WorldWideScience

Sample records for plasma plasma samples

  1. Surface studies of plasma processed Nb samples

    Energy Technology Data Exchange (ETDEWEB)

    Tyagi, Puneet V. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Spallation Neutron Source (SNS); Doleans, Marc [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Spallation Neutron Source (SNS); Hannah, Brian S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Spallation Neutron Source (SNS); Afanador, Ralph [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Spallation Neutron Source (SNS); Stewart, Stephen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Spallation Neutron Source (SNS); Mammosser, John [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Spallation Neutron Source (SNS); Howell, Matthew P [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Spallation Neutron Source (SNS); Saunders, Jeffrey W [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Spallation Neutron Source (SNS); Degraff, Brian D [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Spallation Neutron Source (SNS); Kim, Sang-Ho [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Spallation Neutron Source (SNS)

    2015-01-01

    Contaminants present at top surface of superconducting radio frequency (SRF) cavities can act as field emitters and restrict the cavity accelerating gradient. A room temperature in-situ plasma processing technology for SRF cavities aiming to clean hydrocarbons from inner surface of cavities has been recently developed at the Spallation Neutron Source (SNS). Surface studies of the plasma-processed Nb samples by Secondary ion mass spectrometry (SIMS) and Scanning Kelvin Probe (SKP) showed that the NeO2 plasma processing is very effective to remove carbonaceous contaminants from top surface and improves the surface work function by 0.5 to 1.0 eV.

  2. Biofouling development on plasma treated samples versus layers coated samples

    Science.gov (United States)

    Hnatiuc, B.; Exnar, P.; Sabau, A.; Spatenka, P.; Dumitrache, C. L.; Hnatiuc, M.; Ghita, S.

    2016-12-01

    Biofouling is the most important cause of naval corrosion. In order to reduce the Biofouling development on naval materials as steel or resin, different new methods have been tested. These methods could help to follow the new IMO environment reglementations and they could replace few classic operations before the painting of the small ships. The replacement of these operations means a reduction in maintenance costs. Their action must influence especially the first two steps of the Biofouling development, called Microfouling, that demand about 24 hours. This work presents the comparative results of the Biofouling development on two different classic naval materials, steel and resin, for three treated samples, immersed in sea water. Non-thermal plasma, produced by GlidArc technology, is applied to the first sample, called GD. The plasma treatment was set to 10 minutes. The last two samples, called AE9 and AE10 are covered by hydrophobic layers, prepared from a special organic-inorganic sol synthesized by sol-gel method. Theoretically, because of the hydrophobic properties, the Biofouling formation must be delayed for AE9 and AE10. The Biofouling development on each treated sample was compared with a witness non-treated sample. The microbiological analyses have been done for 24 hours by epifluorescence microscopy, available for one single layer.

  3. 51Cr-EDTA plasma clearance in severe renal failure determined by one plasma sample

    DEFF Research Database (Denmark)

    Kamper, A L; Nielsen, S L

    1989-01-01

    at zero-time was derived from injected dose and body surface area. This method might provide values 1.5 ml/min below or 0.8 ml/min above the established method of 51Cr-EDTA plasma clearance, which would be acceptable for clinical purposes. It is concluded that exact plasma clearance of 51Cr-EDTA in severe......Two hundred and thirty-four measurements of standard 51Cr-EDTA plasma clearance were made in 50 patients with severe chronic renal failure. Based on these data two calculation methods were attempted using one plasma sample drawn 24 h after injection of 51Cr-EDTA. One of the methods used the 'one...... sample clearance' formulas disregarding exact time of plasma sampling. This method might provide values 3.1 ml/min below or 2.9 ml/min above the established method of total 51Cr-EDTA plasma clearance, and would thus provide insufficient agreement. In the other method an estimate of plasma activity...

  4. Ion sampling and transport in Inductively Coupled Plasma Mass Spectrometry

    Science.gov (United States)

    Farnsworth, Paul B.; Spencer, Ross L.

    2017-08-01

    Quantitative accuracy and high sensitivity in inductively coupled plasma mass spectrometry (ICP-MS) depend on consistent and efficient extraction and transport of analyte ions from an inductively coupled plasma to a mass analyzer, where they are sorted and detected. In this review we examine the fundamental physical processes that control ion sampling and transport in ICP-MS and compare the results of theory and computerized models with experimental efforts to characterize the flow of ions through plasma mass spectrometers' vacuum interfaces. We trace the flow of ions from their generation in the plasma, into the sampling cone, through the supersonic expansion in the first vacuum stage, through the skimmer, and into the ion optics that deliver the ions to the mass analyzer. At each stage we consider idealized behavior and departures from ideal behavior that affect the performance of ICP-MS as an analytical tool.

  5. Blood sampling and hemolysis affect concentration of plasma metabolites

    DEFF Research Database (Denmark)

    Theil, Peter Kappel; Pedersen, Lene Juul; Jensen, Margit Bak;

    2012-01-01

    , a subset of samples from 24 sows fed twice daily in Exp. 1 was combined with data obtained from 30 sows sampled using jugular vein catheters. All sows in Exp. 2 were fed twice daily (0800 h and 1500 h) and blood samples collected repeatedly 1, 4, 11, and 23 h after morning feeding (other conditions were......Two experiments were carried out to reveal and quantify plasma metabolites that are sensitive to hemolysis and animal stress due to the blood sampling procedure (vein puncture vs. catheter). In Exp. 1, 48 sows were fed 4 diets either once (0800 h) or twice daily (0800 h and 1500 h) in a crossover...... design and blood was collected after restraint via vein puncture 1, 4, 11, and 23 h after morning feeding. Plasma samples were categorized as without or with minor or major hemolysis [clear (n = 218), yellow (n = 97), or red (n = 37)] upon centrifugation. Plasma NEFA (P

  6. Metabolomic Quality Assessment of EDTA Plasma and Serum Samples.

    Science.gov (United States)

    Malm, Linus; Tybring, Gunnel; Moritz, Thomas; Landin, Britta; Galli, Joakim

    2016-10-01

    Handling and processing of blood can significantly alter the molecular composition and consistency of biobank samples and can have a major impact on the identification of biomarkers. It is thus crucial to identify tools to determine the quality of samples to be used in biomarker discovery studies. In this study, a non-targeted gas chromatography/time-of-flight mass spectrometry (GC-TOFMS) metabolomic strategy was used with the aim of identifying quality markers for serum and plasma biobank collections lacking proper documentation of preanalytical handling. The effect of postcentrifugation delay was examined in serum stored in tubes with gel separation plugs and ethylenediaminetetraacetic acid (EDTA) plasma in tubes with or without gel separation plugs. The change in metabolic pattern was negligible in all sample types processed within 3 hours after centrifugation regardless of whether the samples were kept at 4°C or 22°C. After 8 and 24 hours postcentrifugation delay before aliquoting, there was a pronounced increase in the number of affected metabolites, as well as in the magnitude of the observed changes. No protective effect on the metabolites was observed in gel-separated EDTA plasma samples. In a separate series of experiments, lactate and glucose levels were determined in plasma to estimate the effect of precentrifugation delay. This separate experiment indicates that the lactate to glucose ratio may serve as a marker to identify samples with delayed time to centrifugation. Although our data from the untargeted GC-TOFMS analysis did not identify any specific markers, we conclude that plasma and serum metabolic profiles remain quite stable when plasma and serum are centrifuged and separated from the blood cells within 3 hours.

  7. Experimental breakdown of selected anodized aluminum samples in dilute plasmas

    Science.gov (United States)

    Grier, Norman T.; Domitz, Stanley

    1992-01-01

    Anodized aluminum samples representative of Space Station Freedom structural material were tested for electrical breakdown under space plasma conditions. In space, this potential arises across the insulating anodized coating when the spacecraft structure is driven to a negative bias relative to the external plasma potential due to plasma-surface interaction phenomena. For anodized materials used in the tests, it was found that breakdown voltage varied from 100 to 2000 volts depending on the sample. The current in the arcs depended on the sample, the capacitor, and the voltage. The level of the arc currents varied from 60 to 1000 amperes. The plasma number density varied from 3 x 10 exp 6 to 10 exp 3 ions per cc. The time between arcs increased as the number density was lowered. Corona testing of anodized samples revealed that samples with higher corona inception voltage had higher arcing inception voltages. From this it is concluded that corona testing may provide a method of screening the samples.

  8. Reproducibility of Circulating MicroRNAs in Stored Plasma Samples.

    Directory of Open Access Journals (Sweden)

    Monica L Bertoia

    Full Text Available Most studies of microRNA (miRNA and disease have examined tissue-specific expression in limited numbers of samples. The presence of circulating miRNAs in plasma samples provides the opportunity to examine prospective associations between miRNA expression and disease in initially healthy individuals. However, little data exist on the reproducibility of miRNAs in stored plasma.We used Real-Time PCR to measure 61 pre-selected microRNA candidates in stored plasma. Coefficients of variation (CVs were used to assess inter-assay reliability (n = 15 and within-person stability over one year (n = 80. Intraclass correlation coefficients (ICCs and polychoric correlation coefficients were used to assess within-person stability and delayed processing reproducibility (whole blood stored at 4°C for 0, 24 and 48 hours; n = 12 samples.Of 61 selected miRNAs, 23 were detected in at least 50% of samples and had average CVs below 20% for inter-assay reproducibility and 31 for delayed processing reproducibility. Ten miRNAs were detected in at least 50% of samples, had average CVs below 20% and had ICCs above 0.4 for within-person stability over 1-2 years, six of which satisfied criteria for both interassay reproducibility and short-term within-person stability (miR-17-5p, -191-5p, -26a-5p, -27b-3p, -320a, and -375 and two all three types of reproducibility (miR-27b-3p and -26a-5p. However, many miRNAs with acceptable average CVs had high maximum CVs, most had low expression levels, and several had low ICCs with delayed processing.About a tenth of miRNAs plausibly related to chronic disease were reliably detected in stored samples of healthy adults.

  9. Nanoliter viscometer for analyzing blood plasma and other liquid samples.

    Science.gov (United States)

    Srivastava, Nimisha; Davenport, Robertson D; Burns, Mark A

    2005-01-15

    We have developed a microfabricated nanoliter capillary viscometer that quickly, easily, and inexpensively measures the viscosity of liquids. The measurement of viscosity is based on capillary pressure-driven flow inside microfluidic channels (depth approximately 30 microm and width approximately 300 microm). Accurate and precise viscosity measurements can be made in less than 100 s while using only 600 nL of liquid sample. The silicon-glass hybrid device (18 mm by 15 mm) contains on-chip components that measure the driving capillary pressure difference and the relevant geometrical parameters; these components make the nanoliter viscometer completely self-calibrating, robust, and easy to use. Several different microfabricated viscometers were tested using solutions with viscosities ranging from 1 to 5 cP, a range relevant to biological fluids (urine, blood, blood plasma, etc.). Blood plasma samples collected from patients with the symptoms of hyperviscosity syndrome were tested on the nanoliter capillary viscometer to an accuracy of 3%. Such self-calibrating nanoliter viscometers may have widespread applications in chemical, biological, and medical laboratories as well as in personal health care.

  10. Accurate and precise plasma clearance measurement using four 99mTc-DTPA plasma samples over 4 h

    OpenAIRE

    Wanasundara, Surajith N.; Wesolowski, Michal J.; Barnfield, Mark C.; Waller, Michael L.; Murray, Anthony W.; Burniston, Maria T.; Babyn, Paul S.; Wesolowski, Carl A.

    2015-01-01

    Objectives Glomerular filtration rate can be measured as the plasma clearance (CL) of a glomerular filtration rate marker despite body fluid disturbances using numerous, prolonged time samples. We desire a simplified technique without compromised accuracy and precision. Materials and methods We compared CL values derived from two plasma concentration curve area methods – (a) biexponential fitting [CL (E2)] and (b) Tikhonov adaptively regularized gamma variate fitting [CL (Tk-GV)] – for 4 vers...

  11. Plasma turbulence

    Energy Technology Data Exchange (ETDEWEB)

    Horton, W. [Univ. of Texas, Austin, TX (United States). Inst. for Fusion Studies; Hu, G. [Globalstar LP, San Jose, CA (United States)

    1998-07-01

    The origin of plasma turbulence from currents and spatial gradients in plasmas is described and shown to lead to the dominant transport mechanism in many plasma regimes. A wide variety of turbulent transport mechanism exists in plasmas. In this survey the authors summarize some of the universally observed plasma transport rates.

  12. Plasma harmonics

    CERN Document Server

    Ganeev, Rashid A

    2014-01-01

    Preface; Why plasma harmonics? A very brief introduction Early stage of plasma harmonic studies - hopes and frustrations New developments in plasma harmonics studies: first successes Improvements of plasma harmonics; Theoretical basics of plasma harmonics; Basics of HHG Harmonic generation in fullerenes using few-cycle pulsesVarious approaches for description of observed peculiarities of resonant enhancement of a single harmonic in laser plasmaTwo-colour pump resonance-induced enhancement of odd and even harmonics from a tin plasmaCalculations of single harmonic generation from Mn plasma;Low-o

  13. Impact of hemolysis during sample collection: how different is drug concentration in hemolyzed plasma from that of normal plasma?

    Science.gov (United States)

    Tan, Aimin; Gagné, Sébastien; Lévesque, Isabelle A; Lachance, Sylvain; Boudreau, Nadine; Lévesque, Ann

    2012-07-15

    Hemolysis is a common phenomenon in clinical studies. Despite the growing interest in hemolysis matrix effect, how hemolysis impacts the representability of hemolyzed plasma samples was rarely evaluated. The purpose of this research is to perform such an evaluation by theoretical consideration and experiment. A formula for estimating the impact is proposed, which includes the degree of hemolysis and the drug's red blood cell (RBC): plasma concentration ratio. The impact of hemolysis on the representability of hemolyzed plasma samples is compound-dependant. Given the same degree of hemolysis, the stronger a drug binds to RBCs, the more significant the impact of hemolysis. For a drug with high affinity to RBCs, the results of hemolyzed plasma samples may not be useful even though they are accurate. There is an overall agreement between theoretical predication and experimental results. Among the ten different drug compounds tested, only methazolamide, which binds strongly to RBCs, showed significant change in plasma concentration due to hemolysis. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Controls to validate plasma samples for cell free DNA quantification

    DEFF Research Database (Denmark)

    Pallisgaard, Niels; Spindler, Karen-Lise Garm; Andersen, Rikke Fredslund;

    2015-01-01

    Recent research has focused on the utility of cell free DNA (cfDNA) in serum and plasma for clinical application, especially in oncology. The literature holds promise of cfDNA as a valuable tumour marker to be used for treatment selection, monitoring and follow-up. The results, however, are diver...

  15. Monte Carlo Sampling of Negative-temperature Plasma States

    Energy Technology Data Exchange (ETDEWEB)

    John A. Krommes; Sharadini Rath

    2002-07-19

    A Monte Carlo procedure is used to generate N-particle configurations compatible with two-temperature canonical equilibria in two dimensions, with particular attention to nonlinear plasma gyrokinetics. An unusual feature of the problem is the importance of a nontrivial probability density function R0(PHI), the probability of realizing a set {Phi} of Fourier amplitudes associated with an ensemble of uniformly distributed, independent particles. This quantity arises because the equilibrium distribution is specified in terms of {Phi}, whereas the sampling procedure naturally produces particles states gamma; {Phi} and gamma are related via a gyrokinetic Poisson equation, highly nonlinear in its dependence on gamma. Expansion and asymptotic methods are used to calculate R0(PHI) analytically; excellent agreement is found between the large-N asymptotic result and a direct numerical calculation. The algorithm is tested by successfully generating a variety of states of both positive and negative temperature, including ones in which either the longest- or shortest-wavelength modes are excited to relatively very large amplitudes.

  16. Dusty plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Fortov, Vladimir E; Khrapak, Aleksei G; Molotkov, Vladimir I; Petrov, Oleg F [Institute for High Energy Densities, Associated Institute for High Temperatures, Russian Academy of Sciences, Moscow (Russian Federation); Khrapak, Sergei A [Max-Planck-Institut fur Extraterrestrische Physik, Garching (Germany)

    2004-05-31

    The properties of dusty plasmas - low-temperature plasmas containing charged macroparticles - are considered. The most important elementary processes in dusty plasmas and the forces acting on dust particles are investigated. The results of experimental and theoretical investigations of different states of strongly nonideal dusty plasmas - crystal-like, liquid-like, gas-like - are summarized. Waves and oscillations in dusty plasmas, as well as their damping and instability mechanisms, are studied. Some results on dusty plasma investigated under microgravity conditions are presented. New directions of experimental research and potential applications of dusty plasmas are discussed. (reviews of topical problems)

  17. New high temperature plasmas and sample introduction systems for analytical atomic emission and mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Montaser, A.

    1992-01-01

    New high temperature plasmas and new sample introduction systems are explored for rapid elemental and isotopic analysis of gases, solutions, and solids using mass spectrometry and atomic emission spectrometry. Emphasis was placed on atmospheric pressure He inductively coupled plasmas (ICP) suitable for atomization, excitation, and ionization of elements; simulation and computer modeling of plasma sources with potential for use in spectrochemical analysis; spectroscopic imaging and diagnostic studies of high temperature plasmas, particularly He ICP discharges; and development of new, low-cost sample introduction systems, and examination of techniques for probing the aerosols over a wide range. Refs., 14 figs. (DLC)

  18. LC-MS analysis of the plasma metabolome–a novel sample preparation strategy

    DEFF Research Database (Denmark)

    Skov, Kasper; Hadrup, Niels; Smedsgaard, Jørn

    2015-01-01

    of plasma samples: The first is protein precipitation; the second is protein precipitation followed by solid phase extraction with sub-fractionation into three sub-samples; a phospholipid, a lipid and a polar sub-fraction. Molecular feature extraction of the data files from LC-qTOF analysis of the samples......Blood plasma is a well-known body fluid often analyzed in studies on the effects of toxic compounds as physiological or chemical induced changes in the mammalian body are reflected in the plasma metabolome. Sample preparation prior to LC-MS based analysis of the plasma metabolome is a challenge...... as plasma contains compounds with very different properties. Besides, proteins, which usually are precipitated with organic solvent, phospholipids, are known to cause ion suppression in electrospray mass spectrometry. We have compared two different sample preparation techniques prior to LC-qTOF analysis...

  19. plasma treatment

    Directory of Open Access Journals (Sweden)

    Puač Nevena

    2014-11-01

    Full Text Available In this paper we will present results for plasma sterilization of planktonic samples of two reference strains of bacteria, Pseudomonas aeruginosa ATCC 27853 and Enterococcus faecalis ATCC 29212. We have used a plasma needle as a source of non-equilibrium atmospheric plasma in all treatments. This device is already well characterized by OES, derivative probes and mass spectrometry. It was shown that power delivered to the plasma is bellow 2 W and that it produces the main radical oxygen and nitrogen species believed to be responsible for the sterilization process. Here we will only present results obtained by electron paramagnetic resonance which was used to detect the OH, H and NO species. Treatment time and power delivered to the plasma were found to have the strongest influence on sterilization. In all cases we have observed a reduction of several orders of magnitude in the concentration of bacteria and for the longest treatment time complete eradication. A more efficient sterilization was achieved in the case of gram negative bacteria.

  20. Plasma waves

    CERN Document Server

    Swanson, DG

    1989-01-01

    Plasma Waves discusses the basic development and equations for the many aspects of plasma waves. The book is organized into two major parts, examining both linear and nonlinear plasma waves in the eight chapters it encompasses. After briefly discussing the properties and applications of plasma wave, the book goes on examining the wave types in a cold, magnetized plasma and the general forms of the dispersion relation that characterize the waves and label the various types of solutions. Chapters 3 and 4 analyze the acoustic phenomena through the fluid model of plasma and the kinetic effects. Th

  1. Plasma astrophysics

    CERN Document Server

    Kaplan, S A; ter Haar, D

    2013-01-01

    Plasma Astrophysics is a translation from the Russian language; the topics discussed are based on lectures given by V.N. Tsytovich at several universities. The book describes the physics of the various phenomena and their mathematical formulation connected with plasma astrophysics. This book also explains the theory of the interaction of fast particles plasma, their radiation activities, as well as the plasma behavior when exposed to a very strong magnetic field. The text describes the nature of collective plasma processes and of plasma turbulence. One author explains the method of elementary

  2. The effect of sample size on fresh plasma thromboplastin ISI determination

    DEFF Research Database (Denmark)

    Poller, L; Van Den Besselaar, A M; Jespersen, J;

    1999-01-01

    The possibility of reduction of numbers of fresh coumarin and normal plasmas has been studied in a multicentre manual prothrombin (PT) calibration of high international sensitivity index (ISI) rabbit and low ISI human reference thromboplastins at 14 laboratories. The number of calibrant plasmas...... was reduced progressively by a computer program which generated random numbers to provide 1000 different selections for each reduced sample at each participant laboratory. Results were compared with those of the full set of 20 normal and 60 coumarin plasma calibrations. With the human reagent, 20 coumarins...... and seven normals still achieved the W.H.O. precision limit (3% CV of the slope), but with the rabbit reagent reduction coumarins with 17 normal plasmas led to unacceptable CV. Little reduction of numbers from the full set of 80 fresh plasmas appears advisable. For maximum confidence, when calibrating...

  3. Simulation of rarefied low pressure RF plasma flow around the sample

    Science.gov (United States)

    Zheltukhin, V. S.; Shemakhin, A. Yu

    2017-01-01

    The paper describes a mathematical model of the flow of radio frequency plasma at low pressure. The hybrid mathematical model includes the Boltzmann equation for the neutral component of the RF plasma, the continuity and the thermal equations for the charged component. Initial and boundary conditions for the corresponding equations are described. The electron temperature in the calculations is 1-4 eV, atoms temperature in the plasma clot is (3-4) • 103 K, in the plasma jet is (3.2-10) • 102 K, the degree of ionization is 10-7-10-5, electron density is 1015-1019 m-3. For calculations plasma parameters is developed soft package on C++ program language, that uses the OpenFOAM library package. Simulations for the vacuum chamber in the presence of a sample and the free jet flow were carried out.

  4. Proteomic biomarker discovery in 1000 human plasma samples with mass spectrometry

    DEFF Research Database (Denmark)

    Cominetti, Ornella; Núñez Galindo, Antonio; Corthésy, John

    2016-01-01

    the quality of the MS data and provided descriptive statistics. The data set was interrogated for proteins with most stable expression levels in that set of plasma samples. We evaluated standard clinical variables that typically impact forthcoming results and assessed body mass index-associated and gender......-specific proteins at two time points. We demonstrate that analyzing a large number of human plasma samples for biomarker discovery with MS using isobaric tagging is feasible, providing robust and consistent biological results....

  5. Analysis of whole blood samples with low gas flow inductively coupled plasma-optical emission spectrometry.

    Science.gov (United States)

    Nowak, Sascha; Künnemeyer, Jens; Terborg, Lydia; Trümpler, Stefan; Günsel, Andreas; Wiesmüller, Gerhard A; Karst, Uwe; Buscher, Wolfgang

    2015-01-01

    Low gas flow ICP-OES with a total argon consumption below 0.7 L/min is introduced for the analysis of trace elements in blood samples to investigate the influence of samples containing an organic solvent in a demanding matrix on the performance of this plasma for the first time. Therefore, gadolinium was determined in human plasma samples and mercury in red blood cells, human plasma, and precipitated plasma protein fraction. Limits of detection (LOD) were determined to be in the low microgram per liter range for the analytes and the accuracy of the method was assessed by comparison with a conventional Fassel-type torch-based ICP-OES. It was proven that the low gas flow ICP-OES leads to comparable results with the instrument based on the Fassel-type torch.

  6. Plasma Antenna

    OpenAIRE

    N M Vijay

    2014-01-01

    The fundamental base of plasma antenna is the use of an ionized medium as a conductor. The plasma antenna is a radiofrequency antenna formed by a plasma columns, Filaments or sheets, which are excited by a surface wave. The relevance of this device is how rapidly it can be turned on and off, only applying an electrical pulse. Besides its wide carrier frequency, the great directivity and controllable antenna shape. Otherwise a disadvantage is that it needs energy to be ionized....

  7. Plasma physics

    CERN Document Server

    Drummond, James E

    2013-01-01

    A historic snapshot of the field of plasma physics, this fifty-year-old volume offers an edited collection of papers by pioneering experts in the field. In addition to assisting students in their understanding of the foundations of classical plasma physics, it provides a source of historic context for modern physicists. Highly successful upon its initial publication, this book was the standard text on plasma physics throughout the 1960s and 70s.Hailed by Science magazine as a ""well executed venture,"" the three-part treatment ranges from basic plasma theory to magnetohydrodynamics and microwa

  8. Separation of proteins from human plasma by sample displacement chromatography in hydrophobic interaction mode

    OpenAIRE

    Josic, Djuro; Breen, Lucas; Clifton, James; Gajdosik, Martina Srajer; Gaso-Sokac, Dajana; Rucevic, Marijana; Müller, Egbert

    2012-01-01

    Sample displacement chromatography (SDC) in reversed-phase and ion-exchange modes was introduced approximately twenty years ago. This method was first used for the preparative purification of peptides and proteins. Recently, SDC in ion-exchange mode was also successfully used for enrichment of low abundance proteins from human plasma. In this paper, the use of SDC for the separation of plasma proteins in hydrophobic interaction mode is demonstrated. By use of two or more columns coupled in se...

  9. Analysis of bioethanol samples through Inductively Coupled Plasma Mass Spectrometry with a total sample consumption system

    Science.gov (United States)

    Sánchez, Carlos; Lienemann, Charles-Philippe; Todolí, Jose-Luis

    2016-10-01

    Bioethanol real samples have been directly analyzed through ICP-MS by means of the so called High Temperature Torch Integrated Sample Introduction System (hTISIS). Because bioethanol samples may contain water, experiments have been carried out in order to determine the effect of ethanol concentration on the ICP-MS response. The ethanol content studied went from 0 to 50%, because higher alcohol concentrations led to carbon deposits on the ICP-MS interface. The spectrometer default spray chamber (double pass) equipped with a glass concentric pneumatic micronebulizer has been taken as the reference system. Two flow regimes have been evaluated: continuous sample aspiration at 25 μL min- 1 and 5 μL air-segmented sample injection. hTISIS temperature has been shown to be critical, in fact ICP-MS sensitivity increased with this variable up to 100-200 °C depending on the solution tested. Higher chamber temperatures led to either a drop in signal or a plateau. Compared with the reference system, the hTISIS improved the sensitivities by a factor included within the 4 to 8 range while average detection limits were 6 times lower for the latter device. Regarding the influence of the ethanol concentration on sensitivity, it has been observed that an increase in the temperature was not enough to eliminate the interferences. It was also necessary to modify the torch position with respect to the ICP-MS interface to overcome them. This fact was likely due to the different extent of ion plasma radial diffusion encountered as a function of the matrix when working at high chamber temperatures. When the torch was moved 1 mm plasma down axis, ethanolic and aqueous solutions provided statistically equal sensitivities. A preconcentration procedure has been applied in order to validate the methodology. It has been found that, under optimum conditions from the point of view of matrix effects, recoveries for spiked samples were close to 100%. Furthermore, analytical concentrations for real

  10. Effects of anesthesia and blood sampling techniques on plasma metabolites and corticosterone in the rat.

    Science.gov (United States)

    Arnold, Myrtha; Langhans, Wolfgang

    2010-04-19

    Blood is routinely sampled from laboratory animals in biomedical research, and many of the commonly applied sampling techniques require anesthesia. Acute effects of many sampling and anesthesia procedures may confound the results, but those effects are incompletely characterized. We here compare the effects of four common anesthesia procedures (inhalation anesthesia with ether (EA) or isoflurane (IA) and intraperitoneal injection anesthesia with xylazin/ketamine (XKA) or medetomidine/midazolam/fentanyl (MMFA)) on plasma concentrations of glucose, lactate, non-esterified fatty acids (NEFAs), and corticosterone in blood obtained from a previously implanted jugular vein (JV) catheter with the effect of JV blood sampling from non-anesthetized, freely-moving rats (JV-NA). Also, we included in the comparison two other blood sampling procedures usually performed without anesthesia (NA), i.e., puncture of the saphenic vein (SV) and tail incision (TI). Whereas the control procedure (JV-NA) did not significantly affect any of the target parameters, plasma glucose increased from 14 (JV-IA) to 44 (JV-MMFA) % (all Ps=0.05 when compared with the control procedure) in all blood samples collected in anesthesia and was 12 and 14% lower (both Pssamples, respectively. Plasma lactate increased from 74 (JV-IA) to 226% (SV-NA) (all Pssampling and anesthesia procedures except for JV-XKA and JV-MMF. Plasma NEFAs increased to 52% (P0.05). Finally, only the JV-EA and the JV-MMFA procedures increased plasma corticosterone (+525 and +353%, respectively, both Pssampling procedures can have profound acute effects on plasma metabolite and hormone concentrations. This must be considered for the design and interpretation of blood sampling experiments in laboratory animals. (c) 2010. Published by Elsevier Inc.

  11. Inductively coupled plasma mass spectrometry in the analysis of biological samples and pharmaceutical drugs

    Science.gov (United States)

    Ossipov, K.; Seregina, I. F.; Bolshov, M. A.

    2016-04-01

    Inductively coupled plasma mass spectrometry (ICP-MS) is widely used in the analysis of biological samples (whole blood, serum, blood plasma, urine, tissues, etc.) and pharmaceutical drugs. The shortcomings of this method related to spectral and non-spectral interferences are manifested in full measure in determination of the target analytes in these complex samples strongly differing in composition. The spectral interferences are caused by similarity of masses of the target component and sample matrix components. Non-spectral interferences are related to the influence of sample matrix components on the physicochemical processes taking place during formation and transportation of liquid sample aerosols into the plasma, on the value and spatial distribution of plasma temperature and on the transmission of the ion beam from the interface to mass spectrometer detector. The review is devoted to analysis of different mechanisms of appearance of non-spectral interferences and to ways for their minimization or elimination. Special attention is paid to the techniques of biological sample preparation, which largely determine the mechanisms of the influence of sample composition on the results of element determination. The ways of lowering non-spectral interferences by instrumental parameter tuning and application of internal standards are considered. The bibliography includes 189 references.

  12. Plasma chromograninx

    DEFF Research Database (Denmark)

    Goetze, Jens P; Hilsted, Linda M; Rehfeld, Jens F

    2014-01-01

    Cardiovascular risk assessment remains difficult in elderly patients. We examined whether chromogranin A (CgA) measurement in plasma may be valuable in assessing risk of death in elderly patients with symptoms of heart failure in a primary care setting. A total of 470 patients (mean age 73 years......) were followed for 10 years. For CgA plasma measurement, we used a two-step method including a screening test and a confirmative test with plasma pre-treatment with trypsin. Cox multivariable proportional regression and receiver-operating curve (ROC) analyses were used to assess mortality risk...... of follow-up showed significant additive value of CgA confirm measurements compared with NT-proBNP and clinical variables. CgA measurement in the plasma of elderly patients with symptoms of heart failure can identify those at increased risk of short- and long-term mortality....

  13. Plasma Cleaning

    Science.gov (United States)

    Hintze, Paul E.

    2016-01-01

    NASA's Kennedy Space Center has developed two solvent-free precision cleaning techniques: plasma cleaning and supercritical carbon dioxide (SCCO2), that has equal performance, cost parity, and no environmental liability, as compared to existing solvent cleaning methods.

  14. Plasma confinement

    CERN Document Server

    Hazeltine, R D

    2003-01-01

    Detailed and authoritative, this volume examines the essential physics underlying international research in magnetic confinement fusion. It offers readable, thorough accounts of the fundamental concepts behind methods of confining plasma at or near thermonuclear conditions. Designed for a one- or two-semester graduate-level course in plasma physics, it also represents a valuable reference for professional physicists in controlled fusion and related disciplines.

  15. Liquid chromatography-mass spectrometric determination of rufinamide in low volume plasma samples.

    Science.gov (United States)

    Gáll, Zsolt; Vancea, Szende; Dogaru, Maria T; Szilágyi, Tibor

    2013-12-01

    Quantification of rufinamide in plasma was achieved using a selective and sensitive liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) method. The chromatographic separation was achieved on a reversed phase column (Zorbax SB-C18 100mm×3mm, 3.5μm) under isocratic conditions. The mobile phase consisted of a mixture of water containing 0.1% formic acid and methanol (50:50, v/v). The mass spectrometric detection of the analyte was in multiple reaction monitoring mode (MRM) using an electrospray positive ionization (ESI positive). The monitored ions were 127m/z derived from 239m/z rufinamide and 108m/z derived from 251m/z the internal standard (lacosamide). Protein precipitation with methanol was applied for sample preparation using only 50μl aliquots. The concentration range was 40-2000ng/ml for rufinamide in plasma. The limit of detection was 1.25ng/ml and the lower limit of quantification was established at 5ng/ml rufinamide concentration. Selectivity and matrix effect was verified using individual human, rat and rabbit plasma samples. Short-term, post-preparative and freeze-thaw stability was also investigated. The proposed method provides accuracy, precision and high-throughput (short runtime 4.5min) for quantitative determination of rufinamide in plasma. This is the first reported liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for analysis of rufinamide from low volume plasma samples. The LC-MS/MS method was validated according to the current official guidelines and can be applied to accurately measure rufinamide level of large number of plasma samples from clinical studies or therapeutic drug monitoring.

  16. Measurement and Comparison of Organic Compound Concentrations in Plasma, Whole Blood, and Dried Blood Spot Samples.

    Science.gov (United States)

    Batterman, Stuart A; Chernyak, Sergey; Su, Feng-Chiao

    2016-01-01

    The preferred sampling medium for measuring human exposures of persistent organic compounds (POPs) is blood, and relevant sample types include whole blood, plasma, and dried blood spots (DBS). Because information regarding the performance and comparability of measurements across these sample types is limited, it is difficult to compare across studies. This study evaluates the performance of POP measurements in plasma, whole blood and DBS, and presents the distribution coefficients needed to convert concentrations among the three sample types. Blood samples were collected from adult volunteers, along with demographic and smoking information, and analyzed by GC/MS for organochlorine pesticides (OCPs), chlorinated hydrocarbons (CHCs), polychlorinated biphenyls (PCBs), and brominated diphenyl ethers (PBDEs). Regression models were used to evaluate the relationships between the sample types and possible effects of personal covariates. Distribution coefficients also were calculated using physically-based models. Across all compounds, concentrations in plasma were consistently the highest; concentrations in whole blood and DBS samples were comparable. Distribution coefficients for plasma to whole blood concentrations ranged from 1.74 to 2.26 for pesticides/CHCs, averaged 1.69 ± 0.06 for the PCBs, and averaged 1.65 ± 0.03 for the PBDEs. Regression models closely fit most chemicals (R (2) > 0.80), and whole blood and DBS samples generally showed very good agreement. Distribution coefficients estimated using biologically-based models were near one and did not explain the observed distribution. Among the study population, median concentrations of several pesticides/CHCs and PBDEs exceeded levels reported in the 2007-2008 National Health and Nutrition Examination Survey, while levels of other OCPs and PBDEs were comparable or lower. Race and smoking status appeared to slightly affect plasma/blood concentration ratios for several POPs. The experimentally

  17. Measurement and Comparison of Organic Compound Concentrations in Plasma, Whole Blood and Dried Blood Spot Samples

    Directory of Open Access Journals (Sweden)

    Stuart A Batterman

    2016-04-01

    Full Text Available The preferred sampling medium for measuring human exposures of persistent organic compounds (POPs is blood, and relevant sample types include whole blood, plasma, and dried blood spots (DBS. Because information regarding the performance and comparability of measurements across these sample types is limited, it is difficult to compare across studies. This study evaluates the performance of POP measurements in plasma, whole blood and DBS, and presents the distribution coefficients needed to convert concentrations among the three sample types. Blood samples were collected from adult volunteers, along with demographic and smoking information, and analyzed by GC/MS for organochlorine pesticides (OCPs, chlorinated hydrocarbons (CHCs, polychlorinated biphenyls (PCBs, and brominated diphenyl ethers (PBDEs. Regression models were used to evaluate the relationships between the sample types and possible effects of personal covariates. Distribution coefficients also were calculated using physically-based models.Across all compounds, concentrations in plasma were consistently the highest; concentrations in whole blood and DBS samples were comparable. Distribution coefficients for plasma to whole blood concentrations ranged from 1.74 to 2.26 for pesticides/CHCs, averaged 1.69 ± 0.06 for the PCBs, and averaged 1.65 ± 0.03 for the PBDEs. Regression models closely fit most chemicals (R2 > 0.80, and whole blood and DBS samples generally showed very good agreement. Distribution coefficients estimated using biologically-based models were near one and did not explain the observed distribution. Among the study population, median concentrations of several pesticides/CHCs and PBDEs exceeded levels reported in the 2007-2008 National Health and Nutrition Examination Survey, while levels of other OCPs and PBDEs were comparable or lower. Race and smoking status appeared to slightly affect plasma/blood concentration ratios for several POPs. The experimentally

  18. Effects of blood sample handling procedures on measurable inflammatory markers in plasma, serum and dried blood spot samples

    DEFF Research Database (Denmark)

    Skogstrand, K.; Thorsen, P.; Vogel, I.

    2008-01-01

    of whole blood samples at low temperatures and rapid isolation of plasma and serum. Effects of different handling procedures for all markers studied are given. DBSS proved to be a robust and convenient way to handle samples for immunoassay analysis of inflammatory markers in whole blood Udgivelsesdato......The interests in monitoring inflammation by immunoassay determination of blood inflammatory markers call for information on the stability of these markers in relation to the handling of blood samples. The increasing use of stored biobank samples for such ventures that may have been collected...... and stored for other purposes, justifies the study hereof. Blood samples were stored for 0, 4, 24, and 48 h at 4 degrees C, room temperature (RT), and at 35 degrees C, respectively, before they were separated into serum or plasma and frozen. Dried blood spot samples (DBSS) were stored for 0, 1, 2, 3, 7...

  19. New high temperature plasmas and sample introduction systems for analytical atomic emission and mass spectrometry

    Science.gov (United States)

    Montaser, A.

    This research follows a multifaceted approach, from theory to practice, to the investigation and development of novel helium plasmas, sample introduction systems, and diagnostic techniques for atomic and mass spectrometries. During the period January 1994 - December 1994, four major sets of challenging research programs were addressed that each included a number of discrete but complementary projects: (1) The first program is concerned with fundamental and analytical investigations of novel atmospheric-pressure helium inductively coupled plasmas (He ICPS) that are suitable for the atomization-excitation-ionization of elements, especially those possessing high excitation and ionization energies, for the purpose of enhancing sensitivity and selectivity of analytical measurements. (2) The second program includes simulation and computer modeling of He ICPS. The aim is to ease the hunt for new helium plasmas by predicting their structure and fundamental and analytical properties, without incurring the enormous cost for extensive experimental studies. (3) The third program involves spectroscopic imaging and diagnostic studies of plasma discharges to instantly visualize their prevailing structures, to quantify key fundamental properties, and to verify predictions by mathematical models. (4) The fourth program entails investigation of new, low-cost sample introduction systems that consume micro- to nanoliter quantity of sample solution in plasma spectrometries. A portion of this research involves development and applications of novel diagnostic techniques suitable for probing key fundamental properties of aerosol prior to and after injection into high-temperature plasmas. These efforts, still in progress, collectively offer promise of solving singularly difficult analytical problems that either exist now or are likely to arise in the future in the various fields of energy generation, environmental pollution, material science, biomedicine and nutrition.

  20. Efficient discrimination and removal of phospholipids during electromembrane extraction from human plasma samples

    DEFF Research Database (Denmark)

    Vårdal, Linda; Gjelstad, Astrid; Huang, Chuixiu

    2017-01-01

    AIM: For the first time, extracts obtained from human plasma samples by electromembrane extraction (EME) were investigated comprehensively with particular respect to phospholipids using ultra-high-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS). Thhe purpose was to invest...

  1. Measurement of glomerular filtration rate in adults: accuracy of five single-sample plasma clearance methods

    DEFF Research Database (Denmark)

    Rehling, M; Rabøl, A

    1989-01-01

    After an intravenous injection of a tracer that is removed from the body solely by filtration in the kidneys, the glomerular filtration rate (GFR) can be determined from its plasma clearance. The method requires a great number of blood samples but collection of urine is not needed. In the present...

  2. Effects of fruit and vegetable consumption on total antioxidant capacity of fasting and postprandial plasma samples

    DEFF Research Database (Denmark)

    Ravn-Haren, Gitte; Dragsted, L. O.; Pedersen, A.

    2001-01-01

    Fruits and vegetables are known to protect against cancer and heart disease. This is often ascribed to their high content of antioxidants. We have therefore tested whether a daily intake of fruits and vegetables corresponding to the recommended 600 g had any effect on the antioxidant activity of ...... of fasting and postprandial plasma samples. Antioxidant activity was determined by the Trolox Equivalent Antioxidant Capacity (TEAC) assay and the Ferric Reducing Ability of Plasma (FRAP) assay, which have been reported to be affected by the presence of dietary antioxidants....

  3. Development of a simple device for processing whole-blood samples into measured aliquots of plasma.

    Science.gov (United States)

    Burtis, C A; Johnson, W F; Walker, W A

    1986-09-01

    A capillary processor and aliquoter has been designed and fabricated that is capable of accepting aliquots of whole blood and automatically processing them into discrete aliquots of plasma. The device consists of two disks, each of which contains 16 individual capillaries and a processing rotor. One disk accepts larger capillaries that hold approximately 100 microL of whole blood each. The second disk accepts 2.54-cm-long precision capillaries of various internal diameters, which provide exact sample volumes from 1 to 10 microL. The processing rotor contains 16 individual compartments and chambers to accept both disks. Applying centrifugal force transfers the aliquots of whole blood into their respective compartments, where they are separated into cellular and plasma fractions. As the rotor speed is slowly decreased, an aliquot of plasma is withdrawn by capillary action into each measuring capillary. The disk containing the 16 measured aliquots of plasma is then removed and placed into a modified rotor for conventional centrifugal analysis. This device can entrain and deliver microliter volumes of liquids with precision and accuracy (1-2%) near that of mechanical pipettes. Assays of the separated plasma aliquots also have acceptable precision (e.g., CVs approximately 3% for measurements of serum enzymes).

  4. Plasma metallization

    CERN Document Server

    Crowther, J M

    1997-01-01

    Many methods are currently used for the production of thin metal films. However, all of these have drawbacks associated with them, for example the need for UHV conditions, high temperatures, exotic metal precursors, or the inability to coat complex shaped objects. Reduction of supported metal salts by non-isothermal plasma treatment does not suffer from these drawbacks. In order to produce and analyse metal films before they become contaminated, a plasma chamber which could be attached directly to a UHV chamber with XPS capability was designed and built. This allowed plasma treatment of supported metal salts and surface analysis by XPS to be performed without exposure of the metal film to the atmosphere. Non-equilibrium plasma treatment of Nylon 66 supported gold(lll) chloride using hydrogen as the feed gas resulted in a 95% pure gold film, the remaining 5% of the film being carbon. If argon or helium were used as the feed gases during plasma treatment the resultant gold films were 100% pure. Some degree of s...

  5. Analysis of inflammatory response in human plasma samples by an automated multicapillary electrophoresis system.

    Science.gov (United States)

    Larsson, Anders; Hansson, Lars-Olof

    2004-01-01

    A new automated multicapillary zone electrophoresis instrument with a new high-resolution (HR) buffer (Capillarys with HR buffer) for analysis of human plasma proteins was evaluated. Albumin, alpha(1)-antitrypsin, alpha(1)-acid glycoprotein, haptoglobin, fibrinogen, immunoglobulin (Ig)A, IgG and IgM were determined nephelometrically in 200 patient plasma samples. The same samples were then analyzed on the Capillarys system (Sebia, Paris, France). The albumin concentration from the nephelometric determination was used for quantification of the individual peaks in the capillary electrophoresis (CE) electropherogram. There was strong linear correlation between the nephelometric and electrophoretic determination of alpha(1)-antitrypsin (R(2) = 0.906), alpha(1)-acid glycoprotein (R(2) =0.894) and haptoglobin (R(2) = 0.913). There was also good correlation between the two determinations of gamma-globulins (R(2) = 0.883), while the correlation was weaker for fibrinogen (R(2) = 0.377). The Capillarys instrument is a reliable system for plasma protein analysis, combining the advantages of full automation, good analytical performance and high throughput. The HR buffer in combination with albumin quantification allows the simultaneous quantification of inflammatory markers in plasma samples without the need for nephelometric determination of these proteins.

  6. Plasma dynamo

    CERN Document Server

    Rincon, F; Schekochihin, A A; Valentini, F

    2015-01-01

    Magnetic fields pervade the entire Universe and, through their dynamical interactions with matter, affect the formation and evolution of astrophysical systems from cosmological to planetary scales. How primordial cosmological seed fields arose and were further amplified to $\\mu$Gauss levels reported in nearby galaxy clusters, near equipartition with kinetic energy of plasma motions and on scales of at least tens of kiloparsecs, is a major theoretical puzzle still largely unconstrained by observations. Extragalactic plasmas are weakly collisional (as opposed to collisional magnetohydrodynamic fluids), and whether magnetic-field growth and its sustainment through an efficient dynamo instability driven by chaotic motions is possible in such plasmas is not known. Fully kinetic numerical simulations of the Vlasov equation in a six-dimensional phase space necessary to answer this question have until recently remained beyond computational capabilities. Here, we show by means of such simulations that magnetic-field a...

  7. Plasma medicine

    CERN Document Server

    Fridman, Alexander

    2012-01-01

    This comprehensive text is suitable for researchers and graduate students of a 'hot' new topic in medical physics. Written by the world's leading experts,  this book aims to present recent developments in plasma medicine, both technological and scientific, reviewed in a fashion accessible to the highly interdisciplinary audience consisting of doctors, physicists, biologists, chemists and other scientists, university students and professors, engineers and medical practitioners. The book focuses on major topics and covers the physics required to develop novel plasma discharges relevant for medic

  8. Design and Demonstration of a Material-Plasma Exposure Target Station for Neutron Irradiated Samples

    Energy Technology Data Exchange (ETDEWEB)

    Rapp, Juergen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Aaron, A. M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bell, Gary L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Burgess, Thomas W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ellis, Ronald James [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Giuliano, D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Howard, R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kiggans, James O. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Lessard, Timothy L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ohriner, Evan Keith [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Perkins, Dale E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Varma, Venugopal Koikal [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-10-20

    -state heat fluxes of 5–20 MW/m2 and ion fluxes up to 1024 m-2s-1. Since PFCs will have to withstand neutron irradiation displacement damage up to 50 dpa, the target station design must accommodate radioactive specimens (materials to be irradiated in HFIR or at SNS) to enable investigations of the impact of neutron damage on materials. Therefore, the system will have to be able to install and extract irradiated specimens using equipment and methods to avoid sample modification, control contamination, and minimize worker dose. Included in the design considerations will be an assessment of all the steps between neutron irradiation and post-exposure materials examination/characterization, as well as an evaluation of the facility hazard categorization. In particular, the factors associated with the acquisition of radioactive specimens and their preparation, transportation, experimental configuration at the plasma-specimen interface, post-plasma-exposure sample handling, and specimen preparation will be evaluated. Neutronics calculations to determine the dose rates of the samples were carried out for a large number of potential plasma-facing materials.

  9. Plasma physics and engineering

    CERN Document Server

    Fridman, Alexander

    2011-01-01

    Part I: Fundamentals of Plasma Physics and Plasma ChemistryPlasma in Nature, in the Laboratory, and in IndustryOccurrence of Plasma: Natural and Man MadeGas DischargesPlasma Applications, Plasmas in IndustryPlasma Applications for Environmental ControlPlasma Applications in Energy ConversionPlasma Application for Material ProcessingBreakthrough Plasma Applications in Modern TechnologyElementary Processes of Charged Species in PlasmaElementary Charged Particles in Plasma and Their Elastic and Inelastic CollisionsIonization ProcessesMechanisms of Electron Losses: The Electron-Ion RecombinationEl

  10. Overestimation of canine albumin concentration with the bromcresol green method in heparinized plasma samples.

    Science.gov (United States)

    Stokol, Tracy; Tarrant, Jacqueline M.; Scarlett, Janet M.

    2001-01-01

    Albumin concentrations are routinely measured in dogs with bromcresol green (BCG)-binding assays on automated chemistry analyzers. Several variables affect this assay, including the length of reaction time, sample type, and lack of specificity of BCG for albumin. We observed that albumin concentrations measured with BCG appeared higher in heparinized plasma samples in sick dogs. The objective of this study was to determine the effect of anticoagulant and assay procedure on BCG albumin concentrations in clinically ill dogs. We hypothesized that albumin concentrations would be overestimated in heparinized plasma compared with serum because of the combination of heparin and fibrinogen. Furthermore, we hypothesized that the overestimation would be influenced by assay parameters. Blood was collected from 32 clinically ill dogs into tubes containing heparin, citrate, or no anticoagulant. Citrate was chosen to assess the effect of fibrinogen in the absence of heparin. Albumin concentration was measured in all 3 sample types from each dog using 2 different BCG procedures on an automated chemistry analyzer. The BCG procedures (standard and modified) differed in the wavelengths used for absorbance readings (standard, 600/700; modified, 570/505) and the time point at which absorbance was measured (standard, 100 seconds; modified, 40 seconds). In addition, the modified method incorporated a sample blank. Globulin fractions, fibrinogen concentration, and indices of lipemia, hemolysis, and icterus were evaluated for their contribution to the overestimation of albumin concentration in heparinized plasma compared with serum samples. Albumin concentrations were significantly higher (P plasma (mean +/- SE, 3.8 +/- 0.1 g/dL) than in serum (3.6 +/- 0.2 g/dL) or citrated plasma (3.2 +/- 0.1 g/dL). Overestimation was evident only with the standard BCG procedure. Multiple linear regression analysis indicated that fibrinogen was largely responsible for the higher

  11. Determination of quinolones in plasma samples by capillary electrophoresis using solid-phase extraction.

    Science.gov (United States)

    Hernández, M; Borrull, F; Calull, M

    2000-06-09

    The potential of capillary zone electrophoresis (CZE) and micellar electrokinetic capillary chromatography (MEKC) have been investigated for the separation and quantitative determination of 10 quinolone antibiotics. The influence of different conditions, such as the buffer and pH of the electrolyte, the surfactant and the ion-pairing agents added to the electrolyte and the organic modifier were studied. A buffer consisting of 40 mM sodium tetraborate at pH 8.1 containing 10% (v/v) methanol was found to be a highly efficient electrophoretic system for separating lomefloxacin, enoxacin, norfloxacin, pipemidic acid, ofloxacin, piromidic acid, flumequine, oxolinic acid, cinoxacin and nalidixic acid. A solid-phase extraction method to remove the sample matrix (pig plasma samples) was developed on a C(18) cartridge using a mixture of methanol-water (70:30, v/v). The method is specific and reproducible and mean recoveries were in the range 94.0+/-4.2% and 123.3+/-4.1% for pig plasma samples over the range used. A linear relationship between concentration and peak area for each compound in pig plasma samples was obtained in the concentration range 5-20 mg l(-1) and detection limits were between 1.1 and 2.4 mg l(-1).

  12. Design and Demonstration of a Material-Plasma Exposure Target Station for Neutron Irradiated Samples

    Energy Technology Data Exchange (ETDEWEB)

    Rapp, Juergen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Aaron, A. M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bell, Gary L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Burgess, Thomas W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ellis, Ronald James [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Giuliano, D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Howard, R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kiggans, James O. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Lessard, Timothy L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ohriner, Evan Keith [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Perkins, Dale E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Varma, Venugopal Koikal [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-10-20

    -state heat fluxes of 5–20 MW/m2 and ion fluxes up to 1024 m-2s-1. Since PFCs will have to withstand neutron irradiation displacement damage up to 50 dpa, the target station design must accommodate radioactive specimens (materials to be irradiated in HFIR or at SNS) to enable investigations of the impact of neutron damage on materials. Therefore, the system will have to be able to install and extract irradiated specimens using equipment and methods to avoid sample modification, control contamination, and minimize worker dose. Included in the design considerations will be an assessment of all the steps between neutron irradiation and post-exposure materials examination/characterization, as well as an evaluation of the facility hazard categorization. In particular, the factors associated with the acquisition of radioactive specimens and their preparation, transportation, experimental configuration at the plasma-specimen interface, post-plasma-exposure sample handling, and specimen preparation will be evaluated.

  13. Analysis of surface chemistry of boronized TZM samples in NSTX-U between plasma exposures

    Science.gov (United States)

    Schamis, Hanna; Bedoya, Felipe; Allain, Jean Paul; Kaita, Robert; Koel, Bruce

    2016-10-01

    In the National Spherical Torus Experiment Upgrade (NSTX-U) a new plasma facing component diagnostic, the Material Analysis and Particle Probe (MAPP), was installed. MAPP has the capability of conducting XPS studies on materials without exposing them to atmospheric conditions. MAPP was used to conduct XPS studies of TZM (99% Mo, 0.5% Ti, 0.08% Zr) samples. XPS gives information about the chemical composition of up to about 5 nm of the surface, and can be conducted on a day-to-day basis or at higher temporal resolutions e.g. close to in-between plasma shots. MAPP characterization gives insight on boron deposition and fuel retention by following the evolution of atomic concentrations and oxidation states. The data shows that the boron deposited layer was thicker than 5 nm. Additionally, the data shows evidence of sputtering of the boron layers following tens of plasma shots. The data also shows an increase in the oxygen concentration with plasma exposure. The next NSTX-U experimental campaign will feature TZM tiles in the lower divertor region, while the rest of the first wall will continue to be ATJ graphite. Our data provides the basis to analyze how the surface chemistry of the new set of tiles will be influenced by plasma operations, boron conditioning and carbon migration. Work supported by US DOE Contract No. DE-AC02-09CH11466, US DOE Contract No. DE-SC0010717, Award No. DE-SC0012890, and the DOE Science Undergraduate Laboratory Internship (SULI) Program.

  14. Magnetoresistive waves in plasmas

    Science.gov (United States)

    Felber, F. S.; Hunter, R. O., Jr.; Pereira, N. R.; Tajima, T.

    1982-10-01

    The self-generated magnetic field of a current diffusing into a plasma between conductors can magnetically insulate the plasma. Propagation of magnetoresistive waves in plasmas is analyzed. Applications to plasma opening switches are discussed.

  15. Etching of Niobium Sample Placed on Superconducting Radio Frequency Cavity Surface in Ar/CL2 Plasma

    Energy Technology Data Exchange (ETDEWEB)

    Janardan Upadhyay, Larry Phillips, Anne-Marie Valente

    2011-09-01

    Plasma based surface modification is a promising alternative to wet etching of superconducting radio frequency (SRF) cavities. It has been proven with flat samples that the bulk Niobium (Nb) removal rate and the surface roughness after the plasma etchings are equal to or better than wet etching processes. To optimize the plasma parameters, we are using a single cell cavity with 20 sample holders symmetrically distributed over the cell. These holders serve the purpose of diagnostic ports for the measurement of the plasma parameters and for the holding of the Nb sample to be etched. The plasma properties at RF (100 MHz) and MW (2.45 GHz) frequencies are being measured with the help of electrical and optical probes at different pressures and RF power levels inside of this cavity. The niobium coupons placed on several holders around the cell are being etched simultaneously. The etching results will be presented at this conference.

  16. Quantitative analysis of Tenecteplase in rat plasma samples using LC-MS/MS as an alternative for ELISA

    NARCIS (Netherlands)

    Buscher, B.A.P.; Gerritsen, H.; Schöll, I. van; Cnubben, N.H.P.; Brüll, L.P.

    2007-01-01

    An LC-MS/MS method has been developed for the quantitative determination of a protein drug (Tenecteplase; MW 58,777 Da) in rat plasma. The protein was digested with trypsin without prior clean-up of the plasma sample, without the use of a label nor internal standard. A limited validation was perform

  17. Quantitative analysis of Tenecteplase in rat plasma samples using LC-MS/MS as an alternative for ELISA

    NARCIS (Netherlands)

    Buscher, B.A.P.; Gerritsen, H.; Schöll, I. van; Cnubben, N.H.P.; Brüll, L.P.

    2007-01-01

    An LC-MS/MS method has been developed for the quantitative determination of a protein drug (Tenecteplase; MW 58,777 Da) in rat plasma. The protein was digested with trypsin without prior clean-up of the plasma sample, without the use of a label nor internal standard. A limited validation was perform

  18. Electrosurgical plasmas

    Science.gov (United States)

    Stalder, Kenneth R.; McMillen, Donald F.; Woloszko, Jean

    2005-06-01

    Electrosurgical medical devices based on repetitively pulsed nonequilibrium micron-scale to millimetre-scale plasma discharges in saline solutions are described. The formation of vapour layers (bubbles) around active electrodes appears to be a common feature at moderate (<300 V rms) voltages, and dissociation, excitation and ionization of the vapour in these bubbles produces chemical conditions that are thought to be the source of beneficial tissue removal and treatment. Experimental data are discussed, as are the results of modelling efforts of the plasma chemistry. Hydroxyl radicals, hydrogen atoms and other species are observed spectroscopically and their interactions with collagen, a common component of tissue encountered in surgical situations, are considered. Several pathways by which hydroxyl radicals interacting with collagen can lead to tissue removal are discussed.

  19. Electrosurgical plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Stalder, Kenneth R; McMillen, Donald F; Woloszko, Jean [ArthroCare Corp., Sunnyvale, CA 94085-3523 (United States)

    2005-06-07

    Electrosurgical medical devices based on repetitively pulsed nonequilibrium micron-scale to millimetre-scale plasma discharges in saline solutions are described. The formation of vapour layers (bubbles) around active electrodes appears to be a common feature at moderate (<300 V rms) voltages, and dissociation, excitation and ionization of the vapour in these bubbles produces chemical conditions that are thought to be the source of beneficial tissue removal and treatment. Experimental data are discussed, as are the results of modelling efforts of the plasma chemistry. Hydroxyl radicals, hydrogen atoms and other species are observed spectroscopically and their interactions with collagen, a common component of tissue encountered in surgical situations, are considered. Several pathways by which hydroxyl radicals interacting with collagen can lead to tissue removal are discussed.

  20. Ultracold neutral plasmas

    Science.gov (United States)

    Lyon, M.; Rolston, S. L.

    2017-01-01

    By photoionizing samples of laser-cooled atoms with laser light tuned just above the ionization limit, plasmas can be created with electron and ion temperatures below 10 K. These ultracold neutral plasmas have extended the temperature bounds of plasma physics by two orders of magnitude. Table-top experiments, using many of the tools from atomic physics, allow for the study of plasma phenomena in this new regime with independent control over the density and temperature of the plasma through the excitation process. Characteristic of these systems is an inhomogeneous density profile, inherited from the density distribution of the laser-cooled neutral atom sample. Most work has dealt with unconfined plasmas in vacuum, which expand outward at velocities of order 100 m/s, governed by electron pressure, and with lifetimes of order 100 μs, limited by stray electric fields. Using detection of charged particles and optical detection techniques, a wide variety of properties and phenomena have been observed, including expansion dynamics, collective excitations in both the electrons and ions, and collisional properties. Through three-body recombination collisions, the plasmas rapidly form Rydberg atoms, and clouds of cold Rydberg atoms have been observed to spontaneously avalanche ionize to form plasmas. Of particular interest is the possibility of the formation of strongly coupled plasmas, where Coulomb forces dominate thermal motion and correlations become important. The strongest impediment to strong coupling is disorder-induced heating, a process in which Coulomb energy from an initially disordered sample is converted into thermal energy. This restricts electrons to a weakly coupled regime and leaves the ions barely within the strongly coupled regime. This review will give an overview of the field of ultracold neutral plasmas, from its inception in 1999 to current work, including efforts to increase strong coupling and effects on plasma properties due to strong coupling.

  1. Plasma physics

    CERN Document Server

    Cairns, R A

    1985-01-01

    This book is intended as an introduction to plasma physics at a level suitable for advanced undergraduates or beginning postgraduate students in physics, applied mathematics or astrophysics. The main prerequisite is a knowledge of electromagnetism and of the associated mathematics of vector calculus. SI units are used throughout. There is still a tendency amongst some plasma physics researchers to· cling to C.g.S. units, but it is the author's view that universal adoption of SI units, which have been the internationally agreed standard since 1960, is to be encouraged. After a short introductory chapter, the basic properties of a plasma con­ cerning particle orbits, fluid theory, Coulomb collisions and waves are set out in Chapters 2-5, with illustrations drawn from problems in nuclear fusion research and space physics. The emphasis is on the essential physics involved and (he theoretical and mathematical approach has been kept as simple and intuitive as possible. An attempt has been made to draw attention t...

  2. Chimeric External Control to Quantify Cell Free DNA in Plasma Samples by Real Time PCR

    Science.gov (United States)

    Eini, Maryam; Behzad-Behbahani, Abbas; Takhshid, Mohammad Ali; Ramezani, Amin; Rafiei Dehbidi, Gholam Reza; Okhovat, Mohammad Ali; Farhadi, Ali; Alavi, Parniyan

    2016-01-01

    Background: DNA isolation procedure can significantly influence the quantification of DNA by real time PCR specially when cell free DNA (cfDNA) is the subject. To assess the extraction efficiency, linearity of the extraction yield, presence of co-purified inhibitors and to avoid problems with fragment size relevant to cfDNA, development of appropriate External DNA Control (EDC) is challenging. Using non-human chimeric nucleotide sequences, an EDC was developed for standardization of qPCR for monitoring stability of cfDNA concentration in blood samples over time. Methods: A0 DNA fragment of 167 bp chimeric sequence of parvovirus B19 and pBHA designated as EDC fragment was designed. To determine the impact of different factors during DNA extraction processing on quantification of cfDNA, blood samples were collected from normal subjects and divided into aliquots with and without specific treatment. In time intervals, the plasma samples were isolated. The amplicon of 167 bp EDC fragment in final concentration of 1.1 pg/500 μl was added to each plasma sample and total DNA was extracted by an in house method. Relative and absolute quantification real time PCR was performed to quantify both EDC fragment and cfDNA in extracted samples. Results: Comparison of real time PCR threshold cycle (Ct) for cfDNA fragment in tubes with and without specific treatment indicated a decrease in untreated tubes. In contrast, the threshold cycle was constant for EDC fragment in treated and untreated tubes, indicating the difference in Ct values of the cfDNA is because of specific treatments that were made on them. Conclusions: Spiking of DNA fragment size relevant to cfDNA into the plasma sample can be useful to minimize the bias due to sample preparation and extraction processing. Therefore, it is highly recommended that standard external DNA control be employed for the extraction and quantification of cfDNA for accurate data analysis. PMID:27141267

  3. Plasma pharmacy - physical plasma in pharmaceutical applications.

    Science.gov (United States)

    von Woedtke, Th; Haertel, B; Weltmann, K-D; Lindequist, U

    2013-07-01

    During the last years the use of physical plasma for medical applications has grown rapidly. A multitude of findings about plasma-cell and plasma-tissue interactions and its possible use in therapy have been provided. One of the key findings of plasma medical basic research is that several biological effects do not result from direct plasma-cell or plasma-tissue interaction but are mediated by liquids. Above all, it was demonstrated that simple liquids like water or physiological saline, are antimicrobially active after treatment by atmospheric pressure plasma and that these effects are attributable to the generation of different low-molecular reactive species. Besides, it could be shown that plasma treatment leads to the stimulation of specific aspects of cell metabolism and to a transient and reversible increase of diffusion properties of biological barriers. All these results gave rise to think about another new and innovative field of medical plasma application. In contrast to plasma medicine, which means the direct use of plasmas on or in the living organism for direct therapeutic purposes, this field - as a specific field of medical plasma application - is called plasma pharmacy. Based on the present state of knowledge, most promising application fields of plasma pharmacy might be: plasma-based generation of biologically active liquids; plasma-based preparation, optimization, or stabilization of - mainly liquid - pharmaceutical preparations; support of drug transport across biological barriers; plasma-based stimulation of biotechnological processes.

  4. Elevated phospholipase A2 activities in plasma samples from multiple cancers.

    Directory of Open Access Journals (Sweden)

    Hui Cai

    Full Text Available Only in recent years have phospholipase A2 enzymes (PLA2s emerged as cancer targets. In this work, we report the first detection of elevated PLA2 activities in plasma from patients with colorectal, lung, pancreatic, and bladder cancers as compared to healthy controls. Independent sets of clinical plasma samples were obtained from two different sites. The first set was from patients with colorectal cancer (CRC; n = 38 and healthy controls (n = 77. The second set was from patients with lung (n = 95, bladder (n = 31, or pancreatic cancers (n = 38, and healthy controls (n = 79. PLA2 activities were analyzed by a validated quantitative fluorescent assay method and subtype PLA2 activities were defined in the presence of selective inhibitors. The natural PLA2 activity, as well as each subtype of PLA2 activity was elevated in each cancer group as compared to healthy controls. PLA2 activities were increased in late stage vs. early stage cases in CRC. PLA2 activities were not influenced by sex, smoking, alcohol consumption, or body-mass index (BMI. Samples from the two independent sites confirmed the results. Plasma PLA2 activities had approximately 70% specificity and sensitivity to detect cancer. The marker and targeting values of PLA2 activity have been suggested.

  5. Determination of trovafloxacin and marbofloxacin in sheep plasma samples by HPLC using UV detection.

    Science.gov (United States)

    Mahmood, Adnan H; Medley, Gregory A; Grice, Jeffrey E; Liu, Xin; Roberts, Michael S

    2012-03-25

    A simple and rapid high performance liquid chromatographic method was developed, validated and applied for the simultaneous determination of marbofloxacin (MBX) and trovafloxacin (TVX) in sheep plasma. Samples were extracted with 20% perchloric acid and MBX and TVX were separated on a C(18) column using a gradient mobile phase system consisting of 17.5mM of NaH(2)PO(4) and 1.5mM of tetrabutylammonium hydroxide aqueous solution, pH 3 (A) and 50% acetonitrile and 50% methanol (B), with UV detection at 293 and 270 nm. The retention times of MBX and TVX were 4.9 and 6.6 min respectively. The detection and quantification limits for MBX and TVX were 2 ng/mL and 10 ng/mL respectively for both compounds. The calibration curves were linear over a concentration range of 10-50,000 ng/mL for both antibiotics. The linearity, precision, accuracy, recovery and stability of the assay were evaluated from spiked sheep plasma. The method was successfully applied to sheep plasma samples obtained from MBX and TVX pharmacokinetic studies.

  6. Development of a chromatographic method for the determination of saquinavir in plasma samples of HIV patients.

    Science.gov (United States)

    Campanero, M A; Escolar, M; Arangoa, M A; Sádaba, B; Azanza, J R

    2002-02-01

    A simple, sensitive and reproducible high-performance liquid chromatographic method for detecting and quantifying saquinavir in human plasma is described. Verapamil was used as internal standard. The method employes a single liquid-liquid extraction step with tert-butil methyl ether followed by chromatography on a Lichrospher 60 Select B C8 reversed-phase column. Ultraviolet detection was used to identify the compounds of interest. The quantitation limit of saquinavir was 1 ng/mL and only 0.5 mL of plasma sample was required for the determination. The average saquinavir recoveries over a concentration range of 2.5-500 ng/mL ranged from 86 to 95%. Precision and accuracy did not exceed 5%.

  7. An evaluation of multiplex bead-based analysis of cytokines and soluble proteins in archived lithium heparin plasma, EDTA plasma and serum samples

    DEFF Research Database (Denmark)

    Brøndum, Line; Sørensen, Brita Singers; Eriksen, Jesper Grau

    2016-01-01

    in plasma and serum from 86 head and neck cancer patients and 33 controls were evaluated: EGFR, leptin, OPN, VEGFR-1, VEGFR-2, IL-2, IL-13, PDGF-bb, TNF, PAI-1, SDF-1a, IL-4, IL-6, IL-8, eotaxin, G-CSF, VEGF, GRO-a, and HGF. RESULTS: The correlation between measurements of the same samples analyzed...

  8. An attempt to validate serum and plasma as sample matrices for analyses of polychlorobiphenylols

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, J.; Bergman, Aa. [Stockholm Univ. (Sweden). Dept. of Environmental Chemistry; Bignert, A. [Museum of Natural History (Sweden)

    2004-09-15

    Polychlorinated biphenyls (PCBs) form hydroxylated metabolites (OH-PCBs), as reported both from wildlife and from experimental animal studies already in the early 1970s'. However, the interest increased in OH-PCBs from the mid 1990s' depending on the discovery that some OHPCB congeners are strongly retained in the blood of birds, fish and mammals, including humans. The interest is linked to the fact that OH-PCBs is strongly, but reversibly, bound to the blood protein transthyretin (TTR). It is reasonable to believe that the strong TTR binding may have toxicological impact, probably related to endocrine type effects. Importantly, OH-PCBs are present in blood at far higher concentrations than in any other compartment in the body, which is dependent on the physico-chemical characteristics of the phenols. Analyses of OH-PCBs have thus been concentrated to whole blood, plasma or serum. Still there is no comparison between the three sample types even though it is clear that whole blood is not optimal due to the large proportion of haemoglobin in the sample that make the clean up more difficult than if plasma or serum is selected for analysis. In the present study we have addressed two questions: First we have looked at any potential differences in the analytical results of OH-PCBs when using serum and plasma for extraction and clean up; Second, the serum and plasma applied in the validation has been unfrozen, frozen (at -20 C) for two months and frozen for twenty months, respectively.

  9. Observation of asymmetrically imploded core plasmas with a two-dimensional sampling image x-ray streak camera.

    Science.gov (United States)

    Shiraga, Hiroyuki; Lee, Myongdok; Mahigashi, Norimitsu; Fujioka, Shinsuke; Azechi, Hiroshi

    2008-10-01

    A shell target with a cone for guiding the heating beam has been proposed for the fast ignition scheme. Implosion of such target is no longer symmetric because of the cone. A fast two-dimensional x-ray imaging technique, two-dimensional (2D) sampling image x-ray streak camera was applied for the first time to observation of the dynamics of implosion and core plasma. X-ray emission image of the plasma was sampled with two-dimensionally distributed image sampling points, streaked with the tube, and the recorded signals were reconstructed as sequential 2D frame images. Shape and movement of the core plasma were clearly observed.

  10. A simple sample preparation method for measuring amoxicillin in human plasma by hollow fiber centrifugal ultrafiltration.

    Science.gov (United States)

    Dong, Wei-Chong; Hou, Zi-Li; Jiang, Xin-Hui; Jiang, Ye

    2013-02-01

    A simple sample preparation method has been developed for the determination of amoxicillin in human plasma by hollow fiber centrifugal ultrafiltration (HF-CF-UF). A 400-μL plasma sample was placed directly into the HF-CF-UF device, which consisited of a slim glass tube and a U-shaped hollow fiber. After centrifugation at 1.25 × 10(3) g for 10 min, the filtrate was withdrawn from the hollow fiber and 20 µL was directly injected into the high-performance liquid chromatography (HPLC) for analysis. The calibration curve was linear over the range of 0.1-20 µg/mL (r = 0.9996) and the limit of detection was as low as 0.025 µg/mL. The average recovery and absolute recovery were 99.9% and 84.5%, respectively. Both the intra-day and inter-day precisions (relative standard deviation) were less than 3.1% for three concentrations (0.25, 2.5 and 10 µg/mL). The sample preparation process was simplified. Only after a single centrifugal ultrafiltration can the filtrate be injected directly into HPLC. The present method is simple, sensitive and accurate. It could be effective for the analysis of biological samples with high protein contents, especially for the biopharmaceutical analysis of drugs that use traditional isolation techniques for sample preparation such as the protein precipitation method.

  11. Analysis of iodine in food samples by inductively coupled plasma-mass spectrometry.

    Science.gov (United States)

    Todorov, Todor I; Gray, Patrick J

    2016-01-01

    This work shows a method for the determination of iodine in a variety of food samples and reference materials using inductively coupled plasma-mass spectrometry (ICP-MS) following alkaline extraction. Optimisation of the addition of organic carbon showed that a minimum of 3% 2-propanol was necessary for a constant ratio of iodine to internal standard. The limit of quantification (LOQ), calculated as 30σ for the method, was 36 ng g(-1) in solid food samples. For method validation, seven standard reference materials (SRM) and 21 fortified food samples were used. The precision (%RSD) of the measurements was in the 2-7% range. Accuracies for the SRMs were 85-105%, while the fortified food samples showed 81-119% recoveries, including a number of samples fortified at 50% of the LOQ.

  12. Long-term performance and stability of molecular shotgun lipidomic analysis of human plasma samples.

    Science.gov (United States)

    Heiskanen, Laura A; Suoniemi, Matti; Ta, Hung Xuan; Tarasov, Kirill; Ekroos, Kim

    2013-09-17

    The stability of the lipid concentration levels in shotgun lipidomics analysis was tracked over a period of 3.5 years. Concentration levels in several lipid classes, such as phospholipids, were determined in human plasma lipid extracts. Impact of the following factors on the analysis was investigated: sample amount, internal standard amount, and sample dilution factor. Moreover, the reproducibility of lipid profiles obtained in both polarity modes was evaluated. Total number of samples analyzed was approximately 6800 and 7300 samples in negative and positive ion modes, respectively, out of which 610 and 639 instrument control samples were used in stability calculations. The assessed shotgun lipidomics approach showed to be remarkably robust and reproducible, requiring no batch corrections. Coefficients of variation (CVs) of lipid mean concentration measured with optimized analytical parameters were typically less than 15%. The high reproducibility indicated that no lipid degradation occurred during the monitored time period.

  13. Quantitative analysis of Tenecteplase in rat plasma samples using LC-MS/MS as an alternative for ELISA.

    Science.gov (United States)

    Buscher, B A P; Gerritsen, H; van Schöll, I; Cnubben, N H P; Brüll, L P

    2007-06-01

    An LC-MS/MS method has been developed for the quantitative determination of a protein drug (Tenecteplase; M(W) 58,777 Da) in rat plasma. The protein was digested with trypsin without prior clean-up of the plasma sample, without the use of a label nor internal standard. A limited validation was performed to assess the linearity, the sensitivity and the specificity of the method. In addition, the developed method was applied to the quantitative analysis of Tenecteplase in rat plasma samples originating from a single-dose study in rats.

  14. Catecholamines in plasma from artery, cubital vein, and femoral vein in patients with cirrhosis. Significance of sampling site

    DEFF Research Database (Denmark)

    Henriksen, J H; Ring-Larsen, H; Christensen, N J

    1986-01-01

    The concentration of noradrenaline (NA) and adrenaline (A) was measured in arterial, cubital venous and femoral venous plasma in order to determine possible differences in different vascular beds in the peripheral circulation. In patients with cirrhosis, arterial plasma NA (median 2.54 nmol/l, n ...... the skin of forearm and hand). To assess circulating levels of catecholamines, the importance of arterial sampling is stressed as peripheral venous samples may also reflect local factors....

  15. Multi-elemental analysis of aqueous geological samples by inductively coupled plasma-optical emission spectrometry

    Science.gov (United States)

    Todorov, Todor I.; Wolf, Ruth E.; Adams, Monique

    2014-01-01

    Typically, 27 major, minor, and trace elements are determined in natural waters, acid mine drainage, extraction fluids, and leachates of geological and environmental samples by inductively coupled plasma-optical emission spectrometry (ICP-OES). At the discretion of the analyst, additional elements may be determined after suitable method modifications and performance data are established. Samples are preserved in 1–2 percent nitric acid (HNO3) at sample collection or as soon as possible after collection. The aqueous samples are aspirated into the ICP-OES discharge, where the elemental emission signals are measured simultaneously for 27 elements. Calibration is performed with a series of matrix-matched, multi-element solution standards.

  16. Automated processing of whole blood samples into microliter aliquots of plasma

    OpenAIRE

    1988-01-01

    A rotor that accepts and automatically processes a bulk aliquot of a single blood sample into multiple aliquots of plasma has been designed and built. The rotor consists of a central processing unit, which includes a disk containing eight precision-bore capillaries. By varying the internal diameters of the capillaries, aliquot volumes ranging 1 to 10 μl can be prepared. In practice, an unmeasured volume of blood is placed in a centre well, and, as the rotor begins to spin, is moved radially i...

  17. EDITORIAL: Plasma jets and plasma bullets Plasma jets and plasma bullets

    Science.gov (United States)

    Kong, M. G.; Ganguly, B. N.; Hicks, R. F.

    2012-06-01

    technological solution in the early to late 1990s of confining atmospheric plasmas in a small volume of plasma generation (i.e. with a small volume-to-surface ratio) and then extending it towards a downstream sample [7]-[9]. These are among the first low-temperature atmospheric plasmas aimed particularly at the exploitation of their ability to invoke the active and rich reactive chemistry close to ambient temperature. The main applications of these early devices are precision surface modification of low-temperature dielectric materials, for example thin film deposition and etching [7]-[9]. Variations of the early plasma jets include atmospheric plasma sheet jets [10] for the treatment of largely planar objects (e.g. polymeric sheets) as well as large arrays of many plasma jets for the treatment of complex-structured objects (e.g. surgical tools and open human wounds) [11]. As a material processing technology, the sub-100oC atmospheric-pressure plasma jet has benefited over the years from many innovations. Whilst a detailed account and analysis of these is clearly outside the scope of this Editorial, it is worth stating that there are different avenues with which to maintain a moderate electron density at the plasma core so as to keep the gas temperature at the sample point below a ceiling level. Most of the early studies employed excitation at radio frequencies above 10 MHz, at which electrons are largely confined in the plasma generation region, and this limits the current flow to and gas heating in the plume region of the plasma jet. Other techniques of current limitation have since been shown to be effective, including the use of dielectric barriers across a very large frequency range of 1 kHz--50 MHz, sub-microsecond pulses sustained at kHz frequencies, pulse-modulated radio frequencies and dual-frequency excitation [12]-[15]. These and other techniques have considerably advanced the atmospheric-pressure plasma jet technology. The period of some 15 years since the above

  18. Determination of the neutral oxygen atom density in a plasma reactor loaded with metal samples

    Energy Technology Data Exchange (ETDEWEB)

    Mozetic, Miran; Cvelbar, Uros [Jozef Stefan Institute, Jamova cesta 39, 1000 Ljubljana (Slovenia)], E-mail: miran.mozetic@ijs.si

    2009-08-15

    The density of neutral oxygen atoms was determined during processing of metal samples in a plasma reactor. The reactor was a Pyrex tube with an inner diameter of 11 cm and a length of 30 cm. Plasma was created by an inductively coupled radiofrequency generator operating at a frequency of 27.12 MHz and output power up to 500 W. The O density was measured at the edge of the glass tube with a copper fiber optics catalytic probe. The O atom density in the empty tube depended on pressure and was between 4 and 7 x 10{sup 21} m{sup -3}. The maximum O density was at a pressure of about 150 Pa, while the dissociation fraction of O{sub 2} molecules was maximal at the lowest pressure and decreased with increasing pressure. At about 300 Pa it dropped below 10%. The measurements were repeated in the chamber loaded with different metallic samples. In these cases, the density of oxygen atoms was lower than that in the empty chamber. The results were explained by a drain of O atoms caused by heterogeneous recombination on the samples.

  19. Determination by high-performance liquid chromatography of phenylbutazone in samples of plasma from fighting bulls.

    Science.gov (United States)

    Marti, M I González; Sánchez, González C I; Jiménez, Hernández; Cachán, García; Castro, de Cabo M J; Cuadrado, A L Garzón

    2002-03-25

    The purpose of this study was to investigate the possible presence of phenylbutazone in plasma samples from fighting bulls killed in 2nd and 3rd category bullrings in the province of Salamanca (Spain) in 1998, 1999 and 2000. For quantitative and qualitative determination, a high-performance liquid chromatograph was used, equipped with a photodiode-array detector and setting wavelengths at 240, 254 and 284 nm. The mobile phase optimized for the simultaneous detection of dexamethasone, betamethasone, flunixin and phenylbutazone, was 0.01 M acetic acid pH 3 in methanol (35:65 v/v) at a flow rate of 1 ml/min. Plasma samples were deproteinized with 400 microl of acetonitrile and 20 microl of the supernatant were injected directly into the chromatographic system equipped with a Lichrospher 60 RP select B column and guard column. For the quantitative analysis, standard calibration curves were made in a concentration range between 0.25 and 30 microg/ml, using betamethasone as internal standard. The retention time of phenylbutazone was 8.7 +/- 0.2 min and recovery was 83%. The detection and quantification limits were 0.016 and 0.029, respectively for A=240 nm. The study results show that 17 of the 74 samples analyzed in 1998, 18 of those from 1999 and 10 of those from 2000 were positive for phenylbutazone.

  20. Studies of lithium deposition and D retention on tungsten samples exposed to Li-seeded plasmas in PISCES-A

    Science.gov (United States)

    Tabarés, F. L.; Alegre, D.; Baldwin, M.; Nishijima, D.; Simmonds, M.; Doerner, R.; Alves, E.; Mateus, R.

    2017-04-01

    The interaction between lithium-seeded deuterium plasmas and tungsten targets has been studied in the PISCES-A divertor plasma simulator. Tungsten samples, of ITER-grade, with a diameter of 25 and 2 mm thick, were held at temperatures ranging from 403 to 873 K and exposed to Li/D plasmas under different plasma conditions and fixed total fluences of 5 ×1025 m‑2, with typical particle flux values of (1–5) × 1022 m‑2 s‑1. The deuterium and lithium contents of the samples after irradiation were analyzed by thermal desorption spectroscopy and nuclear reaction analysis (NRA). No lithium deposition was found within the sensitivity range of NRA, except for the cold (403 K) sample on which a layer with Li atomic density below 2 × 1022 m‑2 was detected. Deuterium retention values in the range of 1018 m‑2 were measured, even for the Li deposition conditions.

  1. Determination of metals in composite diet samples by inductively coupled plasma-mass spectrometry.

    Science.gov (United States)

    Melnyk, Lisa Jo; Morgan, Jeffrey N; Fernando, Reshan; Pellizzari, Edo D; Akinbo, Olujide

    2003-01-01

    A study was conducted to evaluate the applicability of inductively coupled plasma-mass spectrometry (ICP-MS) techniques for determination of metals in composite diets. Aluminum, cadmium, chromium, copper, lead, manganese, nickel, vanadium, and zinc were determined by this method. Atmospheric pressure microwave digestion was used to solubilize analytes in homogenized composite diet samples, and this procedure was followed by ICP-MS analysis. Recovery of certified elements from standard reference materials ranged from 92 to 119% with relative standard deviations (RSDs) of 0.4-1.9%. Recovery of elements from fortified composite diet samples ranged from 75 to 129% with RSDs of 0-11.3%. Limits of detection ranged from 1 to 1700 ng/g; high values were due to significant amounts of certain elements naturally present in composite diets. Results of this study demonstrate that low-resolution quadrupole-based ICP-MS provides precise and accurate measurements of the elements tested in composite diet samples.

  2. Spectrochemical analysis of powdered biological samples using transversely excited atmospheric carbon dioxide laser plasma excitation

    Science.gov (United States)

    Zivkovic, Sanja; Momcilovic, Milos; Staicu, Angela; Mutic, Jelena; Trtica, Milan; Savovic, Jelena

    2017-02-01

    The aim of this study was to develop a simple laser induced breakdown spectroscopy (LIBS) method for quantitative elemental analysis of powdered biological materials based on laboratory prepared calibration samples. The analysis was done using ungated single pulse LIBS in ambient air at atmospheric pressure. Transversely-Excited Atmospheric pressure (TEA) CO2 laser was used as an energy source for plasma generation on samples. The material used for the analysis was a blue-green alga Spirulina, widely used in food and pharmaceutical industries and also in a few biotechnological applications. To demonstrate the analytical potential of this particular LIBS system the obtained spectra were compared to the spectra obtained using a commercial LIBS system based on pulsed Nd:YAG laser. A single sample of known concentration was used to estimate detection limits for Ba, Ca, Fe, Mg, Mn, Si and Sr and compare detection power of these two LIBS systems. TEA CO2 laser based LIBS was also applied for quantitative analysis of the elements in powder Spirulina samples. Analytical curves for Ba, Fe, Mg, Mn and Sr were constructed using laboratory produced matrix-matched calibration samples. Inductively coupled plasma optical emission spectroscopy (ICP-OES) was used as the reference technique for elemental quantification, and reasonably well agreement between ICP and LIBS data was obtained. Results confirm that, in respect to its sensitivity and precision, TEA CO2 laser based LIBS can be successfully applied for quantitative analysis of macro and micro-elements in algal samples. The fact that nearly all classes of materials can be prepared as powders implies that the proposed method could be easily extended to a quantitative analysis of different kinds of materials, organic, biological or inorganic.

  3. Aqueous two phase system based on ionic liquid for isolation of quinine from human plasma sample.

    Science.gov (United States)

    Flieger, J; Czajkowska-Żelazko, A

    2015-01-01

    Aqueous two phase system was applied for selective extraction of quinine from human plasma. Bi-phase was constructed from ionic liquid: butyl-methyl-imidazolium chloride after addition kosmotropic salts K₃PO₄ or KH₂PO₄. Quinine was determined in plasma samples after drinking of tonic containing quinine. Determination was performed by HPLC on 5-μm Zorbax SB-CN column and eluent containing 40% acetonitrile (v/v), 20 mM phosphate buffer at pH 3 and 40 mM NaPF₆ using external standard method. The spectrophotometric detection was set λ=214 nm. Selective fluorescence detection was performed at excitation of 325 nm and emission of 375 nm. Proposed strategy provides suitable sample purification and gives extraction yields in the range of 89-106%. The determination coefficient (R(2)) has a value ≥0.997 in the range of 50-800 ng/ml quinine concentration. The limit of quantification was set at 27.9 ng/ml and the detection limit was found to be 8.4 ng/ml under fluorescence detection.

  4. Influence of sample temperature on the expansion dynamics and the optical emission of laser-induced plasma

    Energy Technology Data Exchange (ETDEWEB)

    Eschlböck-Fuchs, S.; Haslinger, M.J.; Hinterreiter, A.; Kolmhofer, P.; Huber, N. [Christian Doppler Laboratory for Laser-Assisted Diagnostics, Institute of Applied Physics, Johannes Kepler University Linz, A-4040 Linz (Austria); Rössler, R. [voestalpine Stahl GmbH, A-4031 Linz (Austria); Heitz, J. [Christian Doppler Laboratory for Laser-Assisted Diagnostics, Institute of Applied Physics, Johannes Kepler University Linz, A-4040 Linz (Austria); Pedarnig, J.D., E-mail: johannes.pedarnig@jku.at [Christian Doppler Laboratory for Laser-Assisted Diagnostics, Institute of Applied Physics, Johannes Kepler University Linz, A-4040 Linz (Austria)

    2013-09-01

    We investigate the influence of sample temperature on the dynamics and optical emission of laser induced plasma for various solid materials. Bulk aluminum alloy, silicon wafer, and metallurgical slag samples are heated to temperature T{sub S} ≤ 500 °C and ablated in air by Nd:YAG laser pulses (wavelength 1064 nm, pulse duration approx. 7 ns). The plasma dynamics is investigated by fast time-resolved photography. For laser-induced breakdown spectroscopy (LIBS) the optical emission of plasma is measured by Echelle spectrometers in combination with intensified CCD cameras. For all sample materials the temporal evolution of plume size and broadband plasma emission vary systematically with T{sub S}. The size and brightness of expanding plumes increase at higher T{sub S} while the mean intensity remains independent of temperature. The intensity of emission lines increases with temperature for all samples. Plasma temperature and electron number density do not vary with T{sub S}. We apply the calibration-free LIBS method to determine the concentration of major oxides in slag and find good agreement to reference data up to T{sub S} = 450 °C. The LIBS analysis of multi-component materials at high temperature is of interest for technical applications, e.g. in industrial production processes. - Highlights: • Size and emission of laser-induced plasma increase with sample temperature Ts. • Mean optical intensity of plasma is independent of Ts. • Plasma temperature and electron number density do not vary with Ts. • Major oxides in steel slag are quantified up to Ts = 450 °C. • Industrial steel slags are analyzed by calibration-free LIBS method.

  5. Automated Sample Preparation Platform for Mass Spectrometry-Based Plasma Proteomics and Biomarker Discovery

    Directory of Open Access Journals (Sweden)

    Vilém Guryča

    2014-03-01

    Full Text Available The identification of novel biomarkers from human plasma remains a critical need in order to develop and monitor drug therapies for nearly all disease areas. The discovery of novel plasma biomarkers is, however, significantly hampered by the complexity and dynamic range of proteins within plasma, as well as the inherent variability in composition from patient to patient. In addition, it is widely accepted that most soluble plasma biomarkers for diseases such as cancer will be represented by tissue leakage products, circulating in plasma at low levels. It is therefore necessary to find approaches with the prerequisite level of sensitivity in such a complex biological matrix. Strategies for fractionating the plasma proteome have been suggested, but improvements in sensitivity are often negated by the resultant process variability. Here we describe an approach using multidimensional chromatography and on-line protein derivatization, which allows for higher sensitivity, whilst minimizing the process variability. In order to evaluate this automated process fully, we demonstrate three levels of processing and compare sensitivity, throughput and reproducibility. We demonstrate that high sensitivity analysis of the human plasma proteome is possible down to the low ng/mL or even high pg/mL level with a high degree of technical reproducibility.

  6. Pregnancy-associated glycoprotein (PAG) concentration in plasma and milk samples for early pregnancy diagnosis in Lacaune dairy sheep.

    Science.gov (United States)

    El Amiri, B; Sousa, N M; Alvarez Oxiley, A; Hadarbach, D; Beckers, J F

    2015-04-01

    In the present study, four RIA systems (RIA-1 to -4) based on two antisera raised against ovine pregnancy-associated glycoproteins (ovPAGs), combined with an ovine or a bovine PAG tracer were used to measure PAG concentrations in plasma and milk samples of dairy ewes. Blood and milk samples were collected on different days of gestation: 0, 18, 20, 22, 25, 28, 32, 42, and 49. From day 20 onward, the PAG in plasma could be detected in all pregnant ewes using the four RIA systems. By using milk, except for RIA-1, the other systems showed a sensitivity of 100% from day 28 of gestation onward. In plasma, PAG concentrations were higher in multiple than in single pregnancies, while no clear relationship was observed in milk. In conclusion, milk is a good alternative to plasma for early pregnancy diagnosis in sheep from day 28 to day 42.

  7. Thermal analysis of the influence of the support in the superficial treatment by plasma of cylindrical samples

    Energy Technology Data Exchange (ETDEWEB)

    Belisio, A.S.; Lima, J.A.; Alves Junior, C. [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil). Programa de Pos-Graduacao em Engenharia Mecanica]. E-mails: abelisio@yahoo.com.br; jalima@dem.ufrn.br; alvesjr@dem.ufrn.br

    2008-07-01

    Different of the conventional processes of heating, that is, transport, convection, and radiation, heat transfer in heating process by plasma also occur also by collisions of particles, in other words, through the transfer heat motion ions for the surface of the sample, the kinetic energy, and potential those particles, as well as the enthalpy of the chemical reactions involved in the surface. In thermal plasmas, that transfer can to be simplified initially through general energy balance between plasma and samples. However, existent models of temperature distribution are in its majority unidimensional and it do not analyze, mainly, support influence on sample in the heating process by r plasma. In that way, with the mark of analyzing the temperature distribution in the samples submitted to polarization voltage of 706 V, 744 V and 790 V, as well as process heating support influence analysis those samples, the present work developed a code computational for a transient (2D-t) two-dimensional model, destined to the simulation of the heat transfer during heating phases and cooling in superficial process of treatment by plasma in cylindrical samples of copper, being considered the configuration of hollow cathode and the presence of a support. The model computational serves as a tool in the predict of the final properties of treated samples, well as in the specification of the parameters of the heating processes by plasma. In the developed model was considered that the physical samples properties were variable, functions of the temperature field. The results obtained through simulation are leaning and validated in experimental and theoretical data available in the literature, as well as, in information of tests accomplished in Lab Plasma/ UFRN. (author)

  8. Plasma Free Metanephrines

    Science.gov (United States)

    ... be limited. Home Visit Global Sites Search Help? Plasma Free Metanephrines Share this page: Was this page helpful? Also known as: Plasma Metanephrines Formal name: Fractionated Plasma Free Metanephrines (Metanephrine ...

  9. Improved plasma accelerator

    Science.gov (United States)

    Cheng, D. Y.

    1971-01-01

    Converging, coaxial accelerator electrode configuration operates in vacuum as plasma gun. Plasma forms by periodic injections of high pressure gas that is ionized by electrical discharges. Deflagration mode of discharge provides acceleration, and converging contours of plasma gun provide focusing.

  10. Plasma physics and fusion plasma electrodynamics

    CERN Document Server

    Bers, Abraham

    2016-01-01

    Plasma is a ubiquitous state of matter at high temperatures. The electrodynamics of plasmas encompasses a large number of applications, from understanding plasmas in space and the stars, to their use in processing semiconductors, and their role in controlled energy generation by nuclear fusion. This book covers collective and single particle dynamics of plasmas for fully ionized as well as partially ionized plasmas. Many aspects of plasma physics in current fusion energy generation research are addressed both in magnetic and inertial confinement plasmas. Linear and nonlinear dynamics in hydrodynamic and kinetic descriptions are offered, making both simple and complex aspects of the subject available in nearly every chapter. The approach of dividing the basic aspects of plasma physics as "linear, hydrodynamic descriptions" to be covered first because they are "easier", and postponing the "nonlinear and kinetic descriptions" for later because they are "difficult" is abandoned in this book. For teaching purpose...

  11. Stable isotope dilution analysis of hydrologic samples by inductively coupled plasma mass spectrometry

    Science.gov (United States)

    Garbarino, J.R.; Taylor, H.E.

    1987-01-01

    Inductively coupled plasma mass spectrometry is employed in the determination of Ni, Cu, Sr, Cd, Ba, Ti, and Pb in nonsaline, natural water samples by stable isotope dilution analysis. Hydrologic samples were directly analyzed without any unusual pretreatment. Interference effects related to overlapping isobars, formation of metal oxide and multiply charged ions, and matrix composition were identified and suitable methods of correction evaluated. A comparability study snowed that single-element isotope dilution analysis was only marginally better than sequential multielement isotope dilution analysis. Accuracy and precision of the single-element method were determined on the basis of results obtained for standard reference materials. The instrumental technique was shown to be ideally suited for programs associated with certification of standard reference materials.

  12. ENO1 Protein Levels in the Tumor Tissues and Circulating Plasma Samples of Non-small Cell Lung Cancer Patients

    Directory of Open Access Journals (Sweden)

    Ying ZHANG

    2010-12-01

    Full Text Available Background and objective Proper tumor markers are useful to diagnosis, prognosis and treatment for lung cancer. The aim of this study is to examine the levels of alpha-enolase (ENO1 protein in the tumor tissues and peripheral plasma samples obtained from non-small cell lung cancer (NSCLC patients, and evaluate its potential clinical significance. Methods The ENO1 protein levels in the tumor tissues and corresponding normal tissues from 16 cases of lung squamous cell carcinoma were analyzed by Western blot. The ENO1 protein levels in the plasma samples from 42 healthy individuals, 34 patients with lung benign disease and 84 patients with NSCLC were measured by double antibody sandwich enzyme-linked immunosorbent assay. Results For 87.5% (14/16 of the patients with lung squamous cell carcinoma, the ENO1 protein level in the tumor tissues was higher than that in the corresponding normal lung tissues. The ENO1 protein level in the plasma of NSCLC patients was significantly higher than that in the plasma of healthy individuals (P=0.031 and patients with lung benign disease (P=0.019. Furthermore, the ENO1 protein level was significantly higher in the plasma of patients with lung adenocarcinoma than that of patients with lung squamous cell carcinoma. Conclusion The elevated levels of ENO1 protein in the tumor tissues and the plasma samples from NSCLC patients indicate ENO1 may be a candidate biomarker of lung cancer.

  13. Closed inductively coupled plasma cell

    Science.gov (United States)

    Manning, Thomas J.; Palmer, Byron A.; Hof, Douglas E.

    1990-01-01

    A closed inductively coupled plasma cell generates a relatively high power, low noise plasma for use in spectroscopic studies. A variety of gases can be selected to form the plasma to minimize spectroscopic interference and to provide a electron density and temperature range for the sample to be analyzed. Grounded conductors are placed at the tube ends and axially displaced from the inductive coil, whereby the resulting electromagnetic field acts to elongate the plasma in the tube. Sample materials can be injected in the plasma to be excited for spectroscopy.

  14. Understanding Micro Plasmas

    CERN Document Server

    Winter, J; Böke, M; Ellerweg, D; Hemke, T; Knake, N; Mussenbrock, T; Niermann, B; Schröder, D; der Gathen, V Schulz-von; von Keudell, A

    2011-01-01

    Micro plasmas are operated around atmospheric pressure exhibiting pronounced non-equilibrium characteristics, i.e. they possess energetic electrons while ions and neutrals remain cold. They have gained significant interest due to their enormous application potential e.g. in the biomedical, surface modification and light source areas, just to name a few. Many different configurations are in use. Their understanding and quantification is mandatory for further progress in applications. We report on recent progress in the diagnostics and simulation of the entire micro plasma system from gas introduction, via the plasma discharge up to the samples at the example of a plasma jet operated in He/O2 in an ambient air environment.

  15. Study of plasma amino acid levels in children with autism: An Egyptian sample

    Directory of Open Access Journals (Sweden)

    Farida M. ElBaz

    2014-04-01

    Conclusions: Autistic children had lower levels of some plasma amino acids except for glycine and glutamic acids and phosphoserine were increased with normal serum levels of urea, ammonia, total proteins, albumin and globulins (alpha 1, alpha 2, beta and gamma.

  16. Oxygen bomb combustion of biological samples for inductively coupled plasma optical emission spectrometry

    Science.gov (United States)

    Souza, Gilberto B.; Carrilho, Elma Neide V. M.; Oliveira, Camila V.; Nogueira, Ana Rita A.; Nóbrega, Joaquim A.

    2002-12-01

    A rapid sample preparation method is proposed for decomposition of milk powder, corn bran, bovine and fish tissues, containing certified contents of the analytes. The procedure involves sample combustion in a commercial stainless steel oxygen bomb operating at 25 bar. Most of the samples were decomposed within 5 min. Diluted nitric acid or water-soluble tertiary amines 10% v/v were used as absorption solutions. Calcium, Cu, K, Mg, Na, P, S and Zn were recovered with the bomb washings and determined by inductively coupled plasma optical emission spectrometry (ICP-OES). Ethanol mixed with paraffin was used as a combustion aid to allow complete combustion. A cooling step prior releasing of the bomb valve was employed to increase the efficiency of sample combustion. Iodine was also determined in milk samples spiked with potassium iodide to evaluate the volatilization and collection of iodine in amine CFA-C medium and the feasibility of its determination by ICP-OES with axial view configuration. Most of the element recoveries in the samples were between 91 and 105% and the certified and found contents exhibited a fair agreement at a 95% confidence level.

  17. Measurement of glomerular filtration rate in adults: accuracy of five single-sample plasma clearance methods

    DEFF Research Database (Denmark)

    Rehling, M; Rabøl, A

    1989-01-01

    After an intravenous injection of a tracer that is removed from the body solely by filtration in the kidneys, the glomerular filtration rate (GFR) can be determined from its plasma clearance. The method requires a great number of blood samples but collection of urine is not needed. In the present......-acetate) was determined simultaneously. Using these clearance values as reference the accuracy of six simplified methods were studied: five single-sample methods and one five-sample method. The standard error of estimate (SEE) of the single-sample methods ranged from 4.2 to 7.5 ml min-1 using EDTA, and from 3.8 to 6.3 ml...... min-1 using DTPA. SEE of the five-samples method was 3.0 ml min-1 (EDTA) and 3.1 ml min-1 (DTPA). The single-sample methods given by Christensen & Groth (1986) and by Tauxe (1986) are recommended for daily use, as SEE was small even at low GFR values. In patients with GFR less than 80 ml min-1...

  18. Effects of Long-Term Storage Time and Original Sampling Month on Biobank Plasma Protein Concentrations.

    Science.gov (United States)

    Enroth, Stefan; Hallmans, Göran; Grankvist, Kjell; Gyllensten, Ulf

    2016-10-01

    The quality of clinical biobank samples is crucial to their value for life sciences research. A number of factors related to the collection and storage of samples may affect the biomolecular composition. We have studied the effect of long-time freezer storage, chronological age at sampling, season and month of the year and on the abundance levels of 108 proteins in 380 plasma samples collected from 106 Swedish women. Storage time affected 18 proteins and explained 4.8-34.9% of the observed variance. Chronological age at sample collection after adjustment for storage-time affected 70 proteins and explained 1.1-33.5% of the variance. Seasonal variation had an effect on 15 proteins and month (number of sun hours) affected 36 proteins and explained up to 4.5% of the variance after adjustment for storage-time and age. The results show that freezer storage time and collection date (month and season) exerted similar effect sizes as age on the protein abundance levels. This implies that information on the sample handling history, in particular storage time, should be regarded as equally prominent covariates as age or gender and need to be included in epidemiological studies involving protein levels.

  19. Isotope labeled internal standards (ILIS) as a basis for quality control in clinical studies using plasma samples.

    Science.gov (United States)

    Rezeli, Melinda; Végvári, Akos; Marko-Varga, György; Laurell, Thomas

    2010-04-18

    For clinical proteomic studies, the quality of the biofluid samples such as human blood plasma is extremely important. In this study we have investigated the stability of human plasma samples by spiking stable isotope-labeled peptides into the plasma and monitoring their degradation under different storage conditions. FPA-1, C4A and C3f were synthesized with isotopically labeled amino acids, and used as reference peptides. The mixture of internal calibrants was spiked into plasma at the starting point of investigation, mimicking the time of collection for future biobanking efforts, and their qualitative and quantitative changes were analyzed over time by using both MALDI-MS (LTQ Orbitrap XL) and nanoLC-ESI-MS (LTQ XL ETD). We have found that all three synthetic peptides were stable in plasma at -20 and -80 degrees C during the examined 2-month period. However, different proteolytic degradation profiles of the peptides were observed at room temperature. We anticipate that the use of these isotope-labeled peptides as internal standards (ILIS) provides a quality control for long-term storage and proteomic plasma analysis.

  20. Separation and Determination of Methylnaltrexone in Human Plasma Samples After Oral Administration by HPLC Coupled with Electrochemical Detection

    Institute of Scientific and Technical Information of China (English)

    WANG An-bao; Joseph F. Foss; YUAN Chun-su; Joachim Osinski

    2005-01-01

    A high performance liquid chromatography(HPLC) method coupled with electrochemical detection and solid phase extraction is described for the separation and determination of methylnaltrexone(MNTX), a quaternary opioid antagonist, in human clinical plasma samples after oral administration. Linearity of the standard curve for MNTX was found in the range of 4.0_150 ng/mL and was statistically conformed. The correlation coefficient(r2) and calibration equation obtained from linear regression analysis are 0.9999 and Y=54.27X-0.22, where Y and X represent the peak area and concentration of MNTX, respectively. The detection limit of MNTX under the present experimental conditions is 2.0 ng/mL by estimating at a ratio of 3 of signal to noise. The mean recovery of MNTX in human plasma is higher than 97%. The analytical method was applied to the pharmacokinetic determination of MNTX after single dose oral administration. These data demonstrate that the change of MNTX plasma concentration versus time is obvious. MNTX level of plasma reaches to a plateau between 45 to 120 minutes and then falls slowly. The content of MNTX in plasma sample maintains at an obviously detectable level after twelve hours of oral administration. The pharmacokinetic parameters for a single dose of 19.2 mg/kg in plasma are cmax=206.42(±16.53) ng/mL and tmax=60 min.

  1. Fusion plasma physics

    CERN Document Server

    Stacey, Weston M

    2012-01-01

    This revised and enlarged second edition of the popular textbook and reference contains comprehensive treatments of both the established foundations of magnetic fusion plasma physics and of the newly developing areas of active research. It concludes with a look ahead to fusion power reactors of the future. The well-established topics of fusion plasma physics -- basic plasma phenomena, Coulomb scattering, drifts of charged particles in magnetic and electric fields, plasma confinement by magnetic fields, kinetic and fluid collective plasma theories, plasma equilibria and flux surface geometry, plasma waves and instabilities, classical and neoclassical transport, plasma-materials interactions, radiation, etc. -- are fully developed from first principles through to the computational models employed in modern plasma physics. The new and emerging topics of fusion plasma physics research -- fluctuation-driven plasma transport and gyrokinetic/gyrofluid computational methodology, the physics of the divertor, neutral ...

  2. Sample selection algorithm to improve quality of genotyping from plasma-derived DNA: to separate the wheat from the chaff.

    Science.gov (United States)

    Schoenborn, Veit; Gohlke, Henning; Heid, Iris M; Illig, Thomas; Utermann, Gerd; Kronenberg, Florian

    2007-11-01

    Plasma and serum samples were often the only biological material collected for earlier epidemiological studies. These studies have a huge informative content, especially due to their long follow-up and would be an invaluable treasure for genetic investigations. However, often no banked DNA is available. To use the small amounts of DNA present in plasma, in a first step, we applied magnetic bead technology to extract this DNA, followed by a whole-genome amplification (WGA) using phi29-polymerase. We assembled 88 sample pairs, each consisting of WGA plasma DNA and the corresponding whole-blood DNA. We genotyped nine highly polymorphic short tandem repeats (STRs) and 23 SNPs in both DNA sources. The average within-pair discordance was 3.8% for SNPs and 15.9% for STR genotypes, respectively. We developed an algorithm based on one-half of the sample pairs and validated on the other one-half to identify the samples with high WGA plasma DNA quality to assure low genotyping error and to exclude plasma DNA samples with insufficient quality: excluding samples showing homozygosity at five or more of the nine STR loci yielded exclusion of 22.7% of all samples and decreased average discordance for STR and SNP markers to 3.92% and 0.63%, respectively. For SNPs, this is very close to the error observed for genomic DNA in many laboratories. Our workflow and sample selection algorithm offers new opportunities to recover reliable DNA from stored plasma material. This algorithm is superior to testing the amount of input DNA.

  3. A Movable Mass Spectroscopy Sampling Apparatus for Measuring Spatial Distribution of Neutral Radicals in Silane Plasma

    Institute of Scientific and Technical Information of China (English)

    WANG Zhao-Kui; LIN Kui-Xun; LIN Xuan-Ying; QIU Gui-Ming; ZHU Zu-Song

    2005-01-01

    @@ A movable mass spectroscopy gas sampling apparatus has been established and a straight-line fit ofsilane depletion fraction f is proposed.The spatial density distributions of SiHn (n = 0-3) radicals in silane radio frequency glow discharge have been measured by a mass spectrometer.The experimental results demonstrate that the densities of the neutral radicals have the peak value near the middle position of electrodes, and the densities of SiH2 and SiHs are higher than those of Si and SiH in silane plasma.This reveals that SiH2 and SiH3 may be the primary precursors in forming the a-Si:H film.

  4. International movement of plasma and plasma contracting.

    Science.gov (United States)

    Farrugia, A

    2005-01-01

    Plasma fractionation is a global business characterised by technological stability, increasing consolidation and a high level of regulatory oversight. All these factors affect the ease with which plasma derivatives can be accessed in the world market. As domestic regulatory measures in the first world blood economies become increasingly resonant to the precautionary approach, the availability of plasma as a raw material, as well as its cost, become an increasingly significant component in the cost of the final product. This decreases the amount of plasma which fractionators are able to allocate for export activities. Also, regulatory standards in the country of manufacture will reflect priorities in that country which may not be similar to those in export markets, but which will affect entry to those markets. While many countries possess a fractionation capacity, the limiting factor in supply worldwide is the amount of plasma available, and nationalistic drivers for each country to have its own plant are inimical to product safety and supply. Rather, the provision of sufficient supplies of domestic plasma should be the focus of resource allocation, with a choice of an appropriate contract fractionator. However, contract fractionation too may be affected by domestic considerations unrelated to the needs of the country of plasma origin. This chapter will review the global plasma market and the influences on plasma and plasma product movement across national borders. Problems in ensuring adequate safety and supply will be identified, and some tentative approaches to the amelioration of current barriers to the provision of plasma derivatives will be outlined.

  5. Comparison of ESR1 Mutations in Tumor Tissue and Matched Plasma Samples from Metastatic Breast Cancer Patients

    Directory of Open Access Journals (Sweden)

    Takashi Takeshita

    2017-10-01

    Full Text Available BACKGROUND: ESR1 mutation in circulating cell-free DNA (cfDNA is emerging as a noninvasive biomarker of acquired resistance to endocrine therapy, but there is a paucity of data comparing the status of ESR1 gene in cfDNA with that in its corresponding tumor tissue. The objective of this study is to validate the degree of concordance of ESR1 mutations between plasma and tumor tissue. METHODS: ESR1 ligand-binding domain mutations Y537S, Y537N, Y537C, and D538G were analyzed using droplet digital PCR in 35 patients with metastatic breast cancer (MBC (35 tumor tissue samples and 67 plasma samples. RESULTS: Of the 35 paired samples, 26 (74.3% were concordant: one patient had detectable ESR1 mutations both plasma (ESR1 Y537S/Y537N and tumor tissue (ESR1 Y537S/Y537C, and 25 had WT ESR1 alleles in both. Nine (25.7% had discordance between the plasma and tissue results: five had mutations detected only in their tumor tissue (two Y537S, one Y537C, one D538G, and one Y537S/Y537N/D538G, and four had mutations detected only in their plasma (one Y537S, one Y537N, and two Y537S/Y537N/D538G. Furthermore, longitudinal plasma samples from 19 patients were used to assess changes in the presence of ESR1 mutations during treatment. Eleven patients had cfDNA ESR1 mutations over the course of treatment. A total of eight of 11 patients with MBC with cfDNA ESR1 mutations (72.7% had the polyclonal mutations. CONCLUSION: We have shown the independent distribution of ESR1 mutations between plasma and tumor tissue in 35 patients with MBC.

  6. Optimization of a miniaturized DBD plasma chip for mercury detection in water samples.

    Science.gov (United States)

    Abdul-Majeed, Wameath S; Parada, Jaime H Lozano; Zimmerman, William B

    2011-11-01

    In this work, an optimization study was conducted to investigate the performance of a custom-designed miniaturized dielectric barrier discharge (DBD) microplasma chip to be utilized as a radiation source for mercury determination in water samples. The experimental work was implemented by using experimental design, and the results were assessed by applying statistical techniques. The proposed DBD chip was designed and fabricated in a simple way by using a few microscope glass slides aligned together and held by a Perspex chip holder, which proved useful for miniaturization purposes. Argon gas at 75-180 mL/min was used in the experiments as a discharge gas, while AC power in the range 75-175 W at 38 kHz was supplied to the load from a custom-made power source. A UV-visible spectrometer was used, and the spectroscopic parameters were optimized thoroughly and applied in the later analysis. Plasma characteristics were determined theoretically by analysing the recorded spectroscopic data. The estimated electron temperature (T(e) = 0.849 eV) was found to be higher than the excitation temperature (T(exc) = 0.55 eV) and the rotational temperature (T(rot) = 0.064 eV), which indicates non-thermal plasma is generated in the proposed chip. Mercury cold vapour generation experiments were conducted according to experimental plan by examining four parameters (HCl and SnCl(2) concentrations, argon flow rate, and the applied power) and considering the recorded intensity for the mercury line (253.65 nm) as the objective function. Furthermore, an optimization technique and statistical approaches were applied to investigate the individual and interaction effects of the tested parameters on the system performance. The calculated analytical figures of merit (LOD = 2.8 μg/L and RSD = 3.5%) indicates a reasonable precision system to be adopted as a basis for a miniaturized portable device for mercury detection in water samples.

  7. Analysis of liquid samples using dried-droplet laser ablation inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Do, Trong-Mui; Hsieh, Hui-Fang; Chang, Wei-Ciang [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, 30013 Taiwan (China); Chang, E.-E. [Department of Biochemistry, Taipei Medical University, Taipei City, 11031 Taiwan (China); Wang, Chu-Fang, E-mail: cfwang@mx.nthu.edu.tw [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, 30013 Taiwan (China); Institute of Nuclear Engineering and Science, National Tsing Hua University, Hsinchu 30013, Taiwan (China)

    2011-08-15

    In this study we developed a dried-droplet method for laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The proposed method provides accurate and precise results when building calibration curves and determining elements of interest in real liquid samples. After placing just 1 {mu}L of a liquid standard solution or a real sample onto the filter surface and then converting the solution into a very small, thin dry spot, the sample could be applied as an analytical subject for LA. To demonstrate the feasibility of this proposed method, we used LA-ICP-MS and conventional ICP-MS to determine the levels of 13 elements (Li, V, Mn, Co, Ni, Cu, Zn, As, Mo, Cd, Sb, Tl, and Pb) in five water samples. The correlation coefficients obtained from the various calibration curves ranged from 0.9920 ({sup 205}Tl) to 0.9998 ({sup 51}V), sufficient to allow the determination of a wide range of elements in the samples. We also investigated the effects of Methylene Blue (MB) and the NaCl concentration on the elemental analyses. MB could be used as an indicator during the ablation process; its presence in the samples only negligibly influenced the intensities of the signals of most of the tested elements. Notably, high NaCl contents led to signal suppression for some of the elements. In comparison with the established sample introduction by nebulization, our developed technique abrogates the need for time-consuming sample preparation and reduces the possibility of sample contamination.

  8. Demonstration of a frozen sample aliquotter to prepare plasma and serum aliquots without thawing frozen parent samples.

    Science.gov (United States)

    Ellis, Helena Judge; Venturini, Deborah S

    2013-06-01

    Human biospecimens represent invaluable resources to advance molecular medicine, epidemiology, and biomarker discovery/validation, among other biomedical research. Biobanks typically cryopreserve biospecimens to safeguard their biochemical composition. However, exposing specimens repeatedly to freeze/thaw cycles can degrade their integrity in unforeseen ways. Those biobanks storing liquid samples, thus, regularly make a fundamental compromise at collection time between freezing samples in many small volumes (e.g., 0.5 mL or smaller) or in fewer, larger volumes (e.g., 1.8 mL). The former eliminates the need to expose samples to repeated freeze/thaw cycling, although increasing up-front labor costs, consumables used, and cold storage space requirements. The latter decreases up-front labor costs, consumables, and cold storage requirements, yet exposes samples repeatedly to damaging freeze/thaw cycles when smaller aliquots are needed for analysis. The Rhode Island BioBank at Brown University (RIBB) thoroughly evaluated the performance of an original technology that minimizes a sample's exposure to freeze/thaw cycling by enabling the automated extraction of frozen aliquots from one single frozen parent sample without thawing it. A technology that eliminates unnecessary sample exposures to freeze/thaw cycles could help protect sample integrity, extend its useful life, and effectively rectify and eliminate the aforementioned need to compromise. This report presents the results of the evaluation, and conclusively demonstrates the technology's ability to extract multiple uniform frozen aliquots from a single cryotube of never-thawed frozen human plasma, which faithfully represent the parent sample when analyzed for typical biochemical analytes, showing a coefficient of variability lower than 5.5%.

  9. Fast determination of paraquat in plasma and urine samples by solid-phase microextraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Gao, Lina; Liu, Junting; Wang, Chunyuan; Liu, Guojie; Niu, Xiaodong; Shu, Cuixia; Zhu, Juan

    2014-01-01

    A simple, sensitive and reliable gas chromatographic-mass spectrometric method (GC-MS) for quantifying paraquat concentration in biological samples has been developed, using ethyl paraquat as an internal standard. The method involved the procedures of sodium borohydride-nickel chloride (NaBH4-NiCl2) reduction and solid-phase microextraction (SPME) of the perhydrogenated products. GC-MS was used to identify and quantify the analytes in selected ion monitoring (SIM) mode. Under the optimal conditions, recoveries in plasma and urine samples were 94.00-99.85% and 95.00-100.34%, respectively. Excellent sample clean-up was observed and good linearities (r=0.9982 for plasma sample and 0.9987 for urine sample) were obtained in the range of 0.1-50μg/mL. The limits of detection (S/N=3) were 0.01μg/mL in plasma and urine samples. The intra-day precision was less than 8.43%, 4.19% (n=3), and inter-day precision was less than 10.90%, 10.49% (n=5) for plasma and urine samples, respectively. This method was successfully applied to the analysis of the biological samples collected from a victim who died as a result of ingestion of paraquat.

  10. A lipemia-independent NanoDrop(®)-based score to identify hemolysis in plasma and serum samples.

    Science.gov (United States)

    Appierto, Valentina; Callari, Maurizio; Cavadini, Elena; Morelli, Daniele; Daidone, Maria Grazia; Tiberio, Paola

    2014-05-01

    The identification and management of hemolyzed samples are crucial issues in the development of new blood-based biomarkers. Using experiments of controlled hemolysis and lipemia and two plasma series from cancer patients, we developed and validated a lipemia-independent hemolysis score (HS). HS resulted strictly associated with the amount of lysed erythrocytes and with serum index measurement (reference method), highly reproducible, and able to identify as hemolyzed plasma/serum samples containing ≥6.1 mg/dl of free hemoglobin. We developed a simple, robust, sensitive, cost-effective, spectrophotometrically-based system to identify hemolyzed plasma/serum specimens. The procedure requires only 2 μl of sample, thus representing a useful tool for research studies and an essential pre-analytical quality control for an optimal biobanking of liquid biopsies.

  11. Communication through Plasma Sheaths

    CERN Document Server

    Korotkevich, A O; Zakharov, V E

    2007-01-01

    We wish to transmit messages to and from a hypersonic vehicle around which a plasma sheath has formed. For long distance transmission, the signal carrying these messages must be necessarily low frequency, typically 2 GHz, to which the plasma sheath is opaque. The idea is to use the plasma properties to make the plasma sheath appear transparent.

  12. LacaScore: a novel plasma sample quality control tool based on ascorbic acid and lactic acid levels.

    Science.gov (United States)

    Trezzi, Jean-Pierre; Bulla, Alexandre; Bellora, Camille; Rose, Michael; Lescuyer, Pierre; Kiehntopf, Michael; Hiller, Karsten; Betsou, Fay

    Metabolome analysis is complicated by the continuous dynamic changes of metabolites in vivo and ex vivo. One of the main challenges in metabolomics is the robustness and reproducibility of results, partially driven by pre-analytical variations. The objective of this study was to analyse the impact of pre-centrifugation time and temperature, and to determine a quality control marker in plasma samples. Plasma metabolites were measured by gas chromatography-mass spectrometry (GC-MS) and analysed with the MetaboliteDetector software. The metabolites, which were the most labile to pre-analytical variations, were further measured by enzymatic assays. A score was calculated for their use as quality control markers. The pre-centrifugation temperature was shown to be critical in the stability of plasma samples and had a significant impact on metabolite concentration profiles. In contrast, pre-centrifugation delay had only a minor impact. Based on the results of this study, whole blood should be kept on wet ice and centrifuged within maximum 3 h as a prerequisite for preparing EDTA plasma samples fit for the purpose of metabolome analysis. We have established a novel blood sample quality control marker, the LacaScore, based on the ascorbic acid to lactic acid ratio in plasma, which can be used as an indicator of the blood pre-centrifugation conditions, and hence the suitability of the sample for metabolome analyses. This method can be applied in research institutes and biobanks, enabling assessment of the quality of their plasma sample collections.

  13. Introduction to plasma dynamics

    CERN Document Server

    Morozov, A I

    2013-01-01

    As the twenty-first century progresses, plasma technology will play an increasing role in our lives, providing new sources of energy, ion-plasma processing of materials, wave electromagnetic radiation sources, space plasma thrusters, and more. Studies of the plasma state of matter not only accelerate technological developments but also improve the understanding of natural phenomena. Beginning with an introduction to the characteristics and types of plasmas, Introduction to Plasma Dynamics covers the basic models of classical diffuse plasmas used to describe such phenomena as linear and shock w

  14. Effect of piperine on pharmacokinetics of sodium valproate in plasma samples of rats using gas chromatography-mass spectrometry method

    Directory of Open Access Journals (Sweden)

    Bushra Parveen

    2015-01-01

    Full Text Available Piperine (PIP is used as anticonvulsant in traditional Chinese medicine. Co-administration of low-dose sodium valproate with PIP has been regarded to have potential anticonvulsant activity. Aim: This study was intended to investigate the effect of PIP on the pharmacokinetics of sodium valproate (SVP in the plasma samples of rats using gas chromatography-mass spectrometry (GC-MS method. Materials and Methods: The plasma samples obtained after oral administration of SVP, 150 mg/kg and SVP, 150 mg/kg + PIP, and 5 mg/kg to male Wistar rats were used to quantify the concentrations in plasma using GC-MS method. Results: A simple and accurate method developed in-house was applied for the analysis of plasma samples of Wistar rats after oral administration of SVP and PIP + sodium valproate, respectively. The pharmacokinetic parameters reported 14.8-fold increase in plasma concentration (maximum observed concentration in the concentration-time profile, 4.6-fold increase in area under the curve and slightly prolonged time to reach that concentration (1 h of SVP in presence of PIP. Conclusion: The study reaffirms the bioenhancing effect of PIP suggesting possibility of dose reduction of SVP while co-adminstering with PIP.

  15. Comparison of a new blood sampling device with the vacuum tube system for plasma and hematological analyses in healthy dogs.

    Science.gov (United States)

    Reynolds, Brice S; Boudet, Karine G; Faucher, Mathieu R; Geffre, Anne; Germain, Claude; Lefebvre, Hervé P

    2008-01-01

    Pediatric devices based on a capillary system may provide an alternative to vacuum tubes for canine blood sampling. The potential advantages are absence of vein collapse, limited blood volume sampled, and improved safety. The aim of this study was to compare routine plasma and hematological variables in seven healthy dogs using both techniques. Five biochemical analytes were measured, and a complete hematological examination and plasma exogenous creatinine clearance test were performed. No clinically relevant difference between the two techniques was observed for any variable or functional test assessed.

  16. Collisionless plasmas in astrophysics

    CERN Document Server

    Belmont, Gerard; Mottez, Fabrice; Pantellini, Filippo; Pelletier, Guy

    2013-01-01

    Collisionless Plasmas in Astrophysics examines the unique properties of media without collisions in plasma physics. Experts in this field, the authors present the first book to concentrate on collisionless conditions in plasmas, whether close or not to thermal equilibrium. Filling a void in scientific literature, Collisionless Plasmas in Astrophysics explains the possibilities of modeling such plasmas, using a fluid or a kinetic framework. It also addresses common misconceptions that even professionals may possess, on phenomena such as "collisionless (Landau) damping". Abundant illustrations

  17. Determination of uranium from nuclear fuel in environmental samples using inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Boulyga, S.F. [Forschungszentrum Juelich GmbH (Germany). Zentralabteilung fuer Chemische Analysen]|[Radiation Physics and Chemistry Problems Inst., Minsk (Belarus); Becker, J.S. [Forschungszentrum Juelich GmbH (Germany). Zentralabteilung fuer Chemische Analysen

    2000-11-01

    As a result of the accident at the Chernobyl nuclear power plant (NPP) the environment was contaminated with spent nuclear fuel. The {sup 236}U isotope was used in this study to monitor the spent uranium from nuclear fallout in soil samples collected in the vicinity of the Chernobyl NPP. A rapid and sensitive analytical procedure was developed for uranium isotopic ratio measurement in environmental samples based on inductively coupled plasma quadrupole mass spectrometry with a hexapole collision cell (HEX-ICP-QMS). The figures of merit of the HEX-ICP-QMS were studied with a plasma-shielded torch using different nebulizers (such as an ultrasonic nebulizer (USN) and Meinhard nebulizer) for solution introduction. A {sup 238}U{sup +} ion intensity of up to 27000 MHz/ppm in HEX-ICP-QMS with USN was observed by introducing helium into the hexapole collision cell as the collision gas at a flow rate of 10 ml min{sup -1}. The formation rate of uranium hydride ions UH{sup +}/U{sup +} of 2 x 10{sup -6} was obtained by using USN with a membrane desolvator. The limit of {sup 236}U/{sup 238}U ratio determination in 10 {mu}g 1{sup -1} uranium solution was 3 x 10{sup -7} corresponding to the detection limit for {sup 236}U of 3 pg 1{sup -1}. The precision of uranium isotopic ratio measurements in 10 {mu}g 1{sup -1} laboratory uranium isotopic standard solution was 0.13% ({sup 235}U/{sup 238}U) and 0.33% ({sup 236}U/{sup 238}U) using a Meinhard nebulizer and 0.45% ({sup 235}U/{sup 238}U) and 0.88% ({sup 236}U/{sup 238}U) using a USN. The isotopic composition of all investigated Chernobyl soil samples differed from those of natural uranium; i.e. in these samples the {sup 236}U/{sup 238}U ratio ranged from 10{sup -5} to 10{sup -3}. (orig.)

  18. Determination of trace elements in refined gold samples by inductively coupled plasma atomic emission spectrometry

    Directory of Open Access Journals (Sweden)

    Steharnik Mirjana

    2013-01-01

    Full Text Available This paper presents a method for determination the trace contents of silver, copper, iron, palladium, zinc and platinum in refined gold samples. Simultaneous inductively coupled plasma atomic emission spectrometer with radial torch position and cross flow nebulizer was used for determination. In order to compare the different calibration strategies, two sets of calibration standards were prepared. The first set was based on matrix matched calibration standards and the second was prepared without the addition of matrix material. Detection limits for matrix matching calibrations were higher for some elements than those without matrix matching. In addition, the internal standardization method was applied and experiments indicated that indium was the best option as internal standard. The obtained results for gold sample by matrix matching and matrix free calibrations were compared with the obtained results by standard addition method. The accuracy of the methods was tested performing recovery test. Recoveries for spiked sample were in the range of 90-115 %. The accuracy of the methods was also tested by analysis of certified reference material of high pure goldAuGHP1. The best results were achieved by matrix free calibration and standard addition method using indium as internal standard at wavelength of 230 nm. [Projekat Ministarstva nauke Republike Srbije, br. 34024: Development of Technologies for Recycling of Precious, Rare and Associated Metals from Solid Waste in Serbia to High Purity Products

  19. Pretreatment of plasma samples by a novel hollow fiber centrifugal ultrafiltrate device for the determination of cefaclor concentrations in human plasma.

    Science.gov (United States)

    Li, Jun-Mei; Li, Cen; Jiang, Ye; Ren, Shu-Meng

    2010-10-29

    A simple sample preparation method was developed by using a centrifugal ultrafiltration (CF-UF) device with hollow fiber (HF) for the determination of cefaclor in plasma by HPLC. Samples were placed into a homemade device, which was consisted of a glass tube and a U-shaped hollow fiber. The filtrate was withdrawn from the hollow fiber into a syringe after centrifugation and 20 μL was directly injected into the HPLC for analysis. The HPLC method had a linear calibration curve in the concentration range of 6.00×10(-2)-30.7 μg mL(-1)(r=0.9996). The limit of detection (LOD) and limit of quantitation (LOQ) were 0.02 and 0.06 μg mL(-1), respectively. The intra and inter-day precisions (RSD) were 1.7%, 1.2%, 1.0% and 3.6%, 2.5%, 1.9%, respectively, for three concentrations. Assay accuracy was higher than 99.2% and the absolute recovery was 86.8-92.5%. It is feasible to use this novel and low cost device for sample pretreatment for the analysis of cefaclor in plasma.

  20. Colloidal Plasmas : Basic physics of colloidal plasmas

    Indian Academy of Sciences (India)

    C B Dwivedi

    2000-11-01

    Colloidal plasma is a distinct class of the impure plasmas with multispecies ionic composition. The distinction lies in the phase distribution of the impurity-ion species. The ability to tailor the electrostatic interactions between these colloidal particles provides a fertile ground for scientists to investigate the fundamental aspects of the Coulomb phase transition behavior. The present contribution will review the basic physics of the charging mechanism of the colloidal particles as well as the physics of the collective normal mode behavior of the general multi-ion species plasmas. Emphasis will be laid on the clarification of the prevailing confusing ideas about distinct qualities of the various acoustic modes, which are likely to exist in colloidal plasmas as well as in normal multi-ion species plasmas. Introductory ideas about the proposed physical models for the Coulomb phase transition in colloidal plasma will also be discussed.

  1. Porous membrane ultrafiltration-A novel method for enrichment of the active compounds from micro-plasma samples

    Science.gov (United States)

    Liu, Qingshan; Yin, Xiaoying; Sha, Biying; You, Jingjing

    2014-10-01

    To enrich the active compounds from plasma samples, a novel and simple method has been developed using a porous membrane envelope based on the ultrafiltration technique combining with high-performance liquid chromatography. The ultrafiltration device is a sealed porous membrane envelope prepared with a polypropylene sheet to effectively separate the active small molecules and large biomolecules, and a sample carrier is held inside the envelope to load plasma samples. The enrichment of hyperoside and isoquercitrin from rat plasma was used as an example. Significant factors of this method, such as membrane types, the desorption solvent, and the desorption time were optimized for the ultrafiltration method. Under the optimal conditions, correlation coefficients of 0.999 and 0.998 were obtained for hyperoside and isoquercitrin, respectively, with a linear range between 0.5 and 100 μg/mL. The absolute extraction recoveries from 83.2% to 86.8% were achieved. The detection limits of the method for hyperoside and isoquercitrin were 0.22 and 0.20 μg/mL, respectively. Compared with protein precipitation, solid-phase extraction and commercial ultrafiltration membrane methods, our proposed method demonstrates lower detection limits and lower cost for extraction. Also, it consumes less plasma samples and is found to be applicable to biological samples.

  2. Trace Elements Analysis of Geological Samples by Laser Ablation Inductively Coupled Plasma Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    This paper describes recent work applying a taser ablation system (LSX-200) hyphenated with POEMS Ⅲ inductively coupled plasma mass spectrometry (LA-ICP-MS) for the in situ analysis of 22 trace elements of solid geological materials. It demonstrates the potential of LA-ICP-MS for the determination of geochemically important trace and ultra-trace elements following XRF routine sample preparation. Signal drift, difference in transport efficiency and sampling yield are well corrected with NIST SRM 612 as external calibration standard and Ca as internal standard. The obtained results agree to the recommended values with relative error better than 15 % and RSD less than 15 % for most determined trace elemems. LOD ranges from 0.021 × 10-6 to 0. 23 × 10-6 and less than 0.10 × 10-6 for majority trace elements determined. In addition, home-made macro functions including filter and calculator compiled by VBA language under Excel software greatly enhanced off-line data reduction efficiency.``

  3. Nonlinear plasma wave in magnetized plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Bulanov, Sergei V. [Kansai Photon Science Institute, JAEA, Kizugawa, Kyoto 619-0215 (Japan); Prokhorov Institute of General Physics, Russian Academy of Sciences, Moscow 119991 (Russian Federation); Moscow Institute of Physics and Technology, Dolgoprudny, Moscow region 141700 (Russian Federation); Esirkepov, Timur Zh.; Kando, Masaki; Koga, James K. [Kansai Photon Science Institute, JAEA, Kizugawa, Kyoto 619-0215 (Japan); Hosokai, Tomonao; Zhidkov, Alexei G. [Photon Pioneers Center, Osaka University, 2-8 Yamadaoka, Suita, Osaka 565-0871 (Japan); Japan Science and Technology Agency, CREST, 2-1, Yamadaoka, Suita, Osaka 565-0871 (Japan); Kodama, Ryosuke [Photon Pioneers Center, Osaka University, 2-8 Yamadaoka, Suita, Osaka 565-0871 (Japan); Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan)

    2013-08-15

    Nonlinear axisymmetric cylindrical plasma oscillations in magnetized collisionless plasmas are a model for the electron fluid collapse on the axis behind an ultrashort relativisically intense laser pulse exciting a plasma wake wave. We present an analytical description of the strongly nonlinear oscillations showing that the magnetic field prevents closing of the cavity formed behind the laser pulse. This effect is demonstrated with 3D PIC simulations of the laser-plasma interaction. An analysis of the betatron oscillations of fast electrons in the presence of the magnetic field reveals a characteristic “Four-Ray Star” pattern.

  4. Elements of plasma technology

    CERN Document Server

    Wong, Chiow San

    2016-01-01

    This book presents some fundamental aspects of plasma technology that are important for beginners interested to start research in the area of plasma technology . These include the properties of plasma, methods of plasma generation and basic plasma diagnostic techniques. It also discusses several low cost plasma devices, including pulsed plasma sources such as plasma focus, pulsed capillary discharge, vacuum spark and exploding wire; as well as low temperature plasmas such as glow discharge and dielectric barrier discharge which the authors believe may have potential applications in industry. The treatments are experimental rather than theoretical, although some theoretical background is provided where appropriate. The principles of operation of these devices are also reviewed and discussed.

  5. Quantitative determination of fentanyl in newborn pig plasma and cerebrospinal fluid samples by HPLC-MS/MS.

    Science.gov (United States)

    Blanco, M E; Encinas, E; González, O; Rico, E; Vozmediano, V; Suárez, E; Alonso, R M

    2015-09-01

    In this study, a selective and sensitive high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method requiring low sample volume (≤100 μL) was developed and validated for the quantitative determination of the opioid drug fentanyl in plasma and cerebrospinal fluid (CSF). A protein precipitation extraction with acetonitrile was used for plasma samples whereas CSF samples were injected directly on the HPLC column. Fentanyl and (13) C6 -fentanyl (Internal Standard) were analyzed in an electrospray ionization source in positive mode, with multiple reaction monitoring (MRM) of the transitions m/z 337.0/188.0 and m/z 337.0/105.0 for quantification and confirmation of fentanyl, and m/z 343.0/188.0 for (13) C6 -fentanyl. The respective lowest limits of quantification for plasma and CSF were 0.2 and 0.25 ng/mL. Intra- and inter-assay precision and accuracy did not exceed 15%, in accordance with bioanalytical validation guidelines. The described analytical method was proven to be robust and was successfully applied to the determination of fentanyl in plasma and CSF samples from a pharmacokinetic and pharmacodynamic study in newborn piglets receiving intravenous fentanyl (5 µg/kg bolus immediately followed by a 90-min infusion of 3 µg/kg/h).

  6. A Comprehensive Software and Database Management System for Glomerular Filtration Rate Estimation by Radionuclide Plasma Sampling and Serum Creatinine Methods.

    Science.gov (United States)

    Jha, Ashish Kumar

    2015-01-01

    Glomerular filtration rate (GFR) estimation by plasma sampling method is considered as the gold standard. However, this method is not widely used because the complex technique and cumbersome calculations coupled with the lack of availability of user-friendly software. The routinely used Serum Creatinine method (SrCrM) of GFR estimation also requires the use of online calculators which cannot be used without internet access. We have developed user-friendly software "GFR estimation software" which gives the options to estimate GFR by plasma sampling method as well as SrCrM. We have used Microsoft Windows(®) as operating system and Visual Basic 6.0 as the front end and Microsoft Access(®) as database tool to develop this software. We have used Russell's formula for GFR calculation by plasma sampling method. GFR calculations using serum creatinine have been done using MIRD, Cockcroft-Gault method, Schwartz method, and Counahan-Barratt methods. The developed software is performing mathematical calculations correctly and is user-friendly. This software also enables storage and easy retrieval of the raw data, patient's information and calculated GFR for further processing and comparison. This is user-friendly software to calculate the GFR by various plasma sampling method and blood parameter. This software is also a good system for storing the raw and processed data for future analysis.

  7. Reviews of plasma physics

    CERN Document Server

    2008-01-01

    "Reviews of Plasma Physics Volume 24," edited by V.D. Shafranov, presents two reviews from the cutting-edge of Russian plasma physics research. The first review by V.A. Rozhansky devoted to the mechanisms of transverse conductivity and generation of self-consistent electric fields in strongly ionized magnetized plasma. The second review by O.G. Bakunin considers numerous aspects of turbulent transport in plasma and fluids. This review is focused on scaling arguments for describing anomalous diffusion in the presence of complex structures. These topics are especially important for fusion plasma research, plasma astrophysics, discharge physics, and turbulence

  8. Reviews of plasma physics

    Energy Technology Data Exchange (ETDEWEB)

    Shafranov, Vitalii Dmitrievich (ed.); Bakunin, Oleg G. (comps.) [Rossijskij Nauchnyj Tsentr ' ' Kurchatovskij Inst.' ' , Moscow (Russian Federation). Nuclear Fusion Inst.; Rozhansky, V. [St. Petersburg State Polytechnical Univ. (Russian Federation)

    2008-07-01

    Reviews of Plasma Physics Volume 24, edited by V.D. Shafranov, presents two reviews from the cutting-edge of Russian plasma physics research. The first review by V.A. Rozhansky devoted to the mechanisms of transverse conductivity and generation of self-consistent electric fields in strongly ionized magnetized plasma. The second review by O.G. Bakunin considers numerous aspects of turbulent transport in plasma and fluids. This review is focused on scaling arguments for describing anomalous diffusion in the presence of complex structures. These topics are especially important for fusion plasma research, plasma astrophysics, discharge physics, and turbulence (orig.)

  9. Reduction of acid effects on trace element determination in food samples by CH4 mixed plasma-DRC-MS.

    Science.gov (United States)

    Guo, Wei; Hu, Shenghong; Zhang, Jiangyi; Hu, Zhaochu; Zhang, Hongfei; Wang, Yanxin

    2012-03-15

    A robust method for trace element determination in food samples by addition of methane to the plasma of a dynamic reaction cell mass spectrometer (CH(4) mixed plasma-DRC-MS) was developed. Addition of 3 mL min(-1) methane to Ar-plasma eliminates the signal suppressions of various elements (As, Se, Hg, etc.) due to the high concentration of nitric acid (10%, v/v). The CH(4)-Ar mixed plasma may compensate for the plasma cooling effects due to the highly concentrated nitric acid. The interfering polyatomic ions (40)Ar(12)C(+), (40)Ar(35)Cl(+) and (40)Ar(40)Ar(+) on (52)Cr(+), (75)As(+) and (80)Se(+) determination were removed effectively using the DRC with CH(4) as the reaction gas. The limits of quantification (LOQ, 10σ) were 0.35 ng g(-1), 0.07 ng g(-1), 0.35 ng g(-1), 0.07 ng g(-1), 0.15 ng g(-1), and 0.07 ng g(-1) for As, Cd, Cr, Hg, Pb and Se, respectively. The proposed method was applied to the determination of these trace elements in four food standard reference materials (NIST1577b, GBW10018, NIST1570a and GBW10016), and the results were in good agreement with the certified values.

  10. Determination of stable cesium and strontium in rice samples by inductively coupled plasma mass spectrometry

    Science.gov (United States)

    Srinuttrakul, W.; Yoshida, S.

    2017-06-01

    For long-term radiation dose assessment models, food ingestion is one of the major exposure pathways to human. In general, the stable isotopes can serve as analogues of radioisotopes. In this study, rice samples were collected from 30 paddy fields in Si Sa Ket, Yasothon and Roi Et in the northeast of Thailand in November 2014. The concentrations of stable cesium (Cs-133) and strontium (Sr-88) in polished rice were determined by inductively coupled plasma mass spectrometry (ICP-MS). The standard reference material of rice flour (NIST 1568a) with spiked Cs and Sr was used to validate the analytical method. The concentration of Cs in polished rice from Si Sa Ket, Yasothon and Roi Et was 0.158 ± 0.167 mg kg-1, 0.090 ± 0.117 mg kg-1 and 0.054 ± 0.031 mg kg-1, respectively. The concentration of Sr in polished rice from Si Sa Ket, Yasothon and Roi Et was 0.351 ± 0.108 mg kg-1, 0.364 ± 0.215 mg kg-1 and 0.287 ± 0.102 mg kg-1, respectively. Comparison of the results with Japanese data before the Fukushima Di-ichi nuclear power plant accident showed that the concentrations of both Cs and Sr for Thai rice were higher than those for Japanese rice.

  11. Heat Transfer in the Anode Region in Plasma-Electrolytic Heating of a Cylindrical Sample

    Science.gov (United States)

    Zhirov, A. V.; Belkin, P. N.; Shadrin, S. Yu.

    2017-07-01

    The energy balance in a three-phase system "anode-vapor/gas envelope-electrolyte" and the results of experimental determination of the heat fluxes acting in the vapor-gas envelope are considered. To determine the fluxes quantitatively, the calorimetric method and the theory of inverse problems of the thermal conductivity of solid bodies are used. It is shown that heat fluxes into the anode and electrolyte increase with the voltage delivered to the electrochemical cell, whereas the heat flux associated with the vapor release to the atmosphere remains practically unchanged. An increase in the concentration of the current-conducting component in the electrolyte leads to a certain growth of the heat flux into the anode and to a decrease of the flux into the electrolyte. The stages of a nonstationary period of the process of plasma-electrolytic heating have been revealed, and it has been established that the time of heating the vapor-gas envelope is several times shorter than the time of heating a sample.

  12. Use of factorial design for evaluation of plasma conditions and comparison of two liquid sample introduction systems for an axially viewed inductively coupled plasma optical emission spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Trevizan, Lilian C. [Grupo de Analise Instrumental Aplicada, Departamento de Quimica, Universidade Federal de Sao Carlos, Caixa Postal 676, Sao Carlos, SP, 13650-970 (Brazil); Vieira, Edivan C. [Grupo de Analise Instrumental Aplicada, Departamento de Quimica, Universidade Federal de Sao Carlos, Caixa Postal 676, Sao Carlos, SP, 13650-970 (Brazil); Embrapa Pecuaria Sudeste, Sao Carlos, SP (Brazil); Nogueira, Ana Rita A. [Embrapa Pecuaria Sudeste, Sao Carlos, SP (Brazil); Nobrega, Joaquim A. [Grupo de Analise Instrumental Aplicada, Departamento de Quimica, Universidade Federal de Sao Carlos, Caixa Postal 676, Sao Carlos, SP, 13650-970 (Brazil)]. E-mail: djan@terra.com.br

    2005-06-30

    A factorial design was applied to evaluate plasma conditions employing the Mg II 280/Mg I 285 nm intensity ratio in an axially viewed inductively coupled plasma optical emission spectrometer using different sample introduction devices: a concentric or a V-groove nebulizer and a cyclonic or a Sturman-Masters spray chamber. Effects of nebulizer gas flow-rate on Mg II/Mg I ratio were different in each introduction system. Robust conditions were obtained at low nebulizer gas flow-rate when using concentric nebulizer with a cyclonic spray chamber or a concentric nebulizer and a Sturman-Masters spray chamber. However, when using a V-groove nebulizer with a Sturman-Masters spray chamber, Mg II/Mg I ratio increased at high nebulizer gas flow-rates. Recovery experiments for a milk standard reference material diluted in water-soluble tertiary amines in both robust and non-robust conditions indicated that the robust condition was reached at higher nebulizer gas flow-rates and led to better accuracy and precision when using a V-groove nebulizer.

  13. Hot plasma dielectric tensor

    NARCIS (Netherlands)

    Westerhof, E.

    1996-01-01

    The hot plasma dielectric tensor is discussed in its various approximations. Collisionless cyclotron resonant damping and ion/electron Bernstein waves are discussed to exemplify the significance of a kinetic description of plasma waves.

  14. Special issue: Plasma Conversion

    NARCIS (Netherlands)

    Nozaki, T.; Bogaerts, A.; Tu, X.; van de Sanden, M. C. M.

    2017-01-01

    With growing concern of energy and environmental issues, the combination of plasma and heterogeneous catalysts receives special attention in greenhouse gas conversion, nitrogen fixation and hydrocarbon chemistry. Plasma gas conversion driven by renewable electricity is particularly important for the

  15. Evaluation of chemiluminescence method for the analysis of plasma homocysteine and comparison with HPLC method in children samples

    OpenAIRE

    Thais Moura Gascón; Fernanda Schindler; Claudia Giorgia Bronzatti de Oliveira; Fabiola Isabel Suano Souza; Sonia Hix; Roseli Oselka Sacardo Sarni; Ana Paula Arantes Bacan; Vania D’Almeida; Auro del Giglio; Fernando Luiz Affonso Fonseca

    2010-01-01

    ABSTRACT Objective: To compare the results for homocysteine concentration using chemiluminescence and HPLC methods in samples from school-age children. In addition, to determine the reference values for patients of this age group and assess the real prognostic value of homocysteine in healthy children. Methods: A prospective observational study was undertaken to determine plasma levels of homocysteine using two different assays, HPLC and chemiluminescence, in 185 samples from school-age chi...

  16. Microwave Argon Plasma Torch

    Science.gov (United States)

    2013-07-01

    an electron-ion pair in the discharge. Fig. 2. EEDF is non - Maxwellian and changes along the plasma column The electron–neutral collision...plasma radius. Even at atmospheric pressure the EEDF is non - Maxwellian and it is changing along the plasma column. ...18 31st ICPIG, July 14-19, 2013, Granada, Spain EEDF usually strongly differs from Maxwellian and chages along the plasma column (this is

  17. Introduction to Plasma Physics

    Science.gov (United States)

    Gurnett, Donald A.; Bhattacharjee, Amitava

    2017-03-01

    Preface; 1. Introduction; 2. Characteristic parameters of a plasma; 3. Single particle motions; 4. Waves in a cold plasma; 5. Kinetic theory and the moment equations; 6. Magnetohydrodynamics; 7. MHD equilibria and stability; 8. Discontinuities and shock waves; 9. Electrostatic waves in a hot unmagnetized plasma; 10. Waves in a hot magnetized plasma; 11. Nonlinear effects; 12. Collisional processes; Appendix A. Symbols; Appendix B. Useful trigonometric identities; Appendix C. Vector differential operators; Appendix D. Vector calculus identities; Index.

  18. Plasma physics an introduction

    CERN Document Server

    Fitzpatrick, Richard

    2014-01-01

    Plasma Physics: An Introduction is based on a series of university course lectures by a leading name in the field, and thoroughly covers the physics of the fourth state of matter. This book looks at non-relativistic, fully ionized, nondegenerate, quasi-neutral, and weakly coupled plasma. Intended for the student market, the text provides a concise and cohesive introduction to plasma physics theory, and offers a solid foundation for students wishing to take higher level courses in plasma physics.

  19. Post-operative corticosterone levels in plasma and feces of mice subjected to permanent catheterization and automated blood sampling.

    Science.gov (United States)

    Sundbom, Renée; Jacobsen, Kirsten R; Kalliokoski, Otto; Hau, Jann; Abelson, Klas S P

    2011-01-01

    This study investigated the effects of surgical placement of permanent arterial catheters on plasma corticosterone levels, fecal corticosterone excretion and body weight in male BALB/c/Sca mice. In addition, the effects of voluntarily ingested buprenorphine in doses of 0.5 and 1.0 mg/kg body weight on these parameters were studied. A catheter was placed in the carotid artery during isoflurane anesthesia. Immediately after surgery, the mice were connected to an AccuSampler® μ and blood samples for plasma corticosterone quantification were collected automatically during the first 24 h postoperatively. All fecal boli produced 24 h before and 24 h after surgery were collected for fecal corticosterone excretion measures and the pre- and post-operative body weights were registered. Plasma corticosterone levels were in the range of 150-300 ng/ml after the surgical procedure and the body weight was significantly lower 24 h after surgery compared to its pre-operative value. Contrary to what was expected, the total fecal corticosterone excretion was significantly reduced 24 h after surgery, as was the defecation. Buprenorphine treatment significantly lowered the plasma corticosterone levels, but had no effect on fecal corticosterone excretion or body weight change. It was concluded that surgical placement of an arterial catheter induces a significant stress response, as judged by its effect on plasma corticosterone and body weight. Voluntary ingestion of buprenorphine improved postoperative recovery by lowering plasma corticosterone concentrations. Neither fecal corticosterone excretion nor body weight change seems suitable for postoperative stress assessment in mice in the present experimental setup.

  20. Plasma membrane ATPases

    DEFF Research Database (Denmark)

    Palmgren, Michael Broberg; Bækgaard, Lone; Lopez Marques, Rosa Laura

    2011-01-01

    The plasma membrane separates the cellular contents from the surrounding environment. Nutrients must enter through the plasma membrane in order to reach the cell interior, and toxic metabolites and several ions leave the cell by traveling across the same barrier. Biological pumps in the plasma me...

  1. Plasma in dentistry

    OpenAIRE

    Cha, Seunghee; Park, Young-Seok

    2014-01-01

    This review describes the contemporary aspects of plasma application in dentistry. Previous studies on plasma applications were classified into two categories, surface treatment and direct applications, and were reviewed, respectively according to the approach. The current review discussed modification of dental implant surface, enhancing of adhesive qualities, enhancing of polymerization, surface coating and plasma cleaning under the topics of surface treatment. Microbicidal activities, deco...

  2. The Plasma Universe

    Science.gov (United States)

    Suplee, Curt

    2009-09-01

    Preface; 1. The fourth state of matter; 2. The music and dance of plasmas; 3. The Sun-Earth connection; 4. Bringing the Sun to Earth: the story of controlled thermonuclear fusion; 5. The cosmic plasma theater: galaxies, stars, and accretion disks; 6. Putting plasmas to work; Index.

  3. Psychotropics and weak opioid analgesics in plasma samples of older hip fracture patients - detection frequencies and consistency with drug records.

    Science.gov (United States)

    Waade, Ragnhild Birkeland; Molden, Espen; Martinsen, Mette Irene; Hermann, Monica; Ranhoff, Anette Hylen

    2017-07-01

    To determine use of psychotropic drugs and weak opioids in hip fracture patients by analysing plasma samples at admission, and compare detected drug frequencies with prescription registry data and drug records. Plasma from 250 hip fracture patients aged ≥65 years sampled at hospital admission were analysed by ultra-performance liquid chromatography-tandem mass spectrometry methods for detection of psychotropic drugs and weak opioid analgesics (alcohol also determined). Odds ratios for drugs detected in plasma of hip fracture patients vs. prescription frequencies of the same drugs in an age-, time- and region-matched reference population were calculated. Moreover, recorded and measured drugs were compared. Psychotropic drugs and/or weak opioid analgesics were detected in 158 (63%) of the patients (median age 84 years; 76% females), while alcohol was found in 19 patients (7.6%). The occurrence of diazepam (odds ratio 1.6; 95% confidence interval 1.1-2.4), nitrazepam (2.3; 1.3-4.1), selective serotonin reuptake inhibitors (1.9; 1.3-2.9) and mirtazapine (2.3; 1.2-4.3) was significantly higher in plasma samples of hip fracture patients than in prescription data from the reference population. Poor consistency between recorded and measured drugs was disclosed for z-hypnotics and benzodiazepines; e.g. diazepam was detected in 29 (11.6%), but only recorded in six (2.4%) of the patients. Plasma analysis shows that use of antidepressants and benzodiazepines in hip fracture patients is significantly more frequent than respective prescription frequencies in the general elderly population. Moreover, consistency between recorded and actual use of psychotropic fall-risk drugs is poor at hospital admission of hip fracture patients. © 2017 The British Pharmacological Society.

  4. New high temperature plasmas and sample introduction systems for analytical atomic emission and mass spectrometry. Progress report, January 1, 1990--December 31, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Montaser, A.

    1992-09-01

    New high temperature plasmas and new sample introduction systems are explored for rapid elemental and isotopic analysis of gases, solutions, and solids using mass spectrometry and atomic emission spectrometry. Emphasis was placed on atmospheric pressure He inductively coupled plasmas (ICP) suitable for atomization, excitation, and ionization of elements; simulation and computer modeling of plasma sources with potential for use in spectrochemical analysis; spectroscopic imaging and diagnostic studies of high temperature plasmas, particularly He ICP discharges; and development of new, low-cost sample introduction systems, and examination of techniques for probing the aerosols over a wide range. Refs., 14 figs. (DLC)

  5. Development of a highly specific enzyme immunoassay for oxytocin and its use in plasma samples.

    Science.gov (United States)

    Haraya, Shiomi; Karasawa, Koji; Sano, Yoshihiro; Ozawa, Kimiko; Kato, Nobumasa; Arakawa, Hidetoshi

    2017-01-01

    Background The peptide hormone oxytocin acts in the central nervous system and plays an important role in various complex social behaviours. We report the production of a high affinity and specificity antibody for oxytocin and its use in a highly sensitive enzyme immunoassay. Biotin that was chemically bound to oxytocin derivative containing zero to six lysines as bridge was the labelled antigen. Seven labelled antigens were used to develop a highly sensitive enzyme immunoassay. Methods Antioxytocin antiserum was obtained by immunization of oxytocin-bovine thyrogloblin conjugate to rabbit. Oxytocin sample was added to the second antibody-coated microtitre plate and allowed to react overnight at 4℃, then biotinylated oxytocin was added 1 h at 4℃, and horseradish peroxidase-labelled avidin was added and incubated for 1 h at room temperature. The plate was then washed. Horseradish peroxidase activity was measured by a colorimetric method using o-phenylenediamine (490 nm). Results The sensitivity of the enzyme immunoassay improved as the number of lysine residues increased; consequently, biotinylated oxytocin bridged with five lysines was used. A standard curve for oxytocin ranged from 1.0 to 1000 pg/assay. The detection limit of the assay was 2.36 pg, and the reproducibility was 3.6% as CV% ( n = 6). Cross-reactivity with vasopressin and vasotocin was less than 0.01%. Conclusion The sensitivity of the enzyme immunoassay could be improved by increasing the number of lysine residues on the biotin-labelled antigen. The proposed method is sensitive and more specific than conventional immunoassays for oxytocin and can be used to determine plasma oxytocin concentrations.

  6. Cyclotron waves in plasma

    CERN Document Server

    Lominadze, D G

    2013-01-01

    Cyclotron Waves in Plasma is a four-chapter text that covers the basic physical concepts of the theory of cyclotron waves and cyclotron instabilities, brought about by the existence of steady or alternating plasma currents flowing perpendicular to the magnetic field.This book considers first a wide range of questions associated with the linear theory of cyclotron oscillations in equilibrium plasmas and in electron plasmas in metals and semiconductors. The next chapter deals with the parametric excitation of electron cyclotron oscillations in plasma in an alternating electric field. A chapter f

  7. Plasma Therapy: An Overview

    Directory of Open Access Journals (Sweden)

    Rajkumar Diwan

    2011-01-01

    Full Text Available Definition: Plasma, the fourth state of matter, is a collection of charged particles (electrons, ions, neutral atoms. Recent demonstration of plasma technology in treatment of living cells, tissue and organs are creating a new field at the intersection of plasma science and technology with biology and medicine known as plasma medicine. Plasma medicine is one of the newest fields of modem applied plasma chemistry. It appeared several years ago and comprises studies concerning the direct action of low-temperature, one atmosphere air plasma (cold plasma/nonthermal plasmalnonequilibrium on body tissues for various noninvasive therapeutic treatments or diagnostics purpose. The study of plasma holds promise for a myriad of applications ranging from lasers and electronics, hazardous decontamination, sterilization and disinfection of foods, soil, water, instruments, to medical uses in wound healing and treating certain types of tumors and cancers. Plasma represents a new state-of-the-art sterilization and disinfection treatment for certain oral and environmental pathogens, heat-sensitive materials, hard and soft surfaces, and may assist health care facilities in the management of various health concerns. The role that low temperature atmospheric pressure plasma (LTAPP could play in the inactivation of pathogenic microorganisms might prove to be a new, faster, more economical alternative.

  8. Method of Electrolyte-Plasma Surface Hardening of 65G and 20GL Low-Alloy Steels Samples

    Science.gov (United States)

    Rakhadilov, Bauyrzhan; Zhurerova, Laila; Pavlov, Alexander

    2016-08-01

    This work is devoted to formation of modified surface layers in 65G and 20GL steels which using for the manufacture of railway transport parts, as well as the study of influence of the parametersof electrolyte-plasma surface hardening methodon the changes in structural-phase states, improving of wear-resistance. The process of electrolyte-plasma surface hardening of 65G and 20GL steels samples conducted in the electrolyte from water solution of 20% sodium carbonate, in the mode ~850°C - 2 seconds, ∼⃒1200°C - 3 seconds. It is established that in the initial state 20GL steel has ferrite-pearlite structure, and the 60G steel consists of pearlite and cement structure. After application of electrolyte-plasma surface hardening is observed the formation of carbides particles and martensite phase components in the structure of 20GL and 60G steels. It is determined that after electrolyte-plasma surface hardening with heating time - 2 seconds, the abrasive wear-resistance of 65G and 20GL steels increased to 1.3 times and 1.2 times, respectively, and the microhardness is increased to 1.6 times and 1.3 times, respectively.

  9. Rapid determination of piracetam in human plasma and cerebrospinal fluid by micellar electrokinetic chromatography with sample direct injection.

    Science.gov (United States)

    Yeh, Hsin-Hua; Yang, Yuan-Han; Ko, Ju-Yun; Chen, Su-Hwei

    2006-07-07

    A simple micellar electrokinetic chromatography (MEKC) method with UV detection at 200 nm for analysis of piracetam in plasma and in cerebrospinal fluid (CSF) by direct injection without any sample pretreatment is described. The separation of piracetam from biological matrix was performed at 25 degrees C using a background electrolyte consisting of Tris buffer with sodium dodecyl sulfate (SDS) as the electrolyte solution. Several parameters affecting the separation of the drug from biological matrix were studied, including the pH and concentrations of the Tris buffer and SDS. Under optimal MEKC condition, good separation with high efficiency and short analyses time is achieved. Using imidazole as an internal standard (IS), the linear ranges of the method for the determination of piracetam in plasma and in CSF were all between 5 and 500 microg/mL; the detection limit of the drug in plasma and in CSF (signal-to-noise ratio=3; injection 0.5 psi, 5s) was 1.0 microg/mL. The applicability of the proposed method for determination of piracetam in plasma and CSF collected after intravenous administration of 3g piracetam every 6h and oral administration 1.2g every 6h in encephalopathy patients with aphasia was demonstrated.

  10. Arc Plasma Torch Modeling

    CERN Document Server

    Trelles, J P; Vardelle, A; Heberlein, J V R

    2013-01-01

    Arc plasma torches are the primary components of various industrial thermal plasma processes involving plasma spraying, metal cutting and welding, thermal plasma CVD, metal melting and remelting, waste treatment and gas production. They are relatively simple devices whose operation implies intricate thermal, chemical, electrical, and fluid dynamics phenomena. Modeling may be used as a means to better understand the physical processes involved in their operation. This paper presents an overview of the main aspects involved in the modeling of DC arc plasma torches: the mathematical models including thermodynamic and chemical non-equilibrium models, turbulent and radiative transport, thermodynamic and transport property calculation, boundary conditions and arc reattachment models. It focuses on the conventional plasma torches used for plasma spraying that include a hot-cathode and a nozzle anode.

  11. Laminar Plasma Dynamos

    CERN Document Server

    Wang, Z; Barnes, C W; Barnes, D C; Wang, Zhehui; Pariev, Vladimir I.; Barnes, Cris W.; Barnes, Daniel C.

    2002-01-01

    A new kind of dynamo utilizing flowing laboratory plasmas has been identified. Conversion of plasma kinetic energy to magnetic energy is verified numerically by kinematic dynamo simulations for magnetic Reynolds numbers above 210. As opposed to intrinsically-turbulent liquid-sodium dynamos, the proposed plasma dynamos correspond to laminar flow topology. Modest plasma parameters, 1-20 eV temperatures, 10^{19}-10^{20} m^{-3} densities in 0.3-1.0 m scale-lengths driven by velocities on the order of the Alfven Critical Ionization Velocity (CIV), self-consistently satisfy the conditions needed for the magnetic field amplication. Growth rates for the plasma dynamos are obtained numerically with different geometry and magnetic Reynolds numbers. Magnetic-field-free coaxial plasma guns can be used to sustain the plasma flow and the dynamo.

  12. Plasma polymerization by Softplasma

    DEFF Research Database (Denmark)

    Jiang, J.; Wu, Zhenning; Benter, Maike

    2008-01-01

    In the late 19th century, the first depositions - known today as plasma polymers, were reported. In the last century, more and more research has been put into plasma polymers. Many different deposition systems have been developed. [1, 2] Shi F. F. broadly classified them into internal electrode......, external electrode, and electrodeless microwave or high frequency reactors. [3] Softplasma™ is an internal electrode plasma setup powered by low frequenc~ gower supply. It was developed in late 90s for surface treatment of silicone rubber. [ ]- 5] It is a low pressure, low electron density, 3D homogenous...... plasma. In this study, we are presenting the surface modification"pf polymers by plasma polymerization using Softplasma™. Softplasma™ can be used for two major types of polymerization: polymerization of vinyl monomers, where plasma acts as initiator; chemical vapour deposition, where plasma acts...

  13. Plasmas for medicine

    Science.gov (United States)

    von Woedtke, Th.; Reuter, S.; Masur, K.; Weltmann, K.-D.

    2013-09-01

    Plasma medicine is an innovative and emerging field combining plasma physics, life science and clinical medicine. In a more general perspective, medical application of physical plasma can be subdivided into two principal approaches. (i) “Indirect” use of plasma-based or plasma-supplemented techniques to treat surfaces, materials or devices to realize specific qualities for subsequent special medical applications, and (ii) application of physical plasma on or in the human (or animal) body to realize therapeutic effects based on direct interaction of plasma with living tissue. The field of plasma applications for the treatment of medical materials or devices is intensively researched and partially well established for several years. However, plasma medicine in the sense of its actual definition as a new field of research focuses on the use of plasma technology in the treatment of living cells, tissues, and organs. Therefore, the aim of the new research field of plasma medicine is the exploitation of a much more differentiated interaction of specific plasma components with specific structural as well as functional elements or functionalities of living cells. This interaction can possibly lead either to stimulation or inhibition of cellular function and be finally used for therapeutic purposes. During recent years a broad spectrum of different plasma sources with various names dedicated for biomedical applications has been reported. So far, research activities were mainly focused on barrier discharges and plasma jets working at atmospheric pressure. Most efforts to realize plasma application directly on or in the human (or animal) body for medical purposes is concentrated on the broad field of dermatology including wound healing, but also includes cancer treatment, endoscopy, or dentistry. Despite the fact that the field of plasma medicine is very young and until now mostly in an empirical stage of development yet, there are first indicators of its enormous

  14. Nonlinear Plasma Wave in Magnetized Plasmas

    CERN Document Server

    Bulanov, Sergei V; Kando, Masaki; Koga, James K; Hosokai, Tomonao; Zhidkov, Alexei G; Kodama, Ryosuke

    2013-01-01

    Nonlinear axisymmetric cylindrical plasma oscillations in magnetized collisionless plasmas are a model for the electron fluid collapse on the axis behind an ultrashort relativisically intense laser pulse exciting a plasma wake wave. We present an analytical description of the strongly nonlinear oscillations showing that the magnetic field prevents closing of the cavity formed behind the laser pulse. This effect is demonstrated with 3D PIC simulations of the laser-plasma interaction. An analysis of the betatron oscillations of fast electrons in the presence of the magnetic field reveals a characteristic "Four-Ray Star" pattern which has been observed in the image of the electron bunch in experiments [T. Hosokai, et al., Phys. Rev. Lett. 97, 075004 (2006)].

  15. Quartz crystal microbalance for the cardiac markers/antibodies binding kinetic measurements in the plasma samples

    Science.gov (United States)

    Agafonova, L. E.; Shumyantseva, V. V.; Archakov, A. I.

    2014-06-01

    The quartz crystal microbalance (QCM) was exploited for cardiac markers detection and kinetic studies of immunochemical reaction of cardiac troponin I (cTnI) and human heart fatty acid binding protein (H-FABP) with the corresponding monoclonal antibodies in undiluted plasma (serum) and standard solutions. The QCM technique allowed to dynamically monitor the kinetic differences in specific interactions and nonspecific sorption, without multiple labeling procedures and separation steps. The affinity binding process was characterized by the association (ka) and the dissociation (kd) kinetic constants and the equilibrium association (K) constant, all of which were obtained from experimental data.

  16. Biocompatibility of plasma nanostructured biopolymers

    Energy Technology Data Exchange (ETDEWEB)

    Slepičková Kasálková, N. [Department of Solid State Engineering, Institute of Chemical Technology, 166 28 Prague (Czech Republic); Slepička, P., E-mail: petr.slepicka@vscht.cz [Department of Solid State Engineering, Institute of Chemical Technology, 166 28 Prague (Czech Republic); Bačáková, L. [Institute of Physiology, Academy of Sciences of the Czech Republic 142 20 Prague (Czech Republic); Sajdl, P. [Department of Power Engineering, Institute of Chemical Technology, 166 28 Prague (Czech Republic); Švorčík, V. [Department of Solid State Engineering, Institute of Chemical Technology, 166 28 Prague (Czech Republic)

    2013-07-15

    Many areas of medicine such as tissue engineering requires not only mastery of modification techniques but also thorough knowledge of the interaction of cells with solid state substrates. Plasma treatment can be used to effective modification, nanostructuring and therefore can significantly change properties of materials. In this work the biocompatibility of the plasma nanostructured biopolymers substrates was studied. Changes in surface chemical structure were studied by X-ray photoelectron spectroscopy (XPS). The morphology pristine and modified samples were determined using atomic force microscopy (AFM). The surface wettability was determined by goniometry from contact angle. Biocompatibility was determined by in vitro tests, the rat vascular smooth muscle cells (VSMCs) were cultivated on the pristine and plasma modified biopolymer substrates. Their adhesion, proliferation, spreading and homogeneous distribution on polymers was monitored. It was found that the plasma treatment leads to rapid decrease of contact angle for all samples. Contact angle decreased with increasing time of modification. XPS measurements showed that plasma treatment leads to changes in ratio of polar and non-polar groups. Plasma modification was accompanied by a change of surface morphology. Biological tests found that plasma treatment have positive effect on cells adhesion and proliferation cells and affects the size of cell’s adhesion area. Changes in plasma power or in exposure time influences the number of adhered and proliferated cells and their distribution on biopolymer surface.

  17. Simulated Irradiation of Samples in HFIR for use as Possible Test Materials in the MPEX (Material Plasma Exposure Experiment) Facility

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, Ronald James [ORNL; Rapp, Juergen [ORNL

    2014-01-01

    The importance of Plasma Material Interaction (PMI) is a major concern in fusion reactor design and analysis. The Material-Plasma Exposure eXperiment (MPEX) facility will explore PMI under fusion reactor plasma conditions. Samples with accumulated displacements per atom (DPA) damage produced by irradiations in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) will be studied in the MPEX facility. The project presented in this paper involved performing assessments of the induced radioactivity and resulting radiation fields of a variety of potential fusion reactor materials. The scientific code packages MCNP and SCALE were used to simulate irradiation of the samples in HFIR; generation and depletion of nuclides in the material and the subsequent composition, activity levels, gamma radiation fields, and resultant dose rates as a function of cooling time. These state-of-the-art simulation methods were used in addressing the challenge of the MPEX project to minimize the radioactive inventory in the preparation of the samples for inclusion in the MPEX facility.

  18. Plasma Biomedicine in Orthopedics

    Science.gov (United States)

    Hamaguchi, Satsohi

    2012-10-01

    Various effects of plasmas irradiation on cells, tissues, and biomaterials relevant for orthopedic applications have been examined. For direct application of plasmas to living cells or tissues, dielectric barrier discharges (DBDs) with helium flows into ambient air were used. For biomaterial processing, on the other hand, either helium DBDs mentioned above or low-pressure discharges generated in a chamber were used. In this presentation, plasma effects on cell proliferation and plasma treatment for artificial bones will be discussed. First, the conditions for enhanced cell proliferation in vitro by plasma applications have been examined. The discharge conditions for cell proliferation depend sensitively on cell types. Since cell proliferation can be enhanced even when the cells are cultured in a plasma pre-treated medium, long-life reactive species generated in the medium by plasma application or large molecules (such as proteins) in the medium modified by the plasma are likely to be the cause of cell proliferation. It has been found that there is strong correlation between (organic) hydroperoxide generation and cell proliferation. Second, effects of plasma-treated artificial bones made of porous hydroxyapatite (HA) have been examined in vitro and vivo. It has been found that plasma treatment increases hydrophilicity of the surfaces of microscopic inner pores, which directly or indirectly promotes differentiation of mesenchymal stem cells introduced into the pores and therefore causes faster bone growth. The work has been performed in collaboration with Prof. H. Yoshikawa and his group members at the School of Medicine, Osaka University.

  19. Plasma detachment in linear devices

    Science.gov (United States)

    Ohno, N.

    2017-03-01

    Plasma detachment research in linear devices, sometimes called divertor plasma simulators, is reviewed. Pioneering works exploring the concept of plasma detachment were conducted in linear devices. Linear devices have contributed greatly to the basic understanding of plasma detachment such as volume plasma recombination processes, detached plasma structure associated with particle and energy transport, and other related issues including enhancement of convective plasma transport, dynamic response of plasma detachment, plasma flow reversal, and magnetic field effect. The importance of plasma detachment research using linear devices will be highlighted aimed at the design of future DEMO.

  20. Advanced plasma diagnostics for plasma processing

    Science.gov (United States)

    Malyshev, Mikhail Victorovich

    1999-10-01

    A new, non-intrusive, non-perturbing diagnostic method was developed that can be broadly applied to low pressure, weakly ionized plasmas and glow discharges-trace rare gases optical emission spectroscopy (TRG-OES). The method is based on a comparison of intensities of atomic emission from trace amounts of inert gases (He, Ne, Ar, Kr, and Xe) that are added to the discharge to intensities calculated from the theoretical model. The model assumes a Maxwellian electron energy distribution function (EEDF), computes the population of emitting levels both from the ground state and the metastable states of rare gases, and from the best fit between theory and experiment determines electron temperature (Te). Subject to conditions, TRG-OES can also yield electron density or its upper or lower limit. From the comparison of the emission from levels excited predominantly by high energy electrons to that excited by low energy electrons, information about the EEDF can be obtained. The use of TRG-OES also allows a traditionally qualitative actinometry technique (determination of concentration of radical species in plasma through optical emission) to become a precise quantitative method by including Te and rare gases metastables effects. A combination of TRG-OES, advanced actinometry, and Langmuir probe measurements was applied to several different plasma reactors and regimes of operation. Te measurements and experiments to correct excitation cross section were conducted in a laboratory helical resonator. Two chamber configuration of a commercial (Lam Research) metal etcher were studied to determine the effects of plasma parameters on plasma-induced damage. Two different methods (RF inductive coupling and ultra-high frequency coupling) for generating a plasma in a prototype reactor were also studied. Pulsed plasmas, a potential candidate to eliminate the plasma-induced damage to microelectronics devices that occurs in manufacturing due to differential charging of the wafer, have

  1. Thallium Analysis in Environmental Samples by Inductively Coupled Plasma Mass Spectrometry; Analisis de Talio en Muestras Ambientales por Espectrometria de Masas con Fuente de Plasma de Acoplamiento Inductivo

    Energy Technology Data Exchange (ETDEWEB)

    Higueras, I.; Fernandez, M.; Conde, E.; Gajate, A.

    2008-08-06

    Due to its high toxicity, thallium has been considered by the US Environmental Protection Agency as one of the priority pollutants to be controlled. While being a highly toxic element, thallium has been studied to a much lesser degree than other toxic elements, mainly because thallium is often undetected by classical analytical methods. Thallium is a rare and dispersed element that occurs mainly in sulfur-containing ores. Thus, it is a potential pollutant to surrounding environment, if Tl-rich mineral and/or their industrial wastes are not properly disposed. In this work an Inductively Coupled Plasma Mass Spectrometry analytical procedure has been developed in order to determine thallium in environmental solid samples and its application to the study of this element as a potential pollutant associated with natural and anthropogenic activities. The analytical procedure has been validated by the use of appropriate reference materials, and through the isotope dilution technique as a primary method of measurement. Finally, the developed procedure has been applied to several samples from a mining area, as one of the scenarios where thallium it is likely to occur. (Author) 87 refs.

  2. Plasma diagnostics and plasma-surface interactions in inductively coupled plasmas

    Science.gov (United States)

    Titus, Monica Joy

    square root of the plasma density at the plasma-sheath interface, one-fourth root of the electron temperature, and one-fourth root of the RF bias voltage under conditions where the sheath is predominantly capacitive. When the sheath impedance becomes increasingly resistive, the sensor measurements deviate from the scaling law and tend to be directly proportional to the plasma density. Vacuum ultraviolet (VUV) emissions in Ar ICPs are characterized and the chemical and physical modifications to 193 nm photoresist (PR) polymer materials processed in Ar ICPs are investigated. Fourier transform infrared (FTIR) transmission measurements as a function of VUV photon fluence demonstrate that VUV-induced bond breaking occurs over a period of time. A numerical model demonstrates that VUV photons deplete near-surface O-containing bonds, leading to deeper, subsequent penetration and more bond losses, while the remaining near-surface C--C bonds absorb the incident radiation and slow VUV photon penetration. The roughening mechanism of blanket and patterned 193 nm PR samples are explored in a well characterized Ar ICP. FTIR and atomic force microscopy (AFM) analysis of plasma processed 193 nm PR suggests that ion-induced generation of a graphitized layer at high energies, combined with VUV bulk modification of 193 nm PR may initiate PR roughening. The roughness of blanket samples increases as a function of VUV fluence, ion energy, and substrate temperature. Line width roughness (LWR) measurements of patterned samples demonstrate a similar trend suggesting that LWR may correlate with surface roughness of patterns. The results are compared to PR studies previously conducted in an ultra-high vacuum beam system demonstrating that the vacuum beam system is a useful tool that can deconvolute and simplify complex plasma systems.

  3. Pulsed plasma arc cladding

    Institute of Scientific and Technical Information of China (English)

    龙; 白钢; 李振民; 张赋升; 杨思乾

    2004-01-01

    A prototype of Pulsed Plasma Arc Cladding system was developed, in which single power source supplies both transferred plasma arc (TPA) and non-transferred plasma arc (N-TPA). Both plasmas work in turn in a high frequency controlled by an IGBT connecting nozzle and workpiece. The working frequency of IGBT ranges from 50 ~ 7000Hz, in which the plasmas can work in turn smoothly. Higher than 500 Hz of working frequency is suggested for promotion of cladding quality and protection of IGBT. Drag phenomenon of TPA intensifies as the frequency goes up, which tends to increase the current proportion of TPA and suppress N-TPA. The occupation ratio of IGBT can be regulated from 5% ~ 95%, which balances the power supplies of both plasmas. An occupation ratio higher than 50% gives adequate proportion of arc current for N-TPA to preheat powder.

  4. Introduction to Complex Plasmas

    CERN Document Server

    Bonitz, Michael; Ludwig, Patrick

    2010-01-01

    Complex plasmas differ from traditional plasmas in many ways: these are low-temperature high pressure systems containing nanometer to micrometer size particles which may be highly charged and strongly interacting. The particles may be chemically reacting or be in contact with solid surfaces, and the electrons may show quantum behaviour. These interesting properties have led to many applications of complex plasmas in technology, medicine and science. Yet complex plasmas are extremely complicated, both experimentally and theoretically, and require a variety of new approaches which go beyond standard plasma physics courses. This book fills this gap presenting an introduction to theory, experiment and computer simulation in this field. Based on tutorial lectures at a very successful recent Summer Institute, the presentation is ideally suited for graduate students, plasma physicists and experienced undergraduates.

  5. Ultracold Neutral Plasmas

    CERN Document Server

    Killian, T C; Gupta, P; Laha, S; Martinez, Y N; Mickelson, P G; Nagel, S B; Saenz, A D; Simien, C E; Killian, Thomas C.

    2005-01-01

    Ultracold neutral plasmas are formed by photoionizing laser-cooled atoms near the ionization threshold. Through the application of atomic physics techniques and diagnostics, these experiments stretch the boundaries of traditional neutral plasma physics. The electron temperature in these plasmas ranges from 1-1000 K and the ion temperature is around 1 K. The density can approach $10^{11}$ cm$^{-3}$. Fundamental interest stems from the possibility of creating strongly-coupled plasmas, but recombination, collective modes, and thermalization in these systems have also been studied. Optical absorption images of a strontium plasma, using the Sr$^+$ ${^2S_{1/2}} -> {^2P_{1/2}}$ transition at 422 nm, depict the density profile of the plasma, and probe kinetics on a 50 ns time-scale. The Doppler-broadened ion absorption spectrum measures the ion velocity distribution, which gives an accurate measure of the ion dynamics in the first microsecond after photoionization.

  6. What is a plasma?

    Energy Technology Data Exchange (ETDEWEB)

    Intrator, Thomas P. [Los Alamos National Laboratory

    2012-08-30

    This introduction will define the plasma fourth state of matter, where we find plasmas on earth and beyond, and why they are useful. There are applications to many consumer items, fusion energy, scientific devices, satellite communications, semiconductor processing, spacecraft propulsion, and more. Since 99% of our observable universe is ionized gas, plasma physics determines many important features of astrophysics, space physics, and magnetosphere physics in our solar system. We describe some plasma characteristics, examples in nature, some useful applications, how to create plasmas. A brief introduction to the theoretical framework includes the connection between kinetic and fluid descriptions, quasi neutrality, Debye shielding, ambipolar electric fields, some plasma waves. Hands-on demonstrations follow. More complete explanations will follow next week.

  7. Pulsed plasma electron sourcesa)

    Science.gov (United States)

    Krasik, Ya. E.; Yarmolich, D.; Gleizer, J. Z.; Vekselman, V.; Hadas, Y.; Gurovich, V. Tz.; Felsteiner, J.

    2009-05-01

    There is a continuous interest in research of electron sources which can be used for generation of uniform electron beams produced at E ≤105 V/cm and duration ≤10-5 s. In this review, several types of plasma electron sources will be considered, namely, passive (metal ceramic, velvet and carbon fiber with and without CsI coating, and multicapillary and multislot cathodes) and active (ferroelectric and hollow anodes) plasma sources. The operation of passive sources is governed by the formation of flashover plasma whose parameters depend on the amplitude and rise time of the accelerating electric field. In the case of ferroelectric and hollow-anode plasma sources the plasma parameters are controlled by the driving pulse and discharge current, respectively. Using different time- and space-resolved electrical, optical, spectroscopical, Thomson scattering and x-ray diagnostics, the parameters of the plasma and generated electron beam were characterized.

  8. Effects of Low-Temperature Plasma-Sterilization on Mars Analog Soil Samples Mixed with Deinococcus radiodurans

    Directory of Open Access Journals (Sweden)

    Janosch Schirmack

    2016-05-01

    Full Text Available We used Ar plasma-sterilization at a temperature below 80 °C to examine its effects on the viability of microorganisms when intermixed with tested soil. Due to a relatively low temperature, this method is not thought to affect the properties of a soil, particularly its organic component, to a significant degree. The method has previously been shown to work well on spacecraft parts. The selected microorganism for this test was Deinococcus radiodurans R1, which is known for its remarkable resistance to radiation effects. Our results showed a reduction in microbial counts after applying a low temperature plasma, but not to a degree suitable for a sterilization of the soil. Even an increase of the treatment duration from 1.5 to 45 min did not achieve satisfying results, but only resulted in in a mean cell reduction rate of 75% compared to the untreated control samples.

  9. Effects of Low-Temperature Plasma-Sterilization on Mars Analog Soil Samples Mixed with Deinococcus radiodurans

    Science.gov (United States)

    Schirmack, Janosch; Fiebrandt, Marcel; Stapelmann, Katharina; Schulze-Makuch, Dirk

    2016-01-01

    We used Ar plasma-sterilization at a temperature below 80 °C to examine its effects on the viability of microorganisms when intermixed with tested soil. Due to a relatively low temperature, this method is not thought to affect the properties of a soil, particularly its organic component, to a significant degree. The method has previously been shown to work well on spacecraft parts. The selected microorganism for this test was Deinococcus radiodurans R1, which is known for its remarkable resistance to radiation effects. Our results showed a reduction in microbial counts after applying a low temperature plasma, but not to a degree suitable for a sterilization of the soil. Even an increase of the treatment duration from 1.5 to 45 min did not achieve satisfying results, but only resulted in in a mean cell reduction rate of 75% compared to the untreated control samples. PMID:27240407

  10. Space plasma physics research

    Science.gov (United States)

    Comfort, Richard H.; Horwitz, James L.

    1993-01-01

    During the course of this grant, work was performed on a variety of topics and there were a number of significant accomplishments. A summary of these accomplishments is included. The topics studied include empirical model data base, data reduction for archiving, semikinetic modeling of low energy plasma in the inner terrestrial magnetosphere and ionosphere, O(+) outflows, equatorial plasma trough, and plasma wave ray-tracing studies. A list of publications and presentations which have resulted from this research is also included.

  11. Atmospheric Plasma Depainting

    Science.gov (United States)

    2014-11-19

    Plasma Carbon Dioxide Water Vapor 11 Atmospheric Plasma Depainting, ASETSDefense, Nov 19, 2014 Features and Benefits of APCR Technology Feature...Depainting, ASETSDefense, Nov 19, 2014 14 APC on Aluminum Removal to Primer RAM on Carbon Fiber Partial Topcoat Removal APC Topcoat RAM...60Hz Plasma Flux™ Power Supply VENT To Facility HEPA <= Filtration COTS Six-Axis Robot Aircraft part Particulate Collection System

  12. Plasma nitriding of steels

    CERN Document Server

    Aghajani, Hossein

    2017-01-01

    This book focuses on the effect of plasma nitriding on the properties of steels. Parameters of different grades of steels are considered, such as structural and constructional steels, stainless steels and tools steels. The reader will find within the text an introduction to nitriding treatment, the basis of plasma and its roll in nitriding. The authors also address the advantages and disadvantages of plasma nitriding in comparison with other nitriding methods. .

  13. Systematic Review of the Performance of HIV Viral Load Technologies on Plasma Samples

    Science.gov (United States)

    Sollis, Kimberly A.; Smit, Pieter W.; Fiscus, Susan; Ford, Nathan; Vitoria, Marco; Essajee, Shaffiq; Barnett, David; Cheng, Ben; Crowe, Suzanne M.; Denny, Thomas; Landay, Alan; Stevens, Wendy; Habiyambere, Vincent; Perrins, Jos; Peeling, Rosanna W.

    2014-01-01

    Background Viral load (VL) monitoring is the standard of care in developing country settings for detecting HIV treatment failure. Since 2010 the World Health Organization has recommended a phase-in approach to VL monitoring in resource-limited settings. We conducted a systematic review of the accuracy and precision of HIV VL technologies for treatment monitoring. Methods and Findings A search of Medline and Embase was conducted for studies evaluating the accuracy or reproducibility of commercially available HIV VL assays. 37 studies were included for review including evaluations of the Amplicor Monitor HIV-1 v1.5 (n = 25), Cobas TaqMan v2.0 (n = 11), Abbott RealTime HIV-1 (n = 23), Versant HIV-1 RNA bDNA 3.0 (n = 15), Versant HIV-1 RNA kPCR 1.0 (n = 2), ExaVir Load v3 (n = 2), and NucliSens EasyQ v2.0 (n = 1). All currently available HIV VL assays are of sufficient sensitivity to detect plasma virus levels at a lower detection limit of 1,000 copies/mL. Bias data comparing the Abbott RealTime HIV-1, TaqMan v2.0 to the Amplicor Monitor v1.5 showed a tendency of the Abbott RealTime HIV-1 to under-estimate results while the TaqMan v2.0 overestimated VL counts. Compared to the Amplicor Monitor v1.5, 2–26% and 9–70% of results from the Versant bDNA 3.0 and Abbott RealTime HIV-1 differed by greater than 0.5log10. The average intra and inter-assay variation of the Abbott RealTime HIV-1 were 2.95% (range 2.0–5.1%) and 5.44% (range 1.17–30.00%) across the range of VL counts (2log10–7log10). Conclusions This review found that all currently available HIV VL assays are of sufficient sensitivity to detect plasma VL of 1,000 copies/mL as a threshold to initiate investigations of treatment adherence or possible treatment failure. Sources of variability between VL assays include differences in technology platform, plasma input volume, and ability to detect HIV-1 subtypes. Monitoring of individual patients should be performed on the same

  14. Systematic review of the performance of HIV viral load technologies on plasma samples.

    Directory of Open Access Journals (Sweden)

    Kimberly A Sollis

    Full Text Available BACKGROUND: Viral load (VL monitoring is the standard of care in developing country settings for detecting HIV treatment failure. Since 2010 the World Health Organization has recommended a phase-in approach to VL monitoring in resource-limited settings. We conducted a systematic review of the accuracy and precision of HIV VL technologies for treatment monitoring. METHODS AND FINDINGS: A search of Medline and Embase was conducted for studies evaluating the accuracy or reproducibility of commercially available HIV VL assays. 37 studies were included for review including evaluations of the Amplicor Monitor HIV-1 v1.5 (n = 25, Cobas TaqMan v2.0 (n = 11, Abbott RealTime HIV-1 (n = 23, Versant HIV-1 RNA bDNA 3.0 (n = 15, Versant HIV-1 RNA kPCR 1.0 (n = 2, ExaVir Load v3 (n = 2, and NucliSens EasyQ v2.0 (n = 1. All currently available HIV VL assays are of sufficient sensitivity to detect plasma virus levels at a lower detection limit of 1,000 copies/mL. Bias data comparing the Abbott RealTime HIV-1, TaqMan v2.0 to the Amplicor Monitor v1.5 showed a tendency of the Abbott RealTime HIV-1 to under-estimate results while the TaqMan v2.0 overestimated VL counts. Compared to the Amplicor Monitor v1.5, 2-26% and 9-70% of results from the Versant bDNA 3.0 and Abbott RealTime HIV-1 differed by greater than 0.5log10. The average intra and inter-assay variation of the Abbott RealTime HIV-1 were 2.95% (range 2.0-5.1% and 5.44% (range 1.17-30.00% across the range of VL counts (2log10-7log10. CONCLUSIONS: This review found that all currently available HIV VL assays are of sufficient sensitivity to detect plasma VL of 1,000 copies/mL as a threshold to initiate investigations of treatment adherence or possible treatment failure. Sources of variability between VL assays include differences in technology platform, plasma input volume, and ability to detect HIV-1 subtypes. Monitoring of individual patients should be performed on the same

  15. Plasma adiabatic lapse rate

    CERN Document Server

    Amendt, Peter; Wilks, Scott

    2012-01-01

    The plasma analog of an adiabatic lapse rate (or temperature variation with height) in atmospheric physics is obtained. A new source of plasma temperature gradient in a binary ion species mixture is found that is proportional to the concentration gradient and difference in average ionization states . Application to inertial-confinement-fusion implosions indicates a potentially strong effect in plastic (CH) ablators that is not modeled with mainline (single-fluid) simulations. An associated plasma thermodiffusion coefficient is derived, and charge-state diffusion in a single-species plasma is also predicted.

  16. Nonlinear Physics of Plasmas

    CERN Document Server

    Kono, Mitsuo

    2010-01-01

    A nonlinearity is one of the most important notions in modern physics. A plasma is rich in nonlinearities and provides a variety of behaviors inherent to instabilities, coherent wave structures and turbulence. The book covers the basic concepts and mathematical methods, necessary to comprehend nonlinear problems widely encountered in contemporary plasmas, but also in other fields of physics and current research on self-organized structures and magnetized plasma turbulence. The analyses make use of strongly nonlinear models solved by analytical techniques backed by extensive simulations and available experiments. The text is written for senior undergraduates, graduate students, lecturers and researchers in laboratory, space and fusion plasmas.

  17. Physics of Plasmas

    CERN Document Server

    Woods, Leslie Colin

    2003-01-01

    A short, self-sufficient introduction to the physics of plasma for beginners as well as researchers in a number of fields. The author looks at the dynamics and stability of magnetoplasma and discusses wave and transport in this medium. He also looks at such applications as fusion research using magnetic confinement of Deuterium plasma, solar physics with its plasma loops reaching high into the corona, sunspots and solar wind, engineering applications to metallurgy, MHD direct generation of electricity, and railguns, finally touching on the relatively new and difficult subject of dusty plasmas.

  18. Princeton Plasma Physics Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    1990-01-01

    This report discusses the following topics: principal parameters achieved in experimental devices fiscal year 1990; tokamak fusion test reactor; compact ignition tokamak; Princeton beta experiment- modification; current drive experiment-upgrade; international collaboration; x-ray laser studies; spacecraft glow experiment; plasma processing: deposition and etching of thin films; theoretical studies; tokamak modeling; international thermonuclear experimental reactor; engineering department; project planning and safety office; quality assurance and reliability; technology transfer; administrative operations; PPPL patent invention disclosures for fiscal year 1990; graduate education; plasma physics; graduate education: plasma science and technology; science education program; and Princeton Plasma Physics Laboratory reports fiscal year 1990.

  19. Solid expellant plasma generator

    Science.gov (United States)

    Stone, Nobie H. (Inventor); Poe, Garrett D. (Inventor); Rood, Robert (Inventor)

    2010-01-01

    An improved solid expellant plasma generator has been developed. The plasma generator includes a support housing, an electrode rod located in the central portion of the housing, and a mass of solid expellant material that surrounds the electrode rod within the support housing. The electrode rod and the solid expellant material are made of separate materials that are selected so that the electrode and the solid expellant material decompose at the same rate when the plasma generator is ignited. This maintains a point of discharge of the plasma at the interface between the electrode and the solid expellant material.

  20. Plasma processing for VLSI

    CERN Document Server

    Einspruch, Norman G

    1984-01-01

    VLSI Electronics: Microstructure Science, Volume 8: Plasma Processing for VLSI (Very Large Scale Integration) discusses the utilization of plasmas for general semiconductor processing. It also includes expositions on advanced deposition of materials for metallization, lithographic methods that use plasmas as exposure sources and for multiple resist patterning, and device structures made possible by anisotropic etching.This volume is divided into four sections. It begins with the history of plasma processing, a discussion of some of the early developments and trends for VLSI. The second section

  1. Plasma and particles

    Science.gov (United States)

    Špatenka, Petr; Vacková, Tat'ana; Nováček, Vojtěch; Jeníková, Zdenka

    2016-12-01

    Plasma has been proved as a standard industrial method for surface treatment of solid bulk materials. Recently plasma has also been used in connection with production, treatment and functionalization of powder and granulate materials. Functionalization was originally developed for hydrophylization of hydrophobic surfaces of particles made from various materials. An industrial scale device with a capacity of several hundreds of tons per year based on plasma treatment will be presented. As examples of the applications are given plasma treated polyethylene powder dispersed in the water; and very good adhesion of polymer powders to metals or glass, which is promising for development of new generation of thermoplastic composites.

  2. Multiple stage MS in analysis of plasma, serum, urine and in vitro samples relevant to clinical and forensic toxicology.

    Science.gov (United States)

    Meyer, Golo M; Maurer, Hans H; Meyer, Markus R

    2016-01-01

    This paper reviews MS approaches applied to metabolism studies, structure elucidation and qualitative or quantitative screening of drugs (of abuse) and/or their metabolites. Applications in clinical and forensic toxicology were included using blood plasma or serum, urine, in vitro samples, liquids, solids or plant material. Techniques covered are liquid chromatography coupled to low-resolution and high-resolution multiple stage mass analyzers. Only PubMed listed studies published in English between January 2008 and January 2015 were considered. Approaches are discussed focusing on sample preparation and mass spectral settings. Comments on advantages and limitations of these techniques complete the review.

  3. A Comparison between Ion chromatography and Inductively Coupled Plasma for the Determination of Bromate in Certain Samples of Foodstuffs

    Directory of Open Access Journals (Sweden)

    Alanowd O. Mehder

    2015-06-01

    Full Text Available Ion chromatography (IC and inductively coupled plasma (ICP-MS both were applied for the determination of bromate in some food samples. Attempts were made to establish calibration curves, however in case of IC, an additional abnormal peak was found to overlap with the bromate peak. This renders IC to be unsuccessful in the determination of bromate compared to ICP-MS technique. ICP-MS was found to give accurate results; therefore, it was applied for the determination of bromate in different samples of food stuffs.

  4. Plasma Modeling of Electrosurgery

    Science.gov (United States)

    Jensen, Scott; Friedrichs, Daniel; Gilbert, James; Park, Wounjhang; Maksimovic, Dragan

    2014-10-01

    Electrosurgery is the use of high frequency alternating current (AC) to illicit a clinical response in tissue, such as cutting or cauterization. Power electronics converters have been demonstrated to generate the necessary output voltage and current for electrosurgery. The design goal of the converter is to regulate output power while supplying high frequency AC. The design is complicated by fast current and voltage transients that occur when the current travels through air in the form of an arc. To assist in designing a converter that maintains the desired output power during these transients, we have used the COMSOL Plasma Module to determine the output voltage and current characteristics during an arc. This plasma model, used in conjunction with linear circuit elements, allows the full electrosurgical system to be validated. Two models have been tested with the COMSOL Plasma Module. One is a four-species, four-reaction model based on the local field approximation technique. The second simulates the underlying air chemistry using 30 species, 151 chemical reactions, and a coupled electron energy distribution function. Experimental output voltage and current samples have been collected and compared to both models.

  5. Radionuclide Determination In Surface Water Samples By Inductively Coupled Plasma With Sector Field Mass Spectrometry (ICP-SFMS

    Directory of Open Access Journals (Sweden)

    E. T. Romero-Guzmán

    2016-08-01

    Full Text Available The determination of naturally occurring radionuclides in the environment by inductively coupled plasma mass spectrometry of high resolution (ICP-SFMS has gained recognition over the last fifteen years, relative to the radiometric techniques, as the result of improvement in instrumental performance, sample introduction equipment and sample preparation. With the increase in instrumental sensitivity, it is now possible to measure ultratrace levels of many radioisotopes. The aim of this work was to determined the natural radionuclides (232Th, 234U, 235U and 238U in surface water using Inductively Coupled PlasmaSector Field Mass Spectrometry (ICP-SFMS. The samples were sampling from Lerma river, State of Mexico at february to april 2015. The process of treatment of sample consisted in perform an acid digestion according to the 3015A USEPA method followed of the direct measurement in ICP-SFMS. Results obtained were: a identify the presence of 232Th, 234U, 235U and 238U isotopes in water, b isotopic ratios were for 234U/238U=1.133 ± 0.016. ICPSFMS has gained popularity in the field of radiochemistry, particularly as a method of detection for long lived-actinides.

  6. Multi-elemental analysis of aqueous geochemical samples by quadrupole inductively coupled plasma-mass spectrometry (ICP-MS)

    Science.gov (United States)

    Wolf, Ruth E.; Adams, Monique

    2015-01-01

    Typically, quadrupole inductively coupled plasma-mass spectrometry (ICP-MS) is used to determine as many as 57 major, minor, and trace elements in aqueous geochemical samples, including natural surface water and groundwater, acid mine drainage water, and extracts or leachates from geological samples. The sample solution is aspirated into the inductively coupled plasma (ICP) which is an electrodeless discharge of ionized argon gas at a temperature of approximately 6,000 degrees Celsius. The elements in the sample solution are subsequently volatilized, atomized, and ionized by the ICP. The ions generated are then focused and introduced into a quadrupole mass filter which only allows one mass to reach the detector at a given moment in time. As the settings of the mass analyzer change, subsequent masses are allowed to impact the detector. Although the typical quadrupole ICP-MS system is a sequential scanning instrument (determining each mass separately), the scan speed of modern instruments is on the order of several thousand masses per second. Consequently, typical total sample analysis times of 2–3 minutes are readily achievable for up to 57 elements.

  7. Plasma Physics An Introduction to Laboratory, Space, and Fusion Plasmas

    CERN Document Server

    Piel, Alexander

    2010-01-01

    Plasma Physics gives a comprehensive introduction to the basic processes in plasmas and demonstrates that the same fundamental concepts describe cold gas-discharge plasmas, space plasmas, and hot fusion plasmas. Starting from particle drifts in magnetic fields, the principles of magnetic confinement fusion are explained and compared with laser fusion. Collective processes are discussed in terms of plasma waves and instabilities. The concepts of plasma description by magnetohydrodynamics, kinetic theory, and particle simulation are stepwise introduced. Space charge effects in sheath regions, double layers and plasma diodes are given the necessary attention. The new fundamental mechanisms of dusty plasmas are explored and integrated into the framework of conventional plasmas. The book concludes with a brief introduction to plasma discharges. Written by an internationally renowned researcher in experimental plasma physics, the text keeps the mathematical apparatus simple and emphasizes the underlying concepts. T...

  8. [Acute plasma cell leukemia].

    Science.gov (United States)

    Monsalbe, V; Domíngues, C; Roa, I; Busel, D; González, S

    1989-01-01

    Plasma Cell Leukemia is a very rare form of plasmocytic dyscrasia, whose clinical and pathological characteristics warrant its recognition as a distinct subentity. We report the case of a 60 years old man who presented a rapidly fatal acute plasma cell leukemia, with multiple osteolytic lesions, hipercalcemia, renal and cardiac failure.

  9. Plasma polarization spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, Takashi [Department of Engineering Physics and Mechanics, Graduate School of Engineering, Kyoto University, Kyoto (Japan)

    2000-03-01

    Polarization of radiation emitted from a plasma reflects the anisotropic properties of the plasma, especially the angular anisotropic distribution of electron velocities. Polarization has been observed on impurity ion lines from the WT-3 tokamak and the GAMMA-10 tandem mirror machines. The soft x-ray laser line from the neonlike germanium was also found polarized. (author)

  10. Plasma polarization spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Iwamae, Atsushi; Inoue, Takeru; Tanaka, Akihiro; Kawakami, Kazuki; Fujimoto, Takashi [Kyoto Univ., Dept. of Engineering Physics, Kyoto (Japan)

    2000-03-01

    Polarization of radiation emitted from plasma reflects the anisotropic properties of the plasma, especially the angular isotropic distribution of electron velocities. Polarization has been observed on impurity ion lines from the WT-3 tokamak and GAMMA 10 tandem mirror device. (author)

  11. Atoms in dense plasmas

    Energy Technology Data Exchange (ETDEWEB)

    More, R.M.

    1986-01-01

    Recent experiments with high-power pulsed lasers have strongly encouraged the development of improved theoretical understanding of highly charged ions in a dense plasma environment. This work examines the theory of dense plasmas with emphasis on general rules which govern matter at extreme high temperature and density. 106 refs., 23 figs.

  12. Plasma etching an introduction

    CERN Document Server

    Manos, Dennis M

    1989-01-01

    Plasma etching plays an essential role in microelectronic circuit manufacturing. Suitable for researchers, process engineers, and graduate students, this book introduces the basic physics and chemistry of electrical discharges and relates them to plasma etching mechanisms. Throughout the volume the authors offer practical examples of process chemistry, equipment design, and production methods.

  13. Modelling of Complex Plasmas

    NARCIS (Netherlands)

    Akdim, M.R. (Mohamed Reda)

    2003-01-01

    Nowadays plasmas are used for various applications such as the fabrication of silicon solar cells, integrated circuits, coatings and dental cleaning. In the case of a processing plasma, e.g. for the fabrication of amorphous silicon solar cells, a mixture of silane and hydrogen gas is injected in a r

  14. "Angular" plasma cell cheilitis.

    Science.gov (United States)

    da Cunha Filho, Roberto Rheingantz; Tochetto, Lucas Baldissera; Tochetto, Bruno Baldissera; de Almeida, Hiram Larangeira; Lorencette, Nádia Aparecida; Netto, José Fillus

    2014-03-17

    Plasma cell cheilitis is an extremely rare disease, characterized by erythematous-violaceous, ulcerated and asymptomatic plaques, which evolve slowly. The histological characteristics include dermal infiltrate composed of mature plasmocytes. We report a case of Plasma cell angular cheilitis in a 58-year-old male, localized in the lateral oral commissure.

  15. "Angular" plasma cell cheilitis

    OpenAIRE

    da Cunha Filho, Roberto Rheingantz; Tochetto, Lucas Baldissera; Tochetto, Bruno Baldissera; de Almeida Jr, Hiram Larangeira; Lorencette, Nadia Aparecida; Netto, Jose Fillus

    2014-01-01

    Plasma cell cheilitis is an extremely rare disease, characterized by erythematous-violaceous, ulcerated and asymptomatic plaques, which evolve slowly. The histological characteristics include dermal infiltrate composed of mature plasmocytes. We report a case of Plasma cell angular cheilitis in a 58-year-old male, localized in the lateral oral commissure.

  16. Introduction to Plasma Spectroscopy

    CERN Document Server

    Kunze, H-J

    2009-01-01

    Based on lectures given at the Ruhr-University of Bochum for graduate students and postgraduates starting in plasma physics as well as from low- to high-density hot plasmas, this book introduces basic ideas and fundamental concepts and typical instrumentation from the X-ray to the infrared spectral regions

  17. Solid-Sampling Electrothermal Vaporization Inductively Coupled Plasma Optical Emission Spectrometry for Direct Determination of Total Oxygen in Coal.

    Science.gov (United States)

    Vogt, Thomas; Bauer, Daniela; Nennstiel, David; Otto, Matthias

    2015-10-20

    A new analytical method for direct determination of total oxygen contents in eight coal samples of the Argonne Premium Coal (APC) series and in the NIST SRM 1632d is presented. The development of a suitable calibration procedure, optimization of measurement conditions, and the application of a tailored data processing for handling of plasma effects and high blanks enable the quantification of oxygen simultaneously with other trace, minor, or major elements in whole coal samples by means of electrothermal vaporization inductively coupled plasma optical emission spectrometry (ETV-ICP OES). For comparison, the oxygen contents were determined by a direct oxygen analyzer. The obtained oxygen values of the APC and the reference material NIST SRM 1632d were compared to data in the literature. The precision of the ETV-ICP OES was within ±3.5%, and the recovery better than 92%. With this good accuracy, the developed direct solid sampling method ETV-ICP OES is well suited for the fast determination of oxygen in coals, varying in rank from lignite to semianthracite, in a content range of about 100 ppm up to 27% using 1.5 mg sample weight. This direct analysis method represents an accurate, advantageous alternative to currently used methods for estimation of total oxygen contents in coals.

  18. Polybrominated diphenyl ethers in paired samples of maternal and umbilical cord blood plasma and associations with house dust in a Danish cohort

    DEFF Research Database (Denmark)

    Frederiksen, Marie; Thomsen, Cathrine; Frøshaug, May

    2010-01-01

    . The sum of tri- to hexa-BDEs (SigmaPBDE) in maternal plasma varied between 640 and 51,946pg/g lipid weight (lw) with a median level of 1765pg/g lw. In the umbilical cord samples SigmaPBDE varied between 213 and 54,346pg/g lw with a median of 958pg/g lw. The levels observed in fetal and maternal plasma...... individuals. Furthermore, positive correlations (pSigmaPBDE in maternal plasma and house dust as well as for SigmaPBDE in umbilical cord plasma and house dust. The positive correlations for PBDEs for both maternal and umbilical cord plasma with house dust showed...

  19. Innovations in plasma sensors

    Science.gov (United States)

    Zurbuchen, Thomas H.; Gershman, Daniel J.

    2016-04-01

    During the history of space exploration, ever improving instruments have continued to enable new measurements and discoveries. Focusing on plasma sensors, we examine the processes by which such new instrument innovations have occurred over the past decades. Due to risk intolerance prevalent in many NASA space missions, innovations in plasma instrumentation occur primarily when heritage systems fail to meet science requirements, functional requirements as part of its space platform, or design constraints. We will review such innovation triggers in the context of the design literature and with the help of two case studies, the Fast Imaging Plasma Spectrometer on MErcury Surface, Space ENvironment, GEochemistry, and Ranging and the Fast Plasma Investigation on Magnetosphere Multiscale. We will then discuss the anticipated needs for new plasma instrument innovations to enable the science program of the next decade.

  20. Wakes in inhomogeneous plasmas

    CERN Document Server

    Kompaneets, Roman; Nosenko, Vladimir; Morfill, Gregor E

    2014-01-01

    The Debye shielding of a charge immersed in a flowing plasma is an old classic problem in plasma physics. It has been given renewed attention in the last two decades in view of experiments with complex plasmas, where charged dust particles are often levitated in a region with strong ion flow. Efforts to describe the shielding of the dust particles in such conditions have been focused on the homogeneous plasma approximation, which ignores the substantial inhomogeneity of the levitation region. We address the role of the plasma inhomogeneity by rigorously calculating the point charge potential in the collisionless Bohm sheath. We demonstrate that the inhomogeneity can dramatically modify the wake, making it non-oscillatory and weaker.

  1. Basic plasma physics

    CERN Document Server

    Ghosh, Basudev

    2014-01-01

    Basic Plasma Physics is designed to serve as an introductory compact textbook for advanced undergraduate, postgraduate and research students taking plasma physics as one of their subject of study for the first time. It covers the current syllabus of plasma physics offered by the most universities and technical institutions. The book requires no background in plasma physics but only elementary knowledge of basic physics and mathematics. Emphasis has been given on the analytical approach. Topics are developed from first principle so that the students can learn through self-study. One chapter has been devoted to describe some practical aspects of plasma physics. Each chapter contains a good number of solved and unsolved problems and a variety of review questions, mostly taken from recent examination papers. Some classroom experiments described in the book will surely help students as well as instructors.

  2. Microphysics of cosmic plasmas

    CERN Document Server

    Bykov, Andrei; Cargill, Peter; Dendy, Richard; Wit, Thierry; Raymond, John

    2014-01-01

    This title presents a review of the detailed aspects of the physical processes that underlie the observed properties, structures and dynamics of cosmic plasmas. An assessment of the status of understanding of microscale processes in all astrophysical collisionless plasmas is provided. The topics discussed include  turbulence in astrophysical and solar system plasmas as a phenomenological description of their dynamic properties on all scales; observational, theoretical and modelling aspects of collisionless magnetic reconnection; the formation and dynamics of shock waves; and a review and assessment of microprocesses, such as the hierarchy of plasma instabilities, non-local and non-diffusive transport processes and ionisation and radiation processes.  In addition, some of the lessons that have been learned from the extensive existing knowledge of laboratory plasmas as applied to astrophysical problems are also covered.   This volume is aimed at graduate students and researchers active in the areas of cosmi...

  3. SUPERFAST THERMALIZATION OF PLASMA

    Science.gov (United States)

    Chang, C.C.

    1962-06-12

    A method is given for the superfast thermalization of plasma by shock conversion of the kinetic energy stored in rotating plasma rings or plasmoids colliding at near supersonic speeds in a containment field to heat energy in the resultant confined plasma mass. The method includes means for generating rotating plasmoids at the opposite ends of a Pyrotron or Astron containment field. The plasmoids are magnetically accelerated towards each other into the opposite ends of time containment field. During acceleration of the plasmoids toward the center of the containment field, the intensity of the field is sequentially increased to adiabatically compress the plasmoids and increase the plasma energy. The plasmoids hence collide with a violent shock at the eenter of the containment field, causing the substantial kinetic energy stored in the plasmoids to be converted to heat in the resultant plasma mass. (AEC)

  4. Plasma polymerization by Softplasma

    DEFF Research Database (Denmark)

    Jiang, J.; Wu, Zhenning; Benter, Maike

    2008-01-01

    as reactive splvent (as shown in Figure 1). 1] H. Biederman, in Plasma Polymer Films. (ed.) H. Biederman. Imperial College Press, Singapore, 13-24 ~OO~· '. , [2] R. d'Agostino et.a!. in Plasma Depd~itiqn, 'Treatment, and Etching ofPolymers. (ed.) R. d'Agostino, Academic Press, U.S. (1990). [3] F. F. Shi......In the late 19th century, the first depositions - known today as plasma polymers, were reported. In the last century, more and more research has been put into plasma polymers. Many different deposition systems have been developed. [1, 2] Shi F. F. broadly classified them into internal electrode......, external electrode, and electrodeless microwave or high frequency reactors. [3] Softplasma™ is an internal electrode plasma setup powered by low frequenc~ gower supply. It was developed in late 90s for surface treatment of silicone rubber. [ ]- 5] It is a low pressure, low electron density, 3D homogenous...

  5. Gingival plasma cell granuloma

    Directory of Open Access Journals (Sweden)

    Phadnaik Mangesh

    2010-01-01

    Full Text Available Plasma cell granuloma is a rare reactive lesion composed of polyclonal plasma cells. It manifests primarily in the lungs, but may occur in various other anatomic locations like the oral cavity. Intraoral plasma cell granulomas involving the tongue, lip, oral mucosa and gingiva have been reported in the past. This case presents a 54-year-old female with chronic periodontitis and mandibular anterior gingival overgrowth treated by Phase I therapy (scaling and root planing and excisional biopsy. Histological examination revealed inflammatory cell infiltrate containing sheets of plasma cells. Immunohistochemistry for kappa and lambda light chains showed a polyclonal staining pattern confirming a diagnosis of plasma cell granuloma. This case highlights the need to biopsy for unusual lesions to rule out potential neoplasms.

  6. Helical plasma thruster

    Energy Technology Data Exchange (ETDEWEB)

    Beklemishev, A. D., E-mail: bekl@bk.ru [Budker Institute of Nuclear Physics SB RAS, Novosibirsk (Russian Federation)

    2015-10-15

    A new scheme of plasma thruster is proposed. It is based on axial acceleration of rotating magnetized plasmas in magnetic field with helical corrugation. The idea is that the propellant ionization zone can be placed into the local magnetic well, so that initially the ions are trapped. The E × B rotation is provided by an applied radial electric field that makes the setup similar to a magnetron discharge. Then, from the rotating plasma viewpoint, the magnetic wells of the helically corrugated field look like axially moving mirror traps. Specific shaping of the corrugation can allow continuous acceleration of trapped plasma ions along the magnetic field by diamagnetic forces. The accelerated propellant is expelled through the expanding field of magnetic nozzle. By features of the acceleration principle, the helical plasma thruster may operate at high energy densities but requires a rather high axial magnetic field, which places it in the same class as the VASIMR{sup ®} rocket engine.

  7. Diagnostics of Nanodusty Plasma

    Science.gov (United States)

    Greiner, Franko; Groth, Sebastian; Tadsen, Bejamin; Piel, Alexander

    2015-11-01

    The diagnostic of nanodusty plasmas, i.e. plasmas including nano-sized dust particles, is a challenging task. For both, the diagnostic of the nanodusty plasma itself, and the in-situ diagnostic of the nanoparticles, no standard diagnostic exist. Nanodust particle size and density can be estimated using light scattering techniques, namely kinetic Mie ellipsometry and extinction measurements. The charge of the nanoparticles can be estimated from the analysis of dust density waves (DDW). Parameters like the electron density, which give information about the plasma itself, may be deduced from the DDW analysis. We present detailed investigations on nanodust in a reactive Argon-Acetylene plasma created in an rf-driven parallel plate reactor at low pressure using the above mentioned portfolio of diagnostic. Funded by DFG under contract SFB TR-24/A2.

  8. Solar system plasma waves

    Science.gov (United States)

    Gurnett, Donald A.

    1995-01-01

    An overview is given of spacecraft observations of plasma waves in the solar system. In situ measurements of plasma phenomena have now been obtained at all of the planets except Mercury and Pluto, and in the interplanetary medium at heliocentric radial distances ranging from 0.29 to 58 AU. To illustrate the range of phenomena involved, we discuss plasma waves in three regions of physical interest: (1) planetary radiation belts, (2) planetary auroral acceleration regions and (3) the solar wind. In each region we describe examples of plasma waves that are of some importance, either due to the role they play in determining the physical properties of the plasma, or to the unique mechanism involved in their generation.

  9. Electronegative Plasma Instabilities in Industrial Pulsed Plasmas

    Science.gov (United States)

    Pribyl, Patrick; Hansen, Anders; Gekelman, Walter

    2016-10-01

    Electronegative gases that are important for industrial etch processes have a series of instabilities that occur at process relevant conditions. These have been studied since the 1990s, but are becoming a much more important today as plasma reactors are being pushed to produce ever finer features, and tight control of the etch process is becoming crucial. The experiments are being done in a plasma etch tool that closely simulates a working industrial device. ICP coils in different configurations are driven by a pulsed RF generators operating at 2-5 MHz. A computer controlled automated probe drive can access a volume above the substrate. The probe can be a Langmuir probe, a ``Bdot'' probe, or an emissive probe the latter used for more accurate determination of plasma potential. A microwave interferometer is available to measure line-averaged electron density. The negative ion instability is triggered depending upon the gas mix (Ar,SF6) , pressure and RF power. The instability can be ``burned through'' by rapidly pulsing the RF power. In this study we present measurements of plasma current and density distribution over the wafer before, after and during the rapid onset of the instability. Work suported by NSF-GOALI Award and done at the BAPSF.

  10. Determination of cadmium, mercury and lead in coal fly ash by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Liao, H.C.; Jiang, S.J. [National Sun Yat Sen University, Kaohsiung (Taiwan). Dept. of Chemistry

    1999-08-09

    Ultrasonic slurry sampling electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry (USS-ETV-ID-ICP-MS) was used to the determine Cd, Hg and Pb in coal fly ash samples. Thioacetamide (TAC) was the modifier. Since the sensitivities of the elements studied in coal fly ash slurry and aqueous solution were quite different, isotope dilution method was used for the determination of Cd, Hg and Pb in the coal fly ash samples. The isotope ratios of each element were calculated from the peak areas of each injection peak. This method was applied to the determination of Cd, Hg and Pb in NIST SRM 1633a coal fly ash reference material and a coal fly ash sample collected from Kaohsiung area. Detection limits estimated from standard addition curves were in the range of 24-58, 6-28 and 108-110 ng g{sup -1} for Cd, Hg and Pb, respectively.

  11. The plasma focus as a tool for plasma-wall-interaction studies

    Science.gov (United States)

    Ramos, G.; Martinez, M.; Herrera, J. J. E.; Castillo, F.

    2015-03-01

    The study of the interaction of magnetized plasmas with candidate materials for fusion reactors, as for example tungsten, is a main topic in fusion research. Many studies simulate the plasma wall interaction using ion beams, while only a few use plasma simulators. Plasma foci can produce dense magnetized plasmas of deuterium and helium among other species. We used the plasma focus Fuego-Nuevo II, to expose tungsten samples to deuterium and helium plasmas. The samples were analysed by means of SEM, RBS and NRA, evidencing surface erosion, surface melting and retention of deuterium in a shallow surface layer of 250 nm amounting 6.5·1016 D/cm2. The plasma temperature has been measured at the position of the samples using a triple Langmuir probe and compared to calculations of a snowplow model. The modelling of the electrode to reach desired plasma parameters is discussed.

  12. A needle extraction utilizing a molecularly imprinted-sol-gel xerogel for on-line microextraction of the lung cancer biomarker bilirubin from plasma and urine samples.

    Science.gov (United States)

    Moein, Mohammad Mahdi; Jabbar, Dunia; Colmsjö, Anders; Abdel-Rehim, Mohamed

    2014-10-31

    In the present work, a needle trap utilizing a molecularly imprinted sol-gel xerogel was prepared for the on-line microextraction of bilirubin from plasma and urine samples. Each prepared needle could be used for approximately one hundred extractions before it was discarded. Imprinted and non-imprinted sol-gel xerogel were applied for the extraction of bilirubin from plasma and urine samples. The produced molecularly imprinted sol-gel xerogel polymer showed high binding capacity and fast adsorption/desorption kinetics for bilirubin in plasma and urine samples. The adsorption capacity of molecularly imprinted sol-gel xerogel polymer was approximately 60% higher than that of non-imprinted polymer. The effect of the conditioning, washing and elution solvents, pH, extraction time, adsorption capacity and imprinting factor were investigated. The limit of detection and the lower limit of quantification were set to 1.6 and 5nmolL(-1), respectively using plasma or urine samples. The standard calibration curves were obtained within the concentration range of 5-1000nmolL(-1) in both plasma and urine samples. The coefficients of determination values (R(2)) were ≥0.998 for all runs. The extraction recovery was approximately 80% for BR in the human plasma and urine samples.

  13. Nonthermal plasma chemistry and physics

    CERN Document Server

    Meichsner, Jurgen; Schneider, Ralf; Wagner, Hans-Erich

    2013-01-01

    In addition to introducing the basics of plasma physics, Nonthermal Plasma Chemistry and Physics is a comprehensive presentation of recent developments in the rapidly growing field of nonthermal plasma chemistry. The book offers a detailed discussion of the fundamentals of plasma chemical reactions and modeling, nonthermal plasma sources, relevant diagnostic techniques, and selected applications.Elucidating interconnections and trends, the book focuses on basic principles and illustrations across a broad field of applications. Expert contributors address environmental aspects of plasma chemist

  14. Plasma physics an introduction to laboratory, space, and fusion plasmas

    CERN Document Server

    Piel, Alexander

    2017-01-01

    The enlarged new edition of this textbook provides a comprehensive introduction to the basic processes in plasmas and demonstrates that the same fundamental concepts describe cold gas-discharge plasmas, space plasmas, and hot fusion plasmas. Starting from particle drifts in magnetic fields, the principles of magnetic confinement fusion are explained and compared with laser fusion. Collective processes are discussed in terms of plasma waves and instabilities. The concepts of plasma description by magnetohydrodynamics, kinetic theory, and particle simulation are stepwise introduced. Space charge effects in sheath regions, double layers and plasma diodes are given the necessary attention. The novel fundamental mechanisms of dusty plasmas are explored and integrated into the framework of conventional plasmas. The book concludes with a concise description of modern plasma discharges. Written by an internationally renowned researcher in experimental plasma physics, the text keeps the mathematical apparatus simple a...

  15. Urine and plasma propranolol.

    Science.gov (United States)

    Andreasen, F; Jakobsen, P; Kornerup, H J; Pedersen, E B; Pedersen, O L

    1983-01-01

    Eight hypertensive patients who had been followed in an outpatient clinic during long-term therapy with propranolol (40 to 160 mg twice daily) were studied during a 24-hr stay in the ward. The usual oral dose was given and the total and free plasma concentrations were determined during the 24 hr and the urinary excretion of unchanged drug was measured. Average free plasma concentration of propranolol (y free) was calculated from: y free = Excreted propranolol (ng/24 hr)/Creatinine clearance (ml/24 hr). There was a significant relationship between log y free and average free plasma concentration (means free) determined from the directly measured plasma concentration curve: log y free = 0.0743 means free - 0.0466 (r = 0.98, P less than 0.001). In another group of propranolol-treated hypertensive patients there was a significant positive relationship between orosomucoid concentration and reciprocal of the free propranolol fraction in plasma. From this relationship the average total drug concentration (y total) was calculated from y free; there was a significant correlation with directly measured total plasma level: log y total = 0.0038 . means total + 1.0895 (r = 0.91, P less than 0.001). It is suggested that individually determined values of y free below 30 ng/ml and y total below 400 ng/ml (the concentration range studied) can be used to calculate the average mean 24-hr free and total plasma concentrations.

  16. Dense Hypervelocity Plasma Jets

    Science.gov (United States)

    Case, Andrew; Witherspoon, F. Douglas; Messer, Sarah; Bomgardner, Richard; Phillips, Michael; van Doren, David; Elton, Raymond; Uzun-Kaymak, Ilker

    2007-11-01

    We are developing high velocity dense plasma jets for fusion and HEDP applications. Traditional coaxial plasma accelerators suffer from the blow-by instability which limits the mass accelerated to high velocity. In the current design blow-by is delayed by a combination of electrode shaping and use of a tailored plasma armature created by injection of a high density plasma at a few eV generated by arrays of capillary discharges or sparkgaps. Experimental data will be presented for a complete 32 injector gun system built for driving rotation in the Maryland MCX experiment, including data on penetration of the plasma jet through a magnetic field. We present spectroscopic measurements of plasma velocity, temperature, and density, as well as total momentum measured using a ballistic pendulum. Measurements are in agreement with each other and with time of flight data from photodiodes and a multichannel PMT. Plasma density is above 10^15 cm-3, velocities range up to about 100 km/s. Preliminary results from a quadrature heterodyne HeNe interferometer are consistent with these results.

  17. Plasma Science Committee (PLSC)

    Science.gov (United States)

    1990-12-01

    The Plasma Science Committee (PLSC) is a standing committee under the auspices of the Board on Physics and Astronomy, Commission on Physical Sciences, Mathematics, and Applications of the National Academy of Sciences - National Research Council. Plasma sciences represent a broad and diverse field. The PLSC has accepted the responsibility of monitoring the continuing development and assessing the general health of the field as whole. Although select advisory bodies have been created to address specific issues that affect plasma science, such as the Fusion Policy Advisory Committee (FPAC), the PLSC provides a focus for the plasma science community that is unique and essential. The membership of the PLSC is drawn from research laboratories in universities, industry, and government. Areas of expertise on the committee include accelerators and beams, space physics, astrophysics, computational physics and applied mathematics, fusion plasmas, fundamental experiments and theory, radiation sources, low temperature plasmas, and plasma-surface interactions. The PLSC is well prepared to respond to requests for studies on specific issues.

  18. Online Determination of Sm, Eu and Yb in Environmental Samples by Inductively Coupled Plasma – Optical Emission Spectrometry

    Directory of Open Access Journals (Sweden)

    J. Dilip Kumar

    2007-01-01

    Full Text Available A procedure was developed for the determination of Sm, Eu and Yb in water samples by inductively coupled plasma-optical emission spectrometry (ICP-OES after preconcentration on synthesized 5-(4-pyridyl azo-8-quinolinol supported by Borassus flabellifer inflorescence (BFI. The sorbed element was subsequently eluted with 0.4 M HNO3 and the acid eluates were analyzed by ICP-OES. Under the optimal conditions, Sm, Eu and Yb in aqueous samples were concentrated 100-fold. Recoveries were obtained by the proposed method in the range of 98.6 -99.8%. This method was also applied for the analysis of spiked and natural water samples. The results provide strong evidence to support the hypothesis of an adsorption mechanism.

  19. Influence of plasma density and plasma sheath dynamics on the ion implantation by plasma immersion technique

    OpenAIRE

    Ensinger, Wolfgang

    1996-01-01

    Influence of plasma density and plasma sheath dynamics on the ion implantation by plasma immersion technique / B. Rauschenbach ... - In: Nuclear instruments and methods in physics research. B. 113. 1996. S. 266-269

  20. Stirring Unmagnetized Plasma

    CERN Document Server

    Collins, C; Wallace, J; Jara-Almonte, J; Reese, I; Zweibel, E; Forest, C B; 10.1103/PhysRevLett.108.115001

    2012-01-01

    A new concept for spinning unmagnetized plasma is demonstrated experimentally. Plasma is confined by an axisymmetric multi-cusp magnetic field and biased cathodes are used to drive currents and impart a torque in the magnetized edge. Measurements show that flow viscously couples momentum from the magnetized edge (where the plasma viscosity is small) into the unmagnetized core (where the viscosity is large) and that the core rotates as a solid body. To be effective, collisional viscosity must overcome the ion-neutral drag due to charge exchange collisions.

  1. Optical plasma microelectronic devices

    CERN Document Server

    Forati, Ebrahim; Dill, Thyler; Sievenpiper, Dan

    2015-01-01

    The semiconductor channel in conventional microelectronic devices was successfully replaced with an optically triggered gas plasma channel. The combination of DC and laser-induced gas ionizations controls the conductivity of the channel, enabling us to realize different electronic devices such as transistors, switches, modulators, etc. A special micro-scale metasurface was used to enhance the laser-gas interaction, as well as combining it with DC ionization properly. Optical plasma devices benefit form the advantages of plasma/vacuum electronic devices while preserving most of the integrablity of semiconductor based devices.

  2. Radiofrequency power in plasmas

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-31

    This document includes the various communications that were presented at the 11th topical conference on radio frequency power in plasmas which took place in Palm Springs in May 1995. It includes current diffusion studies to assess the non-inductive current deposition profiles, experiments for plasma to reach quickly an equilibrium state, and modelling of electrons in plasma. Some comparison studies also reveal the efficiency of the Quasi-Optical Grill antenna for reactor applications. Finally, a scenario for efficient mode conversion heating in the ion cyclotron range of frequency is presented. Separate abstracts were prepared for the 6 papers in this volume. (TEC).

  3. Determination of tamoxifen and its main metabolites in plasma samples from breast cancer patients by micellar liquid chromatography.

    Science.gov (United States)

    Peris-Vicente, Juan; Ochoa-Aranda, Enrique; Bose, Devasish; Esteve-Romero, Josep

    2015-01-01

    A method was developed for the analysis of tamoxifen and its main derivatives (4-hydroxytamoxifen, N-desmethyl-tamoxifen, tamoxifen-N-oxide and endoxifen) in human plasma, using micellar liquid chromatography coupled with fluorescence detection. Analytes were off-line derivatized by sample UV-irradiation for 20 min to form the photocycled fluorescent derivatives. Then samples were diluted, filtered and directly injected, thus avoiding extraction steps. The analytes were resolved using a mobile phase containing 0.08 M SDS-4.5% butanol at pH 3 running at 1.5 mL/min through a C18 column at 40°C, without interferences from endogenous compounds in plasma. Excitation and emission wavelengths were 260 and 380 nm, respectively. The chromatographic analysis time was less than 40 min. The analytical methodology was validated following the International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) guidelines in terms of: selectivity, linear range (0.3-15 μg/mL), linearity (r(2)>0.999), sensitivity (LOD, 65-80 ng/mL; LOQ, 165-200 ng/mL), intra- and interday accuracy (-12.2-11.5%) and precision (<9.2%) and robustness (<6.3%). The method was used to quantify the tamoxifen and tamoxifen derivatives in several breast cancer patients from a local hospital, in order to study the correlation between the genotype of the patient and the ability to metabolize tamoxifen.

  4. Plasma treatment of bulk niobium surface for superconducting rf cavities: Optimization of the experimental conditions on flat samples

    Directory of Open Access Journals (Sweden)

    M. Rašković

    2010-11-01

    Full Text Available Accelerator performance, in particular the average accelerating field and the cavity quality factor, depends on the physical and chemical characteristics of the superconducting radio-frequency (SRF cavity surface. Plasma based surface modification provides an excellent opportunity to eliminate nonsuperconductive pollutants in the penetration depth region and to remove the mechanically damaged surface layer, which improves the surface roughness. Here we show that the plasma treatment of bulk niobium (Nb presents an alternative surface preparation method to the commonly used buffered chemical polishing and electropolishing methods. We have optimized the experimental conditions in the microwave glow discharge system and their influence on the Nb removal rate on flat samples. We have achieved an etching rate of 1.7  μm/min⁡ using only 3% chlorine in the reactive mixture. Combining a fast etching step with a moderate one, we have improved the surface roughness without exposing the sample surface to the environment. We intend to apply the optimized experimental conditions to the preparation of single cell cavities, pursuing the improvement of their rf performance.

  5. Evaluation of superficially porous and fully porous columns for analysis of drugs in plasma samples by UHPLC-MS/MS.

    Science.gov (United States)

    Acquaro, Vinicius Ricardo; Lanças, Fernando Mauro; Queiroz, Maria Eugênia Costa

    2017-03-24

    This work compares the performance of recently introduced C18 superficially porous columns (four columns) and C18 fully porous columns (two columns), with different particle sizes, during the analysis of drugs in plasma samples by MS/MS detection. The following chromatographic parameters were evaluated for all the columns: reduced plate height (h) vs reduced linear velocity (v), impedance vs v, chromatographic run time vs flow rate (mLmin(-1)), backpressure vs flow rate (mLmin(-1)), resolution, peak capacity, asymmetry, and retention factor. By using DAD detection, hydrophobicity, silanol activity, and metal impurities were also assessed for the columns. The columns with charged surface displayed improved chromatographic efficiency for the drugs in their ionized form. The columns with particles smaller than 2μm (Cortecs 1.6μm, Acquity 1.7μm, and Kinetex 1.7μm) presented higher chromatographic efficiency for the drugs, which were in their partially ionized form. The generated mathematical models were able to predict the backpressure and chromatographic run time at different flow rates for all the columns. Considering the efficiency, impedance, resolution, peak capacity, retention factor, and hydrophobicity, Cortecs 1.6μm and Acquity 1.7μm were the columns that given the best performance during analysis of the target drugs in plasma samples.

  6. Handheld analyzer with on-chip molecularly-imprinted biosensors for electrical detection of propofol in plasma samples.

    Science.gov (United States)

    Hong, Chien-Chong; Lin, Chih-Chung; Hong, Chian-Lang; Lin, Zi-Xiang; Chung, Meng-Hua; Hsieh, Pei-Wen

    2016-12-15

    This paper proposes a novel handheld analyzer with disposable lab-on-a-chip technology for the electrical detection of the anesthetic propofol in human plasma samples for clinical diagnoses. The developed on-chip biosensors are based on the conduction of molecularly imprinted polymers (MIPs) that employ label-free electrical detection techniques. Propofol in total intravenous anesthesia is widely used with a target-controlled infusion system. At present, the methods employed for detecting blood propofol concentrations in hospitals comprise high-performance liquid chromatography and ion mobility spectrometry. These conventional instruments are bulky, expensive, and difficult to access. In this study, we developed a novel plastic microfluidic biochip with an on-chip anesthetic biosensor that was characterized for the rapid detection of propofol concentrations. The experimental results revealed that the response time of the developed propofol biosensors was 25s. The specific binding of an MIP to a nonimprinted polymer (NIP) reached up to 560%. Moreover, the detection limit of the biosensors was 0.1μg/mL, with a linear detection range of 0.1-30μg/mL. The proposed disposable microfluidic biochip with an on-chip anesthetic biosensor using MIPs exhibited excellent performance in the separation and sensing of propofol molecules in the human plasma samples. Compared with large-scale conventional instruments, the developed microfluidic biochips with on-chip MIP biosensors present the advantages of a compact size, high selectivity, low cost, rapid response, and single-step detection.

  7. Plasma Diagnostics and Plasma-Surface Interactions in Inductively Coupled Plasmas

    OpenAIRE

    Titus, Monica Joy

    2010-01-01

    The semiconductor industry's continued trend of manufacturing device features on the nanometer scale requires increased plasma processing control and improved understanding of plasma characteristics and plasma-surface interactions. This dissertation presents a series of experimental results for focus studies conducted in an inductively coupled plasma (ICP) system. First novel "on-wafer" diagnostic tools are characterized and related to plasma characteristics. Second, plasma-polymer interactio...

  8. Plasma Post Oxidation of Plasma Nitrocarburized SKD 61 Steel

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Plasma nitrocarburizing and plasma oxidizing treatments were performed to improve the wear and corrosion resistance of SKD 61 steel. Plasma nitrocarburizing was conducted for 12 h at 540℃ in the nitrogen,hydrogen and methane atmosphere to produce the ε-Fe,2-3(N,C) phase. The compound layer produced by plasma nitrocarburising was predominantly composed of ε-phase, with a small proportion of γ′-Fe4(N,C) phase.The thickness of the compound layer and the diffusion layer are about 10 μm and about 200μm, respectively.Plasma post oxidation was performed on the nitrocarburized samples with various oxygen/hydrogen ratio at constant temperature of 500℃ for 1 h. The very thin magnetite (Fe3O4) layer of 1-2μm in thickness on top of the compound layer was obtained. Anodic polarization test revealed that plasma nitrocarburizing process contributed a significant improvement of corrosion resistance of SKD 61 steel. However, the corrosion characteristics of the nitrocarburized compound layer was deteriorated by oxidation treatment.

  9. Increased levels of HIV RNA detected in samples with viral loads close to the detection limit collected in Plasma Preparation Tubes (PPT).

    Science.gov (United States)

    Griffith, Brigitte P; Mayo, Donald R

    2006-02-01

    The accurate and reliable quantification of HIV RNA is an essential part of the management of HIV infected individuals, and elucidation of factors that may affect HIV RNA measurements, such as the use of Vacutainer Plasma Preparation Tubes (PPT), is crucial. The objective of this study was to determine if plasma samples with viral loads close to the lower limit of the dynamic range of the assay collected in PPT tubes had increased levels of HIV RNA as compared to samples collected in standard EDTA tubes. HIV RNA levels were compared in 112 paired plasma samples collected in PPT and standard EDTA tubes. All samples had been frozen prior to testing. Discrepancies between PPT and EDTA tubes did not occur for samples with high viral loads. However, in samples with viral loads close to the lower limit of the dynamic range, levels of HIV RNA detected were higher in a large proportion of PPT as compared to the corresponding EDTA plasma samples. Forty percent of plasma pairs had no detectable HIV RNA in the EDTA aliquot, but had low levels of HIV RNA in the corresponding PPT aliquot. This prospective study underlines the need for cautious interpretation of small transient viral load changes in samples with values close to the detection limit.

  10. Low gas flow inductively coupled plasma optical emission spectrometry for the analysis of food samples after microwave digestion.

    Science.gov (United States)

    Nowak, Sascha; Gesell, Monika; Holtkamp, Michael; Scheffer, Andy; Sperling, Michael; Karst, Uwe; Buscher, Wolfgang

    2014-11-01

    In this work, the recently introduced low flow inductively coupled plasma optical emission spectrometry (ICP-OES) with a total argon consumption below 0.7 L/min is applied for the first time to the field of food analysis. One goal is the investigation of the performance of this low flow plasma compared to a conventional ICP-OES system when non-aqueous samples with a certain matrix are introduced into the system. For this purpose, arsenic is determined in three different kinds of fish samples. In addition several nutrients (K, Na, Mg, Ca) and trace metals (Co, Cu, Mn, Cd, Pb, Zn, Fe, and Ni) are determined in honey samples (acacia) after microwave digestion. The precision of the measurements is characterized by relative standard deviations (RSD) and compared to the corresponding precision values achieved using the conventional Fassel-type torch of the ICP. To prove the accuracy of the low flow ICP-OES method, the obtained data from honey samples are validated by a conventional ICP-OES. For the measurements concerning arsenic in fish, the low flow ICP-OES values are validated by conventional Fassel-type ICP-OES. Furthermore, a certified reference material was investigated with the low gas flow setup. Limits of detection (LOD), according to the 3σ criterion, were determined to be in the low microgram per liter range for all analytes. Recovery rates in the range of 96-106% were observed for the determined trace metal elements. It was proven that the low gas flow ICP-OES leads to results that are comparable with those obtained with the Fassel-type torch for the analysis of food samples.

  11. The determination of trace element concentrations in fly ash samples using ultrasound-assisted digestion followed with inductively coupled plasma optical emission spectrometry

    OpenAIRE

    Ilander, Aki; Väisänen, Ari

    2009-01-01

    A method of ultrasound-assisted digestion followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of trace element (chromium, copper, lead, nickel, vanadium and zinc) concentrations in fly ash samples was developed. All the measurements were performed in robust plasma conditions. Ultrasound-assisted digestion procedures using digestion solutions of aqua regia and hydrofluoric acid (HF) resulted in recovery rates of over 80% for all the analyte...

  12. An ultrasound-assisted digestion method for the determination of toxic element concentrations in ash samples by inductively coupled plasma optical emission spectrometry

    OpenAIRE

    Ilander, Aki; Väisänen, Ari

    2007-01-01

    method of ultrasound-assisted digestion followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of toxic element concentrations (arsenic, barium, cobalt, copper, lead, nickel, strontium, vanadium and zinc) in ash samples was developed. All the measurements were performed in robust plasma conditions which were tested by measuring the Mg(II) 280.270 nm/Mg(I) 285.213 nm line intensity ratios. The highest line intensity ratios were observed when a...

  13. Gingival plasma cell granuloma

    Directory of Open Access Journals (Sweden)

    Amitkumar B Pandav

    2012-01-01

    Full Text Available Plasma cell granuloma, also known as inflammatory pseudotumor is a tumor-like lesion that manifests primarily in the lungs. But it may occur in various other anatomic locations like orbit, head and neck, liver and rarely in the oral cavity. We here report an exceedingly rare case of gingival plasma cell granuloma in a 58 year old woman who presented with upper gingival polypoidal growth. The histopathological examination revealed a mass composed of proliferation of benign spindle mesenchymal cells in a loose myxoid and fibrocollagenous stroma along with dense infiltrate of chronic inflammatory cells predominantly containing plasma cells. Immunohistochemistry for kappa and lambda light chains showed a polyclonal staining pattern confirming a diagnosis of plasma cell granuloma.

  14. Relativistic spherical plasma waves

    Science.gov (United States)

    Bulanov, S. S.; Maksimchuk, A.; Schroeder, C. B.; Zhidkov, A. G.; Esarey, E.; Leemans, W. P.

    2012-02-01

    Tightly focused laser pulses that diverge or converge in underdense plasma can generate wake waves, having local structures that are spherical waves. Here we study theoretically and numerically relativistic spherical wake waves and their properties, including wave breaking.

  15. Plasma Cell Cheilitis

    Directory of Open Access Journals (Sweden)

    Thami Gurvinder P

    1999-01-01

    Full Text Available A case of plasma cell cheilitis with good response to glucocorticoids, is described for its rarity and probable aetiological correlation with habit of use of nasal snuff is discussed.

  16. Recent advances in hydrophilic interaction chromatography for quantitative analysis of endogenous and pharmaceutical compounds in plasma samples.

    Science.gov (United States)

    Isokawa, Muneki; Kanamori, Takahiro; Funatsu, Takashi; Tsunoda, Makoto

    2014-09-01

    There is an increasing need for new analytical methods that can handle a large number of analytes in complex matrices. Hydrophilic interaction chromatography (HILIC) has recently been demonstrated as an important supplement to reversed-phase liquid chromatography for polar analytes, particularly endogenous compounds. With the increasing popularity of HILIC, progressively more polar phases with diverse functional groups have been developed. In addition, the coupling of HILIC to mass spectrometry offers the advantages of improved sensitivity by employing an organic-rich mobile phase. This article reviews recent applications of HILIC for the analysis of endogenous and pharmaceutical compounds in plasma samples. Furthermore, based on recent studies, we provide a discussion of column selection, sample pretreatment for HILIC analysis, and detection sensitivity.

  17. The plasma scalpel.

    Science.gov (United States)

    Link, W J; Incropera, F P; Glover, J L

    1976-01-01

    The plasma scalpel simultaneously cuts tissue and cauterizes blood vessels measuring 3 mm in diameter with a small, hot (3000 C) gas jet. In animal studies, the amount of hemorrhage has been shown to be less with the plasma scalpel than with steel or electrosurgical scalpels, and incisions have healed without complications. Amount of damaged tissue is limited. Human trials are under way, and the device shows promise as a clinical tool.

  18. Plasma Spray Forming

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    In the course of plasma spray, the plasma jet is comprehensively functioned by such effects as thermal pinch, magnetic pinch and mechanical compression and the flow is jetting at a high speed, the energy is concentrated and its center temperature is so high as to reach upwards of 15 000 ℃ which is capable of melting various kinds of materials inclusive of ceramic, it has a broad applied prospects in the fields of automobile, electronics, telecommunications, medical treatment, air navigation & space navigati...

  19. Plasma-aided manufacturing

    Science.gov (United States)

    Shohet, J. L.

    1993-12-01

    Plasma-aided manufacturing is used for producing new materials with unusual and superior properties, for developing new chemical compounds and processes, for machining, and for altering and refining materials and surfaces. Plasma-aided manufacturing has direct applications to semiconductor fabrication, materials synthesis, welding, lighting, polymers, anti-corrosion coatings, machine tools, metallurgy, electrical and electronics devices, hazardous waste removal, high performance ceramics, and many other items in both the high-technology and the more traditional industries in the United States.

  20. Development of a Fibrinogen-Specific Sandwich Enzyme-Linked Immunosorbent Assay Microarray Assay for Distinguishing Between Blood Plasma and Serum Samples

    Energy Technology Data Exchange (ETDEWEB)

    Gonzales, Rachel M.; Zhang, Qibin; Zangar, Richard C.; Smith, Richard D.; Metz, Thomas O.

    2011-07-01

    We have developed a fibrinogen-specific sandwich ELISA microarray assay for use in qualitatively distinguishing between blood plasma and serum samples. Three capture antibodies, 49D2, HPA001900, and F8512, were evaluated in conjunction with 1D6 as detection antibody, and the data show that 49D2 and, to a lesser extent, F8512 successfully identify previously unknown plasma and serum samples based upon a ~28-fold difference in signal intensity between the sample types. This assay has utility in rapidly identifying previously archived clinical samples with incomplete annotation in a high throughput manner prior to proteomics analyses.

  1. Evaluation of a cost effective in-house method for HIV-1 drug resistance genotyping using plasma samples.

    Directory of Open Access Journals (Sweden)

    Devidas N Chaturbhuj

    Full Text Available OBJECTIVES: Validation of a cost effective in-house method for HIV-1 drug resistance genotyping using plasma samples. DESIGN: The validation includes the establishment of analytical performance characteristics such as accuracy, reproducibility, precision and sensitivity. METHODS: The accuracy was assessed by comparing 26 paired Virological Quality Assessment (VQA proficiency testing panel sequences generated by in-house and ViroSeq Genotyping System 2.0 (Celera Diagnostics, US as a gold standard. The reproducibility and precision were carried out on five samples with five replicates representing multiple HIV-1 subtypes (A, B, C and resistance patterns. The amplification sensitivity was evaluated on HIV-1 positive plasma samples (n = 88 with known viral loads ranges from 1000-1.8 million RNA copies/ml. RESULTS: Comparison of the nucleotide sequences generated by ViroSeq and in-house method showed 99.41±0.46 and 99.68±0.35% mean nucleotide and amino acid identity respectively. Out of 135 Stanford HIVdb listed HIV-1 drug resistance mutations, partial discordance was observed at 15 positions and complete discordance was absent. The reproducibility and precision study showed high nucleotide sequence identities i.e. 99.88±0.10 and 99.82±0.20 respectively. The in-house method showed 100% analytical sensitivity on the samples with HIV-1 viral load >1000 RNA copies/ml. The cost of running the in-house method is only 50% of that for ViroSeq method (112$ vs 300$, thus making it cost effective. CONCLUSIONS: The validated cost effective in-house method may be used to collect surveillance data on the emergence and transmission of HIV-1 drug resistance in resource limited countries. Moreover, the wide applications of a cost effective and validated in-house method for HIV-1 drug resistance testing will facilitate the decision making for the appropriate management of HIV infected patients.

  2. Particle acceleration by plasma

    CERN Document Server

    Ogata, A

    2002-01-01

    Plasma acceleration is carried out by using potential of plasma wave. It is classified by generation method of plasma wave such as the laser wake-field acceleration and the beat wave acceleration. Other method using electron beam is named the plasma wake-field acceleration (or beam wake-field acceleration). In this paper, electron acceleration by laser wake-field in gas plasma, ion source by laser radiation of solid target and nanoion beam generation by one component of plasma in trap are explained. It is an applicable method that ions, which run out from the solid target irradiated by laser, are used as ion source of accelerator. The experimental system using 800 nm laser, 50 mJ pulse energy and 50 fs pulse width was studied. The laser intensity is 4x10 sup 1 sup 6 Wcm sup - sup 2 at the focus. The target film of metal and organic substance film was used. When laser irradiated Al target, two particles generated, in front and backward. It is new fact that the neutral particle was obtained in front, because it...

  3. Direct determination of mercury in cosmetic samples by isotope dilution inductively coupled plasma mass spectrometry after dissolution with formic acid

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Ying; Shi, Zeming; Zong, Qinxia; Wu, Peng; Su, Jing [Sichuan Provincial Key Laboratory of Nuclear Technology in Geology, College of Nuclear Technology and Automation Engineering, Chengdu University of Technology, Chengdu 610059 (China); Liu, Rui, E-mail: liur.ray@gmail.com [Mineral Resources Chemistry Key Laboratory of Sichuan Higher Education Institutions, College of Materials and Chemistry and Chemical Engineering, Chengdu University of Technology, Chengdu 610059 (China)

    2014-02-17

    Graphical abstract: -- Highlights: •Simple, sensitive, and accurate method is established for mercury determination in cosmetics. •The sample preparation procedure is highly simplified. •Isotope dilution efficiently eliminates matrix effect. •First report of using formic acid based method in combination with PVG-ID-ICP MS for mercury quantitation in cosmetics. -- Abstract: A new method was proposed for the accurate determination of mercury in cosmetic samples based on isotopic dilution (ID)-photochemical vapor generation (PVG)-inductively coupled plasma mass spectrometry (ICP MS) measurement. Cosmetic samples were directly dissolved in formic acid solution and subsequently subjected to PVG for the reduction of mercury into vapor species following by ICP MS detection. Therefore, the risks of analyte contamination and loss were avoided. Highly enriched {sup 201}Hg isotopic spike is added to cosmetics and the isotope ratios of {sup 201}Hg/{sup 202}Hg were measured for the quantitation of mercury. With ID calibration, the influences originating from sample matrixes for the determination of mercury in cosmetic samples have been efficiently eliminated. The effects of several experimental parameters, such as the concentration of the formic acid, and the flow rates of carrier gas and sample were investigated. The method provided good reproducibility and the detection limits were found to be 0.6 pg mL{sup −1}. Finally, the developed method was successfully applied for the determination of mercury in six cosmetic samples and a spike test was performed to verify the accuracy of the method.

  4. Plasma Injection Schemes for Laser-Plasma Accelerators

    OpenAIRE

    J. Faure

    2017-01-01

    Plasma injection schemes are crucial for producing high-quality electron beams in laser-plasma accelerators. This article introduces the general concepts of plasma injection. First, a Hamiltonian model for particle trapping and acceleration in plasma waves is introduced; ionization injection and colliding-pulse injection are described in the framework of this Hamiltonian model. We then proceed to consider injection in plasma density gradients.

  5. Determination of lanthanides in rock samples by inductively coupled plasma mass spectrometry using thorium as oxide and hydroxide correction standard

    Science.gov (United States)

    Raut, Narendra M.; Huang, Li-Shing; Aggarwal, Suresh K.; Lin, King-Chuen

    2003-05-01

    Determination of lanthanides by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) using modified mathematical correction method has been studied. Normally, the ICP-MS analysis of middle and heavier lanthanides becomes difficult by severe spectroscopic overlap of M +, MO + or MOH + ions from lighter lanthanides and Ba. A correction method based on a single element oxide yield measurement, is a simple approach to correct for the above spectroscopic overlaps. But the uncertainty in the oxide and hydroxide yields measurement of lanthanides and barium over a long period of time can lead to inaccurate results even under fixed plasma conditions. To correct this, thorium was adopted as an oxide and hydroxide correction standard. Using a ratio of lanthanide oxide yield to thorium oxide yield, the lanthanide correction factors (LCF) were established and incorporated in the mathematical correction scheme. The same factors were also established for hydroxide correction. The proposed modified correction scheme was applied to the determination of lanthanides by ICP-MS from the USGS Standard Rock samples AGV-1 and G-2. The results are in good agreement with the reported values. The method also proved to be useful in isotopic ratio measurement of lanthanides having severe isobaric overlaps.

  6. Comparison of two molecular assays for detection of cytomegalovirus DNA in whole blood and plasma samples from transplant recipients.

    Science.gov (United States)

    Costa, Cristina; Sidoti, Francesca; Mantovani, Samantha; Gregori, Gabriella; Proietti, Alex; Ghisetti, Valeria; Cavallo, Rossana

    2016-07-01

    In immunosuppressed patients, pre-emptive therapy and a strict follow-up of CMV infection are the standard of care for the prevention of CMV disease. Several real-time PCR assays for CMV DNA quantification on whole blood (WB) and plasma (PL) are commercially available. This study compared and correlated CMV viral loads obtained by the Cobas AmpliPrep/Cobas TaqMan (CAP/CTM) platform on plasma specimens with those obtained on corresponding whole blood specimens by the real-time PCR assay (ELITe MGB-CMV) in 185 sequential samples from 41 immunosuppressed patients. Correlation between the two assays was good. Kinetics of CMV DNA within the same patient was similar, but PL viral load was constantly 1 log lower than WB. In patients under antiviral therapy, low level of CMV DNA persisted in WB, while it was absent in PL. The good correlation between CMV DNA detected on both PL and WB supports the reliability of the two matrices for viral monitoring and the therapeutic management of CMV infection. Nevertheless, due to significant quantification differences between PL and WB CMV DNA, the same biological specimen should be used for a sequential and reliable follow-up of patients at high risk of CMV infection.

  7. Plasma surface modification of polymers

    Science.gov (United States)

    Hirotsu, T.

    1980-01-01

    Thin plasma polymerization films are discussed from the viewpoint of simplicity in production stages. The application of selective, absorbent films and films used in selective permeability was tested. The types of surface modification of polymers discussed are: (1) plasma etching, (2) surface coating by plasma polymerized thin films, and (3) plasma activation surface graft polymerization.

  8. Plasma-based accelerator structures

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, Carl B. [Univ. of California, Berkeley, CA (United States)

    1999-12-01

    Plasma-based accelerators have the ability to sustain extremely large accelerating gradients, with possible high-energy physics applications. This dissertation further develops the theory of plasma-based accelerators by addressing three topics: the performance of a hollow plasma channel as an accelerating structure, the generation of ultrashort electron bunches, and the propagation of laser pulses is underdense plasmas.

  9. Determination of cadmium, mercury and lead in coal fly ash by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry

    Science.gov (United States)

    Liao, Hsien-Chung; Jiang, Shiuh-Jen

    1999-08-01

    Ultrasonic slurry sampling electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry (USS-ETV-ID-ICP-MS) has been applied to the determination of Cd, Hg and Pb in coal fly ash samples. Thioacetamide (TAC) was used as the modifier. Since the sensitivities of the elements studied in coal fly ash slurry and aqueous solution were quite different, isotope dilution method was used for the determination of Cd, Hg and Pb in these coal fly ash samples. The isotope ratios of each element were calculated from the peak areas of each injection peak. This method has been applied to the determination of Cd, Hg and Pb in NIST SRM 1633a coal fly ash reference material and a coal fly ash sample collected from Kaohsiung area. Analysis results of reference sample NIST SRM 1633a coal fly ash agreed satisfactorily with the certified values. The other sample determined by isotope dilution and method of standard additions was agreed satisfactorily. Precision was better than 6% for most of the determinations and accuracy was better than 4% with the USS-ETV-ID-ICP-MS method. Detection limits estimated from standard addition curves were in the range of 24-58, 6-28 and 108-110 ng g-1 for Cd, Hg and Pb, respectively.

  10. Multistage plasma initiation process by pulsed CO2 laser irradiation of a Ti sample in an ambient gas (He, Ar, or N2)

    Science.gov (United States)

    Hermann, J.; Boulmer-Leborgne, C.; Mihailescu, I. N.; Dubreuil, B.

    1993-02-01

    New experimental results are reported on plasma initiation in front of a titanium sample irradiated by ir (λ=10.6 μm) laser pulses in an ambient gas (He, Ar, and N2) at pressures ranging from several Torr up to the atmosphere. The plasma is studied by space- and time-resolved emission spectroscopy, while sample vaporization is probed by laser-induced fluorescence spectroscopy. Threshold laser intensities leading to the formation of a plasma in the vapor and in the ambient gases are determined. Experimental results support the model of a vaporization mechanism for the plasma initiation (vaporization-initiated plasma breakdown). The plasma initiation is described by simple numerical criteria based on a two-stage process. Theoretical predictions are found to be in a reasonable agreement with the experiment. This study provides also a clear explanation of the influence of the ambient gas on the laser beam-metal surface energy transfer. Laser irradiation always causes an important vaporization when performed in He, while in the case of Ar or N2, the interaction is reduced in heating and vaporization of some surface defects and impurities.

  11. Plasma accelerator experiments in Yugoslavia

    Science.gov (United States)

    Purić, J.; Astashynski, V. M.; Kuraica, M. M.; Dojčinovié, I. P.

    2002-12-01

    An overview is given of the results obtained in the Plasma Accelerator Experiments in Belgrade, using quasi-stationary high current plasma accelerators constructed within the framework of the Yugoslavia-Belarus Joint Project. So far, the following plasma accelerators have been realized: Magnetoplasma Compressor type (MPC); MPC Yu type; one stage Erosive Plasma Dynamic System (EPDS) and, in final stage of construction two stage Quasi-Stationary High Current Plasma Accelerator (QHPA).

  12. UPLC-MS/MS assay of riluzole in human plasma and cerebrospinal fluid (CSF): Application in samples from spinal cord injured patients.

    Science.gov (United States)

    Sarkar, Mahua; Grossman, Robert G; Toups, Elizabeth G; Chow, Diana S-L

    2017-09-01

    In the present study, a sensitive and robust LC-MS/MS method has been developed and validated for the quantification of riluzole in human plasma and cerebrospinal fluid (CSF) in clinical samples from patients with spinal cord injury (SCI). Riluzole and its labeled internal standard (IS) were isolated from plasma and CSF by liquid-liquid extraction using ethyl acetate. Riluzole (m/z 235→166) and IS (m/z 238→169) were detected by electrospray ionization (ESI) using multiple reaction monitoring (MRM) in a positive mode. The assay was linear in the concentration range of 0.5 (LLOQ, signal/noise ratio>10)-800ng/ml in plasma, and 1.0 (LLOQ)-800ng/ml in CSF samples. The intra- and inter-day accuracy in plasma were 94.2-110.0% and 97.8-102.0%, respectively, and those in CSF were 87.6-105.1% and 91.9-98.8%, respectively. The intra- and inter-day precision were 2.2-7.2% and 4.0-9.1%, respectively, in plasma, and 1.4-14.1% and 2.6-11.5%, respectively in CSF. Matrix effect was negligible from both matrices with signal percentages of 97.6-100.6% in plasma and 99.4-106.4% in CSF. The recoveries were >75% in plasma, >84% in CSF with low protein (53.9mg/dl), and >68% in CSF with high protein (348.2mg/dl). This method was successfully applied to quantify riluzole concentrations in plasma and CSF from patients with SCI. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Plasma transport in the Scrape-off-Layer of magnetically confined plasma and the plasma exhaust

    DEFF Research Database (Denmark)

    Rasmussen, Jens Juul; Naulin, Volker; Nielsen, Anders Henry

    An overview of the plasma dynamics in the Scrape-off-Layer (SOL) of magnetically confined plasma is presented. The SOL is the exhaust channel of the warm plasma from the core, and the understanding of the SOL plasma dynamics is one of the key issues in contemporary fusion research. It is essential...

  14. Effect of storage conditions on prothrombin time, activated partial thromboplastin time and fibrinogen concentration on canine plasma samples

    Science.gov (United States)

    Casella, Stefania; Giannetto, Claudia; Giudice, Elisabetta

    2010-01-01

    The present study was to assess the effect of storage conditions on prothrombin time (PT), activated partial thromboplastin time (aPTT) and fibrinogen concentration in blood samples of healthy dogs. Thirty-five dogs of various breeds were included in the study. Citrated blood samples were obtained and plasma was divided into four aliquots to assess selected clotting parameters by means of a coagulometer. The first aliquot was analysed within 1 h after collection, while the remaining 3 were stored at 8℃ for 4, 8 and 24 h, respectively. One-way repeated measures analysis of variance documented a significant decreasing effect on PT at 24 h compared to 8 h and on fibrinogen concentration after 8 and 24 h compared to sampling time and at 4 and 24 h compared to 8 h post sampling. In conclusion, the results of this study indicate that only fibrinogen appears prone to significant decrease. In fact, aPTT is not substantially affected by refrigeration for at least 24 h post sampling and PT showed a statistical difference that does not necessary indicate biological significance as the results obtained were within reference intervals for the dog. PMID:20458152

  15. Determination of dimethyltryptamine and β-carbolines (ayahuasca alkaloids) in plasma samples by LC-MS/MS.

    Science.gov (United States)

    Oliveira, Carolina Dizioli Rodrigues; Okai, Guilherme Gonçalves; da Costa, José Luiz; de Almeida, Rafael Menck; Oliveira-Silva, Diogo; Yonamine, Mauricio

    2012-07-01

    Ayahuasca is a psychoactive plant beverage originally used by indigenous people throughout the Amazon Basin, long before its modern use by syncretic religious groups established in Brazil, the USA and European countries. The objective of this study was to develop a method for quantification of dimethyltryptamine and β-carbolines in human plasma samples. The analytes were extracted by means of C18 cartridges and injected into LC-MS/MS, operated in positive ion mode and multiple reaction monitoring. The LOQs obtained for all analytes were below 0.5 ng/ml. By using the weighted least squares linear regression, the accuracy of the analytical method was improved at the lower end of the calibration curve (from 0.5 to 100 ng/ml; r(2)> 0.98). The method proved to be simple, rapid and useful to estimate administered doses for further pharmacological and toxicological investigations of ayahuasca exposure.

  16. Intelligent Analysis of Samples by Semiquantitative Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) Technique: A Review.

    Science.gov (United States)

    Krzciuk, Karina

    2016-07-03

    Inductively coupled plasma-mass spectrometry (ICP-MS) is a popular and routine analytical method that has been used for determination of trace elements since the 1980s. It provides fast quantitative analysis and allows the determination of more than 70 elements with good accuracy and very low detection limits, but requires an intricate calibration procedure. In analyses of samples for which very low detection limits are not required a semiquantitative ICP-MS analysis mode can be used. This approach is more time- and cost-effective, and it uses a simple calibration procedure. This article presents a critical review of the semiquantitative (SQ) mode of ICP-MS and describes current and future applications of SQ analysis.

  17. A New Liquid Chromatography-Tandem Mass Spectrometry Method for Determination of Bisoprolol in Human Plasma Samples

    Directory of Open Access Journals (Sweden)

    Gabriela Peste

    2009-01-01

    Full Text Available Liquid chromatography (LC coupled with mass spectrometry (MS detection is one of the most powerful analytical tools for organic compound analysis. The advantages of using LC/MS methods over HPLC methods include: selectivity, chromatographic integrity, peak assignment, structural information, and rapid method development. In this paper, a new liquid chromatography-tandem mass spectrometry (LC-MS/MS method has been developed and validated for the determination of bisoprolol in human plasma samples, using metoprolol as internal standard and liquid-liquid extraction procedure. The assay has proven to be sensitive, specific and reproducible, suitable to determine the bisoprolol concentration, following a single oral administration of a 10 mg bisoprolol tablet in 22 healthy volunteers, in the bioequivalence study of Bisoprolol 10 mg coated tablets, produced by Antibiotice S.A. versus Concor 10 mg, produced by Merck.

  18. Turbulent complex (dusty) plasma

    Science.gov (United States)

    Zhdanov, Sergey; Schwabe, Mierk

    2017-04-01

    As a paradigm of complex system dynamics, solid particles immersed into a weakly ionized plasma, so called complex (dusty) plasmas, were (and continue to be) a subject of many detailed studies. Special types of dynamical activity have been registered, in particular, spontaneous pairing, entanglement and cooperative action of a great number of particles resulting in formation of vortices, self-propelling, tunneling, and turbulent movements. In the size domain of 1-10 mkm normally used in experiments with complex plasmas, the characteristic dynamic time-scale is of the order of 0.01-0.1 s, and these particles can be visualized individually in real time, providing an atomistic (kinetic) level of investigations. The low-R turbulent flow induced either by the instability in a complex plasma cloud or formed behind a projectile passing through the cloud is a typical scenario. Our simulations showed formation of a fully developed system of vortices and demonstrated that the velocity structure functions scale very close to the theoretical predictions. As an important element of self-organization, cooperative and turbulent particle motions are present in many physical, astrophysical, and biological systems. Therefore, experiments with turbulent wakes and turbulent complex plasma oscillations are a promising mean to observe and study in detail the anomalous transport on the level of individual particles.

  19. Plasma treatment of onychomycosis

    Science.gov (United States)

    Xiong, Zilan; Roe, Jeff; Grammer, Tim; Him, Yeon-Ho; Graves, David B.

    2015-09-01

    Onychomycosis or fungal infection of the toenail or fingernail is a common affliction. Approximately 10% of the world's adult population is estimated to suffer from onychomycosis. Current treatment options such as topical creams, oral drugs, or laser treatments are generally limited by a variety of problems. We present results for an alternative onychomycosis treatment scheme using atmospheric pressure cold air plasmas. Using thinned cow hoof as a model nail material, we tested the ability of various plasma sources to act through the model nail to eradicate either bacteria or fungus deposited on the opposite side. Following 20 minute exposure to a surface microdischarge (SMD) device operating in room air, we observed a ~ 2 log reduction of E. coli. A similar result was obtained against T. rubrum after 45 min plasma treatment. NOx species concentration penetrating through the model nail as well as uptake into the nail were measured as a function of nail thickness. We propose that these plasma-generated species, or perhaps their reaction products, are responsible for at least part of the observed anti-microbial effect. We also explore the use of ultraviolet light acting in synergy with plasma-generated chemical species.

  20. Plasma coal reprocessing

    Science.gov (United States)

    Messerle, V. E.; Ustimenko, A. B.

    2013-12-01

    Results of many years of investigations of plasma-chemical technologies for pyrolysis, hydrogenation, thermochemical preparation for combustion, gasification, and complex reprocessing of solid fuels and hydrocarbon gas cracking are represented. Application of these technologies for obtaining the desired products (hydrogen, industrial carbon, synthesis gas, valuable components of the mineral mass of coal) corresponds to modern ecological and economical requirements to the power engineering, metallurgy, and chemical industry. Plasma fuel utilization technologies are characterized by the short-term residence of reagents within a reactor and the high degree of the conversion of source substances into the desired products without catalyst application. The thermochemical preparation of the fuel to combustion is realized in a plasma-fuel system presenting a reaction chamber with a plasmatron; and the remaining plasma fuel utilization technologies, in a combined plasma-chemical reactor with a nominal power of 100 kW, whose zone of the heat release from an electric arc is joined with the chemical reaction zone.

  1. Alcohol and plasma triglycerides.

    Science.gov (United States)

    Klop, Boudewijn; do Rego, Ana Torres; Cabezas, Manuel Castro

    2013-08-01

    This study reviews recent developments concerning the effects of alcohol on plasma triglycerides. The focus will be on population, intervention and metabolic studies with respect to alcohol and plasma triglycerides. Alcohol consumption and fat ingestion are closely associated and stimulated by each other via hypothalamic signals and by an elevated cephalic response. A J-shaped relationship between alcohol intake and plasma triglycerides has been described. A normal body weight, polyphenols in red wine and specific polymorphisms of the apolipoprotein A-V and apolipoprotein C-III genes may protect against alcohol-associated hypertriglyceridemia. In contrast, obesity exaggerates alcohol-associated hypertriglyceridemia and therefore the risk of pancreatitis. High alcohol intake remains harmful since it is associated with elevated plasma triglycerides, but also with cardiovascular disease, alcoholic fatty liver disease and the development of pancreatitis. Alcohol-induced hypertriglyceridemia is due to increased very-low-density lipoprotein secretion, impaired lipolysis and increased free fatty acid fluxes from adipose tissue to the liver. However, light to moderate alcohol consumption may be associated with decreased plasma triglycerides, probably determined by the type of alcoholic beverage consumed, genetic polymorphisms and lifestyle factors. Nevertheless, patients should be advised to reduce or stop alcohol consumption in case of hypertriglyceridemia.

  2. Plasma, blood and liver tissue sample preparation methods for the separate quantification of liposomal-encapsulated prednisolone phosphate and non-encapsulated prednisolone

    NARCIS (Netherlands)

    Smits, Evelien A W; Soetekouw, José A; Bakker, Peter F A; Baijens, Bart J H; Vromans, Herman

    2015-01-01

    Besides the development of sample preparation methods for the determination of separate liposomal-encapsulated prednisolone phosphate and non-encapsulated prednisolone concentrations in murine plasma and blood, this article also presents the first description of an accurate sample preparation method

  3. Determination of metformin in mouse, rat, dog and human plasma samples by laser diode thermal desorption/atmospheric pressure chemical ionization tandem mass spectrometry.

    Science.gov (United States)

    Swales, John G; Gallagher, Richard; Peter, Raimund M

    2010-11-02

    A simple, rapid and robust high-throughput assay for the quantitative analysis of metformin in plasma from different species using laser diode thermal desorption interfaced with atmospheric chemical pressure ionization tandem mass spectrometry (LDTD-APCI-MSMS) was developed for use in a pharmaceutical discovery environment. In order to minimize sample preparation a generic protein precipitation method was used to extract metformin from the plasma. Laser diode thermal desorption is a relatively new sample introduction method, the optimization of the instrumental parameters are presented. The method was successfully applied to spiked mouse, rat, dog and human plasma samples and was subsequently used to determine the oral pharmacokinetics of metformin after dosing to male rats in order to support drug discovery projects. The deviations for intra-assay accuracy and precision across the four species were less than 30% at all calibration and quality control levels.

  4. A rapid, accurate and robust particle-based assay for the simultaneous screening of plasma samples for the presence of five different anti-cytokine autoantibodies

    DEFF Research Database (Denmark)

    Guldager, Daniel Kring Rasmussen; von Stemann, Jakob Hjorth; Larsen, Rune

    2015-01-01

    PURPOSE: To establish and validate a rapid, cost-effective and accurate screening assay for the simultaneous testing of human naturally occurring anti-cytokine autoantibodies (c-aAb) targeting interleukin-1α (IL-1α), interleukin-6 (IL-6), interleukin-10 (IL-10), granulocyte-macrophage colony...... plasma samples and pooled normal immunoglobulin preparations were used to validate the assay. Plasma samples from 98 transfusion recipients, half of whom presented with febrile reactions, were tested by the assay. RESULTS: The assay detected specific and saturable immunoglobulin G (IgG) binding to each...... cytokine autoantibodies quantities in the negative plasma samples ranged between 80% and 125%. The analytical intra- and inter-assay variations were 4% and 11%, respectively. Varying c-aAb levels were detectable in the transfusion recipients. There was no difference in c-aAb frequency between the patients...

  5. Direct determination of sulfur species in coals from the Argonne premium sample program by solid sampling electrothermal vaporization inductively coupled plasma optical emission spectrometry.

    Science.gov (United States)

    Bauer, Daniela; Vogt, Thomas; Klinger, Mathias; Masset, Patrick Joseph; Otto, Matthias

    2014-10-21

    A new direct solid sampling method for speciation of sulfur in coals by electrothermal vaporization inductively coupled plasma optical emission spectrometry (ETV-ICP OES) is presented. On the basis of the controlled thermal decomposition of coal in an argon atmosphere, it is possible to determine the different sulfur species in addition to elemental sulfur in coals. For the assignment of the obtained peaks from the sulfur transient emission signal, several analytical techniques (reflected light microscopy, scanning electron microscopy with energy dispersive X-ray spectroscopy and X-ray diffraction) were used. The developed direct solid sampling method enables a good accuracy (relative standard deviation ≤ 6%), precision and was applied to determine the sulfur forms in the Argonne premium coals, varying in rank. The generated method is time- and cost-effective and well suited for the fast characterization of sulfur species in coal. It can be automated to a large extent and is applicable for process-accompanying analyses.

  6. Plasma diagnostics in plasma processing for nanotechnology and nanolevel chemistry

    Directory of Open Access Journals (Sweden)

    Hiroshi Akatsuka

    2004-01-01

    Full Text Available The author reviews the role of various plasma diagnostics in plasma processing for nanotechnology, and points out some essential methods of spectroscopic methods to diagnose plasmas for nanoprocessing. Two experimental examples are discussed between the characteristics of nanomaterials and plasma parameters. One is measurement of rotation temperature in processing of carbon nanotube. The other is that of vibrational temperature in surface nitriding of titanium by nitrogen plasma processing. We summarize what to measure and how to measure them from the technical viewpoint of plasma diagnostics.

  7. Optical plasma torch electron bunch generation in plasma wakefield accelerators

    Directory of Open Access Journals (Sweden)

    G. Wittig

    2015-08-01

    Full Text Available A novel, flexible method of witness electron bunch generation in plasma wakefield accelerators is described. A quasistationary plasma region is ignited by a focused laser pulse prior to the arrival of the plasma wave. This localized, shapeable optical plasma torch causes a strong distortion of the plasma blowout during passage of the electron driver bunch, leading to collective alteration of plasma electron trajectories and to controlled injection. This optically steered injection is more flexible and faster when compared to hydrodynamically controlled gas density transition injection methods.

  8. Determination of protein carbonyls in plasma, cell extracts, tissue homogenates, isolated proteins: Focus on sample preparation and derivatization conditions.

    Science.gov (United States)

    Weber, Daniela; Davies, Michael J; Grune, Tilman

    2015-08-01

    Protein oxidation is involved in regulatory physiological events as well as in damage to tissues and is thought to play a key role in the pathophysiology of diseases and in the aging process. Protein-bound carbonyls represent a marker of global protein oxidation, as they are generated by multiple different reactive oxygen species in blood, tissues and cells. Sample preparation and stabilization are key steps in the accurate quantification of oxidation-related products and examination of physiological/pathological processes. This review therefore focuses on the sample preparation processes used in the most relevant methods to detect protein carbonyls after derivatization with 2,4-dinitrophenylhydrazine with an emphasis on measurement in plasma, cells, organ homogenates, isolated proteins and organelles. Sample preparation, derivatization conditions and protein handling are presented for the spectrophotometric and HPLC method as well as for immunoblotting and ELISA. An extensive overview covering these methods in previously published articles is given for researchers who plan to measure protein carbonyls in different samples.

  9. Comparison of selenium determination in liver samples by atomic absorption spectroscopy and inductively coupled plasma-mass spectrometry.

    Science.gov (United States)

    Miksa, Irina Rudik; Buckley, Carol L; Carpenter, Nancy P; Poppenga, Robert H

    2005-07-01

    Selenium (Se) is an essential trace element that is often deficient in the natural diets of domestic animal species. The measurement of Se in whole blood or liver is the most accurate way to assess Se status for diagnostic purposes. This study was conducted to compare hydride generation atomic absorption spectroscopy (HG-AAS) with inductively coupled plasma-mass spectrometry (ICP-MS) for the detection and quantification of Se in liver samples. Sample digestion was accomplished with magnesium nitrate and nitric acid for HG-AAS and ICP-MS, respectively. The ICP-MS detection was optimized for 82Se with yttrium used as the internal standard and resulted in a method detection limit of 0.12 microg/g. Selenium was quantified by both methods in 310 samples from a variety of species that were submitted to the Toxicology Laboratory at New Bolton Center (Kennett Square, PA) for routine diagnostic testing. Paired measurements for each sample were evaluated by a mean difference plot method. Limits of agreement were used to describe the maximum differences likely to occur between the 2 methods. Results suggest that under the specified conditions ICP-MS can be reliably used in place of AAS for quantitation of tissue Se at or below 2 microg/g to differentiate between adequate and deficient liver Se concentrations.

  10. Comparison of laser ablation and dried solution aerosol as sampling systems in inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Coedo, A G; Padilla, I; Dorado, M T

    2004-12-01

    This paper describes a study designed to determine the possibility of using a dried aerosol solution for calibration in laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The relative sensitivities of tested materials mobilized by laser ablation and by aqueous nebulization were established, and the experimentally determined relative sensitivity factors (RSFs) were used in conjunction with aqueous calibration for the analysis of solid steel samples. To such a purpose a set of CRM carbon steel samples (SS-451/1 to SS-460/1) were sampled into an ICP-MS instrument by solution nebulization using a microconcentric nebulizer with membrane desolvating (D-MCN) and by laser ablation (LA). Both systems were applied with the same ICP-MS operating parameters and the analyte signals were compared. The RSF (desolvated aerosol response/ablated solid response) values were close to 1 for the analytes Cr, Ni, Co, V, and W, about 1.3 for Mo, and 1.7 for As, P, and Mn. Complementary tests were carried out using CRM SS-455/1 as a solid standard for one-point calibration, applying LAMTRACE software for data reduction and quantification. The analytical results are in good agreement with the certified values in all cases, showing that the applicability of dried aerosol solutions is a good alternative calibration system for laser ablation sampling.

  11. Macro- and micro-element analysis in milk samples by inductively coupled plasma-optical emission spectrometry

    Directory of Open Access Journals (Sweden)

    Petrović Sanja M.

    2016-01-01

    Full Text Available The paper describes the determination of Ag, Al, B, Ba, Bi, Ca, Cd, Co, Cr, Cu, Fe, Ga, In, K, Li, Mg, Mn, Na, Ni, Pb, Sr, Tl and Zn, as well as total fat content of milk samples, originated from different sources. The analyzed milk samples were: human milk, fresh cow milk, pasteurized cow milk from a local market, and reconstituted powder milk. The milk samples were obtained from Jablanica District (Serbia territory. Preparation of samples for macro- and micro-analyses was done by wet digestion. Concentrations of the elements after digestion were determined by inductively coupled plasma optical emission spectrometry (ICP-OES. Total fat content of milk samples was determinate by the Weibull and Stoldt method. The results showed that potassium and calcium concentrations were the highest in all samples: 1840.64 - 2993.26 mg/L and 456.05 - 1318.08 mg/L, respectively. Of all heavy metals from the examined milk samples (copper, zinc, manganese, nickel, cadmium, and lead, the most common were zinc and copper, with approximately similar content in the range of 5 - 12 mg/l, while cadmium nickel and manganese were not detected at all. Samples of fresh cow milk and human milk showed the highest fat content of 3.6 and 4.2 %, respectively. Results for total fat and macro- and micro-analyses showed that fresh cow milk has the highest contents of fat and calcium, making it the most nutritious. [Projekat Ministarstva nauke Republike Srbije, br. TR 34012

  12. Conditional Eddies in Plasma Turbulence

    DEFF Research Database (Denmark)

    Johnsen, Helene; Pécseli, Hans; Trulsen, J.

    1986-01-01

    Conditional structures, or eddies, in turbulent flows are discussed with special attention to electrostatic turbulence in plasmas. The potential variation of these eddies is obtained by sampling the fluctuations only when a certain condition is satisfied in a reference point. The resulting...

  13. Plasma rico en plaquetas Platelet -rich plasma

    Directory of Open Access Journals (Sweden)

    J. González Lagunas

    2006-04-01

    Full Text Available El Plasma Rico en Plaquetas es una suspensión concentrada de la sangre centrifugada que contiene elevadas concentraciones de trombocitos. Durante los últimos años, este producto ha aparecido de forma repetida en publicaciones científicas y en medios de comunicación generales como un producto que por sus características induce la curación y regeneración de los tejidos. La premisa de su uso es que las elevadas concentraciones de plaquetas en el PRP, liberan cantidades significativas de factores de crecimiento. En este artículo se van a recoger las evidencias científicas que se han presentado en la literatura médica con respecto al PRP y a la curación ósea, así como las diferentes aplicaciones clínicas que se han sugerido.Platelet-rich plasma is a by-product of centrifuged whole blood that contains high levels of thrombocytes. In the last decade, scientific and media interest has been generated by this product that apparently has the capacity of inducing and promoting tissue healing and regeneration. The premise of its use is that the large number of platelets in PRP release significant amounts of growth factors. In this paper, a critical review of the medical literature regarding PRP and bone healing will be presented. Also, the suggested clinical applications of the product will be addressed.

  14. pH adjustment of human blood plasma prior to bioanalytical sample preparation

    NARCIS (Netherlands)

    Hendriks, G.; Uges, D. R. A.; Franke, J. P.

    2008-01-01

    pH adjustment in bioanalytical sample preparation concerning ionisable compounds is one of the most common sample treatments. This is often done by mixing an aliquot of the sample with a proper buffer adjusted to the proposed pH. The pH of the resulting mixture however, does not necessarily have to

  15. Plasma Colloquium Travel Grant Program

    Energy Technology Data Exchange (ETDEWEB)

    Hazeltine, R.D.

    1998-09-14

    OAK B188 Plasma Colloquium Travel Grant Program. The purpose of the Travel Grant Program is to increase the awareness of plasma research. The new results and techniques of plasma research in fusion plasmas, plasma processing space plasmas, basic plasma science, etc, have broad applicability throughout science. The benefits of these results are limited by the relatively low awareness and appreciation of plasma research in the larger scientific community. Whereas spontaneous interactions between plasma scientists and other scientists are useful, a focused effort in education and outreach to other scientists is efficient and is needed. The academic scientific community is the initial focus of this effort, since that permits access to a broad cross-section of scientists and future scientists including undergraduates, graduate students, faculty, and research staff.

  16. Quantum Plasmas An Hydrodynamic Approach

    CERN Document Server

    Haas, Fernando

    2011-01-01

    This book provides an overview of the basic concepts and new methods in the emerging scientific area known as quantum plasmas. In the near future, quantum effects in plasmas will be unavoidable, particularly in high density scenarios such as those in the next-generation intense laser-solid density plasma experiment or in compact astrophysics objects. Currently, plasmas are in the forefront of many intriguing questions around the transition from microscopic to macroscopic modeling of charged particle systems. Quantum Plasmas: an Hydrodynamic Approach is devoted to the quantum hydrodynamic model paradigm, which, unlike straight quantum kinetic theory, is much more amenable to investigate the nonlinear realm of quantum plasmas. The reader will have a step-by-step construction of the quantum hydrodynamic method applied to plasmas. The book is intended for specialists in classical plasma physics interested in methods of quantum plasma theory, as well as scientists interested in common aspects of two major areas of...

  17. Plasma cell leukemia

    DEFF Research Database (Denmark)

    Fernández de Larrea, C; Kyle, R A; Durie, B G M

    2013-01-01

    Plasma cell leukemia (PCL) is a rare and aggressive variant of myeloma characterized by the presence of circulating plasma cells. It is classified as either primary PCL occurring at diagnosis or as secondary PCL in patients with relapsed/refractory myeloma. Primary PCL is a distinct clinic......-pathological entity with different cytogenetic and molecular findings. The clinical course is aggressive with short remissions and survival duration. The diagnosis is based upon the percentage (≥ 20%) and absolute number (≥ 2 × 10(9)/l) of plasma cells in the peripheral blood. It is proposed that the thresholds...... regimens and bortezomib-based regimens are recommended followed by high-dose therapy with autologous stem cell transplantation if feasible. Allogeneic transplantation can be considered in younger patients. Prospective multicenter studies are required to provide revised definitions and better understanding...

  18. Photon kinetics in plasmas

    Directory of Open Access Journals (Sweden)

    V.G. Morozov

    2009-01-01

    Full Text Available We present a kinetic theory of radiative processes in many-component plasmas with relativistic electrons and nonrelativistic heavy particles. Using the non-equilibrium Green's function technique in many-particle QED, we show that the transverse field correlation functions can be naturally decomposed into sharply peaked (non-Lorentzian parts that describe resonant (propagating photons and off-shell parts corresponding to virtual photons in the medium. Analogous decompositions are obtained for the longitudinal field correlation functions and the correlation functions of relativistic electrons. We derive a kinetic equation for the resonant photons with a finite spectral width and show that the off-shell parts of the particle and field correlation functions are essential to calculate the local radiating power in plasmas and recover the results of vacuum QED. The plasma effects on radiative processes are discussed.

  19. Large area plasma source

    Science.gov (United States)

    Foster, John (Inventor); Patterson, Michael (Inventor)

    2008-01-01

    An all permanent magnet Electron Cyclotron Resonance, large diameter (e.g., 40 cm) plasma source suitable for ion/plasma processing or electric propulsion, is capable of producing uniform ion current densities at its exit plane at very low power (e.g., below 200 W), and is electrodeless to avoid sputtering or contamination issues. Microwave input power is efficiently coupled with an ionizing gas without using a dielectric microwave window and without developing a throat plasma by providing a ferromagnetic cylindrical chamber wall with a conical end narrowing to an axial entrance hole for microwaves supplied on-axis from an open-ended waveguide. Permanent magnet rings are attached inside the wall with alternating polarities against the wall. An entrance magnet ring surrounding the entrance hole has a ferromagnetic pole piece that extends into the chamber from the entrance hole to a continuing second face that extends radially across an inner pole of the entrance magnet ring.

  20. Amygdala kindling elevates plasma vasopressin.

    Science.gov (United States)

    Greenwood, R S; Meeker, R B; Hayward, J N

    1991-01-01

    Acute and chronic effects of epilepsy on endocrine function are known to occur in humans with partial seizures of limbic origin and in animals with limbic kindled seizures. The amygdala, a component of the limbic system, has dense hypothalamic connections and amygdala stimulation in monkeys and cats result in vasopressin release. In the present study we sought to determine if amygdala stimulation in the rats results in an immediate acute release of vasopressin and to determine if acute or chronic changes occur in vasopressin release in the fully kindled animal. Plasma vasopressin, osmolality and hematocrit were measured in blood samples drawn from rats with implanted venous catheters before and after stimulation and at different stages of kindling. Low-frequency (15 Hz) electrical stimulation of the amygdala was followed by an immediate, 3-fold increase in plasma vasopressin concentration. Moreover, although the 60 Hz kindling stimulus did not result in a significant immediate rise in plasma vasopressin prior to kindling, after kindling to stage 5 seizures the 60 Hz kindling stimulus resulted in seizures and a significant immediate rise in plasma vasopressin. In addition, we found that kindling was followed by a significant, though modest, rise in the resting plasma vasopressin without an accompanying change in osmolality or hematocrit. We conclude that kindling results in a persistent alteration in the vasopressinergic neuroendocrine system.

  1. Development of a high throughput 96-well plate sample preparation method for the determination of trileptal (oxcarbazepine) and its metabolites in human plasma.

    Science.gov (United States)

    Souppart, C; Decherf, M; Humbert, H; Maurer, G

    2001-10-05

    A high throughput preparation method for the determination of trileptal (oxcarbazepine, OXC) and its mono (MHD) and dihydroxy (DHD) metabolites in human plasma, using 96-well plate technology, has been developed and validated according to international regulatory requirements. Preparation of plasma samples (50 microl) containing the compounds to be analysed involved solid-phase extraction (SPE) on Empore C18 96-well SPE plates. Eluates from the plate were injected onto a reversed-phase column (Hypersil C18,3 microm) with UV detection at 210 nm. Detector response was linear over the ranges 0.2-10, 0.1-200 and 0.1-20 micromol/l, for OXC, MHD and DHD, respectively, with relative standard deviations from 1 to 10% and mean accuracies within 4% of the nominal values (number of standard curves=3 in duplicate). The limits of quantitation were 0.2, 0.1 and 0.1 micromol/l, respectively. The overall mean accuracies ranged from 96 to 106% and precision was in the range 4 to 11%. Cross validation indicated no significant difference between plasma concentrations obtained using the 96-well method and the previous method using a traditional SPE method with a 50 mg C18 cartridge. About a threefold increase in sample throughput and a twofold decrease of plasma volume required for the assays, were the main advantages obtained from the previous method. The method was applied for the determination of 3000 plasma samples from clinical studies.

  2. Radioimmunoassay of sodium cromoglycate in human plasma

    Energy Technology Data Exchange (ETDEWEB)

    Brown, K.; Gardner, J.J.; Lockley, W.J.S.; Preston, J.R.; Wilkinson, D.J. (Fisons plc, Loughborough (UK). Pharmaceutical Div.)

    1983-01-01

    A sensitive radioimmunoassay method for sodium cromoglycate in human plasma is described. The lowest quantifiable concentration of sodium cromoglycate is 0.93 nmol/l when 0.1 ml plasma samples are analysed. The range of the method is limited; both 0.01 and 0.1 ml volumes of plasma must be analysed to encompass the concentration range 0.93-139 nmol/l which may be encountered in plasma samples from patients and human volunteers. The method is specific for sodium cromoglycate as indicated by a low cross-reactivity of the anti-cromoglycate antiserum with a number of drugs.

  3. Dust remobilization in fusion plasmas

    CERN Document Server

    Tolias, P; De Angeli, M; De Temmerman, G; Ripamonti, D; Riva, G; Bykov, I; Shalpegin, A; Vignitchouk, L; Brochard, F; Bystrov, K; Bardin, S; Litnovsky, A

    2016-01-01

    The first combined experimental and theoretical studies of dust remobilization by plasma forces are reported. The main theoretical aspects of remobilization are analyzed. In particular, the dominant role of adhesive forces is highlighted and generic remobilization conditions - detachment, sliding, rolling - are formulated. A novel experimental technique is proposed, based on controlled adhesion of dust grains on tungsten samples combined with detailed mapping of the dust deposition profile prior and post plasma exposure. Proof-of-principle experiments in the TEXTOR tokamak and the EXTRAP-T2R reversed-field pinch are presented. The versatile environment of the linear device Pilot-PSI allowed for experiments with different magnetic field topologies and varying plasma conditions that were complemented with camera observations.

  4. [Plasma aminogram in critical patients].

    Science.gov (United States)

    Martínez, M J; Giráldez, J

    1993-02-01

    This study of the plasma aminogram was done on 35 patients with a moderate to high level of stress and/or sepsis. For the criteria of illness, the SAPS (Simplified Acute Physiological Score) was used on their admission to the intensive Care Unit, and the diagnosis of sepsis was established according to the criteria of Jacobs and Boone. The stress level was calculated according to Bistrian. The plasma aminogram was determined with High Resolution Liquid Chromatography. The plasma samples were taken while nutrient units containing what is considered a standard solution of amino acids were infused. The eight essential amino acids (EAA) and 10 non-essential were quantified. The ratio of ramified to aromatic amino acids (RAA/AAA) was calculated by Fisher's criteria. An increase in AAA (phenylalanine, p arginine, p metabolic stress and/or sepsis.

  5. Plasma Simulation Program

    Energy Technology Data Exchange (ETDEWEB)

    Greenwald, Martin

    2011-10-04

    Many others in the fusion energy and advanced scientific computing communities participated in the development of this plan. The core planning team is grateful for their important contributions. This summary is meant as a quick overview the Fusion Simulation Program's (FSP's) purpose and intentions. There are several additional documents referenced within this one and all are supplemental or flow down from this Program Plan. The overall science goal of the DOE Office of Fusion Energy Sciences (FES) Fusion Simulation Program (FSP) is to develop predictive simulation capability for magnetically confined fusion plasmas at an unprecedented level of integration and fidelity. This will directly support and enable effective U.S. participation in International Thermonuclear Experimental Reactor (ITER) research and the overall mission of delivering practical fusion energy. The FSP will address a rich set of scientific issues together with experimental programs, producing validated integrated physics results. This is very well aligned with the mission of the ITER Organization to coordinate with its members the integrated modeling and control of fusion plasmas, including benchmarking and validation activities. [1]. Initial FSP research will focus on two critical Integrated Science Application (ISA) areas: ISA1, the plasma edge; and ISA2, whole device modeling (WDM) including disruption avoidance. The first of these problems involves the narrow plasma boundary layer and its complex interactions with the plasma core and the surrounding material wall. The second requires development of a computationally tractable, but comprehensive model that describes all equilibrium and dynamic processes at a sufficient level of detail to provide useful prediction of the temporal evolution of fusion plasma experiments. The initial driver for the whole device model will be prediction and avoidance of discharge-terminating disruptions, especially at high performance, which are a

  6. The 2012 Plasma Roadmap

    Science.gov (United States)

    Samukawa, Seiji; Hori, Masaru; Rauf, Shahid; Tachibana, Kunihide; Bruggeman, Peter; Kroesen, Gerrit; Whitehead, J. Christopher; Murphy, Anthony B.; Gutsol, Alexander F.; Starikovskaia, Svetlana; Kortshagen, Uwe; Boeuf, Jean-Pierre; Sommerer, Timothy J.; Kushner, Mark J.; Czarnetzki, Uwe; Mason, Nigel

    2012-06-01

    Low-temperature plasma physics and technology are diverse and interdisciplinary fields. The plasma parameters can span many orders of magnitude and applications are found in quite different areas of daily life and industrial production. As a consequence, the trends in research, science and technology are difficult to follow and it is not easy to identify the major challenges of the field and their many sub-fields. Even for experts the road to the future is sometimes lost in the mist. Journal of Physics D: Applied Physics is addressing this need for clarity and thus providing guidance to the field by this special Review article, The 2012 Plasma Roadmap. Although roadmaps are common in the microelectronic industry and other fields of research and development, constructing a roadmap for the field of low-temperature plasmas is perhaps a unique undertaking. Realizing the difficulty of this task for any individual, the plasma section of the Journal of Physics D Board decided to meet the challenge of developing a roadmap through an unusual and novel concept. The roadmap was divided into 16 formalized short subsections each addressing a particular key topic. For each topic a renowned expert in the sub-field was invited to express his/her individual visions on the status, current and future challenges, and to identify advances in science and technology required to meet these challenges. Together these contributions form a detailed snapshot of the current state of the art which clearly shows the lifelines of the field and the challenges ahead. Novel technologies, fresh ideas and concepts, and new applications discussed by our authors demonstrate that the road to the future is wide and far reaching. We hope that this special plasma science and technology roadmap will provide guidance for colleagues, funding agencies and government institutions. If successful in doing so, the roadmap will be periodically updated to continue to help in guiding the field.

  7. Solar flares. [plasma physics

    Science.gov (United States)

    Rust, D. M.

    1979-01-01

    The present paper deals with explosions in a magnetized solar plasma, known as flares, whose effects are seen throughout the electromagnetic spectrum, from gamma-rays through the visible and to the radio band. The diverse phenomena associated with flares are discussed, along with the physical mechanisms that have been advanced to explain them. The impact of solar flare research on the development of plasma physics and magnetohydrodynamics is noted. The rapid development of solar flare research during the past 20 years, owing to the availability of high-resolution images, detailed magnetic field measurements, and improved spectral data, is illustrated.

  8. Kinetics of complex plasmas

    CERN Document Server

    Sodha, Mahendra Singh

    2014-01-01

    The presentation in the book is based on charge balance on the dust particles, number and energy balance of the constituents and atom-ion-electron interaction in the gaseous plasma. Size distribution of dust particles, statistical mechanics, Quantum effects in electron emission from and accretion on dust particles and nonlinear interaction of complex plasmas with electric and electromagnetic fields have been discussed in the book. The book introduces the reader to basic concepts and typical applications. The book should be of use to researchers, engineers and graduate students.

  9. Plasma Cell Disorders.

    Science.gov (United States)

    Castillo, Jorge J

    2016-12-01

    Plasma cell disorders are benign, premalignant, and malignant conditions characterized by the presence of a monoclonal paraprotein detected in serum or urine. These conditions are biologically, pathologically, and clinically heterogeneous. There have been major advances in the understanding of the biology of these diseases, which are promoting the development of therapies with novel mechanisms of action. Novel agents such as proteasome inhibitors, immunomodulatory drugs, and monoclonal antibodies have gained approval in the United States and Europe for the treatment of plasma cell disorders. Such therapies are translating into higher rates of response and survival and better toxicity profiles. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Plasma YKL-40

    DEFF Research Database (Denmark)

    Jensen, Peter; Wiell, C; Milting, K

    2013-01-01

    Background  Plasma YKL-40 is an inflammatory biomarker. No useful biomarker exists in patients with psoriasis or psoriatic arthritis. Objective  To measure YKL-40 and high-sensitivity C-reactive protein (hs-CRP) in patients with psoriasis or psoriatic arthritis before and during treatment. Methods......-CRP at inclusion and during 48 weeks of adalimumab treatment. The patients with psoriatic arthritis were divided into responders and non-responders. Results  In patients with psoriasis, the baseline median PASI score was 10.8 and baseline YKL-40 was 45 μg/L. Seventeen per cent had elevated plasma YKL-40 compared...

  11. Plasma polarization spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, Takashi; Iwamae, Atsushi (eds.) [Kyoto Univ. (Japan). Dept. of Mechanical Engineering and Science

    2008-07-01

    Plasma Polarization Spectroscopy (PPS) is now becoming a standard diagnostic technique for working with laboratory plasmas. This new area needs a comprehensive framework, both experimental and theoretical. This book reviews the historical development of PPS, develops a general theoretical formulation to deal with this phenomenon, along with an overview of relevant cross sections, and reports on laboratory experiments so far performed. It also includes various facets that are interesting from this standpoint, e.g. X-ray lasers and effects of microwave irradiation. It also offers a timely discussion of instrumentation that is quite important in a practical PPS experiment. (orig.)

  12. Plasma Assisted Combustion

    Science.gov (United States)

    2007-02-28

    pressure hydrogen is given in Fig. 2.14. The regions typical for “common” glow discharges (negative glow, Faraday dark space, and positive column) are...Hollenstein Ch. Plasma Phys. Control. Fusion, 42 (2000) 93. [107] M.A. Heald and C.B. Wahrton, Plasma diagnostics with microwaves, John Wi- ley &Sons, New York...Nitrous Oxide J. Chem. Soc. Faraday Trans. 69 352 [194] Albers E A, Hoyermann K, Schacke H, Schmatjko K J, Wagner H Gg, Wolfrum J 1975 Absolute Rate

  13. High plasma corticosterone levels persist during frequent automatic blood sampling in rats

    DEFF Research Database (Denmark)

    Abelson, Klas S P; Adem, Bashir; Royo, Felix

    2005-01-01

    Corticosterone levels in blood may be used as a marker of stress in rodents, provided that the blood sampling procedure itself is non-stressful. Automated blood sampling equipment (Accusampler) allows blood sampling without any interference with the animal and might be useful as a tool for an on...... the importance of considering the frequency of blood withdrawal during automated blood sampling. This parameter may have an impact on the experimental results when using blood corticosterone levels as a stress marker, but also during any in vivo study where blood is collected, since high corticosterone levels...... may affect the normal physiology of the animals....

  14. Determination of noble metals in biological samples by electrothermal vaporization inductively coupled plasma mass spectrometry, following cloud point extraction

    Science.gov (United States)

    Andreia Mesquita da Silva, Márcia; Lúcia Azzolin Frescura, Vera; José Curtius, Adilson

    2001-10-01

    A simple separation procedure for noble metals based on cloud point extraction is proposed. The analyte ions in aqueous acidic solution, obtained by the acid digestion of the samples, were complexed with O, O-diethyl-dithiophosphate and Triton X-114 was added as a non-ionic surfactant. By increasing the temperature up to the cloud point, a phase separation occurs, resulting in an aqueous phase and a surfactant-rich phase containing most of the analytes that were complexed. The metals in the surfactant-rich phase were determined by electrothermal vaporization inductively coupled plasma mass spectrometry. The extraction conditions as well as the instrumental parameters were optimized. Enrichment factors ranging from 7 (Rh) to 60 (Pt) and limits of detection from 0.6 (Pt) to 3.0 ng l -1 (Rh) were obtained in the digested samples. The extraction was not efficient for Ir. Among the reference materials analyzed in this work, only one (SRM 2670, urine) presented recommended values for Au and Pt. Due to the non-availability of adequate CRMs, accuracy was assessed by spiking known analyte amounts to the acid digests. Recoveries close to 100% were observed for all the studied elements but Ru. Poor agreement between found and recommended values was observed for non-digested urine sample, probably due to the carrier effect of co-extracted residual matrix components. However, good agreement was reached after urine acid mineralization.

  15. Optical properties of cluster plasma

    Energy Technology Data Exchange (ETDEWEB)

    Kishimoto, Yasuaki; Tajima, Toshiki [Japan Atomic Energy Research Inst., Neyagawa, Osaka (Japan). Kansai Research Establishment; Downer, M.C.

    1998-03-01

    It is shown that unlike a gas plasma or an electron plasma in a metal, an ionized clustered material (`cluster plasma`) permits propagation below the plasma cut-off of electromagnetic (EM) waves whose phase velocity is close to but below the speed of light. This results from the excitation of a plasma oscillation mode (and/or polarization mode) through the cluster surface which does not exist in usual gaseous plasma. The existence of this new optical mode, cluster mode, is confirmed via numerical simulation. (author)

  16. Plasma scattering of electromagnetic radiation

    CERN Document Server

    Sheffield, John

    1975-01-01

    Plasma Scattering of Electromagnetic Radiation covers the theory and experimental application of plasma scattering. The book discusses the basic properties of a plasma and of the interaction of radiation with a plasma; the relationship between the scattered power spectrum and the fluctuations in plasma density; and the incoherent scattering of low-temperature plasma. The text also describes the constraints and problems that arise in the application of scattering as a diagnostic technique; the characteristic performance of various dispersion elements, image dissectors, and detectors; and the ge

  17. Evaluation of seasonal and daily changes of plasma thyroxine and cortisol levels in wild masu salmon Oncorhynchus masou, sampled by a Japanese fishing method.

    Science.gov (United States)

    Munakata, A; Miura, G; Matsuda, H

    2014-10-01

    A new fish sampling method was developed using a Japanese bait fishing rod (8-9 m carbon rod and a nylon line with a small fine wire single hook), which is considered to catch wild salmonid juveniles with low sampling stress. Using this method, seasonal and daily changes of plasma thyroxine (T4 ) and cortisol levels were examined in wild parr, pre-smolts and smolts of masu salmon Oncorhynchus masou in contiguous locations in a coastal river (Kesen River; 44 km) in northern Honshu Island, Japan, overlapping the period of smoltification and seaward migration from August to March. Plasma T4 and cortisol were low in 0+ and 1+ year parr caught in August and September. In March, some yearling (1+ year) fish, which were judged as pre-smolts, and smolts appeared mainly in mid and lower reaches, while parr (0+ and 1+ year parr) continued to appear in the upper and mid reaches. In March, 1+ year pre-smolts and smolts showed high plasma T4 levels while the levels of 1+ year parr were low. During March 2008-2010, plasma T4 levels of 1+ year pre-smolts and smolts had high levels from early to mid-March, whereas plasma cortisol levels of 1+ year smolts were low in early March and increased towards mid-March. Based on these data, plasma cortisol increases probably occur following the increases of plasma T4 levels to lead the 1+ year O. masou to the completion of smoltification and initiation of seaward migration. © 2014 The Fisheries Society of the British Isles.

  18. Some plasma aspects and plasma diagnostics of ion sources.

    Science.gov (United States)

    Wiesemann, Klaus

    2008-02-01

    We consider plasma properties in the most advanced type of plasma ion sources, electron cyclotron resonance ion sources for highly charged ions. Depending on the operation conditions the plasma in these sources may be highly ionized, which completely changes its transport properties. The most striking difference to weakly ionized plasma is that diffusion will become intrinsically ambipolar. We further discuss means of plasma diagnostics. As noninvasive diagnostic methods we will discuss analysis of the ion beam, optical spectroscopy, and measurement of the x-ray bremsstrahlung continuum. From beam analysis and optical spectroscopy one may deduce ion densities, and electron densities and distribution functions as a mean over the line of sight along the axis (optical spectroscopy) or at the plasma edge (ion beam). From x-ray spectra one obtains information about the population of highly energetic electrons and the energy transfer from the driving electromagnetic waves to the plasma -- basic data for plasma modeling.

  19. The field of plasmas. L'univers des plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Bradu, P. (Direction des Recherches, Etudes et Techniques d' Armement (DRET), (France))

    1999-01-01

    Plasma is the fourth state of matter and it is the most spread at the scale of universe. Plasma is involved in natural phenomena such as Saint-Elmo's fires, aurora borealis or lightning discharges. Thanks to its particular properties plasma is used in many fields of technology. We find plasmas in light bulbs, television screens and in diverse industrial processes such as laser isotope separation, sterilization, surface coating, or waste treatment where a plasma torch is used to reduce waste into its elementary components trapped in the molten bulk. Spatial propulsion could soon benefit by the application of magnetohydrodynamics effects to plasmas. Thermonuclear reactors where fusion reactions take place in a very hot plasma could be the source of energy for the next century. This book deals with all the aspects of plasma in the technology of today. (A.C.) 21 refs.

  20. The field of plasmas; L`univers des plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Bradu, P. [Direction des Recherches, Etudes et Techniques d`Armement (DRET), (France)

    1999-12-01

    Plasma is the fourth state of matter and it is the most spread at the scale of universe. Plasma is involved in natural phenomena such as Saint-Elmo`s fires, aurora borealis or lightning discharges. Thanks to its particular properties plasma is used in many fields of technology. We find plasmas in light bulbs, television screens and in diverse industrial processes such as laser isotope separation, sterilization, surface coating, or waste treatment where a plasma torch is used to reduce waste into its elementary components trapped in the molten bulk. Spatial propulsion could soon benefit by the application of magnetohydrodynamics effects to plasmas. Thermonuclear reactors where fusion reactions take place in a very hot plasma could be the source of energy for the next century. This book deals with all the aspects of plasma in the technology of today. (A.C.) 21 refs.

  1. Microwave Probing of Air-Plasma and Plasma Metamaterials

    Science.gov (United States)

    Schneider, Katherine; Rock, Ben; Helle, Mike

    2016-10-01

    Plasma metamaterials are of recent interest due to their unique ability to be engineered with specific electromagnetic responses. One potential metamaterial architecture is based on a `forest' of plasma rods that can be produced using intense laser plasma filaments. In our work, we use a continuous microwave source at 26.5 GHz to measure a single air plasma filament characteristics generated from a 5 mJ laser pulse within a cylindrical hole in a Ka-band waveguide. Preliminary results show the air plasma produces a strong shock and acts to reflect microwave radiation. A computational comparison using 3D EM modeling is performed to examine the reflection and transmission properties of a single plasma rod, and further, to investigate an array of plasma rods as a potential plasma based metamaterial.

  2. Partially ionized plasmas including the third symposium on uranium plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Krishnan, M. [ed.

    1976-09-01

    Separate abstracts are included for 28 papers on electrically generated plasmas, fission generated plasmas, nuclear pumped lasers, gaseous fuel reactor research, and applications. Five papers have been previously abstracted and included in ERA.

  3. Plasma detachment with molecular processes in divertor plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, N.; Ezumi, N.; Nishijima, D.; Takamura, S. [Dept. of Energy Engineering and Science, Graduate School of Engineering, Nagoya Univ., Nagoya, Aichi (Japan); Krasheninnikov, S.I.; Pigarov, A.Yu. [MIT Plasma Science and Fusion Center, Cambridge, MA (United States)

    2000-01-01

    Molecular processes in detached recombining plasmas are briefly reviewed. Several reactions with vibrationally excited hydrogen molecule related to recombination processes are described. Experimental evidence of molecular activated recombination observed in a linear divertor plasma simulator is also shown. (author)

  4. Plasma flow in peripheral region of detached plasma in linear plasma device

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Y., E-mail: hayashi-yuki13@ees.nagoya-u.ac.jp; Ohno, N. [Graduate School of Engineering, Nagoya University, Nagoya, Aichi 464-8603 (Japan); Kajita, S. [EcoTopia Science Institute, Nagoya University, Nagoya, Aichi 464-8603 (Japan); Tanaka, H. [National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan)

    2016-01-15

    A plasma flow structure is investigated using a Mach probe under detached plasma condition in a linear plasma device NAGDIS-II. A reverse flow along the magnetic field is observed in a steady-state at far-peripheral region of the plasma column in the upstream side from the recombination front. These experimental results indicate that plasma near the recombination front should strongly diffuse across the magnetic field, and it should be transported along the magnetic field in the reverse flow direction. Furthermore, bursty plasma density fluctuations associated with intermittent convective plasma transport are observed in the far-peripheral region of the plasma column in both upstream and downstream sides from the recombination front. Such a nondiffusive transport can contribute to the intermittent reverse plasma flow, and the experimental results indicate that intermittent transports are frequently produced near the recombination front.

  5. Pre-storage centrifugation conditions have significant impact on measured microRNA levels in biobanked EDTA plasma samples

    DEFF Research Database (Denmark)

    Binderup, Helle Glud; Houlind, Kim; Madsen, Jonna Skov;

    2016-01-01

    was significantly higher in the re-centrifuged biobanked plasma compared to PPP, even when the platelet count was reduced to 0-1×109/L. Conclusion: We found, that pre-storage centrifugation conditions have a significant impact on the measured EDTA plasma level of miRNAs known to be present in platelets. Even......Background: In the past few years, an increasing number of studies have reported the potential use of microRNAs (miRNA) as circulating biomarkers for diagnosis or prognosis of a wide variety of diseases. There is, however, a lack of reproducibility between studies. Due to the high miRNA content...

  6. Laser-plasma-based linear collider using hollow plasma channels

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, C.B., E-mail: CBSchroeder@lbl.gov; Benedetti, C.; Esarey, E.; Leemans, W.P.

    2016-09-01

    A linear electron–positron collider based on laser-plasma accelerators using hollow plasma channels is considered. Laser propagation and energy depletion in the hollow channel is discussed, as well as the overall efficiency of the laser-plasma accelerator. Example parameters are presented for a 1-TeV and 3-TeV center-of-mass collider based on laser-plasma accelerators.

  7. Production of aerosols by optical catapulting: Imaging, performance parameters and laser-induced plasma sampling rate

    Science.gov (United States)

    Abdelhamid, M.; Fortes, F. J.; Fernández-Bravo, A.; Harith, M. A.; Laserna, J. J.

    2013-11-01

    Optical catapulting (OC) is a sampling and manipulation method that has been extensively studied in applications ranging from single cells in heterogeneous tissue samples to analysis of explosive residues in human fingerprints. Specifically, analysis of the catapulted material by means of laser-induced breakdown spectroscopy (LIBS) offers a promising approach for the inspection of solid particulate matter. In this work, we focus our attention in the experimental parameters to be optimized for a proper aerosol generation while increasing the particle density in the focal region sampled by LIBS. For this purpose we use shadowgraphy visualization as a diagnostic tool. Shadowgraphic images were acquired for studying the evolution and dynamics of solid aerosols produced by OC. Aluminum silicate particles (0.2-8 μm) were ejected from the substrate using a Q-switched Nd:YAG laser at 1064 nm, while time-resolved images recorded the propagation of the generated aerosol. For LIBS analysis and shadowgraphy visualization, a Q-switched Nd:YAG laser at 1064 nm and 532 nm was employed, respectively. Several parameters such as the time delay between pulses and the effect of laser fluence on the aerosol production have been also investigated. After optimization, the particle density in the sampling focal volume increases while improving the aerosol sampling rate till ca. 90%.

  8. An efficient sample preparation method for high-throughput analysis of 15(S)-8-iso-PGF2α in plasma and urine by enzyme immunoassay.

    Science.gov (United States)

    Bielecki, A; Saravanabhavan, G; Blais, E; Vincent, R; Kumarathasan, P

    2012-01-01

    Although several methods have been reported on the analysis of the oxidative stress marker 15(S)-8-iso-prostaglandin-F2alpha (8-iso-PGF2α) in biological fluids, they either involve extensive sample preparation and costly technology or require high sample volume. This study presents a sample preparation method that utilizes low sample volume for 8-iso-PGF2α analysis in plasma and urine by an enzyme immunoassay (EIA). In brief, 8-iso-PGF2α in deproteinized plasma or native urine sample is complexed with an antibody and then captured by molecular weight cut-off filtration. This method was compared with two other sample preparation methods that are typically used in the analysis of 8-iso-PGF2α by EIA: Cayman's affinity column purification method and solid-phase extraction on C-18. The immunoaffinity purification method described here was superior to the other two sample preparation methods and yielded recovery values of 99.8 and 54.1% for 8-iso-PGF2α in plasma and urine, respectively. Analytical precision (relative standard deviation) was ±5% for plasma and ±15% for urine. The analysis of healthy human plasma and urine resulted in basal 8-iso-PGF2α levels of 31.8 ± 5.5 pg/mL and 2.9 ± 2.0 ng/mg creatinine, respectively. The robustness and analytical performance of this method makes it a promising tool for high-throughput screening of biological samples for 8-iso-PGF2α.

  9. Computations in Plasma Physics.

    Science.gov (United States)

    Cohen, Bruce I.; Killeen, John

    1983-01-01

    Discusses contributions of computers to research in magnetic and inertial-confinement fusion, charged-particle-beam propogation, and space sciences. Considers use in design/control of laboratory and spacecraft experiments and in data acquisition; and reviews major plasma computational methods and some of the important physics problems they…

  10. Merging of plasma currents

    NARCIS (Netherlands)

    Bergmans, J.; Schep, T. J.

    2001-01-01

    The merging process of current filaments in a strongly magnetized plasma is described. The evolution is calculated using a contour dynamics method, which accurately tracks piecewise constant distributions of the conserved quantities. In the interaction of two screened currents, both develop dipolar

  11. Microscopic plasma Hamiltonian

    Science.gov (United States)

    Peng, Y.-K. M.

    1974-01-01

    A Hamiltonian for the microscopic plasma model is derived from the Low Lagrangian after the dual roles of the generalized variables are taken into account. The resulting Hamilton equations are shown to agree with the Euler-Lagrange equations of the Low Lagrangian.

  12. Flare Plasma Iron Abundance

    Science.gov (United States)

    Dennis, Brian R.; Dan, Chau; Jain, Rajmal; Schwartz, Richard A.; Tolbert, Anne K.

    2008-01-01

    The equivalent width of the iron-line complex at 6.7 keV seen in flare X-ray spectra suggests that the iron abundance of the hottest plasma at temperatures >approx.10 MK may sometimes be significantly lower than the nominal coronal abundance of four times the photospheric value that is commonly assumed. This conclusion is based on X-ray spectral observations of several flares seen in common with the Ramaty High Energy Solar Spectroscopic Imager (RHESSI) and the Solar X-ray Spectrometer (SOXS) on the second Indian geostationary satellite, GSAT-2. The implications of this will be discussed as it relates to the origin of the hot flare plasma - either plasma already in the corona that is directly heated during the flare energy release process or chromospheric plasma that is heated by flare-accelerated particles and driven up into the corona. Other possible explanations of lower-than-expected equivalent widths of the iron-line complex will also be discussed.

  13. Quark gluon plasma

    Indian Academy of Sciences (India)

    C P Singh

    2000-04-01

    Recent trends in the research of quark gluon plasma (QGP) are surveyed and the current experimental and theoretical status regarding the properties and signals of QGP is reported. We hope that the experiments commencing at relativistic heavy-ion collider (RHIC) in 2000 will provide a glimpse of the QGP formation.

  14. Pulsed Plasma Electron Sources

    Science.gov (United States)

    Krasik, Yakov

    2008-11-01

    Pulsed (˜10-7 s) electron beams with high current density (>10^2 A/cm^2) are generated in diodes with electric field of E > 10^6 V/cm. The source of electrons in these diodes is explosive emission plasma, which limits pulse duration; in the case E Hadas and Ya. E. Krasik, Europhysics Lett. 82, 55001 (2008).

  15. Plasma Theory and Simulation.

    Science.gov (United States)

    1982-12-31

    expan- sion of a warm plasma; launching and propagation and decay of very large amplitude waves (8GK, solitons, etc.); thermal barriers (really...25.373.1981. ION-10N TWO-STREAM IN THERMAL BARRIERS : Vincent-lhonal,U.C.Berkeley. We present stu- dies or the eleclroTatic ion-ion two-stream instability as

  16. Plasma Theory and Simulation.

    Science.gov (United States)

    1980-09-30

    William Nevins L439 LLL (422-7032) Lecturers , UCB; Physicists -LLL Dr. William Fawley Guest, UCB; Physicist LLL L321 LLL (422-9272) Yu-Jiuan Chen, Douglas... MHD - Particle Codes." Three abstracts of papers prepared for the APS Division of Plasma Physics Meeting, November 10-14, 1980, at San Diego, follow

  17. Vacuum plasma spray coating

    Science.gov (United States)

    Holmes, Richard R.; Mckechnie, Timothy N.

    1989-01-01

    Currently, protective plasma spray coatings are applied to space shuttle main engine turbine blades of high-performance nickel alloys by an air plasma spray process. Originally, a ceramic coating of yttria-stabilized zirconia (ZrO2.12Y2O3) was applied for thermal protection, but was removed because of severe spalling. In vacuum plasma spray coating, plasma coatings of nickel-chromium-aluminum-yttrium (NiCrAlY) are applied in a reduced atmosphere of argon/helium. These enhanced coatings showed no spalling after 40 MSFC burner rig thermal shock cycles between 927 C (1700 F) and -253 C (-423 F), while current coatings spalled during 5 to 25 test cycles. Subsequently, a process was developed for applying a durable thermal barrier coating of ZrO2.8Y2O3 to the turbine blades of first-stage high-pressure fuel turbopumps utilizing the enhanced NiCrAlY bond-coating process. NiCrAlY bond coating is applied first, with ZrO2.8Y2O3 added sequentially in increasing amounts until a thermal barrier coating is obtained. The enchanced thermal barrier coating has successfully passed 40 burner rig thermal shock cycles.

  18. Fundamentals of plasma physics

    CERN Document Server

    Bittencourt, J A

    1986-01-01

    A general introduction designed to present a comprehensive, logical and unified treatment of the fundamentals of plasma physics based on statistical kinetic theory. Its clarity and completeness make it suitable for self-learning and self-paced courses. Problems are included.

  19. Magnetized Plasma Experiments Using Thermionic- Thermoelectronic Plasma Emitter

    Science.gov (United States)

    Kawamori, Eiichirou; Cheng, C. Z.; Fujikawa, Nobuko; Lee, Jyun-Yi; Peng, Albert

    2008-11-01

    We are developing a magnetic mirror device, which is the first magnetized plasma device in Taiwan, to explore basic plasma sciences relevant to fusion, space and astrophysical plasmas. Our research subjects include electromagnetically induced transparency (EIT), Alfven wave physics, and plasma turbulence. A large diameter (> 200 mm) plasma emitter1, which utilizes thermionic- thermoelectronic emission from a mixture of LaB6 (Lanthanum-hexaboride) and beta-eucryptite (lithium type aluminosylicate) powders, is employed as a plasma source because of its production ability of fully ionized plasma and controllability of plasma emission rate. The plasma emitter has been installed recently and investigation of its characteristics will be started. The employment of beta-eucryptite in plasma emitter is the first experimental test because such investigation of beta-eucryptite has previously been used only for Li+-ion source2. Our plan for magnetized plasma experiments and results of the plasma emitter investigation will be presented. 1. K. Saeki, S. Iizuka, N. Sato, and Y. Hatta, Appl. Phys. Lett., 37, 1980, pp. 37-38. 2. M. Ueda, R. R. Silva, R. M. Oliveira, H. Iguchi, J. Fujita and K. Kadota, J. Phys. D: Appl. Phys. 30 1997, pp. 2711--2716.

  20. The 2017 Plasma Roadmap: Low temperature plasma science and technology

    Science.gov (United States)

    Journal of Physics D: Applied Physics published the first Plasma Roadmap in 2012 consisting of the individual perspectives of 16 leading experts in the various sub-fields of low temperature plasma science and technology. The 2017 Plasma Roadmap is the first update of a planned series of periodic upd...

  1. Modelling the Plasma Jet in Multi-Arc Plasma Spraying

    Science.gov (United States)

    Bobzin, K.; Öte, M.; Schein, J.; Zimmermann, S.; Möhwald, K.; Lummer, C.

    2016-08-01

    Particle in-flight characteristics in atmospheric plasma spraying process are determined by impulse and heat energy transferred between the plasma jet and injected powder particles. One of the important factors for the quality of the plasma-sprayed coatings is thus the distribution of plasma gas temperatures and velocities in plasma jet. Plasma jets generated by conventional single-arc plasma spraying systems and their interaction with powder particles were subject matter of intensive research. However, this does not apply to plasma jets generated by means of multi-arc plasma spraying systems yet. In this study, a numerical model has been developed which is designated to dealing with the flow characteristics of the plasma jet generated by means of a three-cathode spraying system. The upstream flow conditions, which were calculated using a priori conducted plasma generator simulations, have been coupled to the plasma jet simulations. The significances of the relevant numerical assumptions and aspects of the models are analyzed. The focus is placed on to the turbulence and diffusion/demixing modelling. A critical evaluation of the prediction power of the models is conducted by comparing the numerical results to the experimental results determined by means of emission spectroscopic computed tomography. It is evident that the numerical models exhibit a good accuracy for their intended use.

  2. Multielement determination of heavy metals in water samples by continuous powder introduction microwave-induced plasma atomic emission spectrometry after preconcentration on activated carbon

    Science.gov (United States)

    Jankowski, Krzysztof; Yao, Jun; Kasiura, Krzysztof; Jackowska, Adrianna; Sieradzka, Anna

    2005-03-01

    A novel continuous powder introduction microwave-induced plasma atomic emission spectrometry method (CPI-MIP-AES) has been developed for trace determination of metals in ground and tap water samples after preconcentration on activated carbon. The experimental setup consisted of integrated rectangular cavity TE 101 and vertically positioned plasma torch. The technical arrangement of the sample introduction system has been designed based on the fluidized bed concept. The satisfactory signal stability required for sequential analysis was attained owing to the vertical plasma configuration, as well as the plasma gas flow rate compatibility with sample introduction flow rate. The elements of interest (Cd, Cu, Cr, Fe, Mn, Pb, Zn) were preconcentrated in a batch procedure at pH 8-8.5 after addition of activated carbon and then, after filtering and drying of the activated carbon suspension, introduced to the MIP by the CPI system. An enrichment factor of about 1000-fold for a sample volume of 1 l was obtained. The detection limit values for the proposed method were 17-250 ng l -1. The proposed method was validated by analyzing the certified reference materials: SRW "Warta" Synthetic River Water and BCR CRM 399 major elements in freshwater. The method was successfully applied to the determination of the heavy metals in tap water samples.

  3. Multielement determination of heavy metals in water samples by continuous powder introduction microwave-induced plasma atomic emission spectrometry after preconcentration on activated carbon

    Energy Technology Data Exchange (ETDEWEB)

    Jankowski, Krzysztof [Warsaw University of Technology, Faculty of Chemistry, Department of Analytical Chemistry, 00-664 Warsaw, ul. Noakowskiego 3 (Poland)]. E-mail: kj@ch.pw.edu.pl; Yao Jun [College of Chemistry and Chemical Engineering, Jishou University, 120 Renmin South Road, Jishou 416000 (China); Kasiura, Krzysztof [Warsaw University of Technology, Faculty of Chemistry, Department of Analytical Chemistry, 00-664 Warsaw, ul. Noakowskiego 3 (Poland); Jackowska, Adrianna [Warsaw University of Technology, Faculty of Chemistry, Department of Analytical Chemistry, 00-664 Warsaw, ul. Noakowskiego 3 (Poland); Sieradzka, Anna [Warsaw University of Technology, Faculty of Chemistry, Department of Analytical Chemistry, 00-664 Warsaw, ul. Noakowskiego 3 (Poland)

    2005-03-31

    A novel continuous powder introduction microwave-induced plasma atomic emission spectrometry method (CPI-MIP-AES) has been developed for trace determination of metals in ground and tap water samples after preconcentration on activated carbon. The experimental setup consisted of integrated rectangular cavity TE{sub 101} and vertically positioned plasma torch. The technical arrangement of the sample introduction system has been designed based on the fluidized bed concept. The satisfactory signal stability required for sequential analysis was attained owing to the vertical plasma configuration, as well as the plasma gas flow rate compatibility with sample introduction flow rate. The elements of interest (Cd, Cu, Cr, Fe, Mn, Pb, Zn) were preconcentrated in a batch procedure at pH 8-8.5 after addition of activated carbon and then, after filtering and drying of the activated carbon suspension, introduced to the MIP by the CPI system. An enrichment factor of about 1000-fold for a sample volume of 1 l was obtained. The detection limit values for the proposed method were 17-250 ng l{sup -1}. The proposed method was validated by analyzing the certified reference materials: SRW 'Warta' Synthetic River Water and BCR CRM 399 major elements in freshwater. The method was successfully applied to the determination of the heavy metals in tap water samples.

  4. DETERMINATION OF 237NP AND PU ISOTOPES IN LARGE SOIL SAMPLES BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, S.

    2010-07-26

    A new method for the determination of {sup 237}Np and Pu isotopes in large soil samples has been developed that provides enhanced uranium removal to facilitate assay by inductively coupled plasma mass spectrometry (ICP-MS). This method allows rapid preconcentration and separation of plutonium and neptunium in large soil samples for the measurement of {sup 237}Np and Pu isotopes by ICP-MS. {sup 238}U can interfere with {sup 239}Pu measurement by ICP-MS as {sup 238}UH{sup +} mass overlap and {sup 237}Np via {sup 238}U peak tailing. The method provides enhanced removal of uranium by separating Pu and Np initially on TEVA Resin, then transferring Pu to DGA resin for additional purification. The decontamination factor for removal of uranium from plutonium for this method is greater than 1 x 10{sup 6}. Alpha spectrometry can also be applied so that the shorter-lived {sup 238}Pu isotope can be measured successfully. {sup 239}Pu, {sup 242}Pu and {sup 237}Np were measured by ICP-MS, while {sup 236}Pu and {sup 238}Pu were measured by alpha spectrometry.

  5. Molecularly imprinted polymers based on SBA-15 for selective solid-phase extraction of baicalein from plasma samples.

    Science.gov (United States)

    He, Hongliang; Gu, Xiaoli; Shi, Liying; Hong, Junli; Zhang, Hongjuan; Gao, Yankun; Du, Shuhu; Chen, Lina

    2015-01-01

    Highly selective molecularly imprinted mesoporous silica polymer (SBA-15@MIP) for baicalein (BAI) extraction was synthesized using a surface molecular imprinting technique on the SBA-15 supporter. Computational simulation was used to predict the optimal functional monomer for the rational design of SBA-15@MIP. Meanwhile, high adsorption capacity was obtained when a suitable yield of molecularly imprinted polymers (MIPs) layer was grafted onto the surface of SBA-15. Characterization and performance tests of the obtained polymer revealed that SBA-15@MIP possessed a highly ordered mesoporous structure, reached saturated adsorption within 60 min, and exhibited higher sorption capacity to the target molecule BAI compared with non-imprinted mesoporous silica polymer (SBA-15@NIP) and SBA-15. Finally, SBA-15@MIP was successfully applied to solid-phase extraction (SPE) coupled with high-performance liquid chromatography and ultraviolet detection (HPLC-UV) for the determination of trace BAI in plasma samples. Mean recoveries of BAI through the molecularly imprinted solid-phase extraction (MISPE) sorbent, non-imprinted solid-phase extraction (NISPE) sorbent, and SBA-15 solid-phase extraction (SBA-15-SPE) sorbent were 94.4, 22.7, and 10.7 %, respectively, and the relative standard deviations were 2.9, 2.6, and 3.6 %, respectively. These results reveal that SBA-15@MIP as a SPE sorbent has good applicability to selectively separate and enrich trace BAI from complex samples.

  6. PFAS concentrations in plasma samples from Danish school children and their mothers

    DEFF Research Database (Denmark)

    Mørck, Thit Aarøe; Nielsen, Flemming; Nielsen, Jeanette Kolstrup Søgaard

    2015-01-01

    Perfluoroalkyl substances (PFASs) are accumulating in our environment and human exposure to these potentially harmful chemicals are of growing concern. In the present study, 116 children aged 6–11 and 143 mothers in two locations in Denmark donated blood samples as a supplement to their participa......Perfluoroalkyl substances (PFASs) are accumulating in our environment and human exposure to these potentially harmful chemicals are of growing concern. In the present study, 116 children aged 6–11 and 143 mothers in two locations in Denmark donated blood samples as a supplement......-PFOS and total-PFOS were significantly higher in children compared to their mothers. This may be due to higher exposure in children through for example dust and soil, and due to the fact that children are smaller in body size and blood volume and hence have a lower storage capacity. Furthermore, we found...

  7. Theory of gas discharge plasma

    CERN Document Server

    Smirnov, Boris M

    2015-01-01

    This book presents the theory of gas discharge plasmas in a didactical way. It explains the processes in gas discharge plasmas. A gas discharge plasma is an ionized gas which is supported by an external electric field. Therefore its parameters are determined by processes in it. The properties of a gas discharge plasma depend on its gas component, types of external fields, their geometry and regimes of gas discharge. Fundamentals of a gas discharge plasma include elementary, radiative and transport processes which are included in its kinetics influence. They are represented in this book together with the analysis of simple gas discharges. These general principles are applied to stationary gas discharge plasmas of helium and argon. The analysis of such plasmas under certain conditions is theoretically determined by numerical plasma parameters for given regimes and conditions.

  8. Modelling of Complex Plasmas

    Science.gov (United States)

    Akdim, Mohamed Reda

    2003-09-01

    Nowadays plasmas are used for various applications such as the fabrication of silicon solar cells, integrated circuits, coatings and dental cleaning. In the case of a processing plasma, e.g. for the fabrication of amorphous silicon solar cells, a mixture of silane and hydrogen gas is injected in a reactor. These gases are decomposed by making a plasma. A plasma with a low degree of ionization (typically 10_5) is usually made in a reactor containing two electrodes driven by a radio-frequency (RF) power source in the megahertz range. Under the right circumstances the radicals, neutrals and ions can react further to produce nanometer sized dust particles. The particles can stick to the surface and thereby contribute to a higher deposition rate. Another possibility is that the nanometer sized particles coagulate and form larger micron sized particles. These particles obtain a high negative charge, due to their large radius and are usually trapped in a radiofrequency plasma. The electric field present in the discharge sheaths causes the entrapment. Such plasmas are called dusty or complex plasmas. In this thesis numerical models are presented which describe dusty plasmas in reactive and nonreactive plasmas. We started first with the development of a simple one-dimensional silane fluid model where a dusty radio-frequency silane/hydrogen discharge is simulated. In the model, discharge quantities like the fluxes, densities and electric field are calculated self-consistently. A radius and an initial density profile for the spherical dust particles are given and the charge and the density of the dust are calculated with an iterative method. During the transport of the dust, its charge is kept constant in time. The dust influences the electric field distribution through its charge and the density of the plasma through recombination of positive ions and electrons at its surface. In the model this process gives an extra production of silane radicals, since the growth of dust is

  9. Lipid emulsion solution: A novel cause of hemolysis in serum and plasma blood samples.

    Science.gov (United States)

    Jaben, Elizabeth A; Koch, Christopher D; Karon, Brad S

    2011-02-01

    After several hemolyzed blood samples were received in the laboratory, we investigated lipid emulsion/TPN as a novel cause of hemolysis. Whole blood was spiked with lipid emulsion and TPN. Hemolysis was proportional to the amount of lipid emulsion present in whole blood, with less hemolysis occurring in blood gas syringes compared to vacutainer tubes. Collection of specimens in blood gas syringes may prevent hemolysis in patients on lipid emulsion. Copyright © 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  10. Mixed Wastes Vitrification by Transferred Plasma

    Institute of Scientific and Technical Information of China (English)

    J.TAPIA-FABELA; G.ZlSSIS; M.PACHECO-PACHECO; J.PACHECO-SOTELO; C.TORRES-REYES; R.VALDIVIA-BARRIENTOS; J.BENITEZ-READ; R.LOPEZ-CALLEJAS; F.RAMOS-FLORES; S.BOSHLE

    2007-01-01

    Thermal plasma technology provides a stable and long term treatment of mixed wastes through vitrification processes.In this work,a transferred plasma system was realized to vitrify mixed wastes,taking advantage of its high power density,enthalpy and chemical reactivity as well as its rapid quenching and high operation temperatures.To characterize the plasma discharge,a temperature diagnostic is realized by means of optical emission spectroscopy (OES).To typify the morphological structure of the wastes samples,scanning electron microscopy (SEM),and X-ray diffraction (XRD) techniques were applied before and after the plasma treatment.

  11. Reliability of a Cryoscopic Micro-Osmometer Using 15-µL Plasma Samples to Measure Hydration Status in Varied Environmental Conditions

    Science.gov (United States)

    Scanlan, Aaron T.; Richter-Stretton, Gina L.; Madueno, Maria C.; Borges, Nattai R.; Fenning, Andrew S.

    2017-01-01

    Measurement of plasma osmolality (P[subscript osm]) remains popular for assessing hydration status in exercise science. However, a controlled reliability assessment of micro-osmometry using small sample volumes to measure Posm remains to be performed. This study aimed to examine the reliability of a cryoscopic micro-osmometer requiring 15-µL…

  12. Reliability of a Cryoscopic Micro-Osmometer Using 15-µL Plasma Samples to Measure Hydration Status in Varied Environmental Conditions

    Science.gov (United States)

    Scanlan, Aaron T.; Richter-Stretton, Gina L.; Madueno, Maria C.; Borges, Nattai R.; Fenning, Andrew S.

    2017-01-01

    Measurement of plasma osmolality (P[subscript osm]) remains popular for assessing hydration status in exercise science. However, a controlled reliability assessment of micro-osmometry using small sample volumes to measure Posm remains to be performed. This study aimed to examine the reliability of a cryoscopic micro-osmometer requiring 15-µL…

  13. Pretreatment of plasma samples by a novel hollow fiber centrifugal ultrafiltration technique for the determination of plasma protein binding of three coumarins using acetone as protein binding releasing agent.

    Science.gov (United States)

    Li, Junmei; Shi, Qingwen; Jiang, Ye; Liu, Yan

    2015-09-15

    A novel and practical sample pretreatment method based on hollow fiber centrifugal ultrafiltration (HFCF-UF) was developed to determine plasma protein binding by using HPLC. The samples for analyzing unbound and total concentrations could be prepared in parallel simultaneously by the same device. It only required centrifugation for a short time and the filtrate could be injected directly for HPLC analysis without further treatment. Coumarins were selected as the model drugs. Acetone was chosen as the releasing agent to free the binding drug from the drug-protein complex for the total drug concentration determination. Non-specific bindings (NSBs) between the analytes and hollow fiber membrane materials were investigated. The type and volume of protein binding releaser were optimized. Additionally, centrifugal speed and centrifugal time were considered. Under the optimized conditions, the absolute recovery rates of the unbound and total concentrations were in the range of 97.5-100.9% for the three analytes. The limits of detection were in the range of 0.0135-0.0667μgmL(-1). In vitro plasma protein binding of the three coumarins was determined at three concentrations using the validated method and the relative standard deviations (RSDs) were less than 3.4%. Compared with traditional method, the HFCF-UF method is simple to run, no specialized equipment requirement and is a more accurate plasma pretreatment procedure with almost excellent drug-protein binding equilibrium. Therefore, this method can be applied to determine the plasma protein binding in clinical practice. It also provides a reliable alternative for accurate monitoring of unbound or total drug concentration in therapeutic drug monitoring (TDM).

  14. Extraction of HCV-RNA from Plasma Samples: Development towards Semiautomation

    Directory of Open Access Journals (Sweden)

    Imran Amin

    2015-01-01

    Full Text Available A semiautomated extraction protocol of HCV-RNA using Favorgen RNA extraction kit has been developed. The kit provided protocol was modified by replacing manual spin steps with vacuum filtration. The assay performance was evaluated by real-time qPCR based on Taqman technology. Assay linearity was confirmed with the serial dilutions of RTA (Turkey containing 1 × (106, 105, 104, and 103 IU mL−1. Comparison of test results obtained by two extraction methods showed a good correlation (r=0.95, n=30 with detection limit of 102 IU mL−1. The semiautomated vacuum filtration based protocol demonstrated high throughput: 35 minutes for the extraction of a batch of 30 samples (150 µL each with reduced labor, time, waste, and cost. Performance characteristics of semiautomated system make it suitable for use in diagnostic purpose and viral load determinations.

  15. Effect of plasma processing reactor circuitry on plasma characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Rauf, S.; Kushner, M.J. [Univ. of Illinois, Urbana, IL (United States). Dept. of Electrical and Computer Engineering

    1997-12-31

    It is well known that external circuitry greatly influences the performance of plasma processing reactors. Simulation of external circuits difficult since the time in which the external circuit attains the steady-state is several orders of magnitude longer than typical plasma simulation time scales. In this paper, the authors present a technique to simulate the external circuit concurrently with the plasma, and implement it into the Hybrid Plasma Equipment Model (HPEM). The resulting model is used to investigate the influence of external circuitry on plasma behavior.

  16. Numerical simulation of dusty plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Winske, D.

    1995-09-01

    The numerical simulation of physical processes in dusty plasmas is reviewed, with emphasis on recent results and unresolved issues. Three areas of research are discussed: grain charging, weak dust-plasma interactions, and strong dust-plasma interactions. For each area, we review the basic concepts that are tested by simulations, present some appropriate examples, and examine numerical issues associated with extending present work.

  17. Plasma retinol and association with socio-demographic and dietary characteristics of free-living older persons: the Bordeaux sample of the three-city study.

    Science.gov (United States)

    Féart, Catherine; Siewe, Aisha; Samieri, Cécilia; Peuchant, Evelyne; Helmer, Catherine; Alfos, Serge; Pallet, Véronique; Barberger-Gateau, Pascale

    2010-01-01

    The objective was to describe retinol plasma concentration and its association with socio-demographic characteristics and dietary habits in French older persons. The study population consisted of 1664 subjects aged 65 + from Bordeaux (France), included in the Three-City cohort. Retinol plasma concentration was determined in fasting blood samples. Dietary assessment was performed by a food frequency questionnaire allowing estimation of weekly intake of dietary sources of vitamin A or provitamin A. The weekly number of glasses of alcohol was also recorded. Age, sex, marital status, educational and income levels, body-mass index (BMI), and smoking were registered. Cross-sectional analysis of the association between plasma retinol and socio-demographic characteristics and dietary habits was performed by multilinear regression. Mean plasma retinol was close to the homeostatically regulated concentration of 2.0 micromol/L but ranged from 0.35 to 6.77 micromol/L. It was higher in women and divorced or separated individuals, and increased with income but not with age or educational level. Plasma retinol was positively and independently associated with the frequency of offal consumption and to the number of glasses of alcohol consumed per week. These results allow targeting older individuals who are at risk of either excessive or deficient vitamin A status and who should benefit from dietary counseling.

  18. Radioimmunoassay of sodium cromoglycate in human plasma

    Energy Technology Data Exchange (ETDEWEB)

    Brown, K.; Gardner, J.J.; Lockley, W.J.S.; Preston, J.R.; Wilkinson, D.J. (Fisons Ltd., Loughborough (UK). Pharmaceutical Div.)

    1983-01-01

    A sensitive radioimmunoassay method for sodium cromoglycate in human plasma is described. The lowest quantifiable concentration of sodium cromoglycate is 0.93 nmol/1 when 0.1 ml plasma samples are analysed. Direct analysis of sodium cromoglycate concentrations in plasma samples collected up to several hours after the administration of single therapeutic doses of the compound is possible. The range of the method is limited; both 0.01 and 0.1 ml volumes of plasma must be analysed to encompass the concentration range 0.93-139 nmol/1 which may be encountered in plasma samples from patients and human volunteers. The method is specific for sodium cromoglycate as indicated by a low cross-reactivity of the anti-cromoglycate antiserum with a number of drugs.

  19. Plasma impregnation of wood with fire retardants

    Science.gov (United States)

    Pabeliña, Karel G.; Lumban, Carmencita O.; Ramos, Henry J.

    2012-02-01

    The efficacy of chemical and plasma treatments with phosphate and boric compounds, and nitrogen as flame retardants on wood are compared in this study. The chemical treatment involved the conventional method of spraying the solution over the wood surface at atmospheric condition and chemical vapor deposition in a vacuum chamber. The plasma treatment utilized a dielectric barrier discharge ionizing and decomposing the flame retardants into innocuous simple compounds. Wood samples are immersed in either phosphoric acid, boric acid, hydrogen or nitrogen plasmas or a plasma admixture of two or three compounds at various concentrations and impregnated by the ionized chemical reactants. Chemical changes on the wood samples were analyzed by Fourier transform infrared spectroscopy (FTIR) while the thermal changes through thermo gravimetric analysis (TGA). Plasma-treated samples exhibit superior thermal stability and fire retardant properties in terms of highest onset temperature, temperature of maximum pyrolysis, highest residual char percentage and comparably low total percentage weight loss.

  20. The Plasma Archipelago: Plasma Physics in the 1960s

    Science.gov (United States)

    Weisel, Gary J.

    2017-09-01

    With the foundation of the Division of Plasma Physics of the American Physical Society in April 1959, plasma physics was presented as the general study of ionized gases. This paper investigates the degree to which plasma physics, during its first decade, established a community of interrelated specialties, one that brought together work in gaseous electronics, astrophysics, controlled thermonuclear fusion, space science, and aerospace engineering. It finds that, in some regards, the plasma community was indeed greater than the sum of its parts and that its larger identity was sometimes glimpsed in inter-specialty work and studies of fundamental plasma behaviors. Nevertheless, the plasma specialties usually worked separately for two inter-related reasons: prejudices about what constituted "basic physics," both in the general physics community and within the plasma community itself; and a compartmentalized funding structure, in which each funding agency served different missions.

  1. Slurry micro-sampling technique for use in argon-helium microwave induced plasma optical emission spectrometry.

    Science.gov (United States)

    Ślachciński, Mariusz

    2016-12-01

    The Flow Focusing Pneumatic Nebulizer (FFPN) working at low liquid flow rates was evaluated for the elemental analysis in slurried samples by argon-helium microwave induced plasma optical emission spectrometry (MIP-OES). The obtained results achieved were compared with commercially available V-groove Babington type nebulizer (VBPN). A univariate approach and the simplex optimization procedure were used to achieve optimized conditions and derive analytical figures of merit. Analytical performance of the micro nebulization system was characterized by a determination of the limits of detection (LODs), the precision (RSDs) and the wash-out times for Ba, Ca, Cd, Cu, Fe, Mg, Mn, Pb and Sr. The experimental concentration detection limits for simultaneous determination, calculated as the concentration giving a signal equal to three times of the standard deviation of the blank (LOD, 3σblank criterion, peak height) were 0.9, 0.2, 0.3, 0.2, 0.3, 0.1, 0.2, 0.4, 0.4 and 0.3ngmL(-1) for Ba, Ca, Cd, Cu, Fe, Mg, Mn, Pb and Sr, respectively. The method offers relatively good precision (RSD ranged from 5% to 8%) for micro-slurry sampling analysis. Analyses of the certified reference materials (NRCC DOLT-2, GBW 07302 and SRM 2710) were performed in order to determine the accuracy available with the presented nebulization systems. The measured contents of elements in the reference materials were in satisfactory agreement with the certified values. In addition, these elements were determined in two real samples. Slurry concentration up to 3% m/v (particles technique. An ultrasonic probe was used to homogenize the slurry in the polypropylene bottle just before its introduction into the nebulizer. The nebulizers exhibited no clogging problems. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Speciation of gadolinium in surface water samples and plants by hydrophilic interaction chromatography hyphenated with inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Lindner, Uwe; Lingott, Jana; Richter, Silke; Jakubowski, Norbert; Panne, Ulrich

    2013-02-01

    Hydrophilic interaction chromatography (HILIC) coupled with inductively coupled plasma mass spectrometry (ICP-MS) was optimized for speciation analysis of gadolinium-based contrast agents in environmental samples, in particular surface river waters and plants. Surface water samples from the Teltow channel, near Berlin, were investigated over a distance of 5 km downstream from the influx of a wastewater treatment plant. The total concentration of gadolinium increased significantly from 50 to 990 ng L(-1) due to the influx of the contrast agents. After complete mixing with the river water, the concentration remained constant over a distance of at least 4 km. Two main substances [Dotarem(®) (Gd-DOTA) and Gadovist(®) (Gd-BT-DO3A)] have been identified in the river water using standards. A gadolinium-based contrast agent, possibly Gd-DOTA (Dotarem(®)), was also detected in water plant samples taken from the Teltow channel. Therefore, uptake of contrast agents [Gadovist(®) (Gd-BTDO3A), Magnevist(®) (Gd-DTPA), Omniscan(®) (Gd-DTPA-BMA), Dotarem(®) (Gd-DOTA), and Multihance(®) (Gd-BOPTA)] by plants was investigated in a model experiment using Lepidium sativum (cress plants). HILIC-ICP-MS was used for identification of different contrast agents, and a first approach for quantification using aqueous standard solutions was tested. For speciation analysis, all investigated contrast agents could be extracted from the plant tissues with a recovery of about 54 % for Multihance(®) (Gd-BOPTA) up to 106 % for Gadovist(®) (Gd-BT-DO3A). These experiments demonstrate that all contrast agents investigated are transported from the roots to the leaves where the highest content was measured.

  3. Pharmacokinetics of tulathromycin in plasma and milk samples after a single subcutaneous injection in lactating goats (Capra hircus).

    Science.gov (United States)

    Grismer, B; Rowe, J D; Carlson, J; Wetzlich, S E; Tell, L A

    2014-04-01

    Eight adult female dairy goats received one subcutaneous administration of tulathromycin at a dosage of 2.5 mg/kg body weight. Blood and milk samples were assayed for tulathromycin and the common fragment of tulathromycin, respectively, using liquid chromatography/mass spectrometry. Pharmacokinetic disposition of tulathromycin was analyzed by a noncompartmental approach. Mean plasma pharmacokinetic parameters (±SD) following single-dose administration of tulathromycin were as follows: C(max) (121.54 ± 19.01 ng/mL); T(max) (12 ± 12-24 h); area under the curve AUC(0→∞) (8324.54 ± 1706.56 ng·h/mL); terminal-phase rate constant λz (0.01 ± 0.002 h⁻¹); and terminal-phase rate constant half-life t1/2λz (67.20 h; harmonic). Mean milk pharmacokinetic parameters (±SD) following 45 days of sampling were as follows: Cmax (1594 ± 379.23 ng/mL); Tmax (12 ± 12-36 h); AUC(0→∞) (72,250.51 ± 18,909.57 ng·h/mL); λz (0.005 ± 0.001 h⁻¹); and t(1/2λz) (155.28 h; harmonic). All goats had injection-site reactions that diminished in size over time. The conclusions from this study were that tulathromycin residues are detectable in milk samples from adult goats for at least 45 days following subcutaneous administration, this therapeutic option should be reserved for cases where other treatment options have failed, and goat milk should be withheld from the human food chain for at least 45 days following tulathromycin administration.

  4. Direct trace-elemental analysis of urine samples by laser ablation-inductively coupled plasma mass spectrometry after sample deposition on clinical filter papers.

    Science.gov (United States)

    Aramendía, Maite; Rello, Luis; Vanhaecke, Frank; Resano, Martín

    2012-10-16

    Collection of biological fluids on clinical filter papers shows important advantages from a logistic point of view, although analysis of these specimens is far from straightforward. Concerning urine analysis, and particularly when direct trace elemental analysis by laser ablation-inductively coupled plasma mass spectrometry (LA-ICPMS) is aimed at, several problems arise, such as lack of sensitivity or different distribution of the analytes on the filter paper, rendering obtaining reliable quantitative results quite difficult. In this paper, a novel approach for urine collection is proposed, which circumvents many of these problems. This methodology consists on the use of precut filter paper discs where large amounts of sample can be retained upon a single deposition. This provides higher amounts of the target analytes and, thus, sufficient sensitivity, and allows addition of an adequate internal standard at the clinical lab prior to analysis, therefore making it suitable for a strategy based on unsupervised sample collection and ulterior analysis at referral centers. On the basis of this sampling methodology, an analytical method was developed for the direct determination of several elements in urine (Be, Bi, Cd, Co, Cu, Ni, Sb, Sn, Tl, Pb, and V) at the low μg L(-1) level by means of LA-ICPMS. The method developed provides good results in terms of accuracy and LODs (≤1 μg L(-1) for most of the analytes tested), with a precision in the range of 15%, fit-for-purpose for clinical control analysis.

  5. Sequential cloud point extraction of trace elements from biological samples and determination by inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Gine, Maria Fernanda; Patreze, Aparecida F.; Silva, Edson L. [Centro de Energia Nuclear na Agricultura (CENA-USP), Piracicaba, SP (Brazil)]. E-mail: mfgine@cena.usp.br; Sarkis, Jorge E.S.; Kakazu, Mauricio H. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2008-07-01

    A two-step sequential cloud point extraction (CPE) of trace elements from small sample volumes of human serum, animal blood, and food diet is proposed to gain analytical information in the analysis by inductively coupled plasma mass spectrometry. The first CPE was attained by adding O,O-diethyldithiophosphate, the non ionic surfactant Triton{sup R} X-114 followed by heating at 40 deg C, centrifugation and cooling at 0 deg C. The resulting surfactant-rich phase was separated to determine Cd, Pb and Cu by isotope dilution. Isotope ratio measurements presented RSD < 0.7%. The residual surfactant-poor phase solution had the pH adjusted in the range 4 to 5 before the chelating reagent, 4-(2-pyridylazo) resorcinol plus surfactant Triton{sup R} X-114 were added followed by the sequence to attain the CPE. Co and Ni were quantified in the second extracted surfactant-rich phases by standard additions method with RSD < 2%. Recoveries from 85 to 96% were obtained for all elements. Analyzing reference materials with certified and recommended values assessed accuracy. (author)

  6. Plasma preparation and storage for African elephants (Loxodonta africana).

    Science.gov (United States)

    Knauf, Sascha; Blad-Stahl, Julia; Lawrenz, Arne; Schuerer, Ulrich; Wehrend, Axel

    2009-03-01

    The use of plasma as a life-saving tool for neonatal African elephants (Loxodonta africana) that failed passive transfer of immunoglobulins is proposed. The methodology of blood sampling, plasma extraction, and plasma storage is described. Values for cellular component sedimentation and biochemical parameters of extracted plasma that was collected from 2 female elephants is presented. The proposal for a central plasma bank for elephants in European zoos is suggested.

  7. The Plasma Chemistry of Polymer Surfaces

    CERN Document Server

    Friedrich, Jö

    2012-01-01

    This book illustrates plasma properties, polymer characteristics, surface specifics, and how to purposefully combine plasma and polymer chemistry. In so doing, it covers plasma polymerization, surface functionalization, etching, crosslinking, and deposition of monotype functional-group-bearing plasma polymers. It explains different techniques and plasma types, such as pressure-pulsed, remote, low-wattage plasmas and plasma polymerization in liquids. Finally, among the numerous applications discussed are plasmas for chemical synthesis, industrial processes or the modification of membranes and p

  8. Modulational interactions in quantum plasmas

    CERN Document Server

    Sayed, Fatema; Tyshetskiy, Yuriy; Ishihara, Osamu

    2013-01-01

    A formalism for treating modulational interactions of electrostatic fields in collisionless quantum plasmas is developed, based on the kinetic Wigner-Poisson model of quantum plasma. This formalism can be used in a range of problems of nonlinear interaction between electrostatic fields in a quantum plasma, such as development of turbulence, self-organization, as well as transition from the weak turbulent state to strong turbulence. In particular, using this formalism, we obtain the kinetic quantum Zakharov equations, that describe nonlinear coupling of high frequency Langmuir waves to low frequency plasma density variations, for cases of non-degenerate and degenerate plasma electrons.

  9. Experimental plasma research project summaries

    Energy Technology Data Exchange (ETDEWEB)

    1978-08-01

    This report contans descriptions of the activities supported by the Experimental Plasma Research Branch of APP. The individual project summaries were prepared by the principal investigators and include objectives and milestones for each project. The projects are arranged in six research categories: Plasma Properties; Plasma Heating; Plasma Measurements and Instrumentation; Atomic, Molecular and Nuclear Physics; Advanced Superconducting Materials; and the Fusion Plasma Research Facility (FPRF). Each category is introduced with a statement of objectives and recent progress and followed by descriptions of individual projects. An overall budget summary is provided at the beginning of the report.

  10. Experimental Plasma Research project summaries

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-09-01

    This report contains descriptions of the activities supported by the Experimental Plasma Research Branch of APP. The individual project summaries were prepared by the principal investigators and include objectives and milestones for each project. The projects are arranged in six research categories: Plasma Properties; Plasma Heating; Plasma Diagnostics; Atomic, Molecular and Nuclear Physics; Advanced Superconducting Materials; and the Fusion Plasma Research Facility (FPRF). Each category is introduced with a statement of objectives and recent progress and followed by descriptions of individual projects. An overall budget summary is provided at the beginning of the report.

  11. Plasma chemistry for inorganic materials

    Science.gov (United States)

    Matsumoto, O.

    1980-01-01

    Practical application of plasma chemistry to the development of inorganic materials using both low temperature and warm plasmas are summarized. Topics cover: the surface nitrification and oxidation of metals; chemical vapor deposition; formation of minute oxide particles; the composition of oxides from chloride vapor; the composition of carbides and nitrides; freezing high temperature phases by plasma arc welding and plasma jet; use of plasma in the development of a substitute for petroleum; the production of silicon for use in solar cell batteries; and insulating the inner surface of nuclear fusion reactor walls.

  12. Plasma devices for hydrocarbon reformation

    KAUST Repository

    Cha, Min Suk

    2017-02-16

    Plasma devices for hydrocarbon reformation are provided. Methods of using the devices for hydrocarbon reformation are also provided. The devices can include a liquid container to receive a hydrocarbon source, and a plasma torch configured to be submerged in the liquid. The plasma plume from the plasma torch can cause reformation of the hydrocarbon. The device can use a variety of plasma torches that can be arranged in a variety of positions in the liquid container. The devices can be used for the reformation of gaseous hydrocarbons and/or liquid hydrocarbons. The reformation can produce methane, lower hydrocarbons, higher hydrocarbons, hydrogen gas, water, carbon dioxide, carbon monoxide, or a combination thereof.

  13. Basics of plasma astrophysics

    CERN Document Server

    Chiuderi, Claudio

    2015-01-01

    This book is an introduction to contemporary plasma physics that discusses the most relevant recent advances in the field and covers a careful choice of applications to various branches of astrophysics and space science. The purpose of the book is to allow the student to master the basic concepts of plasma physics and to bring him or her up to date in a number of relevant areas of current research. Topics covered include orbit theory, kinetic theory, fluid models, magnetohydrodynamics, MHD turbulence, instabilities, discontinuities, and magnetic reconnection. Some prior knowledge of classical physics is required, in particular fluid mechanics, statistical physics, and electrodynamics. The mathematical developments are self-contained and explicitly detailed in the text. A number of exercises are provided at the end of each chapter, together with suggestions and solutions.

  14. Adiabatic plasma buncher

    Energy Technology Data Exchange (ETDEWEB)

    Ferrario, M. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Frascati, Frascati, RM (Italy); Katsouleas, T.C. [Los Angeles Univ. of Southern California, Los Angeles, CA (United States); Serafini, L. [Istituto Nazionale di Fisica Nucleare, Milan (Italy); Ben Zvi, I. [Brookhaven National Laboratory, Upton, NY (United States)

    2000-07-01

    In this paper is presented a new scheme of injection into a plasma accelerator, aimed at producing a high quality beam while relaxing the demands on the bunch length of the injected beam. The beam dynamics in the injector, consisting of a high voltage pulsed photo-diode, is analyzed and optimized to produce a {lambda}{sub p}/20 long electron bunch at 2.5 MeV. This bunch is injected into a plasma wave in which it compresses down to {lambda}{sub p}/100 while simultaneously accelerating up to 250 MeV. This simultaneous bunching and acceleration of a high quality beam requires a proper combination of injection energy and injection phase. Preliminary results from simulations are shown to assess the potentials of the scheme.

  15. Neutrino beam plasma instability

    Indian Academy of Sciences (India)

    Vishnu M Bannur

    2001-10-01

    We derive relativistic fluid set of equations for neutrinos and electrons from relativistic Vlasov equations with Fermi weak interaction force. Using these fluid equations, we obtain a dispersion relation describing neutrino beam plasma instability, which is little different from normal dispersion relation of streaming instability. It contains new, nonelectromagnetic, neutrino-plasma (or electroweak) stable and unstable modes also. The growth of the instability is weak for the highly relativistic neutrino flux, but becomes stronger for weakly relativistic neutrino flux in the case of parameters appropriate to the early universe and supernova explosions. However, this mode is dominant only for the beam velocity greater than 0.25 and in the other limit electroweak unstable mode takes over.

  16. Cosmic Plasma Wakefield Acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Chen, P

    2004-04-26

    Recently we proposed a new cosmic acceleration mechanism which was based on the wakefields excited by the Alfven shocks in a relativistically owing plasma. In this paper we include some omitted details, and show that there exists a threshold condition for transparency below which the accelerating particle is collision-free and suffers little energy loss in the plasma medium. The stochastic encounters of the random accelerating-decelerating phases results in a power-law energy spectrum: f({epsilon}) {proportional_to} 1/{epsilon}{sup 2}. As an example, we discuss the possible production of super-GZK ultra high energy cosmic rays (UHECR) in the atmosphere of gamma ray bursts. The estimated event rate in our model agrees with that from UHECR observations.

  17. Plasma Trytophan and Sleep

    Science.gov (United States)

    Chen, C. N.; Kalucy, R. S.; Hartmann, M. K.; Lacey, J. H.; Crisp, A. H.; Bailey, J. E.; Eccleston, E. G.; Coppen, A.

    1974-01-01

    Free, bound, and total plasma tryptophan (F.P.T., B.P.T., and T.P.T.) levels have been measured throughout the night in six young female volunteers. All-night polygraphic sleep recordings were also made. No direct temporal relationship was found between plasma tryptophan levels and specific sleep stages. The mean F.P.T. levels, however, were found to have a positive correlation with rapid-eye-movement (R.E.M.) sleep and a negative correlation with non-R.E.M. sleep. An inverse relationship existed between the F.P.T. and B.P.T. levels. There appeared to be a diurnal variation in F.P.T. levels, with high readings in the first half of the night. PMID:4373116

  18. Microinstabilities in stellarator plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Rafiq, T.; Nasim, M.H.; Persson, M. [Department of Electromagnetics and Euratom/VR Association, Chalmers University of Technology, Goeteborg (Sweden)

    2003-07-01

    Linear stability and localization of ion temperature gradient modes in fully 3-dimensional stellarator plasmas is calculated in the electrostatic limit. A ballooning mode formalism with WKB assumption is applied to reduce the equations into ordinary differential equation along the field lines which are solved numerically for different plasma parameters. The results are correlated with the geometrical effects such as magnetic curvature, local magnetic shear and its integrated value along the field line and the effects of trapped electrons are also investigated. The eigenfunctions of the most unstable modes are found to be localized but the nodes in the amplitude of the eigenfunctions may be large depending upon the location on the magnetic surface. The results are compared and contrasted with calculations in tokamak geometry and the implications on future stellarator design is also discussed. (orig.)

  19. Plasma dust crystallization

    Science.gov (United States)

    Goree, John; Thomas, H.; Morfill, G.

    1994-01-01

    In a ground-based definition study, a concept for a new type of microgravity experiment is developed. We formed a new state of matter: a crystalline lattice structure of charged micron-size spheres, suspended in a charge-neutral plasma. The plasma is formed by a low-pressure radio-frequency argon discharge. Solid microspheres are introduced, and they gain a negative electric charge. They are cooled by molecular drag on the ambient neutral gas. They are detected by laser light scattering and video photography. Laboratory experiments have demonstrated that a two-dimensional nonquantum lattice forms through the Coulomb interaction of these spheres. Microgravity is thought to be required to observe a three-dimensional structure.

  20. Theoretical plasma physics

    Science.gov (United States)

    Boozer, A. H.; Vahala, G. M.

    1992-05-01

    Work during the past year in the areas of classical and anomalous transport, three-dimensional equilibria, divertor physics, and diagnostic techniques using waves is reported. Although much work was done on classical transport, the validity of the guiding-center drift equations, which are the basis of much of the theory, has received little attention. The limitations of the drift approximation are being studied. Work on three-dimensional equilibria, which shows that quasi-helical symmetry is broken in third order in the inverse aspect ratio, on the modification of the current profile due to tearing modes was completed. This work is relevant to the maintenance of a steady-state tokamak by the bootstrap current. Divertor physics is a primary area that required development for ITER. One of the few methods by which the physics of the divertor can be modified or controlled is magnetic perturbations. The effect of magnetic perturbations on the divertor scrapeoff layer in collaboration with Hampton University is being studied. The evolution of magnetic field embedded in a moving plasma is a dynamics problem of potential importance. Renormalization techniques gave important insights first in the theory of phase transitions. The applications of these techniques has extended to many areas of physics, including turbulence in fluids and plasmas. Essentially no diagnostics for magnetic fluctuations inside a fusion-grade plasma exist. A collaborative program with Old Dominion University and the Princeton Plasma Physics Laboratory to develop such a diagnostic based on the conversion of electromagnetic waves from the ordinary to the extraordinary mode is underway.

  1. Topics in Plasma Physics

    Energy Technology Data Exchange (ETDEWEB)

    Vahala, Linda [Old Dominion Univ., Norfolk, VA (United States)

    2015-05-31

    During the period 1998-2013, research under the auspices of the Department of Energy was performed on RF waves in plasmas. This research was performed in close collaboration with Josef Preinhaelter, Jakub Urban, Vladimir Fuchs, Pavol Pavlo and Frantisek Zacek (Czech Academy of Sciences), Martin Valovic and Vladimir Shevchenko (Culham). This research is detailed and all 38 papers which were published by this team are cited.

  2. Princeton Plasma Physics Laboratory:

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, C.A. (ed.)

    1986-01-01

    This paper discusses progress on experiments at the Princeton Plasma Physics Laboratory. The projects and areas discussed are: Principal Parameters Achieved in Experimental Devices, Tokamak Fusion Test Reactor, Princeton Large Torus, Princeton Beta Experiment, S-1 Spheromak, Current-Drive Experiment, X-ray Laser Studies, Theoretical Division, Tokamak Modeling, Spacecraft Glow Experiment, Compact Ignition Tokamak, Engineering Department, Project Planning and Safety Office, Quality Assurance and Reliability, and Administrative Operations.

  3. Dusty plasma (Yukawa) rings

    CERN Document Server

    Sheridan, T E

    2010-01-01

    One-dimensional and quasi-one-dimensional strongly-coupled dusty plasma rings have been created experimentally. Longitudinal (acoustic) and transverse (optical) dispersion relations for the 1-ring were measured and found to be in very good agreement with the theory for an unbounded straight chain of particles interacting through a Yukawa (i.e., screened Coulomb or Debye-H\\"uckel) potential. These rings provide a new system in which to study one-dimensional and quasi-one-dimensional physics.

  4. Plasma antioxidants from chocolate

    OpenAIRE

    Serafini, M; Bugianesi, R.; Maiani, G.; Valtuena, S.; De Santis, S.; Crozier, A.

    2003-01-01

    There is some speculation that dietary flavonoids from chocolate, in particular (-)epicatechin, may promote cardiovascular health as a result of direct antioxidant effects or through antithrombotic mechanisms. Here we show that consumption of plain, dark chocolate results in an increase in both the total antioxidant capacity and the (-)epicatechin content of blood plasma, but that these effects are markedly reduced when the chocolate is consumed with milk or if milk is incorporated as milk ch...

  5. Relativistic spherical plasma waves

    CERN Document Server

    Bulanov, S S; Schroeder, C B; Zhidkov, A G; Esarey, E; Leemans, W P

    2011-01-01

    Tightly focused laser pulses as they diverge or converge in underdense plasma can generate wake waves, having local structures that are spherical waves. Here we report on theoretical study of relativistic spherical wake waves and their properties, including wave breaking. These waves may be suitable as particle injectors or as flying mirrors that both reflect and focus radiation, enabling unique X-ray sources and nonlinear QED phenomena.

  6. Dense Plasma Focus Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Li, Hui [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Li, Shengtai [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Jungman, Gerard [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hayes-Sterbenz, Anna Catherine [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-08-31

    The mechanisms for pinch formation in Dense Plasma Focus (DPF) devices, with the generation of high-energy ions beams and subsequent neutron production over a relatively short distance, are not fully understood. Here we report on high-fidelity 2D and 3D numerical magnetohydrodynamic (MHD) simulations using the LA-COMPASS code to study the pinch formation dynamics and its associated instabilities and neutron production.

  7. Plasma Processing of Materials

    Science.gov (United States)

    1985-02-22

    used in France. In this case, three ’ movable electrodes arranged about the central axis with a coaxial sheath gas are employed. Initially the...Demiocratic Republic plasma furnace. chrome -magnesite; the bottom section is lined with rammed chrome -magnesite refractory. Due to the high heat loads... sheath injector design, cathode tip shape, and degree of water cooling are important parameters in providing a stable, uncontaminating, long-lifetime

  8. Air plasma effect on dental disinfection

    Energy Technology Data Exchange (ETDEWEB)

    Duarte, S.; Murata, R. M.; Saxena, D. [Department of Basic Sciences and Craniofacial Biology, College of Dentistry, New York University, New York, New York 10010 (United States); Kuo, S. P.; Chen, C. Y.; Huang, K. J. [Department of Electrical and Computer Engineering, Polytechnic Institute of New York University, Brooklyn, New York 11202 (United States); Popovic, S. [Department of Physics, Old Dominion University, Norfolk, Virginia 23529 (United States)

    2011-07-15

    A nonthermal low temperature air plasma jet is characterized and applied to study the plasma effects on oral pathogens and biofilms. Experiments were performed on samples of six defined microorganisms' cultures, including those of gram-positive bacteria and fungi, and on a cultivating biofilm sample of Streptococcus mutans UA159. The results show that the plasma jet creates a zone of microbial growth inhibition in each treated sample; the zone increases with the plasma treatment time and expands beyond the entire region directly exposed to the plasma jet. With 30s plasma treatment twice daily during 5 days of biofilm cultivation, its formation was inhibited. The viability of S. mutans cells in the treated biofilms dropped to below the measurable level and the killed bacterial cells concentrated to local regions as manifested by the fluorescence microscopy via the environmental scanning electron microscope. The emission spectroscopy of the jet indicates that its plasma effluent carries an abundance of reactive atomic oxygen, providing catalyst for the observed plasma effect.

  9. Air plasma effect on dental disinfection

    Science.gov (United States)

    Duarte, S.; Kuo, S. P.; Murata, R. M.; Chen, C. Y.; Saxena, D.; Huang, K. J.; Popovic, S.

    2011-07-01

    A nonthermal low temperature air plasma jet is characterized and applied to study the plasma effects on oral pathogens and biofilms. Experiments were performed on samples of six defined microorganisms' cultures, including those of gram-positive bacteria and fungi, and on a cultivating biofilm sample of Streptococcus mutans UA159. The results show that the plasma jet creates a zone of microbial growth inhibition in each treated sample; the zone increases with the plasma treatment time and expands beyond the entire region directly exposed to the plasma jet. With 30s plasma treatment twice daily during 5 days of biofilm cultivation, its formation was inhibited. The viability of S. mutans cells in the treated biofilms dropped to below the measurable level and the killed bacterial cells concentrated to local regions as manifested by the fluorescence microscopy via the environmental scanning electron microscope. The emission spectroscopy of the jet indicates that its plasma effluent carries an abundance of reactive atomic oxygen, providing catalyst for the observed plasma effect.

  10. Plasma is a strategic resource.

    Science.gov (United States)

    Strengers, Paul F W; Klein, Harvey G

    2016-12-01

    Plasma-derived medicinal products (PDMPs) such as immunoglobulins and clotting factors are listed by the World Health Organization as essential medicines. These and other PDMPs are crucial for the prophylaxis and treatment of patients with bleeding disorders, immune deficiencies, autoimmune and inflammatory diseases, and a variety of congenital deficiency disorders. While changes in clinical practice in developed countries have reduced the need for red blood cell transfusions thereby significantly reducing the collection volumes of whole blood and recovered plasma suitable for fractionation, the need for PDMPs worldwide continues to increase. The majority of plasma supplies for the manufacture of PDMPs is met by the US commercial plasma industry. However, geographic imbalance in the collection of plasma raises concerns that local disruptions of plasma supplies could result in regional and global shortages of essential PDMPs. Plasma, which fits the definition of a strategic resource, that is, "an economically important raw material which is subject to a higher risk of supply interruption," should be considered a strategic resource comparable to energy and drinking water. Plasma collections should be increased outside the United States, including in low- and middle-income countries. The need for capacity building in these countries is an essential part to strengthen quality plasma collection. This will require changes in national and regional policies. We advocate the need for the restoration of an equitable balance of the international plasma supply to reduce the risk of supply shortages worldwide. Strategic independence of plasma should be endorsed on a global level. © 2016 AABB.

  11. Electrosurgical Plasma Discharges

    Science.gov (United States)

    Stalder, K. R.; Woloszko, J.

    2002-10-01

    Electrosurgical instruments employing plasmas to volumetrically ablate tissue are now enjoying widespread use in medical applications. We have studied several commercially available instruments in which luminous plasma discharges are formed near electrodes immersed in saline solutions when sufficiently large amplitude bipolar voltage waveforms are applied. Different aqueous salt solutions have been investigated, including isotonic NaCl solution as well as solutions of KCl, and BaCl_2. With strong driving voltage applied, a vapor layer is formed as well as visible and UV optical emissions. Spectroscopic measurements reveal the predominant emissions are from the low ionization potential salt species, but significant emissions from electron impact dissociated water fragments such as OH and H-atoms also are observed. The emissions also coincide with negative bias on the active electrode. These optical emissions are consistent with an electron density of about 10^12cm-3 and an electron temperature of about 4 eV. Experimental results and model calculations of the vapor layer formation process and plasma formation in the high-field region will be discussed.

  12. Sterilization by oxygen plasma

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Adir Jose; Mansano, Ronaldo Domingues; Andreoli Pinto, Terezinha de Jesus; Ruas, Ronaldo; Silva Zambon, Luis da; Silva, Monica Valero da; Verdonck, Patrick Bernard

    2004-07-31

    The use of polymeric medical devices has stimulated the development of new sterilization methods. The traditional techniques rely on ethylene oxide, but there are many questions concerning the carcinogenic properties of the ethylene oxide residues adsorbed on the materials after processing. Another common technique is the gamma irradiation process, but it is costly, its safe operation requires an isolated site and it also affects the bulk properties of the polymers. The use of a gas plasma is an elegant alternative sterilization technique. The plasma promotes an efficient inactivation of the micro-organisms, minimises the damage to the materials and presents very little danger for personnel and the environment. Pure oxygen reactive ion etching type of plasmas were applied to inactivate a biologic indicator, the Bacillus stearothermophilus, to confirm the efficiency of this process. The sterilization processes took a short time, in a few minutes the mortality was complete. In situ analysis of the micro-organisms' inactivating time was possible using emission spectrophotometry. The increase in the intensity of the 777.5 nm oxygen line shows the end of the oxidation of the biologic materials. The results were also observed and corroborated by scanning electron microscopy.

  13. Modeling electronegative plasma discharge

    Energy Technology Data Exchange (ETDEWEB)

    Lichtenberg, A.J.; Lieberman, M.A. [Univ. of California, Berkley, CA (United States)

    1995-12-31

    Macroscopic analytic models for a three-component electronegative gas discharge are developed. Assuming the negative ions to be in Boltzmann equilibrium, a positive ion ambipolar diffusion equation is derived. The discharge consists of an electronegative core and electropositive edges. The electron density in the core is nearly uniform, allowing a parabolic approximation to the plasma profile to be employed. The resulting equilibrium equations are solved analytically and matched to a constant mobility transport model of an electropositive edge plasma. The solutions are compared to a simulation of a parallel-plane r.f. driven oxygen plasma for p = 50 mTorr and n{sub eo}= 2.4 x 10{sup 15} m{sup -3}. The ratio {alpha}{sub o} of central negative ion density to electron density, and the electron temperature T{sub e}, found in the simulation, are in reasonable agreement with the values calculated from the model. The model is extended to: (1) low pressures, where a variable mobility model is used in the electropositive edge region; and (2) high {alpha}{sub o} in which the edge region disappears. The inclusion of a second positive ion species, which can be very important in describing electronegative discharges used for materials processing, is a possible extension of the model.

  14. PLASMA CELL LEUKEMIA

    Science.gov (United States)

    de Larrea, Carlos Fernandez; Kyle, Robert A.; Durie, Brian GM; Ludwig, Heinz; Usmani, Saad; Vesole, David H.; Hajek, Roman; Miguel, Jésus San; Sezer, Orhan; Sonneveld, Pieter; Kumar, Shaji K.; Mahindra, Anuj; Comenzo, Ray; Palumbo, Antonio; Mazumber, Amitabha; Anderson, Kenneth C.; Richardson, Paul G.; Badros, Ashraf Z.; Caers, Jo; Cavo, Michele; LeLeu, Xavier; Dimopoulos, Meletios A.; Chim, CS; Schots, Rik; Noeul, Amara; Fantl, Dorotea; Mellqvist, Ulf-Henrik; Landgren, Ola; Chanan-Khan, Asher; Moreau, Philippe; Fonseca, Rafael; Merlini, Giampaolo; Lahuerta, JJ; Bladé, Joan; Orlowski, Robert Z.; Shah, Jatin J.

    2014-01-01

    Plasma cell leukemia (PCL) is a rare and aggressive variant of myeloma characterized by the presence of circulating plasma cells. It is classified as either primary PCL occurring at diagnosis or as secondary PCL in patients with relapsed/refractory myeloma. Primary PCL is a distinct clinic-pathologic entity with different cytogenetic and molecular findings. The clinical course is aggressive with short remissions and survival duration. The diagnosis is based upon the percentage (≥ 20%) and absolute number (≥ 2 × 10 9/L) of plasma cells in the peripheral blood. It is proposed that the thresholds for diagnosis be reexamined and consensus recommendations are made for diagnosis, as well as, response and progression criteria. Induction therapy needs to begin promptly and have high clinical activity leading to rapid disease control in an effort to minimize the risk of early death. Intensive chemotherapy regimens and bortezomib-based regimens are recommended followed by high-dose therapy with autologous stem-cell transplantation (HDT/ASCT) if feasible. Allogeneic transplantation can be considered in younger patients. Prospective multicenter studies are required to provide revised definitions and better understanding of the pathogenesis of PCL. PMID:23288300

  15. Electron waves and resonances in bounded plasmas

    CERN Document Server

    Vandenplas, Paul E

    1968-01-01

    General theoretical methods and experimental techniques ; the uniform plasma slab-condenser system ; the hollow cylindrical plasma ; scattering of a plane electromagnetic wave by a plasma column in steady magnetic fields (cold plasma approximation) ; hot non-uniform plasma column ; metallic and dielectric resonance probes, plasma-dielectric coated antenna, general considerations.

  16. Rapid Changes in Circulating Tumor DNA in Serially Sampled Plasma During Treatment of Breast Cancer: A Case Report

    Science.gov (United States)

    Nakagomi, Hiroshi; Hirotsu, Yosuke; Amemiya, Kenji; Nakada, Haruka; Inoue, Masayuki; Mochizuki, Hitoshi; Oyama, Toshio; Omata, Masao

    2017-01-01

    Patient: Female, 45 Final Diagnosis: Breast cancer Symptoms: Breast tumor Medication: — Clinical Procedure: Analysis of circulating tumor DNA Specialty: Oncology Objective: Unusual setting of medical care Background: The analysis of circulating tumor DNA (ctDNA) is expected to be a modality to determine the status of cancer in real time. This case indicated utilities and issues in measuring the ctDNA in cancer patients. Case Report: A 45-year-old woman with metastatic breast cancer was treated with bevacizumab and paclitaxel. The lung metastases were decreased but the meningitis carcinoma developed rapidly and she died. During the treatment with bevacizumab and paclitaxel, blood samples were taken serially and ctDNA was analyzed using a next-generation sequencer. TP53 frameshift mutation (TP53; p.Arg158fs with 7 nucleotides deletion) was identified in the tumor, and dynamic change in this mutation in ctDNA was observed in serially sampled plasma in this patient. We observed a rapid decrease of TP53 mutation at the beginning of treatment, then it increased as a sign of relapse. However, the high allelic fraction value of TP53 mutation was not consistent during the progression of cancer, suggesting that several factors affected the value of ctDNA. Conclusions: Although this is a single-case experience, it strongly suggests ctDNA could be a modality to determine the cancer status in real time. However, we found that several factors affected the value of ctDNA. Further investigations are needed to reveal the significance of these very high-sensitivity changes. PMID:28065930

  17. Speciation of cisplatin in environmental water samples by hydrophilic interaction liquid chromatography coupled to inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Vidmar, Janja; Martinčič, Anže; Milačič, Radmila; Ščančar, Janez

    2015-06-01

    Cisplatin is still widely used for treatment of numerous types of tumours. Different speciation methods have been applied to study behaviour of the intact drug and its individual biotransformation species in various clinical samples. These methods are mainly based on electrophoresis, size exclusion (SEC) or ion chromatography (IC) techniques coupled to inductively coupled plasma mass spectrometry (ICP-MS). Hydrophilic interaction liquid chromatography (HILIC), which is a common technique for separation of polar substances, was rarely applied for separation of cisplatin and its hydrolysed metabolites. There is also a lack of information available on the occurrence of cisplatin and its hydrolysed complexes in the environmental waters. In the present study the concentrations of Pt were determined in hospital wastewaters by ICP-MS. A procedure for separation of cisplatin and its aqueous hydrolysed complexes by the use of HILIC column was optimized. Quantification of separated Pt species was performed by isotope dilution (ID)-ICP-MS procedure. Low limits of detection (LODs) and quantification (LOQs) were obtained for cisplatin and its hydrolysed complexes ranging from 0.0273 to 0.1726 ng Pt/mL and from 0.0909 to 0.5753 ng Pt/mL, respectively. Good repeatability of the procedure with relative standard deviation (RSD) lower than ±2.3% was obtained. The column recoveries, which ranged from 95 to 101%, indicated that the procedure developed enabled quantitative speciation analysis of aqueous cisplatin complexes. The ZIC-HILIC-ID-ICP-MS procedure was successfully applied in speciation of cisplatin in spiked hospital wastewater samples.

  18. Potential of Solid Sampling Electrothermal Vaporization for solving spectral interference in Inductively Coupled Plasma Optical Emission Spectrometry

    Science.gov (United States)

    Asfaw, Alemayehu; Wibetoe, Grethe

    2009-05-01

    Spectral interference is one of the main causes of erroneous results in Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES). This paper describes some cases of spectral interferences with conventional nebulization ICP-OES and the potential of solving them utilizing electrothermal vaporization for volatility-based separation. The cases studied were, the well-known spectral overlap between the As and Cd lines at 228.8 nm that are only 10 pm apart, and the interference of Fe on the main emission lines of As, Cd and Pb. The spectral interferences were studied by monitoring the typical signals of solutions that contain the analytes and the potential interferent, by studying the spectra and calculating Background Equivalent Concentration (BEC)-values. A three step temperature program was developed to be used for direct analysis of solid soil samples by Electrothermal Vaporization (ETV)-ICP-OES: step 1 (760 °C, 40 s), step 2 (1620 °C, 20 s) and a cleaning step (2250 °C, 10 s) where Cd vaporizes in step 1, As, Pb and part of Fe in step 2 and the major part of Fe in the cleaning step. Because As and Cd were time-separated using this program, their prominent lines at 228.8 nm, could be used for determination of each element by ETV-ICP-OES, in spite of the serious wavelength overlap. Selective vaporization was also shown to reduce or eliminate the Fe background emission on As, Cd and Pb lines. To confirm the applicability of the method, a solid soil certified reference materials was analyzed directly without any sample treatment. Good or reasonable accuracy was obtained for the three elements.

  19. Analytical sample preparation strategies for the determination of antimalarial drugs in human whole blood, plasma and urine

    DEFF Research Database (Denmark)

    Casas, Monica Escolà; Hansen, Martin; Krogh, Kristine A;

    2014-01-01

    Antimalarial drugs commonly referred to as antimalarials, include a variety of compounds with different physicochemical properties. There is a lack of information on antimalarial distribution in the body over time after administration, e.g. the drug concentrations in whole blood, plasma, and urin...... summarized. Finally, the main problems that the researchers have dealt with are highlighted. This information will aid analytical chemists in the development of novel methods for determining existing antimalarials and upcoming new drugs.......Antimalarial drugs commonly referred to as antimalarials, include a variety of compounds with different physicochemical properties. There is a lack of information on antimalarial distribution in the body over time after administration, e.g. the drug concentrations in whole blood, plasma, and urine...

  20. Proton driven plasma wakefield generation in a parabolic plasma channel

    Science.gov (United States)

    Golian, Y.; Dorranian, D.

    2016-11-01

    An analytical model for the interaction of charged particle beams and plasma for a wakefield generation in a parabolic plasma channel is presented. In the suggested model, the plasma density profile has a minimum value on the propagation axis. A Gaussian proton beam is employed to excite the plasma wakefield in the channel. While previous works investigated on the simulation results and on the perturbation techniques in case of laser wakefield accelerations for a parabolic channel, we have carried out an analytical model and solved the accelerating field equation for proton beam in a parabolic plasma channel. The solution is expressed by Whittaker (hypergeometric) functions. Effects of plasma channel radius, proton bunch parameters and plasma parameters on the accelerating processes of proton driven plasma wakefield acceleration are studied. Results show that the higher accelerating fields could be generated in the PWFA scheme with modest reductions in the bunch size. Also, the modest increment in plasma channel radius is needed to obtain maximum accelerating gradient. In addition, the simulations of longitudinal and total radial wakefield in parabolic plasma channel are presented using LCODE. It is observed that the longitudinal wakefield generated by the bunch decreases with the distance behind the bunch while total radial wakefield increases with the distance behind the bunch.

  1. Plasma Torch for Plasma Ignition and Combustion of Coal

    Science.gov (United States)

    Ustimenko, Alexandr; Messerle, Vladimir

    2015-09-01

    Plasma-fuel systems (PFS) have been developed to improve coal combustion efficiency. PFS is a pulverized coal burner equipped with arc plasma torch producing high temperature air stream of 4000 - 6000 K. Plasma activation of coal at the PFS increases the coal reactivity and provides more effective ignition and ecologically friendly incineration of low-rank coal. The main and crucial element of PFS is plasma torch. Simplicity and reliability of the industrial arc plasma torches using cylindrical copper cathode and air as plasma forming gas predestined their application at heat and power engineering for plasma aided coal combustion. Life time of these plasma torches electrodes is critical and usually limited to 200 hours. Considered in this report direct current arc plasma torch has the cathode life significantly exceeded 1000 hours. To ensure the electrodes long life the process of hydrocarbon gas dissociation in the electric arc discharge is used. In accordance to this method atoms and ions of carbon from near-electrode plasma deposit on the active surface of the electrodes and form electrode carbon condensate which operates as ``actual'' electrode. Complex physicochemical investigation showed that deposit consists of nanocarbon material.

  2. A New Liquid Chromatography-Tandem Mass Spectrometry Method for Determination of Bisoprolol in Human Plasma Samples

    OpenAIRE

    Gabriela Peste; Nela Bibire; Mihai Apostu; Aurel Vlase; Corneliu Oniscu

    2009-01-01

    Liquid chromatography (LC) coupled with mass spectrometry (MS) detection is one of the most powerful analytical tools for organic compound analysis. The advantages of using LC/MS methods over HPLC methods include: selectivity, chromatographic integrity, peak assignment, structural information, and rapid method development. In this paper, a new liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the determination of bisoprolol in human plasma s...

  3. Particle transport in a He-microchip plasma atomic emission system with an ultrasonic nebulizer for aqueous sample introduction

    Science.gov (United States)

    Oh, Joosuck; Lim, H. B.

    2008-11-01

    The transport efficiency of dried particles generated from an ultrasonic nebulizer (USN) was studied to improve the analytical performance of a lab-made, He-microchip plasma system, in which a quartz tube (~ 1 mm i.d.) was positioned inside the central channel of a poly(dimethylsiloxane) (PDMS) polymer chip. The polymer microchip plasma has the advantages of low cost, small size, easy handling and design, and self-ignition with long stabilization (> 24 h). However, direct introduction of aqueous solution into the microplasma for the detection of metals remains problematic due to plasma instability. In addition, the much smaller size of the system can cause signal suppression due to low transport efficiency. Therefore, knowledge of particle transport efficiency in this microplasma system is required to enhance the sensitivity and stability. The weight of transported particles in the range of 0.02 to 10 mg m - 3 was measured using a piezobalance with a precision of 0.4-17.8%, depending on the operating conditions. The significant effects of the USN operating conditions and the physical properties of the tubing, namely, length, inner diameter and surface characteristics, on the number of particles transported from the nebulizer to the microplasma were studied. When selected metals, such as Na, Mg and Pb, at a concentration of 5 mg L - 1 were nebulized, transported particles were obtained with a mass range of 0.5-5 mg m - 3 , depending on atomic weights. For application of the He-rf-microplasma, the atomic emission system was optimized by changing both the radio frequency (rf) power (60-200 W) and cooling temperature of the USN (- 12-9 °C). The limits of detection obtained for K, Na and Cu were 0.26, 0.22, and 0.28 mg L - 1 , respectively. These results confirmed the suitable stability and sensitivity of the He-rf-PDMS microchip plasma for application as an atomization source.

  4. An ultrasound-assisted digestion method for the determination of toxic element concentrations in ash samples by inductively coupled plasma optical emission spectrometry.

    Science.gov (United States)

    Ilander, Aki; Väisänen, Ari

    2007-10-29

    A method of ultrasound-assisted digestion followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of toxic element concentrations (arsenic, barium, cobalt, copper, lead, nickel, strontium, vanadium and zinc) in ash samples was developed. All the measurements were performed in robust plasma conditions which were tested by measuring the Mg(II) 280.270 nm/Mg(I) 285.213 nm line intensity ratios. The highest line intensity ratios were observed when a nebulizer gas flow of 0.6 L min(-1), auxiliary gas flow of 0.2 L min(-1) and plasma power of 1400 W were used for radially viewed plasma. The analysis of SRM 1633b showed that the ultrasound-assisted method developed is highly comparable with the microwave digestion method standardized by the United States Environmental Protection Agency (EPA-3052). The ultrasound-assisted digestion with a digestion solution of aqua regia and hydrofluoric acid (HF) resulted in recovery rates of over 81%. One exception is arsenic which resulted in recoveries of about 60% only; however, it could be digested with good recovery (>90%) using a digestion solution of 5 mL of water and 5 mL of aqua regia. The major advantage of the ultrasound-assisted digestion over microwave digestion is the high treatment rate (30 samples simultaneously with a sonication time of 18 min).

  5. Comparison of the Hologic Aptima HIV-1 Quant Dx Assay to the Roche COBAS Ampliprep/COBAS TaqMan HIV-1 Test v2.0 for the quantification of HIV-1 RNA in plasma samples

    DEFF Research Database (Denmark)

    Schønning, Kristian; Johansen, Kim; Landt, Bodil

    2017-01-01

    of the Aptima HIV-1 Quant Dx Assay (Aptima) and the COBAS Ampliprep/COBAS TaqMan HIV-1 Test v2.0 (CAPCTMv2) for the quantification of HIV-1 RNA in plasma samples. STUDY DESIGN: The performance of the two tests was compared on 216 clinical plasma samples, on dilutions series in seven replicates of five clinical...

  6. Speciation analysis by gas chromatography with plasma source spectrometric detection

    Science.gov (United States)

    Łobiński, Ryszard; Adams, Freddy C.

    State-of-the-art species-selective analysis by gas chromatography (GC) with plasma source spectrometric detection is discussed for organometal and organometalloid compounds. Various plasmas, inductively coupled plasma, microwave induced plasma, capacitatively coupled plasma, direct current plasma and alternating current plasma, are characterized and critically compared as sources of radiation for atomic emission spectrometry and sources of ions for mass spectrometry. Interfaces between gas chromatography (packed, wide-bore, capillary and multicapillary) and plasma source spectrometry are characterized. Particular emphasis is given to applications of GC with plasma source detection to real-world analytical problems, which are comprehensively reviewed. The use of plasmas for the acquisition of auxiliary molecular information such as empirical formulae and structural information is discussed. Recent developments relating to sample preparation and presentation to the hyphenated system are addressed. The most significant trends in speciation analysis are highlighted.

  7. Determination of extremely low (236)U/(238)U isotope ratios in environmental samples by sector-field inductively coupled plasma mass spectrometry using high-efficiency sample introduction.

    Science.gov (United States)

    Boulyga, Sergei F; Heumann, Klaus G

    2006-01-01

    A method by inductively coupled plasma mass spectrometry (ICP-MS) was developed which allows the measurement of (236)U at concentration ranges down to 3 x 10(-14)g g(-1) and extremely low (236)U/(238)U isotope ratios in soil samples of 10(-7). By using the high-efficiency solution introduction system APEX in connection with a sector-field ICP-MS a sensitivity of more than 5,000 counts fg(-1) uranium was achieved. The use of an aerosol desolvating unit reduced the formation rate of uranium hydride ions UH(+)/U(+) down to a level of 10(-6). An abundance sensitivity of 3 x 10(-7) was observed for (236)U/(238)U isotope ratio measurements at mass resolution 4000. The detection limit for (236)U and the lowest detectable (236)U/(238)U isotope ratio were improved by more than two orders of magnitude compared with corresponding values by alpha spectrometry. Determination of uranium in soil samples collected in the vicinity of Chernobyl nuclear power plant (NPP) resulted in that the (236)U/(238)U isotope ratio is a much more sensitive and accurate marker for environmental contamination by spent uranium in comparison to the (235)U/(238)U isotope ratio. The ICP-MS technique allowed for the first time detection of irradiated uranium in soil samples even at distances more than 200 km to the north of Chernobyl NPP (Mogilev region). The concentration of (236)U in the upper 0-10 cm soil layers varied from 2 x 10(-9)g g(-1) within radioactive spots close to the Chernobyl NPP to 3 x 10(-13)g g(-1) on a sampling site located by >200 km from Chernobyl.

  8. Online plasma diagnostics of a laser-produced plasma

    Science.gov (United States)

    Kai, Gao; Nasr, A. M. Hafz; Song, Li; Mohammad, Mirzaie; Guangyu, Li; Quratul, Ain

    2017-01-01

    In this study, we report a laser interferometry experiment for the online-diagnosing of a laser-produced plasma. The laser pulses generating the plasma are ultra-fast (30 femtoseconds), ultra-intense (tens of Terawatt) and are focused on a helium gas jet to generate relativistic electron beams via the laser wakefield acceleration (LWFA) mechanism. A probe laser beam (λ = 800 nm) which is split-off the main beam is used to cross the plasma at the time of arrival of the main pulse, allowing online plasma density diagnostics. The interferometer setup is based on the NoMarski method in which we used a Fresnel bi-prism where the probe beam interferes with itself after crossing the plasma medium. A high-dynamic range CCD camera is used to record the interference patterns. Based upon the Abel inversion technique, we obtained a 3D density distribution of the plasma density.

  9. Clinical use of Plasma and Plasma Fractions in Bleeding Disorders

    Institute of Scientific and Technical Information of China (English)

    王兆钺

    2008-01-01

    Internal and/or external bleeding is a common and sometimes very severe clinical manifestations of disorders of hemostasis. It may follow minor trauma or may arise apparently spontaneously. Disorders of hemostasis are generally divided into those caused by abnormalities of platelets, abnormalities of blood vessels, abnormalities of plasma coagulation factors, and hyperfibrinolysis, or com-binations of these. The use of plasma and plasma fractions dependents on the causing diseases and their severity. Several plasma products and plasma fractions are availa-ble in China and other plasma components and deriva-tives are commercially obtained. There have been the guidelines for their clinical use, and the revised ones will soon be published by Chinese Medical Association.

  10. Determination of trace elements in water samples by ultrasonic nebulization inductively coupled plasma mass spectrometry after cloud point extraction

    Science.gov (United States)

    Mesquita da Silva, Márcia Andreia; Azzolin Frescura, Vera Lúcia; Curtius, Adilson José

    2000-07-01

    A preconcentration method for low concentrations of Ag, As, Au, Cd, Cu, Pb and Se in water, using cloud point extraction is proposed. The analytes in the initial aqueous solution, acidified with hydrochloric acid, are complexed with ammonium O, O-diethyl-dithiophosphate, and 0.05% m/v Triton X-114 is added as surfactant. The complexation allows the separation of the analytes from alkali, alkaline earth and other elements, which are not complexed. After phase separation, by increasing the temperature above 20°C, depending on the cloud point of the mixture, and dilution of the surfactant-rich phase with a mixture of 60% v/v methanol and 40% v/v of 1% v/v aqueous nitric acid solution, the enriched analytes are determined by inductively coupled plasma mass spectrometry, using ultrasonic nebulization, injecting 100 μl of the enriched phase with a flow injection (FI) system. Since the initial volume is 40 ml and the final volume is 1 ml, good enrichment factors are obtained. After optimization of the complexation (pH and DDTP concentration), of extraction conditions, sample introduction (FI and ultrasonic nebulizer parameters) and spectrometer conditions, the method was applied to the analysis of riverine water, sea water and enriched water reference materials, and good agreement with the certified values was obtained. By introducing the organic extract with the FI system and using ultrasonic nebulization, no carbon deposits on the interface cones and lens were observed, allowing extensive use of the spectrometer without cleaning and re-optimization.

  11. Multicomponent kinetic spectrophotometric determination of pefloxacin and norfloxacin in pharmaceutical preparations and human plasma samples with the aid of chemometrics

    Science.gov (United States)

    Ni, Yongnian; Wang, Yong; Kokot, Serge

    2008-10-01

    A spectrophotometric method for the simultaneous determination of the important pharmaceuticals, pefloxacin and its structurally similar metabolite, norfloxacin, is described for the first time. The analysis is based on the monitoring of a kinetic spectrophotometric reaction of the two analytes with potassium permanganate as the oxidant. The measurement of the reaction process followed the absorbance decrease of potassium permanganate at 526 nm, and the accompanying increase of the product, potassium manganate, at 608 nm. It was essential to use multivariate calibrations to overcome severe spectral overlaps and similarities in reaction kinetics. Calibration curves for the individual analytes showed linear relationships over the concentration ranges of 1.0-11.5 mg L -1 at 526 and 608 nm for pefloxacin, and 0.15-1.8 mg L -1 at 526 and 608 nm for norfloxacin. Various multivariate calibration models were applied, at the two analytical wavelengths, for the simultaneous prediction of the two analytes including classical least squares (CLS), principal component regression (PCR), partial least squares (PLS), radial basis function-artificial neural network (RBF-ANN) and principal component-radial basis function-artificial neural network (PC-RBF-ANN). PLS and PC-RBF-ANN calibrations with the data collected at 526 nm, were the preferred methods—%RPE T ˜ 5, and LODs for pefloxacin and norfloxacin of 0.36 and 0.06 mg L -1, respectively. Then, the proposed method was applied successfully for the simultaneous determination of pefloxacin and norfloxacin present in pharmaceutical and human plasma samples. The results compared well with those from the alternative analysis by HPLC.

  12. Abelianization of QCD plasma instabilities

    Science.gov (United States)

    Arnold, Peter; Lenaghan, Jonathan

    2004-12-01

    QCD plasma instabilities appear to play an important role in the equilibration of quark-gluon plasmas in heavy-ion collisions in the theoretical limit of weak coupling (i.e. asymptotically high energy). It is important to understand what nonlinear physics eventually stops the exponential growth of unstable modes. It is already known that the initial growth of plasma instabilities in QCD closely parallels that in QED. However, once the unstable modes of the gauge fields grow large enough for non-Abelian interactions between them to become important, one might guess that the dynamics of QCD plasma instabilities and QED plasma instabilities become very different. In this paper, we give suggestive arguments that non-Abelian self-interactions between the unstable modes are ineffective at stopping instability growth, and that the growing non-Abelian gauge fields become approximately Abelian after a certain stage in their growth. This in turn suggests that understanding the development of QCD plasma instabilities in the nonlinear regime may have close parallels to similar processes in traditional plasma physics. We conjecture that the physics of collisionless plasma instabilities in SU(2) and SU(3) gauge theory becomes equivalent, respectively, to (i) traditional plasma physics, which is U(1) gauge theory, and (ii) plasma physics of U(1)×U(1) gauge theory.

  13. The diverse applications of plasma

    Science.gov (United States)

    Sharma, Mukul; Dubey, Shivani; Darwhekar, Gajanan; Jain, Sudhir Kumar

    2015-07-01

    Plasma being the fourth state of matter has always been an attraction for Physicists and Chemists. With the advent of time, plasma energy has been recognized in having widening horizons in the field of Biomedical Sciences. Plasma medicine can be subdivided into three main fields; Non-thermal atmospheric-pressure direct plasma for medical therapy; Plasma-assisted modification of bio-relevant surfaces and Plasma-based bio-decontamination and sterilization. The basis of the research is that as it has free carrier molecules, it has the ability to target specific cells and regulate functions like wound healing. Plasma does not harm healthy human cells but can kill bacteria and possibly even cancer cells to help treat various diseases. Nosocomial infection control, prevention and containment of contagious diseases, disinfection of medical devices, surface treatment (heat and UV sensitive surfaces) are research of interest. Recent success in generating plasma at very low temperature ie. Cold plasma makes the therapy painless. It has the ability to activate cellular responses and important mechanisms in the body. They target specific molecules such as prothrombin for blood coagulation, cytokines for killing bacteria, and angiogenesis for tissue regeneration. Plasma has bactericidal, fungicidal and virucidal properties. Plasma technology has flourishing future in diverse fields like Textiles, Nanofabrication, Automotives, Waste management, Microbiology, Food Hygiene, Medical Science like Skin treatments, sterilisation of wounds, Hand disinfection, Dental treatments etc. Food hygiene using plasma can be achieved in disinfection of food containers, food surface disinfection, hygiene in food handling, preparation and packaging. Therefore Plasma is most promising field for budding Scientist for fluorishing research in Biological Sciences.

  14. The diverse applications of plasma

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Mukul, E-mail: mukulsharma@acropolis.edu.in; Darwhekar, Gajanan, E-mail: gdarwhekar@acropolis.edu.in [Acropolis Institute of Pharmaceutical Education & Research, Indore MP India (India); Dubey, Shivani, E-mail: dubeyshivani08@rediffmail.com [Mata Gujri College of Professional Studies, Indore MP India (India); Jain, Sudhir Kumar, E-mail: sudhirkjain1@rediffmail.com [School of Studies in Microbiology, Vikram University, Ujjain MP India (India)

    2015-07-31

    Plasma being the fourth state of matter has always been an attraction for Physicists and Chemists. With the advent of time, plasma energy has been recognized in having widening horizons in the field of Biomedical Sciences. Plasma medicine can be subdivided into three main fields; Non-thermal atmospheric-pressure direct plasma for medical therapy; Plasma-assisted modification of bio-relevant surfaces and Plasma-based bio-decontamination and sterilization. The basis of the research is that as it has free carrier molecules, it has the ability to target specific cells and regulate functions like wound healing. Plasma does not harm healthy human cells but can kill bacteria and possibly even cancer cells to help treat various diseases. Nosocomial infection control, prevention and containment of contagious diseases, disinfection of medical devices, surface treatment (heat and UV sensitive surfaces) are research of interest. Recent success in generating plasma at very low temperature ie. Cold plasma makes the therapy painless. It has the ability to activate cellular responses and important mechanisms in the body. They target specific molecules such as prothrombin for blood coagulation, cytokines for killing bacteria, and angiogenesis for tissue regeneration. Plasma has bactericidal, fungicidal and virucidal properties. Plasma technology has flourishing future in diverse fields like Textiles, Nanofabrication, Automotives, Waste management, Microbiology, Food Hygiene, Medical Science like Skin treatments, sterilisation of wounds, Hand disinfection, Dental treatments etc. Food hygiene using plasma can be achieved in disinfection of food containers, food surface disinfection, hygiene in food handling, preparation and packaging. Therefore Plasma is most promising field for budding Scientist for fluorishing research in Biological Sciences.

  15. Lightweight Portable Plasma Medical Device - Plasma Engineering Research Laboratory

    Science.gov (United States)

    2013-10-01

    sensitive surfaces. In this paper, the consumed power for plasma generation (plasma power) has been estimated from voltage-current waveform analysis in... consumed power for plasma generation is calculated by integrating the product of the discharge voltage and current over one cycle; according to the...Faculty Symposium: Course Design for the Millennial Student, Texas A&M University – Corpus Christi, 2011. (Showcased by the Center for Faculty

  16. Lightweight Portable Plasma Medical Device - Plasma Engineering Research Laboratory

    Science.gov (United States)

    2015-12-01

    research associates. The PI and the research team have published over 10 journal articles and over 50 conference proceedings and over 50 symposiums...reflections. Optical interference filters with center wavelength at 5322 or 632.82 nm are used in front of the ICCD to suppress the plasma self- luminescence ...wavelength at 532 ± 2 nm was used in front of the ICCD to suppress the plasma jet self- luminescence . The shadow of the laser induced plasma falls onto

  17. Determination of benzocaine in rainbow trout plasma

    Science.gov (United States)

    Bernardy, Jeffery A.; Coleman, K.S.; Stehly, G.R.; Gingerich, William H.

    1996-01-01

    A liquid chromatographic method is described for analysis of benzocaine (BZ), a proposed fish anesthetic, in rainbow trout plasma, Mean recoveries of BZ from plasma samples fortified at 44-10 100 ng/mL were 96-100%. The method detection limit is 10 ng/mL, and the limit of quantitation is 37 ng/mL. Acetylation of BZ occurs in whole blood after storage at room temperature (i.e., 21 degrees C) for 10 min. However, no acetylation of BZ was detected in plasma samples held at room temperature for 4 h, Mean method precision for plasma samples with incurred BZ residue is similar to that for fortified samples in the same concentration range (relative standard deviations of 0.9 and 1.2%, respectively).

  18. Radiochemical Separation and Measurement by Mass Spectrometry with Magnetic Sector with Inductively Coupled Plasma source (ICP-SFMS of Plutonium Isotopes in Soil Samples

    Directory of Open Access Journals (Sweden)

    C. O. Torres-Cortés

    2016-08-01

    Full Text Available The aim of this work is twofold: to optimize the radiochemical separation of Plutonium (Pu from soil samples, and to measure the Pu concentration. Soil samples were prepared using acid digestion assisted by microwaves; then, Pu purification was carried out with Pu AG1X8 resin. Pu isotopes were measured using Mass Spectrometry with Magnetic Sector with Inductively Coupled Plasma source (ICP-SFMS. In order to reduce the interference due to the presence of 238UH+ in the samples a desolvation system (Apex was used. The limit of detection (LOD of Pu was determined. The efficiency of Pu recovery from soil samples varies from 70 to 93%.

  19. Direct analysis of samples by mass spectrometry: From elements to bio-molecules using laser ablation inductively couple plasma mass spectrometry and laser desorption/ionization mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Perdian, David C. [Iowa State Univ., Ames, IA (United States)

    2009-01-01

    Mass spectrometric methods that are able to analyze solid samples or biological materials with little or no sample preparation are invaluable to science as well as society. Fundamental research that has discovered experimental and instrumental parameters that inhibit fractionation effects that occur during the quantification of elemental species in solid samples by laser ablation inductively coupled plasma mass spectrometry is described. Research that determines the effectiveness of novel laser desorption/ionization mass spectrometric methods for the molecular analysis of biological tissues at atmospheric pressure and at high spatial resolution is also described. A spatial resolution is achieved that is able to analyze samples at the single cell level.

  20. Determination of metoprolol enantiomers in human plasma and saliva samples utilizing microextraction by packed sorbent and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Elmongy, Hatem; Ahmed, Hytham; Wahbi, Abdel-Aziz; Amini, Ahmad; Colmsjö, Anders; Abdel-Rehim, Mohamed

    2016-08-01

    A sensitive, accurate and reliable bioanalytical method for the enantioselective determination of metoprolol in plasma and saliva samples utilizing liquid chromatography-electrospray ionization tandem mass spectrometry was developed and validated. Human plasma and saliva samples were pretreated by microextraction by packed sorbent (MEPS) prior to analysis. A new MEPS syringe form with two inputs was used. Metoprolol enantiomers and internal standard pentycaine (IS) were eluted from MEPS sorbent using isopropanol after removal of matrix interferences using aliquots of 5% methanol in water. Complete separation of metoprolol enantiomers was achieved on a Cellulose-SB column (150 × 4.6 mm, 5 μm) using isocratic elution with mobile phase 0.1% ammonium hydroxide in hexane-isopropanol (80:20, v/v) with a flow rate of 0.8 mL/min. A post-column solvent-assisted ionization was applied to enhance metoprolol ionization signal in positive mode monitoring (+ES) using 0.5% formic acid in isopropanol at a flow rate of 0.2 mL/min. The total chromatographic run time was 10 min for each injection. The detection of metoprolol in plasma and saliva samples was performed using triple quadrupole tandem mass spectrometer in +ES under the following mass transitions: m/z 268.08 → 72.09 for metoprolol and m/z 303.3 → 154.3 for IS. The linearity range was 2.5-500 ng/mL for both R- and S-metoprolol in plasma and saliva. The limits of detection and quantitation for both enantiomers were 0.5 and 2.5 ng/mL respectively, in both matrices (plasma and saliva). The intra- and inter-day precisions were presented in terms of RSD values for replicate analysis of quality control samples and were metoprolol enantiomers in both human plasma and saliva samples successfully, which can aid in therapeutic drug monitoring in clinical laboratories. Copyright © 2016 John Wiley & Sons, Ltd.

  1. A contoured gap coaxial plasma gun with injected plasma armature

    Science.gov (United States)

    Witherspoon, F. Douglas; Case, Andrew; Messer, Sarah J.; Bomgardner, Richard; Phillips, Michael W.; Brockington, Samuel; Elton, Raymond

    2009-08-01

    A new coaxial plasma gun is described. The long term objective is to accelerate 100-200 μg of plasma with density above 1017 cm-3 to greater than 200 km/s with a Mach number above 10. Such high velocity dense plasma jets have a number of potential fusion applications, including plasma refueling, magnetized target fusion, injection of angular momentum into centrifugally confined mirrors, high energy density plasmas, and others. The approach uses symmetric injection of high density plasma into a coaxial electromagnetic accelerator having an annular gap geometry tailored to prevent formation of the blow-by instability. The injected plasma is generated by numerous (currently 32) radially oriented capillary discharges arranged uniformly around the circumference of the angled annular injection region of the accelerator. Magnetohydrodynamic modeling identified electrode profiles that can achieve the desired plasma jet parameters. The experimental hardware is described along with initial experimental results in which approximately 200 μg has been accelerated to 100 km/s in a half-scale prototype gun. Initial observations of 64 merging injector jets in a planar cylindrical testing array are presented. Density and velocity are presently limited by available peak current and injection sources. Steps to increase both the drive current and the injected plasma mass are described for next generation experiments.

  2. A contoured gap coaxial plasma gun with injected plasma armature.

    Science.gov (United States)

    Witherspoon, F Douglas; Case, Andrew; Messer, Sarah J; Bomgardner, Richard; Phillips, Michael W; Brockington, Samuel; Elton, Raymond

    2009-08-01

    A new coaxial plasma gun is described. The long term objective is to accelerate 100-200 microg of plasma with density above 10(17) cm(-3) to greater than 200 km/s with a Mach number above 10. Such high velocity dense plasma jets have a number of potential fusion applications, including plasma refueling, magnetized target fusion, injection of angular momentum into centrifugally confined mirrors, high energy density plasmas, and others. The approach uses symmetric injection of high density plasma into a coaxial electromagnetic accelerator having an annular gap geometry tailored to prevent formation of the blow-by instability. The injected plasma is generated by numerous (currently 32) radially oriented capillary discharges arranged uniformly around the circumference of the angled annular injection region of the accelerator. Magnetohydrodynamic modeling identified electrode profiles that can achieve the desired plasma jet parameters. The experimental hardware is described along with initial experimental results in which approximately 200 microg has been accelerated to 100 km/s in a half-scale prototype gun. Initial observations of 64 merging injector jets in a planar cylindrical testing array are presented. Density and velocity are presently limited by available peak current and injection sources. Steps to increase both the drive current and the injected plasma mass are described for next generation experiments.

  3. Electron density and plasma dynamics of a colliding plasma experiment

    Energy Technology Data Exchange (ETDEWEB)

    Wiechula, J., E-mail: wiechula@physik.uni-frankfurt.de; Schönlein, A.; Iberler, M.; Hock, C.; Manegold, T.; Bohlender, B.; Jacoby, J. [Plasma Physics Group, Institute of Applied Physics, Goethe University, 60438 Frankfurt am Main (Germany)

    2016-07-15

    We present experimental results of two head-on colliding plasma sheaths accelerated by pulsed-power-driven coaxial plasma accelerators. The measurements have been performed in a small vacuum chamber with a neutral-gas prefill of ArH{sub 2} at gas pressures between 17 Pa and 400 Pa and load voltages between 4 kV and 9 kV. As the plasma sheaths collide, the electron density is significantly increased. The electron density reaches maximum values of ≈8 ⋅ 10{sup 15} cm{sup −3} for a single accelerated plasma and a maximum value of ≈2.6 ⋅ 10{sup 16} cm{sup −3} for the plasma collision. Overall a raise of the plasma density by a factor of 1.3 to 3.8 has been achieved. A scaling behavior has been derived from the values of the electron density which shows a disproportionately high increase of the electron density of the collisional case for higher applied voltages in comparison to a single accelerated plasma. Sequences of the plasma collision have been taken, using a fast framing camera to study the plasma dynamics. These sequences indicate a maximum collision velocity of 34 km/s.

  4. The Plasma Environment at Mercury

    Science.gov (United States)

    Raines, James M.; Gershman, Daniel J.; Zurbuchen, Thomas H.; Gloeckler, George; Slavin, James A.; Anderson, Brian J.; Korth, Haje; Krimigis, Stamatios M.; Killen, Rosemary M.; Sarantos, Menalos; hide

    2011-01-01

    Mercury is the least explored terrestrial planet, and the one subjected to the highest flux of solar radiation in the heliosphere. Its highly dynamic, miniature magnetosphere contains ions from the exosphere and solar wind, and at times may allow solar wind ions to directly impact the planet's surface. Together these features create a plasma environment that shares many features with, but is nonetheless very different from, that of Earth. The first in situ measurements of plasma ions in the Mercury space environment were made only recently, by the Fast Imaging Plasma Spectrometer (FIPS) during the MESSENGER spacecraft's three flybys of the planet in 2008-2009 as the probe was en route to insertion into orbit about Mercury earlier this year. Here. we present analysis of flyby and early orbital mission data with novel techniques that address the particular challenges inherent in these measurements. First. spacecraft structures and sensor orientation limit the FIPS field of view and allow only partial sampling of velocity distribution functions. We use a software model of FIPS sampling in velocity space to explore these effects and recover bulk parameters under certain assumptions. Second, the low densities found in the Mercury magnetosphere result in a relatively low signal-to-noise ratio for many ions. To address this issue, we apply a kernel density spread function to guide removal of background counts according to a background-signature probability map. We then assign individual counts to particular ion species with a time-of-flight forward model, taking into account energy losses in the carbon foil and other physical behavior of ions within the instrument. Using these methods, we have derived bulk plasma properties and heavy ion composition and evaluated them in the context of the Mercury magnetosphere.

  5. Plasma Beam Measurements

    Science.gov (United States)

    1991-08-01

    GUN PLASMA BEAM / ,I 21 cm diameter = 0 GLASS DRIFT TUBE 50 cm diameter MCP CAMERA CLASS CROSSES (a) Gun muzzle /"- PLASA BEAM / TAROT z = 10 m MCP...discusses some of the hydrodynamic issues related to the calcula- tions. The reader may well wonder why hydrodynamics should be an issue in a 116 WL-TR-90...answer is yes for the slow beam cases and no for the fast beam cases. This is explained further. 118 WL-TR-90-83 The reader will recall the

  6. Flexible plasma linear antenna

    Science.gov (United States)

    Zhao, Jiansen; Wang, Shengzheng; Wu, Huafeng; Liu, Yue; Chang, Yongmeng; Chen, Xinqiang

    2017-02-01

    In this work, we introduce a type of plasma antenna that was fabricated using flexible materials and excited using a 5-20 kHz alternating current (ac) power supply. The results showed that the antenna characteristics, including the impedance, the reflection coefficient (S11), the radiation pattern, and the gain, can be controlled rapidly and easily by varying both the discharge parameters and the antenna shapes. The scope for reconfiguration is greatly enhanced when the antenna shape is changed from a monopole to a helix configuration. Additionally, the antenna polarization can also be adjusted by varying the antenna shapes.

  7. The control of TCV plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Lister, J.B.; Hofmann, F.; Moret, J.M. [Ecole Polytechnique Federale, Lausanne (Switzerland). Centre de Recherche en Physique des Plasma (CRPP)] [and others

    1996-07-01

    The general control of tokamak plasmas has evolved considerably over the last few years with an increase in the plasma pulse length, an increase in the control of additional heating and fuelling and an increase in the degree to which the shape of the plasma can be varied. The TCV tokamak is specifically designed to explore the operational benefits of plasma shaping over a wide variety of plasma shapes. Consequently, considerable attention has been given to the control of the poloidal field coil currents which impose the desired shape. This paper deals with all aspects of the control of TCV plasmas, from the diagnostic measurements to the power supplies, via control algorithms and overall supervision. (author) 44 figs., tabs., 25 refs.

  8. MHD simulations of Plasma Jets and Plasma-surface interactions in Coaxial Plasma Accelerators

    Science.gov (United States)

    Subramaniam, Vivek; Raja, Laxminarayan

    2016-10-01

    Coaxial plasma accelerators belong to a class of electromagnetic acceleration devices which utilize a self-induced Lorentz force to accelerate magnetized thermal plasma to large velocities ( 40 Km/s). The plasma jet generated as a result, due to its high energy density, can be used to mimic the plasma-surface interactions at the walls of thermonuclear fusion reactors during an Edge Localized Mode (ELM) disruption event. We present the development of a Magnetohydrodynamics (MHD) simulation tool to describe the plasma acceleration and jet formation processes in coaxial plasma accelerators. The MHD model is used to study the plasma-surface impact interaction generated by the impingement of the jet on a target material plate. The study will characterize the extreme conditions generated on the target material surface by resolving the magnetized shock boundary layer interaction and the viscous/thermal diffusion effects. Additionally, since the plasma accelerator is operated in vacuum conditions, a novel plasma-vacuum interface tracking algorithm is developed to simulate the expansion of the high density plasma into a vacuum background in a physically consistent manner.

  9. Plasma diagnostics discharge parameters and chemistry

    CERN Document Server

    Auciello, Orlando

    1989-01-01

    Plasma Diagnostics, Volume 1: Discharge Parameters and Chemistry covers seven chapters on the important diagnostic techniques for plasmas and details their use in particular applications. The book discusses optical diagnostic techniques for low pressure plasmas and plasma processing; plasma diagnostics for electrical discharge light sources; as well as Langmuir probes. The text also describes the mass spectroscopy of plasmas, microwave diagnostics, paramagnetic resonance diagnostics, and diagnostics in thermal plasma processing. Electrical engineers, nuclear engineers, microwave engineers, che

  10. Cold plasma inactivation of chronic wound bacteria.

    Science.gov (United States)

    Mohd Nasir, N; Lee, B K; Yap, S S; Thong, K L; Yap, S L

    2016-09-01

    Cold plasma is partly ionized non-thermal plasma generated at atmospheric pressure. It has been recognized as an alternative approach in medicine for sterilization of wounds, promotion of wound healing, topical treatment of skin diseases with microbial involvement and treatment of cancer. Cold plasma used in wound therapy inhibits microbes in chronic wound due to its antiseptic effects, while promoting healing by stimulation of cell proliferation and migration of wound relating skin cells. In this study, two types of plasma systems are employed to generate cold plasma: a parallel plate dielectric barrier discharge and a capillary-guided corona discharge. Parameters such as applied voltage, discharge frequency, treatment time and the flow of the carrier gas influence the cold plasma chemistry and therefore change the composition and concentration of plasma species that react with the target sample. Chronic wound that fails to heal often infected by multidrug resistant organisms makes them recalcitrant to healing. Methicillin-resistant Staphylococcus aureus (MRSA) and Pseudomonas aeruginosa (Pseudomonas aeruginosa) are two common bacteria in infected and clinically non-infected wounds. The efficacies of the cold plasma generated by the two designs on the inactivation of three different isolates of MRSA and four isolates of P. aeruginosa are reported here.

  11. Plasma Sources for Medical Applications - A Comparison of Spot Like Plasmas and Large Area Plasmas

    Science.gov (United States)

    Weltmann, Klaus-Dieter

    2015-09-01

    Plasma applications in life science are currently emerging worldwide. Whereas today's commercially available plasma surgical technologies such as argon plasma coagulation (APC) or ablation are mainly based on lethal plasma effects on living systems, the newly emerging therapeutic applications will be based on selective, at least partially non-lethal, possibly stimulating plasma effects on living cells and tissue. Promising results could be obtained by different research groups worldwide revealing a huge potential for the application of low temperature atmospheric pressure plasma in fields such as tissue engineering, healing of chronic wounds, treatment of skin diseases, tumor treatment based on specific induction of apoptotic processes, inhibition of biofilm formation and direct action on biofilms or treatment of dental diseases. The development of suitable and reliable plasma sources for the different therapies requires an in-depth knowledge of their physics, chemistry and parameters. Therefore much basic research still needs to be conducted to minimize risk and to provide a scientific fundament for new plasma-based medical therapies. It is essential to perform a comprehensive assessment of physical and biological experiments to clarify minimum standards for plasma sources for applications in life science and for comparison of different sources. One result is the DIN-SPEC 91315, which is now open for further improvements. This contribution intends to give an overview on the status of commercial cold plasma sources as well as cold plasma sources still under development for medical use. It will discuss needs, prospects and approaches for the characterization of plasmas from different points of view. Regarding the manageability in everyday medical life, atmospheric pressure plasma jets (APPJ) and dielectric barrier discharges (DBD) are of special interest. A comprehensive risk-benefit assessment including the state of the art of commercial sources for medical use

  12. Plasma cell granuloma of lip

    Directory of Open Access Journals (Sweden)

    B Sabarinath

    2012-01-01

    Full Text Available Plasma cells are medium-sized round-to-oval cells with eccentrically placed nuclei, usually found in the red pulp of the spleen, tonsils, medulla of the lymph nodes, nasal mucosa, upper airway, lamina propria of the gastrointestinal tract, and sites of inflammation. Plasma cell granuloma is a rare reactive tumor-like proliferation composed chiefly of plasmacytic infiltrate. Here, we present a case of plasma cell granuloma of lip in a female patient.

  13. Supersonic Plasma Flow Control Experiments

    Science.gov (United States)

    2005-12-01

    to liquid metals , for example, the conductivities of typical plasma and electrolyte flows are relatively low. Ref. 14 cites the conductivity of...heating is the dominant effect. 15. SUBJECT TERMS Supersonic, plasma , MHD , boundary-layer 16. SECURITY CLASSIFICATION OF: 19a. NAME OF RESPONSIBLE...horns in operation on Mach 5 wind tunnel with a plasma discharge. 31 Figure 17 Front view of a 100 mA DC discharge generated with upstream pointing

  14. Computational Methods in Plasma Physics

    CERN Document Server

    Jardin, Stephen

    2010-01-01

    Assuming no prior knowledge of plasma physics or numerical methods, Computational Methods in Plasma Physics covers the computational mathematics and techniques needed to simulate magnetically confined plasmas in modern magnetic fusion experiments and future magnetic fusion reactors. Largely self-contained, the text presents the basic concepts necessary for the numerical solution of partial differential equations. Along with discussing numerical stability and accuracy, the author explores many of the algorithms used today in enough depth so that readers can analyze their stability, efficiency,

  15. Particle transport in a He-microchip plasma atomic emission system with an ultrasonic nebulizer for aqueous sample introduction

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Joosuck [Department of Chemistry, Dankook University, 126 Jukjeon-dong, Suji-gu, Yongin-si, Gyeonggi-do, 448-701 (Korea, Republic of); Lim, H.B. [Department of Chemistry, Dankook University, 126 Jukjeon-dong, Suji-gu, Yongin-si, Gyeonggi-do, 448-701 (Korea, Republic of)], E-mail: plasma@dankook.ac.kr

    2008-11-15

    The transport efficiency of dried particles generated from an ultrasonic nebulizer (USN) was studied to improve the analytical performance of a lab-made, He-microchip plasma system, in which a quartz tube ({approx} 1 mm i.d.) was positioned inside the central channel of a poly(dimethylsiloxane) (PDMS) polymer chip. The polymer microchip plasma has the advantages of low cost, small size, easy handling and design, and self-ignition with long stabilization (> 24 h). However, direct introduction of aqueous solution into the microplasma for the detection of metals remains problematic due to plasma instability. In addition, the much smaller size of the system can cause signal suppression due to low transport efficiency. Therefore, knowledge of particle transport efficiency in this microplasma system is required to enhance the sensitivity and stability. The weight of transported particles in the range of 0.02 to 10 mg m{sup -3} was measured using a piezobalance with a precision of 0.4-17.8%, depending on the operating conditions. The significant effects of the USN operating conditions and the physical properties of the tubing, namely, length, inner diameter and surface characteristics, on the number of particles transported from the nebulizer to the microplasma were studied. When selected metals, such as Na, Mg and Pb, at a concentration of 5 mg L{sup -1} were nebulized, transported particles were obtained with a mass range of 0.5-5 mg m{sup -3}, depending on atomic weights. For application of the He-rf-microplasma, the atomic emission system was optimized by changing both the radio frequency (rf) power (60-200 W) and cooling temperature of the USN (- 12-9 deg. C). The limits of detection obtained for K, Na and Cu were 0.26, 0.22, and 0.28 mg L{sup -1}, respectively. These results confirmed the suitable stability and sensitivity of the He-rf-PDMS microchip plasma for application as an atomization source.

  16. Autoresonant Excitation of Antiproton Plasmas

    Science.gov (United States)

    Andresen, G. B.; Ashkezari, M. D.; Baquero-Ruiz, M.; Bertsche, W.; Bowe, P. D.; Butler, E.; Carpenter, P. T.; Cesar, C. L.; Chapman, S.; Charlton, M.; Fajans, J.; Friesen, T.; Fujiwara, M. C.; Gill, D. R.; Hangst, J. S.; Hardy, W. N.; Hayden, M. E.; Humphries, A. J.; Hurt, J. L.; Hydomako, R.; Jonsell, S.; Madsen, N.; Menary, S.; Nolan, P.; Olchanski, K.; Olin, A.; Povilus, A.; Pusa, P.; Robicheaux, F.; Sarid, E.; Silveira, D. M.; So, C.; Storey, J. W.; Thompson, R. I.; van der Werf, D. P.; Wurtele, J. S.; Yamazaki, Y.

    2011-01-01

    We demonstrate controllable excitation of the center-of-mass longitudinal motion of a thermal antiproton plasma using a swept-frequency autoresonant drive. When the plasma is cold, dense, and highly collective in nature, we observe that the entire system behaves as a single-particle nonlinear oscillator, as predicted by a recent theory. In contrast, only a fraction of the antiprotons in a warm plasma can be similarly excited. Antihydrogen was produced and trapped by using this technique to drive antiprotons into a positron plasma, thereby initiating atomic recombination.

  17. Plasma placental lactogen in pregnancy.

    Science.gov (United States)

    Raghuramulu, N

    1978-01-01

    Plasma placental lactogen (HPL) and urinary oestrogen levels were investigated in pregnant women belonging to low and high socio-economic groups. Plasma HPL levels increased progressively with increasing gestation in women of both the socio-economic groups. The mean values in the two groups were not statistically different at any period of gestation. No correlation was observed between the birth weight of the infant and the maternal plasma placental lactogen levels at term. A positive correlation was observed between urinary oestrogen excretion and plasma HPL concentration.

  18. Autoresonant Excitation of Antiproton Plasmas

    CERN Document Server

    Andresen, Gorm B; Baquero-Ruiz, Marcelo; Bertsche, William; Bowe, Paul D; Butler, Eoin; Carpenter, P T; Cesar, Claudio L; Chapman, Steven; Charlton, Michael; Fajans, Joel; Friesen, Tim; Fujiwara, Makoto C; Gill, David R; Hangst, Jeffrey S; Hardy, Walter N; Hayden, Michael E; Humphries, Andrew J; Hurt, J L; Hydomako, Richard; Jonsell, Svante; Madsen, Niels; Menary, Scott; Nolan, Paul; Olchanski, Konstantin; Olin, Art; Povilus, Alexander; Pusa, Petteri; Robicheaux, Francis; Sarid, Eli; Silveira, Daniel M; So, Chukman; Storey, James W; Thompson, Robert I; van der Werf, Dirk P; Wurtele, Jonathan S; Yamazaki, Yasunori

    2011-01-01

    We demonstrate controllable excitation of the center-of-mass longitudinal motion of a thermal antiproton plasma using a swept-frequency autoresonant drive. When the plasma is cold, dense, and highly collective in nature, we observe that the entire system behaves as a single-particle nonlinear oscillator, as predicted by a recent theory. In contrast, only a fraction of the antiprotons in a warm plasma can be similarly excited. Antihydrogen was produced and trapped by using this technique to drive antiprotons into a positron plasma, thereby initiating atomic recombination.

  19. The Framework of Plasma Physics

    Science.gov (United States)

    Cowley, Steven

    There have been relatively few good textbooks on plasma physics. Most become simple reference books that might be titled, “Plasma Physics Recipes.” Despite their utility such books do not make good textbooks. For teaching, one needs a book that shows how the basic results and models are part of a coherent whole. Richard Hazeltine and Francois Waelbroeck have written such a textbook: The Framework of Plasma PhysicsAn this book, plasma physics is developed carefully and logically from basic physics principles. The book is not, however, overly formal; physical arguments are used to reduce mathematical complexity.

  20. Plasma cell granuloma of gingiva

    Directory of Open Access Journals (Sweden)

    Balaji Manohar

    2011-01-01

    Full Text Available Plasma cell granuloma is a rare benign lesion characterized by the infiltration of plasma cells; primarily occurring in the lungs. It is also seen to occur in the brain, kidney stomach, heart, and so on. In the intraoral region it is seen to involve the tongue, oral mucosa, and gingiva. This case presents a 42-year-old female, with an enlargement in the maxillary anterior region, treated by excisional biopsy. Histological evaluation revealed plasma cell infiltrates in the connective tissue. The immunohistochemistry revealed kappa and lambda light chains with a polyclonal staining pattern, which confirmed the diagnosis of plasma cell granuloma.

  1. Plasma on a foundry cupola

    Science.gov (United States)

    Pineau, Didier

    An experiment of a plasma torch on a production foundry cupola is reported. The test runs were conducted on a hot blast cupola, the blast temperature in the absence of plasma being 400 C. With the torch, the temperature of the blast was increased to 1000 C. The experiment was conducted for the manufacture of car engines with a 2.5 MW transportable plasma system. The cupola was boosted with a 4 MW torch and results included an increase in production of 45 percent, a decrease in coke rate and no more new iron in the loads. The plasma torch and hot air cupola furnace are described.

  2. Criticality in Plasma Membranes

    Science.gov (United States)

    Machta, Benjamin; Papanikolaou, Stefanos; Sethna, James; Veatch, Sarah

    2011-03-01

    We are motivated by recent observations of micron-sized critical fluctuations in the 2d Ising Universality class in plasma membrane vesicles that are isolated from cortical cytoskeleton. We construct a minimal model of the plasma membrane's interaction with intact cytoskeleton which explains why large scale phase separation has not been observed in Vivo. In addition, we use analytical techniques from conformal field theory and numerical simulations to investigate the form of effective forces mediated by the membrane's proximity to criticality. We show that the range of this force is maximized near a critical point and we quantify its usefulness in mediating communication using techniques from information theory. Finally we use theoretical techniques from statistical physics in conjunction with Monte-Carlo simulations to understand how criticality can be used to increase the efficiency of membrane bound receptor mediated signaling. We expect that this sort of analysis will be broadly useful in understanding and quantifying the role of lipid ``rafts'' in a wide variety of membrane bound processes. Generally, we demonstrate that critical fluctuations provide a physical mechanism to organize and spatially segregate membrane components by providing channels for interaction over relatively large distances.

  3. Measuring Kinetic Plasma Eigenmodes

    Science.gov (United States)

    Mattingly, Sean; Berumen, Jorge; Chu, Feng; Hood, Ryan; Skiff, Fred

    2015-11-01

    We present a method for measuring kinetic plasma eigenmodes of a cylindrical axially magnetized (1 kG) laboratory plasma (n ~109cm-3 , Te ~ 5eV , Ti ~ 0 . 06eV) by measuring velocity space correlation functions. This method simultaneously observes two separate laser induced fluorescence schemes. Each scheme has its own indepedently tunable laser and its own set of collection optics. With this setup, we are able to measure the time - averaged correlation function as a function of position on the cylindrical axis parallel to the magnetic field (z) and velocity on the deconvolved ion velocity distribution function (v) : C (z , v ,z' ,v' , τ) = t. The freedom of two lasers allows us to measure a two dimensional velocity correlation matrix. This matrix is investigated with the Vlasov equation in the collisionless and weakly collisional regime. The former case, which is continuous, is diagonalized with an integral transform defined by P. J. Morrison while the latter case, which is discrete, is diagonalized through the use of Hermite polynomials.

  4. Plasma Redshift Cosmology

    Science.gov (United States)

    Brynjolfsson, Ari

    2011-04-01

    The newly discovered plasma redshift cross section explains a long range of phenomena; including the cosmological redshift, and the intrinsic redshift of Sun, stars, galaxies and quasars. It explains the beautiful black body spectrum of the CMB, and it predicts correctly: a) the observed XRB, b) the magnitude redshift relation for supernovae, and c) the surface- brightness-redshift relation for galaxies. There is no need for Big Bang, Inflation, Dark Energy, Dark Matter, Accelerated Expansion, and Black Holes. The universe is quasi-static and can renew itself forever (for details, see: http://www.plasmaredshift.org). There is no cosmic time dilation. In intergalactic space, the average electron temperature is T = 2.7 million K, and the average electron density is N = 0.0002 per cubic cm. Plasma redshift is derived theoretically from conventional axioms of physics by using more accurate methods than those conventionally used. The main difference is: 1) the proper inclusion of the dielectric constant, 2) more exact calculations of imaginary part of the dielectric constant, and as required 3) a quantum mechanical treatment of the interactions.

  5. Quark gluon plasma

    CERN Document Server

    Nayak, Tapan; Sarkar, Sourav

    2014-01-01

    At extremely high temperatures and densities, protons and neutrons may dissolve into a "soup" of quarks and gluons, called the Quark-Gluon Plasma (QGP). For a few microseconds, shortly after the Big Bang, the Universe was filled with the QGP matter. The search and study of Quark-Gluon Plasma (QGP) is one of the most fundamental research topics of our times. The QGP matter has been probed by colliding heavy ions at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory, New York and the Large Hadron Collider at CERN, Geneva. By colliding heavy-ions at a speed close to that of light, scientists aim to obtain - albeit over a tiny volume of the size of a nucleus and for an infinitesimally short instant - a QGP state. This QGP state can be observed by dedicated experiments, as it reverts to hadronic matter through expansion and cooling. This volume presents some of the current theoretical and experimental understandings in the field of QGP.

  6. Theoretical Plasma Physics

    Energy Technology Data Exchange (ETDEWEB)

    Vahala, George M. [College of William and Mary, Williamsburg, VA (United States)

    2013-12-31

    Lattice Boltzmann algorithms are a mesoscopic method to solve problems in nonlinear physics which are highly parallelized – unlike the direction solution of the original problem. These methods are applied to both fluid and magnetohydrodynamic turbulence. By introducing entropic constraints one can enforce the positive definiteness of the distribution functions and so be able to simulate fluids at high Reynolds numbers without numerical instabilities. By introducing a vector distribution function for the magnetic field one can enforce the divergence free condition on the magnetic field automatically, without the need of divergence cleaning as needed in most direct numerical solutions of the resistive magnetohydrodynamic equations. The principal reason for the high parallelization of lattice Boltzmann codes is that they consist of a kinetic collisional relaxation step (which is purely local) followed by a simple shift of the relaxed data to neighboring lattice sites. In large eddy simulations, the closure schemes are highly nonlocal – the most famous of these schemes is that due to Smagorinsky. Under a lattice Boltzmann representation the Smagorinsky closure is purely local – being simply a particular moment on the perturbed distribution fucntions. After nonlocal fluid moment models were discovered to represent Landau damping, it was found possible to model these fluid models using an appropriate lattice Boltzmann algorithm. The close to ideal parallelization of the lattice Boltzmann codes permitted us to be Gordon Bell finalists on using the Earth Simulation in Japan. We have also been involved in the radio frequency propagation of waves into a tokamak and into a spherical overdense tokamak plasma. Initially we investigated the use of a quasi-optical grill for the launching of lower hybrid waves into a tokamak. It was found that the conducting walls do not prevent the rods from being properly irradiated, the overloading of the quasi-optical grill is not severe

  7. Analysis of drugs in plasma samples from schizophrenic patients by column-switching liquid chromatography-tandem mass spectrometry with organic-inorganic hybrid cyanopropyl monolithic column.

    Science.gov (United States)

    Domingues, Diego Soares; Souza, Israel Donizeti de; Queiroz, Maria Eugênia Costa

    2015-07-01

    This study reports on the development of a rapid, selective, and sensitive column-switching liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to analyze sixteen drugs (antidepressants, anticonvulsants, anxiolytics, and antipsychotics) in plasma samples from schizophrenic patients. The developed organic-inorganic hybrid monolithic column with cyanopropyl groups was used for the first dimension of the column-switching arrangement. This arrangement enabled online pre-concentration of the drugs (monolithic column) and their subsequent analytical separation on an XSelect SCH C18 column. The drugs were detected on a triple quadrupole tandem mass spectrometer (multiple reactions monitoring mode) with an electrospray ionization source in the positive ion mode. The developed method afforded adequate linearity for the sixteen target drugs; the coefficients of determination (R(2)) lay above 0.9932, the interassay precision had coefficients of variation lower than 6.5%, and the relative standard error values of the accuracy ranged from -14.0 to 11.8%. The lower limits of quantification in plasma samples ranged from 63 to 1250pgmL(-1). The developed method successfully analyzed the target drugs in plasma samples from schizophrenic patients for therapeutic drug monitoring (TDM).

  8. Comparison of sample preparation methods for the quantitative analysis of eicosanoids and other oxylipins in plasma by means of LC-MS/MS.

    Science.gov (United States)

    Ostermann, Annika I; Willenberg, Ina; Schebb, Nils Helge

    2015-02-01

    Oxylipins are potent lipid mediators. For the evaluation of their biological roles, several LC-MS based methods have been developed. While these methods are similar, the described sample preparation procedures for the extraction of oxylipins differ considerably. In order to deduce the most appropriate method for the analysis of non-esterified oxylipins in human plasma, we evaluated the performance of seven established sample preparation procedures. Six commonly used solid phase extraction (SPE) and one liquid-liquid extraction (LLE) protocol were compared based on the recovery of 13 added internal standards, extraction efficacy of oxylipins from plasma and reduction of ion-suppressing matrix. Dramatic differences in the performance in all three parameters were found. LLE with ethyl acetate was overall not a sufficient sample preparation strategy. The protocols using Oasis- and StrataX-material insufficiently removed interfering matrix compounds. Extraction efficacy of oxylipins on anion-exchanging BondElut cartridges was low, while removal of matrix was nearly perfect. None of the protocols led to a high extraction efficacy of analytes while removing all interfering matrix components. However, SPE on a C18-material with removal of matrix by water and n-hexane prior elution with methyl formate showed the best performance for the analysis of a broad spectrum of oxylipins in plasma.

  9. Molecularly imprinted polymer in microextraction by packed sorbent for the simultaneous determination of local anesthetics: lidocaine, ropivacaine, mepivacaine and bupivacaine in plasma and urine samples.

    Science.gov (United States)

    Daryanavard, Seyed Mosayeb; Jeppsson-Dadoun, Amin; Andersson, Lars I; Hashemi, Mahdi; Colmsjö, Anders; Abdel-Rehim, Mohamed

    2013-11-01

    This study presents the use of molecularly imprinted polymer (MIP) as packing material for microextraction by packed syringe (MEPS) to achieve higher extraction selectivity. Pentycaine was used as template for MIP. Development and validation of the determination of lidocaine, ropivacaine, mepivacaine and bupivacaine in human plasma and urine samples utilizing MIP-MEPS and liquid chromatography-tandem mass spectrometry (LC-MS/MS) were carried out. The MEPS MIP-cartridge could be used for 100 extractions before it was discarded. The extraction recovery ranged from 60 to 80%. The correlation coefficients values were >0.999 for all assays using lidocaine, ropivacaine, mepivacaine and bupivacaine in the calibration range 5-2000 nmol/L. The accuracy of the studied compounds, given as a percentage variation from the nominal concentration values, ranged from -4.9 to 8.4% using plasma and urine samples. The between-batch precision, given as the relative standard deviation, at three different concentrations (quality control samples) was ranged from -4.7 to 14.0% and from 1.8 to 12.7% in plasma and urine, respectively. The lower limit of quantification and limit of detection of the studied substances were 5.0 and 1.0 nm, respectively. Copyright © 2013 John Wiley & Sons, Ltd.

  10. Analysis of imatinib in bone marrow and plasma samples of chronic myeloid leukaemia patients using solid phase extraction LC-ESI-MS

    OpenAIRE

    Iqbal, Z; Elliott, M; Watson, D.G.; Holyoake, T. L.; Jorgensen, H G

    2011-01-01

    The LC-ESI-MS was developed and validated for the analysis of imatinib in plasma and bone marrow samples using deuterated imatinib (D(8)-IM) as an internal standard. The biological samples were extracted using Strata-X-C SPE cartridges and separated on C8 column (50 x 3 mm, 3 µm), and methanol: 0.1% formic acid (70:30) was delivered at the rate of 0.7 ml/min as a mobile phase. Imatinib was quantified in samples by monitoring the ions m/z 494.3 for imatinib and 502.3 for D8-imatinib on ma...

  11. Variation of plasma parameters in a modified mode of plasma production in a double plasma device

    Indian Academy of Sciences (India)

    A Phukan; M K Mishra; B K Saikia; M Chakraborty

    2010-03-01

    A modified mode of plasma production in a double plasma device is presented and plasma parameters are controlled in this configuration. Here plasma is produced by applying a discharge voltage between the hot filaments in the source (cathode) and the target magnetic cage (anode) of the device. In this configuration, the hot electron emitting filaments are present only in the source and the magnetic cage of this is kept at a negative bias such that due to the repulsion of the cage bias, the primary electrons can go to the grounded target and produce plasma there. The plasma parameters can be controlled by varying the voltages applied to the source magnetic cage and the separation grid of the device.

  12. Plasma volume nomograms for use in therapeutic plasma exchange.

    Science.gov (United States)

    Buffaloe, G W; Heineken, F G

    1983-01-01

    Nomograms have been developed for the convenient estimation of the plasma volumes of patients undergoing therapeutic plasma exchange (TPE), based on equations employing height, body weight, and hematocrit. These nomograms are offered as an aid to prescribing continuous-flow TPE procedure exchange volumes.

  13. KINETIC THEORY OF PLASMA WAVES: Part II: Homogeneous Plasma

    NARCIS (Netherlands)

    Westerhof, E.

    2010-01-01

    The theory of electromagnetic waves in a homogeneous plasma is reviewed. The linear response of the plasma to the waves is obtained in the form of the dielectric tensor. Waves ranging from the low frequency Alfven to the high frequency electron cyclotron waves are discussed in the limit of the cold

  14. Kinetic theory of plasma waves: Part II homogeneous plasma

    NARCIS (Netherlands)

    Westerhof, E.

    2000-01-01

    The theory of electromagnetic waves in a homogeneous plasma is reviewed. The linear response of the plasma to the waves is obtained in the form of the dielectric tensor. Waves ranging from the low frequency Alfven to the high frequency electron cyclotron waves are discussed in the limit of the cold

  15. Kinetic theory of plasma waves - Part II: Homogeneous plasma

    NARCIS (Netherlands)

    Westerhof, E.

    2008-01-01

    The theory of electromagnetic waves in a homogeneous plasma is reviewed. The linear response of the plasma to the waves is obtained in the form of the dielectric tensor. Waves ranging from the low frequency Alfven to the high frequency electron cyclotron waves axe discussed in the limit of the cold

  16. Kinetic theory of plasma waves: Part II homogeneous plasma

    NARCIS (Netherlands)

    Westerhof, E.

    2000-01-01

    The theory of electromagnetic waves in a homogeneous plasma is reviewed. The linear response of the plasma to the waves is obtained in the form of the dielectric tensor. Waves ranging from the low frequency Alfven to the high frequency electron cyclotron waves are discussed in the limit of the cold

  17. KINETIC THEORY OF PLASMA WAVES: Part II: Homogeneous Plasma

    NARCIS (Netherlands)

    Westerhof, E.

    2010-01-01

    The theory of electromagnetic waves in a homogeneous plasma is reviewed. The linear response of the plasma to the waves is obtained in the form of the dielectric tensor. Waves ranging from the low frequency Alfven to the high frequency electron cyclotron waves are discussed in the limit of the cold

  18. Kinetic theory of plasma waves - Part II: Homogeneous plasma

    NARCIS (Netherlands)

    Westerhof, E.

    2008-01-01

    The theory of electromagnetic waves in a homogeneous plasma is reviewed. The linear response of the plasma to the waves is obtained in the form of the dielectric tensor. Waves ranging from the low frequency Alfven to the high frequency electron cyclotron waves axe discussed in the limit of the cold

  19. Plasma probe characteristics in low density hydrogen pulsed plasmas

    CERN Document Server

    Astakhov, D I; Lee, C J; Ivanov, V V; Krivtsun, V M; Zotovich, A I; Zyryanov, S M; Lopaev, D V; Bijkerk, F

    2014-01-01

    Probe theories are only applicable in the regime where the probe's perturbation of the plasma can be neglected. However, it is not always possible to know, a priori, that a particular probe theory can be successfully applied, especially in low density plasmas. This is especially difficult in the case of transient, low density plasmas. Here, we applied probe diagnostics in combination with a 2D particle-in-cell model, to an experiment with a pulsed low density hydrogen plasma. The calculations took into account the full chamber geometry, including the plasma probe as an electrode in the chamber. It was found that the simulations reproduce the time evolution of the probe IV characteristics with good accuracy. The disagreement between the simulated and probe measured plasma density is attributed to the limited applicability of probe theory to measurements of low density pulsed plasmas. Indeed, in the case studied here, probe measurements would lead to a large overestimate of the plasma density. In contrast, the ...

  20. A novel and cost effective method of removing excess albumin from plasma/serum samples and its impacts on LC-MS/MS bioanalysis of therapeutic proteins.

    Science.gov (United States)

    Liu, Guowen; Zhao, Yue; Angeles, Aida; Hamuro, Lora L; Arnold, Mark E; Shen, Jim X

    2014-08-19

    We have developed an innovative method to remove albumin from plasma/serum samples for the LC-MS/MS quantitation of therapeutic proteins. Different combinations of organic solvents and acids were screened for their ability to remove albumin from plasma and serum samples. Removal efficiency was monitored by two signature peptides (QTALVELVK and LVNEVTEFAK) from albumin. Isopropanol with 1.0% trichloroacetic acid was found to be the most effective combination to remove albumin while retaining the protein of interest. Our approach was compared with a commercial albumin depletion kit on both efficiency of albumin removal and recovery of target proteins. We have demonstrated that our approach can remove 95% of the total albumin in human plasma samples while retaining close to 100% for two of three therapeutic proteins tested, with the third one at 60-80%. The commercial kit removed 98% of albumin but suffered at least 50% recovery loss for all therapeutic proteins when compared to our approach. Using BMS-C as a probe compound, the incorporation of the albumin removal approach has improved both assay sensitivity and ruggedness, compared to the whole plasma protein digestion approach alone. An LC-MS/MS method was developed and validated based on this new approach for the analysis of BMS-C in monkey serum. This assay was successfully applied to a toxicological study. When the albumin removal method was used in another clinical LC-MS/MS method, the sensitivity improved 10-fold to 50 ng/mL LLOQ comparing to a typical pellet digestion method.

  1. Reliable LC-MS/MS assay for the estimation of rilpivirine in human plasma: application to a bioequivalence study and incurred sample reanalysis.

    Science.gov (United States)

    Gupta, Ajay; Guttikar, Swati; Patel, Yogesh; Shrivastav, Pranav S; Sanyal, Mallika

    2015-04-01

    A simple, precise, and rapid stable isotope dilution liquid chromatography-tandem mass spectrometry method has been developed and validated for the quantification of rilpivirine, a non-nucleoside reverse transcriptase inhibitor in human plasma. Rilpivirine and its deuterated analogue, rilpivirine-d6, used as an internal standard (IS) were quantitatively extracted by liquid-liquid extraction with methyl-tert-butyl ether and diethyl ether solvent mixture from 50 μL plasma. The chromatography was achieved on Gemini C18 (150 × 4.6 mm, 5 µm) analytical column in a run time of 2.2 min. The precursor → product ion transitions for rilpivirine (m/z 367.1 → 128.0) and IS (m/z 373.2 → 134.2) were monitored on a triple quadrupole mass spectrometer in the positive ionization mode. The linearity of the method was established in the concentration range of 0.5-200 ng/mL. The mean extraction recovery for rilpivirine (94.9%) and IS (99.9%) from spiked plasma samples was consistent and reproducible. The IS-normalized matrix factors for rilpivirine ranged from 0.98 to 1.02 across three quality controls. Bench top, freeze-thaw, wet extract, and long-term stability of rilpivirine was examined in spiked plasma samples. The application of the method was demonstrated by a bioequivalence study with 25 mg rilpivirine tablet formulation in 40 healthy subjects. The assay reproducibility was shown by reanalysis of 200 study samples and the % change in the concentration of repeat values from the original values was within ±15%.

  2. On the excess energy of nonequilibrium plasma

    Energy Technology Data Exchange (ETDEWEB)

    Timofeev, A. V. [National Research Centre Kurchatov Institute, Institute of Hydrogen Power Engineering and Plasma Technologies (Russian Federation)

    2012-01-15

    The energy that can be released in plasma due to the onset of instability (the excess plasma energy) is estimated. Three potentially unstable plasma states are considered, namely, plasma with an anisotropic Maxwellian velocity distribution of plasma particles, plasma with a two-beam velocity distribution, and an inhomogeneous plasma in a magnetic field with a local Maxwellian velocity distribution. The excess energy can serve as a measure of the degree to which plasma is nonequilibrium. In particular, this quantity can be used to compare plasmas in different nonequilibrium states.

  3. Plasma treatment of crane rails

    Directory of Open Access Journals (Sweden)

    Владислав Олександрович Мазур

    2016-07-01

    Full Text Available Crane operation results in wear and tear of rails and crane wheels. Renovation and efficiency of these details is therefore relevant. Modern technologies of wheels and rails restoration use surfacing or high-frequency currents treatment. Surface treatment with highly concentrated streams of energy- with a laser beam, plasma jet- is a promising direction.. It is proposed to increase the efficiency of crane rails by means of surface plasma treatment. The modes of treatment have been chosen.. Modelling of plasma jet thermal impact on a solid body of complex shape has been made. Plasma hardening regimes that meet the requirements of production have been defined. Structural transformation of the material in the crane rails on plasma treatment has been investigated. It has been concluded that for carbon and low alloy crane steels the plasma exposure zone is characterized by a high degree of hardened structure dispersion and higher hardness as compared to the hardness after high-frequency quenching. As this takes place phase transformations are both shift (in the upper zone of plasma influence and fluctuation (in the lower zone of the plasma. With high-speed plasma heating granular or lamellar pearlite mainly transforms into austenite. The level of service characteristics of hardened steel, which is achieved in this case is determined by the kinetics and completeness of pearlite → austenite transformation. For carbon and low alloy rail steels plasma hardening can replace bulk hardening, hardening by high-frequency currents, or surfacing. The modes for plasma treatment which make it possible to obtain a surface layer with a certain service characteristics have been defined

  4. High-beta plasma blobs in the morningside plasma sheet

    Directory of Open Access Journals (Sweden)

    G. Haerendel

    Full Text Available Equator-S frequently encountered, i.e. on 30% of the orbits between 1 March and 17 April 1998, strong variations of the magnetic field strength of typically 5–15-min duration outside about 9RE during the late-night/early-morning hours. Very high-plasma beta values were found, varying between 1 and 10 or more. Close conjunctions between Equator-S and Geotail revealed the spatial structure of these "plasma blobs" and their lifetime. They are typically 5–10° wide in longitude and have an antisymmetric plasma or magnetic pressure distribution with respect to the equator, while being altogether low-latitude phenomena 
    (≤ 15°. They drift slowly sunward, exchange plasma across the equator and have a lifetime of at least 15–30 min. While their spatial structure may be due to some sort of mirror instability, little is known about the origin of the high-beta plasma. It is speculated that the morningside boundary layer somewhat further tailward may be the source of this plasma. This would be consistent with the preference of the plasma blobs to occur during quiet conditions, although they are also found during substorm periods. The relation to auroral phenomena in the morningside oval is uncertain. The energy deposition may be mostly too weak to generate a visible signature. However, patchy aurora remains a candidate for more disturbed periods.

    Key words. Magnetospheric physics (plasma convection; plasma sheet; plasma waves and instabilities

  5. Accuracy of recommended sampling and assay methods for the determination of plasma-free and urinary fractionated metanephrines in the diagnosis of pheochromocytoma and paraganglioma: a systematic review.

    Science.gov (United States)

    Därr, Roland; Kuhn, Matthias; Bode, Christoph; Bornstein, Stefan R; Pacak, Karel; Lenders, Jacques W M; Eisenhofer, Graeme

    2017-06-01

    To determine the accuracy of biochemical tests for the diagnosis of pheochromocytoma and paraganglioma. A search of the PubMed database was conducted for English-language articles published between October 1958 and December 2016 on the biochemical diagnosis of pheochromocytoma and paraganglioma using immunoassay methods or high-performance liquid chromatography with coulometric/electrochemical or tandem mass spectrometric detection for measurement of fractionated metanephrines in 24-h urine collections or plasma-free metanephrines obtained under seated or supine blood sampling conditions. Application of the Standards for Reporting of Diagnostic Studies Accuracy Group criteria yielded 23 suitable articles. Summary receiver operating characteristic analysis revealed sensitivities/specificities of 94/93% and 91/93% for measurement of plasma-free metanephrines and urinary fractionated metanephrines using high-performance liquid chromatography or immunoassay methods, respectively. Partial areas under the curve were 0.947 vs. 0.911. Irrespective of the analytical method, sensitivity was significantly higher for supine compared with seated sampling, 95 vs. 89% (p sampling compared with 24-h urine, 95 vs. 90% (p sampling, seated sampling, and urine. Test accuracy increased linearly from 90 to 93% for 24-h urine at prevalence rates of 0.0-1.0, decreased linearly from 94 to 89% for seated sampling and was constant at 95% for supine conditions. Current tests for the biochemical diagnosis of pheochromocytoma and paraganglioma show excellent diagnostic accuracy. Supine sampling conditions and measurement of plasma-free metanephrines using high-performance liquid chromatography with coulometric/electrochemical or tandem mass spectrometric detection provides the highest accuracy at all prevalence rates.

  6. Comparison of three methods for detecting epidermal growth factor receptor mutations in plasma DNA samples of Chinese patients with advanced non-small cell lung cancer

    Institute of Scientific and Technical Information of China (English)

    QIN Ling; ZHONG Wei; ZHANG Li; LI Long-yun; WANG Meng-zhao

    2011-01-01

    Background Epidermal growth factor receptor (EGFR) mutations can predict tumor response to tyrosine kinase inhibitors (TKIs). Detecting EGFR mutations in plasma DNA samples in patients with advanced non-small cell lung cancer is challenging and promising. We compared three methods for detecting plasma EGFR mutations, including direct DNA sequencing, denaturing high-performance liquid chromatography (DHPLC) and Scorpions Amplification Refractory Mutation System (Scorpions ARMS).Methods Plasma DNA samples from 73 patients with stage ⅢB to Ⅳ adenocarcinoma were analyzed for EGFR mutations in exons 19 (deletion mutation) and 21(L858R mutation) using direct DNA sequencing, DHPLC and Scorpions ARMS. Sensitivities of the three methods were compared and the relationship between EGFR mutations and patients'survival was analyzed.Results In 73 patients, we detected EGFR mutations in 5 samples (6.9%) by direct DNA sequencing, in 22 samples (30.1%) by DHPLC, and in 28 samples (38.4%) by Scorpions ARMS. EGFR mutations were found in 13 samples in exon 19 and in 9 samples in exon 21 by DHPLC, while we found mutations in 15 samples in exon 19 and in 13 samples in exon 21 by Scorpions ARMS. Among the 73 patients, there was 90.4% concordance between DHPLC and Scorpions ARMS (66/73, K=0.79, P=0.07). Of the 73 patients, 46 patients were treated with gefitinib, including 18 patients with mutations and 28 patients without mutations as determined by Scorpions ARMS. The 18 patients with mutations had a significantly longer progression-free survival (PFS) time (median PFS was 21.0 months) than the 28 patients without mutations (median PFS was 7.0 months) (P=0.022).Conclusions Among the three methods for detecting EGFR mutations in plasma DNA samples of patients with advanced lung adenocarcinoma, direct gene sequencing had the lowest sensitivity, while Scorpion ARMS showed the highest mutation detecting capability. DHPLC is slightly less sensitive than Scorpion ARMS. EGFR

  7. Plasma total antioxidant capacity is associated with dietary intake and plasma level of antioxidants in postmenopausal women.

    Science.gov (United States)

    Wang, Ying; Yang, Meng; Lee, Sang-Gil; Davis, Catherine G; Kenny, Anne; Koo, Sung I; Chun, Ock K

    2012-12-01

    Increased plasma total antioxidant capacity (TAC) has been associated with a high consumption of fruits and vegetables. However, limited information is available on whether plasma TAC reflects the dietary intake of antioxidants and the levels of individual antioxidants in plasma. By using three different assays, the study aimed to determine if plasma TAC can effectively predict dietary intake of antioxidants and plasma antioxidant status. Forty overweight and apparently healthy postmenopausal women were recruited. Seven-day food records and 12-h fasting blood samples were collected for dietary and plasma antioxidant assessments. Plasma TAC was determined by vitamin C equivalent antioxidant capacity (VCEAC), ferric-reducing ability of plasma (FRAP) and oxygen radical absorbance capacity (ORAC) assays. TAC values determined by VCEAC were highly correlated with FRAP (r=0.79, Pantioxidants and represents more closely the plasma antioxidant levels than ORAC and FRAP.

  8. MHD control in burning plasmas MHD control in burning plasmas

    Science.gov (United States)

    Donné, Tony; Liang, Yunfeng

    2012-07-01

    Fusion physics focuses on the complex behaviour of hot plasmas confined by magnetic fields with the ultimate aim to develop a fusion power plant. In the future generation of tokamaks like ITER, the power generated by the fusion reactions substantially exceeds the external input power (Pfusion}/Pin >= 10). When this occurs one speaks of a burning plasma. Twenty per cent of the generated fusion power in a burning plasma is carried by the charged alpha particles, which transfer their energy to the ambient plasma in collisions, a process called thermalization. A new phenomenon in burning plasmas is that the alpha particles, which form a minority but carry a large fraction of the plasma kinetic energy, can collectively drive certain types of magneto-hydrodynamic (MHD) modes, while they can suppress other MHD modes. Both types of MHD modes can have desirable effects on the plasma, as well as be detrimental to the plasma. For example, the so-called sawtooth instability, on the one hand, is largely responsible for the transport of the thermalized alpha particles out of the core, but, on the other hand, may result in the loss of the energetic alphas before they have fully thermalized. A further undesirable effect of the sawtooth instability is that it may trigger other MHD modes such as neoclassical tearing modes (NTMs). These NTMs, in turn, are detrimental to the plasma confinement and in some cases may even lead to disruptive termination of the plasma. At the edge of the plasma, finally, so-called edge localized modes or ELMs occur, which result in extremely high transient heat and particle loads on the plasma-facing components of a reactor. In order to balance the desired and detrimental effects of these modes, active feedback control is required. An additional complication occurs in a burning plasma as the external heating power, which is nowadays generally used for plasma control, is small compared to the heating power of the alpha particles. The scientific challenge

  9. Research in plasma physics

    Science.gov (United States)

    1973-01-01

    Three aspects of barium ion cloud dynamics are discussed. First, the effect of the ratio of ion cloud conductivity to background ionospheric conductivity on the motion of barium ion clouds is investigated and compared with observations of barium ion clouds. This study led to the suggestion that the conjugate ionosphere participates in the dynamics of barium ion clouds. Second, analytic work on the deformation of ion clouds is presented. Third, a linearized stability theory was extended to include the effect of the finite extent of an ion cloud, as well as the effect of the ratio of ion cloud to ionospheric conductivities. The stability properties of a plasma with contra-streaming ion beams parallel to a magnetic field are investigated. The results are interpreted in terms of parameters appropriate for collisionless shock waves. It is found that this particular instability can be operative only if the up-stream Alfven Mach number exceeds 5.5.

  10. COSMIC PLASMA DYNAMO

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    A new dynamo model based on the polarization of plasma is presented in this paper.From the Maxwell equations in a moving medium, a magnetization vector can be causedwith Rongon current. The steady solar magnetic field is solved from the equations. Onthe assumption that the meridianal flow is ignored, the distribution of magnetic field isput out. In the model, there is no additional parameter considered. The intensity ofmagnetic field inside the sun ranges from 1-6T. The surface magnetic field around thepole is in the order of 1×10-3T, at low latitude the calculated surface magnetic fieldhas the order of 1×10-2 T. The maximum magnetic field is around 30° in latitude.

  11. Optimization of plasma amplifiers

    Science.gov (United States)

    Sadler, James D.; Trines, Raoul M. Â. G. Â. M.; Tabak, Max; Haberberger, Dan; Froula, Dustin H.; Davies, Andrew S.; Bucht, Sara; Silva, Luís O.; Alves, E. Paulo; Fiúza, Frederico; Ceurvorst, Luke; Ratan, Naren; Kasim, Muhammad F.; Bingham, Robert; Norreys, Peter A.

    2017-05-01

    Plasma amplifiers offer a route to side-step limitations on chirped pulse amplification and generate laser pulses at the power frontier. They compress long pulses by transferring energy to a shorter pulse via the Raman or Brillouin instabilities. We present an extensive kinetic numerical study of the three-dimensional parameter space for the Raman case. Further particle-in-cell simulations find the optimal seed pulse parameters for experimentally relevant constraints. The high-efficiency self-similar behavior is observed only for seeds shorter than the linear Raman growth time. A test case similar to an upcoming experiment at the Laboratory for Laser Energetics is found to maintain good transverse coherence and high-energy efficiency. Effective compression of a 10 kJ , nanosecond-long driver pulse is also demonstrated in a 15-cm-long amplifier.

  12. Turbulent transport in magnetized plasmas

    CERN Document Server

    Horton, Wendell

    2012-01-01

    This book explains how magnetized plasmas self-organize in states of electromagnetic turbulence that transports particles and energy out of the core plasma faster than anticipated by the fusion scientists designing magnetic confinement systems in the 20th century. It describes theory, experiments and simulations in a unified and up-to-date presentation of the issues of achieving nuclear fusion power.

  13. Plasma chemistry and organic synthesis

    Science.gov (United States)

    Tezuka, M.

    1980-01-01

    The characteristic features of chemical reactions using low temperature plasmas are described and differentiated from those seen in other reaction systems. A number of examples of applications of plasma chemistry to synthetic reactions are mentioned. The production of amino acids by discharge reactions in hydrocarbon-ammonia-water systems is discussed, and its implications for the origins of life are mentioned.

  14. Waves and instabilities in plasmas

    CERN Document Server

    Chen Liu

    1987-01-01

    The topics covered in these notes are selective and tend to emphasize more on kinetic-theory approaches to waves and instabilities in both uniform and non-uniform plasmas, students are assumed to have some basic knowledge of plasma dynamics in terms of single-particle and fluid descriptions.

  15. Continuous supersonic plasma wind tunnel

    DEFF Research Database (Denmark)

    Andersen, S.A.; Jensen, Vagn Orla; Nielsen, P.

    1968-01-01

    The B field configuration of a Q-device has been modified into a magnetic Laval nozzle. Continuous supersonic plasma flow is observed with M≈3......The B field configuration of a Q-device has been modified into a magnetic Laval nozzle. Continuous supersonic plasma flow is observed with M≈3...

  16. Continuous supersonic plasma wind tunnel

    DEFF Research Database (Denmark)

    Andersen, S.A.; Jensen, Vagn Orla; Nielsen, P.

    1969-01-01

    The normal magnetic field configuration of a Q device has been modified to obtain a 'magnetic Laval nozzle'. Continuous supersonic plasma 'winds' are obtained with Mach numbers ~3. The magnetic nozzle appears well suited for the study of the interaction of supersonic plasma 'winds' with either...

  17. Plasma generation induced by triboelectrification

    DEFF Research Database (Denmark)

    Kusano, Yukihiro; Singh, Shailendra Vikram; Michelsen, Poul

    2009-01-01

    A gas discharge plasma can be induced by triboelectrification around a sliding contact. The detailed physical mechanism of triboelectrification is unknown, but an empirical classification scheme can be referred to in practice. It is reported that intense ultra-violet emission from a plasma...

  18. Supersonic induction plasma jet modeling

    Energy Technology Data Exchange (ETDEWEB)

    Selezneva, S.E. E-mail: svetlana2@hermes.usherbS_Selezneva2@hermes.usherb; Boulos, M.I

    2001-06-01

    Numerical simulations have been applied to study the argon plasma flow downstream of the induction plasma torch. It is shown that by means of the convergent-divergent nozzle adjustment and chamber pressure reduction, a supersonic plasma jet can be obtained. We investigate the supersonic and a more traditional subsonic plasma jets impinging onto a normal substrate. Comparing to the subsonic jet, the supersonic one is narrower and much faster. Near-substrate velocity and temperature boundary layers are thinner, so the heat flux near the stagnation point is higher in the supersonic jet. The supersonic plasma jet is characterized by the electron overpopulation and the domination of the recombination over the dissociation, resulting into the heating of the electron gas. Because of these processes, the supersonic induction plasma permits to separate spatially different functions (dissociation and ionization, transport and deposition) and to optimize each of them. The considered configuration can be advantageous in some industrial applications, such as plasma-assisted chemical vapor deposition of diamond and polymer-like films and in plasma spraying of nanoscaled powders.

  19. Plasma-heating by induction

    Science.gov (United States)

    Harrington, K.; Thorpe, M. L.

    1969-01-01

    Induction-heated plasma torch operates with an input of 1 Mw of direct current of which 71 percent is transferred to the plasma and the remainder is consumed by electrical losses in the system. Continuous operation of the torch should be possible for as long as 5,000 hours.

  20. Spectroscopy of Low Temperature Plasma

    CERN Document Server

    Ochkin, Vladimir N

    2009-01-01

    Providing an up-to-date overview on spectroscopical diagnostics of low temperature plasma Spectroscopy of Low Temperature Plasma covers the latest developments and techniques. Written by a distinguished scientist and experienced book author this text is applicable to many fields in materials and surface science as well as nanotechnology and contains numerous appendices with indispensable reference data.

  1. NCSX Plasma Heating Methods

    Energy Technology Data Exchange (ETDEWEB)

    H.W. Kugel; D. Spong; R. Majeski; M. Zarnstorff

    2003-02-28

    The NCSX (National Compact Stellarator Experiment) has been designed to accommodate a variety of heating systems, including ohmic heating, neutral-beam injection, and radio-frequency. Neutral beams will provide one of the primary heating methods for NCSX. In addition to plasma heating, beams are also expected to provide a means for external control over the level of toroidal plasma rotation velocity and its profile. The plan is to provide 3 MW of 50 keV balanced neutral-beam tangential injection with pulse lengths of 500 msec for initial experiments, and to be upgradeable to pulse lengths of 1.5 sec. Subsequent upgrades will add 3 MW of neutral-beam injection. This Chapter discusses the NCSX neutral-beam injection requirements and design issues, and shows how these are provided by the candidate PBX-M (Princeton Beta Experiment-Modification) neutral-beam injection system. In addition, estimations are given for beam-heating efficiencies, scaling of heating efficiency with machine size an d magnetic field level, parameter studies of the optimum beam-injection tangency radius and toroidal injection location, and loss patterns of beam ions on the vacuum chamber wall to assist placement of wall armor and for minimizing the generation of impurities by the energetic beam ions. Finally, subsequent upgrades could add an additional 6 MW of radio-frequency heating by mode-conversion ion-Bernstein wave (MCIBW) heating, and if desired as possible future upgrades, the design also will accommodate high-harmonic fast-wave and electron-cyclotron heating. The initial MCIBW heating technique and the design of the radio-frequency system lend themselves to current drive, so that if current drive became desirable for any reason only minor modifications to the heating system described here would be needed. The radio-frequency system will also be capable of localized ion heating (bulk or tail), and possibly ion-Bernstein-wave-generated sheared flows.

  2. NCSX Plasma Heating Methods

    Energy Technology Data Exchange (ETDEWEB)

    Kugel, H. W.; Spong, D.; Majeski, R.; Zarnstorff, M.

    2008-01-18

    The National Compact Stellarator Experiment (NCSX) has been designed to accommodate a variety of heating systems, including ohmic heating, neutral beam injection, and radio-frequency (rf). Neutral beams will provide one of the primary heating methods for NCSX. In addition to plasma heating, neutral beams are also expected to provide a means for external control over the level of toroidal plasma rotation velocity and its profile. The experimental plan requires 3 MW of 50-keV balanced neutral beam tangential injection with pulse lengths of 500 ms for initial experiments, to be upgradeable to pulse lengths of 1.5 s. Subsequent upgrades will add 3MW of neutral beam injection (NBI). This paper discusses the NCSX NBI requirements and design issues and shows how these are provided by the candidate PBX-M NBI system. In addition, estimations are given for beam heating efficiencies, scaling of heating efficiency with machine size and magnetic field level, parameter studies of the optimum beam injection tangency radius and toroidal injection location, and loss patterns of beam ions on the vacuum chamber wall to assist placement of wall armor and for minimizing the generation of impurities by the energetic beam ions. Finally, subsequent upgrades could add an additional 6 MW of rf heating by mode conversion ion Bernstein wave (MCIBW) heating, and if desired as possible future upgrades, the design also will accommodate high-harmonic fast-wave and electron cyclotron heating. The initial MCIBW heating technique and the design of the rf system lend themselves to current drive, so if current drive became desirable for any reason, only minor modifications to the heating system described here would be needed. The rf system will also be capable of localized ion heating (bulk or tail), and possiblyIBW-generated sheared flows.

  3. Development and validation of an HPLC-MS/MS method to quantify clopidogrel acyl glucuronide, clopidogrel acid metabolite, and clopidogrel in plasma samples avoiding analyte back-conversion.

    Science.gov (United States)

    Silvestro, Luigi; Gheorghe, Mihaela; Iordachescu, Adriana; Ciuca, Valentin; Tudoroniu, Ariana; Rizea Savu, Simona; Tarcomnicu, Isabela

    2011-08-01

    A new sensitive and fast quantitative analytical method for the simultaneous determination of clopidogrel, its main metabolite clopidogrel carboxylic acid, and the newly described acyl glucuronide metabolite, in human plasma samples, is presented. The analytical procedures (plasma storage, handling, and extract storage in the autosampler) were optimized in order to avoid back-conversion; a known drawback in measurements of clopidogrel. Clopidogrel acyl glucuronide was confirmed as a major source of back-conversion to the parent drug in the presence of methanol, and thorough stability experiments were carried out to find the most appropriate conditions for an accurate analysis of clopidogrel and the two metabolites. The method was validated by assessing selectivity, sensitivity, linearity, accuracy, and precision for all three analytes, in accordance to Food and Drug Administration guidelines. Spiked quality controls in plasma as well as incurred samples were used to verify back-conversion in the selected conditions, with results meeting European Medicines Agency acceptance criteria (concentrations within 80-120% of the first reading). The method was then applied to a pharmacokinetic study, and for the first time, a pharmacokinetic curve of clopidogrel acyl glucuronide in human plasma is presented. The concentrations ranged up to 1,048.684 ng/mL, with a mean of 470.268 ng/mL, while clopidogrel had a mean C(max) of 1.348 ng/mL; these orders of magnitude show how much the back-conversion of this metabolite may influence clopidogrel quantification if it is not properly controlled.

  4. Cell Adhesion to Plasma-Coated PVC

    OpenAIRE

    Elidiane C. Rangel; Souza,Eduardo S. de; Francine S. de Moraes; Eliana A. R. Duek; Carolina Lucchesi; Schreiner, Wido H.; Durrant, Steven F.; Cruz, Nilson C.

    2014-01-01

    To produce environments suitable for cell culture, thin polymer films were deposited onto commercial PVC plates from radiofrequency acetylene-argon plasmas. The proportion of argon in the plasmas, P-Ar, was varied from 5.3 to 65.8%. The adhesion and growth of Vero cells on the coated surfaces were examined for different incubation times. Cytotoxicity tests were performed using spectroscopic methods. Carbon, O, and N were detected in all the samples using XPS. Roughness remained almost unchang...

  5. Coherent structures in two-dimensional plasma turbulence

    DEFF Research Database (Denmark)

    Huld, T.; Nielsen, A.H.; Pécseli, H.L.;

    1991-01-01

    -band turbulent fluctuations is demonstrated by a conditional sampling technique. Depending on plasma parameters, the dominant structures can appear as monopole or multipole vortices, dipole vortices in particular. The importance of large structures for the turbulent plasma diffusion is discussed. A statistical...... analysis of the randomly varying plasma flux is presented....

  6. Intermittent transport in edge plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, O.E.; Naulin, V.; Nielsen, A.H.; Juul Rasmussen, J. [Association EURATOM-Riso National Laboratory, Optics and Plasma Research, Roskilde (Denmark)

    2004-07-01

    The properties of low-frequency convective fluctuations and transport are investigated for the boundary region of magnetized plasmas. We employ a two-dimensional fluid model for the evolution of the global plasma quantities in a geometry and with parameters relevant to the scrape-off layer of confined toroidal plasmas. Strongly intermittent plasma transport is regulated by self-consistently generated sheared poloidal flows and is mediated by burst ejection of particles and heat from the bulk plasma in the form of blobs. Coarse grained probe signals reveal a highly skewed and flat distribution on short time scales, but tends towards a normal distribution at large time scales. Conditionally averaged signals are in perfect agreement with experimental measurements. (authors)

  7. Helicon plasma thruster discharge model

    Energy Technology Data Exchange (ETDEWEB)

    Lafleur, T., E-mail: trevor.lafleur@lpp.polytechnique.fr [Laboratoire de Physique des Plasmas, CNRS, Sorbonne Universités, UPMC Univ Paris 06, Univ Paris-Sud, Ecole Polytechnique, 91128 Palaiseau, France and ONERA - The French Aerospace Lab, 91120 Palaiseau (France)

    2014-04-15

    By considering particle, momentum, and energy balance equations, we develop a semi-empirical quasi one-dimensional analytical discharge model of radio-frequency and helicon plasma thrusters. The model, which includes both the upstream plasma source region as well as the downstream diverging magnetic nozzle region, is compared with experimental measurements and confirms current performance levels. Analysis of the discharge model identifies plasma power losses on the radial and back wall of the thruster as the major performance reduction factors. These losses serve as sinks for the input power which do not contribute to the thrust, and which reduce the maximum plasma density and hence propellant utilization. With significant radial plasma losses eliminated, the discharge model (with argon) predicts specific impulses in excess of 3000 s, propellant utilizations above 90%, and thruster efficiencies of about 30%.

  8. A Multibunch Plasma Wakefield Accelerator

    CERN Document Server

    Kallos, Efthymios; Ben-Zvi, Ilan; Katsouleas, Thomas C; Kimura, Wayne D; Kusche, Karl; Muggli, Patric; Pavlishin, Igor; Pogorelsky, Igor; Yakimenko, Vitaly; Zhou, Feng

    2005-01-01

    We investigate a plasma wakefield acceleration scheme where a train of electron microbunches feeds into a high density plasma. When the microbunch train enters such a plasma that has a corresponding plasma wavelength equal to the microbunch separation distance, a strong wakefield is expected to be resonantly driven to an amplitude that is at least one order of magnitude higher than that using an unbunched beam. PIC simulations have been performed using the beamline parameters of the Brookhaven National Laboratory Accelerator Test Facility operating in the configuration of the STELLA inverse free electron laser (IFEL) experiment. A 65 MeV electron beam is modulated by a 10.6 um CO2 laser beam via an IFEL interaction. This produces a train of ~90 microbunches separated by the laser wavelength. In this paper, we present both a simple theoretical treatment and simulation results that demonstrate promising results for the multibunch technique as a plasma-based accelerator.

  9. Plasma treatment advantages for textiles

    CERN Document Server

    Sparavigna, Amelia

    2008-01-01

    The textile industry is searching for innovative production techniques to improve the product quality, as well as society requires new finishing techniques working in environmental respect. Plasma surface treatments show distinct advantages, because they are able to modify the surface properties of inert materials, sometimes with environment friendly devices. For fabrics, cold plasma treatments require the development of reliable and large systems. Such systems are now existing and the use of plasma physics in industrial problems is rapidly increasing. On textile surfaces, three main effects can be obtained depending on the treatment conditions: the cleaning effect, the increase of microroughness (anti-pilling finishing of wool) and the production of radicals to obtain hydrophilic surfaces. Plasma polymerisation, that is the deposition of solid polymeric materials with desired properties on textile substrates, is under development. The advantage of such plasma treatments is that the modification turns out to ...

  10. Simultaneous extraction and quantification of lamotrigine, phenobarbital, and phenytoin in human plasma and urine samples using solidified floating organic drop microextraction and high-performance liquid chromatography.

    Science.gov (United States)

    Asadi, Mohammad; Dadfarnia, Shayessteh; Haji Shabani, Ali Mohammad; Abbasi, Bijan

    2015-07-01

    A novel and simple method based on solidified floating organic drop microextraction followed by high-performance liquid chromatography with ultraviolet detection has been developed for simultaneous preconcentration and determination of phenobarbital, lamotrigine, and phenytoin in human plasma and urine samples. Factors affecting microextraction efficiency such as the type and volume of the extraction solvent, sample pH, extraction time, stirring rate, extraction temperature, ionic strength, and sample volume were optimized. Under the optimum conditions (i.e. extraction solvent, 1-undecanol (40 μL); sample pH, 8.0; temperature, 25°C; stirring rate, 500 rpm; sample volume, 7 mL; potassium chloride concentration, 5% and extraction time, 50 min), the limits of detection for phenobarbital, lamotrigine, and phenytoin were 1.0, 0.1, and 0.3 μg/L, respectively. Also, the calibration curves for phenobarbital, lamotrigine, and phenytoin were linear in the concentration range of 2.0-300.0, 0.3-200.0, and 1.0-200.0 μg/L, respectively. The relative standard deviations for six replicate extractions and determinations of phenobarbital, lamotrigine, and phenytoin at 50 μg/L level were less than 4.6%. The method was successfully applied to determine phenobarbital, lamotrigine, and phenytoin in plasma and urine samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Aerospace applications of pulsed plasmas

    Science.gov (United States)

    Starikovskiy, Andrey

    2012-10-01

    The use of a thermal equilibrium plasma for combustion control dates back more than a hundred years to the advent of internal combustion (IC) engines and spark ignition systems. The same principles are still applied today to achieve high efficiency in various applications. Recently, the potential use of nonequilibrium plasma for ignition and combustion control has garnered increasing interest due to the possibility of plasma-assisted approaches for ignition and flame stabilization. During the past decade, significant progress has been made toward understanding the mechanisms of plasma chemistry interactions, energy redistribution and the nonequilibrium initiation of combustion. In addition, a wide variety of fuels have been examined using various types of discharge plasmas. Plasma application has been shown to provide additional combustion control, which is necessary for ultra-lean flames, high-speed flows, cold low-pressure conditions of high-altitude gas turbine engine (GTE) relight, detonation initiation in pulsed detonation engines (PDE) and distributed ignition control in homogeneous charge-compression ignition (HCCI) engines, among others. The present paper describes the current understanding of the nonequilibrium excitation of combustible mixtures by electrical discharges and plasma-assisted ignition and combustion. Nonequilibrium plasma demonstrates an ability to control ultra-lean, ultra-fast, low-temperature flames and appears to be an extremely promising technology for a wide range of applications, including aviation GTEs, piston engines, ramjets, scramjets and detonation initiation for pulsed detonation engines. To use nonequilibrium plasma for ignition and combustion in real energetic systems, one must understand the mechanisms of plasma-assisted ignition and combustion and be able to numerically simulate the discharge and combustion processes under various conditions.

  12. The 2017 Plasma Roadmap: Low temperature plasma science and technology

    Science.gov (United States)

    Adamovich, I.; Baalrud, S. D.; Bogaerts, A.; Bruggeman, P. J.; Cappelli, M.; Colombo, V.; Czarnetzki, U.; Ebert, U.; Eden, J. G.; Favia, P.; Graves, D. B.; Hamaguchi, S.; Hieftje, G.; Hori, M.; Kaganovich, I. D.; Kortshagen, U.; Kushner, M. J.; Mason, N. J.; Mazouffre, S.; Mededovic Thagard, S.; Metelmann, H.-R.; Mizuno, A.; Moreau, E.; Murphy, A. B.; Niemira, B. A.; Oehrlein, G. S.; Petrovic, Z. Lj; Pitchford, L. C.; Pu, Y.-K.; Rauf, S.; Sakai, O.; Samukawa, S.; Starikovskaia, S.; Tennyson, J.; Terashima, K.; Turner, M. M.; van de Sanden, M. C. M.; Vardelle, A.

    2017-08-01

    Journal of Physics D: Applied Physics published the first Plasma Roadmap in 2012 consisting of the individual perspectives of 16 leading experts in the various sub-fields of low temperature plasma science and technology. The 2017 Plasma Roadmap is the first update of a planned series of periodic updates of the Plasma Roadmap. The continuously growing interdisciplinary nature of the low temperature plasma field and its equally broad range of applications are making it increasingly difficult to identify major challenges that encompass all of the many sub-fields and applications. This intellectual diversity is ultimately a strength of the field. The current state of the art for the 19 sub-fields addressed in this roadmap demonstrates the enviable track record of the low temperature plasma field in the development of plasmas as an enabling technology for a vast range of technologies that underpin our modern society. At the same time, the many important scientific and technological challenges shared in this roadmap show that the path forward is not only scientifically rich but has the potential to make wide and far reaching contributions to many societal challenges.

  13. Meter scale plasma source for plasma wakefield experiments

    Science.gov (United States)

    Vafaei-Najafabadi, N.; Shaw, J. L.; Marsh, K. A.; Joshi, C.; Hogan, M. J.

    2012-12-01

    High accelerating gradients generated by a high density electron beam moving through plasma has been used to double the energy of the SLAC electron beam [1]. During that experiment, the electron current density was high enough to generate its own plasma without significant head erosion. In the newly commissioned FACET facility at SLAC, the peak current will be lower and without pre-ionization, head erosion will be a significant challenge for the planned experiments. In this work we report on our design of a meter scale plasma source for these experiments to effectively avoid the problem of head erosion. The plasma source is based on a homogeneous metal vapor gas column that is generated in a heat pipe oven [2]. A lithium oven over 30 cm long at densities over 1017 cm-3 has been constructed and tested at UCLA. The plasma is then generated by coupling a 10 TW short pulse Ti:Sapphire laser into the gas column using an axicon lens setup. The Bessel profile of the axicon setup creates a region of high intensity that can stretch over the full length of the gas column with approximately constant diameter. In this region of high intensity, the alkali metal vapor is ionized through multi-photon ionization process. In this manner, a fully ionized meter scale plasma of uniform density can be formed. Methods for controlling the plasma diameter and length will also be discussed.

  14. Meter scale plasma source for plasma wakefield experiments

    Energy Technology Data Exchange (ETDEWEB)

    Vafaei-Najafabadi, N.; Shaw, J. L.; Marsh, K. A.; Joshi, C.; Hogan, M. J. [Department of Electrical Engineering, University of California Los Angeles, Los Angeles, CA 90095 (United States); SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States)

    2012-12-21

    High accelerating gradients generated by a high density electron beam moving through plasma has been used to double the energy of the SLAC electron beam [1]. During that experiment, the electron current density was high enough to generate its own plasma without significant head erosion. In the newly commissioned FACET facility at SLAC, the peak current will be lower and without pre-ionization, head erosion will be a significant challenge for the planned experiments. In this work we report on our design of a meter scale plasma source for these experiments to effectively avoid the problem of head erosion. The plasma source is based on a homogeneous metal vapor gas column that is generated in a heat pipe oven [2]. A lithium oven over 30 cm long at densities over 10{sup 17} cm{sup -3} has been constructed and tested at UCLA. The plasma is then generated by coupling a 10 TW short pulse Ti:Sapphire laser into the gas column using an axicon lens setup. The Bessel profile of the axicon setup creates a region of high intensity that can stretch over the full length of the gas column with approximately constant diameter. In this region of high intensity, the alkali metal vapor is ionized through multi-photon ionization process. In this manner, a fully ionized meter scale plasma of uniform density can be formed. Methods for controlling the plasma diameter and length will also be discussed.

  15. Revisiting the plasma sheath - dust in plasma sheath

    CERN Document Server

    Das, G C; Bora, M P

    2015-01-01

    In this work, we have considered the formation of warm plasma sheath in the vicinity of a wall in a plasma with considerable presence of dust particles. As an example, we have used the parameters relevant in case of lunar plasma sheath, though the results obtained in this work could be applied to any other physical situation such as laboratory plasma. In the ion-acoustic time scale, we neglect the dust dynamics. The dust particles affect the sheath dynamics by affecting the Poisson equation which determines the plasma potential in the sheath region. We have assumed the current to a dust particle to be balanced throughout the analysis. This makes the grain potential dependent on plasma potential, which is then incorporated into the Poisson equation. The resultant numerical model becomes an initial value problem, which is described by a 1-D integro-differential equation, which is then solved self-consistently by incorporating the change in plasma potential caused by inclusion of the dust potential in the Poisso...

  16. Materials Analysis of Transient Plasma-Wall Interactions

    Science.gov (United States)

    2014-05-13

    model showing the importance sputter and re-deposition. plasma, pulsed plasma, directed energy, transient wall interaction, high energy density...each equipped with a 25kV copper- vapor thyratron start switch capable of sub-microsecond triggering resolution. Each start switch is paired with a...sample exposure positions within the plasma jet. The probe utilizes a PCB Piezotronics model 113B21 pressure sensor modified to work in the plasma jet

  17. The possibilities of atmospheric plasma-spraying application to obtain hydroxyapatite coatings on the stainless steel samples

    Directory of Open Access Journals (Sweden)

    Mihailović Marija D.

    2013-01-01

    Full Text Available For decades, the standard metallic materials for hip implants, besides the 316LVM stainless steel, were titanium- and cobalt/chromium-based alloys. Although bioinert, due to their corrosion resistance, they are not biocompatible. Contemporary surgical implants are not made just of bioinert metal anymore, but with deposited bioactive hydroxyapatite (HAp coating. Hydroxyapatite is chemically identical with the mineral constituent of bones and teeth, what besides its biocompatibility provides bioactivity as well. The HAp limitations are, however, weak tensile strength and low fatigue resistance for long term loadings, if used alone. This is the reason for HAp to be deposited onto the surgical implant, and to enable its bioactivity, what means intergrowth with bones, and therefore the long-lasting and mechanical stable non-cemented prosthesis. This is important predominantly because the need for such prostheses for younger population, and a better life quality. There are several contemporary techniques that have been used for deposition of these coatings onto the metal implant. The possibilities of atmospheric plasma-spraying for obtaining the stable HAp coatings on the 316LVM stainless steel, ordinary used as a standard material for hip implants production are presented in this paper. The coatings of a commercially available hydroxyapatite powder were plasma-sprayed onto the specimens of medical grade 316LVM stainless steel under various operating conditions. The optical microscopy was used for microstructure and porosity characterization, while coating morphology and Ca/P ratio were analyzed using SEM equipped with EDX. Coating microstructure varied from a porous to a glassy structure, depending on operating conditions applied and coating thickness. Coating porosity was determined to be at the lower required limit requested for the bone-coating intergrowth possibility, but nevertheless adhesion measurements showed good results. The Ca/P ratio was

  18. Arc Plasma Gun With Coaxial Powder Feed

    Science.gov (United States)

    Zaplatynsky, Isidor

    1988-01-01

    Redesigned plasma gun provides improved metallic and ceramic coatings. Particles injected directly through coaxial bore in cathode into central region of plasma jet. Introduced into hotter and faster region of plasma jet.

  19. [Plasma technology for biomedical material applications].

    Science.gov (United States)

    Liu, Z; Li, X

    2000-03-01

    In this paper is introduced the plasma technology for the applications of several species biomaterial such as ophthalmological material, drug delivery system, tissue culture material, blood anticoagulant material as well as plasma surface clearing and plasma sterilization, and so on.

  20. Atmospheric pressure plasma produced inside a closed package by a dielectric barrier discharge in Ar/CO2 for bacterial inactivation of biological samples

    DEFF Research Database (Denmark)

    Chiper, Alina Silvia; Chen, Weifeng; Mejlholm, Ole

    2011-01-01

    The generation and evaluation of a dielectric barrier discharge produced inside a closed package made of a commercially available packaging film and filled with gas mixtures of Ar/CO2 at atmospheric pressure is reported. The discharge parameters were analysed by electrical measurements and optical...... times higher in the Ar/CO2 plasma compared with an Ar plasma. The efficiency of the produced plasma for the inactivation of bacteria on food inside the closed package was investigated....

  1. Collisionless Coupling between Explosive Debris Plasma and Magnetized Ambient Plasma

    Science.gov (United States)

    Bondarenko, Anton

    2016-10-01

    The explosive expansion of a dense debris plasma cloud into relatively tenuous, magnetized, ambient plasma characterizes a wide variety of astrophysical and space phenomena, including supernova remnants, interplanetary coronal mass ejections, and ionospheric explosions. In these rarified environments, collective electromagnetic processes rather than Coulomb collisions typically mediate the transfer of momentum and energy from the debris plasma to the ambient plasma. In an effort to better understand the detailed physics of collisionless coupling mechanisms in a reproducible laboratory setting, the present research jointly utilizes the Large Plasma Device (LAPD) and the Phoenix laser facility at UCLA to study the super-Alfvénic, quasi-perpendicular expansion of laser-produced carbon (C) and hydrogen (H) debris plasma through preformed, magnetized helium (He) ambient plasma via a variety of diagnostics, including emission spectroscopy, wavelength-filtered imaging, and magnetic field induction probes. Large Doppler shifts detected in a He II ion spectral line directly indicate initial ambient ion acceleration transverse to both the debris plasma flow and the background magnetic field, indicative of a fundamental process known as Larmor coupling. Characterization of the laser-produced debris plasma via a radiation-hydrodynamics code permits an explicit calculation of the laminar electric field in the framework of a ``hybrid'' model (kinetic ions, charge-neutralizing massless fluid electrons), thus allowing for a simulation of the initial response of a distribution of He II test ions. A synthetic Doppler-shifted spectrum constructed from the simulated velocity distribution of the accelerated test ions excellently reproduces the spectroscopic measurements, confirming the role of Larmor coupling in the debris-ambient interaction.

  2. Age-specific discrimination of blood plasma samples of healthy and ovarian cancer prone mice using laser-induced breakdown spectroscopy

    Science.gov (United States)

    Melikechi, Noureddine; Markushin, Yuri; Connolly, Denise C.; Lasue, Jeremie; Ewusi-Annan, Ebo; Makrogiannis, Sokratis

    2016-09-01

    Epithelial ovarian cancer (EOC) mortality rates are strongly correlated with the stage at which it is diagnosed. Detection of EOC prior to its dissemination from the site of origin is known to significantly improve the patient outcome. However, there are currently no effective methods for early detection of the most common and lethal subtype of EOC. We sought to determine whether laser-induced breakdown spectroscopy (LIBS) and classification techniques such as linear discriminant analysis (LDA) and random forest (RF) could classify and differentiate blood plasma specimens from transgenic mice with ovarian carcinoma and wild type control mice. Herein we report results using this approach to distinguish blood plasma samples obtained from serially bled (at 8, 12, and 16 weeks) tumor-bearing TgMISIIR-TAg transgenic and wild type cancer-free littermate control mice. We have calculated the age-specific accuracy of classification using 18,000 laser-induced breakdown spectra of the blood plasma samples from tumor-bearing mice and wild type controls. When the analysis is performed in the spectral range 250 nm to 680 nm using LDA, these are 76.7 (± 2.6)%, 71.2 (± 1.3)%, and 73.1 (± 1.4)%, for the 8, 12 and 16 weeks. When the RF classifier is used, we obtain values of 78.5 (± 2.3)%, 76.9 (± 2.1)% and 75.4 (± 2.0)% in the spectral range of 250 nm to 680 nm, and 81.0 (± 1.8)%, 80.4 (± 2.1)% and 79.6 (± 3.5)% in 220 nm to 850 nm. In addition, we report, the positive and negative predictive values of the classification of the two classes of blood plasma samples. The approach used in this study is rapid, requires only 5 μL of blood plasma, and is based on the use of unsupervised and widely accepted multivariate analysis algorithms. These findings suggest that LIBS and multivariate analysis may be a novel approach for detecting EOC.

  3. Experimental investigation of plasma relaxation using a compact coaxial magnetized plasma gun in a background plasma

    Science.gov (United States)

    Zhang, Yue; Lynn, Alan; Gilmore, Mark; Hsu, Scott; University of New Mexico Collaboration; Los Alamos National Laboratory Collaboration

    2013-10-01

    A compact coaxial plasma gun is employed for experimental studies of plasma relaxation in a low density background plasma. Experiments are being conducted in the linear HelCat device at UNM. These studies will advance the knowledge of basic plasma physics in the areas of magnetic relaxation and space and astrophysical plasmas, including the evolution of active galactic jets/radio lobes within the intergalactic medium. The gun is powered by a 120pF ignitron-switched capacitor bank which is operated in a range of 5-10 kV and ~100 kA. Multiple diagnostics are employed to investigate plasma relaxation process. Magnetized Argon plasma bubbles with velocities ~1.2Cs and densities ~1020 m-3 have been achieved. Different distinct regimes of operation with qualitatively different dynamics are identified by fast CCD camera images, with the parameter determining the operation regime. Additionally, a B-dot probe array is employed to measure the spatial toroidal and poloidal magnetic flux evolution to identify detached plasma bubble configurations. Experimental data and analysis will be presented.

  4. Plasma Dark Current in Self-Ionized Plasma Wakefield Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Oz, E.; Deng, S.; Katsouleas, T.; Muggli, P.; /Southern California U.; Iverson, R.; Johnson, D.K.; Krejcik, P.; O' Connell, C.; Siemann, R.H.; Walz, D.; /SLAC; Clayton,; Huang, C.; Joshi, C.; Lu, W.; Marsh, K.A.; Mori, W.B.; Zhou, M.; /UCLA

    2006-01-30

    Evidence of particle trapping has been observed in a beam driven Plasma Wake Field Accelerator (PWFA) experiment, E164X, conducted at the Stanford Linear Accelerator Center by a collaboration which includes USC, UCLA and SLAC. Such trapping produces plasma dark current when the wakefield amplitude is above a threshold value and may place a limit on the maximum acceleration gradient in a PWFA. Trapping and dark current are enhanced when in an ionizing plasma, that is self-ionized by the beam. Here we present experimental results.

  5. Range of fractionated plasma products to optimize plasma resources

    Institute of Scientific and Technical Information of China (English)

    Thierry Burnouf

    2010-01-01

    @@ HUMAN PLASMA is a source material that is crucial for the production of unique therapeutic fractionated products. Indeed, plasma contains hundreds of proteins ensuring many physiological functions. The most abun-dant proteins, albumin and immunoglobulin G (IgG) ,are present at about 35 and 10 g/L,respectively,repre-senting about 80% of all plasma proteins. However,other important therapeutic proteins include the coagu-lation factors (factor Ⅷ (F Ⅷ) ; FIX ; Von Willebrand Factor (VWF), fibrinogen) various protease inhibitors (alpha 1-antitrypsin ; antithrombin; C1-esterase) and anticoagulants (protein C) which exhibit potent physi-ological activity.

  6. Laser Plasmas : Optical guiding of laser beam in nonuniform plasma

    Indian Academy of Sciences (India)

    Tarsem Singh Gill

    2000-11-01

    A plasma channel produced by a short ionising laser pulse is axially nonuniform resulting from the self-defocusing. Through such preformed plasma channel, when a delayed pulse propagates, the phenomena of diffraction, refraction and self-phase modulation come into play. We have solved the nonlinear parabolic partial differential equation governing the propagation characteristics for an approximate analytical solution using variational approach. Results are compared with the theoretical model of Liu and Tripathi (Phys. Plasmas 1, 3100 (1994)) based on paraxial ray approximation. Particular emphasis is on both beam width and longitudinal phase delay which are crucial to many applications.

  7. Negative Plasma Densities Raise Questions

    Energy Technology Data Exchange (ETDEWEB)

    Hazi, A

    2006-01-26

    Nearly all the matter encountered on Earth is either a solid, liquid, or gas. Yet plasma-the fourth state of matter-comprises more than 99 percent of the visible universe. Understanding the physical characteristics of plasmas is important to many areas of scientific research, such as the development of fusion as a clean, renewable energy source. Lawrence Livermore scientists study the physics of plasmas in their pursuit to create fusion energy, because plasmas are an integral part of that process. When deuterium and tritium are heated to the extreme temperatures needed to achieve and sustain a fusion reaction (about 100 million degrees), the electrons in these light atoms become separated from the nuclei. This process of separation is called ionization, and the resulting collection of negatively charged free electrons and positively charged nuclei is known as a plasma. Although plasmas and gases have many similar properties, plasmas differ from gases in that they are good conductors of electricity and can generate magnetic fields. For the past decade, x-ray laser interferometry has been used in the laboratory for measuring a plasma's index of refraction to determine plasma density. (The index of refraction for a given material is defined as the wavelength of light in a vacuum divided by the wavelength of light traveling through the material.) Until now, plasma physicists expected to find an index of refraction less than one. Researchers from Livermore and Colorado State University recently conducted experiments on aluminum plasmas at the Laboratory's COMET laser facility and observed results in which the index of refraction was greater than one. This surprising result implied a negative electron density. Livermore physicist Joseph Nilsen and his colleagues from Livermore and the University of Notre Dame have performed sophisticated calculations to explain this phenomenon. Previously, researchers believed that only free electrons contributed to the index

  8. Labotratory Simulation Experiments of Cometary Plasma

    OpenAIRE

    Minami, S; Baum, P. J.; Kamin, G.; R. S. White; 南, 繁行

    1986-01-01

    Laboratory simulation experiment to study the interaction between a cometary plasma and the solar wind has been performed using the UCR-T 1 space simulation facility at the Institute of Geophysics and Planetary Physics, the University of California, Riverside. Light emitting plasma composed of Sr, Ba and/or C simulating cometary coma plasma is produced by a plasma emitter which interacts with intense plasma flow produced by a co-axial plasma gun simulating the solar wind. The purpose of this ...

  9. Waves in plasmas (part 1 - wave-plasma interaction general background); Ondes dans les plasmas (Partie 1 - interaction onde / plasma: bases physiques)

    Energy Technology Data Exchange (ETDEWEB)

    Dumont, R

    2004-07-01

    This document gathers a series of transparencies presented in the framework of the week-long lectures 'hot plasmas 2004' and dedicated to the physics of wave-plasma interaction. The structure of this document is as follows: 1) wave and diverse plasmas, 2) basic equations (Maxwell equations), 3) waves in a fluid plasma, and 4) waves in a kinetic plasma (collisionless plasma)

  10. Development of a Rat Plasma and Brain Extracellular Fluid Pharmacokinetic Model for Bupropion and Hydroxybupropion Based on Microdialysis Sampling, and Application to Predict Human Brain Concentrations.

    Science.gov (United States)

    Cremers, Thomas I F H; Flik, Gunnar; Folgering, Joost H A; Rollema, Hans; Stratford, Robert E

    2016-05-01

    Administration of bupropion [(±)-2-(tert-butylamino)-1-(3-chlorophenyl)propan-1-one] and its preformed active metabolite, hydroxybupropion [(±)-1-(3-chlorophenyl)-2-[(1-hydroxy-2-methyl-2-propanyl)amino]-1-propanone], to rats with measurement of unbound concentrations by quantitative microdialysis sampling of plasma and brain extracellular fluid was used to develop a compartmental pharmacokinetics model to describe the blood-brain barrier transport of both substances. The population model revealed rapid equilibration of both entities across the blood-brain barrier, with resultant steady-state brain extracellular fluid/plasma unbound concentration ratio estimates of 1.9 and 1.7 for bupropion and hydroxybupropion, respectively, which is thus indicative of a net uptake asymmetry. An overshoot of the brain extracellular fluid/plasma unbound concentration ratio at early time points was observed with bupropion; this was modeled as a time-dependent uptake clearance of the drug across the blood-brain barrier. Translation of the model was used to predict bupropion and hydroxybupropion exposure in human brain extracellular fluid after twice-daily administration of 150 mg bupropion. Predicted concentrations indicate that preferential inhibition of the dopamine and norepinephrine transporters by the metabolite, with little to no contribution by bupropion, would be expected at this therapeutic dose. Therefore, these results extend nuclear imaging studies on dopamine transporter occupancy and suggest that inhibition of both transporters contributes significantly to bupropion's therapeutic efficacy.

  11. Evaluation of Sample Stability and Automated DNA Extraction for Fetal Sex Determination Using Cell-Free Fetal DNA in Maternal Plasma

    Directory of Open Access Journals (Sweden)

    Elena Ordoñez

    2013-01-01

    Full Text Available Objective. The detection of paternally inherited sequences in maternal plasma, such as the SRY gene for fetal sexing or RHD for fetal blood group genotyping, is becoming part of daily routine in diagnostic laboratories. Due to the low percentage of fetal DNA, it is crucial to ensure sample stability and the efficiency of DNA extraction. We evaluated blood stability at 4°C for at least 24 hours and automated DNA extraction, for fetal sex determination in maternal plasma. Methods. A total of 158 blood samples were collected, using EDTA-K tubes, from women in their 1st trimester of pregnancy. Samples were kept at 4°C for at least 24 hours before processing. An automated DNA extraction was evaluated, and its efficiency was compared with a standard manual procedure. The SRY marker was used to quantify cfDNA by real-time PCR. Results. Although lower cfDNA amounts were obtained by automated DNA extraction (mean 107,35 GE/mL versus 259,43 GE/mL, the SRY sequence was successfully detected in all 108 samples from pregnancies with male fetuses. Conclusion. We successfully evaluated the suitability of standard blood tubes for the collection of maternal blood and assessed samples to be suitable for analysis at least 24 hours later. This would allow shipping to a central reference laboratory almost from anywhere in Europe.

  12. Plasma Nanoscience: from Nano-Solids in Plasmas to Nano-Plasmas in Solids

    CERN Document Server

    Ostrikov, K; Meyyappan, M

    2013-01-01

    The unique plasma-specific features and physical phenomena in the organization of nanoscale solid-state systems in a broad range of elemental composition, structure, and dimensionality are critically reviewed. These effects lead to the possibility to localize and control energy and matter at nanoscales and to produce self-organized nano-solids with highly unusual and superior properties. A unifying conceptual framework based on the control of production, transport, and self-organization of precursor species is introduced and a variety of plasma-specific non-equilibrium and kinetics-driven phenomena across the many temporal and spatial scales is explained. When the plasma is localized to micrometer and nanometer dimensions, new emergent phenomena arise. The examples range from semiconducting quantum dots and nanowires, chirality control of single-walled carbon nanotubes, ultra-fine manipulation of graphenes, nano-diamond, and organic matter, to nano-plasma effects and nano-plasmas of different states of matter...

  13. Impaired plasma lipid profiles in acute hepatitis

    Directory of Open Access Journals (Sweden)

    Wang Yongzhong

    2010-01-01

    Full Text Available Abstract The present study examined plasma lipid profiles in thirty patients suffered from acute viral hepatitis. Patients' blood samples were collected at both the debut and recovery of diseases. Thirty sex and age matched normal subjects were included as controls. Plasma total triglycerides (TG, total cholesterol, high density lipoprotein cholesterol (HDL-C, low density lipoprotein cholesterol (LDL-C, apolipoprotein AI (ApoAI, apolipoprotein B (ApoB, lipoprotein (a (Lp(a, blood coagulation status including prothrombin complex activity and activated partial tromboplastin time (APTT, and hepatic functions were determined by the automatic biochemical analytical instrument. It demonstrated that plasma levels of total cholesterol, HDL-C and apoAI were significantly lower in the patients at the acute phase of hepatitis than those in normal subjects, whereas plasma levels of TG and LDL-C were obviously higher in the patients than in normal subjects (P

  14. Plasma medicine: an introductory review

    Science.gov (United States)

    Kong, M. G.; Kroesen, G.; Morfill, G.; Nosenko, T.; Shimizu, T.; van Dijk, J.; Zimmermann, J. L.

    2009-11-01

    This introductory review on plasma health care is intended to provide the interested reader with a summary of the current status of this emerging field, its scope, and its broad interdisciplinary approach, ranging from plasma physics, chemistry and technology, to microbiology, biochemistry, biophysics, medicine and hygiene. Apart from the basic plasma processes and the restrictions and requirements set by international health standards, the review focuses on plasma interaction with prokaryotic cells (bacteria), eukaryotic cells (mammalian cells), cell membranes, DNA etc. In so doing, some of the unfamiliar terminology—an unavoidable by-product of interdisciplinary research—is covered and explained. Plasma health care may provide a fast and efficient new path for effective hospital (and other public buildings) hygiene—helping to prevent and contain diseases that are continuously gaining ground as resistance of pathogens to antibiotics grows. The delivery of medically active 'substances' at the molecular or ionic level is another exciting topic of research through effects on cell walls (permeabilization), cell excitation (paracrine action) and the introduction of reactive species into cell cytoplasm. Electric fields, charging of surfaces, current flows etc can also affect tissue in a controlled way. The field is young and hopes are high. It is fitting to cover the beginnings in New Journal of Physics, since it is the physics (and non-equilibrium chemistry) of room temperature atmospheric pressure plasmas that have made this development of plasma health care possible.

  15. Plasma Treatments and Biomass Gasification

    Science.gov (United States)

    Luche, J.; Falcoz, Q.; Bastien, T.; Leninger, J. P.; Arabi, K.; Aubry, O.; Khacef, A.; Cormier, J. M.; Lédé, J.

    2012-02-01

    Exploitation of forest resources for energy production includes various methods of biomass processing. Gasification is one of the ways to recover energy from biomass. Syngas produced from biomass can be used to power internal combustion engines or, after purification, to supply fuel cells. Recent studies have shown the potential to improve conventional biomass processing by coupling a plasma reactor to a pyrolysis cyclone reactor. The role of the plasma is twofold: it acts as a purification stage by reducing production of tars and aerosols, and simultaneously produces a rich hydrogen syngas. In a first part of the paper we present results obtained from plasma treatment of pyrolysis oils. The outlet gas composition is given for various types of oils obtained at different experimental conditions with a pyrolysis reactor. Given the complexity of the mixtures from processing of biomass, we present a study with methanol considered as a model molecule. This experimental method allows a first modeling approach based on a combustion kinetic model suitable to validate the coupling of plasma with conventional biomass process. The second part of the paper is summarizing results obtained through a plasma-pyrolysis reactor arrangement. The goal is to show the feasibility of this plasma-pyrolysis coupling and emphasize more fundamental studies to understand the role of the plasma in the biomass treatment processes.

  16. Thomson scattering from laser plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Moody, J D; Alley, W E; De Groot, J S; Estabrook, K G; Glenzer, S H; Hammer, J H; Jadaud, J P; MacGowan, B J; Rozmus, W; Suter, L J; Williams, E A

    1999-01-12

    Thomson scattering has recently been introduced as a fundamental diagnostic of plasma conditions and basic physical processes in dense, inertial confinement fusion plasmas. Experiments at the Nova laser facility [E. M. Campbell et al., Laser Part. Beams 9, 209 (1991)] have demonstrated accurate temporally and spatially resolved characterization of densities, electron temperatures, and average ionization levels by simultaneously observing Thomson scattered light from ion acoustic and electron plasma (Langmuir) fluctuations. In addition, observations of fast and slow ion acous- tic waves in two-ion species plasmas have also allowed an independent measurement of the ion temperature. These results have motivated the application of Thomson scattering in closed-geometry inertial confinement fusion hohlraums to benchmark integrated radiation-hydrodynamic modeling of fusion plasmas. For this purpose a high energy 4{omega} probe laser was implemented recently allowing ultraviolet Thomson scattering at various locations in high-density gas-filled hohlraum plasmas. In partic- ular, the observation of steep electron temperature gradients indicates that electron thermal transport is inhibited in these gas-filled hohlraums. Hydrodynamic calcula- tions which include an exact treatment of large-scale magnetic fields are in agreement with these findings. Moreover, the Thomson scattering data clearly indicate axial stagnation in these hohlraums by showing a fast rise of the ion temperature. Its timing is in good agreement with calculations indicating that the stagnating plasma will not deteriorate the implosion of the fusion capsules in ignition experiments.

  17. Couette Flow of Unmagnetized Plasma

    CERN Document Server

    Collins, C; Cooper, C M; Flanagan, K; Khalzov, I V; Nornberg, M D; Seidlitz, B; Wallace, J; Forest, C B

    2014-01-01

    Differentially rotating flows of unmagnetized, highly conducting plasmas have been created in the Plasma Couette Experiment. Previously, hot-cathodes have been used to control plasma rotation by a stirring technique [C. Collins et al., Phys. Rev. Lett. 108, 115001(2012)] on the outer cylindrical boundary---these plasmas were nearly rigid rotors, modified only by the presence of a neutral particle drag. Experiments have now been extended to include stirring from an inner boundary, allowing for generalized Couette flow and opening a path for both hydrodynamic and magnetohydrodynamic experiments, as well as fundamental studies of plasma viscosity. Plasma is confined in a cylindrical, axisymmetric, multicusp magnetic field, with $T_e< 10$ eV, $T_i<1$ eV, and $n_e<10^{11}$ cm$^{-3}$. Azimuthal flows (up to 12 km/s, $M=V/c_s\\sim 0.7$) are driven by edge ${\\bf J \\times B}$ torques in helium, neon, argon, and xenon plasmas. We present measurements of a self-consistent, rotation-induced, species-dependent rad...

  18. Special issue on transient plasmas

    Science.gov (United States)

    Bailey, James; Hoarty, David; Mancini, Roberto; Yoneda, Hitoki

    2015-11-01

    This special issue of Journal of Physics B: Atomic, Molecular and Optical Physics is dedicated to the "spectroscopy of transient plasmas" covering plasma conditions produced by a range of pulsed laboratory sources including short and long pulse lasers, pulsed power devices, and free electron lasers (FELs). The full range of plasma spectroscopy up to high energy bremsstrahlung radiation, including line broadening analysis for application to data recorded with the ChemCam instrument on the Mars Science Laboratory rover Curiosity, is covered. This issue is timely as advances in optical lasers and x-ray FELs (XFEL) are enabling transient plasma to be probed at higher energies and shorter durations than ever before. New XFEL facilities being commissioned in Europe and Asia are adding to those operating in the US and Japan and the ELI high power laser project in Europe, due to open this year, will provide short pulse lasers of unprecedented power. This special issue represents a snapshot of the theoretical and experimental research in dense plasmas, electron kinetics, laser-induced breakdown spectroscopy of low temperature plasmas, inertial confinement fusion and non-equilibrium atomic physics using spectroscopy to diagnose plasmas produced by optical lasers, XFELs and pulsed-power machines.

  19. Modeling the Europa plasma torus

    Science.gov (United States)

    Schreier, Ron; Eviatar, Aharon; Vasyliunas, Vytenis M.; Richardson, John D.

    1993-12-01

    The existence of a torus of plasma generated by sputtering from Jupiter's satellite Europa has long been suspected but never yet convincingly demonstrated. Temperature profiles from Voyager plasma observations indicate the presence of hot, possibly freshly picked-up ions in the general vicinity of the orbit of Europa, which may be interpreted as evidence for a local plasma torus. Studies of ion partitioning in the outer regions of the Io torus reveal that the oxygen to sulfur mixing ratio varies with radial distance; this may indicates that oxygen-rich matter is injected from a non-Io source, most probably Europa. We have constructed a quantitative model of a plasma torus near the orbit of Europa which takes into account plasma input from the Io torus, sputtering from the surface of Europa, a great number of ionization and charge exchange processes, and plasma loss by diffusive transport. When the transport time is chosen so that the model's total number density in consistent with the observed total plasma density, the contribution from Europa is found to be significant although not dominant. The model predicts in detail the ion composition, charge states, and the relative fractions of hot Europa-generated and (presumed) cold Io-generated ions. The results are generally consistent with observations from Voyager and can in principle (subject to limitations of data coverage) be confirmed in more detail by Ulysses.

  20. Cold plasma decontamination of foods.

    Science.gov (United States)

    Niemira, Brendan A

    2012-01-01

    Cold plasma is a novel nonthermal food processing technology that uses energetic, reactive gases to inactivate contaminating microbes on meats, poultry, fruits, and vegetables. This flexible sanitizing method uses electricity and a carrier gas, such as air, oxygen, nitrogen, or helium; antimicrobial chemical agents are not required. The primary modes of action are due to UV light and reactive chemical products of the cold plasma ionization process. A wide array of cold plasma systems that operate at atmospheric pressures or in low pressure treatment chambers are under development. Reductions of greater than 5 logs can be obtained for pathogens such as Salmonella, Escherichia coli O157:H7, Listeria monocytogenes, and Staphylococcus aureus. Effective treatment times can range from 120 s to as little as 3 s, depending on the food treated and the processing conditions. Key limitations for cold plasma are the relatively early state of technology development, the variety and complexity of the necessary equipment, and the largely unexplored impacts of cold plasma treatment on the sensory and nutritional qualities of treated foods. Also, the antimicrobial modes of action for various cold plasma systems vary depending on the type of cold plasma generated. Optimization and scale up to commercial treatment levels require a more complete understanding of these chemical processes. Nevertheless, this area of technology shows promise and is the subject of active research to enhance efficacy.