WorldWideScience

Sample records for plasma operating parameters

  1. The effect of plasma operating parameters on analyte signals in inductively coupled plasma-mass spectrometry

    Science.gov (United States)

    Horlick, G.; Tan, S. H.; Vaughan, M. A.; Rose, C. A.

    Utilizing the SCIEX ICP-MS an extensive study of the effects that plasma operating parameters have on analyte ion signals in ICP-MS has been carried out. Parameters studied included aerosol flow rate (nebulizer pressure), auxiliary flow rate, power and sampling depth (sampling position from the load coil). The two key parameters are aerosol flow rate (nebulizer pressure) and power. Elements can be grouped into characteristic behaviour patterns based on the overall dependence of their ion count signal on these two parameters. The nebulizer pressure-power behavior patterns allow a sensible selection of compromise operating conditions and significantly clarify single parameter observations which often indicate confusing trends in behavior. In addition to characterizing analyte ion signals the parameter behavior plots have also been used to study oxide species and plus two ions in ICP-MS. While aerosol flow rate and power appear to be the key ICP parameters in ICP-MS, ion signals are dependent on sampling depth and auxiliary flow rate and some data are also presented illustrating the signal dependence on these two parameters.

  2. Plasma parameter characterization of a dc multicusp plasma chamber operating in He, Ar and Xe gas

    Energy Technology Data Exchange (ETDEWEB)

    Suanpoot, Pradoong; Vilaithong, Thiraphat; Boonyawan, Dheerawan [Fast Neutron Research Facility, Dept. of Physics, Faculty of Science, Chiang Mai Univ. (Thailand); Rhodes, M.W.

    1998-12-31

    A large dc multicusp plasma chamber has been constructed and installed at Chiang Mai University. The first prototype has a 31.2 cm diameter and a 42.5 cm length and is surrounded by 632 ceramic permanent magnet buttons with a maximum magnetic field of about 2.2 kG for each. The magnetic field at the stainless steel wall with a thickness of 2 mm is about 670 G. A tungsten (W) filament was used as a source of primary electrons. The estimated discharge voltage for helium gas (He), argon gas (Ar), and xenon gas (Xe) was 40 V and the discharge operating current varies from 500 mA to 1 A. Plasmas can be confined within a 20 cm diameter region which are uniformly distributed along the axial path. The plasma density was measured by a single cylindrical Langmuir probe to be between 4.8 x 10{sup 8} - 4.9 x 10{sup 9} cm{sup -3} with 650 watts of power applied to the tungsten filament and the gas pressure inside the chamber of 3.8 x 10{sup -4} Torr. Results of the ion density measurements are described. The proportionality constants in the relation between the ion current density arriving at the plasma electrode and the maximum plasma density and the ion sound speed for helium, argon and xenon are found to be 0.42 {+-} 0.07, 0.59 {+-} 0.08, and 0.46 {+-} 0.06, respectively. (author)

  3. Mechanism and operation parameters of a plasma-driven micro-particle accelerator

    Institute of Scientific and Technical Information of China (English)

    HUANG JianGuo; FENG ChunHua; HAN dianWei; LI HongWei; CAI MingHui; LI XiaoYin; ZHANG ZhenLong; CHEN ZhaoFeng; WANG Long; YANG XuanZong

    2009-01-01

    There is a large amount of micro debris ranging between millimeters and micrometers in space, which has significant influence on the reliability and life of spacecrafts through long-duration integrated im-pacts and has to be considered in designing a vehicle's suitability to the space environment. In order to simulate the micro-impacts on exposed materials, a plasma-driven micro-particle accelerator was de-veloped. The major processes, including the acceleration, compression and ejection of plasmas, were modeled. By comparing the theoretical simulations with the experimental results, the acceleration mechanism was clarified. Moreover, through a series of experiments, the optimum operation range was investigated, and the acceleration ability was primarily determined.

  4. Evaluation of the operational parameters for NBI-driven fusion in low-gain tokamaks with two-component plasma

    Science.gov (United States)

    Chirkov, A. Yu.

    2015-09-01

    Low gain (Q ~ 1) fusion plasma systems are of interest for concepts of fusion-fission hybrid reactors. Operational regimes of large modern tokamaks are close to Q  ≈  1. Therefore, they can be considered as prototypes of neutron sources for fusion-fission hybrids. Powerful neutral beam injection (NBI) can support the essential population of fast particles compared with the Maxwellial population. In such two-component plasma, fusion reaction rate is higher than for Maxwellian plasma. Increased reaction rate allows the development of relatively small-size and relatively inexpensive neutron sources. Possible operating regimes of the NBI-heated tokamak neutron source are discussed. In a relatively compact device, the predictions of physics of two-component fusion plasma have some volatility that causes taking into account variations of the operational parameters. Consequent parameter ranges are studied. The feasibility of regimes with Q  ≈  1 is shown for the relatively small and low-power system. The effect of NBI fraction in total heating power is analyzed.

  5. Interaction of CLAM Steel with Plasma in HT-7 Tokamak During High Parameter Operation

    Institute of Scientific and Technical Information of China (English)

    LI Chunjing; HUANG Qunying; FENG Yan; LI Jiangang; KONG Mingguang

    2007-01-01

    A Plasma Surface Interaction(PSI)experiment on China Low Activation Martensitic(CLAM)steel was done to check if CLAM steel could be used as a Plasma Facing Material (PFM).A specimen with a diameter of 45 mm was exposed to 897 shots of deuterium plasmas with a total duration of 712 sec at a minor radius of 30 cm in HT-7 tokamak.During the exposure experiment,no observable influence Was found on plasma performance.After exposure,the surface of the specimen seemed as smooth as before but with some colour change at the margin of the specimen.Even though some micro-damage,such as dense blisters,melting,splashing,depositions,and dust,Was found on local surfaces with Scanning Electron Microscopic(SEM)observation.The reflectivity of the specimen decreased only slightly.All of these shows CLAM steel has good stability and irradiation resistance.With further optimization,it could possibly be used as the first mirror material for plasma diagnostics in tokamaks.

  6. Divertor Plasma Parameters During Radiative Divertor Operation on DIII--D

    Science.gov (United States)

    Allen, S. L.; Fenstermacher, M. E.; Hill, D. N.; Lasnier, C. J.; Meyer, W. H.; Porter, G. D.; Wood, R. D.; Leonard, A. W.; Mahdavi, M. A.; Petrie, T. W.; West, W. P.; Maingi, R.; Wade, M. R.; Whyte, D. G.

    1996-11-01

    A large array of divertor diagnostics has been used to characterize the DIII--D divertor conditions during radiative divertor operation. We have used both D2 and impurities to reduce the divertor heat flux. Several discharge conditions have been obtained, including attached and detached ELMing H-modes. The multi-chord Divertor Thomson Scattering (DTS) system has been used with divertor sweeping to obtain 2-D measurements of ne and Te in the divertor. The Te drops to <= 2 eV with D2 puffing, ne increases, and the electron pressure Pe decreases. The radiation zone, measured by multi-chord bolometry, moves from the inside leg of the divertor to the outside. Comparisons of the 2-D distribution of ne and Te and the radiation distribution will be presented.

  7. Influence of operating parameters on surface properties of RF glow discharge oxygen plasma treated TiO{sub 2}/PET film for biomedical application

    Energy Technology Data Exchange (ETDEWEB)

    Pandiyaraj, K. Navaneetha, E-mail: dr.knpr@gmail.com [Surface Engineering Laboratory, Department of Physics, Sri Shakthi Institute of Engineering and Technology, L and T by pass, Chinniyam Palayam (post), Coimbatore 641062 (India); Deshmukh, R.R. [Department of Physics, Institute of Chemical Technology, Matunga, Mumbai 400 019 (India); Mahendiran, R. [Surface Engineering Laboratory, Department of Physics, Sri Shakthi Institute of Engineering and Technology, L and T by pass, Chinniyam Palayam (post), Coimbatore 641062 (India); Su, Pi-G [Department of Chemistry, Chinese Culture University, Taipei 111, Taiwan (China); Yassitepe, Emre; Shah, Ismat [Department of Physics and Astronomy, Department of Materials Science and Engineering, University of Delaware, 208 Dupont Hall, Newark (United States); Perni, Stefano [School of Pharmacy and Pharmaceutical Sciences, Cardiff University, Cardiff (United Kingdom); Prokopovich, Polina [School of Pharmacy and Pharmaceutical Sciences, Cardiff University, Cardiff (United Kingdom); Institute of Medical Engineering and Medical Physics, School of Engineering, Cardiff University (United Kingdom); Nadagouda, Mallikarjuna N., E-mail: Nadagouda.Mallikarjuna@epamail.epa.gov [The U.S. Environmental Protection Agency, ORD, NRMRL, WSWRD, 26W. Martin Luther King Drive, Cincinnati, OH 45268 (United States)

    2014-03-01

    In this paper, a thin transparent titania (TiO{sub 2}) film was coated on the surface of flexible poly(ethylene terephthalate) (PET) film using the sol–gel method. The surface properties of the obtained TiO{sub 2}/PET film were further improved by RF glow discharge oxygen plasma as a function of exposure time and discharge power. The changes in hydrophilicity of TiO{sub 2}/PET films were analyzed by contact angle measurements and surface energy. The influence of plasma on the surface of the TiO{sub 2}/PET films was analyzed by atomic force microscopy (AFM) as well as the change in chemical state and composition that were investigated by X-ray photo electron spectroscopy (XPS). The cytotoxicity of the TiO{sub 2}/PET films was analyzed using human osteoblast cells and the bacterial eradication behaviors of TiO{sub 2}/PET films were also evaluated against Staphylococcus bacteria. It was found that the surface roughness and incorporation of oxygen containing polar functional groups of the plasma treated TiO{sub 2}/PET films increased substantially as compared to the untreated one. Moreover the increased concentration of Ti{sup 3+} on the surface of plasma treated TiO{sub 2}/PET films was due to the transformation of chemical states (Ti{sup 4+} → Ti{sup 3+}). These morphological and chemical changes are responsible for enhanced hydrophilicity of the TiO{sub 2}/PET films. Furthermore, the plasma treated TiO{sub 2}/PET film exhibited no citotoxicity against osteoblast cells and antibacterial activity against Staphylococcus bacteria which can find application in manufacturing of biomedical devices. - Graphical abstract: Mechanism of plasma treatment on the surface of TiO{sub 2}/PET films. - Highlights: • Investigated the surface properties of TiO{sub 2}/PET films modified by O{sub 2} plasma • Studied the effect of operating parameters on surface properties of TiO{sub 2}/PET films • Mechanism of the plasma treatment on TiO{sub 2}/PET was clearly investigated.

  8. Chapter 8: Plasma operation and control

    Science.gov (United States)

    Gribov, Y.; Humphreys, D.; Kajiwara, K.; Lazarus, E. A.; Lister, J. B.; Ozeki, T.; Portone, A.; Shimada, M.; Sips, A. C. C.; Wesley, J. C.

    2007-06-01

    The ITER plasma control system has the same functional scope as the control systems in present tokamaks. These are plasma operation scenario sequencing, plasma basic control (magnetic and kinetic), plasma advanced control (control of RWMs, NTMs, ELMs, error fields, etc) and plasma fast shutdown. This chapter considers only plasma initiation and plasma basic control. This chapter describes the progress achieved in these areas in the tokamak experiments since the ITER Physics Basis (1999 Nucl. Fusion 39 2577) was written and the results of assessment of ITER to provide the plasma initiation and basic control. This assessment was done for the present ITER design (15 MA machine) at a more detailed level than it was done for the ITER design 1998 (21 MA machine) described in the ITER Physics Basis (1999 Nucl. Fusion 39 2577). The experiments on plasma initiation performed in DIII-D and JT-60U, as well as the theoretical studies performed for ITER, have demonstrated that, within specified assumptions on the plasma confinement and the impurity influx, ITER can produce plasma initiation in a low toroidal electric field (0.3 V m-1), if it is assisted by about 2 MW of ECRF heating. The plasma basic control includes control of the plasma current, position and shape—the plasma magnetic control, as well as control of other plasma global parameters or their profiles—the plasma performance control. The magnetic control is based on more reliable and simpler models of the control objects than those available at present for the plasma kinetic control. Moreover the real time diagnostics used for the magnetic control in many cases are more precise than those used for the kinetic control. Because of these reasons, the plasma magnetic control was developed for modern tokamaks and assessed for ITER better than the kinetic control. However, significant progress has been achieved in the plasma performance control during the last few years. Although the physics basis of plasma operation

  9. Plasma diagnostics discharge parameters and chemistry

    CERN Document Server

    Auciello, Orlando

    1989-01-01

    Plasma Diagnostics, Volume 1: Discharge Parameters and Chemistry covers seven chapters on the important diagnostic techniques for plasmas and details their use in particular applications. The book discusses optical diagnostic techniques for low pressure plasmas and plasma processing; plasma diagnostics for electrical discharge light sources; as well as Langmuir probes. The text also describes the mass spectroscopy of plasmas, microwave diagnostics, paramagnetic resonance diagnostics, and diagnostics in thermal plasma processing. Electrical engineers, nuclear engineers, microwave engineers, che

  10. Sensor for monitoring plasma parameters

    CERN Document Server

    Bolshakov, A A; Sharma, S P; Bol'shakov, Alexander A.; Cruden, Brett A.; Sharma, Surendra P.

    2004-01-01

    A spectrally tunable VCSEL (vertical cavity surface-emitting laser) was used as part of sensing hardware for measurements of the radial-integrated gas temperature inside an inductively coupled plasma reactor. The data were obtained by profiling the Doppler-broadened absorption of metastable Ar atoms at 763.51 nm in argon and argon/nitrogen plasmas (3, 45, and 90% N2 in Ar) at pressure 0.5-70 Pa and inductive power of 100 and 300 W. The results were compared to rotational temperature derived from the N2 emission at the (0,0) transition of the C - B system. The differences in integrated rotational and Doppler temperatures were attributed to non-uniform spatial distributions of both temperature and thermometric species (Ar* and N2*) that varied depending on conditions. A two-dimensional, two-temperature fluid plasma simulation was employed to explain these differences. This work should facilitate further development of a miniature sensor for non-intrusive acquisition of data (temperature and densities of multipl...

  11. Numerical Simulation of Basic Parameters in Plasma Spray

    Institute of Scientific and Technical Information of China (English)

    范群波; 王鲁; 王富耻

    2004-01-01

    On the basis of energy balance in the plasma gas, a new, simplified but effective mathematical model is developed to predict the temperature, velocity and ionization degrees of different species at the torch exit, which can be directly calculated just by inputting the general spraying parameters, such as current, voltage, flow rates of gases, etc. Based on this method, the effects of plasma current and the flow rate of Ar on the basic parameters at the torch exit are discussed. The results show that the temperature, velocity and ionization degrees of gas species will increase with increasing the plasma current; while increasing Ar flow rate can increase the velocity at the exit but decrease the temperature and ionization degrees of plasma species. The method would be helpful to predict the temperature and velocity fields in a plasma jet in future, and direct the practical plasma spray operations.

  12. Study of parameters of a facility generating compressive plasma flows

    Science.gov (United States)

    Leyvi, A. Ya

    2017-05-01

    The prosperity of plasma technologies stimulates making of a facility generating compressive plasma flows at the South Ural State University. The facility is a compact-geometry magnetoplasma compressor with the following parameters: stored energy up to 15 kJ, voltage of a bank from 3 to 5 kV; nitrogen, air, and other gases can serve as its operating gas. The investigation of parameters of the facility showed the following parameters of compressive plasma flows: impulse duration of up to 120 μs, discharge current of 50-120 kA, speed of plasma flow of 15-30 km/s. By contrast to the available facilities, the parameters of the developed facility can be adjusted in a wide range of voltage from 2 kV to 10 kV, its design permits generating CPF in horizontal and vertical positions.

  13. Study on Performance Parameters of the Plasma Source for a Short-Conduction-Time Plasma Opening Switch

    Institute of Scientific and Technical Information of China (English)

    LUO Weixi; ZENG Zhengzhong; WANG Liangping; LEI Tianshi; HU Yixiang; HUANG Tao; SUN Tieping

    2012-01-01

    Plasma source performance parameters, including plasma ejection density and velocity, greatly affect the operation of a short-conduction-time plasma opening switch (POS). In this paper, the plasma source used in the POS of Qiangguang I generator is chosen as the study object. At first the POS working process is analyzed. The result shows that the opening performance of the POS can be improved by increasing the plasma ejection velocity and decreasing the plasma density. The influence of the cable plasma gun structure and number on the plasma ejection parameters is experimentally investigated with two charge collectors. Finally a semi-empirical model is proposed to describe the experimental phenomenon.

  14. Surface wave and linear operating mode of a plasma antenna

    Energy Technology Data Exchange (ETDEWEB)

    Bogachev, N. N., E-mail: bgniknik@yandex.ru; Bogdankevich, I. L.; Gusein-zade, N. G.; Rukhadze, A. A. [Russian Academy of Sciences, Prokhorov General Physics Institute (Russian Federation)

    2015-10-15

    The relation between the propagation conditions of a surface electromagnetic wave along a finiteradius plasma cylinder and the linear operating mode of a plasma antenna is investigated. The solution to the dispersion relation for a surface wave propagating along a finite-radius plasma cylinder is analyzed for weakly and strongly collisional plasmas. Computer simulations of an asymmetrical plasma dipole antenna are performed using the KARAT code, wherein the dielectric properties of plasma are described in terms of the Drude model. The plasma parameters corresponding to the linear operating mode of a plasma antenna are determined. It is demonstrated that the characteristics of the plasma antenna in this mode are close to those of an analogous metal antenna.

  15. Optimization of audio - ultrasonic plasma system parameters

    Science.gov (United States)

    Haleem, N. A.; Abdelrahman, M. M.; Ragheb, M. S.

    2016-10-01

    The present plasma is a special glow plasma type generated by an audio ultrasonic discharge voltage. A definite discharge frequency using a gas at a narrow band pressure creates and stabilizes this plasma type. The plasma cell is a self-extracted ion beam; it is featured with its high output intensity and its small size. The influence of the plasma column length on the output beam due to the variation of both the audio discharge frequency and the power applied to the plasma electrodes is investigated. In consequence, the aim of the present work is to put in evidence the parameters that influence the self-extracted collected ion beam and to optimize the conditions that enhance the collected ion beam. The experimental parameters studied are the nitrogen gas, the applied frequency from 10 to 100 kHz, the plasma length that varies from 8 to 14 cm, at a gas pressure of ≈ 0.25 Torr and finally the discharge power from 50 to 500 Watt. A sheet of polyethylene of 5 micrometer covers the collector electrode in order to confirm how much ions from the beam can go through the polymer and reach the collector. To diagnose the occurring events of the beam on the collector, the polymer used is analyzed by means of the FTIR and the XRF techniques. Optimization of the plasma cell parameters succeeded to enhance and to identify the parameters that influence the output ion beam and proved that its particles attaining the collector are multi-energetic.

  16. Sensitivity of transient synchrotron radiation to tokamak plasma parameters

    Energy Technology Data Exchange (ETDEWEB)

    Fisch, N.J.; Kritz, A.H.

    1988-12-01

    Synchrotron radiation from a hot plasma can inform on certain plasma parameters. The dependence on plasma parameters is particularly sensitive for the transient radiation response to a brief, deliberate, perturbation of hot plasma electrons. We investigate how such a radiation response can be used to diagnose a variety of plasma parameters in a tokamak. 18 refs., 13 figs.

  17. Low voltage operation of plasma focus.

    Science.gov (United States)

    Shukla, Rohit; Sharma, S K; Banerjee, P; Das, R; Deb, P; Prabahar, T; Das, B K; Adhikary, B; Shyam, A

    2010-08-01

    Plasma foci of compact sizes and operating with low energies (from tens of joules to few hundred joules) have found application in recent years and have attracted plasma-physics scientists and engineers for research in this direction. We are presenting a low energy and miniature plasma focus which operates from a capacitor bank of 8.4 muF capacity, charged at 4.2-4.3 kV and delivering approximately 52 kA peak current at approximately 60 nH calculated circuit inductance. The total circuit inductance includes the plasma focus inductance. The reported plasma focus operates at the lowest voltage among all reported plasma foci so far. Moreover the cost of capacitor bank used for plasma focus is nearly 20 U.S. dollars making it very cheap. At low voltage operation of plasma focus, the initial breakdown mechanism becomes important for operation of plasma focus. The quartz glass tube is used as insulator and breakdown initiation is done on its surface. The total energy of the plasma focus is approximately 75 J. The plasma focus system is made compact and the switching of capacitor bank energy is done by manual operating switch. The focus is operated with hydrogen and deuterium filled at 1-2 mbar.

  18. Influence of Operating Parameters on Surface Properties of RF Glow Discharge Oxygen Plasma Treated TiO2/PET Film for Biomedical Application

    Science.gov (United States)

    Thin transparent titania (TiO2) films were coated on the surface of flexible poly (ethylene terephthalate) (PET) surface using standard sol gel techniques. The TiO2/PET thin film surfaces were further modified by exposing the films to a RF glow discharge oxygen plasma. The exposu...

  19. Influence of Operating Parameters on Surface Properties of RF Glow Discharge Oxygen Plasma Treated TiO2/PET Film for Biomedical Application

    Science.gov (United States)

    Thin transparent titania (TiO2) films were coated on the surface of flexible poly (ethylene terephthalate) (PET) surface using standard sol gel techniques. The TiO2/PET thin film surfaces were further modified by exposing the films to a RF glow discharge oxygen plasma. The exposu...

  20. Influence of operating parameters on surface properties of RF glow discharge oxygen plasma treated TiO₂/PET film for biomedical application.

    Science.gov (United States)

    Pandiyaraj, K Navaneetha; Deshmukh, R R; Mahendiran, R; Su, Pi-G; Yassitepe, Emre; Shah, Ismat; Perni, Stefano; Prokopovich, Polina; Nadagouda, Mallikarjuna N

    2014-03-01

    In this paper, a thin transparent titania (TiO2) film was coated on the surface of flexible poly(ethylene terephthalate) (PET) film using the sol-gel method. The surface properties of the obtained TiO2/PET film were further improved by RF glow discharge oxygen plasma as a function of exposure time and discharge power. The changes in hydrophilicity of TiO2/PET films were analyzed by contact angle measurements and surface energy. The influence of plasma on the surface of the TiO2/PET films was analyzed by atomic force microscopy (AFM) as well as the change in chemical state and composition that were investigated by X-ray photo electron spectroscopy (XPS). The cytotoxicity of the TiO2/PET films was analyzed using human osteoblast cells and the bacterial eradication behaviors of TiO2/PET films were also evaluated against Staphylococcus bacteria. It was found that the surface roughness and incorporation of oxygen containing polar functional groups of the plasma treated TiO2/PET films increased substantially as compared to the untreated one. Moreover the increased concentration of Ti(3+) on the surface of plasma treated TiO2/PET films was due to the transformation of chemical states (Ti(4+)→Ti(3+)). These morphological and chemical changes are responsible for enhanced hydrophilicity of the TiO2/PET films. Furthermore, the plasma treated TiO2/PET film exhibited no citotoxicity against osteoblast cells and antibacterial activity against Staphylococcus bacteria which can find application in manufacturing of biomedical devices.

  1. Underwater operation of a DBD plasma jet

    Science.gov (United States)

    Foster, John E.; Weatherford, Brandon; Gillman, Eric; Yee, Benjamin

    2010-04-01

    A plasma jet produced in water using a submerged ac excited electrode in a coaxial dielectric barrier discharge configuration was studied. Plasma jet formation was found to occur only while the source was submerged. Plasma jet operation was characterized with and without gas flow. It was found that over 60% of the discharge power was deposited into the water and did not vary appreciably with excitation frequency. Presumably the remaining power fraction went into excitation, ionization and local electrode heating. Emission spectra of the jet revealed nitrogen, hydrogen, hydroxyl and oxygen emission lines. Operation of the plasma jet in water containing the oxidation-reduction indicator methylene blue dye resulted in a marked clearing of the water as observed visually and with a spectrophotometer, suggesting plasma-induced chemical reactivity.

  2. Variation of plasma parameters in a modified mode of plasma production in a double plasma device

    Indian Academy of Sciences (India)

    A Phukan; M K Mishra; B K Saikia; M Chakraborty

    2010-03-01

    A modified mode of plasma production in a double plasma device is presented and plasma parameters are controlled in this configuration. Here plasma is produced by applying a discharge voltage between the hot filaments in the source (cathode) and the target magnetic cage (anode) of the device. In this configuration, the hot electron emitting filaments are present only in the source and the magnetic cage of this is kept at a negative bias such that due to the repulsion of the cage bias, the primary electrons can go to the grounded target and produce plasma there. The plasma parameters can be controlled by varying the voltages applied to the source magnetic cage and the separation grid of the device.

  3. Parameter estimation in LISA Pathfinder operational exercises

    CERN Document Server

    Nofrarias, Miquel; Congedo, Giuseppe; Hueller, Mauro; Armano, M; Diaz-Aguilo, M; Grynagier, A; Hewitson, M

    2011-01-01

    The LISA Pathfinder data analysis team has been developing in the last years the infrastructure and methods required to run the mission during flight operations. These are gathered in the LTPDA toolbox, an object oriented MATLAB toolbox that allows all the data analysis functionalities for the mission, while storing the history of all operations performed to the data, thus easing traceability and reproducibility of the analysis. The parameter estimation methods in the toolbox have been applied recently to data sets generated with the OSE (Off-line Simulations Environment), a detailed LISA Pathfinder non-linear simulator that will serve as a reference simulator during mission operations. These operational exercises aim at testing the on-orbit experiments in a realistic environment in terms of software and time constraints. These simulations, so called operational exercises, are the last verification step before translating these experiments into tele-command sequences for the spacecraft, producing therefore ve...

  4. Operational status of the Magnum-PSI linear plasma device

    Energy Technology Data Exchange (ETDEWEB)

    Scholten, John, E-mail: j.scholten@differ.nl; Zeijlmans van Emmichoven, P.A.; Eck, H.J.N. van; Smeets, P.H.M.; De Temmerman, G.C.; Brons, S.; Berg, M.A. van den; Meiden, H.J. van der; Pol, M.J. van de; Graswinckel, M.F.; Groen, P.W.C.; Poelman, A.J.; Genuit, J.W.

    2013-10-15

    Highlights: • High heat flux, high density plasmas in a highly accessible linear plasma device. • Plasma exposure of targets of different sizes under selectable plasma beam angles. • Dedicated plasma and surface diagnostics. • Differential vacuum pumping system. -- Abstract: The construction phase of the linear plasma generator Magnum-PSI at the FOM institute DIFFER has been completed and the facility has been officially opened in March 2012. The scientific program to gain more insight in the plasma–wall interactions relevant for ITER and future fusion reactors has started. In Magnum-PSI, targets of a wide range of materials and shapes can be exposed to high particle, high heat flux plasmas (>10{sup 24} ions m{sup −2} s{sup −1}; >10 MW/m{sup 2}). For magnetization of the plasma, oil-cooled electromagnets are temporarily installed to enable pulsed operation until the device is upgraded with a superconducting magnet. The magnets generate a field of up to 1.9 T close to the plasma source for a duration of 6 s. Longer exposure times are available for lower field settings. Plasma characterizations were done with a variety of gases (H, D, He, Ne and Ar) to determine the machine performance and prepare for subsequent scientific experiments. Thomson scattering and optical emission spectroscopy were used to determine the plasma parameters while infrared thermography and target calorimetry were used to determine the power loads to the surface. This paper reports on the status of Magnum-PSI and its diagnostic systems. In addition, an overview of the plasma parameters that can be achieved in the present state will be given.

  5. Optimum Operational Parameters for Yawed Wind Turbines

    Directory of Open Access Journals (Sweden)

    David A. Peters

    2011-01-01

    Full Text Available A set of systematical optimum operational parameters for wind turbines under various wind directions is derived by using combined momentum-energy and blade-element-energy concepts. The derivations are solved numerically by fixing some parameters at practical values. Then, the interactions between the produced power and the influential factors of it are generated in the figures. It is shown that the maximum power produced is strongly affected by the wind direction, the tip speed, the pitch angle of the rotor, and the drag coefficient, which are specifically indicated by figures. It also turns out that the maximum power can take place at two different optimum tip speeds in some cases. The equations derived herein can also be used in the modeling of tethered wind turbines which can keep aloft and deliver energy.

  6. Progress toward commissioning and plasma operation in NSTX-U

    Science.gov (United States)

    Ono, M.; Chrzanowski, J.; Dudek, L.; Gerhardt, S.; Heitzenroeder, P.; Kaita, R.; Menard, J. E.; Perry, E.; Stevenson, T.; Strykowsky, R.; Titus, P.; von Halle, A.; Williams, M.; Atnafu, N. D.; Blanchard, W.; Cropper, M.; Diallo, A.; Gates, D. A.; Ellis, R.; Erickson, K.; Hosea, J.; Hatcher, R.; Jurczynski, S. Z.; Kaye, S.; Labik, G.; Lawson, J.; LeBlanc, B.; Maingi, R.; Neumeyer, C.; Raman, R.; Raftopoulos, S.; Ramakrishnan, R.; Roquemore, A. L.; Sabbagh, S. A.; Sichta, P.; Schneider, H.; Smith, M.; Stratton, B.; Soukhanovskii, V.; Taylor, G.; Tresemer, K.; Zolfaghari, A.; The NSTX-U Team

    2015-07-01

    The National Spherical Torus Experiment-Upgrade (NSTX-U) is the most powerful spherical torus facility at PPPL, Princeton USA. The major mission of NSTX-U is to develop the physics basis for an ST-based Fusion Nuclear Science Facility (FNSF). The ST-based FNSF has the promise of achieving the high neutron fluence needed for reactor component testing with relatively modest tritium consumption. At the same time, the unique operating regimes of NSTX-U can contribute to several important issues in the physics of burning plasmas to optimize the performance of ITER. NSTX-U further aims to determine the attractiveness of the compact ST for addressing key research needs on the path toward a fusion demonstration power plant (DEMO). The upgrade will nearly double the toroidal magnetic field BT to 1 T at a major radius of R0 = 0.93 m, plasma current Ip to 2 MA and neutral beam injection (NBI) heating power to 14 MW. The anticipated plasma performance enhancement is a quadrupling of the plasma stored energy and near doubling of the plasma confinement time, which would result in a 5-10 fold increase in the fusion performance parameter nτ T. A much more tangential 2nd NBI system, with 2-3 times higher current drive efficiency compared to the 1st NBI system, is installed to attain the 100% non-inductive operation needed for a compact FNSF design. With higher fields and heating powers, the NSTX-U plasma collisionality will be reduced by a factor of 3-6 to help explore the favourable trend in transport towards the low collisionality FNSF regime. The NSTX-U first plasma is planned for the Summer of 2015, at which time the transition to plasma operations will occur.

  7. Dependence of the source performance on plasma parameters at the BATMAN test facility

    Energy Technology Data Exchange (ETDEWEB)

    Wimmer, C.; Fantz, U. [Max-Planck-Institut für Plasmaphysik, Boltzmannstr. 2, 85748 Garching (Germany)

    2015-04-08

    The investigation of the dependence of the source performance (high j{sub H{sup −}}, low j{sub e}) for optimum Cs conditions on the plasma parameters at the BATMAN (Bavarian Test MAchine for Negative hydrogen ions) test facility is desirable in order to find key parameters for the operation of the source as well as to deepen the physical understanding. The most relevant source physics takes place in the extended boundary layer, which is the plasma layer with a thickness of several cm in front of the plasma grid: the production of H{sup −}, its transport through the plasma and its extraction, inevitably accompanied by the co-extraction of electrons. Hence, a link of the source performance with the plasma parameters in the extended boundary layer is expected. In order to characterize electron and negative hydrogen ion fluxes in the extended boundary layer, Cavity Ring-Down Spectroscopy and Langmuir probes have been applied for the measurement of the H{sup −} density and the determination of the plasma density, the plasma potential and the electron temperature, respectively. The plasma potential is of particular importance as it determines the sheath potential profile at the plasma grid: depending on the plasma grid bias relative to the plasma potential, a transition in the plasma sheath from an electron repelling to an electron attracting sheath takes place, influencing strongly the electron fraction of the bias current and thus the amount of co-extracted electrons. Dependencies of the source performance on the determined plasma parameters are presented for the comparison of two source pressures (0.6 Pa, 0.45 Pa) in hydrogen operation. The higher source pressure of 0.6 Pa is a standard point of operation at BATMAN with external magnets, whereas the lower pressure of 0.45 Pa is closer to the ITER requirements (p ≤ 0.3 Pa)

  8. Dependence of the source performance on plasma parameters at the BATMAN test facility

    Science.gov (United States)

    Wimmer, C.; Fantz, U.

    2015-04-01

    The investigation of the dependence of the source performance (high jH-, low je) for optimum Cs conditions on the plasma parameters at the BATMAN (Bavarian Test MAchine for Negative hydrogen ions) test facility is desirable in order to find key parameters for the operation of the source as well as to deepen the physical understanding. The most relevant source physics takes place in the extended boundary layer, which is the plasma layer with a thickness of several cm in front of the plasma grid: the production of H-, its transport through the plasma and its extraction, inevitably accompanied by the co-extraction of electrons. Hence, a link of the source performance with the plasma parameters in the extended boundary layer is expected. In order to characterize electron and negative hydrogen ion fluxes in the extended boundary layer, Cavity Ring-Down Spectroscopy and Langmuir probes have been applied for the measurement of the H- density and the determination of the plasma density, the plasma potential and the electron temperature, respectively. The plasma potential is of particular importance as it determines the sheath potential profile at the plasma grid: depending on the plasma grid bias relative to the plasma potential, a transition in the plasma sheath from an electron repelling to an electron attracting sheath takes place, influencing strongly the electron fraction of the bias current and thus the amount of co-extracted electrons. Dependencies of the source performance on the determined plasma parameters are presented for the comparison of two source pressures (0.6 Pa, 0.45 Pa) in hydrogen operation. The higher source pressure of 0.6 Pa is a standard point of operation at BATMAN with external magnets, whereas the lower pressure of 0.45 Pa is closer to the ITER requirements (p ≤ 0.3 Pa).

  9. A comprehensive study of different gases in inductively coupled plasma torch operating at one atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Punjabi, Sangeeta B. [Electrical Engineering Department, V. J.T.I, Matunga, Mumbai 400019 (India); Department of Physics, University of Mumbai, Kalina, Santacruz(E) 400098 (India); Joshi, N. K. [Faculty of Engineering and technology, MITS, lakshmangarh, (Sikar), Rajasthan 332311 (India); Mangalvedekar, H. A.; Lande, B. K. [Electrical Engineering Department, V. J.T.I, Matunga, Mumbai 400019 (India); Das, A. K. [Laser and Plasma Technology Division, BARC, Mumbai 400085 (India); Kothari, D. C. [Department of Physics, University of Mumbai, Kalina, Santacruz(E) 400098 (India)

    2012-01-15

    A numerical study is done to understand the possible operating regimes of RF-ICP torch (3 MHz, 50 kW) using different gases for plasma formation at atmospheric pressure. A two dimensional numerical simulation of RF-ICP torch using argon, nitrogen, oxygen, and air as plasma gas has been investigated using computational fluid dynamic (CFD) software fluent{sup (c)}. The operating parameters varied here are central gas flow, sheath gas flow, RF-power dissipated in plasma, and plasma gas. The temperature contours, flow field, axial, and radial velocity profiles were investigated under different operating conditions. The plasma resistance, inductance of the torch, and the heat distribution for various plasma gases have also been investigated. The plasma impedance of ICP torch varies with different operating parameters and plays an important role for RF oscillator design and power coupling. These studies will be useful to decide the design criteria for ICP torches required for different material processing applications.

  10. Parameters of atmospheric plasmas produced by electrosurgical devices

    Science.gov (United States)

    Keidar, Michael; Shashurin, Alexey; Canady, Jerome

    2013-10-01

    Electrosurgical systems are extensively utilized in general surgery, surgical oncology, plastic and reconstructive surgery etc. In this work we study plasma parameters created by electrosurgical system SS-200E/Argon 2 of US Medical Innovations. The maximal length of the discharge plasma column at which the discharge can be sustained was determined as function of discharge power and argon flow rate. Electrical parameters including discharge current and voltage were measured. Recently proposed Rayleigh microwave scattering method for temporally resolved density measurements of small-size atmospheric plasmas was utilized. Simultaneously, evolution of plasma column was observed using intensified charge-coupled device (ICCD) camera.

  11. Comparative study of laminar and turbulent flow model with different operating parameters for radio frequency-inductively coupled plasma torch working at 3  MHz frequency at atmospheric pressure

    Energy Technology Data Exchange (ETDEWEB)

    Punjabi, Sangeeta B., E-mail: p.sangeeta@gmail.com [Electrical Engineering Department, V.J.T.I., Matunga, Mumbai 400019 (India); Department of Physics, University of Mumbai, Kalina, Santacruz (E), Mumbai 400098 (India); Sahasrabudhe, S. N.; Das, A. K. [Laser and Plasma Technology Division, BARC, Mumbai 400085 (India); Joshi, N. K. [Faculty of Engineering and Technology, MITS, Lakshmangarh (Sikar), Rajasthan 332311 (India); Mangalvedekar, H. A. [Electrical Engineering Department, V.J.T.I., Matunga, Mumbai 400019 (India); Kothari, D. C. [Department of Physics, University of Mumbai, Kalina, Santacruz (E), Mumbai 400098 (India)

    2014-01-15

    This paper provides 2D comparative study of results obtained using laminar and turbulent flow model for RF (radio frequency) Inductively Coupled Plasma (ICP) torch. The study was done for the RF-ICP torch operating at 50 kW DC power and 3 MHz frequency located at BARC. The numerical modeling for this RF-ICP torch is done using ANSYS software with the developed User Defined Function. A comparative study is done between laminar and turbulent flow model to investigate how temperature and flow fields change when using different operating conditions such as (a) swirl and no swirl velocity for sheath gas flow rate, (b) variation in sheath gas flow rate, and (c) variation in plasma gas flow rate. These studies will be useful for different material processing applications.

  12. Plasma physics analysis of SERT-2 operation

    Science.gov (United States)

    Kaufman, H. R.

    1980-01-01

    An analysis of the major plasma processes involved in the SERT 2 spacecraft experiments was conducted to aid in the interpretation of recent data. A plume penetration model was developed for neutralization electron conduction to the ion beam and showed qualitative agreement with flight data. In the SERT 2 configuration conduction of neutralization electrons between thrusters was experimentally demonstrated in space. The analysis of this configuration suggests that the relative orientation of the two magnetic fields was an important factor in the observed results. Specifically, the opposed field orientation appeared to provide a high conductivity channel between thrusters and a barrier to the ambient low energy electrons in space. The SERT 2 neutralizer currents with negative neutralizer biases were up to about twice the theoretical prediction for electron collection by the ground screen. An explanation for the higher experimental values was a possible conductive path from the neutralizer plume to a nearby part of the ground screen. Plasma probe measurements of SERT 2 gave the clearest indication of plasma electron temperature, with normal operation being near 5 eV and discharge only operation near 2 eV.

  13. Plasma parameters controlled by remote electron shower in a double plasma device

    Science.gov (United States)

    Mishra, M. K.; Phukan, A.

    2012-07-01

    The principal feature of this experiment is the electron showers consisting of three tungsten wires embedded by the plasma, which are heated up consequently emitting electrons inside the diffused plasma to control the plasma parameters in the discharge section of a double plasma device. These cold electrons emitted by the heated filament are free from maintenance of discharge which is sustained in the source section. The target plasma, where electrons are injected is produced as a result of diffusion from the source section. It is found that, plasma density and plasma potential can be effectively controlled in this way.

  14. Collisionless expansion of pulsed radio frequency plasmas. II. Parameter study

    Science.gov (United States)

    Schröder, T.; Grulke, O.; Klinger, T.; Boswell, R. W.; Charles, C.

    2016-01-01

    The plasma parameter dependencies of the dynamics during the expansion of plasma are studied with the use of a versatile particle-in-cell simulation tailored to a plasma expansion experiment [Schröder et al., J. Phys. D: Appl. Phys. 47, 055207 (2014); Schröder et al., Phys. Plasmas 23, 013511 (2016)]. The plasma expansion into a low-density ambient plasma features a propagating ion front that is preceding a density plateau. It has been shown that the front formation is entangled with a wave-breaking mechanism, i.e., an ion collapse [Sack and Schamel, Plasma Phys. Controlled Fusion 27, 717 (1985); Sack and Schamel, Phys. Lett. A 110, 206 (1985)], and the launch of an ion burst [Schröder et al., Phys. Plasmas 23, 013511 (2016)]. The systematic parameter study presented in this paper focuses on the influence on this mechanism its effect on the maximum velocity of the ion front and burst. It is shown that, apart from the well known dependency of the front propagation on the ion sound velocity, it also depends sensitively on the density ratio between main and ambient plasma density. The maximum ion velocity depends further on the initial potential gradient, being mostly influenced by the plasma density ratio in the source and expansion regions. The results of the study are compared with independent numerical studies.

  15. Study on plasma parameters and dust charging in an electrostatically plugged multicusp plasma device

    Science.gov (United States)

    Kakati, B.; Kausik, S. S.; Saikia, B. K.; Bandyopadhyay, M.

    2011-06-01

    The effect of the electrostatic confinement potential on the charging of dust grains and its relationship with the plasma parameters has been studied in an electrostatically plugged multicusp dusty plasma device. Electrostatic plugging is implemented by biasing the electrically isolated magnetic multicusp channel walls. The experimental results show that voltage applied to the channel walls can be a controlling parameter for dust charging.

  16. Effective operator contributions to the oblique parameters

    CERN Document Server

    Sánchez-Colón, G

    1998-01-01

    We present a model and process independent study of the contributions from non-Standard Model physics to the oblique parameters S, T and U. We show that within an effective lagrangian parameterization the expressions for the oblique parameters in terms of observables are consistent, while those in terms of the vector-boson vacuum polarization tensors are ambiguous. We obtain the constraints on the scale of new physics derived from current data on S, T and U and note that deviations in U from its Standard Model value would favor a scenario where the underlying physics does not decouple.

  17. Synthesis of Single Wall Carbon Nanotubes by Plasma Arc: Role of Plasma Parameters

    Science.gov (United States)

    Farhart, Samir; Scott, Carl D.

    2000-01-01

    Single wall carbon nanotubes (SWNT) are porous objects on the molecular scale and have a low density, which gives them potential applications as adsorbent for molecular hydrogen. Their H2 absorption capacity published in the literature varies from 4 to 10% by mass according to the purity of the materials and storage conditions. Optimization of production methods of SWNTs should permit improving these new materials for storage of hydrogen. In this article, we show the potential of using SWNTs in hydrogen storage. In particular, we pose problems associated with synthesis, purification, and opening up of the nanotubes. We present an electric arc process currently used at laboratory scale to produce single wall carbon nanotubes. We discuss, in particular, operating conditions that permit growth of nanotubes and some plasma parameters that assure control of the material. Analysis of the process is carried out with the aid of local measurements of temperature and scanning and transmission electron microscopy of the materials.

  18. Effect of gasification parameter on coal gasification in thermal plasma

    Energy Technology Data Exchange (ETDEWEB)

    Shen, S.; Pang, X.; Bao, W.; Lo, Y.; Zhu, S. [Taiyuan University of Technology, Taiyuan (China)

    2004-12-01

    The influence of several parameters such as the power input of plasma jet, vapor and air input etc on gas composition and carbon conversion from coal gasification in an air-steam plasma jet was studied. The main gaseous products are H{sub 2}, CO, CO{sub 2}, CH{sub 2}4 and tar was discovered. Results show that the concentration of H{sub 2}, CO and carbon conversion increases, and the concentration of CO{sub 2} significantly decreases, when the power input of plasma jet is raised. The concentration of H{sub 2} increases when the vapor flux is increased, but excessive steam can decrease carbon conversion. The carbon conversion is enhanced by decreasing feed rate. The air flux should be reduced to improve the quality of coal gas in a certain range. The carbon conversion of Datong coal can exceed 95% at appropriate condition. 18 refs., 4 figs., 2 tabs.

  19. Programmable physical parameter optimization for particle plasma simulations

    Science.gov (United States)

    Ragan-Kelley, Benjamin; Verboncoeur, John; Lin, Ming-Chieh

    2012-10-01

    We have developed a scheme for interactive and programmable optimization of physical parameters for plasma simulations. The simulation code Object-Oriented Plasma Device 1-D (OOPD1) has been adapted to a Python interface, allowing sophisticated user or program interaction with simulations, and detailed numerical analysis via numpy. Because the analysis/diagnostic interface is the same as the input mechanism (the Python programming language), it is straightforward to optimize simulation parameters based on analysis of previous runs and automate the optimization process using a user-determined scheme and criteria. An example use case of the Child-Langmuir space charge limit in bipolar flow is demonstrated, where the beam current is iterated upon by measuring the relationship of the measured current and the injected current.

  20. Investigation of plasma parameters in an active screen cage-pulsed dc plasma used for plasma nitriding

    Science.gov (United States)

    Naeem, M.; Khattak, Z. I.; Zaka-ul-Islam, M.; Shabir, S.; Khan, A. W.; Zakaullah, M.

    2014-11-01

    Active screen cage-pulsed dc plasmas are widely used in the material processing applications such as plasma nitriding, carburizing and nitrocarburizing. Specifically for plasma nitriding applications, a H2-N2 mixture is used. In this article, a study of the electron number density (ne), atomic nitrogen density ([N]), electron temperature ? and the excitation temperature ? is reported in the presence of an active screen cage-pulsed dc plasma. The ne and ? are determined here by a triple Langmuir probe, while [N] and ? are estimated by optical emission spectroscopy (OES). The two temperatures and their ratio ? are compared for different input parameters (such as applied power, gas pressure and H2 percentage). This study is useful in active screen cage plasma nitriding applications where only few plasma diagnostic measurements have been reported.

  1. Characterisation of Plasma Filled Rod Pinch electron beam diode operation

    Science.gov (United States)

    MacDonald, James; Bland, Simon; Chittenden, Jeremy

    2016-10-01

    The plasma filled rod pinch diode (aka PFRP) offers a small radiographic spot size and a high brightness source. It operates in a very similar to plasma opening switches and dense plasma focus devices - with a plasma prefill, supplied via a number of simple coaxial plasma guns, being snowploughed along a thin rod cathode, before detaching at the end. The aim of this study is to model the PFRP and understand the factors that affect its performance, potentially improving future output. Given the dependence on the PFRP on the prefill, we are making detailed measurements of the density (1015-1018 cm-3), velocity, ionisation and temperature of the plasma emitted from a plasma gun/set of plasma guns. This will then be used to provide initial conditions to the Gorgon 3D MHD code, and the dynamics of the entire rod pinch process studied.

  2. Experimental Results from Initial Operation of Plasma Injector 1

    Science.gov (United States)

    Howard, Stephen

    2010-11-01

    General Fusion has begun operation of its first full-scale plasma injector, designed to accelerate high density spheromak plasmas into the compression chamber of a proposed MTF reactor. The geometry of Plasma Injector 1 (PI-1) is that of a two stage coaxial Marshal gun with a conical converging accelerator electrodes, similar in shape to the MARAUDER device, while pulsed power is applied in the same configuration as the RACE device. PI-1 is 5 meters in length and 1.9 m in diameter at the expansion region where a high aspect ratio (4.4) spheromak is formed with a minimum lambda of 9 m-1. The acceleration/compression stage is 4 m long and tapers to a final outer diameter of 40 cm. PI-1 is now operating at 1 MJ of total capacitor power, which will be doubled again before it reaches its design parameters. Diagnostics include 3 interferometer chords, 21 magnetic probes (2 axis poloidal/toroidal), 13 fast photodiode chords, as well as one Thomson scattering chord, a visible light survey spectrometer, and a Langmuir triple probe. Electrode voltage and current are also monitored. So far spheromaks of poloidal flux exceeding 100 mWb have been formed in the expansion region, and spheromaks of 40-50 mWb have been formed and accelerated out the end of the accelerator into a flux conserving target chamber. Expansion region densities are typically ˜5 x10^14cm-3, while conditions in the target chamber have reached ne˜10^16cm-3, and lifetimes of 300 μs.

  3. Effect of Substrate Potential on Plasma Parameters of Magnetic Multicusp Plasma Source

    Science.gov (United States)

    Ueda, Yoshio; Goto, Masahiro

    1998-06-01

    The effect of substrate potential on plasmas produced in a magnetic multicusp plasma source has been studied experimentally. Plasma parameters such as electron temperature and plasma potential are estimated from electron energy distribution function numerically calculated from probe current-voltage characteristics. For a substrate potential of -150 V with respect to the source chamber, which is much lower than substrate floating potentials, the plasma parameters are not affected by the application of the potential. However, for the case where the substrate is shorted with the source chamber, the high energy component of electrons significantly decreases in comparison with the floating case leading to the reduction of electron temperature. In this case, plasma potential is positive with respect to the substrate to suppress electron loss but its absolute value is only of the order of electron temperature in eV, which is much lower than the potential between the plasma and the substrate in the floating case. This discharge mode could be advantageous in significantly reducing the ion impact energy to the substrate plate.

  4. OPERATION MODES AND CHARACTERISTICS OF PLASMA DIPOLE ANTENNA

    Directory of Open Access Journals (Sweden)

    Nikolay Nikolaevich Bogachev

    2014-02-01

    Full Text Available Existence modes of  surface electromagnetic wave on a plasma cylinder, operating modes and characteristics of the plasma antenna were studied in this paper. Solutions of the dispersion equation of surface wave were obtained for a plasma cylinder with finite radius for different plasma density values. Operation modes of the plasma asymmetric dipole antenna with finite length and radius were researched by numerical simulation. The electric field distributions of  the plasma antenna in near antenna field and the radiation pattern were obtained. These characteristics were compared to characteristics of the similar metal antenna. Numerical models verification was carried out by comparing of the counted and measured metal antenna radiation patterns.

  5. Study on spatial distribution of plasma parameters in a magnetized inductively coupled plasma

    Energy Technology Data Exchange (ETDEWEB)

    Cheong, Hee-Woon; Lee, Woohyun; Kim, Ji-Won; Whang, Ki-Woong, E-mail: kwhang@snu.ac.kr [Plasma Laboratory, Inter-University Semiconductor Research Center, Department of Electrical and Computer Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of); Kim, Hyuk [Samsung Electronics Co., Banwol-dong, Hwaseong 445-701 (Korea, Republic of); Park, Wanjae [Tokyo Electron Miyagi Ltd., Taiwa-cho, Kurokawa-gun, Miyagi 981-3629 (Japan)

    2015-07-15

    Spatial distributions of various plasma parameters such as plasma density, electron temperature, and radical density in an inductively coupled plasma (ICP) and a magnetized inductively coupled plasma (M-ICP) were investigated and compared. Electron temperature in between the rf window and the substrate holder of M-ICP was higher than that of ICP, whereas the one just above the substrate holder of M-ICP was similar to that of ICP when a weak (<8 G) magnetic field was employed. As a result, radical densities in M-ICP were higher than those in ICP and the etch rate of oxide in M-ICP was faster than that in ICP without severe electron charging in 90 nm high aspect ratio contact hole etch.

  6. High-density operation of the Proto-MPEX High Intensity Plasma Source

    Science.gov (United States)

    Caughman, J. B. O.; Goulding, R. H.; Biewer, T. M.; Bigelow, T. S.; Campbell, I. H.; Caneses, J.; Diem, S. J.; Martin, E. H.; Parish, C. M.; Rapp, J.; Ray, H. B.; Shaw, G. C.; Showers, M. A.; Donovan, D.; Piotrowicz, P. A.; Martin, D. C.

    2016-10-01

    The Prototype Materials Plasma Experiment (Proto-MPEX) is a linear high-intensity RF plasma source that combines a high-density helicon plasma generator with ion and electron heating sections. It is being used to study the physics of heating over-dense plasmas in a linear configuration with the goal of delivering a plasma heat flux of 10 MW/m2 at a target. The helicon plasma is produced by coupling 13.56 MHz RF power at levels of >100 kW. A 30 kW ion cyclotron antenna has recently been installed, and microwaves at 28 GHz ( 150 kW) are coupled to the electrons in the over-dense helicon plasma via Electron Bernstein Waves (EBW). High plasma densities near the target have been produced in D ( 5 x1019/m3) , and electron temperatures range from 3 to >10 eV, depending on the source parameters. IR camera images of the target plate indicate plasma heat depositions >10 MW/m2 for some operating conditions. Details of the experimental results of the operational domain with respect to Te and ne as well as results from initial plasma material interaction tests will be presented. ORNL is managed by UT-Battelle, LLC, for the U.S. DOE under contract DE-AC-05-00OR22725.

  7. Plasma Processes : Sheath and plasma parameters in a magnetized plasma system

    Indian Academy of Sciences (India)

    Bornali Singha; A Sharma; J Chutia

    2000-11-01

    The variation of electron temperature and plasma density in a magnetized 2 plasma is studied experimentally in presence of a grid placed at the middle of the system. Plasma leaks through the negatively biased grid from the source region into the diffused region. It is observed that the electron temperature increases with the magnetic field in the diffused region whereas it decreases in the source region of the system for a constant grid biasing voltage. Also, investigation is done to see the change of electron temperature with grid biasing voltage for a constant magnetic field. This is accompanied by the study of the variation of sheath structure across the grid for different magnetic field and grid biasing voltage as well. It reveals that with increasing magnetic field and negative grid biasing voltage, the sheath thickness expands.

  8. A study on plasma parameters in Ar/SF6 inductively coupled plasma

    Science.gov (United States)

    Oh, Seung-Ju; Lee, Hyo-Chang; Chung, Chin-Wook

    2017-01-01

    Sulfur hexafluoride (SF6) gas or Ar/SF6 mixing gas is widely used in plasma processes. However, there are a little experimental studies with various external parameters such as gas pressure and mixing ratio. In this work, a study of the plasma parameters by changing the gas mixing ratio was done in an Ar/SF6 inductively coupled plasma from the measurement of the electron energy distribution function. At a low gas pressure, as the mixing ratio of SF6 gas increased at a fixed inductively coupled plasma (ICP) power, the electron density decreased and the electron temperature increased, while they were not changed drastically. At a high gas pressure, a remarkable increase in the electron temperature was observed with the decrease in the electron density. These variations are due to the electron loss reactions such as the electron attachment. It was also found that at a fixed ICP power, the negative ion creation with the diluted SF6 gas can change the discharge mode transition from an inductive mode to a capacitive mode at the high gas pressure. The electron attachment reactions remove the low energy electrons and change the mean electron energy towards higher energies with diluting SF6 gas at high pressure. The measured results were compared with the simplified global model, and the global model is in relatively good agreement with the measured plasma parameters except for the result in the case of the large portion of SF6 gas at the high pressure and the capacitive mode, which causes strong negative ion formation by the electron attachment reactions.

  9. Evolution of plasma parameters in a He - N2/Ar magnetic pole enhanced inductive plasma source

    Science.gov (United States)

    Younus, Maria; Rehman, N. U.; Shafiq, M.; Zakaullah, M.; Abrar, M.

    2016-02-01

    A magnetic pole enhanced inductively coupled H e - N2/A r plasma is studied at low pressure, to monitor the effects of helium mixing on plasma parameters like electron number density (ne) , electron temperature (Te) , plasma potential (Vp ) , and electron energy probability functions (EEPFs). An RF compensated Langmuir probe is employed to measure these plasma parameters. It is noted that electron number density increases with increasing RF power and helium concentration in the mixture, while it decreases with increase in filling gas pressure. On the other hand, electron temperature shows an increasing trend with helium concentration in the mixture. At low RF powers and low helium concentration in the mixture, EEPFs show a "bi-Maxwellian" distribution with pressure. While at RF powers greater than 50 W and higher helium concentration in the mixture, EEPFs evolve into "Maxwellian" distribution. The variation of skin depth with RF power and helium concentration in the mixture, and its relation with EEPF are also studied. The effect of helium concentrations on the temperatures of two electron groups ( Tb u l k and Tt a i l ) in the "bi-Maxwellian" EEPFs is also observed. The temperature of low energy electron group ( Tb u l k) shows significant increase with helium addition, while the temperature of tail electrons ( Tt a i l) increases smoothly as compared to ( Tb u l k).

  10. Automatic measurements of plasma parameters in the PUPR mirror and cusp plasma machine

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, S; Colmenares, F; Gonzalez-Lizardo, A; Leal-Quiros, E [Plasma Engineering Laboratory, Polytechnic University of Puerto Rico, San Juan, PR 00918 (Puerto Rico)

    2008-10-15

    This paper presents an ongoing effort to develop an automatic measurement system for plasma diagnostics at the Plasma Engineering Laboratory of the Polytechnic University of Puerto Rico (PUPR), along with an example of its operation. The system is intended to be used with electrostatic probes such as single and double Langmuir probes, emissive probes, ion and electron energy analyzers, etc. The automatic measurement system includes automatic positioning of the probes inside the plasma chamber, automatic voltage sweep of the probes for each position, and automatic analysis of the probe I-V characteristic. The results of measurements obtained by using this automatic measurement system during a particular experiment are shown and compared with a traditional method with satisfactory results.

  11. Ignitor Plasma Physics Performance in the H-Regime at Various Parameters

    Science.gov (United States)

    Detragiache, P.; Coppi, B.

    2010-11-01

    The plasma physics performance of Ignitor at full (BT = 13 T, Ip = 10 MA) as well as at reduced parameters (BT = 8 T, Ip = 5 MA) in the high confinement mode (H-regime) is assessed using global 0-D modelling. At full parameters, high-Q operation is possible if the heating power (a combination of Ohmic, α and limited ICRF power) is above the threshold value Pthr for H-regime confinement. Different scaling expressions for Pthr yield significantly different results when used with Ignitor parameters. Even with the most pessimistic among the proposed scalingsootnotetextY. R. Martin et al., Journal of Physics: Conference Series, 123, 012033 (2008). the access to H-regime confinement is possible for Ignitor at full field when the ICRH system is operated at the highest frequency and the generated power is less than at lower frequencies. At reduced parameters, the lower Pthr and the augmented ICRF power available (about 10 MW) facilitate access to H-regime confinement, while the plasma performance remains respectable.

  12. Use of a probing pulsed magnetic field for determining plasma parameters

    Science.gov (United States)

    Rousskikh, A. G.; Oreshkin, V. I.; Zhigalin, A. S.; Yushkov, G. Yu.

    2016-11-01

    A novel, simple, and readily usable method is proposed for measuring the electrical conductivity and temperature of a plasma. The method is based on the interaction of the test plasma with a pulsed magnetic field. The electric signals induced by the magnetic field in the circuits of two probes (miniature solenoids), one immersed in the test plasma and the other placed outside the plasma, provide data for estimating the plasma parameters. The method was verified experimentally by determining the parameters of the plasma flows generated in the cathode spots high-current pulsed vacuum arcs that were used to form cylindrical shells of bismuth Z-pinch plasma.

  13. Tuning the operational parameters of the first microtron stage

    Science.gov (United States)

    Jahnke, Cristiane; Silva, Tiago F.; Martins, Marcos N.

    2013-05-01

    The Laboratório do Acelerador Linear is building a racetrack microtron electron accelerator. It has two acceleration stages: the booster and the main microtron. The aim of this work is to optimize the operation parameters of the booster stage by means of simulation tools. The accelerator admittances were determined successfuly and the results are presented. The injection beam has been characterized previously, and the available data were used to match the transverse beam emittances of the injector to the transverse beam admittances of the booster. Preliminary results showed that the simulations have a good agreement with the working parameters.

  14. Tuning the operational parameters of the first microtron stage

    Energy Technology Data Exchange (ETDEWEB)

    Jahnke, Cristiane; Silva, Tiago F.; Martins, Marcos N. [Instituto de Fisica da Universidade de Sao Paulo, C.P. 66318, 05315-970 Sao Paulo, SP (Brazil)

    2013-05-06

    The Laboratorio do Acelerador Linear is building a racetrack microtron electron accelerator. It has two acceleration stages: the booster and the main microtron. The aim of this work is to optimize the operation parameters of the booster stage by means of simulation tools. The accelerator admittances were determined successfuly and the results are presented. The injection beam has been characterized previously, and the available data were used to match the transverse beam emittances of the injector to the transverse beam admittances of the booster. Preliminary results showed that the simulations have a good agreement with the working parameters.

  15. Revisiting linear plasma waves for finite value of the plasma parameter

    Science.gov (United States)

    Grismayer, Thomas; Fahlen, Jay; Decyk, Viktor; Mori, Warren

    2010-11-01

    We investigate through theory and PIC simulations the Landau-damping of plasma waves with finite plasma parameter. We concentrate on the linear regime, γφB, where the waves are typically small and below the thermal noise. We simulate these condition using 1,2,3D electrostatic PIC codes (BEPS), noting that modern computers now allow us to simulate cases where (nλD^3 = [1e2;1e6]). We study these waves by using a subtraction technique in which two simulations are carried out. In the first, a small wave is initialized or driven, in the second no wave is excited. The results are subtracted to provide a clean signal that can be studied. As nλD^3 is decreased, the number of resonant electrons can be small for linear waves. We show how the damping changes as a result of having few resonant particles. We also find that for small nλD^3 fluctuations can cause the electrons to undergo collisions that eventually destroy the initial wave. A quantity of interest is the the life time of a particular mode which depends on the plasma parameter and the wave number. The life time is estimated and then compared with the numerical results. A surprising result is that even for large values of nλD^3 some non-Vlasov discreteness effects appear to be important.

  16. The optimization of operating parameters on microalgae upscaling process planning.

    Science.gov (United States)

    Ma, Yu-An; Huang, Hsin-Fu; Yu, Chung-Chyi

    2016-03-01

    The upscaling process planning developed in this study primarily involved optimizing operating parameters, i.e., dilution ratios, during process designs. Minimal variable cost was used as an indicator for selecting the optimal combination of dilution ratios. The upper and lower mean confidence intervals obtained from the actual cultured cell density data were used as the final cell density stability indicator after the operating parameters or dilution ratios were selected. The process planning method and results were demonstrated through three case studies of batch culture simulation. They are (1) final objective cell densities were adjusted, (2) high and low light intensities were used for intermediate-scale cultures, and (3) the number of culture days was expressed as integers for the intermediate-scale culture.

  17. WIND TURBINE OPERATION PARAMETER CHARACTERISTICS AT A GIVEN WIND SPEED

    Directory of Open Access Journals (Sweden)

    Zdzisław Kamiński

    2014-06-01

    Full Text Available This paper discusses the results of the CFD simulation of the flow around Vertical Axis Wind Turbine rotor. The examined rotor was designed following patent application no. 402214. The turbine operation is characterised by parameters, such as opening angle of blades, power, torque, rotational velocity at a given wind velocity. Those parameters have an impact on the performance of entire assembly. The distribution of forces acting on the working surfaces in the turbine can change, depending on the angle of rotor rotation. Moreover, the resultant force derived from the force acting on the oncoming and leaving blades should be as high as possible. Accordingly, those parameters were individually simulated over time for each blade in three complete rotations. The attempts to improve the performance of the entire system resulted in a new research trend to improve the performance of working turbine rotor blades.

  18. The effect of thermophoresis on the discharge parameters in complex plasma experiments

    CERN Document Server

    Land, Victor; Creel, James; Schmoke, Jimmy; Cook, Mike; Matthews, Lorin; Hyde, Truell

    2010-01-01

    Thermophoresis is a tool often applied in complex plasma experiments. One of the usual stated benefits over other experimental tools is that changes induced by thermophoresis neither directly depend on, nor directly influence, the plasma parameters. From electronic data, plasma emission profiles in the sheath, and Langmuir probe data in the plasma bulk, we conclude that this assumption does not hold. An important effect on the levitation of dust particles in argon plasma is observed as well. The reason behind the changes in plasma parameters seems to be the change in neutral atom density accompanying the increased gas temperature while running at constant pressure.

  19. The effect of electrode heating on the discharge parameters in complex plasma experiments

    Energy Technology Data Exchange (ETDEWEB)

    Land, Victor; Carmona-Reyes, Jorge; Creel, James; Schmoke, Jimmy; Cook, Mike; Matthews, Lorin; Hyde, Truell, E-mail: victor_land@baylor.edu [Center for Astrophysics, Space Physics, and Engineering Research, Baylor University, Waco, TX, 76798-7316 (United States)

    2011-02-15

    Thermophoresis is a tool often applied in complex plasma experiments. One of the usual stated benefits over other experimental tools is that electrode temperature changes required to induce thermophoresis do not directly influence the plasma parameters. From electronic data, plasma emission profiles in the sheath, and Langmuir probe data in the plasma bulk, we conclude that this assumption does not hold. An important effect on the levitation of dust particles in argon plasma is observed as well. The reason behind the changes in plasma parameters seems to be the change in neutral atom density accompanying the increased gas temperature while running at constant pressure.

  20. Nonlinear Optical Parameters of Magnetoactive Semiconductor-Plasmas

    Science.gov (United States)

    Singh, M.; Joseph, D.; Duhan, S.

    The nonlinear optical parameters (absorption coefficient and refractive index) of semiconductor-plasmas subjected to a transverse magnetic field have been investigated analytically. By employing the coupled-mode scheme, an expression of third-order optical susceptibility and resultant nonlinear absorption and refractive index of the medium are obtained. The analysis has been applied to both cases, viz., centrosymmetric (β = 0) and noncentrosymmetric (β ≠ 0) in the presence of magnetic field. The numerical estimates are made for InSb crystal at liquid nitrogen temperature duly irradiated by a 10-nanosecond pulsed 10.6 μm CO2 laser. The influence of doping concentration and magnetic field on both the nonlinear absorption and refractive index has been explored, and the results are found to be well in agreement with theory and experiment. Analysis further establishes that absorption coefficient and refractive index can be controlled with precision in semiconductors by the proper selection of doping concentration and an external magnetic field, and hence these media may be used for fabrication of fast cubic nonlinear optical devices under off-resonant transition regime.

  1. Technical information report: Plasma melter operation, reliability, and maintenance analysis

    Energy Technology Data Exchange (ETDEWEB)

    Hendrickson, D.W. [ed.

    1995-03-14

    This document provides a technical report of operability, reliability, and maintenance of a plasma melter for low-level waste vitrification, in support of the Hanford Tank Waste Remediation System (TWRS) Low-Level Waste (LLW) Vitrification Program. A process description is provided that minimizes maintenance and downtime and includes material and energy balances, equipment sizes and arrangement, startup/operation/maintence/shutdown cycle descriptions, and basis for scale-up to a 200 metric ton/day production facility. Operational requirements are provided including utilities, feeds, labor, and maintenance. Equipment reliability estimates and maintenance requirements are provided which includes a list of failure modes, responses, and consequences.

  2. Influence analysis of structural parameters and operating parameters on electromagnetic properties of HTS linear induction motor

    Science.gov (United States)

    Fang, J.; Sheng, L.; Li, D.; Zhao, J.; Li, Sh.; Qin, W.; Fan, Y.; Zheng, Q. L.; Zhang, W.

    A novel High Temperature Superconductor Linear Induction Motor (HTS LIM) is researched in this paper. Since the critical current and the electromagnetic force of the motor are determined mainly by the primary slot leakage flux, the main magnetic flux and eddy current respectively, in order to research the influence of structural parameters and operating parameters on electromagnetic properties of HTS LIM, the motor was analyzed by 2D transient Finite Element Method (FEM). The properties of the motor, such as the maximum slot leakage flux density, motor thrust, motor vertical force and critical current are analyzed with different structural parameters and operating parameters. In addition, an experimental investigation was carried out on prototype HTS motor. Electrical parameters were deduced from these tests and also compared with the analysis results from FEM. AC losses of one HTS coil in the motor were measured and AC losses of all HTS coils in HTS LIM were estimated. The results in this paper could provide reference for the design and research on the HTS LIM.

  3. Investigation of the effects of electron plasma frequency on the operation of a helix TWT

    Science.gov (United States)

    Oksuz, Lutfi; Haytural, Necati; Uygun, Emre; Bozduman, Ferhat; Yesiltepe, Hakan; Gulec, Ali

    2016-10-01

    The oscillations of electrons are an important subject for the design procedure of linear beam tubes such as klystrons and TWTs. These oscillation frequencies may be affected by the finite region of the tube if the plasma wavelength of the electrons are larger than the bounding region of the device, leading to a reduced plasma frequency which further leads to an increase in wavelength. Following the Pierce's theory on traveling wave tubes, it is seen that the reduced plasma frequency takes place in space charge terms which also include the Pierce's gain parameter C. In this study the effects of plasma frequency on the operation of a helix TWT are investigated using CST Particle Studio. This project is supported by TUBITAK with project number: 1140075.

  4. Flux Decline in Protein Microfiltration: Influence of Operative Parameters

    Science.gov (United States)

    Herrero; Pradanos; Calvo; Tejerina; Hernandez

    1997-03-15

    The flux decline, is studied in typical experiments with dead-end microfiltration of BSA solutions (1, 3, 5 and 10 g/L) through Cyclopore track-etched polycarbonate membranes (nominal pore size 0.1 μm) at several pH values and two ionic strengths. Results have been analyzed in terms of the common blocking laws and correlated with the operation parameters. Variations of pressure, concentration, pH, and ionic strength have shown great influence on the kinetics of protein deposition. In any case, the process of membrane fouling can be divided in two steps, clearly separated in all the experiments: a rapid initial internal blocking, strongly dependent on operation parameters, and a final stage of external blocking with lower sensitivity of the flux behavior on operation conditions. Finally, the amount of adsorbed protein and its influence on pore size distribution have been analyzed by desorption with a SDS-solution and by an extended bubble point method. These results show that the initial internal pore blocking can be attributed to protein adsorption while the long-time fouling should be caused mainly by solute-solute interactions.

  5. Spectroscopic studies of the parameters of plasma jets during their propagation in the background plasma on the PF-3 facility

    Science.gov (United States)

    Dan’ko, S. A.; Ananyev, S. S.; Kalinin, Yu G.; Krauz, V. I.; Myalton, V. V.

    2017-04-01

    This paper presents measurement results of neon and helium plasma parameters in axial jets generated in plasma focus discharge. They were obtained in the course of experiments on laboratory modeling of astrophysical jets performed at the PF-3 facility. The plasma concentration was determined according to Stark broadening of spectral lines; the ionization temperature was determined by the average ion charge. The values of the concentration and temperature of jet plasma and background plasma at two distances from the pinch are also presented. In addition, an estimation was made of the heat content losses of the neon and helium jets during their movement through the surrounding medium.

  6. Optimization of Process Parameters of Tool Wear in Turning Operation

    Directory of Open Access Journals (Sweden)

    Manik Barman

    2015-04-01

    Full Text Available Tool Wear is of great apprehension in machining industries since itaffects the surface quality, dimensional accuracy and production cost of the materials / components. In the present study twenty seven experiments were conducted as per 3 parameter 3 level full factorial design for turning operation of a mild steel specimen with high speed steel (HSS cutting tool. An experimental investigation on cutting tool wear and a mathematical model for tool wear estimation is reported in this paper where the model was simulated by computer programming and it has been found that this model is capable of estimating the wear rate of cutting tool and it provides an optimum set of process parameters for minimum tool wear.

  7. Optimal line drop compensation parameters under multi-operating conditions

    Science.gov (United States)

    Wan, Yuan; Li, Hang; Wang, Kai; He, Zhe

    2017-01-01

    Line Drop Compensation (LDC) is a main function of Reactive Current Compensation (RCC) which is developed to improve voltage stability. While LDC has benefit to voltage, it may deteriorate the small-disturbance rotor angle stability of power system. In present paper, an intelligent algorithm which is combined by Genetic Algorithm (GA) and Backpropagation Neural Network (BPNN) is proposed to optimize parameters of LDC. The objective function proposed in present paper takes consideration of voltage deviation and power system oscillation minimal damping ratio under multi-operating conditions. A simulation based on middle area of Jiangxi province power system is used to demonstrate the intelligent algorithm. The optimization result shows that coordinate optimized parameters can meet the multioperating conditions requirement and improve voltage stability as much as possible while guaranteeing enough damping ratio.

  8. Parameters influencing plasma column potential in a reflex discharge

    Science.gov (United States)

    Liziakin, G. D.; Gavrikov, A. V.; Murzaev, Y. A.; Usmanov, R. A.; Smirnov, V. P.

    2016-12-01

    Distribution of electrostatic potential in direct current reflex discharge plasma has been studied experimentally. Measurements have been conducted by the single floating probe method. The influence of 0-0.2 T magnetic field, 1-200 mTorr pressure, 0-2 kV discharge voltage, and electrodes geometry on plasma column electrostatic potential was investigated. The possibility for the formation of a preset potential profile required for the realization of plasma separation of spent nuclear fuel was demonstrated.

  9. Study of Operating Parameters for Accelerated Anode Degradation in SOFCs

    DEFF Research Database (Denmark)

    Ploner, Alexandra; Hagen, Anke; Hauch, Anne

    2017-01-01

    Solid oxide fuel cell (SOFC) applications require lifetimes of several years on the system level. A big challenge is to demonstrate such exceptionally long lifetimes in ongoing R&D projects. Accelerated or compressed testing are alternative methods to obtain this. Activities in this area have been...... carried out without arriving at a generally accepted methodology. This is mainly due to the complexity of degradation mechanisms on the single SOFC components as function of operating parameters. In this study, we present a detailed analysis of approx. 180 durability tests regarding degradation of single...... SOFC components as function of operating conditions. Electrochemical impedance data were collected on the fresh and long-term tested SOFCs and used to de-convolute the individual losses of single SOFC cell components – electrolyte, cathode and anode. The main findings include a time-dependent effect...

  10. Biliopancreatic diversion with duodenal switch modifies plasma chemerin in early and late post-operative periods.

    Science.gov (United States)

    Parlee, Sebastian D; Wang, Yan; Poirier, Paul; Lapointe, Marc; Martin, Julie; Bastien, Marjorie; Cianflone, Katherine; Goralski, Kerry B

    2015-06-01

    Bariatric surgery remains the most effective treatment for obesity and metabolic syndrome. Surgical benefit arises from early-phase resolution of hyperglycemia and late-phase weight loss. The adipokine chemerin is of interest given its roles in immunity, adipogenesis, and metabolism. The study objective was to examine the effects of biliopancreatic diversion with duodenal switch (BPD-DS) on plasma chemerin in the early and late post-operative stages. 83 adults with obesity undergoing BPD-DS, 45 obese non-surgical controls, and 9 lean surgical controls were enrolled. Plasma parameters and anthropometric measures were obtained at baseline and at, early (24 h, 5 D) and late (6 months and 12 months) post-operative stages. Plasma chemerin dropped from 176±49 ng/mL at baseline to 132±52 ng/mL 24 h after BPD-DS, rebounded to 200±66 ng/mL after 5 D, and declined to 124±51 and 110±34 ng/mL after 6 and 12 months. Plasma chemerin correlated negatively with measures of inflammation and hepatic injury and positively with measures of obesity, metabolic syndrome, and inflammation in the early and late post-operative periods, respectively. Chemerin has a novel role in surgical injury but not hyperglycemia resolution early after BPD-DS. Over the long term, plasma chemerin declines to a new set point that is partially determined by body fat reductions. © 2015 The Obesity Society.

  11. Multi-parameter gradient procedure for polarimetry data inversion in tokamak plasma

    Energy Technology Data Exchange (ETDEWEB)

    Chrzanowski, J., E-mail: j.chrzanowski@am.szczecin.pl [Maritime University, Szczecin Wały Chrobrego 1/2 (Poland); Kravtsov, Yu. A. [Maritime University, Szczecin Wały Chrobrego 1/2 (Poland); Mazon, D. [Association Euratom/CEA, CEA Cadarache DSM/IRFM, 13108 St. Paul lez Durance Cedex (France); JET, Culham (United Kingdom)

    2013-10-15

    Highlights: ► We use gradient procedure to fit plasma parameters to polarimetric data. ► Calculations are performed in developed by authors angular variables technique. ► Numerical results are compared with experimentally measured angular parameters. ► We observe satisfied accuracy of inversion procedure after several iterations. -- Abstract: Multi-parameter gradient procedure is suggested which allows fitting tokamak plasma model to polarimetric data. One of the simplest version of gradient procedure deals with four parameters model: maximum values of electron density, maximum value of electric current density in plasma, common radius of electron density, electric current distributions and increment of the safety factor inside plasma. Using recently developed by authors angular variables technique (AVT) in plasma polarimetry we may compute angular parameters of polarization ellipse for a given set of four plasma parameters and compare them with experimentally measured angular parameters. With angular parameters, measured in two channels polarimetric system (two azimuthal and two ellipticity angles, totally four experimental values). Applying then gradient procedure for squared difference between computed and measured parameters, we find four parameters of plasma model and thereby perform inversion of polarimetric data. Numerical simulations have approved that gradient procedure provides acceptable accuracy of inversion already after several iterations.

  12. Geographic and Operational Site Parameters List (GOSPL) for Hanford Assessments

    Energy Technology Data Exchange (ETDEWEB)

    Last, George V.; Nichols, William E.; Kincaid, Charles T.

    2006-06-01

    This data package was originally prepared to support a 2004 composite analysis (CA) of low-level waste disposal at the Hanford Site. The Technical Scope and Approach for the 2004 Composite Analysis of Low Level Waste Disposal at the Hanford Site (Kincaid et. al. 2004) identified the requirements for that analysis and served as the basis for initial preparation of this data package. Completion of the 2004 CA was later deferred, with the 2004 Annual Status Report for the Composite Analysis of Low-Level Waste Disposal in the Central Plateau at the Hanford Site (DOE 2005) indicating that a comprehensive update to the CA was in preparation and would be submitted in 2006. However, the U.S. Department of Energy (DOE) has recently decided to further defer the CA update and will use the cumulative assessment currently under preparation for the environmental impact statement (EIS) being prepared for tank closure and other site decisions as the updated CA. Submittal of the draft EIS is currently planned for FY 2008. This data package describes the facility-specific parameters (e.g. location, operational dates, etc.) used to numerically simulate contaminant flow and transport in large-scale Hanford assessments. Kincaid et al. (2004) indicated that the System Assessment Capability (SAC) (Kincaid et al. 2000; Bryce et al. 2002; Eslinger 2002a, 2002b) would be used to analyze over a thousand different waste sites. A master spreadsheet termed the Geographic and Operational Site Parameters List (GOSPL) was assembled to facilitate the generation of keyword input files containing general information on each waste site/facility, its operational/disposal history, and its environmental settings (past, current, and future). This report briefly describes each of the key data fields, including the source(s) of data, and provides the resulting inputs to be used for large-scale Hanford assessments.

  13. Computing an operating parameter of a unified power flow controller

    Science.gov (United States)

    Wilson, David G; Robinett, III, Rush D

    2015-01-06

    A Unified Power Flow Controller described herein comprises a sensor that outputs at least one sensed condition, a processor that receives the at least one sensed condition, a memory that comprises control logic that is executable by the processor; and power electronics that comprise power storage, wherein the processor causes the power electronics to selectively cause the power storage to act as one of a power generator or a load based at least in part upon the at least one sensed condition output by the sensor and the control logic, and wherein at least one operating parameter of the power electronics is designed to facilitate maximal transmittal of electrical power generated at a variable power generation system to a grid system while meeting power constraints set forth by the electrical power grid.

  14. A method of extracting operating parameters of a quantum circuit

    Science.gov (United States)

    Sete, Eyob A.; Block, Maxwell; Scheer, Michael; Zanoci, Cris; Vahidpour, Mehrnoosh; Thompson, Dane; Rigetti, Chad

    Rigorous simulation-driven design methods are an essential component of traditional integrated circuit design. We adapt these techniques to the design and development of superconducting quantum integrated circuits by combining classical finite element analysis in the microwave domain with Brune circuit synthesis by Solgun [PhD thesis 2014] and BKD Hamiltonian analysis by Burkard et al. [Phys. Rev. B 69, 064503 (2004)]. Using the Hamiltonian of the quantum circuit, constructed using the synthesized equivalent linear circuit and the nonlinear Josephson junctions' contributions, we extract operating parameters of the quantum circuit such as resonance coupling strength, dispersive shift, qubit anharmonicitiy, and decoherence rates for single-and multi-port quantum circuits. This approach has been experimentally validated and allows the closed-loop iterative simulation-driven development of quantum information processing devices.

  15. Integral electrical characteristics and local plasma parameters of a RF ion thruster

    Energy Technology Data Exchange (ETDEWEB)

    Masherov, P. E.; Riaby, V. A., E-mail: riaby2001@yahoo.com [Research Institute of Applied Mechanics and Electrodynamics of the Moscow Aviation Institute (National Research University), Moscow (Russian Federation); Godyak, V. A. [Electrical Engineering and Computer Science Department, University of Michigan, Ann Arbor, Michigan 48109, USA and RF Plasma Consulting, Brookline, Massachusetts 02446 (United States)

    2016-02-15

    Comprehensive diagnostics has been carried out for a RF ion thruster based on inductively coupled plasma (ICP) source with an external flat antenna coil enhanced by ferrite core. The ICP was confined within a cylindrical chamber with low aspect ratio to minimize plasma loss to the chamber wall. Integral diagnostics of the ICP electrical parameters (RF power balance and coil current) allowed for evaluation of the antenna coils, matching networks, and eddy current loss and the true RF power deposited to plasma. Spatially resolved electron energy distribution functions, plasma density, electron temperatures, and plasma potentials were measured with movable Langmuir probes.

  16. Plasma Arc Cutting Dimensional Accuracy Optimization employing the Parameter Design approach

    Directory of Open Access Journals (Sweden)

    Kechagias John

    2017-01-01

    Full Text Available Plasma Arc Cutting (PAC is a thermal manufacturing process used for metal plates cutting. This work experimentally investigates the influence of process parameters onto the dimensional accuracy performance of the plasma arc cutting process. The cutting parameters studied were cutting speed (mm/min, torch standoff distance (mm, and arc voltage (volts. Linear dimensions of a rectangular workpiece were measured after PAC cutting following the full factorial design experimental approach. For each one of the three process parameters, three parameter levels were used. Analysis of means (ANOM and analysis of variances (ANOVA were performed in order for the effect of each parameter on the leaner dimensional accuracy to be assessed.

  17. Increasing plasma parameters using sheared flow stabilization of a Z-pinch

    Science.gov (United States)

    Shumlak, U.; Nelson, B. A.; Claveau, E. L.; Forbes, E. G.; Golingo, R. P.; Hughes, M. C.; Oberto, R. J.; Ross, M. P.; Weber, T. R.

    2017-05-01

    The ZaP and ZaP-HD Flow Z-pinch experiments at the University of Washington have successfully demonstrated that sheared plasma flows can be used as a stabilization mechanism over a range of parameters that has not previously been accessible to long-lived Z-pinch configurations. The stabilization is effective even when the plasma column is compressed to small radii, producing predicted increases in magnetic field and electron temperature. The flow shear value, extent, and duration are shown to be consistent with theoretical models of the plasma viscosity, which places a design constraint on the maximum axial length of a sheared flow stabilized Z-pinch. Measurements of the magnetic field topology indicate simultaneous azimuthal symmetry and axial uniformity along the entire 100 cm length of the Z-pinch plasma. Separate control of plasma acceleration and compression has increased the accessible plasma parameters and has generated stable plasmas with radii of 0.3 cm, as measured with a high resolution digital holographic interferometer. Compressing the plasma with higher pinch currents has produced high magnetic fields (8.5 T) and electron temperatures (1 keV) with an electron density of 2 ×1017 cm-3, while maintaining plasma stability for many Alfvén times (approximately 50 μs). The results suggest that sheared flow stabilization can be applied to extend Z-pinch plasma parameters to high energy densities.

  18. Statistical analysis of the operating parameters which affect cupola emissions

    Energy Technology Data Exchange (ETDEWEB)

    Davis, J.W.; Draper, A.B.

    1977-12-01

    A sampling program was undertaken to determine the operating parameters which affected air pollution emission from gray iron foundry cupolas. The experimental design utilized the analysis of variance routine. Four independent variables were selected for examination on the basis of previous work reported in the literature. These were: (1) blast rate; (2) iron-coke ratio; (3) blast temperature; and (4) cupola size. The last variable was chosen since it most directly affects melt rate. Emissions from cupolas for which concern has been expressed are particle matter and carbon monoxide. The dependent variables were, therefore, particle loading, particle size distribution, and carbon monoxide concentration. Seven production foundries were visited and samples taken under conditions prescribed by the experimental plan. The data obtained from these tests were analyzed using the analysis of variance and other statistical techniques where applicable. The results indicated that blast rate, blast temperature, and cupola size affected particle emissions and the latter two also affected the particle size distribution. The particle size information was also unique in that it showed a consistent particle size distribution at all seven foundaries with a sizable fraction of the particles less than 1.0 micrometers in diameter.

  19. Langmuir probe Diagnostic for local parameter measurement in Magnetized Plasma using LabVIEW

    Directory of Open Access Journals (Sweden)

    Bijal Vara

    2014-03-01

    Full Text Available In recent years, plasma technology is used by Semiconductor, thin film industries for deposit layers, etching process and surface modification. So it is necessary to understanding internal plasma parameter. Langmuir probe is one of the simplest techniques which is used to measure wide range of plasma parameter like plasma potential, floating potential, electron temperature, electron energy distribution function (EEDF etc. Langmuir current voltage characteristic is obtained by varying bias voltage of the probe. LabVIEW is most powerful Microsoft window compatible software which is used to immediate data acquisition and analysis. In this paper describes analysis of Langmuir data using LabVIEW software which automatically measure I-V Plasma probe Characteristics and obtain EEDF of plasma.

  20. Determination of Some Biochemical Parameters in the Seminal Plasma of German Shepherd Dogs

    OpenAIRE

    GÜNAY, Ülgen

    2003-01-01

    In this study, we aimed to determine the levels of some biochemical parameters in the seminal plasma of German Shepherd dogs. Seven German Shepherd dogs were used as materials. A total of 35 ejaculates, five from each dog, were collected. The seminal plasma of each ejaculate was separated by centrifugation at 5000 rpm for 10 min. Biochemical analyses of the seminal plasma were performed. In conclusion, the average concentrations of total protein, calcium, phosphorus, magnesium, sodium and pot...

  1. Scaling Factor of the Operating Parameters of Z-pinch Liners

    Institute of Scientific and Technical Information of China (English)

    曾正中; 邱孟通; 蒯斌; 邱爱慈

    2002-01-01

    Imploding plasma liners in the Z-pinch scheme have been demonstrated to be capable of producing high power radiation in the soft X-ray waveband owing to the conversion of the kinetic energy of imploding liner into thermal energy which in turn is converted into X-ray energy. To obtain largest X-ray power for a certain pulsed-power driving- source, the liner should gain a kinetic energy as great as possible, which imposes an optimal scaling upon the operating parameters of liner in terms of getting largest kinetic energy. This work exposes, by means of numerical calculations based on zero-dimensional quasi-plasma-shell model, the large variation of the scaling factor, which connects the parameters of the initial liner and the driving current, with different driving current waveforms. Also solved in the work is the optimal scaling factor in the sense of producing maximum kinetic energy. Calculations show that maximum kinetic energy is obtained at the current maximum or a little time later. These results are in reasonable agreement with several experiments and will be of help to the design and experimental adjustment of Z-pinch liners.

  2. EFFECT OF PLASMA CUTTING PARAMETERS UPON SHAPES OF BEARING CURVE OF C45 STEEL SURFACE

    Directory of Open Access Journals (Sweden)

    Agnieszka Skoczylas

    2015-08-01

    Full Text Available The article presents the results of studies on the effect of plasma cutting technological parameters upon the shape of bearing curves and the parameters of the curve. The topography of surface formed by plasma cutting were analyzed. For measuring surface roughness and determining the bearing curve the appliance T8000 RC120 – 400 by Hommel-Etamic was used together with software.

  3. ISS And Space Environment Interactions Without Operating Plasma Contactor

    Science.gov (United States)

    Carruth, M. R., Jr.; Ferguson, Dale; Suggs,Rob; McCollum, Matt

    2001-01-01

    The International Space Station (ISS) will be the largest, highest power spacecraft placed in orbit. Because of this the design of the electrical power system diverged markedly from previous systems. The solar arrays will operate at 160 V and the power distribution voltage will be 120 V. The structure is grounded to the negative side of the solar arrays so under the right circumstances it is possible to drive the ISS potential very negative. A plasma contactor has been added to the ISS to provide control of the ISS structure potential relative to the ambient plasma. The ISS requirement is that the ISS structure not be greater than 40 V positive or negative of local plasma. What are the ramifications of operating large structures with such high voltage power systems? The application of a plasma contactor on ISS controls the potential between the structure and the local plasma, preventing degrading effects. It is conceivable that there can be situations where the plasma contactor might be non-functional. This might be due to lack of power, the need to turn it off during some of the build-up sequences, the loss of functionality for both plasma contactors before a replacement can be installed, similar circumstances. A study was undertaken to understand how important it is to have the contactor functioning and how long it might be off before unacceptable degradation to ISS could occur. The details of interaction effects on spacecraft have not been addressed until driven by design. This was true for ISS. If the structure is allowed to float highly negative impinging ions can sputter exposed conductors which can degrade the primary surface and also generate contamination due to the sputtered material. Arcing has been known to occur on solar arrays that float negative of the ambient plasma. This can also generate electromagnetic interference and voltage transients. Much of the ISS structure and pressure module surfaces exposed to space is anodized aluminum. The anodization

  4. Alteration of Lysophosphatidylcholine-Related Metabolic Parameters in the Plasma of Mice with Experimental Sepsis.

    Science.gov (United States)

    Ahn, Won-Gyun; Jung, Jun-Sub; Kwon, Hyeok Yil; Song, Dong-Keun

    2017-04-01

    Plasma concentration of lysophosphatidylcholine (LPC) was reported to decrease in patients with sepsis. However, the mechanisms of sepsis-induced decrease in plasma LPC levels are not currently well known. In mice subjected to cecal ligation and puncture (CLP), a model of polymicrobial peritoneal sepsis, we examined alterations in LPC-related metabolic parameters in plasma, i.e., the plasma concentration of LPC-related substances (i.e., phosphatidylcholine (PC) and lysophosphatidic acid (LPA)), and activities or levels in the plasma of some enzymes that can be involved in the regulation of plasma LPC concentration (i.e., secretory phospholipase A2 (sPLA2), lecithin:cholesterol acyltransferase (LCAT), acyl-CoA:lysophosphatidylcholine acyltransferase (LPCAT), and autotaxin (ATX)), as well as plasma albumin concentration. We found that levels of LPC and albumin and enzyme activities of LCAT, ATX, and sPLA2 were decreased, whereas levels of PC, LPA, and LPCAT1-3 were increased in the plasma of mice subjected to CLP. Bacterial peritonitis led to alterations in all the measured LPC-related metabolic parameters in the plasma, which could potentially contribute to sepsis-induced decrease in plasma LPC levels. These findings could lead to the novel biomarkers of sepsis.

  5. Analysis of the operating parameters of a vortex electrostatic precipitator

    Science.gov (United States)

    Congxiang, Lu; Chengwu, Yi; Rongjie, Yi; Shiwen, Liu

    2017-02-01

    A vortex electrostatic precipitator (VEP) forms a vortex flow field within a precipitator by means of the vertical staggered layout of the double-vortex collecting plate facing the direction of the gas flow. The ion concentrations within the precipitator can be significantly increased. Correspondingly, the charging and coagulation rates of fine particles and particle migration velocity are significantly improved within the VEP. Since it can effectively collect fine particles and reduce precipitator size, VEPs represent a new type of electrostatic precipitator with great application potential. In this work the change curve of the external voltage, gas velocity, row spacing and effective collecting area influencing the precipitation efficiency were acquired through a single-factor experiment. Using an orthogonal regression design, attempts were made to analyze the major operating parameters influencing the collecting efficiency of fine particles, establish a multiple linear regression model and analyze the weights of factors and then acquire quantitative rules relating experimental indicators and factors. The regression model was optimized by MATLAB programming, and we then obtained the optimal factor combination which can enhance the efficiency of fine particle collection. The final optimized result is that: when gas velocity is 3.4 m s-1, the external voltage is 18 kV, row spacing is 100 mm and the effective collecting area is 1.13 m2, the rate of fine particle collection is 89.8867%. After determining and analyzing the state of the internal flow field within the VEP by particle image velocimetry (PIV), the results show that, for a particular gas velocity, a vortex zone and laminar zone are distinctly formed within the VEP, which increases the ion transport ratio as well as the charging, coagulation and collection rates of fine particles within the precipitator, thus making further improvements in the efficiency of fine particle collection.

  6. Analysis of the operating parameters of a vortex electrostatic precipitator

    Science.gov (United States)

    Lu, Congxiang; Yi, Chengwu; Yi, Rongjie; Liu, Shiwen

    2017-02-01

    A vortex electrostatic precipitator (VEP) forms a vortex flow field within a precipitator by means of the vertical staggered layout of the double-vortex collecting plate facing the direction of the gas flow. The ion concentrations within the precipitator can be significantly increased. Correspondingly, the charging and coagulation rates of fine particles and particle migration velocity are significantly improved within the VEP. Since it can effectively collect fine particles and reduce precipitator size, VEPs represent a new type of electrostatic precipitator with great application potential. In this work the change curve of the external voltage, gas velocity, row spacing and effective collecting area influencing the precipitation efficiency were acquired through a single-factor experiment. Using an orthogonal regression design, attempts were made to analyze the major operating parameters influencing the collecting efficiency of fine particles, establish a multiple linear regression model and analyze the weights of factors and then acquire quantitative rules relating experimental indicators and factors. The regression model was optimized by MATLAB programming, and we then obtained the optimal factor combination which can enhance the efficiency of fine particle collection. The final optimized result is that: when gas velocity is 3.4 m s-1, the external voltage is 18 kV, row spacing is 100 mm and the effective collecting area is 1.13 m2, the rate of fine particle collection is 89.8867%. After determining and analyzing the state of the internal flow field within the VEP by particle image velocimetry (PIV), the results show that, for a particular gas velocity, a vortex zone and laminar zone are distinctly formed within the VEP, which increases the ion transport ratio as well as the charging, coagulation and collection rates of fine particles within the precipitator, thus making further improvements in the efficiency of fine particle collection.

  7. Online tuning of impedance matching circuit for long pulse inductively coupled plasma source operation--an alternate approach.

    Science.gov (United States)

    Sudhir, Dass; Bandyopadhyay, M; Kraus, W; Gahlaut, A; Bansal, G; Chakraborty, A

    2014-01-01

    Impedance matching circuit between radio frequency (RF) generator and the plasma load, placed between them, determines the RF power transfer from RF generator to the plasma load. The impedance of plasma load depends on the plasma parameters through skin depth and plasma conductivity or resistivity. Therefore, for long pulse operation of inductively coupled plasmas, particularly for high power (∼100 kW or more) where plasma load condition may vary due to different reasons (e.g., pressure, power, and thermal), online tuning of impedance matching circuit is necessary through feedback. In fusion grade ion source operation, such online methodology through feedback is not present but offline remote tuning by adjusting the matching circuit capacitors and tuning the driving frequency of the RF generator between the ion source operation pulses is envisaged. The present model is an approach for remote impedance tuning methodology for long pulse operation and corresponding online impedance matching algorithm based on RF coil antenna current measurement or coil antenna calorimetric measurement may be useful in this regard.

  8. Analyses of plasma parameter profiles in JT-60U

    Energy Technology Data Exchange (ETDEWEB)

    Shirai, Hiroshi; Shimizu, Katsuhiro; Hayashi, Nobuhiko [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment; Itakura, Hirofumi; Takase, Keizou [CSK Co. Ltd., Tokyo (Japan)

    2001-01-01

    The methods how diagnostics data are treated as the surface quantity of magnetic surface and processed to the profile data in the JT-60U plasmas are summarized. The MHD equilibrium obtained by solving Grad-Shafranov equation on the MHD equilibrium calculation and registration software FBEQU are saved shot by shot as a database. Various experimental plasma data measured at various geometrical positions on JT-60 are mapped onto the MHD equilibrium and treated as functions of the volume averaged minor radius {rho} on the experimental data time slice monitoring software SLICE. Experimental data are integrated and edited on SLICE. The experimental data measured as the line integral values are transformed by Able inversion. The mapped data are fitted to a functional form and saved to the profile database MAP-DB. SLICE can also read data from MAP-DB and redisplay and transform them. In addition, SLICE can generate the profile data TOKRD as run data for orbit following Monte-Carlo (OFMC) code, analyzer for current drive consistent with MHD equilibrium (ACCOME) code and tokamak predictive and interpretive code system (TOPICS). (author)

  9. Clinical and Prognostic Significance of Preoperative Plasma Fibrinogen Levels in Patients with Operable Breast Cancer.

    Directory of Open Access Journals (Sweden)

    Yu Mei

    Full Text Available Elevated plasma fibrinogen levels are associated with tumor progression and poor outcomes in different cancer patients. The objective of this study was to investigate the clinical and prognostic value of preoperative plasma fibrinogen levels in patients with operable breast cancer.Two hundred and twenty-three patients diagnosed with breast cancer were retrospectively evaluated in this study. Plasma fibrinogen levels were examined before treatment and analyzed along with patient clinicopathological parameters, disease-free survival (DFS and overall survival (OS. Both univariate and multivariate analyses were performed to identify the clinicopathological parameters associated with DFS and OS.Elevated preoperative plasma fibrinogen levels were directly associated with age of diagnose (≤47 vs. >47, p<0.001, menopause (yes vs. no, p<0.001, tumor size (T1&T2 vs. T3&T4, p = 0.033, tumor stage (I vs. II vs. III, p = 0.034 and lymph node involvement (N = 0 vs. 1≤N≤3 vs. N≥4, p<0.001, but not with histological grade, molecular type and other Immunohistochemical parameters (ER, PR, HER2 and Ki-67. In a univariate survival analysis, tumor stage, tumor size, lymph node involvement (p<0.001/p<0.001 and plasma fibrinogen (p<0.001/p<0.001 levels were associated with disease-free and overall survival, but just lymph nodes involvement (p<0.001, hazard ratio [HR] = 2.9, 95% confidence interval [CI] = 1.6-5.3/p = 0.006, HR = 3.2, 95% CI = 1.4-7.3 and plasma fibrinogen levels (p = 0.006, HR = 3.4, 95% CI = 1.4-8.3/p = 0.002, HR = 10.1, 95% CI = 2.3-44.6 were associated with disease-free and overall survival in a multivariate survival analysis, respectively.This study demonstrates that elevated preoperative plasma fibrinogen levels are associated with breast cancer progression and are independently associated with a poor prognosis in patients with operable breast cancer.

  10. OTF CCSDS Mission Operations Prototype Parameter Service. Phase I: Exit Presentation

    Science.gov (United States)

    Reynolds, Walter F.; Lucord, Steven A.; Stevens, John E.

    2009-01-01

    This slide presentation reviews the prototype of phase 1 of the parameter service design of the CCSDS mission operations. The project goals are to: (1) Demonstrate the use of Mission Operations standards to implement the Parameter Service (2) Demonstrate interoperability between Houston MCC and a CCSDS Mission Operations compliant mission operations center (3) Utilize Mission Operations Common Architecture. THe parameter service design, interfaces, and structures are described.

  11. Trace formulas for parameter-dependent pseudodifferential operators

    DEFF Research Database (Denmark)

    Grubb, Gerd

    2002-01-01

    Trace expansions for operator families such as the resolvent, the heat operator and the complex powers are established for elliptic problems containing pseudodifferential elements. We consider operators on closed manifolds, as well as operators on compact manifolds with boundary, where suitable b...... boundary conditions must be added. It is found in general that one can obtain expansions, e.g. of the heat operator trace, in powers ta and power-logarithmic terms ta log t, and the stability of the coefficients under perturbations is discussed. A survey is given of the methods relying...

  12. Downstream plasma parameters in laminar shocks from ion kinetics

    Science.gov (United States)

    Gedalin, M.

    2016-10-01

    Ion dynamics in oblique shocks is governed by the macroscopic electric and magnetic fields of the shock front. In laminar shocks, these fields are time-independent and depend only on the coordinate along the shock normal. The shock ramp is narrow and the ion motion across the shock is manifestly non-adiabatic. The ion distribution just behind the ramp is significantly non-gyrotropic. Gyrotropy is achieved well behind the ramp mainly due to the gyrophase mixing. The asymptotic values of the ion density and temperature are determined by the eventual collisionless relaxation of the gyrating ion distribution. Given a distribution at the downstream edge of the ramp, the moments of the distribution after gyrophase mixing are derived using proper spatial averaging. The obtained expressions can be used for independent determination of the downstream plasma state and implementation in Rankine-Hugoniot relations.

  13. Influence of direct current plasma magnetron sputtering parameters on the material characteristics of polycrystalline copper films

    Energy Technology Data Exchange (ETDEWEB)

    Chan, K.-Y. [Thin Film Laboratory, Faculty of Engineering, Multimedia University, Jalan Multimedia, 63100 Cyberjaya, Selangor (Malaysia)], E-mail: k.y.chan@fz-juelich.de; Luo, P.-Q.; Zhou, Z.-B. [Department of Physics, Shanghai Jiao Tong University, 800 Dongchuan Road, 200240 Shanghai (China); Tou, T.-Y.; Teo, B.-S. [Thin Film Laboratory, Faculty of Engineering, Multimedia University, Jalan Multimedia, 63100 Cyberjaya, Selangor (Malaysia)

    2009-03-01

    Physical vapor processes using glow plasma discharge are widely employed in microelectronic industry. In particular magnetron sputtering is a major technique employed for the coating of thin films. This paper addresses the influence of direct current (DC) plasma magnetron sputtering parameters on the material characteristics of polycrystalline copper (Cu) thin films coated on silicon substrates. The influence of the sputtering parameters including DC plasma power and argon working gas pressure on the electrical and structural properties of the thin Cu films was investigated by means of surface profilometer, four-point probe and atomic force microscopy.

  14. Profiles of ion beams and plasma parameters on a multi-frequencies microwaves large bore electron cyclotron resonance ion source with permanent magnets.

    Science.gov (United States)

    Kato, Yushi; Sakamoto, Naoki; Kiriyama, Ryutaro; Takenaka, Tomoya; Kurisu, Yosuke; Nozaki, Dai; Sato, Fuminobu; Iida, Toshiyuki

    2012-02-01

    In order to contribute to various applications of plasma and beams based on an electron cyclotron resonance, a new concept on magnetic field with all magnets on plasma production and confinement has been proposed with enhanced efficiency for broad and dense ion beam. The magnetic field configuration consists of a pair of comb-shaped magnet surrounding plasma chamber cylindrically. Resonance zones corresponding for 2.45 GHz and 11-13 GHz frequencies are positioned at spatially different positions. We launch simultaneously multiplex frequencies microwaves operated individually, try to control profiles of the plasma parameters and the extracted ion beams, and to measure them in detail.

  15. Cryogenic pellet production developments for long-pulse plasma operation

    Energy Technology Data Exchange (ETDEWEB)

    Meitner, S. J.; Baylor, L. R.; Combs, S. K.; Fehling, D. T.; McGill, J. M.; Duckworth, R. C.; McGinnis, W. D.; Rasmussen, D. A. [Oak Ridge National Laboratory, 1Bethel Valley Rd Oak Ridge, TN 37831 (United States)

    2014-01-29

    Long pulse plasma operation on large magnetic fusion devices require multiple forms of cryogenically formed pellets for plasma fueling, on-demand edge localized mode (ELM) triggering, radiative cooling of the divertor, and impurity transport studies. The solid deuterium fueling and ELM triggering pellets can be formed by extrusions created by helium cooled, twin-screw extruder based injection system that freezes deuterium in the screw section. A solenoid actuated cutter mechanism is activated to cut the pellets from the extrusion, inserting them into the barrel, and then fired by the pneumatic valve pulse of high pressure gas. Fuel pellets are injected at a rate up to 10 Hz, and ELM triggering pellets are injected at rates up to 20 Hz. The radiative cooling and impurity transport study pellets are produced by introducing impurity gas into a helium cooled section of a pipe gun where it deposits in-situ. A pneumatic valve is opened and propellant gas is released downstream where it encounters a passive punch which initially accelerates the pellet before the gas flow around the finishes the pellet acceleration. This paper discusses the various cryogenic pellet production techniques based on the twin-screw extruder, pipe gun, and pellet punch designs.

  16. Seminal plasma zinc level may be associated with the effect of cigarette smoking on sperm parameters.

    Science.gov (United States)

    Liu, R-Z; Gao, J-C; Zhang, H-G; Wang, R-X; Zhang, Z-H; Liu, X-Y

    2010-01-01

    The aim of this study was to investigate the effect of cigarette smoking on seminal plasma zinc levels and sperm parameters, and to examine the role of seminal plasma zinc. Semen samples from 79 non-smokers and 68 smokers were obtained. There was a significant decrease in seminal plasma zinc in smokers and a clear correlation between seminal plasma zinc levels and the extent of smoking. Sperm parameters (concentration, motility and morphology) among smokers were significantly lower in comparison to non-smokers. These parameters were also significantly decreased among smokers with abnormal zinc levels, while there was no significant difference between non-smokers with normal zinc and non-smokers with abnormal zinc levels. As previous studies have shown that seminal plasma zinc is associated with a decrease of anti-oxidant defences, seminal plasma zinc could be a contributor to the effects of cigarette smoking on sperm parameters. In conclusion, cigarette smoking can affect sperm parameters and this study may help towards providing a mechanistic explanation.

  17. The Lexicon-Syntax Parameter: reflexivization and other arity operations

    NARCIS (Netherlands)

    Reinhart, A.; Siloni, T.

    2006-01-01

    The specific problem we address in this study is what explains the coherent cross-linguistic variation in the array of reflexive verbs. We show that a single parameter straightforwardly derives the variation. In addition, the parameter turns out to be responsible for parallel variations in other emp

  18. Success parameters for housing co-operatives in South Africa

    Directory of Open Access Journals (Sweden)

    Jimoh Richard

    2012-12-01

    Full Text Available The roles of the various governments have been the driving force of the housing co-operatives in those countries due to the tremendous support received. The implication is that the housing co-operatives in any country cannot do it alone without the support of government in areas such as having legislation and policies, providing support services and embarking on regular education and training. The need to explore the housing co-operatives in South Africa with a view to determine the successes recorded over the years becomes imperative in order to advance strategies that will ensure virile and sustainable housing co-operatives. Results revealed that a lack of understanding exists as a result of inadequate information among government officials responsible for housing delivery and the public in the application of co-operative housing as a delivery approach. Also, inadequate training of co-operative members in leadership positions lead to a lack of administrative and management capabilities in the processes and operations of housing co-operatives. A pragmatic approach should be adopted so that legislation and policies that are beneficial to the housing co-operatives be enacted.

  19. Optimization of nitrogen plasma source parameters by measurements of emitted light intensity for growth of GaN by molecular beam epitaxy

    Energy Technology Data Exchange (ETDEWEB)

    Klosek, K.; Sobanska, M.; Tchutchulashvili, G.; Zytkiewicz, Z.R., E-mail: zytkie@ifpan.edu.pl; Teisseyre, H.; Klopotowski, L.

    2013-05-01

    A comprehensive analysis of operating parameters of Addon RF nitrogen plasma source was made in order to determine how a ratio of different active nitrogen species depends on operating parameters of the source such as supplied power and nitrogen flow. We show that output signal of the optical sensor that measures intensity of the light emitted by the plasma is a direct measure of the amount of active nitrogen available for growth. Results of optical emission spectroscopy and measurements of growth kinetics show that nitrogen excited metastable molecules are the species mainly contributing to the growth of GaN under Ga-rich conditions. A procedure is presented allowing to find an optimal conditions of the plasma cell for high-quality GaN growth. Under these conditions the nitrogen flux contains maximum amount of excited metastable molecules and minimal amount of ionic and atomic nitrogen species to minimize GaN lattice damage, even at high growth rates. - Highlights: ► Operating parameters of Addon radio-frequency nitrogen plasma source studied ► Their influence on molecular beam epitaxy (MBE) growth of GaN analyzed ► MBE growth rate of GaN well correlates with output of the plasma emission sensor. ► Optical emission spectroscopy measurements of the nitrogen plasma made ► Nitrogen excited molecules mainly contribute to plasma-assisted MBE growth of GaN.

  20. Parameter-dependent Pseudodifferential Operators of Toeplitz Type on Closed Manifolds

    CERN Document Server

    Seiler, Jörg

    2012-01-01

    We present a calculus of zero-order parameter-dependent pseudodifferential operators on a closed manifold $M$ that contains both usual parameter-dependent operators - where the parameter enters as an additional covariable - as well as operators independent of the parameter. Parameter-ellipticity is characterized by the invertibility of three associated principal symbols. In case of ellipticity we can construct a parametrix that is an inverse for large values of the parameter. We then extend this parametrix-construction to operators of Toeplitz type, in particular, to operators of the form $P_1A(\\tau)P_0$ where both $P_0$ and $P_1$ are zero-order projections and $A(\\tau)$ is a usual parameter-dependent operator of arbitrary order or $A(\\tau)=\\tau^{\\mu}-A$ with a pseudodifferential operator $A$ of positiv order $\\mu\\in\

  1. DBD plasma source operated in single-filamentary mode for therapeutic use in dermatology

    Science.gov (United States)

    Rajasekaran, Priyadarshini; Mertmann, Philipp; Bibinov, Nikita; Wandke, Dirk; Viöl, Wolfgang; Awakowicz, Peter

    2009-11-01

    Our dielectric barrier discharge (DBD) plasma source for bio-medical application comprises a copper electrode covered with ceramic. Objects of high capacitance such as the human body can be used as the opposite electrode. In this study, the DBD source is operated in single-filamentary mode using an aluminium spike as the opposite electrode, to imitate the conditions when the discharge is ignited on a raised point, such as hair, during therapeutic use on the human body. The single-filamentary discharge thus obtained is characterized using optical emission spectroscopy, numerical simulation, voltage-current measurements and microphotography. For characterization of the discharge, averaged plasma parameters such as electron distribution function and electron density are determined. Fluxes of nitric oxide (NO), ozone (O3) and photons reaching the treated surface are simulated. The calculated fluxes are finally compared with corresponding fluxes used in different bio-medical applications.

  2. Methodology for Evaluating Safety System Operability using Virtual Parameter Network

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sukyoung; Heo, Gyunyoung [Kyung Hee Univ., Yongin (Korea, Republic of); Kim, Jung Taek [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Tae Wan [Kepco International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2014-05-15

    KAERI (Korea Atomic Energy Research Institute) and UTK (University of Tennessee Knoxville) are working on the I-NERI project to suggest complement of this problem. This research propose the methodology which provide the alternative signal in case of unable guaranteed reliability of some instrumentation with KAERI. Proposed methodology is assumed that several instrumentations are working normally under the power supply condition because we do not consider the instrumentation survivability itself. Thus, concept of the Virtual Parameter Network (VPN) is used to identify the associations between plant parameters. This paper is extended version of the paper which was submitted last KNS meeting by changing the methodology and adding the result of the case study. In previous research, we used Artificial Neural Network (ANN) inferential technique for estimation model but every time this model showed different estimate value due to random bias each time. Therefore Auto-Associative Kernel Regression (AAKR) model which have same number of inputs and outputs is used to estimate. Also the importance measures in the previous method depend on estimation model but importance measure of improved method independent on estimation model. Also importance index of previous method depended on estimation model but importance index of improved method is independent on estimation model. In this study, we proposed the methodology to identify the internal state of power plant when severe accident happens also it has been validated through case study. SBLOCA which has large contribution to severe accident is considered as initiating event and relationship amongst parameter has been identified. VPN has ability to identify that which parameter has to be observed and which parameter can be alternative to the missing parameter when some instruments are failed in severe accident. In this study we have identified through results that commonly number 2, 3, 4 parameter has high connectivity while

  3. Analytical estimation of particle shape formation parameters in a plasma-chemical reactor

    Directory of Open Access Journals (Sweden)

    Zhukov Ilya A.

    2017-01-01

    Full Text Available Analytical estimation of particle shape formation parameters in a plasma-chemical reactor implementing the process of thermochemical decomposition of liquid droplet agents (precursors in the flow of a high-temperature gaseous heat-transfer medium was obtained. The basic factor which determines the process is the increase of concentration of a dissolved salt precursor component at the surface of a liquid particle due to solvent evaporation. According to the physical concept of the method of integral balance the diffusion process of concentration change is divided into two stages: the first stage is when the size of gradient layer does not reach the center of a spherical droplet and the second stage when the concentration at the center of a liquid droplet begins to change. The solutions for concentration fields were found for each stage using the method of integral balance taking into account the formation of salt precipitate when the concentration at the surface of the droplet reaches certain equilibrium value. The results of estimation of the influence of various reactor operation parameters and characteristics of initial solution (precursor on the morphology of particles formed – mass fraction and localization of salt precipitate for various levels of evaporation.

  4. Effects of cigarette smoking on hemorheologic parameters, plasma osmolality and lung function.

    Science.gov (United States)

    Ergun, Dilek Duzgun; Karis, Denizhan; Alkan, Fatma Ates; Cakmak, Gulfidan; Yenigun, Mustafa; Ercan, Meltem

    2016-10-05

    Cigarette smoking deteriorates human health via vascular disorders, cancer and especially respiratory diseases. The aim of this study is to investigate effects of cigarette smoking on hemorheologic parameters, plasma osmolality and lung function in individuals without diagnosis of chronic obstructive pulmonary disease (COPD). Patients diagnosed without COPD utilizing respiratory function test were enrolled in the study with three groups, ex-smokers (n = 21), current-smokers (n = 35) and never-smokers (n = 43). Hemorheologic parameters and plasma osmolality were measured in hemorheology laboratory. SPSS 17.0 was used for statistical analysis. Blood and plasma viscosity, fibrinogen and hematocrit levels, mean corpuscular volume and mean corpuscular hemoglobin concentration were significantly elevated in ex-smokers and current-smokers compared to never-smokers. The standardized red blood cell deformability and oxygen delivery index and lung function were statistically lower in current-smokers than never-smokers. Pulmonary blood flow rate was statistically lower in current-smokers and ex-smokers than never-smokers. Plasma osmolality was statistically significantly higher in ex-smokers and current-smokers than never-smokers. Our findings clearly show that cigarette smoking has severe effects on hemorheologic parameters, plasma osmolality and lung function even in individuals without COPD. Blood and plasma viscosity with plasma osmolality might be useful markers to detect early hemorheologic-hemodynamic alterations in cigarette smokers.

  5. Nanofocus: an ultra-miniature dense pinch plasma focus device with submillimetric anode operating at 0.1 J

    Energy Technology Data Exchange (ETDEWEB)

    Soto, Leopoldo; Pavez, Cristian; Moreno, Jose [Comision Chilena de Energia Nuclear, Casilla 188-D, Santiago (Chile); Barbaglia, Mario; Clausse, Alejandro [CNEA-CONICET and Universidad Nacional del Centro, 7000 Tandil (Argentina)], E-mail: lsoto@cchen.cl

    2009-02-01

    As a method for investigating the minimum energy to produce a pinch plasma focus (PF) discharge, an ultra-miniature device for pinch discharges has been designed, constructed and characterized (nanofocus (NF): 5 nF, 5-10 kV, 5-10 kA, 60-250 mJ, 16 ns time to peak current). Submillimetric anode radii (0.8 and 0.21 mm) covered by coaxial insulators were used for experiments in hydrogen. Evidence of pinch was observed in electrical signals in discharges operating at 3 mbar and {approx}100 mJ. A single-frame image converter camera (4 ns exposure) was used to obtain plasma images in the visible range. The dynamics observed from the photographs is consistent with (a) the formation of a plasma sheath close to the insulator surface, (b) the plasma covering the anode, (c) radial compression over the anode; (d) finally the plasma is detached from the anode in the axial direction. The total time from stages (a) to (d) was observed in {approx}30 ns. This ultra-miniature device has a value for the 'plasma energy density parameter' and for the 'drive parameter' of the same order or greater than PF devices operating at energies several orders of magnitude higher.

  6. Correlation of operating parameters on turbine shaft vibrations

    Science.gov (United States)

    Dixit, Harsh Kumar; Rajora, Rajeev

    2016-05-01

    The new generation of condition monitoring and diagnostics system plays an important role in efficient functioning of power plants. In most of the rotating machine, defects can be detected by such a system much before dangerous situation occurs. It allows the efficient use of stationary on-line continuous monitoring system for condition monitoring and diagnostics as well. Condition monitoring of turbine shaft can not only reduce expenses of maintenance of turbo generator of power plants but also prevents likely shutdown of plant, thereby increases plant load factor. Turbo visionary parameters are essential part of health diagnosis system of turbo generator. Particularly steam pressure, steam temperature and lube oil temperature are important parameters to monitor because they are having much influence on turbine shaft vibration and also governing systems are available for change values of those parameters. This paper includes influence of turbo visionary parameters i.e., steam temperature, steam pressure, lube oil temperature, turbine speed and load on turbine shaft vibration at turbo generator at 195 MW unit-6,Kota Super Thermal Power Station by measuring vibration amplitude and analyze them in MATLAB.

  7. Real time measurement of plasma macroscopic parameters on RFX-mod using a limited set of sensors

    Science.gov (United States)

    Kudlacek, Ondrej; Zanca, Paolo; Finotti, Claudio; Marchiori, Giuseppe; Cavazzana, Roberto; Marrelli, Lionello

    2015-10-01

    A method to estimate the plasma boundary and global parameters such as βp+li/2 and the edge safety factor q95 is described. The method is based on poloidal flux extrapolation in the vacuum region between the plasma and the magnetic measurements, and it is efficient and accurate even if a limited set of sensors is used. The discrepancy between the plasma boundary provided by this method and the boundary computed by the Grad-Shafranov solver MAXFEA is lower than 8 mm in all the considered cases. Moreover, the method is robust against the noise level present in the RFX-mod measurements. The difference between the estimated global parameters and the MAXFEA simulation results is lower than 4%. The method was finally implemented in the RFX-mod shape control system, working at 5 kHz cycle frequency, to provide a reliable set of plasma-wall distances (gaps) used as feedback signals. Experimental results obtained in one year of RFX-mod operation are shown.

  8. Effect of magnetic barrier on the plasma parameters in a Trimix-M galatea

    Science.gov (United States)

    Morozov, A. I.; Bugrova, A. I.; Bishaev, A. M.; Lipatov, A. S.; Kozintseva, M. V.

    2006-11-01

    The parameters of plasma trapped in a Trimix-M galatea with increased values of the magnetic barrier and the energy of a hydrogen plasma bunch injected in the trap have been determined. For a barrier magnetic field of B b ˜ 0.1 T, the plasma confinement time in the trap is τp ≈ 300 μs (which agrees with estimates obtained using formulas describing the classical transfer), the maximum electron density is n e ˜ 5 × 1013 cm-3, and the electron and ion temperatures are T e ≈ 20 eV and T i ˜ 2T e, respectively. The energy of trapped plasma is ˜110 J, and the ratio of the gaskinetic to magnetic pressure in the plasma is β0 ˜ 0.2.

  9. Impact of plasma parameter on self-organization of electron temperature gradient driven turbulence

    Science.gov (United States)

    Kawai, C.; Idomura, Y.; Maeyama, S.; Ogawa, Y.

    2017-04-01

    Self-organization in the slab electron temperature gradient driven (ETG) turbulence is investigated based on gyrokinetic simulations and the Hasegawa-Mima (HM) equation. The scale and the anisotropy of self-organized turbulent structures vary depending on the Rhines scale and the characteristic scale given by the adiabatic response term in the HM equation. The former is determined by competition between the linear wave dispersion and the nonlinear turbulent cascade, while the latter is given as the scale, at which the turbulent cascade is impeded. These scales are controlled by plasma parameters such as the density and temperature gradient, and the temperature ratio of ion to electron. It is found that depending on the plasma parameters, the ETG turbulence shows either isotropic turbulence or zonal flows, which give significantly different transport levels. Although the modulational instability excites zonal modes regardless of the plasma parameters, the final turbulent structure is determined by the self-organization process.

  10. Variation of plasma parameters of vacuum arc column with gap distance

    Science.gov (United States)

    Han, Wen; Yuan, Zhao; He, Junjia

    2016-07-01

    On the basis of a two-dimensional (2D) magneto-hydrodynamic model, we studied long-gap-distance vacuum arcs in a uniform axial magnetic field and determined the effect of gap distance varying in a large range on plasma parameters. Simulation results showed that with increasing gap distance, the parameters of the plasma near the cathode are almost invariant, except for ion number density, but the parameters of the plasma in front of the anode clearly vary; meanwhile, joule heat gradually becomes the main source of energy for the arc column. In a short gap, a clear current constriction can be found in the entire arc column. Whereas when the gap distance exceeds a certain value, a sharp contraction of the current only arises in front of the anode.

  11. Optimization of operational aircraft parameters Reducing Noise Emission

    CERN Document Server

    Abdallah, Lina; Khardi, Salah

    2008-01-01

    The objective of this paper is to develop a model and a minimization method to provide flight path optimums reducing aircraft noise in the vicinity of airports. Optimization algorithm has solved a complex optimal control problem, and generates flight paths minimizing aircraft noise levels. Operational and safety constraints have been considered and their limits satisfied. Results are here presented and discussed.

  12. Internal oscillating current-sustained RF plasmas: Parameters, stability, and potential for surface engineering

    DEFF Research Database (Denmark)

    Ostrikov, K.; Tsakadze, E.L.; Tsakadze, Z.L.;

    2005-01-01

    plasma parameters by the optical and Langmuir probes are presented. It is shown that the spatial profiles of the electron density, the effective electron temperature and plasma potential feature a great deal of the radial and axial uniformity compared with conventional sources of inductively coupled......A new source of low-frequency (0.46 MHz) inductively coupled plasmas sustained by the internal planar "unidirectional" RF current driven through a specially designed internal antenna configuration has been developed. The experimental results of the investigation of the optical and global argon...... applications and surface engineering. (c) 2005 Elsevier B.V. All rights reserved....

  13. The technology and science of steady-state operation in magnetically confined plasmas

    Science.gov (United States)

    Bécoulet, A.; Hoang, G. T.

    2008-12-01

    fusion device. The first includes specific additional heating and current drive methods (through externally launched radio-frequency waves or energetic atoms), fuelling and pumping methods, dedicated plasma diagnostics as well as software technologies required for mandatory real time control loops, involving such actuators and sensors. The second class of technologies, generic to any magnetic fusion device, includes the superconducting magnet technologies, in order to provide a stationary confinement magnetic field, the actively cooled plasma facing components (PFCs) handling either radiated or convected power fluxes (often in excess of several tens of MW m-2), dedicated diagnostics monitoring the interfaces (e.g. infrared survey of PFCs), etc. The detailed specifications of all elements must comply with a reactor-relevant environment, in terms of operational parameters as well as lifetime. The paper presents a summary of the present status and understanding of the technology and science of steady-state operation in magnetically confined plasmas, as well as the forthcoming work programme dedicated to the vast R&D programme undertaken in this domain, in particular within the European fusion framework.

  14. Characteristics and plasma parameters of a short-wavelength low-pressure discharge lamp

    Science.gov (United States)

    Shuaibov, A. K.; Shevera, I. V.; Malinina, A. A.

    2008-10-01

    We have studied the working optical characteristics and electron kinetic coefficients of a short-wavelength, electric discharge exciplex-halogen UV-VUV lamp employing a mixture of argon and chlorine with a total pressure of P = 0.5 10 kPa. The lamp operates on a system of broadened electron-vibrational bands of ArCl (175 nm) and chlorine (200, 258 nm) molecules, which overlap to form a continuum in the spectral range of 160 260 nm. It is established that the optimum mixtures are those with p(Ar) - p(Cl2) = (2 4)-(0.15 0.30) kPa. The average output power of the short-wavelength radiation is 1 2 W at an efficiency of ˜5%. The electron energy distribution functions (EDFs) and the discharge plasma parameters have been calculated by solving the Boltzmann equation for a gas mixture with the experimentally determined optimum composition in the range of E/ P values from 1 to 200 V/(cm Torr), where E is the electric field strength and P is the total gas pressure. Using the obtained EDFs, the electron transport characteristics, specific discharge power losses for the main elementary processes, and rate constants of electron processes are determined.

  15. Diagnostics of recombining laser plasma parameters based on He-like ion resonance lines intensity ratios

    Science.gov (United States)

    Ryazantsev, S. N.; Skobelev, I. Yu; Faenov, A. Ya; Pikuz, T. A.; Grum-Grzhimailo, A. N.; Pikuz, S. A.

    2016-11-01

    While the plasma created by powerful laser expands from the target surface it becomes overcooled, i.e. recombining one. Improving of diagnostic methods applicable for such plasma is rather important problem in laboratory astrophysics nowadays because laser produced jets are fully scalable to young stellar objects. Such scaling is possible because of the plasma hydrodynamic equations invariance under some transformations. In this paper it is shown that relative intensities of the resonance transitions in He-like ions can be used to measure the parameters of recombining plasma. Intensity of the spectral lines corresponding to these transitions is sensitive to the density in the range of 1016-1020 cm-3 while the temperature ranges from 10 to 100 eV for ions with nuclear charge Zn ∼ 10. Calculations were carried out for F VIII ion and allowed to determine parameters of plasma jets created by nanosecond laser system ELFIE (Ecole Polytechnique, France) for astrophysical phenomenon modelling. Obtained dependencies are quite universal and can be used for any recombining plasma containing He-like fluorine ions.

  16. Expanding the Capabilities of the Pulsed Plasma Thruster for In-Space and Atmospheric Operation

    Science.gov (United States)

    Johnson, Ian Kronheim

    Of all in-space propulsion systems to date, the Pulsed Plasma Thruster (PPT) is unique in its simplicity and wide range of operational parameters. This study examined multiple uses of the thruster for in-space and atmospheric propulsion, as well as the creation of a CubeSat satellite and atmospheric airship as test beds for the thruster. The PPT was tested as a solid-propellant feed source for the High Power Helicon Thruster, a compact plasma source capable of generating order of magnitude higher plasma densities than comparable power level systems. Replacing the gaseous feed system reduced the thruster size and complexity, as well as allowing for extremely discrete discharges, minimizing the influence of wall effects. Teflon (C2F4) has been the traditional propellant for PPTs due to a high exhaust velocity and ability to ablate without surface modification over long durations. A number of alternative propellants, including minerals and metallics commonly found on asteroids, were tested for use with the PPT. Compounds with significant fractions of sulfur showed the highest performance increase, with specific thrusts double that of Teflon. A PPT with sulfur propellant designed for CubeSat operation, as well as the subsystems necessary for autonomous operation, was built and tested in the laboratory. The PPT was modified for use at atmospheric pressures where the impulse was well defined as a function of the discharge chamber volume, capacitor energy, and background pressure. To demonstrate that the air-breathing PPT was a viable concept the device was launched on two atmospheric balloon flights.

  17. Measurements of egg shell plasma parameters using laser-induced breakdown spectroscopy

    Indian Academy of Sciences (India)

    Wenfeng Luo; Xiaoxia Zhao; Shuyuan Lv; Haiyan Zhu

    2015-07-01

    Measurements of 1064 nm laser-induced egg shell plasma parameters are presented in this paper. Of special interests were its elemental identification and the determination of spectroscopic temperature and electron density. The electron temperature of 5956 K was inferred using an improved iterative Boltzmann plot method with six calcium atomic emission lines, and the electron number density of 6.1 × 1016 cm−3 was determined by measuring the width of Stark-broadened once-ionized calcium line at 393.37 nm. Based on the experimental results, the laser-induced egg shell plasma was verified to be optically thin and satisfy local thermodynamic equilibrium (LTE). Furthermore, experiments also demonstrated that the loss of energy due to the reflection of the laser beam from the plasma can be neglected and the inverse bremsstrahlung (IB) absorption was the dominant mechanism of plasma heating at the IR wavelength.

  18. Compatibility of advanced tokamak plasma with high density and high radiation loss operation in JT-60U

    Science.gov (United States)

    Takenaga, H.; Asakura, N.; Kubo, H.; Higashijima, S.; Konoshima, S.; Nakano, T.; Oyama, N.; Porter, G. D.; Rognlien, T. D.; Rensink, M. E.; Ide, S.; Fujita, T.; Takizuka, T.; Kamada, Y.; Miura, Y.; JT-60 Team

    2005-12-01

    Compatibility of advanced tokamak plasmas with high density and high radiation loss has been investigated in both reversed shear (RS) plasmas and high βp H-mode plasmas with a weak positive shear on JT-60U. In the RS plasmas, the operating regime is extended to high density above the Greenwald density (nGW) with high confinement (HHy2 > 1) and high radiation loss fraction (frad > 0.9) by tailoring the internal transport barriers (ITBs). With a small plasma-wall gap, the radiation loss in the main plasma (inside the magnetic separatrix) reaches 80% of the heating power due to metal impurity accumulation. However, high confinement of HHy2 = 1.2 is sustained even with such a large radiation loss in the main plasma. By neon seeding, the divertor radiation loss is enhanced from 20% to 40% of the total radiation loss. In the high βp H-mode plasmas, high confinement (HHy2 = 0.96) is maintained at high density ( \\bar{n}_{\\rme}/n_GW=0.92 ) with high radiation loss fraction (frad ~ 1) by utilizing high-field-side pellets and argon (Ar) injection. The high \\bar{n}_{\\rme}/n_GW is attributed to the formation of strong density ITB. Strong core-edge parameter linkage for confinement improvement is observed, where the pedestal pressure and the core plasma confinement increase together. The measured radiation profile including contributions from all impurities in the main plasma is peaked, and the central radiation is ascribed to the contribution from Ar accumulated inside the ITB. Impurity transport analyses indicate that the Ar density profile, twice as peaked as the electron density profile, which is the same level as that observed in the high βp H-mode plasma, can yield an acceptable radiation profile even with a peaked density profile in a fusion reactor.

  19. Lindhard's polarization parameter and atomic sum rules in the local plasma approximation

    DEFF Research Database (Denmark)

    Cabrera-Trujillo, R.; Apell, P.; Oddershede, J.

    2017-01-01

    In this work, we analyze the effects of Lindhard polarization parameter, χ, on the sum rule, Sp, within the local plasma approximation (LPA) as well as on the logarithmic sum rule Lp = dSp/dp, in both cases for the system in an initial excited state. We show results for a hydrogenic atom with nuc...

  20. Measurement Of Plasma Parameters In Micro-Discharge By Wall Probe

    Science.gov (United States)

    Saifutdinov, Almaz; Kudryavtsev, Anatoly; Sysoev, Sergey

    2016-09-01

    The increasing scientific and practical interest for glow discharge at high pressure is largely determined by the fact that their use does not require expensive and huge vacuum equipment. The analysis shows that, in contrast to the well-studied positive column (PC), the basic parameters of the plasma negative glow (NG) and Faraday dark space (FDS) of micro-discharges are studied insufficiently. The difficulties of the experimental diagnostics are associated with the fact that for the fixed values of pL with the increasing gas pressure the length of the micro-discharge decreases. And a small size is extremely difficult to diagnose spatial parameters distribution of micro discharges. Since at a small size introducing traditional Langmuir probe into the plasma capacity is not possible technically, it was proposed to use an additional measuring electrode (wall probe) disposed between the cathode and the anode for measurement of the fast EEDF. With its use we have registered EEDF fast electrons produced in the reaction of Penning ionization out of earlier reach range of high-pressure gas (from 20 to 200 Torr). In this paper by using wall probe we measured the basic parameters of NG plasma in micro-discharge in helium in a wide range of pressures. It is shown that the electrons temperature in the NG plasma is low and amounts to few fraction of 1 eV, which differs from the electron temperature in PC plasma. This allows the use of NG plasma for analysis by gas plasma electron spectroscopy. Authors thanks RNF (Grant 14-19-00311) for the support.

  1. Investigation of Normalization Methods using Plasma Parameters for Laser Induced Breakdown Spectroscopy (LIBS) under simulated Martian Conditions

    OpenAIRE

    Vogt, David; Schröder, Susanne; Hübers, H.-W.

    2017-01-01

    Laser Induced Breakdown Spectroscopy data need to be normalized, especially in the field of planetary exploration We investigated plasma parameters as temperature and electron density for this purpose.

  2. Effects of the electrical parameters and gas flow rate on the generation of reactive species in liquids exposed to atmospheric pressure plasma jets

    Science.gov (United States)

    Baek, Eun Jeong; Joh, Hea Min; Kim, Sun Ja; Chung, T. H.

    2016-07-01

    In this work, an atmospheric pressure plasma jet was fabricated and studied for plasma-liquid interactions. The plasma jet consists of a quartz-covered pin electrode and outer quartz tube with a tapered nozzle. Using the current-voltage (I-V) and optical emission characteristics of the plasma jet, the plasma density and the speed of the plume were investigated. The optical emission spectra clearly indicated the excited NO, O, OH, N2, and N2+ in the plasma plumes. Then the plasma jets were applied to the deionized water. We investigated the effects of the operating parameters such as applied voltage, pulse frequency, and gas flow rate on the generation of reactive species in the gas and liquid phases. The densities of reactive species including OH radicals were obtained at the plasma-liquid surface and inside the plasma-treated liquids using ultraviolet absorption spectroscopy and chemical probe method. The nitrite concentration was detected by Griess assay. The data are very suggestive that there is a strong correlation among the production of reactive oxygen and nitrogen species (RONS) in the plasmas and liquids.

  3. Method and Apparatus for Determining Operational Parameters of Thermoelectric Modules

    Science.gov (United States)

    Zybała, Rafał; Schmidt, Maksymilian; Kaszyca, Kamil; Ciupiński, Łukasz; Kruszewski, Mirosław J.; Pietrzak, Katarzyna

    2016-10-01

    The main aim of this work was to construct and test an apparatus for characterization of high temperature thermoelectric modules to be used in thermoelectric generator (TEGs) applications. The idea of this apparatus is based on very precise measurements of heat fluxes passing through the thermoelectric (TE) module, at both its hot and cold sides. The electrical properties of the module, under different temperature and load conditions, were used to estimate efficiency of energy conversion based on electrical and thermal energy conservation analysis. The temperature of the cold side, T c, was stabilized by a precise circulating thermostat (≤0.1°C) in a temperature range from 5°C to 90°C. The amount of heat absorbed by a coolant flowing through the heat sink was measured by the calibrated and certified heat flow meter with an accuracy better than 1%. The temperature of the hot side, T h, was forced to assumed temperature ( T max = 450°C) by an electric heater with known power ( P h = 0-600 W) with ample thermal insulation. The electrical power was used in calculations. The TE module, heaters and cooling plate were placed in an adiabatic vacuum chamber. The load characteristics of the module were evaluated using an electronically controlled current source as a load. The apparatus may be used to determine the essential parameters of TE modules (open circuit voltage, U oc, short circuit current, I sc, internal electrical resistance, R int, thermal resistance, R th, power density, and efficiency, η, as a function of T c and T h ). Several commercially available TE modules based on Bi2Te3 and Sb2Te3 alloys were tested. The measurements confirmed that the constructed apparatus was highly accurate, stable and yielded reproducible results; therefore, it is a reliable tool for the development of thermoelectric generators.

  4. The differing behavior of electrosurgical devices made of various electrode materials operating under plasma conditions

    Science.gov (United States)

    Stalder, K. R.; Ryan, T. P.; Gaspredes, J.; Woloszko, J.

    2015-03-01

    Coblation® is an electrosurgical technology which employs electrically-excited electrodes in the presence of saline solution to produce a localized and ionized plasma that can cut, ablate, and otherwise treat tissues for many different surgical needs. To improve our understanding of how Coblation plasmas develop from devices made from different electrode materials we describe several experiments designed to elucidate material effects. Initial experiments studied simple, noncommercial cylindrical electrode test devices operating in buffered isotonic saline without applied suction. The applied RF voltage, approximately 300 V RMS, was sufficient to form glow discharges around the active electrodes. The devices exhibited significantly different operating characteristics, which we ascribe to the differing oxidation tendencies and other physical properties of the electrode materials. Parameters measured include RMS voltage and current, instantaneous voltage and current, temporally-resolved light emission and optical emission spectra, and electrode mass-loss measurements. We correlate these measured properties with some of the bulk characteristics of the electrode materials such as work functions, standard reduction potentials and sputter yields.

  5. The effect of degeneracy parameter on Weibel instability in dense plasma

    Energy Technology Data Exchange (ETDEWEB)

    Mahdavi, M. [Physics Department, Mazandaran University, P.O. Box 47415-416 Babolsar (Iran, Islamic Republic of); Khodadadi Azadboni, F. [Physics Department, Mazandaran University, P.O. Box 47415-416 Babolsar (Iran, Islamic Republic of); Young Researchers Club, Sari Branch, Islamic Azad University, P.O. Box 48161-194 Sari (Iran, Islamic Republic of)

    2013-12-15

    In this paper, the role of degeneracy parameter, in both directions parallel and perpendicular with propagation direction of the laser beam in plasma, on the growth rate of Weibel instability, is studied. Calculations show that with the temperature anisotropy, β = T{sub ∥}/T{sub ⊥} = 0.2 and a 0.75 times reduction of the degeneracy parameter, the increased rate of the the Weibel instability growth rate is 72%. The degeneracy required for minimal growth rate in interaction laser plasma with a density of 1.2 × 10{sup 32}m{sup −3}, is larger than 3. The reduction of temperature and the degeneracy parameter of plasma in parallel direction will also increase growth rate about 30% more than incrossing degeneracy parameter in transverse direction. With the minimum pressure costs of cold compression, subsequent degeneracy parameters, and the minimum value of electron quiver energy, we can expect growth rate of Weibel instability order 0.01.

  6. OPTIMIZATION OF OPERATING PARAMETERS FOR EDM PROCESS BASED ON THE TAGUCHI METHOD AND ARTIFICIAL NEURAL NETWORK

    OpenAIRE

    A.Thillaivanan,; P. Asokan,; K.N.Srinivasan,; Saravanan, R.

    2010-01-01

    In this paper the complexity of electrical discharge machining process which is very difficult to determine optimal cutting parameters for improving cutting performance has been reported. Optimization of operating parameters is an important step in machining, particularly for operating unconventional machiningprocedure like EDM. A suitable selection of machining parameters for the electrical discharge machining process relies heavily on the operators’ technologies and experience because of th...

  7. Evolution of plasma parameters in an Ar-N2/He inductive plasma source with magnetic pole enhancement

    Science.gov (United States)

    Maria, Younus; N, U. Rehman; M, Shafiq; M, Naeem; M, Zaka-Ul-Islam; M, Zakaullah

    2017-02-01

    Magnetic pole enhanced inductively coupled plasmas (MaPE-ICPs) are a promising source for plasma-based etching and have a wide range of material processing applications. In the present study Langmuir probe and optical emission spectroscopy were used to monitor the evolution of plasma parameters in a MaPE-ICP Ar-N2/He mixture plasma. Electron density ({n}{{e}}) and temperature ({T}{{e}}), excitation temperature ({T}{{exc}}), plasma potential ({V}{{p}}), skin depth (δ ) and the evolution of the electron energy probability function (EEPF) are reported as a function of radiofrequency (RF) power, pressure and argon concentration in the mixture. It is observed that {n}{{e}} increases while {T}{{e}} decreases with increase in RF power and argon concentration in the mixture. The emission intensity of the argon line at 750.4 nm is also used to monitor the variation of the ‘high-energy tail’ of the EEPF with RF power and gas pressure. The EEPF has a ‘bi-Maxwellian’ distribution at low RF powers and higher pressure in a pure {{{N}}}2 discharge. However, it evolves into a ‘Maxwellian’ distribution at RF powers greater than 70 W for pure {{{N}}}2, and at 50 W for higher argon concentrations in the mixture. The effect of argon concentration on the temperatures of two electron groups in the ‘bi-Maxwellian’ EEPF is examined. The temperature of the low-energy electron group {T}{{L}} shows a decreasing trend with argon addition until the ‘thermalization’ of the two temperatures occurs, while the temperature of high-energy electrons {T}{{H}} decreases continuously.

  8. Simulation of Main Plasma Parameters of a Cylindrical Asymmetric Capacitively Coupled Plasma Micro-Thruster using Computational Fluid Dynamics

    Directory of Open Access Journals (Sweden)

    Amelia eGreig

    2015-01-01

    Full Text Available Computational fluid dynamics (CFD simulations of a radio-frequency (13.56 MHz electro-thermal capacitively coupled plasma (CCP micro-thruster have been performed using the commercial CFD-ACE+ package. Standard operating conditions of a 10 W, 1.5 Torr argon discharge were used to compare with previously obtained experimental results for validation. Results show that the driving force behind plasma production within the thruster is ion-induced secondary electrons ejected from the surface of the discharge tube, accelerated through the sheath to electron temperatures up to 33.5 eV. The secondary electron coefficient was varied to determine the effect on the discharge, with results showing that full breakdown of the discharge did not occur for coefficients coefficients less than or equal to 0.01.

  9. Effect of Plasma Nitriding Parameters on the Wear Resistance of Alloy Inconel 718

    Science.gov (United States)

    Kovací, Halim; Ghahramanzadeh ASL, Hojjat; Albayrak, Çigdem; Alsaran, Akgün; Çelik, Ayhan

    2016-11-01

    The effect of the temperature and duration of plasma nitriding on the microstructure and friction and wear parameters of Inconel 718 nickel alloy is investigated. The process of plasma nitriding is conducted in a nitrogen-hydrogen gaseous mixture at a temperature of 400, 500 and 600°C for 1 and 4 h. The modulus of elasticity of the nitrided layer, the micro- and nanohardness, the surface roughness, the friction factor and the wear resistance of the alloy are determined prior to and after the nitriding. The optimum nitriding regime providing the best tribological characteristics is determined.

  10. Effect of process parameters on induction plasma reactive deposition of tungsten carbide from tungsten metal powder

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Tungsten carbide deposit was made directly from tungsten metal powder through the reaction with methane in radio frequency induction plasma. Effect of major process parameters on the induction plasma reactive deposition of tungsten carbide was studied by optical microscopy, scanning electron microscopy, X-ray diffraction analysis, water displacement method, and microhardness test. The results show that methane flow rate, powder feed rate, particle size, reaction chamber pressure and deposition distance have significant influences on the phase composition, density, and microhardness of the deposit. Extra carbon is necessary to ensure the complete conversion of tungsten metal into the carbide.

  11. Two-Parameter Radon Transformation of the Wigner Operator and Its Inverse

    Institute of Scientific and Technical Information of China (English)

    范洪义; 程海凌

    2001-01-01

    Using the technique of integration within an ordered product of operators, we reveal that a new quantum mechanical representation |x, μ,v〉exists, the eigenvector of operator μQ + νP (linear combination of coordinate Q and momentum P) with eigenvalue x, which is inherent to the two-parameter (μ, ν) Radon transformation of the Wigner operator. It turns out that the projection operator |x,μ,ν> operator. The inverse of operator Radon transformation is also derived which indicates tomography in operator version.

  12. The Main Issues to Address in Modeling Plasma Spray Torch Operation

    Science.gov (United States)

    Chazelas, C.; Trelles, J. P.; Vardelle, A.

    2017-01-01

    The modeling of plasma torch operation has advanced greatly in the last 15 years due to a better understanding of the underlying physics, development of commercial, open-source computational fluid dynamics softwares, and access to high performance and cloud computing. However, the operation mode of the electric arc in plasma torches is controlled by dynamic, thermal, electromagnetic, acoustic and chemical phenomena that take place at different scales and whose interactions are not completely understood yet. Even though no single model of plasma torch operation fully addresses these phenomena, most of these models are useful tools for parametric studies, if their use is reinforced by knowledge of torch operation and the model predictions are validated against experimental data. To increase the level of predictability of the current models, several further steps are needed. This study examines the issues remaining to be addressed in the modeling of plasma spray torch operation and the current critical aspects of these.

  13. A Multi-Agents Architecture to Learn Vision Operators and their Parameters

    Directory of Open Access Journals (Sweden)

    Issam Qaffou

    2012-05-01

    Full Text Available In a vision system, every task needs that the operators to apply should be well chosen and their parameters should be also well adjusted . The diversity of operators and the multitude of their parameters constitute a big challenge for users. As it is very difficult to make the right choice, lack of a specific rule, many disadvantages appear and affect the computation time and especially the quality of results. In this paper we present a multi-agent architecture to learn the best operators to apply and their best parameters for a class of images. Our architecture consists of three types of agents: User Agent, Operator Agent and Parameter Agent. The User Agent determines the phases of treatment, a library of operators and the possible values of their parameters. The Operator Agent constructs all possible combinations of operators and the Parameter Agent, the core of the architecture, adjusts the parameters of each combination by treating a large number of images. Through the reinforcement learning mechanism, our architecture does not consider only the system opportunities but also the user preferences.

  14. The Impact of Operating Parameters and Correlated Parameters for Extended BWR Burnup Credit

    Energy Technology Data Exchange (ETDEWEB)

    Ade, Brian J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Marshall, William B. J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ilas, Germina [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Betzler, Benjamin R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bowman, Stephen M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-06-01

    Applicants for certificates of compliance for spent nuclear fuel (SNF) transportation and dry storage systems perform analyses to demonstrate that these systems are adequately subcritical per the requirements of Title 10 of the Code of Federal Regulations (10 CFR) Parts 71 and 72. For pressurized water reactor (PWR) SNF, these analyses may credit the reduction in assembly reactivity caused by depletion of fissile nuclides and buildup of neutron-absorbing nuclides during power operation. This credit for reactivity reduction during depletion is commonly referred to as burnup credit (BUC). US Nuclear Regulatory Commission (NRC) staff review BUC analyses according to the guidance in the Division of Spent Fuel Storage and Transportation Interim Staff Guidance (ISG) 8, Revision 3, Burnup Credit in the Criticality Safety Analyses of PWR Spent Fuel in Transportation and Storage Casks.

  15. Control of arc plasma torches: compensation of operational enthalpy drifts

    Energy Technology Data Exchange (ETDEWEB)

    Oliver, D H; Alexieva, J; Djakov, B E; Enikov, R [Institute of Electronics, Bulgarian Academy of Sciences, 72 Tzarigradsko Chaussee, 1784 Sofia (Bulgaria); Dimitrov, D [Centre of Biomedical Engineering, Bulgarian Academy of Sciences, Acad. G. Bonchev Str., Bl. 105, 1113 Sofia (Bulgaria)], E-mail: dick.oliver@gmail.com

    2008-05-01

    In arc plasma torches electrode wear is the main reason for slow changes in the electrical and thermal torch characteristics. Such effects hinder technological applications of this type of plasma torches whenever the enthalpy must be maintained at a fixed level, or varied as needed. To solve this problem, a new method and algorithm for torch control are proposed. The time evolution of the arc current, voltage and thermal power loss of the torch are recorded. The values measured are used to find the required value of the enthalpy.

  16. Modeling a short cold cathode DC discharge device with controllable plasma parameters

    Science.gov (United States)

    Kudryavtsev, Anatoly; Adams, Steven; Demidov, Vladimir; Bogdanov, Yevgeny

    2009-11-01

    A short (without positive column) DC gas-discharge device with a cold cathode has been modeled. The device consists of the plane disk-shaped cathode and anode while the inter-electrode gap is bounded by a cylindrical wall. The cathode and anode are each 2.5 cm in diameter, and the inter-electrode gap is 12 mm. The wall is made of conducting parts divided by an insulator. The modeling has been performed for argon plasma at 1 Torr pressure. It is demonstrated in the model that spatial distributions of electron density and temperature and argon metastable atom density depend on the DC voltage applied to different conducting parts of the wall. Applied voltage can trap within the device volume energetic electrons arising from atomic and molecular processes in the plasma. This leads to a modification in the heating of slow electrons by energetic electrons and as a result modifies the controlling plasma parameters.

  17. Parameters Optimization of Plasma Hardening Process Using Genetic Algorithm and Neural Network

    Institute of Scientific and Technical Information of China (English)

    LIU Gu; WANG Liu-ying; CHEN Gui-ming; HUA Shao-chun

    2011-01-01

    Plasma surface hardening process was performed to improve the performance of the AISI 1045 carbon steel.Experiments were carried out to characterize the hardening qualities.A predicting and optimizing model using genetic algorithm-back propagation neural network(GA-BP) was developed based on the experimental results.The non-linear relationship between properties of hardening layers and process parameters was established.The results show that the GA-BP predicting model is reliable since prediction results are in rather good agreement with measured results.The optimal properties of the hardened layer were deduced from GA.And through multi optimizations,the optimum comprehensive performances of the hardened layer were as follows:plasma arc current is 90 A,hardening speed is 2.2 m/min,plasma gas flow rate is 6.0 L/min and hardening distance is 4.3 mm.It concludes that GA-BP mode developed in this study provides a promising method for plasma hardening parameters prediction and optimization.

  18. Life Prediction of Atmospheric Plasma-Sprayed Thermal Barrier Coatings Using Temperature-Dependent Model Parameters

    Science.gov (United States)

    Zhang, B.; Chen, Kuiying; Baddour, N.; Patnaik, P. C.

    2017-06-01

    The failure analysis and life prediction of atmospheric plasma-sprayed thermal barrier coatings (APS-TBCs) were carried out for a thermal cyclic process. A residual stress model for the top coat of APS-TBC was proposed and then applied to life prediction. This residual stress model shows an inversion characteristic versus thickness of thermally grown oxide. The capability of the life model was demonstrated using temperature-dependent model parameters. Using existing life data, a comparison of fitting approaches of life model parameters was performed. A larger discrepancy was found for the life predicted using linearized fitting parameters versus temperature compared to those using non-linear fitting parameters. A method for integrating the residual stress was proposed by using the critical time of stress inversion. The role of the residual stresses distributed at each individual coating layer was explored and their interplay on the coating's delamination was analyzed.

  19. Self-bias Dependence on Process Parameters in Asymmetric Cylindrical Coaxial Capacitively Coupled Plasma

    CERN Document Server

    Upadhyay, J; Popović, S; Valente-Feliciano, A -M; Phillips, L; Vušković, L

    2015-01-01

    An rf coaxial capacitively coupled Ar/Cl2 plasma is applied to processing the inner wall of superconducting radio frequency cavities. A dc self-bias potential is established across the inner electrode sheath due to the surface area difference between inner and outer electrodes of the coaxial plasma. The self-bias potential measurement is used as an indication of the plasma sheath voltage asymmetry. The understanding of the asymmetry in sheath voltage distribution in coaxial plasma is important for the modification of the inner surfaces of three dimensional objects. The plasma sheath voltages were tailored to process the outer wall by providing an additional dc current to the inner electrode with the help of an external dc power supply. The dc self-bias potential is measured for different diameter electrodes and its variation on process parameters such as gas pressure, rf power and percentage of chlorine in the Ar/Cl2 gas mixture is studied. The dc current needed to overcome the self-bias potential to make it ...

  20. Modeling and experiments on differential pumping in linear plasma generators operating at high gas flows

    NARCIS (Netherlands)

    van Eck, H. J. N.; Koppers, W. R.; van Rooij, G. J.; W. J. Goedheer,; Engeln, R.; D.C. Schram,; Cardozo, N. J. L.; Kleyn, A. W.

    2009-01-01

    The direct simulation Monte Carlo (DSMC) method was used to investigate the efficiency of differential pumping in linear plasma generators operating at high gas flows. Skimmers are used to separate the neutrals from the plasma beam, which is guided from the source to the target by a strong axial mag

  1. The possible role of hydrogen sulfide as a modulator of hemostatic parameters of plasma.

    Science.gov (United States)

    Olas, Beata; Kontek, Bogdan

    2014-09-05

    Hydrogen sulfide (H2S) is a well known toxic gas at high levels. However, at physiological levels, H2S may play a role in the pathogenesis of various cardiovascular diseases. The objective was to study the effects of exogenous H2S on the hemostatic parameters (coagulation and fibrinolytic activity) of human plasma. Human plasma was incubated (5, 15 and 30 min) with NaHS as a H2S donor at the final concentration of 0.01-100 μM. Hemostatic factors, such as maximum velocity of clot formation, fibrin lysis half-time, the activated partial thromboplastin time (APTT), prothrombin time (PT), and thrombin time (TT) were estimated. Moreover, the aim of our study was to establish the influence of NaHS (10 μM; 5, 15 and 30 min) on the clot formation using the purified fibrinogen. We demonstrated that coagulation/fibrinolytic properties of human plasma incubated with NaHS were changed. APPT, PT and TT of plasma treated with NaHS at tested concentrations--0.01-100 μM were prolonged. We observed that NaHS (0.01-100 μM) reduced fibrin polymerization in whole plasma and 10 μM NaHS also reduced polymerization of purified fibrinogen. In the presence of NaHS (at the low tested concentration--1 μM) the decrease was about 18% (in plasma, p<0.05). Our experiments also showed that NaHS (0.01-100 μM) stimulated the fibrin lysis in whole plasma. However, the time-dependent (5, 15 and 30 min) reduction of fibrin/fibrinogen polymerization and stimulation of fibrin lysis by NaHS (10 μM) was not observed. In conclusion, the present study demonstrates the anticoagulant properties of exogenous H2S in vitro.

  2. Versatile particle collection concept for correlation of particle growth and discharge parameters in dusty plasmas

    Science.gov (United States)

    Hinz, A. M.; von Wahl, E.; Faupel, F.; Strunskus, T.; Kersten, H.

    2015-02-01

    The feasibility of collecting nanoparticles from a dusty plasma by means of the neutral drag force is investigated. The nanoparticles are formed in a capacitively coupled asymmetric discharge running in an Ar/C2H2—mixture at a frequency of 13.56 MHz and an RF-power of 9 W. By opening a gate valve between the plasma reactor and a vacuum chamber at a lower pressure at any desired point of the growth cycle of the dust particles a neutral gas flux is induced that drags the particles out of the plasma onto a substrate. By changing the parameters of the collection process, e.g. the substrate positioning or the substrate temperature, the efficiency of the collection process can be adjusted. Information about the particle size distributions is obtained by performing ex situ SEM measurements. As the collection process creates a time stamp in the in situ recorded control parameters, e.g. the self-bias voltage or the process gas pressure, a direct and precise correlation between the control parameters and the particle size distribution is obtained.

  3. Dynamics of plasma catecholamine and corticosterone concentrations during reinforced and extinguished operant behavior in rats

    NARCIS (Netherlands)

    de Boer, S.F.; de Beun, R; Slangen, J L; van der Gugten, J

    1990-01-01

    Plasma noradrenaline (NA), adrenaline (A) and corticosterone (CS) concentrations were determined simultaneously in permanently heart-cannulated rats before and during the performance of reinforced and nonreinforced (extinguished) operant behavior. Shortly before the experimental food-reinforced (VI

  4. Dynamics of plasma catecholamine and corticosterone concentrations during reinforced and extinguished operant behavior in rats

    NARCIS (Netherlands)

    de Boer, S.F.; de Beun, R; Slangen, J L; van der Gugten, J

    Plasma noradrenaline (NA), adrenaline (A) and corticosterone (CS) concentrations were determined simultaneously in permanently heart-cannulated rats before and during the performance of reinforced and nonreinforced (extinguished) operant behavior. Shortly before the experimental food-reinforced (VI

  5. A Multi-Parameter Optimization of Plasma Density for an Advanced Linear Collider*

    CERN Document Server

    Muggli, P; Hillenbrand, S

    2011-01-01

    Recent plasma wakefield accelerator (PWFA) experiments showed that an accelerating gradient as high as 50 GV/m can be driven and sustained over a meter-long plasma [1]. Based on this result, a straw man design for a future, multi-stage, PWFA-based electron/positron collider with an energy gain of ~ 25 GeV/stage has been generated [2]. However, the choice of plasma density remains open. On one hand, high density means large accelerating gradients and possibly a shorter collider. On the other it means that the accelerating structure dimensions become very small, on the order of the plasma wavelength. Operating at high gradient and with such small structure imposes very strong constraints on the particle bunches: small dimensions and spacing, large current or limited charge, etc. These constraints result is challenges in producing the bunches (compression, shaping for optimum loading, etc.) and could limit the achievable collider luminosity. We explore the global implications of operating at a lower accelerating...

  6. Review & Peer Review of “Parameters for Properly Designed and Operated Flares” Documents

    Science.gov (United States)

    This page contains two 2012 memoranda on the review of EPA's parameters for properly designed and operated flares. One details the process of peer review, and the other provides background information and specific charge questions to the panel.

  7. DEFINITION OF OPERATING PARAMETERS OUTPUT RANGE OF FUNCTIONAL SUBSYSTEMS HYDRAULIC SYSTEMS OF THE AIRCRAFT

    Directory of Open Access Journals (Sweden)

    M. A. Bobrin

    2014-01-01

    Full Text Available To evaluate the operational tolerance field hydraulic output parameters under various working conditions and the flight stages are mathematical relationships and the results obtained in the environment Mathcad in graphical form.

  8. The effect of operational parameters on the photocatalytic degradation of pesticide.

    Science.gov (United States)

    Choi, Euiso; Cho, Il-Hyoung; Park, Jaehong

    2004-01-01

    The photocatalytic degradation of Cartap Hydrochloride, a synthetic pesticide. has been investigated over coated TiO2 photocatalysts irradiated with a ultraviolet (UV) light. The effect of operational parameters, i.e., Cartap Hydrochloride concentration, reaction time, light intensity and additive on the degradation rate of aqueous solution of Cartap Hydrochloride has been examined. Results show that the employment of efficient photocatalysts and the selection of optimal operational parameters may lead to degradation of Cartap Hydrochloride solutions.

  9. A Multi-parameter Data Acquisition and Analysis System Based on Open VMS Operation System

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    We fall into disuse the JUHU system based on the PDP/11 computer for RSX11M operation system,and update our multi-parameter data aequisition and analysis system’s hardware and software based on VAXII computer and Open VMS operation system,make it adapted to the recent physics experiment.In this paper,we describe the updated inulti-parameter data acquisition and analysis system’s hardware,software configuration and system function.

  10. Modeling Approach and Analysis of the Structural Parameters of an Inductively Coupled Plasma Etcher Based on a Regression Orthogonal Design

    Institute of Scientific and Technical Information of China (English)

    CHENG Jia; ZHU Yu; JI Linhong

    2012-01-01

    The geometry of an inductively coupled plasma (ICP) etcher is usually considered to be an important factor for determining both plasma and process uniformity over a large wafer. During the past few decades, these parameters were determined by the "trial and error" method, resulting in wastes of time and funds. In this paper, a new approach of regression orthogonal design with plasma simulation experiments is proposed to investigate the sensitivity of the structural parameters on the uniformity of plasma characteristics. The tool for simulating plasma is CFD-ACE+, which is commercial multi-physical modeling software that has been proven to be accurate for plasma simulation. The simulated experimental results are analyzed to get a regression equation on three structural parameters. Through this equation, engineers can compute the uniformity of the electron number density rapidly without modeling by CFD-ACE+. An optimization performed at the end produces good results.

  11. Experimental investigation of a draft tube spouted bed for effects of geometric parameters on operation

    DEFF Research Database (Denmark)

    Azizaddini, Seyednezamaddin; Lin, Weigang; Dam-Johansen, Kim

    2016-01-01

    Experiments are performed in a draft tube spouted bed (DTSB) to investigate effects of the operating conditions and the geometric parameters on the hydrodynamics. Geometry parameters, such as heights of the entrained zone, draft tube inner diameter, inner angle of the conical section were studied...

  12. Operation of a microwave plasma source for electron heating and antenna testing

    Science.gov (United States)

    Caughman, J. B. O.; Bigelow, T. S.; Diem, S. J.; Goulding, R. H.; Rasmussen, D. A.; Schaich, C. R.; White, T. L.

    2011-10-01

    One of the major challenges for magnetic fusion is the interaction of the plasma with materials. Linear plasma-material interaction test stands can benefit from additional electron heating of the high-density source plasma to increase the total plasma heat flux at the target to better simulate fusion reactor conditions (10-20 MW/m2). A microwave-based plasma experiment has begun at ORNL to study electron heating of over-dense plasmas and to provide a plasma environment for antenna testing. The plasma is generated by high-field launched whistler waves at 18 GHz to create a moderate-density plasma (ne ~1018/m3). Electron heating of the over-dense plasma is provided by either whistler waves or electron Bernstein waves at 6 GHz. In addition, a single strap mockup antenna, designed to operate at 40-50 MHz, is being constructed to study near-field plasma interactions. The antenna will be placed in the experiment's central vacuum chamber, which will act as an rf test facility. ORNL is managed by UT-Battelle, LLC, for the U.S. DOE under contract DE-AC-05-00OR22725.

  13. Intrahippocampal Infusion of Crotamine Isolated from Crotalus durissus terrificus Alters Plasma and Brain Biochemical Parameters

    Directory of Open Access Journals (Sweden)

    Rithiele Gonçalves

    2014-11-01

    Full Text Available Crotamine is one of the main constituents of the venom of the South American rattlesnake Crotalus durissus terrificus. Here we sought to investigate the inflammatory and toxicological effects induced by the intrahippocampal administration of crotamine isolated from Crotalus whole venom. Adult rats received an intrahippocampal infusion of crotamine or vehicle and were euthanized 24 h or 21 days after infusion. Plasma and brain tissue were collected for biochemical analysis. Complete blood count, creatinine, urea, glutamic oxaloacetic transaminase (GOT, glutamic pyruvic transaminase (GPT, creatine-kinase (CK, creatine kinase-muscle B (CK-MB and oxidative parameters (assessed by DNA damage and micronucleus frequency in leukocytes, lipid peroxidation and protein carbonyls in plasma and brain were quantified. Unpaired and paired t-tests were used for comparisons between saline and crotamine groups, and within groups (24 h vs. 21 days, respectively. After 24 h crotamine infusion promoted an increase of urea, GOT, GPT, CK, and platelets values (p ≤ 0.01, while red blood cells, hematocrit and leukocytes values decreased (p ≤ 0.01. Additionally, 21 days after infusion crotamine group showed increased creatinine, leukocytes, TBARS (plasma and brain, carbonyl (plasma and brain and micronucleus compared to the saline-group (p ≤ 0.01. Our findings show that crotamine infusion alter hematological parameters and cardiac markers, as well as oxidative parameters, not only in the brain, but also in the blood, indicating a systemic pro-inflammatory and toxicological activity. A further scientific attempt in terms of preserving the beneficial activity over toxicity is required.

  14. Schur parameters, Toeplitz matrices, and Kre\\u{\\i}n shorted operators

    CERN Document Server

    Arlinskii, Yury

    2011-01-01

    We establish connections between Schur parameters of the Schur class operator-valued functions, the corresponding simple conservative realizations, lower triangular Toeplitz matrices, and Kre\\u\\i n shorted operators. By means of Schur parameters or shorted operators for defect operators of Toeplitz matrices necessary and sufficient conditions for a simple conservative discrete-time system to be controllable/observable and for a completely non-unitary contraction to be completely non-isometric/completely non-co-isometric are obtained. For the Schur problem a characterization of central solution and uniqueness criteria to the solution are given in terms of shorted operators for defect operators of contractive Toeplitz matrices, corresponding to data.

  15. Reconstruction of the ion plasma parameters from the current measurements: mathematical tool

    Directory of Open Access Journals (Sweden)

    E. Séran

    Full Text Available Instrument d’Analyse du Plasma (IAP is one of the instruments of the newly prepared ionospheric mission Demeter. This analyser was developed to measure flows of thermal ions at the altitude of ~ 750 km and consists of two parts: (i retarding potential analyser (APR, which is utilised to measure the energy distribution of the ion plasma along the sensor look direction, and (ii velocity direction analyser (ADV, which is used to measure the arrival angle of the ion flow with respect to the analyser axis. The necessity to obtain quick and precise estimates of the ion plasma parameters has prompted us to revise the existing mathematical tool and to investigate different instrumental limitations, such as (i finite angular aperture, (ii grid transparency, (iii potential depression in the space between the grid wires, (iv losses of ions during their passage between the entrance diaphragm and the collector. Simple analytical expressions are found to fit the currents, which are measured by the APR and ADV collectors, and show a very good agreement with the numerical solutions. It was proven that the fitting of the current with the model functions gives a possibility to properly resolve even minor ion concentrations and to find the arrival angles of the ion flow in the multi-species plasma. The discussion is illustrated by an analysis of the instrument response in the ionospheric conditions which are predicted by the International Reference Ionosphere (IRI model.

    Key words. Ionosphere (plasma convection; instruments and techniques – Space plasma physics (experimental and mathematical techniques

  16. STUDY ON THE RELATIONSHIP BETWEEN ADJUSTABLE OPERATIONAL PARAMETERS AND NOISE OF SINGLE-CYLINDER DIESEL ENGINE

    Institute of Scientific and Technical Information of China (English)

    何勇; 鲍一丹

    2001-01-01

    A Model S195 (8.8 kW) single cylinder was used in this study to determine the effect of four operational parameters, i.e. intake valve close angle, exhaust valve open angle, fuel delivery angle and fuel injection pressure on noise. Single factor and multi-factor quadratic regressive orthogonal methods were adopted in the experiments to find the relationship between the four parameters and noise. By means of optimization technique, the optimum operational parameters for two working conditions of the engine were selected and the test results showed that optimum adjustment could reduce noise by 2-4 dB.

  17. Influence of operating parameters on lead removal from wastewater by phosphogypsum.

    Science.gov (United States)

    Balkaya, N; Cesur, H

    2003-06-01

    The aim of this study was to investigate the influence of operating parameters on lead removal from wastewater by phosphogypsum. Batch adsorption studies were carried out to examine the effect of these parameters on lead removal from wastewater. The operating parameters investigated were adsorbent dosage, contact time, pH and initial lead concentration. Adsorption isotherms were modelled with the help of both Langmuir and Freundlich formulae. The kinetics of the adsorption process which is important in the design of waste treatment systems, was also studied.

  18. A Spectral Representation for Spin-Weighted Spheroidal Wave Operators with Complex Aspherical Parameter

    CERN Document Server

    Finster, Felix

    2015-01-01

    A family of spectral decompositions of the spin-weighted spheroidal wave operator is constructed for complex aspherical parameters with bounded imaginary part. As the operator is not symmetric, its spectrum is complex and Jordan chains may appear. We prove uniform upper bounds for the length of the Jordan chains and the norms of the idempotent operators mapping onto the invariant subspaces. The completeness of the spectral decomposition is proven.

  19. Rocket measurements within a polar cap arc - Plasma, particle, and electric circuit parameters

    Science.gov (United States)

    Weber, E. J.; Ballenthin, J. O.; Basu, S.; Carlson, H. C.; Hardy, D. A.; Maynard, N. C.; Kelley, M. C.; Fleischman, J. R.; Pfaff, R. F.

    1989-01-01

    Results are presented from the Polar Ionospheric Irregularities Experiment (PIIE), conducted from Sondrestrom, Greenland, on March 15, 1985, designed for an investigation of processes which lead to the generation of small-scale (less than 1 km) ionospheric irregularities within polar-cap F-layer auroras. An instrumented rocket was launched into a polar cap F layer aurora to measure energetic electron flux, plasma, and electric circuit parameters of a sun-aligned arc, coordinated with simultaneous measurements from the Sondrestrom incoherent scatter radar and the AFGL Airborne Ionospheric Observatory. Results indicated the existence of two different generation mechanisms on the dawnside and duskside of the arc. On the duskside, parameters are suggestive of an interchange process, while on the dawnside, fluctuation parameters are consistent with a velocity shear instability.

  20. A battery-operated atmospheric-pressure plasma wand for biomedical applications

    Science.gov (United States)

    Pei, X.; Liu, J.; Xian, Y.; Lu, X.

    2014-04-01

    A handheld, battery-operated atmospheric-pressure plasma rod (named the plasma wand) which does not rely on an external power source (e.g. mains power or a power generator) or gas supply is reported. The plasma wand can be used for killing bacteria, fungi or viruses that are hidden in narrow channels such as the nasal cavity and ear canal, which are difficult to access using most currently available devices. Besides, the electrical characterization, plasma wand temperature, emission spectra of the plasma, ozone and OH radical concentration generated by the device, are investigated by different diagnostic methods. The ozone concentration reaches 120 ppm 1 mm away from the device and the OH concentration reaches 3.5 × 1014 cm-3 in the plasma. The preliminary bacteria inactivation experiment results show that all the bacteria samples on the microfiltration membrane are killed by this device within 30 s.

  1. Effect of process parameters on coating composition of cathodic-plasma-electrolysis-treated copper

    Indian Academy of Sciences (India)

    ASIYEH HABIBI; S MOHAMMAD MOUSAVI KHOIE; FARZAD MAHBOUBI; MUSTAFA URGEN

    2017-04-01

    Cathodic plasma electrolysis is a novel technique to form nanostructured layers on metallic surfaces by application of high voltage in a suitable aqueous electrolyte. In the present study, copper is treated by plasma electrolysisin 50 vol% ethanol electrolyte and coatings comprising carbon nanostructure and copper oxide are formed on the copper. The effect of some process parameters such as electrical conductivity, volume and temperature of electrolyte and ratio of anode to cathode surface area on current–voltage behaviour and subsequently coating compositions are investigated at 150V deposition voltage. The composition and morphology of these coatings are characterized by X-ray diffraction, Raman spectroscopy and scanning electron microscopy. Different current–voltage behaviours, temperatures of substrate and the contents and energies of radicals and ions around the substrate by changes in the mentioned parameters cause different compositions from 100 vol% copper oxide to different ratios of copper oxide to carbon, the structure changing from amorphous to graphitic structure in carbon and amorphous to cubic morphology in copper oxide on the substrate. Therefore, the understanding of cathodic plasma electrolysiscan be developed.

  2. DYNAMIC OF CHANGES OF BLOOD PLASMA ENERGY METABOLISM PARAMETERS IN SUCKLING COWS DURING CALVING INTERVAL

    Directory of Open Access Journals (Sweden)

    Ales Pavlik

    2015-02-01

    Full Text Available In this study, effect of environmental condition changes during gazing period on energy metabolism parameters was investigated. Totally 40 Aberdeen Angus cows were selected for observation. Calving all of cows was situated into March. The feeding ration for the animals was comprised by pasture during the grazing period and corn silage, hay and granulated distiller’s grains during the winter period. At average age 9 days before calving, and subsequently 10, 81, 151, 189 and 273 days after calving, blood was sampled and analysed for glucose and NEFA (non-esterified fatty acid concentrations on KONELAB T20xt automatic analyser (Thermo Fisher Scientific, Finland and currently available commercial kits (Biovendor-Laboratorni medicina, Czech Republic. A rapid increase (p < 0.05 of glucose concentration was detected in blood plasma of cows in period before calving to 81 days post partum. Average value of glucose concentration at 273 days postpartum was significant (p < 0.05 lower comparing to day 189. The highest concentrations of NEFA in blood plasma of cows were found at 10 day postpartum. After that, during the persisted higher temperature period the NEFA concentration decreased significantly (p < 0.01 till 189 days postpartum. At the end of monitored period concentration of NEFA in blood plasma significantly decreased (p < 0.05. Changes of hot and cold season during the grazing period probably according to forage quality and had significant effects on blood plasma NEFA and glucose concentrations.

  3. Inversion for Refractivity Parameters Using a Dynamic Adaptive Cuckoo Search with Crossover Operator Algorithm.

    Science.gov (United States)

    Zhang, Zhihua; Sheng, Zheng; Shi, Hanqing; Fan, Zhiqiang

    2016-01-01

    Using the RFC technique to estimate refractivity parameters is a complex nonlinear optimization problem. In this paper, an improved cuckoo search (CS) algorithm is proposed to deal with this problem. To enhance the performance of the CS algorithm, a parameter dynamic adaptive operation and crossover operation were integrated into the standard CS (DACS-CO). Rechenberg's 1/5 criteria combined with learning factor were used to control the parameter dynamic adaptive adjusting process. The crossover operation of genetic algorithm was utilized to guarantee the population diversity. The new hybrid algorithm has better local search ability and contributes to superior performance. To verify the ability of the DACS-CO algorithm to estimate atmospheric refractivity parameters, the simulation data and real radar clutter data are both implemented. The numerical experiments demonstrate that the DACS-CO algorithm can provide an effective method for near-real-time estimation of the atmospheric refractivity profile from radar clutter.

  4. Inversion for Refractivity Parameters Using a Dynamic Adaptive Cuckoo Search with Crossover Operator Algorithm

    Directory of Open Access Journals (Sweden)

    Zhihua Zhang

    2016-01-01

    Full Text Available Using the RFC technique to estimate refractivity parameters is a complex nonlinear optimization problem. In this paper, an improved cuckoo search (CS algorithm is proposed to deal with this problem. To enhance the performance of the CS algorithm, a parameter dynamic adaptive operation and crossover operation were integrated into the standard CS (DACS-CO. Rechenberg’s 1/5 criteria combined with learning factor were used to control the parameter dynamic adaptive adjusting process. The crossover operation of genetic algorithm was utilized to guarantee the population diversity. The new hybrid algorithm has better local search ability and contributes to superior performance. To verify the ability of the DACS-CO algorithm to estimate atmospheric refractivity parameters, the simulation data and real radar clutter data are both implemented. The numerical experiments demonstrate that the DACS-CO algorithm can provide an effective method for near-real-time estimation of the atmospheric refractivity profile from radar clutter.

  5. Impact of Reactor Operating Parameters on Cask Reactivity in BWR Burnup Credit

    Energy Technology Data Exchange (ETDEWEB)

    Ilas, Germina [ORNL; Betzler, Benjamin R [ORNL; Ade, Brian J [ORNL

    2017-01-01

    This paper discusses the effect of reactor operating parameters used in fuel depletion calculations on spent fuel cask reactivity, with relevance for boiling-water reactor (BWR) burnup credit (BUC) applications. Assessments that used generic BWR fuel assembly and spent fuel cask configurations are presented. The considered operating parameters, which were independently varied in the depletion simulations for the assembly, included fuel temperature, bypass water density, specific power, and operating history. Different operating history scenarios were considered for the assembly depletion to determine the effect of relative power distribution during the irradiation cycles, as well as the downtime between cycles. Depletion, decay, and criticality simulations were performed using computer codes and associated nuclear data within the SCALE code system. Results quantifying the dependence of cask reactivity on the assembly depletion parameters are presented herein.

  6. Optimization principle of operating parameters of heat exchanger by using CFD simulation

    Science.gov (United States)

    Mičieta, Jozef; Jiří, Vondál; Jandačka, Jozef; Lenhard, Richard

    2016-03-01

    Design of effective heat transfer devices and minimizing costs are desired sections in industry and they are important for both engineers and users due to the wide-scale use of heat exchangers. Traditional approach to design is based on iterative process in which is gradually changed design parameters, until a satisfactory solution is achieved. The design process of the heat exchanger is very dependent on the experience of the engineer, thereby the use of computational software is a major advantage in view of time. Determination of operating parameters of the heat exchanger and the subsequent estimation of operating costs have a major impact on the expected profitability of the device. There are on the one hand the material and production costs, which are immediately reflected in the cost of device. But on the other hand, there are somewhat hidden costs in view of economic operation of the heat exchanger. The economic balance of operation significantly affects the technical solution and accompanies the design of the heat exchanger since its inception. Therefore, there is important not underestimate the choice of operating parameters. The article describes an optimization procedure for choice of cost-effective operational parameters for a simple double pipe heat exchanger by using CFD software and the subsequent proposal to modify its design for more economical operation.

  7. Optimization principle of operating parameters of heat exchanger by using CFD simulation

    Directory of Open Access Journals (Sweden)

    Mičieta Jozef

    2016-01-01

    Full Text Available Design of effective heat transfer devices and minimizing costs are desired sections in industry and they are important for both engineers and users due to the wide-scale use of heat exchangers. Traditional approach to design is based on iterative process in which is gradually changed design parameters, until a satisfactory solution is achieved. The design process of the heat exchanger is very dependent on the experience of the engineer, thereby the use of computational software is a major advantage in view of time. Determination of operating parameters of the heat exchanger and the subsequent estimation of operating costs have a major impact on the expected profitability of the device. There are on the one hand the material and production costs, which are immediately reflected in the cost of device. But on the other hand, there are somewhat hidden costs in view of economic operation of the heat exchanger. The economic balance of operation significantly affects the technical solution and accompanies the design of the heat exchanger since its inception. Therefore, there is important not underestimate the choice of operating parameters. The article describes an optimization procedure for choice of cost-effective operational parameters for a simple double pipe heat exchanger by using CFD software and the subsequent proposal to modify its design for more economical operation.

  8. Temporal evolution of the spectral lines emission and temperatures in laser induced plasmas through characteristic parameters

    Energy Technology Data Exchange (ETDEWEB)

    Bredice, F., E-mail: faustob@ciop.unlp.edu.ar [Centro de Investigaciones Ópticas, P.O. Box 3 C. P.1897 Gonnet, La Plata (Argentina); Pacheco Martinez, P. [Grupo de Espectroscopía Óptica de Emisión y Láser, Universidad del Atlántico, Barranquilla (Colombia); Sánchez-Aké, C.; Villagrán-Muniz, M. [Laboratorio de Fotofísica, Centro de Ciencias Aplicadas y Desarrollo Tecnológico, Universidad Nacional Autónoma de México, Apartado Postal 70-186, México D.F. 04510 (Mexico)

    2015-05-01

    In this work, we propose an extended Boltzmann plot method to determine the usefulness of spectral lines for plasma parameter calculations. Based on the assumption that transient plasmas are under ideal conditions during an specific interval of time Δt, (i.e. thin, homogeneous and in local thermodynamic equilibrium (LTE)), the associated Boltzmann plots describe a surface in the space defined by the coordinates X = Energy, Y = Time and Z = ln (λ{sub jl}I{sub j}/g{sub j}A{sub jl}), where I{sub j} is the integrated intensity of the spectral line, g{sub j} is the statistical weight of the level j, λ{sub jl} is the wavelength of the considered line and A{sub jl} is its transition rate. In order to express the Boltzmann plot surface in terms of a reduced set of constants B{sub i}, and δ{sub i}, we developed as a power series of time, the logarithm of I{sub n}(t)/I{sub n}(t{sub 0}), where I{sub n}(t) is the integrated intensity of any spectral line at time t, and I{sub n}(t{sub 0}) at initial time. Moreover, the temporal evolution of the intensity of any spectral line and consequently the temperature of the plasma can be also expressed with these constants. The comparison of the temporal evolution of the line intensity calculated using these constants with their experimental values, can be used as a criterion for selecting useful lines in plasma analysis. Furthermore, this method can also be applied to determine self-absorption or enhancement of the spectral lines, to evaluate a possible departure of LTE, and to check or estimate the upper level energy value of any spectral line. An advantage of this method is that the value of these constants does not depend on the spectral response of the detection system, the uncertainty of the transition rates belonging to the analyzed spectral lines or any other time-independent parameters. In order to prove our method, we determined the constants B{sub i} and δ{sub i} and therefore the Boltzmann plot surface from the temporal

  9. The quiescent H-mode regime for high performance edge localized mode-stable operation in future burning plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Garofalo, A. M., E-mail: garofalo@fusion.gat.com; Burrell, K. H.; Meneghini, O.; Osborne, T. H.; Paz-Soldan, C.; Smith, S. P.; Snyder, P. B.; Turnbull, A. D. [General Atomics, P.O. Box 85608, San Diego, California 92186-5608 (United States); Eldon, D.; Grierson, B. A.; Solomon, W. M. [Princeton Plasma Physics Laboratory, P.O. Box 451, Princeton, New Jersey 08543-0451 (United States); Hanson, J. M. [Columbia University, 2960 Broadway, New York, New York 10027-6900 (United States); Holland, C. [University of California San Diego, 9500 Gilman Dr., La Jolla, California 92093-0417 (United States); Huijsmans, G. T. A.; Liu, F.; Loarte, A. [ITER Organization, Route de Vinon sur Verdon, 13067 St Paul Lez Durance (France); Zeng, L. [University of California Los Angeles, P.O. Box 957099, Los Angeles, California 90095-7099 (United States)

    2015-05-15

    For the first time, DIII-D experiments have achieved stationary quiescent H-mode (QH-mode) operation for many energy confinement times at simultaneous ITER-relevant values of beta, confinement, and safety factor, in an ITER-like shape. QH-mode provides excellent energy confinement, even at very low plasma rotation, while operating without edge localized modes (ELMs) and with strong impurity transport via the benign edge harmonic oscillation (EHO). By tailoring the plasma shape to improve the edge stability, the QH-mode operating space has also been extended to densities exceeding 80% of the Greenwald limit, overcoming the long-standing low-density limit of QH-mode operation. In the theory, the density range over which the plasma encounters the kink-peeling boundary widens as the plasma cross-section shaping is increased, thus increasing the QH-mode density threshold. The DIII-D results are in excellent agreement with these predictions, and nonlinear magnetohydrodynamic analysis of reconstructed QH-mode equilibria shows unstable low n kink-peeling modes growing to a saturated level, consistent with the theoretical picture of the EHO. Furthermore, high density operation in the QH-mode regime has opened a path to a new, previously predicted region of parameter space, named “Super H-mode” because it is characterized by very high pedestals that can be more than a factor of two above the peeling-ballooning stability limit for similar ELMing H-mode discharges at the same density.

  10. Non-boronized compared with boronized operation of ASDEX Upgrade with full-tungsten plasma facing components

    Science.gov (United States)

    Kallenbach, A.; Dux, R.; Mayer, M.; Neu, R.; Pütterich, T.; Bobkov, V.; Fuchs, J. C.; Eich, T.; Giannone, L.; Gruber, O.; Herrmann, A.; Horton, L. D.; Maggi, C. F.; Meister, H.; Müller, H. W.; Rohde, V.; Sips, A.; Stäbler, A.; Stober, J.; ASDEX Upgrade Team

    2009-04-01

    After completion of the tungsten coating of all plasma facing components, ASDEX Upgrade has been operated without boronization for 1 1/2 experimental campaigns. This has allowed the study of fuel retention under conditions of relatively low D co-deposition with low-Z impurities as well as the operational space of a full-tungsten device for the unfavourable condition of a relatively high intrinsic impurity level. Restrictions in operation were caused by the central accumulation of tungsten in combination with density peaking, resulting in H-L backtransitions induced by too low separatrix power flux. Most important control parameters have been found to be the central heating power, as delivered predominantly by ECRH, and the ELM frequency, most easily controlled by gas puffing. Generally, ELMs exhibit a positive impact, with the effect of impurity flushing out of the pedestal region overbalancing the ELM-induced W source. The restrictions of plasma operation in the unboronized W machine occurred predominantly under low or medium power conditions. Under medium-high power conditions, stable operation with virtually no difference between boronized and unboronized discharges was achieved. Due to the reduced intrinsic radiation with boronization and the limited power handling capability of VPS coated divertor tiles (≈10 MW m-2), boronized operation at high heating powers was possible only with radiative cooling. To enable this, a previously developed feedback system using (thermo-)electric current measurements as approximate sensor for the divertor power flux was introduced into the standard AUG operation. To avoid the problems with reduced ELM frequency due to core plasma radiation, nitrogen was selected as radiating species since its radiative characteristic peaks at lower electron temperatures in comparison with Ne and Ar, favouring SOL and divertor radiative losses. Nitrogen seeding resulted not only in the desired divertor power load reduction but also in improved

  11. Predictive two-dimensional scrape-off layer plasma transport modeling of phase-I operations of tokamak SST-1 using SOLPS5

    Science.gov (United States)

    Himabindu, M.; Tyagi, Anil; Sharma, Devendra; Deshpande, Shishir P.; Bonnin, Xavier

    2014-02-01

    Computational analysis of coupled plasma and neutral transport in the Scrape-Off Layer (SOL) region of the Steady-State Superconducting Tokamak (SST-1) is done using SOLPS for Phase-I of double-null divertor plasma operations. An optimum set of plasma parameters is explored computationally for the first phase operations with the central objective of achieving an effective control over particle and power exhaust. While the transport of plasma species is treated using a fluid model in the B2.5 code, a full kinetic description is provided by the EIRENE code for the neutral particle transport in a realistic geometry. Cases with and without external gas puffing are analyzed for finding regimes where an effective control of plasma operations can be exercised by controlling the SOL plasma conditions over a range of heating powers. In the desired parameter range, a reasonable neutral penetration across the SOL is observed, capable of causing a variation of up to 15% of the total input power, in the power deposited on the divertors. Our computational characterization of the SOL plasma with input power 1 MW and lower hybrid current drive, for the separatrix density up to 1019 m-3, indicates that there will be access to high recycling operations producing reduction in the temperature and the peak heat flux at the divertor targets. This indicates that a control of the core plasma density and temperature would be achievable. A power balance analysis done using the kinetic neutral transport code EIRENE indicates about 60%-75% of the total power diverted to the targets, providing quantitative estimates for the relative power loading of the targets and the rest of the plasma facing components.

  12. Typical Profiles and Distributions of Plasma and Magnetic Field Parameters in Magnetic Clouds at 1 AU

    Science.gov (United States)

    Rodriguez, L.; Masías-Meza, J. J.; Dasso, S.; Démoulin, P.; Zhukov, A. N.; Gulisano, A. M.; Mierla, M.; Kilpua, E.; West, M.; Lacatus, D.; Paraschiv, A.; Janvier, M.

    2016-08-01

    Magnetic clouds (MCs) are a subset of interplanetary coronal mass ejections (ICMEs). They are important because of their simple internal magnetic field configuration, which resembles a magnetic flux rope, and because they represent one of the most geoeffective types of solar transients. In this study, we analyze their internal structure using a superposed epoch method on 63 events observed at L1 by the Advance Composition Explorer (ACE), between 1998 and 2006. In this way, we obtain an average profile for each plasma and magnetic field parameter at each point of the cloud. Furthermore, we take a fixed time-window upstream and downstream from the MC to also sample the regions preceding the cloud and the wake trailing it. We then perform a detailed analysis of the internal characteristics of the clouds and their surrounding solar wind environments. We find that the parameters studied are compatible with log-normal distribution functions. The plasma β and the level of fluctuations in the magnetic field vector are the best parameters to define the boundaries of MCs. We find that one third of the events shows a peak in plasma density close to the trailing edge of the flux ropes. We provide several possible explanations for this result and investigate if the density peak is of a solar origin ( e.g. erupting prominence material) or formed during the magnetic cloud travel from the Sun to 1 AU. The most plausible explanation is the compression due to a fast overtaking flow, coming from a coronal hole located to the east of the solar source region of the magnetic cloud.

  13. Penentuan Efektifitas Oksitetrasiklin Melalui Parameter Farmakokinetik/farmakodinamik pada Plasma dan Jaringan Ayam Broiler

    Directory of Open Access Journals (Sweden)

    Agustina Dwi Wijayanti

    2010-06-01

    Full Text Available A study was conducted to determine the effectiveness of oxytetracycline on the basis of itspharmacokinetic/pharmacodynamic (PK/PD parameters in the plasma and tissues of broiler following a50 mg/kg single dose of intravenous administration. The male broiler were injected with oxytetracycline attarsal medial venous. The blood, liver, kidney and abdominal muscle were collected at 14 points of timesamplings. Blood was centrifuged to obtain plasma and all tissues were extracted with Mc Ilvine buffer.Drug concentration in samples was determined by High Performance Liquid Chromatography (HPLCusing AOAC standard reference for tetracycline. The pharmacokinetic parameters of oxytetracycline werecalculated using non compartment method. The results were as follows. For plasma: the AUC was 790,615,5 ?g/mL minute , Clearance was 63,242 mL/min/kg bb, Tmax/Cmax was 1 minute/0,7 ?g/mL, T1/2elimination was 6,4, hours, Vd was 37 L/kg. For liver ; AUC was 36418,89, minute , Tmax/Cmax was 16hours/17,15 ?g/g, and T1/2 elimination was 24,5, hours. For kidney; AUC6808,41 ?g/g minute , Tmax/Cmax 1 minute/16,73 ?g/g, , T1/2 elimination was 11,55 hours. For muscle; AUC was 3502 ?g/g minute,Tmax/Cmax was 1 minute/2,58 ?g/g, T1/2 elimination was 167,39 hours. The ratio of AUC/MIC inplasma and tissues appeared to a good pharmacokinetic/pharmacodynamic parameter to determine theeffectiveness of oxytetracycline.

  14. Post-operative corticosterone levels in plasma and feces of mice subjected to permanent catheterization and automated blood sampling.

    Science.gov (United States)

    Sundbom, Renée; Jacobsen, Kirsten R; Kalliokoski, Otto; Hau, Jann; Abelson, Klas S P

    2011-01-01

    This study investigated the effects of surgical placement of permanent arterial catheters on plasma corticosterone levels, fecal corticosterone excretion and body weight in male BALB/c/Sca mice. In addition, the effects of voluntarily ingested buprenorphine in doses of 0.5 and 1.0 mg/kg body weight on these parameters were studied. A catheter was placed in the carotid artery during isoflurane anesthesia. Immediately after surgery, the mice were connected to an AccuSampler® μ and blood samples for plasma corticosterone quantification were collected automatically during the first 24 h postoperatively. All fecal boli produced 24 h before and 24 h after surgery were collected for fecal corticosterone excretion measures and the pre- and post-operative body weights were registered. Plasma corticosterone levels were in the range of 150-300 ng/ml after the surgical procedure and the body weight was significantly lower 24 h after surgery compared to its pre-operative value. Contrary to what was expected, the total fecal corticosterone excretion was significantly reduced 24 h after surgery, as was the defecation. Buprenorphine treatment significantly lowered the plasma corticosterone levels, but had no effect on fecal corticosterone excretion or body weight change. It was concluded that surgical placement of an arterial catheter induces a significant stress response, as judged by its effect on plasma corticosterone and body weight. Voluntary ingestion of buprenorphine improved postoperative recovery by lowering plasma corticosterone concentrations. Neither fecal corticosterone excretion nor body weight change seems suitable for postoperative stress assessment in mice in the present experimental setup.

  15. Selenium, copper and zinc in seminal plasma of men with varicocele, relationship with seminal parameters.

    Science.gov (United States)

    Camejo, María Isabel; Abdala, Lyzeth; Vivas-Acevedo, Giovanny; Lozano-Hernández, Ricardo; Angeli-Greaves, Miriam; Greaves, Eduardo D

    2011-12-01

    Varicocele has been associated with decrease in seminal parameters. Selenium (Se), copper (Cu), and zinc (Zn) are trace elements essential for normal spermatogenesis of mammals and play a critical role as antioxidant defense system enzymes. Se, Cu, and Zn are associated with sperm quality in fertile and infertile men. However, there is little information about Se, Cu, and Zn concentrations in semen in patients with varicocele and its association with seminal parameters. The purpose of this study was to determine the concentrations of Se, Cu, and Zn in semen of patients with varicocele and the relationship with seminal parameters. Total Reflection X-Ray Fluorescence was used for the fist time in the seminal fluid analysis. The concentration of selenium in men with varicocele was smaller than the normozoospermic group, while no differences were observed for both concentrations of zinc and copper. A significant positive correlation between zinc and selenium concentration was observed. Selenium in seminal plasma correlates with a good spermatozoa concentrations, motility, and morphology. Additionally, a significant positive correlation was observed between zinc levels and sperm count. In conclusion, a decrease in selenium concentration was associated with detriment of seminal parameters. A study should be conducted to evaluate the benefits of both zinc and selenium supplementation to improve seminal parameters in patients with varicocele.

  16. Integrated micro-plasmas in silicon operating in helium

    CERN Document Server

    Dussart, Remi; Lefaucheux, P; Dufour, Thierry; Kulsreshath, M; Mandra, Monali; Tillocher, Thomas; Aubry, O; Dozias, S; Ranson, P; Goeckner, M

    2016-01-01

    Microplasma arrays operating in helium in a DC regime have been produced in silicon microre-actors. Cathode boundary layer (CBL) type microdevices were elaborated using clean room facilities and semiconductor processing techniques. Ignition of the micro-discharge arrays having either 50 or 100 m diameter cavities was studied. Two different structures (isotropically etched or anisotropically etched cavity) and various conditions (the two different voltage polarities, pressures etc.) were investigated. 100 microdis-charges of 50 m diameter could be ignited in parallel at 1000 torr. At high current, some parasitic and transient sparks appeared at the edge of the sample. When the polarization was reversed (cathode side corresponding the opened electrode), more current was needed to light all the microdischarges. A thermally affected zone around the hole on the anode side was obtained after operation.

  17. Optimum plasma grid bias for a negative hydrogen ion source operation with Cs

    Energy Technology Data Exchange (ETDEWEB)

    Bacal, Marthe, E-mail: marthe.bacal@lpp.polytechnique.fr [UPMC, LPP, Ecole Polytechnique, UMR CNRS 7648, Palaiseau (France); Sasao, Mamiko [R& D Promotion Organization, Doshisha University, Kamigyoku, Kyoto 602-8580 (Japan); Wada, Motoi [School of Science and Engineering, Doshisha University, Kyotonabe, Kyoto 610-0321 (Japan); McAdams, Roy [CCFE, Culham Science Center, Abingdon, Oxfordshire 0X14 3DB (United Kingdom)

    2016-02-15

    The functions of a biased plasma grid of a negative hydrogen (H{sup −}) ion source for both pure volume and Cs seeded operations are reexamined. Proper control of the plasma grid bias in pure volume sources yields: enhancement of the extracted negative ion current, reduction of the co-extracted electron current, flattening of the spatial distribution of plasma potential across the filter magnetic field, change in recycling from hydrogen atomic/molecular ions to atomic/molecular neutrals, and enhanced concentration of H{sup −} ions near the plasma grid. These functions are maintained in the sources seeded with Cs with additional direct emission of negative ions under positive ion and neutral hydrogen bombardment onto the plasma electrode.

  18. Current distribution measurements inside an electromagnetic plasma gun operated in a gas-puff mode

    OpenAIRE

    Poehlmann, Flavio R.; Cappelli, Mark A.; Rieker, Gregory B.

    2010-01-01

    Measurements are presented of the time-dependent current distribution inside a coaxial electromagnetic plasma gun. The measurements are carried out using an array of six axially distributed dual-Rogowski coils in a balanced circuit configuration. The radial current distributions indicate that operation in the gas-puff mode, i.e., the mode in which the electrode voltage is applied before injection of the gas, results in a stationary ionization front consistent with the presence of a plasma def...

  19. Optimization of basic parameters of cyclic operation of underground gas storages

    Directory of Open Access Journals (Sweden)

    Віктор Олександрович Заєць

    2015-04-01

    Full Text Available The problem of optimization of process parameters of cyclic operation of underground gas storages in gas mode is determined in the article. The target function is defined, expressing necessary capacity of compressor station for gas injection in the storage. Its minimization will find the necessary technological parameters, such as flow and reservoir pressure change over time. Limitations and target function are reduced to a linear form. Solution of problems is made by the simplex method

  20. APPLICATION DIMENSIONAL AND SIMILARITY THEORY IN DETERMINING THE PARAMETERS AND OPERATING MODES OF SOIL CULTIVATING MACHINES

    Directory of Open Access Journals (Sweden)

    Shhirov V. N.

    2015-06-01

    Full Text Available The article presents a study of parameters and modes of operation of machines for soil cultivation. In determining the parameters and modes of operation of machinery for tillage we have applied the theory of similarity and dimensions of physical quantities. We have obtained the regularities of disclosing the relationship of the parameters from the medium to the energy characteristics of the process. As the initial data we used test protocols of machines for soil cultivation (Central - Black Earth, Kubanskaya, Sibirskaya, of North - Caucasion MIS, RosNIITiM : KPI - 3.8, AРC - 3.9, AKV - 4, AKM - 6 - V, AMP - 4 APC - 4 A, AРC - 10 APR - 4.4, APU - 6.5 APSH - 6 , CNC - 6.0, CSТ - 3.8, APC - 4. We defined the formula оf dimension parameters and modes of operation of machines for soil cultivation and properties of soil (traction resistance, depth, width, speed, hardness of the soil, acceleration. Based on dimension theory we have received similarity criteria. Based on the correlation analysis and the least squares method we determined the nature of addiction and the coefficients for it. We have also received a graph for determining the operating modes and parameters of machines for soil cultivation

  1. Modal Parameters from a Wind Turbine Wing by Operational Modal Analysis

    DEFF Research Database (Denmark)

    Herlufsen, H.; Møller, N.; Brincker, Rune;

    2002-01-01

    Operational Modal Analysis also known as Ambient Modal Analysis has an increasing interest in mechanical engineering. Especially on big structures where the excitation and not less important the determination of the forces is most often a problem. In a structure like a wind turbine wing where...... the modes occur both close in frequency and bidirectional the Ambient excitation has big advantages. In this paper modal parameters are identified from the wing by operational modal analysis. For the parameter identification both parametric and non-parametric techniques are used. Advantages...

  2. The influence of operational parameters and feed preparation in a convective batch ribbon powder mixer

    OpenAIRE

    Yeow ST; Shahar A; Abdul Aziz N; Anuar MS; Yusof YA; Taip FS

    2011-01-01

    Sin Tung Yeow, Asnawi Shahar, Norashikin Abdul Aziz, Mohd Shamsul Anuar, Yus Aniza Yusof, Farah Saleena TaipDepartment of Process and Food Engineering, Faculty of Engineering, Universiti Putra Malaysia, Selangor, MalaysiaPurpose: To investigate the effect of feed preparation characteristics and operational parameters on mixing homogeneity in a convective batch ribbon mixer.Methods: Lactose 100M, lactose 200M, ascorbic acid, and zinc oxide powders were used for the mixing study. Operational pa...

  3. Influence of geometrical parameters on performance of plasma synthetic jet actuator

    Science.gov (United States)

    Zong, Hao-hua; Wu, Yun; Jia, Min; Song, Hui-min; Liang, Hua; Li, Ying-hong; Zhang, Zhi-bo

    2016-01-01

    Plasma synthetic jet actuator (PSJA) has shown wide and promising application prospects in a high speed flow control field, due to its rapid response, high exhaust velocity, and non-moving components. In this paper, the total pressure profile of a plasma synthetic jet (PSJ) is measured and a new method is developed to evaluate the pulsed thrust of the PSJA. The influence of geometrical parameters including the electrode distance, the orifice diameter, and the throat length on PSJA performance is analyzed based on the pulsed thrust, the discharge characteristics, and the schlieren images. When varying the electrode distance, the dominant factor determining the jet intensity is the heating volume instead of the discharge energy. For the arc discharge, the electrode distance should be extended to increase both the jet velocity and the jet duration time. The design of the orifice diameter should be based on the controlled flow field. A large orifice diameter produces a strong perturbation with short time duration, while a small orifice diameter induces a lasting jet with low mass flux. In order to obtain better high frequency performance, the throat length should be shortened on the condition that the structural strength of the PSJA is maintained, while there is almost no influence of the throat length on the single cycle performance of the PSJA. Once the discharge energy is fixed, the pulsed thrust remains almost unchanged with different orifice diameters and throat lengths. These three geometrical parameters are independent to some extent and can be optimized separately.

  4. Plasma arc cutting optimization parameters for aluminum alloy with two thickness by using Taguchi method

    Science.gov (United States)

    Abdulnasser, B.; Bhuvenesh, R.

    2016-07-01

    Manufacturing companies define the qualities of thermal removing process based on the dimension and physical appearance of the cutting material surface. The surface roughness of the cutting area for the material and the material removal rate being removed during the manual plasma arc cutting process were importantly considered. Plasma arc cutter machine model PS-100 was used to cut the specimens made from aluminium alloy 1100 manually based on the selected parameters setting. Two different thicknesses of specimens, 3mm and 6mm were used. The material removal rate (MRR) was measured by determining the difference between the weight of specimens before and after the cutting process. The surface roughness (Ra) was measured by using MITUTOYO CS-3100 machine and analysis was conducted to determine the average roughness (Ra) value, Taguchi method was utilized as an experimental layout to obtain MRR and Ra values. The results indicate that the current and cutting speed is the most significant parameters, followed by the arc gap for both rate of material removal and surface roughness.

  5. Performance Testing of Suspension Plasma Sprayed Thermal Barrier Coatings Produced with Varied Suspension Parameters

    Directory of Open Access Journals (Sweden)

    Nicholas Curry

    2015-07-01

    Full Text Available Suspension plasma spraying has become an emerging technology for the production of thermal barrier coatings for the gas turbine industry. Presently, though commercial systems for coating production are available, coatings remain in the development stage. Suitable suspension parameters for coating production remain an outstanding question and the influence of suspension properties on the final coatings is not well known. For this study, a number of suspensions were produced with varied solid loadings, powder size distributions and solvents. Suspensions were sprayed onto superalloy substrates coated with high velocity air fuel (HVAF -sprayed bond coats. Plasma spray parameters were selected to generate columnar structures based on previous experiments and were maintained at constant to discover the influence of the suspension behavior on coating microstructures. Testing of the produced thermal barrier coating (TBC systems has included thermal cyclic fatigue testing and thermal conductivity analysis. Pore size distribution has been characterized by mercury infiltration porosimetry. Results show a strong influence of suspension viscosity and surface tension on the microstructure of the produced coatings.

  6. Relevant parameter space and stability of spherical tokamaks with a plasma center column

    Science.gov (United States)

    Lampugnani, L. G.; Garcia-Martinez, P. L.; Farengo, R.

    2017-02-01

    A spherical tokamak (ST) with a plasma center column (PCC) can be formed inside a simply connected chamber via driven magnetic relaxation. From a practical perspective, the ST-PCC could overcome many difficulties associated with the material center column of the standard ST reactor design. Besides, the ST-PCC concept can be regarded as an advanced helicity injected device that would enable novel experiments on the key physics of magnetic relaxation and reconnection. This is because the concept includes not only a PCC but also a coaxial helicity injector (CHI). This combination implies an improved level of flexibility in the helicity injection scheme required for the formation and sustainment phases. In this work, the parameter space determining the magnetic structure of the ST-PCC equilibria is studied under the assumption of fully relaxed plasmas. In particular, it is shown that the effect of the external bias field of the PCC and the CHI essentially depends on a single parameter that measures the relative amount of flux of these two entities. The effect of plasma elongation on the safety factor profile and the stability to the tilt mode are also analyzed. In the first part of this work, the stability of the system is explained in terms of the minimum energy principle, and relevant stability maps are constructed. While this picture provides an adequate insight into the underlying physics of the instability, it does not include the stabilizing effect of line-tying at the electrodes. In the second part, a dynamical stability analysis of the ST-PCC configurations, including the effect of line-tying, is performed by numerically solving the magnetohydrodynamic equations. A significant stability enhancement is observed when the PCC contains more than the 70% of the total external bias flux, and the elongation is not higher than two.

  7. Tritium inventory control during ITER operation under carbon plasma-facing components by nitrogen-based plasma chemistry: a review

    Science.gov (United States)

    Tabarés, F. L.

    2013-06-01

    In spite of being highly suited for advanced plasma performance operation of tokamaks, as demonstrated over at least two decades of fusion plasma research, carbon is not currently considered as an integrating element of the plasma-facing components (PFCs) for the active phase of ITER. The main reason preventing its use under the very challenging scenarios foreseen in this phase, with edge-localized modes delivering several tens of MW m-2 to the divertor target every second or less, is the existing concern about reaching the tritium inventory value of 1000 g used in safety assessments in a time shorter than the projected lifetime of the divertor materials eroded by the plasma, set at 3000 shots. Although several mechanisms of tritium trapping in carbon components have been identified, co-deposition of the carbon radicals arising from chemically eroded chlorofluorocarbons in remote areas appears to play a dominant role. Several possible ways to keep control of the tritium build-up during the full operation of ITER have been put forward, mostly based on the periodic removal of the co-deposits by chemical (thermo-oxidation, plasma chemistry) or physical (laser, flash lamps) methods. In this work, we review the techniques for the inhibition and removal of tritium-rich co-deposits based on the strong chemical reactivity of some N-bearing molecules with carbon. The integration of these techniques into a possible scheme for tritium inventory control in the active phase of ITER under carbon-based PFCs with minimum down-time is discussed and the existing caveats are addressed.

  8. OPTIMIZATION OF OPERATING PARAMETERS FOR EDM PROCESS BASED ON THE TAGUCHI METHOD AND ARTIFICIAL NEURAL NETWORK

    Directory of Open Access Journals (Sweden)

    A.Thillaivanan,

    2010-12-01

    Full Text Available In this paper the complexity of electrical discharge machining process which is very difficult to determine optimal cutting parameters for improving cutting performance has been reported. Optimization of operating parameters is an important step in machining, particularly for operating unconventional machiningprocedure like EDM. A suitable selection of machining parameters for the electrical discharge machining process relies heavily on the operators’ technologies and experience because of their numerous and diverse range. Machining parameters tables provided by the machine tool builder can not meet the operators’ requirements, since for anarbitrary desired machining time for a particular job, they do not provide the optimal machining conditions. An approach to determine parameters setting is proposed. Based on the Taguchi parameter design method and the analysis of variance, the significant factors affecting the machining performance such as total machining time, oversize and taper for a hole machined by EDM process, are determined.Artificial neural networks are highly flexible modeling tools with an ability to learn the mapping between input variables and output feature spaces. The superiority of using artificial neural networks inmodeling machining processes make easier to model the EDM process with dimensional input and output spaces. On the basis of the developed neural network model, for a required total machining time, oversize and taper the corresponding process parameters to be set in EDM by using the developed and trained ANN are determined.

  9. MULTI-PARAMETER TIKHONOV REGULARIZATION FOR LINEAR ILL-POSED OPERATOR EQUATIONS

    Institute of Scientific and Technical Information of China (English)

    Zhongying Chen; Yao Lu; Yuesheng Xu; Hongqi Yang

    2008-01-01

    We consider solving linear ill-posed operator equations.Based on a multi-scale decomposition for the solution space,we propose a multi-parameter regularization for solving the equations.We establish weak and strong convergence theorems for the multi-parameter regularization solution.In particular,based on the eigenfunction decomposition,we develop a posteriori choice strategy for multi-parameters which gives a regularization solution with the optimal error bound.Several practical choices of multi-parameters are proposed.We also present numerical experiments to demonstrate the outperformance of the multiparameter regularization over the single parameter regularization.Mathematics subject classification:47A52.

  10. Observations and implications of gap closure in plasma opening switch operation

    Science.gov (United States)

    Goyer, John R.; Kortbawi, David

    1994-09-01

    Plasma opening switches are believed to develop voltage through opening and magnetically insulating a gap formed in plasma injected between two conducting electrodes. Data will be presented to show that a relatively simple assumption about the behavior of this gap suffices to describe the overall operation of the switch. Specifically, the observed increase, then decrease, of operational voltage as a function of conduction time can be accounted for by the switch gap linearly decreasing with conduction time, while the conducted current increases. In addition to presentation of data to demonstrate this collapse, analysis is performed to couple the gap history to the voltage predicted for the switch, and to optimize this latter quantity.

  11. Operational characteristics and non-inductive plasmas on NSTX-U

    Science.gov (United States)

    Mueller, Dennis

    2016-10-01

    Start-up and ramp-up of NSTX-U plasmas with nearly full solenoid pre-charge required higher loop voltage than on NSTX in agreement with modeling. NSTX-U has operated with a plasma current (Ip) of 0.65 MA at a toroidal field (BT) of 0.63 T for 2s in L-Mode. These plasmas allowed for the initial investigation of error field correction which found a difference between correction during Ip flattop and during ramp-up. Plasma control using feedback on the X-Point locations or the X-point height and outer strike point locations is routinely used. Because an ST does not have a single coil set that controls the inner gap, it was challenging to control the time at which the plasma diverted. A novel approach was used to trade off accuracy on the outer plasma shape to achieve a reproducible inner gap. These control tools allowed study of ELMy H-mode operation at Ip = 1 MA with boronized walls. A major long-term goal for NSTX-U is totally non-inductive operation. The plan calls for initiating the plasma with coaxial helicity injection (CHI) heatied by ECH, then current drive and heating by HHFW and NBI. CHI will be used in the new geometry to demonstrate results comparable to NSTX and provide information to inform plans to upgrade the available voltage from 1.65 to 2 kV next year. Low Ip plasmas will be used to study the dependence of current drive on neutral beam voltage and injection angle. Work Supported by U.S.D.O.E. Contract No. DE-AC02-09CH11466.

  12. GeV electron acceleration by a Gaussian field laser with effect of beam width parameter in magnetized plasma

    Science.gov (United States)

    Ghotra, Harjit Singh; Kant, Niti

    2017-01-01

    Electron acceleration due to a circularly polarized (CP) Gaussian laser field has been investigated theoretically in magnetized plasma. A Gaussian laser beam possesses trapping forces on electrons during its propagation through plasma. A single particle simulation indicates a resonant enhancement of electron acceleration with a Gaussian laser beam. The plasma is magnetized with an axial magnetic field in same direction as that of laser beam propagation. The dependence of laser beam width parameter on electron energy gain with propagation distance has been presented graphically for different values of laser intensity. Electron energy gain is relatively high where the laser beam parameter is at its minimum value. Enhanced energy gain of the order of GeV is reported with magnetic field under 20 MG in plasma. It is also seen that the axial magnetic field maintains the electron acceleration for large propagation distance even with an increasing beam width parameter.

  13. Relationship between Lipids Levels of Serum and Seminal Plasma and Semen Parameters in 631 Chinese Subfertile Men.

    Directory of Open Access Journals (Sweden)

    Jin-Chun Lu

    Full Text Available This prospective study was designed to investigate the relationship between lipids levels in both serum and seminal plasma and semen parameters.631 subfertile men were enrolled. Their obesity-associated markers were measured, and semen parameters were analyzed. Also, seminal plasma and serum TC, TG, HDL and LDL and serum FFA, FSH, LH, total testosterone (TT, estradiol (E2 and SHBG levels were detected.Seminal plasma and serum TG, TC and LDL levels were positively related to age. Serum TC, TG and LDL were positively related to obesity-associated markers (P < 0.001, while only seminal plasma TG was positively related to them (P < 0.05. For lipids levels in serum and seminal plasma, only TG level had slightly positive correlation between them (r = 0.081, P = 0.042. There was no significant correlation between serum lipids levels and semen parameters. However, seminal plasma TG, TC, LDL and HDL levels were negatively related to one or several semen parameters, including semen volume (SV, sperm concentration (SC, total sperm count (TSC, sperm motility, progressive motility (PR and total normal-progressively motile sperm counts (TNPMS. Moreover, seminal plasma TG, TC, LDL and HDL levels in patients with oligospermatism, asthenospermia and teratozoospermia were higher than those with normal sperm concentration, motility or morphology. After adjusting age and serum LH, FSH, TT, E2 and SHBG levels, linear regression analysis showed that SV was still significantly correlated with seminal plasma LDL (P = 0.012, both of SC and TSC with seminal plasma HDL (P = 0.028 and 0.002, and both of PR and sperm motility with seminal plasma TC (P = 0.012 and 0.051.The abnormal metabolism of lipids in male reproductive system may contribute to male factor infertility.

  14. Effects of operation temperature on thermal expansion and main parameters of radial ball bearings

    Directory of Open Access Journals (Sweden)

    Mitrović Radivoje M.

    2015-01-01

    Full Text Available The research of influence of operation temperature on the thermal expansion and main parameters of radial ball bearings is presented in this paper. The main bearing parameters are identified in accordance with the increasing requests concerning stability and load capacity. A series of Finite Element Analyses is performed for quasi-static analysis of all identified bearing parameters during contact period in referent temperature. Then, the dependence of bearing material characteristics on the operation temperature is discussed. Few series of Finite Element Analyses are performed for a particular radial ball bearing type, with characteristics in accordance with manufacturer specifications, for several operation temperatures. These two problems analyses include consideration of relation between the initial radial clearance, thermal expansion strains and contact deformations of the parts of the bearing assembly. The results for radial ball bearing parameters are monitored during a ball contact period for different temperatures and the appropriate discussion and conclusions are given. The conclusions about the contribution of developed procedure in defining the optimum operation temperature range are shown. [Projekat Ministarstva nauke Republike Srbije, br. TR 35029 i br. OI 174001

  15. Influence of operating parameters on product size obtained from an EVT No. 35 test mill

    Energy Technology Data Exchange (ETDEWEB)

    Borthwick, I.R.

    1984-01-01

    The broad objective is to undertake fundamental studies into the milling and drying of brown coal to obtain sufficient understanding of the processes involved to enable existing and proposed mill designs to be assessed and improved. The objective of the work reported here is to determine the effect of operating parameters and product moisture content on product size in a small scale EVT mill.

  16. INFLUENCE OF TECHNOLOGICAL PARAMETERS OF CROSS-COUNTRY GAS PIPELINE ON OPERATIONAL INDICES OF COMPRESSOR STATION

    Directory of Open Access Journals (Sweden)

    A. A. Abrazovsky

    2014-01-01

    Full Text Available The paper contains an analysis that reveals an influence of technological parameters of a cross-country pipeline on operational indices of a compressor station. An actual dependence of the gas pipeline capacity and consumed power of the compressor station and real indices of power efficiency of gas compressor units have been determined in the paper.

  17. Reduction of Erosion Wear of Mean Pressure Cylinder of Steam Turbines Operating Beyond Critical Parameters

    Directory of Open Access Journals (Sweden)

    V. P. Kascheev

    2009-01-01

    Full Text Available The paper considers problems leading to erosion wear of flowing part of a mean pressure turbine cylinder operating beyond critical parameters. Explanation of erosion wear of flowing part of a mean pressure turbine cylinder which is proved in practice and recommendations for wear reduction are given in the paper

  18. DETERMINATION OF OPERATING FIELDS OF TOLERANCES OF HYDRAULIC SYSTEMS PARAMETERS FOR AIRCRAFT BOARD COMPUTER COMPLEX

    Directory of Open Access Journals (Sweden)

    2016-01-01

    Full Text Available To determine the operating fields of the tolerances of hydraulic systems parameters for various conditions of work and phases of flight given mathematical relationships and the results obtained in Mathcad in analytical form for the board computer system.

  19. Quantum Logic Operation with Single Trapped Ion Without Limitation of Lamb-Dicke Parameter

    Institute of Scientific and Technical Information of China (English)

    ZHANG Rong; ZHU Shi-Qun

    2003-01-01

    By applying the nonlinear interaction between internal and external degrees of a trapped ion with theassistance of two pairs or three pairs of laser beams that are perpendicular to each other, the realization of quantumlogic operation without the limitation on the Lamb-Dicke parameter can be achieved when the lasers are tuned to thecarrier.

  20. A path to stable low-torque plasma operation in ITER with test blanket modules

    Science.gov (United States)

    Lanctot, M. J.; Snipes, J. A.; Reimerdes, H.; Paz-Soldan, C.; Logan, N.; Hanson, J. M.; Buttery, R. J.; deGrassie, J. S.; Garofalo, A. M.; Gray, T. K.; Grierson, B. A.; King, J. D.; Kramer, G. J.; La Haye, R. J.; Pace, D. C.; Park, J.-K.; Salmi, A.; Shiraki, D.; Strait, E. J.; Solomon, W. M.; Tala, T.; Van Zeeland, M. A.

    2017-03-01

    New experiments in the low-torque ITER Q  =  10 scenario on DIII-D demonstrate that n  =  1 magnetic fields from a single row of ex-vessel control coils enable operation at ITER performance metrics in the presence of applied non-axisymmetric magnetic fields from a test blanket module (TBM) mock-up coil. With n  =  1 compensation, operation below the ITER-equivalent injected torque is successful at three times the ITER equivalent toroidal magnetic field ripple for a pair of TBMs in one equatorial port, whereas the uncompensated TBM field leads to rotation collapse, loss of H-mode and plasma current disruption. In companion experiments at high plasma beta, where the n  =  1 plasma response is enhanced, uncorrected TBM fields degrade energy confinement and the plasma angular momentum while increasing fast ion losses; however, disruptions are not routinely encountered owing to increased levels of injected neutral beam torque. In this regime, n  =  1 field compensation leads to recovery of a dominant fraction of the TBM-induced plasma pressure and rotation degradation, and an 80% reduction in the heat load to the first wall. These results show that the n  =  1 plasma response plays a dominant role in determining plasma stability, and that n  =  1 field compensation alone not only recovers most of the impact on plasma performance of the TBM, but also protects the first wall from potentially damaging heat flux. Despite these benefits, plasma rotation braking from the TBM fields cannot be fully recovered using standard error field control. Given the uncertainty in extrapolation of these results to the ITER configuration, it is prudent to design the TBMs with as low a ferromagnetic mass as possible without jeopardizing the TBM mission.

  1. Improvement of strategies and parameters for multi-axis laser cladding operations

    Science.gov (United States)

    Calleja, A.; Tabernero, I.; Fernández, A.; Celaya, A.; Lamikiz, A.; López de Lacalle, L. N.

    2014-05-01

    The application of laser cladding technology is nowadays widely extended in several industrial sectors due to its advantages for high added value parts direct manufacturing and repairing. At the moment, the process is mainly applied to 3 axis or 3+2 axis strategies, being numerous works focused on the obtainment of process parameters. Some industrial application imposes the use of 5 continuous axis kinematics to perform complex parts. This fact requires new processes design and new strategies for this type of operations. The presented work evaluates the steps to be followed before accomplishing 5 axis laser cladding operations. First, the design of a test part for the experimental tests is carried out, taking into account the machine kinematics. Afterwards, both, the process control parameters and the tool path strategies are analyzed. Finally, the optimization of process parameter and strategies is presented. Therefore, the work represents a useful tool for the industrial application of 5 axis laser cladding.

  2. Nuclear magnetic resonance-based metabonomics reveals strong sex effect on plasma metabolism in 17-year-old Scandinavians and correlation to retrospective infant plasma parameters.

    Science.gov (United States)

    Bertram, Hanne Christine; Duus, Jens Ø; Petersen, Bent O; Hoppe, Camilla; Larnkjaer, Anni; Schack-Nielsen, Lene; Mølgaard, Christian; Michaelsen, Kim F

    2009-07-01

    Nuclear magnetic resonance (NMR)-based metabonomics was carried out on plasma samples from a total of seventy-five 17-year-old Danes to investigate the impact of key parameters such as sex, height, weight, and body mass index on the plasma metabolite profile in a normal, healthy population. Principal component analysis identified sex to have a large impact on the NMR plasma metabolome, whereas no apparent effects of height, weight, and body mass index were found. Partial least square regression discriminant analysis and quantification of relative metabolite concentrations by integration of NMR signals revealed that the sex effect included differences in plasma lipoproteins (mainly high-density lipoprotein), glucose, choline, and amino acid content. Accordingly, the present study suggests a higher lipid synthesis in young women than young men and a higher protein turnover in young men compared with women. Data on plasma content of triglyceride, lipoprotein fractions, and cholesterol at an age of 9 months were available for selected individuals (n = 40); and partial least square regressions revealed correlations between these infant parameters and the NMR plasma metabolome at an age of 17 years. In conclusion, the present study demonstrates the feasibility of NMR-based metabonomics for obtaining a deeper insight into interindividual differences in metabolism and for exploring relationships between parameters measured early in life and metabolic status at a later stage.

  3. Relationships between organohalogen contaminants and blood plasma clinical–chemical parameters in chicks of three raptor species from Northern Norway

    DEFF Research Database (Denmark)

    Sonne, Christian; Bustnes, Jan Ove; Herzke, Dorte

    2010-01-01

    Organohalogen contaminants (OHCs) may affect various physiological parameters in birds including blood chemistry. We therefore examined blood plasma clinical-chemical parameters and OHCs in golden eagle, white-tailed eagle and goshawk chicks from Northern Norway. Correlation analyses on pooled da...

  4. Relation of Plasma Uric Acid Levels and the Lipid Parameters in Han and Uygur Ethnicity

    Institute of Scientific and Technical Information of China (English)

    Sun Yuping; Yao Hua; Yao Wenhai; Li Qing; You Lan; Wang Qiuyun; Jiang Yan

    2006-01-01

    Objectives Hyperuricemia is a common finding in hypertension and hyperlipidemia,they are all correlated to cardiovascular diseases. The aim of this study was to find the relationship of uric acid and plasma lipid parameters of Han and Uygur ethnicity in Xinjiang. Methods This cross-sectional health examination survey was based on a population random sample from the Urumchi, It included 1166 subjects aged from 20 to 70 years. Serum biochemical testing by Automatic Analyzer (HITACHI 7600-010).Results The uric acid in Han was higher than in Uygur(P< 0.05), men were higher than women in two ethnicities; For lipid parameters men were higher than women, in TG and HDL women were higher than in men in two ethnicity (P < 0.05). Serum uric acid was strongly related to serum triglycerides in Han as well as Uygur ethnicity ( P < 0.001); Compared with the normal group, UA, TG, CHOL, VLDL had ascending trend and HDL had descending trend (P <0.05 ) among groups in Han and Uygur ethnicity,especially Hyperuricemia-hypertriglyceridemia group,uric acid and most some lipid parameters was higher than Hyperuricemia and hypertriglyceridemia group,The prevalence of different groups in Han and Urgur was significantly different (P < 0.05). Conclusions This study shows that the UA and some lipid parameters are different in Han and Uygur ethnicity and show sexual difference; serum uric acid is markedly related to serum triglycerides; Hyperuricemia and hypertriglyceridemia show cooperated effect in uric acid and most lipid parameters. Considering the growing incidence of the potential link between hyperuricemia/hypertriglyceridemia and cardiovascular diseases, more emphasis should be put on the evolving prevalence of hyperuricemia and hypertriglyceridemia in Xinjiang.

  5. Preparation for the operation of ITER: EU study on the plasma control system

    Energy Technology Data Exchange (ETDEWEB)

    Cavinato, M., E-mail: mario.cavinato@f4e.europa.eu [Fusion for Energy, Barcelona (Spain); Ambrosino, G. [CREATE/ENEA/Euratom Association, Università di Napoli Federico II, Naples (Italy); Figini, L.; Granucci, G. [Associazione EURATOM-ENEA sulla Fusione, IFP-CNR, Via R. Cozzi 53, 20125 Milano (Italy); Gribov, Y. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul Lez Durance (France); Koechl, F. [Association EURATOM-ÖAW/ATI, Atominstitut, TU Wien, 1020 Vienna (Austria); Mattei, M. [CREATE/ENEA/Euratom Association, Seconda Università di Napoli, Naples (Italy); Parail, V. [Euratom/CCFE Fusion Association, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Pironti, A. [CREATE/ENEA/Euratom Association, Università di Napoli Federico II, Naples (Italy); Ricci, D. [Associazione EURATOM-ENEA sulla Fusione, IFP-CNR, Via R. Cozzi 53, 20125 Milano (Italy); Saibene, G.; Sartori, R. [Fusion for Energy, Barcelona (Spain); Zabeo, L. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul Lez Durance (France)

    2014-10-15

    In view of the preparation for the operation of the ITER tokamak it is necessary to develop the plasma scenarios taking into account all engineering constraints coming from the plant and including a realistic control system. It is important to consider that, due to the high energy of ITER plasmas, much more stringent requirements are posed on the control of transients in order to avoid machine damage. Several activities are performed in the EU focusing on one side on the scenario optimization from a physics point of view and on the other side on the design and modeling of a realistic plasma control system driving the plasma configuration throughout the whole pulse and suitable for implementation on a real machine. The issues related to the computation of the control feed-forward component are addressed. In particular, the possibility to trigger a feed-forward component to solve controllability problems arising in the transitions from plasma L to H and H to L modes is studied in detail with the support of linear and non-linear simulations. A control strategy is designed and tested on non-linear simulations of the whole pulse, including linear and non-linear effects due to controller switching, plasma shape reconstruction and power supplies. The paper reports on the results of the studies performed and discuss the proposed design of the plasma control system.

  6. Relationship between Lipids Levels of Serum and Seminal Plasma and Semen Parameters in 631 Chinese Subfertile Men

    Science.gov (United States)

    Yao, Qi; Fan, Kai; Wang, Guo-Hong; Feng, Rui-Xiang; Liang, Yuan-Jiao; Chen, Li; Ge, Yi-Feng; Yao, Bing

    2016-01-01

    Objective This prospective study was designed to investigate the relationship between lipids levels in both serum and seminal plasma and semen parameters. Methods 631 subfertile men were enrolled. Their obesity-associated markers were measured, and semen parameters were analyzed. Also, seminal plasma and serum TC, TG, HDL and LDL and serum FFA, FSH, LH, total testosterone (TT), estradiol (E2) and SHBG levels were detected. Results Seminal plasma and serum TG, TC and LDL levels were positively related to age. Serum TC, TG and LDL were positively related to obesity-associated markers (P lipids levels in serum and seminal plasma, only TG level had slightly positive correlation between them (r = 0.081, P = 0.042). There was no significant correlation between serum lipids levels and semen parameters. However, seminal plasma TG, TC, LDL and HDL levels were negatively related to one or several semen parameters, including semen volume (SV), sperm concentration (SC), total sperm count (TSC), sperm motility, progressive motility (PR) and total normal-progressively motile sperm counts (TNPMS). Moreover, seminal plasma TG, TC, LDL and HDL levels in patients with oligospermatism, asthenospermia and teratozoospermia were higher than those with normal sperm concentration, motility or morphology. After adjusting age and serum LH, FSH, TT, E2 and SHBG levels, linear regression analysis showed that SV was still significantly correlated with seminal plasma LDL (P = 0.012), both of SC and TSC with seminal plasma HDL (P = 0.028 and 0.002), and both of PR and sperm motility with seminal plasma TC (P = 0.012 and 0.051). Conclusion The abnormal metabolism of lipids in male reproductive system may contribute to male factor infertility. PMID:26726884

  7. Impact of the Digital Coil Protection System and Plasma Shutdown Handler on NSTX-U Operations

    Science.gov (United States)

    Gerhardt, Stefan; Battaglia, D.; Boyer, M.; Erickson, K.; Mueller, D.; Myers, C.; Mueller, D.; Sabbagh, S. A.

    2016-10-01

    In order to prevent excessive forces on the NSTX-U vessel and coils, a digital coil protection system (DCPS) has been implemented. This system computes approximately 400 different forces/torques/stresses, and terminates the discharge if limits on those quantities are exceeded. It is desirable, however, to prevent these coil system trips from ever happening. Given that many of these limits would be reached during transients associated with disruptions, as ``discharge shutdown handler'' was coded in the plasma control system to automatically control the plasma shutdown. This is a state machine with five states, and a set of rules for transitioning between states. The first use of these systems during plasma operations on NSTX-U will be described, with a focus on operational experiences and directions for future improvements. Work Supported by U.S.D.O.E. Contract No. DE-AC02-09CH11466.

  8. Value as a parameter to consider in operational strategies for CSP plants

    Science.gov (United States)

    de Meyer, Oelof; Dinter, Frank; Govender, Saneshan

    2017-06-01

    This paper introduced a value parameter to consider when analyzing operational strategies for CSP plants. The electric system in South Africa, used as case study, is severely constrained with an influx of renewables in the early phase of deployment. The energy demand curve for the system is analyzed showing the total wind and solar photovoltaic contributions for winter and summer. Due to the intermittent nature and meteorological operating conditions of wind and solar photovoltaic plants, the value of CSP plants within the electric system is introduced. Analyzing CSP plants based on the value parameter alone will remain only a philosophical view. Currently there is no quantifiable measure to translate the philosophical view or subjective value and it solely remains the position of the stakeholder. By introducing three other parameters, Cost, Plant and System to a holistic representation of the Operating Strategies of generation plants, the Value parameter can be translated into a quantifiable measure. Utilizing the country's current procurement program as case study, CSP operating under the various PPA within the Bid Windows are analyzed. The Value Cost Plant System diagram developed is used to quantify the value parameter. This paper concluded that no value is obtained from CSP plants operating under the Bid Window 1 & 2 Power Purchase Agreement. However, by recognizing the dispatchability potential of CSP plants in Bid Window 3 & 3.5, the value of CSP in the electric system can be quantified utilizing Value Added Relationship VCPS-diagram. Similarly ancillary services to the system were analyzed. One of the relationships that have not yet been explored within the industry is an interdependent relationship. It was emphasized that the cost and value structure is shared between the plant and system. Although this relationship is functional when the plant and system belongs to the same entity, additional value is achieved by marginalizing the cost structure. A

  9. Feed gas humidity: a vital parameter affecting a cold atmospheric-pressure plasma jet and plasma-treated human skin cells

    Science.gov (United States)

    Winter, J.; Wende, K.; Masur, K.; Iseni, S.; Dünnbier, M.; Hammer, M. U.; Tresp, H.; Weltmann, K.-D.; Reuter, S.

    2013-07-01

    In this study, the effect of feed gas humidity on the reactive component generation of an atmospheric-pressure argon plasma jet and its effect on human skin cells are investigated. Feed gas humidity is identified as one key parameter that strongly influences stability and reproducibility of plasma medical studies. The plasma jet is investigated by absorption spectroscopy in the ultraviolet and infrared spectral region for its ozone production depending on the humidity concentration in the feed gas. By optical emission spectroscopy the dependence of present excited plasma species such as hydroxyl radicals, molecular nitrogen, argon and atomic oxygen on the feed gas humidity is investigated. As an interface layer between the plasma jet effluent and the biological cell, a buffer solution is treated and the hydrogen peroxide (H2O2) production is studied with two independent colorimetric assays as a function of humidity admixture to the feed gas. Ultimately, the effect of varying feed gas humidity on the cell viability of indirect plasma treated adherent HaCAT cells is investigated. The highest viability is found for the driest feed gas condition. Furthermore, this work shows answers for the relevance of unwanted—or intended—feed gas humidity in plasma medical experiments and their comparatively large relevance with respect to ambient humidity. The findings will lead to more reproducible experiments in the field of plasma medicine.

  10. Plasma polymers deposited in atmospheric pressure dielectric barrier discharges: Influence of process parameters on film properties

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, Katja, E-mail: k.fricke@inp-greifswald.de [Leibniz Institute for Plasma Science and Technology e.V. (INP Greifswald), Felix-Hausdorff-Str. 2, 17489 Greifswald (Germany); Girard-Lauriault, Pierre-Luc [Plasma Processing Laboratory, Department of Chemical Engineering, McGill University, 3610 rue University, Montreal, QC H3A 0C5 (Canada); Weltmann, Klaus-Dieter [Leibniz Institute for Plasma Science and Technology e.V. (INP Greifswald), Felix-Hausdorff-Str. 2, 17489 Greifswald (Germany); Wertheimer, Michael R. [Department of Engineering Physics, École Polytechnique de Montréal, Box 6079, Station Centre-Ville, Montreal, QC H3C 3A7 (Canada)

    2016-03-31

    We present results on the deposition of plasma polymer (PP) films in a dielectric barrier discharge system fed with mixtures of argon or nitrogen carrier gas plus different hydrocarbon precursors, where the latter possess different carbon-to-hydrogen ratios: CH{sub 4} < C{sub 2}H{sub 6} < C{sub 2}H{sub 4} = C{sub 3}H{sub 6} < C{sub 2}H{sub 2}. The influence of precursor gas mixture and flow rate, excitation frequency, and absorbed power on PP film compositions and properties has been investigated. The discharge was characterized by electrical measurements, while the chemical compositions and structures of coatings were analysed by X-ray photoelectron spectroscopy, Fourier-transform infrared spectroscopy, total combustion, and elastic recoil detection analyses, the latter two for determining carbon-to-hydrogen ratios. Scanning electron microscopy was used to study the coatings' morphology, and profilometry for evaluating deposition rates. - Highlights: • Atmospheric pressure DBD is used to deposit organic hydrocarbon films. • High deposition rates can be achieved by varying the power and/or gas mixture ratio. • Process parameters affect the films' surface chemical composition and morphology. • Deposited films are not soluble in aqueous environment. • No delamination of coatings produced from argon plasma.

  11. Patients with ovarian cancer have elevated (51)Cr-EDTA plasma clearance early post-operatively

    DEFF Research Database (Denmark)

    Nielsen, S S; Havsteen, H; Petersen, L K;

    2002-01-01

    Plasma clearance of (51)Cr-EDTA (Clp(EDTA)) is widely used to determine glomerular filtration rate prior to carboplatin based chemotherapy. We have observed that many patients with ovarian cancer have elevated Clp in the early post-operative phase compared to later phases. The purpose of this stu...

  12. The determination of the operation parameters at the axial hydraulic turbine

    Science.gov (United States)

    Simedru, A. I.

    2016-08-01

    In the operating point of the monitoring moment there are assumed from process the monitoring measured parameters: the active and reactive power, upstream and downstream water levels (after the intake trash rake and at the outlet of the turbine draft tube), wicket gate and runner opening blades, the differential pressure in the spiral chamber and the hydrounit speed. So, there was established the characteristic curves obtained on analytic basis and similitude and compared with the curves measured experimentally on the hydraulic machines from the power plant. The cavitational coefficient of the machine and the cavitational coefficient of the equipment are in function of the system parameters between them especially the suction head, the runner and wicket gates blades angles of opening. The solution proposed is a method of determining the operating turbine parameters and of the cavitation, by reducing the error caused by the similitude phenomenon, using an accurate estimation of the turbine operating parameters according to the universal diagram of the turbine. The numerical obtained values permit the necessary correlation through a complex function which is able to reduce or eliminate the unwished effects of the cavitation phenomena on the hydraulic turbines of the Iron Gates power plant.

  13. Correct manipulation method of MBR operating parameters in membrane fouling studies.

    Science.gov (United States)

    Kayaalp, N; Kinaci, C

    2013-01-01

    In this study, various parameter manipulation methods, variable sludge retention time (SRT)-variable mixed liquor suspended solids (MLSS) concentration, constant SRT-variable MLSS concentration and variable SRT-constant MLSS concentration, were compared based on the interrelationships among the following membrane bioreactor operating parameters: SRT, food to microorganisms (biomass) (F/M) ratio, MLSS concentration, volumetric organic loading rate (OLR) and membrane flux. Although it is the most applied method, concurrent change of SRT (or F/M ratio) and MLSS concentration is not a good parameter manipulation method because it causes unnecessary changes in many other parameters such as viscosity, oxygen transfer efficiency and oxygen utilization rate. The method of constant SRT-variable MLSS concentration has similar disadvantages to the method of variable SRT-variable MLSS concentration. The best alternative parameter manipulation method to study membrane fouling is the method of variable SRT-constant MLSS concentration because this method eliminates unnecessary changes in other parameters. In addition, while changing OLR or hydraulic retention time (HRT), contrary to the common application, membrane flux should be kept constant because any change in flux overrides changes in other parameters. Accordingly, required changes in OLR or HRT should be made by adjusting membrane area rather than membrane flux.

  14. Results of Current Density Distribution Mapping in PEM Fuel Cells Dependent on Operation Parameters

    Directory of Open Access Journals (Sweden)

    Zbigniew A. Styczynski

    2013-07-01

    Full Text Available This paper presents in situ measurements of a newly developed current density measurement system for proton exchange membrane fuel cells (PEMFC. While the functional principle and technical evaluation of the measurement system were presented in a previous paper, this paper analyzes the influence of various operation parameters, including multiple start-stop operation, at the anode, cathode and cooling locations on the distribution and long-term development of the current density. The system was operated for 500 h over two years with long periods of inactivity between measurements. The measurement results are evaluated and provide additional information on how to optimize the operation modes of fuel cells, including the start and stop of such systems as well as the water balance.

  15. Reducing PAH emissions from the iron ore sintering process by optimizing its operation parameters.

    Science.gov (United States)

    Chen, Yu-Cheng; Tsai, Perng-Jy; Mou, Jin-Luh

    2009-06-15

    This study set out to reduce polycyclic aromatic hydrocarbon (PAH) emissions from the iron ore sintering process by optimizing its operation parameters obtained from the Taguchi experimental design. Four operating parameters, including the water content (Wc; range = 6.0-7.0 wt %), suction pressure (Ps; range = 1000-1400 mmH2O), bed height (Hb; range = 500-600 mm), and type of hearth layer (HL; including sinter, hematite, and limonite) were selected and conducted on a pilot-scale sinter pot to simulate various sintering operating conditions of a real-scale sinter plant. We found that the resultant optimal combination (Wc = 6.5 wt %, Hb = 600 mm, Ps = 1400 mmH2O, and HL = limonite) could reduce the emission factor of total BaP equivalent concentration (EF(BaPeq)) up to 57.6% in comparison with the current operating condition of a real-scale sinter plant (Wc = 6.5 wt %, Hb = 550 mm, Ps = 1200 mmH2O, and HL = sinter). Through the ANOVA analysis, we found that Ps and Hb were the top two parameters affecting total EF(BaPeq) (accounting, respectively, for 70.9% and 21.2% of the total contribution of the four selected parameters). By examining both the sinter productivity and sinter strength, the values obtained from the optimal combination were quite comparable to those of the current operating condition. The above results further confirm the applicability of the obtained optimal combination for the real-scale sinter plant.

  16. Solar Cluster: multipoint magnetic field and plasma parameter measurements in the solar wind

    Science.gov (United States)

    Vieira, L. E.; Echer, E.; dal Lago, A.; Schuch, N. J.

    This paper has the objective to discus the technical-scientific feasibility of a deep space mission to be proposed to the Brazilian Space Agency (AEB). This mission will be proposed to study the interplanetary magnetic field and the plasma structure of the solar wind. It will consist of a set of identical spacecraft flying in formation in the inner heliosphere during the ascending and maximum phase of the solar cycle 24. It is know that the primary cause of magnetic storms are intense, long duration southward interplanetary magnetic field structures which interconnect with the earth's magnetic field and allow solar wind energy transport into the Earth's magnetotail/magnetosphere. During the most active phase of the solar cycle, solar maximum, the sun's activity is dominated by flares and disappearing filaments, and their concomitant Coronal Mass Ejections (CMEs). Coronal Holes are present, but the holes are small and do not extend from the poles to the equator as often happens in the descending phase of the solar cycle. The fast (>500 km/s) CMEs coming from the sun into the interplanetary space are the solar/coronal features that contain high magnetic fields. These intense southward magnetic fields are observed in the sheath, in the ejection itself and in the rear of the ejection. The interaction between CMEs and the background solar wind, fast co rotating streams and other CMEs are also very important sources of intense southward magnetic fields. In order to study the interplanetary origin of intense geomagnetic storms, several studies have analyzed plasma parameters, composition, ionization state and the interplanetary magnetic field measured by instruments on board of spacecraft as ISEE3, IMP8, Helios, Ulysses, Wind, SOHO and ACE. Great advance on the understanding of the CME structure and interaction with the background solar wind have been reached. However, the spatial scale of these structures could be greater than 0.2 AU, and this kind of observation usually

  17. Improving vacuum gas oil hydrotreating operation via a lumped parameter dynamic simulation modeling approach

    Energy Technology Data Exchange (ETDEWEB)

    Remesat, D.

    2008-07-01

    Although hydrotreating has become a large part of refining operations for sour crudes, refiners rarely achieve their run lengths and crude throughput objectives for vacuum gas oil (VGO) hydrotreaters. This shortfall in performance can be attributed to crude flow changes, feed compositional changes, sulphur and metals changes, or hydrogen partial pressure changes, all of which reduce the effectiveness of the catalysts that remove sulphur from the crude oil streams. Although some proprietary steady state models exist to indicate performance enhancement during operation, they have not been widely used and it is not certain whether they would be effective in simulating the process with disturbances over the run length of the process. This study used publicly unattainable data gathered from 14 operating hydrotreaters and developed a lumped parameter dynamic model, using both Excel and HYSYS software, for industrial refinery/upgrader VGO hydrotreaters. The model takes proprietary and public steady state hydrotreater models and successfully applies it to a commercial dynamic simulation package. The model tracks changes in intrinsic reaction rate based on catalyst deactivation, wetting efficiency, feed properties and operating conditions to determine operating temperature, outlet sulphur composition and chemical hydrogen consumed. The model simulates local disturbances, and represents the start, middle and end operating zones during hydrotreater run length. This correlative, partially predictive model demonstrates the economic benefits of increasing hydrogen to improve the operation of a hydrotreater by increasing run length and/or improving crude processing.

  18. Determination of rolling tyre modal parameters using Finite Element techniques and Operational Modal Analysis

    Science.gov (United States)

    Palanivelu, Sakthivel; Narasimha Rao, K. V.; Ramarathnam, Krishna Kumar

    2015-12-01

    In order to address various noise generation mechanisms and noise propagation phenomena of a tyre, it is necessary to study the tyre dynamic behaviour in terms of modal parameters. This paper enumerates a novel method of finding the modal parameters of a rolling tyre using an Explicit Finite Element Analysis and Operational Modal Analysis (OMA). ABAQUS Explicit, a commercial Finite Element (FE) software code has been used to simulate the experiment, a tyre rolling over a semi-circular straight and inclined cleat. The acceleration responses obtained from these simulations are used as input to the OMA. LMS test lab has been used for carrying out the Operational Modal Analysis. The modal results are compared with the published results of Kindt [22] and validated. Also, the modal results obtained from OMA are compared with FE modal results of stationary unloaded tyre, stationary loaded tyre and Steady State Transport rolling tyre.

  19. A novel membrane-based process to isolate peroxidase from horseradish roots: optimization of operating parameters.

    Science.gov (United States)

    Liu, Jianguo; Yang, Bo; Chen, Changzhen

    2013-02-01

    The optimization of operating parameters for the isolation of peroxidase from horseradish (Armoracia rusticana) roots with ultrafiltration (UF) technology was systemically studied. The effects of UF operating conditions on the transmission of proteins were quantified using the parameter scanning UF. These conditions included solution pH, ionic strength, stirring speed and permeate flux. Under optimized conditions, the purity of horseradish peroxidase (HRP) obtained was greater than 84 % after a two-stage UF process and the recovery of HRP from the feedstock was close to 90 %. The resulting peroxidase product was then analysed by isoelectric focusing, SDS-PAGE and circular dichroism, to confirm its isoelectric point, molecular weight and molecular secondary structure. The effects of calcium ion on HRP specific activities were also experimentally determined.

  20. Study of the operational properties of the Capillary Plasma Electrode (CPE) discharges

    Science.gov (United States)

    Lopez, Jose; Jacome, David; Zhu, Wei-Dong; Figus, Margaret; Becker, Kurt H.

    2009-03-01

    Various approaches have been pursued to create stable atmospheric pressure discharges by extending the lifetime of the diffuse phase of the discharge to hundreds of microseconds. Previous research showed that the stability of the diffuse mode is dependent on the frequency (in the kHz range), gas type power, mode of the excitation, and geometrical confinement. Some of the most promising approaches are based on the recognition of the arc formation in high-pressure plasmas can be avoided and stable high-pressure plasma can be generated and maintained when the plasma are spatially constricted to the dimensions of tens to hundreds of microns. The Capillary Plasma Electrode (CPE) discharge is stable to produce stable atmospheric pressure nonequilibrium plasma. The CPE is similar in design to the Barrier Electrode Discharge, but has perforated dielectrics. The configuration, aside from exhibiting a diffuse mode of operation, also exhibits the so-called ``capillary jet'' mode, in which the capillaries “turn on” and a bright plasma jet emerges from the capillaries. The capillary jets from adjacent capillaries overlap so that the discharge appears uniform when the electrode contains an array of holes. There appears to be a threshold frequency for the capillary jet formation, which is strongly dependent on the L/D ratio of the capillaries, where D is diameter of the capillary and L its length. However, the operating principles and basic properties of this behavior are not well understood. The current work explores these modes of operations of the CPE by characterizing the electrical and optical emission properties of this discharge by examining a multi-hole discharge as well as a single capillary discharge reactor.

  1. An Investigation of the dependence of CMS RPC operation on environmental parameters

    Energy Technology Data Exchange (ETDEWEB)

    Assran, Y. [Faculty of Petroleum and Mining Eng., Suez Canal University (Egypt); Colafranceschi, S. [INFN Laboratori Nazionali di Frascati, Via E. Fermi 40, I-00044 Frascati (Italy); Doninck, W.A. [Vrije Universiteit Brussel, B-1050 Brussels (Belgium); Sharma, A. [CERN, CH-1211, Geneva (Switzerland); Wickramage, N., E-mail: nwickram@cern.ch [EHEP, Tata Institute of Fundamental Research, Mumbai (India)

    2011-06-15

    In this paper an analysis is presented on performance of RPC chambers installed in the cosmic ray test stand at ISR, CERN. The currents of RPC chambers are studied as a function of environmental parameters such as temperature, humidity and pressure, which are important for the operation of the RPC detector system at CMS. A neural network approach has been used to analyze the data and to build a model using experimental measurements and combining the results of the simulations.

  2. Fresh-Frozen Plasma: Ordering Patterns and Utilization in the Operating Rooms of a Tertiary Referral Hospital.

    Science.gov (United States)

    Meyer, Matthew J; Dzik, Walter H; Levine, Wilton C

    2017-02-01

    Blood product transfusion is the most commonly performed hospital procedure. Intraoperative blood product utilization varies between institutions and anesthesiologists. In the United States in 2011, nearly 4 million plasma units were transfused. A retrospective analysis of intraoperative plasma ordering patterns and utilization (thawing and transfusing) was performed at a tertiary, academic hospital between January 2015 and March 2016. Over 15 months, 46,002 operative procedures were performed. In 1540 of them, plasma was thawed or transfused: 8297 plasma units were thawed and 3306 of those units were transfused. These 3306 plasma units were transfused in 749 cases with a median of 2 plasma units (interquartile range, 2-4) transfused. The percentage of average monthly procedures with plasma thawed and none transfused was 51.3% (confidence interval, 49.0%-53.6%). The cardiac surgery service requested the greatest number of plasma units to be thawed (2143) but only transfused 712 (33.2%) of them. Of all plasma units not transfused, 45% were generated by procedures with 1 to 4 units of plasma thawed; 95.7% of these units were thawed as even integers (ie, 2, 4). For operative procedures, far more plasma was thawed than was transfused and this practice occurred across surgical specialties and anesthesiologists. Considering the plasma that was not transfused, 45% occurred in procedures with 4 or fewer units of plasma requested suggesting these low-volume requests were a primary source of potential waste. Further studies are needed to examine associations between plasma utilization and clinical outcomes.

  3. Simulations of the operational control of a cryogenic plant for a superconducting burning-plasma tokamak

    CERN Document Server

    Mitchell, N

    2001-01-01

    In recent proposals for next generation superconducting tokamaks, such as the ITER project, the nuclear burning plasma is confined by magnetic fields generated from a large set (up to 100 GJ stored energy) of superconducting magnets. These magnets suffer heat loads in operation from thermal and nuclear radiation from the surrounding components and plasma as well as eddy currents and AC losses generated within the magnets, together with the heat conduction through supports and resistive heat generated at the current lead transitions to room temperature. The initial cryoplant for such a tokamak is expected to have a steady state capacity of up to about 85 kW at 4.5 K, comparable to the system installed for LHC at CERN. Experimental tokamaks are expected to operate at least initially in a pulsed mode with 20-30 short plasma pulses and plasma burn periods each day. A conventional cryoplant, consisting of a cold box and a set of primary heat exchangers, is ill-suited to such a mode of operation as the instantaneou...

  4. Impact investigation of reactor fuel operating parameters on reactivity for use in burnup credit applications

    Science.gov (United States)

    Sloma, Tanya Noel

    When representing the behavior of commercial spent nuclear fuel (SNF), credit is sought for the reduced reactivity associated with the net depletion of fissile isotopes and the creation of neutron-absorbing isotopes, a process that begins when a commercial nuclear reactor is first operated at power. Burnup credit accounts for the reduced reactivity potential of a fuel assembly and varies with the fuel burnup, cooling time, and the initial enrichment of fissile material in the fuel. With regard to long-term SNF disposal and transportation, tremendous benefits, such as increased capacity, flexibility of design and system operations, and reduced overall costs, provide an incentive to seek burnup credit for criticality safety evaluations. The Nuclear Regulatory Commission issued Interim Staff Guidance 8, Revision 2 in 2002, endorsing burnup credit of actinide composition changes only; credit due to actinides encompasses approximately 30% of exiting pressurized water reactor SNF inventory and could potentially be increased to 90% if fission product credit were accepted. However, one significant issue for utilizing full burnup credit, compensating for actinide and fission product composition changes, is establishing a set of depletion parameters that produce an adequately conservative representation of the fuel's isotopic inventory. Depletion parameters can have a significant effect on the isotopic inventory of the fuel, and thus the residual reactivity. This research seeks to quantify the reactivity impact on a system from dominant depletion parameters (i.e., fuel temperature, moderator density, burnable poison rod, burnable poison rod history, and soluble boron concentration). Bounding depletion parameters were developed by statistical evaluation of a database containing reactor operating histories. The database was generated from summary reports of commercial reactor criticality data. Through depletion calculations, utilizing the SCALE 6 code package, several light

  5. Effect of plasma parameters on characteristics of silicon nitride film deposited by single and dual frequency plasma enhanced chemical vapor deposition

    Science.gov (United States)

    Sahu, B. B.; Yin, Yongyi; Han, Jeon G.

    2016-03-01

    This work investigates the deposition of hydrogenated amorphous silicon nitride films using various low-temperature plasmas. Utilizing radio-frequency (RF, 13.56 MHz) and ultra-high frequency (UHF, 320 MHz) powers, different plasma enhanced chemical vapor deposition processes are conducted in the mixture of reactive N2/NH3/SiH4 gases. The processes are extensively characterized using different plasma diagnostic tools to study their plasma and radical generation capabilities. A typical transition of the electron energy distribution function from single- to bi-Maxwellian type is achieved by combining RF and ultra-high powers. Data analysis revealed that the RF/UHF dual frequency power enhances the plasma surface heating and produces hot electron population with relatively low electron temperature and high plasma density. Using various film analysis methods, we have investigated the role of plasma parameters on the compositional, structural, and optical properties of the deposited films to optimize the process conditions. The presented results show that the dual frequency power is effective for enhancing dissociation and ionization of neutrals, which in turn helps in enabling high deposition rate and improving film properties.

  6. Remote operation of the GOLEM tokamak with hydrogen and helium plasmas

    Science.gov (United States)

    Svoboda, V.; Dvornova, A.; Dejarnac, R.; Prochazka, M.; Zaprianov, S.; Akhmethanov, R.; Bogdanova, M.; Dimitrova, M.; Dimitrov, Zh; Grover, O.; Hlavata, L.; Ivanov, K.; Kruglov, K.; Marinova, P.; Masherov, P.; Mogulkin, A.; Mlynar, J.; Stockel, J.; Volynets, A.

    2016-10-01

    The GOLEM tokamak was operated remotely via Internet connection during the 6th International Workshop and Summer School on Plasma Physics. Performances of hydrogen and helium discharges are compared in this paper. It is found, at similar vacuum conditions, that helium discharges are shorter but the breakdown of the working gas can be quite easily achieved at almost the same loop voltage. The plasma current in helium discharges is slightly lower than in the case of hydrogen. Turbulent fluctuations of the floating potential measured by means of an array of Langmuir probes reveal a noticeably different character in the two discharges.

  7. New mode of operating a magnetized coaxial plasma gun for injecting magnetic helicity into a spheromak.

    Science.gov (United States)

    Woodruff, S; Hill, D N; Stallard, B W; Bulmer, R; Cohen, B; Holcomb, C T; Hooper, E B; McLean, H S; Moller, J; Wood, R D

    2003-03-07

    By operating a magnetized coaxial plasma gun continuously with just sufficient current to enable plasma ejection, large gun-voltage spikes (approximately 1 kV) are produced, giving the highest sustained voltage approximately 500 V and highest sustained helicity injection rate observed in the Sustained Spheromak Physics Experiment. The spheromak magnetic field increases monotonically with time, exhibiting the lowest fluctuation levels observed during formation of any spheromak (B/B>/=2%). The results suggest an important mechanism for field generation by helicity injection, namely, the merging of helicity-carrying filaments.

  8. Mathematical Modeling And Simulation of Photo-Voltaic Converter Operation when Varying Different Parameters

    Directory of Open Access Journals (Sweden)

    Miholca CONSTANTIN

    2008-07-01

    Full Text Available The paper presents a method of mathematical modelling of a solar converter using the results of full-scale testing. The advantages of analytical modelling method applied to photovoltaic systems are also presented; this is because the model parameters are directly measurable by data acquisition from the photovoltaic field consisting of photovoltaic cells type Z - (mono-crystalline photovoltaic. The model parameter also includes both the photovoltaic cell characteristics as a device (forming the photovoltaic field and the temperature influence on the photovoltaic field performance. The results of the photovoltaic model numerical simulation (PV to the major parameters conversion variation can also be used to design and assess the performance of low and medium - power photovoltaic systems operating in single regime (to supply the home appliances.

  9. A study of evolution/suppression parameters of equatorial postsunset plasma instability

    Directory of Open Access Journals (Sweden)

    O. S. Oyekola

    2009-01-01

    Full Text Available Evening equatorial pre-reversal vertical ion E×B drift (VZP and the peak of the ionospheric F2 maximum altitude (hmF2P of the postsunset equatorial F-layer, which are the essential parameters requisite for the generation or inhibition of postsunset bottomside equatorial irregularities were deduced from ionosonde observations made in the Africa region (Ouagadougou: ~3° N dip latitude between January 1987 and December 1990 for solar activity minimum, medium, and maxima (F10.7=85, 141, 214, and 190, respectively for quiet geomagnetic conditions. We investigate variations of evening equatorial pre-reversal drift and the corresponding altitude at four levels of solar activity. Our observations show strong variations with solar variability. Correlation analysis between these parameters indicates that the correlation coefficient value between hmF2P versus VZP decreases considerably with increasing solar flux value. There seems to be no significant link between these parameters under high solar activity, especially for solar intensity F10.7>200 units. We conclude that meridional neutral wind in the F-region contributes substantially to the variations of the pre-reversal vertical plasma drifts enhancement and the peak hmF2, particularly the electrodynamics during twilight high solar flux conditions.

  10. Potential Industrial Applications of the One Atmosphere Uniform Glow Discharge Plasma (OAUGDP) Operating in Ambient Air

    Science.gov (United States)

    Reece Roth, J.

    2004-11-01

    The majority of industrial plasma processing with glow discharges has been conducted at pressures below 10 torr. This tends to limit applications to high value workpieces as a result of the high capital cost of vacuum systems and the production constraints of batch processing. It has long been recognized that glow discharge plasmas would play a much larger industrial role if they could be generated at one atmosphere. The One Atmosphere Uniform Glow Discharge Plasma (OAUGDP), developed at the University of Tennessee's Plasma Sciences Laboratory, is a non-thermal RF plasma operating on displacement currents with the time-resolved characteristics of a classical low pressure DC normal glow discharge. As a glow discharge, the OAUGDP operates with maximum electrical efficiency at the Stoletow point, where the energy input per ion-electron pair is a minimum [1, 2]. Several interdisciplinary teams have investigated potential applications of the OAUGDP. These teams included collaborators from the UTK Textiles and Nonwovens Development Center (TANDEC), and the Departments of Electrical and Computer Engineering, Microbiology, and Food Science and Technology, as well as the NASA Langley Research Center. The potential applications of the OAUGDP have all been at one atmosphere and room temperature, using air as the working gas. These applications include sterilizing medical and dental equipment; sterilizable air filters to deal with the "sick building syndrome"; removal of soot from Diesel engine exhaust; subsonic plasma aerodynamic effects, including flow re-attachment to airfoils and boundary layer modification; electrohydrodynamic (EDH) flow control of working gases; increasing the surface energy of materials; improving the adhesion of paints and electroplated layers: improving the wettability and wickability of fabrics; stripping of photoresist; and plasma deposition and directional etching of potential microelectronic relevance. [1] J. R. Roth, Industrial Plasma Engineering

  11. Determination of Initial Conditions for the Safety Analysis by Random Sampling of Operating Parameters

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Hae-Yong; Park, Moon-Ghu [Sejong University, Seoul (Korea, Republic of)

    2015-05-15

    In most existing evaluation methodologies, which follow a conservative approach, the most conservative initial conditions are searched for each transient scenario through tremendous assessment for wide operating windows or limiting conditions for operation (LCO) allowed by the operating guidelines. In this procedure, a user effect could be involved and a remarkable time and human resources are consumed. In the present study, we investigated a more effective statistical method for the selection of the most conservative initial condition by the use of random sampling of operating parameters affecting the initial conditions. A method for the determination of initial conditions based on random sampling of plant design parameters is proposed. This method is expected to be applied for the selection of the most conservative initial plant conditions in the safety analysis using a conservative evaluation methodology. In the method, it is suggested that the initial conditions of reactor coolant flow rate, pressurizer level, pressurizer pressure, and SG level are adjusted by controlling the pump rated flow, setpoints of PLCS, PPCS, and FWCS, respectively. The proposed technique is expected to contribute to eliminate the human factors introduced in the conventional safety analysis procedure and also to reduce the human resources invested in the safety evaluation of nuclear power plants.

  12. Calculation of Reactor Kinetics Parameters βeff and Λ with Monte Carlo Differential Operator Sampling

    Science.gov (United States)

    Nagaya, Yasunobu

    2014-06-01

    The methods to calculate the kinetics parameters of βeff and Λ with the differential operator sampling have been reviewed. The comparison of the results obtained with the differential operator sampling and iterated fission probability approaches has been performed. It is shown that the differential operator sampling approach gives the same results as the iterated fission probability approach within the statistical uncertainty. In addition, the prediction accuracy of the evaluated nuclear data library JENDL-4.0 for the measured βeff/Λ and βeff values is also examined. It is shown that JENDL-4.0 gives a good prediction except for the uranium-233 systems. The present results imply the need for revisiting the uranium-233 nuclear data evaluation and performing the detailed sensitivity analysis.

  13. Behavior of Plasma and Field Parameters and their Relationship with Geomagnetic Indices during Intense Geomagnetic Storms of Solar Cycle 23

    CERN Document Server

    Joshi, Navin Chandra; Pande, Seema; Pande, Bimal; Pandey, Kavita

    2010-01-01

    A correlative study between the geomagnetic indices and the peak values of various plasma and field parameters during rising, maximum and decay phases as well as during complete solar cycle 23 have been presented. We have also presented the lag/lead analysis between the maximum of Dst and peak values of plasma and field parameters and found that peak values of lag/lead time lies in the +/-10 hr interval. Three geomagnetic storms (GMSs) and associated solar sources observed during these phases of this solar cycle have also been studied and found that GMSs are associated with large flares and halo CMEs.

  14. Levels of oxidative stress biomarkers in seminal plasma and their relationship with seminal parameters

    Directory of Open Access Journals (Sweden)

    Zarghami Nosratollah

    2007-06-01

    Full Text Available Abstract Background There is growing evidence that damage to spermatozoa by reactive oxygen species (ROS play a key role in male infertility. The aim of the present study was to assess seminal plasma levels of total antioxidant capacity (TAC, free 8-Isoprostane and activities of catalase and superoxide dismutase (SOD in men with asthenozoospermia, asthenoteratozoospermia and oligoasthenoteratozoospermia compared with normozoospermic males. Methods The patients consisted of 46 men with seminal parameters abnormalities. The patients were grouped into asthenozoospermic (n = 15, asthenoteratozoospermic (n = 16 and oligoasthenoteratozoospermic (n = 15. The control group consisted of 16 healthy males with normozoospermia. Catalase activity was measured by Aebi spectrophotometeric method. Levels of TAC and SOD were measured by commercially available colorimetric assays. Level of free 8-Isoprostane was assessed by commercially available enzyme immunoassay (EIA method. Differences between groups were assessed using Mann-Whitney U test and Kruskal-Wallis test. Coefficients of correlation were calculated using Spearman's correlation analysis. All hypothesis tests were two-tailed with statistical significance assessed at the p value Results Levels of catalase and TAC were significantly lower in patients than the control group. No significant changes were seen in SOD activities. Levels of free 8-Isoprostane were significantly higher in patients than the control group. Furthermore, asthenozoospermic, asthenoteratozoospermic and oligoasthenoteratozoospermic groups had significantly lower values of catalase activity and TAC when compared to normozoospermic males. Levels of free 8-Isoprostane were significantly higher in all patients subgroups than the control group. Levels of catalase and TAC were positively correlated with sperm motility and morphology. Free 8-Isoprostane levels showed an inverse correlation with sperm motility and morphology. Conclusion

  15. Subclinical hypocalcemia, plasma biochemical parameters, lipid metabolism, postpartum disease, and fertility in postparturient dairy cows.

    Science.gov (United States)

    Chamberlin, W G; Middleton, J R; Spain, J N; Johnson, G C; Ellersieck, M R; Pithua, P

    2013-01-01

    A study was conducted to evaluate the potential association between Ca status at calving and postpartum energy balance, liver lipid infiltration, disease occurrence, milk yield and quality parameters, and fertility in Holstein cows. One hundred cows were assigned to 1 of 2 groups based on whole-blood ionized Ca concentration ([iCa]) on the day of calving [d 0; hypocalcemic [iCa] Cows were blocked based on calving date and parity. Blood samples were collected approximately 14 d from expected calving date (d -14), the day of calving (d 0), and on d 3, 7, 14, 21, and 35 postpartum for measurement of plasma nonesterified fatty acid, iCa, total Ca, glucose, and total and direct bilirubin concentrations, and plasma aspartate aminotransferase and gamma glutamyl transferase activities. Liver biopsies were obtained from a subset of cows on d 0, 7, and 35 for quantification of lipid content. Milk samples were collected on d 3, 7, 14, 21, and 35 postpartum for measurement of somatic cell count and percentages of protein, fat, and solids-not-fat. Data for peak test-day milk yield, services per conception, and days open were obtained from Dairy Herd Improvement Association herd records. Disease occurrence was determined based on herd treatment records. Hypocalcemic cows had significantly higher nonesterified fatty acids on d 0. Hypocalcemic cows also had significantly more lipid in hepatocytes on d 7 and 35 postpartum. However, no statistically significant differences were observed between groups for plasma aspartate aminotransferase and gamma glutamyl transferase activities or total and direct bilirubin concentrations. Milk protein percentage was lower in hypocalcemic cows on d 21 and 35. However other milk quality variables (somatic cell count, milk fat percentage, and solids-not-fat) and milk yield variables (peak test-day milk yield and 305-d mature-equivalent 4% fat-corrected milk yield) did not differ between groups. No differences were observed between groups in the

  16. In vivo triglyceride synthesis in subcutaneous adipose tissue of humans correlates with plasma HDL parameters

    Science.gov (United States)

    Tuvdendorj, Demidmaa; Munoz, Alejandro O.; Ruiz-Barros, Viviana; Schwarz, Jean-Marc; Montalto, Giuseppe; Chandalia, Manisha; Sowers, Lawrence C.; Rizzo, Manfredi; Murphy, Elizabeth J; Abate, Nicola

    2016-01-01

    Backgrounds and aims Low concentrations of plasma HDL-C are associated with the development of atherosclerotic cardiovascular diseases and type 2 diabetes. Here we aimed to explore the relationship between the in vivo fractional synthesis of triglycerides (fTG) in subcutaneous (s.q.) abdominal adipose tissue (AT), HDL-C concentrations and HDL particle size composition in non-diabetic humans. Methods The fTG in s.q. abdominal AT was measured in 16 non-diabetic volunteers (7 women, 9 men; Age: 49±20 years; BMI: 31±5 kg/m; Fasting Plasma Glucose: 90±10 mg/dl) after 2H2O labeling. HDL-C concentration and subclasses, large (L-HDL), intermediate (I-HDL) and small (S-HDL) were measured. Results Linear regression analyses demonstrated significant associations of fTG with plasma concentration of HDL-C (r=0.625,p=0.009) and percent contribution of L-HDL (r=0.798,pHDL (r=−0.765,pHDL (r=−0.629, p=0.009). When analyses were performed by gender, the associations remained significant in women (HDL-C: r=0.822,p=0.023; L-HDL: r=0.892,p=0.007; I-HDL: r=−0.927,p=0.003) but not men. Conclusions Our study demonstrated an in vivo association between subcutaneous abdominal adipose tissue lipid dynamics and HDL parameters in humans, but this was true for women not men. Positive association with L-HDL and negative with I-HDL suggest that subcutaneous abdominal adipose tissue lipid dynamics may play an important role in production of mature functional HDL particles. Further studies evaluating the mechanism responsible for these associations and the observed gender differences are important and warranted to identify potential novel targets of intervention to increase the production of atheroprotective subclasses of HDL-Cs and thus decreasing the risks of development of atherosclerotic conditions. PMID:27323227

  17. The role of spatial confinement for improvement of laser-induced Mg plasma parameters and growth of surface features

    Science.gov (United States)

    Hayat, Asma; Bashir, Shazia; Rafique, Muhammad Shahid; Ahmad, Riaz; Akram, Mahreen; Mahmood, Khaliq; Zaheer, Ali

    2017-08-01

    The role of spatial confinement for improvement of laser-induced Mg plasma parameters and growth of surface features is investigated by introducing a metallic blocker. Nd: YAG laser at various fluences ranging from 7 to 28 J cm-2 was employed as an irradiation source. All measurements were performed in the presence of Ar under different pressures. Confinement effects offered by metallic blocker are investigated by placing the blocker at different distances of 6, 8 and 10 mm from the target surface. It is revealed from laser-induced breakdown spectroscopy analysis that both plasma parameters, i.e., excitation temperature and electron number density initially increase with increasing laser fluence due to enhancement in energy deposition. With further increase in laser fluence, a decreasing trend followed by saturation is observed which is attributable to shielding effect and self-regulating regime. It is also observed that spatial confinement offered by metallic blocker is responsible for the significant enhancement of both electron temperature and electron number density of Mg plasma. This is true for all laser fluences and pressures of Ar. Maximum values of electron temperature and electron number density without blocker are 8335 K and 2.4 × 1016 cm-3, respectively, whereas these values are enhanced to 12,200 K and 4 × 1016 cm-3 in the presence of the blocker. The physical mechanisms responsible for the enhancement of Mg plasma parameters are plasma compression, confinement and pronounced collisional excitations due to reflection of shock waves. Scanning electron microscope analysis was performed to explore the surface morphology of laser-ablated Mg. It reveals the formation of cones, cavities and ripples. These features become more distinct and well defined in the presence of the blocker due to plasma confinement. The optimum combination of blocker distance, fluence and Ar pressure can identify the suitable conditions for defining the role of plasma parameters

  18. Ignition Features of Plasma-Beam Discharge in Gas-Discharge Electron Gun Operation

    Directory of Open Access Journals (Sweden)

    Valery A. Tutyk

    2013-01-01

    Full Text Available The current paper presents the results of experimental researches to determine the mode features of plasma-beam discharge (PBD generation by an electron beam injected by a low-vacuum gasdischarge electron gun (LGEG with the cold cathode and hollow anode on the basis of the high-voltage glow discharge and in the range of helium pressure of P ? 10 ÷ 130 Pa. The PBD boundaries and their dependences on parameters of an electron beam are found. The influence of PBD on parameters of low-vacuum gas-discharge electron gun is revealed. It causes an avalanche increase of electron beam current and burning of plasma-beam discharge in the whole space of the vacuum chamber volume and generation of electromagnetic radiation is revealed. Achieved results will be used for implementation of various vacuum technologies in the medium of reaction gas and generated electromagnetic radiation.

  19. Influence of the initial parameters of the magnetic field and plasma on the spatial structure of the electric current and electron density in current sheets formed in helium

    Energy Technology Data Exchange (ETDEWEB)

    Ostrovskaya, G. V., E-mail: galya-ostr@mail.ru [Russian Academy of Sciences, Ioffe Physical Technical Institute (Russian Federation); Markov, V. S.; Frank, A. G., E-mail: annfrank@fpl.gpi.ru [Russian Academy of Sciences, Prokhorov General Physics Institute (Russian Federation)

    2016-01-15

    The influence of the initial parameters of the magnetic field and plasma on the spatial structure of the electric current and electron density in current sheets formed in helium plasma in 2D and 3D magnetic configurations with X-type singular lines is studied by the methods of holographic interferometry and magnetic measurements. Significant differences in the structures of plasma and current sheets formed at close parameters of the initial plasma and similar configurations of the initial magnetic fields are revealed.

  20. An alternative factorization of the quantum harmonic oscillator and two-parameter family of self-adjoint operators

    Energy Technology Data Exchange (ETDEWEB)

    Arcos-Olalla, Rafael, E-mail: olalla@fisica.ugto.mx [Departamento de Física, DCI Campus León, Universidad de Guanajuato, Apdo. Postal E143, 37150 León, Gto. (Mexico); Reyes, Marco A., E-mail: marco@fisica.ugto.mx [Departamento de Física, DCI Campus León, Universidad de Guanajuato, Apdo. Postal E143, 37150 León, Gto. (Mexico); Rosu, Haret C., E-mail: hcr@ipicyt.edu.mx [IPICYT, Instituto Potosino de Investigacion Cientifica y Tecnologica, Apdo. Postal 3-74 Tangamanga, 78231 San Luis Potosí, S.L.P. (Mexico)

    2012-10-01

    We introduce an alternative factorization of the Hamiltonian of the quantum harmonic oscillator which leads to a two-parameter self-adjoint operator from which the standard harmonic oscillator, the one-parameter oscillators introduced by Mielnik, and the Hermite operator are obtained in certain limits of the parameters. In addition, a single Bernoulli-type parameter factorization, which is different from the one introduced by M.A. Reyes, H.C. Rosu, and M.R. Gutiérrez [Phys. Lett. A 375 (2011) 2145], is briefly discussed in the final part of this work. -- Highlights: ► Factorizations with operators which are not mutually adjoint are presented. ► New two-parameter and one-parameter self-adjoint oscillator operators are introduced. ► Their eigenfunctions are two- and one-parameter deformed Hermite functions.

  1. Operational Characteristics and Plasma Measurements in a Low-Energy FARAD Thruster

    Science.gov (United States)

    Polzin, K. A.; Best, S.; Rose, M. F.; Miller, R.; Owens, T.

    2008-01-01

    Pulsed inductive plasma accelerators are spacecraft propulsion devices in which energy is stored in a capacitor and then discharged through an inductive coil. The device is electrodeless, inducing a plasma current sheet in propellant located near the face of the coil. The propellant is accelerated and expelled at a high exhaust velocity (order of 10 km/s) through the interaction of the plasma current with an induced magnetic field. The Faraday Accelerator with RF-Assisted Discharge (FARAD) thruster is a type of pulsed inductive plasma accelerator in which the plasma is preionized by a mechanism separate from that used to form the current sheet and accelerate the gas. Employing a separate preionization mechanism in this manner allows for the formation of an inductive current sheet at much lower discharge energies and voltages than those found in previous pulsed inductive accelerators like the Pulsed Inductive Thruster (PIT). In this paper, we present measurements aimed at quantifying the thruster's overall operational characteristics and providing additional insight into the nature of operation. Measurements of the terminal current and voltage characteristics during the pulse help quantify the output of the pulsed power train driving the acceleration coil. A fast ionization gauge is used to measure the evolution of the neutral gas distribution in the accelerator prior to a pulse. The preionization process is diagnosed by monitoring light emission from the gas using a photodiode, and a time-resolved global view of the evolving, accelerating current sheet is obtained using a fast-framing camera. Local plasma and field measurements are obtained using an array of intrusive probes. The local induced magnetic field and azimuthal current density are measured using B-dot probes and mini-Rogowski coils, respectively. Direct probing of the number density and electron temperature is performed using a triple probe.

  2. Optimizing stability, transport, and divertor operation through plasma shaping for steady-state scenario development in DIII-Da)

    Science.gov (United States)

    Holcomb, C. T.; Ferron, J. R.; Luce, T. C.; Petrie, T. W.; Politzer, P. A.; Challis, C.; DeBoo, J. C.; Doyle, E. J.; Greenfield, C. M.; Groebner, R. J.; Groth, M.; Hyatt, A. W.; Jackson, G. L.; Kessel, C.; La Haye, R. J.; Makowski, M. A.; McKee, G. R.; Murakami, M.; Osborne, T. H.; Park, J.-M.; Prater, R.; Porter, G. D.; Reimerdes, H.; Rhodes, T. L.; Shafer, M. W.; Snyder, P. B.; Turnbull, A. D.; West, W. P.

    2009-05-01

    Recent studies on the DIII-D tokamak [J. L. Luxon, Nucl. Fusion 42, 614 (2002)] have elucidated key aspects of the dependence of stability, confinement, and density control on the plasma magnetic configuration, leading to the demonstration of nearly noninductive operation for >1 s with pressure 30% above the ideal no-wall stability limit. Achieving fully noninductive tokamak operation requires high pressure, good confinement, and density control through divertor pumping. Plasma geometry affects all of these. Ideal magnetohydrodynamics modeling of external kink stability suggests that it may be optimized by adjusting the shape parameter known as squareness (ζ). Optimizing kink stability leads to an increase in the maximum stable pressure. Experiments confirm that stability varies strongly with ζ, in agreement with the modeling. Optimization of kink stability via ζ is concurrent with an increase in the H-mode edge pressure pedestal stability. Global energy confinement is optimized at the lowest ζ tested, with increased pedestal pressure and lower core transport. Adjusting the magnetic divertor balance about a double-null configuration optimizes density control for improved noninductive auxiliary current drive. The best density control is obtained with a slight imbalance toward the divertor opposite the ion grad(B) drift direction, consistent with modeling of these effects. These optimizations have been combined to achieve noninductive current fractions near unity for over 1 s with normalized pressure of 3.565%, and a normalized confinement factor of H98(y ,2)≈1.5.

  3. Effect of basic physical parameters to control plasma meniscus and beam halo formation in negative ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Miyamoto, K. [Naruto University of Education, 748 Nakashima, Takashima, Naruto-cho, Naruto-shi, Tokushima 772-8502 (Japan); Okuda, S.; Nishioka, S.; Hatayama, A. [Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522 (Japan)

    2013-09-14

    Our previous study shows that the curvature of the plasma meniscus causes the beam halo in the negative ion sources: the negative ions extracted from the periphery of the meniscus are over-focused in the extractor due to the electrostatic lens effect, and consequently become the beam halo. In this article, the detail physics of the plasma meniscus and beam halo formation is investigated with two-dimensional particle-in-cell simulation. It is shown that the basic physical parameters such as the H{sup −} extraction voltage and the effective electron confinement time significantly affect the formation of the plasma meniscus and the resultant beam halo since the penetration of electric field for negative ion extraction depends on these physical parameters. Especially, the electron confinement time depends on the characteristic time of electron escape along the magnetic field as well as the characteristic time of electron diffusion across the magnetic field. The plasma meniscus penetrates deeply into the source plasma region when the effective electron confinement time is short. In this case, the curvature of the plasma meniscus becomes large, and consequently the fraction of the beam halo increases.

  4. Operating Regime for a Backward Raman Laser Amplifier in Preformed Plasma

    Energy Technology Data Exchange (ETDEWEB)

    Daniel S. Clark; Nathaniel J. Fisch

    2003-02-06

    A critical issue in the generation of ultra-intense, ultra-short laser pulses by backward Raman scattering in plasma is the stability of the pumping pulse to premature backscatter from thermal fluctuations in the preformed plasma. Malkin et al. [V.M. Malkin, et al., Phys. Rev. Lett. 84 (6):1208-1211, 2000] demonstrated that density gradients may be used to detune the Raman resonance in such a way that backscatter of the pump from thermal noise can be stabilized while useful Raman amplification persists. Here plasma conditions for which the pump is stable to thermal Raman backscatter in a homogeneous plasma and the density gradients necessary to stabilize the pump for other plasma conditions are quantified. Other ancillary constraints on a Raman amplifier are also considered to determine a specific region in the Te-he plane where Raman amplification is feasible. By determining an operability region, the degree of uncertainty in density or temperature tolerable for an experimental Raman amplifier is thus also identified. The fluid code F3D, which includes the effects of thermal fluctuations, is used to verify these analytic estimates.

  5. Emission spectroscopy of an atmospheric pressure plasma jet operated with air at low frequency

    Science.gov (United States)

    Giuliani, L.; Gallego, J. L.; Minotti, F.; Kelly, H.; Grondona, D.

    2015-03-01

    Low-temperature, high-pressure plasma jets have an extensive use in plasma biology and plasma medicine, such as pathogen deactivation, wound disinfection, stopping of bleeding without damage of healthy tissue, acceleration of wound healing, control of bio-film proliferation, etc. In this work, a spectroscopic characterization of a typical plasma jet, operated in air at atmospheric pressure, is reported. Within the spectrum of wavelengths from 200 to 450 nm all remarkable emissions of N2 were monitored. Spectra of the N2 2nd positive system (C3Πu-B3Πg) emitted in air are the most convenient for plasma diagnostics, since they enable to determine electronic Te, rotational Tr and vibrational Tv temperatures by fitting the experimental spectra with the simulated ones. We used SPECAIR software for spectral simulation and obtained the best fit with all these temperatures about 3500K. The conclusion that all temperatures are equal, and its relatively high value, is consistent with the results of a previous work, where it was found that the experimentally determined electrical characteristic was consistent with the model of a thermal arc discharge, together with a highly collisional cathode sheet.

  6. Design and operation of the RFX-mod plasma shape control system

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, G., E-mail: giuseppe.marchiori@igi.cnr.it [Consorzio RFX, Corso Stati Uniti 4, 35127 Padova (Italy); Finotti, C. [Consorzio RFX, Corso Stati Uniti 4, 35127 Padova (Italy); Kudlacek, O. [Università di Padova, Padova (Italy); Villone, F. [Dipartimento di Ingegneria Elettrica e dell’Informazione (DIEI), Università di Cassino (Italy); Zanca, P. [Consorzio RFX, Corso Stati Uniti 4, 35127 Padova (Italy); Abate, D. [Dipartimento di Ingegneria Elettrica e dell’Informazione (DIEI), Università di Cassino (Italy); Cavazzana, R. [Consorzio RFX, Corso Stati Uniti 4, 35127 Padova (Italy); Jackson, G.L.; Luce, T.C. [General Atomics, San Diego, CA (United States); Marrelli, L. [Consorzio RFX, Corso Stati Uniti 4, 35127 Padova (Italy)

    2016-10-15

    Highlights: • Linearized plasma response model of RFX-mod Tokamak Double/Single Null discharges. • Model based design of a vertical stability control system. • Model based design of a plasma shape LQG control system with Kalman state estimator. • Real time plasma boundary reconstruction algorithm. • Tracking and disturbance rejection experimental tests. - Abstract: The aim of executing Single Null discharges in RFX-mod operating as a Tokamak led to the design and implementation of a plasma shape feedback control system. A fully model-based approach was followed which allowed dealing with critical issues such as the presence of a conducting shell, the strong coupling of the poloidal field coils and the voltage limits of the power supplies. A Linear Quadratic regulator and a Kalman state estimator were designed and implemented in the real time MARTe framework together with an algorithm for the real-time plasma boundary reconstruction. The problem of a number of sensors along the poloidal direction adequate only for circular discharges was also successfully tackled. The development of the system and its performances in terms of tracking and disturbance rejection capability are presented in the paper.

  7. Anaerobic monodigestion of poultry manure: determination of operational parameters for CSTR.

    Science.gov (United States)

    Chamy, R; León, C; Vivanco, E; Poirrier, P; Ramos, C

    2012-01-01

    In this work the anaerobic monodigestion for the treatment of turkey manure was evaluated, without its codigestion with another substrate. The effect of the organic loading rate (OLR) and the substrate concentration (high total solids (TS) concentration) or product concentration (high volatile fatty acids (VFA) and/or ammonia (NH(3)-N) concentrations) was studied. The results show that for a continuous stirred tank reactor (CSTR) operation, a maximum of 40 g/L of TS and 4.0 g/L of ammonium (NH(4)(+)) was required. In addition, the maximum organic loading rate (OLR) will not exceed 1.5 kg VS/m(3)d. Higher TS and NH(4)(+) concentrations and OLR lead to a reduction on the methane productivity and volatile solids (VS) removal. During the CSTR operation, a high alkalinity concentration (above 10 g/L CaCO(3)) was found; this situation allowed maintaining a constant and appropriate pH (close to 7.8), despite the VFA accumulation. In this sense, the alkalinity ratio (α) is a more appropriate control and monitoring parameter of the reactor operation compared to pH. Additionally, with this parameter a VS removal of 80% with a methane productivity of 0.50 m(3)(CH4)/m(3)(R)d is achieved.

  8. Optimization of operating parameters of internally cooled superconducting cables; Optimale Betriebsparameter fuer intern gekuehlte Supraleiterkabel

    Energy Technology Data Exchange (ETDEWEB)

    Katheder, H. [Max-Planck-Inst. fuer Plasmaphysik, Garching (Germany). NET Team

    1995-12-31

    Large superconducting coils such as are used for fusion experiments (Tokamak or Stellarator confiurations) are best equipped with internally cooled superconducting cables. These cables, which are cooled with helium at 4 Koperating parameters inlet temperature, pressure drop, mass flow, and inlet pressure. These operating parameters are optimally adjusted when the cable can be cooled with minimum mass flow. The present paper deals with the thermodynamic behaviour of flowing helium in conduits and with the thermal load which may occur in a cable. It describes a mehtod of optimising the operating paramters and gives a numerical calculation using typical cable data. (orig.) [Deutsch] Bei grossen supraleitenden Spulen z.B. fuer Fusionsexperimente (Tokamak- oder Stellarator Anordnungen) werden mit Vorteil intern gekuehlte Supraleiterkabel eingesetzt. Seit einigen Jahren werden solche Kabel, gekuehlt mit Helium bei 4

  9. Multicriteria Optimization of Gasification Operational Parameters Using a Pareto Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    Miguel Caldas

    2005-04-01

    Full Text Available Gasification is a well-known technology that allows for a combustible gas to be obtained from a carbonaceous fuel by a partial oxidation process (POX. The resulting gas (synthesis gas or syngas can be used either as a fuel or as a feedstock for chemical production. Recently, gasification has also received a great deal of attention concerning power production possibilities through IGCC process (Integrated Gasification Combined Cycle, which is currently the most environmentally friendly and efficient method for the production of electricity. Gasification allows for low grade fuels, or dirty fuels, to be used in an environmental acceptable way. Amongst these fuels are wastes from the petrochemical and other industries, which vary in composition from shipment to shipment, and from lot to lot. If operating conditions are kept constant this could result in lose of efficiency. This paper presents an application of Genetic Algorithms to optimize the operating parameters of a gasifier processing a given fuel, so that the system achieves maximum efficiency for each particular fuel composition. A Pareto multiobjective optimization method, combined with a Genetic Algorithm, is applied to the simultaneous maximization of two different objective functions: Cold Gas Efficiency and Hydrogen Contents of the syngas. Results show that the optimization method developed is fast and simple enough to be used for on-line adjustment of the gasification operating parameters for each fuel composition and aim of gasification, thus improving overall performance of the industrial process.

  10. Operational Status of the International Space Station Plasma Contactor Hollow Cathode Assemblies July 2001 to May 2013

    Science.gov (United States)

    Kamhawi, Hani; Yim, John T.; Patterson, Michael J.; Dalton, Penni J.

    2013-01-01

    The International Space Station has onboard two Aerojet Rocketdyne developed plasma contactor units that perform the function of charge control. The plasma contactor units contain NASA Glenn Research Center developed hollow cathode assemblies. NASA Glenn Research Center monitors the on-orbit operation of the flight hollow cathode assemblies. As of May 31, 2013, HCA.001-F has been ignited and operated 123 times and has accumulated 8072 hours of operation, whereas, HCA.003-F has been ignited and operated 112 times and has accumulated 9664 hours of operation. Monitored hollow cathode ignition times and anode voltage magnitudes indicate that they continue to operate nominally.

  11. Operational Status of the International Space Station Plasma Contactor Hollow Cathode Assemblies from July 2011 to May 2013

    Science.gov (United States)

    Kamhawi, Hani; Yim, John T.; Patterson, Michael J.; Dalton, Penni J.

    2014-01-01

    The International Space Station has onboard two Aerojet Rocketdyne developed plasma contactor units that perform the function of charge control. The plasma contactor units contain NASA Glenn Research Center developed hollow cathode assemblies. NASA Glenn Research Center monitors the onorbit operation of the flight hollow cathode assemblies. As of May 31, 2013, HCA.001-F has been ignited and operated 123 times and has accumulated 8072 hours of operation, whereas, HCA.003-F has been ignited and operated 112 times and has accumulated 9664 hours of operation. Monitored hollow cathode ignition times and anode voltage magnitudes indicate that they continue to operate nominally.

  12. Experimental measurements of the hollow cathode DC glow discharge parameters in Ar and He plasmas

    Science.gov (United States)

    Omrani, M.; Amrollahi, R.; Iraji, D.

    2016-12-01

    In this article, we focus on some of the fundamental parameters of SS316L hollow cathode glow discharge. Four SS316L samples are placed at different locations on the cathode surface and the current passed through them is measured in Ar and He glow discharge plasmas. The wall current densities of Ar and He are in the range of 8-25 µA cm-2 and 8-35 µA cm-2, respectively. Results also show that with decreasing working pressure, the ion flux and current density distribution on the wall surface becomes more uniform. The ion flux of the Ar and He is in the range of 1013 to 1014 ~\\text{ion} \\text{c}{{\\text{m}}-2} . Total energy losses of Ar and He are measured at the pressure range of 1.4-5.5  ×  10-2 torr and 3.2-7.1  ×  10-1, respectively. In both Ar and He, total energy losses decreased with increasing pressure. The secondary electron emission coefficients of Ar and He, which are evaluated for the hallow cathode configuration, are about 0.42 and 0.26, respectively, and are higher in comparison with the plate cathode configuration.

  13. Effect of dietary protein sources on production performance, egg quality, and plasma parameters of laying hens

    Science.gov (United States)

    Wang, Xiaocui; Zhang, Haijun; Wang, Hao; Wang, Jing; Wu, Shugeng; Qi, Guanghai

    2017-01-01

    Objective This study was conducted to evaluate the effects of dietary protein sources (soybean meal, SBM; low-gossypol cottonseed meal, LCSM; double-zero rapeseed meal, DRM) on laying performance, egg quality, and plasma parameters of laying hens. Methods A total of 432 32-wk-old laying hens were randomly divided into 6 treatments with 6 replicates of 12 birds each. The birds were fed diets containing SBM, LCSM100, or DRM100 individually or in combination with an equal amount of crude protein (CP) (LCSM50, DRM50, and LCSM50-DRM50). The experimental diets, which were isocaloric (metabolizable energy, 11.11 MJ/kg) and isonitrogenous (CP, 16.5%), had similar digestible amino acid profile. The feeding trial lasted 12 weeks. Results The daily egg mass was decreased in the LCSM100 and LCSM50-DRM50 groups (p0.05) and showed increased yolk color at the end of the trial (p0.05). Conclusion Together, our results suggest that the LCSM100 or DRM100 diets may produce the adverse effects on laying performance and egg quality after feeding for 8 more weeks. The 100.0 g/kg LCSM diet or the148.7 g/kg DRM diet has no adverse effects on laying performance and egg quality. PMID:27608634

  14. Parameter Study of Plasma-Induced Atmospheric Sputtering and Heating at Mars

    Science.gov (United States)

    Williamson, Hayley N.; Johnson, Robert E.; Leblanc, Francois

    2014-11-01

    Atoms and molecules in Mars’ upper atmosphere are lost predominately through sputtering, caused by the impact of ions into the exosphere, dissociative recombination, and thermal escape. While all three processes are thought to occur on Mars, a detailed understanding must ascertain the relative importance of each process, due to time variations in pick-up and solar wind ions. In this project, using case studies of an oxygen atmosphere modeled with Direct Simulation Monte Carlo techniques, we have endeavored to categorize when the momentum transfer or thermal escape is more likely to occur. To do this, we vary the incident plasma flux and energy based on models of the interaction of the solar wind with the Martian atmosphere. We first repeat the heating and sputtering rates due to a flux of pick-up O+ examined previously (Johnson et al. 2000; Michael and Johnson 2005; Johnson et al 2013). We have used multiple examples of particle fluxes for various solar wind conditions, from steady solar wind conditions (Luhmann et al. 1992; Chaufray et al. 2007) to more extreme cases (Fang et al. 2013; Wang et al. 2014), which are thought to increase escape by several orders of magnitude. The goal is to explore the escape parameter space in preparation for the expected data from MAVEN on hot atoms and molecules in the Martian exosphere.

  15. Plasma parameters in the vicinity of the quartz window of a low pressure surface wave discharge produced in O2

    DEFF Research Database (Denmark)

    Nakao, S.; Stamate, Eugen; Sugai, H.

    2007-01-01

    Plasma parameters in the vicinity of the dielectric window of a low density, microwave discharge produced in 0, at 915 N/FHz are investigated by a spherical probe and optical emission spectroscopy while the microwave field distribution is measured by a spectrum analyzer. The electron energy...

  16. Lithium Coatings on NSTX Plasma Facing Components and Its Effects On Boundary Control, Core Plasma Performance, and Operation

    Energy Technology Data Exchange (ETDEWEB)

    H.W.Kugel, M.G.Bell, H.Schneider, J.P.Allain, R.E.Bell, R Kaita, J.Kallman, S. Kaye, B.P. LeBlanc, D. Mansfield, R.E. Nygen, R. Maingi, J. Menard, D. Mueller, M. Ono, S. Paul, S.Gerhardt, R.Raman, S.Sabbagh, C.H.Skinner, V.Soukhanovskii, J.Timberlake, L.E.Zakharov, and the NSTX Research Team

    2010-01-25

    NSTX high-power divertor plasma experiments have used in succession lithium pellet injection (LPI), evaporated lithium, and injected lithium powder to apply lithium coatings to graphite plasma facing components. In 2005, following wall conditioning and LPI, discharges exhibited edge density reduction and performance improvements. Since 2006, first one, and now two lithium evaporators have been used routinely to evaporate lithium onto the lower divertor region at total rates of 10-70 mg/min for periods 5-10 min between discharges. Prior to each discharge, the evaporators are withdrawn behind shutters. Significant improvements in the performance of NBI heated divertor discharges resulting from these lithium depositions were observed. These evaporators are now used for more than 80% of NSTX discharges. Initial work with injecting fine lithium powder into the edge of NBI heated deuterium discharges yielded comparable changes in performance. Several operational issues encountered with lithium wall conditions, and the special procedures needed for vessel entry are discussed. The next step in this work is installation of a Liquid Lithium Divertor surface on the outer part of the lower divertor.

  17. Plasma protein-binding parameters of prednisolone in immune disease patients receiving long-term prednisone therapy.

    Science.gov (United States)

    Wagner, J G; Wexler, D; Ağabeyoğlu, I T; Bergstrom, R F; Sakmar, E; Kay, D R

    1981-04-01

    Prednisone and prednisolone bind in plasma to albumin and transcortin. In am attempt to determine whether prednisone side effects and/or type of disease correlated with prednisolone plasma protein binding, multiple plasma samples from 17 patients (three asthma, eight SLE, three RA, two PSS, one PAN) receiving long-term prednisone therapy were monitored during an interval between two prednisone doses. Prednisolone plasma protein binding was nonlinear and exhibited large intrapatient and interpatient variability. For the group, mean association constants of the prednisolone-albumin complex and the prednisolone-transcortin complex were 2.3 X 10(3) M-1 and 2.9 X 10(7) M-1, with coefficients of variation of 82% and 127%, respectively. SLE patients tended to have lower mean prednisolone association constants for albumin and transcortin than did other patients. The presence of corticosteroid side effects did not correlate with prednisolone plasma protein-binding parameters. The wide range of prednisolone free fraction noted in plasma from patients who achieved comparable total prednisolone plasma concentrations implies that administration of a uniform prednisone dose will not lead to a predictable clinical response.

  18. Design of operation parameters of a high speed TDI CCD line scan camera

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    This paper analyzes the operation parameters of the time delay and integration (TDI) line scan CCD camera, such as resolution, line rate, clock frequency, etc. and their mathematical relationship is deduced. By analyzing and calculating these parameters, the working clocks of the TDI CCD line scan camera are designed,which guarantees the synchronization of the line scan rate and the camera movement speed. The IL - E2 TDI CCD of DALSA Co. is used as the sensor of the camera in the paper. The working clock generator used for the TDI CCD sensor is realized by using the programmable logic device (PLD). The experimental results show that the working clock generator circuit satisfies the requirement of high speed TDI CCD line scan camera.

  19. Effects of Dietary Supplementation of Some Antioxidants on Liver Antioxidant Status and Plasma Biochemistry Parameters of Heat-Stressed Quail

    Directory of Open Access Journals (Sweden)

    Senay Sarıca

    2017-07-01

    Full Text Available This study aimed to compare the dietary supplementation of oleuropein (O and α-tocopherol acetate (TA alone or with organic selenium (Se on liver antioxidant status and some plasma biochemistry parameters in Japanese quails reared under heat stress (HS. A total of 800, two-weeks old quails were kept in wire cages in the temperature-controlled rooms at either 22°C or 34°C for 8 h/d and fed on a basal diet (NC or the diets supplemented with TA (TA200 or O (O200 at 200 mg/kg alone or with OSe (TA200+OSe and O200+OSe to the NC diet. HS decreased the total antioxidant status (TAS and increased the total oxidative stress (TOS and oxidative stress index (OSI of liver compared to thermoneutral temperature (TN. The TA200, O200, TA200+OSe and O200+OSe diets increased TAS and decreased TOS of liver compared to those of quails fed NC. OSI was decreased by the TA200, O200 and TA200+OSe diets compared to NC and O200+OSe diets. HS reduced plasma albumin (A and total protein (TP concentrations, on the other hand, increased plasma glucose (G, total cholesterol (CHO and triglyceride (TG levels compared to TN. The TA200, O200, TA200+OSe and O200+OSe diets reduced plasma total CHO and TG levels and increased plasma A level. The TA200 and TA200+OSe diets reduced plasma G level and increased plasma TP levels compared to those of quails fed the other diets. In conclusion, dietary supplementation of vitamin E and oleuropein alone or with organic selenium is necessary to remove the negative effects of heat stress on liver antioxidant status and some plasma parameters of quails.

  20. The effect of He-ash poisoning on L-mode and high ? operations in ITER-like plasma

    Science.gov (United States)

    Tateishi, G.; Itoh, S. I.; Yagi, M.

    1997-11-01

    The burning performance of the self-ignited steady-state plasma is investigated based on a point model. For the ITER-like parameters, the theoretical model scaling law 0741-3335/39/11/008/img7, which could explain the characteristics of the L-mode and the high 0741-3335/39/11/008/img8 fairly well, and the effect of He-ash poisoning are introduced simultaneously. The solutions are obtained by solving the particle and energy balance equations in steady-state conditions, taking account of the effect of radiation loss due to He ash and fuel ions. Typically, there exist four solutions of the plasma current at fixed temperature. The divergence of the temperature, which is predicted by a previous study (Fukuyama et al 1995 Nucl. Fusion 35 1669) for the pure plasma in the high 0741-3335/39/11/008/img8, disappears under the influence of He ash. In the low-density limit, the L-mode branches and the high 0741-3335/39/11/008/img8 branches are well separated on the plane of the current and the temperature. On the other hand, the merging of two branches occurs at higher densities due to the nonlinear effect contained in the scaling law. Examining the constraints imposed on the core plasma (the density limit, the 0741-3335/39/11/008/img11 limit and so on), we found that the self-ignited state of the high 0741-3335/39/11/008/img8 operation would be difficult.

  1. Adaptive Synchronization of Chaotic Systems considering Performance Parameters of Operational Amplifiers

    Directory of Open Access Journals (Sweden)

    Sergio Ruíz-Hernández

    2015-01-01

    Full Text Available This paper addresses an adaptive control approach for synchronizing two chaotic oscillators with saturated nonlinear function series as nonlinear functions. Mathematical models to characterize the behavior of the transmitter and receiver circuit were derived, including in the latter the adaptive control and taking into account, for both chaotic oscillators, the most influential performance parameters associated with operational amplifiers. Asymptotic stability of the full synchronization system is studied by using Lyapunov direct method. Theoretical derivations and related results are experimentally validated through implementations from commercially available devices. Finally, the full synchronization system can easily be reproducible at a low cost.

  2. Study of operational parameters impacting helicopter fuel consumption. [using computer techniques (computer programs)

    Science.gov (United States)

    Cross, J. L.; Stevens, D. D.

    1976-01-01

    A computerized study of operational parameters affecting helicopter fuel consumption was conducted as an integral part of the NASA Civil Helicopter Technology Program. The study utilized the Helicopter Sizing and Performance Computer Program (HESCOMP) developed by the Boeing-Vertol Company and NASA Ames Research Center. An introduction to HESCOMP is incorporated in this report. The results presented were calculated using the NASA CH-53 civil helicopter research aircraft specifications. Plots from which optimum flight conditions for minimum fuel use that can be obtained are presented for this aircraft. The results of the study are considered to be generally indicative of trends for all helicopters.

  3. Effect of Mixing and Other Operating Parameters in Sol-Gel Processes

    OpenAIRE

    Marchisio, Daniele L.; Omegna, Federica; Barresi, Antonello A.; Bowen, Paul

    2008-01-01

    In this work the effect of mixing on a sol-gel process is quantitatively investigated. Titanium dioxide synthesis from titanium tetra-isopropoxide is used as a test reaction. Solutions of titanium alkoxide in isopropyl alcohol and water in isopropyl alcohol are mixed in a special mixing device (i.e., vortex reactor) at different mixing rates, and the effect of mixing is quantified and compared with the effect of the other relevant operating parameters, namely the water to alkoxide, acid to a...

  4. Operation parameters of a small scale batch distillation column for hydrous ethanol fuel (HEF production

    Directory of Open Access Journals (Sweden)

    F. D. Mayer

    2015-04-01

    Full Text Available Batch distillation applied to hydrous ethanol fuel (HEF production on a small scale still requires operating conditions that ensure optimal top product quality and productivity. The aim of this study is to statistically validate a batch still through the employment of response surface methodology (RSM. Operational and productivity parameters were formulated in order to guarantee quality compliance with the legal requirements for the top product concentration, besides providing support information to control the production of HEF on a small scale. The reboiler control and dephlegmator temperatures maintained within the range of 97.5 to 99.5°C and 60 to 70°C, respectively, combined with a variable reflux ratio, was satisfactory in obtaining a top product concentration, in accordance with legal regulations, as well as high productivity. The results of this study may contribute to the assembly of a simple and low-cost batch distillation control system.

  5. Pulsed Mode Operation and Longitudinal Parameter Measurement of the Rossendorf SRF Gun

    CERN Document Server

    Teichert, J; Buettig, H; Justus, M; Lehnert, U; Michel, P; Schamlott, A; Schneider, Ch; Schurig, R; Xiang, R; Klemz, G; Kamps, T; Rudolph, J; Schenk, M; Will, I

    2011-01-01

    The Rossendorf SRF gun with a 3½ cell cavity has been operated since 2007. It has produced CW beam with the electron energy of 3 MeV and the average current up to 16 μA. The electron beam of the gun has been successfully injected into the ELBE superconducting linac since 2010. The Nb cavity has shown constant quality during the operation and for the Cs2Te photocathode life time of months could be obtained. Recently the gun started to run in the pulsed mode with higher gradient. The longitudinal Parameters have been measured in this mode. The dark current arose from the high gradient is studied. The main field emission source has been found to be the half cell. In this paper the new status of the SRF gun will be presented, and the latest results of the beam experiments will be discussed.

  6. Study of the impact of environmental parameters on the operation of CMS RPCs

    CERN Document Server

    Assran, Yasser

    2011-01-01

    CMS (Compact Muon Solenoid) is a general purpose detector designed to run at the highest luminosity at Large Hadron Collider (LHC), CERN, Geneva, Switzerland. The muon system of the CMS experiment relies on Drift Tubes (DT), Cathode Strip Chambers (CSC) and Resistive Plate Chambers (RPC). RPCs are dedicated for the first level muon trigger and they are characterized by bakelite electrodes delimited in a specialized gas volume filled with operational gas mixture. This analysis has been done for the RPC chambers installed in CMS experiment at CERN. The Currents of CMS RPCs chambers are analyzed as a function of environmental parameters such as Temperature, Humidity and pressure, which are important for the operation of the muon detector system. A novel Neural Network approach has been used to analyze the data and to build a model using experimental measurements and combining the results of the simulations. Data from RPC Chambers in CMS experiment are taken and compared to the results from neural Network.

  7. Influence of laser design parameters on the hydrodynamics of microfusion plasmas; Influencia de los parametros basicos del laser sobre la hidrodinamica de plasmas para microfusion

    Energy Technology Data Exchange (ETDEWEB)

    Sanmartin, J. A.; Barrero, A.

    1976-07-01

    The quasi neutral, one dimensional motion generated in a cold, infinite, uniform plasma of density n{sub 0}, by the absorption, In a given plane, of a linear pulse of energy per unit time and area {phi} - {phi}{sub 0}t/{tau}, 0< t {<=} {tau}, is considered; the analysis allows for thermal conduction and viscosity of ions and electrons, their energy exchange, and an electron thermal flux limiter. The motion is found to be self similar and governed by single non dimensional parameter {alpha} similar{sub t}o(n{sup 2}{sub 0} {tau}/{phi}{sub 0}){sup 2}/3. Detailed asymptotic results are obtained for both {alpha}<<1and {alpha}>>1; the general (behaviour of the solution for arbitrary {alpha} is discussed. The analysis can be easily extended to the case of a plasma initially occupying a half-space, and throws light on the hydrodynamics of laser fusion plasmas. (Author) 51 refs.

  8. Investigation of operational parameters for an industrial CFB combustor of coal, biomass and sludge

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The combustion of coal and/or biomass (sludge, wood waste, RDF, etc.) in a circulating fluidized bed has been a commercial topper for over 20 years, and references to principles and applications are numerous and widespread although few data are presented concerning the operation of large scale CFB-units. The authors studied the CFB-combustion at UPM-Kymmene (Ayr), a major paper mill relying for its steam production upon the combustion of coal (80-85%), wood bark (5-10%) and wastewater treatment sludge (5-10%). The maximum capacity of the CFB is 58 MWth.A complete diagnostic of the operation was made, and additional tests were performed to assess the operating mode. The plant schematics,relevant dimensions and process data are given. To assess the operation of the UPM-CFB, it is important to review essential design parameters and principles of CFB combustors, which will be discussed in detail to include required data, heat balance and flowrates, operating versus transport velocity, kinetics and conversion (including the possible effect of the Bouduard reaction if carbon is present).Since the residence time in the riser and the cyclone efficiency determine the burnout of circulating fuel-particles, the UPM-CFB was subjected to a stimulus response technique using nickel oxide as tracer. Results illustrate the efficiency of the cyclone separation and the number of recycle loops for particles of a given size. Results will also be used to assess the cyclone operation and efficiency and to comment upon expected and measured carbon conversion.

  9. Design and operational parameters of a rooftop rainwater harvesting system: definition, sensitivity and verification.

    Science.gov (United States)

    Mun, J S; Han, M Y

    2012-01-01

    The appropriate design and evaluation of a rainwater harvesting (RWH) system is necessary to improve system performance and the stability of the water supply. The main design parameters (DPs) of an RWH system are rainfall, catchment area, collection efficiency, tank volume and water demand. Its operational parameters (OPs) include rainwater use efficiency (RUE), water saving efficiency (WSE) and cycle number (CN). The sensitivity analysis of a rooftop RWH system's DPs to its OPs reveals that the ratio of tank volume to catchment area (V/A) for an RWH system in Seoul, South Korea is recommended between 0.03 and 0.08 in terms of rate of change in RUE. The appropriate design value of V/A is varied with D/A. The extra tank volume up to V/A of 0.15∼0.2 is also available, if necessary to secure more water. Accordingly, we should figure out suitable value or range of DPs based on the sensitivity analysis to optimize design of an RWH system or improve operation efficiency. The operational data employed in this study, which was carried out to validate the design and evaluation method of an RWH system, were obtained from the system in use at a dormitory complex at Seoul National University (SNU) in Korea. The results of these operational data are in good agreement with those used in the initial simulation. The proposed method and the results of this research will be useful in evaluating and comparing the performance of RWH systems. It is found that RUE can be increased by expanding the variety of rainwater uses, particularly in the high rainfall season.

  10. Nonlinear Sum Operator Equations with a Parameter and Application to Second-Order Three-Point BVPs

    Directory of Open Access Journals (Sweden)

    Wen-Xia Wang

    2014-01-01

    Full Text Available A class of nonlinear sum operator equations with a parameter on order Banach spaces were considered. The existence and uniqueness of positive solutions for this kind of operator equations and the dependence of solutions on the parameter have been obtained by using the properties of cone and nonlinear analysis methods. The critical value of the parameter was estimated. Further, the application to some nonlinear three-point boundary value problems was given to show the significance of the discussion.

  11. APNTP Inactivation of MS2 Bacteriophage: Effect of operating parameters on virucidal activity

    Science.gov (United States)

    Alshraiedeh, Nid'a.; Alkawareek, Mahmoud; Gorman, Sean; Graham, William; Gilmore, Brendan

    2013-09-01

    Atmospheric pressure non-thermal plasmas (APNTP) provide a promising alternative method for surface decontamination. Norovirus is globally the most common etiological agent of acute non-bacterial gastroenteritis outbreaks. APNTP have proven to be effective in inactivation of MS2 bacteriophages, widely employed as surrogate for human norovirus. Here we explore the optimization of a helium-based kHz APNTP by varying the oxygen concentration (from 0 to 0.75%) in the feed gas and the operating frequency (from 10 to 40 kHz). It has been established that both these changes increase the reactive oxide concentration in the plume and we see a correlation between both increasing oxygen concentration and operating frequency and reduction in survival density of treated bacteriophages. For example increasing the O2 concentration from 0 to 0.5 to 0.75% increased the log reduction from 4.98 to 5.93 to 7.06, respectively. These results will be discussed in the context of recent studies where singlet delta oxygen was shown to cause MS2 phage inactivation., Q T Algwari, PhD Thesis QUB (2011).

  12. Effect of the initial plasma parameters on the structure of the current sheets developing in two-dimensional magnetic fields with a null line

    Science.gov (United States)

    Ostrovskaya, G. V.; Frank, A. G.; Bogdanov, S. Yu.

    2010-07-01

    The effect of the initial plasma parameters on the structure of the plasma of the current sheets that form in two-dimensional magnetic fields with a null line is studied by holographic interferometry. The evolution of the plasma sheets that develop in an initial low-density plasma, where a gas is mainly ionized by a pulse current passing through the plasma and initiating the formation of a current sheet, has been comprehensively studied for the first time. At the early stage of evolution, the spatial structure of such a plasma sheet differs substantially from the classic current sheets forming in a dense plasma. Nevertheless, extended plasma sheets with similar parameters form eventually irrespective of the initial plasma density.

  13. Investigation of the effect of laser parameters on the target, plume and plasma behavior during and after laser-solid interaction

    Science.gov (United States)

    Stancalie, A.; Ciobanu, S. S.; Sporea, D.

    2017-09-01

    A detailed theoretical and experimental analysis is performed for a wide range of laser operating conditions, typical for laser induced breakdown spectroscopy (LIBS) and laser ablation (LA) experiments on copper metallic target. The plasma parameters were experimentally estimated from the line intensities ratio which reflects the relative population of neutral excited species in the plasma. In the case of LA experiments the highest temperature observed was 8210 ± 370 K. In case of LIBS measurements, a maximum temperature of 8123 K has been determined. The experimental results are in good agreement with a stationary, hydrodynamic model. We have theoretically investigated the plasma emission based on the generalized collisional-radiative model as implemented in the ADAS interconnected set of computer codes and data collections. The ionic population density distribution over the ground and excited states into the cooper plasma is graphically displayed as output from the code. The theoretical line intensity ratios are in good agreement with experimental values for the electron density and temperature range measured in our experiments.

  14. Detection of Independent Associations of Plasma Lipidomic Parameters with Insulin Sensitivity Indices Using Data Mining Methodology

    Science.gov (United States)

    Schuhmann, Kai; Xu, Aimin; Schulte, Klaus-Martin; Simeonovic, Charmaine J.; Schwarz, Peter E. H.; Bornstein, Stefan R.; Shevchenko, Andrej; Graessler, Juergen

    2016-01-01

    Objective Glucolipotoxicity is a major pathophysiological mechanism in the development of insulin resistance and type 2 diabetes mellitus (T2D). We aimed to detect subtle changes in the circulating lipid profile by shotgun lipidomics analyses and to associate them with four different insulin sensitivity indices. Methods The cross-sectional study comprised 90 men with a broad range of insulin sensitivity including normal glucose tolerance (NGT, n = 33), impaired glucose tolerance (IGT, n = 32) and newly detected T2D (n = 25). Prior to oral glucose challenge plasma was obtained and quantitatively analyzed for 198 lipid molecular species from 13 different lipid classes including triacylglycerls (TAGs), phosphatidylcholine plasmalogen/ether (PC O-s), sphingomyelins (SMs), and lysophosphatidylcholines (LPCs). To identify a lipidomic signature of individual insulin sensitivity we applied three data mining approaches, namely least absolute shrinkage and selection operator (LASSO), Support Vector Regression (SVR) and Random Forests (RF) for the following insulin sensitivity indices: homeostasis model of insulin resistance (HOMA-IR), glucose insulin sensitivity index (GSI), insulin sensitivity index (ISI), and disposition index (DI). The LASSO procedure offers a high prediction accuracy and and an easier interpretability than SVR and RF. Results After LASSO selection, the plasma lipidome explained 3% (DI) to maximal 53% (HOMA-IR) variability of the sensitivity indexes. Among the lipid species with the highest positive LASSO regression coefficient were TAG 54:2 (HOMA-IR), PC O- 32:0 (GSI), and SM 40:3:1 (ISI). The highest negative regression coefficient was obtained for LPC 22:5 (HOMA-IR), TAG 51:1 (GSI), and TAG 58:6 (ISI). Conclusion Although a substantial part of lipid molecular species showed a significant correlation with insulin sensitivity indices we were able to identify a limited number of lipid metabolites of particular importance based on the LASSO approach. These

  15. Optimization of Design Parameters and Operating Conditions of Electrochemical Capacitors for High Energy and Power Performance

    Science.gov (United States)

    Ike, Innocent S.; Sigalas, Iakovos; Iyuke, Sunny E.

    2017-03-01

    Theoretical expressions for performance parameters of different electrochemical capacitors (ECs) have been optimized by solving them using MATLAB scripts as well as via the MATLAB R2014a optimization toolbox. The performance of the different kinds of ECs under given conditions was compared using theoretical equations and simulations of various models based on the conditions of device components, using optimal values for the coefficient associated with the battery-kind material ( K BMopt) and the constant associated with the electrolyte material ( K Eopt), as well as our symmetric electric double-layer capacitor (EDLC) experimental data. Estimation of performance parameters was possible based on values for the mass ratio of electrodes, operating potential range ratio, and specific capacitance of electrolyte. The performance of asymmetric ECs with suitable electrode mass and operating potential range ratios using aqueous or organic electrolyte at appropriate operating potential range and specific capacitance was 2.2 and 5.56 times greater, respectively, than for the symmetric EDLC and asymmetric EC using the same aqueous electrolyte, respectively. This enhancement was accompanied by reduced cell mass and volume. Also, the storable and deliverable energies of the asymmetric EC with suitable electrode mass and operating potential range ratios using the proper organic electrolyte were 12.9 times greater than those of the symmetric EDLC using aqueous electrolyte, again with reduced cell mass and volume. The storable energy, energy density, and power density of the asymmetric EDLC with suitable electrode mass and operating potential range ratios using the proper organic electrolyte were 5.56 times higher than for a similar symmetric EDLC using aqueous electrolyte, with cell mass and volume reduced by a factor of 1.77. Also, the asymmetric EDLC with the same type of electrode and suitable electrode mass ratio, working potential range ratio, and proper organic electrolyte

  16. Measuring the parameters of a high flux plasma in Proto-MPEX

    Science.gov (United States)

    Skeen, C.; Biewer, T. M.; Cantrell, C. L.; Klemm, J. C.; Musick, R. A.; Nunley, G.; Salazar Sanchez, J. S.; Sawyer, D. J.; Ray, H.; Shaw, G.; Showers, M.

    2016-10-01

    The Prototype Material Plasma Exposure Experiment (Proto-MPEX) is a linear, magnetically confined plasma production device, utilizing a helicon antenna. The plasma column interacts with a material target at the end of the device, creating plasma-material interaction conditions that are relevant to the conditions that are expected in future fusion reactors. Moreover, helicon antenna plasma sources have been proposed as propulsion devices for spacecraft. It has been observed that in some circumstances the Proto-MPEX plasma exerts sufficient force on the target plate to cause the target to recoil. A ballistic probe has been designed to measure the force and heat flux profile of the plasma. The probe response has been calibrated, using scales, thermocouples, and fast camera imaging. The ballistic probe has been inserted into Proto-MPEX plasmas and the heat flux profile of the plasma has been measured. Also the maximum force that is exerted on the probe has been estimated. This work was supported by the US. D.O.E. contract DE-AC05-00OR22725, and the Oak Ridge Associated Universities ARC program.

  17. Pulsed Plasma Thruster (PPT) Technology: Earth Observing-1 PPT Operational and Advanced Components Being Developed

    Science.gov (United States)

    Pencil, Eric J.; Benson, Scott W.; Arrington, Lynn A.; Frus, John; Hoskins, W. Andrew; Burton, Rodney

    2003-01-01

    In 2002 the pulsed plasma thruster (PPT) mounted on the Earth Observing-1 spacecraft was operated successfully in orbit. The two-axis thruster system is fully incorporated in the attitude determination and control system and is being used to automatically counteract disturbances in the pitch axis of the spacecraft. The first tests conducted in space demonstrated the full range of PPT operation, followed by calibration of control torques from the PPT in the attitude control system. Then the spacecraft was placed in PPT control mode. To date, it has operated for about 30 hr. The PPT successfully controlled pitch momentum during wheel de-spin, solar array acceleration and deceleration during array rewind, and environmental torques in nominal operating conditions. Images collected with the Advanced Landsat Imager during PPT operation have demonstrated that there was no degradation in comparison to full momentum wheel control. In addition, other experiments have been performed to interrogate the effects of PPT operation on communication packages and light reflection from spacecraft surfaces. Future experiments will investigate the possibility of orbit-raising maneuvers, spacecraft roll, and concurrent operation with the Hyperion imager. Future applications envisioned for pulsed plasma thrusters include longer life, higher precision, multiaxis thruster configurations for three-axis attitude control systems or high-precision, formationflying systems. Advanced components, such as a "dry" mica-foil capacitor, a wear-resistant spark plug, and a multichannel power processing unit have been developed under contract with Unison Industries, General Dynamics, and C.U. Aerospace. Over the last year, evaluation tests have been conducted to determine power processing unit efficiency, atmospheric functionality, vacuum functionality, thruster performance evaluation, thermal performance, and component life.

  18. Plasma characteristics of argon glow discharge produced by AC power supply operating at low frequencies

    Energy Technology Data Exchange (ETDEWEB)

    Kongpiboolkid, Watcharapon; Mongkolnavin, Rattachat [Department of Physics, Facuty of Science, Chulalongkorn University, Bangkok (Thailand); Plasma Technology and Nuclear Fusion Research Unit, Chulalongkorn University, Bangkok (Thailand)

    2015-04-24

    Non-thermal properties of Argon glow discharge operating with various operating pressures were measured and presented in this work. The Argon plasma is produced by a parallel conducting electrodes coupling with a high voltage AC power supply. The power supply can generate high AC voltage at various frequencies. The frequencies for the operation are in the range of a few kHz. The system is capable of generating electric field between the two metal electrodes discharge system. The characteristics of plasma produced were measured by optical emission spectroscopy (OES) technique where electron temperature (T{sub e}) and electron number density (n{sub e}) can be determined by line intensity ratio method. The value of electron number density was then determined from the Saha-Eggert equation. Our results show that the electron number density of the discharge obtained is of the order of 10{sup −17} − 10{sup −18} m{sup −3} where the electron temperature is between 1.00−2.00 eV for various operating frequencies used which are in good agreement with similar results published earlier.

  19. The influence of operational parameters and feed preparation in a convective batch ribbon powder mixer.

    Science.gov (United States)

    Yeow, Sin Tung; Shahar, Asnawi; Abdul Aziz, Norashikin; Anuar, Mohd Shamsul; Yusof, Yus Aniza; Taip, Farah Saleena

    2011-01-01

    To investigate the effect of feed preparation characteristics and operational parameters on mixing homogeneity in a convective batch ribbon mixer. Lactose 100M, lactose 200M, ascorbic acid, and zinc oxide powders were used for the mixing study. Operational parameters studied were rotational speed and mixing time. The feed preparations studied were the use of preblending and the particle size of the feed materials. The blends of ascorbic acid, zinc oxide, and lactose were prepared with preblending and without preblending, prior to mixing at different blender rotation speeds and mixing times. Chemical tests were performed to measure the homogeneity of the ascorbic acid in the model mixture. With preblending, a mixture with lactose 200M achieved the required homogeneity in a shorter period of time at a lower rotational speed. The results indicated that the homogeneity of the mixtures was influenced by the blender rotation speed and mixing time. Better mixing can be obtained with higher rotation speeds and longer mixing time. It was also observed that preblending and smaller feed particle size achieved the required homogeneity in a shorter period of time at a lower rotational speed. These results illustrate that using binders with a smaller particle size and a preblending technique improves the mixing process in a convective batch ribbon powder mixer. However, prolonged periods of high-speed mixing will lead to mixture segregation.

  20. Performance Optimization of Spin-Torque Microwave Detectors with Material and Operational Parameters

    Directory of Open Access Journals (Sweden)

    X. Li

    2016-01-01

    Full Text Available Sensitivity, bandwidth, and noise equivalent power (NEP are important indicators of the performance of microwave detectors. The previous reports on spin-torque microwave detectors (STMDs have proposed various approaches to increase the sensitivity. However, the effects of these methods on the other two indicators remain unclear. In this work, macrospin simulation is developed to evaluate how the performance can be optimized through changing the material (tilt angle of reference-layer magnetization and operational parameters (the direction of magnetic field and working temperature. The study on the effect of magnetic field reveals that the driving force behind the performance tuning is the effective field and the equilibrium angle between the magnetization of the free layer and that of the reference layer. The material that offers the optimal tilt angle in reference-layer magnetization is determined. The sensitivity can be further increased by changing the direction of the applied magnetic field and the operation temperature. Although the optimized sensitivity is accompanied by a reduction in bandwidth or an increase in NEP, a balance among these performance indicators can be reached through optimal tuning of the corresponding influencing parameters.

  1. Effects of operational parameters on emission performance and combustion efficiency in small-scale CFBCs

    Energy Technology Data Exchange (ETDEWEB)

    Gungor, A.; Eskin, N. [Nigde University, Nigde (Turkey). Faculty of Engineering & Architecture

    2008-11-15

    A well-designed CFBC can burn coal with high efficiency and within acceptable levels of gaseous emission. In this theoretical study effects of operational parameters on combustion efficiency and the pollutants emitted have been estimated using a developed dynamic 2D (two-dimensional) model for CFBCs. Model simulations have been carried out to examine the effect of different operational parameters such as excess air and gas inlet pressure and coal particle size on bed temperature, the overall CO, NOx and SO{sub 2} emissions and combustion efficiency from a small-scale CFBC. It has been observed that increasing excess air ratio causes fluidized bed temperature decrease and CO emission increase. Coal particle size has more significant effect on CO emissions than the gas inlet pressure all the entrance to fluidized bed. Increasing excess air ratio leads to decreasing SO{sub 2} and NOx emissions. The gas inlet pressure at the entrance to fluidized bed has a more significant effect on NOx emission than the coal particle size. Increasing excess air causes decreasing combustion efficiency. The gas inlet pressure has more pronounced effect on combustion efficiency than the coal particle size, particularly at higher excess air ratios. The developed model is also validated in terms of combustion efficiency with experimental literature data obtained from 300 kW laboratory scale test unit. The present theoretical study also confirms that CFB combustion allows clean and efficient combustion of coal.

  2. Influence of plasma parameters on the growth and properties of magnetron sputtered CNx thin films

    Science.gov (United States)

    Hellgren, Niklas; Macák, Karol; Broitman, Esteban; Johansson, Mats P.; Hultman, Lars; Sundgren, Jan-Eric

    2000-07-01

    Carbon nitride CNx thin films were grown by unbalanced dc magnetron sputtering from a graphite target in a pure N2 discharge, and with the substrate temperature Ts kept between 100 and 550 °C. A solenoid coil positioned in the vicinity of the substrate was used to support the magnetic field of the magnetron, so that the plasma could be increased near the substrate. By varying the coil current and gas pressure, the energy distribution and fluxes of N2+ ions and C neutrals could be varied independently of each other over a wide range. An array of Langmuir probes in the substrate position was used to monitor the radial ion flux distribution over the 75-mm-diam substrate, while the flux and energy distribution of neutrals was estimated through Monte Carlo simulations. The structure, surface roughness, and mechanical response of the films are found to be strongly dependent on the substrate temperature, and the fluxes and energies of the deposited particles. By controlling the process parameters, the film structure can thus be selected to be amorphous, graphite-like or fullerene-like. When depositing at 3 mTorr N2 pressure, with Ts>200 °C, a transition from a disordered graphite-like to a hard and elastic fullerene-like structure occurred when the ion flux was increased above ˜0.5-1.0 mA/cm2. The nitrogen-to-carbon concentration ratio in the films ranged from ˜0.1 to 0.65, depending on substrate temperature and gas pressure. The nitrogen film concentration did, however, not change when varying the nitrogen ion-to-carbon atom flux ratios from ˜1 to 20.

  3. Characterization of the Basic Operational Properties of the Capillary Plasma Electrode (CPE) Discharge

    Science.gov (United States)

    Lopez, Jose; Zhu, Weidong; Figus, Margaret; Becker, Kurt

    2008-10-01

    Various approaches have been pursued to create stable atmospheric pressure discharges by extending the lifetime of the diffuse phase of the discharge to hundreds of microseconds. Previous research showed that the stability of the diffuse mode is dependent on the frequency (in the kHz range), gas type, power, mode of the excitation, and geometrical confinement. The Capillary Plasma Electrode (CPE) discharge is able to produce stable atmospheric pressure nonequilibrium plasmas. The CPE is similar in design to a barrier-electrode discharge, but has perforated dielectrics. This configuration, aside from exhibiting a diffuse mode of operation, also exhibits the so-called ``capillary jet'' mode, in which the capillaries ``turn on'' and a bright plasma jet emerges from the capillaries. The capillary jets from adjacent capillaries overlap so that the discharge appears uniform when the electrode contains an array of holes. There appears to be a threshold frequency for the capillary jet formation, which is strongly dependent on the L/D ratio of the capillaries, where D is the diameter of a capillary and L its length. This current work explores these modes of operation of the CPE by characterizing the electrical and optical emission properties of this discharge.

  4. DESIGN OF INTELLIGENT CONTROL SYSTEM USING ACOUSTIC PARAMETERS FOR GRINDING MILL OPERATION

    Directory of Open Access Journals (Sweden)

    Sonali Sen

    2013-02-01

    Full Text Available This paper utilizes acoustic parameters such as FS,NC, N, P, INC, FL, FH, W for acoustic signals S of different running conditions of a ballmill to deriveout the acoustic signatures and hence control signals, which is to be used for designing the control systems of the mill. The parameters FS, NC, N, P, INC, FL, FH and W are represented by sample rate in Hz, number of cepstral coefficients, length of frame in samples, number of filters in filter bank, frame increment, low end of the lowest filter, high end of highest filter and the window over which the analysis is to be performed respectively. The work establishes an appropriate theoretical background that helps to predict dynamic breakage characteristics with respect to particle size distribution of materials, adequately supported by experimental data. The signatures of different running conditions of grinding mill have been extracted from the captured signal in time frame these have been used as feedback signal to monitor the grinding operation. Condenser based microphones have been used for capturing acoustic signals in time domain directly in computers and stored for further analysis. Matlab R2010b has been used for different analysis of the experiment. On analyzing the signatures, it has been observed whether the fines are produced progressively to attain the desired size range or the mill producing undesired products. Thus, the approach has been used in this paper has the ability to arrive in the stage of optimum grinding by tuning parameters of the mill in real time, and also it can prevent the mill to enter into an erroneous state. Moreover, on study it has found that the present scheme can be used more accurately in comparison to the earlier work of the author. This paper presents an implementation scheme to use acoustic signal as the control signal to regulate the operation of a grinding mill.

  5. Determining the optimum process parameter for grinding operations using robust process

    Energy Technology Data Exchange (ETDEWEB)

    Neseli, Suley Man; Asilturk, Ilhan; Celik, Levent [Univ. of Selcuk, Konya (Turkmenistan)

    2012-11-15

    We applied combined response surface methodology (RSM) and Taguchi methodology (TM) to determine optimum parameters for minimum surface roughness (Ra) and vibration (Vb) in external cylindrical grinding. First, an experiment was conducted in a CNC cylindrical grinding machine. The TM using L{sup 27} orthogonal array was applied to the design of the experiment. The three input parameters were workpiece revolution, feed rate and depth of cut; the outputs were vibrations and surface roughness. Second, to minimize wheel vibration and surface roughness, two optimized models were developed using computer aided single objective optimization. The experimental and statistical results revealed that the most significant grinding parameter for surface roughness and vibration is workpiece revolution followed by the depth of cut. The predicted values and measured values were fairly close, which indicates 2 ( 94.99 R{sup 2Ra}=and 2 92.73) R{sup 2Vb}=that the developed models can be effectively used to predict surface roughness and vibration in the grinding. The established model for determination of optimal operating conditions shows that a hybrid approach can lead to success of a robust process.

  6. Investigations on the transition between column and micropinch mode of plasma focus operation

    Science.gov (United States)

    Lebert, R.; Engel, A.; Neff, W.

    1995-12-01

    X-ray emission from pinch plasma devices with pinch currents ranging from 200 to 400 kA operated with pure high-Z gases are investigated with temporal spatial and spectral resolution. If operated using elements Zneon) K-shell emission is observed from column-like volumes several 100 μm in diameter and several mm in length (bulk or column mode). For Z≳18 (e.g., krypton or xenon) emission with hν≳1 keV is only observed from micropinches. For argon (Z=18) both modes of operation can be observed. The occurrence of a specific mode depends on the initial gas pressure. In this paper the transition regime between column and micropinches is investigated with particular regard to argon. A criterion is proposed to decide whether column mode or micropinch mode is expected.

  7. Introduction to Plasma Physics

    Science.gov (United States)

    Gurnett, Donald A.; Bhattacharjee, Amitava

    2017-03-01

    Preface; 1. Introduction; 2. Characteristic parameters of a plasma; 3. Single particle motions; 4. Waves in a cold plasma; 5. Kinetic theory and the moment equations; 6. Magnetohydrodynamics; 7. MHD equilibria and stability; 8. Discontinuities and shock waves; 9. Electrostatic waves in a hot unmagnetized plasma; 10. Waves in a hot magnetized plasma; 11. Nonlinear effects; 12. Collisional processes; Appendix A. Symbols; Appendix B. Useful trigonometric identities; Appendix C. Vector differential operators; Appendix D. Vector calculus identities; Index.

  8. Nicotine, cotinine, and trans-3-hydroxycotinine levels in seminal plasma of smokers: effects on sperm parameters.

    Science.gov (United States)

    Pacifici, R; Altieri, I; Gandini, L; Lenzi, A; Pichini, S; Rosa, M; Zuccaro, P; Dondero, F

    1993-10-01

    Sperm samples from 44 cigarette smokers and 50 nonsmokers attending an infertility clinic were examined by high-performance liquid chromatography (HPLC) assay and HPLC-mass spectrometry for the presence of nicotine (NIC), cotinine (COT), and trans-3'-hydroxycotinine (THOC) in seminal plasma. Smokers were found to have levels of COT and THOC in seminal plasma that were similar to those found in serum. The level of NIC was significantly increased in seminal plasma compared to serum. Total motility of spermatozoa was significantly and negatively correlated to COT and THOC levels in seminal plasma. Forward motility of spermatozoa was correlated only with cotinine semen levels. On the basis of these results, we suggest that the presence of tobacco smoke constituents in seminal plasma could provide a warning of the adverse effects of cigarette smoke on the physiology of reproduction.

  9. Current distribution measurements inside an electromagnetic plasma gun operated in a gas-puff mode.

    Science.gov (United States)

    Poehlmann, Flavio R; Cappelli, Mark A; Rieker, Gregory B

    2010-12-01

    Measurements are presented of the time-dependent current distribution inside a coaxial electromagnetic plasma gun. The measurements are carried out using an array of six axially distributed dual-Rogowski coils in a balanced circuit configuration. The radial current distributions indicate that operation in the gas-puff mode, i.e., the mode in which the electrode voltage is applied before injection of the gas, results in a stationary ionization front consistent with the presence of a plasma deflagration. The effects of varying the bank capacitance, transmission line inductance, and applied electrode voltage were studied over the range from 14 to 112 μF, 50 to 200 nH, and 1 to 3 kV, respectively.

  10. Current distribution measurements inside an electromagnetic plasma gun operated in a gas-puff mode

    Science.gov (United States)

    Poehlmann, Flavio R.; Cappelli, Mark A.; Rieker, Gregory B.

    2010-12-01

    Measurements are presented of the time-dependent current distribution inside a coaxial electromagnetic plasma gun. The measurements are carried out using an array of six axially distributed dual-Rogowski coils in a balanced circuit configuration. The radial current distributions indicate that operation in the gas-puff mode, i.e., the mode in which the electrode voltage is applied before injection of the gas, results in a stationary ionization front consistent with the presence of a plasma deflagration. The effects of varying the bank capacitance, transmission line inductance, and applied electrode voltage were studied over the range from 14 to 112 μF, 50 to 200 nH, and 1 to 3 kV, respectively.

  11. Effect of applying static electric field on the physical parameters and dynamics of laser-induced plasma

    Directory of Open Access Journals (Sweden)

    Asmaa Elhassan

    2010-04-01

    Full Text Available In order to improve the performance of the LIBS technique – in particular its sensitivity, reproducibility and limit of detection – we studied the effect of applying a static electric field with different polarities on the emission spectra obtained in a typical LIBS set-up. The physical parameters of the laser-induced plasma, namely the electron density Ne and the plasma temperature Te, were studied under such circumstances. In addition to the spectroscopic analysis of the plasma plume emission, the laser-induced shock waves were exploited to monitor the probable changes in the plasma plume dynamics due to the application of the electric field. The study showed a pronounced enhancement in the signal-to-noise (S/N ratio of different Al, neutral and ionic lines under forward biasing voltage (negative target and positive electrode. On the other hand, a clear deterioration of the emission line intensities was observed under conditions of reversed polarity. This negative effect may be attributed to the reduction in electron-ion recombinations due to the stretched plasma plume. The plasma temperature showed a constant value in the average with the increasing electric field in both directions. This effect may be due to the fact that the measured values of Te were averaged over the whole plasma emission volume. The electron density was observed to decrease slightly in the case of forward biasing while no significant effect was noticed in the case of reversed biasing. This slight decrease in Ne can be interpreted in view of the increase in the rate of electron–ion recombinations due to the presence of the electric field. No appreciable effects of the applied electric field on the plasma dynamics were noticed.

  12. Temperature effect on hydrocarbon deposition on molybdenum mirrors under ITER-relevant long-term plasma operation

    NARCIS (Netherlands)

    Rapp, J.; van Rooij, G. J.; Litnovsky, A.; Marot, L.; De Temmerman, G.; Westerhout, J.; Zoethout, E.

    2009-01-01

    Optical diagnostics in ITER will rely on mirrors near the plasma and the deterioration of the reflectivity is a concern. The effect of temperature on the deposition efficiency of hydrocarbons under long-term operation conditions similar to ITER was investigated in the linear plasma generator

  13. Temperature effect on hydrocarbon deposition on molybdenum mirrors under ITER-relevant long-term plasma operation

    NARCIS (Netherlands)

    Rapp, J.; van Rooij, G. J.; Litnovsky, A.; Marot, L.; De Temmerman, G.; Westerhout, J.; Zoethout, E.

    2009-01-01

    Optical diagnostics in ITER will rely on mirrors near the plasma and the deterioration of the reflectivity is a concern. The effect of temperature on the deposition efficiency of hydrocarbons under long-term operation conditions similar to ITER was investigated in the linear plasma generator Pilot-P

  14. Improvement of proton exchange membrane fuel cell electrical performance by optimization of operating parameters and electrodes preparation

    Energy Technology Data Exchange (ETDEWEB)

    Kadjo, A.J.-J.; Garnier, J.-P.; Martemianov, S. [Laboratoire d' Etudes Thermiques, UMR6608, ESIP-Universite de Poitiers, CNRS, Poitiers F-86022 (France); Brault, P.; Caillard, A. [Groupe de Recherche sur l' Energetique des Milieux Ionises, UMR6606 Universite d' Orleans, CNRS Polytech' Orleans BP6744, F-45067 Orleans Cedex 2 (France); Coutanceau, C. [Laboratoire de Catalyse en Chimie Organique, UMR6503 Universite de Poitiers, CNRS, Poitiers F-86022 (France)

    2007-10-25

    The effect of operating parameters (cell temperature, humidifiers temperature, gases flows and pressures) on the performance of a 25 cm{sup 2} surface area fuel cell is performed. After optimization, a homemade MEA fitted with electrodes prepared via the colloidal route leads to achieve reproducibly maximum power densities higher than 1.2 W cm{sup -2} with a total catalyst loading of 0.7 mg{sub Pt} cm{sup -2} (corresponding to 1.7kW g{sub Pt}{sup -1}). This electrical performance is higher to that obtained with a commercial MEA provided by fuel cell store (total platinum loading of 1.2 mg cm{sup -2} and power density close to 1 W cm{sup -2}, corresponding to 0.75kW g{sub Pt}{sup -1}). Based on this experience, two different homemade MEAs are tested under optimal operating conditions and compared to the commercial one. The final goal is to decrease significantly the platinum loading preserving at least equivalent PEMFC electrical performance. The method of catalyst deposition by plasma sputtering is used to further decrease the total catalyst loading down to 0.45 mg{sub Pt} cm{sup -2}. Very interesting performances (close to 0.7 W cm{sup -2}) were obtained with this low-platinum loading MEA (corresponding to 1.6kW g{sub Pt}{sup -1}). However, it was shown that the decrease of the platinum loading in the cathode from 0.35 to 0.1 mg cm{sup -2} affects the kinetics of oxygen reduction (exchange current density j{sub 0} and Tafel slope b) and the resistance of the cell R, and hence the cell electrical performance. (author)

  15. Operating conditions for the generation of stable anode spot plasma in front of a positively biased electrode

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yeong-Shin; Lee, Yuna; Dang, Jeong-Jeung [Department of Nuclear Engineering, Seoul National University, Seoul 151-744 (Korea, Republic of); Chung, Kyoung-Jae, E-mail: jkjlsh1@snu.ac.kr [Center for Advance Research in Fusion Reactor Engineering, Seoul National University, Seoul 151-744 (Korea, Republic of); Hwang, Y. S. [Department of Nuclear Engineering, Seoul National University, Seoul 151-744 (Korea, Republic of); Center for Advance Research in Fusion Reactor Engineering, Seoul National University, Seoul 151-744 (Korea, Republic of)

    2014-02-15

    Stability of an anode spot plasma, which is an additional high density plasma generated in front of a positively biased electrode immersed in ambient plasma, is a critical issue for its utilization to various types of ion sources. In this study, operating conditions for the generation of stable anode spot plasmas are experimentally investigated. Diagnostics of the bias current flowing into the positively biased electrode and the properties of ambient plasma reveal that unstable nature of the anode spot is deeply associated with the reduction of double layer potential between the anode spot plasma and the ambient plasma. It is found that stability of the anode spot plasma can be improved with increasing the ionization rate in ambient plasma so as to compensate the loss of electrons across the double layer or with enlarging the area of the biased electrode to prevent electron accumulation inside the anode spot. The results obtained from the present study give the guideline for operating conditions of anode spot plasmas as an ion source with high brightness.

  16. Feedback control of plasma density and heating power for steady state operation in LHD

    Energy Technology Data Exchange (ETDEWEB)

    Kamio, Shuji, E-mail: kamio@nifs.ac.jp; Kasahara, Hiroshi; Seki, Tetsuo; Saito, Kenji; Seki, Ryosuke; Nomura, Goro; Mutoh, Takashi

    2015-12-15

    Highlights: • We upgraded a control system for steady state operation in LHD. • This system contains gas fueling system and ICRF power control system. • Automatic power boost system is also attached for stable operation. • As a result, we achieved the long pulse up to 48 min in the electron density of more than 1 × 10{sup 19} m{sup −3}. - Abstract: For steady state operation, the feedback control of plasma density and heating power system was developed in the Large Helical Device (LHD). In order to achieve a record of the long pulse discharge, stable plasma density and heating power are needed. This system contains the radio frequency (RF) heating power control, interlocks, gas fueling, automatic RF phase control, ion cyclotron range of frequency (ICRF) antenna position control, and graphical user interface (GUI). Using the density control system, the electron density was controlled to the target density and using the RF heating power control system, the RF power injection could be stable. As a result of using this system, we achieved the long pulse up to 48 min in the electron density of more than 1 × 10{sup 19} m{sup −3}. Further, the ICRF hardware experienced no critical accidents during the 17th LHD experiment campaign in 2013.

  17. Parameter identification of fractional order linear system based on Haar wavelet operational matrix.

    Science.gov (United States)

    Li, Yuanlu; Meng, Xiao; Zheng, Bochao; Ding, Yaqing

    2015-11-01

    Fractional order systems can be more adequate for the description of dynamical systems than integer order models, however, how to obtain fractional order models are still actively exploring. In this paper, an identification method for fractional order linear system was proposed. This is a method based on input-output data in time domain. The input and output signals are represented by Haar wavelet, and then fractional order systems described by fractional order differential equations are transformed into fractional order integral equations. Taking use of the Haar wavelet operational matrix of the fractional order integration, the fractional order linear system can easily be converted into a system of algebraic equation. Finally, the parameters of the fractional order system are determined by minimizing the errors between the output of the real system and that of the identified system. Numerical simulations, involving integral and fractional order systems, confirm the efficiency of the above methodology.

  18. Key Parameters for Operator Diagnosis of BWR Plant Condition during a Severe Accident

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, Dwight A [ORNL; Poore III, Willis P [ORNL

    2015-01-01

    The objective of this research is to examine the key information needed from nuclear power plant instrumentation to guide severe accident management and mitigation for boiling water reactor (BWR) designs (specifically, a BWR/4-Mark I), estimate environmental conditions that the instrumentation will experience during a severe accident, and identify potential gaps in existing instrumentation that may require further research and development. This report notes the key parameters that instrumentation needs to measure to help operators respond to severe accidents. A follow-up report will assess severe accident environmental conditions as estimated by severe accident simulation model analysis for a specific US BWR/4-Mark I plant for those instrumentation systems considered most important for accident management purposes.

  19. Communication: Effects of thermionic-gun parameters on operating modes in ultrafast electron microscopy

    Directory of Open Access Journals (Sweden)

    Erik Kieft

    2015-09-01

    Full Text Available Ultrafast electron microscopes with thermionic guns and LaB6 sources can be operated in both the nanosecond, single-shot and femtosecond, single-electron modes. This has been demonstrated with conventional Wehnelt electrodes and absent any applied bias. Here, by conducting simulations using the General Particle Tracer code, we define the electron-gun parameter space within which various modes may be optimized. The properties of interest include electron collection efficiency, temporal and energy spreads, and effects of laser-pulse duration incident on the LaB6 source. We find that collection efficiencies can reach 100% for all modes, despite there being no bias applied to the electrode.

  20. Influence of operation parameters on flash smelting furnace based on CFD

    Institute of Scientific and Technical Information of China (English)

    Xinfeng Li; Shiheng Peng; Xiangli Han; Chi Mei; Tianyuan Xiao

    2004-01-01

    The influence of three important operation parameters in Jinlong flash smelting furnace, including the distributing blast speed, the oxygen enrichment rate of process air and the ratio of central oxygen to overall oxygen (Oc/Oo), has been investigated using a virtual simulation system on copper flash smelting furnace. The core of this virtual simulation system is a numerical simulation of CFD (computational fluid dynamics), and this system incorporates coupling momentum transport, heat transport, mass transport,reaction kinetics between gas and particles and chemical reactions between gas and gas. A set of numerical predicted data were obtained. The CFD simulation shows that there is a sensitive zone of the distributing blast speed, and the dust content ascends when the speed exceeds 180 m-s-1. Increasing the oxygen concentration of processing air benefits the efficient production of the flash smelting furnace.

  1. Anthropogenic seismicity rates and operational parameters at the Salton Sea Geothermal Field.

    Science.gov (United States)

    Brodsky, Emily E; Lajoie, Lia J

    2013-08-01

    Geothermal power is a growing energy source; however, efforts to increase production are tempered by concern over induced earthquakes. Although increased seismicity commonly accompanies geothermal production, induced earthquake rate cannot currently be forecast on the basis of fluid injection volumes or any other operational parameters. We show that at the Salton Sea Geothermal Field, the total volume of fluid extracted or injected tracks the long-term evolution of seismicity. After correcting for the aftershock rate, the net fluid volume (extracted-injected) provides the best correlation with seismicity in recent years. We model the background earthquake rate with a linear combination of injection and net production rates that allows us to track the secular development of the field as the number of earthquakes per fluid volume injected decreases over time.

  2. Membrane reactor for water detritiation: a parametric study on operating parameters

    Energy Technology Data Exchange (ETDEWEB)

    Mascarade, J.; Liger, K.; Troulay, M.; Perrais, C. [CEA, DEN, DTN/STPA/LIPC, Centre de Cadarache, Saint-Paul-lez-Durance (France); Joulia, X.; Meyer, X.M. [Universite de Toulouse, INPT, UPS, Laboratoire de Genie Chimique, Toulouse (France); CNRS, Laboratoire de Genie Chimique, Toulouse (France)

    2015-03-15

    This paper presents the results of a parametric study done on a single stage finger-type packed-bed membrane reactor (PBMR) used for heavy water vapor de-deuteration. Parametric studies have been done on 3 operating parameters which are: the membrane temperature, the total feed flow rate and the feed composition through D{sub 2}O content variations. Thanks to mass spectrometer analysis of streams leaving the PBMR, speciation of deuterated species was achieved. Measurement of the amounts of each molecular component allowed the calculation of reaction quotient at the packed-bed outlet. While temperature variation mainly influences permeation efficiency, feed flow rate perturbation reveals dependence of conversion and permeation properties to contact time between catalyst and reacting mixture. The study shows that isotopic exchange reactions occurring on the catalyst particles surface are not thermodynamically balanced. Moreover, the variation of the heavy water content in the feed exhibits competition between permeation and conversion kinetics.

  3. Analysis of Operational Parameters Affecting the Sulfur Content in Hot Metal of the COREX Process

    Science.gov (United States)

    Wu, Shengli; Wang, Laixin; Kou, Mingyin; Wang, Yujue; Zhang, Jiacong

    2017-02-01

    The COREX process, which has obvious advantages in environment protection, still has some disadvantages. It has a higher sulfur content in hot metal (HM) than the blast furnace has. In the present work, the distribution and transfer of sulfur in the COREX have been analyzed and several operational parameters related to the sulfur content in HM ([pct S]) have been obtained. Based on this, the effects of the coal rate, slag ratio, temperature of HM, melting rate, binary basicity ( R 2), the ratio of MgO/Al2O3, utilization of reducing gas, top gas consumption per ton burden solid, metallization rate, oxidation degree of reducing gas, and coal and DRI distribution index on the sulfur content in HM are investigated. What's more, a linear model has been developed and subsequently used for predicting and controlling the S content in HM of the COREX process.

  4. Plasmas, Dielectrics and the Ultrafast: First Science and Operational Experience at FACET

    Energy Technology Data Exchange (ETDEWEB)

    Clarke, C.I.; Adli, E.; Corde, S.; Decker, F.J.; England, R.J.; Erickson, R.; Fisher, A.; Gessner, S.; Hast, C.; Hogan, M.J.; Li, S.Z.; Lipkowitz, N.; Litos, M.; Nosochkov, Y.; Seeman, J.; Sheppard, J.C.; Tudosa, I.; White, G.; Wienands, U.; Woodley, M.; Wu, Z.; /SLAC /UCLA

    2012-09-14

    FACET (Facility for Advanced Accelerator and Experimental Tests) is an accelerator R&D test facility that has been recently constructed at SLAC National Accelerator Laboratory. The facility provides 20 GeV, 3 nC electron beams, short (20 {micro}m) bunches and small (20 {micro}m wide) spot sizes, producing uniquely high power beams. FACET supports studies from many fields but in particular those of Plasma Wakefield Acceleration and Dielectric Wakefield Acceleration. FACET is also a source of THz radiation for material studies. We present the FACET design, initial operating experience and first science from the facility.

  5. Operational and theoretical temperature considerations in a Penning surface plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Faircloth, D. C., E-mail: dan.faircloth@stfc.ac.uk; Lawrie, S. R. [ISIS Neutron and Muon Facility, STFC Rutherford Appleton Laboratory, Harwell Oxford, OX11 0QX (United Kingdom); Pereira Da Costa, H. [CERN, Geneva (Switzerland); Dudnikov, V. [Muons Inc. United States of America (United States)

    2015-04-08

    A fully detailed 3D thermal model of the ISIS Penning surface plasma source is developed in ANSYS. The proportion of discharge power applied to the anode and cathode is varied until the simulation matches the operational temperature observations. The range of possible thermal contact resistances are modelled, which gives an estimation that between 67% and 85% of the discharge power goes to the cathode. Transient models show the electrode surface temperature rise during the discharge pulse for a range of duty cycles. The implications of these measurements are discussed and a mechanism for governing cesium coverage proposed. The requirements for the design of a high current long pulse source are stated.

  6. The influence of operational parameters and feed preparation in a convective batch ribbon powder mixer

    Directory of Open Access Journals (Sweden)

    Yeow ST

    2011-11-01

    Full Text Available Sin Tung Yeow, Asnawi Shahar, Norashikin Abdul Aziz, Mohd Shamsul Anuar, Yus Aniza Yusof, Farah Saleena TaipDepartment of Process and Food Engineering, Faculty of Engineering, Universiti Putra Malaysia, Selangor, MalaysiaPurpose: To investigate the effect of feed preparation characteristics and operational parameters on mixing homogeneity in a convective batch ribbon mixer.Methods: Lactose 100M, lactose 200M, ascorbic acid, and zinc oxide powders were used for the mixing study. Operational parameters studied were rotational speed and mixing time. The feed preparations studied were the use of preblending and the particle size of the feed materials. The blends of ascorbic acid, zinc oxide, and lactose were prepared with preblending and without preblending, prior to mixing at different blender rotation speeds and mixing times. Chemical tests were performed to measure the homogeneity of the ascorbic acid in the model mixture.Results: With preblending, a mixture with lactose 200M achieved the required homogeneity in a shorter period of time at a lower rotational speed.Conclusion: The results indicated that the homogeneity of the mixtures was influenced by the blender rotation speed and mixing time. Better mixing can be obtained with higher rotation speeds and longer mixing time. It was also observed that preblending and smaller feed particle size achieved the required homogeneity in a shorter period of time at a lower rotational speed. These results illustrate that using binders with a smaller particle size and a preblending technique improves the mixing process in a convective batch ribbon powder mixer. However, prolonged periods of high-speed mixing will lead to mixture segregation.Keywords: powder blending, ascorbic acid, rotational speed, particle size, preblending

  7. Effect of magnetic configuration on plasma parameters in the H-1 heliac

    Energy Technology Data Exchange (ETDEWEB)

    Blackwell, B.D.; Pretty, D.G.; Harris, J.H.; Howard, J.; Shats, M.G.; Collis, S.M.; Gardner, H.J.; Michael, C.A.; Punzmann, H. [Plasma Research Laboratory, Research School of Physical Sciences and Engineering Australian National University, ACT (Australia)

    2003-07-01

    The H-1 heliac is a current-free stellarator with a helical magnetic axis which twists around the machine axis (a circular ring conductor, radius 1m) three times in one toroidal rotation. It us a ''flexible'' heliac composed almost entirely of circular coils with the exception of the helical control winding, which also wraps around the ring conductor, in phase with the magnetic axis of the plasma, but with a smaller swing radius (95 mm c.f. {proportional_to} 230 mm). In addition to indicating particle confinement times, this phenomenon may be sensitive to plasma generation efficiency. There may be some interaction between configuration and impurity generation, as plasma boundaries and strike points are varied. Various plasma conditions and formation techniques are compared. (orig.)

  8. Influence of instrumental parameters on the kinetic energy of ions and plasma temperature for a hexapole collision/reaction-cell-based inductively coupled plasma quadrupole mass spectrometer.

    Science.gov (United States)

    Favre, Georges; Brennetot, René; Chartier, Frédéric; Tortajada, Jeanine

    2009-02-01

    Inductively coupled plasma mass spectrometry (ICP-MS) is widely used in inorganic analytical chemistry for element and/or isotope ratio measurements. The presence of interferences, which is one of the main limitations of this method, has been addressed in recent years with the introduction of collision/reaction cell devices on ICP-MS apparatus. The study of ion-molecule reactions in the gas phase then became of great importance for the development of new analytical strategies. Knowing the kinetic energy and the electronic states of the ions prior to their entrance into the cell, i.e., just before they react, thereby constitutes crucial information for the interpretation of the observed reactivities. Such studies on an ICP-MS commonly used for routine analyses require the determination of the influence of different instrumental parameters on the energy of the ions and on the plasma temperature from where ions are sampled. The kinetic energy of ions prior to their entrance into the cell has been connected to the voltage applied to the hexapole according to a linear relationship determined from measurements of ion energy losses due to collisions with neutral gas molecules. The effects of the plasma forward power, sampling depth, and the addition of a torch shield to the ICP source were then examined. A decrease of the plasma potential due to the torch shielding, already mentioned in the literature, has been quantified in this study at about 3 V.

  9. An improved model to analyze Langmuir probe assisted photo-detachment signal for measuring electronegative plasma parameters

    Science.gov (United States)

    Sirse, Nishant; Oudini, Noureddine; Bendib, Abderrezeg; Ellingboe, Albert R.

    2016-09-01

    A diagnostic technique for measuring negative ion parameters based on Langmuir probe assisted laser photo-detachment relies on a theoretical model which relates the rise in the electron saturation current to electronegativity in the plasma. The existing model depend on various assumptions and neglect electrostatic potential barrier formed between the laser column (electropositive column) and the surrounding electronegative plasma in order to prevent the outward flow of electrons from the electropositive plasma column. These assumptions leads to erroneous estimation of the plasma electronegativity. In the present work, we present an analytical model to analyze Langmuir probe assisted photo-detachment signal in order to improve the accuracy of measured electronegativity and extended this technique for measuring electron temperature and charged species density. The analytical model is validated using both experiments and particle-in-cell simulation. The results shows improved accuracy in the measured parameters when compared to existing model. This work was supported by the Korea Institute for the Advancement of Technology and Ministry of Knowledge Economy (L-2010-1438-000), Republic of Korea, Enterprise Ireland and the European Regional Development Fund (ERDF) under NSRF 2007-2013.

  10. Kinetic parameters and intraindividual fluctuations of ochratoxin A plasma levels in humans

    Energy Technology Data Exchange (ETDEWEB)

    Studer-Rohr, I. [Inst. of Toxicology, Swiss Federal Inst. of Tech. and Univ. of Zurich, Schwerzenbach (Switzerland); Dept. of Food Science, Swiss Federal Inst. of Tech., Zurich (Switzerland); Schlatter, J. [Toxicology Section, Div. of Food Science, Swiss Federal Office of Public Health, Zurich (Switzerland); Dietrich, D.R. [Dept. of Environmental Toxicology, Univ. of Konstanz, Konstanz (Germany); Inst. of Toxicology, Swiss Federal Inst. of Tech. and Univ. of Zurich, Schwerzenbach (Switzerland)

    2000-11-01

    The mycotoxin ochratoxin A (OTA) is a rodent carcinogen produced by species of the ubiquitous fungal genera Aspergillus and Penicillium. OTA is found in a variety of food items and as a consequence is also found in human plasma (average concentrations found in this study: 0.1-1 ng OTA/ml plasma). To improve the scientific basis for cancer risk assessment the toxicokinetic profile of OTA was studied in one human volunteer following ingestion of 395 ng {sup 3}H-labeled OTA (3.8 {mu}Ci). A two-compartment open model consisting of a central compartment was found to best describe the in vivo data. This two-compartment model consisted of a fast elimination and distribution phase (T{sub 1/2} about 20 h) followed by a slow elimination phase (renal clearance about 0.11 ml/min.) and a calculated plasma half-life of 35.55 days. This half-life was approximately eight times longer than that determined previously in rats. In addition, the intraindividual fluctuation of OTA plasma levels was investigated in eight individuals over a period of 2 months. The concentrations determined ranged between 0.2 and 0.9 ng OTA/ml plasma. The plasma levels in some individuals remained nearly constant over time, while others varied considerably (e.g. increase of 0.4 ng/ml within 3 days, decrease of 0.3 ng/ml within 5 days) during the observation period. This intraindividual fluctuation in OTA plasma levels, which may represent differences in OTA exposure and/or metabolism, as well as the large difference in plasma half-life in humans compared to rats must be taken into consideration when the results of rat cancer study data are extrapolated to humans for risk assessment purposes. (orig.)

  11. DETERMINATION OF MAIN OUTPUT PARAMETERS FOR HYDROFICATED CONSTRUCTION AND ROAD-BUILDING MACHINES AT OPERATIONAL STAGE OF THEIR LIFE CYCLE

    Directory of Open Access Journals (Sweden)

    A. N. Maximenko

    2014-01-01

    Full Text Available Usage efficiency of mechanical engineering products is determined by level of their operating capability. Expenses connected with provision of operating capability for the whole operational period exceed initial cost of the products by 6-10-fold. Moreover , while being used the expenses have a tendency to increase with reduction of output parameters that ensure product application efficiency for its intended purpose. It is necessary to take into account these changes at manufacturing stages of mechanical engineering products. Maximum efficiency can be obtained at the operational stage of the product life cycle only as a result of complex and interrelated measures during designing, manufacturing and usage of the specific product for its intended purpose with due account of its output parameter dynamics. While using the product an analysis of its output parameter dynamics will make it possible to determine maximum value of the operating capability, operational expenses and best practices for obtaining maximum profit per operating time unit.Taking hydroficated excavators of the 5th grade as an example the paper presents dynamics of main output parameters at the operational stage of their life cycle; reveals the main factor influencing on intensity of hydroficated machine operating capability reduction; substantiates an expediency of taking into account output parameter dynamics while evaluating efficiency of its usage; proposes a methodology for determination of or a pay-off time period for recoupment of expenses pertaining to machine procurement and optimum time period for operational stage, its life cycle that corresponds to obtaining maximum profit.Nowadays constant values of main output parameters (operating capability, self cost of machine-hour corresponding to the beginning of operation are to be taken into account while determining expediency of machine creation. Practically they significantly change in the process of machine operation this

  12. Evaluation of passive autocatalytic recombiners operation efficiency by means of the lumped parameter approach*

    Directory of Open Access Journals (Sweden)

    Bury Tomasz

    2015-06-01

    Full Text Available The problem of hydrogen behavior in containment buildings of nuclear reactors belongs to thermal-hydraulic area. Taking into account the size of systems under consideration and, first of all, safety issues, such type of analyses cannot be done by means of full-scale experiments. Therefore, mathematical modeling and numerical simulations are widely used for these purposes. A lumped parameter approach based code HEPCAL has been elaborated in the Institute of Thermal Technology of the Silesian University of Technology for simulations of pressurized water reactor containment transient response. The VVER-440/213 and European pressurised water reactor (EPR reactors containments are the subjects of analysis within the framework of this paper. Simulations have been realized for the loss-of-coolant accident scenarios with emergency core cooling system failure. These scenarios include core overheating and hydrogen generation. Passive autocatalytic recombiners installed for removal of hydrogen has been taken into account. The operational efficiency of the hydrogen removal system has been evaluated by comparing with an actual hydrogen concentration and flammability limit. This limit has been determined for the three-component mixture of air, steam and hydrogen. Some problems related to the lumped parameter approach application have been also identified.

  13. An automated approach for tone mapping operator parameter adjustment in security applications

    Science.gov (United States)

    Krasula, LukáÅ.¡; Narwaria, Manish; Le Callet, Patrick

    2014-05-01

    High Dynamic Range (HDR) imaging has been gaining popularity in recent years. Different from the traditional low dynamic range (LDR), HDR content tends to be visually more appealing and realistic as it can represent the dynamic range of the visual stimuli present in the real world. As a result, more scene details can be faithfully reproduced. As a direct consequence, the visual quality tends to improve. HDR can be also directly exploited for new applications such as video surveillance and other security tasks. Since more scene details are available in HDR, it can help in identifying/tracking visual information which otherwise might be difficult with typical LDR content due to factors such as lack/excess of illumination, extreme contrast in the scene, etc. On the other hand, with HDR, there might be issues related to increased privacy intrusion. To display the HDR content on the regular screen, tone-mapping operators (TMO) are used. In this paper, we present the universal method for TMO parameters tuning, in order to maintain as many details as possible, which is desirable in security applications. The method's performance is verified on several TMOs by comparing the outcomes from tone-mapping with default and optimized parameters. The results suggest that the proposed approach preserves more information which could be of advantage for security surveillance but, on the other hand, makes us consider possible increase in privacy intrusion.

  14. Effects of Laser Operating Parameters on Piezoelectric Substrates Micromachining with Picosecond Laser

    Directory of Open Access Journals (Sweden)

    Lamia EL Fissi

    2014-12-01

    Full Text Available Ten picoseconds (200 kHz ultrafast laser micro-structuring of piezoelectric substrates including AT-cut quartz, Lithium Niobate and Lithium Tantalate have been studied for the purpose of piezoelectric devices application ranging from surface acoustic wave devices, e.g., bandpass filters, to photonic devices such as optical waveguides and holograms. The study examines the impact of changing several laser parameters on the resulting microstructural shapes and morphology. The micromachining rate has been observed to be strongly dependent on the operating parameters, such as the pulse fluence, the scan speed and the scan number. The results specifically indicate that ablation at low fluence and low speed scan tends to form a U-shaped cross-section, while a V-shaped profile can be obtained by using a high fluence and a high scan speed. The evolution of surface morphology revealed that laser pulses overlap in a range around 93% for both Lithium Niobate (LiNbO3 and Lithium Tantalate (LiTaO3 and 98% for AT-cut quartz can help to achieve optimal residual surface roughness.

  15. Sensitivity analysis in oxidation ditch modelling: the effect of variations in stoichiometric, kinetic and operating parameters on the performance indices

    NARCIS (Netherlands)

    Abusam, A.A.A.; Keesman, K.J.; Straten, van G.; Spanjers, H.; Meinema, K.

    2001-01-01

    This paper demonstrates the application of the factorial sensitivity analysis methodology in studying the influence of variations in stoichiometric, kinetic and operating parameters on the performance indices of an oxidation ditch simulation model (benchmark). Factorial sensitivity analysis investig

  16. Connecting Anthropogenic Seismicity Rates To Operational Parameters At The Salton Sea Geothermal Field, Southern California (Invited)

    Science.gov (United States)

    Brodsky, E. E.; Lajoie, L. J.

    2013-12-01

    Geothermal power is generated at several major volcanic fields in California. As efforts to monitor seismicity increase, methods to understand the anthropogenic component need to improve. Ideally, induced earthquake rate should be forecast based on publicly-reported volumes of fluid injection or other operational parameters. At the flash facilities in the Salton Sea Geothermal Field, the total volume of fluid extracted or injected tracks the long-term evolution of seismicity. However, for recent years net fluid volume (extracted-injected) is better correlated with seismicity. After correcting for the variable aftershock rate using an Epidemic-Type Aftershock Sequence model (ETAS), we fit the background earthquake rate with a linear combination of injection and net production rate that allows us to track the secular evolution of the field. The number of earthquakes per fluid volume injected decreases gradually over time. In the Salton Sea Geothermal Field, the new analysis of induced seismicity provides a template for future evaluation of hazard directly based on measureable, controllable operational quantities. The interactions of these anthropogenic events with the larger-scale tectonic and volcanic systems remains to be investigated. Results of the linear model of seismicity based on a combination of net production and injection. (a) Example of observed seismicity rate and model prediction using the reported fluid data and the best-fit linear model. (b) Number of earthquakes triggered per net volume of fluid extracted or total fluid injection.

  17. Influence of operational parameters on electro-Fenton degradation of organic pollutants from soil.

    Science.gov (United States)

    Rosales, E; Pazos, M; Longo, M A; Sanroman, M A

    2009-09-01

    The combination of the Fenton's reagent with electrochemistry (the electro-Fenton process) represents an efficient method for wastewater treatment. This study describes the use of this process to clean soil or clay contaminated by organic compounds. Model soil of kaolinite clay polluted with the dye Lissamine Green B (LGB) was used to evaluate the capability of the electro-Fenton process. The effects of operating parameters such as electrode material and dye concentration were investigated. Operating in an electrochemical cell under optimized conditions while using electrodes of graphite, a constant potential difference of 5 V, pH 3, 0.2 mM FeSO(4). 7H(2)O, and electrolyte 0.1 M Na(2)SO(4), around 80% of the LGB dye on kaolinite clay was decolorized after 3 hours with an electric power consumption around 0.15 W h g(-1). Furthermore, the efficiency of this process for the remediation of a real soil polluted with phenanthrene, a typical polycyclic aromatic hydrocarbon, has been demonstrated.

  18. ANALYSIS OF OPERATING PARAMETERS AND INDICATORS OF A COMPRESSION IGNITION ENGINE FUELLED WITH LPG

    Directory of Open Access Journals (Sweden)

    Krzysztof GARBALA

    2016-12-01

    Full Text Available This article presents the possibilities for using alternative fuels to power vehicles equipped with compression ignition (CI engines (diesel. Systems for using such fuels have been discussed. Detailed analysis and research covered the LPG STAG autogas system, which is used to power dual-fuel engine units (LPG+diesel. A description of the operation of the autogas system and installation in a vehicle has been presented. The basic algorithms of the controller, which is an actuating element of the whole system, have been discussed. Protection systems of a serial production engine unit to guarantee its factorycontrolled durability standards have been presented. A long-distance test drive and examinations of the engine over 150,000 km in a Toyota Hilux have been performed. Operating parameters and performance indicators of the engine with STAG LPG+diesel fuelling have been verified. Directions and perspectives for the further development of such a system in diesel-powered cars have been also indicated.

  19. Influence of argon fraction on plasma parameters in H2-N2 mixture discharge with cathodic cage

    Science.gov (United States)

    Naeem, Muhammad; Zaka-ul-Islam, Mujahid; Khattak, Zahid Iqbal; Shafiq, Muhammad; Zakaullah, Muhammad

    2017-01-01

    Low-pressure H2-N2 mixture pulsed DC plasmas with a cathodic cage (active screen) are widely used for plasma nitriding applications. In this study, the low-pressure H2-N2 mixture plasma with a cathodic cage generated by 50 Hz pulsed DC source is investigated with triple Langmuir probe and optical emission spectroscopy. The electron temperature (TeLP T e LP ) and electron number density (ne) are measured using a triple Langmuir probe (TLP). The excitation temperature (TexcOES T e xc OES ) is calculated spectroscopically using Boltzmann plot method whereas nitrogen dissociation fraction is estimated using actinometry as well as the intensity ratio method (IN (746.83 nm)/IN2(337.1 nm)). The results show that the electron and excitation temperatures, electron density and nitrogen atomic species density [N] all increase with the argon admixture, however, the important molecular ionized species density [N2+ N 2 + ] significantly decreases beyond 30% addition. This study provides useful information about the influence of the argon addition on plasma parameters and active species generation. As a result it helps to optimize the plasma nitriding system as a function of argon admixture to avoid random trials in the processing.

  20. Effect of q-nonextensive parameter and saturation time on electron density steepening in electron-positron-ion plasmas

    Science.gov (United States)

    Hashemzadeh, M.

    2015-11-01

    The effect of q-nonextensive parameter and saturation time on the electron density steepening in electron-positron-ion plasmas is studied by particle in cell method. Phase space diagrams show that the size of the holes, and consequently, the number of trapped particles strongly depends on the q-parameter and saturation time. Furthermore, the mechanism of the instability and exchange of energy between electron-positron and electric field is explained by the profiles of the energy density. Moreover, it is found that the q-parameter, saturation time, and electron and positron velocities affect the nonlinear evolution of the electron density which leads to the steepening of its structure. The q-nonextensive parameter or degree of nonextensivity is the relation between temperature gradient and potential energy of the system. Therefore, the deviation of q-parameter from unity indicates the degree of inhomogeneity of temperature or deviation from equilibrium. Finally, using the kinetic theory, a generalized q-dispersion relation is presented for electron-positron-ion plasma systems. It is found that the simulation results in the linear regime are in good agreement with the growth rate results obtained by the kinetic theory.

  1. Enhancement of the life of refractories through the operational experience of plasma torch melter

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Young Pyo [Technology Institute, Korea Radioactive waste Agency (KORAD), Daejeon (Korea, Republic of); Choi, Jaang Young [Chungnam National University, Daejeon (Korea, Republic of)

    2016-06-15

    The properties of wastes for melting need to be considered to minimize the maintenance of refractory and to discharge the molten slags smoothly from a plasma torch melter. When the nonflammable wastes from nuclear facilities such as concrete debris, glass, sand, etc., are melted, they become acid slags with low basicity since the chemical composition has much more acid oxides than basic oxides. A molten slag does not have good characteristics of discharge and is mainly responsible for the refractory erosion due to its low liquidity. In case of a stationary plasma torch melter with a slant tapping port on the wall, a fixed amount of molten slags remains inside of tapping hole as well as the melter inside after tapping out. Nonmetallic slags keep the temperature higher than melting point of metal because metallic slags located on the bottom of melter by specific gravity difference are simultaneously melted when dual mode plasma torch operates in transferred mode. In order to minimize the refractory erosion, the compatible refractories are selected considering the temperature inside the melter and the melting behavior of slags whether to contact or noncontact with molten slags. An acidic refractory shall not be installed in adjacent to a basic refractory for the resistibility against corrosion.

  2. Direct imaging of the dynamics of a laser-plasma accelerator operating in the bubble-regime

    CERN Document Server

    Sävert, A; Schnell, M; Cole, J M; Nicolai, M; Reuter, M; Schwab, M B; Möller, M; Poder, K; Jäckel, O; Paulus, G G; Spielmann, C; Najmudin, Z; Kaluza, M C

    2014-01-01

    Laser-plasma accelerators operating in the bubble-regime generate quasi-monoenergetic multi-gigaelectronvolt electron beams with femtosecond duration and micrometre size. These beams are produced by accelerating in laser-driven plasma waves in only centimetre distances. Hence they have the potential to be compact alternatives to conventional accelerators. However, since the plasma wave moves at ultra-relativistic speed making detailed observation extremely difficult, most of our current understanding has been gained from high-performance computer simulations. Here, we present experimental results from an ultra-fast optical imaging technique visualising for the first time the non-linear dynamics in a laser-plasma accelerator. By freezing the relativistic motion of the plasma wave, our measurements reveal insight of unprecedented detail. In particular, we observe the plasma wave's non-linear formation, breaking, and transformation into a single bubble for the first time. Understanding the acceleration dynamics ...

  3. Note: Repetitive operation of the capacitor bank of the low-voltage miniature plasma focus at 50 Hz

    Science.gov (United States)

    Shukla, Rohit; Shyam, Anurag

    2013-10-01

    We have already reported the low-voltage operation of a plasma focus describing the operation of plasma focus at 4.2 kV which proposes possibility of making a repetitive system using compact driving source. Another recent article describes that the same capacitor-bank can drive the plasma focus for a measured ˜5 × 104 neutrons per shot at 5 kV and 59 kA current. In the present work, repetitive operation of the capacitor-bank of plasma focus is done and that too is being reported at a very high repetition rate of 50 Hz using very simple scheme of charging and triggering the bank. The bank is continuously discharged to burst duration of 20 s in this configuration admeasuring a thousand shots.

  4. Determining the microwave coupling and operational efficiencies of a microwave plasma assisted chemical vapor deposition reactor under high pressure diamond synthesis operating conditions.

    Science.gov (United States)

    Nad, Shreya; Gu, Yajun; Asmussen, Jes

    2015-07-01

    The microwave coupling efficiency of the 2.45 GHz, microwave plasma assisted diamond synthesis process is investigated by experimentally measuring the performance of a specific single mode excited, internally tuned microwave plasma reactor. Plasma reactor coupling efficiencies (η) > 90% are achieved over the entire 100-260 Torr pressure range and 1.5-2.4 kW input power diamond synthesis regime. When operating at a specific experimental operating condition, small additional internal tuning adjustments can be made to achieve η > 98%. When the plasma reactor has low empty cavity losses, i.e., the empty cavity quality factor is >1500, then overall microwave discharge coupling efficiencies (η(coup)) of >94% can be achieved. A large, safe, and efficient experimental operating regime is identified. Both substrate hot spots and the formation of microwave plasmoids are eliminated when operating within this regime. This investigation suggests that both the reactor design and the reactor process operation must be considered when attempting to lower diamond synthesis electrical energy costs while still enabling a very versatile and flexible operation performance.

  5. [Hardware-software system for monitoring parameters and characteristics of X-ray computer tomographs under operation conditions].

    Science.gov (United States)

    Blinov, N N; Zelikman, M I; Kruchinin, S A

    2007-01-01

    The results of testing of hardware and software for monitoring parameters (mean number of CT units, noise, field uniformity, high-contrast spatial resolution, layer width, dose) and characteristics (modulation transfer function) of X-ray computer tomographs are presented. The developed hardware and software are used to monitor the stability of X-ray computer tomograph parameters under operation conditions.

  6. Instability Parameters of Optical Oscillation Frequency in Plasma Central Discharge and Periphery Region

    Institute of Scientific and Technical Information of China (English)

    ZHOU Zhu-Wen; M.A.LIEBERMAN; Sungjin KIM

    2006-01-01

    @@ We have observed relaxation oscillations in a capacitive discharge in Ar gas, connected to a peripheral ground chamber. The plasma oscillations observed from time-varying optical emission from the main discharge chamber show, for example, a high frequency (75.37kHz) relaxation oscillation, at 100mTorr and 8 W absorbed power,and a low frequency (2.72 Hz) relaxation oscillation, 100mTorr and 325 W absorbed power. Time-varying optical emission intensity and plasma density are also detected with a Langmuir probe. The theoretical result agrees well with experiments.

  7. Characterization of Nuclease Activity in Human Seminal Plasma and its Relationship to Semen Parameters, Sperm DNA Fragmentation and Male Infertility.

    Science.gov (United States)

    Fernandez-Encinas, Alba; García-Peiró, Agustí; Ribas-Maynou, Jordi; Abad, Carlos; Amengual, María José; Navarro, Joaquima; Benet, Jordi

    2016-01-01

    Some studies have shown that complementary biomarkers are needed in semen analysis to provide a more accurate diagnosis for couples with infertility problems. To our knowledge no study has been done to determine the relationships among nuclease activity in seminal plasma, semen parameters, sperm DNA fragmentation and male infertility. A total of 94 semen samples were collected according to WHO 2010 semen analysis parameters. Samples were analyzed using the single radial enzyme diffusion method for nuclease activity in seminal plasma, and alkaline and neutral Comet assay for sperm DNA fragmentation. Samples were obtained from 11 fertile donors with proven fertility, 17 patients with normozoospermia in an infertile couple, and 16 patients with asthenozoospermia, 19 with teratozoospermia, 21 with asthenoteratozoospermia and 10 with azoospermia. Nuclease activity analyzed in seminal plasma was higher in patients than in controls. It correlated with sperm motility and morphology, and sperm DNA fragmentation measured by the alkaline Comet assay. No correlation with sperm DNA fragmentation was measured by the neutral Comet assay. ROC curves to determine male infertility revealed 0.658 sensitivity, 0.727 specificity and 0.705 cm(2) AUC for the single radial enzyme diffusion method, 0.918, 1 and 0.994 cm(2) for the alkaline Comet assay, and 0.917, 0.250 and 0.373 cm(2), respectively, for the neutral Comet assay. Nuclease activity in seminal plasma corrected by sperm count is a good variable to predict male infertility. Results indicate that it could be a useful complementary parameter for male infertility diagnosis. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  8. Invited article: physical and chemical analyses of impregnated cathodes operated in a plasma environment.

    Science.gov (United States)

    Sengupta, Anita; Kulleck, James; Hill, Norm; Ohlinger, Wayne

    2008-11-01

    Destructive analyses of impregnated-cathode assemblies from an ion thruster life test were performed to characterize erosion and degradation after 30,472 h of operation. Post-test inspection of each cathode included examination of the emitter (insert), orifice plate, cathode tube, heater, anode assembly, insulator, and propellant isolator. The discharge-cathode assembly experienced significant erosion due to ion sputtering from the discharge plasma. The keeper electrode plate was removed and the heater and orifice plate were heavily eroded at the conclusion of the test. Had the test continued, these processes would likely have led to cathode failure. The discharge cathode insert experienced significant tungsten transport and temperature dependent barium oxide depletion within the matrix. Using barium depletion semiempirical relations developed by Palluel and Shroff, it is estimated that 25,000 h of operation remained in the discharge insert at the conclusion of the test. In contrast, the neutralizer insert exhibited significantly less tungsten transport and barium oxide depletion consistent with its lower current operation. The neutralizer was estimated to have 140,000 h of insert life remaining at the conclusion of the test. Neither insert had evidence of tungstate or oxide layer formation, previously known to have impeded cathode ignition and operation in similar long duration hollow-cathode tests. The neutralizer cathode was in excellent condition at the conclusion of the test with the exception of keeper tube erosion from direct plume-ion impingement, a previously underappreciated life-limiting mechanism. The most critical finding from the test was a power dependent deposition process within the neutralizer-cathode orifice. The process manifested at low-power operation and led to the production of energetic ions in the neutralizer plume, a potential life-limiting process for the neutralizer. Subsequent return of the engine and neutralizer operation to full

  9. Assembly, start and operation of an activated sludge reactor for the industrial effluents treatment: physico chemical and biological parameters

    Directory of Open Access Journals (Sweden)

    Márcia Regina Assalin

    2008-05-01

    Full Text Available Although of the immense available bibliography regarding the activated sludge process, little it is found in relation to the basic procedure to be adopted to implant, to activate and to monitor a reactor of activated sludge in laboratory scales. This article describes the assembly, departure and operation of an activated sludge system, operating in continuous process, at a laboratory scale, to study effluents treatments, using as example, Kraft E1 pulp mill effluent. Factors as biodegradability of the effluent to be treated, stationary state of the reactor, conventional operation parameters as physical chemistry and biological parameters are presented.

  10. Removal of Reactive Red 141 Dye from Synthetic Wastewater by Electrocoagulation Process: Investigation of Operational Parameters

    Directory of Open Access Journals (Sweden)

    Elham Rahmanpour Salmani

    2016-01-01

    Full Text Available Release of textile industries waste especially their dying effluent impose a serious pollution on the environment. Reactive dyes are one of the most used dyes which are recalcitrant to conventional treatment processes. In the performed project, the effectiveness of electrocoagulation process was studied on decolorization. RR141 was selected as model dye and treatment process was performed in a simple batch of electrocoagulation (EC cell using iron electrodes. Central Composite Design (CCD was used to plan study runs. Experiments were done under 5 levels of various operational parameters at bench scale. Initial concentration of dye was varied among 50 and 500ppm, pH ranging from 4-12; retention time was ranged between 3-30 minutes, 1-3cm was selected as the distance between electrodes, and current intensity studied under the range of 5-30 mA/cm2. EC treatment process of dyestuff wastewater was satisfactory at high levels of current density, pH, and retention time. While increasing the initial dye concentration and electrodes gap had a negative effect on decolorization performance. Determined optimal conditions to treat 200ml of sample were including pH: 9.68, electrode gap: 1.58cm, dye concentration: 180ppm, retention time: 10.82 minutes, and current intensity: 22.76mA/cm2. Successful removal of the model dye about 99.88% was recorded in the mentioned values of variables. Simple design and operation of the experiments can be an interesting option for implementation and applying of inexpensive electrocoagulation treatment process which was successful to reach nearly a complete decolorization.

  11. Developing safer systems in a NPP environment using the operator`s comfort parameters and virtual reality

    Energy Technology Data Exchange (ETDEWEB)

    Brown-VanHoozer, S.A.

    1995-07-01

    The contents of this paper is based on two studies involving the design of visual displays from the operator`s point of view, and the utilization of virtual reality for operations, training and maintenance repairs. The studies involve a methodology known as Neuro-Linguistic Programming (NLP), and its use in strengthening design choices from the user`s perspective model of the environment. The contents of this paper focuses on the results which may be implemented in nuclear power plants for the purpose of providing systems which are less inherently error prone.

  12. Surface temperature: A key parameter to control the propanethiol plasma polymer chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Thiry, Damien, E-mail: damien.thiry@umons.ac.be; Aparicio, Francisco J. [Chimie des Interactions Plasma Surface (ChIPS), CIRMAP, Université de Mons, 23 Place du Parc, B-7000 Mons (Belgium); Laha, Priya; Terryn, Herman [Research Group Electrochemical and Surface Engineering (SURF), Department of Materials and Chemistry (MACH), Pleinlaan 2, 1050 Brussel (Belgium); Snyders, Rony [Chimie des Interactions Plasma Surface (ChIPS), CIRMAP, Université de Mons, 23 Place du Parc, B-7000 Mons, Belgium and Materia Nova Research Center, Parc Initialis, B-7000 Mons (Belgium)

    2014-09-01

    In this work, the influence of the substrate temperature (T{sub s}) on the chemical composition of propanethiol plasma polymers was investigated for a given set of plasma conditions. In a first study, a decrease in the atomic sulfur content (at. %S) with the deposition time (t{sub d}) was observed. This behavior is explained by the heating of the growing film during deposition process, limiting the incorporation of stable sulfur-based molecules produced in the plasma. Experiments carried out by controlling the substrate temperature support this hypothesis. On the other hand, an empirical law relating the T{sub s} and the at. %S was established. This allows for the formation of gradient layer presenting a heterogeneous chemical composition along the thickness, as determined by depth profile analysis combining X-ray photoelectron spectroscopy and C{sub 60} ion gun sputtering. The experimental data fit with the one predicted from our empiric description. The whole set of our results provide new insights in the relationship between the substrate temperature and the sulfur content in sulfur-based plasma polymers, essential for future developments.

  13. The effect of plasma fluctuations on parallel transport parameters in the SOL

    DEFF Research Database (Denmark)

    Havlíčková, E.; Fundamenski, W.; Naulin, Volker

    2011-01-01

    in the scrape-off layer (SOL) taking into account these fluctuations is presented. Plasma transport in the SOL along the magnetic field between two targets is calculated by a one-dimensional fluid code in order to estimate the response to transient conditions along the SOL and the attention is given...

  14. Evolution of the plasma parameters in the expanding laser ablation plume of silver

    DEFF Research Database (Denmark)

    Christensen, Bo Toftmann; Schou, Jørgen; Hansen, T.N.;

    2002-01-01

    The angular and radial variation of the ion density and electron temperature in the plasma plume produced by laser ablation of silver at fluences of 0.8-1.3 J cm(-2) at 355 nm have been studied using a time-resolving Langmuir probe. The angular dependence of the electron temperature and the magni...

  15. Comparisons of Simulated and Observed Stormtime Magnetic Intensities and Ion Plasma Parameters in the Ring Current

    Science.gov (United States)

    Chen, M. W.; Guild, T. B.; Lemon, C.; Roeder, J. L.; Le, G.; Schulz, M.

    2009-12-01

    Recent progress in ring current and plasma sheet modeling has shown the importance of a self-consistent treatment of particle transport and magnetic and electric fields in the inner magnetosphere. Models with and without self-consistency can lead to significantly different magnitudes and spatial distributions of plasma pressure and magnetic intensity during disturbed times. In this study we compare simulated and observed stormtime magnetic intensities (GOES and Polar/MFE) and ion densities (LANL/MPA and Polar/CAMMICE) to test how well self-consistent simulations can simultaneously reproduce these quantities. We simulate the ring current and plasma sheet for conditions corresponding to the 11 August 2000 storm using the self-consistent Rice Convection Model-Equilibrium (RCM-E) [Lemon et al., JGR, 2004] with a constant magnetopause location. Using the empirical IMF-dependent model of Tsyganenko and Mukai [JGR, 2003], we specify the plasma sheet pressure and density at 10 RE as the plasma boundary location in the RCM-E. The simulated ion densities at different magnetic local times agree fairly well with those from the re-analysis model of LANL/MPA densities of O’Brien and Lemon [Space Weather, 2007]. We compare the simulated magnetic intensity with the magnetic intensity measured by magnetometers on the GOES satellites at geosynchronous altitude (6.6 RE) and on the Polar satellite. Agreement between the simulated and observed magnetic intensities tends to agree better on the nightside than on the dayside in the inner magnetosphere. In particular, the model cannot account for observed drops in the dayside magnetic intensity during decreases in the solar wind pressure. We will modify the RCM-E to include a time-varying magnetopause location to simulate compressions and expansions associated with variations in the solar wind pressure. We investigate whether this will lead to improved agreement between the simulated and model magnetic intensities.

  16. Association of Irisin Plasma Levels with Anthropometric Parameters in Children with Underweight, Normal Weight, Overweight, and Obesity

    Directory of Open Access Journals (Sweden)

    Leticia Elizondo-Montemayor

    2017-01-01

    Full Text Available The correlations between irisin levels, physical activity, and anthropometric measurements have been extensively described in adults with considerable controversy, but little evidence about these relationships has been found in children. The objective of this study is to correlate the plasma levels of irisin in underweight, normal weight, overweight, and obese children with anthropometric parameters and physical activity levels. A cross-sample of 40 children was divided into the following groups on the basis of body mass index (BMI percentile. The correlations of plasma irisin levels with physical activity, anthropometric, and metabolic measurements were determined. Plasma irisin levels (ng/mL were lower for the underweight group (164.2 ± 5.95 than for the normal weight and obese groups (182.8 ± 5.58; p<0.05. Irisin levels correlated positively with BMI percentile (0.387, waist circumference (0.373, and fat-free mass (0.353; p<0.05, but not with body muscle mass (−0.027. After a multiple linear regression analysis, only BMI percentile (0.564; p<0.008 showed a positive correlation with irisin. Our results indicated no association with metabolic parameters. A negative correlation with physical activity was observed. Interrelationships among body components might influence irisin levels in children.

  17. Influence of Discharge Parameters on Tuned Substrate Self-Bias in an Radio-Frequency Inductively Coupled Plasma

    Institute of Scientific and Technical Information of China (English)

    Ding Zhenfeng; Sun Jingchao; Wang Younian

    2005-01-01

    The tuned substrate self-bias in an rf inductively coupled plasma source is controlled by means of varying the impedance of an external LC network inserted between the substrate and the ground. The influencing parameters such as the substrate axial position, different coupling coils and inserted resistance are experimentally studied. To get a better understanding of the experimental results, the axial distributions of the plasma density, electron temperature and plasma potential are measured with an rf compensated Langmuir probe; the coil rf peak-to-peak voltage is measured with a high voltage probe. As in the case of changing discharge power, it is found that continuity, instability and bi-stability of the tuned substrate bias can be obtained by means of changing the substrate axial position in the plasma source or the inserted resistance. Additionally,continuity can not transit directly into bi-stability, but evolves via instability. The inductance of the coupling coil has a substantial effect on the magnitude and the property of the tuned substrate bias.

  18. Influence of ultrasound operating parameters on ultrasound-induced thrombolysis in vitro.

    Science.gov (United States)

    Schäfer, Simon; Kliner, Stefan; Klinghammer, Lutz; Kaarmann, Hans; Lucic, Ivan; Nixdorff, Uwe; Rosenschein, Uri; Daniel, Werner G; Flachskampf, Frank A

    2005-06-01

    The effect of operating parameters on the thrombolytic potency of ultrasound (US) is important for potential therapeutic applications, but is not fully understood. Fresh human whole-blood thrombi were exposed in vitro to focused US from a diagnostic transducer driven by an impulse generator via an amplifier to vary duration (10 to 60 min), intensity (7 to 90 W/cm(2)), frequency (2 to 4.5 MHz), pulsed wave duty cycle (1:5 to 1:100 and continuous wave mode) and pulse length (100 to 400 micros). Segments of thrombi (498 +/- 73 mg) were submersed and insonated in saline solution. Thrombolytic efficiency was expressed as percentage loss of mass compared with controls (noninsonified thrombi). Ultrasound exposure achieved a significantly higher thrombolysis than no US, 56 +/- 16 % vs. 29 +/- 11 % (n = 232, p logarithmic relationship with duty cycle in pulsed mode (r(2) = 0.86) and a modest direct effect of pulse length (r(2) = 0.57, p < 10(-5)). Thus, thrombolytic efficiency of US depends directly on duration, intensity, duty cycle and pulse length and inversely, on frequency.

  19. Effect of Some Operating Parameters on the Reversing Continuous Countercurrent Extraction Process

    Directory of Open Access Journals (Sweden)

    Waigoon RITTIRUT

    2009-06-01

    Full Text Available The effect of some operating parameters on the reversing continuous countercurrent extraction process including the degree of inclination of the extractor and the percent forward progression by a screw conveyor was reported. Garcinia fruit was selected as model solid while sucrose was used as soluble solid for the diffusion system. The results showed that the degree of inclination provided certain effect on concentration profile, however was still ambiguous. For experimental purpose, 5, 7 or 10° can be used. Nevertheless, the solid and liquid phase were not in contact at the end point of the extraction unit in the case of 7° and 10° where the specified draft was 1.6. Based on the highest yield, a slope of 10° should be chosen. For a percent forward progression range of 10 - 20 %, the concentration profiles for both liquid and solid phase were almost identical. However, the lowest 5 % percent forward progression led to highest concentration profile for the liquid phase.Keywords:

  20. Influence of operating parameters on electrocoagulation of C.I. disperse yellow 3

    Directory of Open Access Journals (Sweden)

    Djamel Ghernaout

    2014-12-01

    Full Text Available This work deals with the electrocoagulation (EC process for an organic dye removal. The chosen organic dye is C.I. disperse yellow 3 (DY which is used in textile industry. Experiments were performed in batch mode using Al electrodes and for comparison purposes Fe electrodes. The experimental set-up was composed of 1 L beaker, two identical electrodes which are separated 2 cm from each other. The main operating parameters influencing EC process were examined such as pH, supporting electrolyte concentration CNaCl, current density i, and DY concentration. High performance EC process was shown during 45 min for 200 mg/L dye concentration at i = 350 A m-2 (applied voltage 12 V and CNaCl = 1 g L-1 reaching 98 % for pHs 3 and 10 and 99 % for pH 6. After 10 min, DY was also efficiently removed (86 % showing that EC process may be conveniently applied for textile industry wastewater treatment. EC using Fe electrodes exhibited slightly lower performance comparing EC using Al electrodes.

  1. Atomic Decomposition and Boundedness Criterion of Operators on Multi-parameter Hardy Spaces of Homogeneous Type

    Institute of Scientific and Technical Information of China (English)

    Guo Zhen LU; Ya Yuan XIAO

    2012-01-01

    The main purpose of this paper is to derive a new (p,q)-atomic decomposition on the multi-parameter Hardy space Hp(X1 × X2) for 0 < p0 < p ≤ 1 for some po and all 1 < q < ∞,where X1 × X2 is the product of two spaces of homogeneous type in the sense of Coifman and Weiss.This decomposition converges in both Lq(x1× X2) (for 1 < q < ∞) and Hardy space Hp(X1 × X2) (for 0 < p ≤ 1).As an application,we prove that an operator T,which is bounded on Lq(X1 × X2) for some 1 < q < ∞,is bounded from Hp(X1 × X2) to Lp(X1 × X2) if and only ifT is bounded uniformly on all (p,q)-product atoms in Lp(X1 × X2).The similar boundedness criterion from Hp(X1 × X2) to Hp(X1 × X2) is also obtained.

  2. Zero-valent iron mediated degradation of ciprofloxacin - assessment of adsorption, operational parameters and degradation products.

    Science.gov (United States)

    Perini, João Angelo de Lima; Silva, Bianca Ferreira; Nogueira, Raquel F Pupo

    2014-12-01

    The zero-valent iron (ZVI) mediated degradation of the antibiotic ciprofloxacin (CIP) was studied under oxic condition. Operational parameters such as ZVI concentration and initial pH value were evaluated. Increase of the ZVI concentration from 1 to 5gL(-1) resulted in a sharp increase of the observed pseudo-first order rate constant of CIP degradation, reaching a plateau at around 10 g L(-1). The contribution of adsorption to the overall removal of CIP and dissolved organic carbon (DOC) was evaluated after a procedure of acidification to pH 2.5 with sulfuric acid and sonication for 2 min. Adsorption increased as pH increased, while degradation decreased, showing that adsorption is not important for degradation. Contribution of adsorption was much more important for DOC removal than for CIP. Degradation of CIP resulted in partial defluorination since the fluoride measured corresponded to 34% of the theoretical value after 120 min of reaction. Analysis by liquid chromatography coupled to mass spectrometry showed the presence of products of hydroxylation on both piperazine and quinolonic rings generating fluorinated and defluorinated compounds as well as a product of the piperazine ring cleavage. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Optimization of operation parameters of 80-keV electron gun

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeong Dong; Lee, Yong Deok [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kang, Heung Sik [Pohang Accelerator Laboratory, Pohang (Korea, Republic of)

    2014-06-15

    A Slowing Down Time Spectrometer (SDTS) system is a highly efficient technique for isotopic nuclear material content analysis. SDTS technology has been used to analyze spent nuclear fuel and the pyro-processing of spent fuel. SDTS requires an external neutron source to induce the isotopic fissile fission. A high intensity neutron source is required to ensure a high for a good fissile fission. The electron linear accelerator system was selected to generate proper source neutrons efficiently. As a first step, the electron generator of an 80-keV electron gun was manufactured. In order to produce the high beam power from electron linear accelerator, a proper beam current is required form the electron generator. In this study, the beam current was measured by evaluating the performance of the electron generator. The beam current was determined by five parameters: high voltage at the electron gun, cathode voltage, pulse width, pulse amplitude, and bias voltage at the grid. From the experimental results under optimal conditions, the high voltage was determined to be 80 kV, the pulse width was 500 ns, and the cathode voltage was from 4.2 V to 4.6 V. The beam current was measured as 1.9 A at maximum. These results satisfy the beam current required for the operation of an electron linear accelerator.

  4. A study on the effects of operational parameters on bed-to-wall heat transfer

    Energy Technology Data Exchange (ETDEWEB)

    Gungor, A. [Nigde University, Nigde (Turkey). Dept. of Mechanical Engineering

    2009-08-15

    In this study the effects of operational parameters on bed-to-wall heat transfer in CFBs are investigated such as solids volume fraction, particle diameter, suspension density, solid circulation rate. Based on a previously developed 2D CFB model, a modified cluster renewal model is used in this investigation. The model uses the particle-based approach (PBA) and integrates the hydrodynamics and combustion aspects. The study is also validated with experimental data. As a result of this study, it is observed that the bed-to-wall heat transfer coefficients are strongly dependent on particle diameter and solids concentration at the riser wall. The smaller particles result in higher heat transfer coefficients than larger particles for the same solids volume fraction values. The heat transfer coefficient increases with suspension density. However, at a constant suspension density, the superficial velocity does not have a significant influence on the heat transfer coefficient. PBA is satisfactorily adapted to cluster renewal model so that to define the bed-to-wall heat transfer mechanisms for the upper zone.

  5. Characteristic parameters and operational curves of γ-Al2O3 nanofiltration membranes

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    The γ-Al2O3 nanofiltration membranes were manufactured by the sol-gel technique. The result of N2 adsorption and desorption test indicates that the characteristic parameters of the membranes: BJH desorption average pore diameter, BJH desorption cumulative volume of pores and BET surface area are about 3.9 nm, 0.33 cm3/g and 245 m2/g respectively, and the pore size distribution is very narrow. The operational curves of γ-Al2O3 nanofiltration membranes of the Ca2+ retention rate vs the trans-membrane pressure, feed concentration of solution treated and pH of solution treated were studied for the first time. It is found that the retention rate for Ca2+ increases with the transmembrane pressure increasing and decreases with the feed concentration of CaCl2 solution increasing. The retention of Ca2+ is very much dependent on the pH of the solution. Minimal Ca2+ retention rate is found at the isoelectric point (pH = 7.5).

  6. Lupin seeds lower plasma lipid concentrations and normalize antioxidant parameters in rats

    Directory of Open Access Journals (Sweden)

    Osman, M.

    2011-06-01

    Full Text Available This study was designed to test bitter and sweet lupin seeds for lipid-lowering and for their antioxidative activities in hypercholesterolemic rats. The levels of plasma lipid, malondialdehyde (MDA and whole blood reduced glutathione (GSH, as well as the activities of transaminases (ALT and AST, lactate dehydrogenase (LDH in plasma, superoxide dismutase (SOD, glutathione peroxidase (GPx in erythrocytes and plasma glutathione reductase (GR, glutathione-S-transferase (GST and catalase (CAT were examined. A hypercholesterolemia-induced diet manifested in the elevation of total lipids (TL, total cholesterol (TC, triglycerides (TG, LDL-C and MDA levels, ALT, AST, LDH activities and the depletion of GSH and enzymic antioxidants. The supplementation of a hypercholesterolemia-induced diet with bitter and sweet lupin seeds significantly lowered the plasma levels of TL, TC, TG and LDL-C. ALT, AST and LDH activities slightly decreased in treated groups compared with the hypercholesterolemic group (HC. Furthermore, the content of GSH significantly increased while MDA significantly decreased in treated groups compared with the HC group. In addition, the bitter lupin seed group improved enzymic antioxidants compared with the HC group. In general, the results indicated that the bitter lupin seed supplements are better than those containing sweet lupin seeds. These results suggested that the hypocholesterolemic effect of bitter and sweet lupin seed supplements might be due to their abilities to lower the plasma cholesterol level as well as to slow down the lipid peroxidation process and to enhance the antioxidant enzyme activity.

    Este estudio fue diseñado para evaluar semillas de altramuces dulces y amargas como agentes que bajan los lípidos y estudiar su efecto en la actividad antioxidante en ratas hipercolesterolémicas. El nivel de lípidos en plasma, malondialdehido (MDA y glutatión reducido (GSH, así como la actividad transaminasa (ALT y AST

  7. INCREASE OF THE OPERATIONAL PROPERTIES OF WELD AND PLASMA COATINGS USING NANOPOWDERS

    Directory of Open Access Journals (Sweden)

    Andrii Chornyi

    2016-07-01

    Full Text Available In this work, studies concerning determination of the oxide nanoparticles effect on structure and performance of the welds and plasma coatings were conducted. Ways of introducing nanodisperse refractory powders to the weld pool and how to cover with the deactivation of nanoparticles powder were determined. Introducing of the nanoparticles in the molten pool during the deposition and the coating was carried out by preparing a powder mixture by mechano-chemical processing in special high-energy intensive planetary mills. Structural studies of welds with nanooxides additives in the weld pool showed the formation of milled dispersed structure with microhardness 264-304 MPa. Statistical mean value of the number of non-metallic inclusions was defined. Mechanical testing of welds showed growth of the yield as well as tensile strength, when titanium and aluminum nanooxides were introduced into the weld pool. The most significant effect on these parameters has aluminum nanooxide in an amount of 0.5 vol.%, increasing the yield strength by 49 % and the tensile strength by 23 %. The toughness is mostly affected by titanium oxide in an amount of 1 vol.%., increasing its value by about 2 times. In turn, the introduction of alumina nanopowder in quantity 1,5 vol.% into the plasma coatings allowed to reduce friction and increase wear resistance of coatings by 2-3 times.

  8. Advanced operation scenarios toward high-beta, steady-state plasmas in KSTAR

    Science.gov (United States)

    Yoon, Si-Woo; Jeon, Y. M.; Woo, M. H.; Bae, Y. S.; Kim, H. S.; Oh, Y. K.; Park, J. M.; Park, Y. S.; Kstar Team

    2016-10-01

    For the realization of the fusion reactor, solving issues for high-beta steady-state operation is one of the essential topics for the present superconducting tokamaks and in this regard, KSTAR has been focusing on maximizing performance and increasing pulse length simultaneously. Typically, study on high beta operation has been focusing on advanced scenario limited at relatively short pulse discharge and partial success has been reported previously. However, it must be stressed that it is critical to verify compatibility of the developed scenario to long-pulse operation and compared with that of the short-pulse, it is turned out stable long-pulse operation is possible only with a reduced level of beta. In this work, the results of recent approaches in long-pulse operation are presented focusing respectively on high betaN, high betap and high li scenarios. For high betaN, the achieved level is close to 3 with Ip =0.4 MA, BT =1.4T and Pext 6MW and it is found to be limited by m/n =2/1 tearing mode and is also sensitive on the internal inductance. For high betap, conditions of the maximum betap is investigated mainly by parametric scans of plasma current (Ip =0.4-0.7 MA) and also neutral beam injection power (3-5MW). The achieved betap is also close to 3 with Ip =0.4 MA, BT =2.9T and Pext 6MW and it is found to be limited by heating power and without indication of MHD activities. Finally, attempt for high li discharge will be addressed on scenario development and transient results.

  9. Comparison between measured scrape-off layer plasma parameters and 2D model calculations for JET X-point discharges

    Energy Technology Data Exchange (ETDEWEB)

    Loarte, A. [JET Joint Undertaking, Abingdon, Oxon, OX14 3EA (United Kingdom); Chankin, A. [JET Joint Undertaking, Abingdon, Oxon, OX14 3EA (United Kingdom); Clement, S. [JET Joint Undertaking, Abingdon, Oxon, OX14 3EA (United Kingdom); Corrigan, G. [JET Joint Undertaking, Abingdon, Oxon, OX14 3EA (United Kingdom); Harbour, P. [JET Joint Undertaking, Abingdon, Oxon, OX14 3EA (United Kingdom); Horton, L. [JET Joint Undertaking, Abingdon, Oxon, OX14 3EA (United Kingdom); Janeschitz, G. [JET Joint Undertaking, Abingdon, Oxon, OX14 3EA (United Kingdom); Lingertat, J. [JET Joint Undertaking, Abingdon, Oxon, OX14 3EA (United Kingdom); Matthews, G. [JET Joint Undertaking, Abingdon, Oxon, OX14 3EA (United Kingdom); Simonini, R. [JET Joint Undertaking, Abingdon, Oxon, OX14 3EA (United Kingdom); Tagle, J.A. [JET Joint Undertaking, Abingdon, Oxon, OX14 3EA (United Kingdom); Taroni, A. [JET Joint Undertaking, Abingdon, Oxon, OX14 3EA (United Kingdom); Vlases, G. [JET Joint Undertaking, Abingdon, Oxon, OX14 3EA (United Kingdom)

    1995-04-01

    Modelling with the EDGE2D/U-NIMBUS code of the measured scrape-off layer plasma parameters for JET divertor discharges is presented. Model results agree with the experiment if very small values (< or {approx}0.1 m{sup 2}/s in H-modes and low power L-modes) for the anomalous particle transport diffusion coefficient in the SOL are used. While the assumption of the power flow out of the main plasma being carried equally by the electrons and the ions describes satisfactorily the global power balance for Ohmic and L-mode discharges, more power flowing out through the ion channel is consistent with the power balance in hot ion H-modes. Some sensitivity studies of the code results on the modelling hypothesis are discussed. ((orig.)).

  10. Plasma parameters and electromagnetic forces induced by the magneto hydro dynamic interaction in a hypersonic argon flow experiment

    Science.gov (United States)

    Cristofolini, Andrea; Neretti, Gabriele; Borghi, Carlo A.

    2012-08-01

    This work proposes an experimental analysis on the magneto hydro dynamic (MHD) interaction induced by a magnetic test body immersed into a hypersonic argon flow. The characteristic plasma parameters are measured. They are related to the voltages arising in the Hall direction and to the variation of the fluid dynamic properties induced by the interaction. The tests have been performed in a hypersonic wind tunnel at Mach 6 and Mach 15. The plasma parameters are measured in the stagnation region in front of the nozzle of the wind tunnel and in the free stream region at the nozzle exit. The test body has a conical shape with the cone axis in the gas flow direction and the cone vertex against the flow. It is placed at the nozzle exit and is equipped with three permanent magnets. In the configuration adopted, the Faraday current flows in a closed loop completely immersed into the plasma of the shock layer. The electric field and the pressure variation due to MHD interaction have been measured on the test body walls. Microwave adsorption measurements have been used for the determination of the electron number density and the electron collision frequency. Continuum recombination radiation and line radiation emissions have been detected. The electron temperature has been determined by means of the spectroscopic data by using different methods. The electron number density has been also determined by means of the Stark broadening of Hα and the Hβ lines. Optical imaging has been utilized to visualize the pattern of the electric current distribution in the shock layer around the test body. The experiments show a considerable effect of the electromagnetic forces produced by the MHD interaction acting on the plasma flow around the test body. A comparison of the experimental data with simulation results shows a good agreement.

  11. Parameters of the plasma of a dc pulsating discharge in a supersonic air flow

    Energy Technology Data Exchange (ETDEWEB)

    Shibkov, V. M., E-mail: shibkov@phys.msu.ru; Shibkova, L. V.; Logunov, A. A. [Moscow State University, Faculty of Physics (Russian Federation)

    2017-03-15

    A dc discharge in a cold (T = 200 K) supersonic air flow at a static pressure of 200–400 Torr was studied experimentally. The excited unsteady pulsating discharge has the form of a thin plasma channel with a diameter of ≤1 mm, stretched downstream the flow. Depending on the discharge current, the pulsation frequency varies from 800 to 1600 Hz and the electron temperature varies from 8000 to 15000 K.

  12. Plasma Oxytocin in Children with Autism and Its Correlations with Behavioral Parameters in Children and Parents

    OpenAIRE

    Husarova, Veronika Marcincakova; Lakatosova, Silvia; Pivovarciova, Anna; Babinska, Katarina; Bakos, Jan; Durdiakova, Jaroslava; Kubranska, Aneta; Ondrejka, Igor; Ostatnikova, Daniela

    2016-01-01

    Objective Oxytocin (OT) has been implicated to play an important role in autism spectrum disorders (ASD) etiology. We aimed to find out the differences in plasma OT levels between children with autism and healthy children, the associations of OT levels with particular autism symptoms and the associations of particular parental autistic traits with their ASD children OT levels. Methods We included 19 boys with autism and 44 healthy age-matched boys. OT levels were analyzed by ELISA method. Chi...

  13. Determination of Stark parameters by cross-calibration in a multi-element laser-induced plasma

    Science.gov (United States)

    Liu, Hao; Truscott, Benjamin S.; Ashfold, Michael N. R.

    2016-05-01

    We illustrate a Stark broadening analysis of the electron density Ne and temperature Te in a laser-induced plasma (LIP), using a model free of assumptions regarding local thermodynamic equilibrium (LTE). The method relies on Stark parameters determined also without assuming LTE, which are often unknown and unavailable in the literature. Here, we demonstrate that the necessary values can be obtained in situ by cross-calibration between the spectral lines of different charge states, and even different elements, given determinations of Ne and Te based on appropriate parameters for at least one observed transition. This approach enables essentially free choice between species on which to base the analysis, extending the range over which these properties can be measured and giving improved access to low-density plasmas out of LTE. Because of the availability of suitable tabulated values for several charge states of both Si and C, the example of a SiC LIP is taken to illustrate the consistency and accuracy of the procedure. The cross-calibrated Stark parameters are at least as reliable as values obtained by other means, offering a straightforward route to extending the literature in this area.

  14. The effects of process parameters on yield and properties of iron nanoparticles from ferrocene in a low-pressure plasma

    Science.gov (United States)

    Panchal, V.; Lahoti, G.; Bhandarkar, U.; Neergat, M.

    2011-08-01

    The effects of process parameters on iron nanoparticle formation and properties while using ferrocene as a precursor in a low-pressure capacitively coupled plasma are investigated. The L18 array of the Taguchi method, followed by the L4 array, is used with the notional objective of increasing the yield of nanoparticles. A study of the size, shape and composition of the particles (using transmission electron microscopy, high-resolution transmission electron microscopy, Raman spectroscopy, x-ray diffraction, CHON and inductively coupled plasma-atomic emission spectroscopy analysis) gives an insight into the role played by various process parameters. Pressure is the most critical parameter in increasing nanoparticle yield, whereas hydrogen flow plays a key role in determining the nanoparticle size and composition. Atomic hydrogen helps in removing amorphous carbon and reducing the nanoparticle size. RF power plays an important role in the dissociation of ferrocene thus also affecting the composition. Nanoparticles obtained using optimized conditions are a mixture of Fe3O4 and Fe2O3 with cluster size 25-40 nm in diameter that are further made up of 2-4 nm crystallites. Magnetic property measurements indicate that the nanoparticles are super-paramagnetic in nature.

  15. The effects of process parameters on yield and properties of iron nanoparticles from ferrocene in a low-pressure plasma

    Energy Technology Data Exchange (ETDEWEB)

    Panchal, V; Neergat, M [Department of Energy Science and Engineering, Indian Institute of Technology Bombay, Powai, Mumbai 400076 (India); Lahoti, G; Bhandarkar, U, E-mail: bhandarkar@iitb.ac.in [Department of Mechanical Engineering, Indian Institute of Technology Bombay, Powai, Mumbai 400076 (India)

    2011-08-31

    The effects of process parameters on iron nanoparticle formation and properties while using ferrocene as a precursor in a low-pressure capacitively coupled plasma are investigated. The L{sub 18} array of the Taguchi method, followed by the L{sub 4} array, is used with the notional objective of increasing the yield of nanoparticles. A study of the size, shape and composition of the particles (using transmission electron microscopy, high-resolution transmission electron microscopy, Raman spectroscopy, x-ray diffraction, CHON and inductively coupled plasma-atomic emission spectroscopy analysis) gives an insight into the role played by various process parameters. Pressure is the most critical parameter in increasing nanoparticle yield, whereas hydrogen flow plays a key role in determining the nanoparticle size and composition. Atomic hydrogen helps in removing amorphous carbon and reducing the nanoparticle size. RF power plays an important role in the dissociation of ferrocene thus also affecting the composition. Nanoparticles obtained using optimized conditions are a mixture of Fe{sub 3}O{sub 4} and Fe{sub 2}O{sub 3} with cluster size 25-40 nm in diameter that are further made up of 2-4 nm crystallites. Magnetic property measurements indicate that the nanoparticles are super-paramagnetic in nature.

  16. Preliminary Study of Ideal Operational MHD Beta Limit in HL-2A Tokamak Plasmas

    Institute of Scientific and Technical Information of China (English)

    SHEN Yong; DONG Jiaqi; HE Hongda; A. D. TURNBULL

    2009-01-01

    Magnetohydrodynamic (MHD) n=1 kink mode with n the toroidal mode number is studied and the operational beta limit, constrained by the mode, is calculated for the equilibrium of HL-2A by using the GATO code. Approximately the same beta limit is obtained for configurations with a value of the axial safety factor q0 both larger and less than 1. Without the stabilization of the conducting wall, the beta limit is found to be 0.821% corresponding to a normalized beta value of βcN=2.56 for a typical HL-2A discharge with a plasma current Ip=0.245 MA, and the scaling of βcN~constant is confirmed.

  17. Operational characteristics of the high flux plasma generator Magnum-PSI

    NARCIS (Netherlands)

    van Eck, H. J. N.; Abrams, T.; van den Berg, M. A.; Brons, S.; van Eden, G. G.; Jaworski, M. A.; Kaita, R.; van der Meiden, H. J.; Morgan, T. W.; van de Pol, M.J.; Scholten, J.; Smeets, P. H. M.; De Temmerman, G.; de Vries, P. C.; van Emmichoven, P. A. Zeijlma

    2014-01-01

    Abstract In Magnum-PSI (MAgnetized plasma Generator and \\{NUMerical\\} modeling for Plasma Surface Interactions), the high density, low temperature plasma of a wall stabilized dc cascaded arc is confined to a magnetized plasma beam by a quasi-steady state axial magnetic field up to 1.3 T. It

  18. Effects of magnesium on erythrocyte sodium-lithium countertransport and some of plasma biochemical parameters in rabbit

    Directory of Open Access Journals (Sweden)

    Samad Akbarzadeh

    2009-02-01

    Full Text Available Background: Magnesium acts as an essential cofactor for the activity of many enzymes. It regulates the work of cardiovascular system. The activity of sodium–lithium countertransport (SLC and the concentrations of plasma biochemical parameters such as VLDL, LDL-cholesterol, HDL-cholesterol, sodium, potassium, urea and creatinine are changed in cardiovascular diseases. The aim of this study was to determine the effects of magnesium on SLC activity and some of the plasma biochemical parameters. Methods: New Zealand white rabbits (weighed 1350 ± 50g were chosen for these experiments. This study was conducted through two in vitro and in vivo techniques. Through in vitro method, the effects of different concentrations of magnesium on SLC activity were investigated. In order to conduct in vivo method, the rabbits were divided into two groups (5 /group. One group was treated by MgSo4 (40 mg/kg body weight through peritoneum for two weeks. For the second group, deionized water was used. The activity of SLC and mentioned biochemical parameters were determined. Results: The results of both in vitro and in vivo studies showed that magnesium can significantly decrease the SLC activity and also causes an increase in Km and decreased Vmax/Km of the system and plasma concentrations of VLDL, LDL-cholesterol, total cholesterol and triglycerides were significantly decreased. Conclusion: Magnesium may cause a reduction in blood pressure through decreasing the SLC activity and affecting the concentrations of VLDL, LDL-cholesterol, total cholesterol and triglycerides and so improvement the cardiovascular diseases.

  19. Deployment, Commissioning and Operation of Plasma Electrode Pockels Cells in the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, P A; Ollis, C W; Hinz, A; Robb, C; Primdahl, K A; Watson, J J; O' Brien, M D; Funkhouser, W G; Biltoft, P J; Shelton, R T; Tapley, W C; DeHope, W J

    2003-12-01

    Large aperture Plasma Electrode Pockels Cells (PEPCs) are an enabling technology in the National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory. The Pockels cells allow the NIF laser to take advantage of multipass main amplifier architecture, thus reducing costs and physical size of the facility. Each Pockels cell comprises four 40-cm x 40-cm apertures arranged in a 4 x 1 array. The combination of the Pockels cell and a thin-film polarizer, also configured in a 4 x 1 array, forms an optical switch that is key to achieving the required multi-pass operation. The operation of the PEPC is a follows: Before the arrival of the laser pulse, optically transparent, low-density helium plasmas are initiated to serve as electrodes for the KDP crystals mounted in the Pockels cell. During beam propagation through the main laser cavity a longitudinal electric field is impressed on the electro-optic crystals. The polarization of the propagating beams is rotated by 90{sup o} on each of two passes, thereby allowing the beam to be trapped in the main laser amplifier cavity for a total of four passes before being switched out into the cavity spatial filter. The physics aspects of the PEPC are well documented. Consequently, this paper will emphasize the PEPC subsystem in the context of its role and relevance within the broader NIF laser system, provide a view of the complexity of the subsystem and give an overview of PEPC's interactions with other elements of NIF, including interfaces to the Beamline Infrastructure, the NIF Timing Subsystem, and the Integrated Computer Control System (ICCS); along with dependence on the Optics Production, Transport and Handling (T&H), and Assembly, Integration and Refurbishment (AIR) and Operations organizations. Further, we will discuss implementation details related to the functional blocks and individual components that comprise PEPC, with particular emphasis on the unique constraints placed on the elements and the

  20. Determination of reference ranges for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq

    Directory of Open Access Journals (Sweden)

    Al-Marzoki JM

    2012-10-01

    Full Text Available Jasim M Al-Marzoki1, Zainab W Al-Maaroof2, Ali H Kadhum31Department of Pediatrics, 2Department of Pathology, Babylon Medical College, 3Babylon Gynecology and Pediatric Teaching Hospital, Hilla, IraqBackground: The health of an individual is known to vary in different countries, in the same country at different times, and in the same individuals at different ages. This means that the condition of individuals must be related to or compared with reference data. Determination of a reference range for the healthy term newborn is clinically important in terms of various complete blood count parameters. The purpose of this study was to establish a local reference range for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq.Methods: A total of 220 mothers and their neonates were enrolled in this cross-sectional study from February 2011 to January 2012. Maternal inclusion criteria were age 15–45 years, an uneventful pregnancy, and hemoglobin ≥ 10 g. Neonatal inclusion criteria were full term (37–42 weeks and normal birth weight. The umbilical cord was immediately clamped after delivery of the baby; 3 mL of cord blood was then taken from the umbilical vein and collected in a tube containing ethylenediamine tetra-acetic acid, its plasma was analyzed for full blood count parameters by standard Coulter gram, and the differential leukocyte count was done manually.Results: Mean neonatal hemoglobin was 13.88 ± 1.34 (range 11–17.3 g/dL and mean white cell count was 10.12 ± 2.8 (range 3.1–21.6 × 109/L. Mean platelet count was 267.63 ± 60.62 (range 152–472 × 109/L. No significant differences in red cell, white cell, or platelet counts were found between males and females, except for neutrophil count. The current study shows lower levels of hemoglobin, white cells, and red cells compared with other studies, and there is agreement with some studies and disagreement with others concerning platelet count.Conclusion: Most results

  1. Characterization of operating parameters of an in vivo micro CT system

    Science.gov (United States)

    Ghani, Muhammad U.; Ren, Liqiang; Yang, Kai; Chen, Wei R.; Wu, Xizeng; Liu, Hong

    2016-03-01

    The objective of this study was to characterize the operating parameters of an in-vivo micro CT system. In-plane spatial resolution, noise, geometric accuracy, CT number uniformity and linearity, and phase effects were evaluated using various phantoms. The system employs a flat panel detector with a 127 μm pixel pitch, and a micro focus x-ray tube with a focal spot size ranging from 5-30 μm. The system accommodates three magnification sets of 1.72, 2.54 and 5.10. The in-plane cutoff frequencies (10% MTF) ranged from 2.31 lp/mm (60 mm FOV, M=1.72, 2×2 binning) to 13 lp/mm (10 mm FOV, M=5.10, 1×1 binning). The results were qualitatively validated by a resolution bar pattern phantom and the smallest visible lines were in 30-40 μm range. Noise power spectrum (NPS) curves revealed that the noise peaks exponentially increased as the geometric magnification (M) increased. True in-plane pixel spacing and slice thickness were within 2% of the system's specifications. The CT numbers in cone beam modality are greatly affected by scattering and thus they do not remain the same in the three magnifications. A high linear relationship (R2 > 0.999) was found between the measured CT numbers and Hydroxyapatite (HA) loadings of the rods of a water filled mouse phantom. Projection images of a laser cut acrylic edge acquired at a small focal spot size of 5 μm with 1.5 fps revealed that noticeable phase effects occur at M=5.10 in the form of overshooting at the boundary of air and acrylic. In order to make the CT numbers consistent across all the scan settings, scatter correction methods may be a valuable improvement for this system.

  2. Degradation of atenolol by UV/peroxymonosulfate: kinetics, effect of operational parameters and mechanism.

    Science.gov (United States)

    Liu, Xiaowei; Zhang, Tuqiao; Zhou, Yongchao; Fang, Lei; Shao, Yu

    2013-11-01

    Photoactivation of peroxymonosulfate (PMS) with UV (254nm) irradiation was used to generate the SO4(-)-based advanced oxidation process, which was adopted to degrade atenolol (ATL) in water. The second-order reaction rate constants of ATL with HO and SO4(-) were determined, and the effects of operational parameters (dose of PMS, solution pH, HCO3(-), humic acids (HA), and N2 bubbling) were evaluated as well. Finally the main transformation intermediates were identified and possible degradation pathways were proposed. The results showed that there was a linear positive correlation between the degradation rate of ATL and specific dose of PMS (1-16M PMS/M ATL). Increasing solution pH from 3 to 9 promoted elimination of ATL due to the pH-dependent effect of PMS photodecomposition, while further pH increase from 9 to 11 caused slowing down of degradation because of apparent conversion of HO to SO4(-). 1-8mM HCO3(-) exerted no more than 5.3% inhibition effect on ATL destruction, suggesting HCO3(-) was a weak inhibitor. Absorption (or complexation) and photosensitized oxidation induced by HA improved ATL degradation during the first minute of degradation process, whereas photon competition and radical scavenging effects became the leading role afterward. Bubbling with nitrogen enhanced the degradation rate due to the stripping of dissolved oxygen. Hydroxylation of aromatic ring, cleavage of ether bond, oxidation of primary and secondary amine moieties, and dimerization were involved in the degradation mechanism of ATL by UV/PMS.

  3. Correlation between the physical parameters of the i-nc-Si absorber layer grown by 27.12 MHz plasma with the nc-Si solar cell parameters

    Science.gov (United States)

    Das, Debajyoti; Mondal, Praloy

    2017-09-01

    Growth of highly conducting nanocrystalline silicon (nc-Si) thin films of optimum crystalline volume fraction, involving dominant crystallographic preferred orientation with simultaneous low fraction of microstructures at a low substrate temperature and high growth rate, is a challenging task for its promising utilization in nc-Si solar cells. Utilizing enhanced electron density and superior ion flux densities of the high frequency (∼27.12 MHz) SiH4 plasma, improved nc-Si films have been produced by simple optimization of H2-dilution, controlling the ion damage and enhancing supply of atomic-hydrogen onto the growing surface. Single junction nc-Si p-i-n solar cells have been prepared with i-nc-Si absorber layer and optimized. The physical parameters of the absorber layer have been systematically correlated to variations of the solar cell parameters. The preferred alignment of crystallites, its contribution to the low recombination losses for conduction of charge carriers along the vertical direction, its spectroscopic correlation with the dominant growth of ultra-nanocrystalline silicon (unc-Si) component and corresponding longer wavelength absorption, especially in the neighborhood of i/n-interface region recognize scientific and technological key issues that pave the ground for imminent advancement of multi-junction silicon solar cells.

  4. Evaluation of various operational and dosimetric parameters of an industrial electron beam accelerator of 2 MeV energy

    Science.gov (United States)

    Benny, P. G.; Khader, S. A.; Sarma, K. S. S.

    2014-07-01

    An industrial type 2 MeV/20 kW ILU-6 electron beam accelerator is operational in India for development of applications and technology demonstration to the Indian Industry in the field of polymer modifications (cross-linking and degradation). In order to adjust the treatment conditions and to control the good operation of the accelerator, it is necessary to study dose response as a function of various operational parameters. An experimental procedure for calibrating Cellulose Triacetate (CTA) film strip dosimeters in electron beam using total absorption graphite calorimeters is discussed and compared it with the results obtained from gamma calibration. Dosimetry data for process application, where the irradiation target is plane polymer sheet, have been obtained under various operational parameters.

  5. [Association between systemic inflammation and autoimmunity parameters and plasma lipid in patients with rheumatoid arthritis].

    Science.gov (United States)

    Xue, Chao; Liu, Wen-ling; Sun, Yi-hong; Ding, Rong-jing; Hu, Da-yi

    2011-10-01

    The purpose of this study was to observe the association between inflammation status/autoimmune antibodies and plasma lipid in patients with rheumatoid arthritis (RA). A total of 402 RA patients were admitted into our hospital during January 2008 to March 2009 and 225 RA patients who met the inclusion criteria were selected to perform a full lipid profile examination including total cholesterol (TC), high-density lipoprotein cholesterol (HDL-C), low-density lipoprotein cholesterol (LDL-C) and triglyceride (TG). Erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), rheumatoid factor (RF), anti-cyclic citrullinated peptide (anti-CCP), anti-keratin antibody (AKA), anti-perinuclear factor autoantibody (APF) and complement (C) were also evaluated. Atherogenic index of plasma (AIP) was calculate by the formula Log (TG/HDL-C). (1) There were 12.9%, 10.2% and 14.2% patients with elevated TC, LDL-C and TC respectively, patients with reduced HDL-C accounted for 43.6%. (2) C(3) was higher in elevated TC group than normal TC group (P elevated LDL-C group than in normal LDL-C group (P anti-CCP were positively correlated with LDL-C (R(2) = 0.129, P antibodies. Moreover, ESR and C(4) were predictors of increased AIP in this cohort.

  6. Optimization of plasma parameters for the production of silicon nano-crystals

    CERN Document Server

    Chaabane, N; Vach, H; Cabarrocas, P R I

    2003-01-01

    We use silane-hydrogen plasmas to synthesize silicon nano-crystals in the gas phase and thermophoresis to collect them onto a cooled substrate. To distinguish between nano-crystals formed in the plasma and those grown on the substrate, as a result of surface and subsurface reactions, we have simultaneously deposited films on a conventional substrate heated at 250 deg. C and on a second substrate cooled down to 90 deg. C. A series of samples deposited at various discharge pressures, in the range of 400 mTorr to 1.2 Torr, have been characterized by Raman spectroscopy and ellipsometry. At low pressure (400-500 mTorr), the films are amorphous on the cold substrate and micro-crystalline on the hot one. As pressure increases, gas phase reactions lead to the formation of nano-crystalline particles which are attracted by the cold substrate due to thermophoresis. Consequently, we obtain nano-crystalline silicon thin films on the cold substrate and amorphous thin films on the heated one in the pressure range of 600-900...

  7. Pulsed plasma electron sourcesa)

    Science.gov (United States)

    Krasik, Ya. E.; Yarmolich, D.; Gleizer, J. Z.; Vekselman, V.; Hadas, Y.; Gurovich, V. Tz.; Felsteiner, J.

    2009-05-01

    There is a continuous interest in research of electron sources which can be used for generation of uniform electron beams produced at E ≤105 V/cm and duration ≤10-5 s. In this review, several types of plasma electron sources will be considered, namely, passive (metal ceramic, velvet and carbon fiber with and without CsI coating, and multicapillary and multislot cathodes) and active (ferroelectric and hollow anodes) plasma sources. The operation of passive sources is governed by the formation of flashover plasma whose parameters depend on the amplitude and rise time of the accelerating electric field. In the case of ferroelectric and hollow-anode plasma sources the plasma parameters are controlled by the driving pulse and discharge current, respectively. Using different time- and space-resolved electrical, optical, spectroscopical, Thomson scattering and x-ray diagnostics, the parameters of the plasma and generated electron beam were characterized.

  8. Improved operation of a microwave pulse compressor with a laser-triggered high-pressure gas plasma switch

    Science.gov (United States)

    Shlapakovski, A.; Gorev, S.; Krasik, Ya. E.

    2016-08-01

    The influence of laser beam parameters on the output pulses of a resonant microwave compressor with a laser-triggered plasma switch was investigated. The S-band compressor, consisting of a rectangular waveguide-based cavity and H-plane waveguide tee with a shorted side arm, was filled with pressurized dry air and pumped by 1.8-μs-long microwave pulses of up to 450 kW power. A Nd:YAG laser was used to ignite the gas discharge in the tee side arm for output pulse extraction. The laser beam (at 213 nm or 532 nm) was directed along the RF electric field lines. It was found that the compressor operated most effectively when the laser beam was focused at the center of the switch waveguide cross-section. In this case, the power extraction efficiency reached ˜47% at an output power of ˜14 MW, while when the laser beam was not focused the maximal extraction efficiency was only ˜20% at ˜6 MW output power. Focusing the laser beam resulted also in a dramatic decrease (down to switch, and the jitter of the output pulses' appearance was minimized. In addition, the quality of the output pulses' waveform was significantly improved.

  9. Investigation of dependence of BN-600 reactor sector fuel cladding leak detection system responses on the operation parameters

    Directory of Open Access Journals (Sweden)

    O.I. Albutova

    2015-12-01

    Implemented studies of dependence of background on the reactor operational parameters are of practical importance and are original scientifically - similar types of research have not been done previously. Upon completion of testing and validation of the developed model using extended volume of reactor operation data the issue will be addressed of the implementation of the methodology within the composition of the SFCLDS of BN-600 and BN-800 reactors.

  10. An operational non destructive examination for ITER divertor plasma facing components

    Energy Technology Data Exchange (ETDEWEB)

    Durocher, A.; Escourbiac, F.; Farjon, J.L.; Vignal, N.; Cismondi, F. [Association Euratom-CEA Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee; Merola, M. [ITER International Team, Cadarache, 13 - St Paul Lez Durance (France); Riccardi, B. [CEFDA CSU-Garching, Garching bei Munchen (Germany)

    2007-07-01

    Full text of publication follows: To meet the power exhaust - heat flux of 20 MW/m{sup 2} - requirements of Plasma Facing Components (PFCs) during plasma operation requires control of their thermal and mechanical integrity. As heat exhaust capability and lifetime of PFCs during in-situ operation are linked to the manufacturing quality, it is an absolute requirement to develop reliable nondestructive examination methods, in particular of the CFC-CuCrZr joint, throughout the manufacturing process. Within the framework of Tokamak Tore Supra upgrade, a pioneering activity has been developed to evaluate the capability of the PFC to be efficiently cooled. In 1998 a test bed - so called SATIR - based on the heat transient method was developed by the CEA and is used today as an inspection tool in order to guarantee the PFCs performances. The technical procurement plan of ITER Divertor targets stated that all Cu cast layers on CFC armour should be subjected to 100% thermographic examination. Each ITER Party should demonstrate its technical capability to carry out the PFC with the required cooling efficiently. The ITER Divertor PFCs pose new challenges especially for the mono-block CFC thickness, and the number of full scale units to be tested which is higher than on any existing or under construction fusion machine. The SATIR method as functional inspection has been identified as the basis test to decide upon the final acceptance of the Divertor PFCs. In order to increase the detection sensitivity of SATIR test bed, several possibilities have been assessed i) the increase of the convective heat transfer coefficient, which improved in a significant way the sensitivity of SATIR diagnostic on ITER components. ii) the installation of a digital infrared camera and the improvement of the thermal signal processing, has led to a considerable increase of performances iii) an innovative process based on spatial image autocorrelation will allow to localize the interlayer defect

  11. Pre-Analytical Parameters Affecting Vascular Endothelial Growth Factor Measurement in Plasma: Identifying Confounders.

    Directory of Open Access Journals (Sweden)

    Johanna M Walz

    Full Text Available Vascular endothelial growth factor-A (VEGF-A is intensively investigated in various medical fields. However, comparing VEGF-A measurements is difficult because sample acquisition and pre-analytic procedures differ between studies. We therefore investigated which variables act as confounders of VEGF-A measurements.Following a standardized protocol, blood was taken at three clinical sites from six healthy participants (one male and one female participant at each center twice one week apart. The following pre-analytical parameters were varied in order to analyze their impact on VEGF-A measurements: analyzing center, anticoagulant (EDTA vs. PECT / CTAD, cannula (butterfly vs. neonatal, type of centrifuge (swing-out vs. fixed-angle, time before and after centrifugation, filling level (completely filled vs. half-filled tubes and analyzing method (ELISA vs. multiplex bead array. Additionally, intrapersonal variations over time and sex differences were explored. Statistical analysis was performed using a linear regression model.The following parameters were identified as statistically significant independent confounders of VEGF-A measurements: analyzing center, anticoagulant, centrifuge, analyzing method and sex of the proband. The following parameters were no significant confounders in our data set: intrapersonal variation over one week, cannula, time before and after centrifugation and filling level of collection tubes.VEGF-A measurement results can be affected significantly by the identified pre-analytical parameters. We recommend the use of CTAD anticoagulant, a standardized type of centrifuge and one central laboratory using the same analyzing method for all samples.

  12. Design and operation results of nitrogen gas baking system for KSTAR plasma facing components

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang-Tae [National Fusion Research Institute, 113 Gwahang-ro, Yuseong-gu, Daejeon 305-806 (Korea, Republic of); Kim, Young-Jin, E-mail: k43689@nfri.re.kr [National Fusion Research Institute, 113 Gwahang-ro, Yuseong-gu, Daejeon 305-806 (Korea, Republic of); Joung, Nam-Yong; Im, Dong-Seok; Kim, Kang-Pyo; Kim, Kyung-Min; Bang, Eun-Nam; Kim, Yaung-Soo [National Fusion Research Institute, 113 Gwahang-ro, Yuseong-gu, Daejeon 305-806 (Korea, Republic of); Yoo, Seong-Yeon [Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 305-764 (Korea, Republic of)

    2013-11-15

    Highlights: • Vacuum pressure in a vacuum vessel arrived at 7.24 × 10{sup −8} mbar. • PFC temperature was reached maximum 250 °C by gas temperature at 300 °C. • PFC inlet gas temperature was changed 5 °C per hour during rising and falling. • PFC gas balancing was made temperature difference among them below 8.3 °C. • System has a pre-cooler and a three-way valve to save operation energy. -- Abstract: A baking system for the Korea Superconducting Tokamak Advanced Research (KSTAR) plasma facing components (PFCs) is designed and operated to achieve vacuum pressure below 5 × 10{sup −7} mbar in vacuum vessel with removing impurities. The purpose of this research is to prevent the fracture of PFC because of thermal stress during baking the PFC, and to accomplish stable operation of the baking system with the minimum life cycle cost. The uniformity of PFC temperature in each sector was investigated, when the supply gas temperature was varied by 5 °C per hour using a heater and the three-way valve at the outlet of a compressor. The alternative of the pipe expansion owing to hot gas and the cage configuration of the three-way valve were also studied. During the fourth campaign of the KSTAR in 2011, nitrogen gas temperature rose up to 300 °C, PFC temperature reached at 250 °C, the temperature difference among PFCs was maintained at below 8.3 °C, and vacuum pressure of up to 7.24 × 10{sup −8} mbar was achieved inside the vacuum vessel.

  13. Effect of transient scrotal hyperthermia on sperm parameters, seminal plasma biochemical markers, and oxidative stress in men

    Directory of Open Access Journals (Sweden)

    Meng Rao

    2015-01-01

    Full Text Available In this experimental prospective study, we aimed to analyze the effect of transient scrotal hyperthermia on the male reproductive organs, from the perspective of sperm parameters, semen plasma biochemical markers, and oxidative stress, to evaluate whether different frequencies of heat exposure cause different degrees of damage to spermatogenesis. Two groups of volunteers (10 per group received testicular warming in a 43°C water bath 10 times, for 30 min each time: group 1: 10 consecutive days; group 2: once every 3 days. Sperm parameters, epididymis and accessory sex gland function, semen plasma oxidative stress and serum sex hormones were tested before treatment and in the 16-week recovery period after treatment. At last, we found an obvious reversible decrease in sperm concentration (P = 0.005 for Group 1 and P= 0.008 for Group 2 when the minimums were compared with baseline levels, the same below, motility (P = 0.009 and 0.021, respectively, the hypoosmotic swelling test score (P = 0.007 and 0.008, respectively, total acrosin activity (P = 0.018 and 0.009, respectively, and an increase in the seminal plasma malondialdehyde concentration (P = 0.005 and 0.017, respectively. The decrease of sperm concentration was greater for Group 2 than for Group 1 (P = 0.031. We concluded that transient scrotal hyperthermia seriously, but reversibly, negatively affected the spermatogenesis, oxidative stress may be involved in this process. In addition, intermittent heat exposure more seriously suppresses the spermatogenesis compared to consecutive heat exposure. This may be indicative for clinical infertility etiology analysis and the design of contraceptive methods based on heat stress.

  14. Optimization of the parameters of plasma liners with zero-dimensional models

    Science.gov (United States)

    Oreshkin, V. I.

    2013-11-01

    The efficiency of conversion of the energy stored in the capacitor bank of a high-current pulse generator into the kinetic energy of an imploding plasma liner is analyzed. The analysis is performed by using a model consisting of LC circuit equations and equations of motion of a cylindrical shell. It is shown that efficient energy conversion can be attained only with a low-inductance generator. The mode of an "ideal" load is considered where the load current at the final stage of implosion is close to zero. The advantages of this mode are, first, high efficiency of energy conversion (80%) and, second, improved stability of the shell implosion. In addition, for inertial confinement fusion realized by the scheme of a Z pinch dynamic hohlraum, not one but several fusion targets can be placed in the cavity on the pinch axis due to the large length of the liner.

  15. Plasma oxidative stress parameters in men and women with early stage Alzheimer type dementia.

    Science.gov (United States)

    Puertas, M C; Martínez-Martos, J M; Cobo, M P; Carrera, M P; Mayas, M D; Ramírez-Expósito, M J

    2012-08-01

    It is well known that oxidative stress is one of the earliest events in Alzheimer's disease pathogenesis, indicating that may play a key role in this disease. In our study, we measured the levels of oxidative stress indicators (TBARS and protein carbonyls content) and the non-enzymatic (glutathione (GSH) and oxidized glutathione (GSSG)) and enzymatic (glutathione peroxidase (GPx), catalase (CAT) and superoxide dismutase (SOD)) defense systems in the plasma of 46 patients diagnosed of ATD and 46 age-matched controls. We found decreased levels in total GSH in ATD patients, although healthy control women showed lower levels of total GSH than healthy control men. On the contrary, we found increased levels of TBARS and carbonyl groups content in ATD patients in both genders. The activity of the plasma antioxidant enzymes showed no changes for SOD activity in ATD patients, independently of the gender, although western blot analysis showed an increase in SOD-1 protein. CAT activity was also decreased in ATD patients, although this decrease is mainly due to the decrease found in men but not in women. However, western blot analysis did not show differences in CAT protein between controls and ATD patients. Finally, a decrease of GPx activity was found in ATD patients in both genders. However, as with CAT protein, western blot analysis did not show differences in GPx protein between controls and ATD patients. Our results suggest that there is a defect in the antioxidant defense system that is incapable of responding to increased free radical production, which may lead to oxidative damage and the development of the pathological alterations that characterize the neurodegenerative disorder of patients with ATD. Thus, oxidative damage could be one important aspect for the onset of ATD and oxidative stress markers could be useful to diagnose the illness in their earliest stages through both non-invasive, reliable and cost-affordable methods.

  16. Statistics on the parameters of nonisothermal ionospheric plasma in large mesospheric electric fields

    Science.gov (United States)

    Martynenko, S.; Rozumenko, V.; Tyrnov, O.; Manson, A.; Meek, C.

    The large V/m electric fields inherent in the mesosphere play an essential role in lower ionospheric electrodynamics. They must be the cause of large variations in the electron temperature and the electron collision frequency at D region altitudes, and consequently the ionospheric plasma in the lower part of the D region undergoes a transition into a nonisothermal state. This study is based on the databases on large mesospheric electric fields collected with the 2.2-MHz radar of the Institute of Space and Atmospheric Studies, University of Saskatchewan, Canada (52°N geographic latitude, 60.4°N geomagnetic latitude) and with the 2.3-MHz radar of the Kharkiv V. Karazin National University (49.6°N geographic latitude, 45.6°N geomagnetic latitude). The statistical analysis of these data is presented in Meek, C. E., A. H. Manson, S. I. Martynenko, V. T. Rozumenko, O. F. Tyrnov, Remote sensing of mesospheric electric fields using MF radars, Journal of Atmospheric and Solar-Terrestrial Physics, in press. The large mesospheric electric fields is experimentally established to follow a Rayleigh distribution in the interval 0 plasma.

  17. Identification of plasma-edge-related operational regime boundaries and the effect of edge instability on confinement in ASDEX Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Suttrop, W.; Kaufmann, M.; Blank, H.J. de; Bruesehaber, B.; Lackner, K.; Mertens, V.; Murmann, H.; Neuhauser, J.; Ryter, F.; Salzmann, H.; Schweinzer, J.; Stober, J. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Boltzmannstrasse 2, D-85748 Garching (Germany); Zohm, H. [Institut fuer Plasmaforschung, Universitaet Stuttgart, Pfaffenwaldring 31, D-70569 Stuttgart (Germany)

    1997-12-01

    Local edge parameters on the ASDEX Upgrade tokamak are investigated at the L-mode to H-mode transition, during phases with various types of edge-localized modes (ELMs), and at the density limit. A scaling law for the boundary electron temperature, T{sub e,b}{sup thresh} {proportional_to} n{sub e,b}{sup -0.3}B{sub t}{sup 0.8}I{sub p}{sup 0.5}, is found which describes the H-mode threshold for deuterium-puffed discharges with favourable ion {nabla}B-drift direction. The region of stable operation is bounded by type I ELMs near the ideal ballooning limit and by a minimum temperature necessary to avoid thermal instability of the plasma edge. Stationary operation with type III ELMs imposes an upper limit on the edge temperature. Within the entire range of boundary densities investigated (n{sub e,b}{<=}8x10{sup 19}m{sup -3}), both L-mode and H-mode are found to be accessible. During type I ELMy H-mode, a relation of global confinement with the edge pressure gradient is found which is connected with a loss of the favourable density dependence predicted by the ITER-92P and ITER-93H ELMy H-mode scalings. At high density, better confinement is achieved in H-modes with an edge pressure gradient below the ideal ballooning limit, e.g. during type III ELMy H-mode with impurity-seeded radiation. (author)

  18. Influence of atmospheric plasma spray parameters on YSZ coatings obtained from micro and nano structured feedstocks; Influencia de los parametros de proyeccion por plasma atmosferico en recubrimientos de YSZ obtenidos a partir de polvos micro y nanoestructurados

    Energy Technology Data Exchange (ETDEWEB)

    Carpio, P.; Bannier, E.; Borrell, A.; Salvador, M. d.; Sanchez, E.

    2014-07-01

    In the present work, the influence of atmospheric plasma spray (APS) parameters on the deposition of two commercial YSZ feedstocks, one conventional and one non-conductor's, has been studied. First the study focused on how the variability of the different parameters affects the particle behaviour during spraying. For this purpose, a sensor which enables to measure the particle temperature and velocity inside the plasma was used. Once the spraying parameters influence was known, both powders were deposited by APS onto stainless steel substrates modifying the higher influencing parameters. These coatings have been characterised and the influence of the particle behaviour on the coating microstructure and properties has been analysed. This work concludes the spraying parameters variation affects on the particle velocity and temperature inside the plasma plume and this behaviour influences, in turn but in a different way, on the final coating characteristics when using different powders (micro- and nano structured). (Author)

  19. 40 CFR Table 3 to Subpart Ec of... - Operating Parameters To Be Monitored and Minimum Measurement and Recording Frequencies

    Science.gov (United States)

    2010-07-01

    ... flow rate Hourly 1×hour ✔ ✔ Minimum pressure drop across the wet scrubber or minimum horsepower or... scrubber followed by fabric filter Wet scrubber Dry scrubber followed by fabric filter and wet scrubber Maximum operating parameters: Maximum charge rate Continuous 1×hour ✔ ✔ ✔ Maximum fabric filter...

  20. 40 CFR Table 3 to Subpart Hhh of... - Operating Parameters To Be Monitored and Minimum Measurement and Recording Frequencies

    Science.gov (United States)

    2010-07-01

    ... mercury (Hg) sorbent flow rate Hourly Once per hour ✔ ✔ Minimum pressure drop across the wet scrubber or... rural HMIWI HMIWI a with dry scrubber followed by fabric filter HMIWI a with wet scrubber HMIWI a with dry scrubber followed by fabric filter and wet scrubber Maximum operating parameters: Maximum...

  1. Structural parameter based modification of energy conscious ESPAR antenna system through optimization for WLAN’s dual-band operability

    CSIR Research Space (South Africa)

    Bembe, MJ

    2010-11-01

    Full Text Available single device. In this study the focus is on the modification of the antenna designs for dual-band functionality which is limited on the ESPAR antenna’s structural parameter. This modification should result in an antenna system which operates in both 2...

  2. DC-driven plasma gun: self-oscillatory operation mode of atmospheric-pressure helium plasma jet comprised of repetitive streamer breakdowns

    Science.gov (United States)

    Wang, Xingxing; Shashurin, Alexey

    2017-02-01

    This paper presents and studies helium atmospheric pressure plasma jet comprised of a series of repetitive streamer breakdowns, which is driven by pure DC high voltage (self-oscillatory behavior). The repetition frequency of the breakdowns is governed by the geometry of discharge electrodes/surroundings and gas flow rate. Each next streamer is initiated when the electric field on the anode tip recovers after the previous breakdown and reaches the breakdown threshold value of about 2.5 kV cm-1. One type of the helium plasma gun designed using this operational principle is demonstrated. The gun operates on about 3 kV DC high voltage and is comprised of the series of the repetitive streamer breakdowns at a frequency of about 13 kHz.

  3. Prebiotics, Prosynbiotics and Synbiotics: Can They Reduce Plasma Oxidative Stress Parameters? A Systematic Review.

    Science.gov (United States)

    Salehi-Abargouei, Amin; Ghiasvand, Reza; Hariri, Mitra

    2017-01-03

    This study assessed the effectiveness of presybiotics, prosybiotics and synbiotics on reducing serum oxidative stress parameters. PubMed/Medline, Ovid, Google Scholar, ISI Web of Science and SCOPUS were searched up to September 2016. English language randomized clinical trials reporting the effect of presybiotics, prosybiotics or synbiotic interventions on serum oxidative stress parameters in human adults were included. Twenty-one randomized clinical trials met the inclusion criteria for systematic review. Two studies investigated prebiotics, four studies synbiotics and fifteen studies probiotics. According to our systematic review, prebiotic could decrease malondialdehyde and increase superoxidative dismutase, but evidence is not enough. In comparison with fructo-oligosaccharide, inulin is much more useful for oxidative stress reduction. Using probiotics with dairy products could reduce oxidative stress significantly, but probiotic in form of supplementation did not have any effect on oxidative stress. There is limited but supportive evidence that presybiotics, prosybiotics and synbiotics are effective for reducing oxidative stress parameters. Further randomized clinical trials with longer duration of intervention especially on population with increased oxidative stress are needed to provide more definitive results before any recommendation for clinical use of these interventions.

  4. Integrated Prediction and Mitigation Methods of Materials Damage and Lifetime Assessment during Plasma Operation and Various Instabilities in Fusion Devices

    Energy Technology Data Exchange (ETDEWEB)

    Hassanein, Ahmed [Purdue Univ., West Lafayette, IN (United States)

    2015-03-31

    This report describes implementation of comprehensive and integrated models to evaluate plasma material interactions during normal and abnormal plasma operations. The models in full3D simulations represent state-of-the art worldwide development with numerous benchmarking of various tokamak devices and plasma simulators. In addition, significant number of experimental work has been performed in our center for materials under extreme environment (CMUXE) at Purdue to benchmark the effect of intense particle and heat fluxes on plasma-facing components. This represents one-year worth of work and resulted in more than 23 Journal Publications and numerous conferences presentations. The funding has helped several students to obtain their M.Sc. and Ph.D. degrees and many of them are now faculty members in US and around the world teaching and conducting fusion research. Our work has also been recognized through many awards.

  5. Frequency-tuning radiofrequency plasma source operated in inductively-coupled mode under a low magnetic field

    Science.gov (United States)

    Takahashi, Kazunori; Nakano, Yudai; Ando, Akira

    2017-07-01

    A radiofrequency (rf) inductively-coupled plasma source is operated with a frequency-tuning impedance matching system, where the rf frequency is variable in the range of 20-50 MHz and the maximum power is 100 W. The source consists of a 45 mm-diameter pyrex glass tube wound by an rf antenna and a solenoid providing a magnetic field strength in the range of 0-200 Gauss. A reflected rf power for no plasma case is minimized at the frequency of ˜25 MHz, whereas the frequency giving the minimum reflection with the high density plasma is about 28 MHz, where the density jump is observed when minimizing the reflection. A high density argon plasma above 1× {{10}12} cm-3 is successfully obtained in the source for the rf power of 50-100 W, where it is observed that an external magnetic field of a few tens of Gauss yields the highest plasma density in the present configuration. The frequency-tuning plasma source is applied to a compact and high-speed silicon etcher in an Ar-SF6 plasma; then the etching rate of 8~μ m min-1 is obtained for no bias voltage to the silicon wafer, i.e. for the case that a physical ion etching process is eliminated.

  6. DETERMINATION OF ACTIVATED SLUDGE MODEL ASDM PARAMETERS FOR WASTE WATER TREATMENT PLANT OPERATING IN THE SEQUENTIAL–FLOW TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    Dariusz Zdebik

    2015-01-01

    Full Text Available This paper presents a method for calibration of activated sludge model with the use of computer program BioWin. Computer scheme has been developed on the basis of waste water treatment plant operating in the sequential – flow technology. For calibration of the activated sludge model data of influent and treated effluent from the existing object were used. As a result of conducted analysis was a change in biokinetic model and kinetic parameters parameters of wastewater treatment facilities. The presented method of study of the selected parameters impact on the activated sludge biokinetic model (including autotrophs maximum growth rate, the share of organic slurry in suspension general operational, efficiency secondary settling tanks can be used for conducting simulation studies of other treatment plants.

  7. Determination of the Optimal Operating Parameters for Jefferson Laboratory's Cryogenic Cold Compressor Systems

    CERN Document Server

    Wilson, J D

    2003-01-01

    The technology of Jefferson Laboratory's (JLab) Continuous Electron Beam Accelerator Facility (CEBAF) and Free Electron Laser (FEL) requires cooling from one of the world's largest 2K helium refrigerators known as the Central Helium Liquefier (CHL). The key characteristic of CHL is the ability to maintain a constant low vapor pressure over the large liquid helium inventory using a series of five cold compressors. The cold compressor system operates with a constrained discharge pressure over a range of suction pressures and mass flows to meet the operational requirements of CEBAF and FEL. The research topic is the prediction of the most thermodynamically efficient conditions for the system over its operating range of mass flows and vapor pressures with minimum disruption to JLab operations. The research goal is to find the operating points for each cold compressor for optimizing the overall system at any given flow and vapor pressure.

  8. Determination of the Optimal Operating Parameters for Jefferson Laboratory's Cryogenic Cold Compressor Systems

    Energy Technology Data Exchange (ETDEWEB)

    Joe D. Wilson, Jr.

    2003-04-01

    The technology of Jefferson Laboratory's (JLab) Continuous Electron Beam Accelerator Facility (CEBAF) and Free Electron Laser (FEL) requires cooling from one of the world's largest 2K helium refrigerators known as the Central Helium Liquefier (CHL). The key characteristic of CHL is the ability to maintain a constant low vapor pressure over the large liquid helium inventory using a series of five cold compressors. The cold compressor system operates with a constrained discharge pressure over a range of suction pressures and mass flows to meet the operational requirements of CEBAF and FEL. The research topic is the prediction of the most thermodynamically efficient conditions for the system over its operating range of mass flows and vapor pressures with minimum disruption to JLab operations. The research goal is to find the operating points for each cold compressor for optimizing the overall system at any given flow and vapor pressure.

  9. Effect of co-operative fuzzy c-means clustering on estimates of three parameters AVA inversion

    Indian Academy of Sciences (India)

    Rajesh R Nair; Suresh Ch Kandpal

    2010-04-01

    We determine the degree of variation of model fitness,to a true model based on amplitude variation with angle (AVA)methodology for a synthetic gas hydrate model,using co-operative fuzzy c-means clustering,constrained to a rock physics model.When a homogeneous starting model is used,with only traditional least squares optimization scheme for inversion,the variance of the parameters is found to be comparatively high.In this co-operative methodology,the output from the least squares inversion is fed as an input to the fuzzy scheme.Tests with co-operative inversion using fuzzy c-means with damped least squares technique and constraints derived from empirical relationship based on rock properties model show improved stability,model fitness and variance for all the three parameters in comparison with the standard inversion alone.

  10. Global parameter optimization of Mather type plasma focus in the framework of the Gratton-Vargas two-dimensional snowplow model

    CERN Document Server

    Auluck, S K H

    2014-01-01

    Dense Plasma Focus (DPF) is known to produce highly energetic ions, electrons and plasma environment which can be used for breeding of short-lived isotopes, plasma nanotechnology and other material processing applications. Commercial utilization of DPF in such areas would need a design tool which can be deployed in an automatic search for the best possible device configuration for a given application. The recently revisited [S K H Auluck, Physics of Plasmas 20, 112501 (2013)] Gratton-Vargas (GV) two-dimensional analytical snowplow model of plasma focus provides a numerical formula for dynamic inductance of a Mather type plasma focus fitted to thousands of automated computations, which enables construction of such design tool. This inductance formula is utilized in the present work to explore global optimization, based on first-principles optimality criteria, in a 4-dimensional parameter-subspace of the zero-resistance GV model. The optimization process is shown to reproduce the empirically observed constancy ...

  11. Effects of fat supplementations on milk production and composition, ruminal and plasma parameters of dairy cows

    Directory of Open Access Journals (Sweden)

    L. Bailoni

    2010-04-01

    Full Text Available The effects on milk yield and quality caused by the same amount (325 g/d/cow of lipids provided by 3 different fat sources (hydrogenate palm fat, HF; calcium salt palm fat, CaSF; full-fat toasted soybean, TS, top dressed to a common total mixed ration, were investigated. Supplementations did not affect feed intake and milk yield, but markedly changed the acidic profile of milk fat. CaSF and TS significantly increased the proportions of unsaturated fatty acids of milk fat with respect to control and to HF. The 3 fat sources did not affect the concentrations of ammonia and VFA of rumen fluid. TS only slightly increased (P<0.10 plasma urea content because of a higher dietary protein supply, with respect to the other treatments. The use of a low amount of toasted and cracked full fat soybean seem to be interesting to increase the energy concentration of diets in replacement to commercial fat products and it can be use to modify the milk fat quality increasing the fraction with benefit effects on human health.

  12. Coagulation parameters as a guide for fresh frozen plasma transfusion practice: A tertiary hospital experience

    Directory of Open Access Journals (Sweden)

    Wan Haslindawani W

    2010-01-01

    Full Text Available Introduction: The appropriate use of blood and blood products means the transfusion of safe blood products only to treat a condition leading to significant morbidity or mortality, which cannot be prevented or managed effectively by other means. The safety and effectiveness of transfusion depend on the appropriate clinical use of blood and blood products. This study was conducted to review the practice of fresh frozen plasma usage (FFP for transfusion, based on the coagulation profile, requested by various departments in the Hospital Universiti Sains Malaysia (HUSM. Methodology: A retrospective review of blood bank records and coagulation profile results of the patients given FFP from October to December 2006, in Hospital USM was undertaken. The criteria set by the College of American Pathologists in 1994, were used as the guidelines. Results: One thousand six hundred and ninety-eight units of FFP were used during this study period. Only 806 (47.47% FFP units were deemed appropriate. 20.38% were based on studies without any coagulation tests prior to transfusion and 21.13% were transfused for mild prolongation of coagulation test results. About 6.41% requested FFP in the setting of normal coagulation results. Conclusion: Our results showed that a significant proportion of the FFP transfusion was not guided by the coagulation profile. We recommend that a continuous education on FFP transfusion may help to guide the appropriate request for FFP.

  13. Optimization of Operating Parameters for Minimum Mechanical Specific Energy in Drilling

    Energy Technology Data Exchange (ETDEWEB)

    Hamrick, Todd [West Virginia Univ., Morgantown, WV (United States)

    2011-01-01

    Efficiency in drilling is measured by Mechanical Specific Energy (MSE). MSE is the measure of the amount of energy input required to remove a unit volume of rock, expressed in units of energy input divided by volume removed. It can be expressed mathematically in terms of controllable parameters; Weight on Bit, Torque, Rate of Penetration, and RPM. It is well documented that minimizing MSE by optimizing controllable factors results in maximum Rate of Penetration. Current methods for computing MSE make it possible to minimize MSE in the field only through a trial-and-error process. This work makes it possible to compute the optimum drilling parameters that result in minimum MSE. The parameters that have been traditionally used to compute MSE are interdependent. Mathematical relationships between the parameters were established, and the conventional MSE equation was rewritten in terms of a single parameter, Weight on Bit, establishing a form that can be minimized mathematically. Once the optimum Weight on Bit was determined, the interdependent relationship that Weight on Bit has with Torque and Penetration per Revolution was used to determine optimum values for those parameters for a given drilling situation. The improved method was validated through laboratory experimentation and analysis of published data. Two rock types were subjected to four treatments each, and drilled in a controlled laboratory environment. The method was applied in each case, and the optimum parameters for minimum MSE were computed. The method demonstrated an accurate means to determine optimum drilling parameters of Weight on Bit, Torque, and Penetration per Revolution. A unique application of micro-cracking is also presented, which demonstrates that rock failure ahead of the bit is related to axial force more than to rotation speed.

  14. Automated Modal Parameter Estimation for Operational Modal Analysis of Large Systems

    DEFF Research Database (Denmark)

    Andersen, Palle; Brincker, Rune; Goursat, Maurice;

    2007-01-01

    In this paper the problems of doing automatic modal parameter extraction and how to account for large number of data to process are considered. Two different approaches for obtaining the modal parameters automatically using OMA are presented: The Frequency Domain Decomposition (FDD) technique and...... and a correlation-driven Stochastic Subspace Identification (SSI) technique. Special attention is given to the problem of data reduction, where many sensors are available. Finally, the techniques are demonstrated on real data....

  15. To Evaluate the Efficacy of Combination Antioxidant Therapy on Oxidative Stress Parameters in Seminal Plasma in the Male Infertility

    Science.gov (United States)

    Singh, Alpana; Radhakrishnan, Gita; Banerjee, B.D.

    2016-01-01

    Introduction Infertility is defined as inability to conceive after 1 year of unprotected intercourse and it affects 7% of male population and 8–10% of couples. According to estimates WHO, 13-19 million couples in India are infertile. Oxidative stress is the causative factor in 25% of infertile males. Aim To study the efficacy of antioxidant therapy on oxidative stress parameters in seminal plasma of infertile male. Materials and Methods Forty patients of male infertility were enrolled in study after two abnormal semen analyses reports at 2-3 weeks interval, of oligozoospermia and/or asthenozoospermia, as per WHO guide line 1999. First semen sample was collected at a time of enrollment of study and second semen sample was collected three months after combined antioxidant therapy. Semen samples from the infertile male (the second confirmatory sample of oligoasthenozoospermia) were taken and after liquefaction semen sample were utilized for various analyses, 0.5 ml of sample for standard semen analysis, 1.2 ml sample for separation of seminal plasma to evaluate Oxidative stress (OS) parameters like Malondialdehyde (MDA), Protein Carbonyl (PC) and antioxidant capacity by Glutathione (GSH). We followed the patient for three months after completion of the treatment. Results Semen parameters – Out of 40 patients recruited in the study group 7 patients had only oligospermia (1 to 20 million/ml) and 31 patients had oligoasthenozoospermia (motility range 0-50%) and 2 patients had oligoasthenoteratozoospermia. There was no patient with asthenospermia alone as abnormal semen parameters. After the three months treatment with combined antioxidants the semen parameters like count (mean SD = -1.70±1.44) and motility (mean +SD= -9.56±9.05) were significantly increased (p-value=0.000). Oxidative Stress Assessment – The level of MDA which is a marker of oxidative stress was significantly lower after the three months therapy of antioxidants (p-value=0.002) whereas another

  16. Measurement of the Operating Parameters and Numerical Analysis of the Mechanical Subsystem

    Science.gov (United States)

    Božek, Pavol; Turygin, Yuri

    2014-08-01

    Submission is focused on completing the information system about quality, operation, automatic testing and new evaluating method of vehicle subsystem. Numeric analysis is carried out on the base of automatic collection and systematic recording of commercial car operation. Proposed new information system about operation and trial process allows verification according to the proposed method. Critical components verified in laboratory conditions are detected by numeric analysis of reliability. Quality level increasing not only for final product, but also related automatic test laboratory for cars is the result of respecting these principles.

  17. Measurement of the Operating Parameters and Numerical Analysis of the Mechanical Subsystem

    Directory of Open Access Journals (Sweden)

    Božek Pavol

    2014-08-01

    Full Text Available Submission is focused on completing the information system about quality, operation, automatic testing and new evaluating method of vehicle subsystem. Numeric analysis is carried out on the base of automatic collection and systematic recording of commercial car operation. Proposed new information system about operation and trial process allows verification according to the proposed method. Critical components verified in laboratory conditions are detected by numeric analysis of reliability. Quality level increasing not only for final product, but also related automatic test laboratory for cars is the result of respecting these principles.

  18. Production of aerosols by optical catapulting: Imaging, performance parameters and laser-induced plasma sampling rate

    Science.gov (United States)

    Abdelhamid, M.; Fortes, F. J.; Fernández-Bravo, A.; Harith, M. A.; Laserna, J. J.

    2013-11-01

    Optical catapulting (OC) is a sampling and manipulation method that has been extensively studied in applications ranging from single cells in heterogeneous tissue samples to analysis of explosive residues in human fingerprints. Specifically, analysis of the catapulted material by means of laser-induced breakdown spectroscopy (LIBS) offers a promising approach for the inspection of solid particulate matter. In this work, we focus our attention in the experimental parameters to be optimized for a proper aerosol generation while increasing the particle density in the focal region sampled by LIBS. For this purpose we use shadowgraphy visualization as a diagnostic tool. Shadowgraphic images were acquired for studying the evolution and dynamics of solid aerosols produced by OC. Aluminum silicate particles (0.2-8 μm) were ejected from the substrate using a Q-switched Nd:YAG laser at 1064 nm, while time-resolved images recorded the propagation of the generated aerosol. For LIBS analysis and shadowgraphy visualization, a Q-switched Nd:YAG laser at 1064 nm and 532 nm was employed, respectively. Several parameters such as the time delay between pulses and the effect of laser fluence on the aerosol production have been also investigated. After optimization, the particle density in the sampling focal volume increases while improving the aerosol sampling rate till ca. 90%.

  19. One Form of Lyapunov Operator for Stochastic Dynamic System with Markov Parameters

    Directory of Open Access Journals (Sweden)

    Taras Lukashiv

    2016-01-01

    Full Text Available The form of weak infinitesimal operator of Lyapunov type on solutions of stochastic dynamic systems of random structure with constant delay which exist under the action of Markov perturbations is obtained.

  20. Effects of oral powder electrolyte administration on packed cell volume, plasma chemistry parameters, and incidence of colic in horses participating in a 6-day 162-km trail ride.

    Science.gov (United States)

    Walker, Wade T; Callan, Robert J; Hill, Ashley E; Tisher, Kelly B

    2014-08-01

    This study evaluated the effects of administering oral powder electrolytes on packed cell volume (PCV), plasma chemistry parameters, and incidence of colic in horses participating on a 6-day 162-km trail ride in which water was not offered ad libitum. Twenty-three horses received grain with powder electrolytes daily while 19 control horses received grain only. Horses were ridden approximately 32 km a day at a walk or trot. Packed cell volume and plasma chemistry parameters were analyzed daily. Episodes of colic were diagnosed and treated by a veterinarian unaware of treatment group allocation. Blood parameters and incidence of colic were compared between treatment groups. Electrolyte administration did not alter PCV or plasma chemistry parameters compared to controls. The incidence of colic was significantly higher in treated horses (P = 0.05). Oral powder electrolytes did not enhance hydration status or electrolyte homeostasis and may be associated with colic in horses participating on long distance trail rides similar to this model.

  1. Optimization of Process Parameters with Minimum Thrust Force and Torque in Drilling Operation Using Taguchi Method

    Directory of Open Access Journals (Sweden)

    Suleyman Neseli

    2014-10-01

    Full Text Available This research outlines the Taguchi optimization methodology, which is applied to optimize cutting parameters in drilling of AISI 1040 steel. The drilling parameters evaluated are cutting speed, feed rate, and helix angle. Series of experiments are conducted to relate the cutting parameters on the thrust force and torque. L27(313 orthogonal array, signal-to-noise ratio is employed to analyze the influence of these parameters on thrust force and torque during drilling. Analysis of variance (ANOVA is used to study the effect of process parameters on machining process. The study shows that the Taguchi method is suitable to solve the stated problem with the minimum number of trials. The main objective is to find the important factors and combination of factors that influence the machining process to achieve low thrust force and torque. The analysis of the Taguchi method indicates that the feed rate is the most significant factor affecting the thrust force, while the cutting speed contributes the most to the torque.

  2. Set-up and first operation of a plasma oven for treatment of low level radioactive wastes

    Directory of Open Access Journals (Sweden)

    Nachtrodt Frederik

    2014-01-01

    Full Text Available An experimental device for plasma treatment of low and intermediate level radioactive waste was built and tested in several design variations. The laboratory device is designed with the intention to study the general effects and difficulties in a plasma incineration set-up for the further future development of a larger scale pilot plant. The key part of the device consists of a novel microwave plasma torch driven by 200 W electric power, and operating at atmospheric pressure. It is a specific design characteristic of the torch that a high peak temperature can be reached with a low power input compared to other plasma torches. Experiments have been carried out to analyze the effect of the plasma on materials typical for operational low-level wastes. In some preliminary cold tests the behavior of stable volatile species e. g., caesium was investigated by TXRF measurements of material collected from the oven walls and the filtered off-gas. The results help in improving and scaling up the existing design and in understanding the effects for a pilot plant, especially for the off-gas collection and treatment.

  3. Study on the effect of hydrogen addition on the variation of plasma parameters of argon-oxygen magnetron glow discharge for synthesis of TiO2 films

    Directory of Open Access Journals (Sweden)

    Partha Saikia

    2016-04-01

    Full Text Available We report the effect of hydrogen addition on plasma parameters of argon-oxygen magnetron glow discharge plasma in the synthesis of H-doped TiO2 films. The parameters of the hydrogen-added Ar/O2 plasma influence the properties and the structural phases of the deposited TiO2 film. Therefore, the variation of plasma parameters such as electron temperature (Te, electron density (ne, ion density (ni, degree of ionization of Ar and degree of dissociation of H2 as a function of hydrogen content in the discharge is studied. Langmuir probe and Optical emission spectroscopy are used to characterize the plasma. On the basis of the different reactions in the gas phase of the magnetron discharge, the variation of plasma parameters and sputtering rate are explained. It is observed that the electron and heavy ion density decline with gradual addition of hydrogen in the discharge. Hydrogen addition significantly changes the degree of ionization of Ar which influences the structural phases of the TiO2 film.

  4. Chemical compositions and plasma parameters of planetary nebulae with Wolf-Rayet and wels type central stars

    CERN Document Server

    Girard, P; Acker, A

    2006-01-01

    Aims: Chemical compositions and other properties of planetary nebulae around central stars of spectral types [WC], [WO], and wels are compared with those of `normal' central stars, in order to clarify the evolutionary status of each type and their interrelation. Methods: We use plasma diagnostics to derive from optical spectra the plasma parameters and chemical compositions of 48 planetary nebulae. We also reanalyze the published spectra of a sample of 167 non-WR PN. The results as well as the observational data are compared in detail with those from other studies of the objects in common. Results: The central star's spectral type is clearly correlated with electron density, temperature and excitation class of the nebula, [WC] nebulae tend to be smaller than the other types. All this corroborates the view of an evolutionary sequence from cool [WC 11] central stars inside dense, low excitation nebulae towards hot [WO 1] stars with low density, high excitation nebulae. The wels PN, however, appear to be a separ...

  5. Evaluation of the Effect of Different Plasma-Nitriding Parameters on the Properties of Low-Alloy Steel

    Science.gov (United States)

    Zdravecká, Eva; Slota, Ján; Solfronk, Pavel; Kolnerová, Michaela

    2017-07-01

    This work is concerned with the surface treatment (ion nitriding) of different plasma-nitriding parameters on the characteristics of DIN 1.8519 low-alloy steel. The samples were nitrided from 500 to 570 °C for 5-40 h using a constant 25% N2-75% H2 gaseous mixture. Lower temperature (500-520 °C) favors the formation of compound layers of γ' and ɛ iron nitrides in the surface layers, whereas a monophase γ'-Fe4 N layer can be obtained at a higher temperature. The hardness of this layer can be obtained when nitriding is performed at a higher temperature, and the hardness decreases when the temperature increases to 570 °C. These results indicate that pulsed plasma nitriding is highly efficient at 550 °C and can form thick and hard nitrided layers with satisfactory mechanical properties. The results show the optimized nitriding process at 540 °C for 20 h. This process can be an interesting means of enhancing the surface hardness of tool steels to forge dies compared to stamped steels with zinc coating with a reduced coefficient of friction and improving the anti-sticking properties of the tool surface.

  6. The influence of active screen plasma nitriding parameters on corrosion behavior of a low-alloy steel

    Energy Technology Data Exchange (ETDEWEB)

    Ahangarani, Sh., E-mail: ahangarani@irost.i [Department of Advanced Materials and Renewable Energies, Iranian Research Organization for Science and Technology (IROST), P.O. Box 15815-3538, Tehran (Iran, Islamic Republic of); Sabour, A.R. [Department of Materials Engineering, Tarbiat Modarres University, Tehran (Iran, Islamic Republic of); Mahboubi, F. [Department of Mining and Metallurgical Engineering, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Shahrabi, T. [Department of Materials Engineering, Tarbiat Modarres University, Tehran (Iran, Islamic Republic of)

    2009-09-18

    This work presents a comparative study of low-alloy steel nitriding for different possible techniques. Active screen plasma nitriding (ASPN) is a successful surface modification method that has many advantages over the conventional DC plasma nitriding (CPN). The corrosion behavior of 30CrNiMo8 low-alloy steel has been examined using anodic polarization tests in 3.5% NaCl solution under varying conditions of ASPN and CPN processes. The process variables included active screen setup parameters, treatment temperature (550 and 580 deg. C), gas mixture (25/75 and 75/25 of N{sub 2}/H{sub 2}) and treatment time (5 and 10 h) in 500 Pa pressure. The structure and phases composition of the compound layer was studied by X-ray diffraction (XRD), microhardness tests, optical microscopy and scanning electron microscopy (SEM). It was observed that ASPN treated samples surface enhanced corrosion resistance while the temperature and/or hole size of screen setup increased.

  7. Effect of mining conditions and operating parameters of longwall shearer loaders on longwall face output

    Energy Technology Data Exchange (ETDEWEB)

    Krauze, K. (Akademia Gorniczo-Hutnicza, Cracow (Poland). Katedra Maszyn Gorniczych i Urzadzen Utylizacji Odpadow)

    1993-03-01

    Presents analytical relationships between a shearer's feed rate and web, longwall height and length, and output from a longwall face. Critical values of parameters that permit an assumed production to be achieved are provided in a table. It is maintained that the most effective factors that help to achieve a higher face output are: increased web and shorter times of longwall equipment advance and a shorter time of a single cut. Feed rates of up to 10 m/min are recommended. Interrelations between individual parameters of shearer loaders are discussed. 2 refs.

  8. Bibliography of Documents Related to the Theory, Operation, Performance and Applications of Coaxial Plasma Guns. Revision

    Science.gov (United States)

    1990-11-01

    Kelly, H., Milanese, M., Pouzo, J. and Rodriguez- Trelles , "Recent Plasma Focus Research," in Proceedings of the Seventh International Conference on...1971. Bostick, W. H., Nardi, V., Prior, W. J. and Rodriguez- Trelles , F., "On the Nature of Highly Localized X-Ray Sources in the Plasma Focus," in...Prior, W. and Rodriguez- Trelles , F., "Intensity Anisotropy and Fine Structure in the X-Ray Images of the Dense Plasma Focus," in Proceedings of the

  9. Biogas production from wheat straw and manure--impact of pretreatment and process operating parameters.

    Science.gov (United States)

    Risberg, Kajsa; Sun, Li; Levén, Lotta; Horn, Svein Jarle; Schnürer, Anna

    2013-12-01

    Non-treated or steam-exploded straw in co-digestion with cattle manure was evaluated as a substrate for biogas production compared with manure as the sole substrate. All digestions were performed in laboratory-scale CSTR reactors (5L) operating with an organic loading late of approximately 2.8 g VS/L/day, independent of substrate mixture. The hydraulic retention was 25 days and an operating temperature of 37, 44 or 52°C. The co-digestion with steam exploded straw and manure was evaluated with two different mixtures, with different proportion. The results showed stable performance but low methane yields (0.13-0.21 N L CH4/kg VS) for both manure alone and in co-digestion with the straw. Straw appeared to give similar yield as manure and steam-explosion treatment of the straw did not increase gas yields. Furthermore, there were only slight differences at the different operating temperatures.

  10. Operational characteristics of the high flux plasma generator Magnum-PSI

    Energy Technology Data Exchange (ETDEWEB)

    Eck, H.J.N. van, E-mail: h.j.n.vaneck@differ.nl [FOM Institute DIFFER, Dutch Institute For Fundamental Energy Research, Association EURATOM-FOM, Trilateral Euregio Cluster, P.O. Box 1207, 3430 BE Nieuwegein (Netherlands); Abrams, T. [Princeton Plasma Physics Laboratory, Princeton, NJ 08543 (United States); Berg, M.A. van den; Brons, S.; Eden, G.G. van [FOM Institute DIFFER, Dutch Institute For Fundamental Energy Research, Association EURATOM-FOM, Trilateral Euregio Cluster, P.O. Box 1207, 3430 BE Nieuwegein (Netherlands); Jaworski, M.A.; Kaita, R. [Princeton Plasma Physics Laboratory, Princeton, NJ 08543 (United States); Meiden, H.J. van der; Morgan, T.W.; Pol, M.J. van de; Scholten, J.; Smeets, P.H.M.; De Temmerman, G.; Vries, P.C. de; Zeijlmans van Emmichoven, P.A. [FOM Institute DIFFER, Dutch Institute For Fundamental Energy Research, Association EURATOM-FOM, Trilateral Euregio Cluster, P.O. Box 1207, 3430 BE Nieuwegein (Netherlands)

    2014-10-15

    Highlights: •We have described the design and capabilities of the plasma experiment Magnum-PSI. •The plasma conditions are well suited for PSI studies in support of ITER. •Quasi steady state heat fluxes over 10 MW m{sup −2} have been achieved. •Transient heat and particle loads can be generated to simulate ELM instabilities. •Lithium coating can be applied to the surfaces of samples under vacuum. -- Abstract: In Magnum-PSI (MAgnetized plasma Generator and NUMerical modeling for Plasma Surface Interactions), the high density, low temperature plasma of a wall stabilized dc cascaded arc is confined to a magnetized plasma beam by a quasi-steady state axial magnetic field up to 1.3 T. It aims at conditions that enable fundamental studies of plasma–surface interactions in the regime relevant for fusion reactors such as ITER: 10{sup 23}–10{sup 25} m{sup −2} s{sup −1} hydrogen plasma flux densities at 1–5 eV. To study the effects of transient heat loads on a plasma-facing surface, a high power pulsed magnetized arc discharge has been developed. Additionally, the target surface can be transiently heated with a pulsed laser system during plasma exposure. In this contribution, the current status, capabilities and performance of Magnum-PSI are presented.

  11. A Particle Swarm Optimization Algorithm for Optimal Operating Parameters of VMI Systems in a Two-Echelon Supply Chain

    Science.gov (United States)

    Sue-Ann, Goh; Ponnambalam, S. G.

    This paper focuses on the operational issues of a Two-echelon Single-Vendor-Multiple-Buyers Supply chain (TSVMBSC) under vendor managed inventory (VMI) mode of operation. To determine the optimal sales quantity for each buyer in TSVMBC, a mathematical model is formulated. Based on the optimal sales quantity can be obtained and the optimal sales price that will determine the optimal channel profit and contract price between the vendor and buyer. All this parameters depends upon the understanding of the revenue sharing between the vendor and buyers. A Particle Swarm Optimization (PSO) is proposed for this problem. Solutions obtained from PSO is compared with the best known results reported in literature.

  12. 40 CFR 63.9306 - What are my continuous parameter monitoring system (CPMS) installation, operation, and...

    Science.gov (United States)

    2010-07-01

    ... provides a representative temperature. (ii) Use a temperature sensor with a measurement sensitivity of 4... temperature chart recorder is used, it must have a measurement sensitivity in the minor division of at least... period of the emission capture system and add-on control device operation. (3) You must record...

  13. TIME EVOLUTION OF PLASMA PARAMETERS DURING THE RISE OF A SOLAR PROMINENCE INSTABILITY

    Energy Technology Data Exchange (ETDEWEB)

    Orozco Suárez, D.; Asensio Ramos, A.; Trujillo Bueno, J. [Instituto de Astrofísica de Canarias, E-38205 La Laguna, Tenerife (Spain); Díaz, A. J., E-mail: dorozco@iac.es [Departament de Física, Universitat de les Illes Balears, E-07122 Palma de Mallorca (Spain)

    2014-04-10

    We present high-spatial resolution spectropolarimetric observations of a quiescent hedgerow prominence taken in the He I 1083.0 nm triplet. The observation consisted of a time series in sit-and-stare mode of ∼36 minutes duration. The spectrograph's slit crossed the prominence body and we recorded the time evolution of individual vertical threads. Eventually, we observed the development of a dark Rayleigh-Taylor plume that propagated upward with a velocity, projected onto the plane of the sky, of 17 km s{sup –1}. Interestingly, the plume apex collided with the prominence threads pushing them aside. We inferred Doppler shifts, Doppler widths, and magnetic field strength variations by interpreting the He I Stokes profiles with the HAZEL code. The Doppler shifts show that clusters of threads move coherently while individual threads have oscillatory patterns. Regarding the plume we found strong redshifts (∼9-12 km s{sup –1}) and large Doppler widths (∼10 km s{sup –1}) at the plume apex when it passed through the prominence body and before it disintegrated. We associate the redshifts with perspective effects while the Doppler widths are more likely due to an increase in the local temperature. No local variations of the magnetic field strength associated with the passage of the plume were found; this leads us to conclude that the plumes are no more magnetized than the surroundings. Finally, we found that some of the threads' oscillations are locally damped, what allowed us to apply prominence seismology techniques to infer additional prominence physical parameters.

  14. Biological Decolorization of C.I. Basic Green 4 Solution by Chlorella sp.:Effect of Operational Parameters

    Institute of Scientific and Technical Information of China (English)

    Khataee A. R.; Pourhassan M.; Ayazloo M.

    2009-01-01

    In recent years, the ability of microorganisms to decolorize textile wastewater has received great attention due to the environmental persistence and toxicity of these pollutants. In this paper biological decolorization of triphenylmethane dye, C.I. Basic Green 4 (BG 4), by Chlorella species was investigated. The effect of operational parameters (temperature, pH, initial dye concentration and algal concentration) on decolorization efficiency was examined. Results indicated that the desired initial pH was 9. The stability and efficiency of the algae in long-term repetitive operations were also examined. Michaelis-Menten kinetics was employed to describe the apparent correlation between the decolorization rate and dye concentration. The optimal kinetic parameters, Vmax (specific decolorization rate) and Km (maximum specific decolorization rate) were 4.6 mg dye g cell-1 h-1and 151.0 mg L-1, respectively. Fig 10, Tab 2, Ref24

  15. Optimal operation for 3 control parameters of Texaco coal-water slurry gasifier with MO-3LM-CDE algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Cuiwen; Zhang, Yakun; Gu, Xingsheng [Ministry of Education, East China Univ. of Science and Technology, Shanghai (China). Key Lab. of Advanced Control and Optimization for Chemical Processes

    2013-07-01

    Optimizing operation parameters for Texaco coal-water slurry gasifier with the consideration of multiple objectives is a complicated nonlinear constrained problem concerning 3 BP neural networks. In this paper, multi-objective 3-layer mixed cultural differential evolution (MO-3LM-CDE) algorithms which comprise of 4 multi-objective strategies and a 3LM-CDE algorithm are firstly presented. Then they are tested in 6 benchmark functions. Finally, the MO-3LM-CDE algorithms are applied to optimize 3 control parameters of the Texaco coal-water slurry gasifier in methanol production of a real-world chemical plant. The simulation results show that multi-objective optimal results are better than the respective single-objective optimal operations.

  16. The effect of tape casting operational parameters on the quality of adjacently graded ceramic film

    DEFF Research Database (Denmark)

    Bulatova, Regina; Gudik-Sørensen, Mads; Della Negra, Michela;

    2016-01-01

    For small length tape casting of ceramic slurries varying green film thickness is often a problem. To optimise this, the following parameters were investigated: single blade, double blade, using a pump system and a modelled speed change mode have been analysed. Advantages and limitations of every...... method are described here. The tape casting experiments were built to be generic in order to allow the control of various processing conditions. From these results, the single-blade technique was chosen for a study of side-by-side tape casting. The influence of the geometric parameters of partitioning...... the casting tank into chambers, on the quality of graded tape was studied. Tape casting experiments at different speeds and partition tongue lengths in combination with rheological tests revealed that high casting speeds and absence of the partition under the blade are detrimental to the formation...

  17. Experimental Investigation of Machining Parameters in Drilling Operation Using Conventional and CNC Machines on Titanium Alloy

    Directory of Open Access Journals (Sweden)

    B.Suresh kumar

    2014-05-01

    Full Text Available Titanium alloy is one of the newer materials in manufacturing industries due to its high strength to weight ratio and corrosion resistance properties. Making a hole on this component is very difficult task due to its poor machinability. Hence, the machining parameter investigation on titanium alloy material is very important for predicting the drilling performance characteristics. In addition, the modern manufacturing industries are used the conventional drilling machine and CNC drilling machines for making a hole. In the sense, the main aim of this work is to investigate the machining parameters on vibration, thrust force, torque, machining time, burr dimension, tool wear and surface roughness occurrences when drilling titanium alloy with conventional and CNC machines. The effects of spindle speed and feed rate on these responses were reported.

  18. EFFECT OF CUTTING PARAMETERS ON SUPER ALLOY IN TURNING OPERATION UNDER DRY CONDITION

    Directory of Open Access Journals (Sweden)

    P.Marimuthu

    2014-12-01

    Full Text Available Ni-base super alloys are widely used in several industrial sectors, like petrochemical and power generation due to their high performance in aggressive environments. Inconel625 is primarily a Ni–Cr– Mo alloy used in different applications for its strength, excellent fabric ability and outstanding corrosion resistance. Machining of super alloy has been found to be a challenging task it has attracted considerable research. So, it is essential to know the cutting parameters for effective machining of super alloys. The present work focuses on finding the optimal cutting parameters for turning Inconel625 to achieve minimum surface roughness (SR, tool wear (TW and maximum material removal rate (MRR in CNC turning under dry conditions using TiAlN coated cutting tool. Single response optimization is performed by Taguchi method and multi response optimization is performed by desirability function analysis.

  19. Treatment of automotive industry oily wastewater by electrocoagulation: statistical optimization of the operational parameters.

    Science.gov (United States)

    GilPavas, Edison; Molina-Tirado, Kevin; Gómez-García, Miguel Angel

    2009-01-01

    An electrocoagulation process was used for the treatment of oily wastewater generated from an automotive industry in Medellín (Colombia). An electrochemical cell consisting of four parallel electrodes (Fe and Al) in bipolar configuration was implemented. A multifactorial experimental design was used for evaluating the influence of several parameters including: type and arrangement of electrodes, pH, and current density. Oil and grease removal was defined as the response variable for the statistical analysis. Additionally, the BOD(5), COD, and TOC were monitored during the treatment process. According to the results, at the optimum parameter values (current density = 4.3 mA/cm(2), distance between electrodes = 1.5 cm, Fe as anode, and pH = 12) it was possible to reach a c.a. 95% oils removal, COD and mineralization of 87.4% and 70.6%, respectively. A final biodegradability (BOD(5)/COD) of 0.54 was reached.

  20. Biofuel and Hydrogen Influence for Operation Parameters of Spark Ignition Engine

    OpenAIRE

    Martynas Damaševičius; Alfredas Rimkus; Mindaugas Melaika; Jonas Matijošius

    2016-01-01

    Paper presents research of efficient and ecological parameters of gasoline engine working with biobuthanol (10% and 20% by volume) and addi-tionaly supplying oxygen and hydrogen (HHO) gas mixture (3.6 l/min), which was obtained from from water by electrolysis. Biobuthanol addition decreases rate of heat release, the combustion temperature and pressure are lower, which has an influence on lower nitrous oxide (NOx) emission in exhaust gases. However, biobuthanol increases carbon monoxide (CO) c...

  1. Optimization of operating parameters for efficient photocatalytic inactivation of Escherichia coli based on a statistical design of experiments.

    Science.gov (United States)

    Feilizadeh, Mehrzad; Alemzadeh, Iran; Delparish, Amin; Estahbanati, M R Karimi; Soleimani, Mahdi; Jangjou, Yasser; Vosoughi, Amin

    2015-01-01

    In this work, the individual and interaction effects of three key operating parameters of the photocatalytic disinfection process were evaluated and optimized using response surface methodology (RSM) for the first time. The chosen operating parameters were: reaction temperature, initial pH of the reaction mixture and TiO2 P-25 photocatalyst loading. Escherichia coli concentration, after 90 minutes irradiation of UV-A light, was selected as the response. Twenty sets of photocatalytic disinfection experiments were conducted by adjusting operating parameters at five levels using the central composite design. Based on the experimental data, a semi-empirical expression was established and applied to predict the response. Analysis of variance revealed a strong correlation between predicted and experimental values of the response. The optimum values of the reaction temperature, initial pH of the reaction mixture and photocatalyst loading were found to be 40.3 °C, 5.9 g/L, and 1.0 g/L, respectively. Under the optimized conditions, E. coli concentration was observed to reduce from 10(7) to about 11 CFU/mL during the photocatalytic process. Moreover, all these results showed the great significance of the RSM in developing high performance processes for photocatalytic water disinfection.

  2. Influence of Operational Parameters on the Photocatalytic Activity of Powdered TiO2 for the Reduction of CO2

    Directory of Open Access Journals (Sweden)

    Oman Zuas

    2014-07-01

    Full Text Available In this report, the results from a study on the influence of operational parameters on TiO2 photocatalytic activity for CO2 reduction under an ultraviolet-visible (UV-vis illumination are presented. The results indicated that the TiO2 was found to be active for CO2 reduction with CH3OH as the major products, while other minor products (CO, CH4, and C2H4 were also detected. In addition, the formation of such reduction products was obviously influenced by the operational parameters. Under this study, the optimum operational parameters for CO2 reduction at 298 °K were determined to be: NaOH concentration 0.2 M, TiO2 dosage 2 g/L, volume of the reaction media 75 mL, the pressure of system 800 kPa. It was also found that the increase in UV-vis illumination time have increased the yield of product formation. A possible reaction pathway for the formation of the reduction products is also discussed.

  3. Association of Seminal Plasma Total Antioxidant Capacity and Malondialdehyde Levels With Sperm Parameters in Infertile Men With Varicocele

    Directory of Open Access Journals (Sweden)

    Salimi

    2016-05-01

    Full Text Available Background Varicocele is one of the most common reasons for male infertility and could impair spermatogenesis through mechanisms that are not well known. Recently, oxidative stress has been introduced as a major reason for male infertility caused by varicocele. Objectives In the current study, we aimed to assess the TAC (total antioxidant capacity and MDA (malondialdehyde as stress oxidative markers in infertile men with varicocele and fertile men, and moreover, their correlation with sperm parameters. Patients and Methods This case control study was performed on 43 infertile men with varicocele and 46 men with proven fertility. The ferric reducing ability of plasma (FRAP and thiobarbituric acid (TBA reaction methods were used for seminal plasma TAC and MDA assay, respectively. Results Lower TAC levels (1.7 ± 0.2 vs. 1.3 ± 0.4 mmol/L, P = 0.0004 and higher MDA levels (2.5 ± 1.1 vs. 5.8 ± 1.9 mmol/L, P < 0.0001 were observed in infertile men with varicocele compared to fertile men. There was no correlation between TAC and MDA in fertile men (r = 0.02, P = 0.9, however, a negative correlation was found between TAC and MDA levels in varicocele infertile men (r = −0.44, P = 0.003. Moreover, a positive correlation was found between sperm count and sperm motility with TAC levels in varicocele infertile men (r = 0.4, P = 0.02 and r = 0.6, P < 0.0001, respectively. There was a correlation between sperm motility and TAC levels in fertile men (r = 0.5, P = 0.001, but other parameters did not correlate with TAC in this group. A negative correlation was shown between semen volume, sperm count, total sperm, sperm motility, and sperm morphology with MDA levels in varicocele infertile men (r = 0.3, P = 0.045; r = −0.4, P = 0.009; r = −0.5, P = 0.002; r = −0.5, P = 0.001 and r = −0.4, P = 0.008, respectively. There was no correlation between these parameters and MDA in fertile men. Conclusions Our findings indicated that oxidative stress could

  4. Prediction of operational parameters effect on coal flotation using artificial neural network

    Institute of Scientific and Technical Information of China (English)

    E. Jorjani; Sh. Mesroghli; S. Chehreh Chelgani

    2008-01-01

    Artificial neural network procedures were used to predict the combustible value (i.e. 100-Ash) and combustible recovery of coal flotation concentrate in different operational conditions. The pulp density, pH, rotation rate, coal particle size, dosage of collector, frother and conditioner were used as inputs to the network. Feed-forward artificial neural networks with 5-30-2-1 and 7-10-3-1 arrangements were capable to estimate the combustible value and combustible recovery of coal flotation concentrate respectively as the outputs. Quite satisfactory correlations of 1 and 0.91 in training and testing stages for combustible value and of 1 and 0.95 in training and testing stages for combustible recovery prediction were achieved. The proposed neural network models can be used to determine the most advantageous operational conditions for the expected concentrate assay and recovery in the coal flotation process.

  5. Relationship between protozoan and metazoan communities and operation and performance parameters in a textile sewage activated sludge system.

    Science.gov (United States)

    Araújo dos Santos, Liliana; Ferreira, Vânia; Pereira, Maria Olívia; Nicolau, Ana

    2014-08-01

    The present study aims at investigating the possibility of assessing performance and depuration conditions of an activated sludge wastewater treatment plant through an exploration of the microfauna. The plant, receiving textile industrial (70%) and domestic (30%) sewage, consists of a two-step biological depurating plant, with activated sludge followed by a percolating system. A total of 35 samples were analyzed during five months, and 30 taxa of protozoa and small metazoa were found. Epistylis rotans, Vorticella microstoma, Aspidisca cicada and Arcella sp. were the most frequent protozoa identified. Several significant correlations between biological, physical-chemical and operational parameters were determined, but no significant correlations could be established between biological parameters and removal efficiencies. The Sludge Biotic Index (SBI) reflected the overall state of the community but only presented statistically significant correlations with the influent total suspended solids (TSS), total suspended solids in mixed-liquor (MLTSS) and dissolved oxygen (DO). The determination of key groups and taxa along with general community parameters showed to have potential value as indicators of the depuration conditions. Despite the impossibility of correlating biological parameters and the removal efficiencies, the present study attests the value of the microfauna to assess the operation of the activated sludge systems even in the case of non-conventional plants and/or plants receiving industrial sewage.

  6. Hadronic tau decay, the renormalization group, analyticity of the polarization operators, and QCD parameters

    CERN Document Server

    Geshkenbein, B V

    2003-01-01

    The ALEPH data on hadronic tau decay are thoroughly analyzed in the framework of QCD. The perturbative calculations are performed in the (1-4)-loop approximation. The analytical properties of the polarization operators are used in the whole complex q/sup 2/ plane. It is shown that the QCD prediction for R/sub tau / agrees with the measured value R/sub tau / not only for conventional Lambda /sub 3 //sup conv/=(618+or-29) MeV but also for Lambda /sub 3//sup new/= (1666+or-7) MeV. The polarization operator calculated using the renormalization group has a nonphysical cut Ý- Lambda /sub 3//sup 2 /,0¿. If Lambda /sub 3/= Lambda /sub 3//sup conv/, the contribution of only the physical cut is deficient in the explanation of the ALEPH experiment. If Lambda /sub 3/= Lambda /sub 3//sup new/ the contribution of the nonphysical cut is very small and only the physical cut explains the ALEPH experiment. The new sum rules which follow only from analytical properties of polarization operators are obtained. Based on the sum ...

  7. Influence of plasma parameters and substrate temperature on the structural and optical properties of CdTe thin films deposited on glass by laser ablation

    Energy Technology Data Exchange (ETDEWEB)

    Quiñones-Galván, J. G.; Santana-Aranda, M. A.; Pérez-Centeno, A. [Departamento de Física, Centro Universitario de Ciencias Exactas e Ingenierías, Universidad de Guadalajara, Boulevard Marcelino García Barragán 1421, Guadalajara, Jalisco C.P. 44430 (Mexico); Camps, Enrique [Departamento de Física, Instituto Nacional de Investigaciones Nucleares, Apartado Postal 18-1027, D.F., C.P. 11801 (Mexico); Campos-González, E.; Guillén-Cervantes, A.; Santoyo-Salazar, J.; Zelaya-Angel, O. [Departamento de Física, CINVESTAV-IPN, Apartado Postal 14-740, D. F. C.P. 07360 (Mexico); Hernández-Hernández, A. [Escuela Superior de Apan, Universidad Autónoma del Estado de Hidalgo, Calle Ejido de Chimalpa Tlalayote s/n Colonia Chimalpa, Apan Hidalgo (Mexico); Moure-Flores, F. de [Facultad de Química, Materiales, Universidad Autónoma de Querétaro, Querétaro C.P. 76010 (Mexico)

    2015-09-28

    In the pulsed laser deposition of thin films, plasma parameters such as energy and density of ions play an important role in the properties of materials. In the present work, cadmium telluride thin films were obtained by laser ablation of a stoichiometric CdTe target in vacuum, using two different values for: substrate temperature (RT and 200 °C) and plasma energy (120 and 200 eV). Structural characterization revealed that the crystalline phase can be changed by controlling both plasma energy and substrate temperature; which affects the corresponding band gap energy. All the thin films showed smooth surfaces and a Te rich composition.

  8. Global parameter optimization of a Mather-type plasma focus in the framework of the Gratton-Vargas two-dimensional snowplow model

    Science.gov (United States)

    Auluck, S. K. H.

    2014-12-01

    Dense plasma focus (DPF) is known to produce highly energetic ions, electrons and plasma environment which can be used for breeding short-lived isotopes, plasma nanotechnology and other material processing applications. Commercial utilization of DPF in such areas would need a design tool that can be deployed in an automatic search for the best possible device configuration for a given application. The recently revisited (Auluck 2013 Phys. Plasmas 20 112501) Gratton-Vargas (GV) two-dimensional analytical snowplow model of plasma focus provides a numerical formula for dynamic inductance of a Mather-type plasma focus fitted to thousands of automated computations, which enables the construction of such a design tool. This inductance formula is utilized in the present work to explore global optimization, based on first-principles optimality criteria, in a four-dimensional parameter-subspace of the zero-resistance GV model. The optimization process is shown to reproduce the empirically observed constancy of the drive parameter over eight decades in capacitor bank energy. The optimized geometry of plasma focus normalized to the anode radius is shown to be independent of voltage, while the optimized anode radius is shown to be related to capacitor bank inductance.

  9. Princeton Plasma Physics Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    1990-01-01

    This report discusses the following topics: principal parameters achieved in experimental devices fiscal year 1990; tokamak fusion test reactor; compact ignition tokamak; Princeton beta experiment- modification; current drive experiment-upgrade; international collaboration; x-ray laser studies; spacecraft glow experiment; plasma processing: deposition and etching of thin films; theoretical studies; tokamak modeling; international thermonuclear experimental reactor; engineering department; project planning and safety office; quality assurance and reliability; technology transfer; administrative operations; PPPL patent invention disclosures for fiscal year 1990; graduate education; plasma physics; graduate education: plasma science and technology; science education program; and Princeton Plasma Physics Laboratory reports fiscal year 1990.

  10. Natural vibration response based damage detection for an operating wind turbine via Random Coefficient Linear Parameter Varying AR modelling

    Science.gov (United States)

    Avendaño-Valencia, L. D.; Fassois, S. D.

    2015-07-01

    The problem of damage detection in an operating wind turbine under normal operating conditions is addressed. This is characterized by difficulties associated with the lack of measurable excitation(s), the vibration response non-stationary nature, and its dependence on various types of uncertainties. To overcome these difficulties a stochastic approach based on Random Coefficient (RC) Linear Parameter Varying (LPV) AutoRegressive (AR) models is postulated. These models may effectively represent the non-stationary random vibration response under healthy conditions and subsequently used for damage detection through hypothesis testing. The performance of the method for damage and fault detection in an operating wind turbine is subsequently assessed via Monte Carlo simulations using the FAST simulation package.

  11. The influence of selected design and operating parameters on the dynamics of the steam micro-turbine

    Science.gov (United States)

    Żywica, Grzegorz; Kiciński, Jan

    2015-10-01

    The topic of the article is the analysis of the influence of selected design parameters and operating conditions on the radial steam micro-turbine, which was adapted to operate with low-boiling agent in the Organic Rankine Cycle (ORC). In the following parts of this article the results of the thermal load analysis, the residual unbalance and the stiffness of bearing supports are discussed. Advanced computational methods and numerical models have been used. Computational analysis showed that the steam micro-turbine is characterized by very good dynamic properties and is resistant to extreme operating conditions. The prototype of micro-turbine has passed a series of test calculations. It has been found that it can be subjected to experimental research in the micro combined heat and power system.

  12. Semen parameters and seminal plasma protein and biochemical profiles of dogs with benign prostatic hyperplasia after botulinum toxin type A intraprostatic injection

    Directory of Open Access Journals (Sweden)

    Tathiana Ferguson Motheo

    2014-06-01

    Full Text Available This study aimed to determine the effects of different concentrations of botulinum toxin type A (BT-A on semen parameters, and seminal plasma biochemical and protein profiles of dogs with benign prostatic hyperplasia (BPH. Eighteen sexually intact male dogs with BPH were randomly divided in three groups, and received an intraprostatic injection of saline solution (control group - CG, 250UI (GI or 500UI (GII of BT-A under transabdominal ultrasound guidance. Semen was collected at baseline, 2, 4 and 8 weeks after treatment. Semen parameters were determined and seminal plasma pH, total protein (TP, total chlorides (TC, calcium (Ca, potassium (K, and sodium (Na concentrations were assessed. One-dimensional sodium dodecyl sulfatepolyacrilamide gel eletrophoresis (SDS- PAGE was performed to determine seminal plasma protein profile. Sperm parameters and seminal plasma pH, TP, TC, Ca and K mean values did not change significantly at any time point and among treated groups (P>0.05. The SDS-PAGE analysis of the pooled fractions identified 31 protein bands with molecular weights ranging from 3.9 to 106.2kDA in all treatment groups during the entire evaluation period. Regardless the used dose, intraprostatic BT-A injection do not alter semen parameters and seminal plasma biochemical and protein profiles of dogs with BPH.

  13. Pre and per operative prediction of difficult laparoscopic cholecystectomy using clinical and ultrasonographic parameters

    Directory of Open Access Journals (Sweden)

    Gaurav Gupta

    2015-11-01

    Methods: In 50 consecutive patients who underwent LC during 2013 to 2014 patient's characteristics, clinical history, laboratory data, ultrasonography results and intraoperative details were prospectively analyzed to determine predictors of difficult LC. Results: Of 50 patients 3 (06% required conversion to open cholecystectomy. Significant predictors of conversion were obscured anatomy of Calot's due to adhesions, sessile gall bladder, male gender and gall bladder wall thickness >3 mm. Conclusions: With preoperative clinical and ultrasonographic parameters, proper patient selection can be made to help predict difficult LC and a likelihood of conversion to open cholecystectomy. [Int J Res Med Sci 2015; 3(11.000: 3342-3346

  14. PARAMETER DETERMINATION FOR ADDITIONAL OPERATING FORCE MECHANISM IN DEVICE FOR PNEUMO-CENTRIFUGAL MACHINING OF BALL-SHAPED WORKPIECES

    Directory of Open Access Journals (Sweden)

    A. A. Sukhotsky

    2014-01-01

    Full Text Available The paper describes development of the methodology for optimization of parameters for an additional operating force mechanism in a device for pneumo-centrifugal machining of glass balls. Specific feature in manufacturing glass balls for micro-optics in accordance with technological process for obtaining ball-shaped workpieces is grinding and polishing of spherical surface in a free state. In this case component billets of future balls are made in the form of cubes and the billets are given preliminary a form of ball with the help of rough grinding. An advanced method for obtaining ball-shaped work-pieces from brittle materials is a pneumocentrifugal machining. This method presupposes an application of two conic rings with abrasive working surfaces which are set coaxially with large diameters to each other and the billets are rolled along these rings. Rotation of the billets is conveyed by means of pressure medium.The present devices for pneumo-centrifugal machining are suitable for obtaining balls up to 6 mm. Machining of the work-pieces with full spherical surfaces and large diameter is non-productive due to impossibility to ensure a sufficient force on the billet in the working zone. For this reason the paper proposes a modified device where an additional force on the machined billet is created by upper working disc that is making a reciprocating motion along an axis of abrasive conic rings. The motion is realized with the help of a cylindrical camshaft mechanism in the form of a ring with a profile working end face and the purpose of present paper is to optimize parameters of the proposed device.The paper presents expressions for calculation of constitutive parameters of the additional operating force mechanism including parameters of loading element motion, main dimensions of the additional operating force mechanism and parameters of a profile element in the additional operating force mechanism.Investigation method is a mathematical

  15. Biofuel and Hydrogen Influence for Operation Parameters of Spark Ignition Engine

    Directory of Open Access Journals (Sweden)

    Martynas Damaševičius

    2016-12-01

    Full Text Available Paper presents research of efficient and ecological parameters of gasoline engine working with biobuthanol (10% and 20% by volume and addi-tionaly supplying oxygen and hydrogen (HHO gas mixture (3.6 l/min, which was obtained from from water by electrolysis. Biobuthanol addition decreases rate of heat release, the combustion temperature and pressure are lower, which has an influence on lower nitrous oxide (NOx emission in exhaust gases. However, biobuthanol increases carbon monoxide (CO concentration. Biobuthanol fuel has a simplier molecular structure, therefore the concentration of HC in the exhaust gas is decreasing. Due to lower heating value of biobuthanol fuel and slower combustion process, the engine efficiency decreases and specific fuel consumptions increase. The change of engine energetical indicators due to biobuthanol, can be compensated with advanced ignition angle. Using experimental investigation, it was determined, that negative biobuthanol influence for the combustion process and engine efficient inicators can be compensated also by additional supplied HHO gas, in which the hydrogen element iprove fuel mixture com-bustion. Fuel combustion process analysis was carried out using AVL BOOST software. Experimental research and combustion process numerical simulation showed that using balanced biobuthanol and hydrogen addition, optimal efficient and ecological parameters could be achieved, when engine is working for petrol fuel typical optimal spark timing.

  16. Operational parameters estimation for a flexible manufacturing system. A case study

    Directory of Open Access Journals (Sweden)

    Florescu Adriana

    2017-01-01

    Full Text Available The complex structure of flexible manufacturing systems and rapid changes currently taking place with the evolution of the market and increase product diversity involves a detailed analysis of manufacturing processes. Manufacturing systems analysis can be done using methods based on analytical models and simulation. By applying these techniques one can view, analyze and forecast the performance of a dynamic system or of a new implemented system. Performance is one of the main factors affecting the design, development and configuration of any flexible manufacturing system. In this context, the present research will be directed to flexible manufacturing system structure analysis, to assess its performance, as well as simulating and validating these systems. It will generate and analyze key performance parameters, for the designed system by the use of specific software. Thus, it will study: the influence of the initial conditions or parameters on the behaviour of the flexible manufacturing system, the influence of the developing commands and system states on output or the influence of changes in the system structure on its behaviour.

  17. Non-linear parameter estimation for the LTP experiment: analysis of an operational exercise

    CERN Document Server

    Congedo, G; Ferraioli, L; Hueller, M; Vitale, S; Hewitson, M; Nofrarias, M; Monsky, A; Armano, M; Grynagier, A; Diaz-Aguilo, M; Plagnol, E; Rais, B

    2011-01-01

    The precursor ESA mission LISA-Pathfinder, to be flown in 2013, aims at demonstrating the feasibility of the free-fall, necessary for LISA, the upcoming space-born gravitational wave observatory. LISA Technology Package (LTP) is planned to carry out a number of experiments, whose main targets are to identify and measure the disturbances on each test-mass, in order to reach an unprecedented low-level residual force noise. To fulfill this plan, it is then necessary to correctly design, set-up and optimize the experiments to be performed on-flight and do a full system parameter estimation. Here we describe the progress on the non-linear analysis using the methods developed in the framework of the \\textit{LTPDA Toolbox}, an object-oriented MATLAB Data Analysis environment: the effort is to identify the critical parameters and remove the degeneracy by properly combining the results of different experiments coming from a closed-loop system like LTP.

  18. Denoising Algorithm Based on Generalized Fractional Integral Operator with Two Parameters

    Directory of Open Access Journals (Sweden)

    Hamid A. Jalab

    2012-01-01

    Full Text Available In this paper, a novel digital image denoising algorithm called generalized fractional integral filter is introduced based on the generalized Srivastava-Owa fractional integral operator. The structures of n×n fractional masks of this algorithm are constructed. The denoising performance is measured by employing experiments according to visual perception and PSNR values. The results demonstrate that apart from enhancing the quality of filtered image, the proposed algorithm also reserves the textures and edges present in the image. Experiments also prove that the improvements achieved are competent with the Gaussian smoothing filter.

  19. Plasma Shape and Current Density Profile Control in Advanced Tokamak Operating Scenarios

    Science.gov (United States)

    Shi, Wenyu

    The need for new sources of energy is expected to become a critical problem within the next few decades. Nuclear fusion has sufficient energy density to potentially supply the world population with its increasing energy demands. The tokamak is a magnetic confinement device used to achieve controlled fusion reactions. Experimental fusion technology has now reached a level where tokamaks are able to produce about as much energy as is expended in heating the fusion fuel. The next step towards the realization of a nuclear fusion tokamak power plant is ITER, which will be capable of exploring advanced tokamak (AT) modes, characterized by a high fusion gain and plasma stability. The extreme requirements of the advanced modes motivates researchers to improve the modeling of the plasma response as well as the design of feedback controllers. This dissertation focuses on several magnetic and kinetic control problems, including the plasma current, position and shape control, and data-driven and first-principles-driven modeling and control of plasma current density profile and the normalized plasma pressure ratio betaN. The plasma is confined within the vacuum vessel by an external electromagnetic field, produced primarily by toroidal and poloidal field coils. The outermost closed plasma surface or plasma boundary is referred to as the shape of the plasma. A central characteristic of AT plasma regimes is an extreme elongated shape. The equilibrium among the electromagnetic forces acting on an elongated plasma is unstable. Moreover, the tokamak performance is improved if the plasma is located in close proximity to the torus wall, which guarantees an efficient use of available volume. As a consequence, feedback control of the plasma position and shape is necessary. In this dissertation, an Hinfinity-based, multi-input-multi-output (MIMO) controller for the National Spherical Torus Experiment (NSTX) is developed, which is used to control the plasma position, shape, and X

  20. Correlation of Seminal Plasma Total Antioxidant Capacity and Malondialdehyde Levels With Sperm Parameters in Men With Idiopathic Infertility

    Directory of Open Access Journals (Sweden)

    Fazeli

    2016-01-01

    Full Text Available Background Oxidative stress is the result of an imbalance between the production and scavenging of reactive oxygen species (ROS. Recently, oxidative stress has been introduced as a major cause of male infertility. Objectives The aim of the present study was to determine the correlation between total antioxidant capacity (TAC and malondialdehyde (MDA as markers of oxidative stress in relation to idiopathic male infertility and sperm parameters. Patients and Methods This case control study was conducted using 35 men with idiopathic infertility and 34 men with proven fertility. Seminal plasma TAC and MDA were measured by ferric reducing ability of plasma (FRAP and thiobarbituric acid (TBA reaction methods, respectively. Results Seminal TAC levels were significantly lower and seminal MDA levels were significantly higher in men with idiopathic infertility than in fertile men (P < 0.0001 and P = 0.004, respectively. A positive correlation was shown between sperm motility, sperm morphology, and TAC levels in men with idiopathic infertility (P = 0.002 and P = 0.002, respectively. In addition, there was a correlation between sperm motility and TAC levels in fertile men (P = 0.005. There was no correlation between sperm count and TAC levels in either men with idiopathic infertility or in fertile men. Negative correlations were observed between MDA levels and sperm motility, morphology, and sperm count only in men with idiopathic infertility (P = 0.003, P = 0.001, and P = 0.006, respectively. Conclusions Our results show that oxidative stress could play an important role in male infertility as well as in sperm motility and sperm morphology.

  1. Parameter Optimization and Operating Strategy of a TEG System for Railway Vehicles

    Science.gov (United States)

    Heghmanns, A.; Wilbrecht, S.; Beitelschmidt, M.; Geradts, K.

    2016-03-01

    A thermoelectric generator (TEG) system demonstrator for diesel electric locomotives with the objective of reducing the mechanical load on the thermoelectric modules (TEM) is developed and constructed to validate a one-dimensional thermo-fluid flow simulation model. The model is in good agreement with the measurements and basis for the optimization of the TEG's geometry by a genetic multi objective algorithm. The best solution has a maximum power output of approx. 2.7 kW and does not exceed the maximum back pressure of the diesel engine nor the maximum TEM hot side temperature. To maximize the reduction of the fuel consumption, an operating strategy regarding the system power output for the TEG system is developed. Finally, the potential consumption reduction in passenger and freight traffic operating modes is estimated under realistic driving conditions by means of a power train and lateral dynamics model. The fuel savings are between 0.5% and 0.7%, depending on the driving style.

  2. Benchmarking environmental and operational parameters through eco-efficiency criteria for dairy farms.

    Science.gov (United States)

    Iribarren, Diego; Hospido, Almudena; Moreira, María Teresa; Feijoo, Gumersindo

    2011-04-15

    Life Cycle Assessment (LCA) is often used for the environmental evaluation of agri-food systems due to its holistic perspective. In particular, the assessment of milk production at farm level requires the evaluation of multiple dairy farms to guarantee the representativeness of the study when a regional perspective is adopted. This article shows the joint implementation of LCA and Data Envelopment Analysis (DEA) in order to avoid the formulation of an average farm, therefore preventing standard deviations associated with the use of average inventory data while attaining the characterization and benchmarking of the operational and environmental performance of dairy farms. Within this framework, 72 farms located in Galicia (NW Spain) were subject to an LCA+DEA study which led to identify those farms with an efficient operation. Furthermore, target input consumption levels were benchmarked for each inefficient farm, and the corresponding target environmental impacts were calculated so that eco-efficiency criteria were verified. Thus, average reductions of up to 38% were found for input consumption levels, leading to impact reductions above 20% for every environmental impact category. Finally, the economic savings arising from efficient farming practices were also estimated. Economic savings of up to 0.13€ per liter of raw milk were calculated, which means extra profits of up to 40% of the final raw milk price.

  3. Liver morphology and morphometry and plasma biochemical parameters of Wistar rats that received leaf infusion of Rudgea viburnoides Benth. (Rubiaceae

    Directory of Open Access Journals (Sweden)

    Juliana Castro Monteiro

    2009-04-01

    Full Text Available Rudgea viburnoides leaves are widely used in popular Brazilian medicine as a diuretic, antirheumatic, hypotensive and blood depurative tea. The present study was carried out to investigate the effects of this infusion on the liver and on the plasma biochemical parameters of Wistar rats. Two groups received the R. viburnoides leaf infusion at a daily dose of 10 or 20g dry-leaves/L water, during 40 days. The histopathological analysis did not show degenerated areas or infiltration of leucocytes. Hepatic morphometry showed accumulation of fat in the hepatocytes of the treated groups. There was no significant change in the plasma levels of urea, creatinin, uric acid, direct bilirubin, cholesterol, total proteins, albumin, gamma glutamyl tranferase (gamma-GT, alanine transaminase (ALT, aspartate transaminase (AST, chlorine, phosphate and calcium. A significant reduction in the plasma levels of triacylglycerol (TAG occurred in the group that received the higher dose.As folhas de Rudgea viburnoides Benth. são utilizadas na medicina popular como diuréticas, hipotensoras, anti-reumáticas, depurativas do sangue e em regimes de emagrecimento. O presente estudo foi delineado para avaliar o efeito da infusão das folhas de R. viburnoides nos parâmetros bioquímicos plasmáticos e na morfologia e morfometria hepática de ratos Wistar adultos. Dois grupos receberam a infusão das folhas, diariamente, nas dosagens de 10 e 20 g de folhas secas/L de água, durante 40 dias. O grupo controle recebeu a mesma quantidade de água. As análises histopatológicas não mostraram áreas degeneradas e infiltrados inflamatórios. A morfometria hepática mostrou acúmulo significativo de gordura nos hepatócitos dos animais tratados, principalmente no grupo que recebeu a maior dose da infusão (8,75% de gotículas lipídicas, comparado com 0,25% delas encontradas nos animais controles. Não foram observadas alterações nos níveis plasmáticos de uréia, creatinina,

  4. In vivo triglyceride synthesis in subcutaneous adipose tissue of humans correlates with plasma HDL parameters.

    Science.gov (United States)

    Tuvdendorj, Demidmaa; Munoz, Alejandro O; Ruiz-Barros, Viviana; Schwarz, Jean-Marc; Montalto, Giuseppe; Chandalia, Manisha; Sowers, Lawrence C; Rizzo, Manfredi; Murphy, Elizabeth J; Abate, Nicola

    2016-08-01

    Low concentrations of plasma HDL-C are associated with the development of atherosclerotic cardiovascular diseases and type 2 diabetes. Here we aimed to explore the relationship between the in vivo fractional synthesis of triglycerides (fTG) in subcutaneous (s.q.) abdominal adipose tissue (AT), HDL-C concentrations and HDL particle size composition in non-diabetic humans. The fTG in s.q. abdominal AT was measured in 16 non-diabetic volunteers (7 women, 9 men; Age: 49 ± 20 years; BMI: 31 ± 5 kg/m; Fasting Plasma Glucose: 90 ± 10 mg/dl) after (2)H2O labeling. HDL-C concentration and subclasses, large (L-HDL), intermediate (I-HDL) and small (S-HDL) were measured. Linear regression analyses demonstrated significant associations of fTG with plasma concentration of HDL-C (r = 0.625,p = 0.009) and percent contribution of L-HDL (r = 0.798,p HDL (r = -0.765,p HDL (r = -0.629, p = 0.009). When analyses were performed by gender, the associations remained significant in women (HDL-C: r = 0.822,p = 0.023; L-HDL: r = 0.892,p = 0.007; I-HDL: r = -0.927,p = 0.003) but not men. Our study demonstrated an in vivo association between subcutaneous abdominal adipose tissue lipid dynamics and HDL parameters in humans, but this was true for women not men. Positive association with L-HDL and negative with I-HDL suggest that subcutaneous abdominal adipose tissue lipid dynamics may play an important role in production of mature functional HDL particles. Further studies evaluating the mechanism responsible for these associations and the observed gender differences are important and warranted to identify potential novel targets of intervention to increase the production of atheroprotective subclasses of HDL-Cs and thus decreasing the risks of development of atherosclerotic conditions. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Blood serum and seminal plasma selenium, total antioxidant capacity and coenzyme q10 levels in relation to semen parameters in men with idiopathic infertility.

    Science.gov (United States)

    Eroglu, Mustafa; Sahin, Sadik; Durukan, Birol; Ozakpinar, Ozlem Bingol; Erdinc, Nese; Turkgeldi, Lale; Sofuoglu, Kenan; Karateke, Ates

    2014-06-01

    In this case-control study, we aimed to evaluate the serum and seminal plasma levels of Selenium (Se), total antioxidant capacity (TAC), and Coenzyme Q10 (CoQ-10) and determine their relationship with sperm concentration, motility, and morphology in men with idiopathic infertility. A total of 59 subjects were enrolled in the study. Forty four patients were diagnosed with idiopathic male infertility and had abnormal sperm parameters, and 15 subjects had normal sperm parameters with proven fertility. Serum Se, semen Se, and semen TAC levels were significantly different in the fertile and infertile groups (pspermatozoa concentration, motility, and morphology. Additionally, seminal plasma levels of TAC correlated positively with all these sperm parameters. On the other hand, seminal plasma levels of CoQ-10 correlated only with sperm morphology but not with concentration or motility. No relationship was observed between serum levels of TAC or serum levels of CoQ-10 and sperm parameters. In conclusion, serum and seminal plasma Se deficiency may be a prominent determinant of abnormal sperm parameters and idiopathic male infertility. Measurement of serum Se levels may help determine nutritional status and antioxidant capacity in infertile patients, which may help distinguish those patients who will benefit from supplementation therapy.

  6. A Fokker-Planck operator for the emission and absorption of electron plasma waves in a magnetized plasma

    Energy Technology Data Exchange (ETDEWEB)

    Ware, A.A.

    1993-03-01

    For slab geometry the perturbation of the electrostatic wake of a superthermal test electron in a magnetized plasma ({omega}{sub ce} {much_gt} {omega}{sub pe}) due to moderate magnetic shear is determined. Allowing for the spherical symmetry of the surfaces of constant phase to the rear of the test electron, the ``resonant`` field electrons causing the damping of the wave in a magnetic surface at a distance x from the test electron are those with parallel velocity {upsilon}{prime}{parallel} = {upsilon}{parallel} cos {beta} cos({beta} + {gamma}). Here {beta} is the angle between the emitted ray and B(0), {gamma} is the angle between B(0) and B(x) and {upsilon}{parallel} is the velocity of the test electron. As a result the damping in the WKB approximation for the wave emission is a function of both the angle of emission and {gamma}. A Fokker-Planck equation is derived for the rate of change of the electron distribution function (f) due to the emission and absorption of the waves under these conditions. f is assumed approximately Maxwellian for {upsilon}{parallel} > {upsilon}{sub T}.

  7. A Fokker-Planck operator for the emission and absorption of electron plasma waves in a magnetized plasma

    Energy Technology Data Exchange (ETDEWEB)

    Ware, A.A.

    1993-03-01

    For slab geometry the perturbation of the electrostatic wake of a superthermal test electron in a magnetized plasma ([omega][sub ce] [much gt] [omega][sub pe]) due to moderate magnetic shear is determined. Allowing for the spherical symmetry of the surfaces of constant phase to the rear of the test electron, the resonant'' field electrons causing the damping of the wave in a magnetic surface at a distance x from the test electron are those with parallel velocity [upsilon][prime][parallel] = [upsilon][parallel] cos [beta] cos([beta] + [gamma]). Here [beta] is the angle between the emitted ray and B(0), [gamma] is the angle between B(0) and B(x) and [upsilon][parallel] is the velocity of the test electron. As a result the damping in the WKB approximation for the wave emission is a function of both the angle of emission and [gamma]. A Fokker-Planck equation is derived for the rate of change of the electron distribution function (f) due to the emission and absorption of the waves under these conditions. f is assumed approximately Maxwellian for [upsilon][parallel] > [upsilon][sub T].

  8. Proposed parameters of specific rain attenuation prediction for Free Space Optics link operating in tropical region

    Science.gov (United States)

    Suriza, A. Z.; Md Rafiqul, Islam; Wajdi, A. K.; Naji, A. W.

    2013-03-01

    As the demand for higher and unlimited bandwidth for communication channel is increased, Free Space Optics (FSO) is a good alternative solution. As it is protocol transparent, easy to install, cost effective and have capabilities like fiber optics, its demand rises very fast. Weather condition, however is the limiting factor for FSO link. In the temperate region the major blockage for FSO link feasibility is fog. In the tropical region high rainfall rate is expected to be the major drawback of FSO link availability. Rain attenuation is the most significant to influence FSO link availability in tropical region. As for now the available k and α values are developed using data from temperate regions. Therefore, the objective of this paper is to propose new parameters for specific rain attenuation prediction model that represents tropical weather condition. The proposed values are derived from data measured in Malaysia and using methods recommended by ITU-R.

  9. Fluoride Removal from pretreated Photovoltaic Wastewater by Electrocoagulation: An Investigation of The Effect of Operational Parameters

    KAUST Repository

    Drouiche, Nadjib

    2012-03-20

    In this paper, application of electrocoagulation using common iron electrode to a simulated photovoltaic wastewater after precipitation with lime (Ca(OH)2) was investigated. Electrocoagulation process delivers the coagulant in situ as the sacrificial anode corrodes, while the simultaneous evolution of hydrogen at the cathode allows pollutant removal by flotation. Several working parameters, such as initial pH, applied potential and distance between the electrodes, were studied in an attempt to achieve higher fluoride removal efficiency. The optimum conditions for the process were identified as pH = 6, the distance between electrodes = 1 and an applied potential of 30 V. Furthermore fluoride removal is under the direct discharge standards.Results showed high effectivenessof the electrocoagulation method in removing fluoride from aqueous solutions.

  10. Operating and mathematical representation of resonances between flow parameters oscillations and structure vibrations of NPP

    Energy Technology Data Exchange (ETDEWEB)

    Proskuryakov, K.N.; Yang Shan Afshar, E.; Polyakov, N.I. [Nuclear Power Plant Department of Moscow Power Engineering Institute Technical Univ., Moscow (Russian Federation)

    2007-07-01

    The experimental data that have been obtained from the measurements of noise signals in primary circuit of NPP with reactor of WWER-1000 are presented. The causes of resonant interaction between Eigen-Frequencies of Oscillations of the Coolant Pressure (EFOCP) and structure vibrations are discussed. An application-oriented approach to the problem of identification of abnormal phenomena of thermal-hydraulic parameters is proposed. Logarithmic Decrement {delta} is determined. The bigger damping ratio {zeta} provides bigger {delta} and correspondingly smaller values of Q-factor and amplitude X(t)max. All experimental units intended for NPP severe accident investigation must satisfy to the NPP Q-factor criterion of similarity. (authors)

  11. Sensitivity of natural gas HCCI combustion to fuel and operating parameters using detailed kinetic modeling

    Energy Technology Data Exchange (ETDEWEB)

    Aceves, S; Dibble, R; Flowers, D; Smith, J R; Westbrook, C K

    1999-07-19

    This paper uses the HCT (Hydrodynamics, Chemistry and Transport) chemical kinetics code to analyze natural gas HCCI combustion in an engine. The HCT code has been modified to better represent the conditions existing inside an engine, including a wall heat transfer correlation. Combustion control and low power output per displacement remain as two of the biggest challenges to obtaining satisfactory performance out of an HCCI engine, and these are addressed in this paper. The paper considers the effect of natural gas composition on HCCI combustion, and then explores three control strategies for HCCI engines: DME (dimethyl ether) addition, intake heating and hot EGR addition. The results show that HCCI combustion is sensitive to natural gas composition, and an active control may be required to compensate for possible changes in composition. The three control strategies being considered have a significant effect in changing the combustion parameters for the engine, and should be able to control HCCI combustion.

  12. Bayesian derivation of plasma equilibrium distribution function for tokamak scenarios and the associated Landau collision operator

    CERN Document Server

    Di Troia, Claudio

    2015-01-01

    A class of parametric distribution functions has been proposed in [C.DiTroia, Plasma Physics and Controlled Fusion,54,2012] as equilibrium distribution functions (EDFs) for charged particles in fusion plasmas, representing supra-thermal particles in anisotropic equilibria for Neutral Beam Injection, Ion Cyclotron Heating scenarios. Moreover, the EDFs can also represent nearly isotropic equilibria for Slowing-Down $alpha$ particles and core thermal plasma populations. These EDFs depend on constants of motion (COMs). Assuming an axisymmetric system with no equilibrium electric field, the EDF depends on the toroidal canonical momentum $P_\\phi$, the kinetic energy $w$ and the magnetic moment \\mu. In the present work, the EDFs are obtained from first principles and general hypothesis. The derivation is probabilistic and makes use of the Bayes' Theorem. The bayesian argument allows us to describe how far from the prior probability distribution function (pdf), e.g. Maxwellian, the plasma is, based on the information...

  13. Bibliography of Documents Related to the Theory, Operation and Performance of Coaxial Plasma Guns

    Science.gov (United States)

    1988-09-01

    J. and Rodriguez- Trelles , "Recent Plasma Focus Research," in Proceedings of the Seventh International Conference on Plasma Physics and Controlled...pp. 512-525, Howard, R. (editor), Springer-Verlag, New York, NY, 1971. 29 Bostick, W. H., Nardi, V., Prior, W. J. and Rodriguez- Trelles , F., "On the...Physics, Vol. 8, Part 1, August 1972, pp. 7-20. Bostick, W. H., Nardi, V., Prior, W. and Rodriquez- Trelles , F., "Intensity Anisotropy and Fine Structure

  14. Development and Experimental Operation of a Flashboard Plasma Cathode Test Stand

    Science.gov (United States)

    2012-06-01

    Bixier, M. Krishnan, and D. Huet, “Density measurements in flash board plasmas for a magnetically confined plasma opening switch ,” in Pulsed Power...of HPMWs ........................................................ 3  C.  BACKGROUND OF CATHODES AND THEIR LIMITATIONS ............ 6  1.  Thermionic ...HPM system ...... 4  Figure 2.  Illustration of a thermionic cathode in an electron gun (From [11]) ....... 6  Figure 3.  Photoelectric emission from

  15. Initial Operation of the Miniaturized Inductively Heated Plasma Generator IPG6

    Science.gov (United States)

    Dropmann, Michael; Herdrich, Georg; Laufer, Rene; Koch, Helmut; Gomringer, Chris; Cook, Mike; Schmoke, Jimmy; Matthews, Lorin; Hyde, Truell

    2012-10-01

    In close collaboration between the Center for Astrophysics, Space Physics and Engineering Research (CASPER) at Baylor University, Texas, and the Institute of Space Systems (IRS) at the University of Stuttgart, Germany, two plasma wind tunnel facilities of similar type have been established using the inductively heated plasma source IPG6 which is based on proven IRS designs. The facility at Baylor University (IPG6-B) works at a frequency of 13.56 MHz and a maximum power of 15 kW. A vacuum pump of 160m^3/h in combination with a butterfly valve allows pressure control in a wide range. First experiments have been conducted with Air, O2 and N2 as working gases and volumetric flow rates of up to 14 L/min at pressures of a few 100 Pa, although pressures below 1 Pa are achievable at lower flow rates. The maximum tested electric power so far was 8 kW. Plasma powers and total pressures in the plasma jet have been obtained. In the near future the set up of additional diagnostics, the use of other gases (i.e. H2, He), and the integration of a dust particle accelerator are planned. The intended fields of research are basic investigation in thermo-chemistry and plasma radiation, space plasma environments and high heat fluxes e.g. in fusion devices or during atmospheric entry of spacecraft.

  16. A new scenario-based approach to damage detection using operational modal parameter estimates

    Science.gov (United States)

    Hansen, J. B.; Brincker, R.; López-Aenlle, M.; Overgaard, C. F.; Kloborg, K.

    2017-09-01

    In this paper a vibration-based damage localization and quantification method, based on natural frequencies and mode shapes, is presented. The proposed technique is inspired by a damage assessment methodology based solely on the sensitivity of mass-normalized experimental determined mode shapes. The present method differs by being based on modal data extracted by means of Operational Modal Analysis (OMA) combined with a reasonable Finite Element (FE) representation of the test structure and implemented in a scenario-based framework. Besides a review of the basic methodology this paper addresses fundamental theoretical as well as practical considerations which are crucial to the applicability of a given vibration-based damage assessment configuration. Lastly, the technique is demonstrated on an experimental test case using automated OMA. Both the numerical study as well as the experimental test case presented in this paper are restricted to perturbations concerning mass change.

  17. The comparison of solar water heating system operation parameters calculated using traditional method and dynamic simulations

    Directory of Open Access Journals (Sweden)

    Sornek Krzysztof

    2016-01-01

    Full Text Available The proper design of renewable energy based systems is really important to provide their efficient and safe operation. The aim of this paper is to compare the results obtained during traditional static calculations, with the results of dynamic simulations. For this reason, simulations of solar water heating (SWH system, designed for a typical residential building, were conducted in the TRNSYS (Transient System Simulation Tool. Carried out calculations allowed to determine the heat generation in the discussed system as well as to estimate the efficiency of considered installation. Obtained results were compared with the results from other available tool based on the static calculations. It may be concluded, that using dynamic simulations at the designing stage of renewable energy based systems may help to avoid many exploitation problems (including low efficiency, overheating etc. and allows to provide safe exploitation of such installations.

  18. Effects of Design/Operating Parameters and Physical Properties on Slag Thickness and Heat Transfer during Coal Gasification

    Directory of Open Access Journals (Sweden)

    Insoo Ye

    2015-04-01

    Full Text Available The behaviors of the slag layers formed by the deposition of molten ash onto the wall are important for the operation of entrained coal gasifiers. In this study, the effects of design/operation parameters and slag properties on the slag behaviors were assessed in a commercial coal gasifier using numerical modeling. The parameters influenced the slag behaviors through mechanisms interrelated to the heat transfer, temperature, velocity, and viscosity of the slag layers. The velocity profile of the liquid slag was less sensitive to the variations in the parameters. Therefore, the change in the liquid slag thickness was typically smaller than that of the solid slag. The gas temperature was the most influential factor, because of its dominant effect on the radiative heat transfer to the slag layer. The solid slag thickness exponentially increased with higher gas temperatures. The influence of the ash deposition rate was diminished by the high-velocity region developed near the liquid slag surface. The slag viscosity significantly influenced the solid slag thickness through the corresponding changes in the critical temperature and the temperature gradient (heat flux. For the bottom cone of the gasifier, steeper angles were favorable in reducing the thickness of the slag layers.

  19. The effects of DRIE operational parameters on vertically aligned micropillar arrays

    Science.gov (United States)

    Miller, Kane; Li, Mingxiao; Walsh, Kevin M.; Fu, Xiao-An

    2013-03-01

    Vertically aligned silicon micropillar arrays have been created by deep reactive ion etching (DRIE) and used for a number of microfabricated devices including microfluidic devices, micropreconcentrators and photovoltaic cells. This paper delineates an experimental design performed on the Bosch process of DRIE of micropillar arrays. The arrays are fabricated with direct-write optical lithography without photomask, and the effects of DRIE process parameters, including etch cycle time, passivation cycle time, platen power and coil power on profile angle, scallop depth and scallop peak-to-peak distance are studied by statistical design of experiments. Scanning electron microscope images are used for measuring the resultant profile angles and characterizing the scalloping effect on the pillar sidewalls. The experimental results indicate the effects of the determining factors, etch cycle time, passivation cycle time and platen power, on the micropillar profile angles and scallop depths. An optimized DRIE process recipe for creating nearly 90° and smooth surface (invisible scalloping) has been obtained as a result of the statistical design of experiments.

  20. Synthesis of TiO2 supported on activated carbon by MOCVD:operation parameters study

    Institute of Scientific and Technical Information of China (English)

    张兴旺; 周明华; 雷乐成; 徐甦

    2004-01-01

    A novel metallo-organic chemical vapor deposition (MOCVD) technique has been applied to the preparation of the photocatalytic titanium dioxide supported on activated carbon. The effects of various condition parameters such as carrier gas flow rate, source temperature and deposition temperature on the deposition rate were investigated. The maximum deposition rate of 8.2 mg/(g.h) was obtained under conditions of carrier gas flow rate of 400 ml/min, source temperature of 423 K and deposition temperature of 913 K. The deposition rate followed Arrhenius behavior at temperature of 753 K to 913 K, corresponding to activation energy Ea of 51.09 kJ/mol. TiO2 existed only in anatase phase when the deposition temperature was 773 K to 973 K. With increase of deposition temperature from 1073 K to 1273 K, the rutile content sharply increased from 7% to 70%. It was found that a deposition temperature of 773 K and a higher source temperature of 448 K resulted in finely dispersed TiO2 particles, which were mainly in the range of 10-20 nm.

  1. Relationships between tissue properties and operational parameters of a dental handpiece during simulated cavity preparation.

    Science.gov (United States)

    Sun, Hongyan; Lau, Andrew; Heo, Young C; Lin, Lianshan; Delong, Ralph; Fok, Alex

    2013-01-01

    A preliminary study was conducted on the development of an intelligent dental handpiece with functionality to detect subtle changes in mechanical properties of tooth tissue during milling. Such equipment would be able to adopt changes in cutting parameters and make real-time measurements to avoid tooth tissue damage caused by overexertion and overextension of the cutting tool. A modified dental handpiece, instrumented with strain gauges, microphone, displacement sensor, and air pressure sensor, was mounted to a linear movement table and used to mill three to four cavities in >50 bovine teeth. Extracted sound frequency and density were analyzed along with force, air pressure, and displacement for correlations and trends. Experimental results showed a high correlation (coefficient close to 0.7) between the feed force, the rotational frequency, and the averaged gray scale. These results could form the basis of a feedback control system to improve the safety of dental cutting procedures. This article is written in memory of Dr Hongyan Sun, who passed away in 2011 at a young age of 37.

  2. Influence of operating parameters on cake formation in pilot scale pulse-jet bag filter.

    Science.gov (United States)

    Saleem, Mahmood; Krammer, Gernot; Khan, Rafi Ullah; Tahir, M Suleman

    2012-07-01

    Bag filters are commonly used for fine particles removal in off-gas purification. There dust laden gas pervades through permeable filter media starting at a lower pressure drop limit leaving dust (called filter cake) on the filter media. The filter cakeformation is influenced by many factors including filtration velocity, dust concentration, pressure drop limits, and filter media resistance. Effect of the stated parameters is investigated experimentally in a pilot scale pulse-jet bag filter test facility where lime stone dust is separated from air at ambient conditions. Results reveal that filtration velocity significantly affects filter pressure drop as well as cake properties; cake density and specific cake resistance. Cake density is slightly affected by dust concentration. Specific resistance of filter cake increases with velocity, slightly affected by dust concentration, changes inversely with the upper pressure drop limit and decreases over a prolonged use (aging). Specific resistance of filter media is independent of upper pressure drop limit and increases linearly over a prolonged use.

  3. Synthesis of TiO2 supported on activated carbon by MOCVD: operation parameters study

    Institute of Scientific and Technical Information of China (English)

    张兴旺; 周明华; 雷乐成; 徐甦

    2004-01-01

    A novel metallo-organic chemical vapor deposition (MOCVD) technique has been applied to the preparation of the photocatalytic titanium dioxide supported on activated carbon. The effects of various condition parameters such as carrier gas flow rate, source temperature and deposition temperature on the deposition rate were investigated. The maximum deposition rate of 8.2 mg/(g.h) was obtained under conditions of carrier gas flow rate of 400 ml/min, source temperature of 423 K and deposition temperature of 913 K. The deposition rate followed Arrhenius behavior at temperature of 753 K to 913 K, corresponding to activation energy Ea of 51.09 kJ/mol. TiO2 existed only in anatase phase when the deposition temperature was 773 K to 973 K. With increase of deposition temperature from 1073 K to 1273 K, the rutile content sharply increased from 7% to 70%. It was found that a deposition temperature of 773 K and a higher source temperature of 448 K resulted in finely dispersed TiO2 particles, which were mainly in the range of 10-20 nm.

  4. Methylparaben removal using heterogeneous photocatalysis: effect of operational parameters and mineralization/biodegradability studies.

    Science.gov (United States)

    Zúñiga-Benítez, Henry; Peñuela, Gustavo A

    2017-03-01

    Methylparaben (MePB) is an organic compound employed mainly in the manufacture of different personal care products. However, it has been recently listed as a potential endocrine disrupter chemical. Therefore, the main objective of this work was to evaluate the degradation of MePB in aqueous solutions using heterogeneous photocatalysis with TiO2 and hydrogen peroxide. In this way, effects of pH and the initial concentrations of catalyst, H2O2, and pollutant on treatment were analyzed. A face centered, central composite design was used for determination of the influence of each parameter in the process and the conditions under which the pollutant suffers the highest rates of degradation were selected. In general, results indicate that combination TiO2/H2O2/light irradiation leads to ∼90 % of substrate removal after 30 min of reaction and that hydroxyl free radicals are the main specie responsible for organic matter elimination. Finally, in terms of mineralization and biodegradability, experimental results indicated that part of the organic matter was transformed into CO2 and water and the photo-treatment promoted an increase in samples biodegradability.

  5. Process parameters for operating 1-butanol gas stripping in a fermentor.

    Science.gov (United States)

    Liao, Ying-Chen; Lu, Kuan-Ming; Li, Si-Yu

    2014-11-01

    In this study, effects of the agitation speed, the flow rate, and type of non-polar gases on the performance of gas stripping was systematically investigated. Macroscopically, the stripping rate of butanol is linearly proportional to the concentration of butanol in the feed solution. Nevertheless, a decrease in butanol selectivity was observed with the increasing butanol concentrations up to 0.01 g/cm(3). This can be attributed to the thermodynamics reason that with increasing butanol concentrations in the feed, more stripping gas will dissolve in the feed solution that decrease the activity of butanol for mass transfer from liquids to gas bubbles. This can be supported by the use of highly soluble gas of carbon dioxide as the stripping gas where the Ksa dropped 48% compared to the nitrogen stripping. By the parameter sensitivity analysis, it has been shown that the dominant variable is the flow rate. The best strategy of maximizing the performance of 1-butanol gas stripping at a given flow rate is to bubble the gases at a high superficial velocity, which leads to a less resistance on the liquid side for mass transfer.

  6. APPLICATION OF TAGUCHI AND ANOVA IN OPTIMIZATION OF PROCESS PARAMETERS OF LAPPING OPERATION FOR CAST IRON

    Directory of Open Access Journals (Sweden)

    P.R. Parate

    2013-06-01

    Full Text Available Lapping appears like a miraculous process, because it can produce surfaces that are perfectly flat, perfectly round, perfectly smooth, perfectly sharp, or perfectly accurate. Under the correct circumstances, it can impart or improve precise geometry (flatness, roundness, etc., improve surface finish, improve surface quality, achieve high dimensional accuracy (length, diameter, etc., improve angular accuracy (worm gears, couplings, etc., improve fit, and above all, sharpen the tools. This paper presents research on calculating the material removal rate for a machining component by the lapping process. The cast iron sample with an outer diameter of 50 mm and an inner diameter of 45 mm was tested on a single plate tabletop lapping machine. Experiments based on design of experiments were conducted by varying lapping load, lapping time, paste concentration, lapping fluid, and by using different types of abrasives. The Taguchi statistical method has been used in this work. Optimum machining parameters for material removal rate are estimated and verified with experimental results and are found to be in good agreement. The confirmation test exhibits high material removal rate by using Al2O3 abrasive particles together with oil as a carrier fluid under the impression of high load. Further material removal rate increases with an increase in lapping load and time.

  7. Adsorption removal of tannic acid from aqueous solution by polyaniline: Analysis of operating parameters and mechanism.

    Science.gov (United States)

    Sun, Chencheng; Xiong, Bowen; Pan, Yang; Cui, Hao

    2017-02-01

    Polyaniline (PANI) prepared by chemical oxidation was studied for adsorption removal of tannic acid (TA) from aqueous solution. Batch adsorption studies were carried out under different adsorbent dosages, pH, ionic strength, initial TA concentration and coexisting anions. Solution pH had an important impact on TA adsorption onto PANI with optimal removal in the pH range of 8-11. TA adsorption on PANI at three ionic strength levels (0.02, 0.2 and 2molL(-1) NaCl) could be well described by Langmuir model (monolayer adsorption process) and the maximum adsorption capacity was 230, 223 and 1023mgg(-1), respectively. Kinetic data showed that TA adsorption on PANI fitted well with pseudo-second-order model (controlled by chemical process). Among the coexisting anions tested, PO4(3-) significantly inhibited TA adsorption due to the enhancement of repulsive interaction. Continuous flow adsorption studies indicated good flexibility and adaptability of the PANI adsorbent under different flow rates and influent TA concentrations. The mechanism controlling TA adsorption onto PANI under different operating conditions was analyzed with the combination of electrostatic interactions, hydrogen bonding, π-π interactions and Van der Waals interactions. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Recovery of proteins from wastewater of tannery beamhouse operations: influence on the main pollution parameters.

    Science.gov (United States)

    Marsal, A; Hernández, E; Cuadros, S; Puig, R; Bautista, E; Font, J

    2010-01-01

    The recovery of proteins from effluents of beamhouse operations in a hair-pulping process of hides is proposed. Precipitation with sulphuric acid at the isoelectric pH was chosen for protein recovery. The precipitates were characterized in order to study their potential uses. Apart from the protein nitrogen, the precipitate also contained a considerable content of fats resulting from the co-precipitation of natural fat of the hide in the wastewaters. The precipitation of the protein fraction resulted in a reduction of 80-85% of COD, whereas the protein content decreased 68-78%. This diminution of the contamination load led to a notable reduction of the tax on wastewater. The content of protein material in the precipitate varied from 15 to 44%. As expected, the protein in the precipitate did not result from the collagen decomposition of the hide but from soluble proteins such as albumin and globulin and remains of keratin. The precipitates obtained met the maximum limits of heavy metals according to legislation on organic fertilizers. The potential uses of the protein fraction recovered from tannery wastewaters are currently being investigated.

  9. DRINKING WATER FROM DESALINATION OF SEAWATER: OPTIMIZATION OF REVERSE OSMOSIS SYSTEM OPERATING PARAMETERS

    Directory of Open Access Journals (Sweden)

    MARWAN M. SHAMEL

    2006-12-01

    Full Text Available This paper reports on the use of pilot scale membrane separation system coupled with another pilot scale plate heat exchanger to investigate the possibilities of sweetening seawater from Telok Kalong Beach, Terengganu, Malaysia. Reverse osmosis (RO membrane of a surface area of 0.5 m2 was used during the experimental runs. Experiments were conducted at different transmembrane pressures (TMP ranged from 40 to 55 bars, operation temperature ranged from 35 to 45oC, feed concentration (TDS ranged from 34900 to 52500 ppm and cross flow velocities ranged from 1.4 to 2.1 m/s. The result show that the flux values increased linearly with TMP as well as sodium ion rejection. Permeate flux values increased proportionally with the temperature and the later effect was more significant at high pressures. The temperature changing has also influenced the rejection of sodium ion. The minerals content especially NaCl and total dissolved solid (TDS in the drinking water produced in this research are conforming to the standards of World Health Organization (WHO.

  10. Influence of operating parameters on the performance of magnetic seeding flocculation.

    Science.gov (United States)

    Chen, Yiqing; Luo, Man; Cai, Wangfeng

    2016-02-01

    In the present study, magnetic seeding flocculation was applied to remove copper (200 mg/L) and turbidity (180 mg/L) from simulated microetch copper waste. Fe3O4 particles (40 to 1600 mesh) were used as magnetic seeds. Poly-aluminum chloride (PAC) and anionic polyacrylamide (PAM) were added as coagulant and flocculant, respectively. The effect of operating factors, such as the dosages of the coagulant and flocculant, initial pH of the wastewater, and dosage and size of the magnetic seeds, on copper and turbidity removal was systematically investigated. In addition, settling speed, floc-size distribution, and volume of sludge were measured with and without the addition of magnetic seeds to compare the efficiency of magnetic seeding to that of traditional flocculation. The results indicated that the highest settling speed, the largest floc size, and the smallest volume of sludge were obtained simultaneously when the dosage and size of magnetic seeds were 2.0 g/L and 300–400 mesh, respectively. High removal efficiencies of 98.53 and 94.72 % for copper and turbidity, respectively, were also achieved under this condition; values that are 4.11 and 0.61 % higher, respectively, than those found in traditional flocculation. The high performance might be attributed to efficient collision of particles and slightly moderate vortex centrifugal force of inertia among the magnetic seeds, which could produce larger magnetic flocs with lower moisture.

  11. Effects of operating parameters on efficiency of lead removal by complexation-microfiltration process

    Directory of Open Access Journals (Sweden)

    Trivunac Katarina V.

    2012-01-01

    Full Text Available Majority of lead content found in the environment is the result of human activities. Heavy metals can be hazardous because they tend to bioaccumulate. Complexation-microfiltration process for the removal of Pb(II ions was studied. The aim of microfiltration of the model wastewater containing heavy metal ions was finding an optimum ratio between the concentrations of the complexing agent and metal, and determining the most favorable pH value. The microfiltration experiments were carried out in a stirred dead-end cell. Diethylaminoethyl cellulose (DEAE 23 was selected as the complexing agent. Versapor membranes were used to separate formed polymer-metal complex. The concentration of heavy metal ions after microfiltration in aqueous solution was determined using the atomic absorption spectroscopy (AAS. Effects on the amount of complexing agent, concentration of metal ion, pH value and operating pressure on the flux, J, and rejection coefficient, R, were investigated. Experimental results indicate that the pH of the solution has considerable influence on the rejection coefficient. An increase in pH and the amount of complexing agents enabled us to obtain very high retention coefficient (99%.

  12. Optimization of digestion parameters for analysing the total sulphur of mine tailings by inductively coupled plasma optical emission spectrometry.

    Science.gov (United States)

    Alam, Raquibul; Shang, Julie Q; Cheng, Xiangrong

    2012-05-01

    The oxidation of sulphidic mine tailings and consequent acid generation poses challenges for the environment. Accurate and precise analysis of sulphur content is necessary for impact assessment and management of mine tailings. Here, the authors aim at developing a rapid and easy digestion procedure, which may analyse and measure the total amount of sulphur in mine tailings by using inductively coupled plasma. For evaluating effects of several variables, the researchers used a univariate (analysis of variance (ANOVA)) strategy and considered factors such as composition of the acid mixture, heating time, and refluxing device to optimize the performance. To do the experiment, the researchers have used two certified reference materials (KZK-1 and RTS-2) and samples of tailings from Musselwhite mine. ANOVA result shows that heating time is the most influencing factor on acid digestion of the reference materials whereas in case of a digestion of tailings sample, hydrochloric acid proved to be the most significant parameter. Satisfactory results between the measured and referenced values are found for all experiments. It is found that the aqua regia (1 ml HNO(3) + 3 ml HCl) digestion of 0.1 g of samples after only 40 min of heating at 95°C produced fast, safe, and accurate analytical results with a recovery of 97% for the selected reference materials.

  13. Effect of technique parameters on characteristics of hydrogen-free DLC films deposited by surface wave-sustained plasma

    Science.gov (United States)

    Xu, Junqi; Kousaka, Hiroyuki; Umehara, Noritsugu; Diao, Dongfeng

    2006-01-01

    Hydrogen-free diamond-like carbon (DLC) films were deposited by a new-type surface wave-sustained plasma physical vapor deposition (SWP-PVD) system under various technique conditions. Electron density was measured by a Langmuir probe, while the film thickness and hardness were characterized using a surface profilometer and a nanoindenter, respectively. Surface morphology was investigated by an atomic force microscope (AFM). It was found that the electron density and deposition rate increased following the increase in microwave power, target voltage, or gas pressure. The typical electron density and deposition rate were about 1.87-2.04×10 11 cm -3 and 1.61-14.32 nm/min respectively. AFM images indicated that the grains of films changes as the technique parameters vary. The optical constants, refractive index n and extinction coefficient k, were obtained using an optical ellipsometry. With the increase in microwave power from 150 to 270 W, the extinction coefficient of DLC films increased from 0.05 to 0.27 while the refractive index decreased from 2.31 to 2.18.

  14. Jet quenching parameter of quark-gluon plasma in strong magnetic field: perturbative QCD and AdS/CFT correspondence

    CERN Document Server

    Li, Shiyong; Yee, Ho-Ung

    2016-01-01

    We compute the jet quenching parameter $\\hat q$ of QCD plasma in the presence of strong magnetic field in both weakly and strongly coupled regimes. In weakly coupled regime, we compute $\\hat q$ in perturbative QCD at complete leading order (that is, leading log as well as the constant under the log) in QCD coupling constant $\\alpha_s$, assuming the hierarchy of scales $\\alpha_s eB\\ll T^2\\ll eB$. We consider two cases of jet orientations with respect to the magnetic field: 1) the case of jet moving parallel to the magnetic field, 2) the case jet moving perpendicular to the magnetic field. In the former case, we find $\\hat q\\sim \\alpha_s^2 (eB)T\\log(1/\\alpha_s)$, while in the latter we have $\\hat q\\sim \\alpha_s^2 (eB)T\\log(T^2/\\alpha_seB)$. In both cases, this leading order result arises from the scatterings with thermally populated lowest Landau level quarks. In strongly coupled regime described by AdS/CFT correspondence, we find $\\hat q\\sim \\sqrt{\\lambda}(eB)T$ or $\\hat q\\sim\\sqrt{\\lambda}\\sqrt{eB}T^2$ in the...

  15. Optical characteristics and parameters of gas-discharge plasma in a mixture of mercury dibromide vapor with argon

    Energy Technology Data Exchange (ETDEWEB)

    Malinina, A. A., E-mail: alexandr-malinin@rambler.ru; Malinin, A. N. [Uzhhorod National University (Ukraine)

    2015-03-15

    Results are presented from studies of the optical characteristics and parameters of the plasma of a dielectric barrier discharge in a mixture of mercury dibromide vapor with argon—the working medium of an exciplex gas-discharge emitter. It is established that the partial pressures of mercury dibromide vapor and argon at which the average and pulsed emission intensities in the blue—green spectral region (λ{sub max} = 502 nm) reach their maximum values are 0.6 and 114.4 kPa, respectively. The electron energy distribution function, the transport characteristics, the specific power spent on the processes involving electrons, the electron density and temperature, and the rate constants for the processes of elastic and inelastic electron scattering from the molecules and atoms of the working mixture are determined by numerical simulation, and their dependences on the reduced electric field strength are analyzed. The rate constant of the process leading to the formation of exciplex mercury monobromide molecules for a reduced electric field of E/N = 20 Td, at which the maximum emission intensity in the blue—green spectral region was observed in this experiment, is found to be 8.1 × 10{sup −15} m{sup 3}/s.

  16. Effect of deposition parameters on structural and mechanical properties of niobium nitride synthesized by plasma focus device

    Science.gov (United States)

    Siddiqui, Jamil; Hussain, Tousif; Ahmad, Riaz; Khalid, Nida

    2015-06-01

    Effects of deposition angle and axial distance on the structural and mechanical properties of niobium nitride synthesized by a dense plasma focus (DPF) system are studied. The x-ray diffraction (XRD) confirms that the deposition parameters affect the growth of multi-phase niobium nitride. Scanning electron microscopy (SEM) shows the granular surface morphology with strong thermally assisted coagulation effects observed at the 5-cm axial distance. The non-porous granular morphology observed at the 9-cm distance along the anode axis is different from those observed at deposition angles of 10° and 20°. Energy dispersive x-ray (EDX) spectroscopy reveals the maximum nitrogen content at the shortest (5 cm) axial position. Atomic force microscopy (AFM) exhibits that the roughness of coated films varies for coatings synthesized at different axial and angular positions, and the Vickers micro-hardness test shows that a maximum hardness value is (08.44 ± 0.01) GPa for niobium nitride synthesized at 5-cm axial distance, which is about 500% more than that of a virgin sample. Project supported by the HEC, Pakistan.

  17. The Effect of Processing Parameters on the Performance of Spark Plasma Sintered cBN-WC-Co Composites

    Science.gov (United States)

    Mao, Cong; Zhang, Mingjun; Zhang, Jian; Tang, Kun; Gan, Hangyu; Zhang, Gaofeng

    2015-12-01

    Cubic boron nitride (cBN) particles were mixed into superfine tungsten carbide (WC), and then cBN-WC-cobalt (Co) composites were prepared using spark plasma sintering method. The influence of the processing parameters on the microstructures and the mechanical properties of the cBN-WC-Co composites were investigated. The results indicated that the cBN particles arranged uniformly and had an excellent adhesion with WC matrix. There was no evidence of phase transformation from cBN to hBN. With the increasing of the sintering temperature, the liquid-phase Co was increased and entered the micro-pores between WC and cBN particles easily. Correspondingly, the density, the flexural strength, and the hardness of the cBN-WC-Co composites also increased. With the further increasing of the sintering temperature, WC grains grew leading to the reduction of the hardness. Therefore, the hardness of the samples increased to a maximum value of 2978 HV at 1250 °C, and then decreased with the sintering temperature. The experimental results also showed that the density, the flexural strength, and the hardness of cBN-WC-Co composites increased with the holding time, whereas the hardness presented a decreasing tendency when the holding time exceeded 7 min.

  18. Possibilities And Influencing Parameters For The Early Detection Of Sheet Metal Failure In Press Shop Operations

    Science.gov (United States)

    Gerlach, Jörg; Kessler, Lutz; Paul, Udo; Rösen, Hartwig

    2007-05-01

    The concept of forming limit curves (FLC) is widely used in industrial practice. The required data should be delivered for typical material properties (measured on coils with properties in a range of +/- of the standard deviation from the mean production values) by the material suppliers. In particular it should be noted that its use for the validation of forming robustness providing forming limit curves for the variety of scattering in the mechanical properties is impossible. Therefore a forecast of the expected limit strains without expensive cost and time-consuming experiments is necessary. In the paper the quality of a regression analysis for determining forming limit curves based on tensile test results is presented and discussed. Owing to the specific definition of limit strains with FLCs following linear strain paths, the significance of this failure definition is limited. To consider nonlinear strain path effects, different methods are given in literature. One simple method is the concept of limit stresses. It should be noted that the determined value of the critical stress is dependent on the extrapolation of the tensile test curve. When the yield curve extrapolation is very similar to an exponential function, the definition of the critical stress value is very complicated due to the low slope of the hardening function at large strains. A new method to determine general failure behavior in sheet metal forming is the common use and interpretation of three criteria: onset on material instability (comparable with FLC concept), value of critical shear fracture and the value of ductile fracture. This method seems to be particularly successful for newly developed high strength steel grades in connection with more complex strain paths for some specific material elements. Nevertheless the identification of the different failure material parameters or functions will increase and the user has to learn with the interpretation of the numerical results.

  19. Effect of some operational parameters on the arsenic removal by electrocoagulation using iron electrodes.

    Science.gov (United States)

    Can, Berrin Zeliha; Boncukcuoglu, Recep; Yilmaz, Alper Erdem; Fil, Baybars Ali

    2014-01-01

    Arsenic contamination of drinking water is a global problem that will likely become more apparent in future years as scientists and engineers measure the true extent of the problem. Arsenic poisoning is preventable though as there are several methods for easily removing even trace amounts of arsenic from drinking water. In the present study, electrocoagulation was evaluated as a treatment technology for arsenic removal from aqueous solutions. The effects of parameters such as initial pH, current density, initial concentration, supporting electrolyte type and stirring speed on removal efficiency were investigated. It has been observed that initial pH was highly effective on the arsenic removal efficiency. The highest removal efficiency was observed at initial pH = 4. The obtained experimental results showed that the efficiency of arsenic removal increased with increasing current density and decreased with increasing arsenic concentration in the solution. Supporting electrolyte had not significant effects on removal, adding supporting electrolyte decreased energy consumption. The effect of stirring speed on removal efficiency was investigated and the best removal efficiency was at the 150 rpm. Under the optimum conditions of initial pH 4, current density of 0.54 mA/cm(2), stirring speed of 150 rpm, electrolysis time of 30 minutes, removal was obtained as 99.50%. Energy consumption in the above conditions was calculated as 0.33 kWh/m(3). Electrocoagulation with iron electrodes was able to bring down 50 mg/L arsenic concentration to less than 10 μg/L at the end of electrolysis time of 45 minutes with low electrical energy consumption as 0.52 kWh/m(3).

  20. Use of natural clays as sorbent materials for rare earth ions: Materials characterization and set up of the operative parameters.

    Science.gov (United States)

    Iannicelli-Zubiani, Elena Maria; Cristiani, Cinzia; Dotelli, Giovanni; Gallo Stampino, Paola; Pelosato, Renato; Mesto, Ernesto; Schingaro, Emanuela; Lacalamita, Maria

    2015-12-01

    Two mineral clays of the montmorillonite group were tested as sorbents for the removal of Rare Earths (REs) from liquid solutions. Lanthanum and neodymium model solutions were used to perform uptake tests in order to: (a) verify the clays sorption capability, (b) investigate the sorption mechanisms and (c) optimize the experimental parameters, such as contact time and pH. The desorption was also studied, in order to evaluate the feasibility of REs recovery from waters. The adsorption-desorption procedure with the optimized parameters was also tested on a leaching solution obtained by dissolution of a dismantled NdFeB magnet of a hard-disk. The clays were fully characterized after REs adsorption and desorption by means of X-ray powder diffraction (XRPD) and X-ray photoelectron spectroscopy (XPS); the liquid phase was characterized via Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES) analyses. The experimental results show that both clays are able to capture and release La and Nd ions, with an ion exchange mechanism. The best total efficiency (capture ≈ 50%, release ≈ 70%) is obtained when the uptake and release processes are performed at pH=5 and pH=1 respectively; in real leached scrap solutions, the uptake is around 40% but release efficiency is strongly decreased passing from a mono-ion system to a real system (from 80% to 5%). Furthermore, a strong matrix effect is found, with the matrix largely affecting both the uptake and the release of neodymium.

  1. Prediction and Optimization Approaches for Modeling and Selection of Optimum Machining Parameters in CNC down Milling Operation

    Directory of Open Access Journals (Sweden)

    Asaad A. Abdullah

    2014-04-01

    Full Text Available In this study, we suggested intelligent approach to predict and optimize the cutting parameters when down milling of 45# steel material with cutting tool PTHK- (Ø10*20C*10D*75L -4F-1.0R under dry condition. The experiments were performed statistically according to four factors with three levels in Taguchi experimental design method. Adaptive Neuro-fuzzy inference system is utilized to establish the relationship between the inputs and output parameter exploiting the Taguchi orthogonal array L27. The Particle Swarm Optimized-Adaptive Neuro-Fuzzy Inference System (PSOANFIS is suggested to select the best cutting parameters providing the lower surface through from the experimental data using ANFIS models to predict objective functions. The PSOANFIS optimization approach that improves the surface quality from 0.212 to 0.202, as well as the cutting time is also reduced from 7.5 to 4.78 sec according to machining parameters before and after optimization process. From these results, it can be readily achieved that the advanced study is trusted and suitable for solving other problems encountered in metal cutting operations and the same surface roughness.

  2. High-Precision Lunar Ranging and Gravitational Parameter Estimation With the Apache Point Observatory Lunar Laser-ranging Operation

    Science.gov (United States)

    Johnson, Nathan H.

    This dissertation is concerned with several problems of instrumentation and data analysis encountered by the Apache Point Observatory Lunar Laser-ranging Operation. Chapter 2 considers crosstalk between elements of a single-photon avalanche photodiode detector. Experimental and analytic methods were developed to determine crosstalk rates, and empirical findings are presented. Chapter 3 details electronics developments that have improved the quality of data collected by detectors of the same type. Chapter 4 explores the challenges of estimating gravitational parameters on the basis of ranging data collected by this and other experiments and presents resampling techniques for the derivation of standard errors for estimates of such parameters determined by the Planetary Ephemeris Program (PEP), a solar-system model and data-fitting code. Possible directions for future work are discussed in Chapter 5. A manual of instructions for working with PEP is presented as an appendix.

  3. Effects of ion source operating parameters on direct analysis in real time of 18 active components from traditional Chinese medicine.

    Science.gov (United States)

    Wang, Lu; Zeng, Shanshan; Qu, Haibin

    2016-03-20

    Direct analysis in real time mass spectrometry (DART-MS) provides a new analytical method for traditional Chinese medicine (TCM). The present study investigated the effects of key ion source operating parameters on DART-MS analysis of various TCM active components. A total of 18 active components, including phenylpropanoids, alkaloids, saponins, flavones, volatile oils, and glycosides, were examined. For each substance, the peak area and signal-to-noise of its characteristic ions under different reagent gases and heater temperatures were compared. Based on the comparison, the relationships among chemical structures, ion source parameters and instrument responses were revealed. Finally, some suggestions about choosing reagent gas and heater temperature were proposed for types of TCM active substance, which offered a reference for the application of DART-MS on TCM analysis.

  4. Exact relativistic kinetic theory of an electron beam-plasma system: hierarchy of the competing modes in the system parameter space

    CERN Document Server

    Bret, A; Benisti, D; Lefebvre, E

    2008-01-01

    Besides being one of the most fundamental basic issues of plasma physics, the stability analysis of an electron beam-plasma system is of critical relevance in many areas of physics. Surprisingly, decades of extensive investigation had not yet resulted in a realistic unified picture of the multidimensional unstable spectrum within a fully relativistic and kinetic framework. All attempts made so far in this direction were indeed restricted to simplistic distribution functions and/or did not aim at a complete mapping of the beam-plasma parameter space. The present paper comprehensively tackles this problem by implementing an exact linear model. We show that three kinds of modes compete in the linear phase, which can be classified according to the direction of their wavenumber with respect to the beam. We then determine their respective domain of preponderance in a three-dimensional parameter space. All these results are supported by multidimensional particle-in-cell simulations.

  5. Optimal conditions and operational parameters for conversion of Robusta coffee residues in a continuous stirred tank reactor

    Energy Technology Data Exchange (ETDEWEB)

    Msambichaka, B.L.; Kivaisi, A.K.; Rubindamayugi, M.S.T. [Univ. of Dar es Salaam, Applied Microbiology Unit (Tanzania, United Republic of)

    1997-12-31

    This experiment studied the possibility of optimizing anaerobic degradation, developing microbial adaptation and establishing long term process stability in a Continuous Stirred Tank Reactor (CSTR) running on Robusta coffee hulls as feed substrate. Decrease in lag phase and increase in methane production rate in batch culture experiment conducted before and after process stabilization of each operational phase in the CSTR clearly suggested that microbial adaptation to increasing coffee percentage composition was attained. Through gradual increase of coffee percentage composition, from 10% coffee, 2% VS, 20 days HRT and a 1 g VS/1/day loading rate to 80% coffee, 4.5% VS, 12 days HRT and a loading rate of 3 g VS/1/day the CSTR system was optimized at a maximum methane yield of 535 ml/g VS. Again it was possible to attain long term process stability at the above mentioned optimal operational parameters for a further 3 month period. (au)

  6. Clinical, hematological, total plasma protein and fibrinogen parameters of magellanic penguins ( Spheniscus magellanicus pre- and post-rehabilitation

    Directory of Open Access Journals (Sweden)

    Angela M. Coraiola

    2014-12-01

    Full Text Available Abstract: Magellanic penguins (Spheniscus magellanicus usually arrive in poor body conditions at Brazilian beaches during the winter. Hematology provides valuable information about clinical and immunity status of the animals. The aims of this study were to determine the hematologic, total plasma protein (TPP and fibrinogen profiles of young and adult magellanic penguins in PROAMAR and CETAS-SC, relating these results with the state of health and survival possibility of the animals. In Paraná 14 animals were evaluated in pre and eight in post-rehabilitation and 29 animals were evaluated in Santa Catarina after rehabilitation. Before rehabilitation, all animals showed weakness. In hematological exams of these animals, we found that anemia was present in 83% of the penguins that died and 50% of those which survived. The heterophils/lymphocytes (H/L ratio was 3.87±0.57 in animals that died, significantly higher than the average of 2.20±0.30 for animals that survived. These two parameters are useful to assess the survival possibility of animals to rehabilitation. The body condition score was positively correlated with hematocrit and TPP, and negatively correlated with H/L ratio. After rehabilitation, the values were similar to other animals of the family Spheniscidae, with averages ranging from 1.64 to 1.90x106 erythrocytes/μL; 43.38 to 48.80% of hematocrit; 12.45 to 13.52g/dL of hemoglobin; 8,684 to 14,011 leukocytes/μL; 4,767 to 8,041 heterophils/μL; 3,215 to 4,951 lymphocytes/μL; 95 to 655 eosinophils/μl; 179.8 to 277.9 monocytes/μL; 141 to 184.9 basophils/μL; and 1.26 to 1.74 of H/L ratio. These parameters can therefore be used as reference values and release parameters for young and adult Magellanic penguins in captivity on the rehabilitation centers.

  7. Demonstration of neutron production in a table-top pinch plasma focus device operating at only tens of joules

    Energy Technology Data Exchange (ETDEWEB)

    Soto, Leopoldo; Silva, Patricio; Moreno, Jose; Zambra, Marcelo; Pavez, Cristian [Comision Chilena de EnergIa Nuclear, Casilla 188-D, Santiago (Chile); Kies, Walter; Altamirano, Luis; Huerta, Luis [Center for Research and Applications in Plasma Physics and Pulsed Power, P4 (Chile); Mayer, Roberto E [Centro Atomico Bariloche and Instituto Balseiro, 8400 Bariloche (Argentina); Clausse, Alejandro [CNEA-CONICET and Universidad Nacional del Centro, 7000 Tandil (Argentina)], E-mail: lsoto@cchen.cl

    2008-10-21

    Neutron emission from a deuterium plasma pinch generated in a very small plasma focus (6 mm anode diameter) operating at only tens of joules is presented. A maximum current of 50 kA is achieved 140 ns after the beginning of the discharge, when the device is charged at 50 J (160 nF capacitor bank, 38 nH, 20-30 kV, 32-72 J). Although the stored energy is very low, the estimated energy density in the plasma and the energy per particle in the plasma are of the same order as in higher energy devices. The dependence of the neutron yield on the filling pressure of deuterium was obtained for discharges with 50 and 67 J stored in the capacitor bank. Neutrons were measured by means of a system based on a {sup 3}He proportional counter in current mode. The average neutron yield for 50 J discharges at 6 mbar was (1.2 {+-} 0.5) x 10{sup 4} neutrons per shot, and (3.6 {+-} 1.6) x 10{sup 4} for 67 J discharges at 9 mbar. The maximum energy of the neutrons was (2.7 {+-} 1.8) MeV. Possible applications related to substance detection and others are discussed.

  8. Evaluation of the operating parameters of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source for elemental mass spectrometry.

    Science.gov (United States)

    Zhang, Lynn X; Manard, Benjamin T; Konegger-Kappel, Stefanie; Kappel, Stefanie Konegger; Marcus, R Kenneth

    2014-11-01

    The liquid sampling-atmospheric pressure glow discharge (LS-APGD) has been assessed as an ionization source for elemental analysis with an interdependent, parametric evaluation regarding sheath/cooling gas flow rate, discharge current, liquid flow rate, and the distance between the plasma and the sampling cone of the mass spectrometer. In order to better understand plasma processes (and different from previous reports), no form of collision/reaction processing was performed to remove molecular interferents. The evaluation was performed employing five test elements: cesium, silver, lead, lanthanum and nickel (10(-4) mol L(-1) in 1 mol L(-1) HNO3). The intensity of the atomic ions, levels of spectral background, the signal-to-background ratios, and the atomic-to-oxide/hydroxide adduct ratios were monitored in order to obtain fundamental understanding with regards to not only how each parameter effects the performance of this LS-APGD source, but also the inter-parametric effects. The results indicate that the discharge current and the liquid sampling flow rates are the key aspects that control the spectral composition. A compromise set of operating conditions was determined: sheath gas flow rate = 0.9 L min(-1), discharge current = 10 mA, solution flow rate = 10 μL min(-1), and sampling distance = 1 cm. Limits of detection (LODs) were calculated using the SBR-RSDB (signal-to-background ratio/relative standard deviation of the background) approach under the optimized condition. The LODs for the test elementals ranged from 15 to 400 ng mL(-1) for 10 μL injections, with absolute mass values from 0.2 to 4 ng.

  9. Influence of the operating parameters and of the sample introduction system on time correlation of line intensities using an axially viewed CCD-based ICP-AES system

    Energy Technology Data Exchange (ETDEWEB)

    Grotti, Marco, E-mail: grotti@chimica.unige.i [Dipartimento di Chimica e Chimica Industriale, Via Dodecaneso 31, 16146 Genova (Italy); Todoli, Jose Luis [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, 03080, Alicante (Spain); Mermet, Jean Michel [Spectroscopy Forever, 01390 Tramoyes (France)

    2010-02-15

    The influence of the acquisition and operating parameters on time correlation between emission line intensities was investigated using axially viewed inductively coupled plasma-multichannel-based emission spectrometry and various sample introduction systems. It was found that to obtain flicker-noise limited signals, necessary to compensate for time-correlated signal fluctuations by internal standardization, the flicker-noise magnitude of the sample introduction system, the integration time and the emission line intensity had to be considered. The highest correlation between lines was observed for ultrasonic nebulization with desolvatation, the noisiest system among those considered, for which the contribution of the uncorrelated shot-noise was negligible. In contrast, for sample introduction systems characterized by lower flicker-noise levels, shot-noise led to high, non-correlated RSD values, making the internal standard method to be much less efficient. To minimize shot-noise, time correlation was improved by increasing the emission line intensities and the integration time. Improvement in repeatability did not depend only on time correlation, but also on the ratio between the relative standard deviations of the analytical and reference lines. The best signal compensation was obtained when RSD values of the reference and analytical lines were similar, which is usually obtained when the system is flicker-noise limited, while departure from similarity can lead to a degradation of repeatability when using the internal standard method. Moreover, the use of so-called robust plasma conditions, i.e. a high power (1500 W) along with a low carrier gas flow rate (0.8 L/min) improved also the compensation. Finally, high correlation and consequent improvement in repeatability by internal standardization was observed also in the presence of complex matrices (sediment and soil samples), although a matrix-induced degradation of the correlation between lines was generally

  10. Real-time Linux operating system for plasma control on FTU--implementation advantages and first experimental results

    Energy Technology Data Exchange (ETDEWEB)

    Vitale, V. E-mail: vitale@frascati.enea.it; Centioli, C.; Iannone, F.; Mazza, G.; Panella, M.; Pangione, L.; Podda, S.; Zaccarian, L

    2004-06-01

    In this paper, we report on the experiment carried out at the Frascati Tokamak Upgrade (FTU) on the porting of the plasma control system (PCS) from a LynxOS architecture to an open source Linux real-time architecture. The old LynxOS system was implemented on a VME/PPC604r embedded controller guaranteeing successful plasma position, density and current control. The new RTAI-Linux operating system has shown to easily adapt to the VME hardware via a VME/INTELx86 embedded controller. The advantages of the new solution versus the old one are not limited to the reduced cost of the new architecture (based on the open-source characteristic of the RTAI architecture) but also enhanced by the response time of the real-time system which, also through an optimization of the real-time code, has been reduced from 150 {mu}s (LynxOS) to 70 {mu}s (RTAI). The new real-time operating system is also shown to be suitable for new extended control activities, whose implementation is also possible based on the reduced duty cycle duration, which leaves space for the real-time implementation of nonlinear control laws. We report here on recent experiments related to the optimization of the coupling between additional radiofrequency power and plasma.

  11. Influence of different operation methods on vertebral body parameters and GH-IGF axis of patients with thoracolumbar bursts fractures

    Institute of Scientific and Technical Information of China (English)

    Qing-Bo Zhu

    2017-01-01

    Objective:To observe the influence situation of different operation methods on the vertebral body parameters and GH-IGF axis of patients with thoracolumbar bursts fractures.Methods:A total of 50 surgical patients with thoracolumbar bursts fractures from February 2014 to January 2016 were selected as the research object, and 50 patients with fractures were divided into two groups by the principle of random allocation, then the group A were treated with surgical treatment by anterior approach, the group B were treated with surgical treatment by posterior approach, then the vertebral body parameters and the serum expression levels of GH-IGF axis indexes of two groups before the surgery and at different time after the surgery were compared.Results: The vertebral body parameters and the serum expression levels of GH-IGF axis indexes of two groups before the surgery were compared (allP>0.05), while the vertebral body parameters and the serum expression levels of GH-IGF axis indexes of two groups at different time after the surgery were all significantly better than those before the surgery, and the results of group B were all better than those of group A (allP<0.05).Conclusions:The influence of surgical treatment by posterior approach for the vertebral body parameters and GH-IGF axis of patients with thoracolumbar bursts fractures are obviously better than those of surgical treatment by anterior approach, so the application value of surgical treatment by posterior approach in the patients with fractures is higher.

  12. Decontamination of a rotating cutting tool during operation by means of atmospheric pressure plasmas

    DEFF Research Database (Denmark)

    Leipold, Frank; Kusano, Yukihiro; Hansen, F.

    2010-01-01

    The decontamination of a rotating cutting tool used for slicing in the meat industry by means of atmospheric pressure plasmas is investigated. The target is Listeria monocytogenes, a bacterium which causes listeriosis and can be found in plants and food. The non-pathogenic species, Listeria innocua...

  13. [Investigation on the electron density of a micro-plasma jet operated at atmospheric pressure].

    Science.gov (United States)

    Li, Xue-chen; Zhao, Na; Liu, Wei-yuan; Liu, Zhi-qiang

    2010-07-01

    In the present paper, a micro-hollow cathode discharge setup was used to generate micro-plasma jet in flowing mixture of Ar and N2 at atmospheric pressure. The characteristics of the micro-plasma jet were investigated by means of optical method and electrical one. It has been found that breakdown occurs in the gas between the two electrodes when the input power of electric source is increased to a certain value. Plasma appears along the gas flow direction when the mixed gas flows from the aperture of the micro-hollow cathode, and the length of plasma reaches 4 mm. The discharge current is quasi-continuous, and the duration of discharge pulse is about 0.1 micros. Electron density was studied by using Einstein equation and Stark broadening of spectral lines from the emission spectrum respectively. It was found that the results of electron density calculated by the two methods are consistent with the order of 10(15) x cm(-3). It was also found that the electron density is almost independent of power. A qualitative explanation to the phenomenon is given based on the gas discharge theory.

  14. Operational Modal Parameter Identification Based on ICA%基于ICA的工作模态参数识别

    Institute of Scientific and Technical Information of China (English)

    张锐; 黄晋英; 郎忠宝

    2015-01-01

    The paper expounds the principle of independent component analysis and the operational modal analysis based on the principle of ICA. The analysis demonstrates the consistency between ICA separation model and structural vibration modal analysis model. The ICA algorithm and the software OMA developed by Belgian LMS are applied to identify the condition of gear box and broken tooth through modal parameters respectively. This paper finds that the algorithm of ICA, comparing with Op.PolyMAX which is the most commonly used, has strong anti-noise performance. Besides, it is easy to operate and the identification is accurate, this kind of algorithm provides a new basis of work modal parameters identification.%本文分别阐述了独立分量分析和基于ICA的工作模态分析原理,发现了ICA分离模型与结构振动模态分析模型的一致性。应用ICA算法和比利时LMS公司的OMA分析软件分别对齿轮箱正常和断齿工况进行模态参数识别,对比发现,ICA算法与目前最常用的Op. PolyMAX算法相比抗噪性强,识别简便精准,为工作模态参数识别提供新的识别依据。

  15. CFD simulations of flow erosion and flow-induced deformation of needle valve: Effects of operation, structure and fluid parameters

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Hongjun, E-mail: ticky863@126.com [State Key Laboratory of Oil and Gas Reservoir Geology and Exploitation, Southwest Petroleum University, Chengdu 610500, Sichuan (China); State Key Laboratory of Hydraulics and Mountain River Engineering, Sichuan University, Chengdu 610065, Sichuan (China); Pan, Qian; Zhang, Wenli; Feng, Guang; Li, Xue [State Key Laboratory of Oil and Gas Reservoir Geology and Exploitation, Southwest Petroleum University, Chengdu 610500, Sichuan (China)

    2014-07-01

    Highlights: • A combined FSI–CFD and DPM computational method is used to investigate flow erosion and deformation of needle valve. • The numerical model is validated with the comparison of measured and predicted erosion rate. • Effects of operation, structure and fluid parameters on flow erosion and flow-induced deformation are discussed. • Particle diameter has the most significant effect on flow erosion. • Inlet rate has the most obvious effect on flow-induced deformation. - Abstract: A three-dimensional fluid–structure interaction (FSI) computational model coupling with a combined continuum and discrete model has been used to predict the flow erosion rate and flow-induced deformation of needle valve. Comparisons with measured data demonstrate good agreement with the predictions of erosion rate. The flow field distribution of gas-particle flow and the erosion rate and deformation of valve core are captured under different operating and structural conditions with different fluid parameters. The effects of inlet velocity, valve opening and inlet valve channel size, particle concentration, particle diameter and particle phase components are discussed in detail. The results indicate that valve tip has the most severe erosion and deformation, and flow field, erosion rate and deformation of valve are all sensitive to inlet condition changes, structural changes and fluid properties changes. The effect of particle diameter on erosion is the most significant, while the influence of inlet rate on deformation is the greatest one.

  16. Chemometrical assessment of the electrical parameters obtained by long-term operating freshwater sediment microbial fuel cells.

    Science.gov (United States)

    Mitov, Mario; Bardarov, Ivo; Mandjukov, Petko; Hubenova, Yolina

    2015-12-01

    The electrical parameters of nine freshwater sediment microbial fuel cells (SMFCs) were monitored for a period of over 20 months. The developed SMFCs, divided into three groups, were started up and continuously operated under different constant loads (100, 510 and 1100 Ω) for 2.5 months. At this stage of the experiment, the highest power density values, reaching 1.2 ± 0.2 mW/m(2), were achieved by the SMFCs loaded with 510 Ω. The maximum power obtained at periodical polarization during the rest period, however, ranged between 26.2 ± 2.8 and 35.3 ± 2.8 mW/m(2), strongly depending on the internal cell resistance. The statistical evaluation of data derived from the polarization curves shows that after 300 days of operation all examined SMFCs reached a steady-state and the system might be assumed as homoscedastic. The estimated values of standard and expanded uncertainties of the electric parameters indicate a high repeatability and reproducibility of the SMFCs' performance. Results obtained in subsequent discharge-recovery cycles reveal the opportunity for practical application of studied SMFCs as autonomous power sources.

  17. Ion beam emission within a low energy focus plasma (0.1 kJ) operating with hydrogen

    Energy Technology Data Exchange (ETDEWEB)

    El-Aragi, Gamal E. [Nuclear Research Center, Cairo (Egypt). Plasma Physics and Nuclear Fusion Dept.

    2010-06-15

    An investigation of energetic ion beam emission from a low energy plasma focus (0.1 kJ Mather type) device operating with hydrogen gas is studied. The ion beam emission is investigated using time-integrated and time-resolved detectors. The present plasma focus device is powered by a capacitor bank of 1 {mu}F at 18 kV maximum charging voltage. The correlation of ion beam intensity with filling gas pressure indicates that the beam emission is maximized at the optimum pressure for the focus formation at peak current. Energy of ions is determined with a time-of-flight (TOF) method, taking into account distance from the center electrode to the detection plane. (orig.)

  18. Sublethal Effects of Paraquat on Some Plasma Organic Constituents (Metabolic Parameters of African Catfish: Clarias gariepinus (Osteichthys-Clariidae

    Directory of Open Access Journals (Sweden)

    Okenabirhie Jennifer

    2007-01-01

    Full Text Available The plasma levels of glucose, protein, cholesterol and triglyceride were determined in Clarias gariepinus exposed to sublethal concentrations of paraquat (0.30 and 0.15 mg L-1. There were significant decrease (p<0.05 in plasma glucose (showing hypoglycemia situation, plasma protein and triglyceride with a significant increase (p<0.050 in plasma cholesterol when compared with the control. These changes were directly proportional to the toxicant concentration and the exposure periods thus it is dose dependent and time-dependent.

  19. Effect of high-power laser divergence on the plasma structural parameters during multiple filamentation in air

    Science.gov (United States)

    Geints, Yu. E.; Zemlyanov, A. A.

    2016-06-01

    Multiple filamentation of an infrared high-power laser pulse in air is considered. Based on the numerical solution to the unidirectional pulse propagation equation, the effect of radiation external focusing on the spatial structure of the plasma area produced in the filamentation region is studied. We show that the number of generated plasma channels in the beam wake and the density of their spatial distribution over the filamentation region depend on the initial divergence of laser radiation. We found that in a specific range of beam focusing the number of produced plasma channels could be minimized due to the formation of a consolidated thick plasma bunch at the beam axis.

  20. Influence of the operating parameters on the flux during microfiltration of the steepwater in the starch industry

    Directory of Open Access Journals (Sweden)

    Šereš Zita I.

    2012-01-01

    Full Text Available The subject of the work is the possibility of applying microfiltration through a ceramic tubular membrane with 100 nm pore sizes to the steepwater obtained in the production process of corn starch. The dry matter content should be reduced in the steepwater permeate. Thus the consumption of the process water would be reduced, the nutrients from the steepwater could be exploited as feed and the wastewater problem would consequently be solved. The objective of the work was to examine the influence of the operating parameters on the permeate flux during steepwater microfiltration. The parameters that vary in the course of microfiltration, were the transmembrane pressur and flow rate, while the permeate flux and dry matter content of the permeate and retentate were the dependent parameters, constantly monitored during the process. Another objective of this study was to investigate the influence of static turbulence promoter on the permeate flux during steepwater microfiltration. Static mixers enhance permeate flux, thus the microfiltration can be performed longer. As a result of the statistical analysis, the optimal conditions for steepwater microfiltration were determined. The maximum value of the permeate flux without mixer (25 lm-2h-1 was achieved at a pressure of 2 bars and a flow rate around 100 lh-1. With the use of static mixer the flux is 2,5 times higher compared to the one obtained without the mixer. The dry matter content of the permeat after 2.5 hours of mucrofiltration was lowered by 40%.