimensions on plasma uniformity in a rectangular capacitively coupled plasma (CCP) is examined using an electromagnetic plasma model. Due to high pressure and small gap in this system, plasma uniformity is found to be primarily determined by the electric field profile in the sheath/pre-sheath region. A 3D model is utilized to investigate the confinement properties of a mesh in a cylindrical CCP. Results highlight the role of hole topology and size on the formation of localized hot-spots. A 3D electromagnetic plasma model for a cylindrical ICP is used to study inductive versus capacitive power coupling and how placement of ground return wires influences it. Finally, a 3D hybrid plasma model for an electron beam generated magnetized plasma is used to understand the role of reactor geometry on plasma uniformity in the presence of E  ×  B drift.

  18. High electronegativity multi-dipolar electron cyclotron resonance plasma source for etching by negative ions

    DEFF Research Database (Denmark)

    Stamate, Eugen; Draghici, M.

    2012-01-01

    A large area plasma source based on 12 multi-dipolar ECR plasma cells arranged in a 3 x 4 matrix configuration was built and optimized for silicon etching by negative ions. The density ratio of negative ions to electrons has exceeded 300 in Ar/SF6 gas mixture when a magnetic filter was used...... to reduce the electron temperature to about 1.2 eV. Mass spectrometry and electrostatic probe were used for plasma diagnostics. The new source is free of density jumps and instabilities and shows a very good stability for plasma potential, and the dominant negative ion species is F-. The magnetic field...... in plasma volume is negligible and there is no contamination by filaments. The etching rate by negative ions measured in Ar/SF6/O-2 mixtures was almost similar with that by positive ions reaching 700 nm/min. (C) 2012 American Institute of Physics...

  19. Laser Plasma Particle Accelerators: Large Fields for Smaller Facility Sources

    Energy Technology Data Exchange (ETDEWEB)

    Geddes, Cameron G.R.; Cormier-Michel, Estelle; Esarey, Eric H.; Schroeder, Carl B.; Vay, Jean-Luc; Leemans, Wim P.; Bruhwiler, David L.; Cary, John R.; Cowan, Ben; Durant, Marc; Hamill, Paul; Messmer, Peter; Mullowney, Paul; Nieter, Chet; Paul, Kevin; Shasharina, Svetlana; Veitzer, Seth; Weber, Gunther; Rubel, Oliver; Ushizima, Daniela; Bethel, Wes; Wu, John

    2009-03-20

    Compared to conventional particle accelerators, plasmas can sustain accelerating fields that are thousands of times higher. To exploit this ability, massively parallel SciDAC particle simulations provide physical insight into the development of next-generation accelerators that use laser-driven plasma waves. These plasma-based accelerators offer a path to more compact, ultra-fast particle and radiation sources for probing the subatomic world, for studying new materials and new technologies, and for medical applications.

  20. Laser-Produced Plasmas and Radiation Sources.

    Science.gov (United States)

    1980-01-31

    Vlases, H. Rutkowski, A. Hertzberg, A. Hoffman, L. Steinhauer, J. Dawson, D.R. Cohn, W. Halverson, B. Lax, J.D. Daugherty, J.E. Eninger , E.R. Pugh, T.K...Meeting, Albuquerque (October 1974). J.D. Daugherty, J.E. Eninger , D.R. Cohn, and W. Halverson, "Scaling of Laser Heated Plasmas Confined in Long Solenoids...Cohn, H.E. Eninger , W. Halverson, and D.J. Rose, "Stress, Dissipation, and Neutronics Constraints on ’fagnets for Laser-Solenoid Reactors," APS Plasma

  1. Matching network for RF plasma source

    Science.gov (United States)

    Pickard, Daniel S.; Leung, Ka-Ngo

    2007-11-20

    A compact matching network couples an RF power supply to an RF antenna in a plasma generator. The simple and compact impedance matching network matches the plasma load to the impedance of a coaxial transmission line and the output impedance of an RF amplifier at radio frequencies. The matching network is formed of a resonantly tuned circuit formed of a variable capacitor and an inductor in a series resonance configuration, and a ferrite core transformer coupled to the resonantly tuned circuit. This matching network is compact enough to fit in existing compact focused ion beam systems.

  2. Studies on plasma production in a large volume system using multiple compact ECR plasma sources

    Science.gov (United States)

    Tarey, R. D.; Ganguli, A.; Sahu, D.; Narayanan, R.; Arora, N.

    2017-01-01

    This paper presents a scheme for large volume plasma production using multiple highly portable compact ECR plasma sources (CEPS) (Ganguli et al 2016 Plasma Source Sci. Technol. 25 025026). The large volume plasma system (LVPS) described in the paper is a scalable, cylindrical vessel of diameter  ≈1 m, consisting of source and spacer sections with multiple CEPS mounted symmetrically on the periphery of the source sections. Scaling is achieved by altering the number of source sections/the number of sources in a source section or changing the number of spacer sections for adjusting the spacing between the source sections. A series of plasma characterization experiments using argon gas were conducted on the LVPS under different configurations of CEPS, source and spacer sections, for an operating pressure in the range 0.5-20 mTorr, and a microwave power level in the range 400-500 W per source. Using Langmuir probes (LP), it was possible to show that the plasma density (~1  -  2  ×  1011 cm-3) remains fairly uniform inside the system and decreases marginally close to the chamber wall, and this uniformity increases with an increase in the number of sources. It was seen that a warm electron population (60-80 eV) is always present and is about 0.1% of the bulk plasma density. The mechanism of plasma production is discussed in light of the results obtained for a single CEPS (Ganguli et al 2016 Plasma Source Sci. Technol. 25 025026).

  3. Rare-earth plasma light source for VUV applications.

    Science.gov (United States)

    O'Sullivan, G; Carroll, P K; McLlrath, T J; Ginter, M L

    1981-09-01

    A compact versatile light source for producing VUV radiation from laser produced plasmas is described. Measurements of the spectral irradiance from CO(2) laser-produced plasmas on targets of gadolinium and ytterbium in the 115-220-nm range are given, and a comparison is made with analogous results obtained using a ruby laser.

  4. Modelling the plasma plume of an assist source in PIAD

    Science.gov (United States)

    Wauer, Jochen; Harhausen, Jens; Foest, Rüdiger; Loffhagen, Detlef

    2016-09-01

    Plasma ion assisted deposition (PIAD) is a technique commonly used to produce high-precision optical interference coatings. Knowledge regarding plasma properties is most often limited to dedicated scenarios without film deposition. Approaches have been made to gather information on the process plasma in situ to detect drifts which are suspected to cause limits in repeatability of resulting layer properties. Present efforts focus on radiance monitoring of the plasma plume of an Advanced Plasma Source (APSpro, Bühler) by optical emission spectroscopy to provide the basis for an advanced plasma control. In this contribution modelling results of the plume region are presented to interpret these experimental data. In the framework of the collisional radiative model used, 15 excited neutral argon states in the plasma are considered. Results of the species densities show good consistency with the measured optical emission of various argon 2 p - 1 s transitions. This work was funded by BMBF under grant 13N13213.

  5. A Plasma Ion Source for ISOLTRAP

    CERN Document Server

    Skov, Thomas Guldager

    2016-01-01

    In this report, my work testing the new Penning ion source as a summer student at ISOLTRAP is described. The project was composed of three stages: (1) Setting up a test laboratory in building 275, (2) characterizing the ion source, and (3) implementing and testing the source in the ISOLTRAP setup. After setting up the test laboratory, the ion source was tested in a constant pressure environment with produced ion currents in the range of nA . An extensive scan of the source ion current versus operating parameters (pressure, voltage) was performed. A setup with pulsed gas flow was also tested, allowing a reduction of the gas load on the vacuum system. The behavior of the ion source together with the ISOLTRAP setup was also investigated, allowing to understand current limitations and future directions of improvement.

  6. The coupling of capillary electrophoresis-inductively coupled plasma mass spectrometer as a speciation instrument for actinides at trace level; Le couplage electrophorese capillaire-spectrometre de masse a source plasma en tant qu'instrument de speciation des actinides a l'etat de traces

    Energy Technology Data Exchange (ETDEWEB)

    Delorme, A

    2004-07-01

    An interface between the separation technique (capillary electrophoresis) and the analytical technique (Inductively Coupled Plasma - Mass Spectrometer) was developed. In that sense, bibliographic and parametric studies allowed to define necessary conditions for the good working of both techniques. The results obtained led to the realisation of an interface capillary electrophoresis / ICP-MS (CE / ICP-MS). This one was experimentally validated on classical separations (alkalis / earth-alkalis and lanthanides) and the detection limit of the analytical system was determined equal to 4 x 10{sup -11} mol.L{sup -1} for plutonium. This result exhibits a gain in detection limit of a factor higher than 10{sup 4} compared to the capillary electrophoresis in standard detection (UV). The studies were made in order to check the capacity of the CE / ICP-MS coupling as a speciation instrument for actinides at trace level and to define the associated analytical procedures. The coupling turned out to be a suited instrument for the determination of absolute electrophoretic mobilities at infinite dilution (physico-chemical property which allows to predict the migration time of an ion under an electrical field in a given electrolyte), for the determination of thermodynamic constants and for the separation of different actinide oxidation states in solution. (author)

  7. Multicapillary cathode controlled by a ferroelectric plasma source

    Science.gov (United States)

    Gleizer, J. Z.; Hadas, Y.; Krasik, Ya. E.

    2008-06-01

    We present results of high-current microsecond and sub-microsecond duration electron beam generation in a ~200 kV diode with a multicapillary dielectric cathode (MCDC) assisted by a ferroelectric plasma source (FPS). Electron beam current densities are achieved up to 40 A/cm2. It was shown that the operation of the MCDC is determined by the parameters of the plasma flow generated by the FPS. Also, it was found that the high resistivity of the plasma produced inside the capillaries allows effective de-coupling of individual capillary plasma discharges which results in uniform electron beam generation.

  8. Characteristics of Cylindrical Microwave Plasma Source at Low Pressure

    Science.gov (United States)

    Park, Seungil; Youn, S.; Kim, S. B.; Yoo, S. J.

    2016-10-01

    A microwave plasma source with a cylindrical resonance cavity has been proposed to generate the plasma at low pressure. This plasma source consists of magnetron, waveguide, antenna, and cavity. The microwave generating device is a commercial magnetron with 1 kW output power at the frequency of 2.45 GHz. The microwave is transmitted through the rectangular waveguide with the whistle shape, and coupled to the cavity by the slot antenna. The resonant mode of the cylindrical cavity is the TE111 mode. The operating pressure is between 0.1 Torr and 0.3 Torr with the Argon and nitrogen gas. The electron temperature and electron number density of argon plasma were measured with the optical emission spectroscopy measurement. And Ar1s5 metastable density was measured using tunable diode laser absorption spectroscopy (TDLAS). The plasma diagnostic results of a cylindrical microwave plasma source would be described in this study. This work was supported by R&D Program of ``Plasma Advanced Technology for Agriculture and Food (Plasma Farming)'' through the National Fusion Research Institute of Korea (NFRI) funded by the Government funds.

  9. Alternative modeling methods for plasma-based Rf ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Veitzer, Seth A., E-mail: veitzer@txcorp.com; Kundrapu, Madhusudhan, E-mail: madhusnk@txcorp.com; Stoltz, Peter H., E-mail: phstoltz@txcorp.com; Beckwith, Kristian R. C., E-mail: beckwith@txcorp.com [Tech-X Corporation, Boulder, Colorado 80303 (United States)

    2016-02-15

    Rf-driven ion sources for accelerators and many industrial applications benefit from detailed numerical modeling and simulation of plasma characteristics. For instance, modeling of the Spallation Neutron Source (SNS) internal antenna H{sup −} source has indicated that a large plasma velocity is induced near bends in the antenna where structural failures are often observed. This could lead to improved designs and ion source performance based on simulation and modeling. However, there are significant separations of time and spatial scales inherent to Rf-driven plasma ion sources, which makes it difficult to model ion sources with explicit, kinetic Particle-In-Cell (PIC) simulation codes. In particular, if both electron and ion motions are to be explicitly modeled, then the simulation time step must be very small, and total simulation times must be large enough to capture the evolution of the plasma ions, as well as extending over many Rf periods. Additional physics processes such as plasma chemistry and surface effects such as secondary electron emission increase the computational requirements in such a way that even fully parallel explicit PIC models cannot be used. One alternative method is to develop fluid-based codes coupled with electromagnetics in order to model ion sources. Time-domain fluid models can simulate plasma evolution, plasma chemistry, and surface physics models with reasonable computational resources by not explicitly resolving electron motions, which thereby leads to an increase in the time step. This is achieved by solving fluid motions coupled with electromagnetics using reduced-physics models, such as single-temperature magnetohydrodynamics (MHD), extended, gas dynamic, and Hall MHD, and two-fluid MHD models. We show recent results on modeling the internal antenna H{sup −} ion source for the SNS at Oak Ridge National Laboratory using the fluid plasma modeling code USim. We compare demonstrate plasma temperature equilibration in two

  10. Alternative modeling methods for plasma-based Rf ion sources

    Science.gov (United States)

    Veitzer, Seth A.; Kundrapu, Madhusudhan; Stoltz, Peter H.; Beckwith, Kristian R. C.

    2016-02-01

    Rf-driven ion sources for accelerators and many industrial applications benefit from detailed numerical modeling and simulation of plasma characteristics. For instance, modeling of the Spallation Neutron Source (SNS) internal antenna H- source has indicated that a large plasma velocity is induced near bends in the antenna where structural failures are often observed. This could lead to improved designs and ion source performance based on simulation and modeling. However, there are significant separations of time and spatial scales inherent to Rf-driven plasma ion sources, which makes it difficult to model ion sources with explicit, kinetic Particle-In-Cell (PIC) simulation codes. In particular, if both electron and ion motions are to be explicitly modeled, then the simulation time step must be very small, and total simulation times must be large enough to capture the evolution of the plasma ions, as well as extending over many Rf periods. Additional physics processes such as plasma chemistry and surface effects such as secondary electron emission increase the computational requirements in such a way that even fully parallel explicit PIC models cannot be used. One alternative method is to develop fluid-based codes coupled with electromagnetics in order to model ion sources. Time-domain fluid models can simulate plasma evolution, plasma chemistry, and surface physics models with reasonable computational resources by not explicitly resolving electron motions, which thereby leads to an increase in the time step. This is achieved by solving fluid motions coupled with electromagnetics using reduced-physics models, such as single-temperature magnetohydrodynamics (MHD), extended, gas dynamic, and Hall MHD, and two-fluid MHD models. We show recent results on modeling the internal antenna H- ion source for the SNS at Oak Ridge National Laboratory using the fluid plasma modeling code USim. We compare demonstrate plasma temperature equilibration in two-temperature MHD models

  11. Inertial Electrostatic Confinement (IEC) Fusion using Helicon Injected Plasma Source

    Science.gov (United States)

    Miley, George; Ahern, Drew; Bowman, Jaerd

    2016-10-01

    The use of an external plasma source with the IEC has the advantage that the background pressure in the IEC chamber can be low. This then enables a deep potential well formation for ion confinement. Also unit efficiency is increase due to minimization of ion losses through charge exchange. This technique is under study experimentally for use in a plasma jet propulsion unit and as an IEC type neutron source. Current work has studied the effect of locating the IEC grids off-center in the vacuum chamber, near the plasma entrance from the Helicon. With double grids, the relative potentials employed are also key factors in device performance. Electron emitters are added for space charge neutralization in the case of plasma jet propulsion. Plasma simulations are used to supplement the experiments. Specifically, the electric field and the magnetic field effects on energetic ion trajectories are examined for varying configurations. Funding by NASA, Air Force Research Lab and NPL Associates.

  12. Combined Gas-Liquid Plasma Source for Nanoparticle Synthesis

    Science.gov (United States)

    Burakov, V. S.; Kiris, V. V.; Nevar, A. A.; Nedelko, M. I.; Tarasenko, N. V.

    2016-09-01

    A gas-liquid plasma source for the synthesis of colloidal nanoparticles by spark erosion of the electrode material was developed and allowed the particle synthesis regime to be varied over a wide range. The source parameters were analyzed in detail for the electrical discharge conditions in water. The temperature, particle concentration, and pressure in the discharge plasma were estimated based on spectroscopic analysis of the plasma. It was found that the plasma parameters did not change signifi cantly if the condenser capacitance was increased from 5 to 20 nF. Purging the electrode gap with argon reduced substantially the pressure and particle concentration. Signifi cant amounts of water decomposition products in addition to electrode elements were found in the plasma in all discharge regimes. This favored the synthesis of oxide nanoparticles.

  13. Abatement of Perfluorinated Compounds Using Cylindrical Microwave Plasma Source at Low Pressure

    Science.gov (United States)

    Kim, Seong Bong; Park, S.; Park, Y.; Youn, S.; Yoo, S. J.

    2016-10-01

    Microwave plasma source with a cylindrical cavity has been proposed to abate the perfluorinated compounds (PFCs). This plasma source was designed to generate microwave plasma with the cylindrical shape and to be easily installed in existing exhaust line. The microwave frequency is 2.45 GHz and the operating pressure range is 0.1 Torr to 0.3 Torr. The plasma characteristic of the cylindrical microwave plasma source was measured using the optical spectrometer, and tunable diode laser absorption spectroscopy (TDLAS). The destruction and removal efficiency (DRE) of CF4 and CHF3 were measured by a quadrupole mass spectroscopy (QMS) with the various operation conditions. The effect of the addition of the oxygen gas were tested and also the correlation between the plasma parameters and the DRE are presented in this study. This work was supported by R&D Program of ``Plasma Advanced Technology for Agriculture and Food (Plasma Farming)'' through the National Fusion Research Institute of Korea (NFRI) funded by the Government funds.

  14. Plasma Viscosity with Mass Transport in Spherical ICF Implosion Simulations

    CERN Document Server

    Vold, Erik L; Ortega, Mario I; Moll, Ryan; Fenn, Daniel; Molvig, Kim

    2015-01-01

    The effects of viscosity and small-scale atomic-level mixing on plasmas in inertial confinement fusion (ICF) currently represent challenges in ICF research. Many current ICF hydrodynamic codes ignore the effects of viscosity though recent research indicates viscosity and mixing by classical transport processes may have a substantial impact on implosion dynamics. We have implemented a Lagrange hydrodynamic code in one-dimensional spherical geometry with plasma viscosity and mass transport and including a three temperature model for ions, electrons, and radiation treated in a gray radiation diffusion approximation. The code is used to study ICF implosion differences with and without plasma viscosity and to determine the impacts of viscosity on temperature histories and neutron yield. It was found that plasma viscosity has substantial impacts on ICF shock dynamics characterized by shock burn timing, maximum burn temperatures, convergence ratio, and time history of neutron production rates. Plasma viscosity reduc...

  15. Fullerene-rare gas mixed plasmas in an electron cyclotron resonance ion source

    CERN Document Server

    Asaji, T; Uchida, T; Minezaki, H; Ishihara, S; Racz, R; Muramatsu, M; Biri, S; Kitagawa, A; Kato, Y; Yoshida, Y

    2015-01-01

    A synthesis technology of endohedral fullerenes such as Fe@C60 has developed with an electron cyclotron resonance (ECR) ion source. The production of N@C60 was reported. However, the yield was quite low, since most fullerene molecules were broken in the ECR plasma. We have adopted gas-mixing techniques in order to cool the plasma and then reduce fullerene dissociation. Mass spectra of ion beams extracted from fullerene-He, Ar or Xe mixed plasmas were observed with a Faraday cup. From the results, the He gas mixing technique is effective against fullerene destruction.

  16. 77 FR 6463 - Revisions to Labeling Requirements for Blood and Blood Components, Including Source Plasma...

    Science.gov (United States)

    2012-02-08

    ... Requirements for Blood and Blood Components, Including Source Plasma; Correction AGENCY: Food and Drug... Blood Components, Including Source Plasma,'' which provided incorrect publication information...

  17. Development of a long-slot microwave plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Kuwata, Y., E-mail: euo1304@mail4.doshisha.ac.jp; Kasuya, T.; Miyamoto, N.; Wada, M. [Graduate School of Science and Engineering, Doshisha University, Kyotanabe, Kyoto 610-0321 (Japan)

    2016-02-15

    A 20 cm long 10 cm wide microwave plasma source was realized by inserting two 20 cm long 1.5 mm diameter rod antennas into the plasma. Plasma luminous distributions around the antennas were changed by magnetic field arrangement created by permanent magnets attached to the source. The distributions appeared homogeneous in one direction along the antenna when the spacing between the antenna and the source wall was 7.5 mm for the input microwave frequency of 2.45 GHz. Plasma density and temperature at a plane 20 cm downstream from the microwave shield were measured by a Langmuir probe array at 150 W microwave power input. The measured electron density and temperature varied over space from 3.0 × 10{sup 9} cm{sup −3} to 5.8 × 10{sup 9} cm{sup −3}, and from 1.1 eV to 2.1 eV, respectively.

  18. Multicomponent Consideration of Electron Fraction of ECR Source Plasma

    CERN Document Server

    Shirkov, G D

    1999-01-01

    The development of physical model and mathematical simulation methods of electron and ion accumulation and production in the ECR ion source is presented. New equations represent electrons in the ECR plasma as a multicomponent media. In the result any kind of experimental or analytical electron distribution function can be approximated with a series of Maxwellian distributions with different temperatures and partial weights. Main positive plasma potential is introduced into consideration in addition to the negative potential dip for highly charged ion confinement. This potential regulates the loss rate of primary cold electrons from the plasma volume and completes the total picture of ECR plasma behavior. The first test of new model and code with recent experimental data of RIKEN 18 GHz ECR source has shown some new opportunities for investigators to study the ECR ion sources.

  19. Imaging thermal plasma mass and velocity analyzer

    Science.gov (United States)

    Yau, Andrew W.; Howarth, Andrew

    2016-07-01

    We present the design and principle of operation of the imaging ion mass and velocity analyzer on the Enhanced Polar Outflow Probe (e-POP), which measures low-energy (1-90 eV/e) ion mass composition (1-40 AMU/e) and velocity distributions using a hemispherical electrostatic analyzer (HEA), a time-of-flight (TOF) gate, and a pair of toroidal electrostatic deflectors (TED). The HEA and TOF gate measure the energy-per-charge and azimuth of each detected ion and the ion transit time inside the analyzer, respectively, providing the 2-D velocity distribution of each major ionospheric ion species and resolving the minor ion species under favorable conditions. The TED are in front of the TOF gate and optionally sample ions at different elevation angles up to ±60°, for measurement of 3-D velocity distribution. We present examples of observation data to illustrate the measurement capability of the analyzer, and show the occurrence of enhanced densities of heavy "minor" O++, N+, and molecular ions and intermittent, high-velocity (a few km/s) upward and downward flowing H+ ions in localized regions of the quiet time topside high-latitude ionosphere.

  20. Comparing Jupiter and Saturn: dimensionless input rates from plasma sources within the magnetosphere

    Directory of Open Access Journals (Sweden)

    V. M. Vasyliūnas

    2008-06-01

    Full Text Available The quantitative significance for a planetary magnetosphere of plasma sources associated with a moon of the planet can be assessed only by expressing the plasma mass input rate in dimensionless form, as the ratio of the actual mass input to some reference value. Traditionally, the solar wind mass flux through an area equal to the cross-section of the magnetosphere has been used. Here I identify another reference value of mass input, independent of the solar wind and constructed from planetary parameters alone, which can be shown to represent a mass input sufficiently large to prevent corotation already at the source location. The source rate from Enceladus at Saturn has been reported to be an order of magnitude smaller (in absolute numbers than that from Io at Jupiter. Both reference values, however, are also smaller at Saturn than at Jupiter, by factors ~40 to 60; expressed in dimensionless form, the estimated mass input from Enceladus may be larger than that from Io by factors ~4 to 6. The magnetosphere of Saturn may thus, despite a lower mass input in kg s−1, intrinsically be more heavily mass-loaded than the magnetosphere of Jupiter.

  1. Industrial application of electron sources with plasma emitters

    CERN Document Server

    Belyuk, S I; Rempe, N G

    2001-01-01

    Paper contains a description, operation, design and parameters of electron sources with plasma emitters. One presents examples of application of these sources as part of automated electron-beam welding lines. Paper describes application of such sources for electron-beam deposition of composite powders. Electron-beam deposition is used to rebuild worn out part and to increase strength of new parts of machines and tools. Paper presents some examples of rebuilding part and the advantages gained in this case

  2. Candidate plasma-facing materials for EUV lithography source components

    Science.gov (United States)

    Hassanein, Ahmed; Burtseva, Tatiana; Brooks, Jeff N.; Konkashbaev, Isak K.; Rice, Bryan J.

    2003-06-01

    Material selection and lifetime issues for extreme ultraviolet (EUV) lithography are of critical importance to the success of this technology for commercial applications. This paper reviews current trends in production and use of plasma-facing electrodes, insulators, and wall materials for EUV type sources. Ideal candidate materials should be able to: withstand high thermal shock from the short pulsed plasma; withstand high thermal loads without structural failure; reduce debris generation during discharge; and be machined accurately. We reviewed the literature on current and proposed fusion plasma-facing materials as well as current experience with plasma gun and other simulation devices. Both fusion and EUV source materials involve issues of surface erosion by particle sputtering and heat-induced evaporation/melting. These materials are either bare structural materials or surface coatings. EUV materials can be divided into four categories: wall, electrode, optical, and insulator materials. For electric discharge sources, all four types are required, whereas laser-produced plasma EUV sources do not require electrode and insulator materials. Several types of candidate alloy and other materials and methods of manufacture are recommended for each component of EUV lithography light sources.

  3. Surface-wave plasma source with magnetic multicusp fields; Multicusp jiba tojikome hyomenha plasma gen

    Energy Technology Data Exchange (ETDEWEB)

    Tsuda, M.; Ono, K.; Tsuchihashi, M.; Hanazaki, M.; Komemura, T. [Mitsubishi Electric Corp., Tokyo (Japan)

    1998-11-01

    A new-type microwave plasma source has been developed for materials processing. The plasma reactor employed a launcher of azimuthally symmetric surface waves at a frequency of 2.45 GHz and also magnetic multicusp fields around the reactor chamber walls. This configuration yielded high-density (Ne {>=} 10{sup 11}cm{sup -3}) plasmas sustained by surface waves even at low gas pressures below 10 m Torr, following easy plasma ignition by electron cyclotron resonance (ECR) discharges. Electrical and optical diagnostics were made to obtain the plasma properties in Ar. It was shown that a transition from ECR excited to surface-wave excited plasmas occurs under conditions where the plasma electron density exceeds a critical value of Ne-1 times 10{sup 11}cm{sup -3}. 21 refs., 14 figs.

  4. Mass identification of the neutral products generated in the plasma treatment of polluted atmospheres

    Science.gov (United States)

    Seymour, David

    2013-09-01

    Plasmas produced using Dielectric Barrier Discharge (DBD) devices are very effective in the abatement of air pollution resulting from, for example, the emission of volatile organic compounds (VCOs) by a range of industrial and agricultural processes. The development and monitoring of effective DBD systems can be investigated by advanced mass spectrometric methods specifically configured for analysis at high and atmospheric pressures The present work involves the operation of a small DBD reactor which uses either a helium or nitrogen carrier gas to sustain the plasma to which may be added reactive gases, such as oxygen, as well as samples of pollutants such as chlorinated hydrocarbons, including trichloroethylene. The mass spectrometric analysis was performed using a specially configured system manufactured by Hiden Analytical Ltd. The DBD source may also be combined with a catalyst for plasma-enhanced catalysis. The neutral products of the reactions proceeding in the plasma at atmospheric pressure are sampled through the capillary sampling system which also reduces the pressure of the gas mixture delivered to the ionisation source of the quadrupole mass spectrometer. The ions produced are subsequently mass identified. We describe typical data and comment on the advantages of this technique.

  5. A highly reliable trigger for vacuum ARC plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Bernardet, H.; Godechot, X.; Jarjat, F. [SODERN, Limeil-Brevannes (France)

    1996-08-01

    The authors have developed a reliable electrical trigger and its associated circuitry to fire vacuum arc plasma or ion source. They tested different embodiments of the trigger device in order to get a highly reliable one, which is able to perform more than 1.2 x 10{sup 6} shots at 60 A and 6.5 ps pulse length. The evolution of the ion current emitted has been recorded as a function of the number of shots. They have also investigated in which direction the plasma jet is emitted : axially or radially. This device can be used to fire a vacuum arc plasma or ion source by plasma injection. It has obvious advantage to be placed outside the cathode and therefore would ease maintenance of vacuum arc devices.

  6. Plasma Heating Suring a Coronal Mass Ejection Observed by SOHO

    CERN Document Server

    Murphy, N A; Korreck, K E

    2011-01-01

    We perform a time-dependent ionization analysis to constrain plasma heating requirements during a fast partial halo coronal mass ejection (CME) observed on 2000 June 28 by the Ultraviolet Coronagraph Spectrometer (UVCS) aboard the Solar and Heliospheric Observatory (SOHO). We use two methods to derive densities from the UVCS measurements, including a density sensitive O V line ratio at 1213.85 and 1218.35 Angstroms, and radiative pumping of the O VI 1032,1038 doublet by chromospheric emission lines. The most strongly constrained feature shows cumulative plasma heating comparable to or greater than the kinetic energy, while features observed earlier during the event show cumulative plasma heating comparable to or less than the kinetic energy. SOHO Michelson Doppler Imager (MDI) observations are used to estimate the active region magnetic energy. We consider candidate plasma heating mechanisms and provide constraints when possible. Because this CME was associated with a relatively weak flare, the contribution b...

  7. Are Spicules the Primary Source of Hot Coronal Plasma?

    Science.gov (United States)

    Klimchuk, James A.

    2011-01-01

    The recent discovery of Type II spicules has generated considerable excitement. It has even been suggested that these ejections can account for a majority of the hot plasma observed in the corona, thus obviating the need for "coronal" heating. If this is the case, however, then there should be observational consequences. We have begun to examine some of these consequences and find reason to question the idea that spicules are the primary source of hot coronal plasma.

  8. Photoionization of an aluminum plasma by a tantalum X source

    Science.gov (United States)

    Renaudin, Patrick; Back, Christina A.; Chenais-Popovics, Claude; Audebert, Patrick; Geindre, Jean-Paul; Gauthier, Jean-Claude

    1991-05-01

    Photoionization of a helium like aliminum plasma is carried out by an external x-source. The laser beam used corresponds to the 3d to 4F transition level of tantalum. The experimental spectrum of tantalum is shown superimposed over the emission spectrum of aluminum on diagrammatic form. Good correspondence is seen between the 3d to 4F emissions of tantalum and helium like aluminum. Plasma pumping is obtained by exposure of a tantalum target to laser rays.

  9. Simple filtered repetitively pulsed vacuum arc plasma source

    Science.gov (United States)

    Chekh, Yu.; Zhirkov, I. S.; Delplancke-Ogletree, M. P.

    2010-02-01

    A very simple design of cathodic filtered vacuum arc plasma source is proposed. The source without filter has only four components and none of them require precise machining. The source operates in a repetitively pulsed regime, and for laboratory experiments it can be used without water cooling. Despite the simple construction, the source provides high ion current at the filter outlet reaching 2.5% of 400 A arc current, revealing stable operation in a wide pressure range from high vacuum to oxygen pressure up to more than 10-2 mbar. There is no need in complicated power supply system for this plasma source, only one power supply can be used to ignite the arc, to provide the current for the arc itself, to generate the magnetic field in the filter, and provide its positive electric biasing without any additional high power resistance.

  10. e+e- Plasma Photon Source

    Energy Technology Data Exchange (ETDEWEB)

    Hartouni, Ed P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-12-06

    This note addresses the idea of a photon source that is based on an e+e- plasma created by co-propagating beams of e+ and e-. The plasma has a well-defined temperature, and the thermal distribution of the charged particles is used to average over the relative velocity cross section multiplied by the relative velocity. Two relevant cross sections are the direct “free-free” annihilation of e+e- pairs in the plasma, and the radiative recombination of e+e- pairs into positronium (Ps) which subsequently undergoes annihilation.

  11. Crux: rapid open source protein tandem mass spectrometry analysis.

    Science.gov (United States)

    McIlwain, Sean; Tamura, Kaipo; Kertesz-Farkas, Attila; Grant, Charles E; Diament, Benjamin; Frewen, Barbara; Howbert, J Jeffry; Hoopmann, Michael R; Käll, Lukas; Eng, Jimmy K; MacCoss, Michael J; Noble, William Stafford

    2014-10-03

    Efficiently and accurately analyzing big protein tandem mass spectrometry data sets requires robust software that incorporates state-of-the-art computational, machine learning, and statistical methods. The Crux mass spectrometry analysis software toolkit ( http://cruxtoolkit.sourceforge.net ) is an open source project that aims to provide users with a cross-platform suite of analysis tools for interpreting protein mass spectrometry data.

  12. Generation of metal ions in the beam plasma produced by a forevacuum-pressure electron beam source

    Energy Technology Data Exchange (ETDEWEB)

    Tyunkov, A. V.; Yushkov, Yu. G., E-mail: YuYushkov@sibmail.com; Zolotukhin, D. B.; Klimov, A. S. [Tomsk State University of Control Systems and Radioelectronics, Tomsk 634050 (Russian Federation); Savkin, K. P. [High Current Electronics Institute, Russian Academy of Sciences, Tomsk 634055 (Russian Federation)

    2014-12-15

    We report on the production of metal ions of magnesium and zinc in the beam plasma formed by a forevacuum-pressure electron source. Magnesium and zinc vapor were generated by electron beam evaporation from a crucible and subsequently ionized by electron impact from the e-beam itself. Both gaseous and metallic plasmas were separately produced and characterized using a modified RGA-100 quadrupole mass-spectrometer. The fractional composition of metal isotopes in the plasma corresponds to their fractional natural abundance.

  13. 21 CFR 640.64 - Collection of blood for Source Plasma.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Collection of blood for Source Plasma. 640.64... (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.64 Collection of blood for Source Plasma. (a) Supervision. All blood for the collection of Source Plasma shall...

  14. Counter-facing plasma guns for efficient extreme ultra-violet plasma light source

    Directory of Open Access Journals (Sweden)

    Kuroda Yusuke

    2013-11-01

    Full Text Available A plasma focus system composed of a pair of counter-facing coaxial guns was proposed as a long-pulse and/or repetitive high energy density plasma source. We applied Li as the source of plasma for improvement of the conversion efficiency, the spectral purity, and the repetition capability. For operation of the system with ideal counter-facing plasma focus mode, we changed the system from simple coaxial geometry to a multi-channel configuration. We applied a laser trigger to make synchronous multi-channel discharges with low jitter. The results indicated that the configuration is promising to make a high energy density plasma with high spectral efficiency.

  15. E × B ion mass spectroscopy in magnetised plasmas

    Science.gov (United States)

    Hellblom, K. G.; Armstrong, R. J.

    1995-02-01

    A spectrometer based on the E × B drift during the transit time of the ion through a cross field region has been tested in a hydrogen plasma in the Blaamann toroidal plasma device [T. Brundtland, Vacuum 43 (1992) 185]. The magnetic field B, is the field of the device. The electric field E, which is imposed and oriented perpendicular to the magnetic field, is swept with a time long compared to the ion transit time. The ions are accelerated along the magnetic field as they enters the cross field region giving them a velocity and a transit time proportional to the charge over the mass.

  16. Comparison of Plasma Activation of Thin Water Layers by Direct and Remote Plasma Sources

    Science.gov (United States)

    Kushner, Mark

    2014-10-01

    Plasma activation of liquids is now being investigated for a variety of biomedical applications. The plasma sources used for this activation can be generally classified as direct (the plasma is in contact with the surface of the liquid) or remote (the plasma does not directly touch the liquid). The direct plasma source may be a dielectric barrier discharge (DBD) where the surface of the liquid is a floating electrode or a plasma jet in which the ionization wave forming the plasma plume reaches the liquid. The remote plasma source may be a DBD with electrodes electrically isolated from the liquid or a plasma jet in which the ionization wave in the plume does not reach the liquid. In this paper, a comparison of activation of thin water layers on top of tissue, as might be encountered in wound healing, will be discussed using results from numerical investigations. We used the modeling platform nonPDPSIM to simulate direct plasma activation of thin water layers using DBDs and remote activation using plasma jets using up to hundreds of pulses. The DBDs are sustained in humid air while the plasma jets consist of He/O2 mixtures flowed into humid air. For similar number of pulses and energy deposition, the direct DBD plasma sources produce more acidification and higher production of nitrates/nitrites in the liquid. This is due to the accumulation of NxOy plasma jets, the convective flow removes many of these species prior to their diffusing into the water or reacting to form higher nitrogen oxides. This latter effect is sensitive to the repetition rate which determines whether reactive species formed during prior pulses overlap with newly produced reactive species. in the gas phase. In the plasma jets, the convective flow removes many of these species prior to their diffusing into the water or reacting to form higher nitrogen oxides. This latter effect is sensitive to the repetition rate which determines whether reactive species formed during prior pulses overlap with

  17. Neutron Source from Laser Plasma Acceleration

    Science.gov (United States)

    Jiao, Xuejing; Shaw, Joseph; McCary, Eddie; Downer, Mike; Hegelich, Bjorn

    2016-10-01

    Laser driven electron beams and ion beams were utilized to produce neutron sources via different mechanism. On the Texas Petawatt laser, deuterized plastic, gold and DLC foil targets of varying thickness were shot with 150 J , 150 fs laser pulses at a peak intensity of 2 ×1021W /cm2 . Ions were accelerated by either target normal sheath acceleration or Breakout Afterburner acceleration. Neutrons were produced via the 9Be(d,n) and 9Be(p,n) reactions when accelerated ions impinged on a Beryllium converter as well as by deuteron breakup reactions. We observed 2 ×1010 neutron per shot in average, corresponding to 5 ×1018n /s . The efficiencies for different targets are comparable. In another experiment, 38fs , 0.3 J UT3 laser pulse interacted with mixed gas target. Electrons with energy 40MeV were produced via laser wakefield acceleration. Neutron flux of 2 ×106 per shot was generated through bremsstrahlung and subsequent photoneutron reactions on a Copper converter.

  18. Assistant Anode in a Cathodic Arc Plasma Source

    Institute of Scientific and Technical Information of China (English)

    张涛; Paul K. Chu; 张荟星; Ian G. Brown

    2001-01-01

    The performance and characteristics of a cathodic arc plasma source, consisting of a titanium cathode, an anode with and without a tungsten mesh, and a coil producing a focusing magnetic field between the anode and cathode,are investigated. The high transparency and large area of the mesh allow a high plasma flux to penetrate the anode from the cathodic arc. The mesh helps to decrease the arc resistance and the ignition voltage of the cathodic arc in the focusing magnetic field, and to increase the life of the source, which means that the source makes the cathodic arc easily and greatly stabilized during the operation when a focusing magnetic field exists in the source.

  19. Dense plasma focus (DPF) accelerated non radio isotopic radiological source

    Energy Technology Data Exchange (ETDEWEB)

    Rusnak, Brian; Tang, Vincent

    2017-01-31

    A non-radio-isotopic radiological source using a dense plasma focus (DPF) to produce an intense z-pinch plasma from a gas, such as helium, and which accelerates charged particles, such as generated from the gas or injected from an external source, into a target positioned along an acceleration axis and of a type known to emit ionizing radiation when impinged by the type of accelerated charged particles. In a preferred embodiment, helium gas is used to produce a DPF-accelerated He2+ ion beam to a beryllium target, to produce neutron emission having a similar energy spectrum as a radio-isotopic AmBe neutron source. Furthermore, multiple DPFs may be stacked to provide staged acceleration of charged particles for enhancing energy, tunability, and control of the source.

  20. Plasmas in compact traps: From ion sources to multidisciplinary research

    Science.gov (United States)

    Mascali, D.; Musumarra, A.; Leone, F.; Galatà, A.; Romano, F. P.; Gammino, S.

    2017-09-01

    In linear (minimum-B) magneto-static traps dense and hot plasmas are heated by electromagnetic radiation in the GHz domain via the Electron Cyclotron Resonance (ECR). The values of plasma density, temperature and confinement times ( n_eτ_i>10^{13} cm ^{-3} s; T_e>10 keV) are similar to the ones of thermonuclear plasmas. The research in this field -devoted to heating and confinement optimization- has been supported by numerical modeling and advanced diagnostics, for probing the plasma especially in a non-invasive way. ECR-based systems are nowadays able to produce extremely intense (tens or hundreds of mA) beams of light ions (p, d, He), and relevant currents of heavier elements (C, O, N) up to heavy ions like Xe, Pb, U. Such beams can be extracted from the trap by a proper electrostatic system. The above-mentioned properties make these plasmas very attractive for interdisciplinary researches also, such as i) nuclear decays rates measurements in stellar-like conditions, ii) energy conversion studies, being exceptional sources of short-wavelength electromagnetic radiation (EUV, X-rays, hard X-rays and gammas, useful in material science and archaeometry), iii) environments allowing precise spectroscopical measurements as benchmarks for magnetized astrophysical plasmas. The talk will give an overview about the state-of-the-art in the field of intense ion sources, and some new perspectives for interdisciplinary research, with a special attention to the developments based at INFN-LNS.

  1. Mirror-field confined compact plasma source using permanent magnet for plasma processings

    Science.gov (United States)

    Goto, Tetsuya; Sato, Kei-ichiro; Yabuta, Yuki; Sugawa, Shigetoshi

    2016-12-01

    A mirror-field confined compact electron cyclotron resonance (ECR) plasma source using permanent magnets was developed, aiming for the realization of high-quality plasma processings where high-density reactive species are supplied to a substrate with minimizing the ion bombardment damages. The ECR position was located between a microwave transmissive window and a quartz limiter, and plasmas were transported from the ECR position to a midplane of the magnetic mirror field through the quartz limiter. Thus, a radius of core plasma could be determined by the limiter, which was 15 mm in this study. Plasma parameters were investigated by the Langmuir probe measurement. High-density plasma larger than 1011 cm-3 could be produced by applying 5.85-GHz microwave power of 10 W or more. For the outside region of the core plasma where a wafer for plasma processings will be set at, the ion current density was decreased dramatically with distance from the core plasma and became smaller by approximately two orders of magnitude that in the core plasma region for the radial position of 40 mm, suggesting the realization of reduction in ion bombardment damages.

  2. Mirror-field confined compact plasma source using permanent magnet for plasma processings.

    Science.gov (United States)

    Goto, Tetsuya; Sato, Kei-Ichiro; Yabuta, Yuki; Sugawa, Shigetoshi

    2016-12-01

    A mirror-field confined compact electron cyclotron resonance (ECR) plasma source using permanent magnets was developed, aiming for the realization of high-quality plasma processings where high-density reactive species are supplied to a substrate with minimizing the ion bombardment damages. The ECR position was located between a microwave transmissive window and a quartz limiter, and plasmas were transported from the ECR position to a midplane of the magnetic mirror field through the quartz limiter. Thus, a radius of core plasma could be determined by the limiter, which was 15 mm in this study. Plasma parameters were investigated by the Langmuir probe measurement. High-density plasma larger than 10(11) cm(-3) could be produced by applying 5.85-GHz microwave power of 10 W or more. For the outside region of the core plasma where a wafer for plasma processings will be set at, the ion current density was decreased dramatically with distance from the core plasma and became smaller by approximately two orders of magnitude that in the core plasma region for the radial position of 40 mm, suggesting the realization of reduction in ion bombardment damages.

  3. A low-energy linear oxygen plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Anders, Andre; Yushkov, Georgy Yu.

    2007-01-08

    A new version of a Constricted Plasma Source is described,characterized by all metal-ceramic construction, a linear slit exit of180 mm length, and cw-operation (typically 50 kHz) at an average power of1.5 kW. The plasma source is here operated with oxygen gas, producingstreaming plasma that contains mainly positive molecular and atomic ions,and to a much lesser degree, negative ions. The maximum total ion currentobtained was about 0.5 A. The fraction of atomic ions reached more than10 percent of all ions when the flow rate was less then 10 sccm O2,corresponding to a chamber pressure of about 0.5 Pa for the selectedpumping speed. The energy distribution functions of the different ionspecies were measured with a combinedmass spectrometer and energyanalyzer. The time-averaged distribution functions were broad and rangedfrom about 30eV to 90 eV at 200 kHz and higher frequencies, while theywere only several eV broad at 50 kHz and lower frequencies, with themaximum located at about 40 eV for the grounded anode case. This maximumwas shifted down to about 7 eV when the anode was floating, indicatingthe important role of the plasma potential for the ion energy for a givensubstrate potential. The source could be scaled to greater length and maybe useful for functionalization of surfaces and plasma-assisteddeposition of compound films.

  4. VUV SOURCE FROM PULSED-LASER GENERATED PLASMA

    OpenAIRE

    Laporte, P.; Damany, N.; Damany, H.

    1987-01-01

    We describe a pulsed vacuum ultraviolet (VUV) source consisting of a plasma created by focusing a NdYAG laser beam into rare gases under moderate pressure, and we report on spectral and time properties of that source. Main features are : continuum emission in a large spectral range, with only few lines superimposed, good time characteristics of the pulses, stability, cleanliness, and relatively high repetition rate (20 Hz).

  5. Modeling of plasma transport and negative ion extraction in a magnetized radio-frequency plasma source

    Science.gov (United States)

    Fubiani, G.; Garrigues, L.; Hagelaar, G.; Kohen, N.; Boeuf, J. P.

    2017-01-01

    Negative ion sources for fusion are high densities plasma sources in large discharge volumes. There are many challenges in the modeling of these sources, due to numerical constraints associated with the high plasma density, to the coupling between plasma and neutral transport and chemistry, the presence of a magnetic filter, and the extraction of negative ions. In this paper we present recent results concerning these different aspects. Emphasis is put on the modeling approach and on the methods and approximations. The models are not fully predictive and not complete as would be engineering codes but they are used to identify the basic principles and to better understand the physics of the negative ion sources.

  6. Effect of Substrate Potential on Plasma Parameters of Magnetic Multicusp Plasma Source

    Science.gov (United States)

    Ueda, Yoshio; Goto, Masahiro

    1998-06-01

    The effect of substrate potential on plasmas produced in a magnetic multicusp plasma source has been studied experimentally. Plasma parameters such as electron temperature and plasma potential are estimated from electron energy distribution function numerically calculated from probe current-voltage characteristics. For a substrate potential of -150 V with respect to the source chamber, which is much lower than substrate floating potentials, the plasma parameters are not affected by the application of the potential. However, for the case where the substrate is shorted with the source chamber, the high energy component of electrons significantly decreases in comparison with the floating case leading to the reduction of electron temperature. In this case, plasma potential is positive with respect to the substrate to suppress electron loss but its absolute value is only of the order of electron temperature in eV, which is much lower than the potential between the plasma and the substrate in the floating case. This discharge mode could be advantageous in significantly reducing the ion impact energy to the substrate plate.

  7. Three Filtered Vacuum Arc Plasma Sources Deposition & Implantation System

    Institute of Scientific and Technical Information of China (English)

    WU Xian-ying; ZHANG Hui-xing; LI Qiang

    2004-01-01

    A deposition & implantation system, which includes three filtered vacuum arc plasma sources, has been built. Vacuum arc discharge is used to produce high-density metal plasma; Curved magnetic filtering technique is used to transfer the plasma into out-of-sight vacuum chamber and reduce macro-particles from the vacuum arc plasma in order to drastically reduce the macro-particles contamination of the films. The up to 30 kV negative bias applied to the target can be used for ion implantation in order to improve the film adhesion; or for ion sputtering to clear the substrate surface. The 0 to 300 V negative bias can be used to adjust the ion energy which forming films. The system is designed for various thin films synthesizing, such as single-layer, compound layer, multi-layer films. It's principle, components and applications are described in the literature.

  8. RF Plasma modeling of the Linac4 H− ion source

    CERN Document Server

    Mattei, S; Hatayama, A; Lettry, J; Kawamura, Y; Yasumoto, M; Schmitzer, C

    2013-01-01

    This study focuses on the modelling of the ICP RF-plasma in the Linac4 H− ion source currently being constructed at CERN. A self-consistent model of the plasma dynamics with the RF electromagnetic field has been developed by a PIC-MCC method. In this paper, the model is applied to the analysis of a low density plasma discharge initiation, with particular interest on the effect of the external magnetic field on the plasma properties, such as wall loss, electron density and electron energy. The use of a multi-cusp magnetic field effectively limits the wall losses, particularly in the radial direction. Preliminary results however indicate that a reduced heating efficiency results in such a configuration. The effect is possibly due to trapping of electrons in the multi-cusp magnetic field, preventing their continuous acceleration in the azimuthal direction.

  9. Study on Performance Parameters of the Plasma Source for a Short-Conduction-Time Plasma Opening Switch

    Institute of Scientific and Technical Information of China (English)

    LUO Weixi; ZENG Zhengzhong; WANG Liangping; LEI Tianshi; HU Yixiang; HUANG Tao; SUN Tieping

    2012-01-01

    Plasma source performance parameters, including plasma ejection density and velocity, greatly affect the operation of a short-conduction-time plasma opening switch (POS). In this paper, the plasma source used in the POS of Qiangguang I generator is chosen as the study object. At first the POS working process is analyzed. The result shows that the opening performance of the POS can be improved by increasing the plasma ejection velocity and decreasing the plasma density. The influence of the cable plasma gun structure and number on the plasma ejection parameters is experimentally investigated with two charge collectors. Finally a semi-empirical model is proposed to describe the experimental phenomenon.

  10. Modeling of negative ion transport in a plasma source

    Science.gov (United States)

    Riz, David; Paméla, Jérôme

    1998-08-01

    A code called NIETZSCHE has been developed to simulate the negative ion transport in a plasma source, from their birth place to the extraction holes. The ion trajectory is calculated by numerically solving the 3-D motion equation, while the atomic processes of destruction, of elastic collision H-/H+ and of charge exchange H-/H0 are handled at each time step by a Monte-Carlo procedure. This code can be used to calculate the extraction probability of a negative ion produced at any location inside the source. Calculations performed with NIETZSCHE have allowed to explain, either quantitatively or qualitatively, several phenomena observed in negative ion sources, such as the isotopic H-/D- effect, and the influence of the plasma grid bias or of the magnetic filter on the negative ion extraction. The code has also shown that in the type of sources contemplated for ITER, which operate at large arc power densities (>1 W cm-3), negative ions can reach the extraction region provided if they are produced at a distance lower than 2 cm from the plasma grid in the case of «volume production» (dissociative attachment processes), or if they are produced at the plasma grid surface, in the vicinity of the extraction holes.

  11. Modeling of negative ion transport in a plasma source (invited)

    Science.gov (United States)

    Riz, David; Paméla, Jérôme

    1998-02-01

    A code called NIETZSCHE has been developed to simulate the negative ion transport in a plasma source, from their birth place to the extraction holes. The H-/D- trajectory is calculated by numerically solving the 3D motion equation, while the atomic processes of destruction, of elastic collision with H+/D+ and of charge exchange with H0/D0 are handled at each time step by a Monte Carlo procedure. This code can be used to calculate the extraction probability of a negative ion produced at any location inside the source. Calculations performed with NIETZSCHE have been allowed to explain, either quantitatively or qualitatively, several phenomena observed in negative ion sources, such as the isotopic H-/D- effect, and the influence of the plasma grid bias or of the magnetic filter on the negative ion extraction. The code has also shown that, in the type of sources contemplated for ITER, which operate at large arc power densities (>1 W cm-3), negative ions can reach the extraction region provided they are produced at a distance lower than 2 cm from the plasma grid in the case of volume production (dissociative attachment processes), or if they are produced at the plasma grid surface, in the vicinity of the extraction holes.

  12. Large-Area Permanent-Magnet ECR Plasma Source

    Science.gov (United States)

    Foster, John E.

    2007-01-01

    A 40-cm-diameter plasma device has been developed as a source of ions for material-processing and ion-thruster applications. Like the device described in the immediately preceding article, this device utilizes electron cyclotron resonance (ECR) excited by microwave power in a magnetic field to generate a plasma in an electrodeless (noncontact) manner and without need for an electrically insulating, microwave-transmissive window at the source. Hence, this device offers the same advantages of electrodeless, windowless design - low contamination and long operational life. The device generates a uniform, high-density plasma capable of sustaining uniform ion-current densities at its exit plane while operating at low pressure [magnetic field in this device is generated by a permanent-magnet circuit that is optimized to generate resonance surfaces. The microwave power is injected on the centerline of the device. The resulting discharge plasma jumps into a "high mode" when the input power rises above 150 W. This mode is associated with elevated plasma density and high uniformity. The large area and uniformity of the plasma and the low operating pressure are well suited for such material-processing applications as etching and deposition on large silicon wafers. The high exit-plane ion-current density makes it possible to attain a high rate of etching or deposition. The plasma potential is <3 V low enough that there is little likelihood of sputtering, which, in plasma processing, is undesired because it is associated with erosion and contamination. The electron temperature is low and does not vary appreciably with power.

  13. SVSCf plasma desorption mass spectrometry: recent advances and applications

    Energy Technology Data Exchange (ETDEWEB)

    Kamensky, I.; Craig, A.G.

    1987-01-01

    SVSCf plasma desorption mass spectrometry (PDMS) as utilized in the BIO-ION instruments is described. The sensitivity of the technique is investigated for varying amounts of bovine insulin. The results show accurate mass assignment for pmole amounts of sample. Several methods, currently used for sample preparation in PDMS, are described. Spectra of the antibiotic nisin using two different sample preparation techniques show significant variation. The fragmentation pattern of reduced acetylated maltoheptaose is also presented. The initial results obtained using a new PDMS instrument equipped with variable flight path are shown. The increased resolution is illustrated using the extended flight path to measure the molecular ion region of the maltoheptaose.

  14. Measurement of the effective plasma ion mass in large tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Lister, J.B.; Villard, L.; Ridder, G. de [Ecole Polytechnique Federale, Lausanne (Switzerland). Centre de Recherche en Physique des Plasma (CRPP)

    1997-06-01

    There is not yet a straightforward method for the measurement of the D-T ratio in the centre of a tokamak plasma. One of the simpler measurements put forward in the past is the interpretation of the MHD spectrum in the frequency range of the Global Alfven Eigenmodes (GAE). However, the frequencies of these modes do not only depend on the plasma mass, but are also quite strongly dependent on the details of the current and density profiles, creating a problem of deconvolution of the estimate of the plasma mass from an implicit relationship between several measurable plasma parameters and the detected eigenmode frequencies. This method has been revised to assess its likely precision for the JET tokamak. The low n GAE modes are sometimes too close to the continuum edge to be detectable and the interpretation of the GAE spectrum is rendered less direct than had been hoped. We present a statistical study on the precision with which the D-T ratio could be estimated from the GAE spectrum on JET. (author) 4 figs., 8 refs.

  15. A Simulator for Producing of High Flux Atomic Oxygen Beam by Using ECR Plasma Source

    Institute of Scientific and Technical Information of China (English)

    Shuwang DUO; Meishuan LI; Yaming ZHANG

    2004-01-01

    In order to study the atomic oxygen corrosion of spacecraft materials in low earth orbit environment, an atomic oxygen simulator was established. In the simulator, a 2.45 GHz microwave source with maximum power of 600 W was launched into the circular cavity to generate ECR (electron cyclotron resonance) plasma. The oxygen ion beam moved onto a negatively biased Mo plate under the condition of symmetry magnetic mirror field confine, then was neutralized and reflected to form oxygen atom beam. The properties of plasma density, electron temperature, plasma space potential and ion incident energy were characterized. The atomic oxygen beam flux was calibrated by measuring the mass loss rate of Kapton during the atomic 5~30 eV and a cross section of φ80 mm could be obtained under the operating pressure of 10-1~10-3 Pa. Such a high flux source can provide accelerated simulation tests of materials and coatings for space applications.

  16. Intense ion beam generation, plasma radiation source and plasma opening switch research

    Science.gov (United States)

    Hammer, D. A.; Coleman, M. D.; Qi, N.; Similon, P. L.; Sudan, R. N.

    1989-04-01

    This report describes research on intense ion beam diodes, plasma opening switches and dense z-pinch plasma radiators. Laser induced fluorescence spectroscopy has been used to map the electrostatic potential profile in a plasma-prefilled magnetically insulated ion diode. In a simple planar diode, the measured profile is inconsistent with the electrons being confined in a sheath near the cathode by the magnetic field. Rather, the profile implies the presence of electrons throughout the accelerating gap. A theoretical model of the penetration of current and magnetic field into a plasma, and of the current-driven effective collision frequency has been developed. The snowplow action of the rising magnetic field causes a steep rise in the plasma density at the leading edge. The subsequent multistreaming of the ions caused by ion reflection at the current layer could lead to ion heating through collective effects. The two-dimensional electron flow in the plasma cathode vacuum gap is also treated. Dense z-pinch plasma radiation source experiments have been initiated on the LION accelerator using gas puff and fine wire loads. The x-pinch was found to be a more effective way to generate soft x-rays than a single wire pinch or a gas puff implosion. Plasma opening switch experiments being initiated, and plasma anode ion diode development work being terminated are also briefly described.

  17. Plasma and Ion Sources in Large Area Coatings: A Review

    Energy Technology Data Exchange (ETDEWEB)

    Anders, Andre

    2005-02-28

    Efficient deposition of high-quality coatings often requires controlled application of excited or ionized particles. These particles are either condensing (film-forming) or assisting by providing energy and momentum to the film growth process, resulting in densification, sputtering/etching, modification of stress, roughness, texture, etc. In this review, the technical means are surveyed enabling large area application of ions and plasmas, with ion energies ranging from a few eV to a few keV. Both semiconductortype large area (single wafer or batch processing with {approx} 1000 cm{sup 2}) and in-line web and glass-coating-type large area (> 10{sup 7} m{sup 2} annually) are considered. Characteristics and differences between plasma and ion sources are explained. The latter include gridded and gridless sources. Many examples are given, including sources based on DC, RF, and microwave discharges, some with special geometries like hollow cathodes and E x B configurations.

  18. Overdense plasma generation in a compact ion source

    Science.gov (United States)

    Castro, G.; Mascali, D.; Gammino, S.; Torrisi, G.; Romano, F. P.; Celona, L.; Altana, C.; Caliri, C.; Gambino, N.; Lanaia, D.; Miracoli, R.; Neri, L.; Sorbello, G.

    2017-05-01

    Electron cyclotron resonance ion sources (ECRIS) are widely used plasma based machines for the production of intense ion beams in science and industry. The performance of modern devices is limited by the presence of the density cut-off, above which electromagnetic (EM) waves sustaining the plasma are reflected. We hereby discuss the systematic data analysis of electrostatic wave generation in an ECR prototype operating at 3.75 GHz-0.1 THz. In particular, electron Bernstein waves (EBW) have been excited. EBW have already been generated in large-scale plasma devices for thermonuclear fusion purposes. In ion sources where L c ˜ λ RF (L c being the plasma chamber size and λ RF the pumping wave wavelength) the EM field assumes a modal behaviour; thus both plasma and EM field self-organize so that no optical-like wave launching is possible (i.e. the cavity effect dominates on the optical path). The collected data, however, supported by 3D full-wave simulations, actually demonstrate that a Budden-type X-B conversion scenario can be established above some critical RF power thresholds, operating in an off-ECR regime. The generation and absorption of the EBW has been demonstrated by the presence of three peculiar signatures: along with the establishment of an overdense plasma, generation of supra-thermal electrons and modification (non-linear broadening) of the EM spectrum measured within the plasma have been observed. At the threshold establishing such a heating regime, the collected data provide evidence for a fast rotation of the electron fluid.

  19. Oscillating plasma bubbles. III. Internal electron sources and sinks

    Energy Technology Data Exchange (ETDEWEB)

    Stenzel, R. L.; Urrutia, J. M. [Department of Physics and Astronomy, University of California, Los Angeles, California 90095-1547 (United States)

    2012-08-15

    An internal electron source has been used to neutralize ions injected from an ambient plasma into a spherical grid. The resultant plasma is termed a plasma 'bubble.' When the electron supply from the filament is reduced, the sheath inside the bubble becomes unstable. The plasma potential of the bubble oscillates near but below the ion plasma frequency. Different modes of oscillations have been observed as well as a subharmonic and multiple harmonics. The frequency increases with ion density and decreases with electron density. The peak amplitude occurs for an optimum current and the instability is quenched at large electron densities. The frequency also increases if Langmuir probes inside the bubble draw electrons. Allowing electrons from the ambient plasma to enter, the bubble changes the frequency dependence on grid voltage. It is concluded that the net space charge density in the sheath determines the oscillation frequency. It is suggested that the sheath instability is caused by ion inertia in an oscillating sheath electric field which is created by ion bunching.

  20. Modeling the chemistry of plasma polymerization using mass spectrometry.

    Science.gov (United States)

    Ihrig, D F; Stockhaus, J; Scheide, F; Winkelhake, Oliver; Streuber, Oliver

    2003-04-01

    The goal of the project is a solvent free painting shop. The environmental technologies laboratory is developing processes of plasma etching and polymerization. Polymerized thin films are first-order corrosion protection and primer for painting. Using pure acetylene we get very nice thin films which were not bonded very well. By using air as bulk gas it is possible to polymerize, in an acetylene plasma, well bonded thin films which are stable first-order corrosion protections and good primers. UV/Vis spectroscopy shows nitrogen oxide radicals in the emission spectra of pure nitrogen and air. But nitrogen oxide is fully suppressed in the presence of acetylene. IR spectroscopy shows only C=O, CH(2) and CH(3) groups but no nitrogen species. With the aid of UV/Vis spectra and the chemistry of ozone formation it is possible to define reactive traps and steps, molecule depletion and processes of proton scavenging and proton loss. Using a numerical model it is possible to evaluate these processes and to calculate theoretical mass spectra. Adjustment of theoretical mass spectra to real measurements leads to specific channels of polymerization which are driven by radicals especially the acetyl radical. The estimated theoretical mass spectra show the specific channels of these chemical processes. It is possible to quantify these channels. This quantification represents the mass flow through this chemical system. With respect to these chemical processes it is possible to have an idea of pollutant production processes.

  1. The ITER full size plasma source device design

    Energy Technology Data Exchange (ETDEWEB)

    Sonato, P. [Consorzio RFX, EURATOM-ENEA Association, Corso Stati Uniti 4, I-35127 Padova (Italy)], E-mail: piergiorgio.sonato@igi.cnr.it; Agostinetti, P.; Anaclerio, G.; Antoni, V.; Barana, O.; Bigi, M.; Boldrin, M. [Consorzio RFX, EURATOM-ENEA Association, Corso Stati Uniti 4, I-35127 Padova (Italy); Cavenago, M. [INFN, Legnaro, Padova (Italy); Dal Bello, S.; Palma, M. Dalla [Consorzio RFX, EURATOM-ENEA Association, Corso Stati Uniti 4, I-35127 Padova (Italy); Daniele, A. [ENEA, Frascati, Roma (Italy); D' Arienzo, M.; De Lorenzi, A.; Ferro, A.; Fiorentin, A.; Gaio, E.; Gazza, E.; Grando, L.; Fantini, F.; Fellin, F. [Consorzio RFX, EURATOM-ENEA Association, Corso Stati Uniti 4, I-35127 Padova (Italy)] (and others)

    2009-06-15

    In the framework of the strategy for the development and the procurement of the NB systems for ITER, it has been decided to build in Padova a test facility, including two experimental devices: a full size plasma source with low voltage extraction and a full size NB injector at full beam power (1 MV). These two different devices will separately address the main scientific and technological issues of the 17 MW NB injector for ITER. In particular the full size plasma source of negative ions will address the ITER performance requirements in terms of current density and uniformity, limitation of the electron/ion ratio and stationary operation at full current with high reliability and constant performances for the whole operating time up to 1 h. The required negative ion current density to be extracted from the plasma source ranges from 290 A/m{sup 2} in D{sub 2} (D{sup -}) and 350 A/m{sup 2} in H{sub 2} (H{sup -}) and these values should be obtained at the lowest admissible neutral pressure in the plasma source volume, nominally at 0.3 Pa. The electron to ion ratio should be limited to less than 1 and the admissible ion inhomogeneity extracted from the grids should be better than 10% on the whole plasma cross-section having a surface exposed to the extraction grid of the order of 1 m{sup 2}. The main design choices will be presented in the paper as well as an overview of the design of the main components and systems.

  2. Plasma shape control by pulsed solenoid on laser ion source

    Science.gov (United States)

    Sekine, M.; Ikeda, S.; Romanelli, M.; Kumaki, M.; Fuwa, Y.; Kanesue, T.; Hayashizaki, N.; Lambiase, R.; Okamura, M.

    2015-09-01

    A Laser ion source (LIS) provides high current heavy ion beams with a very simple mechanical structure. Plasma is produced by a pulsed laser ablation of a solid state target and ions are extracted by an electric field. However, it was difficult to manipulate the beam parameters of a LIS, since the plasma condition could only be adjusted by the laser irradiation condition. To enhance flexibility of LIS operation, we employed a pulsed solenoid in the plasma drift section and investigated the effect of the solenoid field on singly charged iron beams. The experimentally obtained current profile was satisfactorily controlled by the pulsed magnetic field. This approach may also be useful to reduce beam emittance of a LIS.

  3. Plasma shape control by pulsed solenoid on laser ion source

    Energy Technology Data Exchange (ETDEWEB)

    Sekine, M. [Tokyo Institute of Technology, Meguro-ku, Tokyo 2-12-1 (Japan); RIKEN, Wako, Saitama 351-0198 (Japan); Ikeda, S. [Tokyo Institute of Technology, Yokohama, Kanagawa 226-8502 (Japan); RIKEN, Wako, Saitama 351-0198 (Japan); Romanelli, M. [Cornell University, Ithaca, NY 14850 (United States); Kumaki, M. [RIKEN, Wako, Saitama 351-0198 (Japan); Waseda University, Shinjuku, Tokyo 169-0072 (Japan); Fuwa, Y. [RIKEN, Wako, Saitama 351-0198 (Japan); Kyoto University, Uji, Kyoto 611-0011 (Japan); Kanesue, T. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Hayashizaki, N. [Tokyo Institute of Technology, Meguro-ku, Tokyo 2-12-1 (Japan); Lambiase, R. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Okamura, M. [RIKEN, Wako, Saitama 351-0198 (Japan); Brookhaven National Laboratory, Upton, NY 11973 (United States)

    2015-09-21

    A Laser ion source (LIS) provides high current heavy ion beams with a very simple mechanical structure. Plasma is produced by a pulsed laser ablation of a solid state target and ions are extracted by an electric field. However, it was difficult to manipulate the beam parameters of a LIS, since the plasma condition could only be adjusted by the laser irradiation condition. To enhance flexibility of LIS operation, we employed a pulsed solenoid in the plasma drift section and investigated the effect of the solenoid field on singly charged iron beams. The experimentally obtained current profile was satisfactorily controlled by the pulsed magnetic field. This approach may also be useful to reduce beam emittance of a LIS.

  4. MEMS ion source for mass spectrometer integrated on a chip

    Science.gov (United States)

    Szyszka, P.; Grzebyk, T.; Górecka-Drzazga, A.; Dziuban, J. A.

    2016-11-01

    The paper describes silicon-glass MEMS electron impact ion source developed for miniature mass spectrometer (MS) integrated on a chip. The device consists of the field emission electron source with an electrophoretically deposited carbon nanotube cathode and ion beam formation electrodes. Ion source structure has been fabricated using MEMS technology. A complete manufacturing process of the test structures has been successfully elaborated and implemented.

  5. Hydrogen Plasma Generation with 200 MHz RF Ion Source

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeongtae; Park, Kwangmook; Seo, Dong Hyuk; Kim, Han-Sung; Kwon, Hyeok-Jung; Cho, Yong-Sub [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    The ion source for the system is required to be rugged with 2000 hours maintenance free operation time because it is installed in the vessel filled with SF6 gas at the pressure of 10 bar. A 200 MHz RF ion source is considered as an ion source. It is a simple construction and provides long life operation. The specifications of the ion source are 5 kV extraction voltage and 1 mA beam current referenced to the proton. RF ion source has been developed and undergone a performance test. Results of the test are presented. 200 MHz RF ion source is designated and manufactured. First of all test stand test of ion source are set up for a performance test of ion source. It includes a RF ion source, a 200-MHz RF system, beam extraction system, vacuum system, beam extraction system, and beam diagnostic system. At pressure of 1.2E-5 torr, hydrogen plasma is generated with net RF power 70 W. Pyrex tube surrounded by an inductive coil takes the role of vessel and discharge is enhanced with field of permanent magnets.

  6. A novel plasma source for sterilization of living tissues

    Energy Technology Data Exchange (ETDEWEB)

    Martines, E; Zuin, M; Cavazzana, R; Gazza, E; Serianni, G; Spagnolo, S; Spolaore, M [Consorzio RFX, Associazione Euratom-ENEA sulla Fusione, Padova (Italy); Leonardi, A; Deligianni, V [Department of Neuroscience, Ophthalmology Unit, University of Padova (Italy); Brun, P; Aragona, M [Department of Histology, Microbiology and Medical Biotechnology, Histology Unit, University of Padova (Italy); Castagliuolo, I; Brun, P [Department of Histology, Microbiology and Medical Biotechnology, Microbiology Unit, University of Padova (Italy)], E-mail: emilio.martines@igi.cnr.it

    2009-11-15

    A source for the production of low-power plasmas at atmospheric pressure, to be used for the nondamaging sterilization of living tissues, is presented. The source, powered by radiofrequency and working with a helium flow, has a specific configuration, studied to prevent the formation of electric arcs dangerous to living matter. It is capable of killing different types of bacteria with a decimal reduction time of 1-2 min; on the contrary, human cells such as conjunctival fibroblasts were found to be almost unharmed by the plasma. A high concentration of OH radicals, likely to be the origin of the sterilizing effect, is detected through their UV emission lines. The effect of the UV and the OH radicals on the fibroblasts was analysed and no significant effects were detected.

  7. A Review on Inductively Coupled Plasma Mass Spectroscopy

    Directory of Open Access Journals (Sweden)

    Ramyalakshmi G

    2012-12-01

    Full Text Available Inductively coupled plasma mass spectroscopy is routinely used in many diverse research fields such as earth, environmental, life and forensic sciences and in food, material, chemical, semiconductor and nuclear industries. The high ion density and the high temperature in a plasma provide an ideal atomizer and element ionizer for all types of samples and materials introduced by a specialised devices .outstanding properties such as high sensitivity, relative salt tolerance, compound-independent element response and highest quantitation accuracy lead to the unchallenged performance of ICPMS in efficiently detecting, identifying and reliably quantifying trace element. The increasing availability of relevant reference compounds and high separation selectively extend the molecular identification capability of ICPMS hyphenated to species – specific separation techniques

  8. Plant Phosphoproteomics: Analysis of Plasma Membrane Transporters by Mass Spectrometry

    DEFF Research Database (Denmark)

    Ye, Juanying; Rudashevskaya, Elena; Young, Clifford

    important physiological functions, such as stomata aperture, cell elongation, or cellular pH regulation. It is known that the activity of plant plasma membrane H+-ATPase is regulated by phosphorylation. Therefore, we first investigated the phosphorylation profile of plant H+-ATPase by enriching...... the phosphopeptides with optimized TiO2 and IMAC enrichment methods prior to MS analysis. We further investigated the global phosphorylation profile of the whole plant plasma membrane proteins using the combination of our recently established phosphopeptide enrichment method, Calcium phosphate precipitation......  Phosphorylation is a key regulatory factor in all aspects of eukaryotic biology including the regulation of plant membrane-bound transport proteins. To date, mass spectrometry (MS) has been introduced as powerful technology for study of post translational modifications (PTMs), including protein...

  9. Applications of plasma sources for nitric oxide medicine

    Science.gov (United States)

    Vasilets, Victor; Shekhter, Anatoly; Pekshev, Alexander

    2013-09-01

    Nitric oxide (NO) has important roles in the function of many tissues and organs. Wound healing processes are always accompanying by the increase of nitric oxide concentration in wound tissue. These facts suggest a possible therapeutic use of various NO donors for the acceleration of the wound healing and treatment of other diseases. Our previous studies indicated that gaseous NO flow produced by air-plasma generators acts beneficially on the wound healing. This beneficial effect could be caused by the mechanism involving peroxynitrite as an intermediate. As a result of mobilization of various antioxidant reactions more endogenous NO molecules become available as signaling molecules. to regulate the metabolic processes in wound tissue. In this paper different air plasma sources generated therapeutic concentrations of NO are discussed. The concentration of NO and other therapeutically important gas products are estimated by thermodynamic simulation. Synergy effects of NO with other plasma components are discussed as a factor enhancing therapeutic results. Some new medical application of plasma devices are presented. Advanced Plasma Therapies Inc.

  10. Tin LPP plasma control in the argon cusp source

    Science.gov (United States)

    McGeoch, Malcolm W.

    2016-03-01

    The argon cusp plasma has been introduced [1,2] for 500W class tin LPP exhaust control in view of its high power handling, predicted low tin back-scatter from a beam dump, and avoidance of hydrogen usage. The physics of tin ion control by a plasma is first discussed. Experimentally, cusp stability and exhaust disc geometry have previously been proved at full scale [2], the equivalent of 300W-500W usable EUV. Here we verify operation of the plasma barrier that maintains a high argon density next to the collector, for its protection, and a low density in the long path toward the intermediate focus, for efficiency. A pressure differential of 2Pa has been demonstrated in initial work. Other aspects of tin LPP plasma control by the cusp have now been demonstrated using tin ions from a low Hz 130mJ CO2 laser pulse onto a solid tin surface at the cusp center. Plasma is rejected at the design to match a specified exhaust power is discussed. In view of this work, argon cusp exhaust control appears to be very promising for 500W class tin LPP sources.

  11. Sheath overlap during very large scale plasma source ion implantation

    Science.gov (United States)

    Cluggish, B. P.; Munson, C. P.

    1998-12-01

    Measurements of plasma source ion implantation have been performed on a large target of complex geometry. The target consists of 1000 aluminum, automotive piston surrogates mounted on four racks; total surface area is over 16 m2. The four racks are positioned parallel to each other, 0.25 m apart, in an 8 m3 vacuum chamber. The racks of pistons are immersed in a capacitive radio frequency plasma, with an argon gas pressure of 20-65 mPa. Langmuir probe measurements indicate that the plasma density profile is highly nonuniform, due to particle losses to the racks of pistons. The plasma ions are implanted into the pistons by pulse biasing the workpiece to negative voltages as low as -18 kV for up to 20 μs. During the voltage pulse, the high-voltage sheaths from adjacent racks of pistons converge towards each other. At plasma densities less than 109 cm-3 the sheaths are observed to overlap. Measurements of the sheath overlap time are compared with standard analytic theory and with simulations run with a two-dimensional particle-in-cell code.

  12. A microwave plasma source for VUV atmospheric photochemistry

    OpenAIRE

    Tigrine, Sarah; Carrasco, Nathalie; Vettier, Ludovic; Cernogora, Guy

    2017-01-01

    International audience; Microwave plasma discharges working at low pressure are nowadays a well-developed technique mainly used to provide radiations at different wavelengths. The aim of this work is to show that those discharges are an efficient windowless VUV photon source for planetary atmospheric photochemistry experiments. To do this, we use a surfatron-type discharge with a neon gas flow in the mbar pressure range coupled to a photochemical reactor. Working in the VUV range allows to fo...

  13. High Current, High Density Arc Plasma as a New Source for WiPAL

    Science.gov (United States)

    Waleffe, Roger; Endrizzi, Doug; Myers, Rachel; Wallace, John; Clark, Mike; Forest, Cary; WiPAL Team

    2016-10-01

    The Wisconsin Plasma Astrophysics Lab (WiPAL) has installed a new array of nineteen plasma sources (plasma guns) on its 3 m diameter, spherical vacuum vessel. Each gun is a cylindrical, molybdenum, washer-stabilized, arc plasma source. During discharge, the guns are maintained at 1.2 kA across 100 V for 10 ms by the gun power supply establishing a high density plasma. Each plasma source is fired independently allowing for adjustable plasma parameters, with densities varying between 1018 -1019 m-3 and electron temperatures of 5-15 eV. Measurements were characterized using a 16 tip Langmuir probe. The plasma source will be used as a background plasma for the magnetized coaxial plasma gun (MCPG), the Terrestrial Reconnection Experiment (TREX), and as the plasma source for a magnetic mirror experiment. Temperature, density, and confinement results will be presented. This work is supported by the DoE and the NSF.

  14. Improvement in brightness of multicusp-plasma ion source

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Q.; Jiang, X.; King, T-J.; Leung, K-N.; Standiford, K.; Wilde, S.B.

    2002-05-24

    The beam brightness of a multicusp-plasma ion source has been substantially improved by optimizing the source configuration and extractor geometry. The current density of a 2 keV He{sup +} beam extracted from a 7.5-cm-diameter source operating at 2.5 kW RF power is {approx}100 mA/cm{sup 2}, which is {approx}10 times larger than that of a beam extracted from a 5-cm-diameter source operating at 1 kW RF power. A smaller focused beam spot size is achieved with a counter-bored extractor instead of a conventional (''through-hole'') extractor, resulting another order of magnitude improvement in beam current density. Measured brightness can be as high as 440 A/cm{sup 2}Sr, which represents a 30 times improvement over prior work.

  15. Efficient cesiation in RF driven surface plasma negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Belchenko, Yu.; Ivanov, A.; Konstantinov, S.; Sanin, A., E-mail: sanin@inp.nsk.su; Sotnikov, O. [Budker Institute of Nuclear Physics, Siberian Branch of Russian Academy of Sciences, Novosibirsk (Russian Federation)

    2016-02-15

    Experiments on hydrogen negative ions production in the large radio-frequency negative ion source with cesium seed are described. The system of directed cesium deposition to the plasma grid periphery was used. The small cesium seed (∼0.5 G) provides an enhanced H{sup −} production during a 2 month long experimental cycle. The gradual increase of negative ion yield during the long-term source runs was observed after cesium addition to the source. The degraded H{sup −} production was recorded after air filling to the source or after the cesium washing away from the driver and plasma chamber walls. The following source conditioning by beam shots produces the gradual recovery of H{sup −} yield to the high value. The effect of H{sup −} yield recovery after cesium coverage passivation by air fill was studied. The concept of cesium coverage replenishment and of H{sup −} yield recovery due to sputtering of cesium from the deteriorated layers is discussed.

  16. High Power Light Gas Helicon Plasma Source For VASMIR

    Science.gov (United States)

    Squire, J. P.; Chang-Diaz, F. R.; Glover, T. W.; Jacobson, V. T.; McCaskill, G. E.; Winter, D. S.; Baity, F. W.; Carter, M. D.; Goulding, R. H.

    2004-01-01

    The VASIMR space propulsion development effort relies on a high power (greater than 10kW) helicon source to produce a dense flowing plasma (H, D and He) target for ion cyclotron resonance (ICR) acceleration of the ions. Subsequent expansion in an expanding magnetic field (magnetic nozzle) converts ion lunetic energy to directed momentum. This plasma source must have critical features to enable an effective propulsion device. First, it must ionize most of the input neutral flux of gas, thus producing a plasma stream with a high degree of ionization for application of ICR power. This avoids propellant waste and potential power losses due to charge exchange. Next, the plasma stream must flow into a region of high magnetic field (approximately 0.5 T) for efficient ICR acceleration. Third, the ratio of input power to plasma flux must be low, providing an energy per ion-electron pair approaching 100 eV. Lastly, the source must be robust and capable of very long life-times (years). In our helicon experiment (VX-10) we have measured a ratio of input gas to plasma flux near 100%. The plasma flows from the helicon region (B approximately 0.1 T) into a region with a peak magnetic field of 0.8 T. The energy input per ion-electron pair has been measured at 300 plus or minus 100 eV. Recent results at Oak Ridge National Laboratory (ORNL) show an enhanced efficiency mode of operation with a high power density, over 5 kW in a 5 cm diameter tube. Our helicon is presently 9 cm in diameter and operates up to 3.5 kW of input power. An upgrade to a power level of 10 kW is underway. Much of our recent work has been with a Boswell double-saddle antenna design. We are also converting the antenna design to a helical type. With these modifications, we anticipate an improvement in the ionization efficiency. This paper presents the results from scaling the helicon in the VX-10 device from 3.5 to 10 kW. We also compare the operation with a double-saddle to a helical antenna design. Finally, we

  17. High Power Light Gas Helicon Plasma Source For VASMIR

    Science.gov (United States)

    Squire, J. P.; Chang-Diaz, F. R.; Glover, T. W.; Jacobson, V. T.; McCaskill, G. E.; Winter, D. S.; Baity, F. W.; Carter, M. D.; Goulding, R. H.

    2004-01-01

    The VASIMR space propulsion development effort relies on a high power (greater than 10kW) helicon source to produce a dense flowing plasma (H, D and He) target for ion cyclotron resonance (ICR) acceleration of the ions. Subsequent expansion in an expanding magnetic field (magnetic nozzle) converts ion lunetic energy to directed momentum. This plasma source must have critical features to enable an effective propulsion device. First, it must ionize most of the input neutral flux of gas, thus producing a plasma stream with a high degree of ionization for application of ICR power. This avoids propellant waste and potential power losses due to charge exchange. Next, the plasma stream must flow into a region of high magnetic field (approximately 0.5 T) for efficient ICR acceleration. Third, the ratio of input power to plasma flux must be low, providing an energy per ion-electron pair approaching 100 eV. Lastly, the source must be robust and capable of very long life-times (years). In our helicon experiment (VX-10) we have measured a ratio of input gas to plasma flux near 100%. The plasma flows from the helicon region (B approximately 0.1 T) into a region with a peak magnetic field of 0.8 T. The energy input per ion-electron pair has been measured at 300 plus or minus 100 eV. Recent results at Oak Ridge National Laboratory (ORNL) show an enhanced efficiency mode of operation with a high power density, over 5 kW in a 5 cm diameter tube. Our helicon is presently 9 cm in diameter and operates up to 3.5 kW of input power. An upgrade to a power level of 10 kW is underway. Much of our recent work has been with a Boswell double-saddle antenna design. We are also converting the antenna design to a helical type. With these modifications, we anticipate an improvement in the ionization efficiency. This paper presents the results from scaling the helicon in the VX-10 device from 3.5 to 10 kW. We also compare the operation with a double-saddle to a helical antenna design. Finally, we

  18. Fundamental studies of the plasma extraction and ion beam formation processes in inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Niu, Hongsen

    1995-02-10

    The fundamental and practical aspects are described for extracting ions from atmospheric pressure plasma sources into an analytical mass spectrometer. Methodologies and basic concepts of inductively coupled plasma mass spectrometry (ICP-MS) are emphasized in the discussion, including ion source, sampling interface, supersonic expansion, slumming process, ion optics and beam focusing, and vacuum considerations. Some new developments and innovative designs are introduced. The plasma extraction process in ICP-MS was investigated by Langmuir measurements in the region between the skimmer and first ion lens. Electron temperature (T{sub e}) is in the range 2000--11000 K and changes with probe position inside an aerosol gas flow. Electron density (n{sub e}) is in the range 10{sup 8}--10{sup 10} {sup {minus}cm }at the skimmer tip and drops abruptly to 10{sup 6}--10{sup 8} cm{sup {minus}3} near the skimmer tip and drops abruptly to 10{sup 6}--10{sup 8} cm{sup {minus}3} downstream further behind the skimmer. Electron density in the beam leaving the skimmer also depends on water loading and on the presence and mass of matrix elements. Axially resolved distributions of electron number-density and electron temperature were obtained to characterize the ion beam at a variety of plasma operating conditions. The electron density dropped by a factor of 101 along the centerline between the sampler and skimmer cones in the first stage and continued to drop by factors of 10{sup 4}--10{sup 5} downstream of skimmer to the entrance of ion lens. The electron density in the beam expansion behind sampler cone exhibited a 1/z{sup 2} intensity fall-off (z is the axial position). An second beam expansion originated from the skimmer entrance, and the beam flow underwent with another 1/z{sup 2} fall-off behind the skimmer. Skimmer interactions play an important role in plasma extraction in the ICP-MS instrument.

  19. Fissile mass estimation by pulsed neutron source interrogation

    Energy Technology Data Exchange (ETDEWEB)

    Israelashvili, I., E-mail: israelashvili@gmail.com [Nuclear Research Center of the Negev, P.O.B 9001, Beer Sheva 84190 (Israel); Dubi, C.; Ettedgui, H.; Ocherashvili, A. [Nuclear Research Center of the Negev, P.O.B 9001, Beer Sheva 84190 (Israel); Pedersen, B. [Nuclear Security Unit, Institute for Transuranium Elements, Joint Research Centre, Via E. Fermi, 2749, 21027 Ispra (Italy); Beck, A. [Nuclear Research Center of the Negev, P.O.B 9001, Beer Sheva 84190 (Israel); Roesgen, E.; Crochmore, J.M. [Nuclear Security Unit, Institute for Transuranium Elements, Joint Research Centre, Via E. Fermi, 2749, 21027 Ispra (Italy); Ridnik, T.; Yaar, I. [Nuclear Research Center of the Negev, P.O.B 9001, Beer Sheva 84190 (Israel)

    2015-06-11

    Passive methods for detecting correlated neutrons from spontaneous fissions (e.g. multiplicity and SVM) are widely used for fissile mass estimations. These methods can be used for fissile materials that emit a significant amount of fission neutrons (like plutonium). Active interrogation, in which fissions are induced in the tested material by an external continuous source or by a pulsed neutron source, has the potential advantages of fast measurement, alongside independence of the spontaneous fissions of the tested fissile material, thus enabling uranium measurement. Until recently, using the multiplicity method, for uranium mass estimation, was possible only for active interrogation made with continues neutron source. Pulsed active neutron interrogation measurements were analyzed with techniques, e.g. differential die away analysis (DDA), which ignore or implicitly include the multiplicity effect (self-induced fission chains). Recently, both, the multiplicity and the SVM techniques, were theoretically extended for analyzing active fissile mass measurements, made by a pulsed neutron source. In this study the SVM technique for pulsed neutron source is experimentally examined, for the first time. The measurements were conducted at the PUNITA facility of the Joint Research Centre in Ispra, Italy. First promising results, of mass estimation by the SVM technique using a pulsed neutron source, are presented.

  20. Quantitative aspects of inductively coupled plasma mass spectrometry

    Science.gov (United States)

    Bulska, Ewa; Wagner, Barbara

    2016-10-01

    Accurate determination of elements in various kinds of samples is essential for many areas, including environmental science, medicine, as well as industry. Inductively coupled plasma mass spectrometry (ICP-MS) is a powerful tool enabling multi-elemental analysis of numerous matrices with high sensitivity and good precision. Various calibration approaches can be used to perform accurate quantitative measurements by ICP-MS. They include the use of pure standards, matrix-matched standards, or relevant certified reference materials, assuring traceability of the reported results. This review critically evaluates the advantages and limitations of different calibration approaches, which are used in quantitative analyses by ICP-MS. Examples of such analyses are provided. This article is part of the themed issue 'Quantitative mass spectrometry'.

  1. Switched ferroelectric plasma ionizer (SwiFerr) for ambient mass spectrometry.

    Science.gov (United States)

    Neidholdt, Evan L; Beauchamp, J L

    2011-01-01

    We present the implementation of a switched ferroelectric plasma ionizer (SwiFerr) for ambient analysis of trace substances by mass spectrometry. The device utilizes the ferroelectric properties of barium titanate (BaTiO(3)) to take advantage of the high electric field resulting from polarization switching in the material. The source comprises a [001]-oriented barium titanate crystal (5 × 5 × 1 mm) with a metallic rear electrode and a metallic grid front electrode. When a high voltage AC waveform is applied to the rear electrode to switch polarization, the resulting electric field on the face of the crystal promotes electron emission and results in plasma formation between the crystal face and the grounded grid at ambient pressure. Interaction with this plasma and the resulting reagent ions effects ionization of trace neutrals. The source requires less than 1 W of power to operate under most circumstances, ionizes molecules with acidic and basic functional groups easily, and has proven quite versatile for ambient analysis of both vapor phase and aspirated powdered solid samples. Ionization of vapor phase samples of the organics triethylamine, tripropylamine, tributylamine, and pyridine results in observation of the singly protonated species in the positive ion mass spectrum with sensitivity extending into the high ppb range. With acetic acid, deprotonated clusters dominate the negative ion mass spectrum. Aerodynamic sampling of powdered samples is used to record mass spectra of the pharmaceuticals loperamide and ibuprofen. Chemical signatures, including protonated loperamide and deprotonated ibuprofen, are observed for each drug. The robust, low power source lends itself easily to miniaturization and incorporation in field-portable devices used for the rapid detection and characterization of trace substances and hazardous materials in a range of different environments.

  2. Dynamics of Ion Beam Charge Neutralization by Ferroelectric Plasma Sources

    Science.gov (United States)

    Stepanov, Anton D.; Gilson, Erik P.; Grisham, Larry R.; Kaganovich, Igor D.; Davidson, Ronald C.; Ji, Qing; Persaud, Arun; Seidl, Peter A.; Schenkel, Thomas

    2016-10-01

    Ferroelectric Plasma Sources (FEPSs) can generate plasma that provides effective space-charge neutralization of intense high-perveance ion beams. Here we present experimental results on charge neutralization of a high-perveance 38 keV Ar+ beam by a FEPS plasma. By comparing the measured beam radius with the envelope model for space-charge expansion, it is shown that a charge neutralization fraction of 98% is attainable. The transverse electrostatic potential of the ion beam is reduced from 15 V before neutralization to 0.3 V, implying that the energy of the neutralizing electrons is below 0.3 eV. Near-complete charge neutralization is established 5 μs after the driving pulse is applied to the FEPS, and can last for 35 μs. It is argued that the duration of neutralization is much longer than a reasonable lifetime of the plasma produced in the sub- μs surface discharge. Measurements of current flow in the driving circuit of the FEPS suggest that plasma can be generated for tens of μs after the high voltage pulse is applied. This is confirmed by fast photography of the plasma in the 1-meter long FEPS on NDCX-II, where effective charge neutralization of the beam was achieved with the optimized FEPS timing. This work was supported by the Office of Science of the US Department of Energy under contracts DE-AC0209CH11466 (PPPL) and DE-AC0205CH11231 (LBNL).

  3. New Types of Ionization Sources for Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    None

    2008-12-01

    The purpose of this Cooperative Research and Development Agreement (CRADA) between UT-Battelle (Contractor) and MDS Sciex (Participant) and ESA, Inc. (Participant) is to research, develop and apply new types of ionization sources and sampling/inlet systems for analytical mass spectrometry making use of the Participants state-of-the-art atmospheric sampling mass spectrometry electrochemical cell technology instrumentation and ancillary equipment. The two overriding goals of this research project are: to understand the relationship among the various instrumental components and operational parameters of the various ion sources and inlet systems under study, the chemical nature of the gases, solvents, and analytes in use, and the nature and abundances of the ions ultimately observed in the mass spectrometer; and to develop new and better analytical and fundamental applications of these ion sources and inlet systems or alternative sources and inlets coupled with mass spectrometry on the basis of the fundamental understanding obtained in Goal 1. The end results of this work are expected to be: (1) an expanded utility for the ion sources and inlet systems under study (such as the analysis of new types of analytes) and the control or alteration of the ionic species observed in the gas-phase; (2) enhanced instrument performance as judged by operational figures-of-merit such as dynamic range, detection limits, susceptibility to matrix signal suppression and sensitivity; and (3) novel applications (such as surface sampling with electrospray) in both applied and fundamental studies. The research projects outlined herein build upon work initiated under the previous CRADA between the Contractor and MDS Sciex on ion sources and inlet systems for mass spectrometry. Specific ion source and inlet systems for exploration of the fundamental properties and practical implementation of these principles are given.

  4. Deposition and sputtering yields on EUV collector mirror from Laser Plasma Extreme Ultraviolet Sources

    Energy Technology Data Exchange (ETDEWEB)

    Wu Tao [Wuhan National Laboratory for Optoelectronics, School of Optoelectronic Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China); Rao Zhiming [Depart of Computer Science, Jiangxi University of Traditional Chinese Medicine, Nanchang 330004, Jiangxi (China); Wang Shifang, E-mail: flatime@163.com [School of Physics and Electric Information, Hubei University of Education 1 Nanhuan Road, Wuhan East High-Tech. Zone, Wuhan 430205, Hubei (China)

    2011-02-01

    Based on the self-similar solution of gas dynamic equations, spherical expansion of the highly ionized plasma with limited mass into a vacuum is investigated for the droplet target laser-produced plasma extreme ultraviolet (LPP-EUV) sources. Using partially numerical and partially analytical technology, the velocity, the temperature and the density profiles in the plume versus ionization degree, adiabatic index and initial conditions are presented. Furthermore, the spatial thickness variations of the deposited substrate witness and ion sputtering yields for Ru, Mo, and Si under Sn ion bombardment are theoretically calculated, which can be useful to enable LPP-EUV sources suppliers to estimate collector lifetime and improve debris mitigation systems.

  5. Modeling and measuring the transport and scattering of energetic debris in an extreme ultraviolet plasma source

    Science.gov (United States)

    Sporre, John R.; Elg, Daniel T.; Kalathiparambil, Kishor K.; Ruzic, David N.

    2016-01-01

    A theoretical model for describing the propagation and scattering of energetic species in an extreme ultraviolet (EUV) light lithography source is presented. An EUV light emitting XTREME XTS 13-35 Z-pinch plasma source is modeled with a focus on the effect of chamber pressure and buffer gas mass on energetic ion and neutral debris transport. The interactions of the energetic debris species, which is generated by the EUV light emitting plasma, with the buffer gas and chamber walls are considered as scattering events in the model, and the trajectories of the individual atomic species involved are traced using a Monte Carlo algorithm. This study aims to establish the means by which debris is transported to the intermediate focus with the intent to verify the various mitigation techniques currently employed to increase EUV lithography efficiency. The modeling is compared with an experimental investigation.

  6. Extraction of ions and electrons from audio frequency plasma source

    Directory of Open Access Journals (Sweden)

    N. A. Haleem

    2016-09-01

    Full Text Available Herein, the extraction of high ion / electron current from an audio frequency (AF nitrogen gas discharge (10 – 100 kHz is studied and investigated. This system is featured by its small size (L= 20 cm and inner diameter = 3.4 cm and its capacitive discharge electrodes inside the tube and its high discharge pressure ∼ 0.3 Torr, without the need of high vacuum system or magnetic fields. The extraction system of ion/electron current from the plasma is a very simple electrode that allows self-beam focusing by adjusting its position from the source exit. The working discharge conditions were applied at a frequency from 10 to 100 kHz, power from 50 – 500 W and the gap distance between the plasma meniscus surface and the extractor electrode extending from 3 to 13 mm. The extracted ion/ electron current is found mainly dependent on the discharge power, the extraction gap width and the frequency of the audio supply. SIMION 3D program version 7.0 package is used to generate a simulation of ion trajectories as a reference to compare and to optimize the experimental extraction beam from the present audio frequency plasma source using identical operational conditions. The focal point as well the beam diameter at the collector area is deduced. The simulations showed a respectable agreement with the experimental results all together provide the optimizing basis of the extraction electrode construction and its parameters for beam production.

  7. 77 FR 7 - Revisions to Labeling Requirements for Blood and Blood Components, Including Source Plasma

    Science.gov (United States)

    2012-01-03

    ...) Revisions to Labeling Requirements for Blood and Blood Components, Including Source Plasma AGENCY: Food and... requirements for blood and blood components, including Source Plasma, into one section of the Code of Federal..., and Source Plasma,'' which amended Sec. 606.121(d)(2) by adding ``or in solid black,''...

  8. Serum/plasma methylmercury determination by isotope dilution gas chromatography-inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Douglas C., E-mail: douglas.baxter@alsglobal.com [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Faarinen, Mikko [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Osterlund, Helene; Rodushkin, Ilia [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Division of Geosciences, Lulea University of Technology, 977 87 Lulea (Sweden); Christensen, Morten [ALS Scandinavia AB, Maskinvaegen 2, 183 53 Taeby (Sweden)

    2011-09-09

    Highlights: {center_dot} We determine methylmercury in serum and plasma using isotope dilution calibration. {center_dot} Separation by gas chromatography and detection by inductively coupled plasma mass spectrometry. {center_dot} Data for 50 specimens provides first reference range for methylmercury in serum. {center_dot} Serum samples shown to be stable for 11 months in refrigerator. - Abstract: A method for the determination of methylmercury in plasma and serum samples was developed. The method uses isotope dilution with {sup 198}Hg-labeled methylmercury, extraction into dichloromethane, back-extraction into water, aqueous-phase ethylation, purge and trap collection, thermal desorption, separation by gas chromatography, and mercury isotope specific detection by inductively coupled plasma mass spectrometry. By spiking 2 mL sample with 1.2 ng tracer, measurements in a concentration interval of (0.007-2.9) {mu}g L{sup -1} could be performed with uncertainty amplification factors <2. A limit of quantification of 0.03 {mu}g L{sup -1} was estimated at 10 times the standard deviation of concentrations measured in preparation blanks. Within- and between-run relative standard deviations were <10% at added concentration levels of 0.14 {mu}g L{sup -1}, 0.35 {mu}g L{sup -1} and 2.8 {mu}g L{sup -1}, with recoveries in the range 82-110%. Application of the method to 50 plasma/serum samples yielded a median (mean; range) concentration of methylmercury of 0.081 (0.091; <0.03-0.19) {mu}g L{sup -1}. This is the first time methylmercury has been directly measured in this kind of specimen, and is therefore the first estimate of a reference range.

  9. A compact and continuously driven supersonic plasma and neutral source.

    Science.gov (United States)

    Asai, T; Itagaki, H; Numasawa, H; Terashima, Y; Hirano, Y; Hirose, A

    2010-10-01

    A compact and repetitively driven plasma source has been developed by utilizing a magnetized coaxial plasma gun (MCPG) for diagnostics requiring deep penetration of a large amount of neutral flux. The system consists of a MCPG 95mm in length with a DN16 ConFlat connection port and an insulated gate bipolar transistor (IGBT) inverter power unit. The power supply consists of an array of eight IGBT units and is able to switch the discharge on and off at up to 10 kV and 600 A with a maximum repetitive frequency of 10 kHz. Multiple short duration discharge pulses maximize acceleration efficiency of the plasmoid. In the case of a 10 kHz operating frequency, helium-plasmoids in the velocity range of 20 km/s can be achieved.

  10. Plasma Desorption Mass Spectrometry analysis of HCOOH ice

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, D.P.P.; Rocco, M.L.M. [Departamento de Fisico-Quimica, Instituto de Quimica, Universidade Federal do Rio de Janeiro, Cidade Universitaria, Ilha do Fundao, 21949-900 Rio de Janeiro, RJ (Brazil); Boechat-Roberty, H.M. [Observatorio do Valongo, Universidade Federal do Rio de Janeiro, Ladeira Pedro Antonio, 43, Centro, Rio de Janeiro, RJ (Brazil); Iza, P.; Martinez, R. [Departamento de Fisica, Pontificia Universidade Catolica do Rio de Janeiro, 22543-900 Rio de Janeiro (Brazil); Homem, M.G.P. [Laboratorio Nacional de Luz Sincrotron (LNLS), Box 6192, 13084-971 Campinas, SP (Brazil); Silveira, E.F. da [Departamento de Fisica, Pontificia Universidade Catolica do Rio de Janeiro, 22543-900 Rio de Janeiro (Brazil)], E-mail: enio@vdg.fis.puc-rio.br

    2007-03-15

    Planetary magnetospheres, in which outer planet satellites orbit, are bombarded by energetic particles inducing chemical and physical changes in their icy surfaces. The existing condensed gases react to form new products, which then undergo thermal evolution from the natural day/night cycles of these satellites. Plasma irradiation of ice causes phase changes, e.g., water ice from crystalline to amorphous over short timescales. When ice is recrystallized by heating, the surface layers retain some disorder, which promote reactions among adsorbed molecules such as H{sub 2}O, CO{sub 2}, CH{sub 2}CO, HCOOH and theirs radiolysis products. In this work, chemical reactions involving formic acid condensed at 56 K are analyzed by using Plasma Desorption Mass Spectrometry-time-of-flight ({sup 252}Cf-PDMS-TOF). Mass spectra of positive and negative desorbed ions were obtained, giving information on the structure and abundance of the molecules on the ice; the expected cations and anions generated by the HCOOH dissociation have been observed. Furthermore, several series of cluster ions were also detected, all exhibiting the structure X{sub n}Y{sub m}R{sup {+-}}, where X and Y are the neutral ice molecules, such as HCOOH or H{sub 2}O, and R{sup {+-}} is either an atomic or a molecular ion, such as H{sup +}, H{sub 3}O{sup +} or COOH{sup -}. In general, the desorption yields of the observed positive and negative ions are characterized by a decreasing exponential function as the emitted ion mass increases; however, the (HCOOH){sub n}OH{sup -} series presents its maximum at n = 8.

  11. High Resolution Studies of the Origins of Polyatomic Ions in Inductively Coupled Plasma-Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ferguson, Jill Wisnewski [Iowa State Univ., Ames, IA (United States)

    2006-01-01

    The inductively coupled plasma (ICP) is an atmospheric pressure ionization source. Traditionally, the plasma is sampled via a sampler cone. A supersonic jet develops behind the sampler, and this region is pumped down to a pressure of approximately one Torr. A skimmer cone is located inside this zone of silence to transmit ions into the mass spectrometer. The position of the sampler and skimmer cones relative to the initial radiation and normal analytical zones of the plasma is key to optimizing the useful analytical signal [1]. The ICP both atomizes and ionizes the sample. Polyatomic ions form through ion-molecule interactions either in the ICP or during ion extraction [l]. Common polyatomic ions that inhibit analysis include metal oxides (MO+), adducts with argon, the gas most commonly used to make up the plasma, and hydride species. While high resolution devices can separate many analytes from common interferences, this is done at great cost in ion transmission efficiency--a loss of 99% when using high versus low resolution on the same instrument [2]. Simple quadrupole devices, which make up the bulk of ICP-MS instruments in existence, do not present this option. Therefore, if the source of polyatomic interferences can be determined and then manipulated, this could potentially improve the figures of merit on all ICP-MS devices, not just the high resolution devices often utilized to study polyatomic interferences.

  12. Plasma expansion across a transverse magnetic field in a negative hydrogen ion source for fusion

    Science.gov (United States)

    Fantz, U.; Schiesko, L.; Wünderlich, D.

    2014-08-01

    High power negative hydrogen ion sources operating at 0.3 Pa are a key component of the neutral beam injection systems for the international fusion experiment ITER. To achieve the required large ion current at a tolerable number of co-extracted electrons the source is equipped with a magnetic filter field (up to 10 mT). The IPP prototype source (1/8 of the area of the ITER source) has been equipped with a flexible magnetic filter frame to perform filter field studies (position, polarity, strength). Axial profiles of the plasma parameters are measured with two Langmuir probes, positioned in the upper and the lower half of the expansion chamber. In addition to the expected decrease in electron temperature and density a vertical drift develops the direction depending on the polarity of the field. Without field no drift is observed. The drift is less pronounced in caesium seeded discharges and almost vanishes in deuterium, indicating an influence of the ion mass on the drift. A comparison with results from a half-size ITER source reveals that the plasma is much more uniform in the large source.

  13. Precise Measurement of Separation Between Two Spherical Source Masses

    Institute of Scientific and Technical Information of China (English)

    陈德才; 罗俊; 胡忠坤; 赵亮

    2004-01-01

    A driving gauge method is performed to determine the separation between two spherical source masses in the measurement of Newtonian gravitational constant G. The experimental result shows that the uncertainty of determining the separation is about 0.35μm, which would contribute an uncertainty of 7.3ppm to the value of G.

  14. Characteristics and potential applications of an ORNL microwave ECR multicusp plasma ion source

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, C.C.

    1990-01-01

    A new microwave electron cyclotron resonance (ECR) multicusp plasma ion source that has two ECR plasma production regions and uses multicusp plasma confinement has been developed at Oak Ridge National Laboratory. This source has been operated to produce uniform and dense plasma over large areas of 300 to 400 cm{sup 2} and could be scaled up to produce uniform plasma over 700 cm{sup 2} or larger. The plasma source has been operated with continuous argon gas feed and pulsed microwave power. The working gases used were argon, helium, hydrogen, and oxygen. The discharge initiation phenomena and plasma properties have been investigated and studied as functions of the discharge parameters. The discharge characteristics and a hypothetical discharge mechanism for this plasma source are described and discussed. Potential applications, including plasma and ion-beam sources for manufacturing advanced microelectronics, for space electric propulsion, and for fusion research, are discussed. 10 refs., 10 figs.

  15. Nanoscale imaging using a compact laser plasma EUV source

    Science.gov (United States)

    Wachulak, Przemyslaw; Bartnik, Andrzej; Fiedorowicz, Henryk; Kostecki, Jerzy; Jarocki, Roman; Szczurek, Miroslaw; Szczurek, Anna; Feigl, Torsten; Pina, Ladislav

    2012-05-01

    High resolution imaging methods and techniques are currently under development. One of them is an extreme ultraviolet (EUV) microscopy, based on Fresnel zone plates. In this paper a compact, high-repetition, laser-plasma EUV source, emitting quasi-monochromatic radiation at 13.8nm wavelength was used in a desktop EUV transmission microscopy with a spatial (half-pitch) resolution of 50nm. EUV microscopy images of objects with various thicknesses and the spatial resolution measurements using the knife-edge test are presented.

  16. Focused ion beams using a high-brightness plasma source

    Science.gov (United States)

    Guharay, Samar

    2002-10-01

    High-brightness ion beams, with low energy spread, have merits for many new applications in microelectronics, materials science, and biology. Negative ions are especially attractive for the applications that involve beam-solid interactions. When negative ions strike a surface, especially an electrically isolated surface, the surface charging voltage is limited to few volts [1]. This property can be effectively utilized to circumvent problems due to surface charging, such as device damage and beam defocusing. A compact plasma source, with the capability to deliver either positive or negative ion beams, has been developed. H- beams from this pulsed source showed brightness within an order of magnitude of the value for beams from liquid-metal ion sources. The beam angular intensity is > 40 mAsr-1 and the corresponding energy spread is 1 Acm-2 and a spot size of 100 nm. Such characteristics of focused beam parameters, using a dc source, will immediately open up a large area of new applications. [1] P. N. Guzdar, A. S. Sharma, S. K. Guharay, "Charging of substrates irradiated by particle beams" Appl. Phys. Lett. 71, 3302 (1997). [2] S. K. Guharay, E. Sokolovsky, J. Orloff, "Characteristics of ion beams from a Penning source for focused ion beam applications" J. Vac. Sci Technol. B17, 2779 (1999).

  17. Study of negative ion transport phenomena in a plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Riz, D.; Pamela, J. [Departement de Recherches sur la Fusion Controlee C. E., Cadarache, 13108 St-Paul-lez-Durance Cedex (France)

    1996-07-01

    NIETZSCHE (Negative Ions Extraction and Transport ZSimulation Code for HydrogEn species) is a negative ion (NI) transport code developed at Cadarache. This code calculates NI trajectories using a 3D Monte-Carlo technique, taking into account the main destruction processes, as well as elastic collisions (H{sup {minus}}/H{sup +}) and charge exchanges (H{sup {minus}}/H{sup 0}). It determines the extraction probability of a NI created at a given position. According to the simulations, we have seen that in the case of volume production, only NI produced close to the plasma grid (PG) can be extracted. Concerning the surface production, we have studied how NI produced on the PG and accelerated by the plasma sheath backward into the source could be extracted. We demonstrate that elastic collisions and charge exchanges play an important role, which in some conditions dominates the magnetic filter effect, which acts as a magnetic mirror. NI transport in various conditions will be discussed: volume/surface production, high/low plasmas density, tent filter/transverse filter. {copyright} {ital 1996 American Institute of Physics.}

  18. Study of negative ion transport phenomena in a plasma source

    Science.gov (United States)

    Riz, D.; Paméla, J.

    1996-07-01

    NIETZSCHE (Negative Ions Extraction and Transport ZSimulation Code for HydrogEn species) is a negative ion (NI) transport code developed at Cadarache. This code calculates NI trajectories using a 3D Monte-Carlo technique, taking into account the main destruction processes, as well as elastic collisions (H-/H+) and charge exchanges (H-/H0). It determines the extraction probability of a NI created at a given position. According to the simulations, we have seen that in the case of volume production, only NI produced close to the plasma grid (PG) can be extracted. Concerning the surface production, we have studied how NI produced on the PG and accelerated by the plasma sheath backward into the source could be extracted. We demonstrate that elastic collisions and charge exchanges play an important role, which in some conditions dominates the magnetic filter effect, which acts as a magnetic mirror. NI transport in various conditions will be discussed: volume/surface production, high/low plasmas density, tent filter/transverse filter.

  19. New supersymmetric source of neutrino masses and mixings

    CERN Document Server

    Casas, J A; Navarro, I

    2002-01-01

    Conventionally, neutrino masses in a supersymmetric theory arise from non-renormalizable lepton-number (L)-violating operators in the superpotential. The alternative possibility of having such operators in the Kahler potential as the dominant source of neutrino masses has very interesting implications and differences with respect to the standard scenario: first, the scale of L-violation can be lowered dramatically and neutrino masses have a different tan beta-dependence; second, the renormalization of these operators has remarkable properties: in many cases it improves drastically the stability of neutrino textures against radiative corrections, while in others it makes possible to generate radiatively large mixing angles in a natural way. In particular, the mass splitting and mixing angle of solar neutrinos (LAMSW solution) can be explained as a purely radiative effect.

  20. Comet plasma densities deduced from refraction of occulted radio sources

    Energy Technology Data Exchange (ETDEWEB)

    Wright, C.S. (Commonwealth Department of Science, Ionospheric Prediction Service, Narrabri, New South Wales, Australia); Nelson, G.J. (Commonwealth Scientific and Industrial Research Organization, Div. of Radiophysics, Narrabri, New South Wales, Australia)

    1979-04-01

    Observations of the occultation of radio sources by comet plasma tails are used to derive the electron density and density gradients in the tails. Occultations of source Culgoora-1 0300+16 by Comet Kohoutek and of Culgoora-1 2313-14 by Comet West were measured by radioheliograph at 80 MHz. After corrections for ionospheric refraction, a 2 arcmin anomaly was observed in the declination of 0300+16, attributed to refraction by the tail of Comet Kohoutek, while none was observed for Comet West. The maximum electron density in the tail of Comet Kohoutek is calculated to be 2 x 10 to the 4th/cu cm, while that of Comet West is 5 x 10 to the 4th/cu cm, with density gradients of about 0.05 per cu cm per km. The direction of refraction observed suggests that the tail of Kohoutek is either highly asymmetric about its axis or has the form of a hollow, cylindrical plasma sheath. The high electron densities observed in Kohoutek may indicate the presence of undetected ion species or a low ionization loss rate.

  1. Inductively coupled plasma mass spectrometry (ICP-MS)and its application in life sciences

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Inductively-coupled plasma mass spectrometry (ICP-MS) has made much progress since its birth in the late 1990s. This paper will give a rather systematic overview on the use of this technique in new devices and technologies related to plasma source, sample-introducing device and detecting spectrometer etc. In this overview, an emphasis will be put on the evaluation of the ICPMS technique in combination with a series of physical, chemical and biological techniques, such as laser ablation (LA), capillary electrophoresis (CE) and high performance liquid chromatograph (HPLC), along with their representative high accuracy and high sensitivity. Finally, comprehensive and fruitful applications of the ICP-MS and its combinative techniques in the detection of trace metallic elements and isotopes in complex biological and environmental samples will be revealed.

  2. Multicusp type Electron Cyclotron Resonance ion source for plasma processing

    Energy Technology Data Exchange (ETDEWEB)

    Amemiya, Hiroshi; Shigueoka, Yoshyuki (Institute of Physical and Chemical Research, Wako, Saitama (Japan)); Ishii, Shigeyuki

    1991-02-01

    A multi-cusp type ECR (electron cyclotron resonance) ion source is built with use of SmCo magnets and 2.45 GHz-TE{sub 11} circular mode microwave. The ion source is operated at pressures from 10{sup -4} to 10{sup -3} Torr with the input microwave power from 100 to 400 W. In hydrogen, the current density of H{sup +} is higher than those of H{sub 2}{sup +} and H{sub 3}{sup +}. The dependence of the fraction of each ion species on the power and pressure is measured and explained by rate equations. The source is operated also in other gases. Mass spectra in He, N{sub 2}, O{sub 2}, Ar and CH{sub 4} are shown together with the pressure and power dependences. Multicharged state of up to 3 has been obtained. (author).

  3. Linking Contaminant Mass Discharge to DNAPL Source Zone Architecture and Mass Removal

    Science.gov (United States)

    Pennell, K. D.; Suchomel, E. J.; Amos, B. K.; Loeffler, F. E.; Capiro, N. L.

    2007-05-01

    To evaluate the relationship between partial dense nonaqueous phase (DNAPL) mass removal and plume behavior, laboratory-scale experiments were conducted in a two-dimensional aquifer cell containing a tetrachloroethene (PCE) source zone and a down-gradient plume region. PCE-DNAPL saturation distributions were quantified using a light transmission system and expressed in terms of a ganglia-to-pool (GTP) volume ratio. To achieve incremental mass removal, the aquifer cells were flushed with a 4% Tween 80 surfactant solution that increased the solubility of PCE by more than two orders-of-magnitude with minimal mobilization of entrapped PCE-DNAPL. For a ganglia-dominated source zone (GTP = 1.6) greater than 70% mass removal was required before measurable reductions in mass discharge were realized, while for pool-dominated source zones (GTP < 0.3) reductions in mass discharge versus mass removal approached a 1:1 correlation. Current experiments are designed to evaluate the potential for coupling aggressive mass removal with microbial reductive dechlorination.

  4. When API Mass Spectrometry Meets Super Atmospheric Pressure Ion Sources.

    Science.gov (United States)

    Chen, Lee Chuin

    2015-01-01

    In a tutorial paper on the application of free-jet technique for API-MS, John Fenn mentioned that "…for a number of years and a number of reasons, it has been found advantageous in many situations to carry out the ionization process in gas at pressures up to 1000 Torr or more" (Int. J. Mass Spectrom. 200: 459-478, 2000). In fact, the first ESI mass spectrometer constructed by Yamashita and Fenn had a counter-flow curtain gas source at 1050 Torr (ca. 1.4 atm) to sweep away the neutral (J. Phys. Chem. 88: 4451-4459, 1984). For gaseous ionization using electrospray plume, theoretical analysis also shows that "super-atmospheric operation would be more preferable in space-charge-limited situations."(Int. J. Mass Spectrom. 300: 182-193, 2011). However, electrospray and the corona-based chemical ion source (APCI) in most commercial instrument are basically operated under an atmospheric pressure ambient, perhaps out of the concern of safety, convenience and simplicity in maintenance. Running the ion source at pressure much higher than 1 atm is not so common, but had been done by a number of groups as well as in our laboratory. A brief review on these ion sources will be given in this paper.

  5. The Gridless Plasma Ion Source(GIS)for Plasma Ion Assisted Optical Coating

    Institute of Scientific and Technical Information of China (English)

    尤大伟; 李晓谦; 王宇; 林永昌

    2004-01-01

    High-quality optical coating is a key technology for modern optics. Ion-assisted deposition technology was used to improve the vaporized coating in 1980's. The GIS (gridless ion source), which is an advanced plasma source for producing a high-quality optical coating in large area, can produce a large area uniformity>1000 mm(diameter), a high ion current density ~ 0.5mA/cm2, 20 eV ~ 200 eV energetic plasma ions and can activate reactive gas and film atoms. Now we have developed a GIS system. The GIS and the plasma ion-assisted deposition technology are investigated to achieve a high-quality optical coating. The GIS is a high power and high current source with a power of I kW ~ 7.5 kW, a current of 10 A ~ 70 A and an ion density of 200μA/cm2 ~ 500μA/cm2. Because of the special magnetic structure, the plasma-ion extraction efficiency has been improved to obtain a maximum ion density of 500μA/cm2 in the medium power (~ 4 kW) level. The GIS applied is of a special cathode structure, so that the GIS operation can be maintained under a rather low power and the lifetime of cathode will be extended. The GIS has been installed in the LPSX-1200 type box coating system. The coated TiO2, SiO2 films such as antireflective films with the system have the same performance reported by Leybold Co, 1992, along with a controllable refractive index and film structure.

  6. Techniques for mass resolution improvement achieved by typical plasma mass analyzers: Modeling and simulations

    Science.gov (United States)

    Nicolaou, Georgios; Yamauchi, Masatoshi; Wieser, Martin; Barabash, Stas; Fedorov, Andrei

    2016-04-01

    Mass separation and particularly distinction between atomic ions and molecular ions are essential in understanding a wide range of plasma environments, with each consisted of different species with various properties. In this study we present the optimization results of light-weight (about 2 kg) magnetic mass analyzers with high g-factor for Rosetta (Ion Composition Analyser: ICA) and for Mars Express and Venus Express (Ion Mass Analyser: IMA). For the instrument's optimization we use SIMION, a 3D ion tracing software in which we can trace particle beams of several energies and directions, passing through the instrument's units. We first reproduced ICA and IMA results, which turned out to be different from simple models for low energy (< 100 eV). We then change the mechanical structure of several units of the instrument and we quantify the new mass resolution achieved with each change. Our goal is to find the optimal instrument's structure, which will allow us to achieve a proper mass resolution to distinguish atomic nitrogen from atomic oxygen for the purposes of a future magnetospheric mission.

  7. Compact Cryogenic Source of Periodic Hydrogen and Argon Droplet Beams for Intense Laser-Plasma Generation

    CERN Document Server

    Fraga, R A Costa; Kühnel, M; Hochhaus, D C; Schottelius, A; Polz, J; Kaluza, M C; Neumayer, P; Grisenti, R E

    2011-01-01

    We present a cryogenic source of periodic streams of micrometer-sized hydrogen (H2) and argon (Ar) droplets as ideal mass-limited target systems for fundamental intense laser-driven plasma applications. The highly compact design combined with a high temporal and spatial droplet stability makes our injector ideally suited for experiments using state-of-the-art low-repetition rate high-power lasers, in which a precise synchronization between the laser pulses and the droplets is mandatory. We demonstrate this explicitly by irradiating Ar droplets with pulses from a Petawatt laser.

  8. Compact cryogenic source of periodic hydrogen and argon droplet beams for relativistic laser-plasma generation

    Energy Technology Data Exchange (ETDEWEB)

    Fraga, R. A. Costa; Kalinin, A.; Kuehnel, M.; Schottelius, A. [Institut fuer Kernphysik, J. W. Goethe-Universitaet, Max-von-Laue-Str. 1, 60438 Frankfurt am Main (Germany); Hochhaus, D. C.; Neumayer, P. [EMMI Extreme Matter Institute and Research Division, GSI Helmholtzzentrum fuer Schwerionenforschung, Planckstr. 1, 64291 Darmstadt (Germany); FIAS Frankfurt Institute for Advanced Studies, J. W. Goethe-Universitaet, Ruth-Moufang-Str. 1, 60438 Frankfurt am Main (Germany); Polz, J. [Institut fuer Optik und Quantenelektronik, Max-Wien-Platz 1, 07743 Jena (Germany); Kaluza, M. C. [Institut fuer Optik und Quantenelektronik, Max-Wien-Platz 1, 07743 Jena (Germany); Helmholtz-Institut Jena, Froebelstieg 3, 07743 Jena (Germany); Grisenti, R. E. [Institut fuer Kernphysik, J. W. Goethe-Universitaet, Max-von-Laue-Str. 1, 60438 Frankfurt am Main (Germany); GSI Helmholtzzentrum fuer Schwerionenforschung, Planckstr. 1, 64291 Darmstadt (Germany)

    2012-02-15

    We present a cryogenic source of periodic streams of micrometer-sized hydrogen and argon droplets as ideal mass-limited target systems for fundamental intense laser-driven plasma applications. The highly compact design combined with a high temporal and spatial droplet stability makes our injector ideally suited for experiments using state-of-the-art high-power lasers in which a precise synchronization between the laser pulses and the droplets is mandatory. We show this by irradiating argon droplets with multi-terawatt pulses.

  9. A tandem mirror plasma source for a hybrid plume plasma propulsion concept

    Science.gov (United States)

    Yang, T. F.; Miller, R. H.; Wenzel, K. W.; Krueger, W. A.; Chang, F. R.

    1985-01-01

    This paper describes a tandem mirror magnetic plasma confinement device to be considered as a hot plasma source for the hybrid plume rocket concept. The hot plasma from this device is injected into an exhaust duct, which will interact with an annular layer of hypersonic neutral gas. Such a device can be used to study the dynamics of the hybrid plume and to experimentally verify the numerical predictions obtained with computer codes. The basic system design is also geared toward being lightweight and compact, as well as having high power density (i.e., several kW/sq cm) at the exhaust. This feature is aimed toward the feasibility of 'space testing'. The plasma is heated by microwaves. A 50 percent heating efficiency can be obtained by using two half-circle antennas. The preliminary Monte Carlo modeling of test particles result reported here indicates that interaction does take place in the exhaust duct. Neutrals gain energy from the ion, which confirms the hybrid plume concept.

  10. The plasma leptin concentration is closely associated with the body fat mass in nondiabetic uremic patients

    DEFF Research Database (Denmark)

    Clausen, P; Nielsen, P K; Olgaard, K

    1999-01-01

    Plasma leptin is associated with the body mass index and, more precisely, with the body fat mass. Plasma leptin has been found to be elevated in uremic patients. This study aimed at investigating the plasma leptin concentration and associations between plasma leptin, body fat mass, and glomerular...... filtration rate in nondiabetic predialysis uremic patients and in nondiabetic patients on chronic hemodialysis. Plasma leptin, body fat mass, and creatinine clearance were measured in 22 predialysis uremic patients, 18 hemodialysis patients, and 24 healthy control subjects. The logarithmically transformed...... plasma leptin concentration was closely associated with the body fat mass in all groups (r = 0.93, r = 0.83, and r = 0.72, respectively; p

  11. Limit of detection in the presence of instrumental and non-instrumental errors: study of the possible sources of error and application to the analysis of 41 elements at trace levels by inductively coupled plasma-mass spectrometry technique

    Energy Technology Data Exchange (ETDEWEB)

    Badocco, Denis; Lavagnini, Irma; Mondin, Andrea; Tapparo, Andrea; Pastore, Paolo, E-mail: paolo.pastore@unipd.it

    2015-05-01

    In this paper the detection limit was estimated when signals were affected by two error contributions, namely instrumental errors and operational-non-instrumental errors. The detection limit was theoretically obtained following the hypothesis testing schema implemented with the calibration curve methodology. The experimental calibration design was based on J standards measured I times with non-instrumental errors affecting each standard systematically but randomly among the J levels. A two-component variance regression was performed to determine the calibration curve and to define the detection limit in these conditions. The detection limit values obtained from the calibration at trace levels of 41 elements by ICP-MS resulted larger than those obtainable from a one component variance regression. The role of the reagent impurities on the instrumental errors was ascertained and taken into account. Environmental pollution was studied as source of non-instrumental errors. The environmental pollution role was evaluated by Principal Component Analysis technique (PCA) applied to a series of nine calibrations performed in fourteen months. The influence of the seasonality of the environmental pollution on the detection limit was evidenced for many elements usually present in the urban air particulate. The obtained results clearly indicated the need of using the two-component variance regression approach for the calibration of all the elements usually present in the environment at significant concentration levels. - Highlights: • Limit of detection was obtained considering a two variance component regression. • Calibration data may be affected by instrumental and operational conditions errors. • Calibration model was applied to determine 41 elements at trace level by ICP-MS. • Non instrumental errors were evidenced by PCA analysis.

  12. Serum/plasma methylmercury determination by isotope dilution gas chromatography-inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Baxter, Douglas C; Faarinen, Mikko; Österlund, Heléne; Rodushkin, Ilia; Christensen, Morten

    2011-09-01

    A method for the determination of methylmercury in plasma and serum samples was developed. The method uses isotope dilution with (198)Hg-labeled methylmercury, extraction into dichloromethane, back-extraction into water, aqueous-phase ethylation, purge and trap collection, thermal desorption, separation by gas chromatography, and mercury isotope specific detection by inductively coupled plasma mass spectrometry. By spiking 2 mL sample with 1.2 ng tracer, measurements in a concentration interval of (0.007-2.9) μg L(-1) could be performed with uncertainty amplification factors levels of 0.14 μg L(-1), 0.35 μg L(-1) and 2.8 μg L(-1), with recoveries in the range 82-110%. Application of the method to 50 plasma/serum samples yielded a median (mean; range) concentration of methylmercury of 0.081 (0.091; methylmercury has been directly measured in this kind of specimen, and is therefore the first estimate of a reference range.

  13. Comprehensive Analysis of Low-Molecular-Weight Human Plasma Proteome Using Top-Down Mass Spectrometry.

    Science.gov (United States)

    Cheon, Dong Huey; Nam, Eun Ji; Park, Kyu Hyung; Woo, Se Joon; Lee, Hye Jin; Kim, Hee Cheol; Yang, Eun Gyeong; Lee, Cheolju; Lee, Ji Eun

    2016-01-01

    While human plasma serves as a great source for disease diagnosis, low-molecular-weight (LMW) proteome (mass spectrometry to analyze the LMW proteoforms present in four types of human plasma samples pooled from three healthy controls (HCs) without immunoaffinity depletion and with depletion of the top two, six, and seven high-abundance proteins. The LMW proteoforms were first fractionated based on molecular weight using gel-eluted liquid fraction entrapment electrophoresis (GELFrEE). Then, the GELFrEE fractions containing up to 30 kDa were subjected to nanocapillary-LC-MS/MS, and the high-resolution MS and MS/MS data were processed using ProSightPC 3.0. As a result, a total of 442 LMW proteins and cleaved products, including those with post-translational modifications and single amino acid variations, were identified. From additional comparative analysis of plasma samples without immunoaffinity depletion between HCs and colorectal cancer (CRC) patients via top-down approach, tens of LMW proteoforms, including platelet factor 4, were found to show >1.5-fold changes between the plasma samples of HCs and CRC patients, and six of the LMW proteins were verified by Western blot analysis.

  14. Compact tunable Compton x-ray source from laser-plasma accelerator and plasma mirror

    CERN Document Server

    Tsai, Hai-En; Shaw, Joseph; Li, Zhengyan; Arefiev, Alexey V; Zhang, Xi; Zgadzaj, Rafal; Henderson, Watson; Khudik, V; Shvets, G; Downer, M C

    2014-01-01

    We present results of the first tunable Compton backscattering (CBS) x-ray source that is based on the easily aligned combination of a laser-plasma accelerator (LPA) and a plasma mirror (PM). The LPA is driven in the blowout regime by 30 TW, 30 fs laser pulses, and produces high-quality, tunable, quasi-monoenergetic electron beams. A thin plastic film near the gas jet exit efficiently retro-reflects the LPA driving pulse with relativistic intensity into oncoming electrons to produce $2\\times10^{7}$ CBS x-ray photons per shot with 10-20 mrad angular divergence and 50 % (FWHM) energy spread without detectable bremsstrahlung background. The x-ray central energy is tuned from 75 KeV to 200 KeV by tuning the LPA e-beam central energy. Particle-in-cell simulations of the LPA, the drive pulse/PM interaction and CBS agree well with measurements.

  15. Laser desorption lamp ionization source for ion trap mass spectrometry.

    Science.gov (United States)

    Wu, Qinghao; Zare, Richard N

    2015-01-01

    A two-step laser desorption lamp ionization source coupled to an ion trap mass spectrometer (LDLI-ITMS) has been constructed and characterized. The pulsed infrared (IR) output of an Nd:YAG laser (1064 nm) is directed to a target inside a chamber evacuated to ~15 Pa causing desorption of molecules from the target's surface. The desorbed molecules are ionized by a vacuum ultraviolet (VUV) lamp (filled with xenon, major wavelength at 148 nm). The resulting ions are stored and detected in a three-dimensional quadrupole ion trap modified from a Finnigan Mat LCQ mass spectrometer operated at a pressure of ≥ 0.004 Pa. The limit of detection for desorbed coronene molecules is 1.5 pmol, which is about two orders of magnitude more sensitive than laser desorption laser ionization mass spectrometry using a fluorine excimer laser (157 nm) as the ionization source. The mass spectrum of four standard aromatic compounds (pyrene, coronene, rubrene and 1,4,8,11,15,18,22,25-octabutoxy-29H,31H-phthalocyanine (OPC)) shows that parent ions dominate. By increasing the infrared laser power, this instrument is capable of detecting inorganic compounds.

  16. Potential applications of a new microwave ECR (electron cyclotron resonance) multicusp plasma ion source

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, C.C.

    1990-01-01

    A new microwave electron cyclotron resonance (ECR) multicusp plasma ion source using two ECR plasma production regions and multicusp plasma confinement has been developed at Oak Ridge National Laboratory. This source has been operated to produce uniform and dense plasmas over large areas of 300 to 400 cm{sup 2}. The plasma source has been operated with continuous argon gas feed and pulsed microwave power. The discharge initiation phenomena and plasma properties have been investigated and studied as functions of discharge parameters. Together with the discharge characteristics observed, a hypothetical discharge mechanism for this plasma source is reported and discussed. Potential applications, including plasma and ion-beam processing for manufacturing advanced microelectronics and for space electric propulsion, are discussed. 7 refs., 6 figs.

  17. Potential applications of a new microwave ECR multicusp plasma ion source

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, C.C. (Fusion Energy Div., Oak Ridge National Lab., TN (USA))

    1991-05-01

    A new microwave electron cyclotron resonance (ECR) multicusp plasma ion source using two ECR plasma production regions and multicusp plasma confinement has been developed at Oak Ridge National Laboratory. This source has been operated to produce uniform and dense plasmas over large areas of 300-400 cm{sup 2}. The plasma source has been operated with continuous argon gas feed and pulsed microwave power. The discharge initiation phenomena and plasma properties have been investigated and studied as functions of discharge parameters. Together with the discharge characteristics observed, a hypothetical discharge mechanism for this plasma source is reported and discussed. Potential applications, including plasma and ion-beam processing for manufacturing advanced microelectronics and for space electric propulsion, are discussed. (orig.).

  18. Note: Triggering behavior of a vacuum arc plasma source.

    Science.gov (United States)

    Lan, C H; Long, J D; Zheng, L; Dong, P; Yang, Z; Li, J; Wang, T; He, J L

    2016-08-01

    Axial symmetry of discharge is very important for application of vacuum arc plasma. It is discovered that the triggering method is a significant factor that would influence the symmetry of arc discharge at the final stable stage. Using high-speed multiframe photography, the transition processes from cathode-trigger discharge to cathode-anode discharge were observed. It is shown that the performances of the two triggering methods investigated are quite different. Arc discharge triggered by independent electric source can be stabilized at the center of anode grid, but it is difficult to achieve such good symmetry through resistance triggering. It is also found that the triggering process is highly correlated to the behavior of emitted electrons.

  19. Note: Triggering behavior of a vacuum arc plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Lan, C. H., E-mail: lanchaohui@163.com; Long, J. D.; Zheng, L.; Dong, P.; Yang, Z.; Li, J.; Wang, T.; He, J. L. [Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900 (China)

    2016-08-15

    Axial symmetry of discharge is very important for application of vacuum arc plasma. It is discovered that the triggering method is a significant factor that would influence the symmetry of arc discharge at the final stable stage. Using high-speed multiframe photography, the transition processes from cathode-trigger discharge to cathode-anode discharge were observed. It is shown that the performances of the two triggering methods investigated are quite different. Arc discharge triggered by independent electric source can be stabilized at the center of anode grid, but it is difficult to achieve such good symmetry through resistance triggering. It is also found that the triggering process is highly correlated to the behavior of emitted electrons.

  20. Temperature of the Source Plasma in Gradual Solar Energetic Particle Events

    CERN Document Server

    Reames, Donald V

    2015-01-01

    Scattering, during interplanetary transport in large, "gradual" solar energetic-particle (SEP) events, can cause element abundance enhancements or suppressions that depend upon the mass-to-charge ratio A/Q of the ions as an increasing power law early in events and a decreasing power law of the residual ions later. Since the Q values for the ions depend upon the source plasma temperature T, best fits to the power-law dependence of enhancements vs. A/Q provide a fundamentally new method to determine the most probable value of T for these events. We find that fits to the times of increasing and decreasing powers give similar values of T, most commonly (69%) in the range of 0.8-1.6 MK, consistent with the acceleration of ambient coronal plasma by shock waves driven out from the Sun by coronal mass ejections (CMEs). However, 24% of the SEP events studied showed plasma of 2.5-3.2 MK, typical of that previously determined for the smaller impulsive SEP events; these particles may be reaccelerated preferentially by qu...

  1. MAGNETIC FIELD GRADIENT EFFECTS ON ION FLUX BEHAVIORS IN ECR PLASMA SOURCES

    Institute of Scientific and Technical Information of China (English)

    1998-01-01

    The available electron cyclotron resonance plasma source has been simulated in two-dimensional configuration space (z, r) and three-dimensional velocity space (Vz, Vr Vθ). The simulation is focused on the magnetic field gradient effects on ion flux behaviors in electron cyclotron resonance plasma sources. The simulation results show that, when the magnetic field gradients increase, electron temperature, plasma density, ionization rate, and ion flux in Zdirection would decrease, while ion energy and plasma potential would increase.

  2. Counter-facing plasma focus system as a repetitive and/or long-pulse high energy density plasma source

    Science.gov (United States)

    Aoyama, Yutaka; Nakajima, Mitsuo; Horioka, Kazuhiko

    2009-11-01

    A plasma focus system composed of a pair of counter-facing coaxial plasma guns is proposed as a long-pulse and/or repetitive high energy density plasma source. A proof-of-concept experiment demonstrated that with an assist of breakdown and outer electrode connections, current sheets evolved into a configuration for stable plasma confinement at the center of the electrodes. The current sheets could successively compress and confine the high energy density plasma every half period of the discharge current, enabling highly repetitive light emissions in extreme ultraviolet region with time durations in at least ten microseconds.

  3. A microwave plasma source for VUV atmospheric photochemistry

    Science.gov (United States)

    Tigrine, S.; Carrasco, N.; Vettier, L.; Cernogora, G.

    2016-10-01

    Microwave plasma discharges working at low pressure are nowadays a well-developed technique mainly used to provide radiation at different wavelengths. The aim of this work is to show that those discharges are an efficient windowless vacuum ultra-violet (VUV) photon source for planetary atmospheric photochemistry experiments. To do this, we use a surfatron-type discharge with a neon gas flow in the mbar pressure range coupled to a photochemical reactor. Working in the VUV range allows nitrogen-dominated atmospheres to be focused on (λ  <  100 nm). The experimental setup makes sure that no energy sources (electrons, metastable atoms) other than the VUV photons interact with the reactive medium. Neon has two resonance lines at 73.6 and 74.3 nm that behave differently depending on the pressure or power conditions. In parallel, the VUV photon flux emitted at 73.6 nm has been experimentally estimated in different pressure and power conditions, and varies in a large range between 2  ×  1013 ph s-1 cm-2 and 4  ×  1014 ph s-1 cm-2, which is comparable to a VUV synchrotron photon flux. Our first case study is the atmosphere of Titan and its N2-CH4 atmosphere. With this VUV source, the production of HCN and C2N2, two major Titan compounds, is detected, ensuring the suitability of the source for atmospheric photochemistry experiments.

  4. Modeling laser produced plasmas with smoothed particle hydrodynamics for next generation advanced light sources

    Science.gov (United States)

    Holladay, Robert; Griffith, Alec; Murillo, Michael S.

    2016-10-01

    A computational model has been developed to study the evolution of a plasma generated by next-generation advanced light sources such as SLAC's LCLS and LANL's proposed MaRIE. Smoothed Particle Hydrodynamics (SPH) is used to model the plasma evolution because of the ease with which it handles the open boundary conditions and large deformations associated with these experiments. Our work extends the basic SPH method by utilizing a two-fluid model of an electron-ion plasma that also incorporates time dependent ionization and recombination by allowing the SPH fluid particles to have an evolving mass based on the mean ionization state of the plasma. Additionally, inter-species heating, thermal conduction, and electric fields are also accounted for. The effects of various initial conditions and model parameters will be presented, with the goal of using this framework to develop a model that can be used in the design and interpretation of future experiments. This work was supported by the Los Alamos National Laboratory Computational Physics Workshop.

  5. Debris-free laser plasma sources for EUVL based on gas jets

    Energy Technology Data Exchange (ETDEWEB)

    Kubiak, G.D.; O`Connell, D.; Krenz, K.D.

    1996-03-01

    EUV sources for EUVL must not only be bright for throughput, they must also be debris-free to increase condenser longevity. Many schemes to achieve bright, clean sources for EUVL have been studied, including mass-limited targets, cryogenic targets, electric discharges, and electron-beam pumped vapor. Several of these sources show promise, with varying degrees of brightness, debris reduction, and system complexity. We have studied pulsed gas jets, which we find to be relatively simple, debris-free sources when used under appropriate conditions. Under transverse, 1.06 {mu}m irradiation of the jet at incident laser intensities in the range of 10{sup 11}-10{sup 12} Watts/cm{sup 2}, the conversion efficiency into 2{pi} steradians is in the range of 0.3-0.4%, or approximately half the value exhibited by solid Au or W targets under similar conditions. Source sizes in the range of 350 {mu}m x 400 {mu}m can be achieved, as shown in Fig. 2, depending sensitively on both laser and gas jet parameters. One issue that must be overcome in the use of gas jet targets is the requirement that the laser-irradiated plasma be located as far from the jet nozzle as possible to avoid debris generation while maintaining adequate EUV conversion. We will describe conditions under which these criteria are met. Measurements of the reflectance lifetimes of multilayer-coated mirrors placed near the plasma source under these conditions will also be presented. The potential for scaling such sources up to meet the requirements of a commercial EUVL system will be discussed.

  6. Uranium quantification in semen by inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Todorov, Todor I; Ejnik, John W; Guandalini, Gustavo; Xu, Hanna; Hoover, Dennis; Anderson, Larry; Squibb, Katherine; McDiarmid, Melissa A; Centeno, Jose A

    2013-01-01

    In this study we report uranium analysis for human semen samples. Uranium quantification was performed by inductively coupled plasma mass spectrometry. No additives, such as chymotrypsin or bovine serum albumin, were used for semen liquefaction, as they showed significant uranium content. For method validation we spiked 2g aliquots of pooled control semen at three different levels of uranium: low at 5 pg/g, medium at 50 pg/g, and high at 1000 pg/g. The detection limit was determined to be 0.8 pg/g uranium in human semen. The data reproduced within 1.4-7% RSD and spike recoveries were 97-100%. The uranium level of the unspiked, pooled control semen was 2.9 pg/g of semen (n=10). In addition six semen samples from a cohort of Veterans exposed to depleted uranium (DU) in the 1991 Gulf War were analyzed with no knowledge of their exposure history. Uranium levels in the Veterans' semen samples ranged from undetectable (<0.8 pg/g) to 3350 pg/g. This wide concentration range for uranium in semen is consistent with known differences in current DU body burdens in these individuals, some of whom have retained embedded DU fragments.

  7. Uranium quantification in semen by inductively coupled plasma mass spectrometry

    Science.gov (United States)

    Todorov, Todor; Ejnik, John W.; Guandalini, Gustavo S.; Xu, Hanna; Hoover, Dennis; Anderson, Larry W.; Squibb, Katherine; McDiarmid, Melissa A.; Centeno, Jose A.

    2013-01-01

    In this study we report uranium analysis for human semen samples. Uranium quantification was performed by inductively coupled plasma mass spectrometry. No additives, such as chymotrypsin or bovine serum albumin, were used for semen liquefaction, as they showed significant uranium content. For method validation we spiked 2 g aliquots of pooled control semen at three different levels of uranium: low at 5 pg/g, medium at 50 pg/g, and high at 1000 pg/g. The detection limit was determined to be 0.8 pg/g uranium in human semen. The data reproduced within 1.4–7% RSD and spike recoveries were 97–100%. The uranium level of the unspiked, pooled control semen was 2.9 pg/g of semen (n = 10). In addition six semen samples from a cohort of Veterans exposed to depleted uranium (DU) in the 1991 Gulf War were analyzed with no knowledge of their exposure history. Uranium levels in the Veterans’ semen samples ranged from undetectable (<0.8 pg/g) to 3350 pg/g. This wide concentration range for uranium in semen is consistent with known differences in current DU body burdens in these individuals, some of whom have retained embedded DU fragments.

  8. Inclined slot-excited annular electron cyclotron resonance plasma source for hyperthermal neutral beam generation.

    Science.gov (United States)

    You, H-J; Kim, D-W; Koo, M; Jang, S-O; Jung, Y-H; Hong, S-H; Lee, B-J

    2011-01-01

    An inclined slot-excited antenna (ISLAN) electron cyclotron resonance (ECR) plasma source is newly designed and constructed for higher flux hyperthermal neutral beam (HNB) generation. The developed ISLAN source is modified from vertical slot-excited antenna (VSLAN) source in two aspects: one is the use of inclined slots instead of vertical slots, and the other is a cusp magnetic field configuration rather than a toroidal configuration. Such modifications allow us to have more uniform arrangement of slots and magnets, then enabling plasma generation more uniform and thinner. Moreover, ECR plasma allows higher ionization rate, enabling plasma density higher even in submillitorr pressures, therefore decreasing the collision rate and∕or the reionization rate of the reflected atoms while passing through the plasma, and eventually getting higher flux of HNBs. In this paper, we report the design features and the plasma characteristics of the ISLAN source by doing plasma measurements and electromagnetic simulations. It was found that ISLAN source can be a high potential source for larger flux HNB generation; the source was found to give higher plasma densities and better uniformities than inductively coupled plasma source, particularly in low pressure ranges. Also, it is important that using ISLAN gives easier matching and better stability, i.e., ISLAN shows similar field patterns and good plasma symmetries irrespective of the variations of the mean diameter of the ring resonator and∕or the presence of a limiter or a reflector, and the operating pressures.

  9. Microchip atmospheric pressure chemical ionization source for mass spectrometry.

    Science.gov (United States)

    Ostman, Pekka; Marttila, Seppo J; Kotiaho, Tapio; Franssila, Sami; Kostiainen, Risto

    2004-11-15

    A novel microchip heated nebulizer for atmospheric pressure chemical ionization mass spectrometry is presented. Anisotropic wet etching is used to fabricate the flow channels, inlet, and nozzle on a silicon wafer. An integrated heater of aluminum is sputtered on a glass wafer. The two wafers are jointed by anodic bonding, creating a two-dimensional version of an APCI source with a sample channel in the middle and gas channels symmetrically on both sides. The ionization is initiated with an external corona-discharge needle positioned 2 mm in front of the microchip heated nebulizer. The microchip APCI source provides flow rates down to 50 nL/min, stable long-term analysis with chip lifetime of weeks, good quantitative repeatability (RSD 0.995) with linear dynamic rage of at least 4 orders of magnitude, and cost-efficient manufacturing. The limit of detection (LOD) for acridine measured with microchip APCI at flow rate of 6.2 muL/min was 5 nM, corresponding to a mass flow of 0.52 fmol/s. The LOD with commercial macro-APCI at a flow rate of 1 mL/min for acridine was the same, 5 nM, corresponding to a significantly worse mass flow sensitivity (83 fmol/s) than measured with microchip APCI. The advantages of microchip APCI makes it a very attractive new microfluidic detector.

  10. Spatially resolved optical-emission spectroscopy of a radio-frequency driven iodine plasma source

    Science.gov (United States)

    Dedrick, James; Doyle, Scott; Grondein, Pascaline; Aanesland, Ane

    2016-09-01

    Iodine is of interest for potential use as a propellant for spacecraft propulsion, and has become attractive as a replacement to xenon due to its similar mass and ionisation potential. Optical emission spectroscopy has been undertaken to characterise the emission from a low-pressure, radio-frequency driven inductively coupled plasma source operating in iodine with respect to axial distance across its transverse magnetic filter. The results are compared with axial profiles of the electron temperature and density for identical source conditions, and the spatial distribution of the emission intensity is observed to be closely correlated with the electron temperature. This work has been done within the LABEX Plas@Par project, and received financial state aid managed by the ``Agence Nationale de la Recherche'', as part of the ``Programme d'Investissements d'Avenir'' under the reference ANR-11-IDEX-0004-02.

  11. Ablation plasma transport using multicusp magnetic field for laser ion source

    Science.gov (United States)

    Takahashi, K.; Umezawa, M.; Uchino, T.; Ikegami, K.; Sasaki, T.; Kikuchi, T.; Harada, N.

    2016-05-01

    We propose a plasma guiding method using multicusp magnetic field to transport the ablation plasma keeping the density for developing laser ion sources. To investigate the effect of guiding using the magnetic field on the ablation plasma, we demonstrated the transport of the laser ablation plasma in the multicusp magnetic field. The magnetic field was formed with eight permanent magnets and arranged to limit the plasma expansion in the radial direction. We investigated the variation of the plasma ion current density and charge distribution during transport in the magnetic field. The results indicate that the plasma is confined in the radial direction during the transport in the multicusp magnetic field.

  12. Perspective: The physics, diagnostics, and applications of atmospheric pressure low temperature plasma sources used in plasma medicine

    Science.gov (United States)

    Laroussi, M.; Lu, X.; Keidar, M.

    2017-07-01

    Low temperature plasmas have been used in various plasma processing applications for several decades. But it is only in the last thirty years or so that sources generating such plasmas at atmospheric pressure in reliable and stable ways have become more prevalent. First, in the late 1980s, the dielectric barrier discharge was used to generate relatively large volume diffuse plasmas at atmospheric pressure. Then, in the early 2000s, plasma jets that can launch cold plasma plumes in ambient air were developed. Extensive experimental and modeling work was carried out on both methods and much of the physics governing such sources was elucidated. Starting in the mid-1990s, low temperature plasma discharges have been used as sources of chemically reactive species that can be transported to interact with biological media, cells, and tissues and induce impactful biological effects. However, many of the biochemical pathways whereby plasma affects cells remain not well understood. This situation is changing rather quickly because the field, known today as "plasma medicine," has experienced exponential growth in the last few years thanks to a global research community that engaged in fundamental and applied research involving the use of cold plasma for the inactivation of bacteria, dental applications, wound healing, and the destruction of cancer cells/tumors. In this perspective, the authors first review the physics as well as the diagnostics of the principal plasma sources used in plasma medicine. Then, brief descriptions of their biomedical applications are presented. To conclude, the authors' personal assessment of the present status and future outlook of the field is given.

  13. Quasi-steady carbon plasma source for neutral beam injector.

    Science.gov (United States)

    Koguchi, H; Sakakita, H; Kiyama, S; Shimada, T; Sato, Y; Hirano, Y

    2014-02-01

    Carbon plasma is successfully sustained during 1000 s without any carrier gas in the bucket type ionization chamber with cusp magnetic field. Every several seconds, seed plasmas having ∼3 ms duration time are injected into the ionization chamber by a shunting arch plasma gun. The weakly ionized carbon plasma ejected from the shunting arch is also ionized by 2.45 GHz microwave at the electron cyclotron resonance surface and the plasma can be sustained even in the interval of gun discharges. Control of the gun discharge interval allows to keep high pressure and to sustain the plasma for long duration.

  14. Physics-electrical hybrid model for real time impedance matching and remote plasma characterization in RF plasma sources

    Science.gov (United States)

    Sudhir, Dass; Bandyopadhyay, M.; Chakraborty, A.

    2016-02-01

    Plasma characterization and impedance matching are an integral part of any radio frequency (RF) based plasma source. In long pulse operation, particularly in high power operation where plasma load may vary due to different reasons (e.g. pressure and power), online tuning of impedance matching circuit and remote plasma density estimation are very useful. In some cases, due to remote interfaces, radio activation and, due to maintenance issues, power probes are not allowed to be incorporated in the ion source design for plasma characterization. Therefore, for characterization and impedance matching, more remote schemes are envisaged. Two such schemes by the same authors are suggested in these regards, which are based on air core transformer model of inductive coupled plasma (ICP) [M. Bandyopadhyay et al., Nucl. Fusion 55, 033017 (2015); D. Sudhir et al., Rev. Sci. Instrum. 85, 013510 (2014)]. However, the influence of the RF field interaction with the plasma to determine its impedance, a physics code HELIC [D. Arnush, Phys. Plasmas 7, 3042 (2000)] is coupled with the transformer model. This model can be useful for both types of RF sources, i.e., ICP and helicon sources.

  15. Physics-electrical hybrid model for real time impedance matching and remote plasma characterization in RF plasma sources

    Energy Technology Data Exchange (ETDEWEB)

    Sudhir, Dass, E-mail: dass.sudhir@iter-india.org; Bandyopadhyay, M.; Chakraborty, A. [ITER-India, Institute for Plasma Research, A-29 GIDC, Sec-25, Gandhinagar, 382016 Gujarat (India)

    2016-02-15

    Plasma characterization and impedance matching are an integral part of any radio frequency (RF) based plasma source. In long pulse operation, particularly in high power operation where plasma load may vary due to different reasons (e.g. pressure and power), online tuning of impedance matching circuit and remote plasma density estimation are very useful. In some cases, due to remote interfaces, radio activation and, due to maintenance issues, power probes are not allowed to be incorporated in the ion source design for plasma characterization. Therefore, for characterization and impedance matching, more remote schemes are envisaged. Two such schemes by the same authors are suggested in these regards, which are based on air core transformer model of inductive coupled plasma (ICP) [M. Bandyopadhyay et al., Nucl. Fusion 55, 033017 (2015); D. Sudhir et al., Rev. Sci. Instrum. 85, 013510 (2014)]. However, the influence of the RF field interaction with the plasma to determine its impedance, a physics code HELIC [D. Arnush, Phys. Plasmas 7, 3042 (2000)] is coupled with the transformer model. This model can be useful for both types of RF sources, i.e., ICP and helicon sources.

  16. Physics-electrical hybrid model for real time impedance matching and remote plasma characterization in RF plasma sources.

    Science.gov (United States)

    Sudhir, Dass; Bandyopadhyay, M; Chakraborty, A

    2016-02-01

    Plasma characterization and impedance matching are an integral part of any radio frequency (RF) based plasma source. In long pulse operation, particularly in high power operation where plasma load may vary due to different reasons (e.g. pressure and power), online tuning of impedance matching circuit and remote plasma density estimation are very useful. In some cases, due to remote interfaces, radio activation and, due to maintenance issues, power probes are not allowed to be incorporated in the ion source design for plasma characterization. Therefore, for characterization and impedance matching, more remote schemes are envisaged. Two such schemes by the same authors are suggested in these regards, which are based on air core transformer model of inductive coupled plasma (ICP) [M. Bandyopadhyay et al., Nucl. Fusion 55, 033017 (2015); D. Sudhir et al., Rev. Sci. Instrum. 85, 013510 (2014)]. However, the influence of the RF field interaction with the plasma to determine its impedance, a physics code HELIC [D. Arnush, Phys. Plasmas 7, 3042 (2000)] is coupled with the transformer model. This model can be useful for both types of RF sources, i.e., ICP and helicon sources.

  17. Ferroelectric plasma sources for NDCX-II and heavy ion drivers

    Energy Technology Data Exchange (ETDEWEB)

    Gilson, E.P., E-mail: egilson@pppl.gov [Princeton Plasma Physics Laboratory, Princeton University, P.O. Box 451, Princeton, New Jersey, 08543 (United States); Davidson, R.C.; Efthimion, P.C.; Kaganovich, I.D. [Princeton Plasma Physics Laboratory, Princeton University, P.O. Box 451, Princeton, New Jersey, 08543 (United States); Kwan, J.W.; Lidia, S.M.; Ni, P.A.; Roy, P.K.; Seidl, P.A.; Waldron, W.L. [Lawrence Berkeley National Laboratory, One Cyclotron Road, Berkeley, California, 94720 (United States); Barnard, J.J.; Friedman, A. [Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California, 94550 (United States)

    2014-01-01

    A barium titanate ferroelectric cylindrical plasma source has been developed, tested and delivered for the Neutralized Drift Compression Experiment NDCX-II at Lawrence Berkeley National Laboratory (LBNL). The plasma source design is based on the successful design of the NDCX-I plasma source. A 7 kV pulse applied across the 3.8 mm-thick ceramic cylinder wall produces a large polarization surface charge density that leads to breakdown and plasma formation. The plasma that fills the NDCX-II drift section upstream of the final-focusing solenoid has a plasma number density exceeding 10{sup 10} cm{sup −3} and an electron temperature of several eV. The operating principle of the ferroelectric plasma source are reviewed and a detailed description of the installation plans is presented. The criteria for plasma sources with larger number density will be given, and concepts will be presented for plasma sources for driver applications. Plasma sources for drivers will need to be highly reliable, and operate at several Hz for millions of shots.

  18. Ferroelectric plasma sources for NDCX-II and heavy ion drivers

    Science.gov (United States)

    Gilson, E. P.; Davidson, R. C.; Efthimion, P. C.; Kaganovich, I. D.; Kwan, J. W.; Lidia, S. M.; Ni, P. A.; Roy, P. K.; Seidl, P. A.; Waldron, W. L.; Barnard, J. J.; Friedman, A.

    2014-01-01

    A barium titanate ferroelectric cylindrical plasma source has been developed, tested and delivered for the Neutralized Drift Compression Experiment NDCX-II at Lawrence Berkeley National Laboratory (LBNL). The plasma source design is based on the successful design of the NDCX-I plasma source. A 7 kV pulse applied across the 3.8 mm-thick ceramic cylinder wall produces a large polarization surface charge density that leads to breakdown and plasma formation. The plasma that fills the NDCX-II drift section upstream of the final-focusing solenoid has a plasma number density exceeding 1010 cm-3 and an electron temperature of several eV. The operating principle of the ferroelectric plasma source are reviewed and a detailed description of the installation plans is presented. The criteria for plasma sources with larger number density will be given, and concepts will be presented for plasma sources for driver applications. Plasma sources for drivers will need to be highly reliable, and operate at several Hz for millions of shots.

  19. Ion source memory in {sup 36}Cl accelerator mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Pavetich, Stefan; Akhmadaliev, Shavkat; Merchel, Silke; Rugel, Georg [HZDR, Dresden (Germany); Arnold, Maurice; Aumaitre, Georges; Bourles, Didier; Martschini, Martin [ASTER, Aix-en-Provence (France); Buchriegler, Josef; Golser, Robin; Keddadouche, Karim; Steier, Peter [VERA, Vienna (Austria)

    2013-07-01

    Since the DREAMS (Dresden Accelerator Mass Spectrometry) facility went operational in 2011, constant effort was put into enabling routine measurements of long-lived radionuclides as {sup 10}Be, {sup 26}Al and {sup 41}Ca. For precise AMS-measurements of the volatile element Cl the key issue is the minimization of the long term memory effect. For this purpose one of the two original HVE sources was mechanically modified, allowing the usage of bigger cathodes with individual target apertures. Additionally a more open geometry was used to improve the vacuum level. To evaluate this improvement in comparison to other up-to-date ion sources, a small inter-laboratory comparison had been initiated. The long-term memory effect in the Cs sputter ion sources of the AMS facilities VERA, ASTER and DREAMS had been investigated by running samples of natural {sup 35}Cl/{sup 37}Cl-ratio and samples containing highly enriched {sup 35}Cl({sup 35}Cl/{sup 37}Cl > 500). Primary goals of the research are the time constants of the recovery from the contaminated sample ratio to the initial ratio of the sample and the level of the long-term memory effect in the sources.

  20. Determination of mycophenolic acid in human plasma by ultra performance liquid chromatography tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Vivek Upadhyay; Vikas Trivedi; Gaurang Shah; Manish Yadav; Pranav S. Shrivastav

    2014-01-01

    A simple, sensitive and high throughput ultra performance liquid chromatography tandem mass spectrometry method has been developed for the determination of mycophenolic acid in human plasma. The method involved simple protein precipitation of MPA along with its deuterated analog as an internal standard (IS) from 50 mL of human plasma. The chromatographic analysis was done on Acquity UPLC C18 (100mm*2.1mm,1.7mm) column under isocratic conditions using acetonitrile and 10 mM ammonium formate, pH 3.00 (75:25, v/v) as the mobile phase. A triple quadrupole mass spectrometer operating in the positive ionization mode was used for quantitation. In-source conversion of mycophenolic glucuronide metabolite to the parent drug was selectively controlled by suitable optimization of cone voltage, cone gas flow and desolvation temperature. The method was validated over a wide concentration range of 15–15000 ng/mL. The mean extraction recovery for the analyte and IS was 495%. Matrix effect expressed as matrix factors ranged from 0.97 to 1.02. The method was successfully applied to support a bioequivalence study of 500 mg mycophenolate mofetil tablet in 72 healthy subjects.

  1. Determination of mycophenolic acid in human plasma by ultra performance liquid chromatography tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Vivek Upadhyay

    2014-06-01

    Full Text Available A simple, sensitive and high throughput ultra performance liquid chromatography tandem mass spectrometry method has been developed for the determination of mycophenolic acid in human plasma. The method involved simple protein precipitation of MPA along with its deuterated analog as an internal standard (IS from 50 µL of human plasma. The chromatographic analysis was done on Acquity UPLC C18 (100 mm×2.1 mm, 1.7 µm column under isocratic conditions using acetonitrile and 10 mM ammonium formate, pH 3.00 (75:25, v/v as the mobile phase. A triple quadrupole mass spectrometer operating in the positive ionization mode was used for quantitation. In-source conversion of mycophenolic glucuronide metabolite to the parent drug was selectively controlled by suitable optimization of cone voltage, cone gas flow and desolvation temperature. The method was validated over a wide concentration range of 15–15000 ng/mL. The mean extraction recovery for the analyte and IS was >95%. Matrix effect expressed as matrix factors ranged from 0.97 to 1.02. The method was successfully applied to support a bioequivalence study of 500 mg mycophenolate mofetil tablet in 72 healthy subjects.

  2. The effects of added hydrogen on a helium atmospheric-pressure plasma jet ambient desorption/ionization source.

    Science.gov (United States)

    Wright, Jonathan P; Heywood, Matthew S; Thurston, Glen K; Farnsworth, Paul B

    2013-03-01

    We present mass spectrometric data demonstrating the effect that hydrogen has on a helium-based dielectric-barrier discharge (DBD) atmospheric-pressure plasma jet used as an ambient desorption/ionization (ADI) source. The addition of 0.9 % hydrogen to the helium support gas in a 35-W plasma jet increased signals for a range of test analytes, with enhancement factors of up to 68, without proportional increases in background levels. The changes in signal levels result from a combination of changes in the desorption kinetics from the surface and increased ion production in the gas phase. The enhancement in ADI-MS performance despite the quenching of key plasma species reported in earlier studies suggests that ionization with a H2/He plasma jet is the result of an alternate mechanism involving the direct generation of ionized hydrogen.

  3. Optimizing a microwave gas ion source for continuous-flow accelerator mass spectrometry.

    Science.gov (United States)

    von Reden, K F; Roberts, M L; Burton, J R; Beaupré, S R

    2012-02-01

    A 2.45 GHz microwave ion source coupled with a magnesium charge exchange canal (C × C) has been successfully adapted to a large acceptance radiocarbon accelerator mass spectrometry system at the National Ocean Sciences Accelerator Mass Spectrometry (AMS) Facility, Woods Hole Oceanographic Institution. CO(2) samples from various preparation sources are injected into the source through a glass capillary at 370 μl∕min. Routine system parameters are about 120-140 μA of negative (12)C current after the C × C, leading to about 400 (14)C counts per second for a modern sample and implying a system efficiency of 0.2%. While these parameters already allow us to perform high-quality AMS analyses on large samples, we are working on ways to improve the output of the ion source regarding emittance and efficiency. Modeling calculations suggest modifications in the extraction triode geometry, shape, and size of the plasma chamber could improve emittance and, hence, ion transport efficiency. Results of experimental tests of these modifications are presented.

  4. Analysis of plasma distribution near the extraction region in surface produced negative ion sources.

    Science.gov (United States)

    Fukano, A; Hatayama, A

    2014-02-01

    In study of a negative ion source, it is important to understand the plasma characteristics near the extraction region. A recent experiment in the NIFS-R&D ion source has suggested that a "double ion plasma layer" which is a region consisting of hydrogen positive and negative ions exists near the plasma grid (PG). Density distribution of plasma near the extraction region is studied analytically. It is shown that the density distribution depends on an amount of the surface produced negative ions and the double ion plasma layer is formed near the PG surface for the case of strong surface production.

  5. VUV Emission of Microwave Driven Argon Plasma Source

    Science.gov (United States)

    Henriques, Julio; Espinho, Susana; Felizardo, Edgar; Tatarova, Elena; Dias, Francisco; Ferreira, Carlos

    2013-09-01

    An experimental and kinetic modeling investigation of a low-pressure (0.1-1.2 mbar), surface wave (2.45 GHz) induced Ar plasma as a source vacuum ultraviolet (VUV) light is presented, using visible and VUV optical spectroscopy. The electron density and the relative VUV emission intensities of excited Ar atoms (at 104.8 nm and 106.6 nm) and ions (at 92.0 nm and 93.2 nm) were determined as a function of the microwave power and pressure. The experimental results were analyzed using a 2D self-consistent theoretical model based on a set of coupled equations including the electron Boltzmann equation, the rate balance equations for the most important electronic excited species and for charged particles, the gas thermal balance equation, and the wave electrodynamics. The principal collisional and radiative processes for neutral Ar(3p54s) and Ar(3p54p) and ionized Ar(3s3p6 2S1/2) levels are accounted for. Model predictions are in good agreement with the experimental measurements. This study was funded by the Foundation for Science and Technology, Portuguese Ministry of Education and Science, under the research contract PTDC/FIS/108411/2008.

  6. Multifluid MHD simulation of Saturn's magnetosphere: Dynamics of mass- and momentum-loading, and seasonal variation of the plasma sheet

    Science.gov (United States)

    Rajendar, A.; Paty, C. S.; Arridge, C. S.; Jackman, C. M.; Smith, H. T.

    2013-12-01

    Saturn's magnetosphere is driven externally, by the solar wind, and internally, by the planet's strong magnetic field, rapid rotation rate, and the addition of new plasma created from Saturn's neutral cloud. Externally, the alignment of the rotational and magnetic dipole axes, combined with Saturn's substantial inclination to its plane of orbit result in substantial curvature of the plasma sheet during solstice. Internally, new water group ions are produced in the inner regions of the magnetosphere from photoionization and electron-impact ionization of the water vapor and OH cloud sourced from Enceladus and other icy bodies in Saturn's planetary system. In addition to this, charge-exchange collisions between the relatively fast-moving water group ions and the slower neutrals results in a net loss of momentum from the plasma. In order to study these phenomena, we have made significant modifications to the Saturn multifluid model. This model has been previously used to investigate the external triggering of plasmoids and the interchange process using a fixed internal source rate. In order to improve the fidelity of the model, we have incorporated a physical source of mass- and momentum-loading by including an empirical representation of Saturn's neutral cloud and modifying the multifluid MHD equations to include mass- and momentum-loading terms. Collision cross-sections between ions, electrons, and neutrals are calculated as functions of closure velocity and energy at each grid point and time step, enabling us to simulate the spatially and temporally varying plasma-neutral interactions. In addition to this, by altering the angle of incidence of the solar wind relative to Saturn's rotational axis and applying a realistic latitudinally- and seasonally-varying ionospheric conductivity, we are also able to study seasonal effects on Saturn's magnetosphere. We use the updated multifluid simulation to investigate the dynamics of Saturn's magnetosphere, focusing specifically

  7. Plasma ion sources and ion beam technology inmicrofabrications

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Lili [Univ. of California, Berkeley, CA (United States)

    2007-01-01

    For over decades, focused ion beam (FIB) has been playing a very important role in microscale technology and research, among which, semiconductor microfabrication is one of its biggest application area. As the dimensions of IC devices are scaled down, it has shown the need for new ion beam tools and new approaches to the fabrication of small-scale devices. In the meanwhile, nanotechnology has also deeply involved in material science research and bioresearch in recent years. The conventional FIB systems which utilize liquid gallium ion sources to achieve nanometer scale resolution can no longer meet the various requirements raised from such a wide application area such as low contamination, high throughput and so on. The drive towards controlling materials properties at nanometer length scales relies on the availability of efficient tools. In this thesis, three novel ion beam tools have been developed and investigated as the alternatives for the conventional FIB systems in some particular applications. An integrated focused ion beam (FIB) and scanning electron microscope (SEM) system has been developed for direct doping or surface modification. This new instrument employs a mini-RF driven plasma source to generate focused ion beam with various ion species, a FEI two-lens electron (2LE) column for SEM imaging, and a five-axis manipulator system for sample positioning. An all-electrostatic two-lens column has been designed to focus the ion beam extracted from the source. Based on the Munro ion optics simulation, beam spot sizes as small as 100 nm can be achieved at beam energies between 5 to 35 keV if a 5 μm-diameter extraction aperture is used. Smaller beam spot sizes can be obtained with smaller apertures at sacrifice of some beam current. The FEI 2LE column, which utilizes Schottky emission, electrostatic focusing optics, and stacked-disk column construction, can provide high-resolution (as small as 20 nm) imaging capability, with fairly long working distance (25

  8. Source formulation for electron-impact ionization for fluid plasma simulations

    DEFF Research Database (Denmark)

    Müller, S.H.; Holland, C.; Tynan, G.R.;

    2009-01-01

    The derivation of the correct functional form of source terms in plasma fluid theory is revisited. The relation between the fluid source terms and atomic physics differential cross sections is established for particle-impact ionization. It is shown that the interface between atomic and plasma...

  9. Dependence of the source performance on plasma parameters at the BATMAN test facility

    Energy Technology Data Exchange (ETDEWEB)

    Wimmer, C.; Fantz, U. [Max-Planck-Institut für Plasmaphysik, Boltzmannstr. 2, 85748 Garching (Germany)

    2015-04-08

    The investigation of the dependence of the source performance (high j{sub H{sup −}}, low j{sub e}) for optimum Cs conditions on the plasma parameters at the BATMAN (Bavarian Test MAchine for Negative hydrogen ions) test facility is desirable in order to find key parameters for the operation of the source as well as to deepen the physical understanding. The most relevant source physics takes place in the extended boundary layer, which is the plasma layer with a thickness of several cm in front of the plasma grid: the production of H{sup −}, its transport through the plasma and its extraction, inevitably accompanied by the co-extraction of electrons. Hence, a link of the source performance with the plasma parameters in the extended boundary layer is expected. In order to characterize electron and negative hydrogen ion fluxes in the extended boundary layer, Cavity Ring-Down Spectroscopy and Langmuir probes have been applied for the measurement of the H{sup −} density and the determination of the plasma density, the plasma potential and the electron temperature, respectively. The plasma potential is of particular importance as it determines the sheath potential profile at the plasma grid: depending on the plasma grid bias relative to the plasma potential, a transition in the plasma sheath from an electron repelling to an electron attracting sheath takes place, influencing strongly the electron fraction of the bias current and thus the amount of co-extracted electrons. Dependencies of the source performance on the determined plasma parameters are presented for the comparison of two source pressures (0.6 Pa, 0.45 Pa) in hydrogen operation. The higher source pressure of 0.6 Pa is a standard point of operation at BATMAN with external magnets, whereas the lower pressure of 0.45 Pa is closer to the ITER requirements (p ≤ 0.3 Pa)

  10. Dependence of the source performance on plasma parameters at the BATMAN test facility

    Science.gov (United States)

    Wimmer, C.; Fantz, U.

    2015-04-01

    The investigation of the dependence of the source performance (high jH-, low je) for optimum Cs conditions on the plasma parameters at the BATMAN (Bavarian Test MAchine for Negative hydrogen ions) test facility is desirable in order to find key parameters for the operation of the source as well as to deepen the physical understanding. The most relevant source physics takes place in the extended boundary layer, which is the plasma layer with a thickness of several cm in front of the plasma grid: the production of H-, its transport through the plasma and its extraction, inevitably accompanied by the co-extraction of electrons. Hence, a link of the source performance with the plasma parameters in the extended boundary layer is expected. In order to characterize electron and negative hydrogen ion fluxes in the extended boundary layer, Cavity Ring-Down Spectroscopy and Langmuir probes have been applied for the measurement of the H- density and the determination of the plasma density, the plasma potential and the electron temperature, respectively. The plasma potential is of particular importance as it determines the sheath potential profile at the plasma grid: depending on the plasma grid bias relative to the plasma potential, a transition in the plasma sheath from an electron repelling to an electron attracting sheath takes place, influencing strongly the electron fraction of the bias current and thus the amount of co-extracted electrons. Dependencies of the source performance on the determined plasma parameters are presented for the comparison of two source pressures (0.6 Pa, 0.45 Pa) in hydrogen operation. The higher source pressure of 0.6 Pa is a standard point of operation at BATMAN with external magnets, whereas the lower pressure of 0.45 Pa is closer to the ITER requirements (p ≤ 0.3 Pa).

  11. Molecularly imprinted polymers as selective adsorbents for ambient plasma mass spectrometry.

    Science.gov (United States)

    Cegłowski, Michał; Smoluch, Marek; Reszke, Edward; Silberring, Jerzy; Schroeder, Grzegorz

    2017-05-01

    The application of molecularly imprinted polymers (MIPs) as molecular scavengers for ambient plasma ionization mass spectrometry has been reported for the first time. MIPs were synthesized using methacrylic acid as functional monomer; nicotine, propyphenazone, or methylparaben as templates; ethylene glycol dimethacrylate as a cross-linker; and 2,2'-azobisisobutyronitrile as polymerization initiator. To perform ambient plasma ionization experiments, a setup consisting of the heated crucible, a flowing atmospheric-pressure afterglow (FAPA) plasma ion source, and a quadrupole ion trap mass spectrometer has been used. The heated crucible with programmable temperature allows for desorption of the analytes from MIPs structure which results in their direct introduction into the ion stream. Limits of detection, linearity of the proposed analytical procedure, and selectivities have been determined for three analytes: nicotine, propyphenazone, and methylparaben. The analytes used were chosen from various classes of organic compounds to show the feasibility of the analytical procedure. The limits of detections (LODs) were 10 nM, 10, and 0.5 μM for nicotine, propyphenazone, and methylparaben, respectively. In comparison with the measurements performed for the non-imprinted polymers, the values of LODs were improved for at least one order of magnitude due to preconcentration of the sample and reduction of background noise, contributing to signal suppression. The described procedure has shown linearity in a broad range of concentrations. The overall time of single analysis is short and requires ca. 5 min. The developed technique was applied for the determination of nicotine, propyphenazone, and methylparaben in spiked real-life samples, with recovery of 94.6-98.4%. The proposed method is rapid, sensitive, and accurate which provides a new option for the detection of small organic compounds in various samples. Graphical abstract The experimental setup used for analysis.

  12. New high temperature plasmas and sample introduction systems for analytical atomic emission and mass spectrometry. Progress report, January 1, 1990--December 31, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Montaser, A.

    1992-09-01

    New high temperature plasmas and new sample introduction systems are explored for rapid elemental and isotopic analysis of gases, solutions, and solids using mass spectrometry and atomic emission spectrometry. Emphasis was placed on atmospheric pressure He inductively coupled plasmas (ICP) suitable for atomization, excitation, and ionization of elements; simulation and computer modeling of plasma sources with potential for use in spectrochemical analysis; spectroscopic imaging and diagnostic studies of high temperature plasmas, particularly He ICP discharges; and development of new, low-cost sample introduction systems, and examination of techniques for probing the aerosols over a wide range. Refs., 14 figs. (DLC)

  13. Plasma ignition schemes for the SNS radio-frequency driven H- source

    Energy Technology Data Exchange (ETDEWEB)

    Schenkel, T.; Staples, J.W.; Thomae, W.; Reijonen, J.; Gough, R.A.; Leung, K.N.; Keller, R.

    2001-09-06

    The H{sup -} ion source for the Spallation Neutron Source (SNS) is a cesiated, radio-frequency driven (2 MHz) multicusp volume source which operates at a duty cycle of 6% (1 ms pulses and 60 Hz). In pulsed RF driven plasma sources, ignition of the plasma affects the stability of source operation and the antenna lifetime. We are reporting on investigations of different ignition schemes, based on secondary electron generation in the plasma chamber by UV light, a hot filament, a low power RF plasma (cw, 13.56 MHz), as well as source operation solely with the high power (40 kW) 2 MHz RF. We find that the dual frequency, single antenna scheme is most attractive for the operating conditions of the SNS H{sup -} source.

  14. Color Developing Capacity of Plasma-treated Water as a Source of Nitrite for Meat Curing

    OpenAIRE

    2015-01-01

    The interaction of plasma with liquid generates nitrogen species including nitrite (NO− 2). Therefore, the color developing capacity of plasma-treated water (PTW) as a nitrite source for meat curing was investigated in this study. PTW, which is generated by surface dielectric barrier discharge in air, and the increase of plasma treatment time resulted in increase of nitrite concentration in PTW. The PTW used in this study contains 46 ppm nitrite after plasma treatment for 30 min. To evaluate ...

  15. Inductively Coupled Plasma: Fundamental Particle Investigations with Laser Ablation and Applications in Magnetic Sector Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Saetveit, Nathan Joe [Iowa State Univ., Ames, IA (United States)

    2008-01-01

    Particle size effects and elemental fractionation in laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) are investigated with nanosecond and femtosecond laser ablation, differential mobility analysis, and magnetic sector ICP-MS. Laser pulse width was found to have a significant influence on the LA particle size distribution and the elemental composition of the aerosol and thus fractionation. Emission from individual particles from solution nebulization, glass, and a pressed powder pellet are observed with high speed digital photography. The presence of intact particles in an ICP is shown to be a likely source of fractionation. A technique for the online detection of stimulated elemental release from neural tissue using magnetic sector ICP-MS is described. Detection limits of 1 μg L-1 or better were found for P, Mn, Fe, Cu, and Zn in a 60 μL injection in a physiological saline matrix.

  16. Mass and energy of erupting solar plasma observed with the X-Ray Telescope on Hinode

    CERN Document Server

    Lee, Jin-Yi; Reeves, Katharine K; Moon, Yong-Jae; Kim, Kap-Sung

    2014-01-01

    We investigate seven eruptive plasma observations by Hinode/XRT. Their corresponding EUV and/or white light CME features are visible in some events. Five events are observed in several passbands in X-rays, which allows the determination of the eruptive plasma temperature using a filter ratio method. We find that the isothermal temperatures vary from 1.6 to 10 MK. These temperatures are an average weighted toward higher temperature plasma. We determine the mass constraints of eruptive plasmas by assuming simplified geometrical structures of the plasma with isothermal plasma temperatures. This method provides an upper limit to the masses of the observed eruptive plasmas in X-ray passbands since any clumping causes the overestimation of the mass. For the other two events, we assume the temperatures are at the maximum temperature of the XRT temperature response function, which gives a lower limit of the masses. We find that the masses in XRT, ~3x10 13 - 5x10 14 g, are smaller in their upper limit than total masse...

  17. A narrow-band, variable energy ion source derived from a wire plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Gueroult, R; Elias, P Q; Packan, D [ONERA Palaiseau, 91761 Palaiseau (France); Rax, J M, E-mail: renaud.gueroult@polytechnique.edu [LPP, Ecole Polytechnique, 91128 Palaiseau Cedex (France)

    2011-08-15

    A low pressure wire-induced plasma source (WIPS) operated in its high-pressure mode ({approx}10{sup -2} mbar) exhibits a narrow ion energy distribution function peaked at an energy corresponding to the discharge voltage. In order to take advantage of this peculiar feature, we design an electrode geometry enabling the acceleration of ions extracted from a WIPS. Probing of the obtained ion plume by means of a retarding potential analyser (RPA) demonstrates the capability of such an ion source to generate narrow-band (full width at half maximum of about 20 eV), variable energy (1 to 5 keV) ion beams. Comparison with particle-in-cell simulations of the WIPS shows that the energy spread of these ion beams is actually about 10 eV, the slight broadening being mainly the effect of the limited planar RPA energy resolution. The ion beam spot size measured at 6 cm of the ion source exit is about 3 mm for a 10 {mu}A He{sup +} beam at 2 keV, with a divergence of about one degree. Operating the WIPS in argon and xenon leads to similar properties for Ar{sup +} and Xe{sup +} beams, and in principle other species could also be used.

  18. Advanced plasma flow simulations of cathodic-arc and ferroelectric plasma sources for neutralized drift compression experiments

    Directory of Open Access Journals (Sweden)

    Adam B. Sefkow

    2008-07-01

    Full Text Available Large-space-scale and long-time-scale plasma flow simulations are executed in order to study the spatial and temporal evolution of plasma parameters for two types of plasma sources used in the neutralized drift compression experiment (NDCX. The results help assess the charge neutralization conditions for ion beam compression experiments and can be employed in more sophisticated simulations, which previously neglected the dynamical evolution of the plasma. Three-dimensional simulations of a filtered cathodic-arc plasma source show the coupling efficiency of the plasma flow from the source to the drift region depends on geometrical factors. The nonuniform magnetic topology complicates the well-known general analytical considerations for evaluating guiding-center drifts, and particle-in-cell simulations provide a self-consistent evaluation of the physics in an otherwise challenging scenario. Plasma flow profiles of a ferroelectric plasma source demonstrate that the densities required for longitudinal compression experiments involving ion beams are provided over the drift length, and are in good agreement with measurements. Simulations involving azimuthally asymmetric plasma creation conditions show that symmetric profiles are nevertheless achieved at the time of peak on-axis plasma density. Also, the ferroelectric plasma expands upstream on the thermal expansion time scale, and therefore avoids the possibility of penetration into the acceleration gap and transport sections, where partial neutralization would increase the beam emittance. Future experiments on NDCX will investigate the transverse focusing of an axially compressing intense charge bunch to a sub-mm spot size with coincident focal planes using a strong final-focus solenoid. In order to fill a multi-tesla solenoid with the necessary high-density plasma for beam charge neutralization, the simulations predict that supersonically injected plasma from the low-field region will penetrate and

  19. Damping of electron center-of-mass oscillation in ultracold plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Wei-Ting; Witte, Craig; Roberts, Jacob L. [Department of Physics, Colorado State University, Fort Collins, Colorado 80523 (United States)

    2016-05-15

    Applying a short electric field pulse to an ultracold plasma induces an electron plasma oscillation. This manifests itself as an oscillation of the electron center of mass around the ion center of mass in the ultracold plasma. In general, the oscillation can damp due to either collisionless or collisional mechanisms, or a combination of the both. To investigate the nature of oscillation damping in ultracold plasmas, we developed a molecular dynamics model of the ultracold plasma electrons. Through this model, we found that depending on the neutrality of the ultracold plasma and the size of an applied DC electric field, there are some parameter ranges where the damping is primarily collisional and some primarily collisionless. We conducted experiments to compare the measured damping rate with theory predictions and found them to be in good agreement. Extension of our measurements to different parameter ranges should enable studies for strong-coupling influence on electron-ion collision rates.

  20. Cold plasma source for bacterial inactivation at atmospheric pressure

    DEFF Research Database (Denmark)

    Chen, Weifeng; Stamate, Eugen; Mejlholm, Ole

    plasma treatment conditions (e.g. power, frequency, time). Preliminary experiments were also performed to evaluate the eect of plasma treatment time on the reduction of the concentration of microorganisms (Lactobacillus sakei and Photobacterium phosphoreum) on inoculated slides of Long & Hammer agar...

  1. MASS AND ENERGY OF ERUPTING SOLAR PLASMA OBSERVED WITH THE X-RAY TELESCOPE ON HINODE

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin-Yi; Moon, Yong-Jae; Kim, Kap-Sung [Department of Astronomy and Space Science, Kyung Hee University, Yongin, Gyeonggi 446-701 (Korea, Republic of); Raymond, John C.; Reeves, Katharine K., E-mail: jlee@khu.ac.kr [Harvard-Smithsonian Center for Astrophysics, Cambridge, MA 02138 (United States)

    2015-01-10

    We investigate seven eruptive plasma observations by Hinode/XRT. Their corresponding EUV and/or white light coronal mass ejection features are visible in some events. Five events are observed in several passbands in X-rays, which allows for the determination of the eruptive plasma temperature using a filter ratio method. We find that the isothermal temperatures vary from 1.6 to 10 MK. These temperatures are an average weighted toward higher temperature plasma. We determine the mass constraints of eruptive plasmas by assuming simplified geometrical structures of the plasma with isothermal plasma temperatures. This method provides an upper limit to the masses of the observed eruptive plasmas in X-ray passbands since any clumping causes the overestimation of the mass. For the other two events, we assume the temperatures are at the maximum temperature of the X-ray Telescope (XRT) temperature response function, which gives a lower limit of the masses. We find that the masses in XRT, ∼3 × 10{sup 13}-5 × 10{sup 14} g, are smaller in their upper limit than the total masses obtained by LASCO, ∼1 × 10{sup 15} g. In addition, we estimate the radiative loss, thermal conduction, thermal, and kinetic energies of the eruptive plasma in X-rays. For four events, we find that the thermal conduction timescales are much shorter than the duration of eruption. This result implies that additional heating during the eruption may be required to explain the plasma observations in X-rays for the four events.

  2. Intermediate mass dilepton production during the chemical equilibration of quark gluon plasma

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The production of dileptons from the chemically equilibrating quark gluon plasma in the intermediate mass region has been studied. Comparing with the calculated results based on the thermodynamic equilibrium system of quark gluon plasma, it has been found that the quark phase of the chemically equilibrating system gives rise to an even larger enhancement of the dileptons production. Therefore, such an enhancement of dilepton production may signal the formation of quark gluon plasma.

  3. Cold plasma source for bacterial inactivation at atmospheric pressure

    DEFF Research Database (Denmark)

    Chen, Weifeng; Stamate, Eugen; Mejlholm, Ole

    A dielectric-barrier discharge system for cold plasma production was built for bacterial inactivation purpose. The eect of cold plasma treatment on sensory properties of seafood products was studied to establish how the sensory properties (e.g. appearance, texture) of seafood were aected by dierent....... The results show that the concentration of Lb. sakei on agar slides was reduced signicantly (P cold plasma for 120 seconds. Treatment of agar slides with cold plasma for 60 seconds was sucient to reduce the concentration of P. phosphoreum to below the detection limit......, corresponding to a reduction of > 4-5 log (cfu/g). Further studies are need on the eect of cold plasma treatments on sensory properties of cold-smoked salmon...

  4. An Electrothermal Plasma Source Developed for Simulation of Transient Heat Loads in Future Large Fusion Devices

    Science.gov (United States)

    Gebhart, Trey; Baylor, Larry; Winfrey, Leigh

    2016-10-01

    The realization of fusion energy requires materials that can withstand high heat and particle fluxes at the plasma material interface. In this work, an electrothermal (ET) plasma source has been designed as a possible transient heat flux source for a linear plasma material interaction device. An ET plasma source operates in the ablative arc regime, which is driven by a DC capacitive discharge. The current travels through the 4mm bore of a boron nitride liner and subsequently ablates and ionizes the liner material. This results in a high density plasma with a large unidirectional bulk flow out of the source exit. The pulse length for the ET source has been optimized using a pulse forming network to have a duration of 1ms at full-width half maximum. The peak currents and maximum source energies seen in this system are 2kA and 5kJ. The goal of this work is to show that the ET source produces electron densities and heat fluxes that are comparable to transient events in future large magnetic confinement fusion devices. Heat flux, plasma temperature, and plasma density were determined for each test shot using infrared imaging and optical spectroscopy techniques. This work will compare the ET source output (heat flux, temperature, and density) with and without an applied magnetic field. Research sponsored by the Laboratory Directed Research and Development Program of Oak Ridge National Laboratory, managed by UT-Battelle, LLC, for the U. S. Department of Energy.

  5. The minimization of non-equilibrium plasma source at high pressure

    Institute of Scientific and Technical Information of China (English)

    BAI MinDi; QIU XiuMei; LIU Dong; YANG Bo; ZHOU JianGang; XUE XiaoHong; GU JianLong

    2008-01-01

    The density of plasma produced by atmospheric non-equilibrium plasma source is the function of en-ergy dissipation rate in ionization electric field and gas particles momentum. The experiment shows that the plasma density highly rises with the increasing of energy dissipation rate and gas particles momentum. When the energy dissipation rate of activation field is 2.18 Wh/m3 and the average gas particles momentum is 109×10-22 g·m/s, the air throughput of plasma source whose volume is only 2.5 cm3 can be up to 12 m3/h and the density of plasma can be up to 1010 cm-3. The research can develop a method of producing minitype plasma source which is low energy consumption but high ion concert-tration used for chemical industry, environmental engineering and military.

  6. Electromagnetic, complex image model of a large area RF resonant antenna as inductive plasma source

    Science.gov (United States)

    Guittienne, Ph; Jacquier, R.; Howling, A. A.; Furno, I.

    2017-03-01

    A large area antenna generates a plasma by both inductive and capacitive coupling; it is an electromagnetically coupled plasma source. In this work, experiments on a large area planar RF antenna source are interpreted in terms of a multi-conductor transmission line coupled to the plasma. This electromagnetic treatment includes mutual inductive coupling using the complex image method, and capacitive matrix coupling between all elements of the resonant network and the plasma. The model reproduces antenna input impedance measurements, with and without plasma, on a 1.2× 1.2 m2 antenna used for large area plasma processing. Analytic expressions are given, and results are obtained by computation of the matrix solution. This method could be used to design planar inductive sources in general, by applying the termination impedances appropriate to each antenna type.

  7. An ultracompact X-ray source based on a laser-plasma undulator.

    Science.gov (United States)

    Andriyash, I A; Lehe, R; Lifschitz, A; Thaury, C; Rax, J-M; Krushelnick, K; Malka, V

    2014-08-22

    The capability of plasmas to sustain ultrahigh electric fields has attracted considerable interest over the last decades and has given rise to laser-plasma engineering. Today, plasmas are commonly used for accelerating and collimating relativistic electrons, or to manipulate intense laser pulses. Here we propose an ultracompact plasma undulator that combines plasma technology and nanoengineering. When coupled with a laser-plasma accelerator, this undulator constitutes a millimetre-sized synchrotron radiation source of X-rays. The undulator consists of an array of nanowires, which are ionized by the laser pulse exiting from the accelerator. The strong charge-separation field, arising around the wires, efficiently wiggles the laser-accelerated electrons. We demonstrate that this system can produce bright, collimated and tunable beams of photons with 10-100 keV energies. This concept opens a path towards a new generation of compact synchrotron sources based on nanostructured plasmas.

  8. Design of a high particle flux hydrogen helicon plasma source for used in plasma materials interaction studies

    Energy Technology Data Exchange (ETDEWEB)

    Goulding, Richard Howell [ORNL; Chen, Guangye [ORNL; Meitner, Steven J [ORNL; Baity Jr, F Wallace [ORNL; Caughman, John B [ORNL; Owen, Larry W [ORNL

    2009-01-01

    Existing linear plasma materials interaction (PMI) facilities all use plasma sources with internal electrodes. An rf-based helicon source is of interest because high plasma densities can be generated with no internal electrodes, allowing true steady state operation with minimal impurity generation. Work has begun at Oak Ridge National Laboratory (ORNL) to develop a large (15 cm) diameter helicon source producing hydrogen plasmas with parameters suitable for use in a linear PMI device: n(e) >= 10(19)m(-3), T(e) = 4-10 eV, particle flux Gamma(p) > 10(23) m(-3) s(-1), and magnetic field strength |B| up to I T in the source region. The device, whose design is based on a previous hydrogen helicon source operated at ORNL[1], will operate at rf frequencies in the range 10 - 26 MHz, and power levels up to similar to 100 kW. Limitations in cooling will prevent operation for pulses longer than several seconds, but a major goal will be the measurement of power deposition on device structures so that a later steady state version can be designed. The device design, the diagnostics to be used, and results of rf modeling of the device will be discussed. These include calculations of plasma loading, resulting currents and voltages in antenna structures and the matching network, power deposition profiles, and the effect of high |B| operation on power absorption.

  9. XID II: Statistical Cross-Association of ROSAT Bright Source Catalog X-ray Sources with 2MASS Point Source Catalog Near-Infrared Sources

    CERN Document Server

    Haakonsen, Christian Bernt; 10.1088/0067-0049/184/1/138

    2009-01-01

    The 18806 ROSAT All Sky Survey Bright Source Catalog (RASS/BSC) X-ray sources are quantitatively cross-associated with near-infrared (NIR) sources from the Two Micron All Sky Survey Point Source Catalog (2MASS/PSC). An association catalog is presented, listing the most likely counterpart for each RASS/BSC source, the probability Pid that the NIR source and X-ray source are uniquely associated, and the probability Pnoid that none of the 2MASS/PSC sources are associated with the X-ray source. The catalog includes 3853 high quality (Pid>0.98) X-ray--NIR matches, 2280 medium quality (0.98>Pid>0.9) matches, and 4153 low quality (0.9>Pid>0.5) matches. Of the high quality matches, 1418 are associations that are not listed in the SIMBAD database, and for which no high quality match with a USNO-A2 optical source was presented for the RASS/BSC source in previous work. The present work offers a significant number of new associations with RASS/BSC objects that will require optical/NIR spectroscopy for classification. For...

  10. Determination of selenoprotein P in human plasma by solid phase extraction and inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Bendahl, L.; Sidenius, U.; Gammelgaard, Bente

    2000-01-01

    measured by inductively coupled plasma mass spectrometry (ICP-MS) monitoring the Se-82 isotope. Linear response was observed in the concentration range 0.3-70.8 mu g/l selenium as selenoprotein P with a correlation coefficient of 0.9994. The precision expressed as relative standard deviation was better...

  11. A plasma source driven predator-prey like mechanism as a potential cause of spiraling intermittencies in linear plasma devices

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, D. [Research Center Jülich GmbH, Institute for Energy and Climate Research—Plasma Physics, D-52425 Jülich (Germany); Ohno, N. [Department of Energy Engineering and Science, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Tanaka, H. [National Institute for Fusion Science, Toki 509-5292 (Japan); Vela, L. [Physics Department, Universidad Carlos III de Madrid, Avda de la Universidad 30, 28911-Leganés, Madrid (Spain)

    2014-03-15

    Three-dimensional global drift fluid simulations are carried out to analyze coherent plasma structures appearing in the NAGDIS-II linear device (nagoya divertor plasma Simulator-II). The numerical simulations reproduce several features of the intermittent spiraling structures observed, for instance, statistical properties, rotation frequency, and the frequency of plasma expulsion. The detailed inspection of the three-dimensional plasma dynamics allows to identify the key mechanism behind the formation of these intermittent events. The resistive coupling between electron pressure and parallel electric field in the plasma source region gives rise to a quasilinear predator-prey like dynamics where the axisymmetric mode represents the prey and the spiraling structure with low azimuthal mode number represents the predator. This interpretation is confirmed by a reduced one-dimensional quasilinear model derived on the basis of the findings in the full three-dimensional simulations. The dominant dynamics reveals certain similarities to the classical Lotka-Volterra cycle.

  12. A plasma source driven predator-prey like mechanism as a potential cause of spiraling intermittencies in linear plasma devices

    Science.gov (United States)

    Reiser, D.; Ohno, N.; Tanaka, H.; Vela, L.

    2014-03-01

    Three-dimensional global drift fluid simulations are carried out to analyze coherent plasma structures appearing in the NAGDIS-II linear device (nagoya divertor plasma Simulator-II). The numerical simulations reproduce several features of the intermittent spiraling structures observed, for instance, statistical properties, rotation frequency, and the frequency of plasma expulsion. The detailed inspection of the three-dimensional plasma dynamics allows to identify the key mechanism behind the formation of these intermittent events. The resistive coupling between electron pressure and parallel electric field in the plasma source region gives rise to a quasilinear predator-prey like dynamics where the axisymmetric mode represents the prey and the spiraling structure with low azimuthal mode number represents the predator. This interpretation is confirmed by a reduced one-dimensional quasilinear model derived on the basis of the findings in the full three-dimensional simulations. The dominant dynamics reveals certain similarities to the classical Lotka-Volterra cycle.

  13. Thermodynamic Structure of Collision-Dominated Expanding Plasma: Heating of Interplanetary Coronal Mass Injections

    Science.gov (United States)

    Liu, Y.; Richardson, J. D.; Belcher, J. W.; Kasper, J. C.; Elliott, H. A.

    2006-01-01

    We investigate the thermodynamic structure of interplanetary coronal mass ejections (ICMEs) using combined surveys of the ejecta between 0.3 and 20 AU. ICMEs are shown to have a moderate expansion in the solar wind compared with theoretical predictions. The expansion seems to be governed by a polytrope with gamma approx. 1.3 in this distance range. We find that Coulomb collisions are important contributors to the ion-ion equilibration process in the ICME plasma. The alpha-proton differential speed quickly drops to below 10 km/s due to strong Coulomb collisions. However, the two species of particles are far from thermal equilibrium with a temperature ratio T(sub alpha/T(sub p) = 4-6, suggestive of a preferential heating of alpha particles. The plasma heating rate as a function of heliocentric &stance required for the temperature profile is deduced by taking into account the expansion and energy transfer between protons and alphas via Coulomb collisions. The turbulence dissipation rate is also inferred from the inertial range power spectrum of magnetic fluctuations within ICMEs. Comparison of the turbulence dissipation rate with the required heating rate shows that turbulence dissipation seems sufficient to explain the ICME heating. Sources powering the turbulence are also investigated by examining the instabilities induced by temperature anisotropies and energy deposition by pickup ions.

  14. PROMETHEUS-A: A helicon plasma source for future wakefield accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Buttenschoen, Birger; Fahrenkamp, Nils; Grulke, Olaf [Max Planck Institute for Plasma Physics, Wendelsteinstr. 1, 17491 Greifswald (Germany)

    2015-05-01

    High density plasma sources are of interest for a wide range of applications like plasma-wall interaction studies, plasma thrusters for space propulsion, or future plasma wakefield particle accelerators. In this contribution, we present a high power helicon cell designed for the world's first proton-beam driven plasma wakefield accelerator experiment AWAKE. Using a modular concept with four antennas distributed along a one meter long, five centimeter diameter prototype module providing up to 35 kW of rf power to the plasma, accelerator relevant densities of 6 . 10{sup 20} m{sup -3} are transiently achieved and exceeded. These high density plasmas are characterized for the use with wakefield accelerators, considering density evolution and its reproducibility, plasma profiles and neutral gas inventory.

  15. Plasma ignition and steady state simulations of the Linac4 H$^{-}$ ion source

    CERN Document Server

    Mattei, S; Yasumoto, M; Hatayama, A; Lettry, J; Grudiev, A

    2014-01-01

    The RF heating of the plasma in the Linac4 H- ion source has been simulated using an Particle-in-Cell Monte Carlo Collision method (PIC-MCC). This model is applied to investigate the plasma formation starting from an initial low electron density of 1012 m-3 and its stabilization at 1018 m-3. The plasma discharge at low electron density is driven by the capacitive coupling with the electric field generated by the antenna, and as the electron density increases the capacitive electric field is shielded by the plasma and induction drives the plasma heating process. Plasma properties such as e-/ion densities and energies, sheath formation and shielding effect are presented and provide insight to the plasma properties of the hydrogen plasma.

  16. QSARs for Plasma Protein Binding: Source Data and Predictions

    Data.gov (United States)

    U.S. Environmental Protection Agency — The dataset has all of the information used to create and evaluate 3 independent QSAR models for the fraction of a chemical unbound by plasma protein (Fub) for...

  17. Plasma properties of a new-type surface wave-sustained plasma source under the conditions of depositing DLC films

    Science.gov (United States)

    Xu, Junqi; Kousaka, Hiroyuki; Umehara, Noritsugu; Diao, Dongfeng

    2006-01-01

    Surface wave-sustained plasma (SWP) is one of the low-pressure, high- density plasma. Applying this technique, diamond-like carbon (DLC) films with excellent characteristics can be prepared by physical vapor deposition (PVD) method. However, the films' application is restricted in some degree, because it is difficult to control the film properties. In this paper, SWP was excited along a conductive rod at a frequency of 2.45 GHz without magnetic fields around the chamber wall. The fundamental theories of plasma diagnostic were presented and plasma properties were studied with a Langmuir probe under the conditions of depositing DLC films by PVD method with a graphite target. Plasma density, electron temperature, plasma potential and target current were measured at difference technique parameters such as gas pressure, microwave power, and so on. As a result, it was proved that plasma properties are greatly affected by microwave power, target voltage and argon gas pressure in chamber. The gas mass flow rate had almost no effect on plasma characters. At the same time, the results indicated that electron density is up to 10 11-10 12cm -3 even at the low pressure of 1 Pa.

  18. PLASMOSE - antimicrobial effects of modular atmospheric plasma sources

    OpenAIRE

    Ehlbeck, J; Van Brandenburg, R; von Woedtke, T; Krohmann, U; Stieber, M.; Weltmann, KD

    2008-01-01

    The technological potential of non-thermal plasmas for the antimicrobial treatment of heat sensitive materials is well known and has been documented in a great number of research activities, but the realisation of industrial plasma-based decontamination processes remains a great challenge. One of the reasons for this situation is the fact that an antimicrobial treatment process needs to consider all properties of the product to be treated as well as the requirements of the complete procedure,...

  19. Advanced Laser and RF Plasma Sources and Diagnostics

    Science.gov (United States)

    2007-06-13

    jacks, fibers, collimators, and breadboards $19,832.71 Interferometry Gunn diode and I-Q mixer $6,775.00 RF Components and Automation High...temperature diagnostics for both our laser window and radiofrequency air plasmas. We have also acquired a tunable 668 nm diode laser, optical filters...diagnostics for both our laser window and radiofrequency air plasmas. We have also acquired a tunable 668 nm diode laser, optical filters, splitters

  20. PIC/MCC simulation for magnetized capacitively coupled plasmas driven by combined dc/rf sources

    Science.gov (United States)

    Yang, Shali; Zhang, Ya; Jiang, Wei; Wang, Hongyu; Wang, Shuai

    2016-09-01

    Hybrid dc/rf capacitively coupled plasma (CCP) sources have been popular in substrate etching due to their simplicity in the device structure and better plasma property. In this work, the characteristics of magnetized capacitively coupled plasmas driven by combined dc/rf sources are described by a one-dimensional Particle-in-cell/Monte Carlo collision (PIC/MCC) model. The simulation is using a rf source of 13.56MHz in argon and at a low pressure of 50mTorr. The effects of dc voltage and magnetic field on the plasmas are examined for 200-400V and 0-200Gs. It is found that, to some extent, dc voltage will increase the plasma density, but plasma density drops with increasing dc voltage. The magnetic field will enhance the plasma density significantly, due to the magnetic field will increase the electron life time and decrease the loss to the electrodes. In the bulk plasma, electron temperature is increased with the magnetic field but decreased with the dc voltage. The electron temperature in sheath is higher than in bulk plasma, due to stochastic heating in sheath is greater than Ohmic heating in bulk plasma under low gas pressure. National Natural Science Foundation of China (11405067, 11105057, 11305032, 11275039).

  1. A novel ion source for the calibration of an MRTOF Mass Spectrograph to be used in superheavy elements mass measurements

    CERN Document Server

    Naimi, S; Ito, Y; Mita, H; Okada, K; Ozawa, A; Schury, P; Sonoda, T; Takamine, A; Wada, M; Wollnik, H

    2012-01-01

    A novel ion source based on electrospray ionization and radiofrequency carpet technique has been built. This ion source is designed to deliver relatively heavy molecules for the calibration of a multi reflection time-of-flight mass spectrograph (MRTOF-MS) that will be used for direct mass measurements of superheavy elements. The operation of the ion source as well as the analysis by the MRTOF-MS with heavy molecular ions is described.

  2. Continuous plasma outflows from the edge of a solar active region as a possible source of solar wind.

    Science.gov (United States)

    Sakao, Taro; Kano, Ryouhei; Narukage, Noriyuki; Kotoku, Jun'ichi; Bando, Takamasa; Deluca, Edward E; Lundquist, Loraine L; Tsuneta, Saku; Harra, Louise K; Katsukawa, Yukio; Kubo, Masahito; Hara, Hirohisa; Matsuzaki, Keiichi; Shimojo, Masumi; Bookbinder, Jay A; Golub, Leon; Korreck, Kelly E; Su, Yingna; Shibasaki, Kiyoto; Shimizu, Toshifumi; Nakatani, Ichiro

    2007-12-07

    The Sun continuously expels a huge amount of ionized material into interplanetary space as the solar wind. Despite its influence on the heliospheric environment, the origin of the solar wind has yet to be well identified. In this paper, we report Hinode X-ray Telescope observations of a solar active region. At the edge of the active region, located adjacent to a coronal hole, a pattern of continuous outflow of soft-x-ray-emitting plasmas was identified emanating along apparently open magnetic field lines and into the upper corona. Estimates of temperature and density for the outflowing plasmas suggest a mass loss rate that amounts to approximately 1/4 of the total mass loss rate of the solar wind. These outflows may be indicative of one of the solar wind sources at the Sun.

  3. Source characterization of PM10 and PM2.5 mass using a chemical mass balance model at urban roadside.

    Science.gov (United States)

    Srimuruganandam, B; Shiva Nagendra, S M

    2012-09-01

    The 24-h average ambient particulate matter (PM(10) and PM(2.5)) concentrations are sampled concurrently during November 2008-April 2009 at a busy roadside in Chennai City, India. The elemental (Ag, Al, As, B, Ba, Be, Bi, Ca, Cd, Co, Cr, Cu, Fe, Ga, K, Li, Mg, Mn, Mo, Na, Ni, Pb, Rb, Se, Sr, Te, Tl, V and Zn) and ionic (Na(+), NH(4)(+), K(+), Ca(2+), Mg(2+), F(-), Cl(-), NO(2)(-), NO(3)(-) and SO(4)(2-)) composition of PM(10) and PM(2.5) are determined using an inductively coupled plasma-optical emission spectrometer (ICP-OES) and an ion chromatograph (IC), respectively. The emission inventory at the study area is also carried out to identify the likely PM emission sources. The U.S. EPA's-CMB (chemical mass balance) version 8.2 is applied to identify the source contribution of ambient PM(10) and PM(2.5) concentrations at the study area. Results indicated that diesel exhausts (43-52% in PM(10) and 44-65% in PM(2.5)) and gasoline exhausts (6-16% in PM(10) and 3-8% in PM(2.5)) are found to be the major source contributors at the study site followed by the paved road dusts (PM(10)=PM(2.5)=0.-2.3%), brake lining dusts (0.1% in PM(10) and 0.2% in PM(2.5)), brake pad wear dusts (0.1% in PM(10) and 0.01% in PM(2.5)), marine aerosols (PM(10)=PM(2.5)=0.1%) and cooking (~0.8% in PM(10) and ~1.5% in PM(2.5)). Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Washer-Gun Plasma Source for Magnetic Reconnection Experiments on VTF

    Science.gov (United States)

    Vrublevskis, A.; Egedal, J.; Fox, W.; Katz, N.; Le, A.; Porkolab, M.

    2009-11-01

    We present a recently built electrostatic washer-gun plasma source for the Versatile Toroidal Facility (VTF). The source produces plasmas with estimated densities of ˜10^19 m^- 3 and electron temperatures of ˜5-20 eV. The present plasma source for VTF is microwave-induced electron cyclotron resonant breakdown and requires a strong toroidal magnetic field, which acts as a guide field in reconnection experiments. The gun will allow reconnection experiments with no guide field. The source is based on the design developed by Sterling Scientific [1, 2]. To operate, gas is injected into a channel formed by a stack of alternating molybdenum and boron nitride washers with a molybdenum electrode washer at each end. A capacitor bank is discharged through these electrodes and the gas. The resulting plasma escapes the channel into the main chamber of the experiment. If available, we will present data on argon plasma produced by the gun inside the VTF. [1ex] [1] G. Fiksel, et al., Plasma Sources Sci. Technol., 5, 78 (1996)[0ex] [2] D. Hartog et al., Plasma Sources Sci. Technol., 6, 492 (1997)

  5. Droplet-free high-density metal ion source for plasma immersion ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Keiji [Department of Electrical Engineering, College of Engineering, Chubu University, 1200 Matsumoto, Kasugai, Aichi 487-8501 (Japan)]. E-mail: nakamura@solan.chubu.ac.jp; Yoshinaga, Hiroaki [Department of Electrical Engineering, Doshisha University, 1-3 Tatara Miyakodani, Kyotanabe, Kyoto 610-0321 (Japan); Yukimura, Ken [Department of Electrical Engineering, Doshisha University, 1-3 Tatara Miyakodani, Kyotanabe, Kyoto 610-0321 (Japan)

    2006-01-15

    This paper reports on plasma parameters and ion composition of droplet-free Zr ion source for plasma immersion ion implantation and deposition (PIII and D). Zirconium (Zr) ions were obtained by ionizing sputtered Zr atoms in inductively-coupled argon discharge. The characteristics of plasma density, plasma potential and electron temperature were typical ones of such a inductive discharge, and the plasma parameters were not significantly influenced by mixing the sputtered Zr atoms into the plasma. Actually, the main ionic component was still Ar{sup +} ions, and the ion density ratio of [Zr{sup +}]/[Ar{sup +}] was as low as {approx}8%. Increase in sputtering rate of the Zr source will be necessary to improve the ion density ratio.

  6. Optimum plasma grid bias for a negative hydrogen ion source operation with Cs

    Energy Technology Data Exchange (ETDEWEB)

    Bacal, Marthe, E-mail: marthe.bacal@lpp.polytechnique.fr [UPMC, LPP, Ecole Polytechnique, UMR CNRS 7648, Palaiseau (France); Sasao, Mamiko [R& D Promotion Organization, Doshisha University, Kamigyoku, Kyoto 602-8580 (Japan); Wada, Motoi [School of Science and Engineering, Doshisha University, Kyotonabe, Kyoto 610-0321 (Japan); McAdams, Roy [CCFE, Culham Science Center, Abingdon, Oxfordshire 0X14 3DB (United Kingdom)

    2016-02-15

    The functions of a biased plasma grid of a negative hydrogen (H{sup −}) ion source for both pure volume and Cs seeded operations are reexamined. Proper control of the plasma grid bias in pure volume sources yields: enhancement of the extracted negative ion current, reduction of the co-extracted electron current, flattening of the spatial distribution of plasma potential across the filter magnetic field, change in recycling from hydrogen atomic/molecular ions to atomic/molecular neutrals, and enhanced concentration of H{sup −} ions near the plasma grid. These functions are maintained in the sources seeded with Cs with additional direct emission of negative ions under positive ion and neutral hydrogen bombardment onto the plasma electrode.

  7. Combustion flame-plasma hybrid reactor systems, and chemical reactant sources

    Science.gov (United States)

    Kong, Peter C

    2013-11-26

    Combustion flame-plasma hybrid reactor systems, chemical reactant sources, and related methods are disclosed. In one embodiment, a combustion flame-plasma hybrid reactor system comprising a reaction chamber, a combustion torch positioned to direct a flame into the reaction chamber, and one or more reactant feed assemblies configured to electrically energize at least one electrically conductive solid reactant structure to form a plasma and feed each electrically conductive solid reactant structure into the plasma to form at least one product is disclosed. In an additional embodiment, a chemical reactant source for a combustion flame-plasma hybrid reactor comprising an elongated electrically conductive reactant structure consisting essentially of at least one chemical reactant is disclosed. In further embodiments, methods of forming a chemical reactant source and methods of chemically converting at least one reactant into at least one product are disclosed.

  8. Hundred joules plasma focus device as a potential pulsed source for in vitro cancer cell irradiation

    Science.gov (United States)

    Jain, J.; Moreno, J.; Andaur, R.; Armisen, R.; Morales, D.; Marcelain, K.; Avaria, G.; Bora, B.; Davis, S.; Pavez, C.; Soto, L.

    2017-08-01

    Plasma focus devices may arise as useful source to perform experiments aimed to study the effects of pulsed radiation on human cells in vitro. In the present work, a table top hundred joules plasma focus device, namely "PF-400J", was adapted to irradiate colorectal cancer cell line, DLD-1. For pulsed x-rays, the doses (energy absorbed per unit mass, measured in Gy) were measured using thermoluminescence detectors (TLD-100 dosimeters). The neutron fluence and the average energy were used to estimate the pulsed neutron doses. Fifty pulses of x-rays (0.12 Gy) and fifty pulses of neutrons (3.5 μGy) were used to irradiate the cancer cells. Irradiation-induced DNA damage and cell death were assessed at different time points after irradiation. Cell death was observed using pulsed neutron irradiation, at ultralow doses. Our results indicate that the PF-400J can be used for in vitro assessment of the effect of pulsed radiation in cancer cell research.

  9. Shaping the electron beams with submicrosecond pulse duration in sources and electron accelerators with plasma emitters

    CERN Document Server

    Gushenets, V I

    2001-01-01

    One studies the techniques in use to shape submicrosecond electron beams and the physical processes associated with extraction of electrons from plasma in plasma emitters. Plasma emitter base sources and accelerators enable to generate pulse beams with currents varying from tens of amperes up to 10 sup 3 A, with current densities up to several amperes per a square centimeter, with pulse duration constituting hundreds of nanoseconds and with high frequencies of repetition

  10. Characterization of an atmospheric pressure air plasma source for polymer surface modification

    Science.gov (United States)

    Yang, Shujun; Tang, Jiansheng

    2013-10-01

    An atmospheric pressure air plasma source was generated through dielectric barrier discharge (DBD). It was used to modify polyethyleneterephthalate (PET) surfaces with very high throughput. An equivalent circuit model was used to calculate the peak average electron density. The emission spectrum from the plasma was taken and the main peaks in the spectrum were identified. The ozone density in the down plasma region was estimated by Absorption Spectroscopy. NSF and ARC-ODU

  11. Determination of stimulants using gas chromatography/high-resolution time-of-flight mass spectrometry and a soft ionization source.

    Science.gov (United States)

    Lopez-Avila, Viorica; Cooley, James; Urdahl, Randall; Thevis, Mario

    2012-12-15

    The aim of this study was to investigate the mass spectral fragmentation of a small set of stimulants in a high-resolution time-of-flight mass spectrometer equipped with a soft ionization source using vacuum ultraviolet (VUV) photons emitted from different plasma gases. It was postulated that the use of a plasma gas such as Xe, which emits photons at a lower energy than Kr or Ar, would lead to softer ionization of the test compounds, and thus to less fragmentation. A set of nine stimulants: cocaine, codeine, nicotine, methadone, phenmetrazine, pentylenetetrazole, niketamide, fencamfamine, and caffeine, was analyzed by gas chromatography/time-of-flight mass spectrometry (GC/TOFMS) in positive ion mode with this soft ionization source, using either Xe, Kr, or Ar as plasma gases. Working solutions of the test compounds at 0.1 to 100 ng/μL were used to establish instrument sensitivity and linearity. All test compounds, except methadone and pentylenetetrazole, exhibited strong molecular ions and no fragmentation with Xe-microplasma photoionization (MPPI). Methadone exhibited significant fragmentation not only with Xe, but also with Kr and Ar, and pentylenetetrazole could not be ionized with Xe, probably because its ionization energy is above 8.44 eV. The Kr- and Ar-MPPI mass spectra of the test compounds showed that the relative intensity of the molecular ion decreased as the photon energy increased. When coupled to a TOF mass spectrometer this soft ionization source has demonstrated signal-to-noise (S/N) ratios from 7 to 730 at 100 pg per injection (depending on the compound), and a dynamic range of three orders of magnitude (100 pg to 100 ng) for some of the test compounds. Copyright © 2012 John Wiley & Sons, Ltd.

  12. Epitaxial aluminum nitride tunnel barriers grown by nitridation with a plasma source

    NARCIS (Netherlands)

    Zijlstra, T.; Lodewijk, C.F.J.; Vercruyssen, N.; Tichelaar, F.D.; Loudkov, D.N.; Klapwijk, T.M.

    2007-01-01

    High critical current-density (10 to 420 kA/cm2) superconductor-insulator-superconductor tunnel junctions with aluminum nitride barriers have been realized using a remote nitrogen plasma from an inductively coupled plasma source operated in a pressure range of 10−3–10−1 mbar. We find a much better r

  13. Plasma diagnostics approach to welding heat source/molten pool interaction

    Energy Technology Data Exchange (ETDEWEB)

    Key, J.F.; McIlwain, M.E.; Isaacson, L.

    1980-01-01

    Plasma diagnostic techniques show that weld fusion zone profile and loss of metal vapors from the molten pool are strongly dependent on both the intensity and distribution of the heat source. These plasma properties, are functions of cathode vertex angle and thermal conductivity of the shielding gas, especially near the anode.

  14. Ambient desorption/ionization mass spectrometry using a liquid sampling-atmospheric glow discharge (LS-APGD) ionization source.

    Science.gov (United States)

    Marcus, R Kenneth; Burdette, Carolyn Q; Manard, Benjamin T; Zhang, Lynn X

    2013-10-01

    A novel approach to ambient desorption/ionization mass spectrometry (ADI-MS) is described, based on a recently developed liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source. The device is essentially unmodified relative to its implementation in elemental mass spectrometry, where the operational space is characterized by low operation power (LS-APGD source is mounted onto the source interface of a Thermo Finnigan LCQ Advantage Max quadrupole ion trap mass spectrometer without modifications to the instrument faceplate or ion optics. Described here is the initial evaluation of the roles of source geometry and working parameters, including electrolytic solution composition and plasma current, on the response of caffeine residues, with preliminary limits of detection based on the relative standard deviation of the spectral background suggested to be on the 10-pg level. Demonstrative spectra are presented for green tea extracts and raw leaves, coffee beans, a dried (raw) tobacco leaf, an analgesic tablet, and paper currency. Versatility is further revealed through the determination of components in common cigarette smoke. In each case, the spectra are characterized by (M + H)(+) species of the expected constituents. The capacity for a single source to perform both in solution and particulate elemental analysis (as shown previously) and ADI of molecular species is unique in the realm of mass spectrometry.

  15. Counter-facing plasma focus system as an efficient and long-pulse EUV light source

    Science.gov (United States)

    Kuwabara, H.; Hayashi, K.; Kuroda, Y.; Nose, H.; Hotozuka, K.; Nakajima, M.; Horioka, K.

    2011-04-01

    A plasma focus system composed of a pair of counter-facing coaxial plasma guns is proposed as a long-pulse and efficient EUV light source. A proof-of-concept experiment demonstrated that with an assist of breakdown and outer electrode connections, current sheets evolved into a configuration for stable plasma confinement at the center of the electrode. The current sheets could successively compress and confine the high energy density plasma every half period of the discharge current, enabling highly repetitive light emissions in extreme ultraviolet region with time duration in at least ten microseconds for Xe plasma. Also, we confirmed operations of our system for Li plasma. We estimated the highest EUV energy in Li plasma operation at 93mJ/4π sr per 2% bandwidth per pulse.

  16. Injection of auxiliary electrons for increasing the plasma density in highly charged and high intensity ion sources

    Science.gov (United States)

    Odorici, F.; Malferrari, L.; Montanari, A.; Rizzoli, R.; Mascali, D.; Castro, G.; Celona, L.; Gammino, S.; Neri, L.

    2016-02-01

    Different electron guns based on cold- or hot-cathode technologies have been developed since 2009 at INFN for operating within ECR plasma chambers as sources of auxiliary electrons, with the aim of boosting the source performances by means of a higher plasma lifetime and density. Their application to microwave discharge ion sources, where plasma is not confined, has required an improvement of the gun design, in order to "screen" the cathode from the plasma particles. Experimental tests carried out on a plasma reactor show a boost of the plasma density, ranging from 10% to 90% when the electron guns are used, as explained by plasma diffusion models.

  17. Injection of auxiliary electrons for increasing the plasma density in highly charged and high intensity ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Odorici, F., E-mail: fabrizio.odorici@bo.infn.it; Malferrari, L.; Montanari, A. [INFN—Bologna, Viale B. Pichat, 6/2, 40127 Bologna (Italy); Rizzoli, R. [INFN—Bologna, Viale B. Pichat, 6/2, 40127 Bologna (Italy); CNR–Istituto per la Microelettronica ed i Microsistemi, Via Gobetti 101, 40129 Bologna (Italy); Mascali, D.; Castro, G.; Celona, L.; Gammino, S.; Neri, L. [INFN–Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy)

    2016-02-15

    Different electron guns based on cold- or hot-cathode technologies have been developed since 2009 at INFN for operating within ECR plasma chambers as sources of auxiliary electrons, with the aim of boosting the source performances by means of a higher plasma lifetime and density. Their application to microwave discharge ion sources, where plasma is not confined, has required an improvement of the gun design, in order to “screen” the cathode from the plasma particles. Experimental tests carried out on a plasma reactor show a boost of the plasma density, ranging from 10% to 90% when the electron guns are used, as explained by plasma diffusion models.

  18. Influence of instrumental parameters on the kinetic energy of ions and plasma temperature for a hexapole collision/reaction-cell-based inductively coupled plasma quadrupole mass spectrometer.

    Science.gov (United States)

    Favre, Georges; Brennetot, René; Chartier, Frédéric; Tortajada, Jeanine

    2009-02-01

    Inductively coupled plasma mass spectrometry (ICP-MS) is widely used in inorganic analytical chemistry for element and/or isotope ratio measurements. The presence of interferences, which is one of the main limitations of this method, has been addressed in recent years with the introduction of collision/reaction cell devices on ICP-MS apparatus. The study of ion-molecule reactions in the gas phase then became of great importance for the development of new analytical strategies. Knowing the kinetic energy and the electronic states of the ions prior to their entrance into the cell, i.e., just before they react, thereby constitutes crucial information for the interpretation of the observed reactivities. Such studies on an ICP-MS commonly used for routine analyses require the determination of the influence of different instrumental parameters on the energy of the ions and on the plasma temperature from where ions are sampled. The kinetic energy of ions prior to their entrance into the cell has been connected to the voltage applied to the hexapole according to a linear relationship determined from measurements of ion energy losses due to collisions with neutral gas molecules. The effects of the plasma forward power, sampling depth, and the addition of a torch shield to the ICP source were then examined. A decrease of the plasma potential due to the torch shielding, already mentioned in the literature, has been quantified in this study at about 3 V.

  19. Characterization of the Inductively Heated Plasma Source IPG6-B

    Science.gov (United States)

    Dropmann, Michael; Laufer, Rene; Herdrich, Georg; Matthews, Lorin; Hyde, Truell

    2014-10-01

    In close collaboration between the Center for Astrophysics, Space Physics and Engineering Research (CASPER) at Baylor University, Texas, and the Institute of Space Systems (IRS) at the University of Stuttgart, Germany, two plasma facilities have been established using the Inductively heated Plasma Generator 6 (IPG6). The facility at Baylor University (IPG6-B) works at a frequency of 13.56 MHz and a maximum power of 15 kW. A vacuum pump of 160 m3/h in combination with a butterfly valve allows pressure control over a wide range. Intended fields of research include basic investigation into thermo-chemistry and plasma radiation, space plasma environments and high heat fluxes e.g. those found in fusion devices or during atmospheric re-entry of spacecraft. After moving the IPG6-B facility to the Baylor Research and Innovation Collaborative (BRIC) it was placed back into operation during the summer of 2014. Initial characterization in the new lab, using a heat flux probe, Pitot probe and cavity calorimeter, has been conducted for Air, Argon and Helium. The results of this characterization are presented.

  20. A solar powered handheld plasma source for microbial decontamination applications

    Science.gov (United States)

    Ni, Y.; Lynch, M. J.; Modic, M.; Whalley, R. D.; Walsh, J. L.

    2016-09-01

    A fully portable atmospheric pressure air plasma system is reported to be suitable for the microbial decontamination of both surfaces and liquids. The device operates in quiescent air, and includes an integrated battery which is charged from a solar cell and weighs less than 750 g, making it highly amenable for a wide variety of applications beyond the laboratory. Using particle imaging velocimetry to visualise air flows around the device, the geometric configuration of the plasma generating electrodes was enhanced to induce a gas flow on the order of 0.5 m s-1 directed towards a sample placed downstream, thus improving the transport of plasma generated reactive species to the sample. The microbial decontamination efficiency of the system was assessed using potable water samples inoculated with common waterborne organisms Escherichia coli and Pseudomonas fluorescens. The reduction in the number of microorganisms was found to be in the range of 2-8 log and was strongly dependent on the plasma generation conditions.

  1. High-density operation of the Proto-MPEX High Intensity Plasma Source

    Science.gov (United States)

    Caughman, J. B. O.; Goulding, R. H.; Biewer, T. M.; Bigelow, T. S.; Campbell, I. H.; Caneses, J.; Diem, S. J.; Martin, E. H.; Parish, C. M.; Rapp, J.; Ray, H. B.; Shaw, G. C.; Showers, M. A.; Donovan, D.; Piotrowicz, P. A.; Martin, D. C.

    2016-10-01

    The Prototype Materials Plasma Experiment (Proto-MPEX) is a linear high-intensity RF plasma source that combines a high-density helicon plasma generator with ion and electron heating sections. It is being used to study the physics of heating over-dense plasmas in a linear configuration with the goal of delivering a plasma heat flux of 10 MW/m2 at a target. The helicon plasma is produced by coupling 13.56 MHz RF power at levels of >100 kW. A 30 kW ion cyclotron antenna has recently been installed, and microwaves at 28 GHz ( 150 kW) are coupled to the electrons in the over-dense helicon plasma via Electron Bernstein Waves (EBW). High plasma densities near the target have been produced in D ( 5 x1019/m3) , and electron temperatures range from 3 to >10 eV, depending on the source parameters. IR camera images of the target plate indicate plasma heat depositions >10 MW/m2 for some operating conditions. Details of the experimental results of the operational domain with respect to Te and ne as well as results from initial plasma material interaction tests will be presented. ORNL is managed by UT-Battelle, LLC, for the U.S. DOE under contract DE-AC-05-00OR22725.

  2. Optimization of negative ion current in a compact microwave driven upper hybrid resonance multicusp plasma source.

    Science.gov (United States)

    Sahu, D; Bhattacharjee, S; Singh, M J; Bandyopadhyay, M; Chakraborty, A

    2012-02-01

    Performance of a microwave driven upper hybrid resonance multicusp plasma source as a volume negative ion source is reported. Microwaves are directly launched into the plasma chamber predominantly in the TE(11) mode. The source is operated at different discharge conditions to obtain the optimized negative H(-) ion current which is ∼33 μA (0.26 mA∕cm(2)). Particle balance equations are solved to estimate the negative ion density, which is compared with the experimental results. Future prospects of the source are discussed.

  3. 微波消解-电感耦合等离子体质谱法快速鉴别巧克力中可可脂来源%Identification of the source of cocoa butter in chocolate by inductively coupled plasma-mass spectrometry with microwave digestion

    Institute of Scientific and Technical Information of China (English)

    宋晓华; 杨丽君; 张玉春; 崔凤杰; 时文春; 李金洺; 张迎康; 梁颖淑

    2016-01-01

    目的:采用微波消解-电感耦合等离子体质谱法(ICP-MS)快速鉴别巧克力中的可可脂来源。方法分别准确称取巧克力和代可可脂巧克力及可可原材料0.5000 g,加入5 mL浓硝酸经微波消解后定容至50 mL,上机检测铜离子含量。结果铜元素在添加水平为0.10、0.15 mg/kg的回收率为90.52%~100.83%,方法精密度1.4%,方法检出限为0.5 mg/kg。巧克力中铜元素含量大小关系:可可固形物50%以上>可可固形物50%以下>代可可脂巧克力。巧克力中可可固形物含量在85%以上铜元素含量和可可固形物和可可粉中的铜元素含量相当。结论通过ICP-MS法快速检测巧克力中的铜元素可以简单便捷地鉴别巧克力中可可脂来源属性。%ABSTRACT:Objective To rapid identification of the source of cocoa butter in chocolate by inductively coupled plasma-mass spectrometry (ICP-MS) with microwave digestion. Methods The chocolate, cocoa butter chocolate and cocoa raw materials were accurately took 0.5000 g, respectively, added 5 mL concentrated nitric acid for microwave digestion and fixed capacity to 50 mL. The content of copper was analyzed. Results The recoveries of the method with the spiked levels of 0.10 and 0.15 mg/kg were 90.52%~100.83%, the relative standard deviation (RSD) was less than 1.4%, and the detection limit was 0.5 mg/kg. The order of content of Cu in chocolate were as follows:cocoa solids above 50%>cocoa solids below 50%>cocoa butter replacers. The content of Cu in chocolate with cocoa solids above 85%was comparable to the Cu content in cocoa solids and cocoa powder. Conclusion The proposed method is feasible to identify the source of cocoa butter in chocolate simply and conveniently.

  4. 微波消解-电感耦合等离子体质谱法快速鉴别巧克力中可可脂来源%Identification of the source of cocoa butter in chocolate by inductively coupled plasma-mass spectrometry with microwave digestion

    Institute of Scientific and Technical Information of China (English)

    宋晓华; 杨丽君; 张玉春; 崔凤杰; 时文春; 李金洺; 张迎康; 梁颖淑

    2016-01-01

    Objective To rapid identification of the source of cocoa butter in chocolate by inductively coupled plasma-mass spectrometry (ICP-MS) with microwave digestion.MethodsThe chocolate, cocoa butter chocolate and cocoa raw materials were accurately took 0.5000 g, respectively, added 5 mL concentrated nitric acid for microwave digestion and fixed capacity to 50 mL. The content of copper was analyzed.Results The recoveries of the method with the spiked levels of 0.10 and 0.15 mg/kg were 90.52%~100.83%, the relative standard deviation (RSD) was less than 1.4%, and the detection limit was 0.5 mg/kg.The order of content of Cu in chocolate were as follows: cocoa solids above 50%> cocoa solids below 50%>cocoa butterreplacers. The content of Cu in chocolate with cocoa solids above85% was comparable to the Cu content in cocoa solids and cocoa powder.ConclusionThe proposed method is feasible to identify the source of cocoa butter in chocolate simply and conveniently.%目的:采用微波消解-电感耦合等离子体质谱法(ICP-MS)快速鉴别巧克力中的可可脂来源。方法分别准确称取巧克力和代可可脂巧克力及可可原材料0.5000 g,加入5 mL浓硝酸经微波消解后定容至50 mL,上机检测铜离子含量。结果铜元素在添加水平为0.10、0.15 mg/kg的回收率为90.52%~100.83%,方法精密度1.4%,方法检出限为0.5 mg/kg。巧克力中铜元素含量大小关系:可可固形物50%以上>可可固形物50%以下>代可可脂巧克力。巧克力中可可固形物含量在85%以上铜元素含量和可可固形物和可可粉中的铜元素含量相当。结论通过ICP-MS法快速检测巧克力中的铜元素可以简单便捷地鉴别巧克力中可可脂来源属性。

  5. Improving low-level plasma protein mass spectrometry-based detection for candidate biomarker discovery and validation

    Energy Technology Data Exchange (ETDEWEB)

    Page, Jason S.; Kelly, Ryan T.; Camp, David G.; Smith, Richard D.

    2008-09-01

    Methods. To improve the detection of low abundance protein candidate biomarker discovery and validation, particularly in complex biological fluids such as blood plasma, increased sensitivity is desired using mass spectrometry (MS)-based instrumentation. A key current limitation on the sensitivity of electrospray ionization (ESI) MS is due to the fact that many sample molecules in solution are never ionized, and the vast majority of the ions that are created are lost during transmission from atmospheric pressure to the low pressure region of the mass analyzer. Two key technologies, multi-nanoelectrospray emitters and the electrodynamic ion funnel have recently been developed and refined at Pacific Northwest National Laboratory (PNNL) to greatly improve the ionization and transmission efficiency of ESI MS based analyses. Multi-emitter based ESI enables the flow from a single source (typically a liquid chromatography [LC] column) to be divided among an array of emitters (Figure 1). The flow rate delivered to each emitter is thus reduced, allowing the well-documented benefits of nanoelectrospray 1 for both sensitivity and quantitation to be realized for higher flow rate separations. To complement the increased ionization efficiency afforded by multi-ESI, tandem electrodynamic ion funnels have also been developed at PNNL, and shown to greatly improve ion transmission efficiency in the ion source interface.2, 3 These technologies have been integrated into a triple quadrupole mass spectrometer for multiple reaction monitoring (MRM) of probable biomarker candidates in blood plasma and show promise for the identification of new species even at low level concentrations.

  6. Blazing trails: Microquasars as head-tail sources and the seeding of magnetized plasma into the ISM

    CERN Document Server

    Heinz, S; Sunyaev, R A; Fender, R P

    2008-01-01

    We discuss the dynamics of microquasar jets in the interstellar medium, with specific focus on the effects of the X-ray binaries' space velocity with respect to the local Galactic standard of rest. We argue that, during late stages in the evolution of large scale radio nebulae around microquasars, the ram pressure of the interstellar medium due to the microquasar's space velocity becomes important and that microquasars with high velocities form the Galactic equivalent of extragalactic head-tail sources, i.e., that they leave behind trails of stripped radio plasma. Because of their higher space velocities, low-mass X-ray binaries are more likely to leave trails than high-mass X-ray binaries. We show that the volume of radio plasma released by microquasars over the history of the Galaxy is comparable to the disk volume and argue that a fraction of a few percent of the radio plasma left behind by the X-ray binary is likely mixed with the neutral phases of the ISM before the plasma is removed from the disk by buo...

  7. Mass spectroscopy of the ion flux produced during inductively coupled plasma nitriding process

    Science.gov (United States)

    Kolodko, D. V.; Kaziev, A. V.; Ageychenkov, D. G.; Meshcheryakova, E. A.; Pisarev, A. A.; Tumarkin, A. V.

    2017-05-01

    Ion fluxes on the surface of sample embedded in inductively coupled plasma have been studied in conditions typical for titanium alloy nitriding: total pressure 0.44 Pa, Ar/N2 = 70%/30%, and RF power 1500 W. The gas composition was independently monitored by the quadrupole analyser. The ion fluxes were sampled using a specially designed electrostatic extractor and then analysed with a magnetic sector mass-separator. The extractor design allowed us to apply a bias voltage to the plasma facing electrode thus imitating interaction of ions with the surface during the plasma processing. The ion fluxes of Ar+, {{{N}}}2{}+, and N+ on the surface were measured. The mass spectroscopy diagnostics unit is suitable for extensive ion content studies in the plasma technology facilities.

  8. Operation of a microwave plasma source for electron heating and antenna testing

    Science.gov (United States)

    Caughman, J. B. O.; Bigelow, T. S.; Diem, S. J.; Goulding, R. H.; Rasmussen, D. A.; Schaich, C. R.; White, T. L.

    2011-10-01

    One of the major challenges for magnetic fusion is the interaction of the plasma with materials. Linear plasma-material interaction test stands can benefit from additional electron heating of the high-density source plasma to increase the total plasma heat flux at the target to better simulate fusion reactor conditions (10-20 MW/m2). A microwave-based plasma experiment has begun at ORNL to study electron heating of over-dense plasmas and to provide a plasma environment for antenna testing. The plasma is generated by high-field launched whistler waves at 18 GHz to create a moderate-density plasma (ne ~1018/m3). Electron heating of the over-dense plasma is provided by either whistler waves or electron Bernstein waves at 6 GHz. In addition, a single strap mockup antenna, designed to operate at 40-50 MHz, is being constructed to study near-field plasma interactions. The antenna will be placed in the experiment's central vacuum chamber, which will act as an rf test facility. ORNL is managed by UT-Battelle, LLC, for the U.S. DOE under contract DE-AC-05-00OR22725.

  9. High power microwave source for a plasma wakefield experiment

    Science.gov (United States)

    Shafir, G.; Shlapakovski, A.; Siman-Tov, M.; Bliokh, Yu.; Leopold, J. G.; Gleizer, S.; Gad, R.; Rostov, V. V.; Krasik, Ya. E.

    2017-01-01

    The results of the generation of a high-power microwave (˜550 MW, 0.5 ns, ˜9.6 GHz) beam and feasibility of wakefield-excitation with this beam in under-dense plasma are presented. The microwave beam is generated by a backward wave oscillator (BWO) operating in the superradiance regime. The BWO is driven by a high-current electron beam (˜250 keV, ˜1.5 kA, ˜5 ns) propagating through a slow-wave structure in a guiding magnetic field of 2.5 T. The microwave beam is focused at the desired location by a dielectric lens. Experimentally obtained parameters of the microwave beam at its waist are used for numerical simulations, the results of which demonstrate the formation of a bubble in the plasma that has almost 100% electron density modulation and longitudinal and transverse electric fields of several kV/cm.

  10. Ionized PVD with an Inductively Coupled Plasma Source

    Science.gov (United States)

    Hayden, D. B.; Juliano, D. R.; Ruzic, D. N.

    1997-10-01

    Ionized physical vapor deposition (iPVD) is used to enhance the directionality of metal deposition. This is a potential solution to depositing into higher aspect-ratio trenches and vias for metal interconnects. A dc magnetron (Donated by Materials Research Corporation) is coupled with an inductively coupled plasma (ICP) coil to increase the ionization of the sputtered metal atoms. This allows metal ions to be accelerated across the plasma sheath to a biased substrate and deposited normally. One coil design has a wider diameter than the substrate to reduce shadowing and flaking effects. Argon and neon working gases and aluminum and copper targets are investigated at varying pressures and power levels. Deposition rates and metal flux ionization fractions are measured with a quartz crystal microbalance and a multi-grid analyzer.

  11. Stable droplet generator for a high brightness laser produced plasma extreme ultraviolet source

    Science.gov (United States)

    Vinokhodov, A.; Krivokorytov, M.; Sidelnikov, Yu.; Krivtsun, V.; Medvedev, V.; Bushuev, V.; Koshelev, K.; Glushkov, D.; Ellwi, S.

    2016-10-01

    We present the results of the low-melting liquid metal droplets generation based on excited Rayleigh jet breakup. We discuss on the operation of the industrial and in-house designed and manufactured dispensing devices for the droplets generation. Droplet diameter can be varied in the range of 30-90 μm. The working frequency of the droplets, velocity, and the operating temperature were in the ranges of 20-150 kHz, 4-15 m/s, and up to 250 °C, respectively. The standard deviations for the droplet center of mass position both their diameter σ < 1 μm at the distance of 45 mm from the nozzle. Stable operation in the long-term (over 1.5 h) was demonstrated for a wide range of the droplet parameters: diameters, frequencies, and velocities. Physical factors affecting the stability of the generator operation have been identified. The technique for droplet synchronization, allowing using the droplet as a target for laser produced plasma, has been created; in particular, the generator has been successfully used in a high brightness extreme ultraviolet (EUV) light source. The operation with frequency up to 8 kHz was demonstrated as a result of the experimental simulation, which can provide an average brightness of the EUV source up to ˜1.2 kW/mm2 sr.

  12. Proteomic biomarker discovery in 1000 human plasma samples with mass spectrometry

    DEFF Research Database (Denmark)

    Cominetti, Ornella; Núñez Galindo, Antonio; Corthésy, John

    2016-01-01

    the quality of the MS data and provided descriptive statistics. The data set was interrogated for proteins with most stable expression levels in that set of plasma samples. We evaluated standard clinical variables that typically impact forthcoming results and assessed body mass index-associated and gender......-specific proteins at two time points. We demonstrate that analyzing a large number of human plasma samples for biomarker discovery with MS using isobaric tagging is feasible, providing robust and consistent biological results....

  13. Diagnostics of low and atmospheric pressure plasmas by means of mass spectrometry

    CERN Document Server

    Benedikt, Jan; von Keudell, Achim

    2011-01-01

    The knowledge of absolute fluxes of reactive species such as radicals or energetic ions to the surface is crucial for understanding the growth or etching of thin films. These species have due to their high reactivity very low densities and their detection is therefore a challenging task. Mass spectrometry is a very sensitive technique and it will be demonstrated that it is a good choice for the study of plasma chemistry. Mass spectrometry measures the plasma composition directly at the surface and is not limited by existence of accessible optical transitions. When properly designed and carefully calibrated mass spectrometry provides absolute densities of the measured species. It can even measure internally excited metastable species. Here, measurement of neutral species and positive ions generated in an atmospheric pressure plasmas jet operated with He, hexamethyldisiloxane and O2 will be presented.

  14. Microstructure and Properties of Plasma Source Nitrided AISI 316 Austenitic Stainless Steel

    Science.gov (United States)

    Li, G. Y.; Lei, M. K.

    2016-11-01

    Plasma source nitriding is a relatively new nitriding technology which can overcome those inherent shortcomings associated with conventional direct current plasma nitriding technology such as the arcing surface damage, the edging effect and the hollow cathode effect. There is considerable study on the properties of nitrided samples for laboratorial scale plasma source nitriding system; however, little information has been reported on the industrial-scale plasma source nitriding system. In this work, AISI 316 austenitic stainless steel samples were nitrided by an industrial-scale plasma source nitriding system at various nitriding temperatures (350, 400, 450 and 500 °C) with a floating potential. A high-nitrogen face-centered-cubic phase (γN) formed on the surface of nitrided sample surface. As the nitriding temperature was increased, the γN phase layer thickness increased, varying from 1.5 μm for the lowest nitriding temperature of 350 °C, to 30 μm for the highest nitriding temperature of 500 °C. The maximum Vickers microhardness of the γN phase layer with a peak nitrogen concentration of 20 at.% is about HV 0.1 N 15.1 GPa at the nitriding temperature of 450 °C. The wear and corrosion experimental results demonstrated that the γN phase was formed on the surface of AISI 316 austenitic stainless steel by plasma source nitriding, which exhibits not only high wear resistance, but also good pitting corrosion resistance.

  15. Plasma characteristics in inductively and capacitively coupled hybrid source using single RF power

    Science.gov (United States)

    Kim, Kwan-Yong; Lee, Moo-Young; Kim, Tae-Woo; Kim, Ju-Ho; Chung, Chin-Wook

    2016-09-01

    Parallel combined inductively coupled plasma (ICP) and capacitively coupled plasma (CCP) using single RF generator was proposed to linear control of the plasma density with RF power. In the case of ICP, linear control of the plasma density is difficult because there is a density jump up due to E to H transition. Although the plasma density of CCP changes linearly with power, the density is lower than that of ICP due to high ion energy loss at the substrate. In our hybrid source, the single RF power generator was connected to electrode and antenna, and the variable capacitor was installed between the antenna and the power generator to control the current flowing through the antenna and the electrode. By adjusting the current ratio between the antenna and the electrode, linear characteristic of plasma density with RF power is achieved.

  16. What are the Sources of Solar Energetic Particles? Element Abundances and Source Plasma Temperatures

    CERN Document Server

    Reames, Donald V

    2015-01-01

    We have spent 50 years in heated discussion over which populations of solar energetic particles (SEPs) are accelerated at flares and which by shock waves driven out from the Sun by coronal mass ejections (CMEs). The association of the large "gradual" SEP events with shock acceleration is supported by the extensive spatial distribution of SEPs and by the delayed acceleration of the particles. The relative abundances of the elements in these gradual events are a measure of those in the ambient solar corona, differing from those in the photosphere by a widely-observed function of the first ionization potential (FIP) of the elements. SEP events we call "impulsive", the traditional "3He-rich" events with enhanced heavy-element abundances, are associated with type III radio bursts, flares, and narrow CMEs; they selectively populate flux tubes that thread a localized source, and they are fit to new particle-in-cell models of magnetic reconnection on open field lines as found in solar jets. These models help explain ...

  17. Direct analysis of samples by mass spectrometry: From elements to bio-molecules using laser ablation inductively couple plasma mass spectrometry and laser desorption/ionization mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Perdian, David C. [Iowa State Univ., Ames, IA (United States)

    2009-01-01

    Mass spectrometric methods that are able to analyze solid samples or biological materials with little or no sample preparation are invaluable to science as well as society. Fundamental research that has discovered experimental and instrumental parameters that inhibit fractionation effects that occur during the quantification of elemental species in solid samples by laser ablation inductively coupled plasma mass spectrometry is described. Research that determines the effectiveness of novel laser desorption/ionization mass spectrometric methods for the molecular analysis of biological tissues at atmospheric pressure and at high spatial resolution is also described. A spatial resolution is achieved that is able to analyze samples at the single cell level.

  18. US-Japan IEC Workshop on Small Plasma and Accelerator Neutron Sources

    Energy Technology Data Exchange (ETDEWEB)

    Miley, George H. [Univ. of Illinois, Champaign, IL (United States). Dept. of Nuclear, Plasma, and Radiological Engineering

    2007-05-25

    This report lays out the agenda for the entire workshop and then lists the abstracts for all 29 presentations. All of these presentations cover small plasma and accelerator neutron sources. A few of the presentations include: Comments about IEC History and Future Directions; Characteristics in Pulse Operation of IEC Device with Confronting Two Plasma Sources; Overview of the University of Wisconsin-Madison IEC Program; Improving IEC Particle Confinement Times Using Multiple Grids; Integral Transport Approach for Molecular Ion Processes in IEC Devices; A Counter Stream Beam D-D Neutron Generator; Low Pressure IECF Operation Using Differentially-Pumped Ion Sources, and more.

  19. High-resolution VUV spectrometer/detector investigations of rare-earth pulsed plasma source (abstract)

    Science.gov (United States)

    Roberts, J. R.; Cromer, C. L.; Bridges, J. M.; Lucatorto, T. B.

    1985-05-01

    A 1.5-m grazing incidence spectrometer with a channel electron multiplier (CEMA) and electronic readout detector has been incorporated with a rare-earth target, pulsed plasma, continuum source. The spectrometer is compact and portable while maintaining high resolution. The CEMA detector consists of a single multichannel plate (MCP) with coned-shaped input pores which are cut at a 15-degree bias to improve efficiency at grazing angles. The source is a rare-earth plasma generated by a 10-J ruby laser producing intense continuum emission for wavelengths from 170 to 5 nm. This system will be used for both stationary and transient high-resolution atomic photoabsorption spectroscopy. The pulsed plasma source itself will be investigated for suitability as a radiometric transfer standard source. Preliminary results obtained with this integrated system will be discussed.

  20. Electrospray ionization Fourier transform mass spectrometric analysis of intact bikunin glycosaminoglycan from normal human plasma.

    Science.gov (United States)

    Laremore, Tatiana N; Leach, Franklin E; Amster, I Jonathan; Linhardt, Robert J

    2011-08-15

    A mixture of glycosaminoglycan (GAG) chains from a plasma proteoglycan bikunin was fractionated using native, continuous-elution polyacrylamide gel electrophoresis, and the resulting fractions were analyzed by electrospray ionization Fourier transform mass spectrometry (ESI FTMS). Molecular mass analysis of the intact GAG afforded information about the length and composition of GAG chains in the mixture. Ambiguity in the interpretation of the intact GAG mass spectra was eliminated by conducting an additional experiment in which the GAG chains of known molecular mass were treated with a GAG-degrading enzyme, chondroitinase ABC, and the digestion products were analyzed by ESI FTMS. The plasma bikunin GAG chains consisted predominantly of odd number of saccharides, although few chains consisting of even number of saccharides were also detected. Majority of the analyzed chains were tetrasulfated or pentasulfated and comprised by 29 to 41 monosaccharides.

  1. Inductively coupled plasma mass spectrometer with laser ablation metal ions release detection in the human mouth

    Science.gov (United States)

    Kueerova, Hana; Dostalova, Tatjana; Prochazkova, J.

    2002-06-01

    Presence of more dental alloys in oral cavity often causes pathological symptoms. Due to various and multi-faced symptomatology, they tend to be a source of significant problems not only for the patient but also for the dentist. Metal ions released from alloys can cause subjective and objective symptoms in mouth. The aim of this study was detection of metal elements presence in saliva. There were 4 groups of examined persons: with intact teeth (15 individuals) with metallic restorations, pathological currents 5-30 (mu) A, multi-faced subjective symptomatology and uncharacteristic objective diagnosis (32 patients), with metallic restorations and no subjective symptoms (14 persons) and with metallic restorations, without pathological currents and with problems related to galvanism (13 patients). Presence of 14 metal elements was checked by inductively coupled plasma mass spectrometer with laser ablation. Nd:YAG laser detector was used. There were significant differences in content of silver, gold and mercury between persons with intact teeth and other three groups. There were no differences found between subjects with and without galvanic currents, and presence of subjective and objective symptoms.

  2. Investigations into the origins of polyatomic ions in inductively coupled plasma-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    McIntyre, Sally M. [Iowa State Univ., Ames, IA (United States)

    2010-01-01

    An inductively coupled plasma-mass spectrometer (ICP-MS) is an elemental analytical instrument capable of determining nearly all elements in the periodic table at limits of detection in the parts per quadrillion and with a linear analytical range over 8-10 orders of magnitude. Three concentric quartz tubes make up the plasma torch. Argon gas is spiraled through the outer tube and generates the plasma powered by a looped load coil operating at 27.1 or 40.6 MHz. The argon flow of the middle channel is used to keep the plasma above the innermost tube through which solid or aqueous sample is carried in a third argon stream. A sample is progressively desolvated, atomized and ionized. The torch is operated at atmospheric pressure. To reach the reduced pressures of mass spectrometers, ions are extracted through a series of two, approximately one millimeter wide, circular apertures set in water cooled metal cones. The space between the cones is evacuated to approximately one torr. The space behind the second cone is pumped down to, or near to, the pressure needed for the mass spectrometer (MS). The first cone, called the sampler, is placed directly in the plasma plume and its position is adjusted to the point where atomic ions are most abundant. The hot plasma gas expands through the sampler orifice and in this expansion is placed the second cone, called the skimmer. After the skimmer traditional MS designs are employed, i.e. quadrupoles, magnetic sectors, time-of-flight. ICP-MS is the leading trace element analysis technique. One of its weaknesses are polyatomic ions. This dissertation has added to the fundamental understanding of some of these polyatomic ions, their origins and behavior. Although mainly continuing the work of others, certain novel approaches have been introduced here. Chapter 2 includes the first reported efforts to include high temperature corrections to the partition functions of the polyatomic ions in ICP-MS. This and other objections to preceeding

  3. Investigations into the origins of polyatomic ions in inductively coupled plasma-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    McIntyre, Sally M. [Iowa State Univ., Ames, IA (United States)

    2010-01-01

    An inductively coupled plasma-mass spectrometer (ICP-MS) is an elemental analytical instrument capable of determining nearly all elements in the periodic table at limits of detection in the parts per quadrillion and with a linear analytical range over 8-10 orders of magnitude. Three concentric quartz tubes make up the plasma torch. Argon gas is spiraled through the outer tube and generates the plasma powered by a looped load coil operating at 27.1 or 40.6 MHz. The argon flow of the middle channel is used to keep the plasma above the innermost tube through which solid or aqueous sample is carried in a third argon stream. A sample is progressively desolvated, atomized and ionized. The torch is operated at atmospheric pressure. To reach the reduced pressures of mass spectrometers, ions are extracted through a series of two, approximately one millimeter wide, circular apertures set in water cooled metal cones. The space between the cones is evacuated to approximately one torr. The space behind the second cone is pumped down to, or near to, the pressure needed for the mass spectrometer (MS). The first cone, called the sampler, is placed directly in the plasma plume and its position is adjusted to the point where atomic ions are most abundant. The hot plasma gas expands through the sampler orifice and in this expansion is placed the second cone, called the skimmer. After the skimmer traditional MS designs are employed, i.e. quadrupoles, magnetic sectors, time-of-flight. ICP-MS is the leading trace element analysis technique. One of its weaknesses are polyatomic ions. This dissertation has added to the fundamental understanding of some of these polyatomic ions, their origins and behavior. Although mainly continuing the work of others, certain novel approaches have been introduced here. Chapter 2 includes the first reported efforts to include high temperature corrections to the partition functions of the polyatomic ions in ICP-MS. This and other objections to preceeding

  4. Simultaneous determination of piroxicam, meloxicam and tenoxicam in human plasma by liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Ji, Hye Young; Lee, Hye Won; Kim, Young Hoon; Jeong, Dong Won; Lee, Hye Suk

    2005-11-05

    A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for the determination of piroxicam, meloxicam and tenoxicam in human plasma was developed. Piroxicam, meloxicam, tenoxicam and isoxicam (internal standard) were extracted from human plasma with ethyl acetate at acidic pH and analyzed on a Sunfire column with the mobile phase of methanol:ammonium formate (15 mM, pH 3.0) (60:40, v/v). The analytes were detected using a mass spectrometer, equipped with electrospray ion source. The instrument was set in the multiple-reaction-monitoring (MRM) mode. The standard curve was linear (r=1.000) over the concentration range of 0.50-200 ng/ml. The coefficient of variation (CV) and relative error (RE) for intra- and inter-assay statistics at three QC levels were 1.0-5.4% and -5.9 to 2.8%, respectively. The recoveries of piroxicam, meloxicam and tenoxicam ranged from 78.3 to 87.1%, with that of isoxicam being 59.7%. The lower limit of quantification for piroxicam, meloxicam and tenoxicam was 0.50 ng/ml using a 100 microl plasma sample. This method was successfully applied to a pharmacokinetic study of piroxicam after application of transdermal piroxicam patches to humans.

  5. The role of plasma/neutral source and loss processes in shaping the giant planet magnetospheres

    Science.gov (United States)

    Delamere, P. A.

    2014-12-01

    The giant planet magnetospheres are filled with neutral and ionized gases originating from satellites orbiting deep within the magnetosphere. The complex chemical and physical pathways for the flow of mass and energy in this partially ionized plasma environment is critical for understanding magnetospheric dynamics. The flow of mass at Jupiter and Saturn begins, primarily, with neutral gases emanating from Io (~1000 kg/s) and Enceladus (~200 kg/s). In addition to ionization losses, the neutral gases are absorbed by the planet, its rings, or escape at high speeds from the magnetosphere via charge exchange reactions. The net result is a centrifugally confined torus of plasma that is transported radially outward, distorting the magnetic field into a magnetodisc configuration. Ultimately the plasma is lost to the solar wind. A critical parameter for shaping the magnetodisc and determining its dynamics is the radial plasma mass transport rate (~500 kg/s and ~50 kg/s for Jupiter and Saturn respectively). Given the plasma transport rates, several simple properties of the giant magnetodiscs can be estimated including the physical scale of the magnetosphere, the magnetic flux transport, and the magnitude of azimuthal magnetic field bendback. We will discuss transport-related magnetic flux conservation and the mystery of plasma heating—two critical issues for shaping the giant planet magnetospheres.

  6. High Power Light Gas Helicon Plasma Source for VASIMR

    Science.gov (United States)

    Squire, Jared P.; Chang-Diaz, Franklin R.; Glover, Timothy W.; Jacobson, Verlin T.; Baity, F. Wally; Carter, Mark D.; Goulding, Richard H.

    2004-01-01

    In the Advanced Space Propulsion Laboratory (ASPL) helicon experiment (VX-10) we have measured a plasma flux to input gas rate ratio near 100% for both helium and deuterium at power levels up to 10 kW. Recent results at Oak Ridge National Laboratory (ORNL) show enhanced efficiency operation with a high power density, over 5 kW in a 5 cm diameter tube. Our helicon is presently 9 cm in diameter and operates up to 10 kW of input power. The data here uses a Boswell double-saddle antenna design with a magnetic cusp just upstream of the antenna. Similar to ORNL, for deuterium at near 10 kW, we find an enhanced performance of operation at magnetic fields above the lower hybrid matching condition.

  7. High Power Light Gas Helicon Plasma Source for VASIMR

    Science.gov (United States)

    Squire, Jared P.; Chang-Diaz, Franklin R.; Glover, Timothy W.; Jacobson, Verlin T.; Baity, F. Wally; Carter, Mark D.; Goulding, Richard H.

    2004-01-01

    In the Advanced Space Propulsion Laboratory (ASPL) helicon experiment (VX-10) we have measured a plasma flux to input gas rate ratio near 100% for both helium and deuterium at power levels up to 10 kW. Recent results at Oak Ridge National Laboratory (ORNL) show enhanced efficiency operation with a high power density, over 5 kW in a 5 cm diameter tube. Our helicon is presently 9 cm in diameter and operates up to 10 kW of input power. The data here uses a Boswell double-saddle antenna design with a magnetic cusp just upstream of the antenna. Similar to ORNL, for deuterium at near 10 kW, we find an enhanced performance of operation at magnetic fields above the lower hybrid matching condition.

  8. Environmental friendly high efficient light source plasma lamp - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Courret, G.; Calame, L. [Haute Ecole d' ingenierie et de gestion du canton de Vaud, Institut de micro et nano techniques, Yverdon-les-Bains (Switzerland); Meyer, A. [Solaronix SA, Aubonne (Switzerland)

    2007-07-01

    This illustrated final report for the Swiss Federal Office of Energy (SFOE) takes a look at work done on the development of a sulphur-based plasma lamp. In 2007, the capability of a new modulator has been explored. The most important results are discussed. With the production of a 1.2 cm{sup 3} bulb, the way towards the production of a 100 W lamp has been opened. The authors comment that modulation by impulses increases the luminous efficiency in comparison to modulation using a continuous sinusoidal wave. The report deals with the history of the project, the development of the new modulator, the use of rotational effects and the optimisation of the amount of active substances - tellurium and selenium - in the bulb. The electromagnetic coupling system used is described and discussed.

  9. Low temperature plasmas created by photoionization of gases with intense radiation pulses from laser-produced plasma sources

    Science.gov (United States)

    Bartnik, A.; Pisarczyk, T.; Wachulak, P.; Chodukowski, T.; Fok, T.; Wegrzyński, Ł.; Kalinowska, Z.; Fiedorowicz, H.

    2016-12-01

    A comparative study of photoionized plasmas created by soft X-ray (SXR) and extreme ultraviolet (EUV) laser plasma sources was performed. The sources, employing high or low energy laser systems, utilized double-stream Xe/He gas-puff targets irradiated with laser pulses of different parameters. The SXR/EUV beams were used for irradiation of a gas stream, injected into a vacuum chamber synchronously with the radiation pulse. Photoionized plasmas produced this way in Ne gas emitted radiation in the SXR/EUV range. The corresponding spectra were dominated by emission lines originating from singly charged ions. Significant differences between spectra obtained in different experimental conditions concern specific transitions in Ne II ions. Creation of photoionized plasmas by SXR or EUV irradiation resulted in K-shell or L-shell emissions respectively. In case of the low energy system absorption spectra were measured additionally. In case of the high energy system, the electron density measurements were performed by laser interferometry, employing a femtosecond laser system. A maximum electron density reached the value of 2·1018cm-3. For the low energy system, a detection limit was too high for the interferometric measurements, thus only an upper estimation for electron density could be made.

  10. The effects of analyte mass and collision gases on ion beam formation in an inductively coupled plasma mass spectrometer

    Science.gov (United States)

    Larsen, Jessica J.; Edmund, Alisa J.; Farnsworth, Paul B.

    2016-11-01

    Planar laser induced fluorescence (PLIF) was used to evaluate the effect of matrix components on the formation and focusing of a Ba ion beam in a commercial inductively coupled plasma mass spectrometer. Cross sections of the ion beams were taken in the second vacuum stage, in front of the entrance to the mass analyzer. Under normal operating conditions, the addition of Pb shifted the position of the Ba ion beam to the right. PLIF was also used to evaluate the effect of a collision reaction interface (CRI) on Ca and Ba ion beams. A wider velocity distribution of ions and a decrease in overall intensity were observed for the CRI images. The fluorescence and mass spectrometer signals decreased with increased CRI flow rates. These effects were most obvious for Ca ions with He gas.

  11. Accessibility condition of wave propagation and multicharged ion production in electron cyclotron resonance ion source plasma

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Yushi, E-mail: kato@eei.eng.osaka-u.ac.jp; Yano, Keisuke; Nishiokada, Takuya; Nagaya, Tomoki; Kimura, Daiju; Kumakura, Sho; Imai, Youta; Hagino, Shogo; Otsuka, Takuro; Sato, Fuminobu [Division of Electrical, Electronic and Information Engineering, Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita-shi, Osaka 565-0871 (Japan)

    2016-02-15

    A new tandem type source of electron cyclotron resonance (ECR) plasmas has been constructing for producing synthesized ion beams in Osaka University. Magnetic mirror field configuration with octupole magnets can be controlled to various shape of ECR zones, namely, in the 2nd stage plasma to be available by a pair mirror and a supplemental coil. Noteworthy correlations between these magnetic configurations and production of multicharged ions are investigated in detail, as well as their optimum conditions. We have been considering accessibility condition of electromagnetic and electrostatic waves propagating in ECR ion source plasma, and then investigated their correspondence relationships with production of multicharged ions. It has been clarified that there exits efficient configuration of ECR zones for producing multicharged ion beams experimentally, and then has been suggested from detail accessibility conditions on the ECR plasma that new resonance, i.e., upper hybrid resonance, must have occurred.

  12. Modelling of plasma behaviour in the vicinity of intensive impurity sources

    Science.gov (United States)

    Tokar, Mikhail Z.; Ding, Rui; Koltunov, Mikhail

    2010-07-01

    Plasma behaviour in the vicinity of strong sources of impurities is considered by taking into account quasi-neutrality, Coulomb collisions of background particles with impurity ions, radiation losses and sinks of charged particles to bounding material surfaces. If several ion species are present in the plasma the generalized Bohm criterion requires that a certain function of the main ion velocity changes its sign when moving along the magnetic field from the distant plasma through the impurity source to the surface. This allows us to formulate the 'regularity' conditions for the motion equation of the main ions and a numerical approach to find the only physical solution without singularities is elaborated. Calculations of plasma parameters in the shadow of a limiter, through which impurities are injected, have been done for the conditions of impurity seeding experiments in the tokamak TEXTOR.

  13. Documenting utility of paddlefish otoliths for quantification of metals using inductively coupled plasma mass spectrometry

    Science.gov (United States)

    Long, James M.; Schaffler, James J.

    2013-01-01

    RATIONALE The otoliths of the inner ear of fishes record the environment of their surrounding water throughout their life. For paddlefish (Polyodon spathula), otoliths have not been routinely used by scientists since their detriments were outlined in the early 1940s. We sought to determine if paddlefish otoliths were useful for resolving elemental information contained within. METHODS Adult paddlefish were collected from two wild, self-sustaining populations in Oklahoma reservoirs in the Arkansas River basin. Juveniles were obtained from a hatchery in the Red River basin of Oklahoma. Otoliths were removed and laser ablation, inductively coupled plasma mass spectrometry (ICP-MS) was used to quantify eight elements (Li, Mg, Mn, Rb, Sr, Y, Ba, and Pb) along the core and edge portions, which were analyzed for differences between otolith regions and among paddlefish sources. RESULTS Differences were found among samples for six of the eight elements examined. Otoliths from Red River basin paddlefish born in a hatchery had significantly lower amounts of Mg and Mn, but higher levels of Rb than otoliths from wild paddlefish in the Arkansas River basin. Concentrations of Y, Sr, and Ba were reduced on the edges of adult paddlefish from both reservoirs compared with the cores. CONCLUSIONS This research shows the utility of using an ICP-MS analysis of paddlefish otoliths. Future research that seeks to determine sources of paddlefish production, such as which reservoir tributaries are most important for reproduction or what proportion of the population is composed of wild versus hatchery-produced individuals, appears promising. Published in 2013. This article is a U.S. Government work and is in the public domain in the USA.

  14. Determination of Arsenic in Sinus Wash and Tap Water by Inductively Coupled Plasma-Mass Spectrometry

    Science.gov (United States)

    Donnell, Anna M.; Nahan, Keaton; Holloway, Dawone; Vonderheide, Anne P.

    2016-01-01

    Arsenic is a toxic element to which humans are primarily exposed through food and water; it occurs as a result of human activities and naturally from the earth's crust. An experiment was developed for a senior level analytical laboratory utilizing an Inductively Coupled Plasma-Mass Spectrometer (ICP-MS) for the analysis of arsenic in household…

  15. Independent prognostic value of left ventricular mass, diastolic function, and fasting plasma glucose

    DEFF Research Database (Denmark)

    Pareek, Manan; Nielsen, Mette Lundgren; Leósdóttir, Margrét

    2016-01-01

    OBJECTIVE: To explore the independent prognostic value of left ventricular (LV) mass, diastolic function, and fasting plasma glucose (FPG) for the prediction of incident cardiac events in a random population sample. DESIGN AND METHOD: 415 women and 999 men aged 56-79 years, included between 2002...

  16. Determination of platinum in human subcellular microsamples by inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Björn, Erik; Nygren, Yvonne; Nguyen, Tam T. T. N.

    2007-01-01

    A fast and robust method for the determination of platinum in human subcellular microsamples by inductively coupled plasma mass spectrometry was developed, characterized, and validated. Samples of isolated DNA and exosome fractions from human ovarian (2008) and melanoma (T289) cancer cell lines...

  17. Evolution of plasma parameters in a He - N2/Ar magnetic pole enhanced inductive plasma source

    Science.gov (United States)

    Younus, Maria; Rehman, N. U.; Shafiq, M.; Zakaullah, M.; Abrar, M.

    2016-02-01

    A magnetic pole enhanced inductively coupled H e - N2/A r plasma is studied at low pressure, to monitor the effects of helium mixing on plasma parameters like electron number density (ne) , electron temperature (Te) , plasma potential (Vp ) , and electron energy probability functions (EEPFs). An RF compensated Langmuir probe is employed to measure these plasma parameters. It is noted that electron number density increases with increasing RF power and helium concentration in the mixture, while it decreases with increase in filling gas pressure. On the other hand, electron temperature shows an increasing trend with helium concentration in the mixture. At low RF powers and low helium concentration in the mixture, EEPFs show a "bi-Maxwellian" distribution with pressure. While at RF powers greater than 50 W and higher helium concentration in the mixture, EEPFs evolve into "Maxwellian" distribution. The variation of skin depth with RF power and helium concentration in the mixture, and its relation with EEPF are also studied. The effect of helium concentrations on the temperatures of two electron groups ( Tb u l k and Tt a i l ) in the "bi-Maxwellian" EEPFs is also observed. The temperature of low energy electron group ( Tb u l k) shows significant increase with helium addition, while the temperature of tail electrons ( Tt a i l) increases smoothly as compared to ( Tb u l k).

  18. Determination of albendazole sulfoxide in human plasma by using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Saraner, Nihal; Özkan, Güler Yağmur; Güney, Berrak; Alkan, Erkin; Burul-Bozkurt, Nihan; Sağlam, Onursal; Fikirdeşici, Ezgi; Yıldırım, Mevlüt

    2016-06-01

    A rapid, simple and sensitive method was developed and validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS) for determination of albendazole sulfoxide (ABZOX) in human plasma. The plasma samples were extracted by protein precipitation using albendazole sulfoxide-d3 as internal standard (IS). The chromatographic separation was performed on Waters Xbridge C18Column (100×4.6mm, 3.5μm) with a mobile phase consisting of ammonia solution, water and methanol at a flow rate of 0.70mL/min. ABZOX was detected and identified by mass spectrometry with electrospray ionization (ESI) in positive ion and multiple-reaction monitoring (MRM) mode. The method was linear in the range of 3-1500ng/mL for ABZOX. This method was successfully applied to the bioequivalence study in human plasma samples.

  19. Neutral Beam Source and Target Plasma for Development of a Local Electric Field Fluctuation Diagnostic

    Science.gov (United States)

    Bakken, M. R.; Burke, M. G.; Fonck, R. J.; Lewicki, B. T.; Rhodes, A. T.; Winz, G. R.

    2016-10-01

    A new diagnostic measuring local E-> (r , t) fluctuations is being developed for plasma turbulence studies in tokamaks. This is accomplished by measuring fluctuations in the separation of the π components in the Hα motional Stark spectrum. Fluctuations in this separation are expected to be Ẽ / ẼEMSE 10-3EMSE 10-3 . In addition to a high throughput, high speed spectrometer, the project requires a low divergence (Ω 0 .5°) , 80 keV, 2.5 A H0 beam and a target plasma test stand. The beam employs a washer-stack arc ion source to achieve a high species fraction at full energy. Laboratory tests of the ion source demonstrate repeatable plasmas with Te 10 eV and ne 1.6 ×1017 m-3, sufficient for the beam ion optics requirements. Te and ne scalings of the ion source plasma are presented with respect to operational parameters. A novel three-phase resonant converter power supply will provide 6 mA/cm2 of 80 keV H0 at the focal plane for pulse lengths up to 15 ms, with low ripple δV / 80 keV 0.05 % at 280 kHz. Diagnostic development and validation tests will be performed on a magnetized plasma test stand with 0.5 T field. The test chamber will utilize a washer-stack arc source to produce a target plasma comparable to edge tokamak plasmas. A bias-plate with programmable power supply will be used to impose Ẽ within the target plasma. Work supported by US DOE Grant DE-FG02-89ER53296.

  20. Application of a pulsed, RF-driven, multicusp source for low energy plasma immersion ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Wengrow, A.B.; Leung, K.N.; Perkins, L.T.; Pickard, D.S.; Rickard, M.; Williams, M.D. [Lawrence Berkeley Lab., CA (United States); Tucker, M. [Spectrum Sciences, Inc., Santa Clara, CA (United States)

    1996-06-01

    The multicusp ion source can produce large volumes of uniform, quiescent, high density plasmas. A plasma chamber suited for plasma immersion ion implantation (PIII) was readily made. Conventional PIII pulses the bias voltage applied to the substrate which is immersed in a CW mode plasma. Here, a method by which the plasma itself is pulsed was developed. Typically pulse lengths of 500 {mu}s are used and are much shorter than that of the substrate voltage pulse (5-15 ms). This approach, together with low gas pressures and low bias voltages, permits the constant energy implantation of an entire wafer simultaneously without glow discharge. Results show that this process can yield implant currents of up to 2.5 mA/cm{sup 2}; thus very short implant times can be achieved. Uniformity of the ion flux is also discussed. As this method can be scaled to any dimension, it can be made to handle any size wafer.

  1. Behavior of moving plasma in solenoidal magnetic field in a laser ion source

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, S., E-mail: ikeda.s.ae@m.titech.ac.jp [Interdisciplinary Graduate School of Science and Engineering, Tokyo Institute of Technology, Yokohama, Kanagawa 226-8502 (Japan); Nishina Center for Accelerator-Based Science, RIKEN, Wako, Saitama 351-0108 (Japan); Takahashi, K. [Department of Electrical Engineering, Nagaoka University of Technology, Nagaoka, Niigata 940-2137 (Japan); Okamura, M. [Collider-Accelerator Department, Brookhaven National Laboratory, Upton, New York 11973-5000 (United States); Horioka, K. [Interdisciplinary Graduate School of Science and Engineering, Tokyo Institute of Technology, Yokohama, Kanagawa 226-8502 (Japan)

    2016-02-15

    In a laser ion source, a solenoidal magnetic field is useful to guide the plasma and to control the extracted beam current. However, the behavior of the plasma drifting in the magnetic field has not been well understood. Therefore, to investigate the behavior, we measured the plasma ion current and the total charge within a single pulse in the solenoid by changing the distance from the entrance of the solenoid to a detector. We observed that the decrease of the total charge along the distance became smaller as the magnetic field became larger and then the charge became almost constant with a certain magnetic flux density. The results indicate that the transverse spreading speed of the plasma decreased with increasing the field and the plasma was confined transversely with the magnetic flux density. We found that the reason of the confinement was not magnetization of ions but an influence induced by electrons.

  2. Behavior of moving plasma in solenoidal magnetic field in a laser ion source

    Science.gov (United States)

    Ikeda, S.; Takahashi, K.; Okamura, M.; Horioka, K.

    2016-02-01

    In a laser ion source, a solenoidal magnetic field is useful to guide the plasma and to control the extracted beam current. However, the behavior of the plasma drifting in the magnetic field has not been well understood. Therefore, to investigate the behavior, we measured the plasma ion current and the total charge within a single pulse in the solenoid by changing the distance from the entrance of the solenoid to a detector. We observed that the decrease of the total charge along the distance became smaller as the magnetic field became larger and then the charge became almost constant with a certain magnetic flux density. The results indicate that the transverse spreading speed of the plasma decreased with increasing the field and the plasma was confined transversely with the magnetic flux density. We found that the reason of the confinement was not magnetization of ions but an influence induced by electrons.

  3. The morphology of mass selected ruthenium nanoparticles from a magnetron-sputter gas-aggregation source

    DEFF Research Database (Denmark)

    Nielsen, Rasmus Munksgård; Murphy, Shane; Strebel, Christian Ejersbo

    2010-01-01

    We have investigated the morphology of mass selected ruthenium nanoparticles produced with a magnetron-sputter gas-aggregation source. The nanoparticles are mass selected using a quadrupole mass filter, resulting in narrow size distributions and average diameters between 2 and 15 nm. The particle...

  4. Determination of rutin in rat plasma by ultra performance liquid chromatography tandem mass spectrometry and application to pharmacokinetic study.

    Science.gov (United States)

    Chen, Mengchun; Zhang, Xiaoqian; Wang, Hao; Lin, Baoli; Wang, Shuanghu; Hu, Guoxin

    2015-04-01

    A sensitive and rapid ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS-MS) method for the determination of rutin in rat plasma was developed and validated. After addition of tolbutamide as internal standard (IS), protein precipitation by acetonitrile was used as sample preparation. The chromatographic separation was performed on an Acquity UPLC BEH C18 column (2.1 × 50 mm, 1.7 μm particle size), using acetonitrile-0.1% formic acid as the mobile phase with gradient elution, delivered at a flow-rate of 0.4 mL/min. Mass spectrometric analysis was performed using a XEVO TQD mass spectrometer coupled with an electro-spray ionization (ESI) source in the positive ion mode. The MRM transitions of m/z 610.91→302.98 and m/z 271.2→155.1 were used to quantify for rutin and tolbutamide, respectively. This assay method has been fully validated in terms of specificity, linearity, recovery and matrix effect, accuracy, precision and stability. Calibration curves were linear in the concentration ranges of 25-2000 ng/mL for rutin. Only 3 min was needed for an analytical run. This developed method was successfully used for determination of rutin in rat plasma for pharmacokinetic study.

  5. Methods of gas purification and effect on the ion composition in an RF atmospheric pressure plasma jet investigated by mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Grosse-Kreul, Simon; Huebner, Simon; Schneider, Simon; Keudell, Achim von; Benedikt, Jan [Ruhr-Universitaet Bochum, Institute for Experimental Physics II, Bochum (Germany)

    2016-12-15

    The analysis of the ion chemistry of atmospheric pressure plasmas is essential to evaluate ionic reaction pathways during plasma-surface or plasma-analyte interactions. In this contribution, the ion chemistry of a radio-frequency atmospheric pressure plasma jet (μ-APPJ) operated in helium is investigated by mass spectrometry (MS). It is found, that the ion composition is extremely sensitive to impurities such as N{sub 2}, O{sub 2} and H{sub 2}O. Without gas purification, protonated water cluster ions of the form H{sup +}(H{sub 2}O){sub n} are dominating downstream the positive ion mass spectrum. However, even after careful feed gas purification to the sub-ppm level using a molecular sieve trap and a liquid nitrogen trap as well as operation of the plasma in a controlled atmosphere, the positive ion mass spectrum is strongly influenced by residual trace gases. The observations support the idea that species with a low ionization energy serve as a major source of electrons in atmospheric pressure helium plasmas. Similarly, the neutral density of atomic nitrogen measured by MS in a He/N{sub 2} mixture is varying up to a factor 3, demonstrating the significant influence of impurities on the neutral species chemistry as well. (orig.)

  6. Droplet-based, high-brightness extreme ultraviolet laser plasma source for metrology

    Science.gov (United States)

    Vinokhodov, A. Yu.; Krivokorytov, M. S.; Sidelnikov, Yu. V.; Krivtsun, V. M.; Medvedev, V. V.; Koshelev, K. N.

    2016-10-01

    We report on the development of a high brightness source of extreme ultraviolet radiation (EUV) with a working wavelength of 13.5 nm. The source is based on a laser-produced plasma driven by pulsed radiation of a Nd:YAG laser system. Liquid droplets of Sn-In eutectic alloy were used as the source fuel. The droplets were created by a droplet generator operating in the jet break-up regime. The EUV emission properties of the plasma, including the emission spectrum, time profile, and conversion efficiency of laser radiation into useful 13.5 nm photons, have been characterized. Using the shadowgraphy technique, we demonstrated the production of corpuscular debris by the plasma source and the influence of the plasma on the neighboring droplet targets. The high-frequency laser operation was simulated by usage of the dual pulse regime. Based on the experimental results, we discuss the physical phenomena that could affect the source operation at high repetition rates. Finally, we estimate that an average source brightness of 1.2 kW/mm2 sr is feasible at a high repetition rate.

  7. Hard X-ray sources from miniature plasma focus devices

    Energy Technology Data Exchange (ETDEWEB)

    Raspa, V. [Buenos Aires Univ., PLADEMA, CONICET and INFIP (Argentina); Silva, P.; Moreno, J.; Zambra, M.; Soto, L. [Comision Chilena de Energia Nuclear, Santiago (Chile)

    2004-07-01

    As first stage of a program to design a repetitive pulsed radiation generator for industrial applications, two miniature plasma foci have been designed and constructed at the Chilean commission of nuclear energy. The devices operate at an energy level of the order of tens of joules (PF-50 J, 160 nF capacitor bank, 20-35 kV, 32-100 J, {approx} 150 ns time to peak current) and hundred of joules (PF-400 J, 880 nF, 20-35 kV, 176-539 J, {approx} 300 ns time to peak current). Hard X-rays are being studied in these devices operating with hydrogen. Images of metallic plates with different thickness were obtained on commercial radiographic film, Agfa Curix ST-G2, in order to characterize the energy of the hard X-ray outside of the discharge chamber of PF-400 J. An effective energy of the order of 90 keV was measured under those conditions. X ray images of different metallic objects also have been obtained. (authors)

  8. Deposition of dielectric films on silicon using a fore-vacuum plasma electron source.

    Science.gov (United States)

    Zolotukhin, D B; Oks, E M; Tyunkov, A V; Yushkov, Yu G

    2016-06-01

    We describe an experiment on the use of a fore-vacuum-pressure, plasma-cathode, electron beam source with current up to 100 mA and beam energy up to 15 keV for deposition of Mg and Al oxide films on Si substrates in an oxygen atmosphere at a pressure of 10 Pa. The metals (Al and Mg) were evaporated and ionized using the electron beam with the formation of a gas-metal beam-plasma. The plasma was deposited on the surface of Si substrates. The elemental composition of the deposited films was analyzed.

  9. Deposition of dielectric films on silicon using a fore-vacuum plasma electron source

    Energy Technology Data Exchange (ETDEWEB)

    Zolotukhin, D. B.; Tyunkov, A. V.; Yushkov, Yu. G., E-mail: yuyushkov@gmail.com [Tomsk State University of Control Systems and Radioelectronics, 40 Lenin Ave., Tomsk 634050 (Russian Federation); Oks, E. M. [Tomsk State University of Control Systems and Radioelectronics, 40 Lenin Ave., Tomsk 634050 (Russian Federation); Institute of High Current Electronics SB RAS, 2/3, Akademichesky Ave., Tomsk 634055 (Russian Federation)

    2016-06-15

    We describe an experiment on the use of a fore-vacuum-pressure, plasma-cathode, electron beam source with current up to 100 mA and beam energy up to 15 keV for deposition of Mg and Al oxide films on Si substrates in an oxygen atmosphere at a pressure of 10 Pa. The metals (Al and Mg) were evaporated and ionized using the electron beam with the formation of a gas-metal beam-plasma. The plasma was deposited on the surface of Si substrates. The elemental composition of the deposited films was analyzed.

  10. Tungsten transport and sources control in JET ITER-like wall H-mode plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Fedorczak, N., E-mail: nicolas.fedorczak@cea.fr [CEA, IRFM, F-13108 Saint-Paul-Lez-Durance (France); Monier-Garbet, P. [CEA, IRFM, F-13108 Saint-Paul-Lez-Durance (France); Pütterich, T. [MPI für Plasmaphysik, EURATOM Association, Boltzmannstrasse 2, 85748 Garching (Germany); Brezinsek, S. [Institute of Energy and Climate Research, Forschungszentrum Jlich, Assoc EURATOM-FZJ, Jlich (Germany); Devynck, P.; Dumont, R.; Goniche, M.; Joffrin, E. [CEA, IRFM, F-13108 Saint-Paul-Lez-Durance (France); Lerche, E. [Association EURATOM-Belgian State, LPP-ERM-KMS, TEC partner, Brussels (Belgium); Euratom/CCFE Fusion Association, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Lipschultz, B. [York Plasma Institute, University of York, Heslington, York YO10 5DD (United Kingdom); Luna, E. de la [Laboratorio Nacional de Fusin, Asociacin EURATOM/CIEMAT, 28040 Madrid (Spain); Maddison, G. [Culham Centre for Fusion Energy, EURATOM-CCFE Association, Abingdon (United Kingdom); Maggi, C. [MPI für Plasmaphysik, EURATOM Association, Boltzmannstrasse 2, 85748 Garching (Germany); Matthews, G. [Culham Centre for Fusion Energy, EURATOM-CCFE Association, Abingdon (United Kingdom); Nunes, I. [Istituto de plasmas e fusao nuclear, Lisboa (Portugal); Rimini, F. [Culham Centre for Fusion Energy, EURATOM-CCFE Association, Abingdon (United Kingdom); Solano, E.R. [Laboratorio Nacional de Fusin, Asociacin EURATOM/CIEMAT, 28040 Madrid (Spain); Tamain, P. [CEA, IRFM, F-13108 Saint-Paul-Lez-Durance (France); Tsalas, M. [Association EURATOM-Hellenic Republic, NCSR Demokritos 153 10, Attica (Greece); Vries, P. de [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France)

    2015-08-15

    A set of discharges performed with the JET ITER-like wall is investigated with respect to control capabilities on tungsten sources and transport. In attached divertor regimes, increasing fueling by gas puff results in higher divertor recycling ion flux, lower divertor tungsten source, higher ELM frequency and lower core plasma radiation, dominated by tungsten ions. Both pedestal flushing by ELMs and divertor screening (including redeposition) are possibly responsible. For specific scenarios, kicks in plasma vertical position can be employed to increase the ELM frequency, which results in slightly lower core radiation. The application of ion cyclotron radio frequency heating at the very center of the plasma is efficient to increase the core electron temperature gradient and flatten electron density profile, resulting in a significantly lower central tungsten peaking. Beryllium evaporation in the main chamber did not reduce the local divertor tungsten source whereas core radiation was reduced by approximately 50%.

  11. Effect of dietary protein sources on production performance, egg quality, and plasma parameters of laying hens

    Science.gov (United States)

    Wang, Xiaocui; Zhang, Haijun; Wang, Hao; Wang, Jing; Wu, Shugeng; Qi, Guanghai

    2017-01-01

    Objective This study was conducted to evaluate the effects of dietary protein sources (soybean meal, SBM; low-gossypol cottonseed meal, LCSM; double-zero rapeseed meal, DRM) on laying performance, egg quality, and plasma parameters of laying hens. Methods A total of 432 32-wk-old laying hens were randomly divided into 6 treatments with 6 replicates of 12 birds each. The birds were fed diets containing SBM, LCSM100, or DRM100 individually or in combination with an equal amount of crude protein (CP) (LCSM50, DRM50, and LCSM50-DRM50). The experimental diets, which were isocaloric (metabolizable energy, 11.11 MJ/kg) and isonitrogenous (CP, 16.5%), had similar digestible amino acid profile. The feeding trial lasted 12 weeks. Results The daily egg mass was decreased in the LCSM100 and LCSM50-DRM50 groups (p0.05) and showed increased yolk color at the end of the trial (p0.05). Conclusion Together, our results suggest that the LCSM100 or DRM100 diets may produce the adverse effects on laying performance and egg quality after feeding for 8 more weeks. The 100.0 g/kg LCSM diet or the148.7 g/kg DRM diet has no adverse effects on laying performance and egg quality. PMID:27608634

  12. A common source for neutrino and sparticle masses

    CERN Document Server

    Brignole, Andrea; Rossi, Anna

    2010-01-01

    We discuss supersymmetric scenarios in which neutrino masses arise from effective d=6 operators in the Kahler potential (including SUSY-breaking insertions). Simple explicit realizations of those Kahler operators are presented in the context of the type II seesaw. An appealing scenario emerges upon identifying the seesaw mediators with SUSY-breaking messengers.

  13. The effect of biasing the plasma electrode on hydrogen ion formations in a multicusp ion source

    Energy Technology Data Exchange (ETDEWEB)

    Ego, Hiroyasu; Iwashita, Yoshihisa (Kyoto Univ., Uji (Japan). Inst. for Chemical Research); Takekoshi, Hidekuni

    1992-03-01

    The plasma electrode covered with magnetic cusp fields acting as a magnetic filter was installed in a multicusp ion source. The formation processes of the negative and positive hydrogen ions in this source have been investigated when an electrostatic positive bias is applied to the plasma electrode with respect to the anode chamber. The dominant H[sup -] volume-production process is the recombinational attachment rather than the dissociative attachment when the bias voltage is more than +3V. This recombinational attachment improves the H[sup +] ratio in the extracted positive beam, keeping its current value. (author) 52 refs.

  14. Non-thermal atmospheric pressure HF plasma source: generation of nitric oxide and ozone for bio-medical applications

    Science.gov (United States)

    Kühn, S.; Bibinov, N.; Gesche, R.; Awakowicz, P.

    2010-01-01

    A new miniature high-frequency (HF) plasma source intended for bio-medical applications is studied using nitrogen/oxygen mixture at atmospheric pressure. This plasma source can be used as an element of a plasma source array for applications in dermatology and surgery. Nitric oxide and ozone which are produced in this plasma source are well-known agents for proliferation of the cells, inhalation therapy for newborn infants, disinfection of wounds and blood ozonation. Using optical emission spectroscopy, microphotography and numerical simulation, the gas temperature in the active plasma region and plasma parameters (electron density and electron distribution function) are determined for varied nitrogen/oxygen flows. The influence of the gas flows on the plasma conditions is studied. Ozone and nitric oxide concentrations in the effluent of the plasma source are measured using absorption spectroscopy and electro-chemical NO-detector at variable gas flows. Correlations between plasma parameters and concentrations of the particles in the effluent of the plasma source are discussed. By varying the gas flows, the HF plasma source can be optimized for nitric oxide or ozone production. Maximum concentrations of 2750 ppm and 400 ppm of NO and O3, correspondingly, are generated.

  15. Development of plasma sources for ICRF heating experiment in KMAX mirror device

    Science.gov (United States)

    Sun, Xuan; Liu, Ming; Yi, Hongshen; Lin, Munan; Shi, Peiyun

    2016-10-01

    KMAX, Keda Mirror with AXisymmeticity, is a tandem mirror machine with a length of 10 meters and diameters of 1.2 meters in the central cell and 0.3 meters in the mirror throat. In the past experiments, the plasma was generated by helicon wave launched from the west end. We obtained the blue core mode in argon discharge, however, it cannot provide sufficient plasma for hydrogen discharge, which is at least 1012 cm-3 required for effective ICRF heating. Several attempts have thus been tried or under design to increase the central cell's plasma density: (1) a washer gun with aperture of 1cm has been successfully tested, and a plasma density of 1013 cm-3 was achieved in the west cell near the gun, however, the plasma is only 1011 cm-3 in the central cell possible due to the mirror trapping and/or neutral quenching effect (2) a larger washer gun with aperture of 2.5 cm and a higher power capacitor bank are being assembled in order to generate more plasmas. In addition, how to mitigate the neutrals is under consideration (3) A hot cathode is been designed and will be tested in combination with plasma gun or alone. Preliminary results from those plasma sources will be presented and discussed.

  16. Characteristics of cold atmospheric plasma source based on low-current pulsed discharge with coaxial electrodes

    Science.gov (United States)

    Bureyev, O. A.; Surkov, Yu S.; Spirina, A. V.

    2017-05-01

    This work investigates the characteristics of the gas discharge system used to create an atmospheric pressure plasma flow. The plasma jet design with a cylindrical graphite cathode and an anode rod located on the axis of the system allows to realize regularly reproducible spark breakdowns mode with a frequency ∼ 5 kHz and a duration ∼ 40 μs. The device generates a cold atmospheric plasma flame with 1 cm in diameter in the flow of various plasma forming gases including nitrogen and air at about 100 mA average discharge current. In the described construction the cathode spots of individual spark channels randomly move along the inner surface of the graphite electrode creating the secondary plasma stream time-average distributed throughout the whole exit aperture area after the decay of numerous filamentary discharge channels. The results of the spectral diagnostics of plasma in the discharge gap and in the stream coming out of the source are presented. Despite the low temperature of atoms and molecules in plasma stream the cathode spots operation with temperature of ∼ 4000 °C at a graphite electrode inside a discharge system enables to saturate the plasma by CN-radicals and atomic carbon in the case of using nitrogen as the working gas.

  17. Comparison of dielectric barrier discharge, atmospheric pressure radiofrequency-driven glow discharge and direct analysis in real time sources for ambient mass spectrometry of acetaminophen

    Energy Technology Data Exchange (ETDEWEB)

    Kratzer, Jan [Institute for National Measurement Standards, National Research Council of Canada, 1200 Montreal Road, Ottawa, Ontario, K1A 0R6 (Canada); Institute of Analytical Chemistry of the ASCR, v.v.i., Veveri 97, CZ-602 00 Brno (Czech Republic); Mester, Zoltan [Institute for National Measurement Standards, National Research Council of Canada, 1200 Montreal Road, Ottawa, Ontario, K1A 0R6 (Canada); Sturgeon, Ralph E., E-mail: Ralph.Sturgeon@nrc-cnrc.gc.ca [Institute for National Measurement Standards, National Research Council of Canada, 1200 Montreal Road, Ottawa, Ontario, K1A 0R6 (Canada)

    2011-08-15

    Three plasma-based ambient pressure ion sources were investigated; laboratory constructed dielectric barrier and rf glow discharges, as well as a commercial corona discharge (DART source). All were used to desorb and ionize a model analyte, providing sampling techniques for ambient mass spectrometry (MS). Experimental parameters were optimized to achive highest signal for acetaminophen as the analyte. Insight into the mechanisms of analyte desorption and ionization was obtained by means of emission spectrometry and ion current measurements. Desorption and ionization mechanisms for this analyte appear to be identical for all three plasma sources. Emission spectra differ only in the intensities of various lines and bands. Desorption of solid analyte requires transfer of thermal energy from the plasma source to sample surface, in the absence of which complete loss of MS response occurs. For acetaminophen, helium was the best plasma gas, providing 100- to 1000-fold higher analyte response than with argon or nitrogen. The same trend was also evident with background ions (protonated water clusters). MS analyte signal intensity correlates with the ion density (expressed as ion current) in the plasma plume and with emission intensity from excited state species in the plasma. These observations support an ionization process which occurs via proton transfer from protonated water clusters to analyte molecules.

  18. A LASER ION-SOURCE FOR ONLINE MASS SEPARATION

    NARCIS (Netherlands)

    VANDUPPEN, P; DENDOOVEN, P; HUYSE, M; VERMEEREN, L; QAMHIEH, ZN; SILVERANS, RE; VANDEWEERT, E

    1992-01-01

    A laser ion source based on resonance photo ionization in a gas cell is proposed. The gas cell, filled with helium, consists of a target chamber in which the recoil products are stopped and neutralized, and an ionization chamber where the atoms of interest are selectively ionized by the laser light.

  19. Mass Quadrupole as a Source of Naked Singularities

    CERN Document Server

    Quevedo, Hernando

    2010-01-01

    We investigate the gravitational field of a static mass with quadrupole moment in empty space. It is shown that in general this configuration is characterized by the presence of curvature singularities without a surrounding event horizon. These naked singularities generate an effective field of repulsive gravity which, in turn, drastically changes the behavior of test particles. As a possible consequence, the accretion disk around a naked singularity presents a particular discontinuous structure.

  20. Inductively coupled plasma mass spectrometry in the analysis of biological samples and pharmaceutical drugs

    Science.gov (United States)

    Ossipov, K.; Seregina, I. F.; Bolshov, M. A.

    2016-04-01

    Inductively coupled plasma mass spectrometry (ICP-MS) is widely used in the analysis of biological samples (whole blood, serum, blood plasma, urine, tissues, etc.) and pharmaceutical drugs. The shortcomings of this method related to spectral and non-spectral interferences are manifested in full measure in determination of the target analytes in these complex samples strongly differing in composition. The spectral interferences are caused by similarity of masses of the target component and sample matrix components. Non-spectral interferences are related to the influence of sample matrix components on the physicochemical processes taking place during formation and transportation of liquid sample aerosols into the plasma, on the value and spatial distribution of plasma temperature and on the transmission of the ion beam from the interface to mass spectrometer detector. The review is devoted to analysis of different mechanisms of appearance of non-spectral interferences and to ways for their minimization or elimination. Special attention is paid to the techniques of biological sample preparation, which largely determine the mechanisms of the influence of sample composition on the results of element determination. The ways of lowering non-spectral interferences by instrumental parameter tuning and application of internal standards are considered. The bibliography includes 189 references.

  1. Studies of extreme ultraviolet emission from laser produced plasmas, as sources for next generation lithography

    Science.gov (United States)

    Cummins, Thomas

    The work presented in this thesis is primarily concerned with the optimisation of extreme ultraviolet (EUV) photoemission around 13.5 nm, from laser produced tin (Sn) plasmas. EUV lithography has been identified as the leading next generation technology to take over from the current optical lithography systems, due to its potential of printing smaller feature sizes on integrated circuits. Many of the problems hindering the implementation of EUV lithography for high volume manufacturing have been overcome during the past 20 years of development. However, the lack of source power is a major concern for realising EUV lithography and remains a major roadblock that must be overcome. Therefore in order to optimise and improve the EUV emission from Sn laser plasma sources, many parameters contributing to the make-up of an EUV source are investigated. Chapter 3 presents the results of varying several different experimental parameters on the EUV emission from Sn laser plasmas. Several of the laser parameters including the energy, gas mixture, focusing lens position and angle of incidence are changed, while their effect on the EUV emission is studied. Double laser pulse experiments are also carried out by creating plasma targets for the main laser pulse to interact with. The resulting emission is compared to that of a single laser pulse on solid Sn. Chapter 4 investigates tailoring the CO2 laser pulse duration to improve the efficiency of an EUV source set-up. In doing so a new technique for shortening the time duration of the pulse is described. The direct effects of shortening the CO2 laser pulse duration on the EUV emission from Sn are then studied and shown to improve the efficiency of the source. In Chapter 5 a new plasma target type is studied and compared to the previous dual laser experiments. Laser produced colliding plasma jet targets form a new plasma layer, with densities that can be optimised for re-heating with the main CO2 laser pulse. Chapter 6 will present

  2. Atomic processes and equation of state of high Z plasmas for EUV sources and their effects on the spatial and temporal evolution of the plasmas

    Science.gov (United States)

    Sasaki, Akira; Sunahara, Atushi; Furukawa, Hiroyuki; Nishihara, Katsunobu; Nishikawa, Takeshi; Koike, Fumihiro

    2016-03-01

    Laser-produced plasma (LPP) extreme ultraviolet (EUV) light sources have been intensively investigated due to potential application to next-generation semiconductor technology. Current studies focus on the atomic processes and hydrodynamics of plasmas to develop shorter wavelength sources at λ = 6.x nm as well as to improve the conversion efficiency (CE) of λ = 13.5 nm sources. This paper examines the atomic processes of mid-z elements, which are potential candidates for λ = 6.x nm source using n=3-3 transitions. Furthermore, a method to calculate the hydrodynamics of the plasmas in terms of the initial interaction between a relatively weak prepulse laser is presented.

  3. Liquid chromatography-mass spectrometric determination of rufinamide in low volume plasma samples.

    Science.gov (United States)

    Gáll, Zsolt; Vancea, Szende; Dogaru, Maria T; Szilágyi, Tibor

    2013-12-01

    Quantification of rufinamide in plasma was achieved using a selective and sensitive liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) method. The chromatographic separation was achieved on a reversed phase column (Zorbax SB-C18 100mm×3mm, 3.5μm) under isocratic conditions. The mobile phase consisted of a mixture of water containing 0.1% formic acid and methanol (50:50, v/v). The mass spectrometric detection of the analyte was in multiple reaction monitoring mode (MRM) using an electrospray positive ionization (ESI positive). The monitored ions were 127m/z derived from 239m/z rufinamide and 108m/z derived from 251m/z the internal standard (lacosamide). Protein precipitation with methanol was applied for sample preparation using only 50μl aliquots. The concentration range was 40-2000ng/ml for rufinamide in plasma. The limit of detection was 1.25ng/ml and the lower limit of quantification was established at 5ng/ml rufinamide concentration. Selectivity and matrix effect was verified using individual human, rat and rabbit plasma samples. Short-term, post-preparative and freeze-thaw stability was also investigated. The proposed method provides accuracy, precision and high-throughput (short runtime 4.5min) for quantitative determination of rufinamide in plasma. This is the first reported liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for analysis of rufinamide from low volume plasma samples. The LC-MS/MS method was validated according to the current official guidelines and can be applied to accurately measure rufinamide level of large number of plasma samples from clinical studies or therapeutic drug monitoring.

  4. Mass conservation for instantaneous sources in FEM3 simulations of material dispersion

    Energy Technology Data Exchange (ETDEWEB)

    Rodean, H.C.

    1987-11-01

    This report presents the results of a systematic study in which it is shown that the numerical integration errors in determining material mass content are negligible; the material phase-change model by itself is not a cause of material mass variation; and a linear relation between fractional mass change and fractional density change at the source center for given mesh and source geometries exists over a range of values from 10/sup -5/ to 10/sup -1/. This suggests that the omission of the par. delta rho/par. deltat term from the mass conservation equation is the cause of the observed non-conservation of mass by FEM3. It is shown that these mass variations can be minimized by minimizing the initial density gradients in the source region. 5 refs., 18 figs., 4 tabs.

  5. Inductively coupled plasma mass spectrometry for stable isotope metabolic tracer studies of living systems

    Energy Technology Data Exchange (ETDEWEB)

    Luong, Elise [Iowa State Univ., Ames, IA (United States)

    1999-05-10

    This dissertation focuses on the development of methods for stable isotope metabolic tracer studies in living systems using inductively coupled plasma single and dual quadrupole mass spectrometers. Sub-nanogram per gram levels of molybdenum (Mo) from human blood plasma are isolated by the use of anion exchange alumina microcolumns. Million-fold more concentrated spectral and matrix interferences such as sodium, chloride, sulfate, phosphate, etc. in the blood constituents are removed from the analyte. The recovery of Mo from the alumina column is 82 ± 5% (n = 5). Isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) is utilized for the quantitative ultra-trace concentration determination of Mo in bovine and human blood samples. The average Mo concentration in reference bovine serum determined by this method is 10.2 ± 0.4 ng/g, while the certified value is 11.5 ± 1.1 ng/g (95% confidence interval). The Mo concentration of one pool of human blood plasma from two healthy male donors is 0.5 ± 0.1 ng/g. The inductively coupled plasma twin quadrupole mass spectrometer (ICP-TQMS) is used to measure the carbon isotope ratio from non-volatile organic compounds and bio-organic molecules to assess the ability as an alternative analytical method to gas chromatography combustion isotope ratio mass spectrometry (GC-combustion-IRMS). Trytophan, myoglobin, and β-cyclodextrin are chosen for the study, initial observation of spectral interference of 13C+ with 12C 1H+ comes from the incomplete dissociation of myoglobin and/or β-cyclodextrin.

  6. Enhancement of H{sup -}/D{sup -} volume production in a double plasma type negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Fukumasa, Osamu; Nishimura, Hideki; Sakiyama, Satoshi [Yamaguchi Univ., Ube (Japan). Faculty of Engineering

    1997-02-01

    H{sup -}/D{sup -} production in a pure volume source has been studied. In our double plasma type negative ion source, both energy and density of fast electrons are well controlled. With the use of this source, the enhancement of H{sup -}/D{sup -} production has been observed. Namely, under the same discharge power, the extracted H{sup -}/D{sup -} current in the double plasma operation is higher than that in the single plasma operation. At the same time, measurements of plasma parameters have been made in the source and the extractor regions for these two cases. (author)

  7. Chemotherapy and information-seeking behaviour: characteristics of patients using mass-media information sources.

    Science.gov (United States)

    Muusses, Linda D; van Weert, Julia C M; van Dulmen, Sandra; Jansen, Jesse

    2012-09-01

    Fulfilling patients' information needs can help them cope with illness and improve their well-being. Little research has been conducted on the characteristics of patients using different information sources. This study aims to get insight into which information sources patients receiving chemotherapy for the first time use and which factors (background characteristics, psychological factors, information needs and source reliability) explain the use of different mass-media information sources. Three hundred forty-five patients receiving chemotherapy in ten hospitals in the Netherlands completed a questionnaire. Use of 16 sources (mass-media and interpersonal) was measured with a five-point Likert scale. Regression analyses were conducted to test whether use of the three most frequently used mass-media sources could be explained by socio-demographic, medical and psychological factors, unfulfilled information needs and perceived reliability of the source. Treatment guide, brochures and Internet were the most frequently used mass-media sources. Medical specialists, nurses, and family and/or friends were the most common interpersonal sources. Using the treatment guide was found to be associated with treatment goal, unfulfilled information needs and source reliability. Using brochures was associated with cancer-related stress responses, coping style and source reliability. Using Internet was associated with age, education, coping style and source reliability. This study developed a model to explain the use of mass-media information sources by patients with cancer receiving chemotherapy. The use of different information sources is associated with different factors, indicating that each source offers specific opportunities to tailor information to the patient's needs. Copyright © 2011 John Wiley & Sons, Ltd. Copyright © 2011 John Wiley & Sons, Ltd.

  8. Optical diagnostics and mass spectrometry on the afterglow of an atmospheric pressure Ar/O$_2$ radiofrequency plasma used for polymer surface treatment

    CERN Document Server

    Duluard, Corinne Y; Hubert, Julie; Reniers, François

    2016-01-01

    In the context of polymer surface treatment, the afterglow of an atmospheric pressure Ar/O$_2$ radiofrequency plasma is characterized by optical emission spectroscopy, laser induced fluorescence and mass spectrometry. The influence of the O$_2$ gas flow rate and the source power on the plasma properties (gas temperature, Ar excitation temperature, relative concentrations of O atoms and OH radicals) are evaluated. We show that for plasma torch-to-substrate distances lower than 6 mm, the afterglow creates a protective atmosphere, thus the plasma gas composition interacting with the substrate is well controlled. For higher distances, the influence of ambient air can no longer be neglected and gradients in Ar, O$_2$ and N$_2$ concentrations are measured as a function of axial and vertical position.

  9. Narrow bandwidth Thomson photon source development using Laser-Plasma Accelerators

    Science.gov (United States)

    Geddes, C. G. R.; van Tilborg, J.; Tsai, H.-E.; Toth, Cs.; Vay, J.-L.; Lehe, R.; Schroeder, C. B.; Esarey, E.; Rykovanov, S. G.; Grote, D. P.; Friedman, A.; Leemans, W. P.

    2016-10-01

    Compact, high-quality photon sources at MeV energies are being developed based on Laser-Plasma Accelerators (LPAs). An independent scattering laser with controlled pulse shaping in frequency and amplitude can be used together with laser guiding to realize high photon yield and narrow bandwidth. Simulations are presented on production of controllable narrow bandwidth sources using the beam and plasma capabilities of LPAs. Recent experiments and simulations demonstrate controllable LPAs in the energy range appropriate to MeV Thomson sources. Design of experiments and laser capabilities to combine these elements will be presented, towards a compact photon source system. A dedicated facility under construction will be described. Work supported by US DOE NNSA DNN R&D and by Sc. HEP under contract DE-AC02-05CH11231.

  10. Plasma breakdown diagnostics with the biased disc of electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Tarvainen, O; Ropponen, T; Toivanen, V; Arje, J; Koivisto, H [University of Jyvaeskylae, Department of Physics, Accelerator Laboratory, PO Box 35 (YFL), 40500 Jyvaeskylae (Finland)], E-mail: olli.tarvainen@jyu.fi

    2009-08-15

    The electron cyclotron resonance ion sources at the JYFL (University of Jyvaeskylae, Department of Physics) accelerator laboratory have been operated in pulsed mode to study the time-resolved current signal from the biased discs of the ion sources. The purpose of the experiments is to gain an understanding of the ion source parameters affecting the time required for the transition from neutral gas to plasma. It was observed that the plasma breakdown time depends strongly on the neutral gas density, gas species and density of seed electrons. In particular, it was observed that a low power microwave signal at secondary frequency makes the breakdown time virtually independent of the neutral gas density. The results can be utilized for operation of ECR ion sources in the so-called preglow mode. A simple qualitative model, which is in good agreement with the experiments, has been developed to interpret the results.

  11. Measurement of the 135Cs half-life with accelerator mass spectrometry and inductively coupled plasma mass spectrometry

    Science.gov (United States)

    MacDonald, C. M.; Cornett, R. J.; Charles, C. R. J.; Zhao, X. L.; Kieser, W. E.

    2016-01-01

    The isotope 135Cs is quoted as having a half-life of 2.3 Myr. However, there are three published values ranging from 1.8 to 3 Myr. This research reviews previous measurements and reports a new measurement of the half-life using newly developed accelerator mass spectrometry (AMS) and inductively coupled plasma mass spectrometry (ICPMS) techniques along with β and γ radiometric analysis. The half-life was determined to be (1.6 ±0.6 ) ×106 yr by AMS and (1.3 ±0.2 ) ×106 yr by ICPMS with 95% confidence. The two values agree with each other but differ from the accepted value by ˜40 % .

  12. Identification of phosphorylated butyrylcholinesterase in human plasma using immunoaffinity purification and mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Aryal, Uma K.; Lin, Chiann Tso; Kim, Jong Seo; Heibeck, Tyler H.; Wang, Jun; Qian, Weijun; Lin, Yuehe

    2012-04-20

    Paraoxon (diethyl 4-nitrophenyl phosphate) is an active metabolite of the common insecticide parathion and is acutely toxic due to the inhibition of cholinesterase (ChE) activity in the nervous systems. The Inhibition of butyrylcholinesterase (BChE) activity by paraoxon is due to the formation of phosphorylated BChE adduct, and the detection of the phosphorylated BChE adduct in human plasma can serve as an exposure biomarker of organophosphate pesticides and nerve agents. In this study, we performed immunoaffinity purification and liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis for identifying phosphorylated BChE in human plasma treated by paraoxon. BChE was captured by biotinylated anti-BChE polyclonal antibodies conjugated to streptavidin magnetic beads. Western blot analysis showed that the antibody was effective to recognize both native and modified BChE with high specificity. The exact phosphorylation site of BChE was confirmed on Serine 198 by MS/MS with a 108 Da modification mass and accurately measured parent ion masses. The phosphorylated BChE peptide was also successfully detected in the immunoaffinity purified sample from paraoxon treated human plasma. Thus, immunoaffinity purification combined with mass spectrometry represents a viable approach for the detection of paraoxon-modified BChE and other forms of modified BChE as exposure biomarkers of organophosphates and nerve agents.

  13. Application of atmospheric plasma sources in growth and differentiation of plant and mammalian stem cells

    Science.gov (United States)

    Puac, Nevena

    2014-10-01

    The expansion of the plasma medicine and its demand for in-vivo treatments resulted in fast development of various plasma devices that operate at atmospheric pressure. These sources have to fulfill all demands for application on biological samples. One of the sources that meet all the requirements needed for treatment of biological material is plasma needle. Previously, we have used this device for sterilization of planctonic samples of bacteria, MRSA biofilm, for improved differentiation of human periodontal stem cells into osteogenic line and for treatment of plant meristematic cells. It is well known that plasma generates reactive oxygen species (ROS) and reactive nitrogen species (RNS) that strongly affect metabolism of living cells. One of the open issues is to correlate external plasma products (electrons, ions, RNS, ROS, photons, strong fields etc.) with the immediate internal response which triggers or induces effects in the living cell. For that purpose we have studied the kinetics of enzymes which are typical indicators of the identity of reactive species from the plasma created environment that can trigger signal transduction in the cell and ensue cell activity. In collaboration with Suzana Zivkovicm, Institute for Biological Research ``Sinisa Stankovic,'' University of Belgrade; Nenad Selakovic, Institute of Physics, University of Belgrade; Milica Milutinovic, Jelena Boljevic, Institute for Biological Research ``Sinisa Stankovic,'' University of Belgrade; and Gordana Malovic, Zoran Lj. Petrovic, Institute of Physics, University of Belgrade. Grants III41011, ON171037 and ON173024, MESTD, Serbia.

  14. Characterization of the seminal plasma proteome in men with prostatitis by mass spectrometry

    Directory of Open Access Journals (Sweden)

    Kagedan Daniel

    2012-02-01

    Full Text Available Abstract Background Prostatitis is an inflammation of the prostate gland which affects approximately 10% of men. Despite its frequency, diagnosing prostatitis and monitoring patient response to treatment remains frustrating. As the prostate contributes a substantial percentage of proteins to seminal plasma, we hypothesized that a protein biomarker of prostatitis might be found by comparing the seminal plasma proteome of patients with and without prostatitis. Results Using mass spectrometry, we identified 1708 proteins in the pooled seminal plasma of 5 prostatitis patients. Comparing this list to a previously published list of seminal plasma proteins in the pooled seminal plasma of 5 healthy, fertile controls yielded 1464 proteins in common, 413 found only in the control group, and 254 found only in the prostatitis group. Applying a set of criteria to this dataset, we generated a high-confidence list of 59 candidate prostatitis biomarkers, 33 of which were significantly increased in prostatitis as compared to control, and 26 of which were decreased. The candidates were analyzed using Gene Ontology and Ingenuity Pathway analysis to delineate their subcellular localizations and functions. Conclusions Thus, in this study, we identified 59 putative biomarkers in seminal plasma that need further validation for diagnosis and monitoring of prostatitis.

  15. Atomic Layer Deposition Al2O3 Thin Films in Magnetized Radio Frequency Plasma Source

    Science.gov (United States)

    Li, Xingcun; Chen, Qiang; Sang, Lijun; Yang, Lizhen; Liu, Zhongwei; Wang, Zhenduo

    Self-limiting deposition of aluminum oxide (Al2O3) thin films were accomplished by the plasma-enhanced chemical vapor deposition using trimethyl aluminum (TMA) and O2 as precursor and oxidant, respectively, where argon was kept flowing in whole deposition process as discharge and purge gas. In here we present a novel plasma source for the atomic layer deposition technology, magnetized radio frequency (RF) plasma. Difference from the commercial RF source, magnetic coils were amounted above the RF electrode, and the influence of the magnetic field strength on the deposition rate and morphology are investigated in detail. It concludes that a more than 3 Å/ purging cycle deposition rate and the good quality of ALD Al2O3 were achieved in this plasma source even without extra heating. The ultra-thin films were characterized by including Fourier transform infrared (FTIR) spectroscopy, X-ray photoelectric spectroscopy (XPS), scanning electron microscopy (SEM), and atomic force microscopy (AFM). The high deposition rates obtained at ambient temperatures were analyzed after in-situ the diagnostic of plasmas by Langmuir probe.

  16. A Mirror-like ECR Plasma Source for Ionosphere Environment Simulator

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A compact mirror-like ECR (electron cyclotron resonance) plasma source for the ionosphere environment simulator was described for the first time in China. The overall sources system was composed of a 200 W 2.45 GHz microwave source, a coaxial 3λo/4 TEM-mode microwave resonance applicator, column and cylindrical Nd-Fe-P magnets, a quartz bell-shaped discharge chamber, a gas inlet system and a plasma-diffusing bore. The preliminary experiment demonstrated that ambi-polar diffusion plasma stream into the simulator (~500 mm long) formed an environment with following parameters: a plasma density ne of 104 cm-3 ~ 106cm-3, an electron temperature Te < 5 eV at a pressure P of 10-1 Pa~10-3 Pa, a plasma uniformity of > 80% over the experimental target with a 160-mm-in-diameter, satisfying primarily the requirement of simulating in a severe ionosphere environment.

  17. Studies of plasma breakdown and electron heating on a 14 GHz ECR ion source through measurement of plasma bremsstrahlung

    Energy Technology Data Exchange (ETDEWEB)

    Ropponen, T; Machicoane, G; Leitner, D [National Superconducting Cyclotron Laboratory, MSU, East Lansing, MI 48824 (United States); Tarvainen, O; Toivanen, V; Koivisto, H; Kalvas, T; Peura, P; Jones, P [University of Jyvaeskylae, Department of Physics, PO Box 35 (YFL), 40500 Jyvaeskylae (Finland); Izotov, I; Skalyga, V; Zorin, V [Institute of Applied Physics, RAS, 46 Ulyanov St., 603950 Nizhny Novgorod (Russian Federation); Noland, J, E-mail: tommi.ropponen@gmail.com, E-mail: olli.tarvainen@jyu.fi [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States)

    2011-10-15

    Temporal evolution of plasma bremsstrahlung emitted by a 14 GHz electron cyclotron resonance ion source (ECRIS) operated in pulsed mode is presented in the energy range 1.5-400 keV with 100 {mu}s resolution. Such a high temporal resolution together with this energy range has never been measured before with an ECRIS. Data are presented as a function of microwave power, neutral gas pressure, magnetic field configuration and seed electron density. The saturation time of the bremsstrahlung count rate is almost independent of the photon energy up to 100 keV and exhibits similar characteristics with the neutral gas balance. The average photon energy during the plasma breakdown is significantly higher than that during the steady state and depends strongly on the density of seed electrons. The results are consistent with a theoretical model describing the evolution of the electron energy distribution function during the preglow transient.

  18. Hydrogen Ionic Plasma and Particle Dynamics in Negative Ion Source for NBI

    Science.gov (United States)

    Tsumori, Katsuyoshi

    2013-10-01

    Three negative-ion-based neutral beam injectors (NBIs) have been developed for plasma heating in the Large Helical Device. The NBIs achieve successfully the nominal injection power and beam energy, and understanding of the production and transport mechanisms of H- ion is required to obtain more stable high power beam. In the ion source development, we have found hydrogen ionic plasmas with extremely low electron density are produced in the beam extraction region. The plasma is measured with a combination of an electrostatic probe, millimeter-wave interferometer and cavity ring down (CRD). It has been observed for the first time that the charge neutrality of the ionic plasma is broken with H- extraction and electrons compensate the extracted H- charge. The influence of the extraction field widely affects to the ionic plasma in the extraction region. Two-dimensional particle-in-cell simulation (2D-PIC) has been applied to investigate the particle transport and reproduces the production of the ionic plasma and electron compensation due to H- extraction. In particle model, produced H- ions leave from the Cs covered PG surface in opposite direction to beam extraction. The direction can be changed with the electric field and collective effect due to the presence of plasma. A new technique using CCD camera with H α filter applied to measure the two-dimensional distribution of H- density. In the ionic plasma, H α light is emitted via electron-impact excitation and mutual neutralization processes with H- ion and proton. Comparing the results obtained with optical emission spectroscopy, electrostatic probe and CRD, it is shown the H α emission is dominated with the mutual neutralization. By subtracting the CCD images with and without beam extraction, it becomes clear that H- ions are extracted not directly from the PG surface but from the bulk of the ionic plasma. The result suggests the initial energy of H- ion is dumped rapidly in the ionic plasma.

  19. Direct and Sensitive Detection of CWA Simulants by Active Capillary Plasma Ionization Coupled to a Handheld Ion Trap Mass Spectrometer

    Science.gov (United States)

    Wolf, Jan-Christoph; Etter, Raphael; Schaer, Martin; Siegenthaler, Peter; Zenobi, Renato

    2016-07-01

    An active capillary plasma ionization (ACI) source was coupled to a handheld mass spectrometer (Mini 10.5; Aston Labs, West Lafayette, IN, USA) and applied to the direct gas-phase detection and quantification of chemical warfare agent (CWA) related chemicals. Complementing the discontinuous atmospheric pressure interface (DAPI) of the Mini 10.5 mass spectrometer with an additional membrane pump, a quasi-continuous sample introduction through the ACI source was achieved. Nerve agent simulants (three dialkyl alkylphosphonates, a dialkyl phosporamidate, and the pesticide dichlorvos) were detected at low gas-phase concentrations with limits of detection ranging from 1.0 μg/m3 to 6.3 μg/m3. Our results demonstrate a sensitivity enhancement for portable MS-instrumentation by using an ACI source, enabling direct, quantitative measurements of volatile organic compounds. Due to its high sensitivity, selectivity, low power consumption (<80 W) and weight (<13 kg), this instrumentation has the potential for direct on-site CWA detection as required by military or civil protection.

  20. Direct and Sensitive Detection of CWA Simulants by Active Capillary Plasma Ionization Coupled to a Handheld Ion Trap Mass Spectrometer.

    Science.gov (United States)

    Wolf, Jan-Christoph; Etter, Raphael; Schaer, Martin; Siegenthaler, Peter; Zenobi, Renato

    2016-07-01

    An active capillary plasma ionization (ACI) source was coupled to a handheld mass spectrometer (Mini 10.5; Aston Labs, West Lafayette, IN, USA) and applied to the direct gas-phase detection and quantification of chemical warfare agent (CWA) related chemicals. Complementing the discontinuous atmospheric pressure interface (DAPI) of the Mini 10.5 mass spectrometer with an additional membrane pump, a quasi-continuous sample introduction through the ACI source was achieved. Nerve agent simulants (three dialkyl alkylphosphonates, a dialkyl phosporamidate, and the pesticide dichlorvos) were detected at low gas-phase concentrations with limits of detection ranging from 1.0 μg/m(3) to 6.3 μg/m(3). Our results demonstrate a sensitivity enhancement for portable MS-instrumentation by using an ACI source, enabling direct, quantitative measurements of volatile organic compounds. Due to its high sensitivity, selectivity, low power consumption (<80 W) and weight (<13 kg), this instrumentation has the potential for direct on-site CWA detection as required by military or civil protection. Graphical Abstract ᅟ.

  1. A mass of less than 15 solar masses for the black hole in an ultraluminous X-ray source.

    Science.gov (United States)

    Motch, C; Pakull, M W; Soria, R; Grisé, F; Pietrzyński, G

    2014-10-01

    Most ultraluminous X-ray sources have a typical set of properties not seen in Galactic stellar-mass black holes. They have luminosities of more than 3 × 10(39) ergs per second, unusually soft X-ray components (with a typical temperature of less than about 0.3 kiloelectronvolts) and a characteristic downturn in their spectra above about 5 kiloelectronvolts. Such puzzling properties have been interpreted either as evidence of intermediate-mass black holes or as emission from stellar-mass black holes accreting above their Eddington limit, analogous to some Galactic black holes at peak luminosity. Recently, a very soft X-ray spectrum was observed in a rare and transient stellar-mass black hole. Here we report that the X-ray source P13 in the galaxy NGC 7793 is in a binary system with a period of about 64 days and exhibits all three canonical properties of ultraluminous sources. By modelling the strong optical and ultraviolet modulations arising from X-ray heating of the B9Ia donor star, we constrain the black hole mass to be less than 15 solar masses. Our results demonstrate that in P13, soft thermal emission and spectral curvature are indeed signatures of supercritical accretion. By analogy, ultraluminous X-ray sources with similar X-ray spectra and luminosities of up to a few times 10(40) ergs per second can be explained by supercritical accretion onto massive stellar-mass black holes.

  2. [Experimental investigation of laser plasma soft X-ray source with gas target].

    Science.gov (United States)

    Ni, Qi-liang; Gong, Yan; Lin, Jing-quan; Chen, Bo; Cao, Jian-lin

    2003-02-01

    This paper describes a debris-free laser plasma soft X-ray source with a gas target, which has high operating frequency and can produce strong soft X-ray radiation. The valve of this light source is drived by a piezoelectrical ceramic whose operating frequency is up to 400 Hz. In comparison with laser plasma soft X-ray sources using metal target, the light source is debris-free. And it has higher operating frequency than gas target soft X-ray sources whose nozzle is controlled by a solenoid valve. A channel electron multiplier (CEM) operating in analog mode is used to detect the soft X-ray generated by the laser plasma source, and the CEM's output is fed to to a charge-sensitive preamplifier for further amplification purpose. Output charges from the CEM are proportional to the amplitude of the preamplifier's output voltage. Spectra of CO2, Xe and Kr at 8-14 nm wavelength which can be used for soft X-ray projection lithography are measured. The spectrum for CO2 consists of separate spectral lines originate mainly from the transitions in Li-like and Be-like ions. The Xe spectrum originating mainly from 4d-5f, 4d-4f, 4d-6p and 4d-5p transitions in multiply charged xenon ions. The spectrum for Kr consists of separate spectral lines and continuous broad spectra originating mainly from the transitions in Cu-, Ni-, Co- and Fe-like ions.

  3. Diagnostics of plasma decay and afterglow transient of an electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Tarvainen, O; Ropponen, T; Toivanen, V; Kalvas, T; Arje, J; Koivisto, H, E-mail: olli.tarvainen@jyu.f [University of Jyvaeskylae, Department of Physics, Accelerator Laboratory PO Box 35 (YFL), 40500 Jyvaeskylae (Finland)

    2010-08-15

    The electron cyclotron resonance ion sources at the JYFL (University of Jyvaeskylae, Department of Physics) accelerator laboratory have been operated in pulsed mode to study the decay of bremsstrahlung emission and ion beam currents of different charge states. The purpose of the experiments is to gain understanding on the ion source parameters affecting the afterglow. It was observed that the bremsstrahlung emission characteristics during the afterglow and decay times of extracted ion beam currents are virtually independent of the ion source tuning parameters. The decay time of different charge states was found to be almost inversely proportional to the square of the ion charge. The result is in good agreement with a simple theoretical model based on diffusion of ions from the magnetic field of the ion source. It was observed that the plasma decay time is shorter in the case of the ion source with lower operation frequency and, thus, lower magnetic field strength. The scaling between the ion sources supports a model based on Bohm diffusion, arising from non-linear effects such as instabilities and fluctuating fields in turbulent plasma. The experiments provide information on the mechanisms causing instabilities during the plasma decay.

  4. The effect of plasma operating parameters on analyte signals in inductively coupled plasma-mass spectrometry

    Science.gov (United States)

    Horlick, G.; Tan, S. H.; Vaughan, M. A.; Rose, C. A.

    Utilizing the SCIEX ICP-MS an extensive study of the effects that plasma operating parameters have on analyte ion signals in ICP-MS has been carried out. Parameters studied included aerosol flow rate (nebulizer pressure), auxiliary flow rate, power and sampling depth (sampling position from the load coil). The two key parameters are aerosol flow rate (nebulizer pressure) and power. Elements can be grouped into characteristic behaviour patterns based on the overall dependence of their ion count signal on these two parameters. The nebulizer pressure-power behavior patterns allow a sensible selection of compromise operating conditions and significantly clarify single parameter observations which often indicate confusing trends in behavior. In addition to characterizing analyte ion signals the parameter behavior plots have also been used to study oxide species and plus two ions in ICP-MS. While aerosol flow rate and power appear to be the key ICP parameters in ICP-MS, ion signals are dependent on sampling depth and auxiliary flow rate and some data are also presented illustrating the signal dependence on these two parameters.

  5. Amorphous carbon film deposition on inner surface of tubes using atmospheric pressure pulsed filamentary plasma source

    CERN Document Server

    Pothiraja, Ramasamy; Awakowicz, Peter

    2011-01-01

    Uniform amorphous carbon film is deposited on the inner surface of quartz tube having the inner diameter of 6 mm and the outer diameter of 8 mm. A pulsed filamentary plasma source is used for the deposition. Long plasma filaments (~ 140 mm) as a positive discharge are generated inside the tube in argon with methane admixture. FTIR-ATR, XRD, SEM, LSM and XPS analyses give the conclusion that deposited film is amorphous composed of non-hydrogenated sp2 carbon and hydrogenated sp3 carbon. Plasma is characterized using optical emission spectroscopy, voltage-current measurement, microphotography and numerical simulation. On the basis of observed plasma parameters, the kinetics of the film deposition process is discussed.

  6. Microwave frequency sweep interferometer for plasma density measurements in ECR ion sources: Design and preliminary results

    Science.gov (United States)

    Torrisi, Giuseppe; Mascali, David; Neri, Lorenzo; Leonardi, Ornella; Sorbello, Gino; Celona, Luigi; Castro, Giuseppe; Agnello, Riccardo; Caruso, Antonio; Passarello, Santi; Longhitano, Alberto; Isernia, Tommaso; Gammino, Santo

    2016-02-01

    The Electron Cyclotron Resonance Ion Sources (ECRISs) development is strictly related to the availability of new diagnostic tools, as the existing ones are not adequate to such compact machines and to their plasma characteristics. Microwave interferometry is a non-invasive method for plasma diagnostics and represents the best candidate for plasma density measurement in hostile environment. Interferometry in ECRISs is a challenging task mainly due to their compact size. The typical density of ECR plasmas is in the range 1011-1013 cm-3 and it needs a probing beam wavelength of the order of few centimetres, comparable to the chamber radius. The paper describes the design of a microwave interferometer developed at the LNS-INFN laboratories based on the so-called "frequency sweep" method to filter out the multipath contribution in the detected signals. The measurement technique and the preliminary results (calibration) obtained during the experimental tests will be presented.

  7. Ion beam extraction from a matrix ECR plasma source by discrete ion-focusing effect

    DEFF Research Database (Denmark)

    Stamate, Eugen; Draghici, Mihai

    2010-01-01

    Positive or negative ion beams extracted from plasma are used in a large variety of surface functionalization techniques such as implantation, etching, surface activation, passivation or oxidation. Of particular importance is the surface treatment of materials sensitive to direct plasma exposure...... due to high heath fluxes, the controllability of the ion incidence angle, and charge accumulation when treating insulating materials. Despite of a large variety of plasma sources available for ion beam extraction, there is a clear need for new extraction mechanisms that can make available ion beams...... with high current densities that can treat surfaces placed adjacent to the extraction region. This work introduces a new phenomenology for ion beam extraction using the discrete ion-focusing effect associated with three-dimensional plasma-sheath-lenses [1, 2]. Experiments are performed in a matrix...

  8. Porcelain-coated antenna for radio-frequency driven plasma source

    Science.gov (United States)

    Leung, Ka-Ngo; Wells, Russell P.; Craven, Glen E.

    1996-01-01

    A new porcelain-enamel coated antenna creates a clean plasma for volume or surface-conversion ion sources. The porcelain-enamel coating is hard, electrically insulating, long lasting, non fragile, and resistant to puncture by high energy ions in the plasma. Plasma and ion production using the porcelain enamel coated antenna is uncontaminated with filament or extraneous metal ion because the porcelain does not evaporate and is not sputtered into the plasma during operation. Ion beams produced using the new porcelain-enamel coated antenna are useful in ion implantation, high energy accelerators, negative, positive, or neutral beam applications, fusion, and treatment of chemical or radioactive waste for disposal. For ion implantation, the appropriate species ion beam generated with the inventive antenna will penetrate large or small, irregularly shaped conducting objects with a narrow implantation profile.

  9. Microwave frequency sweep interferometer for plasma density measurements in ECR ion sources: Design and preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Torrisi, Giuseppe [INFN - Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); University Mediterranea of Reggio Calabria, Reggio Calabria (Italy); Mascali, David; Neri, Lorenzo; Leonardi, Ornella; Celona, Luigi; Castro, Giuseppe; Agnello, Riccardo; Caruso, Antonio; Passarello, Santi; Longhitano, Alberto; Gammino, Santo [INFN - Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); Sorbello, Gino [INFN - Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); University of Catania, Catania, Italy and INFN-LNS, Catania (Italy); Isernia, Tommaso [University Mediterranea of Reggio Calabria, Reggio Calabria (Italy)

    2016-02-15

    The Electron Cyclotron Resonance Ion Sources (ECRISs) development is strictly related to the availability of new diagnostic tools, as the existing ones are not adequate to such compact machines and to their plasma characteristics. Microwave interferometry is a non-invasive method for plasma diagnostics and represents the best candidate for plasma density measurement in hostile environment. Interferometry in ECRISs is a challenging task mainly due to their compact size. The typical density of ECR plasmas is in the range 10{sup 11}–10{sup 13} cm{sup −3} and it needs a probing beam wavelength of the order of few centimetres, comparable to the chamber radius. The paper describes the design of a microwave interferometer developed at the LNS-INFN laboratories based on the so-called “frequency sweep” method to filter out the multipath contribution in the detected signals. The measurement technique and the preliminary results (calibration) obtained during the experimental tests will be presented.

  10. Measurement of the Internal Magnetic Field of Plasmas using an Alpha Particle Source

    Energy Technology Data Exchange (ETDEWEB)

    S.J. Zweben; D.S. Darrow; P.W. Ross; J.L. Lowrance; G. Renda

    2004-05-13

    The internal magnetic fields of plasmas can be measured under certain conditions from the integrated v x B deflection of MeV alpha particles emitted by a small radioactive source. This alpha source and large-area alpha particle detector would be located inside the vacuum vessel but outside the plasma. Alphas with a typical energy of 5.5 MeV (241Am) can reach the center of almost all laboratory plasmas and magnetic fusion devices, so this method can potentially determine the q(r) profile of tokamaks or STs. Orbit calculations, background evaluations, and conceptual designs for such a vxB (or ''AVB'') detector are described.

  11. Laser-plasma electron accelerator for all-optical inverse Compton X-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Koyama, K. [University of Tokyo, 2-22 Shirakata shirane, Tokai-mura, Naka-gun, Ibaraki 319-1188 (Japan)], E-mail: koyama@nuclear.jp; Yamazaki, A.; Maekawa, A.; Uesaka, M. [University of Tokyo, 2-22 Shirakata shirane, Tokai-mura, Naka-gun, Ibaraki 319-1188 (Japan); Hosokai, T. [Tokyo Institute of Technology, 4259 Nagatsuda-cho, Midori-ku, Yokohama 226-8503 (Japan); Miyashita, M. [Tokyo University of Science, 2641 Yamazaki, Noda, Chiba 278-8510 (Japan); Masuda, S.; Miura, E. [AIST, Tsukuba-central-2, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan)

    2009-09-01

    Inverse Compton scattering has been gaining attention as a process for the generation of X/{gamma}-ray, since it produces tunable X/{gamma}-ray pulses with a small cone angle of radiation. A table-top tunable Compton X/{gamma}-ray source would be realized by replacing a radio frequency (rf) linac with a laser wakefield accelerator (LWFA), which is one of the advanced accelerators. An empirical scaling law for the LWFA in the self-injection mode showed that the energy gain was inversely proportional to the plasma density. In order to effectively employ the LWFA as a Compton X/{gamma}-ray source, its stability must be improved. For this purpose, we are developing techniques for the injection of initial electrons by a localized wavebreaking at the density ramp of a plasma. The pointing stability and acceleration efficiency of the electron beam were significantly improved by applying an axial magnetic field to the plasma channel.

  12. Determination of loperamide in human plasma and saliva by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Arafat, Tawfiq; Arafat, Basil; awad, Riad; awwad, Ahmad Abu

    2014-12-01

    A simple and sensitive liquid chromatography-tandem mass spectrometric method for quantification of loperamide in human plasma and saliva was developed and validated, and then successfully applied in pharmacokinetic clinical study to investigate and correlate bioavailability of Imodium(®) 2mg quartet tablet dose in both human plasma and saliva. Loperamide with labeled internal standard was extracted from its biological matrix by methanol as protein direct precipitant in single extraction step. Adequate chromatographic separation for analytes from plasma and saliva matrices was achieved using ACE C18 (50mm×2.1mm, 5μm) column, eluted by water/methanol/formic acid (30:70:0.1%, v/v), delivered isocratically at constant flow rate of 0.75ml/min. The method validation intends to investigate specificity, sensitivity, linearity, precision, accuracy, recovery, matrix effect and stability according to European guideline, and partial validation was applied on saliva, specificity, matrix effect, recovery, sensitivity, within and between day precision and accuracy. The calibration curve was linear through the range of 20-3000pg/ml in both plasma and saliva using a 50μl sample volume. The partial validation sections outcome in saliva was so close to those in plasma. The within- and between-day precisions were all below 8.7% for plasma and below 11.4% for saliva. Accuracies ranged from 94 to 105% for both matrices. In this study, 26 healthy volunteers participated in the clinical study, and 6 of gave their saliva samples in addition to plasma at the same time schedule. The pharmacokinetic parameters of Cmax, AUC0-t and AUC0-∞, Tmax and T1/2 in both plasma and saliva were calculated and correlated.

  13. Laser-Plasma Sources for Soft-X-Ray Projection Lithography

    NARCIS (Netherlands)

    F. Bijkerk,; Shmaenok, L.; Vanhonk, A.; Bastiaensen, R.; Platonov, Y. Y.; Shevelko, A. P.; Mitrofanov, A. V.; Voss, F.; Desor, R.; Frowein, H.; Nikolaus, B.

    1994-01-01

    Results are reported concerning high-repetition-rate excimer lasers with average powers up to 415 W and their usage for generating laser-plasma soft X-ray sources. A conversion efficiency of laser light into monochromatized soft X-ray radiation of 0.7% at 13.5 nm (2% bandwidth) was achieved using an

  14. Study of the general plasma characteristics of a high power multifilament ion source

    Energy Technology Data Exchange (ETDEWEB)

    Schoenberg, K.F.

    1979-09-01

    A general assessment of the steady state and time dependent plasma properties which characterize a high power multifilament ion source is presented. Steady state measurements, obtained via a pulsed electrostatic probe data acquisition system, are described. Fluctuation measurements, obtained via a broadband digital spectral analysis system, are also given.

  15. Finite element analysis of keyhole plasma arc welding based on an adaptive heat source mode

    Institute of Scientific and Technical Information of China (English)

    Hu Qingxian; Wu Chuansong; Zhang Yuming

    2007-01-01

    An adaptive heat source mode is proposed to account for the keyhole effect and the characteristics of volumetric distribution along the direction of the workpiece thickness. Finite element analysis of the temperature field in keyhole plasma arc welding is conducted and the weld geometry is obtained. The predicted results are in agreement with the measured ones.

  16. Laser-Plasma Sources for Soft-X-Ray Projection Lithography

    NARCIS (Netherlands)

    F. Bijkerk,; Shmaenok, L.; Vanhonk, A.; Bastiaensen, R.; Platonov, Y. Y.; Shevelko, A. P.; Mitrofanov, A. V.; Voss, F.; Desor, R.; Frowein, H.; Nikolaus, B.

    1994-01-01

    Results are reported concerning high-repetition-rate excimer lasers with average powers up to 415 W and their usage for generating laser-plasma soft X-ray sources. A conversion efficiency of laser light into monochromatized soft X-ray radiation of 0.7% at 13.5 nm (2% bandwidth) was achieved using an

  17. Evolution of plasma parameters in an Ar-N2/He inductive plasma source with magnetic pole enhancement

    Science.gov (United States)

    Maria, Younus; N, U. Rehman; M, Shafiq; M, Naeem; M, Zaka-Ul-Islam; M, Zakaullah

    2017-02-01

    Magnetic pole enhanced inductively coupled plasmas (MaPE-ICPs) are a promising source for plasma-based etching and have a wide range of material processing applications. In the present study Langmuir probe and optical emission spectroscopy were used to monitor the evolution of plasma parameters in a MaPE-ICP Ar-N2/He mixture plasma. Electron density ({n}{{e}}) and temperature ({T}{{e}}), excitation temperature ({T}{{exc}}), plasma potential ({V}{{p}}), skin depth (δ ) and the evolution of the electron energy probability function (EEPF) are reported as a function of radiofrequency (RF) power, pressure and argon concentration in the mixture. It is observed that {n}{{e}} increases while {T}{{e}} decreases with increase in RF power and argon concentration in the mixture. The emission intensity of the argon line at 750.4 nm is also used to monitor the variation of the ‘high-energy tail’ of the EEPF with RF power and gas pressure. The EEPF has a ‘bi-Maxwellian’ distribution at low RF powers and higher pressure in a pure {{{N}}}2 discharge. However, it evolves into a ‘Maxwellian’ distribution at RF powers greater than 70 W for pure {{{N}}}2, and at 50 W for higher argon concentrations in the mixture. The effect of argon concentration on the temperatures of two electron groups in the ‘bi-Maxwellian’ EEPF is examined. The temperature of the low-energy electron group {T}{{L}} shows a decreasing trend with argon addition until the ‘thermalization’ of the two temperatures occurs, while the temperature of high-energy electrons {T}{{H}} decreases continuously.

  18. High-power EUV lithography sources based on gas discharges and laser-produced plasmas

    Science.gov (United States)

    Stamm, Uwe; Ahmad, Imtiaz; Balogh, Istvan; Birner, H.; Bolshukhin, D.; Brudermann, J.; Enke, S.; Flohrer, Frank; G„bel, Kai; G÷tze, S.; Hergenhan, G.; Kleinschmidt, J.'rgen; Kl÷pfel, Diethard; Korobotchko, Vladimir; Ringling, Jens; Schriever, Guido; Tran, C. D.; Ziener, C.

    2003-06-01

    Semiconductor chip manufacturers are expecting to use extreme UV lithography for production in 2009. EUV tools require high power, brilliant light sources at 13.5 nm with collector optics producing 120 W average power at entrance of the illuminator system. Today the power and lifetime of the EUV light source are considered as the most critical issue for EUV lithography. The present paper gives an update of the development status of EUV light sources at XTREME technologies, a joint venture of Lambda Physik AG, Goettingen, and Jenoptik LOS GmbH, Jena, Germany. Results on both laser produced plasma (LPP) and gas discharge produced plasma (GDPP), the two major technologies in EUV sources, are given. The LPP EUV sources use xenon-jet target systems and pulsed lasers with 400 W average power at 10 kHz developed at XTREME technologies. The maximum conversion efficiency form laser power into EUV in-band power is 0.75% into 2π solid angle. With 300 W laser average power at 3300 Hz repetition rate up to 1.5 W EUV radiation is generated at 13.5 nm. After a collector of 5 sr this corresponds to 0.6 W in intermediate focus without spectral purity filter and 0.5 W in intermediate focus with spectral purity filter. The direct generation of the EUV emitting plasma from electrical discharges is much simpler than LPP because the electrical energy has not to be converted into laser radiation before plasma excitation. XTREME technologies' Xenon GDPP EUV sources use the Z-pinch principle with efficient sliding discharge pre-ionization. The plasma pinch size and the available emission angle have been matched to the etendue of the optical system of 2-3 mm2 sr, i.e. no additional etendue related loss reduces the usable EUV power from the source. In continuous operation at 1000 Hz the GDPP sources emit 50W into 2π solid angle are obtained from the Z-pinch sources. Spatial and temporal emission stability of the EUV sources is in the range of a few percent. Debris shields for EUV sources

  19. Detailed beam and plasma measurements on the vessel for extraction and source plasma analyses (VESPA) Penning H{sup −} ion source

    Energy Technology Data Exchange (ETDEWEB)

    Lawrie, S. R., E-mail: scott.lawrie@stfc.ac.uk [STFC ISIS Pulsed Spallation Neutron and Muon Facility, Rutherford Appleton Laboratory, Harwell, Oxford (United Kingdom); John Adams Institute of Accelerator Science, University of Oxford, Oxford (United Kingdom); Faircloth, D. C.; Letchford, A. P.; Whitehead, M. O.; Wood, T. [STFC ISIS Pulsed Spallation Neutron and Muon Facility, Rutherford Appleton Laboratory, Harwell, Oxford (United Kingdom)

    2016-02-15

    A vessel for extraction and source plasma analyses (VESPA) is operational at the Rutherford Appleton Laboratory (RAL). This project supports and guides the overall ion source R&D effort for the ISIS spallation neutron and muon facility at RAL. The VESPA produces 100 mA of pulsed H{sup −} beam, but perveance scans indicate that the source is production-limited at extraction voltages above 12 kV unless the arc current is increased. A high resolution optical monochromator is used to measure plasma properties using argon as a diagnostic gas. The atomic hydrogen temperature increases linearly with arc current, up to 2.8 eV for 50 A; whereas the electron temperature has a slight linear decrease toward 2.2 eV. The gas density is 10{sup 21} m{sup −3}, whilst the electron density is two orders of magnitude lower. Densities follow square root relationships with arc current, with gas density decreasing whilst electron (and hence ion) density increases. Stopping and range of ions in matter calculations prove that operating a high current arc with an argon admixture is extremely difficult because cathode-coated cesium is heavily sputtered by argon.

  20. Determination of salvianolic acid C in rat plasma using liquid chromatography-mass spectrometry and its application to pharmacokinetic study.

    Science.gov (United States)

    Song, Junke; Zhang, Wen; Sun, Jialin; Zhang, Xue; Xu, Xiaona; Zhang, Li; Feng, Zhangying; Du, Guanhua

    2016-03-01

    A sensitive and reliable LC-ESI-MS method for the determination of salvianolic acid C in rat plasma has been developed and validated. Plasma samples were prepared by liquid-liquid extraction with ethyl acetate and separated on a Zorbax SB-C18 column (3.5 µm, 2.1 × 100 mm) at a flow rate of 0.3 mL/min using acetonitrile-water as mobile phase. The detection was carried out by a single quadrupole mass spectrometer with electrospray ionization source and selected ion monitoring mode. Linearity was obtained for salvianolic acid C ranging from 5 to 1000 ng/mL. The intra- and inter-day precisions (RSD, %) didn't exceed 9.96%, and the accuracy (RE, %) were all within ±3.64%. The average recoveries of the analyte and internal standard were >89.13%. Salvianolic acid C was proved to be stable during all sample storage, preparation and analytic procedures. The validated method was successfully applied to pharmacokinetic study after oral and intravenous administration of salvianolic acid C to rats. The absolute oral bioavailability of salvianolic acid C was 0.29 ± 0.05%. This method was further applied to simultaneous determination of salvianolic acid A, salvianolic acid B and salvianolic acid C in rat plasma and showed good practicability.

  1. Ambipolar and non-ambipolar diffusion in an rf plasma source containing a magnetic filter

    Energy Technology Data Exchange (ETDEWEB)

    Lafleur, T., E-mail: trevor.lafleur@lpp.polytechnique.fr [Laboratoire de Physique des Plasmas, CNRS, Sorbonne Universités, UPMC Univ Paris 06, Univ Paris-Sud, Ecole Polytechnique, 91128 Palaiseau (France); ONERA-The French Aerospace Lab, 91120 Palaiseau (France); Aanesland, A. [Laboratoire de Physique des Plasmas, CNRS, Sorbonne Universités, UPMC Univ Paris 06, Univ Paris-Sud, Ecole Polytechnique, 91128 Palaiseau (France)

    2014-06-15

    By placing a magnetic filter across a rectangular plasma source (closed at one end with a ceramic plate and an rf antenna, and terminated at the opposite end by a grounded grid), we experimentally investigate the effect of conducting and insulating source walls on the nature of the plasma diffusion phenomena. The use of a magnetic filter creates a unique plasma, characterized by a high upstream electron temperature (T{sub e{sub u}}∼5 eV) near the rf antenna and a low downstream electron temperature (T{sub e{sub d}}∼1 eV) near the grid, which more clearly demonstrates the role of the source wall materials. For conducting walls a net ion current to ground is measured on the grid, and the plasma potential is determined by a mean electron temperature within the source. For insulating walls the plasma potential is determined by the downstream electron temperature (i.e., V{sub p}∼5.2T{sub e{sub d}} in argon), and the net current to the grid is exactly zero. Furthermore, by inserting a small additional upstream conductor (that can be made floating or grounded through an external circuit switch), we demonstrate that the plasma potential can be controlled and set to a low (V{sub p}∼5.2T{sub e{sub d}}), or high (V{sub p}∼5.2T{sub e{sub u}}) value.

  2. Plasma source by microwaves: design description; Fuente de plasma por microondas: descripcion de diseno

    Energy Technology Data Exchange (ETDEWEB)

    Camps, E.; Olea, O.; Andrade, R.; Anguiano, G

    1992-03-15

    The design of a device for the formation of a plasma with densities of the order of 10{sup 12} cm{sup -} {sup 3} and low temperatures (T{sub e} {approx} 40 eV) is described. For such purpose it was carried out in the device a microwave discharge (f{sub o} = 2.45 GHz) in a resonator of high Q factor, immersed in a static external magnetic field. The device worked in the regime {omega}{sub ce} {<=} {omega}{sub o}/2 ({omega}{sub ce}- cyclotron frequency of the electrons, ({omega}{sub o} = 2 {pi} f{sub o}) where is possible the excitement of non lineal phenomena of waves transformation. (Author)

  3. Multimycotoxin analysis in water and fish plasma by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Tolosa, J; Font, G; Mañes, J; Ferrer, E

    2016-02-01

    High performance liquid chromatography-mass spectrometry was used for the determination of 15 mycotoxins in water and fish plasma samples, including aflatoxins, fumonisins, ochratoxin A, sterigmatocistin, fusarenon-X and emerging Fusarium mycotoxins. In this work, dispersive liquid-liquid microextraction (DLLME) was assessed as a sample treatment for the simultaneous extraction of mycotoxins. Results showed differences in recovery assays when different extraction solvents were employed. Ethyl acetate showed better recoveries for the major part of mycotoxins analyzed, except for aflatoxins B2, G1 and G2, which showed better recoveries when employing chloroform as extractant solvent. Fumonisins and beauvericin exhibited low recoveries in both water and plasma. This method was validated according to guidelines established by European Commission and has shown to be suitable to be applied in dietary and/or toxicokinetic studies in fish where is necessary to check mycotoxin contents in rearing water and fish plasma.

  4. Determination of carbocysteine in human plasma by liquid chromatography/tandem mass spectrometry employing precolumn derivatization.

    Science.gov (United States)

    Chen, Xiaoyan; Zhong, Dafang; Han, Ying; Xie, Zhiyong

    2003-01-01

    A sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed to determine carbocysteine in human plasma using 2-pyridylacetic acid as the internal standard (IS). The method employed derivatization with 10 M hydrochloric acid/methanol, which significantly improved the ionization efficiency of carbocysteine. After methanol-induced protein precipitation of plasma samples, carbocysteine and the IS were derivatized and subjected to LC/MS/MS analysis using atmospheric pressure chemical ionization. The method has a lower limit of quantitation of 20 ng/mL for a 0.2-mL plasma aliquot. The intra- and inter-day precision (RSD), calculated from quality control (QC) samples, was less than 7%. The accuracy, determined using QC samples, was within +/- 1%. The method offered increased sensitivity, selectivity and speed of analysis over existing methods. The method was utilized to support clinical pharmacokinetic studies of carbocysteine in volunteers following oral administration. Copyright 2002 John Wiley & Sons, Ltd.

  5. Design and development of an interchangeable nanomicroelectrospray source for a quadrupole mass spectrometer

    Science.gov (United States)

    Smith, Douglas R.; Sagerman, Gary; Wood, Troy D.

    2003-10-01

    An interchangeable microelectrospray and nanoelectrospray ionization source has been designed and constructed for use on a triple-quadrupole mass spectrometer. This new source is specially designed to conduct nanoelectrospray experiments utilizing pulled borosilicate glass emitters, as well as various ionization modes utilizing silica capillaries. The source design facilitates the easy exchange between a microelectrospray source and nanoelectrospray source. The microionspray assembly can be quickly replaced by the nanoelectrospray adaptation in order to conduct nanoelectrospray experiments. Furthermore, this source design allows for the coupling of low flow separation techniques, like microliquid chromatography or capillary electrophoresis.

  6. Standard practice for alternate actinide calibration for inductively coupled plasma-mass spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This practice provides guidance for an alternate linear calibration for the determination of selected actinide isotopes in appropriately prepared aqueous solutions by Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). This alternate calibration is mass bias adjusted using thorium-232 (232Th) and uranium-238 (238U) standards. One of the benefits of this standard practice is the ability to calibrate for the analysis of highly radioactive actinides using calibration standards at much lower specific activities. Environmental laboratories may find this standard practice useful if facilities are not available to handle the highly radioactive standards of the individual actinides of interest. 1.2 The instrument response for a series of determinations of known concentration of 232Th and 238U defines the mass versus response relationship. For each standard concentration, the slope of the line defined by 232Th and 238U is used to derive linear calibration curves for each mass of interest using interference equ...

  7. Effect of catecholamines and insulin on plasma volume and intravascular mass of albumin in man

    DEFF Research Database (Denmark)

    Hilsted, J; Christensen, N J; Larsen, S

    1989-01-01

    1. The effect of intravenous catecholamine infusions and of intravenous insulin on plasma volume and intravascular mass of albumin was investigated in healthy males. 2. Physiological doses of adrenaline (0.5 microgram/min and 3 microgram/min) increased peripheral venous packed cell volume...... significantly; intravenous noradrenaline at 0.5 microgram/min had no effect on packed cell volume, whereas packed cell volume increased significantly at 3 micrograms of noradrenaline/min. No significant change in packed cell volume was found during saline infusion. 3. During adrenaline infusion at 6 micrograms...... in packed cell volume, plasma volume, intravascular mass of albumin and transcapillary escape rate of albumin during hypoglycaemia may be explained by the combined actions of adrenaline and insulin....

  8. A multi-sample changer coupled to an electron cyclotron resonance source for accelerator mass spectrometry experiments.

    Science.gov (United States)

    Vondrasek, R; Palchan, T; Pardo, R; Peters, C; Power, M; Scott, R

    2014-02-01

    A new multi-sample changer has been constructed allowing rapid changes between samples. The sample changer has 20 positions and is capable of moving between samples in 1 min. The sample changer is part of a project using Accelerator Mass Spectrometry (AMS) at the Argonne Tandem Linac Accelerator System (ATLAS) facility to measure neutron capture rates on a wide range of actinides in a reactor environment. This project will require the measurement of a large number of samples previously irradiated in the Advanced Test Reactor at Idaho National Laboratory. The AMS technique at ATLAS is based on production of highly charged positive ions in an electron cyclotron resonance ion source followed by acceleration in the ATLAS linac. The sample material is introduced into the plasma via laser ablation chosen to limit the dependency of material feed rates upon the source material composition as well as minimize cross-talk between samples.

  9. On the efficiency of stochastic volume sources for the determination of light meson masses

    CERN Document Server

    Endress, E; Wittig, H

    2011-01-01

    We investigate the efficiency of single timeslice stochastic sources for the calculation of light meson masses on the lattice as one varies the quark mass. Simulations are carried out with Nf = 2 flavours of non-perturbatively O(a) improved Wilson fermions for pion masses in the range of 450 - 760 MeV. Results for pseudoscalar and vector meson two-point correlation functions computed using stochastic as well as point sources are presented and compared. At fixed computational cost the stochastic approach reduces the variance considerably in the pseudoscalar channel for all simulated quark masses. The vector channel is more affected by the intrinsic stochastic noise. In order to obtain stable estimates of the statistical errors and a more pronounced plateau for the effective vector meson mass, a relatively large number of stochastic sources must be used.

  10. Thorium colloid analysis by single particle inductively coupled plasma-mass spectrometry.

    Science.gov (United States)

    Degueldre, C; Favarger, P-Y

    2004-04-19

    Thorium colloid analysis in water has been carried out by a single particle mode using inductively coupled plasma mass spectrometry (ICP-MS). The flash of ions due to the ionisation of a thorium colloidal particle in the plasma torch can be detected and measured in a time scan for (232)Th (+ ) or (248)[ThO] (+ ) according to the sensitivity required by the mass spectrometer. The peaks of the recorded intensity of the MS signal can be analysed as a function of the particle size or fraction of the studied element in the colloid phase. The frequency of the flashes is directly proportional to the concentration of particles in the colloidal suspension. After discussing Th colloid detection, on the basis of the intensity of the ion flashes generated in the plasma torch, tests were performed on thorium dioxide colloidal particles. This feasibility study also describes the experimental conditions and the limitation of the plasma design to detect thorium colloids in a single particle analysis mode down to about 10fg.

  11. Reduction of plyatomic ion interferences in indictively coupled plasma mass spectrometry with cryogenic desolvation

    Energy Technology Data Exchange (ETDEWEB)

    Alves, L.C.

    1993-09-01

    A desolvation scheme for introducing aqueous and organic samples into an argon inductively coupled plasma is described; the aerosol generated by nebulizer is heated (+140 C) and cooled ({minus}80 C) repeatedly, and the dried aerosol is then injected into the mass spectrometer. Polyatomic ions are greatly suppressed. This scheme was validated with analysis of seawater and urine reference samples. Finally, the removal of organic solvents by cryogenic desolvation was studied.

  12. Determination of diclofenac concentrations in human plasma using a sensitive gas chromatography mass spectrometry method

    OpenAIRE

    2016-01-01

    Background A gas chromatography mass spectrometry (GCMS) method for the determination of diclofenac in human plasma has been developed and validated. Results This method utilizes hexane which is a relatively less toxic extraction solvent compared to heptane and benzene. In addition, phosphoric acid and acetone were added to the samples as deproteination agents, which increased the recovery of diclofenac. These revised processes allow clean extraction and near-quantitative recovery of analyte ...

  13. Determination of diclofenac concentrations in human plasma using a sensitive gas chromatography mass spectrometry method

    OpenAIRE

    Shah, Iltaf; Barker, James; Naughton, Declan P; Barton, Stephen J.; Ashraf, Syed Salman

    2016-01-01

    Background\\ud A gas chromatography mass spectrometry (GCMS) method for the determination of diclofenac in human plasma has been developed and validated.\\ud \\ud Results\\ud This method utilizes hexane which is a relatively less toxic extraction solvent compared to heptane and benzene. In addition, phosphoric acid and acetone were added to the samples as deproteination agents, which increased the recovery of diclofenac. These revised processes allow clean extraction and near-quantitative recover...

  14. Human Plasma N-Glycoproteome Analysis by Immunoaffinity Subtraction, Hydrazide Chemistry, and Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Tao; Qian, Weijun; Gritsenko, Marina A.; Camp, David G.; Monroe, Matthew E.; Moore, Ronald J.; Smith, Richard D.

    2005-12-01

    The enormous complexity, wide dynamic range of relative protein abundance of interest (over 10 orders of magnitude), and tremendous heterogeneity (due to post-translational modifications, such as glycosylation) of the human blood plasma proteome severely challenges the capabilities of existing analytical methodologies. We describe here the comprehensive analysis of human plasma N-glycoproteins using the combination of immunoaffinity subtraction and glycoprotein capture to reduce both the protein concentration range and the overall sample complexity. Six high-abundance plasma proteins were simultaneously removed using a pre-packed, immobilized antibody column. N-linked glycoproteins were then captured from the depleted plasma using hydrazide resin, enzymatically digested, and the bound, N-linked glycopeptides were released using peptide-N-glycosidase F. Following strong cation exchange (SCX) fractionation, the deglycosylated peptides were analyzed by reversed-phase capillary liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). A total of 2140 different N-glycopeptides were confidently identified using stringent criteria, covering 371 non-redundant N-glycoproteins with the majority of them being extracellular or membrane proteins. The strategy significantly improved the detection, enabling the identification of a number of low-abundance proteins, exemplified by interleukin-1 receptor antagonist protein ({approx}200 pg/mL), cathepsin L ({approx}1 ng/mL), and transforming growth factor beta 1 ({approx}2 ng/mL). A total of 712 N-glycosylation sites were identified and the confidence of these site identifications was further validated by accurate mass measurements using high resolution liquid chromatography coupled to Fourier transform ion cyclotron resonance mass spectrometry (LC-FTICR). This study provides the basis for future high-throughput measurements using the accurate mass and time tag approach.

  15. Imaging gold nanoparticles in mouse liver by laser ablation inductively coupled plasma mass spectrometry

    OpenAIRE

    Li, Qing; Wang, Zheng; Mo, Jiamei; Zhang, Guoxia; Chen, Yirui; Huang, Chuchu

    2017-01-01

    Imaging the size distribution of metal nanoparticles (NPs) in a tissue has important implications in terms of evaluating NP toxicity. Microscopy techniques used to image tissue NPs are limited by complicated sample preparation or poor resolution. In this study, we developed a laser ablation (LA) system coupled to single-particle inductively coupled plasma mass spectrometry (SP-ICP-MS) for quantitative imaging of gold (G)NPs in tissue samples. In this system, GNPs were ablated but did not disi...

  16. Plasma free and total carnitine measured in children by tandem mass spectrometry

    OpenAIRE

    J.H. Osorio; Pourfarzam, M.

    2002-01-01

    Free and total carnitine quantification is important as a complementary test for the diagnosis of unusual metabolic diseases, including fatty acid degradation disorders. The present study reports a new method for the quantification of free and total carnitine in dried plasma specimens by isotope dilution electrospray tandem mass spectrometry with sample derivatization. Carnitine is determined by looking for the precursor of ions of m/z = 103 of N-butylester derivative, and the method is valid...

  17. Analysis of estrogens and androgens in postmenopausal serum and plasma by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Wang, Qingqing; Bottalico, Lisa; Mesaros, Clementina; Blair, Ian A

    2015-07-01

    Liquid chromatography-selected reaction monitoring/mass spectrometry-based methodology has evolved to the point where accurate analyses of trace levels of estrogens and androgens in postmenopausal serum and plasma can be accomplished with high precision and accuracy. A suite of derivatization procedures has been developed, which together with modern mass spectrometry instrumentation provide investigators with robust and sensitive methodology. Pre-ionized derivatives are proving to be useful as they are not subject to suppression of the electrospray signal. Postmenopausal women with elevated plasma or serum estrogens are thought to be at increased risk for breast and endometrial cancer. Therefore, significant advances in risk assessment should be possible now that reliable methodology is available. It is also possible to conduct analyses of multiple estrogens in plasma or serum. Laboratories that are currently employing liquid chromatography/mass spectrometry methodology can now readily implement this strategy. This will help conserve important plasma and serum samples available in Biobanks, as it will be possible to conduct high sensitivity analyses using low initial sample volumes. Reported levels of both conjugated and non-conjugated estrogen metabolites are close to the limits of sensitivity of many assays to date, urging caution in the interpretation of these low values. The analysis of serum androgen precursors in postmenopausal women has not been conducted routinely in the past using liquid chromatography/mass spectrometry methodology. Integration of serum androgen levels into the panel of metabolites analyzed could provide additional information for assessing cancer risk and should be included in the future.

  18. Measurements and modeling of the impact of weak magnetic fields on the plasma properties of a planar slot antenna driven plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Jun, E-mail: jun.yoshikawa@tel.com; Susa, Yoshio; Ventzek, Peter L. G. [Tokyo Electron Ltd., Akasaka Biz Tower, 3-1 Akasaka 5-chome, Minato-ku, Tokyo 107-6325 (Japan)

    2015-05-15

    The radial line slot antenna plasma source is a type of surface wave plasma source driven by a planar slot antenna. Microwave power is transmitted through a slot antenna structure and dielectric window to a plasma characterized by a generation zone adjacent to the window and a diffusion zone that contacts a substrate. The diffusion zone is characterized by a very low electron temperature. This renders the source useful for soft etch applications and thin film deposition processes requiring low ion energy. Another property of the diffusion zone is that the plasma density tends to decrease from the axis to the walls under the action of ambipolar diffusion at distances far from where the plasma is generated. A previous simulation study [Yoshikawa and. Ventzek, J. Vac. Sci. Technol. A 31, 031306 (2013)] predicted that the anisotropy in transport parameters due to weak static magnetic fields less than 50 G could be leveraged to manipulate the plasma profile in the radial direction. These simulations motivated experimental tests in which weak magnetic fields were applied to a radial line slot antenna source. Plasma absorption probe measurements of electron density and etch rate showed that the magnetic fields remote from the wafer were able to manipulate both parameters. A summary of these results is presented in this paper. Argon plasma simulation trends are compared with experimental plasma and etch rate measurements. A test of the impact of magnetic fields on charge up damage showed no perceptible negative effect.

  19. Biological stimulation of the Human skin applying health promoting light and plasma sources

    Energy Technology Data Exchange (ETDEWEB)

    Awakowicz, P.; Bibinov, N. [Center for Plasma Science and Technology, Ruhr-University, Bochum (Germany); Born, M.; Niemann, U. [Philips Research, Aachen (Germany); Busse, B. [Zell-Kontakt GmbH, Noerten-Hardenberg (Germany); Gesche, R.; Kuehn, S.; Porteanu, H.E. [Ferdinand-Braun-Institut fuer Hoechstfrequenztechnik, Berlin (Germany); Helmke, A. [University of Applied Sciences and Arts, Goettingen (Germany); Kaemling, A.; Wandke, D. [CINOGY GmbH, Duderstadt (Germany); Kolb-Bachofen, V.; Liebmann, J. [Institute for Immunobiology, Heinrich-Heine University, Duesseldorf (Germany); Kovacs, R.; Mertens, N.; Scherer, J. [Aurion Anlagentechnik GmbH, Seligenstadt (Germany); Oplaender, C.; Suschek, C. [Clinic for Plastic Surgery, University Clinic, Aachen (Germany); Vioel, W. [Laser-Laboratorium, Goettingen (Germany); University of Applied Sciences and Arts, Goettingen (Germany)

    2009-10-15

    In the frame of BMBF project ''BioLiP'', new physical treatment techniques aiming at medical treatment of the human skin have been developed. The acronym BioLiP stands for ''Desinfektion, Entkeimung und biologische Stimulation der Haut durch gesundheitsfoerdernde Licht- und Plasmaquellen'' (Disinfection, germ reduction and biological stimulation of the human skin by health promoting light and plasma sources). A source applying a low-temperature dielectric barrier discharge plasma (DBD) has been investigated on its effectiveness for skin disinfection and stimulation of biological material. Alternatively an atmospheric plasma source consisting of a microwave resonator combined with a solid state power oscillator has been examined. This concept which allows for a compact and efficient design avoiding external microwave power supply and matching units has been optimized with respect to nitrogen monoxide (NO) production in high yields. In both cases various application possibilities in the medical and biological domain are opened up. Light sources in the visible spectral range have been investigated with respect to the proliferation of human cell types. Intensive highly selective blue light sources based on LED technology can slow down proliferation rates without inducing toxic effects which offers new opportunities for treatments of so-called hyperproliferative skin conditions (e.g. with psoriasis or in wound healing) using UV-free light. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  20. Identification of novel circulating coffee metabolites in human plasma by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Redeuil, Karine; Smarrito-Menozzi, Candice; Guy, Philippe; Rezzi, Serge; Dionisi, Fabiola; Williamson, Gary; Nagy, Kornél; Renouf, Mathieu

    2011-07-22

    This study reports a liquid chromatography-mass spectrometry method for the detection of polyphenol-derived metabolites in human plasma without enzymatic treatment after coffee consumption. Separation of available standards was achieved by reversed-phase ultra performance liquid chromatography and detection was performed by high resolution mass spectrometry in negative electrospray ionization mode. This analytical method was then applied for the identification and relative quantification of circulating coffee metabolites. A total of 34 coffee metabolites (mainly reduced, sulfated and methylated forms of caffeic acid, coumaric acid, caffeoylquinic acid and caffeoylquinic acid lactone) were identified based on mass accuracy (<4 ppm for most metabolites), specific fragmentation pattern and co-chromatography (when standard available). Among them, 19 circulating coffee metabolites were identified for the first time in human plasma such as feruloylquinic acid lactone, sulfated and glucuronidated forms of feruloylquinic acid lactone and sulfated forms of coumaric acid. Phenolic acid derivatives such as dihydroferulic acid, dihydroferulic acid 4'-O-sulfate, caffeic acid 3'-O-sulfate, dimethoxycinnamic acid, dihydrocaffeic acid and coumaric acid O-sulfate appeared to be the main metabolites circulating in human plasma after coffee consumption. The described method is a sensitive and reliable approach for the identification of coffee metabolites in biological fluids. In future, this analytical method will give more confidence in compound identification to provide a more comprehensive assessment of coffee polyphenol bioavailability studies in humans.

  1. Ambient low temperature plasma etching of polymer films for secondary ion mass spectrometry molecular depth profiling.

    Science.gov (United States)

    Muramoto, Shin; Staymates, Matthew E; Brewer, Tim M; Gillen, Greg

    2012-12-18

    The feasibility of a low temperature plasma (LTP) probe as a way to prepare polymer bevel cross sections for secondary ion mass spectrometry (SIMS) applications was investigated. Poly(lactic acid) and poly(methyl methacrylate) films were etched using He LTP, and the resulting crater walls were depth profiled using time-of-flight secondary ion mass spectrometry (ToF-SIMS) to examine changes in chemistry over the depth of the film. ToF-SIMS results showed that while exposure to even 1 s of plasma resulted in integration of atmospheric nitrogen and contaminants to the newly exposed surface, the actual chemical modification to the polymer backbone was found to be chemistry-dependent. For PLA, sample modification was confined to the top 15 nm of the PLA surface regardless of plasma exposure dose, while measurable change was not seen for PMMA. The confinement of chemical modification to 15 nm or less of the top surface suggests that LTP can be used as a simple method to prepare cross sections or bevels of polymer thin films for subsequent analysis by surface-sensitive molecular depth profiling techniques such as SIMS, X-ray photoelectron spectroscopy (XPS), and other spatially resolved mass spectrometric techniques.

  2. Determination of Candesartan in Human Plasma with Liquid Chromatography - Tandem Mass Spectrometry.

    Science.gov (United States)

    Forjan, Vanja; Cvitkovič Maričič, Lea; Prosen, Helena; Brodnjak Vončina, Darinka

    2016-01-01

    A sensitive, specific and rapid liquid chromatography - tandem mass spectrometry method was developed and validated for the determination of candesartan in human plasma. Analyte was separated from endogenous components present in plasma by solid phase extraction. Chromatographic separation was performed on Gemini C18 analytical column using mobile phase acetonitrile - 5 mM ammonium formate pH 2 (90:10, v/v) at flow rate of 0.3 mL/min. For detection, tandem mass spectrometry in SRM mode with positive electrospray ionization was used. The mass transitions m/z 441.1 > 263.1 and 445.1 > 267.1 were used to determine candesartan by using candesartan-d4 as an internal standard. After development, the method was validated according to the requirements of EMA regulatory guidelines in the concentration range 1 - 400 ng/ml in human plasma. Limit of quantification (LLOQ) was 1 ng/ml. The developed and validated method proved to be very fast and reproducible and was therefore successfully implemented in pharmacokinetic and bioequivalence studies with large number of study samples.

  3. A compact tunable polarized X-ray source based on laser-plasma helical undulators

    CERN Document Server

    Luo, Ji; Zeng, Ming; Vieira, Jorge; Yu, Lu-Le; Weng, Su-Ming; Silva, Luis O; Jaroszynski, Dino A; Sheng, Zheng-Ming; Zhang, Jie

    2016-01-01

    Laser wakefield accelerators have great potential as the basis for next generation compact radiation sources because their accelerating gradients are three orders of magnitude larger than traditional accelerators. However, X-ray radiation from such devices still lacks of tunability, especially the intensity and polarization distribution. Here we propose a tunable polarized radiation source from a helical plasma undulator based on plasma channel guided wakefield accelerator. When a laser pulse is initially incident with a skew angle relative to the channel axis, the laser and accelerated electrons experience collective spiral motions, which leads to elliptically polarized synchrotron-like radiation with flexible tunability on radiation intensity, spectra and polarization. We demonstrate that a radiation source with millimeter size and peak brilliance of $2\\times10^{19} photons/s/mm^{2}/mrad^{2}/0.1%$ bandwidth can be made with moderate laser and electron beam parameters. This brilliance is comparable with the ...

  4. Three-Dimensional Numerical Simulation of Surface-Wave Plasma Source

    Institute of Scientific and Technical Information of China (English)

    LAN Chaohui; CHEN Zhaoquan; LIU Minghai; JIANG Zhonghe; HU Xiwei

    2009-01-01

    A three-dimensional model of a surface-wave plasma(SWP)source is built numerically using the finite-difference time-domain(FDTD)method to investigate the structure of the surface wave propagation along the plasma-dielectric interface and the distributions of electromagnetic fields in the whole system.A good-performance excitation source technique for the waveguide which is pivotal to the simulation is presented.The technique can avoid the dc distortions of magnetic fields caused by the forcing electric wall.An example of simulation is given to confirm the existence of the surface waves.The simulation also shows that the code developed is a useful tool in the computer-aided design of the antenna of the SWP source.

  5. Ion Source for Neutral beam injection meant for plasma and magnetic field diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Vainionpaa, Jaakko Hannes; Leung, Ka Ngo; Gough, Richard A.; Kwan, Joe W.; Levinton, Fred

    2007-06-01

    At the Lawrence Berkeley National Laboratory (LBNL) a diagnostic neutral beam injection system for measuring plasma parameters, flow velocity, and local magnetic field is being developed. The systems is designed to have a 90 % proton fraction and small divergence with beam current at 5-6 A and a pulse length of {approx}1 s occurring once every 1-2 min. The ion source needs to generate uniform plasma over a large (8 cm x 5 cm) extraction area. For this application, we have compared RF driven multicusp ion sources operating with either an external or an internal antenna in similar ion source geometry. The ion beam will be made of an array of six sheet-shaped beamlets. The design is optimized using computer simulation programs.

  6. Integrated MEMS mass sensor and atom source for a ``Fab on a Chip''

    Science.gov (United States)

    Han, Han; Imboden, Matthias; Stark, Thomas; Bishop, David

    2014-03-01

    ``Fab on a Chip'' is a new concept suggesting that the semiconductor fabrication facility can be integrated into a single silicon chip for nano-manufacturing. Such a chip contains various MEMS devices which can work together, operating in a similar way as a conventional fab does, to fabricate nano-structures. Here we present two crucial ``Fab on a chip'' components: the MEMS mass sensor and atomic evaporation source. The mass sensor is essentially a parallel plate capacitor with one suspended plate. When incident atoms deposit on the suspended plate, the mass change of the plate can be measured by detecting the resonant frequency shift. Using the mass sensor, a mass resolution of 3 fg is achieved. The MEMS evaporation source consists of a polysilicon plate suspended by two electrical leads with constrictions. By resistively heating the plate, this device works as a tunable atom flux source. By arranging many of these devices into an array, one can build a multi-element atom evaporator. The mass sensor and atom source are integrated so that the mass sensor is used to monitor and characterize the atomic flux. A material source and a sensor to monitor the fabrication are two integral components for our ``Fab on a Chip.''

  7. Plasma Outages in Pulsed, High-Power RF Hydrogen Ion Sources

    Science.gov (United States)

    Stockli, Martin; Han, Baoxi; Murray, Syd; Pennisi, Terry; Piller, Chip; Santana, Manuel; Welton, Robert

    2011-04-01

    Pulsed, high-power RF ion sources are needed to produce copious amounts of negative H-ions for high-power accelerators with charge-changing injection schemes. When increasing the RF power, the plasma inductance changes the RF resonance, which drifts away from the low-power resonance. When the RF circuit is tuned to maximize the (pulsed) plasma power, the (off-resonance) power at the beginning of the pulse is reduced. If the induced electric fields fall below the breakdown strength of the hydrogen gas, the plasma fails to develop. This can be avoided with a compromise tune and/or by increasing the inductance of the resonant circuit. However, the breakdown strength of the hydrogen gas increases with time due to the gradual decrease of the electron-rich plasma impurities, which causes plasma outages after weeks of reliable operation. In this paper we discuss the success of different mitigations that were tested and implemented to overcome this fundamental problem of pulsed, high-power RF hydrogen ion sources.

  8. Myoglobin plasma level related to muscle mass and fiber composition: a clinical marker of muscle wasting?

    Science.gov (United States)

    Weber, Marc-André; Kinscherf, Ralf; Krakowski-Roosen, Holger; Aulmann, Michael; Renk, Hanna; Künkele, Annette; Edler, Lutz; Kauczor, Hans-Ulrich; Hildebrandt, Wulf

    2007-08-01

    Progressive muscle wasting is a central feature of cancer-related cachexia and has been recognized as a determinant of poor prognosis and quality of life. However, until now, no easily assessable clinical marker exists that allows to predict or to track muscle wasting. The present study evaluated the potential of myoglobin (MG) plasma levels to indicate wasting of large locomotor muscles and, moreover, to reflect the loss of MG-rich fiber types, which are most relevant for daily performance. In 17 cancer-cachectic patients (weight loss 22%) and 27 age- and gender-matched healthy controls, we determined plasma levels of MG and creatine kinase (CK), maximal quadriceps muscle cross-sectional area (CSA) by magnetic resonance imaging, muscle morphology and fiber composition in biopsies from the vastus lateralis muscle, body cell mass (BCM) by impedance technique as well as maximal oxygen uptake (VO(2)max). In cachectic patients, plasma MG, muscle CSA, BCM, and VO(2)max were 30-35% below control levels. MG showed a significant positive correlation to total muscle CSA (r = 0.65, p max as an important functional readout. CK plasma levels appear to be less reliable because prolonged increases are observed in even subclinical myopathies or after exercise. Notably, cancer-related muscle wasting was not associated with increases in plasma MG or CK in this study.

  9. Mass and energy analysis of the ions in a plasma flood system

    Energy Technology Data Exchange (ETDEWEB)

    Wooding, A.C. [Institute of Materials Research, University of Salford, Salford M54WT (United Kingdom); Armour, D.G. [Institute of Materials Research, University of Salford, Salford M54WT (United Kingdom); Berg, J.A. van den [Institute of Materials Research, University of Salford, Salford M54WT (United Kingdom)]. E-mail: j.a.vandenberg@salford.ac.uk; Holmes, A.J.T. [Marcham Scientific, Hungerford, Berks RG17 0LH (United Kingdom); Burgess, C. [Applied Materials UK Ltd., Foundry Lane, Horsham, West Sussex RH13 5PX (United Kingdom); Goldberg, R.D. [Applied Materials UK Ltd., Foundry Lane, Horsham, West Sussex RH13 5PX (United Kingdom)

    2005-08-01

    Plasma flood systems, capable of providing a copious supply of electrons are used in ion implanters to control wafer charging and provide effective space charge neutralisation of the ion beam in the post-analysis/post-deceleration section of the beamline. Under appropriate conditions the plasma from the flood system interacts with the ion beam and this bridging leads to an enhanced beam transport efficiency in the final critical stage of the beamline. The effectiveness of this process depends on the properties of the plasma emanating from the system. In this study, a plasma analyser comprising a double hemi-spherical electrostatic energy analyser and a quadrupole mass spectrometer, was used to measure the energy distributions of all the ion species leaving a magnetically confined argon plasma, generated in the discharge chamber of a conventional flood neutraliser. The energy distributions extended to surprisingly high energies and the peak structures depended strongly on discharge voltage, discharge current and gas pressure. The nature of these dependencies was complex with both the pressure and arc current affecting the way in which the ion energy distributions depended on arc voltage. In all cases, multiply charged ions played a significant role in determining the nature of the ion energy distributions.

  10. A method for studies on interactions between a gold-based drug and plasma proteins based on capillary electrophoresis with inductively coupled plasma mass spectrometry detection

    DEFF Research Database (Denmark)

    Nguyen, Tam T T N; Østergaard, Jesper; Gammelgaard, Bente

    2015-01-01

    An analytical method based on capillary electrophoresis (CE) and inductively coupled plasma mass spectrometry (ICP-MS) detection was developed for studies on the interaction of gold-containing drugs and plasma proteins using auranofin as example. A detection limit of 18 ng/mL of auranofin...... was the major auranofin-interacting protein in plasma. The CE-ICP-MS method is proposed as a novel approach for kinetic studies of the interactions between gold-based drugs and plasma proteins. Graphical Abstract Development of a CE-ICP-MS based method allows for studies on interaction of the gold containing...

  11. Pulsed, Inductively Generated, Streaming Plasma Ion Source for Heavy Ion Fusion Linacs

    Energy Technology Data Exchange (ETDEWEB)

    Steven C. Glidden; Howard D Sanders; John B. Greenly; Daniel L. Dongwoo

    2006-04-28

    This report describes a compact, high current density, pulsed ion source, based on electrodeless, inductively driven gas breakdown, developed to meet the requirements on normalized emittance, current density, uniformity and pulse duration for an ion injector in a heavy-ion fusion driver. The plasma source produces >10 μs pulse of Argon plasma with ion current densities >100 mA/cm2 at 30 cm from the source and with strongly axially directed ion energy of about 80 eV, and sub-eV transverse temperature. The source has good reproducibility and spatial uniformity. Control of the current density during the pulse has been demonstrated with a novel modulator coil method which allows attenuation of the ion current density without significantly affecting the beam quality. This project was carried out in two phases. Phase 1 used source configurations adapted from light ion sources to demonstrate the feasibility of the concept. In Phase 2 the performance of the source was enhanced and quantified in greater detail, a modulator for controlling the pulse shape was developed, and experiments were conducted with the ions accelerated to >40 kV.

  12. An Optical Streak Diagnostic for Observing Anode-Cathode Plasmas for Radiographic Source Development

    Energy Technology Data Exchange (ETDEWEB)

    Droemer, Darryl W. [National Security Technologies, LLC; Crain, Marlon D.; Lare, Gregory A. [National Security Technologies, LLC; Bennett, Nichelle L. [National Security Technologies, LLC; Johnston, Mark D. [Sandia National Laboratories

    2013-06-13

    National Security Technologies, LLC, and Sandia National Laboratories are collaborating in the development of pulsed power–driven flash x-ray radiographic sources that utilize high-intensity electron beam diodes. The RITS 6 (Radiographic Integrated Test Stand) accelerator at Sandia is used to drive a self magnetic pinch diode to produce a Bremsstrahlung x-ray source. The high electric fields and current densities associated with these short A-K gap pinch beam diodes present many challenges in diode development. Plasmas generated at both the anode and cathode affect the diode performance, which is manifested in varying spot (source) sizes, total dose output, and impedance profiles. Understanding the nature of these plasmas including closure rates and densities is important in modeling their behavior and providing insight into their mitigation. In this paper we describe a streak camera–based optical diagnostic that is capable of observing and measuring plasma evolution within the A-K gap. By imaging a region of interest onto the input slit of a streak camera, we are able to produce a time-resolved one-dimensional image of the evolving plasma. Typical data are presented.

  13. L-shell spectroscopic diagnostics of radiation from krypton HED plasma sources

    Science.gov (United States)

    Petkov, E. E.; Safronova, A. S.; Kantsyrev, V. L.; Shlyaptseva, V. V.; Rawat, R. S.; Tan, K. S.; Beiersdorfer, P.; Hell, N.; Brown, G. V.

    2016-11-01

    X-ray spectroscopy is a useful tool for diagnosing plasma sources due to its non-invasive nature. One such source is the dense plasma focus (DPF). Recent interest has developed to demonstrate its potential application as a soft x-ray source. We present the first spectroscopic studies of krypton high energy density plasmas produced on a 3 kJ DPF device in Singapore. In order to diagnose spectral features, and to obtain a more comprehensive understanding of plasma parameters, a new non-local thermodynamic equilibrium L-shell kinetic model for krypton was developed. It has the capability of incorporating hot electrons, with different electron distribution functions, in order to examine the effects that they have on emission spectra. To further substantiate the validity of this model, it is also benchmarked with data gathered from experiments on the electron beam ion trap (EBIT) at Lawrence Livermore National Laboratory, where data were collected using the high resolution EBIT calorimeter spectrometer.

  14. L-shell spectroscopic diagnostics of radiation from krypton HED plasma sources

    Energy Technology Data Exchange (ETDEWEB)

    Petkov, E. E., E-mail: emilp@unr.edu; Safronova, A. S.; Kantsyrev, V. L.; Shlyaptseva, V. V. [University of Nevada, Reno, Nevada 89557 (United States); Rawat, R. S.; Tan, K. S. [National Institute of Education, Nanyang Technological University, Singapore 637616 (Singapore); Beiersdorfer, P.; Brown, G. V. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Hell, N. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Dr. Remeis-Sternwarte and ECAP, Universität Erlangen-Nürnberg, 96049 Bamberg (Germany)

    2016-11-15

    X-ray spectroscopy is a useful tool for diagnosing plasma sources due to its non-invasive nature. One such source is the dense plasma focus (DPF). Recent interest has developed to demonstrate its potential application as a soft x-ray source. We present the first spectroscopic studies of krypton high energy density plasmas produced on a 3 kJ DPF device in Singapore. In order to diagnose spectral features, and to obtain a more comprehensive understanding of plasma parameters, a new non-local thermodynamic equilibrium L-shell kinetic model for krypton was developed. It has the capability of incorporating hot electrons, with different electron distribution functions, in order to examine the effects that they have on emission spectra. To further substantiate the validity of this model, it is also benchmarked with data gathered from experiments on the electron beam ion trap (EBIT) at Lawrence Livermore National Laboratory, where data were collected using the high resolution EBIT calorimeter spectrometer.

  15. High current multicharged metal ion source using high power gyrotron heating of vacuum arc plasma.

    Science.gov (United States)

    Vodopyanov, A V; Golubev, S V; Khizhnyak, V I; Mansfeld, D A; Nikolaev, A G; Oks, E M; Savkin, K P; Vizir, A V; Yushkov, G Yu

    2008-02-01

    A high current, multi charged, metal ion source using electron heating of vacuum arc plasma by high power gyrotron radiation has been developed. The plasma is confined in a simple mirror trap with peak magnetic field in the plug up to 2.5 T, mirror ratio of 3-5, and length variable from 15 to 20 cm. Plasma formed by a cathodic vacuum arc is injected into the trap either (i) axially using a compact vacuum arc plasma gun located on axis outside the mirror trap region or (ii) radially using four plasma guns surrounding the trap at midplane. Microwave heating of the mirror-confined, vacuum arc plasma is accomplished by gyrotron microwave radiation of frequency 75 GHz, power up to 200 kW, and pulse duration up to 150 micros, leading to additional stripping of metal ions by electron impact. Pulsed beams of platinum ions with charge state up to 10+, a mean charge state over 6+, and total (all charge states) beam current of a few hundred milliamperes have been formed.

  16. Limitations of electron cyclotron resonance ion source performances set by kinetic plasma instabilities.

    Science.gov (United States)

    Tarvainen, O; Laulainen, J; Komppula, J; Kronholm, R; Kalvas, T; Koivisto, H; Izotov, I; Mansfeld, D; Skalyga, V

    2015-02-01

    Electron cyclotron resonance ion source (ECRIS) plasmas are prone to kinetic instabilities due to anisotropy of the electron energy distribution function stemming from the resonant nature of the electron heating process. Electron cyclotron plasma instabilities are related to non-linear interaction between plasma waves and energetic electrons resulting to strong microwave emission and a burst of energetic electrons escaping the plasma, and explain the periodic oscillations of the extracted beam currents observed in several laboratories. It is demonstrated with a minimum-B 14 GHz ECRIS operating on helium, oxygen, and argon plasmas that kinetic instabilities restrict the parameter space available for the optimization of high charge state ion currents. The most critical parameter in terms of plasma stability is the strength of the solenoid magnetic field. It is demonstrated that due to the instabilities the optimum Bmin-field in single frequency heating mode is often ≤0.8BECR, which is the value suggested by the semiempirical scaling laws guiding the design of modern ECRISs. It is argued that the effect can be attributed not only to the absolute magnitude of the magnetic field but also to the variation of the average magnetic field gradient on the resonance surface.

  17. Limitations of electron cyclotron resonance ion source performances set by kinetic plasma instabilities

    Energy Technology Data Exchange (ETDEWEB)

    Tarvainen, O., E-mail: olli.tarvainen@jyu.fi; Laulainen, J.; Komppula, J.; Kronholm, R.; Kalvas, T.; Koivisto, H. [Department of Physics, University of Jyväskylä, 40500 Jyväskylä (Finland); Izotov, I.; Mansfeld, D. [Institute of Applied Physics, RAS, 46 Ul‘yanova St., 603950 Nizhny Novgorod (Russian Federation); Skalyga, V. [Institute of Applied Physics, RAS, 46 Ul‘yanova St., 603950 Nizhny Novgorod (Russian Federation); Lobachevsky State University of Nizhny Novgorod (UNN), 23 Gagarina St., 603950 Nizhny Novgorod (Russian Federation)

    2015-02-15

    Electron cyclotron resonance ion source (ECRIS) plasmas are prone to kinetic instabilities due to anisotropy of the electron energy distribution function stemming from the resonant nature of the electron heating process. Electron cyclotron plasma instabilities are related to non-linear interaction between plasma waves and energetic electrons resulting to strong microwave emission and a burst of energetic electrons escaping the plasma, and explain the periodic oscillations of the extracted beam currents observed in several laboratories. It is demonstrated with a minimum-B 14 GHz ECRIS operating on helium, oxygen, and argon plasmas that kinetic instabilities restrict the parameter space available for the optimization of high charge state ion currents. The most critical parameter in terms of plasma stability is the strength of the solenoid magnetic field. It is demonstrated that due to the instabilities the optimum B{sub min}-field in single frequency heating mode is often ≤0.8B{sub ECR}, which is the value suggested by the semiempirical scaling laws guiding the design of modern ECRISs. It is argued that the effect can be attributed not only to the absolute magnitude of the magnetic field but also to the variation of the average magnetic field gradient on the resonance surface.

  18. Comparison of different plasma chambers in microwave ion source for the intense neutron tube

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    The microwave absorption efficiency, which is relevant to magnet field and its distribution, is a major parameter of the microwave ion source (MWIS) for the intense neutron tube. Based on previous work, the relations between microwave absorption efficiency and plasma chamber structure and thickness of the microwave introduction window are studied. The microwave absorption efficiency reaches to 100% when plasma chamber is 100mm long and the window thickness is 30mm. The microwave absorption efficiency as a function of pressure is also presented.

  19. Determination of Clarithromycin in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Validation and Application in Clinical Pharmacokinetic Study

    Institute of Scientific and Technical Information of China (English)

    ZHANGXiang-rong; CHENXiao-yan; LIXiao-yan; ZHONGDa-fang

    2004-01-01

    Aim To develop a liquid chromatographic-tandem mass spectrometric (LC-MS-MS) method to determine clarithromycin in human plasma. Methods The analyte and internal standard roxithromycin were extracted from plasma samples by n-nexane-dichloromethane-isopropanel (300:150:15, V/V/V) and chromatographed on a C18 column. The mobile phase consisted of methanol-water-formic acid (80:20:1, V/V/V). Detection was performed on a triple quadrupole tandem mass spectrometer via electrospray ionization source (ESI) in the positive mode. Results The method had a lower limit of quantification of 10.0 ng·mL-1 when 0.2 mL plasma was used. The linear calibration curves were obtained in the concentration range of 10.0-5000 ng·mL-1. The intra-and inter-rum precisions were lower than 3.3% in terms of relative standard deviation (RSD), and the accuracy ranged±0.7% in terms of relative error (RE). Tmax, Cmax, T1/2 and AUC0-24h values were found to be (3.1±2.7)h, (8 750±4 734)ng·mL-1, (5.3±2.2)h, and (5932±2 449)ng·mL-1, respectively, after a single oral dose of 250 mg clarithromycin tablet to 18 volunteers. Conclusion This validated method was successful in the evaluation of pharmacokinetic profiles of clarithromycin tablets administered to 18 healthy male volubteers.

  20. Aluminium content of some processed foods, raw materials and food additives in China by inductively coupled plasma-mass spectrometry.

    Science.gov (United States)

    Deng, Gui-Fang; Li, Ke; Ma, Jing; Liu, Fen; Dai, Jing-Jing; Li, Hua-Bin

    2011-01-01

    The level of aluminium in 178 processed food samples from Shenzhen city in China was evaluated using inductively coupled plasma-mass spectrometry. Some processed foods contained a concentration of up to 1226 mg/kg, which is about 12 times the Chinese food standard. To establish the main source in these foods, Al levels in the raw materials were determined. However, aluminium concentrations in raw materials were low (0.10-451.5 mg/kg). Therefore, aluminium levels in food additives used in these foods was determined and it was found that some food additives contained a high concentration of aluminium (0.005-57.4 g/kg). The results suggested that, in the interest of public health, food additives containing high concentrations of aluminium should be replaced by those containing less. This study has provided new information on aluminium levels in Chinese processed foods, raw materials and a selection of food additives.

  1. Quantitative comparison of lipoprotein fractions derived from human plasma and serum by liquid chromatography-tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Collins Lisamarie A

    2010-07-01

    Full Text Available Abstract Background Lipoproteins are complex, globular molecules which play essential roles in the transport and metabolism of cholesterol. Their implication in the development of cardiovascular diseases, such as atherosclerosis, has sustained a great deal of interest in these particles. Their various functions, and their contribution to the development of atherosclerosis, are often attributed to their protein constituents, which vary greatly among the different lipoprotein classes. Recent advances in the field of mass spectrometry have provided insight into the array of proteins associated with low-density lipoproteins (LDLs and, even more so, with high-density lipoproteins (HDLs. Plasma and serum are the most commonly used samples for the analysis of lipoproteins. Although these lipoprotein sources are unique, it was our goal to determine whether or not their inherent differences would ultimately affect a quantitative analysis of the LDL and HDL proteomes. To this end, we isolated LDL and HDL fractions with fast protein liquid chromatography-size exclusion chromatography (FPLC-SEC from both human plasma and serum samples from the same individuals. After delipidating these samples, we performed a quantitative proteomic analysis to compare the lipoprotein-associated proteins derived from both plasma and serum. Results Although the primary differences between the samples are found in fibrinogen proteins which are removed from serum, it of interest to note that, with respect to LDL-associated proteins, apolipoproteinB-100 was found at significantly higher levels in serum samples. Complement component 3 was found at significantly higher levels in serum-derived HDL fractions. Both of these proteins are known LDL- and HDL-associated proteins, respectively. Conclusion Overall, the results from our study indicate that both plasma and serum samples are equally suited for proteomic studies, and provide similar results. These findings are particularly

  2. Magnetosphere-ionosphere coupling at Jupiter-like exoplanets with internal plasma sources: implications for detectability of auroral radio emissions

    CERN Document Server

    Nichols, J D

    2011-01-01

    In this paper we provide the first consideration of magnetosphere-ionosphere coupling at Jupiter-like exoplanets with internal plasma sources such as volcanic moons. We estimate the radio power emitted by such systems under the condition of near-rigid corotation throughout the closed magnetosphere, in order to examine the behaviour of the best candidates for detection with next generation radio telescopes. We thus estimate for different stellar X-ray-UV (XUV) luminosity cases the orbital distances within which the ionospheric Pedersen conductance would be high enough to maintain near-rigid corotation, and we then consider the magnitudes of the large-scale magnetosphere-ionosphere currents flowing within the systems, and the resulting radio powers, at such distances. We also examine the effects of two key system parameters, i.e. the planetary angular velocity and the plasma mass outflow rate from sources internal to the magnetosphere. In all XUV luminosity cases studied, a significant number of parameter combi...

  3. Characterization of Plasma Membrane Proteins from Ovarian Cancer Cells Using Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    David L. Springer

    2004-01-01

    Full Text Available To determine how the repertoire of plasma membrane proteins change with disease state, specifically related to cancer, several methods for preparation of plasma membrane proteins were evaluated. Cultured cells derived from stage IV ovarian tumors were grown to 90% confluence and harvested in buffer containing CHAPS detergent. This preparation was centrifuged at low speed to remove insoluble cellular debris resulting in a crude homogenate. Glycosylated proteins in the crude homogenate were selectively enriched using lectin affinity chromatography. The crude homogenate and the lectin purified sample were prepared for mass spectrometric evaluation. The general procedure for protein identification began with trypsin digestion of protein fractions followed by separation by reversed phase liquid chromatography that was coupled directly to a conventional tandem mass spectrometer (i.e. LCQ ion trap. Mass and fragmentation data for the peptides were searched against a human proteome data base using the informatics program SEQUEST. Using this procedure 398 proteins were identified with high confidence, including receptors, membrane-associated ligands, proteases, phosphatases, as well as structural and adhesion proteins. Results indicate that lectin chromatography provides a select subset of proteins and that the number and quality of the identifications improve as does the confidence of the protein identifications for this subset. These results represent the first step in development of methods to separate and successfully identify plasma membrane proteins from advanced ovarian cancer cells. Further characterization of plasma membrane proteins will contribute to our understanding of the mechanisms underlying progression of this deadly disease and may lead to new targeted interventions as well as new biomarkers for diagnosis.

  4. Bright X-ray source from a laser-driven micro-plasma-waveguide

    CERN Document Server

    Yi, Longqing

    2016-01-01

    Bright tunable x-ray sources have a number of applications in basic science, medicine and industry. The most powerful sources are synchrotrons, where relativistic electrons are circling in giant storage rings. In parallel, compact laser-plasma x-ray sources are being developed. Owing to the rapid progress in laser technology, very high-contrast femtosecond laser pulses of relativistic intensities become available. These pulses allow for interaction with micro-structured solid-density plasma without destroying the structure by parasitic pre-pulses. The high-contrast laser pulses as well as the manufacturing of materials at micro- and nano-scales open a new realm of possibilities for laser interaction with photonic materials at the relativistic intensities. Here we demonstrate, via numerical simulations, that when coupling with a readily available 1.8 Joule laser, a micro-plasma-waveguide (MPW) may serve as a novel compact x-ray source. Electrons are extracted from the walls by the laser field and form a dense ...

  5. Plasma diagnostics discharge parameters and chemistry

    CERN Document Server

    Auciello, Orlando

    1989-01-01

    Plasma Diagnostics, Volume 1: Discharge Parameters and Chemistry covers seven chapters on the important diagnostic techniques for plasmas and details their use in particular applications. The book discusses optical diagnostic techniques for low pressure plasmas and plasma processing; plasma diagnostics for electrical discharge light sources; as well as Langmuir probes. The text also describes the mass spectroscopy of plasmas, microwave diagnostics, paramagnetic resonance diagnostics, and diagnostics in thermal plasma processing. Electrical engineers, nuclear engineers, microwave engineers, che

  6. Chemical mass balance source apportionment of fine and PM10 in the Desert Southwest, USA

    Directory of Open Access Journals (Sweden)

    Andrea L. Clements

    2016-03-01

    Full Text Available The Desert Southwest Coarse Particulate Matter Study was undertaken in Pinal County, Arizona, to better understand the origin and impact of sources of fine and coarse particulate matter (PM in rural, arid regions of the U.S. southwestern desert. The desert southwest experiences some of the highest PM10 mass concentrations in the country. To augment previously reported results, 6-week aggregated organic speciation data that included ambient concentrations of n-alkanes, polycyclic aromatic hydrocarbons, organic acids, and saccharides were used in chemical mass balance modeling (CMB. A set of re-suspended soil samples were analyzed for specific marker species to provide locally-appropriate source profiles for the CMB analysis. These profiles, as well as previously collected plant and fungal spore profiles from the region, were combined with published source profiles for other relevant sources and used in the CMB analysis. The six new region-specific source profiles included both organic and inorganic species for four crustal material sources, one plant detritus source, and one fungal spore source.Results indicate that up to half of the ambient PM2.5 was apportioned to motor vehicles with the highest regional contribution observed in the small urban center of Casa Grande. Daily levels of apportioned crustal material accounted for up to 50% of PM2.5 mass with the highest contributions observed at the sites closest to active agricultural areas. Apportioned secondary PM, biomass burning, and road dust typically contributed less than 35% as a group to the apportioned PM2.5 mass. Crustal material was the primary source apportioned to PM10 and accounted for between 50–90% of the apportioned mass. Of the other sources apportioned to PM10, motor vehicles and road dust were the largest contributors at the urban and one of the rural sites, whereas road dust and meat cooking operations were the largest contributors at the other rural site.

  7. Electromagnetic radiation from filamentary sources in the presence of axially magnetized cylindrical plasma scatterers

    Energy Technology Data Exchange (ETDEWEB)

    Es’kin, V. A.; Ivoninsky, A. V.; Kudrin, A. V., E-mail: kud@rf.unn.ru; Popova, L. L. [Lobachevsky University (Russian Federation)

    2017-02-15

    Electromagnetic radiation from filamentary electric-dipole and magnetic-current sources of infinite length in the presence of gyrotropic cylindrical scatterers in the surrounding free space is studied. The scatterers are assumed to be infinitely long, axially magnetized circular plasma columns parallel to the axis of the filamentary source. The field and the radiation pattern of each source are calculated in the case where the source frequency is equal to one of the surface plasmon resonance frequencies of the cylindrical scatterers. It is shown that the presence of even a single resonant magnetized plasma scatterer of small electrical radius or a few such scatterers significantly affects the total fields of the filamentary sources, so that their radiation patterns become essentially different from those in the absence of scatterers or the presence of isotropic scatterers of the same shape and size. It is concluded that the radiation characteristics of the considered sources can efficiently be controlled using their resonance interaction with the neighboring gyrotropic scatterers.

  8. Liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source for elemental mass spectrometry: preliminary parametric evaluation and figures of merit.

    Science.gov (United States)

    Quarles, C Derrick; Carado, Anthony J; Barinaga, Charles J; Koppenaal, David W; Marcus, R Kenneth

    2012-01-01

    A new, low-power ionization source for the elemental analysis of aqueous solutions has recently been described. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) source operates at relatively low currents (LS-APGD has been interfaced to what is otherwise an organic, LC-MS mass analyzer, the Thermo Scientific Exactive Orbitrap without any modifications, other than removing the electrospray ionization source supplied with that instrument. A glow discharge is initiated between the surface of the test solution exiting a glass capillary and a metallic counter electrode mounted at a 90° angle and separated by a distance of ~5 mm. As with any plasma-based ionization source, there are key discharge operation and ion sampling parameters that affect the intensity and composition of the derived mass spectra, including signal-to-background ratios. We describe here a preliminary parametric evaluation of the roles of discharge current, solution flow rate, argon sheath gas flow rate, and ion sampling distance as they apply on this mass analyzer system. A cursive evaluation of potential matrix effects due to the presence of easily ionized elements indicate that sodium concentrations of up to 50 μg mL(-1) generally cause suppressions of less than 50%, dependant upon the analyte species. Based on the results of this series of studies, preliminary limits of detection (LOD) have been established through the generation of calibration functions. While solution-based concentration LOD levels of 0.02-2 μg mL(-1) are not impressive on the surface, the fact that they are determined via discrete 5 μL injections leads to mass-based detection limits at picogram to single-nanogram levels. The overhead costs associated with source operation (10 W d.c. power, solution flow rates of LS-APGD ion source may present a practical alternative to inductively coupled plasma sources typically employed in elemental mass spectrometry.

  9. A numerical simulation of surface wave excitation in a rectangular planar-type plasma source

    Institute of Scientific and Technical Information of China (English)

    Chen Zhao-Quan; Liu Ming-Hai; Lan Chao-Hui; Chen Wei; Tang Liang; Luo Zhi-Qing; Yan Bao-Rong; Lu Jian-Hong; Hu Xi-Wei

    2009-01-01

    The principle of surface wave plasma discharge in a rectangular cavity is introduced simply based on surface plasmon polariton theory.The distribution of surface-wave electric field at the interface of the plasma-dielectric slab is investigated by using the three-dimensional finite-difference time-domain method (3D-FDTD) with different slotantenna structures.And the experimental image of discharge with a novel slot antenna array and the simulation of the electric field with this slot antenna array are both displayed.Combined with the distribution of surface wave excitation and experimental results,the numerical simulation performed by using 3D-FDTD is shown to be a useful tool in the computer-aided antenna design for large area planar-type surface-wave plasma sources.

  10. Unstable plasma characteristics in mirror field electron cyclotron resonance microwave ion source

    Indian Academy of Sciences (India)

    S K Angra; Parshant Kumar; R R Dongaonkar; R P Bajpai

    2000-05-01

    Electron cyclotron plasma reactor are prone to instabilities in specific input power [3–7] region (150–450 watts). In this region power absorption by gas molecules in the cavity is very poor and enhanced input power gets reflected substantially without increasing ion density. There are abrupt changes in plasma characteristics when input power was decreased from maximum to minimum, it was observed that reflected power changed from < 2% to ∼ 50%. Minimum two jumps in reflected power were noticed in this specific power region and these appear to be highly sensitive to three stub tuner position in the waveguide for this particular input power zone. Unstable plasma region of this source is found to be dependent upon the magnetic field strength. Some changes in reflected power are also noticed with pressure, flow and bias and they are random in nature.

  11. Conformal doping of topographic silicon structures using a radial line slot antenna plasma source

    Science.gov (United States)

    Ueda, Hirokazu; Ventzek, Peter L. G.; Oka, Masahiro; Horigome, Masahiro; Kobayashi, Yuuki; Sugimoto, Yasuhiro; Nozawa, Toshihisa; Kawakami, Satoru

    2014-06-01

    Fin extension doping for 10 nm front end of line technology requires ultra-shallow high dose conformal doping. In this paper, we demonstrate a new radial line slot antenna plasma source based doping process that meets these requirements. Critical to reaching true conformality while maintaining fin integrity is that the ion energy be low and controllable, while the dose absorption is self-limited. The saturated dopant later is rendered conformal by concurrent amorphization and dopant containing capping layer deposition followed by stabilization anneal. Dopant segregation assists in driving dopants from the capping layer into the sub silicon surface. Very high resolution transmission electron microscopy-Energy Dispersive X-ray spectroscopy, used to prove true conformality, was achieved. We demonstrate these results using an n-type arsenic based plasma doping process on 10 to 40 nm high aspect ratio fins structures. The results are discussed in terms of the different types of clusters that form during the plasma doping process.

  12. Influence of ion species ratio on grid-enhanced plasma source ion implantation

    Institute of Scientific and Technical Information of China (English)

    Wang Jiu-Li; Zhang Gu-Ling; Liu Yuan-Fu; Wang You-Nian; Liu Chi-Zi; Yang Si-Ze

    2004-01-01

    @@ Grid-enhanced plasma source ion implantation (GEPSII) is a newly proposed technique to modify the inner-surface properties of a cylindrical bore. In this paper, a two-ion fluid model describing nitrogen molecular ions N2+ and atomic ions N+ is used to investigate the ion sheath dynamics between the grid electrode and the inner surface of a cylindrical bore during the GEPSII process, which is an extension of our previous calculations in which only N2+ was considered.Calculations are concentrated on the results of ion dose and impact energy on the target for different ion species ratios in the core plasma. The calculated results show that more atomic ions N+ in the core plasma can raise the ion impact energy and reduce the ion dose on the target.

  13. New high temperature plasmas and sample introduction systems for analytical atomic emission and mass spectrometry

    Science.gov (United States)

    Montaser, A.

    This research follows a multifaceted approach, from theory to practice, to the investigation and development of novel helium plasmas, sample introduction systems, and diagnostic techniques for atomic and mass spectrometries. During the period January 1994 - December 1994, four major sets of challenging research programs were addressed that each included a number of discrete but complementary projects: (1) The first program is concerned with fundamental and analytical investigations of novel atmospheric-pressure helium inductively coupled plasmas (He ICPS) that are suitable for the atomization-excitation-ionization of elements, especially those possessing high excitation and ionization energies, for the purpose of enhancing sensitivity and selectivity of analytical measurements. (2) The second program includes simulation and computer modeling of He ICPS. The aim is to ease the hunt for new helium plasmas by predicting their structure and fundamental and analytical properties, without incurring the enormous cost for extensive experimental studies. (3) The third program involves spectroscopic imaging and diagnostic studies of plasma discharges to instantly visualize their prevailing structures, to quantify key fundamental properties, and to verify predictions by mathematical models. (4) The fourth program entails investigation of new, low-cost sample introduction systems that consume micro- to nanoliter quantity of sample solution in plasma spectrometries. A portion of this research involves development and applications of novel diagnostic techniques suitable for probing key fundamental properties of aerosol prior to and after injection into high-temperature plasmas. These efforts, still in progress, collectively offer promise of solving singularly difficult analytical problems that either exist now or are likely to arise in the future in the various fields of energy generation, environmental pollution, material science, biomedicine and nutrition.

  14. Nitrogen mass transfer models for plasma-based low-energy ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Bocong; Wang, Kesheng; Zhang, Zhipeng; Che, Honglong; Lei, Mingkai, E-mail: mklei@dlut.edu.cn [Surface Engineering Laboratory, School of Materials Science and Engineering, Dalian University of Technology, Dalian 116024 (China)

    2015-03-15

    The nitrogen mass transfer process in plasma-based low-energy ion implantation (PBLEII) is theoretically and experimentally studied in order to explore the process mechanism of PBLEII and therefore to optimize the apparatus design and the process conditions. An electron cyclotron resonance (ECR) microwave discharge generates the nitrogen plasma with a high density of 10{sup 11}–10{sup 12} ions/cm{sup 3}, which diffuses downstream to the process chamber along the divergent magnetic field. The nitrogen ions in the plasma implant into the surface and transport to the matrix of an austenitic stainless steel under the low negative pulsed bias of −2 kV at a process temperature of 400 °C. A global plasma model is used to simulate the ECR microwave plasma discharge for a range of working pressures and microwave powers. The fluid models are adopted to calculate the plasma downstream diffusion, the sheath expansion and the low-energy ion implantation on the surface. A nonlinear kinetic discrete model is established to describe the nitrogen transport in the austenitic stainless steel and the results are compared with the experimental measurements. Under an average implantation current density of 0.3–0.6 mA/cm{sup 2}, the surface nitrogen concentration in the range from 18.5 to 29 at. % is a critical factor for the nitrogen transport in the AISI 304 austenitic stainless steel by PBLEII, which accelerates the implanted nitrogen diffusion inward up to 6–12 μm during a nitriding time of 4 h.

  15. Quantification of {sup 232}Th, {sup 234}U, {sup 235}U and {sup 238}U in river mollusks by magnetic sector mass spectrometry with inductively coupled plasma source (Icp-SFMS); Cuantificacion de {sup 232}Th, {sup 234}U, {sup 235}U y {sup 238}U en moluscos de rios por espectrometria de masas de sector magnetico con fuente de plasma acoplado inductivamente (ICP-SFMS)

    Energy Technology Data Exchange (ETDEWEB)

    Arevalo R, D. L.; Hernandez M, H.; Romero G, E. T.; Lara A, N. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Alfaro de la T, M. C., E-mail: arevalo0591@hotmail.com [Universidad Autonoma de San Luis Potosi, Dr. Salvador Nava s/n, Zona Universitaria, 78290 San Luis Potosi, SLP (Mexico)

    2016-09-15

    The present work deals with the methodology established for the quantification of {sup 232}Th, {sup 234}U, {sup 238}U and {sup 235}U in the shell of gastropod mollusks collected in the rivers Valles, Coy and Axtla of San Luis Potosi, Mexico, which belong to the Panuco River basin; these rivers have as main source of pollution the discharge of municipal sewage, waste from small industries, agricultural and cattle residues and from natural sources. Conventional methods for measuring radio-nuclides are confronted with certain conditions related to the requirement in measurement, basically in the characterization that is related to the concepts of precision and accuracy. The analysis of the gastropod mollusk shell was performed by the Icp-SFMS technique; the main advantages of this technique lie in the isotope quantification capacity, the high precision and the low limits of detection, in this study are very important because these elements are in concentrations between ppb and ppt. This technique allowed the analysis of the samples having a complex matrix by the presence CaCO{sub 3} minimizing the interferences thanks to the ionization efficiency of the Ar plasma. For the species Pachychilus monachus were found concentrations of {sup 232}Th of 0.16-5.37 μg/g and of total U of 0.101-4.081 μg/g being this species where the highest values of total U were found. For Thiara (melanoids) tuberculata the lowest values were found among the different species ({sup 232}Th 0.61-3.61 μg/g and total U 0.006-0.042 μg/g), for Pachychilus suturalis, values of {sup 232}Th of 0.58-6.4 μg/g and for Pachychilus sp. were found between 0.26-7.62 μg/g and for total U values between 0.28-3.33 μg/g. The method offers several advantages: speed, good precision, low values of quantification limits and high sensitivity in the measurement of radio-nuclides and heavy metals. (Author)

  16. Determination of moxonidine in human plasma by liquid chromatography-electrospray ionisation-mass spectrometry.

    Science.gov (United States)

    Zhao, Luhua; Ding, Li; Wei, Xin

    2006-01-23

    A sensitive and specific liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and quantification of moxonidine in human plasma. After the addition of clonidine-HCl, the internal standard (IS) and sodium hydrogen carbonate, plasma samples were extracted using 5 mL ethyl acetate. The compounds were separated on a Lichrospher ODS (5 microm, 250 mm x 4.6 mm) column using an elution system of 10 mmol/L ammonium acetate buffer-methanol (20:80 v/v) as the mobile phase. Analytes were determined using electrospary ionization in a single quadrupole mass spectrometer. LC-ESI-MS was performed in the selected-ion monitoring (SIM) mode using target ions at m/z: 242.2 for moxonidine and m/z: 230.1 for the IS. The method has shown to be sensitive and specific by testing six different blank plasma batches. Linearity was established for the range of concentrations 0.01976-9.88 ng/mL with a coefficient of correlation (r) of 0.9999. The lower limit of quantification (LOQ) was identifiable and reproducible at 0.01976 ng/mL. The method has been successfully applied to study the pharmacokinetics of moxonidine in healthy male Chinese volunteers.

  17. Determination of doxepin and desmethyldoxepin in human plasma using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Badenhorst, D; Sutherland, F C; de Jager, A D; Scanes, T; Hundt, H K; Swart, K J; Hundt, A F

    2000-05-26

    A sensitive method for the simultaneous determination of doxepin and its active metabolite desmethyldoxepin in plasma was established, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. The samples were extracted with hexane-isoamyl alcohol, separated on a Phenomenex Luna C18 5 microm, 150x2.1 mm column with a mobile phase consisting of methanol-water-formic acid (600:400:0.5, v/v) at a flow-rate of 0.25 ml/min. Detection was achieved by a Perkin-Elmer API 2000 mass spectrometer at unit resolution in multiple reaction monitoring mode monitoring the transition of the protonated molecular ions m/z 280.2, 266.2 and 250.1 to the product ions m/z 107.1, 107.1 and 191.0 for analyte, metabolite and internal standard (benzoctamine-HCl), respectively. TurbolonSpray ionisation was used for ion production. The mean recovery for doxepin and desmethyldoxepin was 90% and 75%, respectively, with a lower limit of quantification at 0.320 ng/ml and 0.178 ng/ml for the analyte and its metabolite, respectively, using 0.5 ml plasma for extraction. This is the first assay method described for the simultaneous determination of doxepin and desmethyldoxepin in plasma using LC-MS-MS. The method is sensitive enough to be used in drug bioavailability studies with doxepin.

  18. Determination of tolperisone in human plasma by liquid chromatography/tandem mass spectrometry for clinical application.

    Science.gov (United States)

    Choi, Chang-Ik; Park, Jung-In; Lee, Hye-In; Lee, Yun-Jeong; Jang, Choon-Gon; Bae, Jung-Woo; Lee, Seok-Yong

    2012-12-12

    We have developed and validated a simple, rapid, and sensitive liquid chromatography analytical method employing tandem mass spectrometry (LC-MS/MS) for the determination of tolperisone, a centrally acting muscle relaxant, in human plasma. After liquid-liquid extraction with methyl t-butyl ether, chromatographic separation of tolperisone was performed using a reversed-phase Luna C(18) column (2.0mm×50mm, 5μm particles) with a mobile phase of 10mM ammonium formate buffer (pH 3.5) - methanol (12:88, v/v) and quantified by tandem mass detection in ESI positive ion mode. The flow rate of the mobile phase was 250μL/min and the retention times of tolperisone and the internal standard (IS, dibucaine) were both 0.6min. The calibration curves were linear over a range of 0.5-300ng/mL (r>0.999). The lower limit of quantification, using 200μL human plasma, was 0.5ng/mL. The mean accuracy and precision for intra- and inter-day validation of tolperisone were within acceptable limits. The LC-MS/MS method reported here showed improved sensitivity for quantification of tolperisone in human plasma compared with previously described analytical methods. Lastly, the validated method was successfully applied to a pharmacokinetic study in humans.

  19. Reference masses for precision mass spectrometry design and implementation of a Pierce geometry to the cluster Ion source at ISOLTRAP

    CERN Document Server

    Lommen, Jonathan

    At the mass spectrometer ISOLTRAP carbon clusters ($^{12}$Cn, 1$\\leqslant$n$\\leqslant$25) are provided as reference masses, which are of particular importance in higher mass ranges (m $\\geqslant$ 200u). In this mass range the measurlment uncertainty is increasingly dominated by the difference of the reference mass and the mass of the ion of interest. Using carbon clusters instead of the common $^{133}$Cs ions, this difference decreases. The carbon clusters are produced in a laser ion source which has been improved in the frame of this thesis. The fluctuations of the count rate have been investigated as a function of the laser energy. Furthermore, the energy density at the target has been increased by implementation of a telescope into the laser beam line, which leads to a more narrow energy distribution of the ions. Through the exact adjustment of timing and length of a pulsed cavity an energy range with constant count rate could be selected. In order to provide ideal starting conditions during and after the ...

  20. Multi-Modality Pulsed AC Source for Medical Applications of Non-Equilibrium Plasmas

    Science.gov (United States)

    Friedrichs, Daniel; Gilbert, James

    2014-10-01

    A burgeoning field has developed around the use of non-equilibrium (``cold'') plasmas for various medical applications, including wound treatment, surface sterilization, non-thermal hemostasis, and selective cell destruction. Proposed devices typically utilize pulsed DC power sources, which have no other therapeutic utility, and may encounter significant regulatory restrictions regarding their safety for use in patient care. Additionally, dedicated capital equipment is difficult for healthcare facilities to justify. In this work, we have demonstrated for the first time the generation of non-equilibrium plasma using pulsed AC output from a specially-designed electrosurgical generator. The ability to power novel non-equilibrium plasma devices from a piece of equipment already ubiquitous in operating theatres should significantly reduce the barriers to adoption of plasma devices. We demonstrate the ability of a prototype device, coupled to this source, to reduce bacterial growth in vitro. Such a system could allow a single surgical instrument to provide both non-thermal sterilization and thermal tissue dissection.

  1. Simultaneous determination of irbesartan and hydrochlorothiazide in human plasma by ultra high performance liquid chromatography tandem mass spectrometry and its application to a bioequivalence study.

    Science.gov (United States)

    Qiu, Xiangjun; Wang, Zhe; Wang, Bing; Zhan, Hui; Pan, Xiaofeng; Xu, Ren-ai

    2014-04-15

    An ultra high performance liquid chromatography tandem mass spectrometry (U-HPLC-MS/MS) method was developed and validated to determine irbesartan (IRB) and hydrochlorothiazide (HCTZ) in human plasma simultaneously. Plasma samples were prepared using protein precipitation with acetonitrile, the two analytes and the internal standard losartan were separated on an Acquity U-HPLC BEH C18 column and mass spectrometric analysis was performed using a QTrap5500 mass spectrometer coupled with an electro-spray ionization (ESI) source in the negative ion mode. The MRM transitions of m/z 427.2→206.9 and m/z 296.1→204.9 were used to quantify for IRB and HCTZ, respectively. The linearity of this method was found to be within the concentration range of 5-3000ng/mL for IRB, and 0.5-300ng/mL for HCTZ in human plasma, respectively. The lower limit of quantification (LLOQ) was 5ng/mL and 0.5ng/mL for IRB and HCTZ in human plasma, respectively. The relative standard deviations (RSD) of intra and inter precision were less than 12% for both IRB and HCTZ. The analysis time of per sample was 2.5min. The developed and validated method was successfully applied to a bioequivalence study of IRB (300mg) with HCTZ (12.5mg) tablet in Chinese healthy volunteers (N=20).

  2. Extreme Ultraviolet Light Emission from Z-Pinch Discharge Plasma Source

    Science.gov (United States)

    Watanabe, Masato; Song, Inho; Sakamoto, Toshiro; Kobayashi, Yasunori; Okino, Akitoshi; Mohanty, Smruti R.; Horioka, Kazuhiko; Hotta, Eiki

    2006-01-01

    A capillary Z-pinch discharge light source for EUV lithography has been developed. Our device is equipped with a water-cooled ceramic capillary and electrodes, and a solid state pulsed power generator. A stacked static induction thyristors are used as switching elements, which enable high repetition rate operation of pulsed power supply. A magnetic switch is connected in series, which not only assists the semiconductor switch but also provides a preionization current. In the present study, EUV radiation emitted from pinching plasma in a xenon-filled capillary was quantitatively measured using an in-band calorimeter. Time-integrated in-band source image was also observed using a pinhole camera system. Furthermore, new electrode system using plasma jet has been developed.

  3. Inductively driven surface-plasma negative ion source for N-NBI use (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Belchenko, Yu., E-mail: belchenko@inp.nsk.su; Abdrashitov, G.; Deichuli, P.; Ivanov, A.; Gorbovsky, A.; Kondakov, A.; Sanin, A.; Sotnikov, O.; Shikhovtsev, I. [Budker Institute of Nuclear Physics, Siberian Branch of Russian Academy of Sciences, Novosibirsk (Russian Federation)

    2016-02-15

    The long-pulse surface-plasma source prototype is developed at Budker Institute of Nuclear Physics for negative-ion based neutral beam injector use. The essential source features are (1) an active temperature control of the ion-optical system electrodes by circulation of hot thermal fluid through the channels, drilled in the electrode bodies, (2) the concaved transverse magnetic field in the extraction and acceleration gaps, preventing the electrons trapping and avalanching, and (3) the directed cesium deposition via distribution tubes adjacent to the plasma grid periphery. The long term effect of cesium was obtained just with the single cesium deposition. The high voltage strength of ion-optical system electrodes was improved with actively heated electrodes. A stable H{sup −} beam with a current ∼1 A and energy 90 keV was routinely extracted and accelerated.

  4. SiC detectors for radiation sources characterization and fast plasma diagnostic

    Science.gov (United States)

    Cannavò, A.; Torrisi, L.

    2016-09-01

    Semiconductor detectors based on SiC have been investigated to characterize the radiations (photons and particles) emitted from different sources, such as radioactive sources, electron guns, X-ray tubes and laser-generated plasmas. Detectors show high response velocity, low leakage current, high energy gap and high radiation hardness. Their high detection efficiency permits to use the detectors in spectroscopic mode and in time-of-flight (TOF) approach, generally employed to monitor low and high radiation fluxes, respectively. Using the laser start signal, they permit to study the properties of the generated plasma in vacuum by measuring accurately the particle velocity and energy using pulsed lasers at low and high intensities. Possible applications will be reported and discussed.

  5. DBD plasma source operated in single-filamentary mode for therapeutic use in dermatology

    Science.gov (United States)

    Rajasekaran, Priyadarshini; Mertmann, Philipp; Bibinov, Nikita; Wandke, Dirk; Viöl, Wolfgang; Awakowicz, Peter

    2009-11-01

    Our dielectric barrier discharge (DBD) plasma source for bio-medical application comprises a copper electrode covered with ceramic. Objects of high capacitance such as the human body can be used as the opposite electrode. In this study, the DBD source is operated in single-filamentary mode using an aluminium spike as the opposite electrode, to imitate the conditions when the discharge is ignited on a raised point, such as hair, during therapeutic use on the human body. The single-filamentary discharge thus obtained is characterized using optical emission spectroscopy, numerical simulation, voltage-current measurements and microphotography. For characterization of the discharge, averaged plasma parameters such as electron distribution function and electron density are determined. Fluxes of nitric oxide (NO), ozone (O3) and photons reaching the treated surface are simulated. The calculated fluxes are finally compared with corresponding fluxes used in different bio-medical applications.

  6. Detection of metals and metalloproteins in the plasma of stroke patients by mass spectrometry methods.

    Science.gov (United States)

    Kodali, Phanichand; Chitta, Karnakar R; Landero Figueroa, Julio A; Caruso, Joseph A; Adeoye, Opeolu

    2012-10-01

    Stroke is the leading cause of adult disability, worldwide. Metalloproteins and metals play key roles in epigenetic events in living organisms, including hypertension, the most important modifiable risk factor for stroke. Thus, metalloproteins may be important target biomarkers for disease diagnosis. The primary goal of this study was to assess metal containing proteins in blood plasma, detected by ICP-MS, followed by ESIMS for peptide/protein identification. We then compared the relative concentration differences between samples from patients with ischemic stroke, hemorrhagic stroke and stroke mimics. In 29 plasma samples (10 stroke mimics, 10 ischemic stroke and 9 hemorrhagic stroke patients) previously collected from patients who presented to the University of Cincinnati Emergency Department within 12 hours of symptom onset for a plasma banking project. For the metal associated protein study, Mg, Mn, Cu, Se concentrations were statistically different when compared between stroke mimics vs. ischemic stroke patients and ischemic stroke patients vs. hemorrhagic stroke patients. Pb concentrations were statistically different when compared between stroke mimics vs. ischemic stroke patients and Mo levels were statistically the same among the three groups. In addition, we also report concentration levels and preliminary correlation studies for total elemental analysis among the three sets of patients. This pilot study demonstrates that mass spectrometry methods may be highly valuable in detecting novel stroke biomarkers in blood plasma. Expanded studies are warranted to confirm these findings.

  7. Langmuir Probe and Mass Spectroscopic Measurements in Inductively Coupled CF4 Plasmas

    Science.gov (United States)

    Rao, M. V. V. S.; Sharma, Surendra; Cruden, B. A.; Meyyappan, M.

    2001-01-01

    Abstract Electron and ion energy distribution functions and other plasma parameters such as plasma potential (V(sub p)) , electron temperature (T(sub e)), and electron and ion number densities (n (sub e) and n(sub i)) in low pressure CF4 plasmas have been measured. The experiments were conducted in a GEC cell using an inductively coupled plasma (ICP) device powered by a 13.56 MHz radio-frequency (rf) power source. The measurements were made at 300 W of input rf power at 10, 30 and 50 mTorr gas pressures. Langmuir probe measurements suggest that n(sub e), n(sub i) and V(sub p) remain constant over 60% of the central electrode area, beyond which they decrease. Within the limits of experimental error (+/- 0.25 eV), T(sub e) remains nearly constant over the electrode area. T(sub e) and V(sub p) increase with a decrease in pressure. n(sub e) and n(sub i) are not affected as significantly as T(sub e) or V(sub p) by variation in the gas pressure. The electron energy distribution function (EEDF) measurements indicate a highly non-Maxwellian plasma. CF3+ is the most dominant ion product of the plasma, followed by CF2+ and CF+. The concentrations of CF2+ and CF+ are much larger than that is possible from direct electron impact ionization of the parent gas. The cross-section data suggest that the direct electron impact ionization of fragment neutrals and negative ion production by electron attachment may be responsible for increase of the minor ions.

  8. Chromospheric Nanoflares as a Source of Coronal Plasma: II. Repeating Nanoflares

    CERN Document Server

    Bradshaw, Stephen J

    2016-01-01

    The million degree plasma of the solar corona must be supplied by the underlying layers of the atmosphere. The mechanism and location of energy release, and the precise source of coronal plasma, remain unresolved. In earlier work we pursued the idea that warm plasma is supplied to the corona via direct heating of the chromosphere by nanoflares, contrary to the prevailing belief that the corona is heated in-situ and the chromosphere is subsequently energized and ablated by thermal conduction. We found that single (low-frequency) chromospheric nanoflares could not explain the observed intensities, Doppler-shifts, and red/blue asymmetries in Fe XII and XIV emission lines. In the present work we follow up on another suggestion that the corona could be powered by chromospheric nanoflares that repeat on a timescale substantially shorter than the cooling/draining timescale. That is, a single magnetic strand is re-supplied with coronal plasma before the existing plasma has time to cool and drain. We perform a series ...

  9. The dispersion and matching characteristics of the helical resonator plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Niazi, K.; Lichtenberg, A.J.; Lieberman, M.A. [Univ. of California, Berkeley, CA (United States)

    1995-10-01

    The dispersion characteristics and the fields of a helical resonator are obtained. The coil is approximated by a helical current layer with infinite conductivity along the current direction (a ``sheath helix``). The plasma column is modeled as a cylindrical dielectric in which the dielectric losses can be neglected in determining the propagation properties of the resonator. Assuming the plasma losses are known, the model can be used to study the matching of the helical resonator to an external power source which is connected to the helix by a tap. The resonator is modeled as a parallel connection of two transmission line segments on each side of the tap position. The authors determine the efficiency of power transfer to the resonator as a function of the tap position driving frequency, and plasma loading. They find that whereas for a small plasma loading it is possible to achieve perfect matching, there exists a critical value of plasma loading beyond which a perfect match is no longer possible.

  10. Effect of Wall Material on H– Production in a Plasma Sputter-Type Ion Source

    Directory of Open Access Journals (Sweden)

    Y. D. M. Ponce

    2004-12-01

    Full Text Available The effect of wall material on negative hydrogen ion (H– production was investigated in a multicusp plasma sputter-type ion source (PSTIS. Steady-state cesium-seeded hydrogen plasma was generated by a tungsten filament, while H– was produced through surface production using a molybdenum sputter target. Plasma parameters and H– yields were determined from Langmuir probe and Faraday cup measurements, respectively. At an input hydrogen pressure of 1.2 mTorr and optimum plasma discharge parameters Vd = –90 V and Id = –2.25 A, the plasma parameters ne was highest and T–e was lowest as determined from Langmuir probe measurements. At these conditions, aluminum generates the highest ion current density of 0.01697 mA/cm2, which is 64% more than the 0.01085 mA/cm2 that stainless steel produces. The yield of copper, meanwhile, falls between the two materials at 0.01164 mA/cm2. The beam is maximum at Vt = –125 V. Focusing is achieved at VL = –70 V for stainless steel, Vt = –60 V for aluminum, and Vt = –50 V for copper. The results demonstrate that proper selection of wall material can greatly enhance the H– production of the PSTIS.

  11. Lead concentrations and isotope ratios in street dust determined by electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Nageotte, S M; Day, J P

    1998-01-01

    A major source of environmental lead, particularly in urban areas, has been from the combustion of leaded petrol. Street dust has previously been used to assess urban lead contamination, and the dust itself can also be a potential source of lead ingestion, particularly to children. The progressive reduction of lead in petrol, in recent years, would be expected to have been reflected in a reduction of lead in urban dust. We have tested this hypothesis by repeating an earlier survey of Manchester street dust and carrying out a comparable survey in Paris. Samples were collected from streets and parks, lead was extracted by digestion with concentrated nitric acid and determined by electrothermal atomic absorption spectrometry. Lead isotope ratios were measured by inductively coupled plasma mass spectrometry. Results for Manchester show that lead concentrations have fallen by about 40% (street dust averages, 941 micrograms g-1 (ppm) in 1975 down to 569 ppm in 1997). In Paris, the lead levels in street dust are much higher and significant differences were observed between types of street (not seen in Manchester). Additionally, lead levels in parks were much lower than in Manchester. Samples collected under the Eiffel Tower had very high concentrations and lead isotope ratios showed that this was unlikely to be fallout from motor vehicles but could be due to the paint used on the tower. Isotope ratios measurements also revealed that lead additives used in France and the UK come from different sources.

  12. Chemical Ionization Mass Spectrometry Using Carbon Nanotube Field Emission Electron Sources

    Science.gov (United States)

    Radauscher, Erich J.; Keil, Adam D.; Wells, Mitch; Amsden, Jason J.; Piascik, Jeffrey R.; Parker, Charles B.; Stoner, Brian R.; Glass, Jeffrey T.

    2015-11-01

    A novel chemical ionization (CI) source has been developed based on a carbon nanotube (CNT) field emission electron source. The CNT-based electron source was evaluated and compared with a standard filament thermionic electron source in a commercial explosives trace detection desktop mass spectrometer. This work demonstrates the first reported use of a CNT-based ion source capable of collecting CI mass spectra. Both positive and negative modes were investigated. Spectra were collected for a standard mass spectrometer calibration compound, perfluorotributylamine (PFTBA), as well as trace explosives including trinitrotoluene (TNT), Research Department explosive (RDX), and pentaerythritol tetranitrate (PETN). The electrical characteristics, lifetime at operating pressure, and power requirements of the CNT-based electron source are reported. The CNT field emission electron sources demonstrated an average lifetime of 320 h when operated in constant emission mode under elevated CI pressures. The ability of the CNT field emission source to cycle on and off can provide enhanced lifetime and reduced power consumption without sacrificing performance and detection capabilities.

  13. Operational and theoretical temperature considerations in a Penning surface plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Faircloth, D. C., E-mail: dan.faircloth@stfc.ac.uk; Lawrie, S. R. [ISIS Neutron and Muon Facility, STFC Rutherford Appleton Laboratory, Harwell Oxford, OX11 0QX (United Kingdom); Pereira Da Costa, H. [CERN, Geneva (Switzerland); Dudnikov, V. [Muons Inc. United States of America (United States)

    2015-04-08

    A fully detailed 3D thermal model of the ISIS Penning surface plasma source is developed in ANSYS. The proportion of discharge power applied to the anode and cathode is varied until the simulation matches the operational temperature observations. The range of possible thermal contact resistances are modelled, which gives an estimation that between 67% and 85% of the discharge power goes to the cathode. Transient models show the electrode surface temperature rise during the discharge pulse for a range of duty cycles. The implications of these measurements are discussed and a mechanism for governing cesium coverage proposed. The requirements for the design of a high current long pulse source are stated.

  14. A study on vacuum aspects of electron cyclotron resonance ion source plasma

    Science.gov (United States)

    Ghosh, S.; Taki, G. S.; Mallick, C.; Bhandari, R. K.

    2008-05-01

    The electron cyclotron resonance (ECR) ion source is special type hot plasma machine where the high temperature electrons co-exist with multiply charge state ions and neutrals. A few years ago 6.4 GHz. ECR ion source (VEC-ECR) was developed indigenously at VECC. This multiply charged ion source is being used continuously to inject heavy ion beams into the cyclotron. Vacuum plays the major role in ECR ion source. The water cooled plasma chamber is made from an oxygen free high conductivity copper billet to meet the suitable surface condition for vacuum purpose. The entire volume of the ion source is pumped by two 900 1/s special type oil diffusion pumps to achieve 5×10-8 Torr. Usually main plasma chamber is pumped by the plasma itself. Moreover a few 1/s additional pumping speed is provided through extraction hole and pumping slot on the extraction electrode. A study has been carried out to understand the role of vacuum on the multiply charged heavy ion production process. Considering the ion production and loss criteria, it is seen that for getting Ar18+ better vacuum is essential for lower frequency operation. So, an ECR ion source can give better charge state current output operating at higher frequency and stronger confining magnetic field under a specific vacuum condition. The low pressure condition is essential to minimize charge exchange loss due to recombination of multiply charged ions with the neutral atoms. A fixed ratio of neutral to electron density must be maintained for optimizing a particular charge state in the steady state condition. As the electron density is proportional to square of the injected microwave frequency (nevpropf2) a particular operating pressure is essential for a specific charge state. From the study, it has been obtained that the production of Ar18+ ions needs a pressure ~ 9.6×10-8 Torr for 6.4 GHz. ECR ion source. It is also obtained that an ECR ion source, works at a particular vacuum level, can give better charge state

  15. Source Apportionment of Ambient PM10 in the Urban Area of Longyan City, China: a Comparative Study Based on Chemical Mass Balance Model and Factor Analysis Method

    Institute of Scientific and Technical Information of China (English)

    QIU Li-min; LIU Miao; WANG Ju; ZHANG Sheng-nan; FANG Chun-sheng

    2012-01-01

    In order to identify the day and night pollution sources of PM10 in ambient air in Longyan City,the authors analyzed the elemental composition of respirable particulate matters in the day and night ambient air samples and various pollution sources which were collected in January 2010 in Longyan with inductivity coupled plasma-mass spectrometry(ICP-MS).Then chemical mass balance(CMB)model and factor analysis(FA)method were applied to comparatively study the inorganic components in the sources and receptor samples.The results of factor analysis show that the major sources were road dust,waste incineration and mixed sources which contained automobile exhaust,soil dust/secondary dust and coal dust during the daytime in Longyan City,China.There are two major sources of pollution which are soil dust and mixture sources of automobile exhaust and secondary dust during the night in Longyan.The results of CMB show that the major sources are secondary dust,automobile exhaust and road dust during the daytime in Longyan.The major sources are secondary dust,soil dust and automobile exhaust during the night in Longyan.The results of the two methods are similar to each other and the results will guide us to plan to control the PM10 pollution sources in Longyan.

  16. Radio frequency plasma polymer coatings for affinity capture MALDI mass spectrometry.

    Science.gov (United States)

    Li, Meiling; Timmons, Richard B; Kinsel, Gary R

    2005-01-01

    Surface modification of MALDI probes is an attractive approach for combining bioaffinity isolation of targeted biomolecules with mass spectrometric analysis of the captured species. In this work, we demonstrate that a polymer thin film, produced by pulsed rf plasma polymerization of allylamine and deposited directly on a MALDI probe, can be subsequently biotinylated to develop a bioaffinity capture MALDI probe. The synthesis and characterization of the probe by XPS, FT-IR, and AFM is described, and the selective isolation of avidin from a three-component mixture of avidin, lysozyme, and cytochrome c is presented. These initial results offer encouragement for the further exploration of rf plasma polymer deposition as a novel approach for the development of on-probe affinity capture MALDI probes.

  17. Plasma lipid analysis by hydrophilic interaction liquid chromatography coupled with electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Sonomura, Kazuhiro; Kudoh, Shinobu; Sato, Taka-Aki; Matsuda, Fumihiko

    2015-06-01

    A novel method for the analysis of endogenous lipids and related compounds was developed employing hydrophilic interaction liquid chromatography with electrospray ionization tandem mass spectrometry. A hydrophilic interaction liquid chromatography with carbamoyl stationary phase achieved clear separation of phosphatidylcholine, lysophosphatidylcholine, sphingomyelin, ceramide, and mono-hexsosyl ceramide groups with good peak area repeatability (RSD% 0.99). The established method was applied to human plasma assays and a total of 117 endogenous lipids were successfully detected and reproducibly identified. In addition, we investigated the simultaneous detection of small polar metabolites such as amino and organic acids co-existing in the same biological samples processed in a single analytical run with lipids. Our results show that hydrophilic interaction liquid chromatography is a useful tool for human plasma lipidome analysis and offers more comprehensive metabolome coverage.

  18. [Analysis of Trace Inorganic Elements in Castor Oil by Inductively Coupled Plasma Mass Spectrometry].

    Science.gov (United States)

    Li, Tan-ping; Xie, Hua-lin; Nie, Xi-du

    2015-10-01

    A method for the determination of Na, Mg, Si, P, K, Ca, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Sr, Mo, Cd, Hg and Pb in castor oil after direct dilution with ethanol by inductively coupled plasma mass spectrometry (ICP-MS) was established. The sample was diluted by ethanol before ICP-MS determination. The condensation and deposition of high concentrations of carbon in mass cone interface and ion lens, which will decrease the sensitivity of element analysis, were avoided effectively by introducing O2 to plasma. The mass spectral interferences were eliminated by octopole reaction system (ORS). The matrix effects were calibrated to using Sc, Ge, Rh and Ir as internal standard elements. Au standard solution, which could form amalgam alloy with Hg, was dropped to eliminate the memory effect of Hg. The results show that the correlation coefficient for analyte is no less than 0.999 5, the detection limits is in the range of 0.06 - 20.1 ng x L(-1), the recovery is in the range of 990.4% - 110.2%, and the RSD is less than 4.8%. This method was very fast, simple and accurate to simultaneously analyze multi-elements in castor oil.

  19. Study of interaction of hot core plasma sources and micro-shock waves

    Science.gov (United States)

    Chelikani, Leela; Bagchi, Suman; Paturi, Prem Kiran

    2013-10-01

    Laser Induced Shockwaves (LISWs) have many applications from material processing to therapeutics. In almost all the processes and applications, understanding the conversion of laser energy to kinetic energy propagating as a shockwave (SW) is essential. We present the results on interaction of multiple plasma sources leading to SWs generated using Nd:YAG laser pulses (532 nm, 7 ns) (a) in atmospheric air and (b) from 1-D periodic structured surfaces (PSS) of 30 μm depth and 240 +/- 20 μm diameter having 25 and 64 lpi (lines per inch). Using time resolved shadowgraphy the novel aspects of (1) the presence of two distinct sources of ionization along the laser propagation direction modifying the nature of SWs around the focal plane and (2) the interaction of these two sources leading to the transition of hot core plasma in air analogous to that of a cavitation bubble in fluids are presented. Analogous phenomena of modification SW nature were observed from 1-D PSS. The effect of surface modulation on the SW and Contact Front dynamics was compared from that of a flat surface (FS). The initial studies in two different media indicate the possibility to control the SWs, either accelerate or decelerate by varying the plasma dynamics. Defence Research and Development Organization, India.

  20. Nanocomposite metal/plasma polymer films prepared by means of gas aggregation cluster source

    Energy Technology Data Exchange (ETDEWEB)

    Polonskyi, O.; Solar, P.; Kylian, O.; Drabik, M.; Artemenko, A.; Kousal, J.; Hanus, J.; Pesicka, J.; Matolinova, I. [Charles University in Prague, Faculty of Mathematics and Physics, V Holesovickach 2, 18000 Prague 8 (Czech Republic); Kolibalova, E. [Tescan, Libusina trida 21, 632 00 Brno (Czech Republic); Slavinska, D. [Charles University in Prague, Faculty of Mathematics and Physics, V Holesovickach 2, 18000 Prague 8 (Czech Republic); Biederman, H., E-mail: bieder@kmf.troja.mff.cuni.cz [Charles University in Prague, Faculty of Mathematics and Physics, V Holesovickach 2, 18000 Prague 8 (Czech Republic)

    2012-04-02

    Nanocomposite metal/plasma polymer films have been prepared by simultaneous plasma polymerization using a mixture of Ar/n-hexane and metal cluster beams. A simple compact cluster gas aggregation source is described and characterized with emphasis on the determination of the amount of charged clusters and their size distribution. It is shown that the fraction of neutral, positively and negatively charged nanoclusters leaving the gas aggregation source is largely influenced by used operational conditions. In addition, it is demonstrated that a large portion of Ag clusters is positively charged, especially when higher currents are used for their production. Deposition of nanocomposite Ag/C:H plasma polymer films is described in detail by means of cluster gas aggregation source. Basic characterization of the films is performed using transmission electron microscopy, ultraviolet-visible and Fourier-transform infrared spectroscopies. It is shown that the morphology, structure and optical properties of such prepared nanocomposites differ significantly from the ones fabricated by means of magnetron sputtering of Ag target in Ar/n-hexane mixture.

  1. Negative ion beam formation using thermal contact ionization type plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Fukuura, Yoshiyuki; Murakami, Kazutugu; Masuoka, Toshio; Katsumata, Itsuo [Osaka City Univ. (Japan). Faculty of Engineering

    1997-02-01

    The small ion sources utilizing thermal ionization have been already developed, and at present, in order to increase ion yield, that being developed to the cylindrical plasma prototype having the inner surface of a Re foil cylinder as the ionization surface, and stably functioning at 3,000 K has been developed, and by using this plasma source, the research on the formation of various ions has been carried out. At present, the research on the formation of Li negative ion beam is carried out. The separation of negative ions from electrons is performed with the locally limited magnetic field using a small iron core electromagnet placed behind the electrostatic accelerating lens system. So for, the formation of about 2 {mu}A at maximum of negative ions was confirmed. It was decided to identify the kinds of ions by time of flight (TOF) process, and the various improvements for this purpose were carried out. The experimental setup, the structure of the plasma source, the circuits for TOF measurement and so on are explained. The experimental results are reported. The problems are the possibility of the formation of alkali metals, the resolution of the time axis of the TOF system and so on. (K.I.)

  2. Penning plasma based simultaneous light emission source of visible and VUV lights

    Science.gov (United States)

    Vyas, G. L.; Prakash, R.; Pal, U. N.; Manchanda, R.; Halder, N.

    2016-06-01

    In this paper, a laboratory-based penning plasma discharge source is reported which has been developed in two anode configurations and is able to produce visible and VUV lights simultaneously. The developed source has simultaneous diagnostics facility using Langmuir probe and optical emission spectroscopy. The two anode configurations, namely, double ring and rectangular configurations, have been studied and compared for optimum use of the geometry for efficient light emissions and recording. The plasma is produced using helium gas and admixture of three noble gases including helium, neon, and argon. The source is capable to produce eight spectral lines for pure helium in the VUV range from 20 to 60 nm and total 24 spectral lines covering the wavelength range 20-106 nm for the admixture of gases. The large range of VUV lines is generated from gaseous admixture rather from the sputtered materials. The recorded spectrum shows that the plasma light radiations in both visible and VUV range are larger in double ring configuration than that of the rectangular configurations at the same discharge operating conditions. To clearly understand the difference, the imaging of the discharge using ICCD camera and particle-in-cell simulation using VORPAL have also been carried out. The effect of ion diffusion, metastable collision with the anode wall and the nonlinear effects are correlated to explain the results.

  3. Penning plasma based simultaneous light emission source of visible and VUV lights

    Energy Technology Data Exchange (ETDEWEB)

    Vyas, G. L., E-mail: glvyas27@gmail.com [Manipal University Jaipur (India); Prakash, R.; Pal, U. N. [CSIR-Central Electronics and Engineering Research Institute, Microwave Tubes Division (India); Manchanda, R. [Institute for Plasma Research (India); Halder, N. [Manipal University Jaipur (India)

    2016-06-15

    In this paper, a laboratory-based penning plasma discharge source is reported which has been developed in two anode configurations and is able to produce visible and VUV lights simultaneously. The developed source has simultaneous diagnostics facility using Langmuir probe and optical emission spectroscopy. The two anode configurations, namely, double ring and rectangular configurations, have been studied and compared for optimum use of the geometry for efficient light emissions and recording. The plasma is produced using helium gas and admixture of three noble gases including helium, neon, and argon. The source is capable to produce eight spectral lines for pure helium in the VUV range from 20 to 60 nm and total 24 spectral lines covering the wavelength range 20–106 nm for the admixture of gases. The large range of VUV lines is generated from gaseous admixture rather from the sputtered materials. The recorded spectrum shows that the plasma light radiations in both visible and VUV range are larger in double ring configuration than that of the rectangular configurations at the same discharge operating conditions. To clearly understand the difference, the imaging of the discharge using ICCD camera and particle-in-cell simulation using VORPAL have also been carried out. The effect of ion diffusion, metastable collision with the anode wall and the nonlinear effects are correlated to explain the results.

  4. Evaluation of the analytical capability of NIR femtosecond laser ablation-inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Hirata, Takafumi; Kon, Yoshiaki

    2008-03-01

    A laser ablation-inductively coupled plasma-mass spectrometric (LA-ICPMS) technique utilizing a titanium-sapphire (TiS) femtosecond laser (fs-laser) has been developed for elemental and isotopic analysis. The signal intensity profile, depth of the ablation pit and level of elemental fractionation were investigated in order to evaluate the analytical capability of the present fs-laser ablation-ICPMS technique. The signal intensity profile of (57)Fe, obtained from iron sulfide (FeS(2)), demonstrated that the resulting signal intensity of (57)Fe achieved by the fs-laser ablation was almost 4-times higher than that obtained by ArF excimer laser ablation under a similar energy fluence (5 J/cm(2)). In fs-laser ablation, there is no significant difference in a depth of the ablation pit between glass and zircon material, while in ArF laser ablation, the resulting crater depth on the zircon crystal was almost half the level than that obtained for glass material. Both the thermal-induced and particle size-related elemental fractionations, which have been thought to be main sources of analytical error in the LA-ICPMS analysis, were measured on a Harvard 91500 zircon crystal. The resulting fractionation indexes on the (206)Pb/(238)U (f(Pb/U)) and (238)U/(232)Th (f(U/Th)) ratios obtained by the present fs-laser ablation system were significantly smaller than those obtained by a conventional ArF excimer laser ablation system, demonstrative of smaller elemental fractionation. Using the present fs-laser ablation technique, the time profile of the signal intensity of (56)Fe and the isotopic ratios ((57)Fe/(54)Fe and (56)Fe/(54)Fe) have been measured on a natural pyrite (FeS(2)) sample. Repeatability in signal intensity of (56)Fe achieved by the fs-laser ablation system was significantly better than that obtained by ArF excimer laser ablation. Moreover, the resulting precision in (57)Fe/(54)Fe and (56)Fe/(54)Fe ratio measurements could be improved by the fs-laser ablation system

  5. Plasma kinetics, tissue distribution, and cerebrocortical sources of reverse triiodothyronine in the rat

    Energy Technology Data Exchange (ETDEWEB)

    Obregon, M.J.; Larsen, P.R.; Silva, J.E.

    1985-06-01

    Studies in vitro have shown that rT3 is a potent and competitive inhibitor of T4 5'-deiodination (5'D). Recent studies in vivo have shown that cerebrocortical (Cx) T4 5'D-type II (5'D-II) activity (propylthiouracil (PTU) insensitive pathway), is reduced by T4 and rT3, the latter being more potent than T3 in Cx 5'D-II suppression. Some other reports had described rT3 production in rat brain as a very active pathway of thyroid hormone metabolism. To examine the possibility that rT3 plays a physiological role in regulating Cx 5'D-II, we have explored rT3 plasma kinetics, plasma to tissue exchange, and uptake by tissues in the rat, as well as the metabolic routes of degradation and the sources of rT3 in cerebral cortex (Cx). Plasma and tissue levels were assessed with tracer (/sup 125/I)rT3. Two main compartments were defined by plasma disappearance curves in euthyroid rats (K/sub 1/ = -6.2 h-1 and K/sub 2/ = -0.75 h-1). In Cx of euthyroid rats, (/sup 125/I)rT3 peaked 10 min after iv injection, tissue to plasma ratio being 0.016 +/- 0.004 (SE). In thyroidectomized rats, plasma and tissue (/sup 125/I)rT3 concentrations were higher than in euthyroid rats, except for the Cx that did not change. PTU caused further increases in all the tissues studied, except for the Cx and the pituitaries of thyroidectomized rats. From the effect of blocking 5'D-I with PTU or reducing its activity by making the animals hypothyroid, we concluded that 5'D-I accounts for most of the rT3 clearance from plasma. In contrast, in Cx and pituitary the levels of rT3 seem largely affected by 5'D-II activity. Since the latter results suggest that plasma rT3 does not play a major role in determining rT3 levels in these tissues, we explored the sources of rT3 in Cx using (/sup 125/I)T4. The (/sup 125/I)rT3 (T4) to (/sup 125/I)T4 ratio remained constant at 0.03 from 1 up to 5 h after injection of (/sup 125/I)T4.

  6. Field-assisted paper spray mass spectrometry for the quantitative evaluation of imatinib levels in plasma.

    Science.gov (United States)

    D'Aronco, Sara; Calandra, Eleonora; Crotti, Sara; Toffoli, Giuseppe; Marangon, Elena; Posocco, Bianca; Traldi, Pietro; Agostini, Marco

    Drug levels in patients' bloodstreams vary among individuals and consequently therapeutic drug monitoring (TDM) is fundamental to controlling the effective therapeutic range. For TDM purposes, different analytical approaches have been used, mainly based on immunoassay, liquid chromatography- ultraviolet, liquid chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods. More recently a matrix-assisted laser desorption/ionisation method has been proposed for the determination of irinotecan levels in the plasma of subjects under therapy and this method has been cross- validated by comparison with data achieved by LC-MS/MS. However, to reach an effective point-of-care monitoring of plasma drug concentrations, a TDM platform technology for fast, accurate, low-cost assays is required. In this frame, recently the use of paper spray mass spectrometry, which is becoming a popular and widely employed MS method, has been proposed. In this paper we report the results obtained by the development of a paper spray-based method for quantitative analysis in plasma samples of imatinib, a new generation of anticancer drug. Preliminary experiments showed that poor sensitivity, reproducibility and linear response were obtained by the "classical" paper spray set-up. In order to achieve better results, it was thought of interest to operate in presence of a higher and more homogeneous electrical field. For this aim, a stainless steel needle connected with the high voltage power supply was mounted below the paper triangle. Furthermore, in order to obtain valid quantitative data, we analysed the role of the different equilibria participating to the phenomena occurring in paper spray experiments, depending either on instrumental parameters or on the chemical nature of analyte and solvents. A calibration curve was obtained by spiking plasma samples containing different amounts of imatinib (1) with known amounts of deuterated imatinib (1d3) as

  7. Plasma and Magnetic Field Characteristics of Solar Coronal Mass Ejections in Relation to Geomagnetic Storm Intensity and Variability

    CERN Document Server

    Liu, Ying D; Wang, Rui; Yang, Zhongwei; Zhu, Bei; Liu, Yi A; Luhmann, Janet G; Richardson, John D

    2015-01-01

    The largest geomagnetic storms of solar cycle 24 so far occurred on 2015 March 17 and June 22 with $D_{\\rm st}$ minima of $-223$ and $-195$ nT, respectively. Both of the geomagnetic storms show a multi-step development. We examine the plasma and magnetic field characteristics of the driving coronal mass ejections (CMEs) in connection with the development of the geomagnetic storms. A particular effort is to reconstruct the in situ structure using a Grad-Shafranov technique and compare the reconstruction results with solar observations, which gives a larger spatial perspective of the source conditions than one-dimensional in situ measurements. Key results are obtained concerning how the plasma and magnetic field characteristics of CMEs control the geomagnetic storm intensity and variability: (1) a sheath-ejecta-ejecta mechanism and a sheath-sheath-ejecta scenario are proposed for the multi-step development of the 2015 March 17 and June 22 geomagnetic storms, respectively; (2) two contrasting cases of how the CM...

  8. Simultaneous determination of irbesartan and hydrochlorothiazide in human plasma using HPLC coupled with tandem mass spectrometry: Application to bioequivalence studies.

    Science.gov (United States)

    Tutunji, Lara F; Tutunji, Maha F; Alzoubi, Mamoun I; Khabbas, Manal H; Arida, Adi I

    2010-03-11

    A sensitive, specific and selective liquid chromatography/tandem mass spectrometric method has been developed and validated for the simultaneous determination of irbesartan and hydrochlorothiazide in human plasma. Plasma samples were prepared using protein precipitation with acetonitrile, the two analytes and the internal standard losartan were separated on a reverse phase C(18) column (50mmx4mm, 3microm) using water with 2.5% formic acid, methanol and acetonitrile (40:45:15, v/v/v (%)) as a mobile phase (flow rate of 0.70mL/min). Irbesartan and hydrochlorothiazide were ionized using ESI source in negative ion mode, prior to detection by multiple reaction monitoring (MRM) mode while monitoring at the following transitions: m/z 296-->269 and m/z 296-->205 for hydrochlorothiazide, 427-->175 for irbesartan. Linearity was demonstrated over the concentration range 0.06-6.00microg/mL for irbesartan and 1.00-112.00ng/mL for hydrochlorothiazide. The developed and validated method was successfully applied to a bioequivalence study of irbesartan (300mg) with hydrochlorothiazide (12.5mg) tablet in healthy volunteers (N=36).

  9. Determination of L-ephedrine, pseudoephedrine, and caffeine in rat plasma by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Cooper, Stephen D; Fletcher, Brenda L; Silinski, Melanie A Rehder; Brown, Sherri S; Lodge, Jon W; Fernando, Reshan A; Collins, Bradley J

    2011-07-01

    A rapid and simple liquid chromatography tandem mass spectrometry method was developed and validated for the simultaneous determination of L-ephedrine, pseudoephedrine, and caffeine in male Fisher-344 rat plasma at nanogram-per-milliliter concentrations for use in support of toxicology studies. Only 25 μL of plasma is required, and extraction is performed using a simple, single-step protein precipitation. The method was validated over a range of 2.09 to 5460 ng/mL for L-ephedrine, 2.09 to 5050 ng/mL for pseudoephedrine and 2.03 to 5340 ng/mL for caffeine. A binary gradient elution at 0.3 mL/min was used with a Waters XBridge Phenyl (2.1 × 150 mm, 3.5 μm) column and a Waters XBridge Phenyl 2.1- × 10-mm guard column at ambient temperature. The mobile phase consisted of 10 mM ammonium acetate in water (pH 5.0) and methanol. Caffeine trimethyl-(13)C(3) was used as the internal standard. The method was evaluated for linearity, recovery, precision, accuracy, and stability, and it was successfully applied in toxicokinetic studies of ephedrine, administered alone, in combination with caffeine, and in the herbal source Ma Huang.

  10. Investigation of a measure of robustness in inductively coupled plasma mass spectrometry

    Science.gov (United States)

    Makonnen, Yoseif; Beauchemin, Diane

    2015-01-01

    In industrial/commercial settings where operators often have minimal expertise in inductively coupled plasma (ICP) mass spectrometry (MS), there is a prevalent need for a response factor indicating robust plasma conditions, which is analogous to the Mg II/Mg I ratio in ICP optical emission spectrometry (OES), whereby a Mg II/Mg I ratio of 10 constitutes robust conditions. While minimizing the oxide ratio usually corresponds to robust conditions, there is no specific target value that is widely accepted as indicating robust conditions. Furthermore, tuning for low oxide ratios does not necessarily guarantee minimal matrix effects, as they really address polyatomic interferences. From experiments, conducted in parallel for both MS and OES, there were some element pairs of similar mass and very different ionization potential that were exploited for such a purpose, the rationale being that, if these elements were ionized to the same extent, then that could be indicative of a robust plasma. The Be II/Li I intensity ratio was directly related to the Mg II/Mg I ratio in OES. Moreover, the 9Be+/7Li+ ratio was inversely related to the CeO+/Ce+ and LaO+/La+ oxide ratios in MS. The effects of different matrices (i.e. 0.01-0.1 M Na) were also investigated and compared to a conventional argon plasma optimized for maximum sensitivity. The suppression effect of these matrices was significantly reduced, if not eliminated in the case of 0.01 M Na, when the 9Be+/7Li+ ratio was around 0.30 on the Varian 820 MS instrument. Moreover, a very similar ratio (0.28) increased robustness to the same extent on a completely different ICP-MS instrument (PerkinElmer NEXION). Much greater robustness was achieved using a mixed-gas plasma with nitrogen in the outer gas and either nitrogen or hydrogen as a sheathing gas, as the 9Be+/7Li+ ratio was then around 1.70. To the best of our knowledge, this is the first report on using a simple analyte intensity ratio, 9Be+/7Li+, to gauge plasma robustness.

  11. CERN LINAC4 H- Source and SPL plasma generator RF systems, RF power coupling and impedance measurements

    CERN Document Server

    Paoluzzi, M; Marques-Balula, J; Nisbet, D

    2010-01-01

    In the LINAC4 H- source and the SPL plasma generator at CERN, the plasma is heated by a 100 kW, 2 MHz RF system. Matching of the load impedance to the final amplifier is achieved with a resonant network. The system implements a servo loop for power stabilization and frequency hopping to cope with the detuning effects induced by the plasma. This paper provides a detailed description of the system, including the pulse rate increase to 50 Hz for use in the SPL plasma generator. The performances, measurements of RF power coupling, contribution of the plasma to the impedance as well as first operation are reported.

  12. Mass Transfer Limited Enhanced Bioremediation at Dnapl Source Zones: a Numerical Study

    Science.gov (United States)

    Kokkinaki, A.; Sleep, B. E.

    2011-12-01

    The success of enhanced bioremediation of dense non-aqueous phase liquids (DNAPLs) relies on accelerating contaminant mass transfer from the organic to the aqueous phase, thus enhancing the depletion of DNAPL source zones compared to natural dissolution. This is achieved by promoting biological activity that reduces the contaminant's aqueous phase concentration. Although laboratory studies have demonstrated that high reaction rates are attainable by specialized microbial cultures in DNAPL source zones, field applications of the technology report lower reaction rates and prolonged remediation times. One possible explanation for this phenomenon is that the reaction rates are limited by the rate at which the contaminant partitions from the DNAPL to the aqueous phase. In such cases, slow mass transfer to the aqueous phase reduces the bioavailability of the contaminant and consequently decreases the potential source zone depletion enhancement. In this work, the effect of rate limited mass transfer on bio-enhanced dissolution of DNAPL chlorinated ethenes is investigated through a numerical study. A multi-phase, multi-component groundwater transport model is employed to simulate DNAPL mass depletion for a range of source zone scenarios. Rate limited mass transfer is modeled by a linear driving force model, employing a thermodynamic approach for the calculation of the DNAPL - water interfacial area. Metabolic reductive dechlorination is modeled by Monod kinetics, considering microbial growth and self-inhibition. The model was utilized to identify conditions in which mass transfer, rather than reaction, is the limiting process, as indicated by the bioavailability number. In such cases, reaction is slower than expected, and further increase in the reaction rate does not enhance mass depletion. Mass transfer rate limitations were shown to affect both dechlorination and microbial growth kinetics. The complex dynamics between mass transfer, DNAPL transport and distribution, and

  13. Laser-driven electron beamlines generated by coupling laser-plasma sources with conventional transport systems

    Energy Technology Data Exchange (ETDEWEB)

    Antici, P. [Istituto Nazionale di Fisica Nucleare (INFN), Laboratori Nazionali di Frascati, Via E. Fermi, 40, 00044 Frascati (Italy); SAPIENZA, University of Rome, Dip. SBAI, Via A. Scarpa 14, 00161 Rome (Italy); INFN - Sezione di Roma, c/o Dipartimento di Fisica - SAPIENZA, University of Rome, P.le Aldo Moro, 2 - 00185 Rome (Italy); Bacci, A.; Chiadroni, E.; Ferrario, M.; Rossi, A. R. [Istituto Nazionale di Fisica Nucleare (INFN), Laboratori Nazionali di Frascati, Via E. Fermi, 40, 00044 Frascati (Italy); Benedetti, C. [University of Bologna and INFN - Bologna (Italy); Lancia, L.; Migliorati, M.; Mostacci, A.; Palumbo, L. [SAPIENZA, University of Rome, Dip. SBAI, Via A. Scarpa 14, 00161 Rome (Italy); INFN - Sezione di Roma, c/o Dipartimento di Fisica - SAPIENZA, University of Rome, P.le Aldo Moro, 2 - 00185 Rome (Italy); Serafini, L. [INFN-Milan and Department of Physics, University of Milan, Via Celoria 16, 20133 Milan (Italy)

    2012-08-15

    Laser-driven electron beamlines are receiving increasing interest from the particle accelerator community. In particular, the high initial energy, low emittance, and high beam current of the plasma based electron source potentially allow generating much more compact and bright particle accelerators than what conventional accelerator technology can achieve. Using laser-generated particles as injectors for generating beamlines could significantly reduce the size and cost of accelerator facilities. Unfortunately, several features of laser-based particle beams need still to be improved before considering them for particle beamlines and thus enable the use of plasma-driven accelerators for the multiple applications of traditional accelerators. Besides working on the plasma source itself, a promising approach to shape the laser-generated beams is coupling them with conventional accelerator elements in order to benefit from both a versatile electron source and a controllable beam. In this paper, we perform start-to-end simulations to generate laser-driven beamlines using conventional accelerator codes and methodologies. Starting with laser-generated electrons that can be obtained with established multi-hundred TW laser systems, we compare different options to capture and transport the beams. This is performed with the aim of providing beamlines suitable for potential applications, such as free electron lasers. In our approach, we have analyzed which parameters are critical at the source and from there evaluated different ways to overcome these issues using conventional accelerator elements and methods. We show that electron driven beamlines are potentially feasible, but exploiting their full potential requires extensive improvement of the source parameters or innovative technological devices for their transport and capture.

  14. Laser-driven electron beamlines generated by coupling laser-plasma sources with conventional transport systems

    Science.gov (United States)

    Antici, P.; Bacci, A.; Benedetti, C.; Chiadroni, E.; Ferrario, M.; Rossi, A. R.; Lancia, L.; Migliorati, M.; Mostacci, A.; Palumbo, L.; Serafini, L.

    2012-08-01

    Laser-driven electron beamlines are receiving increasing interest from the particle accelerator community. In particular, the high initial energy, low emittance, and high beam current of the plasma based electron source potentially allow generating much more compact and bright particle accelerators than what conventional accelerator technology can achieve. Using laser-generated particles as injectors for generating beamlines could significantly reduce the size and cost of accelerator facilities. Unfortunately, several features of laser-based particle beams need still to be improved before considering them for particle beamlines and thus enable the use of plasma-driven accelerators for the multiple applications of traditional accelerators. Besides working on the plasma source itself, a promising approach to shape the laser-generated beams is coupling them with conventional accelerator elements in order to benefit from both a versatile electron source and a controllable beam. In this paper, we perform start-to-end simulations to generate laser-driven beamlines using conventional accelerator codes and methodologies. Starting with laser-generated electrons that can be obtained with established multi-hundred TW laser systems, we compare different options to capture and transport the beams. This is performed with the aim of providing beamlines suitable for potential applications, such as free electron lasers. In our approach, we have analyzed which parameters are critical at the source and from there evaluated different ways to overcome these issues using conventional accelerator elements and methods. We show that electron driven beamlines are potentially feasible, but exploiting their full potential requires extensive improvement of the source parameters or innovative technological devices for their transport and capture.

  15. High Performance Liquid Chromatography Tandem Mass Spectrometry Assay for the Determination of Cobinamide in Pig Plasma

    Science.gov (United States)

    McCracken, Brent A.; Brittain, Matthew K.

    2015-01-01

    Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been widely utilized for the analysis of compounds in biological matrices due to its selectivity and sensitivity. This study describes the application of an LC-MS/MS-based approach toward the analysis of cobinamide in Yorkshire pig plasma. The selectivity, accuracy, precision, recovery, linearity, range, carryover, sensitivity, matrix effect, interference, stability, reproducibility, and ruggedness of the method were investigated in pig plasma. The accuracy and precision of the method was determined to be within 10% over three different days over a range of concentrations (25–10,000 ng/mL) that spanned more than two orders of magnitude. The lower limit of quantitation (LLOQ) for dicyanocobinamide was determined to be 25 ng/mL in pig plasma. Carryover was acceptable, as the area response of the carryover blanks were ≤15% of the area response of the nearest LLOQ standard for the analyte, while it was nonexistent for the internal standard. Specificity was ensured using six different lots of pig plasma. While the matrix effects of dicyanocobinamide in plasma were enhanced, ginsenoside Rb1 experienced signal suppression under the described conditions. The absolute recovery results for both compounds were consistent, precise, and reproducibly lower than expected at ~60% for dicyanocobinamide and ~22% for ginsenoside Rb1, confirming that a matrix standard curve was required for accurate quantitation. Cobinamide was shown to be very stable in matrix at various storage conditions including room temperature, refrigerated, and frozen at time intervals of 20 hours, 4 days, and 60 days respectively. This method was demonstrated to be sensitive, reproducible, stable, and rugged, and it should be applicable to the analysis of cobinamide in other biological matrices and species. PMID:26540437

  16. Probing silicon substitution in molecular sieves by plasma desorption mass spectrometry

    Science.gov (United States)

    Van Stipdonk, M. J.; von Heimburg, S. L.; Schweikert, E. A.

    1998-10-01

    Plasma desorption was used to produce secondary ion mass spectra from samples of unsubstituted and substituted aluminum phosphate materials. The yield of fingerprint ions representative of silicon oxide solids indicates that the incorporation of silicon into the material during synthesis and following calcination occurs via the formation of silicon-rich islands. Complementary X-ray photoelectron data provide supporting evidence that the surface of the substituted aluminum phosphate material becomes silicon rich and phosphorus depleted. No changes in the unsubstituted and substituted material with respect to composition and phase were detected using powder X-ray diffraction.

  17. A Proposal for a Novel H- Ion Source Based on Electron Cyclotron Resonance Plasma Heating and Surface Ionization

    Science.gov (United States)

    Tarvainen, O.; Kurennoy, S.

    2009-03-01

    A design for a novel H- ion source based on electron cyclotron resonance plasma heating and surface ionization is presented. The plasma chamber of the source is an rf-cavity designed for TE111 eigenmode at 2.45 GHz. The desired mode is excited with a loop antenna. The ionization process takes place on a cesiated surface of a biased converter electrode. The H- ion beam is further "self-extracted" through the plasma region. The magnetic field of the source is optimized for plasma generation by electron cyclotron resonance heating, and beam extraction. The design features of the source are discussed in detail and the attainable H- ion current, beam emittance and duty factor of the novel source are estimated.

  18. Composition Dependent Evolution in Mass Flux from Binary Trichloroethene/Tetrachloroethene-DNAPL Source Zones

    Science.gov (United States)

    Walker, D. I.; Cápiro, N. L.; Granbery, E. K.; Pennell, K. D.

    2010-12-01

    In order to accurately predict the efficacy of subsurface remediation for sites contaminated with multicomponent dense non-aqueous phase liquids (DNAPLs), it is necessary to link changes in aqueous phase contaminant discharge with source composition and distribution. Dissolution from a binary 1:1 (molar) mixture of trichloroethene- (TCE) and tetrachloroethene- (PCE) DNAPL was measured in three separate 2-dimensional aquifer cells (100 x 48 x 1.4 cm) that were packed with different background media (1:1 mixture 20:30 and 40:50 mesh; 20:30 mesh and 40:50 mesh Accusand) and low permeability zones. Initial DNAPL source zone architectures were varied to yield ganglia to pool (GTP) ratios of 0.44, 1.56, and 1.72. Down-gradient plume evolution and DNAPL spatial distribution were measured every 5 pore volumes (PV) from side port samples and a light transmission system that allowed non-invasive measurement of volumetric DNAPL saturation and source descriptive metrics at a resolution of 0.03 to 0.08 mm2. Flux-averaged PCE and TCE effluent concentrations were measured every 0.7 PVs from a fully screened effluent chamber. To accelerate changes in source zone architecture and overall mass removal, two surfactant floods (4% w/w Tween 80) were completed after mass discharge from the source zone reached a steady state. Mass flux reductions for a given amount of DNAPL mass removed were found to correspond strongly to the molar composition of DNAPL in the source zone and the initial DNAPL saturation distribution metric (e.g., GTP). Percent reductions in mass flux from the aquifer cells with ganglia dominated architectures were 98 and 72% for TCE and PCE respectively, with a final overall NAPL source zone molar ratio of 0.49:0.51 TCE: PCE ; and 97 and 79% for TCE and PCE with molar ratios of 0.19:0.81 TCE:PCE. Reductions in mass flux from the pool dominated source zone were 90 and 53% for TCE and PCE with a final overall DNAPL source zone mole fraction of 0.26:0.74 TCE:PCE. These

  19. The effect of boron supplementation on lean body mass, plasma testosterone levels, and strength in male bodybuilders

    Science.gov (United States)

    Ferrando, A. A.; Green, N. R.

    1993-01-01

    The effect of boron supplementation was investigated in 19 male bodybuilders ages 20-27 years. Ten were given a 2.5-mg boron supplement while 9 were given a placebo every day for 7 weeks. Plasma total and free testosterone, plasma boron, lean body mass, and strength measurements were determined on Days 1 and 49 of the study. Plasma boron values were significantly (p bodybuilding can increase total testosterone, lean body mass, and strength in lesser trained bodybuilders, and that boron supplementation had no effect on these measures.

  20. Development and evaluation of magnesium oxide-based ceramics for chamber parts in mass-production plasma etching equipment

    Science.gov (United States)

    Kasashima, Yuji; Tsutsumi, Kota; Mitomi, Shinzo; Uesugi, Fumihiko

    2017-06-01

    In mass-production plasma etching equipment, the corrosion of ceramic chamber parts reduces the production yield of LSI and overall equipment effectiveness (OEE) owing to contamination, short useful life, and particle generation. Novel ceramics that can improve the production yield and OEE are highly required. We develop magnesium oxide (MgO)-based ceramics and evaluate them under mass-production plasma etching conditions. The results of this study indicate that the developed MgO-based ceramics with high mechanical properties and low electric resistivity have a higher resistance to corrosion in plasma etching using CF4 gas than Si and conventional ceramic materials such as aluminum oxide and yttrium oxide.

  1. Rapid and simultaneous quantification of levetiracetam and its carboxylic metabolite in human plasma by liquid chromatography tandem mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Li-Ling Yeap

    Full Text Available A simple liquid chromatography tandem mass spectrometry method was developed and validated according to the guidelines of the US Food and Drug Administration and the European Medicines Agency for a simultaneous quantification of levetiracetam (LEV and its metabolite, UCB L057 in the plasma of patients. A 0.050 mL plasma sample was prepared by a simple and direct protein precipitation with 0.450 mL acetonitrile (ACN containing 1 µg/mL of internal standard (IS, diphenhydramine, then vortex mixed and centrifuged. A 0.100 mL of the clear supernatant was diluted with 0.400 mL water and well mixed. A 0.010 mL of the resultant solution was injected into an Agilent Zorbax SB-C18 (2.1 mm×100 mm, 3.5 µm column with an isocratic elution at 0.5 mL/min using a mixture of 0.1% formic acid in water and ACN (40:60 v/v. Detection was performed using an AB Sciex API 3000 triple quadrupole mass spectrometer, equipped with a Turbo Ion Spray source, operating in a positive mode: LEV at transition 171.1>154.1, UCB L057 at 172.5>126.1, and IS at 256.3>167.3; with an assay run time of 2 minutes. The lower limit of quantification (LLOQ for both LEV and UCB L057 was validated at 0.5 µg/mL, while their lower limit of detection (LOD was 0.25 µg/mL. The calibration curves were linear between 0.5 and 100 µg/mL for both analytes. The inaccuracy and imprecision of both intra-assay and inter-assay were less than 10%. Matrix effects were consistent between sources of plasma and the recoveries of all compounds were between 100% and 110%. Stability was established under various storage and processing conditions. The carryovers from both LEV and UCB L057 were less than 6% of the LLOQ and 0.13% of the IS. This assay method has been successfully applied to a population pharmacokinetic study of LEV in patients with epilepsy.

  2. Rapid and simultaneous quantification of levetiracetam and its carboxylic metabolite in human plasma by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Yeap, Li-Ling; Lo, Yoke-Lin

    2014-01-01

    A simple liquid chromatography tandem mass spectrometry method was developed and validated according to the guidelines of the US Food and Drug Administration and the European Medicines Agency for a simultaneous quantification of levetiracetam (LEV) and its metabolite, UCB L057 in the plasma of patients. A 0.050 mL plasma sample was prepared by a simple and direct protein precipitation with 0.450 mL acetonitrile (ACN) containing 1 µg/mL of internal standard (IS, diphenhydramine), then vortex mixed and centrifuged. A 0.100 mL of the clear supernatant was diluted with 0.400 mL water and well mixed. A 0.010 mL of the resultant solution was injected into an Agilent Zorbax SB-C18 (2.1 mm×100 mm, 3.5 µm) column with an isocratic elution at 0.5 mL/min using a mixture of 0.1% formic acid in water and ACN (40:60 v/v). Detection was performed using an AB Sciex API 3000 triple quadrupole mass spectrometer, equipped with a Turbo Ion Spray source, operating in a positive mode: LEV at transition 171.1>154.1, UCB L057 at 172.5>126.1, and IS at 256.3>167.3; with an assay run time of 2 minutes. The lower limit of quantification (LLOQ) for both LEV and UCB L057 was validated at 0.5 µg/mL, while their lower limit of detection (LOD) was 0.25 µg/mL. The calibration curves were linear between 0.5 and 100 µg/mL for both analytes. The inaccuracy and imprecision of both intra-assay and inter-assay were less than 10%. Matrix effects were consistent between sources of plasma and the recoveries of all compounds were between 100% and 110%. Stability was established under various storage and processing conditions. The carryovers from both LEV and UCB L057 were less than 6% of the LLOQ and 0.13% of the IS. This assay method has been successfully applied to a population pharmacokinetic study of LEV in patients with epilepsy.

  3. Stellar-mass black holes and ultraluminous x-ray sources.

    Science.gov (United States)

    Fender, Rob; Belloni, Tomaso

    2012-08-03

    We review the likely population, observational properties, and broad implications of stellar-mass black holes and ultraluminous x-ray sources. We focus on the clear empirical rules connecting accretion and outflow that have been established for stellar-mass black holes in binary systems in the past decade and a half. These patterns of behavior are probably the keys that will allow us to understand black hole feedback on the largest scales over cosmological time scales.

  4. Liquid chromatography/electrospray ionization mass spectrometric characterization of Harpagophytum in equine urine and plasma.

    Science.gov (United States)

    Colas, Cyril; Garcia, Patrice; Popot, Marie-Agnès; Bonnaire, Yves; Bouchonnet, Stéphane

    2006-01-01

    A method has been developed for the analysis and characterization in equine urine and plasma of iridoid glycosides: harpagide, harpagoside and 8-para-coumaroyl harpagide, which are the main active principles of Harpagophytum, a plant with antiinflammatory properties. The method involves liquid chromatography coupled with positive electrospray ionization mass spectrometry. The addition of sodium or lithium chloride instead of formic acid in the eluting solvent has been studied in order to enhance the signal and to modify the ion's internal energy. Fragmentation pathways and associated patterns are proposed for each analyte. A comparison of three types of mass spectrometer: a 3D ion trap, a triple quadrupole and a linear ion trap, has been conducted. The 3D ion trap was selected for drug screening analysis whereas the linear ion trap was retained for identification and quantitation analysis.

  5. Role of the electron mass in damping chiral plasma instability in Supernovae and neutron stars

    Science.gov (United States)

    Grabowska, Dorota; Kaplan, David B.; Reddy, Sanjay

    2015-04-01

    We show that the nonzero electron mass plays a critical role in determining the magnetic properties of neutron stars by suppressing the generation of the chiral charge density needed to trigger a strong chiral plasma instability during the core collapse of supernovae. This instability has been proposed as a plausible mechanism for generating extremely large helical magnetic fields in neutron stars at their birth; the mechanism relies on the generation of a large nonequilibrium chiral charge density via electron capture reactions that selectively deplete left-handed electrons during core collapse and the early evolution of the protoneutron star. Our calculation shows that the electron chirality violation rate induced by Rutherford scattering, despite being suppressed by the smallness of the electron mass relative to the electron chemical potential, is still fast compared to the weak interaction electron capture rate. The resulting asymmetry between right- and left-handed electron densities is therefore unlikely to attain an astrophysically relevant magnitude.

  6. A Movable Mass Spectroscopy Sampling Apparatus for Measuring Spatial Distribution of Neutral Radicals in Silane Plasma

    Institute of Scientific and Technical Information of China (English)

    WANG Zhao-Kui; LIN Kui-Xun; LIN Xuan-Ying; QIU Gui-Ming; ZHU Zu-Song

    2005-01-01

    @@ A movable mass spectroscopy gas sampling apparatus has been established and a straight-line fit ofsilane depletion fraction f is proposed.The spatial density distributions of SiHn (n = 0-3) radicals in silane radio frequency glow discharge have been measured by a mass spectrometer.The experimental results demonstrate that the densities of the neutral radicals have the peak value near the middle position of electrodes, and the densities of SiH2 and SiHs are higher than those of Si and SiH in silane plasma.This reveals that SiH2 and SiH3 may be the primary precursors in forming the a-Si:H film.

  7. Determination of trace multi-elements in coal fly ash by inductively coupled plasma mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    XIE Hua-lin; TANG You-gen; LI Yu-jie; LI Li-bo

    2007-01-01

    The contents of Cr,Cu, Ni, As, Cd and Pb in coal fly ash were determined by a high resolution inductively coupled plasma mass spectrometry method.The sample digestions were performed in closed microwave vessels with HN03, HClO4 and HF.The optimum conditions for the determination were obtained.The applicability of the proposed method was validated by the analysis of coal fly ash reference material (NIST SRM 1633a). The results show that most of the spectral interferences can be avoided by measuring in the high resolution mode(maximum mass resolution R=9 000).The detection limit is from 0.05 to 0.21μg/g,and the precision is fine with relative standard deviation less than 4.3%.

  8. Experimental investigation of laser-produced-plasma EUV source based on liquid target

    Institute of Scientific and Technical Information of China (English)

    QI Li-hong; NI Qi-liang; CHEN Bo

    2005-01-01

    A laser-produced plasma(LPP) source was built using liquid as target and a Nd:YAG laser as the irradiation laser, and the LPP source's radiation with ethanol and acetone target respectively was measured by an AXUV100 silicon photodiode combined with a McPHERSON model 247 grazing incidence monochromator of the resolution Δλ≤0.075 nm and the wavelength scanning interval 0.5 nm. Both ethanol and acetone target LPP source had EUV emission at 11~20 nm wavelength. The comparison between the spectra of the two kinds of target materials shows that all the two kinds of target source's spectra are the result of oxygen ions' transitions under current source's parameters, but the spectrum intensity from different target sources is different. The spectra intensity from the ethanol target is higher than that from the acetone target. In addition, the target liquid is forced into the vacuum chamber by the background pressure supported by the connected external high pressure gas, and the influence of the background pressure on the source's intensity is investigated.

  9. Chief sources of brachiopod recovery from the end Ordovician mass extinction with special references to progenitors

    Institute of Scientific and Technical Information of China (English)

    戎嘉余; 詹仁斌

    1999-01-01

    Survivor, Lazarus and progenitor taxa are sources of biotic recovery following mass extinction. Investigations of the benthic brachiopods through the latest Ordovician mass extinction shows that progenitors developed many evolutionary novelties and successful surviving mechanisms. They are superior to survivors and Lazarus taxa in their ability to adapt to environmental changes. They are the primary source of macroevolution and the ancestors of a number of new taxa. Three kinds of progenitors are recognized based on the Ordovician-Silurian brachiopods from South China: survivor-progenitors, crisis-progenitors and Lazarus-progenitors; the last has the strongest ability to resist adverse environments, and is the most diverse and abundant.

  10. Rapid and Sensitive Liquid Chromatography-Tandem Mass Spectrometry for Quantification of Glycyrrhctic Acid in Human Plasma

    Institute of Scientific and Technical Information of China (English)

    TIAN Li; GAO Xiao-li; CHEN Xiao-yan; ZHONG Da-fang; ZHANG Yi-fan; DAI Xiao-jian

    2011-01-01

    A simple, rapid and sensitive liquid chromatography-tandem mass spectrometry(LC-MS/MS) for the determination of glycyrrhetic acid in human plasma with ginsenoside Rh2 as internal standard was developed and validated. The plasma samples were prepared via liquid-liquid extraction with ethyl acetate. Chromatographic separation was accomplished on a Venusil MP-C1s(50 mm×2.1 mm, 5 μm i.d.) column at 25 ℃. The mobile phase consisted of acetonitrile/5 mmol·L-1 ammonium acetate(10:90, volume ratio) at a flow rate of 0.4 mL/min. Negative electrospray ionization was utilized as the ionization source. Glycyrrhetic acid and internal standard were determined via the mutiple reaction monitoring of precursor→production ion transitions at m/z 469→425, 409 and m/z 621→ 161,respectively. Each sample was chromatographed within 2.5 min. The lower limit of quantification was 0.50 ng/mL for 200 μL of plasma sample and the linear range was from 0.50 ng/mL to 800 ng/mL. The intra- and inter-day precisions were less than 8.76% in terms of relative standard deviation(RSD), and the accuracy was within a range of -3.25% -1.32% in terms of relative error(RE). The method was successfully applied to the pharmacokinetic studies of glycyrrhetic acid in healthy male Chinese volunteers after a single oral administration of 75 mg of glycyrrhizin.

  11. Fast plasma discharge capillary design as a high power throughput soft x-ray emission source.

    Science.gov (United States)

    Wyndham, E S; Favre, M; Valdivia, M P; Valenzuela, J C; Chuaqui, H; Bhuyan, H

    2010-09-01

    We present the experimental details and results from a low energy but high repetition rate compact plasma capillary source for extreme ultraviolet and soft x-ray research and applications. Two lengths of capillary are mounted in two versions of a closely related design. The discharge operates in 1.6 and 3.2 mm inner diameter alumina capillaries of lengths 21 and 36 mm. The use of water both as dielectric and as coolant simplifies the compact low inductance design with nanosecond discharge periods. The stored electrical energy of the discharge is approximately 0.5 J and is provided by directly charging the capacitor plates from an inexpensive insulated-gate bipolar transistor in 1 μs or less. We present characteristic argon spectra from plasma between 30 and 300 Å as well as temporally resolved x-ray energy fluence in discrete bands on axis. The spectra also allow the level of ablated wall material to be gauged and associated with useful capillary lifetime according to the chosen configuration and energy storage. The connection between the electron beams associated with the transient hollow cathode mechanism, soft x-ray output, capillary geometry, and capillary lifetime is reported. The role of these e-beams and the plasma as measured on-axis is discussed. The relation of the electron temperature and the ionization stages observed is discussed in the context of some model results of ionization in a non-Maxwellian plasma.

  12. Numerical simulation of the RF plasma discharge in the Linac4 H- ion source

    Science.gov (United States)

    Mattei, S.; Nishida, K.; Onai, M.; Lettry, J.; Tran, M. Q.; Hatayama, A.

    2017-08-01

    This paper presents a Particle-In-Cell Monte Carlo Collision simulation of the Radio-Frequency (RF) plasma heating in the Linac4 H- ion source at CERN. The model self-consistently takes into account the electromagnetic field generated by the RF coil, the external static magnetic fields and the resulting plasma response, including a kinetic description of the charged species (e-, H+, H2-, H3+, H-), as well as the atomic and molecular (vibrationally resolved) populations. The simulation is performed for the nominal operational condition of 40 kW RF power and 3 Pa H2 pressure. Results show that the plasma spatial distribution is non-uniform in the plasma chamber, with a density peak of ne = 5 . 1019 m-3 in the RF coil region. In the filter field region the electron density drops by two orders of magnitude, with a substantial reduction of the electron energy as well. This results in a ratio e/H- ≈ 1 in the extraction region. The vibrational population is characterized by a two temperature distribution, with the high vibrational states showing a factor 2 higher termperature. A very good agreement is found between the simulation results and optical emission spectroscopy measurement performed on a dedicated test stand at CERN.

  13. The Project PLASMONX for Plasma Acceleration Experiments and a Thomson X-Ray Source at SPARC

    CERN Document Server

    Serafini, Luca; Alessandria, Franco; Bacci, Alberto; Baldeschi, Walter; Barbini, Alessandro; Bellaveglia, Marco; Bertolucci, Sergio; Biagini, Maria; Boni, Roberto; Bonifacio, Rodolfo; Boscolo, Ilario; Boscolo, Manuela; Bottigli, Ubaldo; Broggi, Francesco; Castellano, Michele; Cecchetti, Carlo A; Cialdi, Simone; Clozza, Alberto; De Martinis, Carlo; Di Pirro, Giampiero; Drago, Alessandro; Esposito, Adolfo; Ferrario, Massimo; Ficcadenti, L; Filippetto, Daniele; Fusco, Valeria; Galimberti, Marco; Gallo, Alessandro; Gatti, Giancarlo; Ghigo, Andrea; Giove, Dario; Giulietti, Antonio; Giulietti, Danilo; Gizzi, Leonida A; Golosio, Bruno; Guiducci, Susanna; Incurvati, Maurizio; Köster, Petra; Labate, Luca; Ligi, Carlo; Marcellini, Fabio; Maroli, Cesare; Mauri, Marco; Migliorati, Mauro; Mostacci, Andrea; Oliva, Pier N; Palumbo, Luigi; Pellegrino, Luigi; Petrillo, Vittoria; Piovella, Nicola; Poggiu, Angela; Pozzoli, Roberto; Preger, Miro; Ricci, Ruggero; Rome, Massimiliano; Rossi, Antonella; Sanelli, Claudio; Serio, Mario; Sgamma, Francesco; Spataro, Bruno; Stecchi, Alessandro; Stella, Angelo; Stumbo, Simone; Tazzioli, Franco; Tommasini, Paolo; Vaccarezza, Cristina; Vescovi, Mario; Vicario, Carlo

    2005-01-01

    We present the status of the activity on the project PLASMONX, which foresees the installation of a multi-TW Ti:Sa laser system at the CNR-ILIL laboratory to conduct plasma acceleration experiments and the construction of an additional beam line at SPARC to develop a Thomson X-ray source at INFN-LNF. After pursuing self-injection experiments at ILIL, when the electron beam at SPARC will be available the SPARC laser system will be upgraded to TW power level in order to conduct either external injection plasma acceleration experiments and ultra-bright X-ray pulse generation with the Thomson source. Results of numerical simulations modeling the interaction of the SPARC electron beam and the counter-propagating laser beam are presented with detailed discussion of the monochromatic X-ray beam spectra generated by Compton backscattering: X-ray energies are tunable in the range 20 to 1000 keV, with pulse duration from 30 fs to 20 ps. Preliminary simulations of plasma acceleration with self-injection are illustrated,...

  14. AmBe Radiological Source Replacement Using Dense Plasma Focus Z-Pinch

    Science.gov (United States)

    Shaw, Brian; Povilus, Alexander; Chapman, Steven; Podpaly, Yuri; Cooper, Christopher; Higginson, Drew; Link, Anthony; Schmidt, Andrea

    2016-10-01

    A dense plasma focus (DPF) is a compact plasma gun that produces high energy ion beams up to several MeV through strong potential gradients formed from m=0 plasma instabilities. These ion beams can be used to replace radiological sources for a variety of applications. Americium-beryllium (AmBe) neutron sources are commonly used for oil well logging. An optimized DPF produces high energy helium ion beams of 2+ MeV which can interact with a beryllium target to produce neutrons. The alpha-Be interaction produces a neutron energy spectrum similar to the neutrons produced by the AmBe reaction. To demonstrate this concept experimentally a 2 kJ DPF is used to produce a beam of alpha particles which interacts with a beryllium target. We report on the improvements made to the DPF platform using He gas and the observation of 3.0 ×104 peak neutrons generated per shot. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  15. Diamondlike carbon deposition on plastic films by plasma source ion implantation

    CERN Document Server

    Tanaka, T; Shinohara, M; Takagi, T

    2002-01-01

    Application of pulsed high negative voltage (approx 10 mu s pulse width, 300-900 pulses per second) to a substrate is found to induce discharge, thereby increasing ion current with an inductively coupled plasma source. This plasma source ion beam implantation (PSII) technique is investigated for the pretreatment and deposition of diamond-like carbon (DLC) thin layer on polyethylene terepthalate (PET) film. Pretreatment of PET with N sub 2 and Ar plasma is expected to provide added barrier effects when coupled with DLC deposition, with possible application to fabrication of PET beverage bottles. PSII treatment using N sub 2 and Ar in separate stages is found to change the color of the PET film, effectively increasing near-ultraviolet absorption. The effects of this pretreatment on the chemical bonding of C, H, and O are examined by x-ray photoelectron spectroscopy (XPS). DLC thin film was successfully deposited on the PET film. The surface of the DLC thin layer is observed to be smooth by scanning electron mic...

  16. Matching a (sub)nanosecond pulse source to a corona plasma reactor

    Science.gov (United States)

    Huiskamp, T.; Beckers, F. J. C. M.; Hoeben, W. F. L. M.; van Heesch, E. J. M.; Pemen, A. J. M.

    2016-10-01

    In this paper we investigate the energy transfer from the pulses of a (sub)nanosecond pulse source to the plasma in a corona-plasma reactor. This energy transfer (or ‘matching’) should be as high as possible. We studied the effect of multiple parameters on matching, such as the reactor configuration, the pulse duration and amplitude and the energy density. The pulse reflection on the reactor interface has a significant influence on matching, and should be as low as possible to transfer the most energy into the reactor. We developed a multiple-wire inner conductor for the reactor which decreases the vacuum impedance of the reactor to decrease the pulse reflection on the reactor interface while maintaining a high electric field on the wire. The results were very encouraging and showed an energy transfer efficiency of over 90 percent. The matching results further show that there is only a small effect on the matching between different wire diameters. In addition, a long reactor and a long pulse result in the best matching due to the more intense plasma that is generated in these conditions. Finally, even without the multiple-wire reactor, we are able to achieve a very good matching (over 80 percent) between our pulse source and the reactor.

  17. Développement d'une source EUV plasma laser pour la micro-lithographie

    Science.gov (United States)

    Segers, M.; Bougeard, M.; Caprin, E.; Ceccotti, T.; Chichmanian, F.; Descamps, D.; Haltebourg, P.; Hergott, J.-F.; Hulin, S.; Normand, D.; Schmidt, M.; Sublemontier, O.

    2003-06-01

    Le Groupe des Applications Plasma (GAP) du CEA à Saclay participe au projet national PREUVE du Réseau Micro- et Nano-Technologies. Ce projet a été lancé fin 1999 pour réunir et développer les compétences en France sur la lithographie dans l'extrême ultraviolet (LEUV). Au sein de PREUVE, notre objectif a été le développement d'une source plasma laser dans I'EUV autour de 13nm afin de contribuer à la réalisation d'un premier banc d'essai pour la lithographie (BEL) en Europe. Afin de réaliser cette source, nous utilisons un plasma émetteur qui est produit par l'interaction d'un laser de type Nd :YAG sur un jet de gouttelettes de xénon. A la fin du projet PREUVE, cette source satisfait les principales spécifications et répond en particulier aux besoins en flux de photons EUV pour réaliser des tests d'insolation EUV avec le banc d'essai. Suite à ces résultats prometteurs, nous démarrons actuellement un projet industriel EXULITE avec nos partenaires du CEA, d'Alcatel et de Thalès sur le développement d'une source EUV de puissance pour des machines de lithographie de production. Ce projet se terminera en 2005.

  18. Development of liquid-jet laser-produced plasma light source for EUV lithography

    Science.gov (United States)

    Abe, Tamotsu; Suganuma, Takashi; Imai, Yousuke; Sugimoto, Yukihiko; Someya, Hiroshi; Hoshino, Hideo; Soumagne, Georg; Komori, Hiroshi; Mizoguchi, Hakaru; Endo, Akira; Toyoda, Koichi

    2003-06-01

    The Extreme UV Lithography System Development Association (EUVA) was established in Japan in May 2002 and is supported by the Ministry of Economy, Trade and Industry (METI). EUVA started the light soruce development in September 2002. This development is done by the assocaition members Gigaphoton, Ushio, Komatsu, Canon, Nikon, the National Institute of Advanced Industrial Sciecne and Technology (AIST) and several Japanese universities. The target of the four-year project is the development of a EUV light source with 10W clean focus point power. For the end of the fiscal year 2003 the development of a 4W EUV light source (clean focus point power) is planned. Both, Laser-Produced-Plasma (LPP) and Discharge-Produced-Plasma (DPP) EUV light sources are investigated at first. Our group at the EUVA Hiratsuka R&D Center is working on LPP sources. We are currently focusing on the development of a driver laser and a liquid Xenon plasma target. The laser is a Nd:YAG MOPA (Master Oscillator and Power Amplifier) system oscillating at 1064 nm. Average power, repetition rate and pulse duration of the laser system are 500 Watt, 10 kHa and 30nsec, respectively. The Xenon liquefication system operates at a maximum pressure of 5MPa and a temperature range between 160 K and 190 K. The pressure inside the vacuum chamber is below 0.1Pa during system operation. This paper presents the current status of the EUV system component development as well as first experimental results of generated EUV radiation.

  19. Laser plasma x-ray source for ultrafast time-resolved x-ray absorption spectroscopy.

    Science.gov (United States)

    Miaja-Avila, L; O'Neil, G C; Uhlig, J; Cromer, C L; Dowell, M L; Jimenez, R; Hoover, A S; Silverman, K L; Ullom, J N

    2015-03-01

    We describe a laser-driven x-ray plasma source designed for ultrafast x-ray absorption spectroscopy. The source is comprised of a 1 kHz, 20 W, femtosecond pulsed infrared laser and a water target. We present the x-ray spectra as a function of laser energy and pulse duration. Additionally, we investigate the plasma temperature and photon flux as we vary the laser energy. We obtain a 75 μm FWHM x-ray spot size, containing ∼10(6) photons/s, by focusing the produced x-rays with a polycapillary optic. Since the acquisition of x-ray absorption spectra requires the averaging of measurements from >10(7) laser pulses, we also present data on the source stability, including single pulse measurements of the x-ray yield and the x-ray spectral shape. In single pulse measurements, the x-ray flux has a measured standard deviation of 8%, where the laser pointing is the main cause of variability. Further, we show that the variability in x-ray spectral shape from single pulses is low, thus justifying the combining of x-rays obtained from different laser pulses into a single spectrum. Finally, we show a static x-ray absorption spectrum of a ferrioxalate solution as detected by a microcalorimeter array. Altogether, our results demonstrate that this water-jet based plasma source is a suitable candidate for laboratory-based time-resolved x-ray absorption spectroscopy experiments.

  20. Laser plasma x-ray source for ultrafast time-resolved x-ray absorption spectroscopy

    Directory of Open Access Journals (Sweden)

    L. Miaja-Avila

    2015-03-01

    Full Text Available We describe a laser-driven x-ray plasma source designed for ultrafast x-ray absorption spectroscopy. The source is comprised of a 1 kHz, 20 W, femtosecond pulsed infrared laser and a water target. We present the x-ray spectra as a function of laser energy and pulse duration. Additionally, we investigate the plasma temperature and photon flux as we vary the laser energy. We obtain a 75 μm FWHM x-ray spot size, containing ∼106 photons/s, by focusing the produced x-rays with a polycapillary optic. Since the acquisition of x-ray absorption spectra requires the averaging of measurements from >107 laser pulses, we also present data on the source stability, including single pulse measurements of the x-ray yield and the x-ray spectral shape. In single pulse measurements, the x-ray flux has a measured standard deviation of 8%, where the laser pointing is the main cause of variability. Further, we show that the variability in x-ray spectral shape from single pulses is low, thus justifying the combining of x-rays obtained from different laser pulses into a single spectrum. Finally, we show a static x-ray absorption spectrum of a ferrioxalate solution as detected by a microcalorimeter array. Altogether, our results demonstrate that this water-jet based plasma source is a suitable candidate for laboratory-based time-resolved x-ray absorption spectroscopy experiments.